7
SOYAL ACCESS CONTROL SYSTEM ® AR-401-IO-0808R-U2 V200619 Reset LINK TxRx LED BUSY LCD ACT 1 ON 2 1 6 5 4 3 2 1 1 1 1 1 1 1 1 1 1 1 1 2 2 2 2 2 5 5 4 4 3 3 2 2 1 1 2 2 2 2 2 2 2 3 3 3 3 3 3 3 3 Relay K1 Relay K4 Relay K2 Relay K5 Relay K3 Relay K6 Relay K7 Relay K8 PORT 2 PORT 1 CN5 UART CN6 CN7 CN8 CN9 CN10 CN16 CN17 CN18 CN15 CN14 CN13 CN11 CN12 JV+ JV- AR-401-IO-0808R-U2 Contents Features 1 Product Specification PIN Assignments 32 bits/72MHz ARM CPU, upgrade serial device to TCP/IP device Dual UART port supported and 4K/4K Rx/Tx buffer. 10/100 Mbps Base T Etherent Independent power supply design for I/O Optical coupling isolation for Digital Inputs Two DI for Indepentant Positive Trigger & Negtivie Trigger High power output Relay directly trig high-load device POE module is optional Type Input Voltage Power Consumption Dimensions Port 1 Port 2 RS-485 Transmission Interface Active Distance Surge protection N.W.(g) Thunder Protection Data Bits Stop Bits Parity Check Baudrate Protocol Software Configuration Operating Temperature Operating Humidity DI input DO relay output POE (optional) Ethernet to Serial Port Device 12 VDC (±5%) <2W Panel Mounting Base : 130(L)x175(W)x32(H) RS-485 (A+, B-) RS-485 (A+, B-) - 10/100M Base T Ethernet RS-485 300M/RS-485 16KV 86±5 1.5KV 7, 8 1, 2 None, Even, Odd 4800-115200 bps ARP, IP, TCP Client, UDP, ICMP, HTTP, DHCP, NetBIOS, SNMP V1, V2, V3, Web Console -20~+755 to 95% RH Positive Trigger or Negtitive Trigger 240VAC/10A , 240VDC /10A POS needs to provide more than 12V / 2W power Function DI/DO Power Supply (DC12V/1W) Function Main Power Supply(Dual Power Mode) (DC12-24V/1W) Main Power Supply (Single Power Supply Mode) (DC12V/1W) Function External Port 1 (RS-485 input) Function External port 2 (RS-485 input) Function Relay output K1~K8 Pin 1 2 Pin 1 2 1 2 Pin 1 2 Pin 1 2 Pin 1 2 3 Description V12 V0 Description V12-24 V0 V12 V0 Description B- A+ Description B- A+ Description N.O. COM N.C. CN17 CN18 CN5~CN12 CN14 CN13 CN15 CN16 Function DI input Function DI input Pin 1 2 3 4 5 Pin 1 2 3 4 5 Description COM DI.4 DI.3 DI.2 DI.1 Description COM DI.8 DI.7 DI.6 DI.5 POE Module AR-401-IO-0808R-U2

Contents Features - SoyalSOYAL ACCESS CONTROL SYSTEM ® AR-401-IO-0808R-U2 V200318 Web Console Set up IP Address: 3. Login Type "User name" & "Password" on the pop up login window

  • Upload
    others

  • View
    5

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Contents Features - SoyalSOYAL ACCESS CONTROL SYSTEM ® AR-401-IO-0808R-U2 V200318 Web Console Set up IP Address: 3. Login Type "User name" & "Password" on the pop up login window

SOYALACCESS CONTROL SYSTEM

® AR-401-IO-0808R-U2V200619

Reset LINK

TxRx

LED BU

SYLC

D AC

T

1

ON

2

1

654321

1 1 1 1

1 1 1 1 1 1 12

2 2 2 2 5 54 43 32 21 1

2 2 2 2 2 2 23 3 3 3 3 3 3 3

RelayK1

RelayK4

RelayK2

RelayK5

RelayK3

RelayK6

RelayK7

RelayK8

PORT 2PORT 1

CN5

UART

CN6 CN7 CN8 CN9 CN10

CN16 CN17 CN18 CN15 CN14 CN13

CN11 CN12

JV+JV-

AR-401-IO-0808R-U2

Contents Features1 Product

Specification

PIN Assignments

32 bits/72MHz ARM CPU, upgrade serial device to TCP/IP deviceDual UART port supported and 4K/4K Rx/Tx buffer.10/100 Mbps Base T EtherentIndependent power supply design for I/O Optical coupling isolation for Digital InputsTwo DI for Indepentant Positive Trigger & Negtivie TriggerHigh power output Relay directly trig high-load devicePOE module is optional

