Craniotomy ProductsC A T A L O G
482848.Q7:482848.Q7 6/4/08 7:37 AM Page 1a
CODMAN cornerstone
craniotomy products
offer the neurosurgical
community the most
comprehensive line of
products to fill their
needs while performing
craniotomies.
175724.Q7:175724.Q7 3/12/08 4:01 PM Page 1b
N E U R O D I S P O S A B L E S
A N E U R Y S M C L I P S Y S T E M
1
A I R D R I V E R S E T S
CO
NT
EN
TS
Page
Patties and Strips 2
Family of Perforators 3
Craniotomy Kits 3
BICOL 4
Cranioplastic 4
Aneuroplastic 4
Scalp Clips & Applier 5
Surgical Markers 6
Page
Unitized 9
Modular 9
Page
Aneurysm Clips 10-15
AVM Micro Clips 16
Mini Clip System 18
Temporary Clips 19
Graft Clips 19-20
Clip Microcare Tray System 21
175724.Q7:175724.Q7 3/10/08 12:31 PM Page 1
N E U R O D I S P O S A B L E S
For more information, contact your CODMAN Sales Representative • For product information, call (800) 225-0460 • www.codman.com2
CODMAN SURGICAL PATTIES & STRIPS
CODMAN Surgical Patties & Strips provide the neurosurgeon with softness, gentleness, protection and absorbency to meetthe demands of delicate intracranial and spinal surgery.
• Absorbency - CODMAN Patties & Strips absorb more than 5 times their weight in less than a second.
• Precision Cut - CODMAN patties and strips precision cut provides smooth edges and helps prevent linting.
• Cottonoid® Material - Cottonoid compressed rayon provides the natural softness, absorbency and pliability of cotton.A special process interweaves individual rayon fibers to resist shedding, stretching or linting – whether wet or dry.
• Soft and Gentle - SutureWeld®’s Strong bond holds the indicator string to the pattie so the surface which lies next totissue is completely smooth and free of stitches.
• Pliable and Porous - Cottonoid material offers the advantage of being porous so CODMAN Patties & Strips easilyconform to the intricate contours of delicate tissue. Yet, you can safely suction through them without aspirating the tissue orthe pattie or strip.
• X-Ray Detectable - Marking is where it should be – on the pattie or strip.
• Unique Packaging - A transparent, sterile envelope shows the size and shape of patties and strips, and the CountVerification Card instantly shows how many patties you started with and how many were used.
CODMAN SURGICAL PATTIESSterile, x-ray detectable, 10 patties per package, 20 packages per dispenser box
Product Code Length /Description
80-1396 5/16” Round (.79cm)80-1397 1/4” x 1-1/2” (64cm x 3.81cm)80-1398 1/4” x 3” (64cm x 7.62cm)80-1399 1/4”x 1/4” (64cm x 64cm)80-1400 1/2” x 1/2” (1.27cm x 1.27cm)80-1401 3/4” x 3/4” (1.91cm x 1.91cm)80-1402 1/2” x 1” (1.27cm x 2.54cm)80-1403 1” x 1” (2.54cm x 2.54cm)80-1404 1/2” x 1-1/2” (1.27cm x 3.81cm)80-1406 1/2” x 2” (1.27cm x 5.08cm)80-1407 1/2” x 3” (1.27cm x 7.62cm)80-1408 1” x 3” (2.54cm x 7.62cm)80-1409 3” x 3” (7.62cm x 7.62cm)
CODMAN SURGICAL STRIPSSterile, x-ray detectable, 10 patties per package, 20 packages per dispenser box
Product Code Length /Description
80-1449 1/8” x 6” (3mm x 152mm)80-1450 1/4” x 6” (6mm x 152mm)80-1451 1/2” x 6” (13mm x 152mm)80-1452 3/4”x 6” (19mm x 152mm)80-1453 1” x 6” (25mm x 152mm)80-1454 1-1/2” x 6” (38mm x 152mm)80-1455 2” x 6” (51mm x 152mm)80-1456 3” x 6” (76mm x 152mm)80-1457 3-1/2” x 6” (89mm x 152mm)
175724.Q7:175724.Q7 3/10/08 12:32 PM Page 2
N E U R O D I S P O S A B L E S C A T A L O GNEURODIS
POSABLES
For more information, contact your CODMAN Sales Representative • For product information, call (800) 225-0460 • www.codman.com 3
FAMILY OF PERFORATORS
CODMAN DISPOSABLE PERFORATOR FAMILYCODMAN Disposable Perforator with Hudson end. Individually sterilized, one per package. Sterile, sharp,disposable perforators. Designed for use in perforating the cranium. 100% Quality Testing: All units arepretested to meet specifications.
• Available in three convenient sizes; 9mm, 11mm, and 14mm
• Also available in Craniotomy Kits
• Perforators are color-coded for easy identification
Product Code Length /Description
26-1221 CODMAN Disposable Perforator,14mm
26-1222 CODMAN Disposable Perforator,11mm
26-1223 CODMAN Disposable Perforator,9mm
CODMAN CRANIOTOMY KIT - DISPOSABLECODMAN brings you a complete craniotomy system in a convenient three-piece kit. Included for each size are aCODMAN Disposable Perforator, CODMAN Cranio-blade and CODMANWire Pass Drill with the following features:
• CODMAN Disposable Perforators - Single use, sterile, Color-coded sizes, No maintenance required, Sharp
• CODMAN Cranio-blade - Four-fluted channel, Single use, Sterile
• CODMAN Wire Pass Drill - Single use, Sterile
Product Code Length /Description
26-1230 Craniotomy Kit, 14mm
26-1231 Craniotomy Kit, 11mm
26-1229 Craniotomy Kit, 9mm
26-1246 Cranio-blade Sterile, disposable,five per package
26-1247 Wire Pass Drill Sterile, disposable,five per package
26-122211mm/8mm
26-122114mm/11mm
26-12239mm/6mm
175724.Q7:175724.Q7 3/10/08 12:32 PM Page 3
N E U R O D I S P O S A B L E S
For more information, contact your CODMAN Sales Representative • For product information, call (800) 225-0460 • www.codman.com4
BICOL® COLLAGEN SPONGE – PROVEN QUALITY
BICOL Collagen sponge is a highly useful adjunct to neurosurgery as a moistening agent and as a protective device. The inherentcomposition of the material provides exceptional wet strength while maintaining its soft, pliable and resilient nature.
