CRHE-H

TECHNICAL DATA

VENTILATION UNIT WITH HEAT RECOVERY FOR COMMERCIAL AND INDUSTRIAL BUILDINGS

indoor air quality and energy saving

CRHE-HNon-residential ventilator unit with dual flow and high yield heat recovery.

PERFORMANCEEquipped with counter current heat exchanger in aluminium (Eurovent certified) and electronic backward blade ventilators. The total bypass as standard allows favourable climatic conditions to be taken advantage of outside the building for free cooling (or free heating) in automatic mode.

STRUCTURECRHE-H is manufactured using a profiled extruded aluminium frame and 25 mm thick sandwich panels, insulated in polyurethane foam. The panels and inner parts are manufactured in Aluzinc, material that ensures high strength against corrosion and oxidation. A panel with shutter opening eases access to the filters (F7 for the renewed air flow and G4 for the extraction air flow). CRHE H is prepared for installation outdoors (with an optional, specific protective roof) and indoors. Available in 4 sizes, it can be equipped with air post-treat-ment systems (inside the unit) such as: hot/cold water battery, electrical heater or direct expansion battery. CRHE-H was designed to enable easy configuration of the connection to the air distribu-tion/captation ducts. It is also possible and easy to install post-air treatment devices after sale.

CONTROLSCRHE H was supplied with an electric box and control system; it is available in a version equipped with EVO-PH control and a version equipped with EVOD-PH-IP control prepared for complete integra-tion in home automation systems (Modbus protocol with Ethernet connection or, on request, with the addition of connection RS485). The new version of our control systems enables extremely easy and rapid passage from a control system to another, even after installa-tion with the single replacement of the remote panel.

The EVO-PH control has a coloured, backlit touch screen interface with intuitive viewing of the working status of the machine. It enables precise adjustment of ventilator speed and has a weekly , time schedule for automatic management of the ventilators. It can be controlled by an external switch to activate the booster function, it can automatically adjust the air flow rate if connected to an air quality probe, it can manage any air post treatment accessories, it automatically manages the bypass and prevents heat exchanger freezing by managing the speed of the ventilators or, if installed, an electrical pre-heating resistor (optional accessory outside the machine); it signals to the user the need to replace the filters (the clogging status of the filters is monitored by a pair of different pressu-re switches, supplied as standard) or an anomaly, indicating the origin. With the addition of optional accessories (COP kit and CAV kit installed on the channel) you can manage the ventilation machi-ne in constant pressure or constant flow rate mode.

The EVOD-PH-IP control has the same characteristics as the EVO-PH version with the addition of Modbus communication protocol which allows full control of the machine by the supervision software of the home automation system. The implemented webserver allows interaction with the machine, even with an internet browser of a device connected (even from remote) to the home automation system in which the machine is inserted.

ACCESSORIESCRHE-H can be equipped with other accessories such as:. R.H. of probe, CO2 or CO2 / VOC. Operating kit pressure or constant flow. protection roof for outside installalzione. grilles and damper

For a more complete view of the characteristics of the control panels, please read the specific manuals

2

®

expulsion air

fresh air

supply air

exhaust air

expulsion air

fresh air

supply air

exhaust air

CRHE-H (horizontal) - TOP VIEW

Standard version

Mirrored version

Counterflow heat exchanger made of aluminum manufactured by RECUTECHRECUTECH participates in the Eurovent Certification Program

PERFORMANCE (UNI EN 13141-7)

The unit must be ducted properly: UTEK authorizes the use only according to its performance diagram shown into this catalogueThe declared performances are with CLEAN filters, and guaranteed ONLY with the original filters UTEK low pressure drop.

3

0,00 0,05 0,10 0,15 0,20 0,25 0,30

0

50

100

150

200

250

300

350

400

0

100

200

300

400

500

600

700

0 200 400 600 800 1000 1200

Air flow [m3/s]

Po

we

r [W

]

Pre

ssu

re [

Pa

]

Air flow [m3/h]

0,00 0,02 0,04 0,06 0,08 0,10 0,12 0,14 0,16 0,18

0

50

100

150

200

250

300

350

0

100

200

300

400

500

600

0 100 200 300 400 500 600 700

Air flow [m3/s]

Po

we

r [W

]

Pre

ssu

re [

Pa

]

Air flow [m3/h]

CRHE-H 700

CRHE-H 1100

Max MIn Max Min

Pressure Power

Max MIn Max Min

Pressure Power

Min

Min

Max

Max

Min

Min

Max

Max

PERFORMANCE (UNI EN 13141-7)

The unit must be ducted properly: UTEK authorizes the use only according to its performance diagram shown into this catalogueThe declared performances are with CLEAN filters, and guaranteed ONLY with the original filters UTEK low pressure drop.

4

0,0 0,1 0,2 0,3 0,4 0,5 0,6 0,7 0,8 0,9

0

200

400

600

800

1000

1200

1400

0

200

400

600

800

1000

0 500 1000 1500 2000 2500 3000 3500

Air flow [m3/s]

Pow

er [

W]

Pre

ssu

re [

Pa]

Air flow [m3/h]

0,00 0,10 0,20 0,30 0,40 0,50 0,60

0

100

200

300

400

500

600

700

800

900

0

200

400

600

800

1000

1200

0 500 1000 1500 2000 2500

Air flow [m3/s]

Po

we

r [W

]

Pre

ssu

re [

Pa

]

Air flow [m3/h]

CRHE-H 2300

CRHE-H 3400

Max MIn Max Min

Pressure Power

Max MIn Max Min

Pressure Power

Min

Min

Max

Max

Min

Min

Max

Max

0,0 0,1 0,2 0,3 0,4 0,5 0,6 0,7 0,8 0,9

80%

82%

84%

86%

88%

90%

92%

94%

96%

98%

100%

0 500 1000 1500 2000 2500 3000 3500

Air flow [m3/h]

Effic

ien

cy

[%

]

Air flow[m3/h]

CRHE 1100 H CRHE 2300 H CRHE 3400 H

Values refered to the following conditions (UNI EN 13141-7): Tbs external air 5°C; U.R. esternal 72%; Tbs enviorment 25°C; U.R. enviorment 28%

5

HEAT RECOVERY PERFORMANCE (sensible efficiency)

D1 (M) L3 (M) F7 (M) T4 (M) TB3 (M)

D1 (M) L3 (M) F7 (M) T4 (M) TB3 (M)D1 (M) L3 (M) F7 (M) T4 (M) TB3 (M)

D1 (M) L3 (M) F7 (M) T4 (M) TB3 (M)

