1
EXPANDED METAL LATH (ASTM C847), 3.4#SY, SELF FURRED OR WOVEN WIRE (ASTM C1032), OR WELDED WIRE (ASTM c933), 17 ga W/ OPENINGS NOT TO EXCEED 1.5IN. - LATH ACCESSORIES (ASTM C653) STRUCTURALLY ATTACH LATH OR WIRE TO WALL FRAMING SUPPORTS EVERY 7 INCHES (MAXIMUM) VERTICALLY UP THE STUD. ADDITIONAL INTERMITTENT FASTENING TO SHEATHING TO SMOOTH OUT DRAPING IS PERMITTED SECOND LAYER OF WATER-RESISTIVE (BOND BREAK) BARRIER WITH A PERFORMANCE AT LEAST EQUIVALENT TO GRADE "D" BUILDING PAPER SELF ADHERED FLASHING FOR PENETRATIONS AND NON-VERTICAL SURFACES, MINIMUM 25 MILS THICK AND COMPATIBLE WITH WRB SURFACE WOOD OR LIGHT GAUGE METAL STUDS SCALE: 1/2” = 1’ - 0” STANDARD 3 COAT STANDARD STUCCO FINISH W/ DRAINAGE MEDIUM USING OX WALL SHEATHING INSTALLED AS WRB WEEP SCREED AT BASE OF WALL PER MANUFACTURER’S RECOMMENDATIONS & PCA RECOMMENDATIONS FLOOR & FOUNDATION SYSTEM 2X TREATED WOOD SILL PLATE SELF ADHERED STRAIGHT FLASHING (SEE NOTE ABOVE) OX THERMO-PLY, STYROFOAM SIS OR ISO RED ci EXTERIOR SHEATHING INSTALLED AS A WATER RESISTIVE BARRIER PER INSTALL INSTRUCTIONS- OX THERMO-PLY RED OR BLUE (WITH OR WITHOUT OX ISO RED ci OVERSHEATH) - OX STYROFOAM SIS OX THERMO-PLY OR SIS INSTALLED AS A WRB & A STRUCTURAL SHEATHING AS PER INSTALL INSTRUCTIONS STANDARD 3 COAT STANDARD STUCCO FINISH WITH DRAINAGE MEDIUM USING OX WALL SHEATHING INSTALLED AS A WEATHER RESISTIVE BARRIER OX ENGINEERED PRODUCTS WWW.OXENGINEEREDPRODUCTS.COM Date: 04/01/2014 Scale: 1/2” = 1’-0” DRAWN BY: DA Sketch Number OX-101 DETAIL TRADITIONAL 3 HARD-COAT STUCCO INSTALLED IN ACCORDANCE WITH THE MANUFACTURER’S OR THE PORTLAND CEMENT ASSOC. (PCA) RECOMMENDATIONS CONTROL JOINTS PER DRAWING, SPECS & PCA RECOMMENDATIONS

CONTROL JOINTS PER EXPANDED METAL LATH (ASTM …...expanded metal lath (astm c847), 3.4#sy, self furred or woven wire (astm c1032), or welded wire (astm c933), 17 ga w/ openings not

  • Upload
    others

  • View
    15

  • Download
    0

Embed Size (px)

Citation preview

Page 1: CONTROL JOINTS PER EXPANDED METAL LATH (ASTM …...expanded metal lath (astm c847), 3.4#sy, self furred or woven wire (astm c1032), or welded wire (astm c933), 17 ga w/ openings not

EXPANDED METAL LATH (ASTM C847), 3.4#SY, SELF FURRED OR WOVEN WIRE (ASTM C1032), OR WELDED WIRE (ASTM c933), 17 ga W/ OPENINGS NOT TO EXCEED 1.5IN. - LATH ACCESSORIES (ASTM C653) STRUCTURALLY ATTACH LATH OR WIRE TO WALL FRAMING SUPPORTS EVERY 7 INCHES (MAXIMUM) VERTICALLY UP THE STUD. ADDITIONAL INTERMITTENT FASTENING TO SHEATHING TO SMOOTH OUT DRAPING IS PERMITTED

SECOND LAYER OF WATER-RESISTIVE (BOND BREAK) BARRIER WITH A PERFORMANCE AT LEAST EQUIVALENT TO GRADE "D" BUILDING PAPER SELF ADHERED FLASHING FOR PENETRATIONS AND NON-VERTICAL SURFACES, MINIMUM 25 MILS THICK AND COMPATIBLE WITH WRB SURFACE

WOOD OR LIGHT GAUGE METAL STUDS

SCALE: 1/2” = 1’ - 0”

STANDARD 3 COAT STANDARD STUCCO FINISH W/ DRAINAGE MEDIUM USING OX WALL SHEATHING INSTALLED AS WRB

WEEP SCREED AT BASE OF WALL PER MANUFACTURER’S RECOMMENDATIONS & PCA RECOMMENDATIONS

FLOOR & FOUNDATION SYSTEM

2X TREATED WOOD SILL PLATE

SELF ADHERED STRAIGHT FLASHING(SEE NOTE ABOVE)

OX THERMO-PLY, STYROFOAM SIS ORISO RED ci EXTERIOR SHEATHING INSTALLED AS A WATER RESISTIVE BARRIER PER INSTALL INSTRUCTIONS- OX THERMO-PLY RED OR BLUE (WITH OR WITHOUT OX ISO RED ci OVERSHEATH) - OX STYROFOAM SIS OX THERMO-PLY OR SIS INSTALLED AS A WRB & A STRUCTURAL SHEATHING AS PER INSTALL INSTRUCTIONS

STAN

DARD

3 C

OAT

STA

NDA

RD S

TUCC

O F

INIS

H W

ITH

DRAI

NAG

E M

EDIU

M U

SIN

G O

X W

ALL

SHEA

THIN

G IN

STAL

LED

AS A

WEA

THER

RES

ISTI

VE B

ARRI

ER

OX

EN

GIN

EER

ED P

RO

DU

CTS

WWW.OXE

NGINEE

REDP

RODU

CTS.CO

M

Date

: 04/

01/2

014

Scal

e: 1

/2”

= 1’

-0”

DRAW

N B

Y: D

A

Sket

ch N

umbe

r

OX-

101

DET

AIL

TRADITIONAL 3 HARD-COAT STUCCO INSTALLED IN ACCORDANCE WITH THE MANUFACTURER’S OR THE PORTLAND CEMENT ASSOC. (PCA) RECOMMENDATIONS

CONTROL JOINTS PER DRAWING, SPECS & PCA RECOMMENDATIONS