Alcatel-Lucent GSM
Create Extended Cells
BTS Document
Reconfiguration Method
Release B10
3BK 17430 0845 RJZZA Ed.05
8/4/2019 Create Extended Cell
2/32
Status RELEASED
Short title MPI84 / MDR5
All rights reserved. Passing on and copying of this document, useand communication of its contents not permitted without writtenauthorization from Alcatel-Lucent.
BLANK PAGE BREAK
2 / 32 3BK 17430 0845 RJZZA Ed.05
8/4/2019 Create Extended Cell
3/32
Contents
Contents
Preface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
1 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
1.1 Presentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101.1.1 Cases . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101.1.2 Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101.1.3 Restrictions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101.1.4 Grouped Task Sequence . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
1.2 Preparation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 121.2.1 Prerequisites . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 121.2.2 Site Specific Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 121.2.3 External Tasks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
1.3 Scheduling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 131.4 Telecom/Supervision Outage and Operating Impact . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 151.5 Resources . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
1.5.1 Tools . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
1.5.2 Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 161.5.3 Applicable Documents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
2 Scenario . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
2.1 Before Going Onsite . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 182.2 Before You Start . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
2.2.1 Checks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 192.2.2 Required Knowledge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
2.3 Scenario Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 202.3.1 Initial Checks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 202.3.2 Create Backup PRC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 202.3.3 Modify Logical Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 212.3.4 Start Traffic on Extended Cell . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
2.3.5 Call Tests . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 282.3.6 Create Adjacencies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 292.3.7 Final Checks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
2.4 Reverse Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 302.4.1 Lock Cells . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 302.4.2 Restore Logical Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 302.4.3 Unlock Cells . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 312.4.4 Call Tests . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 312.4.5 Final Checks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
3BK 17430 0845 RJZZA Ed.05 3 / 32
8/4/2019 Create Extended Cell
4/32
Contents
4 / 32 3BK 17430 0845 RJZZA Ed.05
8/4/2019 Create Extended Cell
5/32
Preface
Preface
Purpose This document describes how to create extended cells on an 9100 BTS.
This method applies to BSS and OMC-R at technical release B10.
Whats New In Edition 05
Improve Presentation (Section 1.1) due to 3 extended cells allowance onBTS and Multiple CCCH support.
In Edition 04
Update with the new equipment naming.
In Edition 03
Restriction 3BKA20FBR230654 added in Create Adjacencies (Section 2.3.6).
In Edition 02
Delivered in release.
Update in Applicable Documents (Section 1.5.3)
First official release of the document for B10 MR2.
In Edition 01
Overall document quality was improved following an editorial review.The following sections were updated:
Create Extended Inner (Section 2.3.3.2)
Create Extended Outer (Section 2.3.3.3).
Start Traffic on Extended Cell (Section 2.3.4)
First official release of the document for B10.
Audience This document is intended for:
Field service technicians
Specialists
3BK 17430 0845 RJZZA Ed.05 5 / 32
8/4/2019 Create Extended Cell
6/32
Preface
Project managers
Foremen.
6 / 32 3BK 17430 0845 RJZZA Ed.05
8/4/2019 Create Extended Cell
7/32
Preface
Assumed Knowledge You must have a basic understanding of the following:
Planning:
Network architecture and reshuffling principles
Scheduling.
Implementation:
Alcatel-Lucent operations and maintenance concepts for the BSS
9153 OMC-R operation
Equipment (BSC, BTS, MFS) hardware configurations
Windows environment.
3BK 17430 0845 RJZZA Ed.05 7 / 32
8/4/2019 Create Extended Cell
8/32
Preface
8 / 32 3BK 17430 0845 RJZZA Ed.05
8/4/2019 Create Extended Cell
9/32
1 Overview
1 Overview
This Overview gives information needed by project managers and foremen, forpresentation to the customer and for site planning.
3BK 17430 0845 RJZZA Ed.05 9 / 32
8/4/2019 Create Extended Cell
10/32
1 Overview
1.1 Presentation
This scenario describes how to create and configure extended cells.
The maximum range defined in GSM for the access to a cell is 35 km. Thegoal of an extended cell is to increase the maximum distance between the
BTS and the MS, without changing the Air interface, to 70 km. Two differentcells are combined in order to create the extended cell. One cell (ExtendedInner) covers the range from 0 to 35 km and another cell (Extended Outer)covers the range from 35 to 70 km.
