19
Catalogue Controlled Rate Freezers Benchtop Incubators Alarms & Monitoring Sample Tracking

Controlled Rate Freezers Benchtop Incubators Alarms & … · 2018-11-26 · Controlled Rate Freezers Benchtop Incubators Alarms & Monitoring Sample Tracking. Planer plc ... we have

  • Upload
    others

  • View
    3

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Controlled Rate Freezers Benchtop Incubators Alarms & … · 2018-11-26 · Controlled Rate Freezers Benchtop Incubators Alarms & Monitoring Sample Tracking. Planer plc ... we have

Catalogue

Controlled Rate Freezers

Benchtop Incubators

Alarms & Monitoring

Sample Tracking

Page 2: Controlled Rate Freezers Benchtop Incubators Alarms & … · 2018-11-26 · Controlled Rate Freezers Benchtop Incubators Alarms & Monitoring Sample Tracking. Planer plc ... we have

Planer plc110 Windmill Road, Sunbury-On-ThamesMiddlesex TW16 7HD, United Kingdom

Tel: +44 (0)1932 755 000 Fax: +44 (0)1932 755 001

[email protected]

Specifications may change without notice, third party trademarks acknowledged.

© 2016 Planer plc

Track your samples, with off-the-shelf intuitive software, that is quick and easy to set up.

Index

FREEZING

INCUBATING

MONITORING

STORING

A range of programmable freezers and peripherals, ideal whether you need to freeze straws, vials or blood bags.

For both human and animal IVF applications, the Planer benchtop incubators provides an ideal in-vitro environment.

Keep your laboratory safe and compliant with our range of alarms and monitoring equipment that is quick and easy to set up.

For over 40 years, we have been helping hospitals, research laboratories, pharmaceutical companies and the IVF industry with the safe storage and preservation of medical and biological specimens.

We work closely with scientists and the medical profession to understand their requirements and supply high quality, reliable equipment that conforms to ISO and Medical Device standards and, where appropriate, assist with compliance including 21 CFR Pt 11.

FREEZING Planer can significantly increase the viability of frozen cells and tissues in a reproducible, documented and reliable controlled rate freezer.

INCUBATING Our benchtop incubators provide a superior in vitro environment for cells, combining rapid recovery following lid opening, low gas consumption and a modest footprint.

MONITORING Protecting the irreplaceable, Planer monitoring systems use an array of sensor types to ensure sample, laboratory and personal safety. STORING User definable software platform Pro-Curo ensures that no sample will ever be lost or misplaced.

SUPPORT With nearly half a century of experience servicing leading laboratories and organisations around the world plus a global network of 80 distributors, you and your samples are in safe hands.

To find out more, please contact us on +(44) 1932 755 000 or email [email protected]

Helping scientists and medical professionals look after cells

Page 3: Controlled Rate Freezers Benchtop Incubators Alarms & … · 2018-11-26 · Controlled Rate Freezers Benchtop Incubators Alarms & Monitoring Sample Tracking. Planer plc ... we have

Controlled temperature reduction prevents the formation of lethal intracellular ice: the Kryo 360 significantly improves viability yield post-thaw and is ideal for small sample sizes.

Accurate control, safety features and sample history data logging make these freezers world-class leaders.

The Kyro 360 range is simple to programme and operate, with the controller displaying demand, sample and chamber temperatures.

Whether you wish to freeze up to 60 straws or up to 60 ampoules, the freezers produce repeatable, consistent results with easy data recording thanks to the integral printer and PC comms port.

Batch freezing is possible using our DeltaT software. Large sample numbers can be deposited in different machines with the subsequent freezing profile for all samples being displayed on the same graph.

The system controller offers password-controlled access on multiple user levels, with users being able to customize up to 10 profiles.

Additional safety features have been fitted to help protect against power and PC failure.

– user definable freezing profiles

– inbuilt alarms and user notifications

protection, reporting and temperature graphs

chamber size options accommodate straws or vials

freezing methods

FREEZING

Want to optimise freezing profiles? [email protected]

Kryo 360

Compact controlled rate freezers

SYSTEM SPECIFICATION

Range +40 °C to -180 °C

Heating rate 0.01 °C/min to 10 °C/min

Cooling rate -0.01 °C/min to -50 °C/min

Controller accuracy ±0.3 °C measured on a hold at 0 °C

Storage temperature -10 °C to +50 °C

Storage humidity 5 % to 95 % relative humidity non-condensing

Operating temperature 5 °C to 40 °C

Operating humidity 5 % to 90 % relative humidity non-condensing

CONTROLLER SPECIFICATION

Dimensions 80 mm high x 220 mm wide x 350 mm deep

Weight (approx.) 2.6 kg

Display 240 x 64 LCD with CCFL backlight

Printer 320/640 dot thermal printer

Keypad 20 key membrane keypad

Programmable Cooling Rate Range -0.01 °C/min to -99.9 °C/min

Number of profiles 10

Steps per profile 32

Number of stored runs 10

CHAMBER SPECIFICATION

Weight (kg) 14.4(1.7 L chamber) or 14.7(3.3 L chamber)

Chamber dimensions 1.7 L chamber:

Internal 200 mm x 150 mm diameter External 450 mm high x 300 mm wide x 420 mm deep 3.3 L chamber: Internal 400 mm x 150 mm diameter External 450 mm high x 300 mm wide x 420 mm deep

0.25 ml straws 60 (1.7 L and 3.3 L chamber)

0.5 ml straws 45 (1.7 L and 3.3 L chamber)

2 ml vials 30 (1.7 L chamber) or 60 (3.3 L chamber)

Power requirements (including MRV Control-ler)

115V~ 50/60Hz 600VA / 230V~ 50/60Hz 600VA

RECOMMENDATION OF ADDITIONAL EQUIPMENT

5 psi System System Pump - LNP4-C

System Dewar - MVLAB 30

22 psi System System Cylinder - MVEUROCYL230SB

Phase Separator - MVPHASE

22 psi System (alternative) Vacuum Jacketed Pipe Work System

Phase Separator - MVPHASE

Kryo 360

TECHNICAL SPECIFICATION

Ai008V1

Compact controlled rate freezer

Page 4: Controlled Rate Freezers Benchtop Incubators Alarms & … · 2018-11-26 · Controlled Rate Freezers Benchtop Incubators Alarms & Monitoring Sample Tracking. Planer plc ... we have

A gold standard in the cryopreservation of bone marrow, cord blood and cells, the Kryo 560 is the tool of choice to ensure the best possible clinical outcome.

Whether you wish to freeze 2,900 straws or 48 PALL bags, the Kryo 560 provides a reliable, robust solution.

This top opening programmable freezer is simple to programme and operate, but flexible enough to offer multiple protocols.

Batch freezing is possible using our DeltaT software. Large sample numbers can be deposited in different machines with the subsequent freezing profile for all samples being displayed on the same graph.

Information is displayed and can be printed via the integral printer.