CRHE-H 700

CRHE-H 1100

CRHE-H 2300

CRHE-H 3400

VALUES ACCORDING UNI EN 1886: 2008

UNIT CASING LEAKAGE

FILTER CLASS

THERMAL TRANSMITTANCE THERMAL BRIDGECASING

STRENGTH

CRHE 700 H

700

1100

2300 3400

CRHE-H 700

CRHE-H 1100

CRHE-H 2300

80,0 200 1079 1407 1137 1,87 511 54,4

84,0 200 529 1511 1241 1,62 296 58,7

81,8 200 753 1401 1131 2,04 498 60,8

81,7

0,15

0,25 0,55

0,81 200

0,32

0,350,83

1,27 664 1358 1088 1,97 349 49,7

11,2

4,4

4,7

3,1

5,7

4,2

3,2

2,6

* Compared to �nom

CRHE-H 3400

MOD. �nom [m³/s]

∆рs,int[Pa]

SFPint [W/(m³/s)] [W/(m³/s)]

SFPint_lim 2016 [W/(m³/s)]

SFPint_lim 2018 ɳt_nvru [%]

ɳFan [%]

FACEVELOCITY[m/s]

* Internal LEAKAGE

[%]

* External LEAKAGE

[%]

∆рs,ext[Pa] P [kW]

ECODESIGN

NOISE LEVEL

TEST LEAKAGE (UNI EN 13141-7)

Lw Sound power level taken in accordance to UNI EN ISO 3747 - CLASS 3

6

ELECTRICAL DATA

CRHE-H 700 230V 50/60 Hz 1F 230V 50 Hz 1F2 x 1,20 2,50 IP54 CLASS B

FANS

2 x 145

CRHE-H 1100 230V 50/60 Hz 1F 230V 50 Hz 1F2 x 1,40 2,90 IP54 CLASS B 2 x 170

Power [W] Supply Supply Current max.[A] Current max.[A] Insulation class UNIT CRHE-HMATCHING

CRHE-H 2300 230V 50/60 Hz 1F 230V 50 Hz 1F2 x 2,80 5,70 IP54 CLASS B 2 x 448

CRHE-H 3400 230V 50/60 Hz 1F 230V 50 Hz 1F2 x 3,10 6,30

IP 20

IP 20

Insulation class

IP 20

IP 20IP54 CLASS B 2 x 715

OUTDOOR

INDOOR

OUTDOOR

A2

A2

CONDIZIONI DI PROVA

LEAKAGE CLASSIFICATION

CRHE-H 700 CRHE-H 1100 CRHE-H 2300 CRHE-H 3400

Negative pressure 400 Pa

Pressure difference 250 Pa

Positive pressure 400 Pa A2

A2

A2

A2A1

A2

A2

A2

A3

A2

LEAKAGE

NOISE IN THE DUCTS (dB)

NOISE FROM THE CASE (dB)CRHE-H 700

CRHE-H 700

125 Hz 250 Hz 500 Hz 1000 Hz 2000 Hz

4000 Hz

67 68 54 53 51 47 45 61,9

66 66 55 46 41 33 31 59,6

8000 Hz

L dB(A)w

125 Hz 250 Hz 500 Hz 1000 Hz 2000 Hz

4000 Hz 8000 Hz L dB(A)w

NOISE FROM THE CASE (dB)

125 Hz 250 Hz 500 Hz 1000 Hz 2000 Hz

4000 Hz

8000 Hz L dB(A)w

NOISE IN THE DUCTS (dB)

125 Hz 250 Hz 500 Hz 1000 Hz 2000 Hz

4000 Hz 8000 Hz L dB(A)

w

NOISE FROM THE CASE (dB)

125 Hz 250 Hz 500 Hz 1000 Hz 2000 Hz

4000 Hz 8000 Hz L dB(A)

w

CRHE-H 1100

CRHE-H 1100

CRHE-H 2300

67 74 60 57 52 44 34 66,8

NOISE IN THE DUCTS (dB)

125 Hz 250 Hz 500 Hz 1000 Hz 2000 Hz

4000 Hz 8000 Hz L dB(A)

w

CRHE-H 2300

NOISE FROM THE CASE (dB)

125 Hz 250 Hz 500 Hz 1000 Hz 2000 Hz

4000 Hz 8000 Hz L dB(A)

w

CRHE-H 3400

69 76 57 59 50 43 35 68,6

NOISE IN THE DUCTS (dB)

125 Hz 250 Hz 500 Hz 1000 Hz 2000 Hz

4000 Hz 8000 Hz L dB(A)

w

CRHE-H 3400

58 59 46 41 35 30 22 51,8

72 67 58 47 45 37 32 61,6

69 77 61 60 55 48 39 69,3

76 78 60 61 56 51 43 70,9

7

DIMENSIONS (mm) WEIGHT (kg)

INSTALLATION CRHE-H

FLOOR INSTALLATION

A B

C

D

==

Ø 1/2" gasØ

Access side forinspection of the ventilators

Extraordinary maintenance and Replacing ofwater coil and

Electric heater

A

UNIT Dimensions [mm]

B C D ØØCRHE-H 700 1590 740 360 200 200

CRHE-H 1100 1815 1240 420 225 250CRHE-H 2300 2180 1640 495 295 355CRHE-H 3400 2400 1740 635 450 450

103149280352

Weight

C

A

BD

Access side for post-heating devices

A B C ECRHE-H 700 660 600 360 340CRHE-H 1100 720 600 420 400CRHE-H 2300 820 800 495 530CRHE-H 3400 980 850 635 560

A B C DCRHE-H 700 250 700 250 370CRHE-H 1100 250 1200 250 430CRHE-H 2300 250 1600 320 560CRHE-H 3400 250 1700 320 590

A ( 1 : 14 )

B

A

E

E

C

C E

350 min.

350 min.

350 min.

(mm)Minimum required space for maintenance

UNIT Dimensions [mm] UNIT Dimensions [mm]

CEILING INSTALLATION

8

Extraordinary maintenance and Replacing ofwater coil and

Electric heater

A B C ECRHE-H 700 660 600 360 340CRHE-H 1100 720 600 420 400CRHE-H 2300 820 800 495 530CRHE-H 3400 980 850 635 560

A B C DCRHE-H 700 250 700 250 370CRHE-H 1100 250 1200 250 430CRHE-H 2300 250 1600 320 560CRHE-H 3400 250 1700 320 590

B ( 1 : 10 )B

B

C

E

A

E

E

C

350 min.

A

B

C

D

350 min.

350 min.