According to the engineering rules:
For 9100 BTS, the extended cell allows for several non -hopping TRXs
Extended cells are supported only on 9100 BTS with SUMA
LCS is supported on extended cells
GPRS is supported on extended cells
Both GSM and DCS frequency bands are allowed for extended cells
3 extended cells per BTS are allowed: 3 times (inner + outer)
Multiple CCCH is not supported in Extended Cell.
1.1.1 Cases
The following cases apply:
C1: Create Extended Cell
C1.1: Create Extended Inner Cell
C1.2: Create Extended Outer Cell.
C2: Modify Single Cell to Extended Cell
C2.1: Modify Single Cell to Extended Inner Cell
C2.2: Modify Single Cell to Extended Outer Cell.
Note: You can combine different cases to create the required configuration:
To create an complete Extended Cell, use a combination of C1.1and C1.2
If one cell is already created, use a combination of C1.1 and C2.2 or C1.2
and C2.1
If both cells must be modified, use a combination of C2.1 andC2.2.
1.1.2 Options
O1: GPRS on extended cell can apply.
1.1.3 Restrictions
None.
10 / 32 3BK 17430 0845 RJZZA Ed.05
8/4/2019 Create Extended Cell
11/32
1 Overview
1.1.4 Grouped Task Sequence
The following figure shows the grouped task sequence for this scenario.
MSC OMCR
Initial Checks
BTS
Create Backup PRC
Create Extended Inner Cell
Create Working PRC
Call Tests
Create Extended Outer Cell
Check Working PRC
Start Trafiic on Extended Cell
Final Checks
Create Adjancencies
3BK 17430 0845 RJZZA Ed.05 11 / 32
8/4/2019 Create Extended Cell
12/32
1 Overview
1.2 Preparation
1.2.1 Prerequisites
The following prerequisites apply:
9100 is installed and qualified
Two sectors are needed: one for Extended Outer and one for Extended
Inner cell
Extended Outer Cell and Extended Inner Cell must have the same
Frequency Range
Enough resources (in terms of Abis timeslots and TCU)
The antenna(e) are verified and functional.
1.2.2 Site Specific InformationAt the OMC-R, a workstation must be available.
1.2.3 External Tasks
None.
12 / 32 3BK 17430 0845 RJZZA Ed.05
8/4/2019 Create Extended Cell
13/32
1 Overview
1.3 Scheduling
Note: Time based on technical constraints
In the following table, the number of resources shown does not take intoaccount individual customer or safety requirements.
Grouped Task OMC-R Time/Task
Initial Checks 1 ope.
15 min.
15 min.
Create Backup PRC 1 ope.
6 min.
6 min.
1 ope.
3 min.
3 min.Create Working PRC
C2: + 11 min./ cell C2: + 11 min./cell
1 ope.
C1.1 13.5 min.
C1.1 13.5 min.Create Extended Inner
C2.1 1 min.
C2.2 1 min.
C2.1 +1 min.
C2.2 1 min.
Create Extended Outer 1 ope.
C1.2 11.5 min.
C1.2 11.5 min.
Check working PRC 1 ope.
1 min.
1 min.
1 ope.
3 min. + 5 min./ cell
31 min. + 5 min./ cellStart Traffic
C2: +4 min./ cell C2: +4 min./ cell
Call Tests 1 ope.
10min./ cell
10 min./ cell
Create Adjacencies 1 ope.
9min./ cell
9 min./ cell
3BK 17430 0845 RJZZA Ed.05 13 / 32
8/4/2019 Create Extended Cell
14/32
1 Overview
Grouped Task OMC-R Time/Task
Final Checks 1 ope.
15 min.
15 min.
Total time: 43 min. + 24 min./ cell
C1.1 +13.5 min.
C1.2 +11.5 min.
C2 +1 min. + 15 min./ cell
ope. : OMC-R Operator
14 / 32 3BK 17430 0845 RJZZA Ed.05
8/4/2019 Create Extended Cell
15/32
1 Overview
1.4 Telecom/Supervision Outage and Operating Impact
The following table describes the traffic outage and loss of supervision causedby each grouped task.
Out.Ref.
GroupedTask Tel. Out GPRS Out Tel. Red Sup.Out
Oper.Impact Impacts...
- InitialChecks.
