Upload
dinhngoc
View
215
Download
2
Embed Size (px)
Citation preview
;.. "HefnOSI.alo(System
_ .._. ::.... ;,1(2]02
/ TRANSMEDICA
Rapid Urease Test
::: positive 0,stnbuted 1n the II.S.
• @ by K•mberly-Ciua A . ,ell GA 30076
::: NegatiV8 Global Sales. LL well, GA 30076 USA ,J K•mberly-Ciar , 1 Clark Worldwlde, lnc
Trademark or Trademark of K•mber y·
0 0 ove seo MTW.
Endoskopie
Ecision
E NDOC LOT+
@nDOCUFF"
Jllntelligent IIJ Endoscopv
Juan Sánchez Azcona 1323 Col. del Valle Deleg. Benito Juárez México, D.F. C.P. 03100 Tel. 5605-9008 Fax. 5605-9103
www.transmedica.com.mx
ÍNDICE
22 - 87 MTW ENDOSKOPIE
Vía biliar 22-51
EUS 52-59
Polipectomía 60-64
Accesorios 65, 66, 68
ESD 69-75
97 - 100 OVESCO OTSC SYSTEM.
101 - 106 ENDO-CLOT+
107 - 109 KIMBERLY CLARK
110 - 113 ENDOCUFF
114 - 117 THE STANDARD
118 - 120 MICRO-TECH
121 - 122 INTELLIGENT ENDOSCOPY
123 - 124 EMCISION
125 VARIOS
126 - 128 NOTAS
Esteroscopía mono y doble balón 76-87
Estractor protesis plásticas 88-89
Dilatación 90-91
Pinzas estractoras cuerpos extraños 92-93
ESO 94-96
TRANSMEDICA, S.A. de C.V.
Qué es TRANSMÉDICA?
Empresa Con más de 10 años de experiencia en el ramo, nos hemos posicionado como una compañía altamente competitiva en la que nuestro principal interés es llevar a nuestros clientes la gama más amplia de productos especializados en endoscopía, reconocemos áreas de oportunidades y el potencial de nuevas tecnologías y materiales en equipos y accesorios
Objetivo:
Nuestro objetivo es que los productos que ofrecemos
cumplan con las características y los estándares más altos
de calidad para cubrir las necesidades de nuestros clientes.
Misión:
Nuestra misión se basa en la continua investigación del desarrollo de productos de alta calidad que se lleva a cabo alrededor de todo el mundo, con el fin de ofrecerlos a usted para cubrir las necesidades de equipos y accesorios para la endoscopía y endocirugía.
Visión:
Compromiso Social, Confianza, Innovación, Calidez Humana, Calidad y Profesionalismo
TRANSMÉDICA 2
Re
g.-
No
. 2
03
8 |
07.1
4 |
GB
contrast agent channel
3L Ball Tip Papillotome
guide wire channel
ARTICLE NUMBER 3L BALL TIP PAPILLOTOME FOR GUIDE WIRE 0.035“
Article no. Cutting length
mm
Diameter
mm
Length
cm
Special
features
PU
99 02 33 61 20 2,45-1,95 215 cm 3 Lumen 5
99 02 33 71 25 2,45-1,95 215 cm 3 Lumen 5
99 02 33 81 30 2,45-1,95 215 cm 3 Lumen 5
We reserve the right to make technical changes and to deviate from the depicted images.
MTW-Endoskopie W. Haag KG I Goldsbergstraße 18 I D-46487 Wesel
Phone +49 2803 9120-0 I Fax +49 2803 8113 I E-Mail [email protected] I www.mtw-endoskopie.com
22 TRANSMÉDICA TRANSMÉDICA 23
® Safe-Cut
Artlele-no. X Dlameter Langth (mm) (mm) (cm)
99 0282 41 30 2,3 > 1,8 215
Papillotome with partially insulated
cutting wire
More precise and effectíve cuttíng by the parlially
lnsulated cutt ng wfre. Uníntentíonal injuries olthe smallíntestíne foldin !he vicinity of the papilla are límhed
doublo·lumon for guíde wlre 0.0351nch
®o
1 MTW 1 Endoskopie
Papillotome rotatable
28 TRANSM OICA -------------- - - -- - :
TRANSM OICA 25
1
BaiiTip-papillotome with
atraumatlc tlp, optlonally wlth 0.035" pre-loaded SnapTip guidewlre
MTW Endoskopie
1 BaiiTip-Papillotome with atraumatlc tlp
• BaiiTlp,new rounded atraumatlc tip
• Ellipsoid deslgn(allows lor controlled guidance)
• ERBE plug (lncl OL adapter)
• Cutling lenglh 20 or 30 mm
® innovative • Radlopaque tip
• 0.035" SnapTip kink resistan!guide wire
• With lorm stabilizer (supports 11 o'clock
cutting dlrection)
• Single use @ • The speclal Y construction (2 fumen)
places all importan!inlets such as contrast medium, wire guide channeland the operatlon olthe papillotome directly
in your hand.
/ 1 PaplllotomeBai!Trp
Articlc-no. Diametcr Lcnglh Gutdewire CuUing length Packaglng
(Artlcle-no.003900) unit
9902 7651 2,3> 1,8mm 215cm wlth0.035" Fü rungsdraht 20mm Spleces
99027051 2,3> 1,8mm 215cm wllh0.035" Führungsdrta
1 30mm
Spleces
99023671 2,3> 1.8mm 215cm lor 0.035•Führungsdrahl 20mm
9902 30 71 2,3> l,8mm 215cm lor 0.035"Führungsdraht 30mm
Spieces Spieces
Klnk resistan! gulde wlre SnapTip
00 39 00 400cm 50 mm hydrophlllc
Mlnlmumordorquanlily
0.035' ecated."""ighl pla&um lip 2pieces
26 TRANSM OICA -------------------- -
:
TRANSM OICA 27
Guide wire SnapTip Kink resistent guide wire
Ar ticle no: 00 39 46
0.025“
460 cm
0.035“
460 cm
30 TRANSMÉDICA TRANSMÉDICA 31
Re
g.-
No
. 2
04
6 |
09.1
4 | G
B
SPECIAL BENEFITS:
Good visible radiopaque markers
• Transparent catheters for permanent monitoring of the position of the guide wire
• Suitable for 0.025” or 0.035” guide wire
• Ideal strength of the catheter for the better transfer of the feed force
• Balloon of 12 mm or 16 mm
• Extremely durable balloon
• Particularly good visible radiopaque markers
• Distal scale of the catheter
• Unique identification of each lumen
• High flow rate of contrast medium
ARTICLE NUMBER STONE-EX TRACTION-BALLOON
Article no. Ch. Description Balloon
Ø mm
Length
cm
Guide wire
inch
PU
03 26 72 32 7 > 5 3 lumen, tapered,
transparent catheter
16 200 0.035 5
03 26 72 33 7 3 lumen,
transparent catheter
16 200 0.035 5
03 20 51 20 5 2 lumen,
grey catheter
12 200 0.025 10 without
Fig.
03 20 72 36 LF 7 latexfree, 3 lumen,
grey catheter
16 200 0.035 10 without
Fig.
We reserve the right to make technical changes and to deviate from the depicted images
MTW-Endoskopie W. Haag KG I Goldsbergstraße 18 I D-46487 Wesel
Phone +49 2803 9120-0 I Fax +49 2803 8113 I E-Mail [email protected] I www.mtw-endoskopie.com
36 TRANSMÉDICA TRANSMÉDICA 33
Cytology-brush double-lumen with guiding tip
for guide wire
Threelumen
Stone-Extraction-Balloon with two radiopaque metal balloon markers
ARTICLE NUMBER CY TOLOGY-BRUSH WITH GUIDING TIP
DOUBLE LUMEN, FOR GUIDE WIRE 0.035“
Article no. Diameter
brush mm
Diameter
mm
Length
cm
PU
08 21 28 1 2,5 2,7 200 cm 2
We reserve the right to make technical changes and to deviate from the depicted images.
34 TRANSMÉDICA TRANSMÉDICA 35
1 Lithotomy baskets
EASY-CATCH
MTW Endoskopie
MANUFAKTUR
1 Controllable Biopsy-forceps, oval spoonshaped mouth, PTFE -coating, without spike
------ ------ innovative
Until goo bendable
Artlele-no. Diameter Length
(mm) (cm)
1106460210
0646 0210 5
2,6
2,6
120 for Bronchocopes
180 for Gastro- and Ouodenoscopes
This baskets are dístinguished by
excellent tension.
