Conventional fire alarm system products 1 / 16 Address: 18A LANCHESTER WAY, ROYAL OAK INDUSTRIAL ESTATE, DAVENTRY, NORTHAMPTONSHIRE ENGLAND Zip Code: NN11 8PH Tel: 447624095053, Fax: 447624095053-803, Mobile: 447624094280 www.asenware.com Conventional fire alarm control panel AW-CFP2166 Introduction: 1. AW-CFP2166 series conventional fire alarm panel is designed based on EN54 part 2&4 standard. 2. It is modularized design, the panel can extend from 1 zone to 32 zones easily. 3. It has 2 level control mode by a lock 4. It has 24VDC and 5VDC power supply output. 5. It has FIRE and FAULT signal output. 6. It has 2 general sounders output. 7. Each zone has 1 circuit detectors input . 8. Each zone can be disable by a button. 9. It has RESET button to reset the panel. 10. It has SILENCE button to stop BUZZER and SOUNDERS. 11. It has EVACUATE button to start a manual fire alarm immediately. 12. It has battery low protection function, when battery voltage lower than 21VDC, battery will be cut off automatically until the mains power is on. 13. It has an optional GSM module for fire alarm by SMS . 14. It is economic, user-friendly and easy maintenance.

Conventional fire alarm control panel AW-CFP2166

  • Upload
    others

  • View
    80

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Conventional fire alarm control panel AW-CFP2166

Conventional fire alarm system products 1 / 16

Address: 18A LANCHESTER WAY, ROYAL OAK INDUSTRIAL ESTATE, DAVENTRY, NORTHAMPTONSHIRE ENGLAND Zip Code: NN11 8PH Tel: 447624095053, Fax: 447624095053-803, Mobile: 447624094280 www.asenware.com

Conventional fire alarm control panel

AW-CFP2166

Introduction: 1. AW-CFP2166 series conventional fire alarm panel is designed based on EN54 part 2&4

standard. 2. It is modularized design, the panel can extend from 1 zone to 32 zones easily. 3. It has 2 level control mode by a lock 4. It has 24VDC and 5VDC power supply output. 5. It has FIRE and FAULT signal output. 6. It has 2 general sounders output. 7. Each zone has 1 circuit detectors input . 8. Each zone can be disable by a button. 9. It has RESET button to reset the panel. 10. It has SILENCE button to stop BUZZER and SOUNDERS. 11. It has EVACUATE button to start a manual fire alarm immediately. 12. It has battery low protection function, when battery voltage lower than 21VDC, battery will

be cut off automatically until the mains power is on. 13. It has an optional GSM module for fire alarm by SMS . 14. It is economic, user-friendly and easy maintenance.

Page 2: Conventional fire alarm control panel AW-CFP2166

Conventional fire alarm system products 2 / 16

Address: 18A LANCHESTER WAY, ROYAL OAK INDUSTRIAL ESTATE, DAVENTRY, NORTHAMPTONSHIRE ENGLAND Zip Code: NN11 8PH Tel: 447624095053, Fax: 447624095053-803, Mobile: 447624094280 www.asenware.com

Parameters: ITEM 1Zone panel 2Zone panel 4-8 Zone panel 12-32 Zone

panel Model No. AW-CFP2166-01 AW-CFP2166-02 AW-CFP2166-04

-8 AW-CFP2166-12-

32 Power specification

Mains supply voltage 110VAC or 240VAC Internal power supply 27.2VDC

Total output current limited 500mA @ 240VAC

500mA @ 240VAC

3A @ 240VAC 3A @ 240VAC

Main supply monitor for fault Yes Battery protection for low voltage Yes Batteries (default configuration) 12V2AH*2

Detector circuit specification Number of circuit 1 2 4-16 4-32

Line fault monitor for open circuit Yes Line fault monitor for short circuit Yes

Line fault monitor for detector removal

Yes, if End of Line Monitor Unit fitted in place of End of Line Resistor

End of Line device 6.8k Ω,5% tolerance, 0.25W (colour code-blue,grey,red,gold) Detector continuity diodes Silicon 1N4001 or Schottky type (required if End of Line Monitor Unit fitted

to give Detector Removal Fault) Call point resistor value 470 to 680 Ω, 0.225 or 0.5 watt