- - - - - -
- CreateBackupPRC
- - - - - -
- CreateworkingPRC.
- - - - - -
- CreateBackupPRC.
- - - - - -
- CreateExtendedInner
- - - - - -
- CreateExtendedOuter.
- - - - - -
- CheckWorkingPRC
- - - - - -
1 StartTraffic onExtendedCell
C2: 3 min.+ 9 min./ cell
- - 1 min. 30sec.
- -
- Call Tests. - - - - - -
- Create
Adjacencies
- - - - - -
- FinalChecks.
- - - - - -
- TOTAL C2: 3 min. +9 min./ /cell
- - 1 min. 30sec.
- -
3BK 17430 0845 RJZZA Ed.05 15 / 32
8/4/2019 Create Extended Cell
16/32
1 Overview
1.5 Resources
1.5.1 Tools
The following tables describe the necessary hardware tools, software tools,
and forms.
1.5.1.1 Hardware Tools
Item Part Number Use at ...
Installation tools - BTS
Mobile phone (bi-band, if possible) for call tests. - BTS
1.5.1.2 Software Tools
Item Part Number Use at ...
Customer Documentation CD with the versionassociated with the current document edition.Remember that the document you are readingcannot be used as a paper version. It is onlinedocumentation using hypertext links which takeyou to other parts of a document on the sameCD-ROM. All words in italics are hypertext links.
- BTS, OMC-R
1.5.1.3 FormsNone.
1.5.2 Supplies
None.
1.5.3 Applicable Documents
You must have the following documents or have electronic access to thefollowing documents:
B10 BSS Methods Handbook
BSS Configuration Handbook
BSS Surveillance Handbook
Network Reconfiguration Recommendations
BTS NEM User Guide.
16 / 32 3BK 17430 0845 RJZZA Ed.05
8/4/2019 Create Extended Cell
17/32
2 Scenario
2 Scenario
This Scenario presents all checks needed before beginning the scenario, andall detailed tasks to be performed on each site.
3BK 17430 0845 RJZZA Ed.05 17 / 32
8/4/2019 Create Extended Cell
18/32
2 Scenario
2.1 Before Going Onsite
Before going onsite, you must check that the following information and suppliesare available:
All Prerequisites (Section 1.2.1) are met
The customer has been informed of the:
Date and time
Site name and address
Purpose of operation.
Personnel are available (refer to Scheduling (Section 1.3))
Site Specific Information (Section 1.2.2) is available
Tools (Section 1.5.1) are available and ready for operation
Supplies (Section 1.5.2) are available and ready for operationApplicable Documents (Section 1.5.3) are available.
Ensure that the technical release level of the delivered board is in accordancewith the BSS hardware technical release document.
Ensure that the method used at the BSS site is at the same level as at theOMC-R.
18 / 32 3BK 17430 0845 RJZZA Ed.05
8/4/2019 Create Extended Cell
19/32
2 Scenario
2.2 Before You Start
2.2.1 Checks
Perform the following operations:
Check that all Prerequisites (Section 1.2.1) are met
Check the availability of all necessary Tools (Section 1.5.1) and Supplies
(Section 1.5.2)
Inform the operator.
Among the cases described in Cases (Section 1.1.1) and the options describedin Options (Section 1.1.2), identify which cases and options apply to you.
2.2.2 Required KnowledgeYou must be familiar with the following:
Safety Rules and Precautions
Telecom/Supervision Outage and Operating Impact (Section 1.4)
The Reverse Procedure
Grouped Task Sequence (Section 1.1.4)
Operating Hints
How to document Faults and Anomalies.
3BK 17430 0845 RJZZA Ed.05 19 / 32
8/4/2019 Create Extended Cell
20/32
2 Scenario
2.3 Scenario Description
This section describes how to create or configure an external cell.
Note: Case-specific tasks are marked with C1, C2 in the Note column. Detailed tasksthat do not have C1, C2 in the Note column are common to all cases and
must always be performed.
2.3.1 Initial Checks
Note Task Description Site To Do Outage
- Perform an Audit Alarm State on the BSS. OMC-R 10 min. None.
- View Status of Managed Objects and Alarms on allthe impacted TSUs (BTSs and Abis, if necessary).
Print the reports and close the windows.
OMC-R 5 min. None.