Easy stone catching through
automatically rotation during
expanslon.
40 TRANSM OICA ------------ --- - :
®
Innova ·o
POWER-CATCH
suitable for lithotripsy, for guide wire
MTW Endoskopie
MA NU F AKTUR
wt h vcry ht_gn exp t1s on-strength, tilllotripsy
sultable for llthotrlpsy, or gulde wire
Artfcel -no. X1Y orameter ength gui de wire Descrlption 1•
(mm) (mm) (cm) (lnch)
0316 34 32 25/40 2,9 215 0.035 -,- 0316 36 32 30{45 2,9 215 0.035 •,
0316 38 3.2 40/55 2,9 215 0.035
9903163432 2Sf40 2,9 215 0.035
99 0316 3632 30/45 2.9 215 0.035
99 0316 3832 40f55 2,9 215 0.035
very hl!jh expanston-slrength max.20 Kp lension
sullabte for lllhotrlpsy
All dlsposablo tlthotomy b11sko s ere dollvered In packaglng units.
Packagtng Unrt 2 pieC!eS with pre-assembled handle
for gulde wlre 0.0351nch reusable
+ ® dlsposable
Bile-stone-tithotriptor system
For the a.m.baskets:
(not include<l as astandard)
11the slone ts lrappedin lhe basket.and ilit is
not possible to withdraw the stone from the bile
duct. and also not from the basket. this set wlll help
you. You cut off lhe handle of the basket,take out
the scope, epply the metaltube, and connect it to the
speciaJ crushing handle.
Now you are able l o crush the stone.
Fixing
Article-no.
03 36
38 TRANSM OICA -------------- - - -- - :
Metaltube 09,8 mm
100 cmlenglh
Article-no.
03306
9903306 ® Paclulgln.a unll - 2 ploce•
TRANSM OICA 39
of·contrast medrum ---
1 very high expansion- suitable for 1 Lithotomy baskets, EASY-CATCH strenf hthotrlpsy
t]l'
au e
Lllhotomy baskets,• u«ilil
Article--no. Moasure X/Y Diomoler Length
(mm) eannula (mm) (cm)
03103504 25/40 2,6 215
03103604 30/45 2,6 215
0310 37 04 40/55 2,6 215
03103804 45/60 2,6 215
Handlawllh nozzle lO< lnjootlon
ol contrast medaum
........
® Llthotomy baskets,dl&posable
Artlcle-no. Measure XN Oiamc.tar Length F>ackaglng (mm) eonnula (mm) {cm) unft;Splec:u
99 0310 34 04 15/30 2.6 215 5
99 0310 35 04 25/40 2,6 215 5
9903103604 30/45 2.6 215 5
99 0310 37 04 40/55 2,6 215 5
Handle wllh nozzle for lnjootfon #
44 TRANSM OICA -----------------------------------------------: TRANSM OICA 41
1
"¿1¡3Stonecrusher Trans-endoscopically stone crushing in three steps
innovative
MTW Endoskopie
MAN UFAKTUR
Starter Kit 1 also individually available
,.EasJ Catch"
990J10J604 . Power catch"
990J 16 36 32 . Metal tubes", 3·parts
9903 37
lllll•SIIilc8 unlt = Zpieces unlt = 2 pieces
990JJ07
-.lt• 1piece
42 TRANSM OICA ---------- --- - - :
:------------------- TRANSM OICA 43
POC-guiding catheter for the direct endoscopy of the biliary tract
ORDER-NO. 04205120, PaCkaGING uNIT 2 PIECEs
The POC-guiding catheter, consisting of a balloon catheter with three
extensions, a disposable syringe and a needle for refilling the POC
guiding catheter, was developed for the peroral cholangioscopy
(POC).
The POC-guiding catheter is positioned through the working channel
of a duodenoscope, and the balloon is inflated through the insufflation
lumen of the catheter until the balloon anchors behind the stenosis.
after the removal of the guidewire, the extensions are cut off from
the POC-guiding catheter at the green mark with a sharp side cutter.
Now the duodenoscope can be removed.
subsequently, the guidewire and the cholangioscope
or the nasal gastroscope are advanced through respectively over the
POC guiding catheter through the papilla into the desired area of the
bile duct.
NEEDlE FOR l aTER
REFIllING OF ThE
POC-GuIDING CaThETER.
Thanks to the blocked balloon, the cholangioscope or rather the
nasal gastroscope can be advanced through the stenosis.
In case of insufficient air inflation of the balloon and already
separated extensions of the catheter, or accidental deflation, it is
possible to refill the balloon with the corresponding needle.
ThE RaDIOPaquE PlaTINuM
MaRkER aT ThE DIsTal END OF
ThE ballOON CaThETER hElPs
yOu TO FIND ThE RIGhT
POsITION.
POC-guiding catheter
ARTICLE NUMBER POC-GUIDING CATHETER
Article no. Diameter
Ch.
For guidewire
Ø inch
Length
cm
PU
04 20 51 20 5 0.025 240 2 pieces
We reserve the right to make technical changes and to deviate from the
depicted images.
48 TRANSMÉDICA TRANSMÉDICA 45
POC-guiding catheter for the direct endoscopy of the biliary tract
Illustration 1 Illustration 2
I N C I S I O N A R E A
Illustration 3 Illustration 4
46 TRANSMÉDICA TRANSMÉDICA 47
...
1
_.t'!IQ -
® 1
1
Endoscopy Ultra Sound
Aspiration-needle
MTW Endoskopie
._ ""'
Controllablc EMR·knives 101 · CUof't'&M:hM"
... ....... "02l':t11
- ,._
o.....
Disposable
. -enn11
® <D
Ttltt eontrol li Wcathelff ts
a.pecl.lllyi blt for p;&111 1fttl
havlng Klalallin tumor.
In lhls case- !he call let ls belptut 10
pen 1M atenoela ancl rN<:h u. bUo d\Kta.
t.o- p- Ot
!1 2 -l•l.l 0.25
. ....-llrof»"Q • m.o'WTIII'.....
• lfWII'OW...
-
The EUS Ultrasound Aspirallon-needle
is intended for ultrasonic fine needle
aspiratíon (FNA) of the submucosal and
extra-luminallesions ofthe gastro·
intestinaltract through the working
channel of an ultrasound endoscope.
The device is supplled sterile and
intended for single use only.
52 TRANSM OICA -------------- - - -- - :
TRANSM OICA 49
Article-no. 8.5
Length between
the flaps (cm)
Total length
(cm)
suitable for
guide wire
04 00 80 10 03 JS
04 00 80 10 05 JS
04 00 80 10 07 JS
04 00 80 10 10 JS
04 00 80 10 13 JS
3
5
7
10
13
5
7
9
12
15
Article-no. 10.0
Length between
the flaps (cm)
Total length
(cm)
suitable for
guide wire
04 01 00 10 03 JS
04 01 00 10 05 JS
04 01 00 10 07 JS
04 01 00 10 10 JS
04 01 00 10 13 JS
3
5
7
10
13
5
7
9
12
15
Article-no. 11.5
Ch.
Length between
the flaps (cm)
Total length
(cm)
suitable for
guide wire
04 01 10 10 03 JS
04 01 10 10 05 JS
04 01 10 10 07 JS
04 01 10 10 10 JS
04 01 10 10 13 JS
3
5
7
10
13
5
7
9
12
15
ORIGINAL
2
Guiding-system Jet-Set Ch 7.0, 8.5, 10, 11.5
including pre-loaded endoprosthesis, straight including pre-loaded pancreas endoprosthesis with side holes
length between the flaps length between the flaps
total length total length
Ch.
Article-no.
7.0 Ch.
Length between Total length suitable for
the flaps (cm) (cm) guide wire
04 30 70 10 03 JS 3 5
04 30 70 10 05 JS 5 7
04 30 70 10 07 JS 7 9
04 30 70 10 09 JS 9 11
including pre-loaded endoprosthesis, straight
Ch.
length between the flaps
total length
Article-no.
7.0 Ch.
Length between Total length suitable for
the flaps (cm) (cm) guide wire
04 00 70 10 03 JS 3 5
04 00 70 10 05 JS 5 7
04 00 70 10 07 JS 7 9
04 00 70 10 10 JS 10 12
04 00 70 10 13 JS 13 15
Packaging unit 2 pieces
Guide wire does not belong to the set Packaging unit 2 pieces
Guide wire does not belong to the set
50 TRANSMÉDICA TRANSMÉDICA 51
Re
g.-
No
. 2
02
9 |
07.