Security and safety is of paramount importance. There is password controlled multiple level user access, plus safety features to protect against power and PC failure.

straws, vials or blood bags

and proven Medical Device

password protection, reporting and temperature graphs

multiple chambers via one interface (batch freezing)

freezing methods

Want to optimise freezing profiles? [email protected]

Kryo 560

FREEZING

Medium sized controlled rate freezers

SYSTEM SPECIFICATION

Range +30oC to -180oC

Heating rate 0.01oC/min to 10oC/min

Cooling rate -0.01oC/min to -50oC/min

Controller accuracy ±(0.3 + 0.005 x TM)o C (where TM is the magnitude of the tem-perature)

Storage temperature -10 °C to +50 °C

Storage humidity 5 % to 95 % relative humidity non-condensing

Operating temperature 5 °C to 40 °C

Operating humidity 5 % to 90 % relative humidity non-condensing

CONTROLLER SPECIFICATION

Dimensions 80 mm high x 220 mm wide x 350 mm deep

Weight (approx.) 2.6 kg

Display 240 x 64 LCD with CCFL backlight

Printer 320/640 dot thermal printer

Keypad 20 key membrane keypad

Programmable Cooling Rate Range -0.01 °C/min to -99.9 °C/min

Number of profiles 10

Steps per profile 32

Number of stored runs 5

CHAMBER SPECIFICATION

Weight (kg) (approx) 23 kg

Capacity 16 litres

Chamber dimensions 350mm high x 230mm wide x 230mm deep

0.25 ml straws 2904 on canes or 456 on racks

0.5 ml straws 968 on canes or 456 on racks

Vials 784 x 1.0ml - 2.0ml or 244 x 5.0ml

50ml blood bags 22

250ml - 500ml blood bags 11

PALL Bags 22

Power requirements (including MRV Controller) 115V~ 50/60Hz 1500VA / 230V~ 50/60Hz 1500VA

RECOMMENDATION OF ADDITIONAL EQUIPMENT

5 psi System System Pump - LNP4-C

System Dewar - MVLAB 30 or GDPB35

22 psi System System Cylinder - MVEUROCYL230SB

Phase Separator - MVPHASE

22 psi System (alternative) Vacuum Jacketed Pipe Work System

Kryo 560

TECHNICAL SPECIFICATION

Ai009V1

Medium sized controlled rate freezer

Page 5: Controlled Rate Freezers Benchtop Incubators Alarms & … · 2018-11-26 · Controlled Rate Freezers Benchtop Incubators Alarms & Monitoring Sample Tracking. Planer plc ... we have

Sophisticated temperature control and simple operation – the Kryo750 is perfect for ensuring viable preservation of high volume valuable biological cells and tissues.

This controlled rate freezer is designed for freezing of bigger volumes of samples in bags, vials and straws. It has a simple 2 button operation to prevent the user accidently running the wrong protocols. By using our PC software, DeltaT, enables password protected multiple protocols, online data-viewing, capture and storing for validation.

Batch freezing is possible using our DeltaT software. Large sample numbers can be deposited in different machines with the subsequent freezing profile for all samples being displayed on the same graph.

A forced laminar flow cooling system ensures efficient, even cooling.The machine has top or front opening for easy loading.

The heated door seals prevent the lid freezing shut at cryogenic temperatures. Protocol stage “trigger on sample”, or chamber temperature, or time.

The inner chamber is removable for sterilisation. The 750 has a Comms port – for PC connection and has flexible and fast cooling rates.

button control

top loading options

user definable freezing profiles

multiple chambers via one interface (batch freezing)

Want to optimise freezing profiles? [email protected]

Kryo 750

FREEZING

TECHNICAL SPECIFICATIONS

Dimensions – Front Loading

External Internal

Height 55cm 26cm

Width 79 cm 46.5 cm

Depth 48cm 25cm

Dimensions – Top Loading

External Internal

Height 48cm 25cm

Width 79 cm 44.5 cm

Depth 55cm 26cm

Weight 45 kg (shipping weight inc. Packaging) approx.

2 ml vials 1452 on canes or 784 in baskets

Straws 5808 x 0.25ml (on canes), 2420 x 0.5ml (on canes) or 836 x 0.25ml-0.5ml (on racks)

PALL bloodbags 96

250-1000 ml blood bags

20

Circulation Horizontal laminar flow

Temperature range +100.0 °C to -160 °C

Cooling medium Liquid Nitrogen 22 ±2 psi

Heater 1000W

Sensors: Control and sample

4-wire Platinum resistance thermometer. Sensors are linearised in software to international standards that utilise a 4096-point lookup table based on BS1904:1984 Table 1. Calibration facility provided.

Medium sized controlled rate freezer

Accuracy ±0.5 °C at a hold at 0 °C (dynamic accuracy depends on actual programme, e.g. Rate of change of temperature)

Heating rates 0.01 °C/min to 10 °C/min

Cooling rates -0.01 °C/min to -10 °C/min

Programmable cool-ing rate range

-0.01 °C/min to -99.9 °C/min

Operating positions Vertical or horizontal

Thermal cutout 120 °C cutout

Power Requirements 103 - 126VAC 50/60Hz 1200VA (max.) (470VA freezing only, with seal and bearing heaters operating). The freezer may be damaged by voltage surges in excess of 15 % above nominal.

Chart sensitivity 16.7 mV/°C. Nominal impedance > 10K

Recorder Scaling 0V = -200 °C, +5V = +100 °C

Standards Designed to comply with BSEN 61010, CSA22.2No.125-M1984, CSA22.2No.151- M1986, EN50082-2, EN50081-2

Storage temperature -10 °C to +70 °C

Storage humidity Up to 95 % non-condensing

Operating tempera-ture

5 °C to 40 °C

Operating humidity Less than 90 % non-con-densing

RECOMMENDATION OF ADDITIONAL EQUIPMENT

22 psi System System Cylinder - MVEURO-CYL230SB Phase Separator - MVPHASE

22 psi System (alternative)

Vacuum Jacketed Pipe Work System Phase Separator - MVPHASE

Kryo 750

TECHNICAL SPECIFICATION

Ai010V1

Medium sized controlled rate freezer

Page 6: Controlled Rate Freezers Benchtop Incubators Alarms & … · 2018-11-26 · Controlled Rate Freezers Benchtop Incubators Alarms & Monitoring Sample Tracking. Planer plc ... we have

Share what leading pharmaceutical companies know with the increased yield provided by the Kryo 1060.

This top opening stainless steel freezer is ideal for precise freezing of samples in high volumes, such as volume cell line or vaccine storage.

Even and accurate temperature control, in all phases of the protocol, are possible due to the unique forced laminar flow pattern of the coolant and cryogenic insulation.

The -100 °C end temperature ensures sample integrity during transfer to storage, whilst the high capacity liquid nitrogen cylinder offers a large cooling reservoir with an extended hold time at the protocol end temperature.

Batch freezing is possible using our DeltaT software. Large sample numbers can be deposited in different machines with the subsequent freezing profile for all samples being displayed on the same graph.

increases for vaccines, cells and tissues

to 8000 ampoules

control, ‘per run’ reporting and real time alarms

user definable freezing profiles

Want to optimise freezing profiles? [email protected]

Kryo 1060

FREEZING

Large controlled rate freezer

TECHNICAL SPECIFICATION

TECHNICAL SPECIFICATIONS

Kryo 1060 180:

Dimensions External Internal

Height 112 cm 64 cm

Width 86cm 1x50cm

Depth 116cm 50cm

Weight 211 kg (shipping weight inc. Packaging) approx.