2.3.2 Create Backup PRC
Note Task Description Site To do Outage
OMC-R 1 min. None.- Create PRC(Backup PRC), in restricted mode.
The PRC opens automatically.This task creates a backup PRC for theReverse Procedure (Section 2.4).
- Copy BTS to PRC. OMC-R 2 min. None.
OMC-R 1 min. None.- Copy OMC Cells to PRC, if any.
Copy impacted cell(s) to Backup PRC;the cells belonging to the impacted BTS.
- Check PRC (check all, without forcing the CellAdministrative State).
If the check produces error messages, correct theconfiguration as required and re-attempt the check.Continue corrections and checks until no error
messages appear.
OMC-R 1 min. None.
- Close PRC (Backup PRC). OMC-R 1 min. None.
20 / 32 3BK 17430 0845 RJZZA Ed.05
8/4/2019 Create Extended Cell
21/32
2 Scenario
2.3.3 Modify Logical Parameters
2.3.3.1 Create Working PRC
Note Task Description Site To do Outage
C2 Lock GPRS on Cell for the cell which will becomeExtended Inner or Extended Outer, if the cell isconfigured with GPRS.
OMC-R 4 min. / cell
None.
- Create PRC (Working PRC). The PRC opensautomatically.
OMC-R 1 min. None.
- Copy BTS to PRC OMC-R 2 min. None.
OMC-R 2 min./cell None.C2 Copy OMC Cells to PRC.
Note:Copy all the cells of the BTS,
including the ones which will becomeExtended Inner or Extended Outer, intothe PRC.
OMC-R 1 min./cell None.C2 If the Hopping Type on the cell which will becomeExtended Inner or Extended Outer is different thanNH, use Configure Logical Channels. Note:The TRX channel hopping law
will be removed.
OMC-R 1 min./cell NoneC2 Delete Frequency Hopping System.
Note:In the "Frequencies View"window, put NH for the Hopping Type
and Altern. Hop. Type fields.
C2 Change Cell Type to Extended Inner for the cellwhich will become Extended Inner, or to ExtendedOuter for the cell which will become ExtendedOuter.
OMC-R 1 min./cell None
OMC-R 2 min./ cell None.C2
O1
If the Extended Inner or Outer Cell has GPRS, useSet Cell Telecom Parameters to check and modify(if necessary) the GPRS parameters as follows:
MAX_PDCH, MAX_PDCH_HIGH_LOAD and
MIN_PDCH must have even valuesNB_TS_MPDCH must be set to 0 when the cell
type is Extended Inner / Outer
MAX_EGPRS_MCS is MCS4 for Extended
Outer and MCS9 is for Extended Inner
EN_NACC, EN_PSI_STATUS and
EN_STREAMING are disabled.
Note:If LCS was activated on thecell, and the operator wants to keep itactivated, do not set MAX_PDCH=0 on
these cells.
3BK 17430 0845 RJZZA Ed.05 21 / 32
8/4/2019 Create Extended Cell
22/32
2 Scenario
2.3.3.2 Create Extended Inner
Note Task Description Site To do Outage
C1.1 Create Provisioning Cell.
The cell is created in Working PRC and is in alocked state.
OMC-R 2 min. None.
OMC-R 2 min. None.C1.1 Use Set Cell Telecom Parameters.
Note:
Set EN_PBGT_FILTERING to
Disabled
To have LCS on the cell, set
MAX_PDCH>0
If the Extended Inner / Outercells are PS capable, they must
have the same value for the
ACCESS_BURST_TYPE parameter.
22 / 32 3BK 17430 0845 RJZZA Ed.05
8/4/2019 Create Extended Cell
23/32
2 Scenario
Note Task Description Site To do Outage
OMC-R 2 min. None.C1.1
O1
To configure GPRS on a cell:
Set the Routing Area Code
Set the Routing Area Color
MAX_PDCH, MAX_PDCH_HIGH_LOAD and
MIN_PDCH must have even values
NB_TS_MPDCH must be set to 0 when the cell
type is Extended Inner / Outer
MAX_EGPRS_MCS is MCS9
EN_NACC, EN_PSI_STATUS and
EN_STREAMING are disabled
When GPRS is created on the cell, you can alsomodify the following parameters:
Min_PDCH
NB_TS_MPDCH
Max_Pdch_High_Load
En_fast_initial_GPRS_access
Ps_Pref_Bcch_Trx
max_GPRS_Cs
max _EGPRS_Mcs
En_EGPRS
If LCS with AGPS is activated, you can also modifythe EN_CONV_GPS, EN_MS_Assisted_AGPSand EN_MS_BASED_AGPS parameters.
