Cover Page

Vendor Name: Valvitalia S.p.A.

Equipment/Item:

Pneumatic Actuated Ball Valves

Vendor Document Title: VLT/VLT AUTOM. DATA SHEETS

Vendor Document Number:

Penspen Document Number:

EPC Compression Station & Facilities at 103A

Page 3: Cover pneumatic valves.pdf · 2013. 9. 10. · API 598/API 6D API 6FA ANSI/FCI Leakage Class High Tightness Class VI Fire Test Local Reset Yes TESTS Hydrostatic / Pneumatic ... Area

CLIENT ITEM

VLT. ITEM TAG NO. STAT. VALVE TYPE VALVE

SIZE (")VALVE CLASS

END CONN.

OPERATOR NAME

OPERATOR TYPE OPERATOR MODEL SHEET

NO.

1 1 62-XV-6102 103A Side entry ball valve 20 x 16 900 RF Valvitalia Pneumatic LPS-16-530-CM29-FC 32 2 62-XV-6202 103A Side entry ball valve 20 x 16 900 RF Valvitalia Pneumatic LPS-16-530-CM29-FC 43 3 62-XV-6901 103A Side entry ball valve 24 X 20 600 RF Valvitalia Pneumatic LPS-16-530-CM29-FC 54 4 62-XV-6010 103A Side entry ball valve 24 X 20 600 RF Valvitalia Pneumatic LPS-16-530-CM29-FC 65 5 62-XV-6020 103A Side entry ball valve 24 X 20 600 RF Valvitalia Pneumatic LPS-16-530-CM29-FC 76 6 62-XV-6100 103A Side entry ball valve 24 X 20 600 RF Valvitalia Pneumatic LPS-16-530-CM29-FC 87 7 62-XV-6200 103A Side entry ball valve 24 X 20 600 RF Valvitalia Pneumatic LPS-16-530-CM29-FC 98 8 62-XV-6085 103A Side entry ball valve 36 X 30 900 RF Valvitalia Pneumatic LPS-20-940-CM34-FC 10

10 9 63-XV-6010 PRMS Side entry ball valve 18 X 14 600 RF Valvitalia Pneumatic LPS-13-530-CM25-FC 1111 10 63-XV-6020 PRMS Side entry ball valve 18 X 14 600 RF Valvitalia Pneumatic LPS-13-530-CM25-FC 1212 11 63-XV-6225 PRMS Side entry ball valve 18 X 14 600 RF Valvitalia Pneumatic LPS-13-530-CM25-FC 1313 12 63-XV-6604 PRMS Side entry ball valve 20 X 16 600 RF Valvitalia Pneumatic LPS-13-530-CM25-FC 1414 13 63-XV-6602 PRMS Side entry ball valve 36 X 30 600 RF Valvitalia Pneumatic LPS-20-840-CM33-FC 1515 14 63-XV-6004 PRMS Side entry ball valve 36 X 30 600 RF Valvitalia Pneumatic LPS-20-940-CM34-FC 1616 15 63-XV-6301 PRMS Side entry ball valve 36 X 30 600 RF Valvitalia Pneumatic LPS-20-940-CM34-FC 179 18 62-XV-6081 103A Side entry ball valve 36 X 30 900 RF Valvitalia Pneumatic LPS-20-940-CM34-FC 181 19 62-XV-6107 103A Side entry ball valve 20 x 16 900 RF Valvitalia Pneumatic LPS-16-530-CM29-FC 196 20 62-XV-6108 103A Side entry ball valve 24 X 20 600 RF Valvitalia Pneumatic LPS-16-530-CM29-FC 202 21 62-XV-6207 103A Side entry ball valve 20 x 16 900 RF Valvitalia Pneumatic LPS-16-530-CM29-FC 217 22 62-XV-6208 103A Side entry ball valve 24 X 20 600 RF Valvitalia Pneumatic LPS-16-530-CM29-FC 22

20 23 62-XV-6902 103A Side entry ball valve 2 X 1,5 600 RF Valvitalia Pneumatic LPS-05-135-CM04 2321 24 62-XV-6012 103A Side entry ball valve 2 X 1,5 600 RF Valvitalia Pneumatic LPS-05-135-CM04 2422 25 62-XV-6074 103A Side entry ball valve 6 X 4 600 RF Valvitalia Pneumatic LPS-07-280-CM12 2523 26 62-XV-6075 103A Side entry ball valve 2 X 1,5 600 RF Valvitalia Pneumatic LPS-05-135-CM04 2624 27 62-XV-6022 103A Side entry ball valve 2 X 1,5 600 RF Valvitalia Pneumatic LPS-05-135-CM04 2725 28 62-XV-6101 103A Side entry ball valve 2 X 1,5 600 RF Valvitalia Pneumatic LPS-05-135-CM04 2826 29 62-XV-6103 103A Side entry ball valve 2 X 1,5 900 RF Valvitalia Pneumatic LPS-05-135-CM04 2927 30 62-XV-6201 103A Side entry ball valve 2 X 1,5 600 RF Valvitalia Pneumatic LPS-05-135-CM04 3028 31 62-XV-6203 103A Side entry ball valve 2 X 1,5 900 RF Valvitalia Pneumatic LPS-05-135-CM04 3129 32 62-XV-6086 103A Side entry ball valve 2 X 1,5 900 RF Valvitalia Pneumatic LPS-05-135-CM04 3231 34 62-XV-6972 103A Side entry ball valve 6 600 RF Valvitalia Pneumatic LPS-07-320-CM12 3332 35 62-XV-6076 103A Side entry ball valve 6 600 RF Valvitalia Pneumatic LPS-07-320-CM12 3433 36 62-XV-6104 103A Side entry ball valve 2 900 RF Valvitalia Pneumatic LPS-05-200-CM07 3534 37 62-XV-6204 103A Side entry ball valve 2 900 RF Valvitalia Pneumatic LPS-05-200-CM07 3635 38 62-XV-6089 103A Side entry ball valve 2 X 1,5 900 RF Valvitalia Pneumatic LPS-05-135-CM04 3736 39 62 SPARE 103A Side entry ball valve 4 900 RF Valvitalia Pneumatic LPS-07-280-CM12 N/A37 40 62 SPARE 103A Side entry ball valve 3 900 RF Valvitalia Pneumatic LPS-07-235-CM08B N/A38 41 63-XV-6003 PRMS Side entry ball valve 2 X 1,5 600 RF Valvitalia Pneumatic LPS-05-135-CM04 3839 42 63-XV-6011 PRMS Side entry ball valve 2 X 1,5 600 RF Valvitalia Pneumatic LPS-05-135-CM04 3940 43 63-XV-6021 PRMS Side entry ball valve 2 X 1,5 600 RF Valvitalia Pneumatic LPS-05-135-CM04 4041 44 63-XV-6304 PRMS Side entry ball valve 2 X 1,5 600 RF Valvitalia Pneumatic LPS-05-135-CM04 4142 45 63-XV-6226 PRMS Side entry ball valve 2 X 1,5 600 RF Valvitalia Pneumatic LPS-05-135-CM04 4243 46 63-XV-6603 PRMS Side entry ball valve 2 X 1,5 600 RF Valvitalia Pneumatic LPS-05-135-CM04 4344 47 63-XV-6605 PRMS Side entry ball valve 2 X 1,5 600 RF Valvitalia Pneumatic LPS-05-135-CM04 4445 48 63 SPARE PRMS Side entry ball valve 2 600 RF Valvitalia Pneumatic LPS-05-160-CM06 N/A46 49 63-XV-6600 PRMS Side entry ball valve 4 600 RF Valvitalia Pneumatic LPS-07-280-CM12 4547 50 63-XV-6601 PRMS Side entry ball valve 2 600 RF Valvitalia Pneumatic LPS-05-160-CM06 4648 51 63-XV-6101 PRMS Side entry ball valve 4 X 3 600 RF Valvitalia Pneumatic LPS-07-235-CM08B 4749 52 63-XV-6103 PRMS Side entry ball valve 4 X 3 600 RF Valvitalia Pneumatic LPS-07-235-CM08B 4851 54 63-XV-6203 PRMS Side entry ball valve 3 600 RF Valvitalia Pneumatic LPS-05-235-CM09 4952 55 63-XV-6403 PRMS Side entry ball valve 2 600 RF Valvitalia Pneumatic LPS-05-160-CM06 5050 58 62-XV-6900 103A Side entry ball valve 6 600 RF Valvitalia Pneumatic LPS-07-320-CM12 5157 59 62-XV-6084 103A Side entry ball valve 6 900 RF Valvitalia Pneumatic LPS-99-230-SC5 5258 60 62-XV-6871 103A Side entry ball valve 2 300 RF Valvitalia Pneumatic LPS-05-160-CM06 5330 61 63-XV-6005 PRMS Side entry ball valve 3 600 RF Valvitalia Pneumatic LPS-05-235-CM09 54

INDEX

Page 1 of 53

Page 4: Cover pneumatic valves.pdf · 2013. 9. 10. · API 598/API 6D API 6FA ANSI/FCI Leakage Class High Tightness Class VI Fire Test Local Reset Yes TESTS Hydrostatic / Pneumatic ... Area

12345678910 Units Normal Shut-Off11 mmscfd 248.3-300 -

12 psig 779-132413 °F 130 -

14 psi -

15 psig16 °F -

17 Kg/m3 -

18 CP -

19 psi20 6321 6422 6523 6624 6725 6826 6927 7028 7129 7230 In 7331 Out 7432 7533 7634 7735 7836 7937 8038 8139 8240 8341 8442 8543 8644 8745 8846 8947 9048 9149 9250 9351 94 M20 x 1,552 95 N.A.53 9654 9755 98 4 Nos. 56 99 WESTLOCK 2649SBYN00042BEI-0057 10058 10159 10260 10361 10462 105

AC

TUA

TOR

Pipe Line Insulation

End

REGU

LATO

RSO

LEN

OID

VA

LVE

SPEC

IALS

/ A

CC

ESSO

RIE

S

LIM

IT S

WIT

CH

API 598/API 6D

API 6FAANSI/FCI Leakage Class High Tightness Class VIFire Test

Local Reset Yes

TEST

S

Hydrostatic / Pneumatic

24V DC @ 1AHydraulic Power Pack Not Required Enclosure Class / Material IP 67

Required, Local Contacts RatingPartial Stroking FacilityValve Control Panel Required, SS 316, IP 65 Mfr & Model- Pressure Switch N/A Quantity

EEx'd'/316 SSConduit Connection Size

- Relief Valve N/A Type Proximity Type, Hermetical Seal, DPDT- Capacity N/AAir Accumulator N/A Manual Reset

Other seal VITON AED + GRAPHITE Enclosure Class / Material

Valve OPENSeals VITON AED Voltage Rating 24VDC± 10%

ASTM A350 LF2 + ENP 0,001" Solenoid EnergisedSeat Ring Material

Mfr. & Model

87 psi g (6 barg)

ASCO NFET8327B202TRIM

Type Ball Filter Reg & Gauge

Stem/Trunnion 17-4-PH + ENP 0,001" Type & Material

N/A Regulator Pressure Range

62-SOV-6102A and 62-SOV-6102B

RequiredLine Filter

3/2 Way/316 SS

Relief Valve Set Pressure59,5 psi g (4,1 barg)

Size

Ball ASTM A350 LF2+0,001" ENP Tag Number

RB

N/ARated

Bolts / Nuts ASTM A193 Gr B7M / A194 Gr 2HM Process ConnectionRequired

Balanced/UnbalancedCharacteristic On-Off Valve Supply Pressure

Spiral Wound SS316L with Graphite Filler Mfr & Model1/2 " NPT (F)

Instrument Air

Type of Bonnet Standard Enclosure Material CS

Maxseal IFR4 1/2" NPT

Required (Mechanical)Packing Material PTFE or Equivalent Local Control Cabinet Stainless SteelLub & I so Valve Yes Local Position Indicator

Body/Bonnet Gasket

Not RequiredFlow Direction Bi-directional valve Max. stroke Time 1 Sec for Nominal inchEnd Ext/Matl Not Applicable Handwheel

20", RF, 900 lb Speed Control Yes

Fig Face Finish RF, Smooth Finish.ASME B16.5 Mechanical Limit Stop Yes

Liner Material/ID N/A Process Connection Top/Side Mounting20", RF, 900 lb On/Off Yes

Max. Press/Temp 1480 Psi / 300 °F Valve Run/Seating Torque 1792 / 2329 Nm13550 /4706 Nm

Body/Bonnet Matl ASTM A350 LF2 Maximum Shutoff DP 1338 psi

Inst. AirDouble block & bleed Required Air Failure position Fail Close

5155 Nm

VALV

E B

OD

Y/B

ON

NET

Type Ball Valve (Reduced Bore) Actuating Medium

Size 20" ASME Class 900 lb Valve Breakaway Torque

Mfr & Model 55 Actuator Break/Run Torque

Mfr & Model Valvitalia LPS-16-530-CM29

Critical Press Pc -

Spring Return, air piston operated.

300Fluid Density 44-78.3

LIN

E Line Size & thicknessIn 20" /14.27 mm WT TypeOut 20" /14.27 mm WT Spring Material Carbon Steel

Fluid Viscosity @ OP. TEMP 0.01 to 0.03

Inlet Temperature 130 125Max. Shutoff Differential Pressure 1338Design Pressure 1480Design Temperature

MinimumFlow Rate 300 0

Area Classification CLASS 1, ZONE 1, GAS GROUP HA, T3Start-Up Bypass Valve 62-XV-6103 (Refer Sheet 15)

SER

VIC

E C

ON

DIT

ION

S

Fluid Natural GasPhase Gas

Inlet Pressure 1338 775

Maximum

62-XV-6102PID Number 40227/PR/1/02/108

Function Unit Shut Down Valve

Service Compressor K-10 OutletLine NumberA/essel No. NG-102-20"-F40

GEN

ERA

L

ZUEITINA OIL COMPANY

Data Sheets for ESD and Blowdown Valves- 103A Area

DOC. NO. 2010-0111 REV 0 DATE 30/06/2010

Tag Number

Page 5: Cover pneumatic valves.pdf · 2013. 9. 10. · API 598/API 6D API 6FA ANSI/FCI Leakage Class High Tightness Class VI Fire Test Local Reset Yes TESTS Hydrostatic / Pneumatic ... Area

123456789

10 Units Normal Shut-Off11 mmscfd 248.3-300 -

12 psig 779-132413 °F 130 -

14 psi -

15 psig16 °F -

17 Kg/m3 -

18 CP -

19 psi20 6321 6422 6523 6624 6725 6826 6927 7028 7129 7230 In 7331 Out 7432 7533 7634 7735 7836 7937 8038 8139 8240 8341 8442 8543 8644 8745 8846 8947 9048 9149 9250 9351 94 M20 x 1,552 95 N.A.53 9654 9755 98 4 Nos.56 99 WESTLOCK 2649SBYN00042BEI-0057 10058 10159 10260 10361 10462 105

Line NumberA/essel No. NG-105-20"-F40

ZUEITINA OIL COMPANY

Data Sheets for ESD and Blowdown Valves- 103A Area

DOC. NO. 2010-0111

ServiceG

ENER

AL

Unit Shut Down Valve

REV 0 DATE 30/06/2010

Compressor K-20 Outlet

Area Classification CLASS 1, ZONE 1, GAS GROUP HA, T3Start-Up Bypass Valve 62-XV-6203(Refer Sheet 19)

Tag Number 62-XV-6202PID Number 40227/PR/1/02/109

Function

SER

VIC

E C

ON

DIT

ION

S

Fluid Natural GasPhase Gas

Maximum MinimumFlow Rate

Max. Shutoff Differential Pressure 1338

0Inlet Pressure 1338 775

300

Inlet Temperature 130 125

Fluid Density 44-78.3Fluid Viscosity @ OP. TEMP 0.01 to 0.03

Design Pressure 1480Design Temperature 300

LIN

E Line Size & thicknessIn 20" / 14.27 mm WT TypeOut 20" /14.27 mm WT Spring Material Carbon Steel

Mfr & Model Valvitalia LPS-16-530-CM29

Critical Press Pc -

Spring Return, air piston operated.

VALV

E B

OD

Y/B

ON

NET

Type Ball Valve (Reduced Bore) Actuating Medium

Size 20" ASME Class 900 lb Valve Breakaway Torque

Body/Bonnet Matl ASTM A350 LF2Mfr & Model

Double block & bleed Required Air Failure position Fail Close

Valve Run/Seating Torque 1792 / 2329 Nm5155 Nm

Inst. Air

Top/Side Mounting

55 Actuator Break/Run Torque 13550 /4706 NmMaximum Shutoff DP 1338 psi

Yes

20", RF, 900 lb On/Off Yes20", RF, 900 lb Speed Control Yes

Stainless Steel

Not RequiredFlow Direction Bi-directional valve Max. stroke Time 1 Sec for Nominal inchEnd Ext/Matl Not Applicable Handwheel

Enclosure Material

AC

TUA

TOR

Pipe Line Insulation

Local Control Cabinet

Mechanical Limit Stop

Liner Material/ID N/A Process Connection

Max. Press/Temp 1480 Psi / 300°F

RequiredSize RB

CSLub & I so Valve Yes Local Position Indicator Required (Mechanical)Type of Bonnet Standard

Process Connection 1/2" NPT (F)Body/Bonnet Gasket Spiral Wound SS316L with Graphite Filler Mfr & Model Maxseal IFR4 1/2" NPT

Line Filter Required

TRIM

Type Ball Filter Reg & Gauge

Characteristic

Mfr. & Model ASCO NFET8327B202

Instrument AirBalanced/Unbalanced N/A Regulator Pressure Range 59,5 psi g (4,1 barg)

On-Off Valve Supply Pressure

Stem/Trunnion 17-4-PH + ENP 0,001" Type & Material 3/2 Way/316 SS

87 psi g (6 barg)Ball ASTM A350 LF2+0,001" ENP Tag Number 62-SOV-6202A and 62-SOV-6202B

Relief Valve Set Pressure

EEx'd'/316 SSSeals VITON AED Voltage Rating 24VDC ± 10%Seat Ring Material ASTM A350 LF2 + ENP 0,001" Solenoid Energised Valve OPEN

Quantity

Conduit Connection SizeAir Accumulator N/A Manual Reset- Capacity- Relief Valve N/A Type Proximity Type, Hermetical Seal, DPDT

N/A

SOLE

NO

ID V

ALV

E

Other seal VITON AED + GRAPHITE Enclosure Class / Material

API 598/API 6DHigh Tightness Class VI

Required, SS 316, IP 65 Mfr & ModelPartial Stroking Facility Required, Local Contacts Rating

ANSI/FCI Leakage Class

Local Reset Yes

24V DC @ 1AHydraulic Power Pack Not Required Enclosure Class / Material IP 67

Fire TestTEST

S

Hydrostatic / Pneumatic

API 6FA

SPEC

IALS

/ A

CC

ESSO

RIE

S

LIM

IT S

WIT

CH

- Pressure Switch N/AValve Control Panel

EndRE

GULA

TORBolts / Nuts ASTM A193 Gr B7M / A194 Gr 2HM

Packing Material PTFE or Equivalent

Fig Face Finish RF, Smooth Finish.ASME B16.5

Rated N/A

Page 6: Cover pneumatic valves.pdf · 2013. 9. 10. · API 598/API 6D API 6FA ANSI/FCI Leakage Class High Tightness Class VI Fire Test Local Reset Yes TESTS Hydrostatic / Pneumatic ... Area

123456789

10 Units Normal Shut-Off11 mmscfd 250 -

12 psig 47013 °F 100 -

14 psi -

15 psig16 °F -

17 Kg/m3 -

18 CP -

19 psi20 6321 6422 6523 6624 6725 6826 6927 7028 7129 7230 In 7331 Out 7432 7533 7634 7735 7836 7937 8038 8139 8240 8341 8442 8543 8644 8745 8846 8947 9048 9149 9250 9351 94 M20 x 1,552 95 N.A.53 9654 9755 98 4 Nos.56 99 WESTLOCK 2649SBYN00042BEI-0057 10058 10159 10260 10361 10462 105

ZUEITINA OIL COMPANY

Data Sheets for ESD and Blowdown Valves- 103A Area

DOC. NO. 2010-0111 REV 0 DATE 30/06/2010

62-XV-6901PID Number 40227/PR/1/02/002Service Al Faregh Stream to 103A

GEN

ERA

LTag Number

Area Classification CLASS 1, ZONE 1, GAS GROUP NA, T3Start-Up Bypass Valve 62-XV-6902 (Refer Sheet 5)

Line Number/Vessel No. NG-001-24"-E41Function Shut Down Valve

SER

VIC

E C

ON

DIT

ION

S

Fluid Natural GasPhase Gas

Maximum MinimumFlow Rate 250

Inlet Temperature 100 98Max. Shutoff Differential Pressure 699

0Inlet Pressure 635 430

Fluid Density 25.2Fluid Viscosity @ OP. TEMP 0.01

Design Pressure 1360Design Temperature 200

Critical Press Pc -

LIN

E Line Size & ScheduleIn 24" /15.88 mm WT Type Spring Return, air piston operated.Out 24" /15.88 mm WT Spring Material Carbon Steel

2478 / 3221 Nm13550 /4706 Nm

Pipe Line Insulation N/A. Mfr & Model Valvitalia LPS-16-530-CM29

Inst. Air Fail Close5663 Nm

Max. Press/Temp 1360 Psi / 200°F

VALV

E B

OD

Y/B

ON

NET

Type Ball Valve (Reduced Bore) Actuating Medium

SizeDouble block & bleed Required Air Failure position

24" ASME Class 600 lb Valve Breakaway TorqueValve Run/Seating Torque

Body/Bonnet Matl ASTM A350 LF2 Maximum Shutoff DPMfr & Model 55 Actuator Break/Run Torque

Liner Material/ID N/A Process Connection Top/Side Mounting

End Conn.24", RF, 600 lb On/Off Yes24", RF, 600 lb YesSpeed Control

Fig Face Finish RF, Smooth Finish.ASME B16.5 Mechanical Limit Stop Yes

Lub & Iso Valve Yes Local Position Indicator

Flow Direction Bi-directional valve Max. stroke TimeType of Bonnet Standard Enclosure Material

End Ext/Matl Not Applicable Handwheel

Other seal

Stainless SteelBody/Bonnet Gasket Spiral Wound SS316L with Graphite Filler Mfr & Model Maxseal IFR4 1/2" NPT

RB

Packing Material

Line Filter

Bolts / Nuts

59,5 psi g (4,1 barg)On-Off Valve

ASTM A193 Gr B7M / A194 Gr 2HM

BallProcess ConnectionFilter Reg & Gauge Required

PTFE or Equivalent Local Control Cabinet

AC

TUA

TOR

1/2" NPT (F)

CS

Not Required

Required (Mechanical)

1 Sec for Nominal inch

699 psi

87 psi g (6 barg)Ball ASTM A350 LF2 + ENP 0,001" Tag Number 62-SOV-6901A and 62-SOV-6901B

REGU

LATO

R

Supply Pressure Instrument AirRequired

Rated

ASCO NFET8327B202Stem/Trunnion 17-4-PH + ENP 0,001" Type & Material 3/2 Way/ 316 SS

Mfr. & Model

Valve OPENSeals VITON AED Voltage Rating 24VDC±10%Seat Ring Material ASTM A350 LF2 + ENP 0,001"

Conduit Connection Size

- Relief Valve N/A Type

TRIM

Type

Solenoid Energised

Relief Valve Set PressureNANABalanced/Unbalanced Regulator Pressure Range

CharacteristicSize

24V DC @ 1A

SOLE

NO

ID V

ALV

E

VITON AED+GRAPHITE Enclosure Class EEx'd'

Manual Reset

Proximity Type, Hermetical Seal, DPDTN/A

Mfr & Model

- Capacity N/A

- Pressure Switch Quantity

Enclosure Class / Material IP 67

LIM

IT S

WIT

CH

Local Reset Yes

Partial Stroking Facility Required, Local Contacts Rating

TEST

S

Hydraulic Power Pack Not Required

SPEC

IALS

/ A

CC

ESSO

RIE

S

Air Accumulator N/A

Valve Control Panel Required, SS 316, IP 65

Hydrostatic / Pneumatic API 598/API 6DANSI/FCI Leakage Class High Tightness Class VI

API 6FAFire Test

Page 7: Cover pneumatic valves.pdf · 2013. 9. 10. · API 598/API 6D API 6FA ANSI/FCI Leakage Class High Tightness Class VI Fire Test Local Reset Yes TESTS Hydrostatic / Pneumatic ... Area

123456789

10 Units Normal Shut-Off11 mmscfd 250-300 -

12 psig 43013 °F 100 -

14 psi -

15 psig16 °F -

17 Kg/m3 -

18 CP -

19 psi20 6321 6422 6523 6624 6725 6826 6927 7028 7129 7230 In 7331 Out 7432 7533 7634 7735 7836 7937 8038 8139 8240 8341 8442 8543 8644 8745 8846 8947 9048 9149 9250 9351 94 M20 x 1,552 95 N.A.53 9654 9755 98 4 Nos.56 99 WESTLOCK 2649SBYN00042BEI-0057 10058 10159 10260 10361 10462 105

ZUEITINA OIL COMPANY

Data Sheets for ESD and Blowdown Valves- 103A Area

DOC. NO. 2010-0111 REV 0 DATE 30/06/2010

62-XV-6010PID Number 40227/PR/1/02/101Service Filter Seperator C-10 Inlet ESD Valve

GEN

ERA

LTag Number

Area Classification CLASS 1, ZONE 1, GAS GROUP HA, T3Start-Up Bypass Valve 62-XV-6012 (Refer Sheet 7)

Line NumberA/essel No. NG-005-24"-E41Function Shut Down Valve

SER

VIC

E C

ON

DIT

ION

S

Fluid Natural GasPhase Gas

Maximum MinimumFlow Rate 300

Inlet Temperature 101 95Max. Shutoff Differential Pressure 485

0Inlet Pressure 485 420

Fluid Density 25.2Fluid Viscosity @ OP. TEMP 0.01

Design Pressure 1360Design Temperature 200

LIN

E Line Size & thicknessIn 24" / 15.88 mm WT TypeOut 24" /15.88 mm WT Spring Material

Pipe Line Insulation

Size

Carbon SteelMfr & Model Valvitalia LPS-16-530-CM29

24" ASME Class 600 lb

Critical Press Pc -

Spring Return, air piston operated.

Valve Breakaway Torque 5626 Nm

Inst. AirDouble block & bleed Required Air Failure position Fail Close

VALV

E B

OD

Y/B

ON

NET

Type Ball Valve (Reduced Bore) Actuating Medium

Max. Press/Temp 1360 Psi / 200°F Valve Run/Seating Torque

Maximum Shutoff DP

On/Off

Fig Face Finish

2478 / 3221 NmMfr & Model 55 Actuator Break/Run Torque 13550 /4706 Nm

485 psiLiner Material/ID N/A Process Connection Top/Side MountingBody/Bonnet Matl ASTM A350 LF2

Yes24", RF, 600 lb Speed Control Yes

24", RF, 600 lb

End Ext/Matl Handwheel Not RequiredRF, Smooth Finish,ASME B16.5 Mechanical Limit Stop Yes

Not Applicable

Enclosure Material CS Flow Direction Bi-directional valve Max. stroke Time 1 Sec for Nominal inchType of Bonnet Standard

Required (Mechanical)Packing Material PTFE or Equivalent Local Control Cabinet Stainless SteelLub & Iso Valve Yes Local Position Indicator

AC

TUA

TOR

End

VITON AED+GRAPHITE

Process Connection 1/2 " NPT (F)Body/Bonnet Gasket Spiral Wound SS316L with Graphite Filler Mfr & Model Maxseal IFR4 1/2" NPT

RequiredInstrument Air

NA

TRIM

Type Ball

Characteristic On-Off Valve

Rated NA

Seat Ring Material ASTM A350 LF2 + ENP 0,001"

Balanced/Unbalanced

Line Filter

Relief Valve Set PressureRegulator Pressure Range 59,5 psi g (4,1 barg)Supply Pressure

Filter Reg & Gauge Required

87 psi g (6 barg)Ball ASTM A350 LF2 + ENP 0,001" Tag Number 62-SOV-6010A and 62-SOV-6010B

REGU

LATO

RBolts / Nuts ASTM A193 Gr B7M / A194 Gr 2HM

Other seal Enclosure Class / Material

Size RB

Stem/Trunnion 17-4-PH + ENP 0,001" Type & MaterialMfr. & Model

Seals VITON AED Voltage Rating 24VDC± 10%

Conduit Connection SizeAir Accumulator N/A Manual ResetSO

LEN

OID

VA

LVE

EEx'd'/316 SS

Valve OPENSolenoid Energised

ASCO NFET8327B2023/2 Way/316 SS

- Pressure Switch N/A

- Capacity N/AProximity Type, Hermetical Seal, DPDT

Contacts Rating 24V DC @ 1AValve Control Panel Required, SS 316, IP 65 Mfr & Model

Quantity- Relief Valve N/A Type

IP 67Local Reset YesHydraulic Power Pack Enclosure Class / MaterialNot Required

High Tightness Class VI

TEST

S

API 598/API 6DHydrostatic / Pneumatic

Fire Test API 6FAANSI/FCI Leakage Class

SPEC

IALS

/ A

CC

ESSO

RIE

S

LIM

IT S

WIT

CH

Partial Stroking Facility Required, Local

Page 8: Cover pneumatic valves.pdf · 2013. 9. 10. · API 598/API 6D API 6FA ANSI/FCI Leakage Class High Tightness Class VI Fire Test Local Reset Yes TESTS Hydrostatic / Pneumatic ... Area

123456789

10 Units Normal Shut-Off11 mmscfd 250-300 -

12 psig 43013 °F 10014 psi -

15 psig16 °F -

17 Kg/m3 -

18 CP -

19 psi20 6321 6422 6523 6624 6725 6826 6927 7028 7129 7230 In 7331 Out 7432 7533 7634 7735 7836 7937 8038 8139 8240 8341 8442 8543 8644 8745 8846 8947 9048 9149 9250 9351 94 M20 x 1,552 95 N.A.53 9654 9755 98 4 Nos.56 99 WESTLOCK 2649SBYN00042BEI-0057 10058 10159 10260 10361 10462 105

Line NumberA/essel No. NG-006-24"-E41

ZUEITINA OIL COMPANY

Data Sheets for ESD and Blowdown Valves- 103A Area

DOC. NO. 2010-0111

ServiceG

ENER

AL

Shut Down Valve

REV 0 DATE 30/06/2010

Filter Seperator C-20 Inlet ESD Valve

Area Classification CLASS 1, ZONE 1, GAS GROUP HA, T3Start-Up Bypass Valve 62-XV-6022 (Refer Sheet 11)

Tag Number 62-XV-6020PID Number 40227/PR/1/02/102

Function

SER

VIC

E C

ON

DIT

ION

S

Fluid Natural GasPhase Gas

Maximum MinimumFlow Rate

Max. Shutoff Differential Pressure 485

0Inlet Pressure 485 420

300

Inlet Temperature 101 95

Fluid Density 25.2Fluid Viscosity @ OP. TEMP 0.01

Design Pressure 1360Design Temperature 200

Critical Press Pc -

Size

Spring Return, air piston operated.