Type

Input Voltage

Power Consumption

Dimensions

Port 1

Port 2

RS-485 Transmission

Interface

Active Distance

Surge protection

N.W.(g)

Thunder Protection

Data Bits

Stop Bits

Parity Check

Baudrate

Protocol

Software Configuration

Operating Temperature

Operating Humidity

DI input

DO relay output

POE (optional)

Ethernet to Serial Port Device

12 VDC (±5%)

<2W

Panel Mounting Base : 130(L)x175(W)x32(H)

RS-485 (A+, B-)

RS-485 (A+, B-)

-

10/100M Base T Ethernet RS-485

300M/RS-485

16KV

86±5

1.5KV

7, 8

1, 2

None, Even, Odd

4800-115200 bps

ARP, IP, TCP Client, UDP, ICMP, HTTP, DHCP, NetBIOS, SNMP V1, V2, V3,

Web Console

-20℃~+75℃

5 to 95% RH

Positive Trigger or Negtitive Trigger

240VAC/10A , 240VDC /10A

POS needs to provide more than 12V / 2W power

FunctionDI/DO Power Supply(DC12V/1W)

FunctionMain Power Supply(Dual Power Mode)(DC12-24V/1W)

Main Power Supply (Single Power Supply Mode)(DC12V/1W)

FunctionExternal Port 1 (RS-485 input)

FunctionExternal port 2(RS-485 input)

FunctionRelay output K1~K8

Pin12

Pin

1

2

1

2

Pin12

Pin12

Pin123

DescriptionV12V0

Description

V12-24

V0

V12

V0

DescriptionB-A+

DescriptionB-A+

DescriptionN.O.COMN.C.

CN17

CN18

CN5~CN12

CN14 CN13

CN15

CN16

FunctionDI input

FunctionDI input

Pin12345

Pin12345

DescriptionCOMDI.4DI.3DI.2DI.1

DescriptionCOMDI.8DI.7DI.6DI.5

POEModule

AR-401-IO-0808R-U2

Page 2: Contents Features - SoyalSOYAL ACCESS CONTROL SYSTEM ® AR-401-IO-0808R-U2 V200318 Web Console Set up IP Address: 3. Login Type "User name" & "Password" on the pop up login window

V200619

Reset

7 6 5 4 3 2 17 6 5 4 3 2 1

CH2

K1 K2 K3 K4 K5 K6 K7 K8

CH1 DI/DOPower

DI1~4 DI5~8Power

JV+JV-

Cloud

B-

DI.4

DI.3

DI.2

DI.1

COM

DI.8

DI.7

DI.6

DI.5

COM

A+B-

A+

Vin+

Vin+Vin-

N.O

.

N.C

.COM

N.O

.

N.C

.COM

N.O

.

N.C

.COM

N.O

.

N.C

.COM

N.O

.

N.C

.COM

N.O

.

N.C

.COM

N.O

.

N.C

.COM

N.O

.

N.C

.COM

Vin-

6 5 4 3 2 1

AR-401-IO-0808R-U2

Ethernet

UART

CN16

CN5 CN6 CN7 CN8 CN9

CN17 CN18 CN15 CN14

CN10 CN11 CN12

CN13

DI1

DI5

DI2

DI6

DI3

DI7

DI4

DI8

A+A+ B-B-

Serial-to-Ethernet Server with I/O Module10/ 100 Base-T

Wiring Diagram

Power Supply Mode

Wiring for Positive / Negtive Trigger

When DI COM is connected to POWER I / O DC12V-, DI-Reference is POWER I / O DC12V +.When DI COM is connected to POWER I / O DC12V +, DI-Reference is POWER I / O DC12V-.

Dual Power Supply Mode (JV+ & JV- Open Circuit):Two independent power supplies are required. In this mode, the main controller and I / O operate in power isolation mode to improve system safety and reliability. The main power supply can be selected from 12-24VDC, but the I / O side The power supply must be powered by 12VDC.

Single Power Supply Mode (JV+ & JV- Short Circuit):Only reqire one set of power supply, which is convenient for installation in small systems without power isolation. In this mode, the power supply is 12V

Single/Dual Power Supply Mode Selection:

JV+JV-

JV+JV-

RS485 Serial Device RS485 Serial Device

PowerSupply

9-24VDC

Negtive Trigger Positive Trigger

*JV+ & JV- both do not plug in jumper

*JV+ & JV- both plug in jumper

Page 3: Contents Features - SoyalSOYAL ACCESS CONTROL SYSTEM ® AR-401-IO-0808R-U2 V200318 Web Console Set up IP Address: 3. Login Type "User name" & "Password" on the pop up login window

SOYALACCESS CONTROL SYSTEM

® AR-401-IO-0808R-U2V200619

Web ConsoleSet up IP Address:

3. Login

Type "User name" & "Password" on the pop up login window.