14 |
GB
Aspiration forceps Oval spoonshaped mouth with prominent spike
ARTICLE NUMBER
Aspiration forceps
Oval spoonshaped mouth with prominent spike
Article no. Diameter
(mm)
Diameter spike
(mm)
Length
(cm)
Special
Features
99 06 14 02 11 5 1,8 1 180
ARTICLE NUMBER
Lymph node biopsy forceps „Model Ruhrlandklinik Essen“ oval spoonshaped mouth with prominent
spike. The lymph node aspiration forceps was developed to collect samples from much larger para
bronchial lymph nodes.
Article no. Diameter
(mm)
Diameter spike
(mm)
Length
(cm)
Special
Features
99 11 06 11 02 30 1,8 1 120
We reserve the right to make technical changes and to deviate from the
depicted images.
56 TRANSMÉDICA
MTW-Endoskopie W. Haag KG I Goldsbergstraße 18 I D-46487 Wesel
Phone +49 2803 9120-0 I Fax +49 2803 8113 I E-Mail [email protected] I www.mtw-endoskopie.com
TRANSMÉDICA 53
Article no. Description Special features PU
10 70 1 Model Olympus, 2 openings, small for echo-duodenoscope 20
10 70 2 Model Olympus, 2 openings, large for echo-colonoscope 20
10 70 3 Model Pentax, 1 opening for echo-duodenoscope 20
10 70 4 Model Olympus, 1 opening for echo-duodenoscope 20
10 70 5 Model Pentax, 2 openings for echo-duodenoscope 20
10 70 6 Model Olympus series 160, 2 openings 20
10 70 7 Model Fujinon, 1 opening 20
10 70 8 Model Fujinon, 2 openings 20
10 70 9 Model Olympus, 2 openings for echo-bronchoscope 20
10 71 0 Model Pentax 3270, 2 openings for echo-duodenoscope 20
10 71 1 Model Olympus 180, 1 opening for echo-duodenoscope 20
10 71 2 Model Fujinon, radial, 2 openings 20
10 71 3 Model Fujinon, convex, 1 opening 20
Echo-hoods Balloons for echo endoscopy
Images in original size 1 2
Article no. 10 70 1
3 4 Model Olympus, 2 openings, small
Article no. 10 70 2 Ar
Model Olympus, 2 openings, large Mo
5 6
Article no. 10 70 3
Model Pentax, 1 opening
Article no. 10 70 4
Model Olympus, 1 opening
Article no. 10 70 5 7 8 Model Pentax, 2 openings
Article no. 10 70 6
Model Olympus Serie 160, 2 openings
9 10
Article no. 10 70 7
Model Fujinon, 1 opening
Article no. 10 70 8
Model Fujinon, 2 openings
11 12 Article no. 10 70 9
Model Olympus, 2 openings
Article no. 10 71 0
Model Pentax 3270, 2 openings
13
Article no. 10 71 1
Model Olympus 180, 1 opening
Article no. 10 71 2
Model Fujinon, radial, 2 openings
ARTICLE NUMBER EChO-hOODS
Article no. 10 71 3
Model Fujinon, konvex, 1 opening
1
2
3
4
5
6
7
8
9
10
11
12
13
We reserve the right to make technical changes and to deviate from the depicted images
54 TRANSMÉDICA TRANSMÉDICA 55
r diameter Total length Special features PU
(Ch.) (cm)
8,5 195 Cystostome with
pusher and short
straight endoprosthe-
sis for
n set Dr. C. Grotjahn
r diameter Total length Special features PU
(Ch.) (cm)
10 195 Catheter with pusher 2 pieces
and straight
endoprosthesis for
extension of
cyst drainage
wires
r diameter Total length Special features
(Inch) (cm)
0.035 460 Snap-Tip
Kink resistent guide wire
0.035 260 Snap-Tip
Kink resistent guide wire
04 90 10 03
Recommended guide
Article no. Oute
ARtIclE NUMBER 00 39 46
00 39 26
Re
g.-
N0
. 2
03
0| 0
7.1
4 |
GB
Article no. Oute
04 80 05 03
Cyst drainage set Dr. C. Grotjahn
Cyst drainage extensio
Article no. Oute
ARtIclE NUMBER RING kNIFE MoDEl PRoF. DR. U. WIll
Ring knife & Ring knife set Model Prof. Dr. U. Will
Article no. product description PU
04 82 10 00 Ring knife model Prof. Dr. U. Will for
guide wire 0.035“ (no illustration) Ø
1,8 mm, length 215 cm
2
ARtIclE NUMBER RING kNIFE sE t MoDEl PRoF. DR. U. WIll
Article no. product description PU
04 82 10 03 Ring knife set model Prof. Dr. U. Will
consisting of:
• Ring knife for guide wire 0.035“
Ø 1,8 mm, length 215 cm
• Pusher
Ø Ch. 10, length 165 cm
• 3-flap straight endoprosthesis
2
We reserve the right to make technical changes and to deviate from the depicted images.
60 TRANSMÉDICA TRANSMÉDICA 57
Article no. Outer diameter
(Ch.)
Total length
(cm)
Special features PU
04 80 05 03 8,5 195 Cystostome with
pusher and short
straight endoprosthe-
sis for transduodenal
cyst drainage
2 pieces
04 80 08 03 8,5 195 Cystostome with
pusher and straight
endoprosthesis
for cyst drainage
2 pieces
04 80 10 03 10 195 Cystostome with
pusher and straight
endoprosthesis
for cyst drainage
2 pieces
Article no. Outer diameter
(Ch.)
Total length
(cm)
Special features PU
04 90 10 03 10 195 Catheter with pusher
and straight
endoprosthesis for
extension of
cyst drainage
2 pieces
Article no. Outer diameter
(Inch)
Total length
(cm)
Special features
00 39 46 0.035 460 Snap-Tip
Kink resistent guide wire
00 39 26 0.035 260 Snap-Tip
Kink resistent guide wire
Re
g.-
N0
. 2
03
0| 0
7.1
4 |
GB
Cold snare
combination of
cold snaring and emergency coagulation
ARTICLE NUMBER
Cyst drainage set Dr. C. Grotjahn
HF connection
Cyst drainage extension set Dr. C. Grotjahn
Combination of cold snaring and emergency coagulation • cold snaring without Hf currency of polyps Ø 3-8 mm
• hot snaring of polyps Ø 8-15 mm
Recommended guide wires
ARTICLE NUMBER COLD SNARES
A HF connection is available for emergency coagulation
Article no. Opening width
mm
Diameter
mm
Length
cm
Special
features
PU
99 05 21 11 20 2 10 2,3 230 twisted 10
99 05 21 11 20 5 10 2,3 230 monofil 10
We reserve the right to make technical changes and to deviate from the
depicted images.
We reserve the right to make technical changes and to deviate from the depicted images
MTW-Endoskopie W. Haag KG I Goldsbergstraße 18 I D-46487 Wesel
Phone +49 2803 9120-0 I Fax +49 2803 8113 I E-Mail [email protected] I www.mtw-endoskopie.com
58 TRANSMÉDICA TRANSMÉDICA 59
Cyst drainage set
The cyst drainage set consists of a cystostome with an extended pusher and a 2-flap endoprosthesis.
The cyst drainage set was developed for the endoscopic puncture with HF-current. The endoprosthesis
for cyst drainage can be positioned without changing the instruments.
Removable connections
The puncture wire can be removed and replaced by a guide wire
(0.035 inches).
The prosthesis is pushed
for ward with the pusher.
Skorpio-Snare
Polypectomy snare
monofil wire with injection-needle
Figure 1 Figure 2
Figure 7
64 TRANSMÉDICA TRANSMÉDICA 61
Article no. Diameter
mm
Length
cm
Opening width
x y in mm PU
99 05 20 11 21 6 2,3 230 X = 15 / Y = 35 5
99 05 20 11 22 6 2,3 230 X = 20 / Y = 40 5
99 05 20 11 23 6 2,3 230 X = 30 / Y = 60 5
Article no. Description Diameter
Ø mm
Length
cm
PU
99 05 20 11 23 8 controllable opening width 2,6 230 2
Re
g.-
No 2
04
5 | 0
8.1
4 |
GB
Re
g.-
No
. 2
03
3 | 0
7.1
4 | G
B
Kudo Snare controllable opening width,
Polypectomy snare suitable
for mucosectomy
y
max. 45 mm
x
Mucosa resection snare
Model „EVK“ Düsseldorf
Symmetrical flat feather snare
• monofil flat wire for stabilization in the rear area
• twisted wire in the front cutting area
ARTICLE NUMBER SYMMETRICAL FLAT FEATHER SNARE
ARTICLE NUMBER KUDo sNARE
We reserve the right to make technical changes and to deviate from the depicted images.