Valvitalia LPS-16-530-CM29

Carbon Steel

Actuating Medium Inst. Air Double block & bleed Required

LIN

E Line Size & thicknessIn 24" / 15.88 mm WT TypeOut 24" /15.88 mm WT Spring Material

Mfr & Model

Air Failure position Fail Close24" ASME Class 600 lb Valve Breakaway Torque 5626 Nm

485 psi

2478 / 3221 NmMfr & Model 55 Actuator Break/Run Torque 13550 /4706 NmMax. Press/Temp 1360 Psi / 200°F Valve Run/Seating Torque

Yes

Liner Material/ID N/A Process Connection Top/Side Mounting24", RF, 600 lb On/Off Yes

End

Fig Face Finish RF, Smooth Finish.ASME B16.5 Mechanical Limit Stop

Body/Bonnet Matl

24", RF, 600 lb Speed Control

ASTM A350 LF2 Maximum Shutoff DP

1 Sec for Nominal inch

Required (Mechanical)Type of Bonnet Standard Enclosure Material

Local Control Cabinet Stainless Steel

AC

TUA

TOR

Pipe Line Insulation

CSLub & I so Valve Yes

Yes

Not RequiredFlow DirectionVA

LVE

BO

DY/

BO

NN

ET

Type Ball Valve (Reduced Bore)

Body/Bonnet Gasket Spiral Wound SS316L with Graphite FillerBolts / Nuts ASTM A193 Gr B7M / A194 Gr 2HM

Packing Material PTFE or Equivalent

Bi-directional valve

Local Position Indicator

End Ext/Matl Not Applicable HandwheelMax. stroke Time

TRIM

Type Ball Filter Reg & Gauge

Balanced/Unbalanced N/A Regulator Pressure Range

Ball ASTM A350 LF2 + ENP 0,001"

Characteristic On-Off Valve Supply PressureSize RB Line Filter Required

Tag Number 62-SOV-6020A and 62-SOV-6020B

REGU

LATO

R

Instrument Air

RequiredProcess Connection 1/2" NPT (F)Mfr & Model Maxseal IFR4 1/2" NPT

59,5 psi g (4,1 barg)Rated N/A Relief Valve Set Pressure 87 psi g (6 barg)

ASCO NFET8327B2023/2 Way/316 SSValve OPEN

Stem/TrunnionSeat Ring Material ASTM A350 LF2 + ENP 0,001" Solenoid Energised

Mfr. & Model17-4-PH + ENP 0,001" Type & Material

24VDC± 10%Other seal VITON AED+GRAPHITE Enclosure Class / Material EEx'd'/316 SSSeals VITON AED Voltage Rating

SOLE

NO

ID V

ALV

E

Conduit Connection SizeAir Accumulator N/A Manual Reset- Capacity N/A

Partial Stroking Facility Required, Local Contacts RatingValve Control Panel

N/A Type

Mfr & Model

Proximity Type, Hermetical Seal, DPDT- Pressure Switch N/A Quantity- Relief Valve

IP 67

TEST

S

Hydrostatic / Pneumatic

Fire Test API 6FA

Required, SS 316, IP 65

Local Reset Yes

24V DC @ 1AHydraulic Power Pack Not Required Enclosure Class / Material

SPEC

IALS

/ A

CC

ESSO

RIE

S

LIM

IT S

WIT

CH

API 598/API 6DANSI/FCI Leakage Class High Tightness Class VI

Page 9: Cover pneumatic valves.pdf · 2013. 9. 10. · API 598/API 6D API 6FA ANSI/FCI Leakage Class High Tightness Class VI Fire Test Local Reset Yes TESTS Hydrostatic / Pneumatic ... Area

123456789

10 Units Normal Shut-Off11 mmscfd 248.3-300 -

12 psig 42013 °F 10014 psi -

15 psig16 °F -

17 Kg/m3 -

18 CP -

19 psi20 6321 6422 6523 6624 6725 6826 6927 7028 7129 7230 In 7331 Out 7432 7533 7634 7735 7836 7937 8038 8139 8240 8341 8442 8543 8644 8745 8846 8947 9048 9149 9250 9351 94 M20 x 1,552 95 N.A.53 9654 9755 98 4 Nos.56 99 WESTLOCK 2649SBYN00042BEI-0057 10058 10159 10260 10361 10462 105

ZUEITINA OIL COMPANY

Data Sheets for ESD and Blowdown Valves- 103A Area

DOC. NO. 2010-0111 REV 0 DATE 30/06/2010

GEN

ERA

LTag Number 62-XV-6100PID Number 40227/PR/1/02/108Service Compressor K-10 InletLine NumberA/essel No. NG-101-24"-E41Function Unit Shut Down ValveArea Classification CLASS 1, ZONE 1, GAS GROUP IIA, T3Start-Up Bypass Valve 62-XV-6101 (Refer Sheet 13)Fluid Natural Gas

Maximum MinimumPhase Gas

525

0Inlet Pressure 475 415Flow Rate

Inlet Temperature 101 92

300

SER

VIC

E C

ON

DIT

ION

S

Fluid Density 25.2Fluid Viscosity @ OP. TEMP 0.01

Design Pressure 1360Design Temperature 200

Max. Shutoff Differential Pressure

Required Air Failure position

Critical Press Pc -

Spring Return, air piston operated.Carbon SteelValvitalia LPS-16-530-CM29

Inst. AirDouble block & bleed

Spring Material

LIN

E Line Size & thicknessIn 24" /15.88 mm WT TypeOut 24" /15.88 mm WT

Mfr & Model

Body/Bonnet Matl ASTM A350 LF2 Maximum Shutoff DP 525 psi

Fail Close

VALV

E B

OD

Y/BO

NN

ET

Type Ball Valve (Reduced Bore) Actuating Medium

SizeMax. Press/Temp 1360 Psi / 200 °F Valve Run/Seating Torque 2478 / 3221 Nm

Speed Control Yes

YesEnd

5627 Nm24" ASME Class 600 lb Valve Breakaway Torque

55 Actuator Break/Run Torque 13550 /4706 Nm

CS

Fig Face Finish RF, Smooth Finish.ASME B16.5 Mechanical Limit Stop

1 Sec for Nominal inchNot RequiredYes

Liner Material/ID N/A Process Connection Top/Side Mounting24", RF, 600 lb

Spiral Wound SS316L with Graphite Filler

Lub & Iso Valve

Max. stroke TimeEnd Ext/Matl Not Applicable Handwheel

Local Position Indicator

On/Off24", RF, 600 lb

Required (Mechanical)Type of Bonnet Standard Enclosure Material

AC

TUA

TOR

Pipe Line Insulation

Yes

Flow Direction Bi-directional valve

Mfr & Model

Required

Packing Material PTFE or Equivalent Local Control Cabinet Stainless SteelMaxseal IFR4 1/2" NPT

Bolts / Nuts ASTM A193 Gr B7M / A194 Gr 2HM Process Connection 1/2" NPT (F)

trim

Type Ball Filter Reg & Gauge

Characteristic On-Off Valve Supply Pressure

Seat Ring Material ASTM A350 LF2 + ENP 0,001" Solenoid Energised

RatedN/A Regulator Pressure RangeN/A

REGU

LATO

R

Size RB

Body/Bonnet Gasket

Balanced/Unbalanced

Mfr & Model

59,5 psi g (4,1 barg)

RequiredInstrument Air

Relief Valve Set Pressure 87 psi g (6 barg)

Line Filter

Ball ASTM A350 LF2 + ENP 0,001" Tag Number 62-SOV-6100A and 62-SOV-6100B

Valve OPENSeals VITON AED Voltage Rating 24VDC ± 10%

ASCO NFET8327B202Stem/Trunnion 17-4-PH + ENP 0,001" Type & Material 3/2 Way/316 SS

Mfr. & Model

SOLE

NO

ID V

ALV

E

EEx'd'/316 SSConduit Connection SizeEnclosure Class / Material

- Relief Valve Type Proximity Type, Hermetical Seal, DPDT- Capacity N/A

24V DC @ 1AHydraulic Power Pack Not Required Enclosure Class / Material IP 67

Required, Local Contacts RatingPartial Stroking Facility

Other seal

Manual Reset

Mfr & Model- Pressure Switch N/A Quantity

N/A

LIM

IT S

WIT

CH

VITON AED+GRAPHITE

API 598/API 6DHydrostatic / Pneumatic

TEST

S ANSI/FCI Leakage Class

Valve Control Panel Required, SS 316, IP 65SPEC

IALS

/ A

CC

ESSO

RIE

S

Air Accumulator N/A

Local Reset Yes

High Tightness Class VIFire Test API 6FA

Page 10: Cover pneumatic valves.pdf · 2013. 9. 10. · API 598/API 6D API 6FA ANSI/FCI Leakage Class High Tightness Class VI Fire Test Local Reset Yes TESTS Hydrostatic / Pneumatic ... Area

123456789

10 Units Normal Shut-Off11 mmscfd 248.3-300 -

12 psig 42013 °F 100 -

14 psi -

15 psig16 °F -

17 Kg/m3 -

18 CP -

19 psi20 6321 6422 6523 6624 6725 6826 6927 7028 7129 7230 In 7331 Out 7432 7533 7634 7735 7836 7937 8038 8139 8240 8341 8442 8543 8644 8745 8846 8947 9048 9149 9250 9351 94 M20 x 1,552 95 N.A.53 9654 9755 98 4 Nos.56 99 WESTLOCK 2649SBYN00042BEI-0057 10058 10159 10260 10361 10462 105

Line NumberA/essel No. NG-102-24"-E41

ZUEITINA OIL COMPANY

Data Sheets for ESD and Blowdown Valves- 103A Area

DOC. NO. 2010-0111

ServiceG

ENER

AL

Unit Shut Down Valve

REV 0 DATE 30/06/2010

Compressor K-20 Inlet

Area Classification CLASS 1, ZONE 1, GAS GROUP IIA, T3Start-Up Bypass Valve 62-XV-6201 (Refer Sheet 17)

Tag Number 62-XV-6200PID Number 40227/PR/1/02/109

Function

SER

VIC

E C

ON

DIT

ION

S

Fluid Natural GasPhase Gas

Maximum MinimumFlow Rate

Max. Shutoff Differential Pressure 525

0Inlet Pressure 475 415

300

Inlet Temperature 101 92

Fluid Density 25.2Fluid Viscosity @ OP. TEMP 0.01

Design Pressure 1360Design Temperature 200

LIN

E Line Size & thicknessIn 24" /15.88 mm WT TypeOut 24" / 15.88 mm WT Spring Material Carbon Steel

Mfr & Model Valvitalia LPS-16-530-CM29

Critical Press Pc -

Spring Return, air piston operated.

Pipe Line Insulation

VALV

E B

OD

Y/B

ON

NET

Type Ball Valve (Reduced Bore) Actuating Medium

Size 24" ASME Class 600 lb Valve Breakaway Torque

Mfr & Model 55 Actuator Break/Run Torque

Double block & bleed Required Air Failure position Fail Close

ASTM A350 LF2 Maximum Shutoff DP 525 psi

5627 Nm

13550 /4706 NmMax. Press/Temp 1360 Psi / 200 °F Valve Run/Seating Torque 2478 / 3221 Nm

Yes

Top/Side Mounting24", RF, 600 lb On/Off Yes

Process Connection

CSFlow Direction

End

Body/Bonnet MatlLiner Material/ID N/A

24", RF, 600 lbFig Face Finish RF, Smooth Finish.ASME B16.5 Mechanical Limit Stop

Not Required1 Sec for Nominal inch

End Ext/Matl Not Applicable HandwheelBi-directional valve Max. stroke Time

Stainless SteelPTFE or Equivalent Local Control Cabinet

AC

TUA

TOR

Yes Local Position Indicator Required (Mechanical)

YesSpeed Control

Inst. Air

Enclosure Material

Body/Bonnet Gasket Spiral Wound SS316L with Graphite Filler

ASTM A350 LF2 + ENP 0,001"

Balanced/UnbalancedN/A

Lub & I so Valve

Size

REGU

LATO

R

Packing Material

Type of Bonnet Standard

Mfr & Model Maxseal IFR4 1/2" NPTBolts / Nuts ASTM A193 Gr B7M / A194 Gr 2HM Process Connection 1/2" NPT (F)

Filter Reg & Gauge Required

Relief Valve Set Pressure

trim

Type Ball

Characteristic On-Off Valve

Rated 87 psi g (6 barg)

Supply Pressure Instrument Air

Tag Number

RB Line Filter Required

N/A Regulator Pressure Range 59,5 psi g (4,1 barg)

62-SOV-6200A and 62-SOV-6200BASCO NFET8327B2023/2 Way/316 SSStem/Trunnion 17-4-PH + ENP 0,001" Type & Material

Ball

Manual Reset

Valve OPEN

Conduit Connection Size

VITON AED Voltage Rating 24VDC±10%VITON AED+GRAPHITE Enclosure Class / Material EEx'd'/316 SS

Mfr & Model

Proximity Type, Hermetical Seal, DPDT

N/AN/A

SOLE

NO

ID V

ALV

E Mfr. & Model

N/A Type- Pressure Switch N/A Quantity

Seat Ring Material ASTM A350 LF2 + ENP 0,001" Solenoid Energised

Other seal Seals

- Capacity- Relief Valve

24VDC@1AHydraulic Power Pack Not Required Enclosure Class / Material IP 67Partial Stroking Facility Required, Local Contacts Rating

API 598/API 6DYes

Fire Test API 6FA

Local ResetHydrostatic / Pneumatic

SPEC

IALS

/ A

CC

ESSO

RIE

S

LIM

IT S

WIT

CH

TEST

S

Valve Control Panel Required, SS 316, IP 65

Air Accumulator

ANSI/FCI Leakage Class High Tightness Class VI

Page 11: Cover pneumatic valves.pdf · 2013. 9. 10. · API 598/API 6D API 6FA ANSI/FCI Leakage Class High Tightness Class VI Fire Test Local Reset Yes TESTS Hydrostatic / Pneumatic ... Area

123456789

10 Units Normal Shut-Off11 mmscfd 248.3-1500 -

12 psig 778-132313 °F 126 -

14 psi -

15 psig16 °F -

17 Kg/m3 -

18 CP -

19 psi20 6321 6422 6523 6624 6725 6826 6927 7028 7129 7230 In 7331 Out 7432 7533 7634 7735 7836 7937 8038 8139 8240 8341 8442 8543 8644 8745 8846 8947 9048 9149 9250 9351 94 M20 x 1,552 95 N.A.53 9654 9755 98 4 Nos.56 99 WESTLOCK 2649SBYN00042BEI-0057 10058 10159 10260 10361 10462 105

Line NumberA/essel No. NG-016-36"-F40

ZUEITINA OIL COMPANY

Data Sheets for ESD and Blowdown Valves- 103A Area

DOC. NO. 2010-0111

ServiceG

ENER

AL

Shut Down Valve

REV 0 DATE 30/06/2010

Pig Launcher-103A

Area Classification CLASS 1, ZONE 1, GAS GROUP HA, T3Start-Up Bypass Valve 62-XV-6086 (Refer Sheet 23)

Tag Number 62-XV-6085PID Number 40227/PR/1/02/116

Function

SER

VIC

E C

ON

DIT

ION

S

Fluid Natural GasPhase Gas

Maximum MinimumFlow Rate

Max. Shutoff Differential Pressure 1338

248.3Inlet Pressure 1338 775

1500

Inlet Temperature 130 125

Fluid Density 44-78.3Fluid Viscosity @ OP. TEMP 0.01 to 0.02

Design Pressure 1480Design Temperature 300

LIN

E Line Size & thicknessIn 36" / 23.83 mm W.T TypeOut 36" / 23.83 mm W.T Spring Material

Size

Carbon SteelMfr & Model Valvitalia LPS-20-940-CM34

36" ASME Class 900 lb

Critical Press Pc -

Spring Return, air piston operated.

Valve Breakaway Torque 26632 Nm

Inst. Air Double block & bleed Required Air Failure position Fail Close

VALV

E B

OD

Y/B

ON

NET

Type Ball Valve (Reduced Bore) Actuating Medium

Max. Press/Temp 1480 Psi / 200°F Valve Run/Seating Torque

Maximum Shutoff DP

RF, Smooth Finish.ASME B16.47 Series A Mechanical Limit Stop

8975 / 11668 NmMfr & Model 55 Actuator Break/Run Torque 52265 /20211 Nm

1338 psiLiner Material/ID N/A Process Connection Top/Side MountingBody/Bonnet Matl ASTM A350 LF2

Yes

36", RF, 900 lb On/Off Yes36", RF, 900 lb Speed Control Yes

Not RequiredFlow Direction Bi-directional valve Max. stroke Time 1 Sec for Nominal inch

End

End Ext/Matl Not Applicable HandwheelFig Face Finish

CSLub & I so Valve Yes Local Position Indicator Required (Mechanical)Type of Bonnet Standard Enclosure Material

AC

TUA

TOR

Pipe Line Insulation

Required

Packing Material PTFE or Equivalent Local Control Cabinet Stainless SteelMaxseal IFR4 1/2" NPT

Bolts / Nuts ASTM A193 Gr B7M / A194 Gr 2HM Process Connection 1/2" NPT (F)

TRIM

Type Bail Filter Reg & Gauge

Characteristic On-Off Valve Supply PressureSize RB Line Filter

Body/Bonnet Gasket Spiral Wound SS316L with Graphite Filler Mfr & Model

Instrument AirBalanced/Unbalanced N/A Regulator Pressure Range 59,5 psi g (4,1 barg)

87 psi g (6 barg)Ball ASTM A350 LF2+0,001" ENP Tag Number 62-SOV-6085A and 62-SOV-6085BRated N/A Relief Valve Set Pressure

REGU

LATO

R

Required

ASCO NFET8327B202Stem/Trunnion 17-4-PH + ENP 0,001" Type & Material 3/2 Way/316 SS

Mfr. & Model

Valve OPENSeals VITON AED Voltage Rating 24VDC± 10%

ASTM A350 LF2 + ENP 0,001" Solenoid EnergisedSeat Ring Material

N/A Manual Reset

Other seal VITON AED + GRAPHITE Enclosure Class / Material

- Capacity N/A

SOLE

NO

ID V

ALV

E

Air Accumulator

EEx'd' / 316 SSConduit Connection Size

Proximity Type, Hermetical Seal, DPDT- Pressure Switch N/A Quantity- Relief Valve N/A Type

Valve Control Panel Required, SS 316, IP 65 Mfr & Model

Hydraulic Power PackPartial Stroking Facility Required, Local Contacts Rating 24V DC @ 1A

IP 67Local Reset Yes

Not Required Enclosure Class / Material

TEST

S

Hydrostatic / Pneumatic

Fire Test

SPEC

IALS

/ A

CC

ESSO

RIE

S

LIM

IT S

WIT

CH

API 598/API 6D

API 6FAANSI/FCI Leakage Class High Tightness Class VI

Page 12: Cover pneumatic valves.pdf · 2013. 9. 10. · API 598/API 6D API 6FA ANSI/FCI Leakage Class High Tightness Class VI Fire Test Local Reset Yes TESTS Hydrostatic / Pneumatic ... Area

123456789

10 Units Normal Shut-Off11 mmscfd 248.3 - 300 -

12 psig 74713 °F 55-120 -

14 psi -

15 psig16 °F -

17 Kg/m3 -

18 CP -

19 psi20 6321 6422 6523 6624 6725 6826 6927 7028 7129 7230 In 7331 Out 7432 7533 7634 7735 7836 7937 8038 8139 8240 8341 8442 8543 8644 8745 8846 8947 9048 9149 9250 9351 94 M20 x 1,552 95 N.A.53 9654 9755 98 4 Nos. 56 99 WESTLOCK 2649SBYN00042BEI-00

57 10058 10159 10260 10361 10462 105

API 598/APl 6DANSI/FCI Leakage Class High Tightness Class VI

API 6FA

GEN

ERA

L

Tag Number 63-XV-6010PID Number 40227/PR/2/02/110

Service Filter Seperator C-10 Inlet ValveLine NumberA/essel No. NG-004-18"-E40Function Shut Down ValveArea Classification CLASS 1, ZONE 1, GAS GROUP HA, T3

DATE 30/06/2010DOC. NO. 2010-0111 REV 0

Start-Up Bypass Valve 63-XV-6011 (Refer Sheet 7)

SER

VIC

E C

ON

DIT

ION

S

Fluid Natural GasPhase Gas

Maximum Minimum

Inlet Temperature 125 50Max. Shutoff Differential Pressure 1292

Flow Rate 300 248.3Inlet Pressure 1292 740

Fluid Density 46.8

Fluid Viscosity @ OP. TEMP 0.01 to 0.02

Design Pressure 1360Design Temperature 200

LIN

E Line Size & thicknessIn 18"/SCHSTD TypeOut 18"/SCHSTD Spring Material

Critical Press Pc -

Spring Return, air piston operated.Carbon SteelValvitalia LPS-13-530-CM25Mfr & Model

Size 18" ASME Class 600 lb Valve Breakaway Torque 4655 Nm

Type Ball Valve (Reduced Bore) Actuating Medium

1292 psi

Max. Press/Temp 1360 Psi / 200°F Valve Run/Seating Torque 1427 / 1856 Nm11688 /3114 Nm

VALV

E B

OD

Y/B

ON

NET

Inst. Air Double block & bleed Required Air Failure position Fail Close

Body/Bonnet Matl ASTM A350 LF2 Maximum Shutoff DP

End Conn.18", RF, 600 lb On/Off

Mfr & Model 55 Actuator Break/Run Torque

Liner Material/ID N/A Process Connection Top/Side Mounting

Mechanical Limit Stop Yes

18", RF, 600 lb Speed Control Yes

Yes

Flow Direction Bi-directional valve Max. stroke TimeEnd Ext/Matl Not Applicable Handwheel NoFig Face Finish RF, Smooth Finish.ASME B16.5

Type of Bonnet Standard Enclosure Material CS Lub & I so Valve Yes Local Position Indicator Yes (Mechanical)

Body/Bonnet Gasket Spiral Wound SS316L with Graphite Filler

REGU

LATO

R

Mfr & ModelBolts / Nuts ASTM A193 Gr B7M / A194 Gr 2HM Process ConnectionType Ball Filter Reg & Gauge

Maxseal IFR4 1/2" NPT1/2" NPT(F)

TRIM

YesSize RB Line Filter YesCharacteristic On-Off Valve

Rated N/A Relief Valve Set Pressure 87 psi g (6 barg)

Supply Pressure Instrument AirBalanced/Unbalanced N/A Regulator Pressure Range 59,5 psi g (4,1 barg)

Ball ASTM A350 LF2 + ENP 0,001" Tag NumberMfr. & Model

3/2 Way/316 SS

Seals VITON AED Voltage Rating 24VDC+ 10%Seat Ring Material ASTM A350 LF2 + ENP 0,001" Solenoid EnergisedStem/Trunnion

Other seal VITON AED + GRAPHITE Enclosure Class / Material EEx'd'/316 SS

SOLE

NO

ID V

ALV

E

Valve OPEN

63-SOV-6010A and 63-SOV-6010B

ASCO NFET8327B20217-4-PH + ENP 0,001" Type & Material

SPEC

IALS

/A

CC

ESSO

RIE

S

Conduit Connection SizeAir Accumulator N/A Manual Reset- Capacity N/A

Valve Control Panel

Proximity Type, Hermetical Seal, DPDT- Relief Valve N/A Type- Pressure Switch N/A Quantity

Yes

Partial Stroking Facility Required, Local Contacts Rating

LIM

IT S

WIT

CH

24V DC @ 1AHydraulic Power Pack Not Required Enclosure Class / Material IP 67

Required, SS 316, IP 65 Mfr & Model

Local ResetHydrostatic / Pneumatic

TEST

S

Fire Test

ZUEITINA OIL COMPANY

Data Sheets for ESD and Blowdown Valves- PRMS Area

Pipe Line Insulation

AC

TUA

TOR

Packing Material PTFE or Equivalent Local Control Cabinet Stainless Steel

1 Sec for Nominal inch

Page 13: Cover pneumatic valves.pdf · 2013. 9. 10. · API 598/API 6D API 6FA ANSI/FCI Leakage Class High Tightness Class VI Fire Test Local Reset Yes TESTS Hydrostatic / Pneumatic ... Area

123456789

10 Units Normal Shut-Off11 mmscfd 248.3 - 300 -

12 psig 74713 °F 55-120 -

14 psi -

15 psig16 °F -

17 Kg/m3 -

18 CP -

19 psi20 6321 6422 6523 6624 6725 6826 6927 7028 7129 7230 In 7331 Out 7432 7533 7634 7735 7836 7937 8038 8139 8240 8341 8442 8543 8644 8745 8846 8947 9048 9149 9250 9351 94 M20 x 1,552 95 N.A.53 9654 9755 98 4 Nos. 56 99 WESTLOCK 2649SBYN00042BEI-00

57 10058 10159 10260 10361 10462 105 API 6FAFire Test

Hydrostatic / Pneumatic

TEST

S

REV

Area Classification CLASS 1, ZONE 1, GAS GROUP HA, T3Start-Up Bypass Valve 63-XV-6021 (Refer Sheet 9)

GEN

ERA

L

Tag Number

ANSI/FCI Leakage Class High Tightness Class VI

ServiceLine NumberA/essel No. NG-005-18"-E40Function Shut Down Valve

API 598/API 6D

ZUEITINA OIL COMPANY

Data Sheets for ESD and Blowdown Valves- PRMS Area

DOC. NO. 2010-0111 0 DATE 30/06/2010

63-XV-6020PID Number 40227/PR/2/02/111

Filter Seperator C-20 Inlet Valve

SER

VIC

E C

ON

DIT

ION

S

Fluid Natural GasPhase Gas

Maximum MinimumFlow Rate 300

Inlet Temperature 125 50Max. Shutoff Differential Pressure 1292

248.3Inlet Pressure 1292 740

Fluid Density 46.8Fluid Viscosity @ OP. TEMP 0.01 to 0.02

Design Pressure 1360Design Temperature 200

LIN

E Line Size & thicknessIn 18"/SCHSTD TypeOut 18"/SCHSTD Spring Material

Valve Breakaway Torque

Carbon SteelMfr & Model Valvitalia LPS-13-530-CM25

Critical Press Pc -

Spring Return, air piston operated.

Valve Run/Seating Torque 1427 / 1856 Nm

Inst. AirFail Close4655 Nm

Pipe Line Insulation

18" ASME Class 600 lb

VALV

E B

OD

Y/B

ON

NET

Type Ball Valve (Reduced Bore) Actuating MediumDouble block & bleed Required Air Failure positionSizeMax. Press/Temp 1360 Psi / 200°F

1292 psiMfr & Model 55 Actuator Break/Run Torque 11688 /3114 Nm

Maximum Shutoff DPN/A

Fig Face Finish RF, Smooth Finish.ASME B16.5

Body/Bonnet Matl ASTM A350 LF2

End Ext/Matl Not Applicable Handwheel

Process Connection

End Conn.18", RF, 600 lb On/Off18", RF, 600 lb Speed Control

Liner Material/ID Top/Side MountingYesYes

NoYes

Maxseal IFR4 1/2" NPT

Yes (Mechanical)

Max. stroke Time 1 Sec for Nominal inch

Local Position IndicatorPacking Material PTFE or Equivalent Local Control Cabinet Stainless Steel

AC

TUA

TOR

Type of Bonnet Standard Enclosure Material CS

Mechanical Limit Stop

Flow Direction Bi-directional valve

Lub & I so Valve Yes

Body/Bonnet Gasket Spiral Wound SS316L with Graphite Filler Mfr & ModelBolts / Nuts 1/2 " NPT (F)

Size RB Line Filter

Rated N/A 87 psi g (6 barg)

ASTM A193 Gr B7M / A194 Gr 2HM Process ConnectionType Ball Filter Reg & Gauge

Balanced/Unbalanced N/A

17-4-PH + ENP 0,001" Type & Material

TRIM

YesYes

Characteristic On-Off Valve Supply Pressure Instrument Air59,5 psi g (4,1 barg)Regulator Pressure Range

Tag NumberRelief Valve Set Pressure

Seals VITON AED Voltage RatingSolenoid Energised

REGU

LATO

R

ASTM A350 LF2 + ENP 0,001"

Stem/Trunnion

24VDC ± 10%

63-SOV-6020A and 63-SOV-6020BASCO NFET8327B202Mfr. & Model

Ball

3/2 Way/316 SSSeat Ring Material ASTM A350 LF2 + ENP 0,001"

Other seal VITON AED + GRAPHITE Enclosure Class / Material EEx'd'/316 SS

Valve OPEN

SOLE

NO

ID V

ALV

E

SPEC

IALS

/A

CC

ESSO

RIE

S

Conduit Connection SizeAir Accumulator N/A Manual Reset- Capacity N/A- Relief Valve N/A

LIM

IT S

WIT

CH

Type Proximity Type, Hermetical Seal, DPDT- Pressure Switch N/A

24V DC @ 1AHydraulic Power Pack Not Required Enclosure Class / Material IP 67Local Reset Yes

Partial Stroking Facility Required, Local

QuantityValve Control Panel Required, SS 316, IP 65 Mfr & Model

Contacts Rating

Page 14: Cover pneumatic valves.pdf · 2013. 9. 10. · API 598/API 6D API 6FA ANSI/FCI Leakage Class High Tightness Class VI Fire Test Local Reset Yes TESTS Hydrostatic / Pneumatic ... Area

123456789

10 Units Normal Shut-Off11 mmscfd 0-250 -

12 psig 72813 °F 95 -

14 psi -

15 psig16 °F -

17 Kg/m3 -

18 CP -

19 psi20 6321 6422 6523 6624 6725 6826 6927 7028 7129 7230 In 7331 Out 7432 7533 7634 7735 7836 7937 8038 8139 8240 8341 8442 8543 8644 8745 8846 8947 9048 9149 9250 9351 94 M20 x 1,552 95 N.A.53 9654 9755 98 4 Nos.56 99 WESTLOCK 2649SBYN00042BEI-00

57 10058 10159 10260 10361 10462 105

ANSI/FCI Leakage Class High Tightness Class VIFire Test API 6FA

Hydrostatic / Pneumatic API 598/API 6D

GEN

ERA

L

Tag Number 63-XV-6225PID Number 40227/PR/2/02/140Service

Function Shut Down ValveArea Classification CLASS 1, ZONE 1, GAS GROUP IIA, T3

Start-Up Bypass Valve 63-XV-6226 (Refer Sheet 15)

Benghazi BranchLine NumberA/essel No. NG-036-18"-E40

DOC. NO. 2010-0111 REV 0 DATE 30/06/2010

ZUEITINA OIL COMPANY

Data Sheets for ESD and Blowdown Valves- PRMS Area

SER

VIC

E C

ON

DIT

ION

S

Fluid Natural GasPhase Gas

Maximum MinimumFlow Rate 250

Inlet Temperature 125 90Max. Shutoff Differential Pressure 1292

0Inlet Pressure 1292 720

Fluid Density 31Fluid Viscosity @ OP. TEMP 0.01 to 0.02

Design Pressure 1360Design Temperature 200

LIN

E Line Size & thicknessIn 18"/SCHSTD TypeOut 18"/SCHSTD Spring Material

Mfr & Model Valvitalia LPS-13-530-CM25

Critical Press Pc -

Spring Return, air piston operated.Carbon Steel

Pipe Line Insulation

VALV

E B

OD

Y/B

ON

NET

Type Ball Valve (Reduced Bore) Actuating MediumDouble block & bleed Required Air Failure positionSize 18" ASME Class 600 lb Valve Breakaway Torque

Liner Material/ID N/A Process Connection

Inst. Air Fail Close4655 Nm

Max. Press/Temp 1360 Psi / 200°F Valve Run/Seating Torque 1427 / 1856 NmMfr & Model 55 Actuator Break/Run TorqueBody/Bonnet Matl ASTM A350 LF2 Maximum Shutoff DP

11688 /3114 Nm1292 psiTop/Side Mounting

End Conn.18", RF, 600 lb On/Off Yes18", RF, 600 lb Speed Control Yes

End Ext/Matl Not Applicable Handwheel NoFig Face Finish RF, Smooth Finish.ASME B16.5 Mechanical Limit Stop Yes

Yes Local Position Indicator Yes (Mechanical)

Flow Direction Bi-directional valve Max. stroke Time 1 Sec for Nominal inch

Stainless SteelPacking Material PTFE or Equivalent Local Control Cabinet

AC

TUA

TOR

Type of Bonnet Standard Enclosure Material CSLub & Iso Valve

RB

Body/Bonnet Gasket Spiral Wound SS316L with Graphite Filler Mfr & Model

Type BallBolts / Nuts ASTM A193 Gr B7M / A194 Gr 2HM

Maxseal IFR4 1/2" NPT

REGU

LATO

R

1/2" NPT (F)Process ConnectionYes

59,5 psi g (4,1 barg)

Filter Reg & GaugeYes

87 psi g (6 barg)

Instrument Air

TRIM

Characteristic On-Off Valve Supply Pressure

Rated N/A

Size

Regulator Pressure Range

Line Filter

N/A

Seat Ring Material ASTM A350 LF2 + ENP 0,001" Solenoid Energised17-4-PH + ENP 0,001" Type & Material

Relief Valve Set PressureBalanced/Unbalanced

Valve OPEN

Ball ASTM A350 LF2 + ENP 0,001" Tag NumberMfr. & Model

Stem/Trunnion

63-SOV-6225A and 63-SOV-6225BASCO NFET8327B2023/2 Way/316 SS

EEx'd'/316 SS

Seals VITON AED Voltage Rating 24VDC ± 10%Other seal VITON AED + GRAPHITE Enclosure Class / Material

Conduit Connection Size

- Relief Valve

Valve Control Panel Required, SS 316, IP 65

N/AN/A Quantity

SOLE

NO

ID V

ALV

E

Manual Reset

SPEC

IALS

/A

CC

ESSO

RIE

S

Air Accumulator N/A- Capacity N/A

Not RequiredPartial Stroking Facility Required, Local 24V DC @ 1A

Type Proximity Type, Hermetical Seal, DPDT

Enclosure Class / Material IP 67

Mfr & ModelContacts Rating

LIM

IT S

WIT

CH

TEST

S

Local Reset Yes

- Pressure Switch

Hydraulic Power Pack

Page 15: Cover pneumatic valves.pdf · 2013. 9. 10. · API 598/API 6D API 6FA ANSI/FCI Leakage Class High Tightness Class VI Fire Test Local Reset Yes TESTS Hydrostatic / Pneumatic ... Area

123456789

10 Units Normal Shut-Off11 mmscfd 0-250 -

12 psig 50013 °F 40-80 -

14 psi -

15 psig16 °F -

17 Kg/m3 -

18 CP -

19 psi20 6321 6422 6523 6624 6725 6826 6927 7028 7129 7230 In 7331 Out 7432 7533 7634 7735 7836 7937 8038 8139 8240 8341 8442 8543 8644 8745 8846 8947 9048 9149 9250 9351 94 M20 x 1,552 95 N.A.53 9654 9755 98 4 Nos.56 99 WESTLOCK 2649SBYN00042BEI-00

57 10058 10159 10260 10361 10462 105TE

STS

Hydrostatic / Pneumatic API 598/API 6D

Fire Test API 6FAANSI/FCI Leakage Class High Tightness Class VI

Service Benghazi BranchLine NumberA/essel No.Function Shut Down ValveArea Classification CLASS 1, ZONE 1, GAS GROUP IIA, T3

ZUEITINA OIL COMPANY

Data Sheets for ESD and Blowdown Valves- PRMS Area

DOC. NO. 2010-0111 REV 0 DATE 30/06/2010

Start-Up Bypass Valve 63-XV-6605 (Refer Sheet 19)

GEN

ERA

L

Tag Number 63-XV-6604PID Number 40227/PR/2/02/150

NG-039-20"-E40SE

RVI

CE

CO

ND

ITIO

NS

Fluid Natural GasPhase Gas

Maximum MinimumFlow Rate 250

Inlet Temperature 100 35Max. Shutoff Differential Pressure 847

0Inlet Pressure 770 500

Fluid Density 31Fluid Viscosity @ OP. TEMP 0.01 to 0.02

Design Pressure 1360Design Temperature 200

Critical Press Pc -

Spring Return, air piston operated.

Pipe Line Insulation

LIN

E Line Size & thicknessIn 20" / SCH STD TypeOut 20" / SCH STD Spring Material

847 psi

Required Air Failure positionSize 20" ASME Class 600 lb

HandwheelFig Face Finish

Carbon SteelMfr & Model Valvitalia LPS-13-530-CM25

1792 / 2329 Nm

Inst. AirFail Close

Valve Breakaway Torque 4248 Nm

Body/Bonnet Matl ASTM A350 LF2 Maximum Shutoff DP

VALV

E B

OD

Y/B

ON

NET

Type Ball Valve (Reduced Bore) Actuating MediumDouble block & bleed

Speed Control

Mfr & ModelMax. Press/Temp 1360 Psi / 200 °F Valve Run/Seating Torque

11688 /3114 Nm55 Actuator Break/Run Torque

20", RF, 600 lb On/Off20", RF, 600 lb

N/A Process Connection

Packing Material PTFE or Equivalent

AC

TUA

TOR

Local Control Cabinet

Type of Bonnet Standard Enclosure Material

Liner Material/ID

End Ext/Matl Not ApplicableFlow Direction Bi-directional valve Max. stroke Time

Top/Side MountingYesYes

RF, Smooth Finish.ASME B16.5 Mechanical Limit Stop Yes

End Conn.

