2
3) electrical connections a) connect ac power to the charger ac source VOLTAGE tag on ac breaker all these parameters must match ! b) connect the battery or dc bus BATTERY OR FACTORY PRESET VOLTAGES DC BUS 4) starting the charger recheck your wiring! if it is correct, follow the start sequence below ac source distribution panel Turn ac breaker on Turn dc breaker on 1 2 3 4 5) setting THE parameters JC5020-01 ac volts & phase warning tag WARNING JC0011-00 This Unit Has Been Connected For An Output Of Volts Phase JC0016-00 adjustable parameters (in selection order): 1) float voltage 2) equalize voltage 3) equalize timer hours 4) high dc voltage alarm 5) low dc voltage alarm 6) current limit 1) location CHECK ONCE COMPLETED place the charger in a well ventilated area dc source or battery disconnect switch 2) safety first disconnect and lock-out all ac sources and dc battery voltages Ac input voltage battery charger data nameplate BATTERY CHARGER / RECTIFIER INPUT OUTPUT AT Series V www.atseries.net AT DC AMPERES AT Advanced Technology BATTERY CHARGER RECTIFIER SERIES DC VOLTS EQLZ HRS REMAINING FLOAT EQLZ AC ON MANUAL TIMER MANUAL EQLZ AUTO EQLZ TIMER RESET LAMP TEST ADJUST METER MODE CHRG MODE EQLZ MTHD EDIT ENTER HIGH DC VOLTAGE LOW DC VOLTAGE DC OUTPUT FAILURE AC INPUT FAILURE POS GND NEG GND 125.5 ac source disconnect switch off & LOCKED Do Not Connect To Other Voltage Without Reconnecting Input Transformer - See Instruction Manual TURN ON Turn ON press the enter key once to begin the adjustment process. the first value (float voltage) will be displayed. adjust this value by pressing the up or down arrow keys. press “enter” again to save and advance to the next parameter For adjustment. repeat this process to adjust the rest of The parameters listed above. if no keys are pressed for 25 seconds, the charger will return to normal operation. For further instructions be sure to read the operating and service instructions or visit online at ... NOTICE DC Output Charging Voltages Have Been Preset At The Factory As Follows These Voltages Are Adjustable Please Consult Operating Manual Output Current Limit Has Been Set At DC Amps Float Mode: Equalize Mode: Volts Volts At The Factory As Follows These Voltages Are Float Mode: Equalize Mode: Volts Volts off & locked tag on dc breaker HOT AIR COOL AIR 6in /153mm 6in /153mm AT AT QUICK SET-up SHEET please check the operating instructions provided with your battery for proper charging voltages AT AT

COMPLETED ICK - HindlePowervoltage dc volts low voltage dc amps ac on ac on ac on ac on ac on ac on 132.7 139.7 48 144.3 120.0 27.5 jc5020-01 5-2) setting the equalize voltage 5-3)

  • Upload
    others

  • View
    8

  • Download
    0

Embed Size (px)

Citation preview

Page 1: COMPLETED ICK - HindlePowervoltage dc volts low voltage dc amps ac on ac on ac on ac on ac on ac on 132.7 139.7 48 144.3 120.0 27.5 jc5020-01 5-2) setting the equalize voltage 5-3)

3) electrical connectionsa) connect ac power to the charger

ac sourceVOLTAGE

tag onac breaker

all these parameters must match !

b) connect the battery or dc bus

BATTERY ORFACTORY PRESETVOLTAGES DC BUS

4) starting the chargerrecheck your wiring! if it is correct, follow the start sequence below

ac sourcedistribution

panel

Turn acbreaker on

Turn dcbreaker on

1

2

3

4

5) setting THE parameters

JC5020-01

ac volts& phase

warning tag

WARNING

JC0011-00

This Unit Has Been Connected For An Output Of

Volts

Phase

JC0016-00

adjustable parameters (in selection order):

1) float voltage

2) equalize voltage

3) equalize timer hours

4) high dc voltage alarm

5) low dc voltage alarm

6) current limit

1) location

CHECK ONCE COMPLETED

place the charger in a well ventilated area

dc sourceor batterydisconnectswitch

2) safety firstdisconnect and lock-out all ac sources and dc battery voltages

Ac inputvoltage

battery chargerdata nameplate

BATTERY CHARGER / RECTIFIER

INPUT OUTPUT

AT Series

V

www.atseries.net

AT

DC AMPERES

ATAdvanced Technology

BATTERY CHARGERRECTIFIER

SERIES

DC VOLTS

EQLZ HRSREMAINING

FLOAT

EQLZ

AC ON

MANUAL TIMER

MANUAL EQLZ

AUTO EQLZ TIMER

RESET LAMP TEST

ADJUST

METERMODE

CHRGMODE

EQLZMTHD

EDITENTER

HIGH DCVOLTAGE

LOW DCVOLTAGE

DC OUTPUTFAILURE

AC INPUTFAILURE

POS GND

NEG GND

125.5

ac sourcedisconnect

switch

off &LOCKED

Do Not Connect ToOther Voltage Without

Reconnecting InputTransformer - SeeInstruction Manual

TURNON

TurnON

press the enter key once to begin the adjustment process. the first value (float voltage) will be displayed. adjustthis value by pressing the up or down arrow keys. press“enter” again to save and advance to the next parameterFor adjustment. repeat this process to adjust the rest ofThe parameters listed above.

if no keys are pressed for 25 seconds, the charger will return to normal operation.

