© 2013 Cisco and/or its affiliates. All rights reserved. 1
Cisco Support Community Expert Series Webcast:
Configuration, Design, and Troubleshooting of Cisco Nexus 1000
Louis Watta @mc68881rc Technical Leader
June 4, 2013
2 © 2013 Cisco and/or its affiliates. All rights reserved.
• Today’s featured expert is Cisco Support Engineer Expert
• Ask him questions now about Cisco Nexus 1000v
Louis Watta
Technical Leader in TS Incubation
3
Panel of Experts
Event Date: June, 2013
Robert Burns
Technical Leader Steve Winters
Customer Support Engineer
4 © 2013 Cisco and/or its affiliates. All rights reserved.
Today’s presentation will include audience polling questions
We encourage you to participate!
5 © 2013 Cisco and/or its affiliates. All rights reserved.
If you would like a copy of the presentation slides, click the PDF link in the chat box on the right or go to
https://supportforums.cisco.com/community/netpro/data-center/unified-computing
Or, https://supportforums.cisco.com/docs/DOC-33836
6 © 2013 Cisco and/or its affiliates. All rights reserved.
Our panel of experts will be answering them later in the webcast
7 © 2013 Cisco and/or its affiliates. All rights reserved.
a) Nexus 1000V what is it?
b) I’ve heard of Nexus 1000V but not deployed it
c) I’ve played with it in a lab environment
d) I’m running it in production.
What is your level of experience with Nexus 1000v?
8 © 2013 Cisco and/or its affiliates. All rights reserved.
Configuration, Design, and Troubleshooting of Cisco Nexus 1000
Technical Leader
June 4, 2013
Louis Watta
9 © 2013 Cisco and/or its affiliates. All rights reserved.
• Current Nexus 1000V Releases and New Features
• Licensing
• Virtual Supervisor Module (VSM)
• Virtual Ethernet Module (VEM)
• Upgrades
• Cisco Nexus 1x10
10 © 2013 Cisco and/or its affiliates. All rights reserved.
11 © 2013 Cisco and/or its affiliates. All rights reserved.
• 5.2(1)SM1(5.1) Hyper-V only
Support for SCVMM 2012 SP1 and Windows Server 2012
• 4.2(1)SV2(1.1) - 2.1
New Features including VCPlugin, Vtracker
Cisco Trustsec Support (CTS)
License changes for Essential(free) and Advanced
• 4.2(1)SV1(5.x) - 1.5.x
1.5, 1.5.1a, and 1.5.2
1.5.2 first version to support ESXi 5.1
12 © 2013 Cisco and/or its affiliates. All rights reserved.
• License Changes
Essential (free)
Advanced (licensed)
• Cisco TrustSec Support
• vTracker
• VCPlugin
• VSM HA improvements
• VSMs split between Datacenters
• VEM remote branch support
• Enhanced Installer
• Enhanced Upgrades
Allows for configuration changes even if VSM is higher rev than VEM
13 © 2013 Cisco and/or its affiliates. All rights reserved.
• Increased Scale
128 VEM support per VSM
300 ports per host
4000+ ports per VSM
• VXLAN Evolution
Unicast mode
No multicast configuration required
Mac-address distribution
• VXLAN Gateway
14 © 2013 Cisco and/or its affiliates. All rights reserved.
• Openstack support
• KVM and XEN support
• Increase configuration limits
Even more increase in configuration limits
• Citrix NetScaler on Nexus 1110
• Imperva WAF on Nexus 1110
15 © 2013 Cisco and/or its affiliates. All rights reserved.
16 © 2013 Cisco and/or its affiliates. All rights reserved.
• All features but…
Cisco TrustSec (CTS)
DHCP snooping
IP Source Guard
Dynamic ARP Inspection
• You get 512 socket license
No expiration
• Default mode on new install
• Support Options
Pay Nothing – support is through the communities site off cisco.com
https://communities.cisco.com/community/technology/datacenter/nexus1000v
Pay for service contract
Cost is $39 per socket, per year for TAC support.
17 © 2013 Cisco and/or its affiliates. All rights reserved.
• For customers that want more security features
• Required for VSG
• Existing customers with licenses will be considered Advanced
No requirement to use Advanced mode
• Licensed customers can get Virtual Security Gateway(VSG) for free
Account team can submit request
Note VSG will no longer be sold separately
18 © 2013 Cisco and/or its affiliates. All rights reserved.