Capacity 4000 x 2 ml vials

Kryo 1060 380:

Dimensions External Internal

Height 112 cm 64 cm

Width 132 cm 100 cm

Depth 116cm 50cm

Weight 423 kg (shipping weight inc. Packaging) approx.

Capacity 8000 x 2 ml ampoules

Circulation Horizontal laminar flow

Temperature range +40 oC to -100 oC. Warning! The freezer is fitted with a manually-resettable thermal cut-out to prevent over heating. This will operate if the chamber is programmed to run above +40 oC and will require a Service Engineer to reset it.

Cooling medium Liquid Nitrogen 22 -30 psi

Heater 1700 W

Accuracy ±0.5 °C at a hold at 0 °C (dynamic accuracy depends on actual programme, e.g. Rate of change of temperature)

Heating rates 0.01 °C/min to 1 °C/min

Cooling rates -0.01 °C/min to -5 °C/min

Power Requirements 230V~ 50/60Hz, 16A (max.) The freezer may be damaged by voltage surges in excess of 15% above nominal.

Standards Complies with 89/336/EEC EMC Directive as amended by 93/68/EEC and 73/23/EEC Low Voltage Equipment Directive as amended by 93/68/EEC

Storage temperature -10 °C to +60 °C

Storage humidity Up to 95 % non-condensing

Operating tempera-ture

+5 °C to 40 °C

Operating humidity Less than 90 % non-con-densing

RECOMMENDATION OF ADDITIONAL EQUIPMENT:

22 psi System System Cylinder - MVEUROCYL230SB Phase Separator - MVPHASE

22 psi System (alter-native)

Vacuum Jacketed Pipe Work System Phase Separator - MVPHASE

Kryo 1060

Ai011V1

Large controlled rate freezer

Capacity data for straws, vials and blood bags available on request.

Page 7: Controlled Rate Freezers Benchtop Incubators Alarms & … · 2018-11-26 · Controlled Rate Freezers Benchtop Incubators Alarms & Monitoring Sample Tracking. Planer plc ... we have

Deploy one profile to several freezers with our DeltaT v7 software.

Each freezing run produces a detailed, date and time stamped summary, which can automatically be stored to a secure location over a local area network.

Password protection and tamper proof files helps compliance with 21 CFR Part 11.

Profiles can be created with up to 32 different stages (heat / cool / hold) combined with real time updates of both sample and chamber sensor readings.

Email notifications during the freezing run, as well as the audible alarm of the freezer, alert users of any significant deviations from the selected profile.

updates during freezing run

one instance of DeltaT

stages can be created

proof files

DeltaT Software

FREEZING

Freezer control with batch option DeltaT v7

DeltaT v7

Create profiles yes

Run Profiles yes

View kryofiles yes

Print kryofiles yes

Export kryofiles yes

Calibration yes

Run qualification yes

Batch mode yes

Network capabilities yes

Compatibility with the MR6 controller yes

TECHNICAL SPECIFICATION

Ai012/V1

Freezer control with batch option

Page 8: Controlled Rate Freezers Benchtop Incubators Alarms & … · 2018-11-26 · Controlled Rate Freezers Benchtop Incubators Alarms & Monitoring Sample Tracking. Planer plc ... we have

Keep safe in the laboratory. We provide a range of equipment to protect your people.

Cryo-apronMade from state of the art materials, the cryo-apron has thermal protection, with a waterproof nylon outer shell protecting the wearer from cryogenic splashes.

Face Shield, goggles and spectaclesSpecialist eyewear to block ultraviolet radiation.

LN2 Safety GlovesThe LN2 safety gloves are designed for handling objectives in the vapour phase of liquid nitrogen.

Oxygen MonitorMonitor the oxygen levels in your rooms with visual and audible alarms.

spectacles

FREEZING

Sensors, accessories & personal protection equipment

PRODUCT NAME/ NUMBER DESCRIPTION

Personal Alarm Personal CO2 & O2 portable alarm

Oxygen Monitor Oxygen Monitor for Rooms with LCD, 4-20mA, Repeater with visual and Audible alarms

Face Shield, Goggles and Spectacles Eyewear blocks ultraviolet radiation

Apron Cryo Apron is also made from state of the art materials. The multi-layered construction allows for a maximum level of thermal protection, and a waterproof nylon outer shell protects from cryogenic splashes

Glove (large & medium) LN2 Safety Gloves specially developed for handling ob-jects stored in the vapour phase of liquid nitrogen

TECHNICAL SPECIFICATION

Di013/V1

Sensors, accessories & personal protection equipment

Page 9: Controlled Rate Freezers Benchtop Incubators Alarms & … · 2018-11-26 · Controlled Rate Freezers Benchtop Incubators Alarms & Monitoring Sample Tracking. Planer plc ... we have

Controlled Rate Freezer Comparison Table

Model Kryo 360-1.7 Kryo 360-3.3 Kryo 560-16 Kryo 750-30 Kryo 1060-180 Kryo 1060-380

�������������������� �������������������

�,$%) ������� �.3,������ �.3,������ �.3,����� �.3,������� �.3,������� �.3,� ���� �.3,��������� �.3,��������

�'!*"%.���� ��� ��� ��� � � � � ��� ��

�0.!2�!-!#(03

��,����#"���,����#"

���,����#" ��,����#"

���,����#" ��,����#"

���,����#" ��,����#" �������

�$�����#"� �������

�$�����#"��� ������$�����#"�

����������$�����#"�

�����������$�����#"�

�*-,1)%�!-!#(03��*)�

�0!+$!.$

� �� �� �� ��)!�*������$�)��

��)!�*������$�)��

��)!�*���

��$�)���

��� ����

�),,$��!&�!-!#(03

������� ��*)��� ��� ��� ��� �� ��

��"��)��$'+ (�

�"��)��$'+ (�

�,+0.,))%$�!+&%

�%%#�*%����.�

�%%#�*%����.�

��.��*%����.�

��.��*%�����.�

�.��*%�����.�

�.�� *%����.�

���.��*%�� �.�

��.�� *%� �� �.�

��.�� *%� �� �.�

�,,)(+&��!0%/�5���(+�

������*%���� ������*%���� ������*%���� ������*%���� ������*%���� ������*%���� ������*%���� ������*%��� ������*%���

�,+0.,))%$�%!0(+&��!0%/

�5���(+�

�����*%�������+&&"-

�����*%���%(#�"�

�����*%��� �����*%��� �����*%��� �����*%��� �����*%��� �����*%��� �����*%�� �����*%��

�.%%4(+&�)(&+*%+0 ��(* ��""- �%*� �%*� �%*� ��(* ��""- ��(* ��""- �%*� ��(* ��""- ��(* ��""-

�3/0%*�,+0.,))%.

