Copy of PNC Profile - PNC Oil – Transformer and ... · Purification of Transformer Insulating Oils The following specifications describes the plants used by PNC Oil for the filtration

  • Upload
    others

  • View
    3

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Copy of PNC Profile - PNC Oil – Transformer and ... · Purification of Transformer Insulating Oils The following specifications describes the plants used by PNC Oil for the filtration

Tel: (010) 013 0263 / (016) 100 6116  Fax: 086 634 8801

email: [email protected] Website: www.pncoil.co.za

Page 2: Copy of PNC Profile - PNC Oil – Transformer and ... · Purification of Transformer Insulating Oils The following specifications describes the plants used by PNC Oil for the filtration

W W W . P N C O I L . C O . Z A

Oil Sampling

Transformer Services

Full Test (Water, kV, Acid & DGA) Normal Test (kV, Water & Acid) PCB Exact Count (ppm); Furanics Test; Tan Delta and interfacial tension as well as others

*ALL ANALYSIS OF SAMPLING DONE BY A 3rd PARTY INDEPENDENT LABORATORY

We specialize in the installation and commissioning of transformers up to 315MVA and also provide the following services:      Repairs on transformers such as oil leaks, tap changers,      bushing etc.      Rewind of transformers      Testing of transformers      Full commissioning tests      Cleaning of transformers      Spray painting of transformers      Purification of transformer oil (we attend to the purification      of the oil, either off-line or on-line)      On site regeneration of transformer oil      Supply and delivery of mini-subs      We also buy and sell transformers

Page 3: Copy of PNC Profile - PNC Oil – Transformer and ... · Purification of Transformer Insulating Oils The following specifications describes the plants used by PNC Oil for the filtration

W W W . P N C O I L . C O . Z A

Purification of Transformer Insulating Oils The following specifications describes the plants used by PNC Oil for the filtration of transformer insulating oil:

During the vacuum stage of the process all dissolved gasses are removed from the oil, leaving it clean, dry and gas free. Oxygen, as an accelerator of oxidation, is also removed.

The purifiers are designed for filtration of transformer oil in workshops, storage tanks, drums or directly in transformers. Purification of oil in transformers can be carried out off-load or on- load depending on customer's preference.

Water Removal:Water is removed by heating the oil passing it through coalesces inside a vacuum chamber. During this process water and oil are separated and clean dry insulating oil is returned to the transformer

Gas Removal:

Particulate Matter Removal:98% of all particles over 0.5 micrometer is removed Dielectric Strength:Improvement in dielectric strength, up to 70 kV, with new oil.

Switchgear ServicesOur services also include the following pertaining to switchgearService and repair of HT circuit breakers Retro fitting of HT circuit breakers The servicing and testing on all relays and CT's Cleaning and painting of substations Service of battery trip units We also buy and sell HT circuit breakers, vacuum breakers and gas breakers Installation and commissioning of HT circuit breakers

Other ServicesBuilding of overhead lines up to 132 kV Cable fault finding Cable joints & terminations Consulting Infrared scanning Transportation Assist in fire suppression systems

Page 4: Copy of PNC Profile - PNC Oil – Transformer and ... · Purification of Transformer Insulating Oils The following specifications describes the plants used by PNC Oil for the filtration

" I n C h r i s t J e s u s w e b e l i e v e "

PNC was established in 2009 and have, throughout the years, completed and maintained various successful projects. As a group of qualified andexperienced individuals the company has grown to become a competitor in the market of transformer maintenance as well as the servicing of

high voltage electrical equipment. Our quality service levels are underpinned by our expert management team and support staff.

We have more than 45 years' experience in transformer maintenance  and the servicing of high voltage electrical equipment. We have, more recently, changed our focus to not only include the above, but are also providing switchgear services and switchgear maintenance to our clients

and prospective clients.

 We are a proud level 3 BEE contributor. Our main objective is focusing on the skill development of our employees and support staff.

We strive to provide our clients with quality service and products, excellent working relationships and prompt feedback.

MORE ABOUT US

Company DetailsPhysical Address: GPS Co-ordinates: Postal Address: Tel: Fax: E-mail: Reg. no.: VAT no.: Website:

10 Bunsen Street, Heidelberg, 1438 26⁰30'57.03"S  28⁰21'28.08"E P.O. BOX 260, Heidelberg, 1438 010 013 0263 / 016 100 6116 086 634 8801 [email protected] 2017/221425/07 4580253518 www.pncoil.co.za

Emergency Details (after hours)Perry du Toit Managing Director Cell: 082 854 5586 E-mail: [email protected] Frans Grobler Sales Representative Cell.: 078 975 1022 E-mail: [email protected] Morne Nel Sales Representative Cell.: 083 698 2358 E-mail: [email protected] Marius Mans Sales Representative Cell.: 082 521 8794 E-mail: [email protected]

ReferencesROYAL SWAZI SUGAR  ZAMBEEF EDISON POWER ANGLO SISHEN ANGLO AMERICAN ANGLO PLATINUM BASE METALS EXXARO GROUP OF MINES RAND WATER SAMANCOR FERROCHROME TUBATSE HERNIC FERROCHROME ARCELOR MITTALIf any reference contact numbers are required, please do not hesitate to contact us.

Employing positive and productive  people that service the medium

voltage grid in the Southern African region"

VISION MISSION"We aim to become the

recognized market leader in our field of expertise, providing

 excellent service."