Bolts / Nuts ASTM A193 Gr B7M / A194 Gr 2HM Process Connection

No1 Sec for Nominal inchCS

Lub & Iso Valve Yes Local Position Indicator Yes (Mechanical)

Body/Bonnet Gasket Spiral Wound SS316L with Graphite Filler Mfr & Model Maxseal IFR4 1/2" NPT

On-Off ValveRegulator Pressure Range 59,5 psi g (4,1 barg)

87 psi g (6 barg)

Instrument Air

Stainless Steel

TRIM

Type Ball Filter Reg & GaugeSize RB Line FilterCharacteristic

Ball ASTM A350 LF2 + ENP 0,001" Tag Number

Balanced/UnbalancedRated N/A Relief Valve Set Pressure

N/A

ASCO NFET8327B2023/2 Way/316 SS

1/2" NPT (F)

REGU

LATO

R

Type & Material

63-SOV-6604A and 63-SOV-6604B

YesYes

Supply Pressure

Seat Ring Material ASTM A350 LF2 + ENP 0,001" Solenoid Energised Valve OPEN

Mfr. & ModelStem/Trunnion 17-4-PH + ENP 0,001"

24VDC ± 10%Other seal VITON AED + GRAPHITE Enclosure Class / Material EEx'd'/316 SSSeals VITON AED Voltage Rating

SOLE

NO

ID V

ALV

E

- Capacity

SPEC

IALS

/A

CC

ESSO

RIE

S

Conduit Connection SizeAir Accumulator N/A Manual Reset

Type- Pressure Switch

Local Reset

Proximity Type, Hermetical Seal, DPDTN/A

Required, SS 316, IP 65N/A Quantity

Mfr & ModelContacts Rating 24V DC @ 1AEnclosure Class / Material IP 67

- Relief Valve N/A

LIM

IT S

WIT

CH

Hydraulic Power Pack Not Required

Valve Control PanelPartial Stroking Facility Required, Local

Yes

Page 16: Cover pneumatic valves.pdf · 2013. 9. 10. · API 598/API 6D API 6FA ANSI/FCI Leakage Class High Tightness Class VI Fire Test Local Reset Yes TESTS Hydrostatic / Pneumatic ... Area

123456789

10 Units Normal Shut-Off11 mmscfd 250-1250 -

12 psig 50013 °F 40-80 -

14 psi -

15 psig16 °F -

17 Kg/m3 -

18 CP -

19 psi20 6321 6422 6523 6624 6725 6826 6927 7028 7129 7230 In 7331 Out 7432 7533 7634 7735 7836 7937 8038 8139 8240 8341 8442 8543 8644 8745 8846 8947 9048 9149 9250 9351 94 M20 x 1,552 95 N.A.53 9654 9755 98 4 Nos. 56 99 WESTLOCK 2649SBYN00042BEI-00

57 10058 10159 10260 10361 10462 105

Line NumberA/essel No. NG-031-36"-E40

ZUEITINA OIL COMPANY

Data Sheets for ESD and Blowdown Valves- PRMS Area

DOC. NO. 2010-0111

Service

GEN

ERA

LShut Down Valve

REV 0 DATE 30/06/2010

Tripoli Branch

Area Classification CLASS 1, ZONE 1, GAS GROUP IIA, T3Start-Up Bypass Valve 63-XV-6603 (Refer Sheet 17)

Tag Number 63-XV-6602PID Number 40227/PR/2/02/150

FunctionSE

RVI

CE

CO

ND

ITIO

NS

Fluid Natural GasPhase Gas

Maximum MinimumFlow Rate

Max. Shutoff Differential Pressure 847

0Inlet Pressure 770 500

1250

Inlet Temperature 100 35

Fluid Density 31Fluid Viscosity @ OP. TEMP 0.01 to 0.02

Design Pressure 1360Design Temperature 200

Critical Press Pc -

Spring Return, air piston operated.

Pipe Line InsulationCarbon SteelValvitalia LPS-20-840-CM33

Valve Breakaway Torque

LIN

E Line Size & thicknessIn 36" / 23.83 mm W.T TypeOut 36" / 23.83 mm W.T Spring Material

Mfr & ModelInst. Air Fail Close19595 Nm

Max. Press/Temp 1360 Psi / 200°F Valve Run/Seating Torque 8975 / 11668 Nm

Air Failure positionSize 36" ASME Class 600 lb

VALV

E B

OD

Y/B

ON

NET

Type Ball Valve (Reduced Bore) Actuating MediumDouble block & bleed Required

Actuator Break/Run Torque

Liner Material/ID N/A

RF, Smooth Finish.ASME B16.47 Series A

42577 /15691 NmBody/Bonnet Matl ASTM A350 LF2 Maximum Shutoff DP 847 psiMfr & Model 55

36", RF, 600 lbFig Face Finish

End Conn.36", RF, 600 lb

Mechanical Limit Stop Yes

No

Top/Side MountingYesYes

Process ConnectionOn/Off

End Ext/Matl Not Applicable HandwheelFlow Direction Bi-directional valve Max. stroke Time 1 Sec for Nominal inch

CS Yes (Mechanical)

Standard Enclosure MaterialLub & I so Valve Yes Local Position IndicatorType of Bonnet

Stainless SteelMaxseal IFR4 1/2" NPT

Packing Material PTFE or Equivalent Local Control CabinetBody/Bonnet Gasket Spiral Wound SS316L with Graphite Filler Mfr & Model

AC

TUA

TOR

Speed Control

Balanced/Unbalanced

Size RB Line Filter

REGU

LATO

R

Filter Reg & Gauge

Rated

Type BallASTM A193 Gr B7M / A194 Gr 2HM 1/2" NPT (F)

TRIM

YesYes

Characteristic On-Off Valve Supply Pressure Instrument Air

Solenoid Energised

Bolts / Nuts

63-SOV-6602A and 63-SOV-6602B

N/A Regulator Pressure Range 59,5 psi g (4,1 barg)N/A Relief Valve Set Pressure 87 psi g (6 barg)

ASCO NFET8327B2023/2 Way/316 SSValve OPEN

Seals VITON AED Voltage Rating 24VDC± 10%

Mfr. & Model

Enclosure Class / Material EEx'd'/316 SS

SPEC

IALS

/A

CC

ESSO

RIE

S

Conduit Connection SizeAir Accumulator N/A

Other seal VITON AED + GRAPHITE

Stem/Trunnion 17-4-PH + ENP 0,001"

Ball ASTM A350 LF2 + ENP 0,001"

Seat Ring Material ASTM A350 LF2 + ENP 0,001"

24V DC @ 1A

- Relief Valve N/A Type- Pressure Switch N/A QuantityValve Control Panel Required, SS 316, IP 65 Mfr & Model

IP 67Local Reset YesHydraulic Power Pack Not Required

LIM

IT S

WIT

CH

Proximity Type, Hermetical Seal, DPDT

Partial Stroking Facility

Type & Material

Tag Number

API 6FA

Hydrostatic / Pneumatic API 598/API 6DANSI/FCI Leakage Class High Tightness Class VIFire Test

- Capacity N/A

TEST

S

Process Connection

Required, Local Contacts Rating

Manual Reset

Enclosure Class / Material

SOLE

NO

ID V

ALV

E

Page 17: Cover pneumatic valves.pdf · 2013. 9. 10. · API 598/API 6D API 6FA ANSI/FCI Leakage Class High Tightness Class VI Fire Test Local Reset Yes TESTS Hydrostatic / Pneumatic ... Area

123456789

10 Units Normal Shut-Off11 mmscfd 248.3-1500 -

12 psig 74813 °F 55-120 -

14 psi -

15 psig16 °F -

17 Kg/m3 -

18 CP -

19 psi20 6321 6422 6523 6624 6725 6826 6927 7028 7129 7230 In 7331 Out 7432 7533 7634 7735 7836 7937 8038 8139 8240 8341 8442 8543 8644 8745 8846 8947 9048 9149 9250 9351 94 M20 x 1,552 95 N.A.53 9654 9755 98 4 Nos. 56 99 WESTLOCK 2649SBYN00042BEI-0057 10058 10159 10260 10361 10462 105

ZUEITINA OIL COMPANY

Data Sheets for ESD and Blowdown Valves- PRMS Area

API 6FA

Hydrostatic / Pneumatic

24V DC @ 1AHydraulic Power Pack Not Required IP 67

TEST

S

API 598/API 6DHigh Tightness Class VI

Yes

Fire TestANSI/FCI Leakage Class

Partial Stroking Facility Required, Local

LIM

IT S

WIT

CH

Enclosure Class / Material

Valve Control Panel Required, SS 316, IP 65 Mfr & Model

TypeQuantity

Local Reset

Air Accumulator N/A Manual Reset

Proximity Type, Hermetical Seal, DPDT- Pressure Switch

SPEC

IALS

/A

CC

ESSO

RIE

S

Conduit Connection Size

- Relief Valve N/A

Contacts Rating

N/A

Ball ASTM A350 LF2 + ENP 0,001" Tag Number

Other seal

SOLE

NO

ID V

ALV

E

VITON AED

- Capacity N/A

EEx'd'

Solenoid Energised Valve OPENVoltage Rating 24VDC± 10%Enclosure Class

ASTM A350 LF2 + ENP 0,001"

N/A

Stem/Trunnion 17-4-PH + ENP 0,001"

1/2 " NPT (F)

3/2 Way/316 SS

87 psi g (6 barg)

Filter Reg & Gauge Yes

Regulator Pressure Range 59,5 psi g (4,1 barg)Relief Valve Set Pressure

63-SOV-6004A and 63-SOV-6004BMfr. & ModelTR

IM

Type Ball

Characteristic On-Off Valve

SealsVITON AED + GRAPHITE

Seat Ring MaterialType & Material

Line Filter Yes

Rated N/A

Size RBSupply Pressure Instrument Air

ASCO NFET8327B202

Process Connection

Balanced/Unbalanced

Bolts / Nuts ASTM A193 Gr B7M / A194 Gr 2HM

REGU

LATO

R

Packing Material Stainless SteelBody/Bonnet Gasket Spiral Wound SS316L with Graphite Filler Mfr & Model Maxseal IFR4 1/2" NPT

PTFE or Equivalent Local Control Cabinet

CS Lub & Iso Valve Yes Local Position Indicator Yes (Mechanical)Type of Bonnet Standard Enclosure Material

NoFlow Direction Bi-directional valve Max. stroke Time 1 Sec for Nominal inchEnd Ext/Matl Not Applicable Handwheel

Top/Side Mounting

Fig Face Finish RF, Smooth Finish.ASME B1647 Series A Mechanical Limit Stop Yes

On/Off Yes36", RF, 600 lb Speed Control Yes

Mfr & Model

Liner Material/ID N/A Process ConnectionBody/Bonnet Matl ASTM A350 LF2 Maximum Shutoff DP 1292 psi

VALV

E B

OD

Y/B

ON

NET

Type Ball Valve (Reduced Bore) Actuating Medium

Size 36" ASME Class 600 lb

55 Actuator Break/Run Torque

End36", RF, 600 lb

Max. Press/Temp 1360 Psi / 200°F Valve Run/Seating Torque

Double block & bleed Required

8975 / 11668 Nm

Valvitalia LPS-20-940-CM34

AC

TUA

TOR

Inst. Air Air Failure position Fail Close

27849 NmValve Breakaway Torque

Mfr & Model

52265 /20211 Nm

Spring Return, air piston operated.Out 36" / 23.83 mm W.T Spring Material Carbon Steel

LIN

E Line Size & thicknessIn 36" / 23.83 mm W.T Type

Pipe Line Insulation

200Fluid Density 46.8

Critical Press Pc -

Fluid Viscosity @ OP. TEMP 0.01 to 0.02

Inlet Temperature 125 55Max. Shutoff Differential Pressure 1292Design Pressure 1360Design Temperature

248.3Inlet Pressure 1292 748

SER

VIC

E C

ON

DIT

ION

S

Fluid Natural GasPhase Gas

Maximum MinimumFlow Rate 1500

DATE 30/06/2010DOC. NO. 2010-0111 REV 0

GEN

ERA

L

Tag Number 63-XV-6004

Area Classification

PID Number 40227/PR/2/02/101Service Pig Reciever L-201 Area

Start-Up Bypass Valve 63-XV-6003 (Refer Sheet 5)

Line NumberA/essel No. NG-002-36"-E40

CLASS 1, ZONE 1, GAS GROUP IIA, T3Function Shut Down Valve

Page 18: Cover pneumatic valves.pdf · 2013. 9. 10. · API 598/API 6D API 6FA ANSI/FCI Leakage Class High Tightness Class VI Fire Test Local Reset Yes TESTS Hydrostatic / Pneumatic ... Area

123456789

10 Units Normal Shut-Off11 mmscfd 250- 1250 -

12 psig 72813 °F 60-95 -

14 psi -

15 psig16 °F -

17 Kg/m3 -

18 CP -

19 psi20 6321 6422 6523 6624 6725 6826 6927 7028 7129 7230 In 7331 Out 7432 7533 7634 7735 7836 7937 8038 8139 8240 8341 8442 8543 8644 8745 8846 8947 9048 9149 9250 9351 94 M20 x 1,552 95 N.A.53 9654 9755 98 4 Nos.56 99 WESTLOCK 2649SBYN00042BEI-00

57 10058 10159 10260 10361 10462 105

Line NumberA/essel No. NG-026-36"-E40

ZUEITINA OIL COMPANY

Data Sheets for ESD and Blowdown Valves- PRMS Area

DOC. NO. 2010-0111

Service

GEN

ERA

LShut Down Valve

REV 0 DATE 30/06/2010

Tripoli Branch

Area Classification CLASS 1, ZONE 1, GAS GROUP IIA, T3Start-Up Bypass Valve 63-XV-6304 (Refer Sheet 13)

Tag Number 63-XV-6301PID Number 40227/PR/2/02/125

FunctionSE

RVI

CE

CO

ND

ITIO

NS

Fluid Natural GasPhase Gas

Maximum MinimumFlow Rate

Max. Shutoff Differential Pressure 1292

0Inlet Pressure 1292 720

1250

Inlet Temperature 125 55

Fluid Density 46.8Fluid Viscosity @ OP. TEMP 0.01 to 0.02

Design Pressure 1360Design Temperature 200

LIN

E Line Size & thicknessIn 36" / 23.83 mm W.T TypeOut 36" / 23.83 mm W.T Spring Material Carbon Steel

Mfr & Model Valvitalia LPS-20-940-CM34

Critical Press Pc -

Spring Return, air piston operated.

Pipe Line Insulation

VALV

E B

OD

Y/B

ON

NET

Type Ball Valve (Reduced Bore) Actuating MediumDouble block & bleed Required Air Failure positionSize 36" ASME Class 600 lb Valve Breakaway Torque

Liner Material/ID N/A Process Connection

Inst. AirFail Close27849 Nm

Max. Press/Temp 1360 Psi / 200°F Valve Run/Seating Torque 8975 / 11668 NmMfr & Model 55 Actuator Break/Run TorqueBody/Bonnet Matl ASTM A350 LF2 Maximum Shutoff DP

End Conn.36", RF, 600 lb On/Off Yes36", RF, 600 lb Speed Control Yes

1 Sec for Nominal inch

52265 /20211 Nm1292 psiTop/Side Mounting

Yes

NoFlow Direction Bi-directional valve Max. stroke Time

Fig Face Finish RF, Smooth Finish.ASME B16.47 Series A Mechanical Limit StopEnd Ext/Matl Not Applicable Handwheel

Type of Bonnet Standard Enclosure MaterialLub & I so Valve Yes Local Position Indicator

AC

TUA

TOR

Packing Material PTFE or Equivalent Local Control Cabinet

CSYes (Mechanical)Stainless Steel

Body/Bonnet Gasket Spiral Wound SS316L with Graphite Filler

REGU

LATO

R

Mfr & Model Maxseal IFR4 1/2" NPTBolts / Nuts ASTM A193 Gr B7M / A194 Gr 2HM

TRIM

Type Ball Filter Reg & Gauge

Characteristic On-Off Valve Supply PressureBalanced/Unbalanced N/ARated

Size RB Line Filter YesInstrument Air

Process Connection 1/2" NPT (F)

87 psi g (6 barg)Regulator Pressure Range 59,5 psi g (4,1 barg)

Yes

N/A Relief Valve Set Pressure

24VDC ± 10%

Ball ASTM A350 LF2 Tag NumberMfr. & Model

Seat Ring Material Valve OPEN

Conduit Connection Size

63-SOV-6301A and 63-SOV-6301BASCO NFET8327B2023/2 Way/316 SS

Voltage RatingASTM A350 LF2 + ENP 0,001" Solenoid Energised

17-4-PH + ENP 0,001"

Required, LocalRequired, SS 316, IP 65

Seals VITON AEDOther seal VITON AED + GRAPHITE Enclosure Class / Material

SOLE

NO

ID V

ALV

E

Stem/Trunnion Type & Material

EEx'd'/316 SS

Quantity

SPEC

IALS

/A

CC

ESSO

RIE

S

Air Accumulator N/A Manual Reset- Capacity N/A

Mfr & ModelPartial Stroking Facility 24V DC @ 1A

- Relief Valve N/A Type Proximity Type, Hermetical Seal, DPDT

- Pressure Switch N/A

Contacts Rating

Hydrostatic / PneumaticANSI/FCI Leakage ClassFire Test API 6FATE

STS

API 598/API 6DHigh Tightness Class VI

Hydraulic Power Pack Not Required Enclosure Class / Material IP 67

LIM

IT S

WIT

CH

Local Reset Yes

Valve Control Panel

Page 19: Cover pneumatic valves.pdf · 2013. 9. 10. · API 598/API 6D API 6FA ANSI/FCI Leakage Class High Tightness Class VI Fire Test Local Reset Yes TESTS Hydrostatic / Pneumatic ... Area

123456789

10 Units Normal Shut-Off11 mmscfd 248.3-1500 -

12 psig 779-132413 °F 127 -

14 psi -

15 psig16 °F -

17 Kg/m3 -

18 CP -

19 psi20 6321 6422 6523 6624 6725 6826 6927 7028 7129 7230 In 7331 Out 7432 7533 7634 7735 7836 7937 8038 8139 8240 8341 8442 8543 8644 8745 8846 8947 9048 9149 9250 9351 94 M20 x 1,552 95 N.A.53 9654 9755 98 4 Nos.56 99 WESTLOCK 2649SBYN00042BEI-0057 10058 10159 10260 10361 10462 105

Line NumberA/essel No. NG-011-36"-F40

ZUEITINA OIL COMPANY

Data Sheets for ESD and Blowdown Valves- 103A Area

DOC. NO. 2010-0111

ServiceG

ENER

AL

Shut Down Valve

REV 0 DATE 30/06/2010

Compressor station outlet

Area Classification CLASS 1, ZONE 1, GAS GROUP IIA. T3Start-Up Bypass Valve 62-XV-6089 (Refer Sheet 21)

Tag Number 62-XV-6081PID Number 40227/PR/1/02/114

Function

SER

VIC

E C

ON

DIT

ION

S

Fluid Natural GasPhase Gas

Maximum MinimumFlow Rate

Max. Shutoff Differential Pressure 1338

248.3Inlet Pressure 1338 775

1500

Inlet Temperature 130 125

Fluid Density 44-78.3Fluid Viscosity @ OP. TEMP 0.01 to 0.02

Design Pressure 1480Design Temperature 300

LIN

E Line Size & ScheduleIn 36" / 23.83 mm W.T TypeOut 36" / 23.83 mm W.T Spring Material Carbon Steel

Mfr & Model Valvitalia LPS-20-940-CM34

Critical Press Pc -

Spring Return, air piston operated.

Pipe Line Insulation

VALV

E B

OD

Y/B

ON

NET

Type Ball Valve (Reduced Bore) Actuating Medium

Max. Press/Temp 1480 Psi / 200°F Valve Run/Seating Torque

Liner Material/ID N/A

Size 36" ASME Class 900 lb Valve Breakaway Torque 26632 Nm8975 / 11668 Nm

Inst. Air Double block & bleed Required Air Failure position Fail Close

Process Connection Top/Side MountingMaximum Shutoff DP 1338psi

Mfr & Model 55 Actuator Break/Run Torque 52265 /20211 NmBody/Bonnet Matl ASTM A350 LF2

Fig Face Finish RF, Smooth Finish.ASME B16.47 Series A

End

Mechanical Limit Stop Yes

36", RF, 900 lb On/Off YesSpeed Control Yes36", RF, 900 lb

Handwheel Not RequiredFlow Direction Bi-directional valve Max. stroke Time 1 Sec for Nominal inchEnd Ext/Matl Not Applicable

AC

TUA

TOR

Local Control Cabinet Stainless Steel

CSLub & Iso Valve Yes Local Position Indicator Required (Mechanical)Type of Bonnet Standard Enclosure Material

Packing MaterialMaxseal IFR4 1/2" NPT

Bolts / Nuts ASTM A193 Gr B7M / A194 Gr 2HM Process Connection 1/2" NPT (F)Body/Bonnet Gasket Spiral Wound SS316L with Graphite Filler Mfr & Model

Line Filter Required

TRIM

Type Ball

Characteristic On-Off Valve

Stem/Trunnion 17-4-PH + ENP 0,001"

Supply Pressure Instrument AirBalanced/Unbalanced N/A Regulator Pressure Range 59,5 psi g (4,1 barg)

REGU

LATO

R

Filter Reg & Gauge RequiredSize

Mfr. & Model ASCO NFET8327B202

87 psi g (6 barg)Ball ASTM A350 LF2+0,001" ENP Tag Number 62-SOV-6081A and 62-SOV-6081B

Rated N/A Relief Valve Set Pressure

Type & Material 3/2 Way/316 SSSeat Ring Material ASTM A350 LF2 + ENP 0,001" Solenoid Energised Valve OPEN

Conduit Connection Size

24VDC± 10%Other seal VITON AED + GRAPHITE Enclosure Class EEx'd'Seals VITON AED Voltage Rating

- Relief Valve N/A Type Proximity Type, Hermetical Seal, DPDT- Capacity N/A

SOLE

NO

ID V

ALV

E

Manual Reset

QuantityValve Control Panel Required, SS 316, IP 65 Mfr & Model- Pressure Switch N/A

24V DC @ 1AHydraulic Power Pack Not Required Enclosure Class / Material IP 67Partial Stroking Facility Required, Local Contacts Rating

ANSI/FCI Leakage Class

TEST

S

Hydrostatic / Pneumatic API 598/API 6D

SPEC

IALS

/ A

CC

ESSO

RIE

S

LIM

IT S

WIT

CH

Local Reset Yes

Air Accumulator N/A

High Tightness Class VIFire Test API 6FA

PTFE or Equivalent

RB

Page 20: Cover pneumatic valves.pdf · 2013. 9. 10. · API 598/API 6D API 6FA ANSI/FCI Leakage Class High Tightness Class VI Fire Test Local Reset Yes TESTS Hydrostatic / Pneumatic ... Area

123456789

10 Units Normal Shut-Off11 mmscfd 248.3-300 -

12 psig 779-132413 °F 130 -

14 psi -

15 psig16 °F -

17 Kg/m3 -

18 CP -

19 psi20 6321 6422 6523 6624 6725 6826 6927 7028 7129 7230 In 7331 Out 7432 7533 7634 7735 7836 7937 8038 8139 8240 8341 8442 8543 8644 8745 8846 8947 9048 9149 9250 9351 94 M20 x 1,552 95 Yes (ON PNEUMATIC VALVE)53 9654 9755 98 4 Nos.56 99 WESTLOCK 2649SBYN00042BEI-0057 10058 10159 10260 10361 10462 105

ZUEITINA OIL COMPANY

Data Sheets for ESD and Blowdown Valves- 103A Area

DOC. NO. 2010-0111 REV 0 DATE 30/06/2010

62-XV-6107PID Number 40227/PR/1/02/108Service Compressor K-10 Outlet

GEN

ERA

LTag Number

Area Classification CLASS 1, ZONE 1, GAS GROUP IIA, T3Start-Up Bypass Valve 62-XV-6103 (Refer Sheet 15)

Line Number/Vessel No. NG-102-20M-F40

Function Emergency Shut Down Valve

SER

VIC

E C

ON

DIT

ION

S

Fluid Natural GasPhase Gas

Maximum MinimumFlow Rate 300

Inlet Temperature 130 125Max. Shutoff Differential Pressure 1338

0Inlet Pressure 1338 775

Fluid Density 44-78.3Fluid Viscosity @ OP. TEMP 0.01 to 0.03

Design Pressure 1480Design Temperature 300

Critical Press Pc -

Spring Return, air piston operated.

Valve Breakaway Torque 5155 NmAir Failure position Fail Close

Size 20" ASME Class 900 lb1792 / 2329 Nm

Inst. Air Required

LIN

E Line Size & thicknessIn 20" / 14.27 mm WT TypeOut 20"/ 14.27 mm WT Carbon Steel

Mfr & Model Valvitalia LPS-16-530-CM29

Spring Material

Liner Material/IDASTM A350 LF2

Double block & bleed

Maximum Shutoff DPN/A Process Connection

20", RF, 900 lb On/Off Yes

VALV

E B

OD

Y/B

ON

NET

Type Ball Valve (Reduced Bore) Actuating Medium

Max. Press/Temp 1480 Psi / 300°F Valve Run/Seating TorqueMfr & Model 55 Actuator Break/Run Torque 13550 /4706 NmBody/Bonnet Matl 1338 psi

Fig Face Finish RF, Smooth Finish.ASME B16.5 Mechanical Limit Stop Yes

20", RF, 900 lb Speed Control Yes

Top/Side Mounting

Flow Direction Bi-directional valve Max. stroke Time 1 Sec for Nominal inchEnd Ext/Matl Not Applicable Handwheel Not Required

Yes Local Position Indicator Required (Mechanical)Type of Bonnet Standard Enclosure Material

Maxseal IFR4 1/2" NPTPacking Material PTFE or Equivalent Local Control Cabinet Stainless Steel

AC

TUA

TOR

Pipe Line Insulation

End

CS Lub & Iso Valve

Bolts / Nuts ASTM A193 Gr B7M / A194 Gr 2HM Process ConnectionBody/Bonnet Gasket Spiral Wound SS316L with Graphite Filler Mfr & Model

Instrument Air

1/2 " NPT (F)

TRIM

Type Ball Filter Reg & Gauge RequiredSize RB Line Filter

87 psi g (6 barg)

REGU

LATO

R

Balanced/Unbalanced N/A Regulator Pressure Range 59,5 psi g (4,1 barg)

RequiredCharacteristic On-Off Valve Supply Pressure

Ball ASTM A350 LF2+0,001" ENP Tag NumberRated N/A Relief Valve Set Pressure

Stem/Trunnion 17-4-PH + ENP 0,001" Type & Material

Seals

Mfr. & Model

Conduit Connection Size

Seat Ring Material ASTM A350 LF2 + ENP 0,001" Solenoid Energised

Other seal VITON AED + GRAPHITE Enclosure Class / MaterialVITON AED

Air Accumulator N/A Manual Reset

Voltage Rating

- Capacity N/A

SOLE

NO

ID V

ALV

E

EEx'd'/316 SS

Valve OPEN

62-SOV-6107A and 62-SOV-6107B

24VDC± 10%

3/2 Way/316 SSASCO NFET8327B202

Mfr & Model

Proximity Type, Hermetical Seal, DPDT

- Pressure Switch N/A Quantity- Relief Valve N/A Type

Valve Control Panel Required, SS 316, IP 6524V DC @ 1A

Hydraulic Power Pack Not Required Enclosure Class / Material IP 67Partial Stroking Facility Required, Local Contacts Rating

Hydrostatic / Pneumatic API 598/API 6DLocal Reset N.A.

SPEC

IALS

/ A

CC

ESSO

RIE

S

LIM

IT S

WIT

CH

TEST

S High Tightness Class VIFire Test API 6FAANSI/FCI Leakage Class

Page 21: Cover pneumatic valves.pdf · 2013. 9. 10. · API 598/API 6D API 6FA ANSI/FCI Leakage Class High Tightness Class VI Fire Test Local Reset Yes TESTS Hydrostatic / Pneumatic ... Area

123456789

10 Units Normal Shut-Off11 mmscfd 248.3-300 -

12 psig 42013 °F 10014 psi -

15 psig16 °F -

17 Kg/m3 -

18 CP -

19 psi20 6321 6422 6523 6624 6725 6826 6927 7028 7129 7230 In 7331 Out 7432 7533 7634 7735 7836 7937 8038 8139 8240 8341 8442 8543 8644 8745 8846 8947 9048 9149 9250 9351 94 M20 x 1,552 9553 9654 9755 98 4 Nos.56 99 WESTLOCK 2649SBYN00042BEI-0057 10058 10159 10260 10361 10462 105

REV 0 DATE 30/06/2010

GEN

ERA

LTag Number 62-XV-6108PID Number 40227/PR/1/02/108

CLASS 1, ZONE 1, GAS GROUP HA, T3

Service

Yes (ON PNEUMATIC VALVE)

ZUEITINA OIL COMPANY

Data Sheets for ESD and Blowdown Valves- 103A Area

DOC. NO. 2010-0111

Minimum

Function Emergency Shut Down ValveArea Classification

Compressor K-10 InletLine NumberA/essel No. NG-101-24"-E41

415

Start-Up Bypass Valve 62-XV-6101 (Refer Sheet 13)

SER

VIC

E C

ON

DIT

ION

S

Fluid Natural GasPhase Gas

Maximum

Inlet Temperature 101 92Max. Shutoff Differential Pressure 525

Flow Rate 300 0Inlet Pressure 475

Fluid Density 25.2Fluid Viscosity @ OP. TEMP 0.01

Design Pressure 1360Design Temperature 200

LIN

E Line Size & thicknessIn 24" / 15.88 mm WT Type

N/A Process Connection

24" ASME Class 600 lb

Mfr & Model

Critical Press Pc -

Valvitalia LPS-16-530-CM29

Inst. Air

Spring Return, air piston operated.Out 24" / 15.88 mm WT Spring Material Carbon Steel

VALV

E B

OD

Y/B

ON

NET

Type Ball Valve (Reduced Bore) Actuating MediumDouble block & bleed Required

Fig Face Finish RF, Smooth Finish.ASME B16.5

Air Failure position

Liner Material/ID Top/Side Mounting

Mfr & Model

5627 NmMax. Press/Temp 1360 Psi / 200°F Valve Run/Seating Torque 2478 / 3221 NmSize

Fail CloseValve Breakaway Torque

13550 /4706 NmBody/Bonnet Matl ASTM A350 LF2 Maximum Shutoff DP 525 psi

55 Actuator Break/Run Torque

Yes

24", RF, 600 lb On/Off Yes24", RF, 600 lb Speed Control Yes

Mechanical Limit Stop

Bi-directional valve Max. stroke Time 1 Sec for Nominal inchEnd Ext/Matl Not Applicable Handwheel Not RequiredFlow Direction

Lub & I so Valve Yes Local Position Indicator Required (Mechanical)Type of Bonnet Standard Enclosure Material CS

Body/Bonnet Gasket Spiral Wound SS316L with Graphite Filler Mfr & Model Maxseal IFR4 1/2" NPTPacking Material PTFE or Equivalent Local Control Cabinet Stainless Steel

trim

Type Ball Filter Reg & Gauge

Characteristic On-Off Valve Supply Pressure

Seals VITON AED Voltage Rating

Instrument Air

1/2 " NPT (F)Bolts / Nuts ASTM A193 Gr B7M / A194 Gr 2HM Process ConnectionRequired

Size RB Line Filter Required

59,5 psi g (4,1 barg)Rated N/A Relief Valve Set Pressure 87 psi g (6 barg)Balanced/Unbalanced N/A Regulator Pressure Range

62-SOV-6108A and 62-SOV-6108BMfr. & Model ASCO NFET8327B202

Ball ASTM A350 LF2 + ENP 0,001" Tag Number

3/2 Way/316 SSSeat Ring Material ASTM A350 LF2 + ENP 0,001" Solenoid Energised Valve OPENStem/Trunnion 17-4-PH + ENP 0,001" Type & Material

24VDC± 10%Other seal VITON AED+GRAPHITE Enclosure Class / Material EEx'd'/316 SS

Conduit Connection SizeAir Accumulator N/A Manual Reset- Capacity N/A

24V DC @ 1A

Proximity Type, Hermetical Seal, DPDT- Pressure Switch N/A Quantity- Relief Valve N/A Type

Valve Control Panel Required, SS 316, IP 65 Mfr & ModelPartial Stroking Facility Required, Local Contacts Rating

IP 67Local Reset N.A.Hydraulic Power Pack Not Required Enclosure Class / Material

API 6FAANSI/FCI Leakage Class High Tightness Class VIFire TestTE

STS

Hydrostatic / Pneumatic

AC

TUA

TOR

Pipe Line Insulation

EndRE

GULA

TOR

SOLE

NO

ID V

ALV

E

SPEC

IALS

/ A

CC

ESSO

RIE

S

LIM

IT S

WIT

CH

API 598/API 6D

Page 22: Cover pneumatic valves.pdf · 2013. 9. 10. · API 598/API 6D API 6FA ANSI/FCI Leakage Class High Tightness Class VI Fire Test Local Reset Yes TESTS Hydrostatic / Pneumatic ... Area

123456789

10 Units Normal Shut-Off11 mmscfd 248.3-300 -

12 psig 779-132413 °F 130 -

14 psi -

15 psig16 °F -

17 Kg/m3 -

18 CP -

19 psi20 6321 6422 6523 6624 6725 6826 6927 7028 7129 7230 In 7331 Out 7432 7533 7634 7735 7836 7937 8038 8139 8240 8341 8442 8543 8644 8745 8846 8947 9048 9149 9250 9351 94 M20 x 1,552 95 Yes (ON PNEUMATIC VALVE)53 9654 9755 98 4 Nos.56 99 WESTLOCK 2649SBYN00042BEI-0057 10058 10159 10260 10361 10462 105

Line NumberA/essel No. NG-105-20"-F40

ZUEITINA OIL COMPANY

Data Sheets for ESD and Blowdown Valves- 103A Area

DOC. NO. 2010-0111

ServiceG

ENER

AL

Emergency Shut Down Valve

REV 0 DATE 30/06/2010

Compressor K-20 Outlet

Area Classification CLASS 1, ZONE 1, GAS GROUP IIA, T3Start-Up Bypass Valve 62-XV-6203(Refer Sheet 19)

Tag Number 62-XV-6207PID Number 40227/PR/1/02/109

Function

SER

VIC

E C

ON

DIT

ION

S

Fluid Natural GasPhase Gas

Maximum MinimumFlow Rate

Max. Shutoff Differential Pressure 1338

0Inlet Pressure 1338 775

300

Inlet Temperature 130 125

Fluid Density 44-78.3Fluid Viscosity @ OP. TEMP 0.01 to 0.03

Design Pressure 1480Design Temperature 300

LIN

E Line Size & thicknessIn 20" /14.27 mm WT TypeOut 20" /14.27 mm WT Spring Material Carbon Steel

Mfr & Model Valvitalia LPS-16-530-CM29

Critical Press Pc -

Spring Return, air piston operated.