• MoisteningAs a moistening agent, the BICOL Collagen Sponge is highly efficient during prolonged periods of exposure. The material canrapidly absorb and maintain up to 60 times its weight in aqueous fluid, in comparison to the standard gelatin sponge, UPS,which absorbs about 30 times its weight. Additionally, its microfibrillar structure sustains its pliability and prevents moistenedmaterial from crumbling or breaking apart while handling.
• ProtectionAs a protective device the resilient nature of the moistened material effectively buffers the pressure of a retractor blade. After itsrapid initial wetting, there is little change in its overall volume and no change with the passage of time following application.
• ApplicationApplication and manipulation of the wetted material is facilitated by its surface textures. One surface is very smooth so thatonce moistened it slides over the brain and readily conforms to the area to be protected. The opposite surface has sufficientgrain to provide friction to a retractor blade for manipulation.
BICOL COLLAGEN SPONGEPackaged individually, sterile, ten packages per box
Product Code Length /Description
80-1460 3” (76mm) x 4” (102mm)
CRANIOPLASTIC KITCranioplastic is a resinous material for repairing cranial defects.
Product Code Length /Description
43-1050 Two complete sets consist of two bags sterilepowder (net weight 30 grams each), two vialssterile liquid (net contents 17 milliliters each),and two sterile matrix bags
ANEUROPLASTIC KITAneuroplastic is a fast-setting resinous material which is used to encapsulate cerebral aneurysms.
Product Code Length /Description
43-1060 Two complete sets consist of two bags sterilepowder (net weight 30 grams each), twoampules sterile liquid (net content 17 milliliterseach), and two sterile matrix bags
175724.Q7:175724.Q7 3/10/08 12:32 PM Page 4
N E U R O D I S P O S A B L E S C A T A L O GN
EURO
DIS
PO
SABLES
For more information, contact your CODMAN Sales Representative • For product information, call (800) 225-0460 • www.codman.com 5
CODMAN RANEY SCALP CLIPS & APPLIER
CODMAN DISPOSABLE SCALP CLIPSProvides for hemostasis of scalp flap edges
Product Code Length /Description
20-1025 RANEY Scalp Clips Stainless steel, twelve clips per package.Use with 20-5115 RANEY Scalp Clip Applying Forceps
20-1032 LEROY Scalp Clips Sterile, disposable, plastic.Ten clips per package, twenty packages per case.Use with 20-5117 LEROY Scalp Clip Applying Forceps
20-1034 LEROY-RANEY Scalp Clips Sterile, disposable, plasticTen clips per package, twenty packages per caseUse with 20-5117 LEROY Scalp Clip Applying Forceps
20-1035 Infant LEROY Scalp Clips Sterile, disposable, plasticTen clips per package, twenty packages per caseUse with 20-5120 Infant LEROY Scalp Clip Applying Forceps
20-1037 RANEY Scalp Clips Sterile, disposable, plasticTen clips per package, twenty packages per caseUse with 20-5115 RANEY Scalp Clip Applying Forceps
20-1039 CODMAN Scalp Clip Removable ForcepsUse with 20-1038 CODMAN Disposable Scalp Clip Applier
CODMAN SCALP CLIP FORCEPSSingle-use clips used with:
Product Code Length /Description
20-5115 Raney Scalp Clip Applying Forceps. Use with 20-1037 or 20-1025 Raney Scalp Clips. Length 6-1/4” (157mm)
20-5117 Leroy Scalp Clip Applying Forceps. Adult size for use with 20-1032 or 20-1034 Leroy Scalp Clips. Length 7-1/4” (184mm)
20-5120 Infant Leroy Scalp Clip Applying Forceps. For use with 20-1035 Infant LEROY Scalp Clips. Length 7-1/4” (184mm)
THE CODMAN SCALP CLIP APPLIERThe CODMAN Scalp Clip Applier is a sterile, single-use system designed to apply scalp clips to the scalp flap for hemostasis during acraniotomy procedure. Comes with pre-loaded scalp clips. Permits rapid application of scalp clips. Provides adequate hemostasis
Product Code Length /Description
20-1038 CODMAN Disposable Scalp Clip Applier Sterile, plasticTen packages per case
20-5115
20-5117
175724.Q7:175724.Q7 3/12/08 3:41 PM Page 5
N E U R O D I S P O S A B L E S
For more information, contact your CODMAN Sales Representative • For product information, call (800) 225-0460 • www.codman.com6
CODMAN SURGICAL MARKERS
CODMAN offers two surgical marking pens to meet the need for both a bold and fine line marker. The CODMAN SurgicalMarker delivers a traditional bold line while the CODMAN Microsurgical Marker offers a particularly fine line for plastic andother delicate procedures. The tip on the CODMAN Microsurgical Marker is slightly flexible.