�+ "*� $ ��� ��� ��� �+ "*� $ ��� �+ "*� $ ��� ���

���������� �����

�������������������� �������������������

�,$%) ������� �.3,������ �.3,������ �.3,����� �.3,������� �.3,������� �.3,� ���� �.3,��������� �.3,��������

�'!*"%.���� ��� ��� ��� � � � � ��� ��

�0.!2�!-!#(03

��,����#"���,����#"

���,����#" ��,����#"

���,����#" ��,����#"

���,����#" ��,����#" �������

�$�����#"� �������

�$�����#"��� ������$�����#"�

����������$�����#"�

�����������$�����#"�

�*-,1)%�!-!#(03��*)�

�0!+$!.$

� �� �� �� ��)!�*������$�)��

��)!�*������$�)��

��)!�*���

��$�)���

��� ����

�),,$��!&�!-!#(03

������� ��*)��� ��� ��� ��� �� ��

��"��)��$'+ (�

�"��)��$'+ (�

�,+0.,))%$�!+&%

�%%#�*%����.�

�%%#�*%����.�

��.��*%����.�

��.��*%�����.�

�.��*%�����.�

�.�� *%����.�

���.��*%�� �.�

��.�� *%� �� �.�

��.�� *%� �� �.�

�,,)(+&��!0%/�5���(+�

������*%���� ������*%���� ������*%���� ������*%���� ������*%���� ������*%���� ������*%���� ������*%��� ������*%���

�,+0.,))%$�%!0(+&��!0%/

�5���(+�

�����*%�������+&&"-

�����*%���%(#�"�

�����*%��� �����*%��� �����*%��� �����*%��� �����*%��� �����*%��� �����*%�� �����*%��

�.%%4(+&�)(&+*%+0 ��(* ��""- �%*� �%*� �%*� ��(* ��""- ��(* ��""- �%*� ��(* ��""- ��(* ��""-

�3/0%*�,+0.,))%.

�+ "*� $ ��� ��� ��� �+ "*� $ ��� �+ "*� $ ��� ���

���������� �����

�������������������� �������������������

�,$%) ������� �.3,������ �.3,������ �.3,����� �.3,������� �.3,������� �.3,� ���� �.3,��������� �.3,��������

�'!*"%.���� ��� ��� ��� � � � � ��� ��

�0.!2�!-!#(03

��,����#"���,����#"

���,����#" ��,����#"

���,����#" ��,����#"

���,����#" ��,����#" �������

�$�����#"� �������

�$�����#"��� ������$�����#"�

����������$�����#"�

�����������$�����#"�

�*-,1)%�!-!#(03��*)�

�0!+$!.$

� �� �� �� ��)!�*������$�)��

��)!�*������$�)��

��)!�*���

��$�)���

��� ����

�),,$��!&�!-!#(03

������� ��*)��� ��� ��� ��� �� ��

��"��)��$'+ (�

�"��)��$'+ (�

�,+0.,))%$�!+&%

�%%#�*%����.�

�%%#�*%����.�

��.��*%����.�

��.��*%�����.�

�.��*%�����.�

�.�� *%����.�

���.��*%�� �.�

��.�� *%� �� �.�

��.�� *%� �� �.�

�,,)(+&��!0%/�5���(+�

������*%���� ������*%���� ������*%���� ������*%���� ������*%���� ������*%���� ������*%���� ������*%��� ������*%���

�,+0.,))%$�%!0(+&��!0%/

�5���(+�

�����*%�������+&&"-

�����*%���%(#�"�

�����*%��� �����*%��� �����*%��� �����*%��� �����*%��� �����*%��� �����*%�� �����*%��

�.%%4(+&�)(&+*%+0 ��(* ��""- �%*� �%*� �%*� ��(* ��""- ��(* ��""- �%*� ��(* ��""- ��(* ��""-

�3/0%*�,+0.,))%.

�+ "*� $ ��� ��� ��� �+ "*� $ ��� �+ "*� $ ��� ���

���������� �����

�������������������� �������������������

�,$%) ������� �.3,������ �.3,������ �.3,����� �.3,������� �.3,������� �.3,� ���� �.3,��������� �.3,��������

�'!*"%.���� ��� ��� ��� � � � � ��� ��

�0.!2�!-!#(03

��,����#"���,����#"

���,����#" ��,����#"

���,����#" ��,����#"

���,����#" ��,����#" �������

�$�����#"� �������

�$�����#"��� ������$�����#"�

����������$�����#"�

�����������$�����#"�

�*-,1)%�!-!#(03��*)�

�0!+$!.$

� �� �� �� ��)!�*������$�)��

��)!�*������$�)��

��)!�*���

��$�)���

��� ����

�),,$��!&�!-!#(03

������� ��*)��� ��� ��� ��� �� ��

��"��)��$'+ (�

�"��)��$'+ (�

�,+0.,))%$�!+&%

�%%#�*%����.�

�%%#�*%����.�

��.��*%����.�

��.��*%�����.�

�.��*%�����.�

�.�� *%����.�

���.��*%�� �.�

��.�� *%� �� �.�

��.�� *%� �� �.�

�,,)(+&��!0%/�5���(+�

������*%���� ������*%���� ������*%���� ������*%���� ������*%���� ������*%���� ������*%���� ������*%��� ������*%���

�,+0.,))%$�%!0(+&��!0%/

�5���(+�

�����*%�������+&&"-

�����*%���%(#�"�

�����*%��� �����*%��� �����*%��� �����*%��� �����*%��� �����*%��� �����*%�� �����*%��

�.%%4(+&�)(&+*%+0 ��(* ��""- �%*� �%*� �%*� ��(* ��""- ��(* ��""- �%*� ��(* ��""- ��(* ��""-

�3/0%*�,+0.,))%.

�+ "*� $ ��� ��� ��� �+ "*� $ ��� �+ "*� $ ��� ���

���������� �����

�������������������� �������������������

�,$%) ������� �.3,������ �.3,������ �.3,����� �.3,������� �.3,������� �.3,� ���� �.3,��������� �.3,��������

�'!*"%.���� ��� ��� ��� � � � � ��� ��

�0.!2�!-!#(03

��,����#"���,����#"

���,����#" ��,����#"

���,����#" ��,����#"

���,����#" ��,����#" �������

�$�����#"� �������

�$�����#"��� ������$�����#"�

����������$�����#"�

�����������$�����#"�

�*-,1)%�!-!#(03��*)�

�0!+$!.$

� �� �� �� ��)!�*������$�)��

��)!�*������$�)��

��)!�*���

��$�)���

��� ����

�),,$��!&�!-!#(03

������� ��*)��� ��� ��� ��� �� ��

��"��)��$'+ (�

�"��)��$'+ (�

�,+0.,))%$�!+&%

�%%#�*%����.�

�%%#�*%����.�

��.��*%����.�

��.��*%�����.�

�.��*%�����.�

�.�� *%����.�

���.��*%�� �.�

��.�� *%� �� �.�

��.�� *%� �� �.�

�,,)(+&��!0%/�5���(+�

������*%���� ������*%���� ������*%���� ������*%���� ������*%���� ������*%���� ������*%���� ������*%��� ������*%���

�,+0.,))%$�%!0(+&��!0%/

�5���(+�

�����*%�������+&&"-

�����*%���%(#�"�

�����*%��� �����*%��� �����*%��� �����*%��� �����*%��� �����*%��� �����*%�� �����*%��

�.%%4(+&�)(&+*%+0 ��(* ��""- �%*� �%*� �%*� ��(* ��""- ��(* ��""- �%*� ��(* ��""- ��(* ��""-

�3/0%*�,+0.,))%.