VALV

E B

OD

Y/BO

NN

ET

Type Ball Valve (Reduced Bore) Actuating Medium

Size 20" ASME Class 900 lb Valve Breakaway Torque

Mfr & Model 55

Liner Material/ID

5155 NmMax. Press/Temp 1480 Psi / 200°F Valve Run/Seating Torque 1792 / 2329 Nm

Inst. Air Double block & bleed Required Air Failure position Fail Close

1 Sec for Nominal inchEnd Ext/Matl Not Applicable Handwheel

Top/Side Mounting

13550 /4706 Nm

20", RF, 900 lb On/Off YesN/A Process Connection

ASTM A350 LF2 Maximum Shutoff DP 1338 psi

Yes

Not Required

20", RF, 900 lb Speed Control Yes

RF, Smooth Finish,ASME B16.5

CSType of Bonnet Standard Enclosure Material

AC

TUA

TOR

Pipe Line Insulation

Bi-directional valve Max. stroke Time

End

Mechanical Limit StopFig Face Finish

Actuator Break/Run Torque

Flow Direction

Body/Bonnet Matl

Mfr & Model Maxseal IFR4 1/2" NPT

Local Position Indicator Required (Mechanical)Local Control Cabinet Stainless Steel

Lub & Iso Valve Yes

Body/Bonnet Gasket Spiral Wound SS316L with Graphite FillerPacking Material PTFE or Equivalent

On-Off Valve Supply Pressure

Rated N/A

Bolts / Nuts ASTM A193 Gr B7M / A194 Gr 2HM Process ConnectionRequired1/2" NPT (F)

TRIM

Type Ball Filter Reg & Gauge

Characteristic

Mfr. & ModelStem/Trunnion 17-4-PH + ENP 0,001"

Instrument AirBalanced/Unbalanced N/A Regulator Pressure Range 59,5 psi g (4,1 barg)

REGU

LATO

R

Size RB Line Filter Required

Type & Material 3/2 Way/316 SS

87 psi g (6 barg)Ball ASTM A350 LF2+0,001" ENP Tag Number 62-SOV-6207A and 62-SOV-6207B

Relief Valve Set Pressure

ASCO NFET8327B202

EEx'd'/316 SS

Valve OPENSeals VITON AED Voltage Rating 24VDC± 10%Seat Ring Material ASTM A350 LF2 + ENP 0,001" Solenoid Energised

Other seal VITON AED + GRAPHITE Enclosure Class / Material

- Capacity N/A- Relief Valve N/A Type Proximity Type, Hermetical Seal, DPDT

SOLE

NO

ID V

ALV

E

Conduit Connection SizeAir Accumulator N/A Manual Reset

QuantityValve Control Panel Required, SS 316, IP 65 Mfr & Model- Pressure Switch N/A

Contacts Rating 24V DC @ 1A

Fire Test API 6FA

Enclosure Class / Material IP 67

Hydrostatic / Pneumatic API 598/API 6DANSI/FCI Leakage Class High Tightness Class VI

Local Reset N.A.

SPEC

IALS

/ A

CC

ESSO

RIE

S

LIM

IT S

WIT

CH

TEST

S

Partial Stroking Facility Required, LocalHydraulic Power Pack Not Required

Page 23: Cover pneumatic valves.pdf · 2013. 9. 10. · API 598/API 6D API 6FA ANSI/FCI Leakage Class High Tightness Class VI Fire Test Local Reset Yes TESTS Hydrostatic / Pneumatic ... Area

123456789

10 Units Normal Shut-Off11 mmscfd 248.3-300 -

12 psig 42013 °F 100 -

14 psi -

15 psig16 °F -

17 Kg/m3 -

18 CP -

19 psi20 6321 6422 6523 6624 6725 6826 6927 7028 7129 7230 In 7331 Out 7432 7533 7634 7735 7836 7937 8038 8139 8240 8341 8442 8543 8644 8745 8846 8947 9048 9149 9250 9351 94 M20 x 1,552 95 Yes (ON PNEUMATIC VALVE)53 9654 9755 98 4 Nos. 56 99 WESTLOCK 2649SBYN00042BEI-0057 10058 10159 10260 10361 10462 105

GEN

ERA

L

ZUEITINA OIL COMPANY

Data Sheets for ESD and Blowdown Valves- 103A Area

DOC. NO. 2010-0111 REV 0 DATE 30/06/2010

Tag Number

Line NumberA/essel No. NG-102-24"-E41Function Emergency Shut Down Valve

62-XV-6208PID Number 40227/PR/1/02/109Service Compressor K-20 Inlet

Maximum MinimumFlow Rate 300 0

Area Classification CLASS 1, ZONE 1, GAS GROUP IIA, T3Start-Up Bypass Valve 62-XV-6201 (Refer Sheet 17)

Inlet Pressure 475 415

SER

VIC

E C

ON

DIT

ION

S

Fluid Natural GasPhase Gas

Design Pressure 1360Design Temperature 200

Inlet Temperature 101 92Max. Shutoff Differential Pressure 525

LIN

E Line Size & thicknessIn 24" /15.88 mm WT TypeOut 24" /15.88 mm WT Spring Material

Critical Press Pc -

Spring Return, air piston operated.

Required Air Failure positionType Ball Valve (Reduced Bore) Actuating Medium

Fluid Density 25.2Fluid Viscosity @ OP. TEMP 0.01

Mfr & Model 55Max. Press/Temp 1360 Psi / 200°F

Body/Bonnet Matl

Carbon SteelMfr & Model Valvitalia LPS-16-530-CM29

Inst. Air Double block & bleed Fail Close

5627 Nm24" ASME Class 600 lbSize Valve Breakaway Torque

Process Connection Top/Side Mounting

Actuator Break/Run Torque 13550 /4706 Nm2478 / 3221 NmValve Run/Seating Torque

ASTM A350 LF2 Maximum Shutoff DP 525 psi

On/Off Yes24", RF, 600 lbSpeed Control Yes24", RF, 600 lb

1 Sec for Nominal inchHandwheel Not RequiredMechanical Limit Stop Yes

Max. stroke Time

Required (Mechanical)Yes Local Position IndicatorStandard Enclosure Material CS

Local Control Cabinet Stainless Steel

AC

TUA

TOR

Pipe Line Insulation

Liner Material/ID

End

End Ext/Matl Not ApplicableFlow Direction Bi-directional valve

Process Connection 1/2" NPT (F)Body/Bonnet Gasket Spiral Wound SS316L with Graphite Filler Mfr & Model Maxseal IFR4 1/2" NPT

ASTM A193 Gr B7M / A194 Gr 2HM

Filter Reg & Gauge RequiredSize RB Line Filter RequiredType Ball

Supply Pressure Instrument AirBalanced/Unbalanced N/A Regulator Pressure Range 59,5 psi g (4,1 barg)Characteristic On-Off Valve

87 psi g (6 barg)Ball ASTM A350 LF2 + ENP 0,001" Tag Number 62-SOV-6208A and 62-SOV-6208B

Rated N/A Relief Valve Set Pressure

REGU

LATO

RBolts / Nuts

Mfr. & Model ASCO NFET8327B202Stem/Trunnion 17-4-PH + ENP 0,001" Type & Material 3/2 Way/316 SS

Valve OPENSeals VITON AED Voltage Rating 24VDC± 10%Seat Ring Material ASTM A350 LF2 + ENP 0,001" Solenoid Energised

Conduit Connection SizeVITON AED+GRAPHITE Enclosure Class / Material

- Capacity N/AAir Accumulator N/A Manual Reset

- Relief Valve N/A Type Proximity Type, Hermetical Seal, DPDT

SOLE

NO

ID V

ALV

E

Other seal EEx'd'/316 SS

Fire Test

24V DC @ 1AEnclosure Class / Material IP 67Contacts Rating

API 598/API 6D

TEST

S

Hydrostatic / Pneumatic

API 6FAANSI/FCI Leakage Class High Tightness Class VI

Mfr & ModelPartial Stroking Facility Required, Local

LIM

IT S

WIT

CH

- Pressure Switch N/A Quantity

Hydraulic Power Pack Not RequiredLocal Reset N.A.

Valve Control Panel Required, SS 316, IP 65

Fig Face Finish RF, Smooth Finish.ASME B16.5

SPEC

IALS

/ A

CC

ESSO

RIE

STR

IM

Packing Material PTFE or EquivalentLub & I so ValveType of Bonnet

VALV

E B

OD

Y/B

ON

NET

N/A

Page 24: Cover pneumatic valves.pdf · 2013. 9. 10. · API 598/API 6D API 6FA ANSI/FCI Leakage Class High Tightness Class VI Fire Test Local Reset Yes TESTS Hydrostatic / Pneumatic ... Area

123456789

10 Units Normal Shut-Off11 mmscfd HOLD -

12 psig 47013 °F 100 -

14 psi -

15 psig16 °F -

17 Kg/m3 -

18 CP -

19 psi20 6321 6422 6523 6624 6725 6826 6927 7028 7129 7230 In 7331 Out 7432 7533 7634 7735 7836 7937 8038 8139 8240 8341 8442 8543 8644 8745 8846 8947 9048 9149 9250 9351 94 M20 x 1,552 95 Yes (ON PNEUMATIC VALVE)53 9654 9755 98 4 Nos. 56 99 WESTLOCK 2649SBYN00042BEI-0057 10058 10159 10260 10361 10462 105

ZUEITINA OIL COMPANY

Data Sheets for ESD and Blowdown Valves- 103A Area

DOC. NO. 2010-0111 | REV 0 DATE 30/06/2010

GEN

ERA

L

Tag Number 62-XV-6902PID Number 40227/PR/1/02/002Service Start-Up Bypass Valve for 62-XV-6901Line Number/Vessel No. NG-001-24"-E41Function Shut Down - Start-up Bypass ValveArea Classification CLASS 1, ZONE 1, GAS GROUP HA, T3Start-Up Bypass ValveFluid Natural GasPhase Gas

Maximum Minimum

Max. Shutoff Differential Pressure 699

Flow Rate HOLD HOLD

Design Pressure 1360

Inlet Pressure 635 430Inlet Temperature 100 98

Out 2" / SCH 80 Spring Material

Design Temperature 200Fluid Density 25.2

0.01Critical Press Pc -

Spring Return, air piston operated.

SER

VIC

E C

ON

DIT

ION

S

Carbon Steel

LIN

E Line Size & thicknessIn 2" / SCH 80 Type

Pipe Line Insulation N/A. Valvitalia LPS-05-135-CM04Mfr & Model

Fluid Viscosity @ OP. TEMP

VALV

E B

OD

Y/B

ON

NET

Type Ball Valve (Reduced Bore) Actuating Medium

Size 2" ASME Class 600 lb Valve Breakaway Torque

Mfr & Model 54 Actuator Break/Run Torque

73 NmMax. Press/Temp 1333 Psi / 248 °F Valve Run/Seating Torque 36 / 51 Nm

Inst. AirDouble block & bleed Required Air Failure position Fail Close

Liner Material/ID N/A Process Connection Top/Side Mounting

245 /84 NmBody/Bonnet Matl ASTM A350 LF2 Maximum Shutoff DP 699 psi

End2", RF, 600 lb Speed Control Yes

Flow Direction

Yes

End Ext/Matl Not Applicable Handwheel Not RequiredFig Face Finish RF, Smooth Finish.ASME B16.5 Mechanical Limit Stop

Yes Local Position Indicator

AC

TUA

TOR

1 Sec for Nominal inchBi-directional valve Max. stroke Time

Required (Mechanical)

2", RF, 600 lb On/Off Yes

Type of Bonnet Standard Enclosure Material CS

Body/Bonnet Gasket Spiral Wound SS316L with Graphite Filler Mfr & Model MAXSEAL IFR3 1/4" NPTPacking Material PTFE or Equivalent Local Control Cabinet Stainless Steel

59,5 psi g (4,1 barg)

1/2" NPT (F)Required

Lub & Iso Valve

RB Line Filter Required

Bolts / Nuts ASTM A193 Gr B7M / A194 Gr 2HM Process Connection

Supply PressureNA Regulator Pressure Range

87 psi g (6 barg)NA Relief Valve Set PressureRated

REGU

LATO

R

Instrument AirBalanced/Unbalanced

Type Ball Filter Reg & Gauge

Mfr. & Model ASCO NFET8327B202Ball ASTM A182 F316 Tag Number 62-SOV-6902A and 62-SOV-6902B

Solenoid Energised Valve OPENStem/Trunnion 17-4-PH / ASTM A182 F316 Type & Material 3/2 Way/316 SSSeat Ring Material ASTM A182 F316

Enclosure Class / Material EEx'd'/316 SSSeals DEVLON Voltage Rating 24VDC± 10%

Quantity

Conduit Connection SizeAir Accumulator N/A Manual Reset- Capacity N/A

SOLE

NO

ID V

ALV

E

Mfr & Model

- Relief Valve N/A

LIM

IT S

WIT

CH Type Proximity Type, Hermetical Seal, DPDT

- Pressure Switch N/A

Contacts Rating 24V DC @ 1AHydraulic Power Pack Not Required Enclosure Class / Material IP 67Partial Stroking Facility Not Required

Hydrostatic / Pneumatic API 598/API 6DLocal Reset N.A.

API 6FATEST

S

Fire Test

SPEC

IALS

/ A

CC

ESSO

RIE

S

Valve Control Panel Required, SS 316, IP 65

Other seal VITON AED + GRAPHITE

TRIM

SizeCharacteristic On-Off Valve

ANSI/FCI Leakage Class High Tightness Class VI

Page 25: Cover pneumatic valves.pdf · 2013. 9. 10. · API 598/API 6D API 6FA ANSI/FCI Leakage Class High Tightness Class VI Fire Test Local Reset Yes TESTS Hydrostatic / Pneumatic ... Area

123456789

10 Units Normal Shut-Off11 mmscfd HOLD -

12 psig 43013 °F 100 -

14 psi -

15 psig16 °F -

17 Kg/m3 -

18 CP -

19 psi20 6321 6422 6523 6624 6725 6826 6927 7028 7129 7230 In 7331 Out 7432 7533 7634 7735 7836 7937 8038 8139 8240 8341 8442 8543 8644 8745 8846 8947 9048 9149 9250 9351 94 M20 x 1,552 95 Yes (ON PNEUMATIC VALVE)53 9654 9755 98 4 Nos.56 99 WESTLOCK 2649SBYN00042BEI-0057 10058 10159 10260 10361 10462 105

Line NumberA/essel No. NG-005-24"-E41

ZUEITINA OIL COMPANY

Data Sheets for ESD and Blowdown Valves- 103A Area

DOC. NO. 2010-0111

ServiceG

ENER

AL

Shut Down - Start-up Bypass Valve

REV 0 DATE 30/06/2010

Start-Up Bypass Valve for 62-XV-6010

Area Classification CLASS 1, ZONE 1, GAS GROUP HA, T3Start-Up Bypass Valve

Tag Number 62-XV-6012PID Number 40227/PR/1/02/101

Function

SER

VIC

E C

ON

DIT

ION

S

Fluid Natural GasPhase Gas

Maximum MinimumFlow Rate

Max. Shutoff Differential Pressure 485

HOLDInlet Pressure 485 420

HOLD

Inlet Temperature 101 95

Fluid Density 25.2Fluid Viscosity @ OP. TEMP 0.01

Design Pressure 1360Design Temperature 200

Valvitalia LPS-05-135-CM04

Critical Press Pc -

Spring Return, air piston operated.

Pipe Line InsulationSpring Material

LIN

E Line Size & thicknessIn 2" / SCH 80 TypeOut 2" / SCH 80

VALV

E B

OD

Y/B

ON

NET

Type Ball Valve (Reduced Bore) Actuating Medium

Size 2" ASME Class 600 lb Valve Breakaway Torque

Mfr & Model 54 Actuator Break/Run TorqueMax. Press/Temp 1333 Psi / 248°F Valve Run/Seating Torque 36 / 51 Nm

Inst. Air Double block & bleed Required Air Failure position Fail Close

Yes

Liner Material/ID N/A Process Connection Top/Side Mounting2", RF, 600 lb On/Off Yes2", RF, 600 lb Speed Control

245 /84 NmBody/Bonnet Matl ASTM A350 LF2 Maximum Shutoff DP 485 psi

CS

Not Applicable Handwheel Not Required1 Sec for Nominal inch

AC

TUA

TOR

73 Nm

Carbon SteelMfr & Model

Max. stroke Time

Required (Mechanical)

Mechanical Limit Stop Yes

Enclosure Material

End

End Ext/MatlFlow Direction Bi-directional valve

Fig Face Finish RF, Smooth Finish,ASME B16.5

Lub & Iso Valve Yes Local Position IndicatorType of Bonnet Standard

Bolts / Nuts ASTM A193 Gr B7M / A194 Gr 2HM Process Connection 1/2"NPT(F)

Packing Material PTFE or Equivalent Local Control Cabinet Stainless SteelBody/Bonnet Gasket Spiral Wound SS316L with Graphite Filler Mfr & Model

TRIM

Type Ball Filter Reg & Gauge

Characteristic On-Off Valve Supply PressureRegulator Pressure Range 59,5 psi g (4,1 barg)

REGU

LATO

R

Line Filter RequiredInstrument Air

87 psi g (6 barg)

Required

MAXSEAL IFR3 1/4" NPT

Size RB

17-4-PH / ASTM A182 F316 Type & Material

Relief Valve Set PressureBall ASTM A182 F316 Tag Number

Balanced/Unbalanced N/A

62-SOV-6012A and 62-SOV-6012BRated N/A

Seat Ring Material ASTM A182 F316 Solenoid Energised Valve OPEN

Mfr. & Model3/2 Way/316 SSStem/TrunnionASCO NFET8327B202

24VDC ± 10%DEVLON Voltage RatingSealsOther seal VITON AED + GRAPHITE Enclosure Class / Material EEx'd' / 316 SS

Valve Control Panel Required, SS 316, IP 65 Mfr & Model- Pressure Switch N/A Quantity

Conduit Connection Size

- Capacity N/A

Partial Stroking Facility Not Required Contacts Rating 24V DC @ 1A

- Relief Valve N/A Type Proximity Type, Hermetical Seal, DPDT

SOLE

NO

ID V

ALV

E

Air Accumulator N/A Manual Reset

Local Reset N.A.Hydraulic Power Pack Not Required Enclosure Class / Material IP 67

TEST

S

Hydrostatic / Pneumatic

Fire Test

SPEC

IALS

/ A

CC

ESSO

RIE

S

LIM

IT S

WIT

CH

API 598/APl 6D

API 6FAANSI/FCI Leakage Class High Tightness Class VI

Page 26: Cover pneumatic valves.pdf · 2013. 9. 10. · API 598/API 6D API 6FA ANSI/FCI Leakage Class High Tightness Class VI Fire Test Local Reset Yes TESTS Hydrostatic / Pneumatic ... Area

123456789

10 Units Normal Shut-Off11 mmscfd HOLD -

12 psig 42513 °F 100 -

14 psi -

15 psig16 °F -

17 Kg/m3 -

18 CP -

19 psi20 6321 6422 6523 6624 6725 6826 6927 7028 7129 7230 In 7331 Out 7432 7533 7634 7735 7836 7937 8038 8139 8240 8341 8442 8543 8644 8745 8846 8947 9048 9149 9250 9351 94 M20 x 1,552 95 Yes (ON PNEUMATIC VALVE)53 9654 9755 98 4 Nos.56 99 WESTLOCK 2649SBYN00042BEI-0057 10058 10159 10260 10361 10462 105

Line NumberA/essel No. NG-115-6"-E41

ZUEITINA OIL COMPANY

Data Sheets for ESD and Blowdown Valves- 103A Area

DOC. NO. 2010-0111

ServiceG

ENER

AL

Emergency Shut Down Valve

REV 0 DATE 30/06/2010

Filter Seperator C-10 to Fuel gas

Area Classification CLASS 1, ZONE 1, GAS GROUP IIA, T3Start-Up Bypass Valve 62-XV-6075 (Refer Sheet 9)

Tag Number 62-XV-6074PID Number 40227/PR/1/02/107

Function

SER

VIC

E C

ON

DIT

ION

S

Fluid Natural GasPhase Gas

Maximum MinimumFlow Rate

Max. Shutoff Differential Pressure 475

HOLDInlet Pressure 475 420

HOLD

Inlet Temperature 101 94

Fluid Density 25.2Fluid Viscosity @ OP. TEMP 0.01

Design Pressure 1360Design Temperature 200

Fail Close

Critical Press Pc -

Inst. Air

Spring Return, air piston operated.Carbon SteelValvitalia LPS-07-280-CM12

LIN

E Line Size & thicknessIn 6" / SCH 80 TypeOut 6" / SCH 80 Spring Material

Mfr & Model

VALV

E B

OD

Y/B

ON

NET

Type Ball Valve (Reduced Bore) Actuating MediumDouble block & bleed Required Air Failure positionSize 6" ASME Class 600 lb

Liner Material/ID

Valve Breakaway Torque 545 NmMax. Press/Temp 1333 Psi / 248°F Valve Run/Seating Torque 273 / 382 Nm

1290 /626 NmBody/Bonnet Matl ASTM A350 LF2 Maximum Shutoff DP 475 psiMfr & Model 54 Actuator Break/Run Torque

Top/Side Mounting6", RF, 600 lb On/Off Yes

N/A Process Connection

Packing Material PTFE or Equivalent Local Control Cabinet

Yes

Fig Face Finish RF, Smooth Finish.ASME B16.5 Mechanical Limit Stop Yes

6", RF, 600 lb Speed Control

Not RequiredFlow Direction Bi-directional valve Max. stroke Time 1 Sec for Nominal inchEnd Ext/Matl Not Applicable Handwheel

CSLub & I so Valve Yes Local Position Indicator Required (Mechanical)

Standard Enclosure MaterialType of Bonnet

AC

TUA

TOR

Pipe Line Insulation

Stainless SteelBody/Bonnet Gasket Spiral Wound SS316L with Graphite Filler

REGU

LATO

R

Mfr & Model MAXSEAL IFR3 1/4" NPTBolts / Nuts ASTM A193 Gr B7M / A194 Gr 2HM Process Connection 1/2" NPT (F)

TRIM

Type Ball Filter Reg & Gauge

Characteristic On-Off Valve Supply Pressure

Rated N/A Relief Valve Set Pressure 87 psi g (6 barg)Ball ASTM A182 F316

RequiredSize RB Line Filter Required

Instrument Air Balanced/Unbalanced N/A Regulator Pressure Range 59,5 psi g (4,1 barg)

Solenoid Energised Valve OPEN

Mfr. & Model ASCO NFET8327B202Type & Material 3/2 Way/316 SS

Tag Number 62-SOV-6074A and 62-SOV-6074B

EEx'd'/316 SSSeals VITON AED Voltage Rating 24VDC±10%Other seal VITON AED + GRAPHITE Enclosure Class / Material

Air Accumulator N/A Manual ResetConduit Connection Size

- Capacity N/A- Relief Valve N/A Type Proximity Type, Hermetical Seal, DPDT- Pressure Switch N/A Quantity

Partial Stroking Facility Required, Local Contacts Rating 24V DC @ 1AValve Control Panel Required, SS 316, IP 65 Mfr & Model

Local Reset N.A.Hydraulic Power Pack Not Required Enclosure Class / Material IP 67

Fire Test API 6FATEST

S

Hydrostatic / Pneumatic

SPEC

IALS

/ A

CC

ESSO

RIE

S

LIM

IT S

WIT

CH

API 598/API 6DANSI/FCI Leakage Class High Tightness Class VI

EndSO

LEN

OID

VA

LVE

Seat Ring Material ASTM A182 F316Stem/Trunnion 17-4-PH / ASTM A182 F316

Page 27: Cover pneumatic valves.pdf · 2013. 9. 10. · API 598/API 6D API 6FA ANSI/FCI Leakage Class High Tightness Class VI Fire Test Local Reset Yes TESTS Hydrostatic / Pneumatic ... Area

123456789

10 Units Normal Shut-Off11 mmscfd HOLD -

12 psig 42513 °F 100 -

14 psi -

15 psig16 °F -

17 Kg/m3 -

18 CP -

19 psi20 6321 6422 6523 6624 6725 6826 6927 7028 7129 7230 In 7331 Out 7432 7533 7634 7735 7836 7937 8038 8139 8240 8341 8442 8543 8644 8745 8846 8947 9048 9149 9250 9351 94 M20 x 1,552 95 Yes (ON PNEUMATIC VALVE)53 9654 9755 98 4 Nos.56 99 WESTLOCK 2649SBYN00042BEI-0057 10058 10159 10260 10361 10462 105

Line NumberA/essel No. NG-115-6"-E41

ZUEITINA OIL COMPANY

Data Sheets for ESD and Blowdown Valves- 103A Area

DOC. NO. 2010-0111

ServiceG

ENER

AL

Shut Down - Start-up Bypass Valve

REV 0 DATE 30/06/2010

Start-Up Bypass Valve for 62-XV-6074

Area Classification CLASS 1, ZONE 1, GAS GROUP IIA, T3Start-Up Bypass Valve

Tag Number 62-XV-6075PID Number 40227/PR/1/02/107

Function

SER

VIC

E C

ON

DIT

ION

S

Fluid Natural GasPhase Gas

Maximum MinimumFlow Rate

Max. Shutoff Differential Pressure 475

HOLDInlet Pressure 475 420

HOLD

Inlet Temperature 101 94

Fluid Density 25.2Fluid Viscosity @ OP. TEMP 0.01

Design Pressure 1360Design Temperature 200

LIN

E Line Size & thicknessIn 2" / SCH 80 TypeOut 2"/ SCH 80 Spring Material Carbon Steel

Mfr & Model Valvitalia LPS-05-135-CM04

Critical Press Pc -

Spring Return, air piston operated.

VALV

E B

OD

Y/B

ON

NET

Type Ball Valve (Reduced Bore) Actuating Medium

Size 2" ASME Class 600 lb Valve Breakaway Torque

Mfr & Model 54 Actuator Break/Run Torque

73 NmMax. Press/Temp 1333 Psi / 248°F Valve Run/Seating Torque 36 / 51 Nm

Inst. AirDouble block & bleed Required Air Failure position Fail Close

245 /84 NmBody/Bonnet Matl ASTM A350 LF2 Maximum Shutoff DP 475 psiLiner Material/ID N/A Process Connection Top/Side Mounting

Fig Face Finish RF, Smooth Finish.ASME B16.5 Mechanical Limit Stop Yes

2", RF, 600 lb On/Off Yes2", RF, 600 lb Speed Control Yes

Not RequiredFlow Direction Bi-directional valve Max. stroke Time 1 Sec for Nominal inch

Spiral Wound SS316L with Graphite Filler

End Ext/Matl Not Applicable Handwheel

1/2" NPT (F)

Type of Bonnet Standard Enclosure Material CS Lub & Iso Valve Yes Local Position Indicator

MAXSEAL IFR3 1/4" NPTBody/Bonnet Gasket

Required

Required (Mechanical)Packing Material PTFE or Equivalent Local Control Cabinet Stainless Steel

Mfr & ModelBolts / Nuts ASTM A193 Gr B7M / A194 Gr 2HM Process Connection

TRIM

Type Ball Filter Reg & Gauge

Characteristic On-Off Valve Supply PressureSize RB Line Filter

62-SOV-6075A and 62-SOV-6075B

Mfr. & ModelBall ASTM A182 F316 Tag NumberRated N/A

Required

Valve OPENStem/Trunnion

Instrument Air Balanced/Unbalanced N/A Regulator Pressure Range 59,5 psi g (4,1 barg)

Relief Valve Set Pressure

ASCO NFET8327B202

Air Accumulator N/A

87 psi g (6 barg)

Seat Ring Material24VDC± 10%

ASTM A182 F316 Solenoid Energised17-4-PH / ASTM A182 F316 Type & Material 3/2 Way/ 316 SS

DEVLON Voltage RatingSealsOther seal VITON AED + GRAPHITE Enclosure Class / Material

Valve Control Panel

- Capacity N/A

- Pressure Switch- Relief Valve

EEx'd'/316 SSConduit Connection SizeManual Reset

Required, SS 316, IP 65 Mfr & Model

Proximity Type, Hermetical Seal, DPDTN/A QuantityN/A Type

Partial Stroking Facility Not Required Contacts Rating 24V DC @ 1AIP 67

Local Reset N.A.Hydraulic Power Pack Not Required Enclosure Class / Material

API 6FAANSI/FCI Leakage Class High Tightness Class VIFire TestTE

STS

Hydrostatic / Pneumatic

AC

TUA

TOR

Pipe Line Insulation

EndRE

GULA

TOR

SOLE

NO

ID V

ALV

E

SPEC

IALS

/ A

CC

ESSO

RIE

S

LIM

IT S

WIT

CH

API 598/API 6D

Page 28: Cover pneumatic valves.pdf · 2013. 9. 10. · API 598/API 6D API 6FA ANSI/FCI Leakage Class High Tightness Class VI Fire Test Local Reset Yes TESTS Hydrostatic / Pneumatic ... Area

123456789

10 Units Normal Shut-Off11 mmscfd HOLD -

12 psig 43013 °F 100 -

14 psi -

15 psig16 °F -

17 Kg/m3 -

18 CP -

19 psi20 6321 6422 6523 6624 6725 6826 6927 7028 7129 7230 In 7331 Out 7432 7533 7634 7735 7836 7937 8038 8139 8240 8341 8442 8543 8644 8745 8846 8947 9048 9149 9250 9351 94 M20 x 1,552 95 Yes (ON PNEUMATIC VALVE)53 9654 9755 98 4 Nos.56 99 WESTLOCK 2649SBYN00042BEI-0057 10058 10159 10260 10361 10462 105

Line NumberA/essel No. NG-006-24"-E41

ZUEITINA OIL COMPANY

Data Sheets for ESD and Blowdown Valves- 103A Area

DOC. NO. 2010-0111

ServiceG

ENER

AL

Shut Down - Start-up Bypass Valve

REV 0 DATE 30/06/2010

Start-Up Bypass Valve for 62-XV-6020

Area Classification CLASS 1, ZONE 1, GAS GROUP 11 A, T3Start-Up Bypass Valve

Tag Number 62-XV-6022PID Number 40227/PR/1/02/102

Function

SER

VIC

E C

ON

DIT

ION

S

Fluid Natural GasPhase Gas

Maximum MinimumFlow Rate

Max. Shutoff Differential Pressure 485

HOLDInlet Pressure 485 420

HOLD

Inlet Temperature 101 95

Fluid Density 25.2Fluid Viscosity @ OP. TEMP 0.01

Design Pressure 1360Design Temperature 200

LIN

E Line Size & thicknessIn 2" / SCH 80 TypeOut 2"/ SCH 80 Spring Material Carbon Steel

Mfr & Model Valvitalia LPS-05-135-CM04

Critical Press Pc -

Spring Return, air piston operated.

VALV

E B

OD

Y/B

ON

NET

Type Ball Valve (Reduced Bore)

Size 2" ASME Class 600 lb

Mfr & Model 54

Liner Material/ID N/A

Fig Face Finish

Actuating Medium Inst. Air Double block & bleed Required Air Failure position Fail Close

Body/Bonnet Matl ASTM A350 LF2 Maximum Shutoff DP 485 psi

Valve Breakaway Torque 73 NmMax. Press/Temp 1333 Psi / 248°F Valve Run/Seating Torque 36 / 51 Nm

Actuator Break/Run Torque 245 /84 Nm

Process Connection Top/Side Mounting2", RF, 600 lb On/Off Yes

Yes

Yes

Handwheel Not Required

Standard

End Ext/Matl

Enclosure Material CS

Not Applicable1 Sec for Nominal inchFlow Direction Bi-directional valve Max. stroke Time

AC

TUA

TOR

Pipe Line Insulation

End

Type of Bonnet

RF, Smooth Finish.ASME B16.5 Mechanical Limit Stop2", RF, 600 lb Speed Control

Yes

Ball ASTM A182 F316Relief Valve Set Pressure

Body/Bonnet Gasket Spiral Wound SS316L with Graphite Filler Mfr & ModelBolts / Nuts ASTM A193 Gr B7M / A194 Gr 2HM

Required (Mechanical)Packing Material PTFE or Equivalent Local Control Cabinet Stainless SteelLub & I so Valve Local Position Indicator

N/A

RequiredInstrument Air

Required

REGU

LATO

R

Line Filter

trim

Type Bali Filter Reg & Gauge

Characteristic On-Off Valve

Mfr. & Model

Seat Ring Material

MAXSEAL IFR3 1/4" NPTProcess Connection

87 psi g (6 barg)

Supply Pressure

1/2 " NPT (F)

ASCO NFET8327B202

Size RB

N/ABalanced/Unbalanced Regulator Pressure Range 59,5 psi g (4,1 barg)

Tag Number 62-SOV-6022A and 62-SOV-6022B

Rated

Stem/Trunnion 17-4-PH / ASTM A182 F316 Type & Material 3/2 Way/316 SS

Enclosure Class / Material

ASTM A182 F316 Solenoid Energised Valve OPEN

- Relief Valve N/A

Conduit Connection SizeManual Reset

- Capacity N/A

SOLE

NO

ID V

ALV

E

Seals DEVLONOther seal VITON AED + GRAPHITE EEx'd'/316 SS

Voltage Rating

Mfr & Model- Pressure Switch N/A Quantity

24VDC ± 10%

Type Proximity Type, Hermetical Seal, DPDT

Local Reset N.A.