A

(mm)Minimum required space for maintenance

STANDARD SIPHON [mm]

UNIT Dimensions [mm] UNIT Dimensions [mm]

185,0

95,0

�32

,0

�26

,0185

95

Ø 2

6

Ø 3

2

COILS CRHE-H 700

Cooling water coil (7°C/12°C)

Water flow volume

Potenza

9

41 kW

37 kW

34 kW

1,7 2,0 2,3

0

2

4

6

8

10

6000 7000 8000

Portata aria [m3/s]

Perd

ita la

to a

ria [P

a]

Portata aria [m3/h]

Tin 10°C Tin 15°C Air pressure drop

Outlet temperature

Water pressure drop

0,8 1,1 1,4 1,7 2,0 2,3

0

4

8

12

16

0

1

2

3

4

3000 4000 5000 6000 7000 8000

Portata aria [m 3/s]

Perd

ita la

to a

cq

ua [k

Pa]

Porta

ta a

cq

ua [m

3 /h]

Portata aria [m 3/h]

Tin 5°C Tin 10°C Tin 15°C

Tin 25°C Tin 30°C Tin 32°C

1/2” 2 2,5 1 Cu Al Fe Zn

INT.VOL. [dm³] TUBES FINS FRAME N. ROWS Ø WATER [”gas] FIN PITCH [mm]

MATERIALS

1/2” 2 2,5 1 Cu Al Fe Zn

INT.VOL. [dm³] TUBES FINS FRAME N. ROWS Ø WATER [”gas] FIN PITCH [mm]

MATERIALS

Heating water coil (45°C/35°C)

41 kW

37 kW

34 kW

1,7 2,0 2,3

0

2

4

6

8

10

6000 7000 8000

Portata aria [m3/s]

Perd

ita la

to a

ria [P

a]

Portata aria [m3/h]

Tin 10°C Tin 15°C Air pressure drop

0,8 1,1 1,4 1,7 2,0 2,3

0

4

8

12

16

0

1

2

3

4

3000 4000 5000 6000 7000 8000

Portata aria [m 3/s]

Perd

ita la

to a

cq

ua [k

Pa]

Porta

ta a

cq

ua [m

3 /h]

Portata aria [m 3/h]

Tin 25°C Tin 30°C Tin 32°C

Tin 5°C Tin 10°C Tin 15°C

41 kW

37 kW

34 kW

1,1 1,4 1,7 2,0 2,3

0

2

4

6

8

10

4000 5000 6000 7000 8000

Portata aria [m3/s]

Perd

ita la

to a

ria [P

a]

Portata aria [m3/h]

Tin 25°C Tin 30°C Tin 32°C Perdita lato aria

41 kW

37 kW

34 kW

1,1 1,4 1,7 2,0 2,3

0

2

4

6

8

10

4000 5000 6000 7000 8000

Portata aria [m3/s]

Perd

ita la

to a

ria [P

a]

Portata aria [m3/h]

Tin 5°C Tin 10°C Tin 15°C Perdita lato aria

Potenza

Water pressure drop

0,8 1,1 1,4 1,7 2,0 2,3

0

4

8

12

16

0

1

2

3

4

3000 4000 5000 6000 7000 8000

Portata aria [m 3/s]

Perd

ita la

to a

cq

ua [k

Pa]

Porta

ta a

cq

ua [m

3 /h]

Portata aria [m 3/h]

Tin 5°C Tin 10°C Tin 15°C

Tin 5°C Tin 10°C Tin 15°C

Water flow volume

0,8 1,1 1,4 1,7 2,0 2,3

0

4

8

12

16

0

1

2

3

4

3000 4000 5000 6000 7000 8000

Portata aria [m 3/s]

Perd

ita la

to a

cq

ua [k

Pa]

Porta

ta a

cq

ua [m

3 /h]

Portata aria [m 3/h]

Tin 5°C Tin 10°C Tin 15°C

Tin 5°C Tin 10°C Tin 15°C

Outlet temperature

1,6 kW

2,5 kW

3 kW

0,04 0,06 0,08 0,10 0,12 0,14 0,16

0

10

20

30

40

50

10

12

14

16

18

20

22

24

150 250 350 450 550 650

Air flow [m³/s]

Air

pre

ssur

e d

rop

[Pa

]

Tout

[°C

]

Air flow [m³/h]

0,04 0,06 0,08 0,10 0,12 0,14 0,16

0

2

4

6

8

10

0

0,1

0,2

0,3

0,4

0,5

0,6

150 250 350 450 550 650

Air flow [m 3/s]

Wa

ter p

ress

ure

dro

p [k

Pa]

W

ate

r flo

w [l

/h]

x100

0

Air flow [m3/h]

3,7 kW

3,1 kW

2,5 kW

0,04 0,06 0,08 0,10 0,12 0,14 0,16

0

5

10

15

20

25

30

35

40

20

25

30

35

150 250 350 450 550 650

Air flow [m3/s]

Air

pre

ssur

e d

rop

[Pa

]

Tout

[°C

]

Air flow [m3/h]

0,04 0,06 0,08 0,10 0,12 0,14 0,16

0,8

1

1,2

1,4

0

0,1

0,2

0,3

150 250 350 450 550 650

Air flow [m3/s]

Wa

ter p

ress

ure

dro

p [k

Pa]

W

ate

r flo

w [l

/h]

Air flow [m3/h]

0,8 1,1 1,4

15

20

25

30

35

40

3000 4000 5000

Portata aria [m3/s]

Tout

[° C]

Portata aria [m3/h]

Tin 5°C

0,8 1,1 1,4

15

20

25

30

35

40

3000 4000 5000

Portata aria [m3/s]

Tout

[° C]

Portata aria [m3/h]

0,8

15

20

25

30

35

40

3000

Tout

C]

0,8

15

20

25

30

35

40

3000

Tout

C]

32°C

32°C

32°C

25°C25°C

25°C

30°C

30°C

30°C

15°C

5°C

10°C

15°C

15°C

5°C

5°C

10°C

10°C

COILS CRHE-H 1100

Cooling water coil (7°C/12°C)

Water flow volume

Potenza

10

41 kW

37 kW

34 kW

1,7 2,0 2,3

0

2

4

6

8

10

6000 7000 8000

Portata aria [m3/s]

Perd

ita la

to a

ria [P

a]

Portata aria [m3/h]

Tin 10°C Tin 15°C Air pressure drop

Outlet temperature

Water pressure drop

0,8 1,1 1,4 1,7 2,0 2,3

0

4

8

12

16

0

1

2

3

4

3000 4000 5000 6000 7000 8000

Portata aria [m 3/s]

Perd

ita la

to a

cq

ua [k

Pa]

Porta

ta a

cq

ua [m

3 /h]

Portata aria [m 3/h]

Tin 5°C Tin 10°C Tin 15°C

Tin 25°C Tin 30°C Tin 32°C

3/4” 4 2,5 3

3/4” 4 2,5 3

MATERIALS

Heating water coil (45°C/35°C)

41 kW

37 kW

34 kW

1,7 2,0 2,3

0

2

4

6

8

10

6000 7000 8000

Portata aria [m3/s]

Perd

ita la

to a

ria [P

a]

Portata aria [m3/h]

Tin 10°C Tin 15°C Air pressure drop

0,8 1,1 1,4 1,7 2,0 2,3

0

4

8

12

16

0

1

2

3

4

3000 4000 5000 6000 7000 8000

Portata aria [m 3/s]

Perd

ita la

to a

cq

ua [k

Pa]

Porta

ta a

cq

ua [m

3 /h]

Portata aria [m 3/h]