Important Features
• Both pens are completely filled with pre-resistant gentian violet ink to reduce the chance that they will dry out in storage.
• Individually packaged, sterile, in see-through peel pouches.
• Dispenser boxes make storage convenient.
• Each pen is packaged with a 15cm/6” disposable ruler.
CODMAN SURGICAL MARKER
Product Code Length /Description
43-1030 36 per case
CODMAN MICROSURGICAL MARKER
Product Code Length /Description
43-1032 36 per case
175724.Q7:175724.Q7 3/10/08 12:33 PM Page 6
N E U R O D I S P O S A B L E S C A T A L O GN
EURO
DIS
PO
SABLES
For more information, contact your CODMAN Sales Representative • For product information, call (800) 225-0460 • www.codman.com 7
175724.Q7:175724.Q7 3/10/08 12:33 PM Page 7
C R A N I O T O M E A I R D R I V E R S E T S
For more information, contact your CODMAN Sales Representative • For product information, call (800) 225-0460 • www.codman.com8
CRANIOTOME AIR DRIVER SETS
175724.Q7:175724.Q7 3/10/08 12:33 PM Page 8
N E U R O D I S P O S A B L E S C A T A L O GAIR
DRIVER
SETS
For more information, contact your CODMAN Sales Representative • For product information, call (800) 225-0460 • www.codman.com 9
CPS UNITIZED AIR CRANIOTOME SET
Product Code Length /Description
26-5030 CPS Unitized Air Craniotome SetIncludes the following:
26-5000 Modular Air Driver, Complete26-5001 1,000 RPM Unitized, Air Driver, Complete26-5003 Swiveling Dura Guard26-5004 Wire Pass Drill Guard26-5008 Fixed Dura Guard26-5009 Skull Perforator Guard26-5012 Stabilizing Handle26-5007 Air Hose, 10’
CPS MODULAR AIR CRANIOTOME SET
Product Code Length /Description
26-5040 CPS Modular Air Craniotome SetIncludes the following:
26-5000 Modular Air Driver, Complete
26-5002 1,000 RPM Modular Attachment
26-5003 Swiveling Dura Guard
26-5004 Wire Pass Drill Guard
26-5008 Fixed Dura Guard
26-5009 Skull Perforator Guard
26-5012 Stabilizing Handle
26-5007 Air Hose, 10’
CODMAN POWER SYSTEMS STERILIZING CASE
Product Code Length /Description
26-5015 Stainless steel, holds either a Unitized orModular Air Craniotome SetLength: 17-1/2” (44cm)Width: 10” (25cm)Depth: 2-1/2” (6cm)
175724.Q7:175724.Q7 3/10/08 12:34 PM Page 9
C O D M A N A N E U R Y S M C L I P S Y S T E M
For more information, contact your CODMAN Sales Representative • For product information, call (800) 225-0460 • www.codman.com10
System includes fenestrated, bayonet, reinforcing, straight,
angled and curved clips. A total of 104 clips designed for
all saccular and globular aneurysms.
• Strong clip closing pressure (Range from 110 to 330 grams)• MRI compatible.• When tested with MRI magnets of up to 1.5 Tesla, clips produce an insignificant
amount of force and torque.• Slim-Line design permits optimal visualization.• All clips marked with individual identification serial number and product code for
easy I.D. and traceability.
CODMAN ANEURYSM CLIP SYSTEM
482848.Q7.qxd:482848.Q7 6/5/08 4:58 PM Page 10
ANEURYSM CLIPS - STRAIGHT
Product Code Blade Minimum Blade Tray NumberLength Opening At Tip
20-1600 5mm 5mm 120-1601 7mm 6mm 120-1602 9mm 7mm 120-1603 12mm 8mm 120-1604 15mm 9mm 120-1605 20mm 10mm 120-1606 25mm 11mm 1
ANEURYSM CLIPS - SLIGHTLY CURVED
Product Code Blade Minimum Blade Tray NumberLength Opening At Tip
20-1610 8mm 7mm 120-1611 10mm 7mm 120-1612 12mm 7mm 120-1613 14mm 7mm 120-1614 16mm 9mm 120-1615 20mm 10mm 1
ANEURYSM CLIPS - CURVED
Product Code Blade Minimum Blade Tray NumberLength Opening At Tip
20-1620 7.5mm 6mm 320-1621 9.5mm 6mm 320-1622 11.5mm 7mm 3
ANEURYSM CLIPS - RIGHT ANGLE
Product Code Blade Minimum Blade Tray NumberLength Opening At Tip
20-1626 5mm 6mm 220-1627 7.5mm 6mm 220-1628 10mm 6mm 220-1629 15mm 6mm 2
ANEURYSM CLIPS - 30O FORWARD CURVE
Product Code Blade Minimum Blade Tray NumberLength Opening At Tip
20-1635 8mm 5mm 220-1636 12mm 6mm 220-1637 16mm 9mm 2
N E U R O D I S P O S A B L E S C A T A L O GCLIP
SYSTEM
S
For more information, contact your CODMAN Sales Representative • For product information, call (800) 225-0460 • www.codman.com 11
175724.Q7:175724.Q7 3/10/08 12:34 PM Page 11
ANEURYSM CLIPS - SIDEWARD ANGLE
Product Code Blade Minimum Blade Tray NumberLength Opening At Tip
20-1641 7mm 6mm 120-1642 9mm 7mm 120-1643 12mm 7mm 120-1644 15mm 8mm 1
ANEURYSM CLIPS - 30O FORWARD ANGLE
Product Code Blade Minimum Blade Tray NumberLength Opening At Tip
20-1648 7mm 6mm 120-1649 9mm 7mm 120-1650 12mm 7mm 120-1651 15mm 8mm 1
ANEURYSM CLIPS - BAYONET STRAIGHT
Product Code Blade Minimum Blade Tray NumberLength Opening At Tip
20-1655 5mm 5mm 120-1656 7mm 6mm 120-1657 9mm 7mm 120-1658 12mm 8mm 120-1659 15mm 8mm 120-1660 20mm 9mm 120-1661 25mm 10mm 1