We reserve the right to make technical changes and to deviate from the depicted images.
MTW-Endoskopie W. Haag KG I Goldsbergstraße 18 I D-46487 Wesel
Phone +49 2803 9120-0 I Fax +49 2803 8113 I E-Mail [email protected] I www.mtw-endoskopie.com
MTW-Endoskopie W. Haag KG I Goldsbergstraße 18 I D-46487 Wesel
Phone +49 2803 9120-0 I Fax +49 2803 8113 I E-Mail [email protected] I www.mtw-endoskopie.com
62 TRANSMÉDICA TRANSMÉDICA 63
HF-connection
the injection needle is
pushed back and forth.
ARtIclE NuMBER skoRPIo-sNARE
Polypectomy snare, oval, monofil wire, injection-needle included
cannulas up to 0,7 mm, needle exit 6 mm
Article no. opening width
x y in mm
Diameter
mm
length
cm
Pu
99 05 21 11 22 5 X = 20 / Y = 40 2,6 230 5
We reserve the right to make technical changes and to deviate from the
depicted images.
68 TRANSMÉDICA TRANSMÉDICA 65
Special snares
2 y
Polypectomy snare with injection-needles, X
monofil wire
Article-no. Diameter
(mm)
x
Length
(cm)
Opening-
width X/Y
(mm)
99 05 21 11 22 5 2,6 230 20 / 40 Y
Packaging unit = 5 pieces
monofil wire
Handel with nozzle to move the needle
ARTICLE NUMBER POLYP-CATCHER
Article no. Opening width
x y in mm
Diameter
mm
Length
cm
PU
99 07 30 23 0 X = 30 / Y = 60 2,3 230 10
99 07 40 23 0 X = 40 / Y = 75 2,3 230 10
We reserve the right to make technical changes and to deviate from the depicted images.
MTW-Endoskopie W. Haag KG I Goldsbergstraße 18 I D-46487 Wesel
Phone +49 2803 9120-0 I Fax +49 2803 8113 I E-Mail [email protected] I www.mtw-endoskopie.com
66 TRANSMÉDICA TRANSMÉDICA 67
® 1 1
Bite Block
MTW Endoskopie
MANUFAKTv
Cleaning-brushes, disposable MTW
Endoskopie
• Prevents bite-through and protects your device or instrument
• Attached strap holds mouthpiece in place
REF 10 01 77 3
Packaging unit = 100 pieces
72 TRANSM OICA ; ---------------- TRANSM OICA 69
Cleanlng-brushes, dlsposable ® Cleaning-brushes
Article-no. O·Brush O·IUbe Lenglh
0843050 3mm 1,6mm 100cm
0843150 3mm 1,6mm 180cm
0843250 3mm 1,6mm 230cm
085 1o51 5mm t.Bmm 180cm
'ltn ·•30 cm
280cm
Bite Block
MTW Endoskopie
M · ' F -
All disposable cleamng-brushes are
delivered In packagíng uníts.
Packaglng unlt = 50 plecas
Double-cleanlng-brushes
Article·n 0-Brush 0-tube Length
0843152 3mm 1,6mm 180cm
08 43 25 2 3mm 230cm
08 4 15 2 5mm 180 cm
08 4S 25 2 5mm
0843352 3mm
All disposable cleamng-brushes are
deliveredin packag•ng umts.
Packaglng unll =50 plecas
Disposable
f¡& 70 TRANSM DICI\ ---- -- - - - --------
-
: - - ----- - - - - --
--- TRANSM DICI\ 71
Biopsy valve for Olympus, Funjinon and Pentax endoscopes
order number unit
10 90 1 for Olympus and Funjinon endoscopes 50
10 90 2 for Pentax endoscopes * 50
Polyp Trap
order number unit
10 01 71 3 1
Polyp Trap*
order number unit
10 01 71 4 10
76 TRANSMÉDICA TRANSMÉDICA 73
Mouthguard for
children
Oxyguard D
Mouthguard
Mouthguard, disposable
with headstrap
order number description unit
10 01 76 0 Mouthguard orange, without
headstrap **
1
10 01 76 2 Mouthguard pink, for children
with headstrap
1
10 01 76 5 Oxyguard D Mouthguard for
oxygene insufflation, grey-blue,
without headstrap
10
10 01 76 7 Mouthguard blue, latex free with
blue headstrap **
1
10 01 77 3 Mouthguard, disposable with
headstrap
100
10 01 77 5 Textile-rubber headstrap, only 100
74 TRANSMÉDICA TRANSMÉDICA 75
2
Symmetrical polypectomy snares, X
twisted wire
Article-no. Diameter Length Opening-
(mm) (cm) width X/Y
(mm)
99 05 40 11 12 2 1,8 250 20 / 40
99 05 40 11 13 2 1,8 250 30 / 55
99 05 20 11 20 2 2,3 230 10 / 20 Y
99 05 20 11 21 2 2,3 230 20 / 40
99 05 20 11 23 2 2,3 230 30 / 55
99 05 40 11 21 2 2,3 250 20 / 40
99 05 40 11 23 2 2,3 250 30 / 55
Packaging unit = 5 pieces twisted wire
Symmetrical polypectomy snares, X
monofil wire
Article-no. Diameter Length Opening-
(mm) (cm) width X/Y
(mm)
99 05 20 11 22 5 2,3 230 15 / 30 monofil wire
Y 99 05 20 11 23 5 2,3 230 25 / 50
Handle
99 05 40 11 23 5 2,3 250 25 / 50
Packaging unit = 5 pieces monofil wire
Handle
1
Polypectomy snares
Symmetrical polypectomy snares, X
twisted wire
Article-no. Diameter
(mm)
Length
(cm)
Opening-
width X/Y
(mm)
99 05 40 11 12 2 1,8 250 20 / 40
99 05 40 11 13 2 1,8 250 30 / 55
99 05 20 11 20 2 2,3 230 10 / 20 Y
99 05 20 11 21 2 2,3 230 20 / 40
99 05 20 11 23 2 2,3 230 30 / 55
99 05 40 11 21 2 2,3 250 20 / 40
99 05 40 11 23 2 2,3 250 30 / 55
Packaging unit = 5 pieces twisted wire
Symmetrical polypectomy snares, X
monofil wire
Article-no. Diameter
(mm)
Length
(cm)
Opening-
width X/Y
(mm)
99 05 20 11 22 5 2,3 230 15 / 30
Y 99 05 20 11 23 5 2,3 230 25 / 50
99 05 40 11 23 5 2,3 250 25 / 50
Packaging unit = 5 pieces monofil wire
Asymmetrical polypectomy snares,
twisted wire
Article-no. Diameter
(mm)
Length
(cm)
Opening X
width (mm)
99 05 20 11 21 1 2,3 230 15
X
99 05 20 11 22 1 2,3 230 25
Packaging unit = 5 pieces twisted wire
80 TRANSMÉDICA TRANSMÉDICA 77
Otameter
Leoglh lltDtb fi
Opemng-
Art cle-no. Ofameter l.ength Openlng-
(mm) (cm) wldlh (mm) (cm) wldth
(Xm; m) (X= mm)
1,8 250 20130
2,3 250 20/30
2,3 250 30/45
Diametcr l..ength
Openlng· (mm) (cm) Wldth
(X= mm)
Spraycatheter
Articte-no. Olemeter
(mm)
Length (cm)
..
1 Foreign-body removing forceps,
r<'usb e
MTW Endoskopie
lithotomy and foreign body baskets,
disposable MTW 1
Endoskopie
Foreign·body removing forceps,3-arms, metal spring
Article-no.
130710120 1,8 250 30
Llthotomy and foreign body baskets, twi sted wires
®
99 13 0311 24 • 9913031134
9913031136
Packaging unit:5 pieces
Polypotome.3-arms, metal spring
( "-_
.
Art cle-no.
13 0720 22 o 2.2 250 30
tilidiñif·
Spraycatheter,
reusa;)le
13 01 01 21 o 1,8 250
13 01 01 31 o 2,3 250
-·: f '
m!