Maximum number of smoke/heat detectors per zone

20 (based on a total detector current of 2mA, each detector consuming 100μA).Note: if End of Line Monitor Unit is fitted, for correct operation maxmum

voltage drop must not exceed 12 volts. Maximum number of manual call

points per zone No limit

Sounder circuit specification Number of general circuits 2 End of line resistor value 6.8k Ω,5% tolerance, 0.25W (colour code-blue,grey,red,gold)

Line fault monitor for open circuit Yes Line fault monitor for short circuit Yes

Outputs fused AT 400mA Maximum number of bells @ 20mA

of each sounder output 20

Fuses Battery fuse 1.5A F 20mm

Sounder outputs 500mA F 20mm Fire and fault output

Output type NC and NO relay

Page 3: Conventional fire alarm control panel AW-CFP2166

Conventional fire alarm system products 3 / 16

Address: 18A LANCHESTER WAY, ROYAL OAK INDUSTRIAL ESTATE, DAVENTRY, NORTHAMPTONSHIRE ENGLAND Zip Code: NN11 8PH Tel: 447624095053, Fax: 447624095053-803, Mobile: 447624094280 www.asenware.com

Maximum current 100mA Connection block

Largest acceptable conductor size 2.5mm2 Smallest acceptable conductor size 0.75mm2

Size and weight Dimensions(mm) 272*200*70mm 320*231*90mm 395X502X124 362X565X124

Weight (without batteries) 4kg 5kg 7kg 8kg Weight (with batteries) 5.8kg 6.8kg 9.6kg 12.5kg

Conventional photoelectric smoke detector

Model No.:AW-CSD311

Item Parameters Operating Voltage Range: 9 to 32 VDC Volts Non-polarized Standby Current: ≤100µA @ 24 VDC Maximum Alarm Current (LED on: ) ≤55mA @ 24 VDC Operating Humidity Range: 10% to 93% Relative Humidity, Non-condensing Operating Temperature Range: 14°F to 120°F (-10°C to 49°C) Adjustable Sensitivity: 1-2.5%/FT Height: 2.2˝ (55 mm) installed in Base Diameter: 4.0˝ (103 mm) Weight: 5.5 oz. (155 g) Conventional fix temperature heat detector

Page 4: Conventional fire alarm control panel AW-CFP2166

Conventional fire alarm system products 4 / 16

Address: 18A LANCHESTER WAY, ROYAL OAK INDUSTRIAL ESTATE, DAVENTRY, NORTHAMPTONSHIRE ENGLAND Zip Code: NN11 8PH Tel: 447624095053, Fax: 447624095053-803, Mobile: 447624094280 www.asenware.com

Model No.: AW-CTD805

Item Parameters Height: 2.2˝ (55 mm) installed in Base Diameter: 4.0˝ (103 mm) Weight: 5.5 oz. (155 g) Installation Temperatures: 14°F to 122°F (-10°C to50°C) Operating Humidity Range: 10% to 93% Relative Humidity Non-condensing Operating Voltage Range: 9 to 28VDC Volts Non-polarized Standby Current: 40µA @ 24 VDC Maximum Alarm Current (LED on: ) ≤30mA @ 24 VDC Fixed Temperature Rating: 135°F (57°C) Conventional smoke and heat combined detector

Model No.: AW-CSH202

Item Parameters Operating Voltage Range: 9 to 28VDC Volts Non-polarized Standby Current: ≤60µA @ 24 VDC

Page 5: Conventional fire alarm control panel AW-CFP2166

Conventional fire alarm system products 5 / 16

Address: 18A LANCHESTER WAY, ROYAL OAK INDUSTRIAL ESTATE, DAVENTRY, NORTHAMPTONSHIRE ENGLAND Zip Code: NN11 8PH Tel: 447624095053, Fax: 447624095053-803, Mobile: 447624094280 www.asenware.com

Maximum Alarm Current (LED on: ) ≤30mA @ 24 VDC Operating Humidity Range: 10% to 93% Relative Humidity, Non-condensing Operating Temperature Range: 14°F to 120°F (-10°C to 49°C) Smoke Sensitivity: 1.06±.26%FT. Fixed Temperature Rating: 135°F (57°C) Rate of Rise Detection: Responds to greater than 15°F/min Height: 2.2˝ (55 mm) installed in Base Diameter: 4.0˝ (103 mm) Weight: 5.5 oz. (155 g) Entrance LED