Tin 25°C Tin 30°C Tin 32°C

Tin 5°C Tin 10°C Tin 15°C

41 kW

37 kW

34 kW

1,1 1,4 1,7 2,0 2,3

0

2

4

6

8

10

4000 5000 6000 7000 8000

Portata aria [m3/s]

Perd

ita la

to a

ria [P

a]

Portata aria [m3/h]

Tin 25°C Tin 30°C Tin 32°C Perdita lato aria

41 kW

37 kW

34 kW

1,1 1,4 1,7 2,0 2,3

0

2

4

6

8

10

4000 5000 6000 7000 8000

Portata aria [m3/s]

Perd

ita la

to a

ria [P

a]

Portata aria [m3/h]

Tin 5°C Tin 10°C Tin 15°C Perdita lato aria

Potenza

Water pressure drop

0,8 1,1 1,4 1,7 2,0 2,3

0

4

8

12

16

0

1

2

3

4

3000 4000 5000 6000 7000 8000

Portata aria [m 3/s]

Perd

ita la

to a

cq

ua [k

Pa]

Porta

ta a

cq

ua [m

3 /h]

Portata aria [m 3/h]

Tin 5°C Tin 10°C Tin 15°C

Tin 5°C Tin 10°C Tin 15°C

Water flow volume

0,8 1,1 1,4 1,7 2,0 2,3

0

4

8

12

16

0

1

2

3

4

3000 4000 5000 6000 7000 8000

Portata aria [m 3/s]

Perd

ita la

to a

cq

ua [k

Pa]

Porta

ta a

cq

ua [m

3 /h]

Portata aria [m 3/h]

Tin 5°C Tin 10°C Tin 15°C

Tin 5°C Tin 10°C Tin 15°C

Outlet temperature

7,6 kW

6,4 kW

5,2 kW

0,21 0,23 0,25 0,27 0,29 0,31

0

5

10

15

20

25

30

35

40

22

27

32

750 850 950 1050 1150

Air flow [m³/s]

Air

pre

ssur

e d

rop

[Pa

]

Tout

[°C

]

Air flow [m³/h]

0,21 0,23 0,25 0,27 0,29 0,31

3

3,5

4

4,5

5

5,5

6

0

0,1

0,2

0,3

0,4

0,5

0,6

0,7

750 850 950 1050 1150

Air flow [m3/s]

Wa

ter p

ress

ure

dro

p [k

Pa]

W

ate

r flo

w [l

/h]

Air flow [m3/h]

INT.VOL. [dm³] TUBES FINS FRAME N. ROWS Ø WATER [”gas] FIN PITCH [mm] Cu Al Fe Zn

MATERIALS

INT.VOL. [dm³] TUBES FINS FRAME N. ROWS Ø WATER [”gas] FIN PITCH [mm] Cu Al Fe Zn

0,8 1,1 1,4

15

20

25

30

35

40

3000 4000 5000

Portata aria [m3/s]

Tout

[° C]

Portata aria [m3/h]

0,8 1,1 1,4

15

20

25

30

35

40

3000 4000 5000

Portata aria [m3/s]

Tout

[° C]

Portata aria [m3/h]

0,8

15

20

25

30

35

40

3000

Tout

C]

0,8

15

20

25

30

35

40

3000

Tout

C]

3,2 kW

5,3 kW

6,5 kW

0,21 0,23 0,25 0,27 0,29 0,31

0

10

20

30

40

50

60

70

16

17

18

19

20

21

22

750 850 950 1050 1150

Air flow [m3/s]

Air

pre

ssur

e d

rop

[Pa

]

Tout

[°C

]

Air flow [m3/h]

0,21 0,23 0,25 0,27 0,29 0,31

0

2

4

6

8

10

12

14

16

18

20

22

0

0,2

0,4

0,6

0,8

1

1,2

750 850 950 1050 1150

Air flow [m3/s]

Wa

ter p

ress

ure

dro

p [k

Pa]

Wa

ter f

low

[l/h

]x1

000

Air flow [m3/h]

x100

0

32°C

32°C

32°C

25°C

25°C

25°C

30°C

30°C

30°C

15°C 15°C

15°C

5°C

5°C

5°C

10°C

10°C

10°C

COILS CRHE-H 2300

Cooling water coil (7°C/12°C)

Water flow volume

Potenza

11

41 kW

37 kW

34 kW

1,7 2,0 2,3

0

2

4

6

8

10

6000 7000 8000

Portata aria [m3/s]

Perd

ita la

to a

ria [P

a]

Portata aria [m3/h]

Tin 10°C Tin 15°C Air pressure drop

Outlet temperature

Water pressure drop

0,8 1,1 1,4 1,7 2,0 2,3

0

4

8

12

16

0

1

2

3

4

3000 4000 5000 6000 7000 8000

Portata aria [m 3/s]

Perd

ita la

to a

cq

ua [k

Pa]

Porta

ta a

cq

ua [m

3 /h]

Portata aria [m 3/h]

Tin 5°C Tin 10°C Tin 15°C

Tin 25°C Tin 30°C Tin 32°C

3/4” 4 2,5 5

3/4” 4 2,5 5

Heating water coil (45°C/35°C)

41 kW

37 kW

34 kW

1,7 2,0 2,3

0

2

4

6

8

10

6000 7000 8000

Portata aria [m3/s]

Perd

ita la

to a

ria [P

a]

Portata aria [m3/h]

Tin 10°C Tin 15°C Air pressure drop

0,8 1,1 1,4 1,7 2,0 2,3

0

4

8

12

16

0

1

2

3

4

3000 4000 5000 6000 7000 8000

Portata aria [m 3/s]

Perd

ita la

to a

cq

ua [k

Pa]

Porta

ta a

cq

ua [m

3 /h]

Portata aria [m 3/h]

Tin 25°C Tin 30°C Tin 32°C

Tin 5°C Tin 10°C Tin 15°C

41 kW

37 kW

34 kW

1,1 1,4 1,7 2,0 2,3

0

2

4

6

8

10

4000 5000 6000 7000 8000

Portata aria [m3/s]

Perd

ita la

to a

ria [P

a]

Portata aria [m3/h]

Tin 25°C Tin 30°C Tin 32°C Perdita lato aria

41 kW

37 kW

34 kW

1,1 1,4 1,7 2,0 2,3

0

2

4

6

8

10

4000 5000 6000 7000 8000

Portata aria [m3/s]

Perd

ita la

to a

ria [P

a]

Portata aria [m3/h]

Tin 5°C Tin 10°C Tin 15°C Perdita lato aria

Potenza

Water pressure drop

0,8 1,1 1,4 1,7 2,0 2,3

0

4

8

12

16

0

1

2

3

4

3000 4000 5000 6000 7000 8000

Portata aria [m 3/s]

Perd

ita la

to a

cq

ua [k

Pa]

Porta

ta a

cq

ua [m

3 /h]

Portata aria [m 3/h]