�+ "*� $ ��� ��� ��� �+ "*� $ ��� �+ "*� $ ��� ���

���������� �����

�������������������� �������������������

�,$%) ������� �.3,������ �.3,������ �.3,����� �.3,������� �.3,������� �.3,� ���� �.3,��������� �.3,��������

�'!*"%.���� ��� ��� ��� � � � � ��� ��

�0.!2�!-!#(03

��,����#"���,����#"

���,����#" ��,����#"

���,����#" ��,����#"

���,����#" ��,����#" �������

�$�����#"� �������

�$�����#"��� ������$�����#"�

����������$�����#"�

�����������$�����#"�

�*-,1)%�!-!#(03��*)�

�0!+$!.$

� �� �� �� ��)!�*������$�)��

��)!�*������$�)��

��)!�*���

��$�)���

��� ����

�),,$��!&�!-!#(03

������� ��*)��� ��� ��� ��� �� ��

��"��)��$'+ (�

�"��)��$'+ (�

�,+0.,))%$�!+&%

�%%#�*%����.�

�%%#�*%����.�

��.��*%����.�

��.��*%�����.�

�.��*%�����.�

�.�� *%����.�

���.��*%�� �.�

��.�� *%� �� �.�

��.�� *%� �� �.�

�,,)(+&��!0%/�5���(+�

������*%���� ������*%���� ������*%���� ������*%���� ������*%���� ������*%���� ������*%���� ������*%��� ������*%���

�,+0.,))%$�%!0(+&��!0%/

�5���(+�

�����*%�������+&&"-

�����*%���%(#�"�

�����*%��� �����*%��� �����*%��� �����*%��� �����*%��� �����*%��� �����*%�� �����*%��

�.%%4(+&�)(&+*%+0 ��(* ��""- �%*� �%*� �%*� ��(* ��""- ��(* ��""- �%*� ��(* ��""- ��(* ��""-

�3/0%*�,+0.,))%.

�+ "*� $ ��� ��� ��� �+ "*� $ ��� �+ "*� $ ��� ���

���������� �����

Chamber (Litres) 1.7 3.3 16 30 180 380

Straw Capacity60 (0.25ml) 45 (0.5ml)

60 (0.25ml) 45 (0.5ml)

2904 (0.25ml) 1210 (0.5ml) on canes

456 (0.25ml-0.5ml) on racks

5808 (0.25ml) 2420 (0.5ml) on canes

836 (0.25ml-0.5ml) on racks

5000 (0.25ml and 0.5ml) 10500 (0.25 and 0.5ml)

Vial Capacity 30 (2ml) 60 (2ml)784 (1.0ml - 2.0ml)

244 (5.0ml)1452 on canes 784 in baskets

4000 (2ml) 8000 (2ml)

Blood Bag Capacity N/A N/A22 (50ml)

11 (250ml - 500ml)48 (PALL bags)

20 (250 - 1000 ml)96 (PALL bags)

Please Enquire Please Enquire

Controlled Range 40°C to -180°C 40°C to -180°C 30°C to -180°C 100°C to -160°C 40°C to -100°C 40°C to -100°C

Cooling Rates-0.01 to -50

(°C/Min)-0.01 to -50

(°C/Min)-0.01 to -50

(°C/Min)-0.01 to -10

(°C/Min)-0.01 to -5 (°C/Min)

-0.01 to -5 (°C/Min)

Controlled Heating Rates0.01 to 10 (°C/Min)

0.01 to 10 (°C/Min)

0.01 to 10 (°C/Min)

0.01 to -99.9 (°C/Min)

0.01 to 1 (°C/Min)

0.01 to 1 (°C/Min)

Freezing Alignment Both Both Vertically Both Vertically Vertically

System Controller MRV MRV MRV Built-in KS1 KS1

Planer plc110 Windmill Road, Sunbury-On-ThamesMiddlesex TW16 7HD, United Kingdom

Tel: +44 (0)1932 755 000 Fax: +44 (0)1932 755 001

[email protected]

Specifications may change without notice, third party trademarks acknowledged. Ai014/V1

© 2016 Planer plc

Page 10: Controlled Rate Freezers Benchtop Incubators Alarms & … · 2018-11-26 · Controlled Rate Freezers Benchtop Incubators Alarms & Monitoring Sample Tracking. Planer plc ... we have

Provide your cells with a near in vivo culture environment with the BT37 benchtop incubator – ideal for human and animal IVF and stem cell applications.

The incubator keeps cells at an optimal temperature, humidity and gas content by maintaining a constant and clean environment.

Within sample dishes, the BT37 has unrivalled temperature accuracy – essential for providing an outstanding cell culture environment.

Easy to use, each chamber in this compact incubator can be set independently – and can be continuously monitored via your web browser.

All critical operating parameters are password protected for additional security.

temperature and gas control

temperature and gas recovery

power failure

variety of different culture dishes

independent monitoring options Want to find out more about benchtop incubators? [email protected]

INCUBATING

BT37

Benchtop incubator

PHYSICAL

Dimensions 420 mm wide x 270 mm deep x 210 mm high

Weight 15.5 kg

Storage temperature -10 °C to +50 °C

Storage humidity 5% to 95% relative humidity non-condensing

Operating environment For indoor use only

Operating temperature +5 °C to +40 °C for safe operation. See also temperature control range restriction.

Operating humidity 10% to 90% relative humid-ity non-condensing

Altitude up to 2000 m

Pollution degree Pollution degree 2 (BS EN61010-1)

CONTROL

Temperature control range

(ambient + 5 °C) to 40 °C.

Temperature measurement accuracy

± 0.2 °C

Temperature control accuracy

± 0.1 °C measured after any transient effects due to set-point changes have subsided.

Flow control range 0 ml/minute to 900 ml/minute. Flow measurements are normalised to 0 C , 50% RH and 1 bar.

Flow accuracy The greater of ± 10% or ± 0.3 ml/minute

Flow control accuracy The greater of ± 5% or ± 0.2 ml/minute measured after any transient effects due to set-point changes have subsided.

CAPACITY

Dishes per chamber 4 x NUNC 4 well dishes 4 x NUNC 60 mm dishes 10 x NUNC 30 mm dishes4 x MINITUB 5 well dishes 4 x FALCON 60 mm dishes 4 x FALCON 60mm single-well“organ culture” dishes& many more types ac-cepted

POWER

Power requirements (see note) Includes Controller

100 - 230 V~ / 50/60Hz / 1.1 A

Internal battery backup

Gelled sealed lead acid battery / 12 v x 12 Ah

GAS SUPPLY

Gas supply Premixed gas. Typically 6% CO2, 5% O2, balance N2

Supply pressure 1.5 ± 0.15 bar

Connectors Regulator must be supplied with Swagelok 1/4” connection SS-400-1-4RT

ALARMS

Alarms The incubator provides 3 volt-free terminals which provide normally-open and normally-closed contacts.