ANEURYSM CLIPS - BAYONET (30O FORWARD-RIGHT)
Product Code Blade Minimum Blade Tray NumberLength Opening At Tip
20-1665 7mm 5mm 320-1666 9mm 6mm 3
ANEURYSM CLIPS - BAYONET (30O FORWARD-LEFT)
Product Code Blade Minimum Blade Tray NumberLength Opening At Tip
20-1670 7mm 5mm 320-1671 9mm 6mm 3
C O D M A N A N E U R Y S M C L I P S Y S T E M
For more information, contact your CODMAN Sales Representative • For product information, call (800) 225-0460 • www.codman.com12
175724.Q7:175724.Q7 3/10/08 12:35 PM Page 12
ANEURYSM CLIPS - SUPER BAYONET
Product Code Blade Minimum Blade Tray NumberLength Opening At Tip
20-1675 5mm 7mm 120-1676 7mm 7mm 120-1677 9mm 7mm 120-1678 12mm 8mm 120-1679 15mm 9mm 120-1680 20mm 10mm 120-1681 25mm 11mm 1
ANEURYSM CLIPS - SHARP RIGHT ANGLE
Product Code Blade Minimum Blade Tray NumberLength Opening At Tip
20-1682 6mm 5mm 220-1683 9mm 5mm 220-1684 12mm 5mm 2
ANEURYSM CLIPS - FENESTRATED, STRAIGHT, 6mm OPENING
Product Code Blade Minimum Blade Tray NumberLength Opening At Tip
20-1685 6mm 7mm 220-1686 9mm 8mm 220-1687 12mm 9mm 220-1688 16mm 9mm 220-1689 20mm 10mm 220-1690 24mm 11mm 2
ANEURYSM CLIPS - FENESTRATED 45O ANGLE, 6mm OPENING
Product Code Blade Minimum Blade Tray NumberLength Opening At Tip
20-1691 6mm 6mm 220-1692 9mm 8mm 220-1693 12mm 9mm 220-1694 16mm 9mm 220-1695 20mm 10mm 220-1696 24mm 11mm 2
ANEURYSM CLIPS - FENESTRATED, 90O ANGLE, 6mm OPENING
Product Code Blade Minimum Blade Tray NumberLength Opening At Tip
20-1697 6mm 6mm 220-1698 9mm 6mm 220-1699 12mm 6mm 2
N E U R O D I S P O S A B L E S C A T A L O GCLIP
SYSTEM
S
For more information, contact your CODMAN Sales Representative • For product information, call (800) 225-0460 • www.codman.com 13
175724.Q7:175724.Q7 3/10/08 12:35 PM Page 13
ANEURYSM CLIPS - FENESTRATED STRAIGHT, 3mm EXTENDED TANDEM, 6mm OPENING
Product Code Blade Minimum Blade Tray NumberLength Opening At Tip
20-1700 6mm 7mm 320-1701 9mm 8mm 320-1702 12mm 9mm 3
ANEURYSM CLIPS - FENESTRATED BAYONET, 5mm EXTENDED TANDEM, 6mm OPENING
Product Code Blade Minimum Blade Tray NumberLength Opening At Tip
20-1703 6mm 8mm 320-1704 9mm 9mm 320-1705 12mm 10mm 3
ANEURYSM CLIPS - GRAFT, 4mm DIAMETER
Product Code Blade Minimum Blade Tray NumberLength Opening At Tip
20-1715 3mm Width 4mm Diameter 320-1716 5mm Width 4mm Diameter 320-1717 7mm Width 4mm Diameter 3
ANEURYSM CLIPS - FENESTRATED 90O ANGLE, 4MM OPENING
Product Code Blade Minimum Blade Tray NumberLength Opening At Tip
20-1718 6mm 5mm 220-1719 9mm 5mm 220-1720 12mm 5mm 2
ANEURYSM CLIPS - FENESTRATED STRAIGHT, 4mm OPENING
Product Code Blade Minimum Blade Tray NumberLength Opening At Tip
20-1721 6mm 7mm 220-1722 9mm 8mm 220-1723 12mm 9mm 220-1724 16mm 9mm 220-1725 20mm 10mm 220-1726 24mm 11mm 2
C O D M A N A N E U R Y S M C L I P S Y S T E M
For more information, contact your CODMAN Sales Representative • For product information, call (800) 225-0460 • www.codman.com14
175724.Q7:175724.Q7 3/10/08 12:35 PM Page 14
ANEURYSM CLIPS - FENESTRATED 30O ANGLE, 4mm OPENING
Product Code Blade Minimum Blade Tray NumberLength Opening At Tip
20-1727 6mm 6mm 220-1728 9mm 8mm 220-1729 12mm 9mm 220-1730 16mm 8mm 220-1731 20mm 9mm 220-1732 24mm 10mm 2
ANEURYSM CLIPS - FENESTRATED BAYONET, STRAIGHT, 6mm OPENING
Product Code Blade Minimum Blade Tray NumberLength Opening At Tip
20-1733 6mm 7mm 220-1734 9mm 8mm 220-1735 12mm 9mm 220-1736 15mm 10mm 2
ANEURYSM CLIPS - REINFORCING 0O ANGLE, 6mm WIDE
Product Code Blade Minimum Blade Tray NumberLength Opening At Tip
20-1740 6mm 5mm 320-1741 12mm 5mm 320-1742 18mm 5mm 3
ANEURYSM CLIPS - REINFORCING 45O ANGLE, 6mm WIDE
Product Code Blade Minimum Blade Tray NumberLength Opening At Tip
20-1745 6mm 5mm 320-1746 12mm 5mm 320-1747 18mm 5mm 3
ANEURYSM CLIPS - REINFORCING 60O ANGLE, 6mm WIDE
Product Code Blade Minimum Blade Tray NumberLength Opening At Tip
20-1750 6mm 5mm 320-1751 12mm 5mm 320-1752 18mm 5mm 3
N E U R O D I S P O S A B L E S C A T A L O GCLIP
SYSTEM
S
For more information, contact your CODMAN Sales Representative • For product information, call (800) 225-0460 • www.codman.com 15
175724.Q7:175724.Q7 3/10/08 12:35 PM Page 15
C O D M A N A N E U R Y S M C L I P S Y S T E M
For more information, contact your CODMAN Sales Representative • For product information, call (800) 225-0460 • www.codman.com16
AVM MICRO CLIP SYSTEM
AVM Micro Clips and Appliers are for permanent occlusion of vessels in treating arterial venousmalformations. The AVM Micro Clip System is used in conjunction with bipolar coagulation forhemostasis of small perforating vessels during the surgical excision of arterial venous malformations.
