SS-340D
PRODUCT SPECIFICATIONS
www.goodmanmfg.com 8/04Supercedes 5/04
Split SystemHeat Pump
The CPLJ split system heat pump is designed for ground-level or rooftop mount
application.
CPLJ SERIES12 SEER
1½ to 5 Ton
Air Handler and Coil Compatibilities• ARUF, ARPT and AEPT multi-position electric heat
air handlers• ARPF dedicated downflow electric heat air handler• AWB vertical wall-mounted electric heat air handler• AH vertical wall-mounted hydronic heat air handler• AC ceiling-mounted electric heat air handler• ACHP ceiling-mounted hydronic heat air handler• MBR/MBE modular blower• CA, CH and H indoor coils
Accessories• Standard Room Thermostat with 1-stage cool/2-
stage heat (HPT18-60)• Digital Room Thermostat with 1-stage cool/2-stage
heat (CHTP18-60HD)• Outdoor Lockout Thermostat/Emergency Heat
Relay Kit for staging electric heat (OT/EHR18-60)• Outdoor Thermostat (OT18-60); required for all
heat pumps if outdoor ambient temperature is 0˚F with 50% or higher relative humidity
Standard Features• Energy-efficient compressor with internal high-
pressure relief• Louvered guard protects coil from damage and adds
strength to unit• Bottom pan rails elevate unit above slab• Quiet operating top discharge• Totally enclosed, permanently lubricated
condenser motor• Copper tube, aluminum fin coil• Brass liquid and suction service valves with
sweat connections• Fully charged for 15’ of tubing length• Factory-installed bi-flow liquid line filter drier• Discharge line muffler• Suction line accumulator• Check-flowrater expansion device• Time-initiated, temperature-terminate defrost• Low-pressure control for loss of charge protection• Crankcase heater (where indicated)
Cabinet Construction• Polyester powder paint provides premium durability
and improved UV protection• Heavy-gauge, zinc-clad, G90 galvanized steel• When properly anchored, meets the 2001 Florida
Building Code unit integrity requirements for hurricane-type winds
PRODUCT SPECIFICATIONS
2
Electrical Data
1) Wire size should be determined in accordance with National Electrical Codes; extensive wire runs will require larger wire sizes2) May use fuses or HACR type Circuit Breakers of the same size as noted3) The -*B models are painted Architectural Gray. All other models are painted Bahama Beige.* With Crankcase Heat**Uses Scroll Compressor
Specifications
ModelService Valve
Type ApproximateShipping Weight (pounds)Liquid Suction
CPLJ18-1A/-1B 3/8” 3/4” Sweat 127CPLJ24-1A/-1B 3/8” 3/4” Sweat 147CPLJ30-1A/-1B 3/8” 3/4” Sweat 142CPLJ36-1A/-1B 3/8” 3/4” Sweat 152 CPLJ42-1A/-1B 3/8” 7/8” Sweat 162CPLJ48-1A/-1B 3/8” 7/8” Sweat 178CPLJ60-1A/-1B 3/8” 7/8” Sweat 182
Model Volts Ph Hz Minimum Circuit Amps1
Maximum Overcurrent Protection2
Minimum Volts
Maximum Volts
Compressor Condenser Fan
RLA LRA FLA HP
*CPLJ18-1A/-1B 208/230 1 60 11.7 20 197 253 8.6 49 .9 1/6*CPLJ24-1A/-1B 208/230 1 60 13.2 20 197 253 9.8 56.0 .9 1/6**CPLJ30-1A/-1B 208/230 1 60 18.0 30 197 253 13.5 72.5 1.1 1/6**CPLJ36-1A/-1B 208/230 1 60 19.3 30 197 253 14.7 83.0 .9 1/6**CPLJ42-1A/-1B 208/230 1 60 24.8 40 197 253 18.4 95.0 1.8 1/4**CPLJ48-1A/-1B 208/230 1 60 24.7 40 197 253 18.3 109.0 1.8 1/4**CPLJ60-1A/-1B 208/230 1 60 33.8 50 197 253 25.0 148.0 2.5 1/3
3
PRODUCT SPECIFICATIONS
Dimensions
ELEVATED CHANNEL
ADDITIONAL 1-1/2“
LIQUID CONN.
SMALL CHASSIS = 23" MEDIUM CHASSIS = 29"
CPLJ24, 30 = 25’’ CPLJ18 = 32.5’’
CPLJ42 = 37.5’’ CPLJ48, 60 = 40’’
7/8" DIA. CONTROL
CPLJ36 = 30’’
1-1/8" DIA. POWER
SUCTION CONN.
