Condition Remedial Measures Selection
Small Diameter
30% Design Package 2
Central Basin – Geographical Location
July 2018
Prepared for:
Central Basin
Condition Remedial Measures Selection
Small Diameter
30% Design Package 2
Central Basin – Geographical Location
July 2018
Basin Planning Consultant for the Sanitary Sewer Overflow Reduction Program (SSORP) Team
Prepared for:
Prepared by: FREESE AND NICHOLS, INC.
Texas Professional Engineering Firm No. F-2144 9601 McAllister Freeway, Suite 1008
San Antonio, Texas 78216 210-298-3800
CP&Y, INC. Texas Professional Engineering Firm No. F-1741
12500 San Pedro, Ste. 450 San Antonio, Texas 78216
210-494-8004
7/13/2018
07/13/18
7/13/2018
i
TABLE OF CONTENTS
1.0 INTRODUCTION ......................................................................................................................................... 1
2.0 REMEDIAL MEASURES ........................................................................................................................... 1
3.0 ADDITIONAL AND BASE PIPES ........................................................................................................... 3
4.0 ASSUMPTIONS ............................................................................................................................................ 3
4.1 Laterals ...................................................................................................................................................... 3
4.2 Pavement Repair ................................................................................................................................... 4
4.3 Point Repairs ........................................................................................................................................... 5
4.4 Manholes .................................................................................................................................................. 6
5.0 QUANTITIES ................................................................................................................................................ 6
5.1 Assets ......................................................................................................................................................... 6
5.2 Pavement Repair ................................................................................................................................... 7
5.3 Bypass Pumping .................................................................................................................................... 7
6.0 SITE IMPACT CHECK................................................................................................................................ 8
7.0 DESIGN PLAN SHEETS ............................................................................................................................ 8
8.0 CONCLUSION .............................................................................................................................................. 9
APPENDICES
APPENDIX A – PACKAGE MAPS
1
1.0 INTRODUCTION
The purpose of the Basin Planning Consultants (BPC) is to provide support to the Sanitary Sewer
Overflow Reduction Program (SSORP) team. This was mandated by the 2013 Consent Decree (CD)
between San Antonio Water System (SAWS) and the Environmental Protection Agency (EPA).
Freese and Nichols, Inc. (FNI) and CP&Y developed 30% design packages for the small diameter
D and E assets within the Central Basin chosen by the SSORP team to be rehabilitated. Small
diameter pipes are less than 24”; between 6” and 21”.
This Package 2 TM contains the 30% design information for the second set of assets selected by
the SSORP team. Package 2 was the second highest priority package, and contains Category E
assets that coincide with City of San Antonio street improvement projects. All packages being
submitted are summarized in Table 1-1. This TM documents the constructability issues, desktop
studies, and recommended condition remedial measures (CRM) for each pipe. The CRMs were
assigned in the 10% design analysis; see Condition Remedial Measures Selection Small Diameter
Technical Memorandum submitted January 2018. Also included in this TM are design plan maps
for each asset which are located within Appendix A.
Table 1-1 – Package Summary
Package Number
Number of Assets
Length of Pipe (LF)
Package Description
1 30 9,064 E Pipes - located under roads
2 12 3,815 D and E Pipes that align with
City of San Antonio bond projects
3 101 27,459 Similar Geographic Location
4 135 36,702 Similar Geographic Location
5 131 37,184 Similar Geographic Location
6 105 29,310 Similar Geographic Location
2.0 REMEDIAL MEASURES
FNI used the decision guidelines developed by SAWS in the Guidelines TM to develop a protocol
with which to recommend a remedial measure. This protocol is shown in Figure 2-1 as a flowchart
(decision tree) resulting in a preferred remedial measure.
NO
Guideline #8
Avg. no. of
mainline point
repairs for CIPP
> 1/100 foot or
25% of length?
YES
NO
Guideline #9
Guideline #4
Exist. CIPP pipe
require MH to MH
remediation?
YES
NO
Guideline #3
Is pipe ≤ 6”and in
need of MH to MH
remediation?
YES
NO DONE – open-cut,
CIPP, pipeburst
Guideline #5
< 75% of pipe
inspected?
YES
NO Is pipe ≥ 24”
in diameter?
NO
Guideline #7
TOP ≤ 3’ or
invert ≥ 20’?
Guideline #6
YES
DONE – Open-cut or
pipeburst
DONE – Open-cut
DONE – Open-cut
YES
DONE – open-cut,
CIPP, slipline
YES
NO
NO
YES
DONE – open-cut, CIPP
TOP ≤ 3’ or
invert ≥ 20’?
NO
DONE – Open-cut
YES
Is condition
rating “D” and
PCI ≥ 86?
Is asset
adjacent to an
“E” pipe?
DONE – Recommend monitoring
Note as an “Opportunity D” and include with
adjacent “E” pipe 30% package
Is condition
rating an “E”?
NO
YES
NO
YES
YES
NO
Guideline #1
Is the avg.
number of point
repairs for
pipeburst > 1/100
foot?
Is pipe ≥ 24”
in diameter?
Figure 2.1 - Remedial Measure Flow Chart
3
3.0 ADDITIONAL AND BASE PIPES
The SSORP team separated assets into two groups, Base pipes and Additional pipes. Base pipes
are the condition pipes that will be repaired by 2023, per the CD. Additional pipes are assets in
the same geographic location as the Base pipe and, if funds allow, will be included in the
construction packages for rehabilitation. Base and Additional pipes are quantified separately in
the quantity tables. In the plan sheets (C Sheets), Additional pipes have an orange halo.
Moreover, the asset data sheets (F Sheets) identify the assets as either Additional or Base.
4.0 ASSUMPTIONS
The following assumptions were applied to maintain a consistent design throughout the 30%
design packages.
4.1 LATERALS
A lateral shapefile was created by the BPCs using the defect codes in the PACP database provided
by SAWS. This shapefile was used to populate the quantity tables for the number of laterals on
each pipe. The defect codes used to identify laterals in the pipe are shown in Table 4-1. The
location and status of the laterals will need to be determined by the surveyor and final design
engineer.
Table 4-1 - Lateral Defect Codes
Defect Code Definition
TB Tap Break-in/Hammer
TBA Tap Break-in/Hammer Activity
TBD Tap Break-in/Hammer Defective
TBI Tap Break-in/Hammer Intruding
TF Tap Factory
TFA Tap Factory Activity
TFD Tap Factory Defective
TFI Tap Factory Intruding
TS Tap Saddle
TSA Tap Saddle Activity
TSD Tap Saddle Defective
TSI Tap Saddle Intruding
4
4.2 PAVEMENT REPAIR
The City of San Antonio (CoSA) determines the street repair necessary for disturbed pavement
based on the pavement condition index (PCI) of the road. Roads with a PCI greater than or equal
to 86 are considered to be in excellent condition and require curb-to-curb restoration (full street
restoration). Roads with a PCI less than 50 are considered to be in poor condition and only require
repair of the road within the limits of the trench. Roads with a PCI between 50 and 85 are
considered to be in fair condition and are evaluated by CoSA on a case-by-case basis.
The estimated quantity of pavement repair for the following CRMs is listed below. For all streets,
regardless of the PCI rating; CIPP was assumed to have no pavement repair. For pipes with a CRM
of POINT REPAIR, a 20’ length by 10’ width was assumed. For pipes with a CRM of BORE, it was
assumed that the bore pit would be 40’x10’ and the receiving pit would be 10‘x10’.
• PCI greater than or equal to 86
o OPEN-CUT - will require full pavement repair for the full length of pipe, curb to
curb.
o PIPEBURST - will require full pavement repair for the full length of pipe, curb to
curb.
• PCI between 50 and 85
o OPEN-CUT & PIPEBURST - will require pavement repair for the full length of pipe,
10’ wide.
• PCI of less than 50
o OPEN-CUT - will require pavement repair for the length of pipe and width of the
trench. Trench width is typically the diameter of the pipe plus 3’.
o PIPEBURST - will require pavement repair for 10% of the length of the asset and
the width of the trench. Trench width is typically the diameter of the pipe plus 3’.
5
4.3 POINT REPAIRS
Point repairs were identified two ways; one was to create a shapefile of specific defects (i.e. BVV,
HVV, XP, etc) and show them geospatially on a map. The second way was to identify defects in
need of a point repair through CCTV review. The point repairs identified through CCTV review
only exist for pipes reviewed after the 4/17/2017 OPEN-CUT meeting conducted by SAWS. During
this meeting, SAWS requested that the point repairs be identified by a professional after the CCTV
review had begun. The BPCs did not identify point repairs using CCTV for any assets prior to this
meeting. The point repairs shown on the map (C Sheets) are from the shapefile, while the number
of point repairs identified through CCTV review are shown on the data sheets (F Sheets) in the
package maps. The point repairs shown on the maps (C Sheets) may not match the number of
point repairs identified by reviewers on the F sheets. Only point repairs identified through CCTV
review were used for cost estimating. The final design engineer will need to verify the number
and location of all point repairs. Table 4-2 shows the defect codes selected to be shown on the
map.
Table 4-2 - Defects Shown on Package Maps
PACP Definition Code Defect
'BSV' Broken Soil Visible
'BVV' Broken Void Visible
'FH4' Hinge Fracture (4 Fractures)
'FH3' Hinge Fracture (3 Fractures)
'H' Hole
'HSV' Hole Soil Visible
'HVV' Hole Voids Visible
'IG' Infiltration Gusher
'JAL' Joint Align Large
'JOL' Joint Offset Large
'JSL' Joint Separation Large
'RBJ' Roots Ball Joint
'RBL' Roots Ball Lateral
'RBB' Roots Ball Barrel
'RBC' Roots Ball Connection
'XP' Collapse
6
4.4 MANHOLES
The quantity of manholes to be rehabilitated were identified by the type of CRM recommended
for each asset. The CRM and the associated assumed manhole rehab is listed below.