• Clips are MRI compatible.
• Closing pressures range from 10 to 50 grams minimum.
• Clip blade lengths range from 1.0mm to 4.0mm.
A corresponding AVM Micro Clip Applier is designed for use with each AVM Micro Clip.
AVM MICRO CLIPSUse AVM Micro Tray 80-1840
Product Code Length/Description MinimumGrams/Pressure
20-1801 1.0mm, AVM Micro Clip #1 10mm
20-1802 1.5mm, AVM Micro Clip #2 20mm
20-1803 2.0mm, AVM Micro Clip #31 30mm
20-1804 3.0mm, AVM Micro Clip #4 40mm
20-1805 4.0mm, AVM Micro Clip #5 50mm
175724.Q7:175724.Q7 3/10/08 12:36 PM Page 16
N E U R O D I S P O S A B L E S C A T A L O GC
LI
PS
YS
TE
MS
For more information, contact your CODMAN Sales Representative • For product information, call (800) 225-0460 • www.codman.com 17
AVM APPLIERSApplies the corresponding AVM Clips only
Product Code Description Blade Length
20-1850 Micro Clip #1 1.0mm
20-1851 Micro Clip #2 1.5mm
20-1852 Micro Clip #3 2.0mm
20-1853 Micro Clip #4 3.0mm
20-1854 Micro Clip #5 4.0mm
175724.Q7:175724.Q7 3/10/08 12:36 PM Page 17
C O D M A N A N E U R Y S M C L I P S Y S T E M
For more information, contact your CODMAN Sales Representative • For product information, call (800) 225-0460 • www.codman.com18
MINI CLIP SYSTEM
The Mini Aneurysm Clip System is specifically designed for surgical treatmentof small aneurysms. Two size variations, #6 and #7, clips are available witheighteen total clips within the system. Clip design permits optimalvisualization of the aneurysm and strong closing forces for secure aneurysmocclusion. Clips are MRI compatible. All clips are marked with individualidentification serial number and product code for easy I.D. and traceability.
MINI ANEURYSM CLIPS
Use Mini Clip Tray 80-1835
Product Code Description Blade Length
20-1821 Mini Aneurysm Clip #6, straight 7mm20-1822 Mini Aneurysm Clip #6, slight curve 7mm20-1823 Mini Aneurysm Clip #6, forward curve 6mm20-1824 Mini Aneurysm Clip #6, slight curve 6mm20-1825 Mini Aneurysm Clip #6, straight 6mm20-1826 Mini Aneurysm Clip #6, bayonet 4.5mm20-1827 Mini Aneurysm Clip #6, right angle 4.5mm20-1828 Mini Aneurysm Clip #6, forward angle 5mm20-1829 Mini Aneurysm Clip #6, side angle 5mm20-1831 Mini Aneurysm Clip #7, slight curve 9mm20-1832 Mini Aneurysm Clip #7, straight 10mm20-1833 Mini Aneurysm Clip #7, bayonet 6mm20-1834 Mini Aneurysm Clip #7, right angle 5.5mm20-1835 Mini Aneurysm Clip #7, forward angle 8.5mm20-1836 Mini Aneurysm Clip #7, side angle 10mm20-1837 Mini Aneurysm Clip #7, forward curve 9.5mm20-1838 Mini Aneurysm Clip #6, straight 4mm20-1839 Mini Aneurysm Clip #7, slight curve 9.5mm
MINI ANEURYSM CLIP APPLIERS
Applies the corresponding #6 or #7 mini aneurysm clips
Product Code Description
20-1855 Mini Aneurysm Clip Applier #6
20-1856 Mini Aneurysm Clip Applier #7
482848.Q7:482848.Q7 5/13/08 9:12 AM Page 18
CL
IP
SY
ST
EM
S
For more information, contact your CODMAN Sales Representative • For product information, call (800) 225-0460 • www.codman.com 19
TEMPORARY CLIPS
Temporary Clips are used for temporary vascular occlusion during intracranial surgical procedures.Temporary Clips are MP35N alloy MRI compatible, gold colored for easy identification. The Temporary ClipSystem includes fifteen styles based on the existing Mini Clip sizes.