78 TRANSM OICA ------------------- : TRANSM OICA 79
Article-no. Olameter Length (X= mm) Desc:riptlon
(mm) (cm)
Article-no. Ofameter Length (mm) (cm) (X" mm} Deserlptton
®
1 Papillotomes,
disposable
MTW. Endoskopie
Sclerosing-needles,
disposable MTW. 1
Endoskopie
Papillotome, flliform
Sclerosing-needles, click-lock-system,
disposable
Article-no. Dlamntar (mm)
Lenglh (cm)
(X" mm) ® Artlcle-no.
Dlamettlf Length CannuJa O.scrlptlon
(mm) (cm) (onm)
Type
991302 00 51 1,6 250 30 0910728111 0910728212
1.8 2,2
280 280
0.7 O,7 wilh metaltip
•a• "b"
Papillotome, flli form, for guide wlre 0.035 inch ®
Packaglng unll:10 pfeees
9913023051 2,3> 1,8 250 30 ,.,
Papillotome B-11-stomach ®
991302 3161 2,3 250 15 1.,_
Needle-papillotome. lnjectíon through the cannula ® Article-no. Dlameter Length
(mm) (cm) (X= mm)
9913020111 2,3 250 6
•
84 TRANSM OICA -------------- - - -- - :
TRANSM OICA 81
2
Symmetrical polypectomy snares, X
twisted wire
Article-no. Diameter Length Opening-
(mm) (cm) width X/Y
(mm)
99 05 40 11 12 2 1,8 250 20 / 40
99 05 40 11 13 2 1,8 250 30 / 55
99 05 20 11 20 2 2,3 230 10 / 20 Y
99 05 20 11 21 2 2,3 230 20 / 40
99 05 20 11 23 2 2,3 230 30 / 55
99 05 40 11 21 2 2,3 250 20 / 40
99 05 40 11 23 2 2,3 250 30 / 55
Packaging unit = 5 pieces twisted wire
Symmetrical polypectomy snares, X
monofil wire
Article-no. Diameter Length Opening-
(mm) (cm) width X/Y
(mm)
99 05 20 11 22 5 2,3 230 15 / 30
Y 99 05 20 11 23 5 2,3 230 25 / 50
Handle 99 05 40 11 23 5 2,3 250 25 / 50
Packaging unit = 5 pieces monofil wire
Handle
twisted wire
1
Polypectomy snares
Symmetrical polypectomy snares,
X
monofil wire, rotatable
Article-no. Diameter
(mm)
Length
(cm)
Opening-
width X/Y
(mm)
99 05 20 21 22 5 2,3 230 17 / 32
Y 99 05 20 21 23 5 2,3 230 25 / 50
Packaging unit = 5 pieces monofil wire
Symmetrical polypectomy snares, X
twisted wire
Article-no. Diameter
(mm)
Length
(cm)
Opening-
width X/Y
(mm)
99 05 20 12 20 2 ES 2,3 230 15 / 30
Packaging unit = 50 pieces Y
99 05 20 12 23 2 2,3 230 30 / 55
Packaging unit = 10 pieces
99 05 20 12 23 2 ES 2,3 230 30 / 55
Packaging unit = 50 pieces
twisted wire
Symmetrical polypectomy snares, hexagonal X
twisted wire
Article-no. Diameter
(mm)
Length
(cm)
Opening-
width X/Y
(mm)
99 05 20 12 23 4 ES 2,3 230 30 / 55
Packaging unit = 50 pieces
Y
99 05 20 12 23 4 2,3 230 30 / 55
Packaging unit = 10 pieces
twisted wire
82 TRANSMÉDICA
Handle TRANSMÉDICA 83
GPAK Bile duct prosthesis application catheter
and endoprosthesis extraction catheter
88 TRANSMÉDICA TRANSMÉDICA 85
on
markers
------
®
1 Guiding-systems. disposable
Jet-Set
MTW Endoskopie
New threelumen stone-extracti
balloon, with 2 opaque metal balloon MTW 1
' Endoskopie
Guiding-system consisting of:
Guiding catheter with 3 platinum rings
and Pusher
Bestei Nr.
Gu•dlng catheter
Pusher
forendo- for gulde wlre Color Paelceglng
O 1 Lengll'l O 1 Lengt prostheses unll (CI'.I ) / (cm) (Ch.) 1 (em) Ch.
0413818 5 1 250 8,5 1 220 8.5 l""i wl'liel 5 pieees
Guide wire
reusable
Klnk resistan!guide wire
NITINOL•
Artlcle-no. Charr. o mm
Lenglh Guido wlm (cm) (lnch)
Article-no. Oiamler (lneh)
Length Oescnpllon
(cm)
13 0326 72 33
Packaglng unll :2 pieces
7 16 250 0.035 lhreelumen
00 22 55 0.025 550 groen·black
86 TRANSM OICA ------------------- - : TRANSM OICA 87
Article no. Length be-
tween the
flaps (cm)
Total
length
(cm)
Diame-
ter
(Ch.)
Diame-
ter
(Ch.)
Length
(cm)
for guide wire
Ø inch
04 20 80 10 03 G 3 5 8,5 8,5 220 0.035
04 20 80 10 05 G 5 7 8,5 8,5 220 0.035
04 20 80 10 07 G 7 9 8,5 8,5 220 0.035
04 20 80 10 10 G 10 12 8,5 8,5 220 0.035
04 20 80 10 13 G 13 15 8,5 8,5 220 0.035
04 20 80 10 15 G 15 17 8,5 8,5 220 0.035
04 21 00 10 03 G 3 5 10 10 220 0.035
04 21 00 10 05 G 5 7 10 10 220 0.035
04 21 00 10 07 G 7 9 10 10 220 0.035
04 21 00 10 10 G 10 12 10 10 220 0.035
04 21 00 10 13 G 13 15 10 10 220 0.035
04 21 00 10 15 G 15 17 10 10 220 0.035
Article no. Diameter
(Ch.)
Length
(cm)
04 12 81 8 8,5 220 for endoprostheses Ch. 8,5
04 12 81 9 10 220 for endoprostheses Ch. 10
Reg
.-N
o.
20
31 |
07.1
4 |
GB
ARTICLE NUMBER GPAK WITH ONE ENDOPROSTHESIS
Packaging unit: 2 pieces
Size of the endoprosthesis Size of the prosthesis system
Foreign body removing-forceps short alligator mouth, 1 to 2 teeth,
long alligator mouth 1 to 2 teeth
ADDITIONALLY AVAIL ABLE ENDOPROSTHESES FOR THE GPAK-ENDOPROSTHESIS-SET
Endoprosthesis straight, dark gray, PTFE, with platinum ring.
Please select an order number from the table above for additional endoprostheses.
The „G“ at the end of order number is omitted.
Total length
Length between the flaps
Ø 8,5 Ch. or Ø 10 Ch.
ARTICLE NUMBER FOREIGN BODY REMOVING-FORCEPS ARTICLE NUMBER ENDOPROSTHESIS EXTRACTION CATHETER
Packaging unit = 2 pieces
Article no. Description Diameter
mm
Length
cm
PU
99 07 21 32 0 short alligator mouth, 1 to 2 teeth 2,3 230 100
99 07 21 42 0 long alligator mouth, 1 to 2 teeth 2,3 230 100
We reserve the right to make technical changes and to deviate from the depicted images.
MTW-Endoskopie W. Haag KG I Goldsbergstraße 18 I D-46487 Wesel
Phone +49 2803 9120-0 I Fax +49 2803 8113 I E-Mail [email protected] I www.mtw-endoskopie.com
92 TRANSMÉDICA TRANSMÉDICA 89
Re
g.-
No.
20
39 | 0
7.1
4 | G
B
Dilatation balloons
Inflator
Dilatation balloons • TTS – dilatation balloon (achalasia excluded)
• for guide wire 0,035“
• high pressure build-up
• different versions
• easy handling
• ergonomic form
• advanced safety standards
ARTICLE NUMBER DIL ATATION BALLOON
Article no. Catheter (mm) Balloon (mm) Pressure (ATM) Working channel
Length ø Length ø Recommen-
ded
Maximum
permitted ø
12 06 40 250 2500 2,4 40 6 8 13 2,8
12 08 40 250 2500 2,4 40 8 8 13 2,8
12 10 40 250 2500 2,4 40 10 8 13 2,8
12 12 60 250 2500 2,4 60 12 6 10 2,8
12 14 60 250 2500 2,4 60 14 5 9 2,8
12 18 80 250 2500 2,4 80 18 4 8 2,8
12 20 80 250 2500 2,4 80 20 4 7 2,8
ARTICLE NUMBER ACHAL ASIA BALLOON
Article no. Catheter (mm) Balloon (mm) Pressure (ATM) Length ø Length ø Recommen-
ded
Maximum
permitted
12 30 80 90 900 3,5 80 30 2,5 4 Use outside the
endoscope 12 35 80 90 900 3,5 80 35 2,5 4
ARTICLE NUMBER INFL ATIONS-INSTRUMENT
Article no. Capacity (cc) Pressure (ATM) Connection
12 30 3 30 30 3-way-valve
We reserve the right to make technical changes and to deviate from the depicted images.