For further instructions be sure to read the operating andservice instructions or visit online at ...

NOTICEDC Output Charging VoltagesHave Been PresetAt The Factory As Follows

These Voltages AreAdjustable Please Consult Operating Manual

Output Current LimitHas Been Set At

DC Amps

Float Mode:

Equalize Mode:

Volts

Volts

NOTEDC Output Charging VoltagesHave Been PresetAt The Factory As Follows

These Voltages AreAdjustable Please Consult Operating Manual

Output Current LimitHas Been Set At

DC Amps

Float Mode:

Equalize Mode:

Volts

Volts

off &locked

tag ondc breaker

HOT AIR

COOL AIR

6in/153mm

6in/153mm

AT

AT

QUICK

SET-up

SHEET

please check the operating instructions provided with your battery

for proper charging voltages

AT

AT

Page 2: COMPLETED ICK - HindlePowervoltage dc volts low voltage dc amps ac on ac on ac on ac on ac on ac on 132.7 139.7 48 144.3 120.0 27.5 jc5020-01 5-2) setting the equalize voltage 5-3)

5-1) SETTING THEFLOAT VOLTAGE

- PRESS EDIT/ENTER KEY

see Manualsection2.32

see Manualsection2.32

see Manualsection2.33

see Manualsection2.34

see Manualsection2.34

see Manualsection2.35

- PRESS THE ARROW KEYS

- PRESS EDIT/ENTER KEYWILL SAVE YOUR CHANGESAND GO TO THE NEXT PARAMETER

DC VOLTS

EQLZ

EQLZ HRSREMAINING

AUTO EQLZ TIMER

MANUAL TIMER

DC VOLTS

FLOAT

DC VOLTS

HIGH DCVOLTAGE

DC VOLTS

LOWVOLTAGE

DC AMPS

AC ON

AC ON

AC ON

AC ON

AC ON

AC ON

132.7

139.7

48

144.3

120.0

27.5

jc5020-01

5-2) SETTING THEEQUALIZE VOLTAGE

5-3) SETTING THEEQUALIZETIMER HOURS

5-4) SETTING THEHIGH DC VOLTAGEALARM

5-5) SETTING theLOW DC VOLTAGEALARM

5-6) SETTING theCURRENT LIMIT

RED DC VOLTS LED WILL FLASHGREEN FLOAT LED WILL FLASHLCD DISPLAY WILL FLASH THE FLOAT VOLTAGE

UP ARROW KEY WILL INCREASEDOWN ARROW WILL DECREASE

- PRESS EDIT/ENTER KEY

- PRESS THE ARROW KEYS

- PRESS EDIT/ENTER KEYWILL SAVE YOUR CHANGESAND GO TO THE NEXT PARAMETER

UP ARROW KEY WILL INCREASEDOWN ARROW WILL DECREASE

- PRESS EDIT/ENTER KEY

- PRESS THE ARROW KEYS

- PRESS EDIT/ENTER KEYWILL SAVE YOUR CHANGESAND GO TO THE NEXT PARAMETER

UP ARROW KEY WILL INCREASEDOWN ARROW WILL DECREASE

- PRESS EDIT/ENTER KEY

- PRESS THE ARROW KEYS

- PRESS EDIT/ENTER KEYWILL SAVE YOUR CHANGESAND GO TO THE NEXT PARAMETER

UP ARROW KEY WILL INCREASEDOWN ARROW WILL DECREASE

- PRESS EDIT/ENTER KEY

- PRESS THE ARROW KEYS

- PRESS EDIT/ENTER KEYWILL SAVE YOUR CHANGESAND GO TO THE NEXT PARAMETER

UP ARROW KEY WILL INCREASEDOWN ARROW WILL DECREASE

- PRESS EDIT/ENTER KEY

- PRESS THE ARROW KEYS

- PRESS EDIT/ENTER KEYWILL SAVE YOUR CHANGESAND GO TO THE NEXT PARAMETER

UP ARROW KEY WILL INCREASEDOWN ARROW WILL DECREASE

RED DC VOLTS LED WILL FLASHYELLOW EQLZ LED WILL FLASHLCD DISPLAY WILL FLASH THE EQLZ VOLTAGE

RED EQLZ HRS REMAINING LED WILL FLASHYELLOW LEDS MANUAL TIMER AND AUTO-EQLZ TIMER WILL FLASHLCD DISPLAY WILL FLASH THE EQLZ HOURS

RED DC VOLTS LED WILL FLASHRED LOW DC VOLTAGE WILL FLASHLCD DISPLAY WILL FLASH THE LOW DC VOLTAGE ALARM

RED DC VOLTS LED WILL FLASHred low dc volts will flashLCD display will flash the low dc voltage alarm

RED DC AMPS LED WILL FLASHLCD DISPLAY WILL FLASH THE LIMIT SETTINGS

please check the operating instructions provided with your battery

for proper charging voltages