• Clip closing pressure ranges from 50 to 90 grams.
Mini Clip Appliers #6 and #7 are used with the Temporary Clip System.Use Temporary Clip Tray 80-1845
Product Code Length/Description Grams/Pressure
20-1860 6mm, Temporary Clip #6, slight curve 50-8020-1861 6mm, Temporary Clip #6, straight 50-8020-1862 5mm, Temporary Clip #6, side angle 65-9520-1863 9mm, Temporary Clip #7, slight curve 50-8020-1864 10mm, Temporary Clip #7, straight 50-8020-1865 6mm, Temporary Clip #7, bayonet 50-8020-1866 5.5mm, Temporary Clip #7, right angle 60-9020-1867 10mm, Temporary Clip #7, side angle 50-8020-1868 15mm, Temporary Clip #7, straight 50-8020-1869 15mm, Temporary Clip #7, slight curve 50-8020-1870 7mm, Temporary Clip #6, straight 55-8520-1871 9.5mm, Temporary Clip #7, slight curve 50-8020-1872 6mm, Temporary Clip #6, forward curve 50-8020-1873 9.5mm, Temporary Clip #7, forward curve 50-8020-1874 7mm, Temporary Clip #6, slight curve 50-80
**Temporary Clips identified by gold color.
GRAFT CLIPS
Graft Clips are used to encircle an artery in which a hole had developed as a result of a traumatic injury tothe vessel or from an aneurysm tearing at its base. Clips are MRI compatible and include an implantablewoven fabric that seals off the aneurysm after clip placement. All clips marked with individual serial numberand product code for easy I.D. and traceability. Appliers are used to apply the Graft Clips. The Graft Clip lineincludes 17 sizes, with barrel diameter from 2mm to 5mm and blade length from 3mm to 7mm.
Use Graft Clip Tray 80-1844
Product Code Encircling Diameter Barrel Width
20-1760 2mm 3mm20-1761 2mm 5mm20-1762 2.5mm 3mm20-1763 2.5mm 5mm20-1764 2.5mm 7mm20-1765 3mm 3mm20-1766 3mm 5mm20-1767 3mm 7mm20-1768 3.5mm 3mm20-1769 3.5mm 5mm
N E U R O D I S P O S A B L E S C A T A L O G
175724.Q7:175724.Q7 3/10/08 12:37 PM Page 19
C O D M A N A N E U R Y S M C L I P S Y S T E M
For more information, contact your CODMAN Sales Representative • For product information, call (800) 225-0460 • www.codman.com20
GRAFT CLIPS (CONTINUED)
Product Code Encircling Diameter Barrel Width
20-1770 3.5mm 7mm20-1715 4mm 3mm20-1716 4mm 5mm20-1717 4mm 7mm20-1771 5mm 3mm20-1772 5mm 5mm20-1773 5mm 7mm
ANEURYSM CLIP APPLIERS
Bayonet, stainless steel. Applies Graft Clips.
Product Code Tip/Length Working Distance
20-5205 Fixed Head, 8" (21cm) 3 3⁄4" (9.5cm)
20-5206 Hinged Head, 8" (21cm) 3 3⁄4" (9.5cm)
20-5203 Single hinge, 8" (21cm) 3 3⁄4"( 9.5cm)
175724.Q7:175724.Q7 3/10/08 12:37 PM Page 20
N E U R O D I S P O S A B L E S C A T A L O GC
LIP
SY
ST
EM
S
21
Fenestrated Straight,4mm diam.20-1721 6mm20-1722 9mm20-1723 12mm20-1724 16mm20-1725 20mm20-1726 24mm
Fenestrated 45˚, 4mm diam.20-1727 6mm20-1728 9mm20-1729 12mm20-1730 16mm20-1731 20mm20-1732 24mm
Fenestrated 90˚,4mm diam.20-1718 6mm20-1719 9mm20-1720 12mm
30o Forward Curve20-1635 8mm20-1636 12mm20-1637 16mm
Fenestrated Bayonet, 6mm20-1733 6mm20-1734 9mm20-1735 12mm20-1736 15mm
Fenestrated Straight,6mm diam.20-1685 6mm20-1686 9mm20-1687 12mm20-1688 16mm20-1689 20mm20-1690 24mm
Fenestrated 45˚, 6mm diam.20-1691 6mm20-1692 9mm20-1693 12mm20-1694 16mm20-1695 20mm20-1696 24mm
Fenestrated, 90˚,6mm diam.20-1697 6mm20-1698 9mm20-1699 12mm
Right Angle20-1626 5mm20-1627 7.5mm20-1628 10mm20-1629 15mm
Sharp Right Angle20-1682 6mm20-1683 9mm20-1684 12mm
Reinforcing Clips20-1740 6mm, 0˚20-1741 12mm, 0˚20-1742 18mm, 0˚20-1745 6mm, 30˚20-1746 12mm, 30˚20-1747 18mm, 30˚20-1750 6mm, 90˚20-1751 12mm, 90˚20-1752 18mm, 90˚
Fenestrated Tandem(6mm) diam.20-1700 6mm, 3mm extended20-1701 9mm, 3mm extended20-1702 12mm, 3mm extended20-1703 6mm, 5mm extended20-1704 9mm, 5mm extended20-1705 12mm, 5mm extended
Graft20-1715 4mm diameter, 3mm20-1716 4mm diameter, 5mm20-1717 4mm diameter, 7mm
Curved20-1620 7.5mm20-1621 9.5mm20-1622 11.5mm
Bayonet 30˚Curved Forward20-1665 7mmR20-1666 9mmR20-1670 7mmL20-1671 9mmL
80-1842 - TRAY #2 INCLUDES:
80-1843 - TRAY #3 INCLUDES:
Straight20-1600 5mm20-1601 7mm20-1602 9mm20-1603 12mm20-1604 15mm20-1605 20mm20-1606 25mm
Bayonet20-1655 5mm20-1656 7mm
20-1657 9mm20-1658 12mm20-1659 15mm20-1660 20mm20-1661 25mm
Super Bayonet20-1675 5mm20-1676 7mm20-1677 9mm20-1678 12mm20-1679 15mm
20-1680 20mm20-1681 25mm
30o Forward Angle20-1648 7mm20-1649 9mm20-1650 12mm20-1651 15mm
Sideward Angle20-1641 7mm20-1642 9mm
20-1643 12mm20-1644 15mm
Slightly Curved20-1610 8mm20-1611 10mm20-1612 12mm20-1613 14mm20-1614 16mm20-1615 20mm
CLIP MICROCARE TRAY SYSTEM
Sterilizing/Storage trays, made of lightweight ULTEM®, contain soft rubber bars to hold individual clips. Code numbers and drawingsof clips appear on bottom of tray. Rubber holders on cover secures appliers.