• CIPP – rehabilitate all manholes
• SLIPLINING – rehabilitate all manholes
• PIPEBURST – rehabilitate all manholes
• OPEN-CUT – install new manhole
• BORE – install new manhole
5.0 QUANTITIES
5.1 ASSETS
The quantities for the remedial measures for Package 2, separated for Base and Additional pipe,
are shown in Table 5-1.
Table 5-1 - Summary of Package 2 Assets
PREFERRED REMEDIAL MEASURE Diameter (in) Base (LF) Additional (LF) Total Length (LF)
CIPP & POINT REPAIR 8 370 0 370
CIPP & POINT REPAIR Total 370 0 370
PIPEBURST 8 493 759 1,252
PIPEBURST Total 493 759 1,252
PIPEBURST & POINT REPAIR 8 0 393 393
PIPEBURST & POINT REPAIR Total 0 393 393
REPLACE OPEN-CUT
8 362 0 362
10 654 0 654
12 384 0 384
15 399 0 399
REPLACE OPEN-CUT Total 1800 0 1,800
TOTAL 3,815
7
5.2 PAVEMENT REPAIR
The street repairs are summarized in Table 5-2.
Table 5-2 - Pavement Repair for Remediation Measures
Item No. Item Description Unit Quantity
203 Tack Coat GAL 509
205.2 Hot Mix Asphaltic Pavement - Type B (10" Compacted Depth) SY 1,218
205.4 Hot Mix Asphaltic Pavement - Type D (2" Compacted Depth) SY 5,093
206 Asphalt Treated Base - Milling (0" to 2") SY 5,093
5.3 BYPASS PUMPING
Bypass pumping data was provided in order to get a high-level cost estimate for the 30%
condition design package. Flows in the pipe, number of set ups, upstream (US) suction manhole
and downstream (DS) discharge manhole, and the length of the bypass were provided and
quantified separately for Base and Additional pipes. For this package there was a total of 6 by-
pass pumping set ups for Base pipes and 2 for Additional pipes.
A bypass set up was determined to be a configuration that removes sewage from the pipe that is
being rehabbed. Bypass will be designed based on number of pipes adjacent to each other unless
there is an Additional pipe that breaks the linked pipe. Bypass for “Additional” pipes are
quantified separately.
In order to determine the cost of the bypass pumping set ups, peak wet weather and average
day flows (MGD) were provided for each pipe on the F Sheets. For pipes 12" and greater, the
flows shown were taken from the FNI model that was run with 30% I/I reduction. Pipes 6" - 10"
show peak flows calculated using Manning's Equation assuming full flow in the pipe.
Bypass pumping length was determined by identifying the upstream suction manhole and
measuring the length to the downstream discharge manhole. If multiple sewer mains were
connected to the pipe, then an upstream and downstream manhole was selected in order to
provide a bypass length for cost estimation. These upstream suction manholes and downstream
8
discharge manholes may not be preferred by the final design engineer and therefore may be
modified during final design.
6.0 SITE IMPACT CHECK
Desktop studies to obtain environmental and geotechnical data for each asset were performed.
The results of these studies are located in the F Sheets. Along with the desktop studies, a
windshield survey was conducted for all assets. Images shown on the F Sheets were taken during
these site visits, with Google Earth images were used in areas requiring additional safety (i.e. a
busy street) or no access (private property).
7.0 DESIGN PLAN SHEETS
In addition to the desktop studies/survey information; Package 2 design plan sheets include the
following information for each asset:
• Pipe COMPKEY
• Package priority number
• UNITID (upstream MH)
• UNITID 2 (downstream MH)
• Number of Laterals (taken from PACP codes provided by SAWS)
• Number of Point Repairs (taken from PACP codes provided by SAWS)
• Pipe Material (identified in 10% Design)
• Pipe Length
• Surveyed Pipe Length (identified in 10% Design)
• Diameter (nominal diameter of pipe in inches)
• Verified Condition (SAWS-provided rating; and indication if consultant disagreed)
• 100-year floodplain
• Sags
• Preferred remedial measure
• Low-Income area
9
• Street width (if asset is located in a street)
• PCI Rating of street on which asset is located
• Bypass Pumping Data
o Wet weather flow
▪ Obtained from the model for pipes 12” and greater
▪ Calculated using Manning’s Equation for pipes less than 12” in diameter
o Average Day flow
▪ Obtained from the model for pipes 12” and greater
▪ No data provided for pipes less than 12” in diameter
• Parcels Impacted
• Quantities
o Pavement to be replaced (full street for linear foot [LF] repair, half street for LF
repair, and width of trench for LF repair)
o Linear footage of pipe to be repaired
8.0 CONCLUSION
Package 2 contains pipes considered the second highest priority by SAWS; pipes that align with
CoSA bond projects. The package contains 12 assets totaling 3,815 LF (0.72 miles) of Base and
Additional pipe to be rehabilitated.
10
APPENDIX A
Package Maps
§̈¦
§̈¦
§̈¦
§̈¦
§̈¦
§̈¦
§̈¦
§̈¦
§̈¦
§̈¦
§̈¦
City of Lackland AFB
City of Leon Valley
City of Kirby
City of China Grove
City of Terrell Hills
City of Alamo Heights
City of Windcrest
City of Olmos Park
City of Castle Hills
City of Balcones Heights
SAN ANTONIO WATER SYSTEMCENTRAL BASIN CONDITION DESIGN DEVELOPMENT (30%) - PACKAGE 2
I
SSO REDUCTION PROGRAMJob No.: SWB16406
JULY 2018
LOCATION MAP
Engineer:
Freese and Nichols, Inc.Texas Firm: F-21449601 McAllister Freeway, Ste. 1008San Antonio, TX 782016 (210) 298-3898
SURVEYORGonzalez-De La Garza4800 Fredericksburg RoadSuite 200 San Antonio, TX 78229Texas Firm: F-10015
CP&Y, Inc.12500 San Pedro AveSuite 450San Antonio, TX 78216Texas Firm: F-1741
CP&Y, Inc.12500 San Pedro AveSuite 450San Antonio, TX 78216Texas Firm: F-1741
GEOTECHNICALENGINEERArias Geoprofessionals142 Chula Vista DrSan Antonio, TX 78232Texas Firm: F-32
Crea
ted By
Free
se an
d Nich
ols, In
c.Jo
b No.:
SWB
1640
6Lo
catio
n: P:\
gis\FA
NI16
0013
8\30%
Con
dition
Sma
ll Diam
eter P
kgs\C
PY_P
acka
ge2\0
0_Co
ver_S
heet.
mxd
Upda
ted: W
edne
sday
, July
11, 2
018 9
:15:31
AM
CIVIL ENGINEER
ENVIRONMENTALCONSULTANT
410
410
10
10
10
10
35
35
37
3537
NOT FOR CONSTRUCTION
THIS DOCUMENT IS RELEASED FOR THEPURPOSE OF INTERIM REVIEW UNDER THEAUTHORITY OF: TADEUSZ J. STAWASZ TEXAS NO:102666 ON DATE: 7/13/18IT IS NOT TO BE USED FOR CONSTRUCTION,BIDDING OR PERMINT PURPOSE.
Crea
ted By
Free
se an
d Nich
ols, In
c.Jo
b No.:
SW
B164
06Lo
catio
n: P:\
gis\FA
NI16
0013
8\30%
Con
dition
Small
Diam
eter P
kgs\C
PY_P
acka
ge2\0
1_Ke
y_Ma
p_Up
dated
.mxd
Upda
ted: T
hursd
ay, M
arch 2
2, 20
18 11
:28:08
AM
LEGENDInterstates100Yr FloodplainsCivil Sheet NumberCity LimitOther City
I0 5,000
SCALE IN FEET
THIS DOCUMENT IS INCOMPLETE AND ISRELEASED TEMPORARILY FOR INTERIMREVIEW ONLY. IT IS NOT INTENDED FORCONSTRUCTION, BIDDING, OR PERMIT PURPOSES.____________________________, P.E.SERIAL NO.:________________DATE: _____________________No. Revision By Date
KEY MAP
Date: 4/11/2018DESIGN:DRAWN:
CHECKED:G-1
§̈¦
§̈¦
§̈¦
§̈¦ §̈¦
§̈¦
§̈¦
§̈¦
§̈¦
§̈¦
§̈¦
§̈¦
City of Castle Hills
City of Terrell Hills
City of Alamo Heights
City of Olmos Park
City of Leon Valley
City of Lackland AFB
City of Balcones Heights
City of Kirby
City of Windcrest
54
3
1
6
8
7
2
410
410
10
10
10
37
37
35
35
35
410
10
TADEUSZ J. STAWSZ 102666 7/13/18
NOT FOR CONSTRUCTION
THIS DOCUMENT IS RELEASED FOR THEPURPOSE OF INTERIM REVIEW UNDER THEAUTHORITY OF: TADEUSZ J. STAWASZ TEXAS NO:102666 ON DATE: 7/13/18IT IS NOT TO BE USED FOR CONSTRUCTION,BIDDING OR PERMINT PURPOSE.
Crea
ted By
Free
se an
d Nich
ols, In
c.Jo
b No.:
SW
B164
06Lo
catio
n: P:\
gis\FA
NI16
0013
8\30%
Con
dition
Small
Diam
eter P
kgs\C
PY_P
acka
ge2\0
2_Sh
eet_I
ndex
.mxd
Upda
ted: T
hursd
ay, M
arch 2
2, 20
18 11
:30:01
AMSHEET INDEX==========================================================================================================================================================================
THIS DOCUMENT IS INCOMPLETE AND ISRELEASED TEMPORARILY FOR INTERIMREVIEW ONLY. IT IS NOT INTENDED FORCONSTRUCTION, BIDDING, OR PERMIT PURPOSES.____________________________, P.E.SERIAL NO.:________________DATE: _____________________No. Revision By Date
SHEET INDEX
Date: 4/11/2018DESIGN:DRAWN:
CHECKED:G-2
TADEUSZ J. STAWSZ 102666 7/13/18
NOT FOR CONSTRUCTION
THIS DOCUMENT IS RELEASED FOR THEPURPOSE OF INTERIM REVIEW UNDER THEAUTHORITY OF: TADEUSZ J. STAWASZ TEXAS NO:102666 ON DATE: 7/13/18IT IS NOT TO BE USED FOR CONSTRUCTION,BIDDING OR PERMINT PURPOSE.