MTW-Endoskopie W. Haag KG I Goldsbergstraße 18 I D-46487 Wesel
Phone +49 2803 9120-0 I Fax +49 2803 8113 I E-Mail [email protected] I www.mtw-endoskopie.com
90 TRANSMÉDICA TRANSMÉDICA 91
Article no. Description Diameter
mm
Length
cm
PU
99 07 23 12 3 3 arms
PTFE-Mantel
2,3 230 100
2 mm
X
1,4 mm
2 further ESD-/EMR-Knives from
®
Endoskopie
ESD-knife, insulated Sapphire ball tip, model "b"
Ø 2,3 mm
Article-no.
X
(mm)
Diameter
(mm)
Electrode
Ø (mm)
X
Length
(cm)
99 02 02 71 5 2,3 0,4 185
• variable setting of cutting length • minimal invasion into deeper tissue
• minimal risk of perforation b
Hook-knife, model "c"
Article-no. X
(mm)
Diameter
(mm)
Electrode
Ø (mm)
Length
(cm)
99 02 02 81 5 2,6 0,4 185
• incision and dissection longitudinal and lateral direction • cutting and raising of mucusa in pulling technique
c
Triangle-knife, model "d"
Article-no.
X
(mm)
Diameter
ca. (mm)
Electrode
Ø (mm)
Length
(cm) X
Polypotome 99 02 02 91 5 2,6 0,4 185
• marking, incision and dissection • cut in any direction • hemostasis of smaller bleeding d
UNI-knife (universal-knife), model "f"
Foreign body
removing forceps
PTFE-tube
Article-no.
X
(mm)
Diameter
ca. (mm)
Wire
Ø (mm)
Length
(cm) X
PTFE-tube
99 02 05 11 variabel 2,3 > 1,8 0,3 185 • cut in any direction • variable cutting length for marking, incision and dissection • perforation protection at the end of the tube
• flexibility reduces mechanical perforation f
ESD-knife, insulated Sapphire tip with triangle,
model "g"
Detail „A“
Cutting
Saphir-
Ø 2,3 mm
ARTICLE NUMBER FOREIGN BODY REMOVING FORCEPS
Article-no. X
(mm)
Diameter
(mm) Electrode
Ø (mm)
Length
(cm) knife tip
X
Detail „A“
99 02 22 91 5 2,3 0,4 185
• for simple white area dissection • variable setting of cutting length • minimal invasion into deeper tissue • minimal risk of perforation
g Triangle knife
ARTICLE NUMBER POLYPOTOME
Article no. Description Diameter
mm
Length PU
cm
99 07 23 22 3 3 arms
PTFE-tube
99 07 24 22 3 4 arms
PTFE-tube (no illustration)
2,3 230 100
2,3 230 100
96 TRANSMÉDICA TRANSMÉDICA 93
-Set ®
Endoskopie "Endoscopic Submucosa-Dissection"
-Set
"Endoscopic Submucosa-Dissection"
®
2
-Set "Endoscopic Submucosa-Dissection"
Needle-knife, model "a"
X Article-no. X
(mm)
Diameter
(mm) Electrode
Ø (mm)
Length
(cm)
99 02 02 11 6 1,6 0,3 185
Needle tip
• incision and dissection
Injection-needle, with distal guide ring
X
Article-no.
X
(mm)
Diameter
(mm)
Needle
Ø (mm)
Length
(cm)
09 10 71 82 12 5 2,35 0,7 180
• for local injection and tissue lifting
Ø 2,3 mm ESD-knife, insulated Sapphire tip, model "e"
Article-no. X Diameter Electrode Length
(mm) X
ca. (mm) Ø (mm) (cm)
99 02 22 81 5 2,3 0,4 185
• best setting of cutting length
• minimal invasion into deeper tissue
• minimal risk of perforation
• able to lift tissue
Grasping-forceps X
Article-no. X
(mm)
Diameter
(mm)
Length
(cm)
07 21 24 0 10 2,6 185
• for atraumatical removal of tissue by maintaining
the tissue border line
ESD-set 8 99 02 01 0 consisting of:
1x Needle-knife 99 02 02 11
1x Injection-needle 09 10 71 82 12
1x ESD-knife, insulated Saphir tip 99 02 22 81
1x Grasping-forceps 07 21 24 0
Substitute-ESD-set 8 99 02 01 1 consisting of:
1x Needle-knife 99 02 02 11
1x Injection-needle 09 10 71 82 12
1x ESD-knife, insulated Saphir tip 99 02 22 81
Technical changes and picture deviations are reserved
94 TRANSMÉDICA TRANSMÉDICA 95
Detalles y componentes
OTSC® System Está formado por un capuchón de aplicación con un clip incorporado, hilo y una manija para la liberación del clip.
El capuchón se coloca en la punta del endoscopio. El clip se acciona apretando el hilo con la manija de lib-
eración. El sistema es muy flexible, por lo que es usado para múltiples indicaciones y en todos los equipos
convencionales de endoscopia. Los diversos clips y capuchones pueden clasificarse de la siguiente manera:
Carac terísticas y tamaños del capuchón de aplicación :
• Tres diferentes tamaños de capuchones adaptables para casi todos los endoscopios comerciales
(tamaños 11, 12, 14)
• Dos diferentes profundidades del capuchón para agarrar menos o más tejido durante la aproximación
(3 y 6 mm)
• Carac terísticas de los clips :
• Tres diferentes tamaños adaptados al tamaño del capuchón ( tamaños 11, 12, 14)
• Tres diferentes formas de dientes adecuado para diferentes indicaciones y tejidos ( tipos a, t, gc)
Versiones del OTSC® : type a type t type gc
Diámetro del endoscopio Ø 8.5 – 11 mm Ø 10.5 – 12 mm Ø 11.5 – 14 mm Over-The-Scope Clipping system para endoscopia flexible Profundidad
del capuchón
3 mm 6 mm
OTSC® Reloader
El Recargador es usado para recargar un segundo clip en un OTSC® System ya montado si fuera necesario en la
misma sesión. El OTSC® Reloader no se incluye en el OTSC® System y debe ser ordenado separadamente.
Está disponible con clips de todos los tamaños y versiones.
Accesorios de aplicación del OTSC®
Dos instrumentos están disponibles para facilitar el uso del OTSC® System.
Para una mejor aproximación del tejido especial-
mente cuando está endurecido (ej. fístulas, úlceras
crónicas). Shaft flexible, longitud 165 cm y 220 cm.
OTSC® Anchor 220 tt, especial para tejido delgado.
Para una fácil aproximación de los bordes
de la lesión (ej. perforación).
Shaft flexible, longitud 165 cm y 220 cm.
100 TRANSMÉDICA TRANSMÉDICA 97
El nuevo OTSC® System es sinónimo de eficacia en endoscopia flexible para
• Sangrado agudo
• Cierre de todo el espesor de la pared
• Compresión y aproximación del tejido
• Manejo de complicaciones luego de endoscopias o intervenciones quirúrgicas
OTSC ® O ver-The-Scope Clipping para endoscopia f lexible
Type a
Type t
Type gc
El OTSC® System es un nuevo sistema de clipado para
ser aplicado por vía endoscópica. Ofrece al médico
tres características únicas comparadas
con otros sistemas:
• Mayor volumen de tejido asegurado
• Mayor estabilidad del sitio de la lesión
• Estiramiento mínimo del tejido circundante
Las excepcionales características y las funciones tera-
péuticas del sistema están basados en su material
único y en el diseño: El Nitinol superelástico es bio-
compatible y de ser necesario el clip puede ser aplica-
do como un implante a largo plazo.
El uso del OTSC® System es intuitivo y fácil, muy simi-
lar a otros dispositivos que usan capuchones. Es
compatible con todos los endoscopios comerciales.
Una variedad de tamaños y tipos están disponibles.
Todos los productos OTSC® son descartables y
diseñados para el uso en un solo paciente.