• Extra licenses to use in temporary situations
• 16 extra sockets
Sometimes more depending on number of licenses you’ve purchased
• Can only be used after a valid license is installed
• Not easy to tell which VEM is using an overdraft license
19 © 2013 Cisco and/or its affiliates. All rights reserved.
a) Essentials
b) Advanced
c) Not Sure
Which Licensing version do you think you will deploy?
20 © 2013 Cisco and/or its affiliates. All rights reserved.
21 © 2013 Cisco and/or its affiliates. All rights reserved.
• What is the Virtual Supervisor Module (VSM)
• Planning
• Installation
• Troubleshooting
22
Hypervisor Hypervisor Hypervisor
Modular Switch
…
Linecard-N
Supervisor-1 (Active)
Supervisor-2 (StandBy)
Linecard-1
Linecard-2
Ba
ck P
lan
e
VEM-N VEM-1 VEM-2
VSM: Virtual Supervisor Module
VEM: Virtual Ethernet Module
VSM-1 (active)
VSM-2 (standby)
Virtual Appliance
Network
Admin
Server
Admin
NX-OS
Control Plane
NX-OS
Data Plane
23 © 2013 Cisco and/or its affiliates. All rights reserved.
• VSM is a Virtual Machine
On ESXi
On Nexus 1x10
Hyper-V
• Control plane for the Nexus 1000V solution
• Responsible for
Programming and managing Virtual Ethernet Modules (VEM)
Communicating with Management Applications
VMware vCenter
Microsoft SCVMM 2012 SP1
• 1 VSM HA pair can manage 64 VEMs
• Coexist with VMware vSwitch, vDS, Microsoft Logical, Native Switch
24 © 2013 Cisco and/or its affiliates. All rights reserved.
• VSM is all Hyper-V or all ESXi VEM modules
No mixing of VEM modules currently allowed
• VSM can run anywhere
VSM attached to Hyper-V VEMs can run on ESXi
Nothing specific to the VSM VM to require it to run on a specific hypervisor
• Configs are slightly different
25 © 2013 Cisco and/or its affiliates. All rights reserved.
• Support the VSM on a VEM
• Support the VSM on any hypervisor native, logical, or distributed switch
• Support the VSM on any supported hypervisor (ESXi/Hyper-v)
• Keep VSMs on different hypervisor hosts
Use anti-affinity rules
• Storage wise we don’t care.
VSM can be hosted on network storage
26
hypervisor
VEM-2
VM VM VM
VSM
hypervisor
VEM-1
VM VM VM
VSM
hypervisor
VEM-2
VM VM VM
VSM
hypervisor
VEM-1
VM VM VM
VSM
vSwitch vSwitch
hypervisor
VEM-2
VM VM VM
hypervisor
VEM-1
VM VM VM
hypervisor
vSwitch
VM VM VM
VSM
Management Cluster
Data Cluster
VSMs on VEM VSMs on vSwitch
VSMs in Mgmt Cluster
27
• VSMs and VEMs spread across Datacenters
• VSMs can be split across DCs
New with 2.1
Requires L2 connectivity across DCI
10ms latency across DCI
• Not Supported with Hyper-V
Supported in a later release
VSM
VSM
hypervisor
VEM-1
VM VM VM
Local DC
hypervisor
VEM-2
hypervisor
VEM-4
VM VM VM
hypervisor
VEM-3
VM VM VM
Remote DC
VM VM
DCI
VM
28 © 2013 Cisco and/or its affiliates. All rights reserved.
• VSM on a Nexus 1010/X or 1110-S/X
It’s still a Virtual Machine
Up to 10 VSMs on one 1110-X
• Always deploy in pairs!
• 1x10 allows for Network team to own the virtualization platform
• 1x10s should go in the Aggregation Layer
• Stretched Model requires
L2 Connectivity
10ms latency
No Hyper-V support
29 © 2013 Cisco and/or its affiliates. All rights reserved.
• L3 Mode
We recommend L3 and it’s the default mode now
Easier to troubleshoot
Flexible
Requires an IP address be assigned to the VEM
Uses UDP port 4785 for both source and destination
• L2 mode
Requires L2 connectivity through Control interface to all VEM modules
L2 still supported on ESX
Not supported with Hyper-V
30 © 2013 Cisco and/or its affiliates. All rights reserved.
• Two options for the L3 control interface
Mgmt 0 (default)
Control 0
• Recommend mgmt 0
• Use control 0
To separate control and management traffic
• Mgmt and Control use different VRF
Mgmt 0 uses VRF management
Control 0 uses VRF default
• Primary and secondary VSM still need to be L2 adjacent
31
• For new installations use the Installer application
ESXi and Hyper-V
• ESXi
Installer can also migrate ESXi hosts to the N1KV
ISO and OVA still available Use for established VMware vSphere deployments
• Hyper-V
Installer or Template/ISO install methods
• Save inputs to a config file
32 © 2013 Cisco and/or its affiliates. All rights reserved.