Crea
ted By
Free
se an
d Nich
ols, In
c.Jo
b No.:
SWB
1640
6Lo
catio
n: P:\
gis\FA
NI16
0013
8\30%
Con
dition
Sma
ll Diam
eter P
kgs\C
PY_P
acka
ge2\0
4_Qu
antity
_Tab
les_P
age.m
xdUp
dated
: Tue
sday
, May
01, 2
018 1
2:07:5
9 PM
THIS DOCUMENT IS INCOMPLETE AND ISRELEASED TEMPORARILY FOR INTERIMREVIEW ONLY. IT IS NOT INTENDED FORCONSTRUCTION, BIDDING, OR PERMIT PURPOSES.__________________________, P.E.SERIAL NO. ________________DATE: _____________________No. Revision By Date
QUANTITY TABLES PAGE
Date: 5/1/2018DESIGN:DRAWN:
CHECKED:Q-1
TADEUSZ J. STAWSZ 102666 7/13/18
NOT FOR CONSTRUCTION
THIS DOCUMENT IS RELEASED FOR THEPURPOSE OF INTERIM REVIEW UNDER THEAUTHORITY OF: TADEUSZ J. STAWASZ TEXAS NO:102666 ON DATE: 7/13/18IT IS NOT TO BE USED FOR CONSTRUCTION,BIDDING OR PERMINT PURPOSE.
Depth: 5.7Rim: 843.55UnitID: 3446
Depth: 5Rim: 845.57UnitID: 4039
Depth: 7.3Rim: 857.5
UnitID: 3974
Depth: 4.98Rim: 848.25UnitID: 5363
10", 370 LF
Compkey: 967874
8", 37
0 LF
Compke
y: 9700
68
TAMWORTH DR (44)
MT KISCO (25)
HOMERIC (77)
HOMERIC (80)
HOMERIC (78)
HOMERIC (84)
TAMWORTH DR (57)
BRIARCLIFF DR (60)
BRIARCLIFF D
R (59)
LOCKHILL-SELMA RD (78)
LOCKHILL-SELMA RD (83)
MT KISCO (45)
10"
15"
12"10"
10"
10"
10"
10"
10"
15"
8"
8"
8"
8"
8"
8"
8"
8"
8"
8"
8"
8"
8"
8"
8"
8"
8"
8"
8"
8"
Depth: 7.97Rim: 858
UnitID: 4189
Depth: 6Rim: 848.38
UnitID: 16787
Depth: 6.5Rim: 863.5
UnitID: 5565
Depth: 6.9Rim: 852.5
UnitID: 4188
Depth: 5.5Rim: 850.07UnitID: 5365
Depth: 7.24Rim: 852.5
UnitID: 4038
Depth: 5.41Rim: 844.1
UnitID: 3447
Depth: 6.3Rim: 858.27UnitID: 4190
Depth: 4.16Rim: 849.7
UnitID: 5564
Depth: 3.66Rim: 854.7
UnitID: 5362
Depth: 4.81Rim: 848.74UnitID: 5563
Depth: 5.38Rim: 858.5
UnitID: 16783
Depth: 16.06Rim: 856.75UnitID: 3449
Depth: 3.84Rim: 855.45
UnitID: 16784
Source: Esri, DigitalGlobe, GeoEye, Earthstar Geographics, CNES/Airbus DS, USDA, USGS, AeroGRID, IGN, and the GISUser Community
Date:
Crea
ted By
Free
se an
d Nich
ols, In
c.Jo
b No.:
SWB
1640
6Lo
catio
n: P:\
gis\FA
NI16
0013
8\30%
Con
dition
Sma
ll Diam
eter P
kgs\C
PY_P
acka
ge2\0
5_Ma
p_Bo
ok.m
xdUp
dated
: Mon
day,
July
02, 2
018 9
:04:48
AM
LEGEND!( Manhole
CIPPCIPP & POINT REPAIRBOREPIPEBURSTPIPEBURST & POINT REPAIRREPLACE OPEN-CUTCPS Electric OH PrimaryCPS Gas Distribution MainAdditional Line
! Potential Point Repair Location
8" and SmallerWastewater Line10" and LargerWastewater LineWater MainLateralsRoadStream10-ft ContourParcel100Yr Floodplains
Project
I0 100 200
SCALE IN FEET
Title: Compkey: 967874 & 970068
SSO Basin Planning Consultant30% Condition Small Diameter
7/11/2018
1
Sheet C-1NOT FOR
CONSTRUCTIONThis document is release fo the purpose of interim review under the authority of: Tadeus J. StawaszTexas No. 102666 on Date: 7/13/18.It is not to be used for construction, bidding, or permint purpose.
ASSET INFORMATION SHEET F-1a
Diameter 10
Length 370.00
Length Surveyed 318.00
75% Televised
No of Laterals 0
Material CP
VerifiedCondition E
Condition (Consultant)Siphon #
Sag yes No of Point Repairs 0
CompKey 967874
Final Rehab REPLACE OPEN-CUT
Basin CENTRAL
Upstream MH 5363
Downstream MH 4039
US Depth 4.98
DS Depth 5
YesConstruction Access Homeric
YesOperational Access Homeric
Jurisdictional Water None likely.No
NoEndangered Species None likely.
Karst Zones Within karst zone 3. Karst survey required.Yes
NoCritical Habitat No wetlands mapped.
NoEnvironmental factors Within transition zone. No action required.
YesHazardous Sites Brake Check is southeast of the segment and lists two LPST site with significant groundwater contamination. Chico Family Holdings lists IHWCA site and is southeast of the segment. Recommend field investigation for any unreported sites and/or dumps.
NoArcheolgical Sites No known cultural resources conflict. Coordination with CoSA OHP needed. If work will exceed five acres or 5,000 cubic yards of earth moving, consultation with THC needed.
Geomorphology Issues Potential Ground Water Not AnticipatedNo
Geotechnical issues Geology: Pecan Gap, Rock Excavation Equipment May Not be Required, Potential Sloughing and Caving Not Anticipated
No
Exist Utilities Crosses 2" gas line at MH #5363, crosses 2" gas line at MH #4039, OHEYes
YesPermit Conditions CoSA ROW Permit (Homeric)
Available Grade
Available Cover
Large Trees
Site Access by Combo Truck
Crosses Creek, TxDOT Rd, or Bridge
Large WTR Mains
Large Gas Mains
Easement Required (number of parcels)
0
Point Repair Identified by a Professionalyes
By-Pass Info
Peak Wet Weather (MGD) 0.10- From Model for Pipes > 12"- Calculated for Pipes < 12" with Mannings Assuming Full Flow
US Suction Manhole 5563
DS Discharge Manhole 3446
By-Pass Length 920
By-Pass Pumping Information
Street Width 36
Quantity of Street Repair (LF) 370.00
Street Repair Data
30% Package Number 2
Reason Selected for 30% Concrete E
Reviewed in 10% Design Yes
Base or Additional Pipe Base Pipe
On CPMS Project No
Avg Day (MGD)- From Model for Pipes > 12"
NOT FOR CONSTRUCTION
THIS DOCUMENT IS RELEASED FOR THEPURPOSE OF INTERIM REVIEW UNDER THEAUTHORITY OF: TADEUSZ J. STAWASZ TEXAS NO:102666 ON DATE: 7/13/18IT IS NOT TO BE USED FOR CONSTRUCTION,BIDDING OR PERMINT PURPOSE.
ASSET INFORMATION SHEET F-1b
Diameter 8
Length 370.00
Length Surveyed 372.00
75% Televised
No of Laterals 9
Material CP
VerifiedCondition E
Condition (Consultant)Siphon #
Sag No No of Point Repairs 4
CompKey 970068
Final Rehab CIPP & POINT REPAIR
Basin CENTRAL
Upstream MH 3974
Downstream MH 4039
US Depth 7.3
DS Depth 5
YesConstruction Access Located in alley behind Tamworth Dr, unpaved, utility poles. MH 4039 is located in the ROW of Homeric. MH 3974 is located in the alley.
YesOperational Access
Jurisdictional Water No
NAEndangered Species
Karst Zones NA
NACritical Habitat
NAEnvironmental factors
NAHazardous Sites
NAArcheolgical Sites
Geomorphology Issues NA
Geotechnical issues NA
Exist Utilities Parallel 2" gas main, utility poles, underground distribution, telephone, and underground cables.
Yes
YesPermit Conditions COSA for Homeric
Available Grade
Available Cover
Large Trees
Site Access by Combo Truck
Crosses Creek, TxDOT Rd, or Bridge
Large WTR Mains
Large Gas Mains
Easement Required (number of parcels)
0
Point Repair Identified by a Professionalyes
By-Pass Info
Refer to F Sheet for COMPKEY 967874
Peak Wet Weather (MGD) 0.62- From Model for Pipes > 12"- Calculated for Pipes < 12" with Mannings Assuming Full Flow
US Suction Manhole *
DS Discharge Manhole *
By-Pass Length
By-Pass Pumping Information
Street Width 36
Quantity of Street Repair (LF) 80.00
Street Repair Data
30% Package Number 2
Reason Selected for 30% Concrete E
Reviewed in 10% Design Yes
Base or Additional Pipe Base Pipe
On CPMS Project No
Avg Day (MGD)- From Model for Pipes > 12"
NOT FOR CONSTRUCTION
THIS DOCUMENT IS RELEASED FOR THEPURPOSE OF INTERIM REVIEW UNDER THEAUTHORITY OF: TADEUSZ J. STAWASZ TEXAS NO:102666 ON DATE: 7/13/18IT IS NOT TO BE USED FOR CONSTRUCTION,BIDDING OR PERMINT PURPOSE.