To have EGPRS on the extended cell:
Both inner and outer cells must have EGPRS
declared (the EN-EGPRS parameter is set to
Enable)
All TRXs from inner and outer cells mustsupport EDGE (all TRXs are TRAs).
Note:
To have GPRS on the cell,
Trx_Pref_Mark must be 0 for at least
one TRX.To modify it for a block of TRX,use the Java Script Set/UpdateCircuit/Packet Mark ConfigurationUsing Script.
To modify only one cell, use the
edit cell command (see Set Cell
Telecom Parameters)
If En_fast_initial_GPRS_access isset to Enable, respect the following
rule:Min_PDCH >=En_fast_initial_GPRS_access +NB_TS_MPDCH.
OMC-R 0.5 min. None.C1.1 Create Radio Frequency.
Note:Use only Non Hopping for theHopping Type.
C1.1 Create TRX. OMC-R 0.5min./TRX
None.
C1.1 Configure Logical Channels. OMC-R 1 min. None.
3BK 17430 0845 RJZZA Ed.05 23 / 32
8/4/2019 Create Extended Cell
24/32
2 Scenario
Note Task Description Site To do Outage
C1.1 Configure TRX. OMC-R 0.5min./TRX
None.
OMC-R 0.5 min./ TRX None.C1.1 Specify TRX Preference.
Note:Select a non-null value.
C1.1 Click on [ Apply and check ] in the "Edit Cell"window to save cell modifications in the WorkingPRC.
Wait for the No error or warning message andclick on [ Ok ].
If the check produces error messages, correctthe configuration as required and re-attempt the
check. Continue corrections and checks until noerror messages occur.
OMC-R 0.5 min. None.
C1.1 Change Cell Type of the single cell to ExtendedInner.
OMC-R 1 min. None
OMC-R 1 min. NoneC2.2 Use Change Mate Cellto set Mate Cell parametersfor the Extended Inner Cell.
Note:Set the Mate Cell parameter toPresent
Mate cells must have the same LACand the same BSIC.
OMC-R 1 min. None.C1.1 Map Cell to a BTS Sector.
Note:Map the Extended Inner Cell.
24 / 32 3BK 17430 0845 RJZZA Ed.05
8/4/2019 Create Extended Cell
25/32
2 Scenario
2.3.3.3 Create Extended Outer
Note Task Description Site To do Outage
OMC-R 2 min. None.C1.2 Use Create Mate Cell to create anExtended Outer Cell.
Note:Extended Inner and Extended Outer mate cellsmust have the same LAC and the same BSIC
Select ExtendedOuter for the Cell Type parameter.
OMC-R 2 min. None.C1.2 Use Set Cell Telecom Parameters.
Note:Set EN_PBGT_FILTERING to Disabled
To have LCS on the cell, set MAX_PDCH>0
If the Extended Inner / Outer cells are PScapable, they must have the same value for theACCESS_BURST_TYPE parameter.
3BK 17430 0845 RJZZA Ed.05 25 / 32
8/4/2019 Create Extended Cell
26/32
2 Scenario
Note Task Description Site To do Outage
OMC-R 2 min. NoneC1.2
O1
To configure GPRS on a cell:
Set the Routing Area Code
Set the Routing Area Color
MAX_PDCH,
MAX_PDCH_HIGH_LOAD
and MIN_PDCH must have even
values
NB_TS_MPDCH must be set to
0 when the cell type is Extended
Inner / Outer
MAX_EGPRS_MCS is MCS4 for
Extended Outer
EN_NACC, EN_PSI_STATUS
and EN_STREAMING are
disabled.
When GPRS is created on the cell,you can also modify the followingparameters:
Min_PDCH
NB_TS_MPDCH
Max_Pdch_High_Load
En_fast_initial_GPRS_access
Ps_Pref_Bcch_Trx
max_GPRS_Cs
max _EGPRS_Mcs
En_EGPRS
If LCS with AGPS isactivated, you can alsomodify the EN_CONV_GPS,EN_MS_Assisted_AGPS andEN_MS_BASED_AGPS parameters.