• VSM connects to vCenter using SSL connection
Plugin that contains SSL cert
Unique extension ID for the VSM
• VSM talks to vCenter using its API
We push and pull data to/from vCenter
• VSMs get tied to a VMware Datacenter
Multiple VSMs tied to same DC is allowed
Can get confusing
33 © 2013 Cisco and/or its affiliates. All rights reserved.
• If you get “Extension key was not registered before it’s use”
Re-register the Extension Key with VMware vCenter
• If you get “Connection refused. connect failed in tcp_connect()”
VMware admin could have changed the http port
API communication is through port 80 with VMware vCenter
Find new port and change it on VSM
34 © 2013 Cisco and/or its affiliates. All rights reserved.
• Extension gets installed on SCVMM via a Provider Extension
Simple Windows installable file
• SCVMM pulls data from the VSM using our API
VSM has a REST API now
SCVMM pulls data once every 30 minutes (yes 30 minutes)
You can manually force a refresh in SCVMM
• VSMs get tied to a SCVMM Host Group
Multiple VSMs tied to same Host Group is allowed
35 © 2013 Cisco and/or its affiliates. All rights reserved.
• No persistent connection between VSM and SCVMM
Manually refresh through SCVMM to update
• Any connectivity errors should show in the “Jobs” Screen
• Verify Connectivity by accessing API from SCVMM host
http://<vsm-ip>/api/n1k
Remember to add admin credentials to SCVMM run-as accounts
Currently API can use local accounts only
Verify any proxies or firewalls
• If the extension does not show in SCVMM re-install the provider
36 © 2013 Cisco and/or its affiliates. All rights reserved.
• VSM requires 4GB RAM
• No stretched deployment support
Even with Nexus 1010/1110
Coming in later release
• Recommend VSM be on Microsoft Native vSwitch
• 64 VEM support, 2k veth ports
• Domain ids shrink from 4k to 1k
NXOS 5 issue
• L3 Control mode only
37 © 2013 Cisco and/or its affiliates. All rights reserved.
• L3 control is the preferred method
• Use mgmt 0 for control
• Primary and Standby VSM in same L2 domain!!!
Required even if VSMs are split between datacenters
• VSM on VEM is supported
• VSM primary to secondary latency max 10ms
10ms even for VSMs split between datacenters
• VSM to VEM latency 5-10ms
For VEMs at branch locations 100ms
• Use the clone option to backup your VSM!!
38 © 2013 Cisco and/or its affiliates. All rights reserved.
39 © 2013 Cisco and/or its affiliates. All rights reserved.
• Again we recommend L3 Control
• L3 control requires a VMKernel NIC
We need an L3 interface to forward control traffic
• Recommend using the ESXi management vmkernel nic
Requires you migrate the management interface to the VEM
Doesn’t require static routes on ESXi hosts
• Don’t create an L3 Vmkernel nic on same subnet as mgmt Vmkernel nic
40
• Don’t use multiple VMKs on the same subnet but virtual switches
• VMware uses a single TCP/IP stack for all VMK interfaces
• No way to direct traffic up a particular interface when they share the same subnet
• One interface gets picked for all traffic on that subnet
• Check out VMware KB article 2010877
VMware ESX
VEM-1
VMK1
192.168.10.200
VMK0
192.168.10.100
vSwitch
41 © 2013 Cisco and/or its affiliates. All rights reserved.
• VMware Update Manager(VUM) does all the work
• Requires HTTP server on the VSM
• Turn off the following VMware cluster settings
HA, DRS, and DPM
5.1 Seems to do this automatically
• VUM Logs on vCenter Server in
C:\Documents and Settings\Application Data\All Users\VMware\VUM\logs
• VEM modules get stored in
C:\ProgramData\VMware\VMware Update Manager\Data\hostupdate
CISCO directory comes from VSM
CSCO directory comes from VUM portal
Uninstalling VUM does not clean out the above directories
42 © 2013 Cisco and/or its affiliates. All rights reserved.