MH 7722 locatedfurther downstream.
MH 24496 locatedfurther upstream.
Depth: 7.31Rim: 828
UnitID: 80686
Depth: 6.13Rim: 808
UnitID: 24119
Depth: 6.3Rim: 819.94
UnitID: 807928"
, 270
LFCo
mpke
y: 10
4035
5BR
OADW
AY (7
5)W TERRA ALTA (44) E TERRA ALTA (78)
BROA
DWAY
(78)
MERRIFORD (52)
8"
6"
6"
8"8"
6"
8"
8"
8"8"
8"
8"8"
Depth: 6Rim: 816.5
UnitID: 80646
Depth: 9.2Rim: 801.3
UnitID: 80647Depth: 9.4Rim: 813.5
UnitID: 90654
Depth: 5.25Rim: 827.3
UnitID: 80829
Depth: 13.1Rim: 830.5
UnitID: 90662
LINDENMUTH REAL ESTATE3.75 Acres
WINDSOR COURT CONDOMINIUM3.21 Acres
CHERBOURGH SQUARE3.17 Acres
8", 8
0 LF
Comp
key:
1040
356
Source: Esri, DigitalGlobe, GeoEye, Earthstar Geographics, CNES/Airbus DS, USDA, USGS, AeroGRID, IGN, and the GISUser Community
Date:
Crea
ted By
Free
se an
d Nich
ols, In
c.Jo
b No.:
SWB
1640
6Lo
catio
n: P:\
gis\FA
NI16
0013
8\30%
Con
dition
Sma
ll Diam
eter P
kgs\C
PY_P
acka
ge2\0
5_Ma
p_Bo
ok.m
xdUp
dated
: Mon
day,
July
02, 2
018 9
:05:27
AM
LEGEND!( Manhole
CIPPCIPP & POINT REPAIRBOREPIPEBURSTPIPEBURST & POINT REPAIRREPLACE OPEN-CUTCPS Electric OH PrimaryCPS Gas Distribution MainAdditional Line
! Potential Point Repair Location
8" and SmallerWastewater Line10" and LargerWastewater LineWater MainLateralsRoadStream10-ft ContourParcel100Yr Floodplains
Project
I0 100 200
SCALE IN FEET
Title: Compkey: 1040355 & 1040356
SSO Basin Planning Consultant30% Condition Small Diameter
7/11/2018
2
Sheet C-2NOT FOR
CONSTRUCTIONThis document is release fo the purpose of interim review under the authority of: Tadeus J. StawaszTexas No. 102666 on Date: 7/13/18.It is not to be used for construction, bidding, or permint purpose.
ASSET INFORMATION SHEET F-2a
Diameter 8
Length 270.00
Length Surveyed 260.40
75% Televised
No of Laterals 6
Material CT
VerifiedCondition E
Condition (Consultant)Siphon #
Sag Yes No of Point Repairs 0
CompKey 1040355
Final Rehab PIPEBURST
Basin CENTRAL
Upstream MH 80792
Downstream MH 24119
US Depth 6.3
DS Depth 6.13
YesConstruction Access Located in ROW of Broadway
YesOperational Access Located in ROW of Broadway
Jurisdictional Water No
NAEndangered Species
Karst Zones NA
NACritical Habitat
NAEnvironmental factors
NAHazardous Sites
NAArcheolgical Sites
Geomorphology Issues NA
Geotechnical issues NA
Exist Utilities Parallel 4" gas main and 8" water mainYes
YesPermit Conditions COSA for Broadway
Available Grade
Available Cover
Large Trees
Site Access by Combo Truck
Crosses Creek, TxDOT Rd, or Bridge
Large WTR Mains
Large Gas Mains
Easement Required (number of parcels)
0
Point Repair Identified by a ProfessionalNo
By-Pass Info
Peak Wet Weather (MGD) 0.69- From Model for Pipes > 12"- Calculated for Pipes < 12" with Mannings Assuming Full Flow
US Suction Manhole 24496
DS Discharge Manhole 7722
By-Pass Length 1125
By-Pass Pumping Information
Street Width 28
Quantity of Street Repair (LF) 270.00
Street Repair Data
30% Package Number 2
Reason Selected for 30% Other E
Reviewed in 10% Design Yes
Base or Additional Pipe Additional Pipe
On CPMS Project No
Avg Day (MGD)- From Model for Pipes > 12"
NOT FOR CONSTRUCTION
THIS DOCUMENT IS RELEASED FOR THEPURPOSE OF INTERIM REVIEW UNDER THEAUTHORITY OF: TADEUSZ J. STAWASZ TEXAS NO:102666 ON DATE: 7/13/18IT IS NOT TO BE USED FOR CONSTRUCTION,BIDDING OR PERMINT PURPOSE.
ASSET INFORMATION SHEET F-2b
Diameter 8
Length 80.00
Length Surveyed 86.50
75% Televised
No of Laterals 1
Material VCP
VerifiedCondition E
Condition (Consultant)Siphon #
Sag Yes No of Point Repairs 0
CompKey 1040356
Final Rehab PIPEBURST
Basin CENTRAL
Upstream MH 80686
Downstream MH 80792
US Depth 7.3
DS Depth 6.3
YesConstruction Access Located in ROW of Broadway
YesOperational Access
Jurisdictional Water No
NAEndangered Species
Karst Zones NA
NACritical Habitat
NAEnvironmental factors
NAHazardous Sites
NAArcheolgical Sites
Geomorphology Issues NA
Geotechnical issues NA
Exist Utilities Parallel 3" gas main and 8" water mainYes
YesPermit Conditions COSA for Broadway
Available Grade
Available Cover
Large Trees
Site Access by Combo Truck
Crosses Creek, TxDOT Rd, or Bridge
Large WTR Mains
Large Gas Mains
Easement Required (number of parcels)
0
Point Repair Identified by a ProfessionalNo
By-Pass Info
Refer to F Sheet for COMPKEY 1040355
Peak Wet Weather (MGD) 1.72- From Model for Pipes > 12"- Calculated for Pipes < 12" with Mannings Assuming Full Flow
US Suction Manhole *
DS Discharge Manhole *
By-Pass Length
By-Pass Pumping Information
Street Width 28
Quantity of Street Repair (LF) 80.00
Street Repair Data
30% Package Number 2
Reason Selected for 30% Other E
Reviewed in 10% Design Yes
Base or Additional Pipe Additional Pipe
On CPMS Project No
Avg Day (MGD)- From Model for Pipes > 12"
NOT FOR CONSTRUCTION
THIS DOCUMENT IS RELEASED FOR THEPURPOSE OF INTERIM REVIEW UNDER THEAUTHORITY OF: TADEUSZ J. STAWASZ TEXAS NO:102666 ON DATE: 7/13/18IT IS NOT TO BE USED FOR CONSTRUCTION,BIDDING OR PERMINT PURPOSE.
Depth: 6.1Rim: 667.45
UnitID: 14395
Depth: 4.44Rim: 670
UnitID: 13728
Depth: 3.29Rim: 670
UnitID: 29577
Depth: 5.97Rim: 669.43
UnitID: 143918", 362.3 LFCompkey: 990768
8", 3
99.2
LFCo
mpke
y: 99
0876
PECHE (95)
RIVAS ST (60)
COLORADO ALLEY (21)
DELGADO ST (21)
RIVAS ST (71)
ARBOR PLACE (46)
N SM
ITH S
T (88
)
SMITH
ALL
EY (8
6)
DELGADO ST (88)
N BR
AZOS
ST (
43)
RIVAS ST (82)
N BR
AZOS
ST (
76)
ARBOR PLACE (71)
N BR
AZOS
ST (
39)
N BR
AZOS
ST (
54)
RIVAS ST (78)
N BR
AZOS
ST (
71)
DELGADO ST (85)DELGADO ST (90)
N CO
LORA
DO S
T (94
)N
COLO
RADO
ST(93
)
ARBOR PLACE (81)
12"
6"
8"
8"
12"
6"
12"
8"
8"
8"
12"
8"
8"
8"
8"
8"
8"
8"
670'
670'
670'
Depth: 3.1Rim: 672
UnitID: 11849
Depth: 6.7Rim: 670
UnitID: 11475
Depth: 5.11Rim: 668
UnitID: 14358
Depth: 6.03Rim: 670
UnitID: 11476
Depth: 5.09Rim: 670
UnitID: 11478
Depth: 3.12Rim: 670
UnitID: 29578
Depth: 5.19Rim: 670
UnitID: 14357
Depth: 4.94Rim: 668
UnitID: 13696
Depth: 4.79Rim: 668.63
UnitID: 14390
Depth: 5.72Rim: 669.12
UnitID: 11487
Depth: 5.04Rim: 665.73
UnitID: 14381
Depth: 5.28Rim: 667.82
UnitID: 14382
Source: Esri, DigitalGlobe, GeoEye, Earthstar Geographics, CNES/Airbus DS, USDA, USGS, AeroGRID, IGN, and the GISUser Community
Date:
Crea
ted By
Free
se an
d Nich
ols, In
c.Jo
b No.:
SWB
1640
6Lo
catio
n: P:\
gis\FA
NI16
0013
8\30%
Con
dition
Sma
ll Diam
eter P
kgs\C
PY_P
acka
ge2\0
5_Ma
p_Bo
ok.m
xdUp
dated
: Mon
day,
July
02, 2
018 9
:06:10
AM
LEGEND!( Manhole
CIPPCIPP & POINT REPAIRBOREPIPEBURSTPIPEBURST & POINT REPAIRREPLACE OPEN-CUTCPS Electric OH PrimaryCPS Gas Distribution MainAdditional Line
! Potential Point Repair Location
8" and SmallerWastewater Line10" and LargerWastewater LineWater MainLateralsRoadStream10-ft ContourParcel100Yr Floodplains
Project
I0 100 200
SCALE IN FEET
Title: Compkey: 990876 & 990768
SSO Basin Planning Consultant30% Condition Small Diameter
7/11/2018
3
Sheet C-3NOT FOR
CONSTRUCTIONThis document is release fo the purpose of interim review under the authority of: Tadeus J. StawaszTexas No. 102666 on Date: 7/13/18.It is not to be used for construction, bidding, or permint purpose.