Además para un cierre fácil y preciso de lesiones
grandes, se disponen de accesorios de aplicación
del OTSC: OTSC® Twin Grasper y el OTSC® Anchor
ayudan a aproximar el tejido para el tratamiento
de perforaciones, fístulas, etc.
Aplicación
Hemostasia Cierre de paredes
Visualización de la lesión
(Si es necesario usar los accesori-
os de aplicación del OTSC®)
… aproximación del
capuchón al tejido …
… aplicación del clip con la
manija de liberación …
… procedimiento
completado.
Visualización de la lesión
(Si es necesario usar los accesorios
de aplicación del OTSC®) …
… aproximación del
capuchón al tejido …
… aplicación del clip con la
manija de liberación …
… procedimiento
completado.
Ejemplo: Detener la hemorragia post polipec tomía
Más ejemplo: Úlcera péptica sangrante
Ejemplo: Cierre de fístula en el colon
Más ejemplos: Perforaciones, fugas anostomóticas, otras complicaciones post operatorias
Indicaciones adicionales Marcado endoscópico, cierre de órganos en el tracto gastrointestinal despues de interveniónes NOTES (Natural Orifice Transluminal Endoscopic Surgery)
98 TRANSMÉDICA TRANSMÉDICA 99
Application System
EPI provides an innovative powder delivery system to enable endoscopists to spray the powder- G I
format agent directly to the designated site via endoscope. The innovative applicator includes a
delivery catheter and a specially designed powder/gas mixing chamber that is connected to the
powder container and an external gas source.
The delivery catheter is inserted into the endoscope and positioned towards the lesion in the gastro-
intestinal tract. Pressure coming from the gas compressor propels the powder through the catheter
directly to the designated area. The unique anti-reflux design prevents occlusion.
Technology Advantages
+ Directly spray the powder to the designated area
+ Works for both gastroscopy and colonoscopy
+ Easy to deploy
NEW TOPICAL THERAPEUTIC SOLUTIONS
FOr GASTROINTESTINAL ENDOSCOPy
104 TRANSMÉDICA TRANSMÉDICA 101
Technologies
Polymer Solution for hemostasis
AMP® technology is a proprietary engineering process that modifies plant starch into biocompatible,
absorbable hemostatic polysaccharides.
AMP® particles have a molecular structure that rapidly absorbs water from blood, causing a high
concentration of platelets, red blood cells and coagulation proteins at the bleeding site which accel-
erates the physiologic clotting cascade. The interaction of AMP® particles with blood rapidly
produces a gelled matrix that adheres to and seals the bleeding tissue. AMP® particles are readily
dissolved by saline irrigation and are degraded rapidly by human enzymes.
AMP® particles have been widely used in open surgery and proved to be safe and effective in
achieving hemostasis.
+ Efficacy
+ Safety
+ Ease of Use
102 TRANSMÉDICA TRANSMÉDICA 103
102 TRANSMÉDICA
Agentes de diagnóstico y consumibles
Clotest (prueba de detección para helicobacter pylori).
Product
EndoClot® Polysaccharide Hemostatic
System (EndoClot® PHS)
EndoClot® PHS consists of Absorbable Modified Polymers (AMP®) and a powder delivery system. It
is intended for use as an adjunct hemostat to control bleeding from capillary, venous or arteriolar
vessels in the upper and lower GIT.
Powder
AMP® particles are biocompatible, non-pyrogenic and starch
derived. AMP® particles contain no human or animal com-
ponents.
+ Adhesive
+ Ultra hydrophilic
+ Fast degradation
Applicator
The applicator is composed of a powder/gas mixing chamber,
a delivery catheter and connecting tube with a gas filter to
external gas source.
+ Easy to control
+ Anti-reflux design to prevent occlusion
+ Effective for use in hard to reach areas
air source
EndoClot® Air Compressor is the recommended gas source
for the powder delivery system.
H (Anti-reflux gear):
Air Pressure at 18 ± 3 kPa
L (Powder spraying gear):
Air Pressure at 12 ± 3 kPa
108 TRANSMÉDICA TRANSMÉDICA 105
100 TRANSMÉDICA TRANSMÉDICA 101
Hemostatic solution in upper and
lower GIT to control bleedings
EndoClot® PHS is safe and effective for controlling bleeding in GIT. It works particularly well for
large and oozing wounds. Additionally, it allows endoscopists to control bleeding when conventional
hemostatic techniques are impractical to apply. EndoClot™ PHS can be used to prevent re-bleeding
after endoscopic, invasive surgery.
Indications for use:
+ Peptic ulcer bleeding
+ Bleeding from minimally invasive surgery
+ Biopsy
+ Polypectomy
+ EMR
+ ESD
Application techniques
+ Remove excess blood
+ Spray a liberal amount of AMP® particles on the wound site
+ Hold the dispenser and gas/powder chamber in an upright position to
avoid spillage when inserting catheter into endoscope
+ Avoid direct contact of catheter tip with any fluid to prevent blockage
+ Avoid folding catheter
+ Apply quickly, deflation is required when EndoClot™ PHS is used
in GIT for over more than one minute
A B C D E
A EMR was applied to remove the colon adenoma
B AMP® particles were applied to control heavy postoperative bleeding
C A gel-like barrier formed to ”seal” the bleeding wound
D 48 hour reexamination – clean wound
E 1 month reexamination – wound healed completely
106 TRANSMÉDICA TRANSMÉDICA 107
TRANSMÉDICA 103 106 TRANSMÉDICA
Agentes de diagnóstico y consumibles
Pytest (prueba de aliento).
Consumibles para Pytest
• Air pump - Bomba de aire
• Líquido colector. 1000ml
• Collection vials (viales)
• Dispensador
• Dispensador RDSF
• Líquido de centelleo. Galón 4 lts
• Set estándar (set de calibración).
• Máquina Pytest
112 TRANSMÉDICA TRANSMÉDICA 109
1
1 proving
visualisation
and tip control
during
co onoscopy.
110 TRANSMÉDICA
Designed to:
•Enhance visualisation of colonic mucosa
•lmprove tip control during extubation
•Help clinicians perform EMR on difficult
lesions.
The Endocuff is disposable and simply slides over the tip of the colonoscope distal to the bending section. lt does not interfere with normal colonoscope function. Each individual flexible arm is hinged at its base so that during anal intubation and forward motion they automatically retract into the EndoCuff casing to create a smooth low friction surface. The Endocuff takes colonoscopy to a new level of detection with its innovative, intuitive and easy to use approach. The Endocuff gently opens the colon for easy inspection, its unique array of flexible arms maintains the tip of the instrument in the centre of the lumen and retracts the mucosal folds to allow dynamic inspection as they move back into their resting position. Endocuff provides better tip control so that the endoscopist is able to withdraw without sudden slippage. The flexures can be inspected in greater detail and concertinaed tracts of sigmoid colon are opened as the arms gently separate the folds to provide a clear view of the mucosa behind them. Maintaining tip position during EMR and polypectomy is essential to ensure the procedure is performed safely and quickly. The Endocuff acts as a handbrake allowing optimization of tip position during therapy and retrieval and helps to prevent movement as instruments are fed through the biopsy channel. Endocuff brings better tip control and vision to colonoscopy.
@noocupp·
1 lmproved
lip control
The advantages of Endocuff assisted colonoscopy:
•There is no interference of vision even when using the latest 170 degree colonoscopes.
•The mucosal folds are retracted automatically during colonoscope withdrawal, enabling their upstream surface and the mucosa between the folds to be viewed.
•The movement of the folds provides a dynamic picture so even the smallest of polyps can be identified by the play of light across the mucosal surface.
•Fold retraction begins before de fold is viewed so there is no need to keep re-intubating to manipulate folds that are beyond the tip.
•Larger folds, folds ata flexure or those in a wider part of the colon can be manipulated with ease.
•The Endocuff centres the colonoscope in the middle of the lumen preventing sudden slip back and annoying "red-out".
•The protrusions can be used to manipulate mucosal lesions and the environment around them during EMR. Lesions that are difficult to access and those hidden behind folds are now accessible for treatment.
Endocuff enhances the endoscope
without impeding its flexibility
TRANSMÉDICA 111
1
C€
1
THE STANDARD
lntend use
Black Eye is indicated for endoscopically marking lesions in the Gl tract when the
endoscopist anticipates the lesion will require surgical removal within 30 days.
Technological Characteristics and Substantial Equivalence
Black Eye is substantially equivalent to the predicate colon marker. The Black Eye and the predicate
device have same indications for use. Both are carbon black formulations that are used for
endoscopically tattooing or marking the colon.