Model No.:AW-EL2166

Manual Call Point Model No. Photo Parameters AW-CMC2166-1 (Break glass)

Working voltage:

220VAC/50Hz or 24VDC

Maximum current:

Page 6: Conventional fire alarm control panel AW-CFP2166

Conventional fire alarm system products 6 / 16

Address: 18A LANCHESTER WAY, ROYAL OAK INDUSTRIAL ESTATE, DAVENTRY, NORTHAMPTONSHIRE ENGLAND Zip Code: NN11 8PH Tel: 447624095053, Fax: 447624095053-803, Mobile: 447624094280 www.asenware.com

AW-CMC2166-5

5A (220VAC/50Hz) or

8A(24VDC)

Contactor resistance: ≤0.1Ω

Working temperature:

-10~+50 ℃

Relative humidity: max ≤93±2%

Bell AW-CBL2166-A

(with iron base)

Bell Base

Model No. Diameter Work voltage

Work

current @

24VDC

Volume(dB)

AW-CBL2166-A-4 4” (100mm) DC6V

DC12V

DC24V

AC110V

AC230V

25 mA

85

AW-CBL2166-A-6 6”(150mm) 95

AW-CBL2166-A-8 8”(200mm) 97

AW-CBL2166-A-10 10”(250mm) 100

Note: default is including the base.

Bell AW-CBL2166-B

Page 7: Conventional fire alarm control panel AW-CFP2166

Conventional fire alarm system products 7 / 16

Address: 18A LANCHESTER WAY, ROYAL OAK INDUSTRIAL ESTATE, DAVENTRY, NORTHAMPTONSHIRE ENGLAND Zip Code: NN11 8PH Tel: 447624095053, Fax: 447624095053-803, Mobile: 447624094280 www.asenware.com

(with plastic base)

Model No. Diameter Work voltage Current @ 220VAC Power (VA) AW-CBL2166-B-2 2” (55mm)

110VAC 230VAC

50 mA 8 AW-CBL2166-B-3 3” (75mm) 80 mA 10 AW-CBL2166-B-4 4” (100mm) 97 mA 22 AW-CBL2166-B-6 6” (150mm) 100 mA 25 AW-CBL2166-B-8 8” (200mm) 105 mA 25

AW-CBL2166-B-10 10” (250mm) 125 mA 30 AW-CBL2166-B-12 12” (300mm) 150 mA 35

Strobe Horn/Hooter

AW-CSS2166-2 Parameters: AW-CSS2166-2 Work Voltage DC20V-DC30V Work Current (average) 95mA

Page 8: Conventional fire alarm control panel AW-CFP2166

Conventional fire alarm system products 8 / 16

Address: 18A LANCHESTER WAY, ROYAL OAK INDUSTRIAL ESTATE, DAVENTRY, NORTHAMPTONSHIRE ENGLAND Zip Code: NN11 8PH Tel: 447624095053, Fax: 447624095053-803, Mobile: 447624094280 www.asenware.com

Flash intensity ≥1.2WS Flash cycle <2.0s Flasher life ≥30000times

Max alarm volume ≥100dB

Alarm voice A: pokice car B: Fire Truck ( default) C: Ambulance

Size 160*128*54mm 134*115*48mm Flash light

Model No.: AW-CBL2166 Item Parameters Color red (default),green, yellow,blue

Work voltage 12VDC, 24VDC(default) Light head diameter 65mm

Beam smoke detector

AW-BK801

Page 9: Conventional fire alarm control panel AW-CFP2166

Conventional fire alarm system products 9 / 16

Address: 18A LANCHESTER WAY, ROYAL OAK INDUSTRIAL ESTATE, DAVENTRY, NORTHAMPTONSHIRE ENGLAND Zip Code: NN11 8PH Tel: 447624095053, Fax: 447624095053-803, Mobile: 447624094280 www.asenware.com