ASSET INFORMATION SHEET F-3a
Diameter 8
Length 399.20
Length Surveyed 387.70
75% Televised
No of Laterals 9
Material CT
VerifiedCondition E
Condition (Consultant)Siphon #
Sag No No of Point Repairs 0
CompKey 990876
Final Rehab PIPEBURST
Basin CENTRAL
Upstream MH 29577
Downstream MH 13728
US Depth 3.29
DS Depth 4.44
YesConstruction Access N Brazos St
YesOperational Access N Brazos St
Jurisdictional Water No
NAEndangered Species
Karst Zones NA
NACritical Habitat
NAEnvironmental factors
NAHazardous Sites
NAArcheolgical Sites
Geomorphology Issues NA
Geotechnical issues NA
Exist Utilities Parallel 8" water main, parallel 12" gas main, crosses 2" gas main, crosses 6" water main, OHE, underground communication cables (three Broadwing Communications access manholes along Brazos St). MH #13728 is near railroad tracks.
Yes
YesPermit Conditions CoSA ROW (N Brazos St)
Available Grade
Available Cover
Large Trees
Site Access by Combo Truck
Crosses Creek, TxDOT Rd, or Bridge
Large WTR Mains
Large Gas Mains
Easement Required (number of parcels)
0
Point Repair Identified by a ProfessionalNo
By-Pass Info
Lateral Only
Peak Wet Weather (MGD) 0.42- From Model for Pipes > 12"- Calculated for Pipes < 12" with Mannings Assuming Full Flow
US Suction Manhole N/A
DS Discharge Manhole N/A
By-Pass Length
By-Pass Pumping Information
Street Width 28
Quantity of Street Repair (LF) 399.20
Street Repair Data
30% Package Number 2
Reason Selected for 30% Low Income E
Reviewed in 10% Design Yes
Base or Additional Pipe Base Pipe
On CPMS Project No
Avg Day (MGD)- From Model for Pipes > 12"
NOT FOR CONSTRUCTION
THIS DOCUMENT IS RELEASED FOR THEPURPOSE OF INTERIM REVIEW UNDER THEAUTHORITY OF: TADEUSZ J. STAWASZ TEXAS NO:102666 ON DATE: 7/13/18IT IS NOT TO BE USED FOR CONSTRUCTION,BIDDING OR PERMINT PURPOSE.
ASSET INFORMATION SHEET F-3b
Diameter 8
Length 362.30
Length Surveyed 362.60
75% Televised
No of Laterals 9
Material CT
VerifiedCondition E
Condition (Consultant)Siphon #
Sag No No of Point Repairs 0
CompKey 990768
Final Rehab REPLACE OPEN-CUT
Basin CENTRAL
Upstream MH 13728
Downstream MH 14391
US Depth 4.47
DS Depth 5.97
YesConstruction Access Located in the ROW of Delgado St
YesOperational Access Located in the ROW of Delgado St
Jurisdictional Water None likely.No
NoEndangered Species None likely.
Karst Zones Within karst zone 5. No action required.No
NoCritical Habitat No wetlands mapped.
NoEnvironmental factors Not within Edwards Aquifer. No action required.
Hazardous Sites Haven for Hope, located southeast of the segment, lists GWCC and VCP sites. Alazan Apache Property located immediately adjacent to segment and lists IHWCA. Recommend field investigation for any unreported sites and/or dumps.
NoArcheolgical Sites No known cultural resources conflict. Coordination with CoSA OHP needed. If work will exceed five acres or 5,000 cubic yards of earth moving, consultation with THC needed.
Geomorphology Issues Potential Ground Water May be EncounteredYes
Geotechnical issues Geology: Terrace Deposit, Rock Excavation Equipment May Not be Required, Potential Sloughing and Caving May Occur
Yes
Exist Utilities Parallel 8" water main and 2" gas main, large OHE transmission mainsYes
YesPermit Conditions COSA for Delgado
Available Grade
Available Cover
Large Trees
Site Access by Combo Truck
Crosses Creek, TxDOT Rd, or Bridge
Large WTR Mains
Large Gas Mains
Easement Required (number of parcels)
0
Point Repair Identified by a ProfessionalNo
By-Pass Info
Peak Wet Weather (MGD) 0.30- From Model for Pipes > 12"- Calculated for Pipes < 12" with Mannings Assuming Full Flow
US Suction Manhole 29577
DS Discharge Manhole 14395
By-Pass Length 1115
By-Pass Pumping Information
Street Width 28
Quantity of Street Repair (LF) 362.30
Street Repair Data
30% Package Number 2
Reason Selected for 30% Low Income E
Reviewed in 10% Design Yes
Base or Additional Pipe Base Pipe
On CPMS Project No
Avg Day (MGD)- From Model for Pipes > 12"
NOT FOR CONSTRUCTION
THIS DOCUMENT IS RELEASED FOR THEPURPOSE OF INTERIM REVIEW UNDER THEAUTHORITY OF: TADEUSZ J. STAWASZ TEXAS NO:102666 ON DATE: 7/13/18IT IS NOT TO BE USED FOR CONSTRUCTION,BIDDING OR PERMINT PURPOSE.
Depth: 11.8Rim: 697.79
UnitID: 18270
Depth: 11.23Rim: 696.35
UnitID: 34645
Depth: 10.39Rim: 696.54
UnitID: 18732 Depth: 11.22Rim: 696.54
UnitID: 1856510", 284.3 LFCompkey: 992512
MOTES DR (56)
ROME
RO (8
1)
S SAN
IGNA
CIO
(21)
MORA
IMA
ST (6
7)
ROME
RO (6
9)
S SAN
JOAQ
UIN
(74)
DAHL
GREE
N AV
E (57
)
S SAN
IGNA
CIO
(45)
WALLACE ST (61)
S SAN
JOAQ
UIN
(76)
ELDRIDGE AVE (36)
S SAN
JOAQ
UIN
(77)
ELDRIDGE AVE (29)
WALLACE ST (68)
WALL (68)
WALLACE ST (67)
ELDRIDGE AVE (36)
6"
8"
8"
6"
6"
6"
6"
8"
6"
6"
6"
8"8"
6"
6"
8"
12"
10"
10"
12"
10"
10"
10"
10"10"
10"
12"
10"
8"
700'
Depth: 0Rim: 692
UnitID: 34643
Depth: 0Rim: 698
UnitID: 18736Depth: 0Rim: 698
UnitID: 18276
Depth: 0Rim: 696
UnitID: 18731
Depth: 5.64Rim: 698
UnitID: 18728
Depth: 9.47Rim: 696
UnitID: 18568Depth: 10.34
Rim: 696UnitID: 18569
Depth: 9.56Rim: 694.08
UnitID: 34646
Depth: 9.56Rim: 694.08
UnitID: 18268
Depth: 10.39Rim: 696.54
UnitID: 18271
Source: Esri, DigitalGlobe, GeoEye, Earthstar Geographics, CNES/Airbus DS, USDA, USGS, AeroGRID, IGN, and the GISUser Community
Date:
Crea
ted By
Free
se an
d Nich
ols, In
c.Jo
b No.:
SWB
1640
6Lo
catio
n: P:\
gis\FA
NI16
0013
8\30%
Con
dition
Sma
ll Diam
eter P
kgs\C
PY_P
acka
ge2\0
5_Ma
p_Bo
ok.m
xdUp
dated
: Mon
day,
July
02, 2
018 9
:06:50
AM
LEGEND!( Manhole
CIPPCIPP & POINT REPAIRBOREPIPEBURSTPIPEBURST & POINT REPAIRREPLACE OPEN-CUTCPS Electric OH PrimaryCPS Gas Distribution MainAdditional Line
! Potential Point Repair Location
8" and SmallerWastewater Line10" and LargerWastewater LineWater MainLateralsRoadStream10-ft ContourParcel100Yr Floodplains
Project
I0 100 200
SCALE IN FEET
Title: Compkey: 992512
SSO Basin Planning Consultant30% Condition Small Diameter
7/11/2018
4
Sheet C-4NOT FOR
CONSTRUCTIONThis document is release fo the purpose of interim review under the authority of: Tadeus J. StawaszTexas No. 102666 on Date: 7/13/18.It is not to be used for construction, bidding, or permint purpose.
ASSET INFORMATION SHEET F-4
Diameter 10
Length 284.30
Length Surveyed 222.00
75% Televised
No of Laterals 2
Material VCP
VerifiedCondition E
Condition (Consultant)Siphon #
Sag No No of Point Repairs
CompKey 992512
Final Rehab REPLACE OPEN-CUT
Basin CENTRAL
Upstream MH 18732
Downstream MH 18565
US Depth 10.39
DS Depth 11.22
YesConstruction Access Located in ROW of Eldridge Ave
YesOperational Access
Jurisdictional Water None likely.No
NoEndangered Species None likely.
Karst Zones Within karst zone 5. No action required.No
NoCritical Habitat No wetlands mapped.
NoEnvironmental factors Not within Edwards Aquifer. No action required.
YesHazardous Sites ERNSTX site atop segment indicates that rifle cartridges and lead were dumped and buried within the surrounding soil. SEMS site Eldridge Avenue Lead Site is west of segment lists extensive lead contamination of soil. Recommend lead testing in soil around segment. Recommend field investigation for any unreported sites and/or dumps.
NoArcheolgical Sites No known cultural resources conflict. Coordination with CoSA OHP needed. If work will exceed five acres or 5,000 cubic yards of earth moving, consultation with THC needed.