24V DC @ 1AHydraulic Power Pack Not Required Enclosure Class / Material IP 67

Not Required Contacts RatingPartial Stroking Facility

ANSI/FCI Leakage Class High Tightness Class VIFire Test API 6FATE

STS

API 598/API 6DHydrostatic / Pneumatic

SPEC

IALS

/ A

CC

ESSO

RIE

S

LIM

IT S

WIT

CH

Valve Control Panel Required, SS 316, IP 65

Air Accumulator N/A

Page 29: Cover pneumatic valves.pdf · 2013. 9. 10. · API 598/API 6D API 6FA ANSI/FCI Leakage Class High Tightness Class VI Fire Test Local Reset Yes TESTS Hydrostatic / Pneumatic ... Area

123456789

10 Units Normal Shut-Off11 mmscfd HOLD -

12 psig 42013 °F 100 -

14 psi -

15 psig16 °F -

17 Kg/m3 -

18 CP -

19 psi20 6321 6422 6523 6624 6725 6826 6927 7028 7129 7230 In 7331 Out 7432 7533 7634 7735 7836 7937 8038 8139 8240 8341 8442 8543 8644 8745 8846 8947 9048 9149 9250 9351 94 M20 x 1,552 95 Yes (ON PNEUMATIC VALVE)53 9654 9755 98 4 Nos. 56 99 WESTLOCK 2649SBYN00042BEI-0057 10058 10159 10260 10361 10462 105

ZUEITINA OIL COMPANY

Data Sheets for ESD and Blowdown Valves- 103A Area

DOC. NO. 2010-0111 REV 0 DATE 30/06/2010

GEN

ERA

LTag Number 62-XV-6101PID Number 40227/PR/1/02/108Service Start-Up Bypass Valve for 62-XV-6100Line NumberA/essel No. NG-101-24"-E41Function Unit Shut Down - Start-up Bypass ValveArea Classification CLASS 1, ZONE 1, GAS GROUP HA, T3Start-Up Bypass ValveFluid Natural Gas

Maximum MinimumPhase Gas

525

HOLDInlet Pressure 475 415Flow Rate

Inlet Temperature 101 92

HOLD

SER

VIC

E C

ON

DIT

ION

S

Design Pressure 1360Design Temperature 200Fluid Density 25.2Fluid Viscosity @ OP. TEMP 0.01

Max. Shutoff Differential Pressure

LIN

E Line Size & thicknessIn 2" 1 SCH 80 TypeOut 2" / SCH 80 Spring Material

Double block & bleed Required Air Failure position

Critical Press Pc -

Spring Return, air piston operated.

54 Actuator Break/Run Torque

Carbon SteelMfr & Model Valvitalia LPS-05-135-CM04

Inst. Air Fail Close

VALV

E B

OD

Y/B

ON

NET

Type Ball Valve (Reduced Bore) Actuating Medium

Size

245 /84 NmBody/Bonnet Matl ASTM A350 LF2 Maximum Shutoff DP

Yes

525 psi

73 NmMax. Press/Temp 1333 Psi / 248°F Valve Run/Seating Torque 36 / 51 Nm

2" ASME Class 600 lb Valve Breakaway Torque

Mfr & Model

Process Connection Top/Side Mounting

2", RF, 600 lb Speed Control Yes

RF, Smooth Finish.ASME B16.5End Ext/Matl Not Applicable

Liner Material/ID N/A

Handwheel Not Required

2", RF, 600 lb On/Off YesAC

TUA

TOR

Pipe Line Insulation

End

Mechanical Limit StopFig Face Finish

MAXSEAL IFR3 1/4" NPT

1 Sec for Nominal inchType of Bonnet Standard Enclosure Material CS

Bi-directional valve Max. stroke TimeFlow Direction

Required

Required (Mechanical)Packing Material PTFE or Equivalent Local Control Cabinet Stainless SteelLub & I so Valve Yes

Bolts / Nuts ASTM A193 Gr B7M / A194 Gr 2HM Process Connection

Local Position Indicator

1/2 " NPT (F)

trim

Type Ball Filter Reg & Gauge

Balanced/UnbalancedRated N/A Relief Valve Set Pressure 87 psi g (6 barg)

Size RB

REGU

LATO

R

Body/Bonnet Gasket Spiral Wound SS316L with Graphite Filler Mfr & Model

RequiredCharacteristic On-Off Valve Supply Pressure Instrument Air

59,5 psi g (4,1 barg)N/A Regulator Pressure Range

Line Filter

3/2 Way/316 SS

62-SOV-6101A and 62-SOV-6101BMfr. & Model ASCO NFET8327B202

Ball ASTM A182 F316 Tag Number

EEx'd*/316 SS

Valve OPENSeals DEVLON Voltage Rating 24VDC ± 10%Seat Ring Material ASTM A182 F316 Solenoid Energised

Required, SS 316, IP 65 Mfr & Model

Other seal VITON AED + GRAPHITE Enclosure Class / MaterialConduit Connection Size

- Capacity- Relief Valve

Air Accumulator N/A Manual ResetSOLE

NO

ID V

ALV

E

Type & Material17-4-PH / ASTM A182 F316Stem/Trunnion

N/AProximity Type, Hermetical Seal, DPDTN/A Type

Contacts Rating 24V DC @ 1AHydraulic Power Pack Not Required Enclosure Class / Material IP 67

N/A QuantityValve Control Panel- Pressure Switch

Local Reset N.A.

Partial Stroking Facility Not Required

TEST

S

Hydrostatic / Pneumatic

Fire Test

SPEC

IALS

/ A

CC

ESSO

RIE

S

LIM

IT S

WIT

CH

API 598/API 6D

API 6FAANSI/FCI Leakage Class High Tightness Class VI

Page 30: Cover pneumatic valves.pdf · 2013. 9. 10. · API 598/API 6D API 6FA ANSI/FCI Leakage Class High Tightness Class VI Fire Test Local Reset Yes TESTS Hydrostatic / Pneumatic ... Area

123456789

10 Units Normal Shut-Off11 mmscfd HOLD -

12 psig 779-132413 °F 130 -

14 psi -

15 psig16 °F -

17 Kg/m3 -

18 CP -

19 psi20 6321 6422 6523 6624 6725 6826 6927 7028 7129 7230 In 7331 Out 7432 7533 7634 7735 7836 7937 8038 8139 8240 8341 8442 8543 8644 8745 8846 8947 9048 9149 9250 9351 94 M20 x 1,552 95 Yes (ON PNEUMATIC VALVE)53 9654 9755 98 4 Nos.56 99 WESTLOCK 2649SBYN00042BEI-0057 10058 10159 10260 10361 10462 105

Line NumberA/essel No. NG-102-20"-F40

ZUEITINA OIL COMPANY

Data Sheets for ESD and Blowdown Valves- 103A Area

DOC. NO. 2010-0111

Servicege

nera

l

Unit Shut Down - Start-up Bypass Valve

REV 0 DATE 30/06/2010

Start-Up Bypass Valve for 62-XV-6102

Area Classification CLASS 1, ZONE 1, GAS GROUP IIA, T3Start-Up Bypass Valve

Tag Number 62-XV-6103PID Number 40227/PR/1/02/108

Function

serv

ice

cond

ition

s

Fluid Natural GasPhase Gas

Maximum MinimumFlow Rate

Max. Shutoff Differential Pressure 1338

HOLDInlet Pressure 1338 775

HOLD

Inlet Temperature 130 125

Fluid Density 44-78.3Fluid Viscosity @ OP. TEMP 0.01 to 0.03

Design Pressure 1480Design Temperature 300

line Line Size & thickness

In 2"/ SCH 80 TypeOut 2" / SCH 80 Spring Material

Valvitalia LPS-05-135-CM04

Critical Press Pc -

Spring Return, air piston operated.Carbon Steel

Pipe Line Insulation Mfr & Model

Liner Material/ID N/A

Inst. AirDouble block & bleed Required Air Failure position Fail Close

2" ASME Class 900 lb Valve Breakaway Torque

ASTM A350 LF2 Maximum Shutoff DP

valv

e bo

dy/b

onne

t

Type Ball Valve (Reduced Bore) Actuating Medium

SizeMax. Press/Temp 1998 Psi / 248 °F Valve Run/Seating Torque

Process Connection

Mfr & Model 54 Actuator Break/Run Torque 245 /84 Nm

Not Applicable

Body/Bonnet Matl

1 Sec for Nominal inch

On/Off Yes

Fig Face Finish

2", RF, 900 lbEnd

End Ext/Matl

Top/Side Mounting

2", RF, 900 lb Speed Control Yes

RF, Smooth Finish.ASME B16.5 Mechanical Limit Stop Yes

Lub & Iso ValveType of Bonnet Standard Enclosure Material

MAXSEAL IFR3 1/4" NPT

AC

TUA

TOR

Required (Mechanical)

1338 psi

84 Nm

Stainless Steel

CS

Handwheel Not Required

42 / 59 Nm

1/2" NPT (F)Required

Flow Direction Bi-directional valve Max. stroke Time

Packing Material PTFE or Equivalent Local Control CabinetYes Local Position Indicator

On-Off Valve Supply Pressure Instrument Air

Body/Bonnet Gasket Spiral Wound SS316L with Graphite Filler Mfr & Model

Line Filter

Bolts / Nuts ASTM A193 Gr B7M / A194 Gr 2HM Process Connection

59,5 psi g (4,1 barg)

62-SOV-6103A and 62-SOV-6103BASCO NFET8327B202

Required

TRIM

Type Ball Filter Reg & Gauge

Characteristic

87 psi g (6 barg)Ball ASTM A182 F316 Tag Number

N/A Relief Valve Set Pressure

Mfr. & Model

REGU

LATO

R

Size RB

SOLE

NO

ID V

ALV

E

Regulator Pressure Range

Enclosure Class / Material

Valve OPENStem/Trunnion

Solenoid EnergisedType & Material

Voltage Rating 24VDC ± 10%EEx'd'/316 SSOther seal

3/2 Way/316 SS

Proximity Type, Hermetical Seal, DPDT- Pressure Switch N/A Quantity- Relief Valve N/A Type

IP 67Partial Stroking Facility Not RequiredHydraulic Power Pack Not Required Enclosure Class / Material

24V DC @ 1A

ANSI/FCI Leakage Class

TEST

S High Tightness Class VI

SPEC

IALS

/ A

CC

ESSO

RIE

S

LIM

IT S

WIT

CH

Air Accumulator N/A

Valve Control Panel Required, SS 316, IP 65

17-4-PH

Local Reset N.A.

Contacts RatingMfr & Model

Conduit Connection SizeManual Reset

VITON AED + GRAPHITE

API 6FA

Hydrostatic / Pneumatic API 598/API 6D

Seals DEVLON

Balanced/Unbalanced

Fire Test

N/A

- Capacity N/A

Seat Ring Material ASTM A182 F316

Rated

Page 31: Cover pneumatic valves.pdf · 2013. 9. 10. · API 598/API 6D API 6FA ANSI/FCI Leakage Class High Tightness Class VI Fire Test Local Reset Yes TESTS Hydrostatic / Pneumatic ... Area

123456789

10 Units Normal Shut-Off11 mmscfd HOLD -

12 psig 42013 °F 100 -

14 psi -

15 psig16 °F -

17 Kg/m3 -

18 CP -

19 psi20 6321 6422 6523 6624 6725 6826 6927 7028 7129 7230 In 7331 Out 7432 7533 7634 7735 7836 7937 8038 8139 8240 8341 8442 8543 8644 8745 8846 8947 9048 9149 9250 9351 94 M20 x 1,552 95 Yes (ON PNEUMATIC VALVE)53 9654 9755 98 4 Nos.56 99 WESTLOCK 2649SBYN00042BEI-0057 10058 10159 10260 10361 10462 105

Line NumberA/essel No. NG-102-24"-E41

ZUEITINA OIL COMPANY

Data Sheets for ESD and Blowdown Valves- 103A Area

DOC. NO. 2010-0111

ServiceG

ENER

AL

Unit Shut Down - Start-up Bypass Valve

REV 0 DATE 30/06/2010

Start-Up Bypass Valve for 62-XV-6200

Area Classification CLASS 1, ZONE 1, GAS GROUP IIA, T3Start-Up Bypass Valve

Tag Number 62-XV-6201PID Number 40227/PR/1/02/109

Function

SER

VIC

E C

ON

DIT

ION

S

Fluid Natural GasPhase Gas

Maximum MinimumFlow Rate

Max. Shutoff Differential Pressure 525

HOLDInlet Pressure 475 415

HOLD

Inlet Temperature 101 92

Fluid Density 25.2Fluid Viscosity @ OP. TEMP 0.01

Design Pressure 1360Design Temperature 200

LIN

E Line Size & thicknessIn 2" 1 SCH 80 TypeOut 2"/ SCH 80 Spring Material

Mfr & Model Valvitalia LPS-05-135-CM04

Critical Press Pc -

Spring Return, air piston operated.Carbon Steel

Pipe Line Insulation

VALV

E B

OD

Y/B

ON

NET

Type Ball Valve (Reduced Bore) Actuating Medium

Size 2" ASME Class 600 lb Valve Breakaway Torque

Mfr & Model 54

Liner Material/ID

73 NmMax. Press/Temp 1333 Psi / 248°F Valve Run/Seating Torque 36 / 51 Nm

Inst. AirDouble block & bleed Required Air Failure position Fail Close

N/A Process Connection

Actuator Break/Run Torque

Top/Side Mounting

245 /84 NmBody/Bonnet Matl ASTM A350 LF2 Maximum Shutoff DP 525 psi

Fig Face Finish RF, Smooth Finish.ASME B16.5 Mechanical Limit Stop Yes

2", RF, 600 lb On/Off Yes2", RF, 600 lb Speed Control Yes

End

Handwheel Not RequiredFlow Direction Bi-directional valve Max. stroke Time 1 Sec for Nominal inchEnd Ext/Matl Not Applicable

AC

TUA

TOR

Stainless Steel

CSLub & iso Valve Yes Local Position Indicator Required (Mechanical)Type of Bonnet Standard Enclosure Material

Packing Material

ASTM A182 F316

Other seal

17-4-PH / ASTM A182 F316

VITON AED + GRAPHITE

Stem/Trunnion

MAXSEAL IFR3 1/4" NPTBolts / Nuts ASTM A193 Gr B7M / A194 Gr 2HM Process Connection 1/2 " NPT (F)

PTFE or Equivalent Local Control Cabinet

Size RB Line FilterFilter Reg & Gauge

Body/Bonnet Gasket Spiral Wound SS316L with Graphite Filler Mfr & Model

N/A

Required

trim

Type Ball

Characteristic On-Off Valve

Rated62-SOV-6201A and 62-SOV-6201B

REGU

LATO

R

Instrument Air (Note 5)Balanced/Unbalanced N/A Regulator Pressure Range 59,5 psi g (4,1 barg)

Supply Pressure

Required

Type & Material 3/2 Way/316 SSMfr. & Model

Relief Valve Set Pressure 87 psi g (6 barg)Ball ASTM A182 F316 Tag Number

Solenoid Energised Valve OPENSeals DEVLON Voltage Rating 24VDC± 10%

SOLE

NO

ID V

ALV

E ASCO NFET8327B202

Seat Ring Material

24V DC @ 1A

Proximity Type, Hermetical Seal, DPDT

Conduit Connection SizeAir Accumulator N/A Manual Reset- Capacity

Enclosure Class / Material EEx'd'/316 SS

- Pressure Switch N/A Quantity- Relief Valve N/A Type

N/A

Valve Control Panel Required, SS 316, IP 65 Mfr & ModelPartial Stroking Facility Not Required Contacts Rating

Local Reset N.A.IP 67Hydraulic Power Pack Not Required Enclosure Class / Material

TEST

S

Hydrostatic / Pneumatic

Fire Test

SPEC

IALS

/ A

CC

ESSO

RIE

S

LIM

IT S

WIT

CH

API 598/API 6D

API 6FAANSI/FCI Leakage Class High Tightness Class VI

Page 32: Cover pneumatic valves.pdf · 2013. 9. 10. · API 598/API 6D API 6FA ANSI/FCI Leakage Class High Tightness Class VI Fire Test Local Reset Yes TESTS Hydrostatic / Pneumatic ... Area

123456789

10 Units Normal Shut-Off11 mmscfd HOLD -

12 psig 779-132413 °F 130 -

14 psi -

15 psig16 °F -

17 Kg/m3 -

18 CP -

19 psi20 21 63

6422 6523 6624 6725 6826 6927 7028 7129 7230 In 7331 Out 7432 7533 7634 7735 7836 7937 8038 8139 8240 8341 8442 8543 8644 8745 8846 8947 9048 9149 9250 9351 94 M20 x 1,552 95 Yes (ON PNEUMATIC VALVE)53 9654 9755 98 4 Nos.56 99 WESTLOCK 2649SBYN00042BEI-0057 10058 10159 10260 10361 10462 105

Line NumberA/essel No. NG-105-20"-F40

ZUEITINA OIL COMPANY

Data Sheets for ESD and Blowdown Valves- 103A Area

DOC. NO. 2010-0111

ServiceG

ENER

AL

REV 0 DATE 30/06/2010

Start-Up Bypass Valve for 62-XV-6202

CLASS 1, ZONE 1, GAS GROUP IIA, T3Start-Up Bypass Valve

Unit Shut Down - Start-up Bypass Valve

Tag Number 62-XV-6203PID Number 40227/PR/1/02/109

Function

HOLD

Natural GasPhase Gas

Maximum MinimumHOLD

Area Classification

Inlet Temperature 130 125Max. Shutoff Differential Pressure 1338

Inlet Pressure 1338 775Flow Rate

0.01 to 0.03Critical Press Pc -

Design Pressure 1480Design Temperature 300

SER

VIC

E C

ON

DIT

ION

S

Fluid

Spring Material Carbon SteelType Spring Return, air piston operated.

Out 2" / SCH 80

Fluid Density 44-78.3Fluid Viscosity @ OP. TEMP

Mfr & Model Valvitalia LPS-05-135-CM04Pipe Line Insulation

LIN

E Line Size & thicknessIn 2"/ SCH 80

VALV

E B

OD

Y/BO

NN

ET

Type Ball Valve (Reduced Bore) Actuating Medium

Size 2" ASME Class 900 lb Valve Breakaway Torque

Mfr & Model 54 Actuator Break/Run Torque

84 NmMax. Press/Temp 1998 Psi / 248°F Valve Run/Seating Torque 42 / 59 Nm

Inst. AirDouble block & bleed Required Air Failure position Fail Close

Liner Material/ID N/A Process Connection Top/Side Mounting

245 /84 NmBody/Bonnet Matl ASTM A350 LF2 Maximum Shutoff DP 1338 psi

Yes

2", RF, 900 lb On/Off Yes2", RF, 900 lb Speed Control Yes

End

End Ext/Matl Not Applicable HandwheelFig Face Finish RF, Smooth Finish.ASME B16.5 Mechanical Limit Stop

Standard Enclosure Material CS

Not RequiredFlow Direction Bi-directional valve Max. stroke Time 1 Sec for Nominal inch

Packing Material PTFE or Equivalent Local Control Cabinet Stainless Steel

AC

TUA

TOR

Lub & I so Valve Yes Local Position Indicator Required (Mechanical)Type of Bonnet

MAXSEAL IFR3 1/4" NPTBolts / Nuts ASTM A193 Gr B7M / A194 Gr 2HM Process Connection 1/2 " NPT (F)Body/Bonnet Gasket Spiral Wound SS316L with Graphite Filler

Required

TRIM

Type Ball Filter Reg & Gauge

Characteristic On-Off Valve Supply Pressure

Rated N/A Relief Valve Set Pressure

Size RB Line Filter

REGU

LATO

R

Mfr & Model

RequiredInstrument Air

Balanced/Unbalanced N/A Regulator Pressure Range 59,5 psi g (4,1 barg)87 psi g (6 barg)

Ball ASTM A182 F316

SOLE

NO

ID V

ALV

E

Tag Number 62-SOV-6203A and 62-SOV-6203B

Mfr. & Model ASCO NFET8327B202

Seat Ring Material ASTM A182 F316 Solenoid Energised Valve OPENStem/Trunnion 17-4-PH Type & Material 3/2 Way/316 SS

EEx'd'/316 SSSeals DEVLON Voltage Rating 24VDC ± 10%Other seal VITON AED + GRAPHITE Enclosure Class / Material

Manual ResetConduit Connection Size

- Relief Valve N/A Type Proximity Type, Hermetical Seal, DPDT- Capacity

Contacts Rating 24V DC @ 1A

QuantityValve Control Panel Required, SS 316, IP 65 Mfr & Model- Pressure Switch N/A

Hydrostatic / Pneumatic

IP 67Local Reset N.A.Hydraulic Power Pack Not Required Enclosure Class / Material

API 598/API 6D

API 6FAANSI/FCI Leakage Class High Tightness Class VIFire TestTE

STS

SPEC

IALS

/ A

CC

ESSO

RIE

S

LIM

IT S

WIT

CH

Partial Stroking Facility Not Required

Air Accumulator N/AN/A

Page 33: Cover pneumatic valves.pdf · 2013. 9. 10. · API 598/API 6D API 6FA ANSI/FCI Leakage Class High Tightness Class VI Fire Test Local Reset Yes TESTS Hydrostatic / Pneumatic ... Area

123456789

10 Units Normal Shut-Off11 mmscfd HOLD -

12 psig 778-132313 °F 126 -

14 psi -

15 psig16 °F -

17 Kg/m3 -

18 CP -

19 psi20 6321 6422 6523 6624 6725 6826 6927 7028 7129 7230 In 7331 Out 7432 7533 7634 7735 7836 7937 8038 8139 8240 8341 8442 8543 8644 8745 8846 8947 9048 9149 9250 9351 94 M20 x 1,552 95 Yes (ON PNEUMATIC VALVE)53 9654 9755 98 4 Nos. 56 99 WESTLOCK 2649SBYN00042BEI-0057 10058 10159 10260 10361 10462 105

Line NumberA/essel No. NG-016-36"-F40

ZUEITINA OIL COMPANY

Data Sheets for ESD and Blowdown Valves- 103A Area

DOC. NO. 2010-0111

ServiceG

ENER

AL

Shut Down - Start-up Bypass Valve

REV 0 DATE 30/06/2010

Start-Up Bypass Valve for 62-XV-6085

Area Classification CLASS 1, ZONE 1, GAS GROUP MA, T3Start-Up Bypass Valve

Tag Number 62-XV-6086PID Number 40227/PR/1/02/116

Function

SER

VIC

E C

ON

DIT

ION

S

Fluid Natural GasPhase Gas

Maximum MinimumFlow Rate

Max. Shutoff Differential Pressure 1338

HOLDInlet Pressure 1338 775

HOLD

Inlet Temperature 130 125

Fluid Density 44-78.3Fluid Viscosity @ OP. TEMP 0.01 to 0.02

Design Pressure 1480Design Temperature 300

LIN

E Line Size & thicknessIn 2" / SCH 80 TypeOut 2" / SCH 80 Spring Material Carbon Steel

Mfr & Model Valvitalia LPS-05-135-CM04

Critical Press Pc -

Spring Return, air piston operated.

VALV

E B

OD

Y/B

ON

NET

Type Ball Valve (Reduced Bore) Actuating Medium

Max. Press/Temp 1998 Psi / 248°F Valve Run/Seating Torque

Body/Bonnet Matl ASTM A350 LF2 Maximum Shutoff DP

Inst. Air Double block & bleed Required Air Failure position Fail CloseSize 2" ASME Class 900 lb Valve Breakaway Torque 84 Nm

1338psiLiner Material/ID N/A Process Connection Top/Side Mounting

42 / 59 NmMfr & Model 54 Actuator Break/Run Torque 245 /84 Nm

Fig Face Finish RF, Smooth Finish.ASME B16.5 Mechanical Limit Stop Yes

2", RF, 900 lb On/Off Yes2", RF, 900 lb Speed Control Yes

Flow Direction Bi-directional valve Max. stroke Time 1 Sec for Nominal inchEnd Ext/Matl Not Applicable Handwheel Not Required

Local Position Indicator Required (Mechanical)Type of Bonnet Standard Enclosure Material

Body/Bonnet Gasket Spiral Wound SS316L with Graphite Filler Mfr & Model MAXSEAL IFR3 1/4" NPTPacking Material PTFE or Equivalent Local Control Cabinet Stainless Steel

AC

TUA

TOR

Pipe Line Insulation

End

CSLub & Iso Valve Yes

TRIM

Type Ball Filter Reg & Gauge

Characteristic On-Off Valve Supply Pressure

Rated N/A Relief Valve Set Pressure

Process ConnectionRequired

Size RB Line Filter Required

87 psi g (6 barg)Balanced/Unbalanced N/A Regulator Pressure Range 59,5 psi g (4,1 barg)

REGU

LATO

R

Instrument Air

1/2" NPT (F)Bolts / Nuts ASTM A193 Gr B7M / A194 Gr 2HM

Ball ASTM A182 F316 Tag NumberASCO NFET8327B202

Stem/Trunnion 17-4-PH Type & Material 3/2 Way/316 SSMfr. & Model

Enclosure Class / Material

- Capacity N/A

Valve OPENSeals DEVLON Voltage Rating 24VDC± 10%Seat Ring Material ASTM A182 F316 Solenoid Energised

SOLE

NO

ID V

ALV

E

62-SOV-6086A and 62-SOV-6086B

Quantity

EEx'd'/316 SSConduit Connection Size

Air Accumulator N/A Manual Reset

Other seal VITON AED + GRAPHITE

Valve Control Panel Required, SS 316, IP 65 Mfr & Model

- Relief Valve N/A Type Proximity Type, Hermetical Seal, DPDT

- Pressure Switch N/A

Partial Stroking Facility Not Required Contacts Rating

Local ResetHydraulic Power Pack Not Required Enclosure Class / Material IP 67

Fire Test

24V DC @ 1A

N.A.

API 6FAANSI/FCI Leakage Class High Tightness Class VI

SPEC

IALS

/ A

CC

ESSO

RIE

S

LIM

IT S

WIT

CH

API 598/API 6DHydrostatic / Pneumatic

TEST

S

Page 34: Cover pneumatic valves.pdf · 2013. 9. 10. · API 598/API 6D API 6FA ANSI/FCI Leakage Class High Tightness Class VI Fire Test Local Reset Yes TESTS Hydrostatic / Pneumatic ... Area

123456789

10 Units Normal Shut-Off11 mmscfd 36.7 -

12 psig 43013 °F 100 -

14 psi -

15 psig16 °F -

17 Kg/m3 -

18 CP -

19 psi20 6321 6422 6523 6624 6725 6826 6927 7028 7129 7230 In 7331 Out 7432 7533 7634 7735 7836 7937 8038 8139 8240 8341 8442 8543 8644 8745 8846 8947 9048 9149 9250 9351 94 M20 x 1,552 95 Yes (ON PNEUMATIC VALVE)53 9654 9755 98 4 Nos.56 99 WESTLOCK 2649SBYN00042BEI-0057 10058 10159 10260 10361 10462 105

Line Number/Vessel No. NG-114-6"-E41

ZUEITINA OIL COMPANY

Data Sheets for ESD and Blowdown Valves- 103A Area

DOC. NO. 2010-0111

ServiceG

ENER

AL

Blow Down Valve

REV 0 DATE 30/06/2010

Inlet Manifold

Area Classification CLASS 1, ZONE 1, GAS GROUP IIA, T3Start-Up Bypass Valve

Tag Number 62-XV-6972PID Number 40227/PR/1/02/009

Function

SER

VIC

E C

ON

DIT

ION

S

Fluid Natural GasPhase Gas

Maximum MinimumFlow Rate

Max. Shutoff Differential Pressure 470

0Inlet Pressure 470 425

36.7

Inlet Temperature 101 97

Fluid Density 25.2Fluid Viscosity @ OP. TEMP 0.01

Design Pressure 1360Design Temperature 200

LIN

E Line Size & thicknessIn 6"/ SCH 80 TypeOut 6"/ SCH 80 Spring Material

Liner Material/ID

Carbon SteelMfr & Model Valvitalia LPS-07-320-CM12

Valve Run/Seating Torque1342 /656 Nm

Inst. AirSize 6" ASME Class 600 lb Air Failure position

Critical Press Pc -

Spring Return, air piston operated.

Pipe Line Insulation

VALV

E B

OD

Y/B

ON

NET

Type Ball Valve (Full Bore) Actuating Medium

Max. Press/Temp 1333 Psi / 248 °F Valve Breakaway Torque

Body/Bonnet Matl ASTM A350 LF2

Fail Open848 Nm

Mfr & Model 55

Yes

421 / 594 Nm

Maximum Shutoff DP 470 psiActuator Break/Run Torque

N/A Process Connection6", RF, 600 lb On/Off

Yes

Fig Face Finish RF, Smooth Finish.ASME B16.5 Mechanical Limit Stop Yes

End AC

TUA

TOR

Stainless Steel

Not Required

Top/Side Mounting

Packing Material PTFE or Equivalent Local Control Cabinet

Enclosure Material

6", RF, 600 lb Speed Control

Flow Direction Bi-directional valve Max. stroke Time 1 Sec for Nominal inchEnd Ext/Matl Not Applicable Handwheel

CSLub & Iso Valve Yes Local Position Indicator Required (Mechanical)

StandardType of Bonnet

Body/Bonnet Gasket Spiral Wound SS316L with Graphite Filler Mfr & Model MAXSEAL IFR3 1/4" NPTBolts / Nuts ASTM A193 Gr B7M / A194 Gr 2HM Process Connection 1/2" NPT (F)

Required

trim

Type Ball Filter Reg & Gauge

Characteristic On-Off Valve Supply Pressure

Rated N/A

Instrument AirBalanced/Unbalanced N/A Regulator Pressure Range 59,5 psi g (4,1 barg)

REGU

LATO

R

RequiredSize FB Line Filter

Relief Valve Set Pressure 87 psi g (6 barg)Ball ASTM A350 LF2 + 0,003" ENP Tag Number 62-SOV-6972A and 62-SOV-6972B

ASCO NFET8327B202Stem/Trunnion 17-4-PH / ASTM A350 LF2 Type & Material 3/2 Way/316 SS

Mfr. & Model

Valve CLOSESeat Ring Material

Other seal VITON AED + GRAPHITE Enclosure Class / Material EEx'd'/316 SSSeals VITON AED Voltage Rating 24VDC± 10%

Manual ResetSOLE

NO

ID V

ALV

E

Partial Stroking Facility Required, Local Contacts RatingValve Control Panel

- Relief Valve Type- Capacity

IP 67

ASTM A350 LF2 + 0,003" ENP Solenoid Energised

N/A Quantity

Conduit Connection Size

Required, SS 316, IP 65 Mfr & Model

Proximity Type, Hermetical Seal, DPDT

TEST

SLI

MIT

SW

ITC

H

ANSI/FCI Leakage ClassHydrostatic / Pneumatic

Enclosure Class / Material

API 598/API 6DHigh Tightness Class VI

24V DC @ 1A

Local Reset N.A.

SPEC

IALS

/ A

CC

ESSO

RIE

S

Hydraulic Power Pack Not Required

N/A

- Pressure Switch

Air Accumulator N/A

N/A

API 6FAFire Test

Page 35: Cover pneumatic valves.pdf · 2013. 9. 10. · API 598/API 6D API 6FA ANSI/FCI Leakage Class High Tightness Class VI Fire Test Local Reset Yes TESTS Hydrostatic / Pneumatic ... Area

123456789

10 Units Normal Shut-Off11 mmscfd 52.7 -

12 psig 42513 °F 100 -

14 psi -

15 psig16 °F -

17 Kg/m3 -

18 CP -

19 psi20 6321 6422 6523 6624 6725 6826 6927 7028 7129 7230 In 7331 Out 7432 7533 7634 7735 7836 7937 8038 8139 8240 8341 8442 8543 8644 8745 8846 8947 9048 9149 9250 9351 94 M20 x 1,552 95 Yes (ON PNEUMATIC VALVE)53 9654 9755 98 4 Nos.56 99 WESTLOCK 2649SBYN00042BEI-0057 10058 10159 10260 10361 10462 105

ZUEITINA OIL COMPANY

Data Sheets for ESD and Blowdown Valves- 103A Area

DOC. NO. 2010-0111 REV 0 DATE 30/06/2010

62-XV-6076PID Number 40227/PR/1/02/107Service Compressor suction Header

GEN

ERA

LTag Number

Area Classification CLASS 1, ZONE 1, GAS GROUP HA, T3Start-Up Bypass Valve

Line NumberA/essel No. NG-117-6"-E41Function Blow Down Valve

SER

VIC

E C

ON

DIT

ION

S

Fluid Natural GasPhase Gas

Maximum MinimumFlow Rate 52.7

Inlet Temperature 101 94Max. Shutoff Differential Pressure 470

0Inlet Pressure 470 420

Fluid Density 25.2Fluid Viscosity @ OP. TEMP 0.01

Design Pressure 1360Design Temperature 200

Critical Press Pc -

LIN

E Line Size & thicknessIn 6" / SCH 80 Type Spring Return, air piston operated.Out 6" / SCH 80 Spring Material Carbon Steel

VALV

E B

OD

Y/B

ON

NET

Type Ball Valve (Full Bore) Actuating Medium

Max. Press/Temp 1333 Psi / 248 °F Valve Breakaway Torque

Body/Bonnet Matl ASTM A350 LF2 Actuator Break/Run Torque

Size 6" ASME Class 600 lb Air Failure position Fail Open848 Nm

Valvitalia LPS-07-320-CM12Mfr & Model

421 / 594 Nm

Inst. Air

1342 /656 NmMfr & Model 55 Valve Run/Seating Torque

Liner Material/ID N/A Process Connection Top/Side MountingMaximum Shutoff DP 470 psi

6", RF, 600 lb On/Off Yes6", RF, 600 lb Speed Control Yes

Fig Face Finish RF, Smooth Finish,ASME B16.5 Mechanical Limit Stop Yes

Local Position Indicator Required (Mechanical)Type of Bonnet Standard Enclosure Material

Not RequiredFlow Direction Bi-directional valve Max. stroke Time 1 Sec for Nominal inchEnd Ext/Matl Not Applicable Handwheel

Packing Material PTFE or Equivalent Local Control Cabinet Stainless Steel

AC

TUA

TOR

Pipe Line Insulation

End

CS Lub & Iso Valve Yes

Body/Bonnet Gasket Spiral Wound SS316L with Graphite Filler Mfr & Model MAXSEAL IFR3 1/4" NPT

trim

Type Ball Filter Reg & Gauge

Characteristic On-Off Valve Supply Pressure

Ball ASTM A182 F316 Tag Number

RequiredSize FB Line Filter Required

REGU

LATO

RBolts / Nuts ASTM A193 Gr B7M / A194 Gr 2HM Process Connection 1/2" NPT (F)

Rated N/A Relief Valve Set Pressure 87 psi g (6 barg)

Instrument AirBalanced/Unbalanced

3/2 Way/316 SS

N/A Regulator Pressure Range 59,5 psi g (4,1 barg)

62-SOV-6076A and 62-SOV-6076BASCO NFET8327B202Mfr. & Model

17-4-PH / ASTM A182 F316 Type & Material

Seals VITON AED Voltage RatingASTM A182 F316 Solenoid Energised

SOLE

NO

ID V

ALV

E

Stem/Trunnion

EEx'd'/316 SSConduit Connection Size

Air Accumulator Manual ResetN/A

Enclosure Class / Material

Seat Ring Material24VDC ± 10%

Other seal VITON AED + GRAPHITE

Valve CLOSE

Valve Control Panel Required, SS 316, IP 65 Mfr & Model- Pressure Switch- Relief Valve N/A Type- Capacity N/A

Proximity Type, Hermetical Seal, DPDT

Not Required Enclosure Class / Material IP 67Partial Stroking Facility Required, Local 24V DC @ 1A

ANSI/FCI Leakage Class

Local ResetAPI 598/API 6DHigh Tightness Class VIAPI 6FAFire Test

N/A Quantity

Contacts RatingHydraulic Power Pack

N.A.