The Black Eye Endoscopic Marking System provides a method of marking cancerous lesions on the
wall of a patient's stomach or colon during an endoscopic procedure. The mark provides a reference
point for subsequent removal of the tissue. The inexpensive packaging solution turned the
technology into a product, by creating a whimsical brand identity that uses color and simple
iconography that make it appear less threatening, thereby reducing user anxiety.
Why it's better for your patients
lt's safe.
India ink preparations contain shellac, phenol and ammonia that, even in dilute solutions, should be avoided. Black Eye's biocompatible. Non-toxic formulation contains no India lnk.
lt's sterile.
Black Eye is a single use product so sterility is easily maintained. Each syringe is stream-sterilized prior to packaging and shipping.
Each syringe is prefilled.
Preparation is simplified thanks to Black Eye's ready-to-use product design. Each syringe comes with Scc of the marking fluid.
Just shake it vigorously prior to use.
lt's easy to work with.
Black Eye is easier to use than lndia-ink-based markers, and it has a shelf life of two years.
Packing 5ml syringe, box of 10.
0120
THE STANDARD CO, LTD.
Jdh 1007, Digital 2cha Valley, Byucksan, #481 -1O, Gasan-dong, Gaumchaon-gu, Seoul, Korea.
Tel: 82-2-838-5533. Fax 82-2-838-5523,[email protected] www.thestandard.co.kr
www.thestandard.co.kr
114 TRANSMÉDICA ------------------------ TRANSMÉDICA 115
1 Non-India lnk based CE aooroved tattoo lnk. 1
ENDOSCOPIC MARKER
Mort<lng
Poncteotic l"'ilor.s'{'
o
Bartett 1
W ESOPhogos
e PREF1LLED NOMIXING
e STERILE
e BIOCOMPATIBLE
e NON-PYROGEN1C
e PERIIAHENT
COLOR-OARKER, LONGER LAST1 NG THAH INDIA INK
Poot Potypectomy
Survelllonco
- THE STANOARO CO_ LTD•
.rt()(l6. UW.GasandigitaJ 1-ro. Geumcbeon gu.Seoul. 13-783. Korea
Te:! 82·1·83.8·5533. Fu::82 2-838·5Slltn.b:m@thestd co.kr. WWol(.thf'standatd.coJu
120 TRANSMÉDICA -------------- - - - -- - : :--------------------------- TRANSMÉDICA 117
TRANSMÉDICA 119 64 TRANSMÉDICA
CLINICAL DATA
A recent clinical trial of 22 patients (16 pancreatic,
6 cholangiocarcinoma) was reported in
Gastrointestinal Endoscopy Journal (GIE). The
patients were treated with the EndoHPB catheter
between January 2009 and April 2010 and the
study was conducted to demonstrate safety and
report on 90 day biliary patency. Deployment of the
catheter was successful in 21 patients. Self
Expanding Metal Stent (SEMS) placement was
achieved in all cases after deployment of our
catheter (Steel et al, GIE 2011;73:149-153).
In another trial, the Imperial College team have also
observed a statistically significant improvement in
survival at 3 months and 6 months in patients
treated with intraductal RF ablation compared to a
retrospective cohort treated only with SEMS (pre-
publication data).
USAGE
The HabibTM EndoHPB can be used with a range of
commonly available RF generators. The purchase of
a corresponding adapter cable is required.
PUBLICATIONS
Feng X, Pai M, Mizandari M, Chikovani T, Spalding D,
Jiao L, Habib N. Towards the optimization of
management of hepatocellular carcinoma. Frontiers
of Medicine 2011;5(3):271-27
Steel AW., et al. Endoscopically applied
radiofrequency ablation appears to be safe in the
treatment of malignant biliary obstruction.
Gastrointestinal Endoscopy 2011;73(1):149- 153.
Monga A, Gupta R, Ramchamdani M, Rao GV,
Santosh D, Reddy N. Endoscopic radiofrequency
ablation of cholangiocarcinoma: a new palliative
treatment modality. Gastrointestinal Endoscopy,
2011; 20/10: 1-3.
Radiofrequenzablation bei malignen
Gallengangsstenosen: Eine Publikation – zwei
Meinungen! (in Austrian German)
Itoi T, et al. Evaluation of effects of a novel
endoscopically applied radiofrequency ablation
biliary catheter using an ex-vivo pig liver. Journal of
Hepato-Biliary-Pancreatic Sciences, 2011; Published
Online 25 October 2011: 1-5.
SmartBand™ Ligation System
Banding is our Business
PRODUCT NUMBER
6800
FDA STATUS
510(k) Cleared - Class II
Clearing of obstructed SEMS with HabibTM EndoHPB
SPECIFICATIONS
8Fr (2.6mm), Useable Length
180cm
SHELF LIFE
3 Years
CE STATUS
Cleared - Class IIb
REQUIRED ACCESSORIES
EMcision generator adapter
cable
IMPORTANT 1Prior to use, refer to Instructions for Use supplied with the device for indications, contraindications, adverse effects, suggested
procedure, warnings, power settings and precautions.
A 90cm length catheter specifically for percutaneous use is available to order (product number 3700)
CONTACT: [email protected] MORE INFORMATION: WWW.EMCISION.COM
124 TRANSMÉDICA TRANSMÉDICA 121
120 TRANSMÉDICA TRANSMÉDICA 65
Product Specifications Used to endoscopically ligate esophageal varices at or above the gastroesophageal junction and to ligate
internal hemorrhoids
HabibTM
• High-retention bands contain less than half the latex proteins
compared to other banding devices*
• Specialized UV protected packaging maintains band performance for
up to 24 months shelf life
• Advanced friction-fit barrel design is compatible with the widest
range of upper GI endoscopes from 8.6mm – 11.6mm
• Revolutionary, single-hub ligation handle allows for
full-functionality with the simplicity of a one-way rotation for band deployment
• Larger handle stem inner diameter, 9.8Fr, ensures maximum space
for suction and flushing capabilities**
• Improve endoscopic view during the procedure by using the
dedicated flush port and connector tube for immediate irrigation
• The one-piece loading device utilizes PermaCoil™ technology
for reliable device assembly
• Use the standalone SmartBand Ligation Pack when additional bands
are required to complete the procedure
EndoHPB
Ablation of Tissue in the
Gastro-intestinal Tract
The HabibTM EndoHPB is a novel endoscopic bipolar radiofrequency
(RF) catheter used to ablate tissue in the gastro-intestinal tract.
SmartBand Ligation Kit
Components: Ligation Handle, Loading Device, Connector Tube and Deployment Cord with Barrel of Bands
Order
Number
Reference Part
Number
Barrel
Diameter (mm)
Number of
Bands
Band
Material
Shelf Life
(months)
IE11002 SLK-6 8.6 - 11.6 6 Latex 24
This device is supplied non-sterile and is disposable, single-use only
SmartBand Ligation Pack
Components: Deployment Cord with Barrel of Bands
Order
Number
Reference Part
Number
Barrel
Diameter (mm)
Number of
Bands
Band
Material
Shelf Life
(months)
IE11001 SLP-6 8.6 - 11.6 6 Latex 24
This device is supplied non-sterile and is disposable, single-use only
We have received 510(k) clearance by the FDA
“to assist in the coagulation of tissue during
Endoscopic surgical procedures in the
Gastrointestinal tract”. Endoscopists are using
this device on tumors in the bile duct and head
of the pancreas for partial tumor destruction
prior to stent insertion and to clear occluded
metal stents.
The HabibTM EndoHPB has an 8Fr (2.6mm)
diameter, 180cm useable length and two
stainless steel electrodes at the distal tip. It is
compatible with endoscopes that have a
The catheter is introduced over a 0.035"
guidewire into the common bile duct (CBD) via
the Ampulla of Vater, where it is used to heat
and ablate tissue. Its electrodes are designed to
operate at an efficient energy level and are
activated at maximum 10 Watts for only 90
seconds1 before the device is removed and a
stent inserted. The EndoHPB’s safety and
efficacy have been established by a growing
number of publications in medical journals and
the device has been successfully used in
hundreds of patients throughout the world with
no perforations of the bile duct wall reported. *Data on file at Intelligent Endoscopy
**Not compatible with Pentax® endoscopes. Pentax is a registered trademark of Pentax Medical. working channel of 3.2mm or greater.
CONTACT: [email protected] MORE INFORMATION: WWW.EMCISION.COM
© IE 2014 SLS-022015
122 TRANSMÉDICA TRANSMÉDICA 123