Brief introduction AW-BK801 Line Beam Smoke Fire Detector (hereinafter referred to as detector) is a long-interval reflection line infrared beam smoke detector which must be used together with a reflector. In case of smoke on the light path of the detector, the signal arriving at the receiver is reduced; when the light reduction rate reaches the preset threshold, the detector will produce the alarm signal; when the light beam is completely blocked, the detector will produce the fault signal to prevent the false alarm caused by non-fire blockage. Thanks to the built-in uniprocessor with excellent performance, the detector has a powerful analysis and judgment capability and can automatically complete the systematic debug, the compensation for external environmental parameter variation, and the judgment of fire alarm and fault, and also can give status indication through the indicator lamp and the signal output terminal. The detector adopting a brand-new and reasonable structural design is sensitive in adjustment, correct in positioning, easy in installation, and simple and convenient in debugging method. The detector contains a group of alarm passive normally open contacts and a group of fault alarm normally closed contacts as well as 4-20mA standard signal output to be conveniently connected with the fire alarm system and DCS system of plants of fire fighting equipment. Characters:

Wide operating voltage range and wide protective area※ Self※ -diagnosis capability, monitoring of faults in the detector Field setup of two levels of sensitivity※ Built※ -in microprocessor, intelligentized fire alarm and fault judgment Fire alarm and fault passive output contacts and standard 4※ -20mA standard power supply

output Smart design of the detection ligh※ t path, high antijamming performance, seal protocol,

corrosion protection and waterproof performance Integration of the transmitting part and the receiving part, simple and convenient※

installation, good light path collimation Automatic compensation fun※ ction, and automatic compensation for factors of received signal

reduction such as dust pollution, position deflection, ageing of the transmitting tube, etc. to some extent

Automatic calibration function to enable a single person to complete debug within※ a short time, simple operation, easy integration of the transmitting part and the receiving part, simple and convenient installation, good light path collimation Technical Parameters

Operating Voltage※ : DC16V~DC32V Adjusting Angle※ :-6 DEG ~+6 DEG ※ External Dimensions: 206mm×95mm×95 mm (length×width×thickness) Material and Color of the Casing※ :ABS, white Weight※ :450g Light path Length※ :8m~100m Operating Current※ :monitoring current ≤12 mA,alarm current ≤22mA,debugging current

Page 10: Conventional fire alarm control panel AW-CFP2166

Conventional fire alarm system products 10 / 16

Address: 18A LANCHESTER WAY, ROYAL OAK INDUSTRIAL ESTATE, DAVENTRY, NORTHAMPTONSHIRE ENGLAND Zip Code: NN11 8PH Tel: 447624095053, Fax: 447624095053-803, Mobile: 447624094280 www.asenware.com

≤20mA Sensitivity L※ evel:Fire level of sensitivity—high sensitivity???second level of

sensitivity—common sensitivity Fire alarm, fault contact output: fire alarm relay※ —rating of contacts 24V/1A, normally

open during normality and normally closed in case of fire alarm Fault relay—rating of contacts 24V/1A, normally closed during normality and normally open in case of fault Indication of status of the detector: 1) Debugging Status: the green, red and yellow indicator lamps light up or flash in a specific mode, see Debug in the download data for detailed information. 2) Normal monitoring status: the green indicator lamp flashes periodically. 3) Fire Alarm: the red indicator lamp keeps lighting;the yellow indicator lamp blacks out. The fire alarm should be cancelled through being powered again. 4) Fault: the yellow indicator lamp keeps lighting; in case of fault recovery, the fault signal of the detector is automatically cancelled by the detector. 5) If the light path is completely blocked, the detector reports a fault and the yellow indicator lamp lights up.

Operating Environment※ :temperature -10 ~+50 relative humidity ≤95℃ ℃ % without condensation

Protective Area※ :the maximal protective area of the detector 14×100=1400 ㎡ Pitch of mounting holes ※ :Burying installation size--158mm pitch of the fixed holes for

open installation--79 mm×96 mm Application Places

Warehouses, large※ -scale storage areas, shopping plazas, body-building centers, gymnasiums, exhibition halls, hotel halls, printing works, costume plants, museums, prisons, etc, as well as space with light smoke dust. UV flame detector

AW-FD602-UV

Page 11: Conventional fire alarm control panel AW-CFP2166

Conventional fire alarm system products 11 / 16

Address: 18A LANCHESTER WAY, ROYAL OAK INDUSTRIAL ESTATE, DAVENTRY, NORTHAMPTONSHIRE ENGLAND Zip Code: NN11 8PH Tel: 447624095053, Fax: 447624095053-803, Mobile: 447624094280 www.asenware.com