Tin 5°C Tin 10°C Tin 15°C

Tin 5°C Tin 10°C Tin 15°C

Water flow volume

0,8 1,1 1,4 1,7 2,0 2,3

0

4

8

12

16

0

1

2

3

4

3000 4000 5000 6000 7000 8000

Portata aria [m 3/s]

Perd

ita la

to a

cq

ua [k

Pa]

Porta

ta a

cq

ua [m

3 /h]

Portata aria [m 3/h]

Tin 5°C Tin 10°C Tin 15°C

Tin 5°C Tin 10°C Tin 15°C

Outlet temperature

6,6 kW

10,7 kW

13,1 kW

0,44 0,49 0,54 0,59 0,64

0

10

20

30

40

50

60

70

80

15

17

19

21

23

1600 1800 2000 2200 2400

Air flow [m3/s]

Air

pre

ssur

e d

rop

[Pa

]

Tout

[°C

]

Air flow [m3/h]

0,44 0,49 0,54 0,59 0,64

0

2

4

6

8

10

12

14

16

18

20

0,4

0,6

0,8

1

1,2

1,4

1,6

1,8

2

2,2

2,4

1600 1800 2000 2200 2400

Air flow [m3/s]

Wa

ter p

ress

ure

dro

p [k

Pa]

Wa

ter f

low

[l/h

]x1

000

Air flow [m3/h]

15,5 kW

13,1 kW

10,7 kW

0,44 0,49 0,54 0,59 0,64

10

15

20

25

30

35

40

22

27

32

1600 1800 2000 2200 2400

Air flow [m3/s]

Air

pre

ssur

e d

rop

[Pa

]

Tout

[°C

]

Air flow [m3/h]

0,44 0,49 0,54 0,59 0,64

3

3,5

4

4,5

5

5,5

6

0,2

0,4

0,6

0,8

1

1,2

1,4

1600 1800 2000 2200 2400

Air flow [m3/s]

Wa

ter p

ress

ure

dro

p [k

Pa]

Wa

ter f

low

[l/h

]

Air flow [m3/h]

MATERIALS

INT.VOL. [dm³] TUBES FINS FRAME N. ROWS Ø WATER [”gas] FIN PITCH [mm] Cu Al Fe Zn

MATERIALS

INT.VOL. [dm³] TUBES FINS FRAME N. ROWS Ø WATER [”gas] FIN PITCH [mm] Cu Al Fe Zn

0,8 1,1 1,4

15

20

25

30

35

40

3000 4000 5000

Portata aria [m3/s]

Tout

[° C]

Portata aria [m3/h]

Tin 5°C

0,8 1,1 1,4

15

20

25

30

35

40

3000 4000 5000

Portata aria [m3/s]

Tout

[° C]

Portata aria [m3/h]

Tin 5°C

0,8

15

20

25

30

35

40

3000

Tout

C]

0,8

15

20

25

30

35

40

3000 4000

Tout

C]

x100

032°C

32°C

32°C

25°C25°C 25°C

30°C

30°C

30°C

15°C

15°C

15°C

5°C

5°C

5°C 10°C

10°C

10°C

COILS CRHE-H 3400

Cooling water coil (7°C/12°C)

Water flow volume

Potenza

12

41 kW

37 kW

34 kW

1,7 2,0 2,3

0

2

4

6

8

10

6000 7000 8000

Portata aria [m3/s]

Perd

ita la

to a

ria [P

a]

Portata aria [m3/h]

Tin 10°C Tin 15°C Air pressure drop

Outlet temperature

Water pressure drop

0,8 1,1 1,4 1,7 2,0 2,3

0

4

8

12

16

0

1

2

3

4

3000 4000 5000 6000 7000 8000

Portata aria [m 3/s]

Perd

ita la

to a

cq

ua [k

Pa]

Porta

ta a

cq

ua [m

3 /h]

Portata aria [m 3/h]

Tin 5°C Tin 10°C Tin 15°C

Tin 25°C Tin 30°C Tin 32°C

3/4” 2 2,5 5

3/4” 2 2,5 5

Heating water coil (45°C/35°C)

41 kW

37 kW

34 kW

1,7 2,0 2,3

0

2

4

6

8

10

6000 7000 8000

Portata aria [m3/s]

Perd

ita la

to a

ria [P

a]

Portata aria [m3/h]

Tin 10°C Tin 15°C Air pressure drop

0,8 1,1 1,4 1,7 2,0 2,3

0

4

8

12

16

0

1

2

3

4

3000 4000 5000 6000 7000 8000

Portata aria [m 3/s]

Perd

ita la

to a

cq

ua [k

Pa]

Porta

ta a

cq

ua [m

3 /h]

Portata aria [m 3/h]

Tin 25°C Tin 30°C Tin 32°C

Tin 5°C Tin 10°C Tin 15°C

41 kW

37 kW

34 kW

1,1 1,4 1,7 2,0 2,3

0

2

4

6

8

10

4000 5000 6000 7000 8000

Portata aria [m3/s]

Perd

ita la

to a

ria [P

a]

Portata aria [m3/h]

Tin 25°C Tin 30°C Tin 32°C Perdita lato aria

41 kW

37 kW

34 kW

1,1 1,4 1,7 2,0 2,3

0

2

4

6

8

10

4000 5000 6000 7000 8000

Portata aria [m3/s]

Perd

ita la

to a

ria [P

a]

Portata aria [m3/h]

Tin 5°C Tin 10°C Tin 15°C Perdita lato aria

Potenza

Water pressure drop

0,8 1,1 1,4 1,7 2,0 2,3

0

4

8

12

16

0

1

2

3

4

3000 4000 5000 6000 7000 8000

Portata aria [m 3/s]

Perd

ita la

to a

cq

ua [k

Pa]

Porta

ta a

cq

ua [m

3 /h]

Portata aria [m 3/h]

Tin 5°C Tin 10°C Tin 15°C

Tin 5°C Tin 10°C Tin 15°C

Water flow volume

0,8 1,1 1,4 1,7 2,0 2,3

0

4

8

12

16

0

1

2

3

4

3000 4000 5000 6000 7000 8000

Portata aria [m 3/s]

Perd

ita la

to a

cq

ua [k

Pa]

Porta

ta a

cq

ua [m

3 /h]

Portata aria [m 3/h]

Tin 5°C Tin 10°C Tin 15°C

Tin 5°C Tin 10°C Tin 15°C

Outlet temperature

7,8 kW

12,3 kW

14,6 kW

0,50 0,57 0,64 0,71 0,78 0,85 0,92

0

10

20

30

40

50

60

70

16

18

20

22

24

1800 2200 2600 3000 3400

Air flow [m3/s]

Air

pre

ssur

e d

rop

[Pa

]

Tout

[°C

]

Air flow [m3/h]

0,50 0,57 0,64 0,71 0,78 0,85 0,92

0

2

4

6

8

10

12

14

16

18

20

0,4

0,8

1,2

1,6

2

2,4

2,8

1800 2200 2600 3000 3400

Air flow [m3/s]