• With ESXi 5 use esxcli
Can be run remote or locally on the host
Local
esxi5.0# esxcli software vib install –v http://<VSM-IP-
Address>/cisco/vibs/VEM/4.1.0/VEM-4.1.0-patch01/cross_cisco-vem-v140-4.2.1.1.5.1.0-
3.0.1.vib
Remote
linux1# esxcli --server <server> software vib install -v http://<VSM-IP-
Address>/cisco/vibs/VEM/4.1.0/VEM-4.1.0-patch01/cross_cisco-vem-v140-4.2.1.1.5.1.0-
3.0.1.vib
• ESX/ESXi 4.1
Esxupdate (local)
esx4.1# esxupdate –b cross_cisco-vem-v140-4.2.1.1.5.1.0-2.0.1.vib update
Vihostupdate (remote)
linux1# vihostupdate –install –bundle cisco-vem-v140-4.2.1.1.5.1.0-2.0.1.zip --server
<server>
43
• Uses VUM or httpClient
• Tries VUM first
• httpClient needs to be enabled on every ESXi host
• Requires administrator privileges to the ESXi host
• VSM must be connected to vCenter
44 © 2013 Cisco and/or its affiliates. All rights reserved.
• VMware introduced Stateless ESXi with version 5
• ESXi PXE boots
• No information is stored on local disks
No place to install the VEM and store opaque data
• VEM module has to be built into the boot image
• Possible using VMware PowerCLI
• Instructions are in Install and Upgrade Guide
http://www.cisco.com/en/US/docs/switches/datacenter/nexus1000/sw/4_2_1_s_v_1_5_1/install_upgrade/vsm_vem/guide/n1000v_installupgrade.html
45 © 2013 Cisco and/or its affiliates. All rights reserved.
• Only L3 supported
• No special NIC required
• We talk to the Windows Server 2012 Management NIC
Management NIC can be assigned to a physical nic
Virtual NIC attached to Microsoft native or logical switch
Not recommended to connect Management NIC to VEM
• No special port-profile required
• Very easy configuration
46 © 2013 Cisco and/or its affiliates. All rights reserved.
• VEM is a simple Windows installation
• Manually double click the msi file and install
• SCVMM will automatically install VEM if it’s not manually installed
• Upgrades will leverage Windows Server Update Services (WSUS)
47
• VMK interface created on ESXi host
• Can the ESXi host ping the VSM control/mgmt interface
• Static route needed?
• Uplink profile created correctly
• L3 veth port-profile created correctly
• Check the opaque data
48 © 2013 Cisco and/or its affiliates. All rights reserved.
• Can you ping the control interface of the VSM?
~ # esxcfg-vmknic -l
Interface Port Group/DVPort IP Family IP Address Netmask Broadcast MAC Address MTU
TSO MSS Enabled Type
vmk0 VMkernel IPv4 172.18.217.180 255.255.255.0 172.18.217.255 00:18:fe:72:f2:aa 1500
65535 true STATIC
vmk2 34 IPv4 192.168.11.180 255.255.255.0 192.168.11.255 00:50:56:78:6f:52 1500
65535 true STATIC
ESXi VMK interfaces are special interfaces
Need to be created by VMware Admin
~ # vmkping 192.168.11.10
PING 192.168.11.10 (192.168.11.10): 56 data bytes
64 bytes from 192.168.11.10: icmp_seq=0 ttl=255 time=0.570 ms
64 bytes from 192.168.11.10: icmp_seq=1 ttl=255 time=0.420 ms
Verify Connectivity
49 © 2013 Cisco and/or its affiliates. All rights reserved.
• Only one default gateway is allowed by ESXi
Usually used by the VMK being used for management access
• Remember ESXi host 1 was using VMK 192.168.10.154
It needs to talk to 192.168.11.10
Requires a static route be defined
• Just like linux
route add –net 192.168.11.0 netmask 255.255.255.0 gw 192.168.10.1
• This is why we recommend moving mgmt and using it for VEM
50
• Check SVS domain parameters n1kv-l3# show svs domain
SVS domain config:
Domain id: 43
Control vlan: 1
Packet vlan: 1
L2/L3 Control mode: L3
L3 control interface: control0
• Verify control 0 n1kv-l3# show run int control 0
interface control0
ip address 192.168.11.10/24
• Verify VRF default n1kv-l3# show ip route
IP Route Table for VRF "default"
0.0.0.0/0, ubest/mbest: 1/0, pending
*via 192.168.11.1, control0, [1/0], 4d23h,
static
• Can the VSM ping the VMK interface n1kv-l3# ping 192.168.11.180 vrf default
PING 192.168.11.180 (192.168.11.180): 56 data
bytes
64 bytes from 192.168.11.180: icmp_seq=0 ttl=63
time=1.082 ms
64 bytes from 192.168.11.180: icmp_seq=1 ttl=63
time=0.841 ms
51 © 2013 Cisco and/or its affiliates. All rights reserved.