Product Code Size/Description
80-1841 Tray #1, 12 1/2” x 7” x 2” (33cm x 18cm x 5cm)
80-1842 Tray #1, 12 1/2” x 7” x 2” (33cm x 18cm x 5cm)
80-1843 Tray #1, 12 1/2” x 7” x 2” (33cm x 18cm x 5cm)
80-1835 Mini Clip Tray For #6 and #7 Mini Clips and Appliers
80-1840 AVM Micro Clip Tray For AVM Micro Clips andAppliers
80-1844 Graft Clip Tray For Graft Clips
80-1845 Temporary Clip Tray For #6 and #7 Temporary Clipsand Appliers
80-1838 UNIVERSAL Mini Clip Tray For CODMAN andCompetitive aneurysm clips and appliers
For more information, contact your CODMAN Sales Representative • For product information, call (800) 225-0460 • www.codman.com
80-1841 - TRAY #1 INCLUDES:
482848.Q7:482848.Q7 5/13/08 9:13 AM Page 21
For more information, contact your Codman Sales Representative • For product information, call (800) 225-0460 • www.codman.com22
P R O D U C T C O D E I N D E X
20-1025 . . . . . 520-1032 . . . . . 520-1034 . . . . . 520-1035 . . . . . 520-1037 . . . . . 520-1038 . . . . . 520-1039 . . . . . 5
20-1600 . . . . 1120-1601 . . . . 1120-1602 . . . . 1120-1603 . . . . 1120-1604 . . . . 1120-1605 . . . . 1120-1606 . . . . 1120-1610 . . . . 1120-1611 . . . . 1120-1612 . . . . 1120-1613 . . . . 1120-1614 . . . . 1120-1615 . . . . 1120-1620 . . . . 1120-1621 . . . . 1120-1622 . . . . 1120-1626 . . . . 1120-1627 . . . . 1120-1628 . . . . 1120-1629 . . . . 1120-1635 . . . . 1120-1636 . . . . 1120-1637 . . . . 1120-1641 . . . . 1220-1642 . . . . 1220-1643 . . . . 1220-1644 . . . . 1220-1648 . . . . 1220-1649 . . . . 1220-1650 . . . . 1220-1651 . . . . 1220-1655 . . . . 1220-1656 . . . . 12
20-1657 . . . . 1220-1658 . . . . 1220-1659 . . . . 1220-1660 . . . . 1220-1661 . . . . 1220-1665 . . . . 1220-1666 . . . . 1220-1670 . . . . 1220-1671 . . . . 1220-1675 . . . . 1320-1676 . . . . 1320-1677 . . . . 1320-1678 . . . . 1320-1679 . . . . 1320-1680 . . . . 1320-1681 . . . . 1320-1682 . . . . 1320-1683 . . . . 1320-1684 . . . . 1320-1685 . . . . 1320-1686 . . . . 1320-1687 . . . . 1320-1688 . . . . 1320-1689 . . . . 1320-1690 . . . . 1320-1691 . . . . 1320-1692 . . . . 1320-1693 . . . . 1320-1694 . . . . 1320-1695 . . . . 1320-1696 . . . . 1320-1697 . . . . 1320-1698 . . . . 1320-1699 . . . . 13
20-1700 . . . . 1420-1701 . . . . 1420-1702 . . . . 1420-1703 . . . . 1420-1704 . . . . 1420-1705 . . . . 14
20-1715 . . . . 1420-1715 . . . . 2020-1716 . . . . 1420-1716 . . . . 2020-1717 . . . . 1420-1717 . . . . 2020-1718 . . . . 1420-1719 . . . . 1420-1720 . . . . 1420-1721 . . . . 1420-1722 . . . . 1420-1723 . . . . 1420-1724 . . . . 1420-1725 . . . . 1420-1726 . . . . 1420-1727 . . . . 1520-1728 . . . . 1520-1729 . . . . 1520-1730 . . . . 1520-1731 . . . . 1520-1732 . . . . 1520-1733 . . . . 1520-1734 . . . . 1520-1735 . . . . 1520-1736 . . . . 1520-1740 . . . . 1520-1741 . . . . 1520-1742 . . . . 1520-1745 . . . . 1520-1746 . . . . 1520-1747 . . . . 1520-1750 . . . . 1520-1751 . . . . 1520-1752 . . . . 1520-1760 . . . . 1920-1761 . . . . 1920-1762 . . . . 1920-1763 . . . . 1920-1764 . . . . 1920-1765 . . . . 19
20-1766 . . . . 1920-1767 . . . . 1920-1768 . . . . 1920-1769 . . . . 1920-1770 . . . . 2020-1771 . . . . 2020-1772 . . . . 2020-1773 . . . . 20