SPEC

IALS

/ A

CC

ESSO

RIE

S

LIM

IT S

WIT

CH

TEST

S

Hydrostatic / Pneumatic

Page 36: Cover pneumatic valves.pdf · 2013. 9. 10. · API 598/API 6D API 6FA ANSI/FCI Leakage Class High Tightness Class VI Fire Test Local Reset Yes TESTS Hydrostatic / Pneumatic ... Area

123456789

10 Units Normal Shut-Off11 mmscfd 13.9 -

12 psig 94513 °F 166 -

14 psi -

15 psig16 °F -

17 Kg/m3 -

18 CP -

19 psi20 6321 6422 6523 6624 6725 6826 6927 7028 7129 7230 In 7331 Out 7432 7533 7634 7735 7836 7937 8038 8139 8240 8341 8442 8543 8644 8745 8846 8947 9048 9149 9250 9351 94 M20 x 1,552 95 Yes (ON PNEUMATIC VALVE)53 9654 9755 98 4 Nos. 56 99 WESTLOCK 2649SBYN00042BEI-0057 10058 10159 10260 10361 10462 105

Line NumberA/essel No. NG-110-2"-F40

ZUEITINA OIL COMPANY

Data Sheets for ESD and Blowdown Valves-103A Area

DOC. NO. 2010-0111

ServiceG

ENER

AL

Blow Down Valve

REV 0 DATE 30/06/2010

Compressor K-10 Outlet to flare

Area Classification CLASS 1, ZONE 1, GAS GROUP IIA, T3Start-Up Bypass Valve

Tag Number 62-XV-6104PID Number 40227/PR/1/02/108

Function

SER

VIC

E C

ON

DIT

ION

S

Fluid Natural GasPhase Gas

Maximum MinimumFlow Rate

Max. Shutoff Differential Pressure 1338

0Inlet Pressure 945 775

13.9

Inlet Temperature 166 125

Fluid Density 44-78.3Fluid Viscosity @ OP. TEMP 0.01 to 0.03

Design Pressure 1480Design Temperature 300

Critical Press Pc -

LIN

E Line Size & thicknessIn 2" / SCH 80 Type Spring Return, air piston operated.Out 2" / SCH 80 Spring Material Carbon Steel

VALV

E B

OD

Y/B

ON

NET

Type Ball Valve (Full Bore) Actuating MediumSize 2" ASME Class 900 lb Air Failure position

Mfr & Model

Mfr & Model Valvitalia LPS-05-200-CM07

Inst. Air Fail Open

Max. Press/Temp 1998 Psi / 248°F Valve Breakaway Torque 151 Nm

Maximum Shutoff DP 1338 psi

Valve Run/Seating Torque 75 / 105 Nm54Body/Bonnet Matl ASTM A350 LF2 Actuator Break/Run Torque 433 /166 Nm

Top/Side Mounting2", RF, 900 lb On/Off Yes

N/A Process Connection

Yes

Fig Face Finish RF, Smooth Finish.ASME B16.5 Mechanical Limit Stop Yes

2", RF, 900 lb Speed Control

Not RequiredFlow Direction Bi-directional valve Max. stroke Time 1 Sec for Nominal inchEnd Ext/Matl Not Applicable Handwheel

CSLub & I so Valve Yes Local Position Indicator Required (Mechanical)Type of Bonnet Standard Enclosure Material

MAXSEAL IFR3 1/4" NPTPacking Material PTFE or Equivalent Local Control Cabinet Stainless Steel

AC

TUA

TOR

Pipe Line Insulation

End

Liner Material/ID

Process ConnectionBody/Bonnet Gasket Spiral Wound SS316L with Graphite Filler Mfr & Model

REGU

LATO

R

Rated N/A

Bolts / Nuts ASTM A193 Gr B7M / A194 Gr 2HM

Relief Valve Set Pressure

1/2 " NPT (F)

trim

Type Ball Filter Reg & Gauge RequiredSize FB Line Filter Required

Instrument Air Balanced/Unbalanced N/A Regulator Pressure Range 59,5 psi g (4,1 barg)Characteristic On-Off Valve Supply Pressure

Mfr. & ModelBall ASTM A182 F316 Tag Number 62-SOV-6104A and 62-SOV-6104B

87 psi g (6 barg)

N/AN/A

Conduit Connection SizeEEx'd'/316 SS

Valve CLOSEDEVLON

ASCO NFET8327B202Stem/Trunnion 17-4-PH / ASTM A182 F316 Type & Material 3/2 Way/316 SS

Voltage Rating 24VDC ± 10%Other seal VITON AED + GRAPHITE Enclosure Class / Material

Seat Ring Material ASTM A182 F316 Solenoid Energised

SOLE

NO

ID V

ALV

E

Air Accumulator Manual Reset

Seals

Mfr & Model

- Relief Valve N/A Type Proximity Type, Hermetical Seal, DPDT- Pressure Switch N/A Quantity

- Capacity

Local Reset Yes

Contacts Rating 24V DC @ 1AHydraulic Power Pack Not Required Enclosure Class / Material IP 67

ANSI/FCI Leakage Class High Tightness Class VIFire Test API 6FATE

STS

API 598/API 6DHydrostatic / Pneumatic

SPEC

IALS

/ A

CC

ESSO

RIE

S

LIM

IT S

WIT

CH

Partial Stroking Facility Not RequiredValve Control Panel Required, SS 316, IP 65

Page 37: Cover pneumatic valves.pdf · 2013. 9. 10. · API 598/API 6D API 6FA ANSI/FCI Leakage Class High Tightness Class VI Fire Test Local Reset Yes TESTS Hydrostatic / Pneumatic ... Area

123456789

10 Units Normal Shut-Off11 mmscfd 13.9 -

12 psig 94513 °F 166 -

14 psi -

15 psig16 °F -

17 Kg/m3 -

18 CP -

19 psi20 6321 6422 6523 6624 6725 6826 6927 7028 7129 7230 In 7331 Out 7432 7533 7634 7735 7836 7937 8038 8139 8240 8341 8442 8543 8644 8745 8846 8947 9048 9149 9250 9351 94 M20 x 1,552 95 Yes (ON PNEUMATIC VALVE)53 9654 9755 9856 99 WESTLOCK 2649SBYN00042BEI-0057 10058 10159 10260 10361 10462 105

GEN

ERA

L

ZUEITINA OIL COMPANY

Data Sheets for ESD and Blowdown Valves- 103A Area

DOC. NO. 2010-0111 REV 0 DATE 30/06/2010

Tag Number

Line NumberA/essel No. NG-111-2"-F40Function Blow Down Valve

62-XV-6204PID Number 40227/PR/1/02/109Service Compressor K-20 Outlet to flare

SER

VIC

E C

ON

DIT

ION

S

Fluid Natural GasPhase Gas

Maximum Minimum

Inlet Pressure 945 775

Area Classification CLASS 1, ZONE 1, GAS GROUP IIA, T3Start-Up Bypass Valve

Flow Rate 13.9 0

166 125Inlet Temperature

LIN

E Line Size & thicknessIn 2" / SCH 80

Max. Shutoff Differential Pressure 1338Design Pressure 1480Design Temperature 300

TypeOut 2" / SCH 80

Fluid Density 44-78.30.01 to 0.03

Critical Press Pc -

Spring Return, air piston operated.

Fluid Viscosity @ OP. TEMP

Spring Material Carbon Steel

2" ASME Class 900 lb Air Failure position

Mfr & Model Valvitalia LPS-05-200-CM07

Mfr & Model 54

Inst. Air Fail Open

Max. Press/Temp 1998 Psi / 248°F Valve Breakaway Torque 151 Nm75 / 105 Nm

VALV

E B

OD

Y/B

ON

NET

Type Ball Valve (Full Bore) Actuating MediumSize

Valve Run/Seating Torque

Maximum Shutoff DP

Max. stroke Time

Lub & I so Valve

Body/Bonnet Matl ASTM A350 LF2 Actuator Break/Run Torque 433 /166 Nm

Yes

On/Off Yes

1338 psiTop/Side Mounting

PTFE or Equivalent

1 Sec for Nominal inch

2", RF, 900 lb Speed Control Yes

RF, Smooth Finish.ASME B16.5

Local Control Cabinet Stainless Steel

Mechanical Limit StopNot Required

Required (Mechanical)

End Ext/Matl Not Applicable Handwheel

CS Type of Bonnet Standard Enclosure MaterialFlow Direction

Yes Local Position Indicator

AC

TUA

TOR

Pipe Line Insulation

Liner Material/ID N/A

End

Packing Material

Fig Face Finish

Process Connection2", RF, 900 lb

MAXSEAL IFR3 1/4" NPTBolts / Nuts ASTM A193 Gr B7M / A194 Gr 2HM Process Connection 1/2" NPT (F)Body/Bonnet Gasket Spiral Wound SS316L with Graphite Filler Mfr & Model

Bi-directional valve

FB Line Filter Required

TRIM

Type Ball

Characteristic On-Off Valve

Stem/Trunnion 17-4-PH / ASTM A182 F316

Supply Pressure Instrument Air Balanced/Unbalanced N/A Regulator Pressure Range 59,5 psi g (4,1 barg)

REGU

LATO

R

Filter Reg & Gauge RequiredSize

87 psi g (6 barg)Ball ASTM A182 F316 Tag Number 62-SOV-6204A and 62-SOV-6204BRated N/A Relief Valve Set Pressure

Mfr. & Model ASCO NFET8327B202

Seals

Type & Material 3/2 Way/316 SSSeat Ring Material Valve CLOSE

Enclosure Class / Material EEx'd'/316 SSDEVLON Voltage Rating 24VDC ± 10%

VITON AED + GRAPHITE

24V DC @ 1ANot Required Contacts Rating

Manual Reset

4 Nos.Required, SS 316, IP 65 Mfr & Model

SOLE

NO

ID V

ALV

E

Proximity Type, Hermetical Seal, DPDT

Quantity

ASTM A182 F316 Solenoid Energised

Conduit Connection Size

N/A TypeN/AN/A

IP 67Local Reset YesHydraulic Power Pack Not Required Enclosure Class / Material

LIM

IT S

WIT

CH

Partial Stroking Facility

TEST

S

API 598/APi 6DANSI/FCI Leakage Class High Tightness Class VIFire Test API 6FA

Hydrostatic / Pneumatic

Other seal

SPEC

IALS

/ A

CC

ESSO

RIE

S

- Pressure Switch N/A- Relief Valve- CapacityAir Accumulator

Valve Control Panel

Page 38: Cover pneumatic valves.pdf · 2013. 9. 10. · API 598/API 6D API 6FA ANSI/FCI Leakage Class High Tightness Class VI Fire Test Local Reset Yes TESTS Hydrostatic / Pneumatic ... Area

123456789

10 Units Normal Shut-Off11 mmscfd HOLD -

12 psig 779-132413 °F 127 -

14 psi -

15 psig16 °F -

17 Kg/m3 -

18 CP -

19 psi20 6321 6422 6523 6624 6725 6826 6927 7028 7129 7230 In 7331 Out 7432 7533 7634 7735 7836 7937 8038 8139 8240 8341 8442 8543 8644 8745 8846 8947 9048 9149 9250 9351 94 M20 x 1,552 95 Yes (ON PNEUMATIC VALVE)53 9654 9755 98 4 Nos.56 99 WESTLOCK 2649SBYN00042BEI-0057 10058 10159 10260 10361 10462 105

Line NumberA/essel No. NG-011-36"-F40

ZUEITINA OIL COMPANY

Data Sheets for ESD and Blowdown Valves- 103A Area

DOC. NO. 2010-0111

ServiceG

ENER

AL

Shut Down - Start-up Bypass Valve

REV 0 DATE 30/06/2010

Start-Up Bypass Valve for 62-XV-6081

Area Classification CLASS 1, ZONE 1, GAS GROUP IIA, T3Start-Up Bypass Valve

Tag Number 62-XV-6089PID Number 40227/PR/1/02/114

Function

SER

VIC

E C

ON

DIT

ION

S

Fluid Natural GasPhase Gas

Maximum MinimumFlow Rate

Max. Shutoff Differential Pressure 1338

HOLDInlet Pressure 1338 775

HOLD

Inlet Temperature 130 125

Fluid Density 44-78.3Fluid Viscosity @ OP. TEMP 0.01 to 0.02

Design Pressure 1480Design Temperature 300

LIN

E. Line Size & thicknessIn 2"/ SCH 80 TypeOut 2" / SCH 80 Spring Material Carbon Steel

Mfr & Model Valvitalia LPS-05-135-CM04

Critical Press Pc -

Spring Return, air piston operated.

VALV

E B

OD

Y/B

ON

NET

Type Ball Valve (Reduced Bore)

Size 2" ASME Class 900 lb

Liner Material/ID N/A

2", RF, 900 lb

Packing Material

Bolts / Nuts

Actuating Medium Inst. Air Double block & bleed Required Air Failure position Fail Close

1338 psi

Valve Breakaway Torque 84 NmMax. Press/Temp 1998 Psi / 248°F Valve Run/Seating Torque 42 / 59 NmMfr & Model 54 Actuator Break/Run Torque

Process ConnectionBody/Bonnet Matl ASTM A350 LF2 Maximum Shutoff DP

Top/Side Mounting2", RF, 900 lb On/Off Yes

Speed Control Yes

Fig Face Finish RF, Smooth Finish.ASME B16.5 Mechanical Limit Stop Yes

End

Pipe Line Insulation

Not RequiredFlow Direction Bi-directional valve Max. stroke Time 1 Sec for Nominal inchEnd Ext/Matl Not Applicable Handwheel

245 /84 Nm

1/2" NPT (F)

CS Lub & Iso Valve Yes Local Position Indicator Required (Mechanical)Type of Bonnet Standard Enclosure Material

AC

TUA

TOR

Stainless SteelBody/Bonnet Gasket Spiral Wound SS316L with Graphite Filler Mfr & Model MAXSEAL IFR3 1/4" NPT

PTFE or Equivalent Local Control Cabinet

Balanced/Unbalanced N/A

ASTM A193 Gr B7M / A194 Gr 2HM Process Connection

Line Filter RequiredInstrument Air

TRIM

Type Ball Filter Reg & Gauge

Rated N/A Relief Valve Set PressureBall ASTM A182 F316 Tag Number 62-SOV-6089A and 62-SOV-6089B

Regulator Pressure Range 59,5 psi g (4,1 barg)Characteristic On-Off Valve RE

GULA

TOR

87 psi g (6 barg)

Supply Pressure

RequiredSize RB

ASCO NFET8327B202Stem/Trunnion 17-4-PH Type & Material 3/2 Way/316 SS

Mfr. & Model

Valve OPENSeals DEVLON Voltage Rating 24VDC ± 10%

ASTM A182 F316 Solenoid EnergisedSeat Ring Material

EEx'd'/316 SSConduit Connection SizeEnclosure Class / Material

Air Accumulator N/A Manual Reset- Capacity N/A

SOLE

NO

ID V

ALV

E

Other seal VITON AED + GRAPHITE

Proximity Type, Hermetical Seal, DPDT

Valve Control Panel Required, SS 316, IP 65 Mfr & ModelQuantity- Pressure Switch N/A

- Relief Valve N/A Type

Partial Stroking Facility Not Required Contacts Rating

Local ResetHydraulic Power Pack Not Required Enclosure Class / Material IP 67

Fire Test

24V DC @ 1A

N.A.

API 6FAANSI/FCI Leakage Class High Tightness Class VI

SPEC

IALS

/ A

CC

ESSO

RIE

S

LIM

IT S

WIT

CH

API 598/API 6DHydrostatic / Pneumatic

TEST

S

Page 39: Cover pneumatic valves.pdf · 2013. 9. 10. · API 598/API 6D API 6FA ANSI/FCI Leakage Class High Tightness Class VI Fire Test Local Reset Yes TESTS Hydrostatic / Pneumatic ... Area

123456789

10 Units Normal Shut-Off11 mmscfd HOLD -

12 psig 74813 °F 55-120 -

14 psi -

15 psig16 °F -

17 Kg/m3 -

18 CP -

19 psi20 6321 6422 6523 6624 6725 6826 6927 7028 7129 7230 In 7331 Out 7432 7533 7634 7735 7836 7937 8038 8139 8240 8341 8442 8543 8644 8745 8846 8947 9048 9149 9250 9351 94 M20 x 1,552 95 Yes (ON PNEUMATIC VALVE)53 9654 9755 98 4 Nos. 56 99 WESTLOCK 2649SBYN00042BEI-00

57 10058 10159 10260 10361 10462 105

ZUEITINA OIL COMPANY

Data Sheets for ESD and Blowdown Valves- PRMS Area

DOC. NO. 2010-0111 REV 0 DATE 30/06/2010

GEN

ERA

L

Tag Number 63-XV-6003PID Number 40227/PR/2/02/101Service Start-Up Bypass Valve for 63-XV-6004Line NumberA/essel No. NG-002-36"-E40Function

Maximum MinimumFlow Rate HOLD HOLD

Shut Down - Start-up Bypass ValveArea Classification CLASS 1, ZONE 1, GAS GROUP HA, T3Start-Up Bypass Valve

Inlet Pressure 1292 748

SER

VIC

E C

ON

DIT

ION

S

Fluid Natural GasPhase Gas

Design Pressure 1360Design Temperature 200

Inlet Temperature 125 55Max. Shutoff Differential Pressure 1292

Carbon Steel

Fluid Density 46.8Fluid Viscosity @ OP. TEMP 0.01 to 0.02

Fail Close73 Nm

Critical Press Pc -

Spring Return, air piston operated.

2" ASME Class 600 lb Valve Breakaway Torque

Inst. AirValvitalia LPS-05-135-CM04

Spring Material

LIN

E Line Size & thicknessIn 2" / SCH 80 TypeOut 2" / SCH 80

Pipe Line Insulation Mfr & Model

Max. Press/Temp 1333 Psi / 248 °F Valve Run/Seating Torque 36 / 51 Nm

VALV

E B

OD

Y/B

ON

NET

Type Ball Valve (Reduced Bore) Actuating MediumDouble block & bleed Required Air Failure positionSize

Fig Face Finish RF, Smooth Finish,ASME B16.5

245 /84 NmASTM A350 LF2 Maximum Shutoff DPBody/Bonnet Matl 1292 psi

2", RF, 600 lb

Mfr & Model 54 Actuator Break/Run Torque

Yes

Liner Material/ID N/A Process Connection Top/Side Mounting

Speed Control YesEnd Conn.

2", RF, 600 lb Yes

Yes (Mechanical)

Handwheel NoFlow Direction Bi-directional valve Max. stroke Time 1 Sec for Nominal inch

On/Off

PTFE or Equivalent

End Ext/Matl Not Applicable

Enclosure Material

Local Control CabinetLub & Iso Valve Yes Local Position Indicator

Mechanical Limit Stop

Stainless SteelBody/Bonnet Gasket Spiral Wound SS316L with Graphite Filler Mfr & Model MAXSEAL IFR3 1/4" NPT

AC

TUA

TOR

Type of Bonnet Standard

Packing Material

CS

Process Connection 1/2" NPT (F)

REGU

LATO

R

YesLine Filter Yes

Relief Valve Set Pressure 87 psi g (6 barg)

Instrument Air59,5 psi g (4,1 barg)

Bolts / Nuts ASTM A193 Gr B7M / A194 Gr 2HM

Size RB

Ball ASTM A182 F316

N/A Regulator Pressure RangeRated N/A

Tag Number 63-SOV-6003A and 63-SOV-6003B

TRIM

Type Ball Filter Reg & Gauge

Characteristic On-Off Valve Supply PressureBalanced/Unbalanced

Mfr. & Model

ASTM A182 F316 Solenoid Energised3/2 Way/316 SS

Seals DEVLON Voltage Rating 24VDC± 10%Seat Ring MaterialStem/Trunnion 17-4-PH / ASTM A182 F316 Type & Material

Valve OPEN

- Relief Valve N/A Type Proximity Type, Hermetical Seal, DPDT

EEx'd*/316 SS

SOLE

NO

ID V

ALV

E

Other seal VITON AED + GRAPHITE Enclosure Class / MaterialConduit Connection Size

ASCO NFET8327B202

SPEC

IALS

/A

CC

ESSO

RIE

S - Capacity N/AAir Accumulator N/A Manual Reset

- Pressure Switch N/A QuantityValve Control Panel Required, SS 316, IP 65 Mfr & ModelPartial Stroking Facility Not Required Contacts Rating

LIM

IT S

WIT

CH

Local Reset N.A.

24V DC @ 1AHydraulic Power Pack Not Required Enclosure Class / Material IP 67

Hydrostatic / Pneumatic

TEST

S

API 598/API 6DANSI/FCI Leakage Class High Tightness Class VIFire Test API 6FA

Page 40: Cover pneumatic valves.pdf · 2013. 9. 10. · API 598/API 6D API 6FA ANSI/FCI Leakage Class High Tightness Class VI Fire Test Local Reset Yes TESTS Hydrostatic / Pneumatic ... Area

123456789

10 Units Normal Shut-Off11 mmscfd HOLD -

12 psig 74713 °F 55-120 -

14 psi -

15 psig16 °F -

17 Kg/m3 -

18 CP -

19 psi20 6321 6422 6523 6624 6725 6826 6927 7028 7129 7230 In 7331 Out 7432 7533 7634 7735 7836 7937 8038 8139 8240 8341 8442 8543 8644 8745 8846 8947 9048 9149 9250 9351 94 M20 x 1,552 95 Yes (ON PNEUMATIC VALVE)53 9654 9755 98 4 Nos.56 99 WESTLOCK 2649SBYN00042BEI-00

57 10058 10159 10260 10361 10462 105

Partial Stroking Facility

ANSI/FCI Leakage Class High Tightness Class VIFire Test API 6FATE

STS

Local ResetAPI 598/API 6D

Hydraulic Power Pack Not Required Enclosure Class / Material IP 67

Hydrostatic / Pneumatic

24V DC @ 1A

Shut Down - Start-up Bypass Valve

HOLD

Carbon SteelValvitalia LPS-05-135-CM04

1292 psi

Inst. Air

Contacts Rating

Area Classification CLASS 1, ZONE 1, GAS GROUP 11 A, T3Start-Up Bypass Valve

ZUEITINA OIL COMPANY

Data Sheets for ESD and Blowdown Valves- PRMS Area

DOC. NO. 2010-0111 REV 0 DATE 30/06/2010

GEN

ERA

L

Tag Number 63-XV-6011PID Number 40227/PR/2/02/110Service Start-Up Bypass Valve for 63-XV-6010Line NumberA/essel No. NG-004-18"-E40Function

SER

VIC

E C

ON

DIT

ION

S

Fluid Natural GasPhase Gas

Maximum MinimumFlow Rate HOLDInlet Pressure 1292 740

Fluid Density 46.8

Inlet Temperature 125 50Max. Shutoff Differential Pressure 1292

Fluid Viscosity @ OP. TEMP 0.01 to 0.02

Design Pressure 1360Design Temperature 200

LIN

E Line Size & thicknessIn 2"/ SCH 80 TypeOut 2" / SCH 80 Spring Material

Mfr & Model

Critical Press Pc -

Spring Return, air piston operated.

Pipe Line Insulation

VALV

E B

OD

Y/B

ON

NET

Type Ball Valve (Reduced Bore) Actuating MediumDouble block & bleed Required Air Failure positionSize 2" ASME Class 600 lb Valve Breakaway Torque

Fail Close73 Nm

Max. Press/Temp 1333 Psi / 248 °F Valve Run/Seating Torque 36 / 51 Nm245 /84 Nm

N/A Process Connection Top/Side MountingMaximum Shutoff DP

End Conn.

Mechanical Limit Stop

Mfr & Model 54

Liner Material/IDBody/Bonnet Matl ASTM A350 LF2

Actuator Break/Run Torque

Yes2", RF, 600 lb Speed Control2", RF, 600 lb On/Off

Enclosure Material1 Sec for Nominal inch

End Ext/Matl Not Applicable Handwheel NoA

CTU

ATO

R

Flow Direction Bi-directional valve Max. stroke Time

Local Position IndicatorPacking Material PTFE or Equivalent Local Control Cabinet

Fig Face Finish RF, Smooth Finish.ASME B16.5

Lub & Iso Valve YesType of Bonnet Standard

1/2 " NPT (F)

CSYes (Mechanical)

Yes

Stainless Steel

Yes

Body/Bonnet Gasket Spiral Wound SS316L with Graphite Filler Mfr & Model

Balanced/Unbalanced N/A Regulator Pressure Range

Bolts / Nuts ASTM A193 Gr B7M / A194 Gr 2HM Process Connection

59,5 psi g (4,1 barg)

Size RB Line FilterCharacteristic On-Off Valve

87 psi g (6 barg)RatedBall ASTM A182 F316 Tag Number

YesYes

Supply Pressure Instrument Air

Valve OPEN

N/A Relief Valve Set Pressure63-SOV-6011A and 63-SOV-6011BASCO NFET8327B2023/2 Way/ 316 SS

Mfr. & Model

REGU

LATO

R

MAXSEAL IFR3 1/4" NPT

ASTM A182 F316

N/A Manual Reset

Seals DEVLON Voltage RatingOther seal

Type

N.A.

Mfr & ModelQuantity

Not Required

SPEC

IALS

/A

CC

ESSO

RIE

S - Capacity N/A

Valve Control Panel

- Relief Valve

Required, SS 316, IP 65

N/A- Pressure Switch N/A

Air Accumulator

TRIM

Type Bali Filter Reg & Gauge

VITON AED + GRAPHITE

Seat Ring Material Solenoid Energised17-4-PH / ASTM A182 F316 Type & MaterialStem/Trunnion

Proximity Type, Hermetical Seal, DPDT

Enclosure Class / MaterialConduit Connection Size

EEx'd'/316 SS

SOLE

NO

ID V

ALV

E

24VDC ± 10%

LIM

IT S

WIT

CH

Page 41: Cover pneumatic valves.pdf · 2013. 9. 10. · API 598/API 6D API 6FA ANSI/FCI Leakage Class High Tightness Class VI Fire Test Local Reset Yes TESTS Hydrostatic / Pneumatic ... Area

123456789

10 Units Normal Shut-Off11 mmscfd HOLD -

12 psig 74713 °F 55-120 -

14 psi -

15 psig16 °F -

17 Kg/m3 -

18 CP -

19 psi20 6321 6422 6523 6624 6725 6826 6927 7028 7129 7230 In 7331 Out 7432 7533 7634 7735 7836 7937 8038 8139 8240 8341 8442 8543 8644 8745 8846 8947 9048 9149 9250 9351 94 M20 x 1,552 95 Yes (ON PNEUMATIC VALVE)53 9654 9755 98 4 Nos. 56 99 WESTLOCK 2649SBYN00042BEI-00

57 10058 10159 10260 10361 10462 105

ANSI/FCI Leakage Class High Tightness Class VIFire Test API 6FA

Hydrostatic / Pneumatic API 598/API 6D

TEST

S

ZUEITINA OIL COMPANY

Data Sheets for ESD and Blowdown Valves- PRMS Area

DOC. NO. 2010-0111 REV 0 DATE 30/06/2010

Service Start-Up Bypass Valve for 63-XV-6020Line NumberA/essel No. NG-005-18"-E40

GEN

ERA

L

Tag Number 63-XV-6021PID Number 40227/PR/2/02/111

Function Shut Down - Start-up Bypass ValveArea Classification CLASS 1, ZONE 1, GAS GROUP HA, T3Start-Up Bypass Valve

SER

VIC

E C

ON

DIT

ION

S

Fluid Natural GasPhase Gas

Maximum MinimumFlow Rate HOLD

Inlet Temperature 125 50Max. Shutoff Differential Pressure 1292

HOLDInlet Pressure 1292 740

Fluid Density 46.8Fluid Viscosity @ OP. TEMP 0.01 to 0.02

Design Pressure 1360Design Temperature 200

Critical Press Pc -

Spring Return, air piston operated.

Pipe Line Insulation

LIN

E Line Size & thicknessIn 2" / SCH 80 TypeOut 2" / SCH 80 Spring Material

Required Air Failure positionSize 2" ASME Class 600 lb

Flow Direction

Carbon SteelMfr & Model Valvitalia LPS-05-135-CM04

36 / 51 Nm

Inst. Air Fail Close

Valve Breakaway Torque 73 Nm

245 /84 Nm

VALV

E B

OD

Y/B

ON

NET

Type Ball Valve (Reduced Bore) Actuating MediumDouble block & bleed

Mfr & Model 54 Actuator Break/Run Torque

Not Applicable Handwheel

1292 psiLiner Material/ID N/A Process Connection Top/Side MountingBody/Bonnet Matl

Yes

Max. Press/Temp 1333 Psi / 248°F Valve Run/Seating Torque

ASTM A350 LF2 Maximum Shutoff DP

Yes2", RF, 600 lb Speed Control Yes

Yes (Mechanical)

End Conn.2", RF, 600 lb On/Off

CS

Fig Face Finish RF, Smooth Finish.ASME B16.5 Mechanical Limit Stop

Bi-directional valve Max. stroke Time

Local Position IndicatorType of Bonnet Standard Enclosure Material

Type Ball Filter Reg & Gauge

MAXSEAL IFR3 1/4" NPTBody/Bonnet Gasket Spiral Wound SS316L with Graphite Filler Mfr & ModelASTM A193 Gr B7M / A194 Gr 2HM Process Connection

Packing Material PTFE or Equivalent Local Control Cabinet Stainless Steel

AC

TUA

TOR

End Ext/Matl No1 Sec for Nominal inch

Lub & Iso Valve Yes

Instrument AirBalanced/Unbalanced

Size RB Line Filter

87 psi g (6 barg)

REGU

LATO

R

1/2" NPT (F)Bolts / Nuts

N/A Regulator Pressure Range 59,5 psi g (4,1 barg)Rated N/A Relief Valve Set Pressure

TRIM

YesYes

Characteristic On-Off Valve Supply Pressure

Ball ASTM A182 F316 Tag Number 63-SOV-6021A and 63-SOV-6021BMfr. & Model

Stem/Trunnion 17-4-PH / ASTM A182 F316 Type & Material

- Pressure Switch N/A

Seals DEVLON

Conduit Connection Size

ASCO NFET8327B2023/2 Way/316 SS

Seat Ring Material ASTM A182 F316 Solenoid Energised Valve OPENVoltage Rating

SPEC

IALS

/A

CC

ESSO

RIE

S

Air Accumulator N/A Manual Reset- Capacity N/A

Quantity

SOLE

NO

ID V

ALV

E

- Relief Valve

24VDC± 10%Other seal VITON AED + GRAPHITE Enclosure Class / Material EEx'd'/316 SS

Local Reset N.A.

Proximity Type, Hermetical Seal, DPDT

Not Required Contacts Rating 24V DC @ 1A

N/A Type

LIM

IT S

WIT

CH

Hydraulic Power Pack Not Required Enclosure Class / Material IP 67Partial Stroking FacilityValve Control Panel Required, SS 316, IP 65 Mfr & Model

Page 42: Cover pneumatic valves.pdf · 2013. 9. 10. · API 598/API 6D API 6FA ANSI/FCI Leakage Class High Tightness Class VI Fire Test Local Reset Yes TESTS Hydrostatic / Pneumatic ... Area

123456789

10 Units Normal Shut-Off11 mmscfd HOLD -

12 psig 72813 °F 60-95 -

14 psi -

15 psig16 °F -

17 Kg/m3 -

18 CP -

19 psi20 6321 6422 6523 6624 6725 6826 6927 7028 7129 7230 In 7331 Out 7432 7533 7634 7735 7836 7937 8038 8139 8240 8341 8442 8543 8644 8745 8846 8947 9048 9149 9250 9351 94 M20 x 1,552 95 Yes (ON PNEUMATIC VALVE)53 9654 9755 98 4 Nos. 56 99 WESTLOCK 2649SBYN00042BEI-00

57 10058 10159 10260 10361 10462 105

DATE 30/06/2010

SOLE

NO

ID V

ALV

E

DOC. NO. 2010-0111 REV 0

GEN

ERA

L

Tag Number 63-XV-6304PID Number

Function Shut Down - Start-up Bypass ValveArea Classification CLASS 1, ZONE 1, GAS GROUP IIA, T3

40227/PR/2/02/125Service Start-Up Bypass Valve for 63-XV-6304Line NumberA/essel No. NG-026-36"-E40

Start-Up Bypass Valve

SER

VIC

E C

ON

DIT

ION

S

Fluid Natural GasPhase Gas

Maximum Minimum

Inlet Temperature 125 55Max. Shutoff Differential Pressure 1292

Flow Rate HOLD HOLDInlet Pressure 1292 720

Fluid Density 46.8Fluid Viscosity @ OP. TEMP 0.01 to 0.02

Design Pressure 1360Design Temperature 200

LIN

E Line Size & thicknessIn 2" / SCH 80 TypeOut 2" / SCH 80 Spring Material

Size 2" ASME Class 600 lb Valve Breakaway Torque

Critical Press Pc -

Spring Return, air piston operated.Carbon Steel

Mfr & Model Valvitalia LPS-05-135-CM04

Inst. Air Fail CloseAir Failure position73 Nm

Actuator Break/Run TorqueBody/Bonnet Matl ASTM A350 LF2 Maximum Shutoff DP 1292 psi

1333 Psi / 248°F Valve Run/Seating Torque 36 / 51 NmMfr & Model

VALV

E B

OD

Y/B

ON

NET

Type Ball Valve (Reduced Bore) Actuating MediumDouble block & bleed Required

Fig Face Finish

Liner Material/ID N/A

Max. Press/Temp54

Process ConnectionYesTop/Side Mounting

Yes

245 /84 Nm

End Ext/Matl Not Applicable Handwheel

End Conn.2", RF, 600 lb2", RF, 600 lb On/Off

Speed ControlYes

NoRF, Smooth Finish.ASME B16.5 Mechanical Limit Stop

1/2" NPT (F)Spiral Wound SS316L with Graphite Filler

Flow Direction Bi-directional valve Max. stroke Time

Local Control CabinetPTFE or EquivalentPacking MaterialBody/Bonnet Gasket MAXSEAL IFR3 1/4" NPT

1 Sec for Nominal inchType of Bonnet StandardLub & I so Valve Yes

Mfr & Model

ASTM A182 F316

Seat Ring Material ASTM A182 F316 Solenoid Energised

On-Off Valve

Ball

Bolts / Nuts ASTM A193 Gr B7M / A194 Gr 2HM Process ConnectionYes

Size RB Line Filter Yes

TRIM

Type Ball Filter Reg & Gauge

Characteristic Supply Pressure

Seals DEVLON

Instrument Air

Rated N/A Relief Valve Set Pressure 87 psi g (6 barg)

REGU

LATO

R

Balanced/Unbalanced N/A Regulator Pressure Range 59,5 psi g (4,1 barg)

Valve OPENStem/Trunnion 17-4-PH / ASTM A182 F316

63-SOV-6304A and 63-SOV-6304BASCO NFET8327B2023/2 Way/316 SS

Tag NumberMfr. & ModelType & Material

Voltage Rating 24VDC ± 10%Other seal VITON AED + GRAPHITE Enclosure Class / Material EEx'd'/316 SS

Conduit Connection SizeManual Reset

- Capacity N/A

- Pressure Switch

SPEC

IALS

/A

CC

ESSO

RIE

S

Air Accumulator N/A

Proximity Type, Hermetical Seal, DPDT

Partial Stroking Facility Not Required Contacts Rating 24V DC @ 1A

- Relief Valve N/A

LIM

IT S

WIT

CH

IP 67

TypeN/A Quantity

Mfr & Model

Local Reset N.A.