SPECIFICATIONS Operating Voltage Range: 12 to 30 VDC Volts Standby Current: ≤10 mA @ 24 VDC Alarm Current ≤30 mA @ 24 VDC Spectrum: 180~290nm Detection Angle: 110 degree Detection Sensitivity: Grade I, 25m@flame (Container 33cmX33cm,Height 5cm with 2Kg ethanol ) Relay Contact Load: 1A@DC24V Normal Status: LED blinking in 5 seconds interval Alarm Status: LED lit steady Protection rating: IP 32 Operating Humidity Range: 10% to 93% Relative Humidity, Non-condensing Operating Temperature Range: -10°C to 50°C (14°F to 122°F) Height: 1.8˝ (45 mm) installed in Base Diameter: 4.0˝ (103 mm) Weight: 5.4 oz. (153g)

FIGURE1 Vertical Detection Angular Sensitivity(Directivity)

FIGURE2 Horizontal Detection Angular Sensitivity(Directivity)

ANODECATHODE

90

60 60

30 30

0

90

100%

80

60

40

20

VERTICAL VIEWING

90

60 60

30 30

0

90

100%

80

60

40

20

ANODECATHODE HORIZONTAL VIEWING

VERTICAL VIEWING

HORIZONTAL VIEWING

UV EMISSION POINT

VERTICAL VIEWING

HORIZONTAL VIEWING

UV EMISSION POINT

Page 12: Conventional fire alarm control panel AW-CFP2166

Conventional fire alarm system products 12 / 16

Address: 18A LANCHESTER WAY, ROYAL OAK INDUSTRIAL ESTATE, DAVENTRY, NORTHAMPTONSHIRE ENGLAND Zip Code: NN11 8PH Tel: 447624095053, Fax: 447624095053-803, Mobile: 447624094280 www.asenware.com

Automatic fire extinguisher control panel

Model No.: AW-GEC2158

Parameters:

ITEM ELECTRICAL RATING COMMENT

Mains supply 90 to 270VAC, 50Hz/60Hz(100 Watts maximum)

Mains supply fuse 3 Amp ( F3A L250V) Replace only with similar type

Power supply rating 3 Amps total including battery charge 28V +/- 2V

Maximum ripple current 200 millivolts

Battery type Two 12 Volt sealed lead acid in series.

7Ah maximum

Battery charge voltage 27.6VDC nominal Battery charge current 0.7A maximum Battery fuse 20mm, 3.15 glass Current draw in mains fail condition

0.095 Amps With buzzer sounding

Current draw in second stage alarm

0.235A Two zones in fire(470 ohm in circuit)

Current draw in post discharge condition

0.310A solenoid outputs active

Maximum current draw from batteries

3Amps With main power disconnected

R0V output Fused at 500Ma with electronic fuse

Page 13: Conventional fire alarm control panel AW-CFP2166

Conventional fire alarm system products 13 / 16

Address: 18A LANCHESTER WAY, ROYAL OAK INDUSTRIAL ESTATE, DAVENTRY, NORTHAMPTONSHIRE ENGLAND Zip Code: NN11 8PH Tel: 447624095053, Fax: 447624095053-803, Mobile: 447624094280 www.asenware.com