Wa

ter p

ress

ure

dro

p [k

Pa]

W

ate

r flo

w [l

/h]

x100

0

Air flow [m3/h]

0,50 0,57 0,64 0,71 0,78 0,85 0,92

3

3,5

4

4,5

5

5,5

6

6,5

7

7,5

8

0,2

0,4

0,6

0,8

1

1,2

1,4

1,6

1800 2200 2600 3000 3400

Air flow [m3/s]

Wa

ter p

ress

ure

dro

p [k

Pa]

Wa

ter f

low

[l/h

]

Air flow [m3/h]

MATERIALS

INT.VOL. [dm³] TUBES FINS FRAME N. ROWS Ø WATER [”gas] FIN PITCH [mm] Cu Al Fe Zn

MATERIALS

INT.VOL. [dm³] TUBES FINS FRAME N. ROWS Ø WATER [”gas] FIN PITCH [mm] Cu Al Fe Zn

18,4 kW

15,5 kW

12,6 kW

0,50 0,57 0,64 0,71 0,78 0,85 0,92

10

15

20

25

30

35

40

20

22

24

26

28

30

1800 2200 2600 3000 3400

Air flow [m3/s]

Air

pre

ssur

e d

rop

[Pa

]

Tout

[°C

]

Air flow [m3/h]

x100

032°C

32°C

32°C

25°C

25°C

25°C

30°C

30°C

30°C

15°C

15°C

15°C

5°C

5°C

5°C

10°C 10°C

10°C

13

DX coil CRHE-H 700

500 28 80 5,5 17 100 90

Power [kW] Tout [°C] R.H: out [%] Air pressure drop [Pa]

Air pressure drop [Pa]

Air pressure drop [Pa]

Air pressure drop [Pa]

Tin [C°] Air flow [m³/h] R.H in [%]

22-12 2,5 4 1 5 50

Int.Vol. [dm³] T evap [°C] T cond [°C]Fin pitch [mm]Ø Connection [mm] N. Rows

DIRECT EXPANSION COIL (R410A) TECHNICAL DATA

DX coil CRHE-H 1100

1100 28 68 11 15 98 73

Power [kW] Tout [°C] R.H: out [%]Tin [C°] Air flow [m³/h] R.H in [%]

28-16 2,5 4 3 5 50

Int.Vol. [dm³] T evap [°C] T cond [°C]Fin pitch [mm]Ø Connection [mm] N. Rows

DIRECT EXPANSION COIL (R410A) TECHNICAL DATA

DX coil CRHE-H 2300

2300 28 68 17 18,5 92 49

Power [kW] Tout [°C] R.H: out [%]Tin [C°] Air flow [m³/h] R.H in [%]

28-22 4,0 4 5 5 50

Int.Vol. [dm³] T evap [°C] T cond [°C]Fin pitch [mm]Ø Connection [mm] N. Rows

DIRECT EXPANSION COIL (R410A) TECHNICAL DATA

DX coil CRHE-H 3400

3400 28 68 22 19 90 71

Power [kW] Tout [°C] R.H: out [%]Tin [C°] Air flow [m³/h] R.H in [%]

28-22 4,0 4 6 5 50

Int.Vol. [dm³] T evap [°C] T cond [°C]Fin pitch [mm]Ø Connection [mm] N. Rows

DIRECT EXPANSION COIL (R410A) TECHNICAL DATA

Electrical heater

CRHE-H 700 230V, 50Hz,1F 2 8,7 1

Current [A] N. stages Power supplyUnit Power [kW]

CRHE-H 1100 230V, 50Hz,1F 3 13,0 1

CRHE-H 2300 230V, 50Hz,1F 6 26,0 1

CRHE-H 3400 230V, 50Hz,1F 8 34,7 1

CRHE-H 3400 400V, 50Hz,3F 8 11,5 1

POST ELECTRICAL HEATER TECHNICAL DATA

N.B. – for other batteries PRE or POST treatment see the Techno-list of ACCESSORIES

Informa�on requirements for NRVUs as referred to in Ar�cle 4.2

(Commission Regula�on EU N°1253/2014)

Manufacturer's namea UTEK srl

b Manufacturer's model identifier

c Declared typologyd Type of drive installede Type of HRSfgh

jkl

i

n

o

p

q

rs

Thermal efficiency of heat recoveryNominal NRVU flow rateEffective electric power input

Casing sound power level (LWA)

Internal pressure drop of ventilation componentsNominal external pressure

SFPint

Static efficiency of fans used in accordance with Regulation (EU) No 327/2011

Declared maximum external leakage rate of the casing of ventilation units

Energy performance, preferably energy classification, of the filters (declared information about the calculated annual energy consumption

Position and description of visual filter warning for RVUs intended for use with filters, including text pointing out the importance of regular filter changes for performance and energy efficiency of the unit

Internet address for pre-/dis-assembly instructions

CRHE 700EC BP EVO-PH SH

NRVU / BVUVariable speed drive

Other80.0%

0.146 m³/s0.32 kW

52 dB

511 Pa200 Pa

1080 W/(m³/s)

54.4 %

5.7 %

F7 / G4

Filter warning is signaled on the display of the control system: the flashing writing “DirtyFilters” will

appear.“To preserve the energy efficiency of

the NRVU, it’s recommended to replace the filters when signaled.”

Positioned near the filters inspection.

www.utek.it

Face velocity at design flow rate

m Optional: internal pressure drop of non-ventilation components -

Declared maximum internal leakage rate of bidirectional ventilation units or carry over (for regenerative heat exchangers only)

11.2 %

1.9 m/s

Informa�on requirements for NRVUs as referred to in Ar�cle 4.2

(Commission Regula�on EU N°1253/2014)

Manufacturer's namea UTEK srl

b Manufacturer's model identifier

c Declared typologyd Type of drive installede Type of HRSfgh

jkl

i

n

o

p

q

rs

Thermal efficiency of heat recoveryNominal NRVU flow rateEffective electric power input

Casing sound power level (LWA)

Internal pressure drop of ventilation componentsNominal external pressure

SFPint

Static efficiency of fans used in accordance with Regulation (EU) No 327/2011

Declared maximum external leakage rate of the casing of ventilation units

Energy performance, preferably energy classification, of the filters (declared information about the calculated annual energy consumption

Position and description of visual filter warning for RVUs intended for use with filters, including text pointing out the importance of regular filter changes for performance and energy efficiency of the unit

Internet address for pre-/dis-assembly instructions

CRHE 700EC BP EVO-PH SV

NRVU / BVUVariable speed drive

Other82.2%

0.161 m³/s0.29 kW

52 dB

475 Pa200 Pa

842 W/(m³/s)

56.5 %

5.4 %

F7 / G4

Filter warning is signaled on the display of the control system: the flashing writing “DirtyFilters” will

appear.“To preserve the energy efficiency of

the NRVU, it’s recommended to replace the filters when signaled.”