REMOTE MONITORING

LAN 10 Base T Ethernet - RJ45 shielded. Modbus-TCP-IP protocol.

Remote PT100 sen-sors

PT100 Class A to EN60751 Maximum diameter 2.51 mm. Minimum length 100 mm. Sensing region should be within 15 mm of the tip..

BT37

TECHNICAL SPECIFICATION

Bi015/V1

Benchtop incubator humidity controlled

Page 11: Controlled Rate Freezers Benchtop Incubators Alarms & … · 2018-11-26 · Controlled Rate Freezers Benchtop Incubators Alarms & Monitoring Sample Tracking. Planer plc ... we have

Ideal for non-clinical culture applications, the INC-A20 provides high precision temperature and gas regulation, modest footprint and integrated sample protection.

The Planer benchtop incubator provides a precisely controlled environment, with accurate control of the chamber, ensuring a cell or embryo suffers little or no exposure to temperature or pH level changes.

The compact size allows placement in cabinets and the two chambers allow samples to be processed separately. Full control over the gas flow is provided, allowing gas usage to be minimised.

consumption a fraction of large incubators

power failure

consumable costs

status indicators Want to find out more about benchtop incubators? [email protected]

INCUBATING

INC-A20

Benchtop incubator: No Humidity

PHYSICAL

Dimensions 420 mm wide x 270 mm deep x 210 mm high

Weight 15.5 kg

Storage temperature -10 °C to +50 °C

Storage humidity 5% to 95% relative humidity non-condensing

Operating environ-ment

For indoor use only

Operating tempera-ture

+5 °C to +40 °C for safe operation. See also temperature control range restriction.

Operating humidity 10% to 90% relative humidity non-condensing

Altitude up to 2000 m

Pollution degree Pollution degree 2 (BS EN61010-1)

CONTROL

Temperature control range

(ambient + 5 °C) to 40 °C.

Temperature meas-urement accuracy

± 0.2 °C

Temperature control accuracy

± 0.1 °C measured after any transient effects due to set-point changes have subsided.

Flow control range 0 ml/minute to 900 ml/minute. Flow measurements are normalised to 0 C , 50% RH and 1 bar.

Flow accuracy The greater of ± 10% or ± 0.3 ml/minute

Flow control accu-racy

The greater of ± 5% or ± 0.2 ml/minute measured after any transient effects due to set-point changes have subsided.

CAPACITY

Dishes per chamber 4 x NUNC 4 well dishes 4 x NUNC 60 mm dishes 10 x NUNC 30 mm dishes 4 x MINITUB 5 well dishes 4 x FALCON 60 mm dishes 4 x FALCON 60mm single - well “organ culture” dishes

POWER

Power requirements (see note) Includes Controller

100 - 230 V~ / 50/60Hz / 1.1 A

Internal battery backup

Gelled sealed lead acid bat-tery / 12 v x 12 Ah

GAS SUPPLY

Gas supply Premixed gas. Typically 6% CO2, 5% O2, balance N2

Supply pressure 1.5 ± 0.15 bar

Connectors

ALARMS

Alarms The incubator provides 3 volt-free terminals which provide normally-open and normally-closed contacts.

REMOTE MONITORING

LAN 10 Base T Ethernet - RJ45 shielded. Modbus-TCP-IP protocol.

Remote PT100 sen-sors

PT100 Class A to EN60751. Maximum diameter 2.51 mm. Minimum length 100 mm. Sensing region should be within 15 mm of the tip.

INC-A20

TECHNICAL SPECIFICATION

Bi016/V1

Benchtop incubator not humidity controlled

Page 12: Controlled Rate Freezers Benchtop Incubators Alarms & … · 2018-11-26 · Controlled Rate Freezers Benchtop Incubators Alarms & Monitoring Sample Tracking. Planer plc ... we have

A comprehensive monitoring system for your laboratory and biological samples, ReAssure can help compliancy. Scalable from 1 to 1,000 sensors, this system allows you to monitor and record alarm events for your laboratory and equipment.

Reassure collects, stores and helps report data from your laboratory equipment. Sensors can monitor CO2, 02, humidity, pH, temperature and door status for a range of devices such as benchtop incubators, big box incubators, vessel controllers and LN dewars.

The Reassure system is very flexible, allowing you to add additional sensors as your needs evolve. Our current range of compatible sensors include the flat temperature sensors, the wireless temperature / level sensor and the latest Petri dish CO2/pH sensor.

ReAssure is available as a cloud-based or installed system.

benchtop incubators

box incubators

controllers

vessels

module

Want to find out more about monitoring? [email protected]

MONITORING

ReAssure

ReAssure

REASSURE

No of sensors supported (per module)

Up tp 50

Local data logging Yes

Temperature Yes

O2 Yes

Door status Yes

Environmental O2 Yes

Benchtop incubator O2 Yes

LN2 Yes

Pressure Yes

Compliant ‘cloud’ storage Yes

User definable searching Yes

Exception reporting Yes

Modbus connection Yes

Connection to vessel controllers Yes

Configure & Status

Local Area Network

N2 Vessels &

Dewars

CO2

Incubators

Benchtop

Incubators

Fridges &

Freezers

Visual & Audible Email SMS Phone Call

TECHNICAL SPECIFICATION

Ci017/V1

Compliant monitoring

Page 13: Controlled Rate Freezers Benchtop Incubators Alarms & … · 2018-11-26 · Controlled Rate Freezers Benchtop Incubators Alarms & Monitoring Sample Tracking. Planer plc ... we have

v

Keeping a busy laboratory safe and compliant can be difficult. The DATAcentre standalone alarm system can help you look after your valuable samples and the safety of your team.

The DATAcentre base station can support up to 120 sensors to monitor temperature, humidity, carbon dioxide. liquid nitrogen and oxygen levels, the door status and much more. You can extend the system by adding additional base stations.

If there is an alarm, text or email alerts can be sent to key personnel wherever they are in the world. As every alarm event is logged and access only by password can be configured, a complete audit trail is easily available either via the base centre or web browser.

visible, audible and email alerts

expensive installationWant to find out more about monitoring? [email protected]

MONITORING

DATAcentre

Monitoring and alarm system

Features local area network (LAN

Sensors

phone call alarms

connect directly to the system

GENERAL

Dimensions 200mm (W) x 140mm (H) 55mm (D)

Weight 550 to 800g depending on fitted modules

Operating Temp. 0°C to 40°C

Material 4mm thick High Impact UL94V0 Fire rated polystyrene

Supply 5V DC via external power brick (Supplied)

Operating System Embedded

Processor DS400 with 2M flash 1M Static Ram

Display High contrast 128 x 64 graphics display

USER MANAGEMENT

Passwords Service and user level passwords

Log Alarm and event log

ARCHIVE DATA & REPORT

MMC (Mass Storage)

2GB providing 1 yrs archived data at 1m interval

USB USB 2.0 (For reports and data backup)

HACCP HTML & CSV reports produced daily to internal MMC

BATTERY BACK UP OPTIONS

Part Number Description

FTEM02LCMU101/ BB

Battery Backup 3.5 Hour Internal

FTEM02BBU101 Battery Backup 15 hour External

FPLG60T Uninterruptible power supply which powers the DATAcentre for at least 27 minutes without mains power