Required, SS 316, IP 65Valve Control Panel

Hydraulic Power Pack Not Required Enclosure Class / Material

Hydrostatic / PneumaticANSI/FCI Leakage Class

TEST

S

API 598/API 6DHigh Tightness Class VI

Fire Test API 6FA

ZUEITINA OIL COMPANY

Data Sheets for ESD and Blowdown Valves- PRMS Area

Pipe Line Insulation

AC

TUA

TOR

CSYes (Mechanical)Stainless Steel

Enclosure MaterialLocal Position Indicator

Page 43: Cover pneumatic valves.pdf · 2013. 9. 10. · API 598/API 6D API 6FA ANSI/FCI Leakage Class High Tightness Class VI Fire Test Local Reset Yes TESTS Hydrostatic / Pneumatic ... Area

123456789

10 Units Normal Shut-Off11 mmscfd HOLD -

12 psig 72813 °F 95 -

14 psi -

15 psig16 °F -

17 Kg/m3 -

18 CP -

19 psi20 6321 6422 6523 6624 6725 6826 6927 7028 7129 7230 In 7331 Out 7432 7533 7634 7735 7836 7937 8038 8139 8240 8341 8442 8543 8644 8745 8846 8947 9048 9149 9250 9351 94 M20 x 1,552 95 Yes (ON PNEUMATIC VALVE)53 9654 9755 98 4 Nos.56 99 WESTLOCK 2649SBYN00042BEI-00

57 10058 10159 10260 10361 10462 105

IP 67Local Reset

API 6FA

N.A.

Fire TestTEST

S ANSI/FCI Leakage Class High Tightness Class VIHydrostatic / Pneumatic API 598/API 6D

24V DC @ 1AValve Control Panel Required, SS 316, IP 65 Mfr & Model

Not Required Contacts RatingPartial Stroking Facility

ZUEITINA OIL COMPANY

Data Sheets for ESD and Blowdown Valves- PRMS Area

DOC. NO. 2010-0111 REV 0 DATE 30/06/2010

GEN

ERA

L

Tag Number 63-XV-6226PID Number 40227/PR/2/02/140Service Start-Up Bypass Valve for 63-XV-6225Line NumberA/essel No. NG-036-18"-E40Function Shut Down - Start-up Bypass ValveArea Classification CLASS 1, ZONE 1, GAS GROUP IIA, T3Start-Up Bypass ValveFluid Natural GasPhase Gas

Maximum Minimum

Max. Shutoff Differential Pressure 1292

Flow Rate HOLD HOLD

Design Pressure 1360

Inlet Pressure 1292 720Inlet Temperature 125 90

Fluid Viscosity @ OP. TEMP 0.01 to 0.02Critical Press Pc -

Design Temperature 200Fluid Density 31

Spring Return, air piston operated.Out 2" / SCH 80 Spring Material

SER

VIC

E C

ON

DIT

ION

S

Carbon Steel

LIN

E Line Size & thicknessIn 2"/ SCH 80 Type

Mfr & Model Valvitalia LPS-05-135-CM04

Type Ball Valve (Reduced Bore) Actuating Medium Inst. Air Pipe Line Insulation

Fail CloseValve Breakaway Torque 73 Nm

VALV

E B

OD

Y/B

ON

NET

Double block & bleed RequiredSize 2" ASME Class 600 lbMax. Press/Temp 1333 Psi / 248°F

Body/Bonnet Matl ASTM A350 LF2 Maximum Shutoff DP 1292 psi

36 / 51 Nm54 Actuator Break/Run Torque 245 /84 Nm

Valve Run/Seating Torque

Yes

Top/Side MountingLiner Material/ID N/A Process ConnectionYes

Air Failure position

Mfr & Model

Fig Face Finish RF, Smooth Finish.ASME B16.5 Mechanical Limit Stop

End Conn.2", RF, 600 lb On/Off2", RF, 600 lb Speed Control

Yes

End Ext/Matl Not Applicable Handwheel No

Yes (Mechanical)

Flow Direction Bi-directional valve Max. stroke TimeType of Bonnet

Mfr & Model MAXSEAL IFR3 1/4" NPT

CS Lub & Iso Valve

Enclosure Material

Packing Material PTFE or Equivalent Local Control CabinetYes Local Position Indicator

Stainless Steel

ASTM A193 Gr B7M / A194 Gr 2HM

YesSupply Pressure Instrument Air

Process Connection 1/2 " NPT (F)

AC

TUA

TOR

1 Sec for Nominal inchStandard

TRIM

Type Ball Filter Reg & GaugeSize RB Line Filter

Rated

On-Off Valve

Stem/Trunnion

87 psi g (6 barg)

REGU

LATO

R

Balanced/Unbalanced N/A Regulator Pressure Range 59,5 psi g (4,1 barg)

Yes

Characteristic

Body/Bonnet Gasket Spiral Wound SS316L with Graphite FillerBolts / Nuts

Mfr. & Model17-4-PH / ASTM A182 F316 Type & Material

N/A Relief Valve Set Pressure63-SOV-6226A and 63-SOV-6226BASCO NFET8327B2023/2 Way/316 SS

Seat Ring Material ASTM A182 F316 Solenoid Energised Valve OPEN

Ball ASTM A182 F316 Tag Number

Hydraulic Power Pack

- Pressure Switch N/A Quantity

Not Required

DEVLON Voltage RatingOther seal VITON AED + GRAPHITE Enclosure Class / Material

SPEC

IALS

/A

CC

ESSO

RIE

S

Air Accumulator N/A Manual Reset- Capacity N/A

Conduit Connection Size

Enclosure Class / Material

- Relief Valve N/A Type Proximity Type, Hermetical Seal, DPDT

SOLE

NO

ID V

ALV

E

24VDC± 10%EEx'd'/316 SS

Seals

LIM

IT S

WIT

CH

Page 44: Cover pneumatic valves.pdf · 2013. 9. 10. · API 598/API 6D API 6FA ANSI/FCI Leakage Class High Tightness Class VI Fire Test Local Reset Yes TESTS Hydrostatic / Pneumatic ... Area

123456789

10 Units Normal Shut-Off11 mmscfd HOLD -

12 psig 50013 °F 40-80 -

14 psi -

15 psig16 °F -

17 Kg/m3 -

18 CP -

19 psi20 6321 6422 6523 6624 6725 6826 6927 7028 7129 7230 In 7331 Out 7432 7533 7634 7735 7836 7937 8038 8139 8240 8341 8442 8543 8644 8745 8846 8947 9048 9149 9250 9351 94 M20 x 1,552 95 Yes (ON PNEUMATIC VALVE)53 9654 9755 98 4 Nos. 56 99 WESTLOCK 2649SBYN00042BEI-00

57 10058 10159 10260 10361 10462 105 Fire Test API 6FA

ANSI/FCI Leakage Class High Tightness Class VI

TEST

S

Hydrostatic / Pneumatic API 598/API 6D

Hydraulic Power Pack Not Required Enclosure Class / Material IP 67Local Reset N.A.

Mfr & Model

Service Start-Up Bypass Valve for 63-XV-6602Line NumberA/essel No. NG-031-36"-E40

Shut Down - Start-up Bypass ValveArea Classification CLASS 1, ZONE 1, GAS GROUP IIA, T3Start-Up Bypass Valve

Partial Stroking Facility Not Required Contacts Rating 24V DC @ 1A

ZUEITINA OIL COMPANY

Data Sheets for ESD and Blowdown Valves- PRMS Area

DOC. NO. 2010-0111 REV 0 DATE 30/06/2010

GEN

ERA

L

Tag Number 63-XV-6603PID Number 40227/PR/2/02/150

FunctionSE

RVI

CE

CO

ND

ITIO

NS

Fluid Natural GasPhase Gas

Maximum MinimumFlow Rate HOLD

Inlet Temperature 100 35Max. Shutoff Differential Pressure 847

HOLDInlet Pressure 770 500

Fluid Density 31Fluid Viscosity @ OP. TEMP 0.01 to 0.02

Design Pressure 1360Design Temperature 200

LIN

E Line Size & thicknessIn 2"/ SCH 80 Type

Valvitalia LPS-05-135-CM04

Critical Press Pc -

Inst. Air

Spring Return, air piston operated.Out 2" / SCH 80 Spring Material Carbon Steel

Pipe Line Insulation

Max. Press/Temp 1333 Psi / 248°F Valve Run/Seating Torque

Mfr & Model

End Conn.

Body/Bonnet Matl

Fail Close73 Nm36 / 51 Nm

Valve Breakaway Torque

Speed Control

End Ext/Matl

Required Air Failure positionSize

Maximum Shutoff DPLiner Material/ID N/A Process Connection

847 psi245 /84 Nm

VALV

E B

OD

Y/B

ON

NET

Type Ball Valve (Reduced Bore) Actuating MediumDouble block & bleed

Mfr & Model

2", RF, 600 lb

2" ASME Class 600 lb

No

54 Actuator Break/Run Torque

Yes

Yes

2", RF, 600 lb On/Off

ASTM A350 LF2Top/Side MountingYes

Fig Face Finish RF, Smooth Finish.ASME B16.5 Mechanical Limit Stop

Type of Bonnet Standard Enclosure Material

Not Applicable HandwheelFlow Direction Bi-directional valve Max. stroke Time 1 Sec for Nominal inch

Lub & Iso Valve Yes Local Position Indicator Yes (Mechanical)

AC

TUA

TOR

Packing Material PTFE or Equivalent Local Control Cabinet Stainless Steel

CS

Process Connection 1/2" NPT (F)Body/Bonnet Gasket Spiral Wound SS316L with Graphite Filler Mfr & Model MAXSEAL IFR3 1/4" NPT

Characteristic

Ball

Bolts / Nuts ASTM A193 Gr B7M / A194 Gr 2HM

Rated N/AASTM A182 F316

Instrument Air Line Filter

TRIM

Type Ball Filter Reg & GaugeSize RB

On-Off Valve

Seat Ring Material

Relief Valve Set Pressure 87 psi g (6 barg)

REGU

LATO

R

Balanced/Unbalanced N/A Regulator Pressure Range 59,5 psi g (4,1 barg)

YesYes

Supply Pressure

Stem/Trunnion 17-4-PH / ASTM A182 F316

24VDC± 10%

Tag NumberMfr. & Model

Seals DEVLON Voltage RatingASTM A182 F316 Solenoid Energised

Enclosure Class / Material

63-SOV-6603A and 63-SOV-6603B

Type & Material

SPEC

IALS

/A

CC

ESSO

RIE

S

Conduit Connection SizeAir Accumulator

- Relief ValveQuantity

Valve Control Panel Required, SS 316, IP 65

N/AProximity Type, Hermetical Seal, DPDT

SOLE

NO

ID V

ALV

E ASCO NFET8327B2023/2 Way/316 SSValve OPEN

Manual Reset

Type

LIM

IT S

WIT

CH

EEx'd'/316 SSOther seal VITON AED + GRAPHITE

- Pressure Switch N/AN/A

- CapacityN/A

Page 45: Cover pneumatic valves.pdf · 2013. 9. 10. · API 598/API 6D API 6FA ANSI/FCI Leakage Class High Tightness Class VI Fire Test Local Reset Yes TESTS Hydrostatic / Pneumatic ... Area

123456789

10 Units Normal Shut-Off11 mmscfd HOLD -

12 psig 50013 °F 40-80 -

14 psi -

15 psig16 °F -

17 Kg/m3 -

18 CP -

19 psi20 6321 6422 6523 6624 6725 6826 6927 7028 7129 7230 In 7331 Out 7432 7533 7634 7735 7836 7937 8038 8139 8240 8341 8442 8543 8644 8745 8846 8947 9048 9149 9250 9351 94 M20 x 1,552 95 Yes (ON PNEUMATIC VALVE)53 9654 9755 98 4 Nos. 56 99 WESTLOCK 2649SBYN00042BEI-00

57 10058 10159 10260 10361 10462 105 Fire TestTE

STS

API 598/API 6DANSI/FCI Leakage Class High Tightness Class VIHydrostatic / Pneumatic

0

API 6FA

40227/PR/2/02/150

Service Start-Up Bypass Valve for 63-XV-6604Line NumberA/essel No. NG-039-20"-E40

Natural GasPhase Gas

DATE 30/06/2010

Minimum

Function Shut Down - Start-up Bypass ValveArea Classification CLASS 1, ZONE 1, GAS GROUP IIA, T3

Maximum

DOC. NO. 2010-0111 REV

GEN

ERA

L

Tag Number 63-XV-6605PID Number

500

Start-Up Bypass Valve

SER

VIC

E C

ON

DIT

ION

S

Fluid

Inlet Temperature 100 35Max. Shutoff Differential Pressure 847

Flow Rate HOLD HOLDInlet Pressure 770

Fluid Density 31Fluid Viscosity @ OP. TEMP 0.01 to 0.02

Design Pressure 1360Design Temperature 200

LIN

E Line Size & thicknessIn 2" / SCH 80 TypeOut 2" / SCH 80 Spring Material

Maximum Shutoff DP

Critical Press Pc -

Spring Return, air piston operated.

36 / 51 NmValve Breakaway Torque

Carbon SteelMfr & Model Valvitalia LPS-05-135-CM04

Mfr & Model

VALV

E B

OD

Y/B

ON

NET

Type Ball Valve (Reduced Bore) Actuating MediumDouble block & bleed Required Air Failure positionSize 2" ASME Class 600 lb

On/Off

Inst. Air Fail Close73 Nm

Max. Press/Temp 1333 Psi / 248°F Valve Run/Seating Torque

Yes2", RF, 600 lb Speed Control Yes

N/A Process Connection

End Ext/Matl Not Applicable Handwheel NoFig Face Finish RF, Smooth Finish.ASME B16.5 Mechanical Limit Stop Yes

245 /84 Nm847 psiTop/Side Mounting

End Conn.2", RF, 600 lb

54 Actuator Break/Run TorqueBody/Bonnet Matl ASTM A350 LF2Liner Material/ID

Bi-directional valve Max. stroke Time

MAXSEAL IFR3 1/4" NPT

Type of Bonnet Standard Enclosure MaterialLub & I so Valve Yes

Stainless Steel

Rated N/ABall

1 Sec for Nominal inch

1/2" NPT (F)Body/Bonnet Gasket

Local Position Indicator

Spiral Wound SS316L with Graphite Filler Mfr & Model

Flow Direction

N/A Regulator Pressure RangeBalanced/Unbalanced

TRIM

Type Ball Filter Reg & GaugeSize RB Line FilterCharacteristic

Bolts / Nuts ASTM A193 Gr B7M / A194 Gr 2HM Process Connection

On-Off Valve

63-SOV-6605A and 63-SOV-6605BRelief Valve Set Pressure 87 psi g (6 barg)

REGU

LATO

R

YesYesInstrument Air59,5 psi g (4,1 barg)

Supply Pressure

Seat Ring MaterialSeals

ASTM A182 F316 Tag NumberMfr. & Model

Stem/TrunnionASCO NFET8327B202

VITON AED + GRAPHITE Enclosure Class / Material EEx'd'/316 SS

17-4-PH / ASTM A182 F316 Type & MaterialASTM A182 F316 Solenoid Energised

DEVLON Voltage Rating

SPEC

IALS

/A

CC

ESSO

RIE

S

Conduit Connection SizeAir Accumulator N/A Manual Reset- Capacity N/A- Relief Valve N/A Type Proximity Type, Hermetical Seal, DPDT

SOLE

NO

ID V

ALV

E

3/2 Way/316 SSValve OPEN24VDC± 10%

Other seal

Not Required Contacts Rating 24V DC @ 1A

- Pressure Switch N/A QuantityValve Control Panel Required, SS 316, IP 65 Mfr & Model

Local Reset N.A.

LIM

IT S

WIT

CH

Hydraulic Power Pack Not Required Enclosure Class / Material IP 67Partial Stroking Facility

ZUEITINA OIL COMPANY

Data Sheets for ESD and Blowdown Valves- PRMS Area

Pipe Line Insulation

AC

TUA

TOR

CS Yes (Mechanical)

Packing Material PTFE or Equivalent Local Control Cabinet

Page 46: Cover pneumatic valves.pdf · 2013. 9. 10. · API 598/API 6D API 6FA ANSI/FCI Leakage Class High Tightness Class VI Fire Test Local Reset Yes TESTS Hydrostatic / Pneumatic ... Area

123456789

10 Units Normal Shut-Off11 mmscfd 34.4 -

12 psig 50013 °F 40-80 -

14 psi -

15 psig16 °F -

17 Kg/m3 -

18 CP -

19 psi20 6321 6422 6523 6624 6725 6826 6927 7028 7129 7230 In 7331 Out 7432 7533 7634 7735 7836 7937 8038 8139 8240 8341 8442 8543 8644 8745 8846 8947 9048 9149 9250 9351 94 M20 x 1,552 95 Yes (ON PNEUMATIC VALVE)53 9654 9755 98 4 Nos. 56 99 WESTLOCK 2649SBYN00042BEI-00

57 ##58 ##59 ##60 ##61 ##62 ##

Hydrostatic / Pneumatic

Fire Test API 6FAANSI/FCI Leakage Class High Tightness Class VI

TEST

S

Service

FunctionArea ClassificationStart-Up Bypass Valve

API 598/API 6D

0

Valvitalia LPS-07-280-CM12

Blow Down ValveCLASS 1, ZONE 1, GAS GROUP HA, T3

63-XV-6600PID Number 40227/PR/2/02/150

Line NumberA/essel No. NG-050-4"-E40

Tag Number

ZUEITINA OIL COMPANY

Data Sheets for ESD and Blowdown Valves- PRMS Area

Tripoli Branch

DOC. NO. 2010-0111 REV DATE 30/06/2010

GEN

ERA

L

0

SER

VIC

E C

ON

DIT

ION

S

Fluid Natural GasPhase Gas

Maximum MinimumFlow Rate

Inlet Temperature 100 35Max. Shutoff Differential Pressure 770

34.4Inlet Pressure 770 500

Fluid Density 31Fluid Viscosity @ OP. TEMP 0.01 to 0.02

Design Pressure 1360Design Temperature 200

LIN

E Line Size & thicknessIn 4" / SCH 80 TypeOut 4" / SCH 80 Spring Material

Pipe Line Insulation Mfr & Model

VALV

E B

OD

Y/B

ON

NET

Type Ball Valve (Full Bore)Size 4" ASME Class 600 lbMax. Press/Temp 1333 Psi / 248°F

Body/Bonnet Matl ASTM A350 LF2

End Conn.

Critical Press Pc -

Spring Return, air piston operated.Carbon Steel

Actuator Break/Run Torque 1342 /626 Nm

Inst. Air Air Failure position Fail OpenValve Breakaway Torque

Actuating Medium

Mfr & Model 54545 Nm

Valve Run/Seating Torque 273 / 382 Nm

On/Off4", RF, 600 lb Speed Control

770 psi

4", RF, 600 lbTop/Side MountingYesYes

Liner Material/ID N/A Process ConnectionMaximum Shutoff DP

Flow DirectionType of Bonnet Standard

1 Sec for Nominal inch

Fig Face Finish RF, Smooth Finish.ASME B16.5 Mechanical Limit Stop Yes

Stainless Steel

Not Applicable Handwheel

Enclosure MaterialYes (Mechanical)

No

CSLub & Iso Valve Yes Local Position Indicator

AC

TUA

TOR

End Ext/Matl

Packing Material PTFE or Equivalent Local Control Cabinet

Bi-directional valve Max. stroke Time

Body/Bonnet Gasket Spiral Wound SS316L with Graphite Filler

REGU

LATO

R

Mfr & ModelBolts / Nuts ASTM A193 Gr B7M / A194 Gr 2HM Process ConnectionType Ball Filter Reg & Gauge

MAXSEAL IFR3 1/4" NPT1/2 M NPT (F)

TRIM

YesSize FB Line Filter YesCharacteristic On-Off Valve

Rated N/A Relief Valve Set Pressure 87 psi g (6 barg)

Supply Pressure Instrument AirBalanced/Unbalanced N/A Regulator Pressure Range 59,5 psi g (4,1 barg)

Stem/Trunnion

Ball ASTM A182 F316 Tag NumberMfr. & Model

63-SOV-6600A and 63-SOV-6600B

Conduit Connection SizeManual Reset

17-4-PH / ASTM A182 F316 Type & MaterialSolenoid Energised

Seals DEVLON Voltage RatingSeat Ring Material ASTM A182 F316

N/A

Other seal VITON AED + GRAPHITE24VDC±10%

Enclosure Class / Material EEx'd'/316 SS

SOLE

NO

ID V

ALV

E ASCO NFET8327B2023/2 Way/316 SSValve CLOSE

SPEC

IALS

/A

CC

ESSO

RIE

S

Air Accumulator N/A- Capacity N/A

- Pressure Switch N/A- Relief Valve

LIM

IT S

WIT

CH

Type Proximity Type, Hermetical Seal, DPDT

QuantityMfr & ModelContacts Rating

Valve Control Panel

Enclosure Class / Material IP 67Hydraulic Power Pack Not Required

Required, SS 316, IP 65Partial Stroking Facility Not Required 24V DC @ 1A

Local Reset N.A.

Page 47: Cover pneumatic valves.pdf · 2013. 9. 10. · API 598/API 6D API 6FA ANSI/FCI Leakage Class High Tightness Class VI Fire Test Local Reset Yes TESTS Hydrostatic / Pneumatic ... Area

123456789

10 Units Normal Shut-Off11 mmscfd 4.7 -

12 psig 50013 °F 40-80 -

14 psi -

15 psig16 °F -

17 Kg/m3 -

18 CP -

19 psi20 6321 6422 6523 6624 6725 6826 6927 7028 7129 7230 In 7331 Out 7432 7533 7634 7735 7836 7937 8038 8139 8240 8341 8442 8543 8644 8745 8846 8947 9048 9149 9250 9351 94 M20 x 1,552 95 Yes (ON PNEUMATIC VALVE)53 9654 9755 98 4 Nos.56 99 WESTLOCK 2649SBYN00042BEI-00

57 ##58 ##59 ##60 ##61 ##62 ##

API 598/API 6DANSI/FCI Leakage Class High Tightness Class VIFire Test API 6FA

Hydrostatic / Pneumatic

TEST

S

ZUEITINA OIL COMPANY

Data Sheets for ESD and Blowdown Valves- PRMS Area

DOC. NO. 2010-0111 REV 0 DATE 30/06/2010

GEN

ERA

L

Tag Number 63-XV-6601PID Number 40227/PR/2/02/150Service Benghazi BranchLine NumberA/essel No.

Flow Rate 4.7 0

NG-051-2"-E40Function Blow Down ValveArea Classification CLASS 1, ZONE 1, GAS GROUP IIA, T3Start-Up Bypass Valve

Maximum Minimum

Fluid Natural GasPhase Gas

Inlet Pressure 770 500

Fluid Density 31

Inlet Temperature 100 35Max. Shutoff Differential Pressure 770

Fluid Viscosity @ OP. TEMP 0.01 to 0.02

Design Pressure 1360Design Temperature 200

-

Spring Return, air piston operated.

Out 2"/ SCH 80 Spring Material

Type Ball Valve (Full Bore) Actuating Medium Inst. Air

SER

VIC

E C

ON

DIT

ION

S

Carbon Steel

LIN

E Line Size & thicknessIn 2"/ SCH 80 Type

Mfr & Model Valvitalia LPS-05-160-CM06Pipe Line Insulation

Critical Press Pc

VALV

E B

OD

Y/B

ON

NET

Size 2" ASME Class 600 lbMax. Press/Temp 1333 Psi / 248°FMfr & Model 54Body/Bonnet Matl ASTM A350 LF2

End

60 / 85 NmActuator Break/Run Torque 315 /120 Nm

Air Failure position Fail OpenValve Breakaway Torque 121 NmValve Run/Seating Torque

Top/Side MountingMaximum Shutoff DP 770 psi

Liner Material/ID N/A Process Connection

RF, Smooth Finish.ASME B16.5 Mechanical Limit Stop Yes

Yes2", RF, 600 lb Speed Control Yes

2", RF, 600 lb On/Off

Flow Direction Bi-directional valve Max. stroke Time 1 Sec for Nominal inch

AC

TUA

TOR

End Ext/Matl Not Applicable Handwheel NoFig Face Finish

Local Control Cabinet

Bolts / Nuts ASTM A193 Gr B7M / A194 Gr 2HM

Type of Bonnet StandardLub & Iso Valve YesPacking Material PTFE or Equivalent

Seat Ring Material

CSYes (Mechanical)Stainless Steel

Body/Bonnet Gasket Spiral Wound SS316L with Graphite Filler Mfr & Model MAXSEAL IFR3 1/4" NPT

Enclosure MaterialLocal Position Indicator

Instrument Air

TRIM

Type Ball Filter Reg & Gauge

Rated N/ABalanced/Unbalanced N/A Regulator Pressure Range

Size FBCharacteristic On-Off Valve

59,5 psi g (4,1 barg)Relief Valve Set Pressure 87 psi g (6 barg)

REGU

LATO

R

Line Filter Yes

Process Connection 1/2" NPT (F)Yes

Supply Pressure

Valve CLOSE

63-SOV-6601A and 63-SOV-6601B

ASCO NFET8327B2023/2 Way/316 SS

Mfr. & ModelBall ASTM A182 F316 Tag Number

17-4-PH / ASTM A182 F316 Type & Material

DEVLON Voltage RatingASTM A182 F316 Solenoid Energised

SPEC

IALS

/A

CC

ESSO

RIE

S

Conduit Connection SizeAir Accumulator N/A

Local Reset

- Capacity N/A

N.A.

SOLE

NO

ID V

ALV

E

SealsOther seal VITON AED + GRAPHITE Enclosure Class / Material EEx'd'/316 SS

Manual Reset

24VDC ± 10%

Stem/Trunnion

Valve Control Panel Required, SS 316, IP 65 Mfr & Model

IP 67

LIM

IT S

WIT

CH

Partial Stroking Facility Not Required Contacts Rating 24V DC @ 1A

Quantity

Hydraulic Power Pack Not Required Enclosure Class / Material

N/A Type Proximity Type, Hermetical Seal, DPDT- Pressure Switch N/A- Relief Valve

Page 48: Cover pneumatic valves.pdf · 2013. 9. 10. · API 598/API 6D API 6FA ANSI/FCI Leakage Class High Tightness Class VI Fire Test Local Reset Yes TESTS Hydrostatic / Pneumatic ... Area

123456789

10 Units Normal Shut-Off11 mmscfd HOLD -

12 psig 74013 °F 55-120 -

14 psi -

15 psig16 °F -

17 Kg/m3 -

18 CP -

19 psi20 6321 6422 6523 6624 6725 6826 6927 7028 7129 7230 In 7331 Out 7432 7533 7634 7735 7836 7937 8038 8139 8240 8341 8442 8543 8644 8745 8846 8947 9048 9149 9250 9351 94 M20 x 1,552 95 Yes (ON PNEUMATIC VALVE)53 9654 9755 98 4 Nos.56 99 WESTLOCK 2649SBYN00042BEI-00

57 10058 10159 10260 10361 10462 105

Hydrostatic / Pneumatic

TEST

S

Valvitalia LPS-07-235-CM08B

Fire Test API 6FAANSI/FCI Leakage Class High Tightness Class VI

ZUEITINA OIL COMPANY

Service

FunctionArea ClassificationStart-Up Bypass Valve

API 598/API 6D

HOLD

133 / 186 Nm

Mfr & Model

125 50Max. Shutoff Differential Pressure 1292

Shut Down ValveCLASS 1, ZONE 1, GAS GROUP HA, T3

0

Tag Number 63-XV-6101PID Number 40227/PR/2/02/120

Data Sheets for ESD and Blowdown Valves- PRMS Area

Water Bath Heater E10 InletLine NumberA/essel No. FG-011-4"-E40

DOC. NO. 2010-0111 REV

GEN

ERA

L

DATE 30/06/2010

SER

VIC

E C

ON

DIT

ION

S

Fluid Natural GasPhase Gas

Maximum MinimumFlow Rate

Inlet Temperature

HOLDInlet Pressure 1292 738

Fluid Density 46.8Fluid Viscosity @ OP. TEMP 0.01 to 0.02

Design Pressure 1360Design Temperature 200

Critical Press Pc -

Spring Return, air piston operated.Carbon Steel

LIN

E Line Size & thicknessIn 4" / SCH 80 TypeOut 4" / SCH 80 Spring Material

VALV

E B

OD

Y/B

ON

NET

Type Ball Valve (Reduced Bore) Actuating MediumDouble block & bleed Required Air Failure positionSize 4" ASME Class 600 lb

Liner Material/ID

Max. Press/Temp 1333 Psi / 248 °F Valve Run/Seating Torque

Inst. Air Fail Close

Valve Breakaway Torque 266 Nm

YesEnd Conn.

4", RF, 600 lb On/Off4", RF, 600 lb Speed Control

54 Actuator Break/Run TorqueBody/Bonnet Matl ASTM A350 LF2

N/A Process Connection

Yes

Pipe Line Insulation

1092 /331 Nm1292 psiTop/Side Mounting

Mfr & ModelMaximum Shutoff DP

Yes

1 Sec for Nominal inchEnd Ext/Matl Not Applicable Handwheel No

Stainless Steel

Type of Bonnet Standard Enclosure MaterialLub & Iso Valve Local Position Indicator

CSYes (Mechanical)

Flow Direction Bi-directional valve Max. stroke Time

Yes

Body/Bonnet Gasket Spiral Wound SS316L with Graphite Filler Mfr & Model

AC

TUA

TOR

Fig Face Finish

Packing Material PTFE or Equivalent Local Control Cabinet

RF, Smooth Finish.ASME B16.5 Mechanical Limit Stop

Bolts / Nuts ASTM A193 Gr B7M / A194 Gr 2HM Process Connection

TRIM

CharacteristicBalanced/Unbalanced N/A Regulator Pressure RangeRatedBall

YesSize RB Line Filter YesType Ball Filter Reg & Gauge

59,5 psi g (4,1 barg)87 psi g (6 barg)

REGU

LATO

R

On-Off Valve Supply Pressure Instrument Air

MAXSEAL IFR3 1/4" NPT1/2" NPT (F)

N/A Relief Valve Set Pressure

DEVLON Voltage Rating

ASTM A182 F316 Tag NumberMfr. & Model

Seat Ring Material ASTM A182 F316 Solenoid EnergisedStem/Trunnion 17-4-PH / ASTM A182 F316 Type & Material

Valve OPEN

Enclosure Class / Material EEx'd'/316 SS

SOLE

NO

ID V

ALV

E

63-SOV-6101A and 63-SOV-6101B

ASCO NFET8327B2023/2 Way/ 316 SS

24VDC± 10%Seals

- Relief Valve N/A

Other seal VITON AED + GRAPHITE

Type Proximity Type, Hermetical Seal, DPDT

Conduit Connection SizeManual Reset

SPEC

IALS

/A

CC

ESSO

RIE

S

Air Accumulator N/A- Capacity N/A

- Pressure Switch N/AValve Control Panel

Enclosure Class / Material IP 67

Required, SS 316, IP 65QuantityMfr & ModelContacts Rating

Local Reset N.A.

LIM

IT S

WIT

CH

Partial Stroking Facility Required, Local 24V DC @ 1A

Hydraulic Power Pack Not Required

Page 49: Cover pneumatic valves.pdf · 2013. 9. 10. · API 598/API 6D API 6FA ANSI/FCI Leakage Class High Tightness Class VI Fire Test Local Reset Yes TESTS Hydrostatic / Pneumatic ... Area

123456789

10 Units Normal Shut-Off

11 mmscfd HOLD -

12 psig 74013 °F 55-120 -

14 psi -

15 psig16 °F -

17 Kg/m3 -

18 CP -

19 psi20 6321 6422 6523 6624 6725 6826 6927 7028 7129 7230 In 7331 Out 7432 7533 7634 7735 7836 7937 8038 8139 8240 8341 8442 8543 8644 8745 8846 8947 9048 9149 9250 9351 94 M20 x 1,552 95 Yes (ON PNEUMATIC VALVE)53 9654 9755 98 4 Nos.56 99 WESTLOCK 2649SBYN00042BEI-00

57 10058 10159 10260 10361 10462 105 Fire Test

Hydrostatic / PneumaticANSI/FCI Leakage Class High Tightness Class VI

TEST

S

API 6FA

API 598/API 6D

HOLD

Carbon SteelValvitalia LPS-07-235-CM08B

1092 /331 Nm

Valve Breakaway Torque 266 Nm

Local Reset N.A.Hydraulic Power Pack Not Required

Service Water Bath Heater E20 InletLine NumberA/essel No. NG-013-4"-E40Function Shut Down ValveArea Classification CLASS 1, ZONE 1, GAS GROUP HA, T3

ZUEITINA OIL COMPANY

Data Sheets for ESD and Blowdown Valves- PRMS Area

DOC. NO. 2010-0111 REV 0 DATE 30/06/2010

Start-Up Bypass Valve

GEN

ERA

L

Tag Number 63-XV-6103PID Number 40227/PR/2/02/120

SER

VIC

E C

ON

DIT

ION

S

Fluid Natural GasPhase Gas

Maximum MinimumFlow Rate HOLDInlet Pressure 1292 738

Fluid Density 46.8

Inlet Temperature 125 50Max. Shutoff Differential Pressure 1292

Fluid Viscosity @ OP. TEMP 0.01 to 0.02

Design Pressure 1360Design Temperature 200

LIN

E Line Size & thicknessIn 4"/ SCH 80 TypeOut 4"/ SCH 80 Spring Material

Mfr & Model

Critical Press Pc -

Spring Return, air piston operated.