※ Factory Default :User name: SuperAdmPassword: 721568

1.Connect the device to a computer, Then turn on your Web Browser and type "http://192.168.1.127" on IP address to start web console.

※http://192.168.1.127 is the factory default, if the IP address has been changed, the new IP address may be entered.

2. When you type the IP address, you will see the [Current State] page.。

The version of ISP Firmware

Current IP address

Main Menu

SuperAdm

721568

Page 4: Contents Features - SoyalSOYAL ACCESS CONTROL SYSTEM ® AR-401-IO-0808R-U2 V200318 Web Console Set up IP Address: 3. Login Type "User name" & "Password" on the pop up login window

V200619

Serial-to-Ethernet Server with I/O Module10/ 100 Base-T

4. Click on [Network Setting] on Main Menu to set up new IP address.

a.Type the new IP address

d.Click it to update

5. Click on [User Password] on Main Menu to change

Type the new User Name & Password.

b.Type the new LAN Net Maskc.Type the new Default Gateway

6. Click on [Channel 1 Setting] or [Channel 2 Setting] on Main Menu to set the port.

Set the [Operation Mode] at the [Server] or the [Client].At the [Server]: [Remote Port] need to be set [0].At the [Client]: [Remote Port] need to be set as the server port.At the [Server]: [Remote IP] need to be set [0.0.0.0].At the [Client]: [Remote IP] need to be set as the server IP address.[UART to NET minimum bytes]: Proposes to set more than 900.

Page 5: Contents Features - SoyalSOYAL ACCESS CONTROL SYSTEM ® AR-401-IO-0808R-U2 V200318 Web Console Set up IP Address: 3. Login Type "User name" & "Password" on the pop up login window

SOYALACCESS CONTROL SYSTEM

® AR-401-IO-0808R-U2V200619

7. Set up I/O: Click on [Direct Control IO 0~3]

8. Set up I/O: Click on [Direct Control IO 4~7]

Status Indicate for Digital Inputs (DI0~3) and Digital Outputs (DO0~3)

Status Indicate for Digital Inputs (DI4~7) and Digital Outputs (DI4~7)

Status Control for Digital Outputs (DO0~3)

Status Control for Digital Outputs (DI4~7)

Page 6: Contents Features - SoyalSOYAL ACCESS CONTROL SYSTEM ® AR-401-IO-0808R-U2 V200318 Web Console Set up IP Address: 3. Login Type "User name" & "Password" on the pop up login window

V200619

Serial-to-Ethernet Server with I/O Module10/ 100 Base-T

Update the ISP Firmware

Step 1:Execute the software [ UdpUpdater.exe] that

please login the SOYAL website to download

Step 2: Type IP Address

Step 4: 【Load F/W】open the documents that have the new ISP Firmware

Step 5: Click the new ISP Firmware, for example【APX727i3_V0409 8I8O190903.STM】and click【Open】

Step 3: Select Device [ 727iV3]

Step 6: Click 【Update F/W】to start the firmware update

Step 7: Done when the screen shows "Scan Completed". Click 【Exit】to finish.

Way 1: Normal Ethernet Connection

Page 7: Contents Features - SoyalSOYAL ACCESS CONTROL SYSTEM ® AR-401-IO-0808R-U2 V200318 Web Console Set up IP Address: 3. Login Type "User name" & "Password" on the pop up login window

SOYALACCESS CONTROL SYSTEM

® AR-401-IO-0808R-U2V200619

Step8

Step6

Step5

Step3

Step4

Step1

Step7

Step 2: Execute 【 UdpUpdater.exe】that please login the SOYAL website to download

Step 1: Entering Boot Load Mode Cut off the power supply--> pressing the “Reset” button for a hold and then repower at the same time until BUSY/ACT led turns ON and keep blinking.

Step 3: Click on 【Range Scan】to generate a set of IP address, double click to auto key-in this address to Ethernet IP box

Step 4: 【Load F/W】open the documents that have the new ISP Firmware

Step 5: Click the new ISP Firmware, for example 【APX727i3_V0409 8I8O190903.STM】and click【Open】

Step 6: Select Device 【727iV3】

Step 7: Click 【Update F/W】to start the firmware update

Step 8: Done when the screen shows "Scan Completed". Click 【Exit】to finish.

Way 2 : Entering Boot Load Mode (When the 401-IO-0808R-U2 program does not work, you can use this method to re-download)