ALARM NOTIFICATION

Screen Provides real-time data detailing current alarm status

LED LED Traffic light style (OK, WARNING, ALARM)

Sounder Internal sounder

Relay Single volt free relay output providing NC & NO contacts

Email Up to 5 external email addresses

IP Alarm message directed to up to 3 IP addresses

LOW POWERED RADIO MODULE

Frequency 433MHz (Europe) licence free, 6 channels 915MHz (US) licence free, 6 channels

Power 10mW maximum

Communications Bi-directional

Protocol Proprietary

SENSOR TYPES

Internal inputs Up to 8 hardwired temperature and/or volt- free digital inputs

Networked inputs Up to 20, 8 channel modules providing temperature and volt free digital inputs

Wireless Up to 120 devices providing temperature, humidity, 4-20 mA, pulse count and volt-free digital inputs

TECHNICAL SPECIFICATIONS

Memory Capacity 16 Points 32 Points 64 Points 120 Points

2GB (std) 5.1 years 2.7 years 1.4 years 0.7 years

DATAcentre

TECHNICAL SPECIFICATION

Ci018/V1

Wireless monitoring and alarm system

Page 14: Controlled Rate Freezers Benchtop Incubators Alarms & … · 2018-11-26 · Controlled Rate Freezers Benchtop Incubators Alarms & Monitoring Sample Tracking. Planer plc ... we have

Keep an eye on the temperature of your valuable samples, during transit, with our liquid nitrogen vapour shipper data logger. ShipsLog™ keeps an accurate, downloadable temperature history of your samples throughout their journey.

The ShipsLog™ monitor is fitted in the top of the dry shipper’s cover, with the temperature probe measuring the warmest part of the vapour shipper. Alarms can be set at predetermined intervals during transit.

On arrival, the recipient can check whether the temperature range has deviated from the pre-set profile.

The complete temperature history can be downloaded, giving the exact temperature pattern throughout the journey. The logger is user programmable via PC software – and the logging process can be started either via PC software or a magnetic swipe key.

Want to find out more about monitoring? [email protected]

MONITORING

ShipsLog

ShipsLog™ for vapour shippers

MEASUREMENT

Range -200°C to 0°C

PC Programme Display units user selectable -°C, °F or K

Probe Type Platinum Resistance, Pt 100, Class B

Accuracy ±1.5°C at 0°C, rising to ±2.5°C at -200°C, including uncertainty due to measurement resolution and probe errors

Calibration Traceable to NAMAS standards; semi-automatic user calibration possible using optical PC calibration pack; calibration certificate printed automatically

DATA LOGGING

Number of points 8192

Logging Interval 30 seconds to 99 minutes in 30 second increments

Logging Resolution 0.1°C

Max Number of Logs 8192 (Limited to number of points)

ALARM GENERATION

High Alarm Level -200°C to 0°C in 1.0°C steps

Low Alarm Level -200°C to 0°C in 1.0°C steps

Alarm Delay Period 0 to 120 logging intervals

CONTROL & INDICATION

Manual Control Magnetic non contact Start / Stop Switch using supplied fob

Communication RS232 Serial communications to proprietary PC program

Programming Using propriety PC program

Indicators Three x LED Indicators: Yellow=Normal, Orange=Warning,

BATTERY

Type Lithium Thionyl Chloride, internally fitted, factory replaceable

Life Approximately 3 years in normal operation; battery life remaining is indicated via PC programme

PC Software Requirements

PC to be Windows ‘95, ‘98 or NT

ORDERING INFORMATION

Description Ordering Ref

ShipsLog with temperature probe

GDSHIPSLOG-FL

ShipsLog with fixed probe 720mm long

GDSHIPSLOG-FL-720

ShipsLog for Cryoshipper vapour shipper

GDSHIPSLOG-CS

ShipsLog for SC4/3V vapour shipper

GDSHIPSLOG-SC4/3V

ShipsLog for SC4/2V vapour shipper

GDSHIPSLOG-SC4/2V

Temperature Probe for ShipsLog

GDSHIPSLOG-PRT-610MM

Serial Cable to connect ShipsLog to PC

AC013808

Please refer to your vessel documentation for details. Note that use of the ShipsLog for the SC4/3V could result in an increase in liquid nitrogen evaporation rate of 22% and this may affect the hold-up time of the system.

TECHNICAL SPECIFICATION

Ci019/V1

Data logger for vapour shippers

Page 15: Controlled Rate Freezers Benchtop Incubators Alarms & … · 2018-11-26 · Controlled Rate Freezers Benchtop Incubators Alarms & Monitoring Sample Tracking. Planer plc ... we have

Monitor benchtop incubators or heated stages easily and reliably with our range of innovative and versatile temperature sensors. Designed to work with equipment without access ports, with an ultra-small footprint these sensors can be used with both wired and wireless alarm and monitoring systems – to provide precise and continuous temperature monitoring.

Benchtop incubator monitoringThe small size of culture chambers found in benchtop incubators can make independent temperature measurement difficult. These temperature sensors include an ultra-thin connecting cable which can pass under the seal of an incubation chamber without adversely affecting the gas concentration. The flat sensor head is in contact with the lower surface of the incubation chamber, giving users a precise indication of the temperature samples are exposed to.

Surface temperature monitoringComprising a small sensor head (6.35 x 13 x 1.3mm) and a thin connecting cable, this sensor is ideally suited to the monitoring of heated surfaces without interfering with workflow. This type of sensor also benefits from being resistant to moisture and it can be partly submerged without affecting temperature readings. Users are able to disinfect the sensor using alcohol, making it ideally suited for the monitoring of cell culture environments.

access ports

Straightforward installation with annual calibration

Use as part of a wired or wireless system

MONITORING

Flat temperature sensors

Measurement Range -200°C to 260°C

Calibration Frequency Annual

Moisture Resistant Yes

Accuracy +/- 0.3°C at 0°C

Operating Temperature 0°C to 70°C (limited by connector type)

Benchtop Incubator Flat Sensor: For in chamber temperature monitoring

Measurement Range 0°C to 50°C

Calibration Frequency Annual

Moisture Resistant Yes

Accuracy +/- 0.3°C at 0°C

Operating Temperature 0°C to 70°C (limited by connector type)

Surface Temperature Sensor: For ICSI Rig or heated platform

TECHNICAL SPECIFICATION

Ci020/V1

Flat temperature sensors

Page 16: Controlled Rate Freezers Benchtop Incubators Alarms & … · 2018-11-26 · Controlled Rate Freezers Benchtop Incubators Alarms & Monitoring Sample Tracking. Planer plc ... we have

Measure pH / CO2 in bench top incubators, big box incubators and environmental chambers with our Petri dish pH / CO2 sensor which includes a detector shaped into a standard 35mm Petri dish and an ultra thin ribbon cable.

The new sensor is available as a stand-alone unit, with a display option which can be used to help validate CO2 and provide virtual pH in a variety of laboratory equipment. It also has the ability to be used for continuous measurement as part of a monitoring system.

The system uses the established relationship between CO2 and pH to produce reproducible indications of pH culture conditions.

