2010 CA08103002Z-EN www.eaton.com Single phase Two phase Three phase Single phase Two phase Three phase Single phase Three phase Single phase Two phase Three phase Single phase Two phase Three phase 1/10 3.0 1.5 1.0 1/8 3.8 1.9 1.2 1/6 4.4 2.2 1.4 1/4 5.8 2.9 1.8 1/3 7.2 3.6 2.3 1/2 9.8 4.0 4.4 4.9 2.0 2.2 3.2 1.3 2.5 1.0 1.1 2.0 0.8 0.9 3/4 13.8 4.8 6.4 6.9 2.4 3.2 4.5 1.8 3.5 1.2 1.6 2.8 1.0 1.3 1 16.0 6.4 8.4 8.0 3.2 4.2 5.1 2.3 4.0 1.6 2.1 3.2 1.3 1.7 1-1/2 20.0 9.0 12.0 10.0 4.5 6.0 6.4 3.3 5.0 2.3 3.0 4.0 1.8 2.4 2 24.0 11.8 13.6 12.0 5.9 6.8 7.7 4.3 6.0 3.0 3.4 4.8 2.4 2.7 3 34.0 16.6 19.2 17.0 8.3 9.6 10.9 6.1 8.5 4.2 4.8 6.8 3.3 3.9 5 56.0 26.4 30.4 28.0 13.2 15.2 17.9 9.7 14.0 6.6 7.6 11.2 5.3 6.1 7-1/2 80.0 38.0 44.0 40.0 19.0 22.0 27.0 14.0 21.0 9.0 11.0 16.0 8.0 9.0 10 100 48.0 56.0 50.0 24.0 28.0 33.0 18.0 26.0 12.0 14.0 20.0 10.0 11.0 15 135 72.0 84.0 68.0 36.0 42.0 44.0 27.0 34.0 18.0 21.0 27.0 14.0 17.0 20 94.0 108 88.0 47.0 54.0 56.0 34.0 44.0 23.0 27.0 35.0 19.0 22.0 25 118 136 110 59.0 68.0 70.0 44.0 55.0 29.0 34.0 44.0 24.0 27.0 30 138 160 136 69.0 80.0 87.0 51.0 68.0 35.0 40.0 54.0 28.0 32.0 40 180 208 176 90.0 104 112 66.0 88.0 45.0 52.0 70.0 36.0 41.0 50 226 260 216 113 130 139 83.0 108 56.0 65.0 86.0 45.0 52.0 60 133 154 103 67.0 77.0 53.0 62.0 75 166 192 128 83.0 96.0 66.0 77.0 100 218 248 165 109 124 87.0 99.0 125 312 208 135 156 108 125 150 360 240 156 180 125 144 200 480 320 208 240 167 192 250 602 403 302 242 300 482 361 289 350 560 414 336 400 636 477 382 500 786 590 472 a) To obtain full-load currents for 200 and 208 V motors, increase corresponding 220 - 240 V ratings by 15 and 10 percent, respectively. b) To obtain full-load currents for 265 and 277 V motors, decrease corresponding 220 - 240 V ratings by 13 and 17 percent, respectively. Quote from Power Conversion Equipment - UL 508C, May 3, 2002. Reproduced from UL 508 C, Power Conversion Equipment, 3rd edition (May 2, 2002) with permission of Underwriters Laboratories Inc.

CORRIENTE AVPLENA CARGA DE MOTOR

Embed Size (px)

DESCRIPTION

Tabla Corrientes de motor a plena carga en diferentes voltajes

Citation preview

  • 2010 CA08103002Z-EN www.eaton.com

    Singlephase

    Twophase

    Threephase

    Singlephase

    Twophase

    Threephase

    Singlephase

    Threephase

    Singlephase

    Twophase

    Threephase

    Singlephase

    Twophase

    Threephase

    1/10 3.0 1.5 1.0 1/8 3.8 1.9 1.2 1/6 4.4 2.2 1.4 1/4 5.8 2.9 1.8 1/3 7.2 3.6 2.3 1/2 9.8 4.0 4.4 4.9 2.0 2.2 3.2 1.3 2.5 1.0 1.1 2.0 0.8 0.93/4 13.8 4.8 6.4 6.9 2.4 3.2 4.5 1.8 3.5 1.2 1.6 2.8 1.0 1.31 16.0 6.4 8.4 8.0 3.2 4.2 5.1 2.3 4.0 1.6 2.1 3.2 1.3 1.71-1/2 20.0 9.0 12.0 10.0 4.5 6.0 6.4 3.3 5.0 2.3 3.0 4.0 1.8 2.42 24.0 11.8 13.6 12.0 5.9 6.8 7.7 4.3 6.0 3.0 3.4 4.8 2.4 2.73 34.0 16.6 19.2 17.0 8.3 9.6 10.9 6.1 8.5 4.2 4.8 6.8 3.3 3.95 56.0 26.4 30.4 28.0 13.2 15.2 17.9 9.7 14.0 6.6 7.6 11.2 5.3 6.17-1/2 80.0 38.0 44.0 40.0 19.0 22.0 27.0 14.0 21.0 9.0 11.0 16.0 8.0 9.010 100 48.0 56.0 50.0 24.0 28.0 33.0 18.0 26.0 12.0 14.0 20.0 10.0 11.015 135 72.0 84.0 68.0 36.0 42.0 44.0 27.0 34.0 18.0 21.0 27.0 14.0 17.020 94.0 108 88.0 47.0 54.0 56.0 34.0 44.0 23.0 27.0 35.0 19.0 22.025 118 136 110 59.0 68.0 70.0 44.0 55.0 29.0 34.0 44.0 24.0 27.030 138 160 136 69.0 80.0 87.0 51.0 68.0 35.0 40.0 54.0 28.0 32.040 180 208 176 90.0 104 112 66.0 88.0 45.0 52.0 70.0 36.0 41.050 226 260 216 113 130 139 83.0 108 56.0 65.0 86.0 45.0 52.060 133 154 103 67.0 77.0 53.0 62.075 166 192 128 83.0 96.0 66.0 77.0100 218 248 165 109 124 87.0 99.0125 312 208 135 156 108 125150 360 240 156 180 125 144200 480 320 208 240 167 192250 602 403 302 242300 482 361 289350 560 414 336400 636 477 382500 786 590 472a) To obtain full-load currents for 200 and 208 V motors, increase corresponding 220 - 240 V ratings by 15 and 10 percent, respectively.b) To obtain full-load currents for 265 and 277 V motors, decrease corresponding 220 - 240 V ratings by 13 and 17 percent, respectively.Quote from Power Conversion Equipment - UL 508C, May 3, 2002.Reproduced from UL 508 C, Power Conversion Equipment, 3rd edition (May 2, 2002) with permission of Underwriters Laboratories Inc.