To have EGPRS on the extendedcell:
Both inner and outer cells must
have EGPRS declared (the
EN-EGPRS parameter is set to
Enable)
All TRXs from inner and outer
cells must support EDGE (allTRXs are TRAs).
Note:
To have GPRS on the cell, Trx_Pref_Mark must be 0
for at least one TRX.To modify it for a block of TRX, use the Java Script Set
/ Update Circuit / Packet Mark Configuration UsingScript.
To modify only one cell, use the edit cell command
(see Set Cell Telecom Parameters)
If En_fast_initial_GPRS_access is set to Enable,
respect the following rule:Min_PDCH >= En_fast_initial_GPRS_access +
NB_TS_MPDCH.
26 / 32 3BK 17430 0845 RJZZA Ed.05
8/4/2019 Create Extended Cell
27/32
2 Scenario
Note Task Description Site To do Outage
OMC-R 0.5 min. None.C1.2 Create Radio Frequency.
Note:Use only Non Hopping for the Hopping Type.
C1.2 Create TRX. OMC-R 0.5 min./ TRX None.
C1.2 Configure Logical Channels. OMC-R 1 min. None.
C1.2 Configure TRX. OMC-R 0.5 min./TRX None.
C1.2 Specify TRX Preference. OMC-R 0.5 min./ TRX None.
C1.2 Click on [ Apply and check ] inthe "Edit Cell" window to save cellmodifications in the Working PRC.
Wait for the No error or warningmessage and click on [ Ok ].
If the check produces errormessages, correct the configurationas required and re-attempt thecheck. Continue corrections andchecks until no error messagesoccur.
OMC-R 0.5 min. None.
OMC-R 1 min. None.C1.2 Map Cell to a BTS Sector.
Note:Map the Extended Outer cell.
2.3.3.4 Check Working PRC
Note Task Description Site To do Outage
OMC-R 1 min. None.Use the Check All option in Check PRC(WorkingPRC) (without forcing the Cell Administrative State)to check the parameters, hardware, and telecomimpact of your PRC.
If the check produces error messages, correct theconfiguration as required and re-attempt the check.
Continue corrections and checks until no errormessages appear.
Note:For C2: For the cell which wasmodified from single to Extended Inneror Outer, ignore the following errormessage:
Cell should be locked.
3BK 17430 0845 RJZZA Ed.05 27 / 32
8/4/2019 Create Extended Cell
28/32
2 Scenario
2.3.4 Start Traffic on Extended Cell
Note Task Description Site To Do Outage
OMC-R 4 min./ Cell START1C2 Shutdown Cell (WTC = 3 min.)
Note:Shut down the cell which wasmodified from single to Extended Inner orOuter.
OMC-R 5 min./ cell Outage 1- Activate PRC(Working PRC) in queued mode,with cell clean-up, without forcing the CellAdministrative State.
Display Pending Activations List to see whenthe activation is finished.
The activation time depends on the numberof cells activated.
During the activation, supervision outage: 1min. 30 sec.
- Close PRC (Working PRC). OMC-R 1 min. Outage 1
- Perform Bar Cell for all extended inner cells. OMC-R 1 min. Outage 1
- Use Unlock Cell for all the cells that were shutdown and for the new cells.
OMC-R 2 min. Outage 1
O1 If GPRS is locked Unlock GPRS Traffic on Cellfor the extended cell.
OMC-R 2 min. END1
2.3.5 Call Tests
Note Task Description Site To Do Outage
BTS 5 min./ cell None.- Perform Call Test for the Extended Inner andOuter cell.
This task must be done in parallel with thenext task.
Unlock Cell from Call Test is not necessaryhere.
CHECK Display USD Detailed Cell Information.
Check that calls are performed on the newcells. If calls fail, go to the Reverse Procedure(Section 2.4).
OMC-R 5 min./ cell None.
O1 Perform GPRS calls on the extended cell(Inner / Outer).
Check in the DTC report that each GPRS callis successful and print the DTC-report.
OMC-R 15 min. None.
28 / 32 3BK 17430 0845 RJZZA Ed.05
8/4/2019 Create Extended Cell
29/32
2 Scenario
2.3.6 Create Adjacencies
RESTRICTION3BKA20FBR230654
When creating adjacencies, make sure to take into account that for one BSConly a maximum of 64 HOs are allowed.