• Uplink needs to allow VLANs 10 and 11
• VLANs 10 and 11 need to be system vlans
n1kv-l3# show run port-profile uplink
port-profile type ethernet uplink
vmware port-group
switchport mode trunk
switchport trunk allowed vlan 10-11,150-152
channel-group auto mode on mac-pinning
no shutdown
system vlan 10-11
state enabled
52 © 2013 Cisco and/or its affiliates. All rights reserved.
• VMK1 interface needs to be migrated to this port-profile
• It must have capability l3control and system vlan n1kv-l3# show run port-profile L3-control-vlan11
port-profile type vethernet L3-control-vlan11
capability l3control
vmware port-group
switchport mode access
switchport access vlan 11
no shutdown
system vlan 11
state enabled
• Each VMK1 VLAN needs a new port-profile
So create another for VLAN 10
• VSM will not allow VMs to connect to this port-profile
VMK interfaces only
53 © 2013 Cisco and/or its affiliates. All rights reserved.
• Quite a bit simpler
• Verify SCVMM can talk to VSM
Verify API reachability
Check for proxies/firewalls
• Verify Logical Switch Compliance
Switch compliance can get out of whack
Verify compliance and remediate if necessary
• Restart the Nexus1000v Service
Restart the process on the Hyper-V Host
54 © 2013 Cisco and/or its affiliates. All rights reserved.
• Use L3 Control
• Use ESXi mgmt vmk interface for control
• Control network should have low latency and available bandwidth
10ms for local DC
100ms for branch office deployment
• On UCS make Service Profile does not contain “Dynamic VNICs”
VEM and VM-FEX are mutually exclusive
55 © 2013 Cisco and/or its affiliates. All rights reserved.
56 © 2013 Cisco and/or its affiliates. All rights reserved.
• First always read and follow the upgrade guides
Go in order
• Take a backup of the VSMs
On ESXi/Hyper-V use the clone to template option
On Nexus 1x10s use the export function
Backup the running-config
• Generate a tech-support before the upgrade
• If something goes wrong STOP and call TAC
• Use a maintenance window
VEM upgrades require ESXi hosts to be in Maintenance Mode
57 © 2013 Cisco and/or its affiliates. All rights reserved.
Starting Version
1.4 1.5 2.1 Combined VMware upgrade
Notes
1.3 Yes Yes* Yes* No 1.4 last version to support ESX
4.0
1.4 Yes Yes No 1.4 last version to support ESX
4.0
1.5 Yes Yes**
• Upgrade matrix tool http://www.cisco.com/web/techdoc/n1kv/upgrade/utility/n1kvmatrix.html
* Must upgrade to 1.4 first
** Combined upgrade only supported from 1.5.2 to 2.1 and VMware vCenter 5.0U1 or later
58 © 2013 Cisco and/or its affiliates. All rights reserved.
• Allows you to upgrade N1KV VEM and ESXi at the same time
• Requirements
VSM and VEMs must be at 1.5.2 or higher
vCenter and VUM servers must be at 5.0 Update 1 or higher
• Steps
Upgrade VSM to 2.1
Create an upgrade ISO image including new VEM module for ESXi
Set up a VUM Baseline
Update bulletin ID from VSM
Initiate upgrade from vCenter on the ESXi host
59 © 2013 Cisco and/or its affiliates. All rights reserved.
• Changes from 2.1
You can now Upgrade VSMs and make changes without upgrading VEMs
• Upgrade is similar to other Nexus switches
Copy new kickstart and system images
Run “install all”
“install all” does the following
Upgrade/Reboot the Secondary VSM
Switchover to Secondary VSM – It’s now the active VSM with VEMs attached
Upgrade/Reboot the old-Primary VSM
Attach old-Primary VSM as Secondary
• Requires no outage of the VSM
60 © 2013 Cisco and/or its affiliates. All rights reserved.
• If something is wrong after the VSM upgrade STOP
Call TAC
Roll back using backup method
Shutdown the VSM VMs
Power-on the Clones (ESXi), Import the backup (Nexus 1x10)
• Sometimes the VEM won’t connect to the Standby VSM
Try a “system switchover” once the old primary is upgraded
• Might want to verify Standby VSM before upgrade
Make sure VEMs can connect to standby
Use “system switchover” command
61 © 2013 Cisco and/or its affiliates. All rights reserved.
• VEM module upgrade kicked off on VSM
If VUM is installed everything is automatic
VSM communicates with vCenter to manage the upgrade
Host is placed in maintenance mode(if DRS is installed VMs are migrated off)
VEM is upgraded and host exits maintenance mode
Moves on to the next host
If VUM is not installed
Still initiate the process on the VSM
User manually places ESXi hosts in maintenance mode
Upgrade the VEM with esxcli command
Exit maintenance mode and move to the next host
• Always complete the upgrade
Issue the “vmware vem upgrade complete” command
This signals vCenter to use the new VEM when hosts are added
62 © 2013 Cisco and/or its affiliates. All rights reserved.
• Remember the VMware admin has to acknowledge upgrade in vCenter
• Don’t upgrade the VEMs by pushing a baseline
• Make sure you have DRS capacity
Need to be able to handle one ESXi host failure
• If a particular ESXi host fails
It’s usually because the host cannot go into maintenance mode
From vCenter attempt to put the host in maintenance mode
Troubleshoot any issues that prevent it
If an ESXi host is running a vCenter VM this can cause problems
• You can restart the VEM upgrade after it fails
It will only upgrade hosts that did not succeed
63 © 2013 Cisco and/or its affiliates. All rights reserved.
64 © 2013 Cisco and/or its affiliates. All rights reserved.
• Based off UCS C2x0 server
Provide 6 x 1G network connections
1110-X 2 x 10G (not active in current code)
10G available only on purchase. No upgrade available
• Virtual Service Blade (VSB) Support
1010/1110-S supports 6
1010/1110-X supports 10
• Current supported VSBs
Nexus 1000V VSM
Virtual Security Gateway (VSG)
Network Analysis Module (NAM)
Data Center Network Manager (DCNM)
Imperva WAF
Citrix NetScaler
65 © 2013 Cisco and/or its affiliates. All rights reserved.
• Must be deployed in pairs
No option for standalone
• Deploy in the Aggregation Layer
• Must be in the same L2 domain for management and control
• Uses same HA mechanism as VSM with domain id and control vlan
Do not overlap the domain id between a 1x10 and a VSM
• Not supported
Primary and Secondary VSM on same 1x10
Primary VSM on ESX and Secondary VSM on 1x10 or vice versa
66 © 2013 Cisco and/or its affiliates. All rights reserved.
VSB Import/Export
• Works with VSM, NAM, and VSG
• Can Import/Export both primary and secondary
• Export requires that VSB be shutdown
• Images are stored in “export-import/” dir on bootflash
Can be manually copied off to remote storage
67 © 2013 Cisco and/or its affiliates. All rights reserved.
• Network traffic is classed into 3 categories
• Management
Carries the mgmt 0 interface of the 1x10
Carries the mgmt 0 traffic for all VSMs installed
• Control
Carries all the control and packet traffic for the VSMs installed on the 1x10
Carries control traffic for HA between primary and secondary 1x10
• Data
Used by Virtual Service Blades (VSB) other than VSM
• 5 Network Topologies you can choose
68 © 2013 Cisco and/or its affiliates. All rights reserved.
Uplink
Type
Management VLAN Control VLAN Data VLAN
1 Ports 1 and 2 Ports 1 and 2 Ports 1 and 2
2 Ports 1 and 2 Ports 1 and 2 Ports 3-6
3 Ports 1 and 2 Ports 3-6 Ports 3-6
4 Ports 1 and 2 Ports 3 and 4 Ports 5 and 6
Flexible There is no traffic segregation based on traffic class
69 © 2013 Cisco and/or its affiliates. All rights reserved.
• If you are not planning on using other VSBs
Topology 3 gives best bandwidth and redundancy for control VLAN
Negative is that is harder to configure
• Flexible allows any configuration
Recommend port-channels
Remember VSM latency is key over bandwidth
• Use VPC or VSS upstream if you have it
70 © 2013 Cisco and/or its affiliates. All rights reserved.
Use the Q&A panel to submit your questions. Experts will start responding those
71 © 2013 Cisco and/or its affiliates. All rights reserved.
• N1K Download and 60-day Eval: www.cisco.com/go/1000vdownload
• N1K Product Page: www.cisco.com/go/1000v
• N1K Community: www.cisco.com/go/1000vcommunity
• N1K Twitter www.twitter.com/official_1000V
• N1K Webinars: www.cisco.com/go/1000vcommunity
• N1K Case Studies: www.tinyurl.com/n1k-casestudy
• N1K Whitepapers www.tinyurl.com/n1k-whitepaper
• N1K Deployment Guide: www.tinyurl.com/N1k-Deploy-Guide
• N1K on UCS Best Practices: www.tinyurl.com/N1k-On-UCS-Deploy-Guide
• VXLAN Web Conference: www.brighttalk.com/webcast/279/41277
72 © 2013 Cisco and/or its affiliates. All rights reserved.
a) Basic L2 switching
b) Security features like ACLs, DHCP snooping, IP Sourceguard, etc..
c) Monitoring features like Netflow, SNMP, SPAN, and ERSPAN
d) Cross platform hypervisor support
e) Advanced features like vpath and integration with ASA1000v, VSG, and Cloud Services Router
f) VXLAN
Which Features of the Nexus 1000v interest you the most?
73 © 2013 Cisco and/or its affiliates. All rights reserved.
Expert responding some of your questions verbally. Use the Q&A panel to continue asking your questions
74 © 2013 Cisco and/or its affiliates. All rights reserved.
A. Coca-Cola Bottling Company is preparing to use the Cisco Nexus 1000V Switch, which resides on the server to deliver VN-Link virtual machine-aware network services.
B. Coca-Cola Bottling Company plans on using The Cisco Nexus 1000V to simplify collaboration within the IT department by clearly separating responsibilities for the server group and network group.
C. Coca-Cola Bottling Company plans on using the Cisco Nexus 1000V Switch to enable vMotion to work properly by giving server specialists the freedom to move hosts around without concerning themselves with quality of service and security settings.
D. A and B only
E. A, B, and C
Cisco Nexus 1000 and Coca-Cola… What do they have in common?
75 © 2013 Cisco and/or its affiliates. All rights reserved.
Those who fill out the Evaluation
Survey will enter a raffle for the
chance to win:
$50 Amazon Gift Card
To complete the evaluation, please click on link
provided in the chat or in the pop-up once the
event is closed.
76 © 2013 Cisco and/or its affiliates. All rights reserved.
If you have additional questions, you can ask them to Louis. He will be answering from June 4 to June 14, 2013 https://supportforums.cisco.com/thread/2220674
You can watch the video or read the Q&A 5 business days after the event at https://supportforums.cisco.com/community/netpro/ask-the-expert/webcasts
77 © 2013 Cisco and/or its affiliates. All rights reserved.
English
Tuesday July 9, at 8:00 a.m. San Francisco (PST) 11:00 a.m. New York (EST) 5:00 p.m. Paris (CEST) 8:30 p.m. Bangalore (IST)
Join Cisco Experts: Amit Singh and Vijay Rao
During the live event, Cisco subject matter experts Amit Singh and Vijay Rao will focus on the simplified "Upgrade Process"& "Focussed Support" from Cisco to Migrate to version 9.1. They would also talk about the changes made to the Licensing model of UCL/CUWL.
Registration opens on June 10 @
https://supportforums.cisco.com/community/netpro/expert-corner#view=webcasts
Topic: Upgrading Cisco Unified Communications Manager
(CUCM) to Version 9.1 (Drive to 9)
78 © 2013 Cisco and/or its affiliates. All rights reserved.
Spanish
Tuesday June 12, at
7:00 a.m. San Francisco (PST)
9:00 a.m. Mexico City (CST)
10:00 a.m. New York (EST)
4:00 p.m. Paris & Madrid (CEST)
Join Cisco Expert: Hector Carranza
During this live event, expert Hector Carranza will give an introduction to Multiprotocol Label Switching (MPLS) and explain how MPLS combines the intelligence of routing protocols with the performance offered by the technologies Layer 2 in order to provide high-capacity services over IP networks. Carranza will also discuss the benefits of MPLS compared to those provided by other technologies used before and will describe scalability and configuration basics necessary to implement MPLS.
Register @
https://supportforums.cisco.com/community/netpro/expert-corner#view=webcasts
Topic: Introduction to Multiprotocol Label Switching
(MPLS): Uses and Benefits
79 © 2013 Cisco and/or its affiliates. All rights reserved.
Portuguese
Tuesday June 18 at
7:00 a.m. San Francisco (PST)
10:00 a.m. New York (EST)
11:00 a.m. Brasilia City
3:00 p.m. Lisbon and London
4:00 p.m. Paris & Madrid (CEST)
Join Cisco Expert: Marcio Teixaira Ferreira
During this live event, you'll learn basic concepts and fundamentals of Border Gateway Protocol (BGP) with Cisco expert Marcio Teixeria Ferreira. He will cover important topics such as when and why to use BGP, common configuration scenarios, and how to troubleshoot common issues.
Register @
https://supportforums.cisco.com/community/netpro/expert-corner#view=webcasts
Topic: Border Gateway Protocol (BGP): Fundamentals,
Configuration, and Troubleshooting
80 © 2013 Cisco and/or its affiliates. All rights reserved.
Russian
Wednesday June 19, at
9:00 a.m. Paris (CEST)
11:00 a.m. Moscow
Join Cisco Expert: Mike Shchekotilov
During this session Cisco subject-matter expert Mike Shchekotilov will talk about certificates and secure integration of Cisco Unified Communications Manager, Cisco TelePresence Video Communication Server, and Cisco TelePresence Content Server. He will then provide a live demo of implementing certificates on the servers using Microsoft Active Directory as certificate authority.
Register @
https://supportforums.cisco.com/community/netpro/expert-corner#view=webcasts
Topic: Secure Communication and Certificates in Cisco
Unified Communications Manager and
Cisco TelePresence
81 © 2013 Cisco and/or its affiliates. All rights reserved.
English Jabber for Windows 9.2 - Configuration and Features
With Cisco expert Maqsood Mushtaq
Learn and ask questions about how to install, configure, and troubleshoot Cisco
Jabber for Windows 9.2
Ends June 14, 2013
Cisco Unified Wireless and Cisco Unified Access
With Cisco experts Richard Hamby, Patrick Croak, and Nicholas Tate
Learn and ask questions about the Cisco Wireless portfolio of controllers, access
points, and latest WLAN features.
Ends June 14, 2013
Topic: Wireless LAN Controllers
With Cisco expert Nicolas Darchis
Learn and ask questions about how to configure and troubleshoot Cisco Wireless
LAN Controllers (WLC)
Starts June 17, 2013
Topic: How to Configure and Troubleshoot Open Shortest Path First (OSPF)
With Cisco expert Vignesh Rajendran
Learn and ask questions about how to configure and troubleshoot OSPF
Starts June 17, 2013
Topic: Installing & Configuring Cisco Prime Collaboration 9.0
With Cisco experts Aashish Jolly and Abhijit Singh Anand
Learn about install best practices for Cisco Prime Collaboration 9.0 covering the
different deployment models available.
Starts June 18, 2013
Join the discussion for these Ask The Expert Events at:
https://supportforums.cisco.com/community/netpro/expert-corner#view=ask-the-experts
82 © 2013 Cisco and/or its affiliates. All rights reserved.
• Cisco Live offers unparalleled opportunities to increase your knowledge of Cisco products and solutions. Educational content is spread across four programs:
Technical Education
IT Management
Developer Network Program
Service Provider
• The week also includes a full slate of Innovation Sessions, Keynotes, Super Sessions, and multiple opportunities to meet one-on-one with Cisco experts.
• We will be in the World of Solutions in Services area located in front of Data Center.
• More information: https://supportforums.cisco.com/community/netpro/idea-center/cisco-live-orlando-2013
© 2013 Cisco and/or its affiliates. All rights reserved. 83
If you speak Spanish, Portuguese, Japanese, Polish or Russian,
we invite you to ask your questions and collaborate in your
language:
• Spanish https://supportforums.cisco.com/community/spanish
• Portuguese https://supportforums.cisco.com/community/portuguese
• Japanese https://supportforums.cisco.com/community/csc-japan
• Polish https://supportforums.cisco.com/community/etc/netpro-polska
• Russian https://supportforums.cisco.com/community/russian
© 2013 Cisco and/or its affiliates. All rights reserved. 84
https://supportforms.cisco.com
http://bit.ly/facebookcsc
http://bit.ly/twittercsc
http://bit.ly/youtubecsc
http://bit.ly/googlecsc
http://bit.ly/linkedincsc
Newsletter Subscription: http://bit.ly/newscsc
http://bit.ly/itunescsc
http://bit.ly/androidcsc
85 © 2013 Cisco and/or its affiliates. All rights reserved.
A. Coca-Cola Bottling Company is preparing to use the Cisco Nexus 1000V Switch, which resides on the server to deliver VN-Link virtual machine-aware network services.
B. Coca-Cola Bottling Company plans on using The Cisco Nexus 1000V to simplify collaboration within the IT department by clearly separating responsibilities for the server group and network group.
C. Coca-Cola Bottling Company plans on using the Cisco Nexus 1000V Switch to enable vMotion to work properly by giving server specialists the freedom to move hosts around without concerning themselves with quality of service and security settings.
D. A and B only
E. A, B, and C