Sounder outputs 21 to 28V DC Fused at 500mA with electronic fuse

1.6Amp total load over all circuits

Fault relay contact rating 5 to 30VDC 1A Amp maximum for each

Volt free changeover contact

Fire relay contact rating 5 to 30VDC 1A Amp maximum for each

Volt free changeover contact

Local fire relay contact rating

5 to 30VDC 1A Amp maximum for each

Volt free changeover contact

First stage contact rating 5 to 30VDC 1A Amp maximum for each

Volt free changeover contact

Second stage contact rating 5 to 30VDC 1A Amp maximum for each

Volt free changeover contact

Extract contact rating 5 to 30VDC 1A Amp maximum for each

Volt free changeover contact

Zone quiescent current 0mA minimum, 2mA maximum

Terminal capacity 0.5mm2 to 2.5mm2 solid or stranded wire

Number of detectors per zone

Dependent on type

Number of sounders per circuit

Dependent on type and current consumption

Detection circuit end of line 6K8±5% 1/2 Watt resistor

Monitored input end of line 6K8±5% 1/2 Watt resistor

Sounder circuit end of line 10K±5% 1/2 Watt resistor

Extinguishant output end of line

1N4004 Diode

No. of detection circuits Four 21 to 28V DC

No. of sounder circuits Three 21 to 28V DC 2X first stage, 1 X second stage

Extinguishant release output 21V to 28V DC. Maximum load 1 Amp

Extinguishant release delay Adjustable 0 to 75 seconds 5 second steps

SIL, AL, FLT, RST inputs Switched –ve, min resistance 0 ohms, max 470 ohms

Zone normal threshold (Allowable EOL)

10K ohms to 2K ohms Use 6K8 end of line resistor

Page 14: Conventional fire alarm control panel AW-CFP2166

Conventional fire alarm system products 14 / 16

Address: 18A LANCHESTER WAY, ROYAL OAK INDUSTRIAL ESTATE, DAVENTRY, NORTHAMPTONSHIRE ENGLAND Zip Code: NN11 8PH Tel: 447624095053, Fax: 447624095053-803, Mobile: 447624094280 www.asenware.com

Detector alarm threshold 1K ohms to 390 ohms

Call point alarm threshold 370 ohms to 150 ohms

Short circuit threshold 130 ohms to 0 ohms

Head removal condition 15.5 to 17.5 volts+/- 5%

Cabling FP200 or equivalent Metal cable glands must be used.

Monitored inputs normal threshold 10K ohms to 2K ohms (Allowable EOL) Monitored inputs alarm threshold

2K ohms to 150 ohms+/-5%

Monitored inputs Short circuit threshold

140 ohms to 0 ohms+/-5%

Status unit/Ancillary board connection

Two wire RS485 connection with electronic fuse.

Max. of 16 units-RS485 data cable

Status unit power output 21 to 28V DC, Fused at 500mA with electronic fuse.

300 milliamp maximum load

Manual Release Station

Model No.: AW-MRS2158

The Manual release is connected with Fire fighting panel. There are three buttons on the station, one is START button, and another one is STOP button. When the START button is pressed, you can press RESTORE button to restore the start button. Operating voltage: DC24V

Page 15: Conventional fire alarm control panel AW-CFP2166

Conventional fire alarm system products 15 / 16

Address: 18A LANCHESTER WAY, ROYAL OAK INDUSTRIAL ESTATE, DAVENTRY, NORTHAMPTONSHIRE ENGLAND Zip Code: NN11 8PH Tel: 447624095053, Fax: 447624095053-803, Mobile: 447624094280 www.asenware.com

Maintance Switch

MODEL NO.: AW-MS2158

Specification: This MAINTENANCE panel is a key switch, which disconnects actuation circuits in the system to prevent accidental discharge during maintenance operations. Two “LEDS” indicate “SYSTEM ARMED” and “SYSTEM INACTIVE”. When the key is inserted and turned towards “SYSTEM INACTIVE”, the red LED illuminates and the green LED indicating “SYSTEM ARMED” turns off. The key can only be removed in the “SYSTEM ARMED” position. This panel is also available with the key removable in both the “ARMED” and the “INACTIVE” positions. The information is silk-screened on a two-gang stainless plate. Switch rated at 5A 250VAC, the DC rating is 5A up to 30VDC. LEDS rated at 10mA each for a total current draw of 20mA.

Operating voltage: DC24V

WIRING DIAGRAM

Page 16: Conventional fire alarm control panel AW-CFP2166

Conventional fire alarm system products 16 / 16

Address: 18A LANCHESTER WAY, ROYAL OAK INDUSTRIAL ESTATE, DAVENTRY, NORTHAMPTONSHIRE ENGLAND Zip Code: NN11 8PH Tel: 447624095053, Fax: 447624095053-803, Mobile: 447624094280 www.asenware.com

Gas Release Warning Signage

MODEL NO.: AW-GRS2158

Specification:

Operating Voltage: DC24V/AC24V Non-polarized

Working Current: ≤70mA @ 24 VDC

Flash Period: 1.2-1.5 Sec.