SMALL CHASSIS = 23’’ MEDIUM CHASSIS = 29’’
SMALL CHASSIS
MEDIUM CHASSIS
PRODUCT SPECIFICATIONS
4
Performance Ratings
Model Evaporator CoilTotal
Cooling BTUH1
Sensible Cooling BTUH
BTUH @75 ºF/63 ºF to 95 ºF2 Cooling
SEER3Cooling
EER4
Heating BTUH @
47°F
HeatingCOP @ 47ºF
Heating BTUH @
17ºF
Heating COP @17ºF
Heating HSPF5 Decibels
Total Sensible
CPLJ18-1A/-1B
AC18-XXAC24-XXARUF018AWB18-XXAWB24-XX
U/UC32+EEP6
HT3236/H36F+EEPARPF036/ARPT032/ARUF032
AEPT030CA*F030*2*+EEPCHPF030A2*+EEP
16,40016,80017,00017,00017,40018,00018,00018,00018,00018,00018,000
12,30012,60012,70012,70013,10014,20014,20014,20014,20014,20014,200
15,50015,80016,00016,00016,40017,00017,00017,00017,00017,00017,000
11,80012,00012,20012,20012,60013,70013,70013,70013,70013,70013,700
11.5012.0011.0011.0012.0012.0012.0012.0013.0012.0012.00
10.5011.0010.0010.0011.0011.0011.0011.0012.0011.0011.00
16,00016,40017,00017,00017,40018,00018,00018,00018,00018,00018,000
2.803.003.003.003.003.503.503.503.503.503.50
9,0009,4009,4009,4009,60010,00010,00010,00010,00010,00010,000
2.002.002.002.002.002.202.202.202.202.202.20
7.007.007.007.007.507.307.307.507.807.307.30
72
CPLJ24-1A/-1B
AC24-XXAC30-XX
AWB24-XXARPT024/ARUF024
U/UC32+EEPU/UC42+EEP
HT3236/H36F+EEPAWB36-XX
ARPF036/ARPT032/ARUF032ARPT042/ARUF042
AEPT030CA*F030*2*+EEPCA*F042*2*+EEPCHPF030A2*+EEP
21,20022,00022,40022,40023,00023,00023,00023,00023,00023,00023,00023,00023,00023,000
15,90016,50016,80016,80018,00018,00018,00018,00018,00018,00018,00018,00018,00018,000
20,00020,70021,10021,10021,70021,70021,70021,70021,70021,70021,70021,70021,70021,700
15,50016,00016,40016,40017,40017,40017,40017,40017,40017,40017,40017,40017,40017,400
11.5012.0011.5011.5012.0012.0012.0012.0012.0012.0013.0012.0012.0012.00
10.5011.0010.5010.5011.0011.0011.0011.0011.0011.0012.0011.0011.0011.00
20,20021,00022,00022,00023,00023,00023,00023,00023,00023,00023,00023,00023,00023,000
2.802.803.003.003.303.303.303.303.303.303.303.303.303.30
11,80012,00012,10012,10013,60013,60013,60013,60013,60013,60013,60013,60013,60013,600
2.002.202.202.202.602.602.602.602.602.602.602.602.602.60
7.007.007.007.007.507.507.507.507.807.808.107.507.507.50
73
CPLJ30-1A/-1B
AC30-XXAC36-XX
AWB30-XXARUF030
HT3236/U/UC32+EEPU/UC42+EEP
HT4248/H36F+EEPAWB36-XX
ARPF036/ARPT032/ARUF032ARPT042/ARUF042
AEPT030AEPT036
CA*F030*2*+EEPCA*F042*2*+EEPCHPF030A2*+EEPCHPF042B2*+EEP
27,00027,40027,20027,20029,00029,00029,00029,00029,00029,00029,00030,00029,00029,00029,00029,000
20,20020,50020,40020,40021,60021,60021,60021,60021,60021,60021,60022,30021,60021,60021,60021,600
24,60025,00024,80024,80027,40027,40027,40027,40027,40027,40026,80029,30027,40027,40027,40027,400
18,90019,10019,10019,10020,70020,70020,70020,70020,70020,70021,20019,00020,70020,70020,70020,700
11.5012.0011.3011.3012.0012.0012.0012.0012.0012.0012.5013.0012.0012.0012.0012.00
10.5011.0010.5010.5011.0011.0011.0011.0011.0011.0011.5012.0011.0011.0011.0011.00
26,00026,40027,00027,00029,40029,40029,40029,40029,40029,40029,40030,00029,40029,40029,40029,400
2.802.803.003.003.303.303.303.303.303.303.303.503.303.303.303.30
14,00014,60014,80014,60017,00017,00017,00017,00017,00017,00017,00018,00017,00017,00017,00017,000
2.202.202.202.202.402.402.402.402.402.402.402.402.402.402.402.40
7.007.007.007.007.507.507.507.507.507.507.807.807.507.507.507.50
80
1) Certified per ARI 240 @ 80 °F/67 °F/95 °F2) TVA Rating3) Seasonal Energy Efficiency Ratio4) Energy Efficiency Ratio @ 80 °F/67 °F/95 °F5) HSPF = Heating Seasonal Performance Factor6) Order the EEP from the Service Department using Part No. B13707-38 or new Solid State Board B13707-35S. Part No. B13707-38 is not
interchangeable with B13707-35S.When mix-matching outdoor and indoor units, the indoor unit check-flowrator must match the outdoor unit size.See the AR series air handler for coil instructions.