Positioned near the filters inspection.

www.utek.it

Face velocity at design flow rate

m Optional: internal pressure drop of non-ventilation components -

Declared maximum internal leakage rate of bidirectional ventilation units or carry over (for regenerative heat exchangers only)

9.5 %

1.2 m/s

Informa�on requirements for NRVUs as referred to in Ar�cle 4.2

(Commission Regula�on EU N°1253/2014)

Manufacturer's namea UTEK srl

b Manufacturer's model identifier

c Declared typologyd Type of drive installede Type of HRSfgh

jkl

i

n

o

p

q

rs

Thermal efficiency of heat recoveryNominal NRVU flow rateEffective electric power input

Casing sound power level (LWA)

Internal pressure drop of ventilation componentsNominal external pressure

SFPint

Static efficiency of fans used in accordance with Regulation (EU) No 327/2011

Declared maximum external leakage rate of the casing of ventilation units

Energy performance, preferably energy classification, of the filters (declared information about the calculated annual energy consumption

Position and description of visual filter warning for RVUs intended for use with filters, including text pointing out the importance of regular filter changes for performance and energy efficiency of the unit

Internet address for pre-/dis-assembly instructions

CRHE 1100EC BP EVO-PH SH

NRVU / BVUVariable speed drive

Other84.0%

0.249 m³/s0.35 kW

60 dB

296 Pa200 Pa

529 W/(m³/s)

58.7 %

4.2 %

F7 / G4

Filter warning is signaled on the display of the control system: the flashing writing “DirtyFilters” will

appear.“To preserve the energy efficiency of

the NRVU, it’s recommended to replace the filters when signaled.”

Positioned near the filters inspection.

www.utek.it

Face velocity at design flow rate

m Optional: internal pressure drop of non-ventilation components -

Declared maximum internal leakage rate of bidirectional ventilation units or carry over (for regenerative heat exchangers only)

4.4 %

1.6 m/s

Informa�on requirements for NRVUs as referred to in Ar�cle 4.2

(Commission Regula�on EU N°1253/2014)

Manufacturer's namea UTEK srl

b Manufacturer's model identifier

c Declared typologyd Type of drive installede Type of HRSfgh

jkl

i

n

o

p

q

rs

Thermal efficiency of heat recoveryNominal NRVU flow rateEffective electric power input

Casing sound power level (LWA)

Internal pressure drop of ventilation componentsNominal external pressure

SFPint

Static efficiency of fans used in accordance with Regulation (EU) No 327/2011

Declared maximum external leakage rate of the casing of ventilation units

Energy performance, preferably energy classification, of the filters (declared information about the calculated annual energy consumption

Position and description of visual filter warning for RVUs intended for use with filters, including text pointing out the importance of regular filter changes for performance and energy efficiency of the unit

Internet address for pre-/dis-assembly instructions

CRHE 1100EC BP EVO-PH SV

NRVU / BVUVariable speed drive

Other82.2%

0.254 m³/s0.33 kW

51 dB

278 Pa200 Pa

461 W/(m³/s)

58.5 %

4.6 %

F7 / G4

Filter warning is signaled on the display of the control system: the flashing writing “DirtyFilters” will

appear.“To preserve the energy efficiency of

the NRVU, it’s recommended to replace the filters when signaled.”

Positioned near the filters inspection.

www.utek.it

Face velocity at design flow rate

m Optional: internal pressure drop of non-ventilation components -

Declared maximum internal leakage rate of bidirectional ventilation units or carry over (for regenerative heat exchangers only)

7.1 %

1.3 m/s

Informa�on requirements for NRVUs as referred to in Ar�cle 4.2

(Commission Regula�on EU N°1253/2014)

Manufacturer's namea UTEK srl

b Manufacturer's model identifier

c Declared typologyd Type of drive installede Type of HRSfgh

jkl

i

n

o

p

q

rs

Thermal efficiency of heat recoveryNominal NRVU flow rateEffective electric power input

Casing sound power level (LWA)

Internal pressure drop of ventilation componentsNominal external pressure

SFPint

Static efficiency of fans used in accordance with Regulation (EU) No 327/2011

Declared maximum external leakage rate of the casing of ventilation units

Energy performance, preferably energy classification, of the filters (declared information about the calculated annual energy consumption

Position and description of visual filter warning for RVUs intended for use with filters, including text pointing out the importance of regular filter changes for performance and energy efficiency of the unit

Internet address for pre-/dis-assembly instructions

CRHE 2300EC BP EVO-PH SH

NRVU / BVUVariable speed drive

Other81.8%

0.547 m³/s0.83 kW

67 dB

498 Pa200 Pa

752 W/(m³/s)

60.8 %

3.2 %

F7 / G4

Filter warning is signaled on the display of the control system: the flashing writing “DirtyFilters” will

appear.“To preserve the energy efficiency of

the NRVU, it’s recommended to replace the filters when signaled.”

Positioned near the filters inspection.

www.utek.it

Face velocity at design flow rate

m Optional: internal pressure drop of non-ventilation components -

Declared maximum internal leakage rate of bidirectional ventilation units or carry over (for regenerative heat exchangers only)

4.7 %

2.0 m/s

Informa�on requirements for NRVUs as referred to in Ar�cle 4.2

(Commission Regula�on EU N°1253/2014)

Manufacturer's namea UTEK srl

b Manufacturer's model identifier

c Declared typologyd Type of drive installede Type of HRSfgh

jkl

i

n

o

p

q

rs

Thermal efficiency of heat recoveryNominal NRVU flow rateEffective electric power input

Casing sound power level (LWA)

Internal pressure drop of ventilation componentsNominal external pressure

SFPint

Static efficiency of fans used in accordance with Regulation (EU) No 327/2011

Declared maximum external leakage rate of the casing of ventilation units

Energy performance, preferably energy classification, of the filters (declared information about the calculated annual energy consumption

Position and description of visual filter warning for RVUs intended for use with filters, including text pointing out the importance of regular filter changes for performance and energy efficiency of the unit

Internet address for pre-/dis-assembly instructions

CRHE 2500EC BP EVO-PH SV

NRVU / BVUVariable speed drive

Other84.6%

0.597 m³/s0.82 kW

60 dB

344 Pa200 Pa

569 W/(m³/s)

55.4 %

4.0 %

F7 / G4

Filter warning is signaled on the display of the control system: the flashing writing “DirtyFilters” will

appear.“To preserve the energy efficiency of

the NRVU, it’s recommended to replace the filters when signaled.”