Pipe Line Insulation

VALV

E B

OD

Y/B

ON

NET

Type Ball Valve (Reduced Bore)Double block & bleed RequiredSize 4" ASME Class 600 lbMax. Press/Temp 1333 Psi / 248°F

End Conn.Yes

Valve Run/Seating Torque 133 / 186 Nm

Actuating Medium Inst. AirAir Failure position Fail Close

Top/Side MountingBody/Bonnet Matl ASTM A350 LF2 Maximum Shutoff DP 1292 psiLiner Material/ID N/A Process Connection

RF, Smooth Finish.ASME B16.5

Mfr & Model 54 Actuator Break/Run Torque

Mechanical Limit Stop4", RF, 600 lb Speed Control

On/OffYes

4", RF, 600 lb

Flow Direction Bi-directional valve Max. stroke Time 1 Sec for Nominal inch

Yes

End Ext/Mat! Not Applicable Handwheel NoFig Face Finish

Stainless Steel

AC

TUA

TOR

Lub & I so Valve Yes Local Position Indicator Yes (Mechanical)Type of Bonnet Standard Enclosure Material CS

Packing Material PTFE or Equivalent Local Control CabinetBody/Bonnet Gasket Spiral Wound SS316L with Graphite Filler Mfr & Model

59,5 psi g (4,1 barg)

MAXSEAL IFR3 1/4" NPT1/2" NPT (F)

Type Ball Filter Reg & GaugeBolts / Nuts

Instrument Air

ASTM A193 Gr B7M / A194 Gr 2HM Process Connection

CharacteristicSize RB Line Filter Yes

Mfr. & Model

On-Off Valve Supply PressureBalanced/Unbalanced N/A Regulator Pressure Range

87 psi g (6 barg)Ball ASTM A182 F316 Tag Number 63-SOV-6103A and 63-SOV-6103BRated N/A Relief Valve Set Pressure

REGU

LATO

R

Yes

3/2 Way/316 SSSeat Ring Material ASTM A182 F316 Solenoid Energised Valve OPEN

SOLE

NO

ID V

ALV

E ASCO NFET8327B20217-4-PH / ASTM A182 F316 Type & Material

Seals

SPEC

IALS

/A

CC

ESSO

RIE

S

Conduit Connection SizeAir Accumulator

Partial Stroking Facility Not RequiredRequired, SS 316, IP 65

Enclosure Class / Material

Valve Control Panel

TRIM

Manual Reset- Capacity N/A

DEVLON Voltage Rating

Stem/Trunnion

VITON AED + GRAPHITE Enclosure Class / Material

- Pressure SwitchMfr & Model

- Relief Valve N/A TypeN/A Quantity

24VDC± 10%EEx'd'/316 SS

24V DC @ 1A

LIM

IT S

WIT

CH

Contacts RatingIP 67

N/A

Other seal

Proximity Type, Hermetical Seal, DPDT

Page 50: Cover pneumatic valves.pdf · 2013. 9. 10. · API 598/API 6D API 6FA ANSI/FCI Leakage Class High Tightness Class VI Fire Test Local Reset Yes TESTS Hydrostatic / Pneumatic ... Area

123456789

10 Units Normal Shut-Off11 mmscfd 43.6 -

12 psig 72813 °F 60-95 -

14 psi -

15 psig16 °F -

17 Kg/m3 -

18 CP -

19 psi20 6321 6422 6523 6624 6725 6826 6927 7028 7129 7230 In 7331 Out 7432 7533 7634 7735 7836 7937 8038 8139 8240 8341 8442 8543 8644 8745 8846 8947 9048 9149 9250 9351 94 M20 x 1,552 95 Yes (ON PNEUMATIC VALVE)53 9654 9755 98 4 Nos.56 99 WESTLOCK 2649SBYN00042BEI-00

57 10058 10159 10260 10361 10462 105 API 6FAFire Test

ANSI/FCI Leakage Class High Tightness Class VI

DOC. NO. 2010-0111

Line NumberA/essel No. NG-053-3"-E40

TEST

S

Minimum

Function

REV 0 DATE 30/06/2010

GEN

ERA

L

Tag Number 63-XV-6203PID Number 40227/PR/2/02/101Service PRMS Plant Inlet blowdown

Blow Down ValveArea Classification CLASS 1, ZONE 1, GAS GROUP HA, T3

Hydrostatic / Pneumatic API 598/API 6D

720

Start-Up Bypass Valve

Max. Shutoff Differential Pressure 1292

SER

VIC

E C

ON

DIT

ION

S

Fluid Natural GasPhase Gas

Maximum

Inlet Temperature 125 55

Flow Rate 43.6 0Inlet Pressure 1292

Fluid DensityFluid Viscosity @ OP. TEMP 0.01 to 0.02

Design Pressure 1360 r }J . ■

Design Temperature 200

LIN

E Line Size & thicknessIn 3" / SCH 80 TypeOut 3" / SCH 80 Spring Material Carbon Steel

Mfr & Model Valvitalia LPS-05-235-CM09

Critical Press PcSpring Return, air piston operated.

1333 Psi / 248°FValve Run/Seating Torque 133 / 186 Nm

Ball Valve (Full Bore) Actuating Medium

Body/Bonnet Matl ASTM A350 LF2 Actuator Break/Run Torque 653 /250 NmMfr & Model

Inst. AirFail Open

Valve Breakaway Torque 266 Nm54

Size 3" ASME Class 600 lb Air Failure positionMax. Press/Temp

Liner Material/ID N/A Process Connection Top/Side MountingMaximum Shutoff DP 1292 psi

3", RF, 600 lb On/Off Yes3", RF, 600 lb Speed Control Yes

NoFig Face Finish RF, Smooth Finish.ASME B16.5 Mechanical Limit Stop Yes

VALV

E B

OD

Y/B

ON

NET

Type

Lub & Iso Valve Yes

Body/Bonnet Gasket Spiral Wound SS316L with Graphite FillerBolts / Nuts ASTM A193 Gr B7M / A194 Gr 2HM

Standard

End Conn.

Local Position Indicator

End Ext/Matl Not Applicable HandwheelMax. stroke Time

Type of Bonnet Enclosure Material

TRIM

YesSize FB Line Filter Yes

N/A

Type Ball Filter Reg & Gauge

Characteristic

Local Control Cabinet Stainless SteelMAXSEAL IFR3 1/4" NPT1/2 " NPT (F)Process Connection

Instrument Air Balanced/Unbalanced N/A Regulator Pressure Range 59,5 psi g (4,1 barg)

On-Off Valve REGU

LATO

R

Mfr & Model

Rated

Supply Pressure

ASTM A182 F316 Solenoid EnergisedStem/Trunnion

Ball ASTM A182 F316 Tag Number

17-4-PH / ASTM A182 F316

Other seal VITON AED + GRAPHITE Enclosure Class / MaterialSeals DEVLON Voltage Rating

Mfr. & Model

Seat Ring Material

SPEC

IALS

/A

CC

ESSO

RIE

S

Conduit Connection SizeAir Accumulator N/A

Valve Control Panel- Pressure Switch

- Capacity N/A

SOLE

NO

ID V

ALV

E

24VDC± 10%EEx'd'/316SS

63-SOV-6203A and 63-SOV-6203BASCO NFET8327B2023/2 Way/316 SSValve CLOSE

Type & Material

N/A Quantity

Partial Stroking Facility Not Required Contacts RatingRequired, SS316, IP 65

Local Reset N.A.

LIM

IT S

WIT

CH

Hydraulic Power Pack Not Required

- Relief Valve N/A Type

ZUEITINA OIL COMPANY

Data Sheets for ESD and Blowdown Valves- PRMS Area

Pipe Line Insulation

AC

TUA

TOR

1 Sec for Nominal inchCS

Packing Material

Flow Direction Bi-directional valve

Yes (Mechanical)

Enclosure Class / Material

PTFE or Equivalent

Proximity Type, Hermetical Seal, DPDT

Mfr & Model24V DC @ 1A

Manual Reset

Relief Valve Set Pressure 87 psi g (6 barg)

IP 67

Page 51: Cover pneumatic valves.pdf · 2013. 9. 10. · API 598/API 6D API 6FA ANSI/FCI Leakage Class High Tightness Class VI Fire Test Local Reset Yes TESTS Hydrostatic / Pneumatic ... Area

123456789

10 Units Normal Shut-Off11 mmscfd 24,6 -

12 psig 72813 °F 95 -

14 psi15 psig16 °F -

17 Kg/m3 -

18 CP -

19 psi20 6321 6422 6523 6624 6725 6826 6927 7028 7129 7230 In 7331 Out 7432 7533 7634 7735 7836 7937 8038 8139 8240 8341 8442 8543 8644 8745 8846 8947 9048 9149 9250 9351 94 M20 x 1,552 95 Yes (ON PNEUMATIC VALVE)53 9654 9755 98 4 Nos.56 99 WESTLOCK 2649SBYN00042BEI-00

57 10058 10159 10260 10361 10462 105

Line NumberA/essel No. NG-049-2"-E40

ZUEITINA OIL COMPANY

Data Sheets for ESD and Blowdown Valves- PRMS Area

DOC. NO. 2010-0111

Service

GEN

ERA

LBlow Down Valve

REV 0 DATE 30/06/2010

Benghazi Branch metering outlet

Area Classification CLASS 1, ZONE 1, GAS GROUP HA, T3Start-Up Bypass Valve

Tag Number 63-XV-6403PID Number 40227/PR/2/02/139

FunctionSE

RVI

CE

CO

ND

ITIO

NS

Fluid Natural GasPhase Gas

Maximum MinimumFlow Rate 24,6

Max. Shutoff Differential Pressure 1292Design Pressure 1360

Inlet Pressure 1292 720Inlet Temperature 125 90

Fluid Viscosity @ OP. TEMP 0.01 to 0.02Critical Press Pc -

Design Temperature 200Fluid Density 46.8

Spring Return, air piston operated.Out 2" / SCH 80 Spring Material Carbon Steel

LIN

E Line Size & thicknessIn 2" / SCH 80 Type

Pipe Line Insulation Mfr & Model Valvitalia LPS-05-160-CM06

Type Ball Valve (Full Bore) Actuating Medium

60 / 85 NmBody/Bonnet Matl

Size 2" ASME Class 600 lb Air Failure position

54 Valve Run/Seating Torque

VALV

E B

OD

Y/B

ON

NET

Inst. AirFail Open

Max. Press/Temp 1333 Psi / 248°F Valve Breakaway Torque 121 NmMfr& Model

1292 psiTop/Side Mounting

ASTM A350 LF2 Actuator Break/Run Torque 315 /120 Nm

Liner Material/ID N/A

Mechanical Limit Stop

End Conn.2", RF, 600 lb2", RF, 600 lb

Maximum Shutoff DPProcess Connection

Yes

YesOn/OffSpeed Control Yes

End Ext/Matl Not ApplicableFig Face Finish RF, Smooth Finish.ASME B16.5

Flow Direction Bi-directional valve Max. stroke TimeType of Bonnet Standard Enclosure Material

No1 Sec for Nominal inch

Spiral Wound SS316L with Graphite FillerStainless Steel

Mfr & Model MAXSEAL IFR3 1/4" NPT

Yes (Mechanical)PTFE or Equivalent Local Control Cabinet

Lub & Iso Valve Yes Local Position IndicatorPacking Material

AC

TUA

TOR

Handwheel

CS

1/2" NPT (F)

TRIM

Type Ball Filter Reg & Gauge YesSize FB Line Filter

Bolts / Nuts

87 psi g (6 barg)

YesCharacteristic On-Off Valve Supply Pressure Instrument AirBalanced/Unbalanced N/A Regulator Pressure Range 59,5 psi g (4,1 barg)

17-4-PH / ASTM A182 F316 Type & Material

Rated N/A Relief Valve Set Pressure

REGU

LATO

R

ASTM A193 Gr B7M / A194 Gr 2HM Process ConnectionBody/Bonnet Gasket

63-SOV-6403A and 63-SOV-6403BASCO NFET8327B2023/2 Way/316 SS

Ball ASTM A182 F316 Tag NumberMfr. & Model

Stem/TrunnionValve CLOSE

Manual Reset

EEx'd'/316 SS24VDC±10%Voltage Rating

Enclosure Class / Material

ASTM A182 F316 Solenoid Energised

Air Accumulator

Seat Ring MaterialSeals DEVLON

SPEC

IALS

/A

CC

ESSO

RIE

S - Capacity N/A

Hydraulic Power Pack Enclosure Class / MaterialLocal Reset N.A.

Valve Control Panel

- Relief Valve N/A

Other seal VITON AED + GRAPHITE

N/AConduit Connection Size

SOLE

NO

ID V

ALV

E

Type Proximity Type, Hermetical Seal, DPDTQuantityMfr & Model

24V DC @ 1ANot Required

LIM

IT S

WIT

CHN/A

Required, SS 316, IP 65Contacts Rating

IP 67

API 598/API 6DHydrostatic / Pneumatic

TEST

S ANSI/FCI Leakage Class High Tightness Class VIFire Test API 6FA

Not RequiredPartial Stroking Facility

- Pressure Switch

Page 52: Cover pneumatic valves.pdf · 2013. 9. 10. · API 598/API 6D API 6FA ANSI/FCI Leakage Class High Tightness Class VI Fire Test Local Reset Yes TESTS Hydrostatic / Pneumatic ... Area

123456789

10 Units Normal Shut-Off11 mmscfd 41.2 -

12 psig 47013 °F 100 -

14 psi I

15 psig16 °F -

17 Kg/m3 -

18 CP -

19 psi20 6321 6422 6523 6624 6725 6826 6927 7028 7129 7230 In 7331 Out 7432 7533 7634 7735 7836 7937 8038 8139 8240 8341 8442 8543 8644 8745 8846 8947 9048 9149 9250 9351 94 M20 x 1,552 95 Yes (ON PNEUMATIC VALVE)53 9654 9755 98 4 Nos.56 99 WESTLOCK 2649SBYN00042BEI-0057 10058 10159 10260 10361 10462 105

Line NumberA/essel No. NG-108-6"-E41 |

ZUEITINA OIL COMPANY

Data Sheets for ESD and Blowdown Valves- 103A Area

DOC. NO. 2010-0111

ServiceG

ENER

AL

Blow Down Valve

REV 0 DATE 30/06/2010

Al Faregh Stream Blowdown

Area Classification CLASS 1, ZONE 1, GAS GROUP IIA, T3Start-Up Bypass Valve

Tag Number 62-XV-6900PID Number 40227/PR/1/02/002

Function

SER

VIC

E C

ON

DIT

ION

S

Fluid Natural GasPhase Gas

Maximum MinimumFlow Rate

Max. Shutoff Differential Pressure 699

0Inlet Pressure 635 430

41.2

Inlet Temperature 100 98

Fluid Density 25.2Fluid Viscosity @ OP. TEMP 0.01

Design Pressure 1360Design Temperature 200

LIN

E Line Size & thicknessIn 6"/ SCH 80 TypeOut 6"/ SCH 80 Spring Material Carbon Steel

Mfr & Model Valvitalia LPS-07-320-CM12

Critical Press Pc -

Spring Return, air piston operated.

VALV

E B

OD

Y/B

ON

NET

Type Ball Valve (Full Bore) Actuating Medium

Max. Press/Temp 1333 Psi / 248°F Valve Breakaway Torque

Body/Bonnet Matl ASTM A350 LF2

Liner Material/ID

848 NmMfr & Model 55 Valve Run/Seating Torque 421 / 594 Nm

Inst. AirSize 6" ASME Class 600 lb Air Failure position Fail Open

Actuator Break/Run Torque

Top/Side Mounting

1342 /656 NmMaximum Shutoff DP 699 psi

N/A Process Connection

Fig Face Finish RF, Smooth Finish.ASME B16.5 Mechanical Limit Stop Yes

Handwheel

6", RF, 600 lb Speed Control Yes

6", RF, 600 lb On/Off Yes

Type of Bonnet Standard Enclosure Material

Not Required

Flow Direction Bi-directional valve Max. stroke Time 1 Sec for Nominal inch

End Ext/Matl Not Applicable

Lub & Iso Valve Yes Local Position Indicator Required (Mechanical)

AC

TUA

TOR

Pipe Line Insulation

End

Packing Material PTFE or Equivalent Local Control Cabinet

Bolts / Nuts ASTM A193 Gr B7M / A194 Gr 2HM Process Connection 1/2 " NPT (F)Body/Bonnet Gasket Spiral Wound SS316L with Graphite Filler Mfr & Model MAXSEAL IFR3 1/4" NPT

TRIM

Type Ball Filter Reg & Gauge

Balanced/Unbalanced N/A Regulator Pressure Range

Ball ASTM A182 F316 Tag Number

RequiredCharacteristic On-Off Valve Supply Pressure Instrument Air

Line Filter

59,5 psi g (4,1 barg)

62-SOV-6900A and 62-SOV-6900BRated N/A Relief Valve Set Pressure 87 psi g (6 barg)

REGU

LATO

R

RequiredSize FB

ASCO NFET8327B202Stem/Trunnion 17-4-PH

SOLE

NO

ID V

ALV

E

24VDC + 10%Seat Ring Material

Conduit Connection SizeEEx'd'/316 SS

Type & Material

N/A Quantity

Mfr. & Model

Other seal VITON AED + GRAPHITE Enclosure Class / Material

Air Accumulator

- Relief Valve Proximity Type, Hermetical Seal, DPDT- Capacity N/A

3/2 Way/316 SS

Valve CLOSESeals DEVLON Voltage Rating

ASTM A182 F316 Solenoid Energised

Valve Control Panel Required, SS 316, IP 65 Mfr & Model

N/A Manual Reset

N/A Type- Pressure Switch

Partial Stroking Facility Not Required Contacts RatingHydraulic Power Pack

24V DC @ 1A

ANSI/FCI Leakage Class High Tightness Class VI

Not Required Enclosure Class / Material

TEST

S

Stainless Steel

CS

SPEC

IALS

/ A

CC

ESSO

RIE

S

LIM

IT S

WIT

CH

IP 67Local Reset N.A.

Fire Test API 6FA

Hydrostatic / Pneumatic API 598/API 6D

Page 53: Cover pneumatic valves.pdf · 2013. 9. 10. · API 598/API 6D API 6FA ANSI/FCI Leakage Class High Tightness Class VI Fire Test Local Reset Yes TESTS Hydrostatic / Pneumatic ... Area

123456789

10 Units Normal Shut-Off11 mmscfd 94.2 -

12 psig 133813 °F 127 -

14 psi -

15 psig16 °F -

17 Kg/m3 -

18 CP -

19 psi20 6321 6422 6523 6624 6725 6826 6927 7028 7129 7230 In 7331 Out 7432 7533 7634 7735 7836 7937 8038 8139 8240 8341 8442 8543 8644 8745 8846 8947 9048 9149 9250 9351 94 M20 x 1,552 95 Yes (ON PNEUMATIC VALVE)53 9654 9755 98 4 Nos. 56 99 WESTLOCK 2649SBYN00042BEI-0057 10058 10159 10260 10361 10462 105

ZUEITINA OIL COMPANY

Data Sheets for ESD and Blowdown Valves- 103A Area

DOC. NO. 2010-0111 #REF! 0 DATE 30/06/2010

NG-113-6"-F40Function Blow Down Valve

62-XV-6084PID Number 40227/PR/1/02/115Service Metering station to flare

Inlet Temperature 130 125

GEN

ERA

LTag Number

Area Classification CLASS 1, ZONE 1, GAS GROUP IIA, T3

Start-Up Bypass Valve

Line NumberA/essel No.

Inlet Pressure 1338 775Flow Rate 94.2 0

Design Pressure 1480Design Temperature

Max. Shutoff Differential Pressure 1338

Phase GasMaximum Minimum

Fail Open

Spring Return, air piston operated.

55

Spring Material Carbon SteelMfr & Model Valvitalia LPS-99-230-SC5

Inst. Air

In 6" / SCH 80 Type

SER

VIC

E C

ON

DIT

ION

S

Fluid Natural Gas

Fluid Density 44-78.3300

Critical Press Pc -

Fluid Viscosity @ OP. TEMP 0.01 to 0.02

LIN

E Line Size & thickness

Max. Press/Temp 1998 Psi / 248°F

Out 6"/ SCH 80

VALV

E B

OD

Y/B

ON

NET

Type Ball Valve (Full Bore) Actuating MediumSize 6" ASME Class 900 lb Air Failure position

Mfr & Model

Process Connection Top/Side MountingMaximum Shutoff DP

Body/Bonnet Mat! ASTM A350 LF2Valve Run/Seating Torque 266 / 345 Nm

Speed Control

Valve Breakaway Torque 788 Nm

Actuator Break/Run Torque 1387 /543 Nm

Yes

1338 psi

On/Off Yes

1 Sec for Nominal inch

Fig Face Finish RF, Smooth Finish.ASME B16.5 Mechanical Limit StopEnd Ext/Matl Not Applicable Handwheel Not Required

Yes

CS

End

Yes Local Position Indicator Required (Mechanical)Type of Bonnet Standard Enclosure Material

AC

TUA

TOR

Pipe Line Insulation

Process Connection

Flow Direction Bi-directional valve

Mfr & Model

REGU

LATO

R

Line Filter

6", RF, 900 lb

Packing Material PTFE or Equivalent

N/ABalanced/Unbalanced

Bolts / Nuts ASTM A193 Gr B7M / A194 Gr 2HM

Relief Valve Set Pressure

Local Control CabinetLub & Iso Valve

Max. stroke Time

Liner Material/ID N/A

On-Off Valve Supply Pressure

ASTM A182 F316 LN + ENP 0,001"

Body/Bonnet Gasket Spiral Wound SS316L with Graphite Filler

FB

Stainless Steel

TRIM

Type Ball Filter Reg & Gauge

Characteristic

Mfr. & Model ASCO NFET8327B202

Rated N/A

MAXSEAL IFR3 1/4" NPT

87 psi g (6 barg)Tag Number 62-SOV-6084A and 62-SOV-6084B

Regulator Pressure Range 59,5 psi g (4,1 barg)

1/2 " NPT (F)

RequiredInstrument Air

Required

Valve CLOSEStem/Trunnion 17-4-PH + ENP 0,001" Type & Material 3/2 Way/316 SS

Solenoid EnergisedASTM A182 F316 LN + ENP 0,001"

EEx'd'/316 SSSeals VITON AED Voltage Rating 24VDC± 10%

Enclosure Class / MaterialOther seal VITON AED + GRAPHITEConduit Connection Size

Air Accumulator N/A Manual Reset

- Relief Valve N/A Type Proximity Type, Hermetical Seal, DPDT- Capacity N/A

SOLE

NO

ID V

ALV

E

Seat Ring Material

Contacts Rating 24V DC @ 1A

QuantityValve Control Panel Required, SS 316, IP 65 Mfr & ModelPartial Stroking Facility

- Pressure Switch N/A

Hydraulic Power Pack Not Required Enclosure Class / Material IP 67

TEST

S

API 598/API 6D

ANSI/FCI Leakage Class High Tightness Class VIFire Test API 6FA

Hydrostatic / Pneumatic

6", RF, 900 lb

SPEC

IALS

/ A

CC

ESSO

RIE

S

LIM

IT S

WIT

CH

Local Reset N.A.

Not Required

Size

Ball

Page 54: Cover pneumatic valves.pdf · 2013. 9. 10. · API 598/API 6D API 6FA ANSI/FCI Leakage Class High Tightness Class VI Fire Test Local Reset Yes TESTS Hydrostatic / Pneumatic ... Area

123456789

10 Units Normal Shut-Off11 mmscfd 1.6 -

12 psig 363 - 39213 °F 100 -

14 psi -

15 psig16 °F -

17 Kg/m3 -

18 CP -

19 psi20 6321 6422 6523 6624 6725 6826 6927 7028 7129 7230 In 7331 Out 7432 7533 7634 7735 7836 7937 8038 8139 8240 8341 8442 8543 8644 8745 8846 8947 9048 9149 9250 9351 94 M20 x 1,552 95 Yes (ON PNEUMATIC VALVE)53 9654 9755 98 4 Nos.56 99 WESTLOCK 2649SBYN00042BEI-0057 10058 10159 10260 10361 10462 105

Line NumberA/essel No. FG-007-2"-CA37

ZUEITINA OIL COMPANY

Data Sheets for ESD and Blowdown Valves- 103A Area

DOC. NO. 2010-0111

ServiceG

ENER

AL

Blow Down Valve

REV 0 DATE 30/06/2010

Fuel Gas Skid to flare

Area Classification CLASS 1, ZONE 1, GAS GROUP HA, T3Start-Up Bypass Valve

Tag Number 62-XV-6871PID Number 40227/PR/1/02/207

Function

SER

VIC

E C

ON

DIT

ION

S

Fluid Natural GasPhase Gas

Maximum MinimumFlow Rate

Max. Shutoff Differential Pressure 435

0Inlet Pressure 435 363

1.6

Inlet Temperature 100 55

Carbon Steel

Design Pressure 435Design Temperature 200Fluid Density 23.42Fluid Viscosity @ OP. TEMP 0.011

Process Connection

Critical Press Pc -

LIN

E Line Size & thicknessIn 2"/ SCH 40 Type Spring Return, air piston operated.Out 2"/ SCH 40 Spring Material

Top/Side Mounting

VALV

E B

OD

Y/B

ON

NET

Type Ball Valve (Full Bore) Actuating MediumSize 2" ASME Class 300 lb Air Failure position

Liner Material/ID N/A

121 NmMax. Press/Temp 665 Psi / 248°F

Inst. Air Fail Open

Valve Breakaway TorqueMfr & Model 54 Valve Run/Seating Torque 60 / 85 NmBody/Bonnet Matl 315 /120 Nm

Maximum Shutoff DP 435 psiASTM A350 LF2 Actuator Break/Run Torque

2", RF, 300 lb On/Off Yes2", RF, 300 lb Speed Control Yes

AC

TUA

TOR

Valvitalia LPS-05-160-CM06Pipe Line Insulation Mfr & Model

End Ext/Matl Not ApplicableFig Face Finish RF, Smooth Finish.ASME B16.5 Mechanical Limit Stop Yes

Handwheel

Type of Bonnet Standard Enclosure Material CSFlow Direction Bi-directional valve Max. stroke Time 1 Sec for Nominal inch

Required (Mechanical)

Not Required

Packing Material PTFE or Equivalent Local Control Cabinet Stainless SteelLub & I so Valve Yes Local Position Indicator

MAXSEAL IFR3 1/4" NPTBolts / Nuts ASTM A193 Gr B7M / A194 Gr 2HM Process Connection 1/2" NPT (F)Body/Bonnet Gasket Spiral Wound SS316L with Graphite Filler

REGU

LATO

R

Mfr & Model

Required

TRIM

Type Ball Filter Reg & Gauge

Characteristic On-Off Valve Supply Pressure

Rated

Stem/Trunnion ASTM A182 F316

RequiredInstrument Air

Balanced/Unbalanced N/A Regulator Pressure Range 59,5 psi g (4,1 barg)

Size FB Line Filter

87 psi g (6 barg)Ball ASTM A182 F316 Tag Number 62-SOV-6871A & 62-SOV-6871B

N/A Relief Valve Set Pressure

Mfr. & Model ASCO NFET8327B202

EEx'd'/316 SSSeals DEVLON Voltage Rating 24VDC± 10%Other seal VITON AED+GRAPHITE Enclosure Class / Material

3/2 Way/316 SSSeat Ring Material ASTM A182 F316 Solenoid Energised Valve CLOSE

Type & Material

Conduit Connection SizeAir Accumulator N/A Manual Reset

- Relief Valve N/A Type Proximity Type, Hermetical Seal, DPDT

- Capacity N/A

QuantityValve Control Panel Required, SS 316, IP 65 Mfr & Model- Pressure Switch N/A

Not Required Contacts Rating 24V DC @ 1AHydraulic Power Pack Not Required Enclosure Class / Material IP 67Partial Stroking Facility

API 598/API 6DANSI/FCI Leakage Class High Tightness Class VIFire Test API 6FA

Hydrostatic / Pneumatic

EndSO

LEN

OID

VA

LVE

SPEC

IALS

/ A

CC

ESSO

RIE

S

LIM

IT S

WIT

CH

TEST

S

Local Reset N.A.

Page 55: Cover pneumatic valves.pdf · 2013. 9. 10. · API 598/API 6D API 6FA ANSI/FCI Leakage Class High Tightness Class VI Fire Test Local Reset Yes TESTS Hydrostatic / Pneumatic ... Area

123456789

10 Units Normal Shut-Off11 mmscfd 35.9 -

12 psig 75013 °F 55-120 -

14 psi I

15 psig16 °F -

17 Kg/m3 -

18 CP -

19 psi20 6321 6422 6523 6624 6725 6826 6927 7028 7129 7230 In 7331 Out 7432 7533 7634 7735 7836 7937 8038 8139 8240 8341 8442 8543 8644 8745 8846 8947 9048 9149 9250 9351 94 M20 x 1,552 95 Yes (ON PNEUMATIC VALVE)53 9654 9755 98 4 Nos. 56 99 WESTLOCK 2649SBYN00042BEI-00

57 10058 10159 10260 10361 10462 105

Hydrostatic / PneumaticANSI/FCI Leakage Class

ZUEITINA OIL COMPANY

Data Sheets for ESD and Blowdown Valves- PRMS Area

DOC. NO. 2010-0111 REV 0 DATE 30/06/2010

GEN

ERA

L

Tag Number 63-XV-6005PID Number 40227/PR/2/02/102Service Filter C-10/20 Inlet HeaderLine NumberA/essel No. NG-045-3"-E40 |Function Blow Down ValveArea Classification CLASS 1, ZONE 1, GAS GROUP IIA, T3 |Start-Up Bypass ValveFluid Natural GasPhase Gas

Maximum Minimum

Max. Shutoff Differential Pressure 1292

Flow Rate 35.9 0

Design Pressure 1360

Inlet Pressure 1292 750Inlet Temperature 125 55

Fluid Viscosity @ OP. TEMP 0.01 to 0.02Critical Press Pc -

Design Temperature 200Fluid Density 46.8

Spring Return, air piston operated.Out 3" / SCH 80 Spring Material

SER

VIC

E C

ON

DIT

ION

S

Carbon Steel

LIN

E Line Size & thicknessIn 3" / SCH 80 Type

Mfr & Model

Mfr & Model 54ASTM A350 LF2 Actuator Break/Run Torque

Valvitalia LPS-05-235-CM09

Type Ball Valve (Full Bore) Actuating Medium Inst. AirPipe Line Insulation

Fail Open266 Nm

Valve Run/Seating Torque 133 / 186 NmValve Breakaway Torque

VALV

E B

OD

Y/B

ON

NET

Size 3" ASME Class 600 lb Air Failure positionMax. Press/Temp 1333 Psi / 248 °F

Mechanical Limit Stop3", RF, 600 lb

Maximum Shutoff DP653 /250 Nm1292 psiTop/Side Mounting

Body/Bonnet Matl

Yes

YesLiner Material/ID N/A Process Connection

YesEnd Conn.

3", RF, 600 lb On/Off

Fig Face Finish RF, Smooth Finish.ASME B16.5Speed Control

AC

TUA

TOR

Lub & Iso Valve Yes

Flow Direction Bi-directional valve

Local Position IndicatorStandard Enclosure Material

Max. stroke TimeNot Applicable Handwheel

Bolts / Nuts ASTM A193 Gr B7M / A194 Gr 2HM Process Connection

End Ext/Mat!

Local Control Cabinet Stainless SteelYes (Mechanical)

No1 Sec for Nominal inchCS Type of Bonnet

On-Off Valve

Body/Bonnet Gasket Spiral Wound SS316L with Graphite FillerPacking Material PTFE or Equivalent

Characteristic59,5 psi g (4,1 barg)

MAXSEAL IFR3 1/4" NPT1/2 "NPT (F)

Rated N/A Relief Valve Set Pressure

Type Ball Filter Reg & Gauge

Balanced/Unbalanced N/A

Size FB

87 psi g (6 barg)

REGU

LATO

R

Supply Pressure Instrument Air Regulator Pressure Range

Yes

Mfr & Model

Stem/Trunnion 17-4-PH / ASTM A182 F316 Type & Material 3/2 Way/316 SS

SOLE

NO

ID V

ALV

E

EEx'd'/316 SS

Ball ASTM A182 F316 Tag NumberMfr. & Model

SealsSeat Ring Material

DEVLON Voltage Rating

Quantity- Relief Valve

Conduit Connection SizeAir Accumulator N/A Manual Reset

63-SOV-6005A and 63-SOV-6005B

Enclosure Class / Material

ASCO NFET8327B202

ASTM A182 F316 Solenoid Energised

VITON AED + GRAPHITE

Valve CLOSE24VDC± 10%

SPEC

IALS

/A

CC

ESSO

RIE

S

Not Required

- Capacity N/A

- Pressure Switch N/A

Not RequiredPartial Stroking Facility

Local Reset N.A.

API 6FA

24V DC @ 1A

Type

Hydraulic Power Pack

Required, SS316, IP 65 Mfr & ModelContacts Rating

Valve Control Panel

Enclosure Class / Material IP 67

TEST

S

TRIM

Line Filter Yes

N/A

Other seal

Proximity Type, Hermetical Seal, DPDT

LIM

IT S

WIT

CH

API 598/API 6DHigh Tightness Class VI

Fire Test