Geomorphology Issues Potential Ground Water May be EncounteredYes
Geotechnical issues Geology: Terrace Deposit, Rock Excavation Equipment May Not be Required, Potential Sloughing and Caving May Occur
Yes
Exist Utilities OHE, Parallel 8" water mainYes
YesPermit Conditions COSA for Eldridge Ave
Available Grade
Available Cover
Large Trees
Site Access by Combo Truck
Crosses Creek, TxDOT Rd, or Bridge
Large WTR Mains
Large Gas Mains
Easement Required (number of parcels)
0
Point Repair Identified by a ProfessionalNo
By-Pass Info
Peak Wet Weather (MGD) 0.77- From Model for Pipes > 12"- Calculated for Pipes < 12" with Mannings Assuming Full Flow
US Suction Manhole 18270
DS Discharge Manhole 34645
By-Pass Length 660
By-Pass Pumping Information
Street Width 28
Quantity of Street Repair (LF) 284.30
Street Repair Data
30% Package Number 2
Reason Selected for 30% Low Income E
Reviewed in 10% Design Yes
Base or Additional Pipe Base Pipe
On CPMS Project No
Avg Day (MGD)- From Model for Pipes > 12"
NOT FOR CONSTRUCTION
THIS DOCUMENT IS RELEASED FOR THEPURPOSE OF INTERIM REVIEW UNDER THEAUTHORITY OF: TADEUSZ J. STAWASZ TEXAS NO:102666 ON DATE: 7/13/18IT IS NOT TO BE USED FOR CONSTRUCTION,BIDDING OR PERMINT PURPOSE.
MH 23340 located further upstream.
Depth: 6.21Rim: 632
UnitID: 23155
Depth: 11.46Rim: 636.8
UnitID: 23231
Depth: 13.6Rim: 637.72
UnitID: 38159
8", 4
09 LF
Comp
key:
9810
81
8", 3
93 LF
Comp
key:
9810
68
GUADALUPE ST (0)
EL PASO ST (39)
S COM
AL S
T (94
)
S COM
AL S
T (48
)
BUCK
BERR
Y (21
)
S RIC
HTER
ST (
18)
S SAL
ADO
ST (2
1)
S SAN
MAR
COS (
54)
S SAN
MAR
COS (
57)
GUADALUPE ST (81)
SAN FERNANDO ST (44)
GUS GARCIA (89)
TORR
EON
(91)
SAN FERNANDO ST (80)
EL PASO ST (24)
GUADALUPE ST (64)
GUADALUPE ST (90)
S COM
AL S
T (95
)
EL PASO ST (82)
EL PASO ST (22) EL PASO ST (20)
SAN FERNANDO ST (21)S R
ICHT
ER S
T (52
)S R
ICHT
ER S
T (26
)
EL PASO ST (38)
TORREON (73)
S COM
AL ST
(42)
GUADALUPE ST (74)
GUADALUPE ST (81) GUADALUPE ST (0)
GUADALUPE ST (0)
EL PASO ST (82)
8"
6"
6"
8"
6"
6"
42"
12"
15"
42"
42"
42"
42"
42"
42"
42"
42"
42"
15"
42"
8"
8"8"
8"
8"8"
8"
8"8"
8"
8"
8"
8"8"
Alaza
n Cree
kAl
azan C
reek
620'
630'
640'
620'
630'
Depth: 4.8Rim: 644
UnitID: 23235Depth: 9.1Rim: 642
UnitID: 23341
Depth: 4.66Rim: 640
UnitID: 38270
Depth: 8.2Rim: 635.5
UnitID: 23148
Depth: 8.58Rim: 639.33
UnitID: 23569
Depth: 6.32Rim: 648.37
UnitID: 25514Depth: 7.35Rim: 632.37
UnitID: 23185
Depth: 6.44Rim: 635.01
UnitID: 488504
Depth: 12.88Rim: 636.81
UnitID: 23184
SAN ANTONIO HOUSING AUTHORITY3.06 Acres
Source: Esri, DigitalGlobe, GeoEye, Earthstar Geographics, CNES/Airbus DS, USDA, USGS, AeroGRID, IGN, and the GISUser Community
Date:
Crea
ted By
Free
se an
d Nich
ols, In
c.Jo
b No.:
SWB
1640
6Lo
catio
n: P:\
gis\FA
NI16
0013
8\30%
Con
dition
Sma
ll Diam
eter P
kgs\C
PY_P
acka
ge2\0
5_Ma
p_Bo
ok.m
xdUp
dated
: Mon
day,
July
02, 2
018 9
:07:37
AM
LEGEND!( Manhole
CIPPCIPP & POINT REPAIRBOREPIPEBURSTPIPEBURST & POINT REPAIRREPLACE OPEN-CUTCPS Electric OH PrimaryCPS Gas Distribution MainAdditional Line
! Potential Point Repair Location
8" and SmallerWastewater Line10" and LargerWastewater LineWater MainLateralsRoadStream10-ft ContourParcel100Yr Floodplains
Project
I0 100 200
SCALE IN FEET
Title: Compkey: 981068 & 981081
SSO Basin Planning Consultant30% Condition Small Diameter
7/11/2018
5
Sheet C-5NOT FOR
CONSTRUCTIONThis document is release fo the purpose of interim review under the authority of: Tadeus J. StawaszTexas No. 102666 on Date: 7/13/18.It is not to be used for construction, bidding, or permint purpose.
ASSET INFORMATION SHEET F-5a
Diameter 8
Length 393.00
Length Surveyed 383.60
75% Televised
No of Laterals 1
Material VCP
VerifiedCondition E
Condition (Consultant)Siphon #
Sag yes No of Point Repairs 2
CompKey 981068
Final Rehab PIPEBURST & POINT REPAIR
Basin CENTRAL
Upstream MH 23155
Downstream MH 23231
US Depth 6.21
DS Depth 11.46
NoConstruction Access located behind a fenced commercial property. MHs are UTL
NoOperational Access located behind a fenced commercial propertu
Jurisdictional Water Alazan CreekYes
NAEndangered Species
Karst Zones NA
NACritical Habitat
NAEnvironmental factors
NAHazardous Sites
NAArcheolgical Sites
Geomorphology Issues NA
Geotechnical issues NA
Exist Utilities No
NoPermit Conditions
Available Grade
Available Cover
Large Trees
Site Access by Combo Truck
Crosses Creek, TxDOT Rd, or Bridge
Large WTR Mains
Large Gas Mains
Easement Required (number of parcels)
2
Point Repair Identified by a Professionalyes
By-Pass Info
Peak Wet Weather (MGD) 0.90- From Model for Pipes > 12"- Calculated for Pipes < 12" with Mannings Assuming Full Flow
US Suction Manhole 23340
DS Discharge Manhole 23184
By-Pass Length 1075
By-Pass Pumping Information
Street Width 36
Quantity of Street Repair (LF) 40.00
Street Repair Data
30% Package Number 2
Reason Selected for 30% Other E
Reviewed in 10% Design Yes
Base or Additional Pipe Additional Pipe
On CPMS Project No
Avg Day (MGD)- From Model for Pipes > 12"
NOT FOR CONSTRUCTION
THIS DOCUMENT IS RELEASED FOR THEPURPOSE OF INTERIM REVIEW UNDER THEAUTHORITY OF: TADEUSZ J. STAWASZ TEXAS NO:102666 ON DATE: 7/13/18IT IS NOT TO BE USED FOR CONSTRUCTION,BIDDING OR PERMINT PURPOSE.
ASSET INFORMATION SHEET F-5b
Diameter 8
Length 409.00
Length Surveyed 421.90
75% Televised
No of Laterals 1
Material VCP
VerifiedCondition E
Condition (Consultant)Siphon #
Sag yes No of Point Repairs 0
CompKey 981081
Final Rehab PIPEBURST
Basin CENTRAL
Upstream MH 23231
Downstream MH 38159
US Depth 11.46
DS Depth 13.6
YesConstruction Access El Paso St
YesOperational Access El Paso St. Pipe crosses along bank of Alazan Creek and under two street bridges. MH #23231 is located under brush near the El Paso St bridge. MH #38159 is located beneath the Guadalupe St bridge. Unable to locate MHs.
Jurisdictional Water Alazan CreekYes
NAEndangered Species
Karst Zones NA
NACritical Habitat
NAEnvironmental factors
NAHazardous Sites
NAArcheolgical Sites
Geomorphology Issues NA
Geotechnical issues NA
Exist Utilities Crosses 8" water main. Power lines along Alazan Creek significantly sagging, hanging only 3-4 feet above ground, nearby storm sewer MH
Yes
YesPermit Conditions CoSA ROW (El Paso St and Guadalupe St, floodplain development permit, SARA, USACE)
Available Grade
Available Cover
Large Trees
Site Access by Combo Truck
Crosses Creek, TxDOT Rd, or Bridge
Large WTR Mains
Large Gas Mains
Easement Required (number of parcels)
0
Point Repair Identified by a Professionalyes
By-Pass Info
Refer to F Sheet for COMPKEY 981068
Peak Wet Weather (MGD) 0.56- From Model for Pipes > 12"- Calculated for Pipes < 12" with Mannings Assuming Full Flow
US Suction Manhole *
DS Discharge Manhole *
By-Pass Length
By-Pass Pumping Information
Street Width 24
Quantity of Street Repair (LF) 409.00
Street Repair Data
30% Package Number 2
Reason Selected for 30% Other E
Reviewed in 10% Design Yes
Base or Additional Pipe Additional Pipe
On CPMS Project No
Avg Day (MGD)- From Model for Pipes > 12"
NOT FOR CONSTRUCTION
THIS DOCUMENT IS RELEASED FOR THEPURPOSE OF INTERIM REVIEW UNDER THEAUTHORITY OF: TADEUSZ J. STAWASZ TEXAS NO:102666 ON DATE: 7/13/18IT IS NOT TO BE USED FOR CONSTRUCTION,BIDDING OR PERMINT PURPOSE.