Positioned near the filters inspection.

www.utek.it

Face velocity at design flow rate

m Optional: internal pressure drop of non-ventilation components -

Declared maximum internal leakage rate of bidirectional ventilation units or carry over (for regenerative heat exchangers only)

4.6 %

1.5 m/s

Informa�on requirements for NRVUs as referred to in Ar�cle 4.2

(Commission Regula�on EU N°1253/2014)

Manufacturer's namea UTEK srl

b Manufacturer's model identifier

c Declared typologyd Type of drive installede Type of HRSfgh

jkl

i

n

o

p

q

rs

Thermal efficiency of heat recoveryNominal NRVU flow rateEffective electric power input

Casing sound power level (LWA)

Internal pressure drop of ventilation componentsNominal external pressure

SFPint

Static efficiency of fans used in accordance with Regulation (EU) No 327/2011

Declared maximum external leakage rate of the casing of ventilation units

Energy performance, preferably energy classification, of the filters (declared information about the calculated annual energy consumption

Position and description of visual filter warning for RVUs intended for use with filters, including text pointing out the importance of regular filter changes for performance and energy efficiency of the unit

Internet address for pre-/dis-assembly instructions

CRHE 3400EC BP EVO-PH SH

NRVU / BVUVariable speed drive

Other81.7%

0.812 m³/s1.27 kW

69 dB

349 Pa200 Pa

662 W/(m³/s)

49.7 %

2.6 %

F7 / G4

Filter warning is signaled on the display of the control system: the flashing writing “DirtyFilters” will

appear.“To preserve the energy efficiency of

the NRVU, it’s recommended to replace the filters when signaled.”

Positioned near the filters inspection.

www.utek.it

Face velocity at design flow rate

m Optional: internal pressure drop of non-ventilation components -

Declared maximum internal leakage rate of bidirectional ventilation units or carry over (for regenerative heat exchangers only)

3.1 %

2.0 m/s

Informa�on requirements for NRVUs as referred to in Ar�cle 4.2

(Commission Regula�on EU N°1253/2014)

Manufacturer's namea UTEK srl

b Manufacturer's model identifier

c Declared typologyd Type of drive installede Type of HRSfgh

jkl

i

n

o

p

q

rs

Thermal efficiency of heat recoveryNominal NRVU flow rateEffective electric power input

Casing sound power level (LWA)

Internal pressure drop of ventilation componentsNominal external pressure

SFPint

Static efficiency of fans used in accordance with Regulation (EU) No 327/2011

Declared maximum external leakage rate of the casing of ventilation units

Energy performance, preferably energy classification, of the filters (declared information about the calculated annual energy consumption

Position and description of visual filter warning for RVUs intended for use with filters, including text pointing out the importance of regular filter changes for performance and energy efficiency of the unit

Internet address for pre-/dis-assembly instructions

CRHE 3200EC BP EVO-PH SV

NRVU / BVUVariable speed drive

Other85.0%

0.825 m³/s1.47 kW

63 dB

299 Pa200 Pa

695 W/(m³/s)

48.3 %

4.2 %

F7 / G4

Filter warning is signaled on the display of the control system: the flashing writing “DirtyFilters” will

appear.“To preserve the energy efficiency of

the NRVU, it’s recommended to replace the filters when signaled.”

Positioned near the filters inspection.

www.utek.it

Face velocity at design flow rate

m Optional: internal pressure drop of non-ventilation components -

Declared maximum internal leakage rate of bidirectional ventilation units or carry over (for regenerative heat exchangers only)

3.5 %

1.5 m/s

Informa�on requirements for NRVUs as referred to in Ar�cle 4.2

(Commission Regula�on EU N°1253/2014)

Manufacturer's namea UTEK srl

b Manufacturer's model identifier

c Declared typologyd Type of drive installede Type of HRSfgh

jkl

i

n

o

p

q

rs

Thermal efficiency of heat recoveryNominal NRVU flow rateEffective electric power input

Casing sound power level (LWA)

Internal pressure drop of ventilation componentsNominal external pressure

SFPint

Static efficiency of fans used in accordance with Regulation (EU) No 327/2011

Declared maximum external leakage rate of the casing of ventilation units

Energy performance, preferably energy classification, of the filters (declared information about the calculated annual energy consumption

Position and description of visual filter warning for RVUs intended for use with filters, including text pointing out the importance of regular filter changes for performance and energy efficiency of the unit

Internet address for pre-/dis-assembly instructions

CRHE 4500EC BP EVO-PH SV

NRVU / BVUVariable speed drive

Other84.9%

1.129 m³/s2.59 kW

68 dB

480 Pa250 Pa

1040 W/(m³/s)

51.4 %

3.6 %

F7 / G4

Filter warning is signaled on the display of the control system: the flashing writing “DirtyFilters” will

appear.“To preserve the energy efficiency of

the NRVU, it’s recommended to replace the filters when signaled.”

Positioned near the filters inspection.

www.utek.it

Face velocity at design flow rate

m Optional: internal pressure drop of non-ventilation components -

Declared maximum internal leakage rate of bidirectional ventilation units or carry over (for regenerative heat exchangers only)

2.8 %

2.0 m/s

Informa�on requirements for NRVUs as referred to in Ar�cle 4.2

(Commission Regula�on EU N°1253/2014)

Manufacturer's namea UTEK srl

b Manufacturer's model identifier

c Declared typologyd Type of drive installede Type of HRSfgh

jkl

i

n

o

p

q

rs

Thermal efficiency of heat recoveryNominal NRVU flow rateEffective electric power input

Casing sound power level (LWA)

Internal pressure drop of ventilation componentsNominal external pressure

SFPint

Static efficiency of fans used in accordance with Regulation (EU) No 327/2011

Declared maximum external leakage rate of the casing of ventilation units

Energy performance, preferably energy classification, of the filters (declared information about the calculated annual energy consumption

Position and description of visual filter warning for RVUs intended for use with filters, including text pointing out the importance of regular filter changes for performance and energy efficiency of the unit

Internet address for pre-/dis-assembly instructions

CRHE 5600EC BP EVO-PH SV

NRVU / BVUVariable speed drive

Other85.6%

1.453 m³/s2.88 kW

73 dB

370 Pa250 Pa

781 W/(m³/s)

54.0 %

3.0 %

F7 / G4

Filter warning is signaled on the display of the control system: the flashing writing “DirtyFilters” will

appear.“To preserve the energy efficiency of

the NRVU, it’s recommended to replace the filters when signaled.”

Positioned near the filters inspection.

www.utek.it

Face velocity at design flow rate

m Optional: internal pressure drop of non-ventilation components -

Declared maximum internal leakage rate of bidirectional ventilation units or carry over (for regenerative heat exchangers only)

2.3 %

1.8 m/s

Dear Customer

Thanks for your attention to the product UTEK , designedand manufactured to ensure the real values to the User :Quality, Safety and Savings on working. UTEK S.r.l.

the Dealer

UTEK

rese

rves

the

right

to a

t any

tim

e th

e ne

cess

ary

chan

ges t

o im

prov

e pr

oduc

ts w

ithou

t prio

r not

ice

.

UTEK S.r.l. Via Provinciale,30 23030 Mazzo di Valtellina (So) Italy | Tel.+39 0342 862031 | Fax +39 0342 862029 | www.utek-air.it | [email protected]

CRHE-H_2016_2_EN

Made in italy