The Petri dish sensor can also be used as part of a new or existing monitoring and alarm system.

Providing standard outputs and a small footprint makes for uncomplicated integration.

The sensor size (equivalent to a 35mm petri dish) combined with an ultra-thin ribbon cable makes installation into any device straightforward.

Easy installation

incubators and environmental chambers

Use as a static monitoring sensor or a validation tool

With only an annual calibration

Reliable results With no pH drift due to sensor saturation

Want to find out more about monitoring? [email protected]

MONITORING

Petri dish pH / CO2 sensor

Operating Temperature 10°C to 42°C

Storage Temperature -40°C to +80°C

Sensor Type Infrared Sensor

Power Supply 3.6 to 5 V

Accuracy ±50 ppm, ± 3% of Reading

Power Consumption <33 mW

Size Equivalent to 35mm NUNC-150255 IVF Petri dish (35 mm x 10 mm)

Measurement Range 0-20% CO2 , 0-14 virtual pH

Life Span Five years

Output 4-20 mA

Alarm Audio/Visual alarm on control

Calibration Frequency Annual

Computed pH The relationship between CO2, bicarbonate concentration in buffered media and atmospheric pressure, allows a pH value to be computed without the expense or inconvenience of traditional pH measuring devices.

The relationship between pH and CO2 concentration is well characterised for all leading culture media. Here is the characterisation of the Origio blastocyst media.

Using the relationship between CO2 and pH, the Petri dish pH / CO2 sensor can determine the effect of environmental CO2 change on the pH in culture media.

Option 1 Use as stand-alone alarm option for CO2 and pH

Option 2Download our free app to enable portable CO2 and pH monitoring and validation

Option 3 Use as a sensor option for a new or existing monitoring system

+

+ Monitoring

TECHNICAL SPECIFICATION

Ci021/V1

Petri dish pH / CO2 sensor

Page 17: Controlled Rate Freezers Benchtop Incubators Alarms & … · 2018-11-26 · Controlled Rate Freezers Benchtop Incubators Alarms & Monitoring Sample Tracking. Planer plc ... we have

Continuous monitoring of high value cryogenic samples is not only good laboratory practice, but also often a regulatory requirement. This new wireless temperature and level sensor combines accurate temperature measurement in liquid nitrogen storage vessels with liquid level monitoring – helping scientists to ensure stored cells and tissues are maintained in an optimal environment.

This latest addition to our expansive range of monitoring sensors give users the flexibility of wireless temperature and level monitoring in addition to the popular wired version. Incorporating a high accuracy Pt100 platinum sensor, this option provides +/-0.3oC precision measurement between +150oC and -200oC.

Unlike traditional thermocouple measuring devices, the new wireless temperature/level sensor is not subject to recorded drift after calibration, meaning the sensors stay more accurate for longer between service visits.

The sensor is installed at a user defined height and will produce an alarm if the level falls below this point. This provides the user with 24/7 temperature and liquid nitrogen level monitoring and provides clear traceability that samples have been stored in optimal conditions.

Easy Installation

with an adjustable sensor shape

Reliable Operation Independent battery power supply for continuous monitoring

Wireless connectivity allows

without interruption

Durable Sensor moulded around contour of dewar reduces chance of damage

Want to find out more about monitoring? [email protected]

MONITORING

Wireless temperature/level sensor

Sensor Type Dual level and Platinum Resistance Thermometer 100

Battery Life Five years for temperature and one year for level

Suitability Any aluminium LN2 tank. Can be any length, standard lengths are 450mm and 750mm

Compatibility DATAcentre range of monitoring, up to 120 per system

Temperature Range -200°C to + 150°C

Temperature accuracy ±0.3°C at 0°C, ±2.04 at -200°C

Calibration Annually

Mounting No drilling of cork; mounted around the neck. Battery pack mounted using strapping

Installation Can be performed with fully working tank full with samples

Transmission Range Approximately 100m. Depends on number of walls, wall construction, etc.

Data Can be viewed via base station or over network PC, tablet or phone

Temperature/level sensors are now available for both wired and wireless ReAssure configurations. Wired systems benefit from utilising the users existing IT infrastructure while wireless systems provide a smaller installation footprint and are unaffected by local network interruptions. Users also can benefit from hybrid systems to best meet their requirements.

TECHNICAL SPECIFICATION

Ci022/V1

Wireless temperature/level sensor

Page 18: Controlled Rate Freezers Benchtop Incubators Alarms & … · 2018-11-26 · Controlled Rate Freezers Benchtop Incubators Alarms & Monitoring Sample Tracking. Planer plc ... we have

Significantly reduce the amount to time to recover stored samples with the Pro-Curo inventory management solution.

Pro-Curo is simple to get up and running so no intense training will be required. And if you do have a problem, there is around the clock telephone support.

The software can be quickly adapted to your needs – whether you need to track your specimens across multiple sites or need add a patient consent form to sample information.

The software is fully FDA CFR 21 part 11 Compliant, giving you complete history of every transaction and an auditable trail of your samples.

Sign up for a 14 day free trial to see just how easy Pro-Curo software is to get up and running to track samples in your laboratory.

one lab up to multiple sites

with bar code readers

attachments

traceability for all samples

control Want to find out more about tracking your samples? [email protected]

STORING

Sample tracking softwarePro-Curo

Version LITE PRO ENT

FEATURES

Max no of samples 1,000,000 10,000,000 100,000,000

Complete history of every trans-action

Yes Yes Yes

Multi user No Yes - 5 Yes - 5, 10, Unlimited

Database structure Microsoft Access Microsoft Access MSSQL & MySql

User manager Yes Yes Yes

MySamples No No Yes

Sample view restricted by project No Yes Yes

Auto logoff function No Yes Yes

Split samples function Yes Yes Yes

Customisable user fields. Yes Yes Yes

Edit multiple samples No No Yes

Book in and book out function. Yes Yes Yes

Multi level location structure Yes - 5 Yes - 7 Yes - 7

X/Y sublocations (box/plate level) No No Yes

Grid view No No Yes

Standard report generation Yes Yes Yes

Custom reports No No Yes

Label design Basic Graphical Graphical

Barcode generation* 2D - Only 1D & 2D 1D & 2D

Data import function No No Yes

Sample search function Yes Yes Yes

Advanced SQL search builder No No Yes

Date alerts No No Yes

Double blind auditing function. Yes Yes Yes

History archive function Yes Yes Yes

Internal messaging No No Yes

TECHNICAL SPECIFICATION

Di023/V1

Sample tracking software

Page 19: Controlled Rate Freezers Benchtop Incubators Alarms & … · 2018-11-26 · Controlled Rate Freezers Benchtop Incubators Alarms & Monitoring Sample Tracking. Planer plc ... we have

Planer PLC110 Windmill Road

Sunbury-On-Thames

Middlesex TW16 7HD

United Kingdom

Tel: +44 (0)1932 755 000

Fax: +44 (0)1932 755 001

[email protected]

www.planer.com

We help Researchers, Embryologists and Medics look after cells

There are over eighty distributors worldwide for sales and support see:

www.planer.com

FREEZING INCUBATING MONITORING STORING

Di024/V1