Note Task Description Site To Do Outage
OMC-R 5 min./ newcell(s)
None.- Create Adjacency for the new cells.
Note:Create adjacencies between the ExtendedInner and Extended Outer Cell.
- For each cell on the same OMC-R thatmust be adjacent to the new cells, ModifyAdjacencyto include the new cells.
OMC-R 2 min./ cell None.
- For each cell on the neighboring OMC-Rsthat must be adjacent to the new cells,Modify Adjacency on neighboringOMC-Rs to include the new cells.
neighborOMC-R
2 min./ cell None.
2.3.7 Final Checks
Note Task Description Site To Do Outage
- Perform an Audit Alarm State on the BSS. OMC-R 10 min. None.
CHECK View Status of Managed Objects and Alarmson all the impacted TSUs (Abis and BTSs).
Compare with reports from Initial Checks(Section 2.3.1).
OMC-R 5 min. None.
3BK 17430 0845 RJZZA Ed.05 29 / 32
8/4/2019 Create Extended Cell
30/32
2 Scenario
2.4 Reverse Procedure
This section describes how to reverse the Create Extended Cell.
2.4.1 Lock Cells
Note Task Description Site To Do Outage
- In the SC, use Shut Down Cell Traffic to shutdown all cells of the downstream BTSs (WTC = 3min.). The GSM and GPRS traffic stops.
OMC-R 4 min./ cell -
2.4.2 Restore Logical Configuration
Note Task Description Site To do Outage
C1 Create PRC (Delete_cell PRC).
The PRC opens automatically.
OMC-R 1 min. -
C1 Copy BTS to PRC OMC-R 2 min. -
OMC-R 2 min. -C1 Copy OMC Cells to PRC
Note:Copy Extended Inner and ExtendedOuter cells.
C1 Use Delete OMC Cell from PRC to delete
Extended Outer and Extended Inner cells.
OMC-R 1 min. -
C1 Use the Check All option in Check PRC(Delete_cell PRC) (without forcing the CellAdministrative State) to check the parameters,hardware, and telecom impact of your PRC.
OMC-R 1 min. -
OMC-R 5 min./ cell -C1 Activate PRC(Working PRC) in queued mode,with cell clean-up, without forcing the CellAdministrative State.
Display Pending Activations List to see whenthe activation is finished.
The activation time depends on the numberof cells activated.
During the activation, supervision outage: 1
min. 30 sec.
C1 Close PRC (Delete_cell PRC). OMC-R 1 min. -
- Open PRC (Backup PRC). OMC-R 1 min. -
OMC-R 5 min./ cell -- Activate PRC (Backup PRC) in queued mode,without cell clean-up, without forcing the CellAdministrative State.
Display Pending Activations List to see whenthe activation is finished.
The activation time depends on the numberof cells activated.
30 / 32 3BK 17430 0845 RJZZA Ed.05
8/4/2019 Create Extended Cell
31/32
2 Scenario
Note Task Description Site To do Outage
- Close PRC (Backup PRC). OMC-R 1 min. -
- Delete PRC.
(Delete both the Backup PRC and WorkingPRC).
OMC-R 2 min./ PRC -
2.4.3 Unlock Cells
Note Task Description Site To Do Outage
- In the SC, use Unlock Cellto unlock all cells. Trafficis restarted on the cells.
OMC-R 1 min. -
O1 If GPRS is locked Unlock GPRS Traffic on Cell forthe extended cell.
OMC-R 2 min. -
2.4.4 Call Tests
Note Task Description Site To Do Outage
BTS 5 min./ cell -- Perform Call Tests.
Perform call tests for all impacted cells.
CHECK Display USD Detailed Cell Information. OMC-R 5 min./ cell -
O1 Perform GPRS calls on the extended cell (Inner/ Outer).
Check in the DTC report that each GPRS call issuccessful and print the DTC report.
OMC-R 15 min. None.
2.4.5 Final Checks
Note Task Description Site To Do Outage
- Perform an Audit Alarm State on the BSS. OMC-R 10 min. -
CHECK View Status of Managed Objects and Alarms onall the impacted TSUs (Abis and BTSs).
Compare with reports from Initial Checks (Section2.3.1).
OMC-R 5 min. -
3BK 17430 0845 RJZZA Ed.05 31 / 32
8/4/2019 Create Extended Cell
32/32
2 Scenario
BLANK PAGE BREAK