5
PRODUCT SPECIFICATIONS
Model Evaporator CoilTotal
Cooling BTUH1
Sensible Cooling BTUH
BTUH @75 ºF/63 ºF to 95 ºF2 Cooling
SEER3Cooling
EER4
Heating BTUH @
47°F
HeatingCOP @ 47ºF
Heating BTUH @
17ºF
Heating COP @17ºF
Heating HSPF5 Decibels
Total Sensible
CPLJ36-1A/-1B
AC36-XXAWB36-XX/ARPT036/ARUF036
U/UC42+EEP6
HT4248/H49F+EEPARPT042/ARUF042
AEPT036ARPF048
CA*F042*2*+EEPCHPF042B2*+EEP
32,00033,00034,00034,00034,00035,00035,00034,00034,000
23,00023,80024,50024,50024,50025,90025,90024,50024,500
30,20031,15032,10032,10032,10034,00034,00032,10032,100
24,00024,90023,30023,30023,30024,60024,60023,30023,300
11.0011.3012.0012.0012.0013.0012.0012.0012.00
10.0010.3011.0011.0011.0012.0011.0011.0011.00
31,00033,00035,00035,00035,00035,00035,00035,00035,000
2.803.203.503.503.503.503.503.503.50
17,00019,00020,00020,00020,00020,00020,00020,00020,000
2.002.102.302.302.302.302.302.302.30
7.007.507.807.807.808.007.807.807.80
80
CPLJ42-1A/-1B
ARPT042/ARUF042U/UC60+EEP
HT61/H61F+EEPARPF048/ARPT049/ARUF049
AEPT060-00A-1CA*F060*2*+EEPCHPF060D2*+EEP
38,50040,00040,00040,00041,00040,00040,000
27,60030,40030,40030,40031,00030,40030,400
36,20037,80037,80037,80037,80037,80037,800
29,30029,30029,00029,30029,90029,30029,300
11.3012.0012.0012.0013.0012.0012.00
10.3011.0011.0011.0012.0011.0011.00
38,50040,00040,00040,00040,00040,00040,000
3.303.503.503.503.503.503.50
21,00022,40022,40022,40023,00022,40022,400
2.102.302.302.302.302.302.30
7.508.008.008.008.308.008.00
80
CPLJ48-1A/-1B
ARUF048ARPT049/ARUF049
U/UC60+EEPHT61/H61F+EEP
AEPT060ARPF060/ARPT061/ARUF061
CA*F060*2*+EEPCHPF060D2*+EEP
44,00044,00044,00044,00046,00046,00044,00044,000
32,50032,50032,50032,50035,00035,00032,50032,500
41,50041,50041,50041,50043,40043,40041,50041,500
31,00031,00031,00031,00033,60033,60031,00031,000
11.5012.0012.0012.0012.5012.0012.0012.00
10.5011.0011.0011.0011.5011.0011.0011.00
44,00045,00045,00045,00046,00046,00045,00045,000
3.303.503.503.503.603.603.503.50
24,00025,00025,00025,00027,00027,00025,00025,000
2.202.302.302.302.402.402.302.30
7.508.008.008.008.508.008.008.00
80
CPLJ60-1A/-1B
ARUF060U/UC62+EEP
ARPF060/ARPT061/ARUF061HT61/U/UC61+EEP
H61F+EEPAEPT060
CA*F061*2*+EEPCHPF060D2*+EEP
55,00055,00056,00056,00056,00056,00056,00056,000
39,60039,60040,30040,30040,30040,30040,30040,300
51,90051,90052,60052,60052,60052,60052,60052,600
37,00037,00037,70037,70037,70037,70037,70037,700
11.3011.5012.0012.0012.0012.0012.0012.00
10.3010.5011.0011.0011.0011.0011.0011.00
55,00055,00056,00056,00056,00056,00056,00056,000
3.203.203.303.303.303.303.303.30
30,00030,00031,00031,00031,00031,00031,00031,000
2.102.102.302.302.302.302.302.30
7.507.508.008.008.008.508.008.00
80
Performance Ratings (cont.)
1) Certified per ARI 240 @ 80 °F/67 °F/95 °F2) TVA Rating3) Seasonal Energy Efficiency Ratio4) Energy Efficiency Ratio @ 80 °F/67 °F/95 °F5) HSPF = Heating Seasonal Performance Factor6) Order the EEP from the Service Department using Part No. B13707-38 or new Solid State Board B13707-35S. Part No. B13707-38 is not
interchangeable with B13707-35S.When mix-matching outdoor and indoor units, the indoor unit check-flowrator must match the outdoor unit size.
PRODUCT SPECIFICATIONS
6
Heating Performance Expanded Ratings @ 70 °F Indoor Ambient
7
PRODUCT SPECIFICATIONS
Heating Performance Expanded Ratings @ 70 °F Indoor Ambient (cont.)
PRODUCT SPECIFICATIONS
Goodman Manufacturing Company, L.P., reserves the right to discontinue, or change at any time, specifications or designs without notice or without incurring obligations.Copyright © 2004 Goodman Manufacturing Company, L.P. • Houston, Texas • Printed in the USA. • Goodman® brand products are made proudly in the USA.
8