20-1801 . . . . 1620-1802 . . . . 1620-1803 . . . . 1620-1804 . . . . 1620-1805 . . . . 1620-1821 . . . . 1820-1822 . . . . 1820-1823 . . . . 1820-1824 . . . . 1820-1825 . . . . 1820-1826 . . . . 1820-1827 . . . . 1820-1828 . . . . 1820-1829 . . . . 1820-1831 . . . . 1820-1832 . . . . 1820-1833 . . . . 1820-1834 . . . . 1820-1835 . . . . 1820-1836 . . . . 1820-1837 . . . . 1820-1838 . . . . 1820-1839 . . . . 1820-1850 . . . . 1720-1851 . . . . 1720-1852 . . . . 1720-1853 . . . . 1720-1854 . . . . 1720-1855 . . . . 1820-1856 . . . . 1820-1860 . . . . 1920-1861 . . . . 19
20-1862 . . . . 1920-1863 . . . . 1920-1864 . . . . 1920-1865 . . . . 1920-1866 . . . . 1920-1867 . . . . 1920-1868 . . . . 1920-1869 . . . . 1920-1870 . . . . 1920-1871 . . . . 1920-1872 . . . . 1920-1873 . . . . 1920-1874 . . . . 19
20-5115 . . . . . 520-5117 . . . . . 520-5120 . . . . . 520-5203 . . . . 2020-5205 . . . . 2020-5206 . . . . 20
26-1221 . . . . . 326-1222 . . . . . 326-1223 . . . . . 326-1229 . . . . . 326-1230 . . . . . 326-1231 . . . . . 326-1246 . . . . . 326-1247 . . . . . 3
26-5000 . . . . . 926-5000 . . . . . 926-5001 . . . . . 926-5002 . . . . . 926-5003 . . . . . 926-5003 . . . . . 926-5004 . . . . . 926-5004 . . . . . 926-5007 . . . . . 926-5007 . . . . . 926-5008 . . . . . 926-5008 . . . . . 9
Product Code Page Product Code Page Product Code Page Product Code Page Product Code Page
175724.Q7:175724.Q7 3/10/08 12:38 PM Page 22
26-5009 . . . . . 926-5009 . . . . . 926-5012 . . . . . 926-5015 . . . . . 926-5030 . . . . . 926-5040 . . . . . 9
43-1030 . . . . . 643-1032 . . . . . 643-1050 . . . . . 443-1060 . . . . . 4
80-1396 . . . . . 280-1397 . . . . . 280-1399 . . . . . 2
80-1400 . . . . . 280-1401 . . . . . 280-1402 . . . . . 280-1403 . . . . . 280-1404 . . . . . 280-1406 . . . . . 280-1407 . . . . . 280-1408 . . . . . 280-1409 . . . . . 280-1449 . . . . . 280-1450 . . . . . 280-1451 . . . . . 280-1452 . . . . . 280-1453 . . . . . 280-1454 . . . . . 280-1455 . . . . . 280-1456 . . . . . 280-1457 . . . . . 280-1460 . . . . . 4
80-1835 . . . . 2180-1838 . . . . 2180-1840 . . . . 2180-1841 . . . . 2180-1842 . . . . 2180-1843 . . . . 2180-1844 . . . . 2180-1845 . . . . 21
Product Code Page Product Code Page Product Code Page Product Code Page Product Code Page
N E U R O D I S P O S A B L E S C A T A L O GINDEX
23For more information, contact your CODMAN Sales Representative • For product information, call (800) 225-0460 • www.codman.com
175724.Q7:175724.Q7 3/10/08 12:38 PM Page 23
For more information, contact your Codman Sales Representative • For product information, call (800) 225-0460 • www.codman.com24
N O T E S
175724.Q7:175724.Q7 3/10/08 12:38 PM Page 24
N E U R O D I S P O S A B L E S C A T A L O GN
OT
ES
25For more information, contact your CODMAN Sales Representative • For product information, call (800) 225-0460 • www.codman.com
175724.Q7:175724 3/7/08 5:52 PM Page 25
N E U R O D I S P O S A B L E S C A T A L O GN
OT
ES
25For more information, contact your CODMAN Sales Representative • For product information, call (800) 225-0460 • www.codman.com
175724.Q7:175724.Q7 3/10/08 12:38 PM Page 25
3 2 5 P a r a m o u n t D r i v e , R a y n h a m , M A 0 2 7 6 7 • ( 5 0 8 ) 8 8 0 - 8 1 0 0
PLC-20-001 05/08 JC/UM
CODMAN® is a registered trademark of Codman & Shurtleff, Inc.
BICOL® is a registered trademark of Ethicon, Inc.
CRANIOPLASTIC® is a registered trademark of DePuy International Limited Corporation.
ANEUROPLASTIC® is a registered trademark of DePuy International.
For more information, contact your CODMAN Sales Representative
For product information, call (800) 225-0460 • www.codman.com©2008 Codman & Shurtleff, Inc. All rights reserved.
482848.Q7:482848.Q7 6/4/08 7:32 AM Page 26