Depth: 8.74Rim: 655.34
UnitID: 34916
Depth: 11Rim: 658
UnitID: 19414
Depth: 10.75Rim: 658
UnitID: 16499
12", 383.8 LF
Compkey: 978096
TAFT BLVD (82)
FRIO CITY RD (93)
DARBY BLVD (65)
KIRK PLACE (71)
DARBY BLVD (0)
HARRIMAN PLACE (71)
FRIO CITY RD (92)
KIRK PLACE (96)
S ZAR
ZAMO
RA (8
0)
S ZAR
ZAMO
RA (8
6)
FRIO CITY RD (96)
KIRK PLACE (81)
S ZAR
ZAMO
RA (4
4)
PHYL
LI SST
(82)
FRIO CITY RD (94)
S ZAR
ZAMO
RA (6
1)
FRIO CITY RD (94)
8"
12"
6"
4"
4"
6"12"
8"
12"
12"
6"
12"
6"6"
6"
6"
12"
10"10"
12"
12"
12"
10" 10"
12"
12"
12"
10"
10"
12"
12"
8"
8"
8"
8"
8"
8"
8"8"
8"
8"8"
8"
660'
660'
660'Depth: 0Rim: 656
UnitID: 16429
Depth: 0Rim: 656
UnitID: 19409
Depth: 0Rim: 658
UnitID: 19974
Depth: 0Rim: 658
UnitID: 19653
Depth: 8.25Rim: 656
UnitID: 16431
Depth: 8.35Rim: 658
UnitID: 16440
Depth: 7.89Rim: 656
UnitID: 19971
Depth: 9.93Rim: 655.8
UnitID: 34915
Depth: 6.36Rim: 654.27
UnitID: 480426
Depth: 5.74Rim: 655.75
UnitID: 480424Depth: 6.37Rim: 655.11
UnitID: 480425
Depth: 5.12Rim: 654.95
UnitID: 480439
UNION PACIFIC RAILROAD CO11.83 Acres
Source: Esri, DigitalGlobe, GeoEye, Earthstar Geographics, CNES/Airbus DS, USDA, USGS, AeroGRID, IGN, and the GISUser Community
Date:
Crea
ted By
Free
se an
d Nich
ols, In
c.Jo
b No.:
SWB
1640
6Lo
catio
n: P:\
gis\FA
NI16
0013
8\30%
Con
dition
Sma
ll Diam
eter P
kgs\C
PY_P
acka
ge2\0
5_Ma
p_Bo
ok.m
xdUp
dated
: Mon
day,
July
02, 2
018 9
:08:19
AM
LEGEND!( Manhole
CIPPCIPP & POINT REPAIRBOREPIPEBURSTPIPEBURST & POINT REPAIRREPLACE OPEN-CUTCPS Electric OH PrimaryCPS Gas Distribution MainAdditional Line
! Potential Point Repair Location
8" and SmallerWastewater Line10" and LargerWastewater LineWater MainLateralsRoadStream10-ft ContourParcel100Yr Floodplains
Project
I0 100 200
SCALE IN FEET
Title: Compkey: 978096
SSO Basin Planning Consultant30% Condition Small Diameter
7/11/2018
6
Sheet C-6NOT FOR
CONSTRUCTIONThis document is release fo the purpose of interim review under the authority of: Tadeus J. StawaszTexas No. 102666 on Date: 7/13/18.It is not to be used for construction, bidding, or permint purpose.
ASSET INFORMATION SHEET F-6
Diameter 12
Length 383.80
Length Surveyed 370.00
75% Televised
No of Laterals 1
Material CP
VerifiedCondition E
Condition (Consultant)Siphon #
Sag No No of Point Repairs
CompKey 978096
Final Rehab REPLACE OPEN-CUT
Basin CENTRAL
Upstream MH 16499
Downstream MH 19414
US Depth 10.75
DS Depth 11
YesConstruction Access Located in ROW of Frio City Road
TesOperational Access Located in ROW of Frio City Road
Jurisdictional Water None likely.No
NoEndangered Species None likely.
Karst Zones Within karst zone 5. No action required.No
NoCritical Habitat No wetlands mapped.
NoEnvironmental factors Not within Edwards Aquifer. No action required.
YesHazardous Sites Segment adjacent to CALF site named “Zarzamora.” No further information on the size, age, and contents of site. Recommend further research into facility to assess risk to segment. Recommend field investigation for any unreported sites and/or dumps.
NoArcheolgical Sites No known cultural resources conflict. Coordination with CoSA OHP needed. If work will exceed five acres or 5,000 cubic yards of earth moving, consultation with THC needed.
Geomorphology Issues Potential Ground Water May be EncounteredYes
Geotechnical issues Geology: Terrace Deposit, Rock Excavation Equipment May Not be Required, Potential Sloughing and Caving May Occur
Yes
Exist Utilities Parallel 12" gas main and crosses 12" water mainYes
YesPermit Conditions COSA for Frio City Road
Available Grade
Available Cover
Large Trees
Site Access by Combo Truck
Crosses Creek, TxDOT Rd, or Bridge
Large WTR Mains
Large Gas Mains
Easement Required (number of parcels)
0
Point Repair Identified by a ProfessionalNo
By-Pass Info
Peak Wet Weather (MGD) 1.59- From Model for Pipes > 12"- Calculated for Pipes < 12" with Mannings Assuming Full Flow
US Suction Manhole 16431
DS Discharge Manhole 34916
By-Pass Length 945
By-Pass Pumping Information
Street Width 46
Quantity of Street Repair (LF) 383.80
Street Repair Data
30% Package Number 2
Reason Selected for 30% Concrete E
Reviewed in 10% Design Yes
Base or Additional Pipe Base Pipe
On CPMS Project No
Avg Day (MGD) 0.73- From Model for Pipes > 12"
NOT FOR CONSTRUCTION
THIS DOCUMENT IS RELEASED FOR THEPURPOSE OF INTERIM REVIEW UNDER THEAUTHORITY OF: TADEUSZ J. STAWASZ TEXAS NO:102666 ON DATE: 7/13/18IT IS NOT TO BE USED FOR CONSTRUCTION,BIDDING OR PERMINT PURPOSE.
0 317 701 982
16431
16499
19414
16431
656.000
-3.824
16499
658.000
-7.376
19414
658.000
-9.248
34916
655.340
-8.389
16431.1
12.0
647.750
647.251
0.157
0.91
64-08
2.00
1.5895
2.792
16499.1
978096
12.0
647.251
647.000
0.065
0.59
64-08
2.00
1.5895
2.860
19414.1
12.0
647.000
646.601
0.142
0.87
64-08
2.00
1.5977
2.989
Node
ground (ft AD)
flood dep (ft)
Link
Asset ID
width (in)
us inv (ft AD)
ds inv (ft AD)
grad (%)
pfc (MGD)
CC Project Area ID
CC Alternative
surc
US flow (MGD)
US velocity (ft/s)
646.0
659.0
647.0
648.0
649.0
650.0
651.0
652.0
653.0
654.0
655.0
656.0
657.0
658.0
ft A
D
ft
P-6
SAN ANTONIO WATER SYSTEMCONDITION 30% DESIGN
PROFILE 6: COMPKEY ID 978096
LEGEND
Flow Level
2-ft ContoursManhole Rim Elevation
Ground Elevation Based on:
Depth: 6.22Rim: 601.41
UnitID: 27973
MH 42463 locatedfurther upstream.
Depth: 6.7Rim: 612.86
UnitID: 42465
Depth: 4.8Rim: 613.39
UnitID: 42464
POOL DR (30)
SUBLETT DR (40)
BOB BIL
LA(66
)
HOWERTON DR (38)
PECAN VALLEY DR (81)
PECAN VALLEY DR (80)
POOL DR (18)
PECA
N VA
LLEY
DR
(79)
KELLIS AVE (49)KELLIS AVE (58)
POOL DR (89)
PECA
N VA
LLEY
DR
(81)
PECAN VA
LLEY
DR(81
)PE
CAN VA
LLEY
DR(79
)
8"
6"
6"
6"
8"
6"
8"
6"
6"
8"
6"
8"
8"
6"
6"
8"
6"
6"
6"
8"
6"
6"6"
6"
6"
48"
48"
48"
48"
48"
8"
8" 8"
8"
8"
8"
8"
8"
8"
8"
8"
8"
8"
8"
8"
8"
8"
8"
8"
8"
8" 8"
8"
8"
8"
8"
UNNA
MED ST
REAM
UNNA
MED ST
REAM
Depth: 6.47Rim: 588
UnitID: 29056
Depth: 9.98Rim: 606
UnitID: 29596
Depth: 5.14Rim: 590
UnitID: 29516
Depth: 7.67Rim: 594
UnitID: 353892
Depth: 6.14Rim: 592
UnitID: 353893
Depth: 8.83Rim: 589.7
UnitID: 29513Depth: 6.5Rim: 590.5
UnitID: 353894
Depth: 5.7Rim: 635.08
UnitID: 28155
Depth: 7.3Rim: 582.94
UnitID: 29026
Depth: 6.4Rim: 584.64
UnitID: 42893
Depth: 7.65Rim: 605.15
UnitID: 29053
Depth: 7.46Rim: 590.3
UnitID: 353895
Depth: 4.01Rim: 590.78
UnitID: 29057
Depth: 7.89Rim: 608.81
UnitID: 28173Depth: 8.08Rim: 603.39
UnitID: 42006
Depth: 6.25Rim: 604.25
UnitID: 29483
Depth: 6.95Rim: 602.39
UnitID: 27974
Depth: 12.4Rim: 607.75
UnitID: 28130
Depth: 9.14Rim: 614.26
UnitID: 28161Depth: 5.18Rim: 618.79
UnitID: 28160
EPWORTH UNITED METHODIST CHURCH4.47 Acres
8", 94 LFCompkey: 1066449
Source: Esri, DigitalGlobe, GeoEye, Earthstar Geographics, CNES/Airbus DS, USDA, USGS, AeroGRID, IGN, and the GISUser Community
Date:
Crea
ted By
Free
se an
d Nich
ols, In
c.Jo
b No.:
SWB
1640
6Lo
catio
n: P:\
gis\FA
NI16
0013
8\30%
Con
dition
Sma
ll Diam
eter P
kgs\C
PY_P
acka
ge2\0
5_Ma
p_Bo
ok.m
xdUp
dated
: Mon
day,
July
02, 2
018 9
:09:00
AM
LEGEND!( Manhole
CIPPCIPP & POINT REPAIRBOREPIPEBURSTPIPEBURST & POINT REPAIRREPLACE OPEN-CUTCPS Electric OH PrimaryCPS Gas Distribution MainAdditional Line
! Potential Point Repair Location
8" and SmallerWastewater Line10" and LargerWastewater LineWater MainLateralsRoadStream10-ft ContourParcel100Yr Floodplains
Project
I0 100 200
SCALE IN FEET
Title: Compkey: 1066449
SSO Basin Planning Consultant30% Condition Small Diameter
7/11/2018
7
Sheet C-7NOT FOR
CONSTRUCTIONThis document is release fo the purpose of interim review under the authority of: Tadeus J. StawaszTexas No. 102666 on Date: 7/13/18.It is not to be used for construction, bidding, or permint purpose.
ASSET INFORMATION SHEET F-7
Diameter 8
Length 94.00
Length Surveyed 87.70
75% Televised
No of Laterals 1
Material CP
VerifiedCondition E
Condition (Consultant)Siphon #
Sag No No of Point Repairs 0
CompKey 1066449
Final Rehab PIPEBURST
Basin CENTRAL
Upstream MH 42464
Downstream MH 42465
US Depth 4.8
DS Depth 6.7
YesConstruction Access Pecan Valley Dr
YesOperational Access Alley between Howerton Dr and Sublett Dr along Pecan Valley Dr. MH #42465 is located in median of Pecan Valley Dr with steep slope. MH #42464 is located in the alley in front of residential driveway.
Jurisdictional Water No
NAEndangered Species
Karst Zones NA
NACritical Habitat
NAEnvironmental factors
NAHazardous Sites
NAArcheolgical Sites
Geomorphology Issues NA
Geotechnical issues NA
Exist Utilities Parallel 2" gas main, crosses 6" water main, OHEYes
YesPermit Conditions CoSA ROW (Pecan Valley Dr and alley)
Available Grade
Available Cover
Large Trees
Site Access by Combo Truck
Crosses Creek, TxDOT Rd, or Bridge
Large WTR Mains
Large Gas Mains
Easement Required (number of parcels)
0
Point Repair Identified by a ProfessionalYes
By-Pass Info
Address all laterals upstream
Peak Wet Weather (MGD) 1.11- From Model for Pipes > 12"- Calculated for Pipes < 12" with Mannings Assuming Full Flow
US Suction Manhole 42463
DS Discharge Manhole 27973
By-Pass Length 200
By-Pass Pumping Information
Street Width 28
Quantity of Street Repair (LF) 94.00
Street Repair Data
30% Package Number 2
Reason Selected for 30% Concrete E
Reviewed in 10% Design Yes
Base or Additional Pipe Base Pipe
On CPMS Project No
Avg Day (MGD)- From Model for Pipes > 12"
NOT FOR CONSTRUCTION
THIS DOCUMENT IS RELEASED FOR THEPURPOSE OF INTERIM REVIEW UNDER THEAUTHORITY OF: TADEUSZ J. STAWASZ TEXAS NO:102666 ON DATE: 7/13/18IT IS NOT TO BE USED FOR CONSTRUCTION,BIDDING OR PERMINT PURPOSE.
Depth: 11.94Rim: 651.7
UnitID: 19433
Depth: 11.9Rim: 650.8
UnitID: 18872Depth: 10.54Rim: 649.2
UnitID: 18874
15", 399.2 LFCompkey: 984923 W MAYFIELD (99)
WABASH ST (58)
W MAYFIELD (99)15"
24"
12"
10"10"
10" 15"
24"
15"15"
12"
8"8" 8"
8"8"
Six Mile CreekSix Mile Creek
Six M
ile C
reek
Six M
ile C
reek
Depth: 6.4Rim: 651
UnitID: 91642
Depth: 5Rim: 649.09
UnitID: 19434
Depth: 6.4Rim: 649.8
UnitID: 91643
Depth: 10.67Rim: 650
UnitID: 940331
Depth: 11.65Rim: 648.8
UnitID: 92168
Depth: 11.59Rim: 650.8
UnitID: 18871
Depth: 4.65Rim: 649.47
UnitID: 19310
GUILD PARK LP4.51 Acres
SAN ANTONIO SHOE INC11.18 Acres
Source: Esri, DigitalGlobe, GeoEye, Earthstar Geographics, CNES/Airbus DS, USDA, USGS, AeroGRID, IGN, and the GISUser Community
Date:
Crea
ted By
Free
se an
d Nich
ols, In
c.Jo
b No.:
SWB
1640
6Lo
catio
n: P:\
gis\FA
NI16
0013
8\30%
Con
dition
Sma
ll Diam
eter P
kgs\C
PY_P
acka
ge2\0
5_Ma
p_Bo
ok.m
xdUp
dated
: Mon
day,
July
02, 2
018 9
:09:40
AM
LEGEND!( Manhole
CIPPCIPP & POINT REPAIRBOREPIPEBURSTPIPEBURST & POINT REPAIRREPLACE OPEN-CUTCPS Electric OH PrimaryCPS Gas Distribution MainAdditional Line
! Potential Point Repair Location
8" and SmallerWastewater Line10" and LargerWastewater LineWater MainLateralsRoadStream10-ft ContourParcel100Yr Floodplains
Project
I0 100 200
SCALE IN FEET
Title: Compkey: 984923
SSO Basin Planning Consultant30% Condition Small Diameter
7/11/2018
8
Sheet C-8NOT FOR
CONSTRUCTIONThis document is release fo the purpose of interim review under the authority of: Tadeus J. StawaszTexas No. 102666 on Date: 7/13/18.It is not to be used for construction, bidding, or permint purpose.
ASSET INFORMATION SHEET F-8
Diameter 15
Length 399.20
Length Surveyed 164.00
75% Televised
No of Laterals 2
Material CP
VerifiedCondition E
Condition (Consultant)Siphon #
Sag No No of Point Repairs
CompKey 984923
Final Rehab REPLACE OPEN-CUT
Basin CENTRAL
Upstream MH 18872
Downstream MH 18874
US Depth 11.9
DS Depth 10.54
YesConstruction Access Located in ROW of W Mayfield
YesOperational Access Located in ROW of W Mayfield
Jurisdictional Water Adjacent to Six mile Creek. Recommend field investigation to determine presence of unmapped waters and wetlands.
Yes
NoEndangered Species None likely.
Karst Zones Not within a karst zone. No action required.No
NoCritical Habitat No wetlands mapped.
NoEnvironmental factors Not within Edwards Aquifer. No action required.
NoHazardous Sites No mapped sites of concern. Recommend field investigation for any unreported sites and/or dumps.
NoArcheolgical Sites No known cultural resources conflict. Coordination with CoSA OHP needed. If work will exceed five acres or 5,000 cubic yards of earth moving, consultation with THC needed.
Geomorphology Issues Potential Ground Water May be EncounteredYes
Geotechnical issues Geology: Terrace Deposit, Rock Excavation Equipment May Not be Required, Potential Sloughing and Caving May Occur
Yes
Exist Utilities Parallel 15" sewer mainYes
YesPermit Conditions COSA for W Mayfield, railroad
Available Grade
Available Cover
Large Trees
Site Access by Combo Truck
Crosses Creek, TxDOT Rd, or Bridge
Large WTR Mains
Large Gas Mains
Easement Required (number of parcels)
0
Point Repair Identified by a ProfessionalNo
By-Pass Info
Peak Wet Weather (MGD) 1.95- From Model for Pipes > 12"- Calculated for Pipes < 12" with Mannings Assuming Full Flow
US Suction Manhole 19433
DS Discharge Manhole 92168
By-Pass Length 1170
By-Pass Pumping Information
Street Width 24
Quantity of Street Repair (LF) 399.20
Street Repair Data
30% Package Number 2
Reason Selected for 30% Concrete E
Reviewed in 10% Design Yes
Base or Additional Pipe Base Pipe
On CPMS Project No
Avg Day (MGD) 0.18- From Model for Pipes > 12"
NOT FOR CONSTRUCTION
THIS DOCUMENT IS RELEASED FOR THEPURPOSE OF INTERIM REVIEW UNDER THEAUTHORITY OF: TADEUSZ J. STAWASZ TEXAS NO:102666 ON DATE: 7/13/18IT IS NOT TO BE USED FOR CONSTRUCTION,BIDDING OR PERMINT PURPOSE.
0 394 794 1170
19433
18872
18874
19433
651.700
-10.163
18872
650.800
-10.136
18874
649.200
-9.431
92168
648.800
-9.671
19433.1
15.0
639.760
638.900
0.218
1.95
1.00
1.9456
2.660
18872.1
984923
15.0
638.900
638.660
0.060
1.02
2.00
1.9516
2.356
18874.1
24.0
638.660
637.150
0.401
9.26
0.99
4.8611
4.356
Node
ground (ft AD)
flood dep (ft)
Link
Asset ID
width (in)
us inv (ft AD)
ds inv (ft AD)
grad (%)
pfc (MGD)
CC Project Area ID
CC Alternative
surc
US flow (MGD)
US velocity (ft/s)
637.0
652.0
638.0
639.0
640.0
641.0
642.0
643.0
644.0
645.0
646.0
647.0
648.0
649.0
650.0
651.0
ft A
D
ft
P-8
SAN ANTONIO WATER SYSTEMCONDITION 30% DESIGN
PROFILE 9: COMPKEY ID 984923
LEGEND
Flow Level
2-ft ContoursManhole Rim Elevation
Ground Elevation Based on: