TECHNOLOGIESFFFFFFUUUUUUTTTTTTUUUUUURRRRRREEEEEE
TM
Complete Optical Fibre Solutions
www.b3ft.com
featuring the
the future of communication
www.b3ft.com
is a comprehensive range of products designed for all aspects of the
fi bre optic network. Encompassing ducts & chambers, fi bre cables & connectivity
and accessories & installation/testing equipment, truly provides the
complete FTTX solution.
In a world where technological development never stands still it is essential to keep pace
with constantly advancing parameters and the ever changing requirements of a highly
demanding marketplace.
Education, healthcare, communication, security and the multi-faceted broadcast and
entertainment industries all rely on the provision of world class optical fi bre technologies.
B3 Future Technologies (B3FT) is an international and innovative manufacturer working at
the forefront of optical fi bre provision, offering complete solutions encompassing cabling
and infrastructure products for all sectors - industry, commerce, education, healthcare
and at home.
B3FT is one of the world’s most established manufacturers
and with a wide ranging network of operations is able to
provide a fi rst class service throughout Europe, Asia
and the Middle East.
The future of communication technology is without doubt
in optical fi bre, B3FT are part of that future...today.
www.b3ft.com
B3FT’s on-going expansion programme took a huge step forward in 2008 with the acquisition of a cable manufacturing plant in Santander, Spain. Signifi cant investment in both people and machinery means that B3FT can now boast one of Europe’s leading cable manufacturing facilities.
As a result of this investment in Santander, B3FT produces a wide range of optical fi bre
cables from drop cable to high fi bre count cables, cables for aerial, underground and
indoor installations.
Research and Development is key to providing fi rst class products and services. B3FT
Santander has state of the art testing facilities, allowing cables to be tested to extremes of
temperature and mechanical conditions. All of our products meet the high EU standards
and regulations.
B3FT SantanderProduction HQ
www.b3ft.com
a complete networkCombining the three major network areas, the Range of products are present in some of the world’s most advanced fi bre to the home networks.
Mass transportation, schools, shopping centres, offi ces and homes rely on B3FT to provide
essential bandwidth and communications, which today are taken for granted by end users.
TECHNOLOGIESFFFFFFUUUUUUTTTTTTUUUUUURRRRRREEEEEE
TM BACKBONE / CITY NETWORK Connecting all cities and municipalities
ACCESS NETWORK Connecting local areas
IN-BUILDING NETWORK Connecting the end user
Please note: The above cables are available in the range 12 - 256 fi bresThe cables are also available in LS-HFFR version, with an external sheath ofLow Smoke Flame Retardant outer sheath: I-012-SM2-L12-D-W-KTThe cables are also available in double sheath construction version:E-012-SM2-L12-D-W-PKP The cables have been tested to show compliance withEuropean Norm (EU) 187000. 501 - Max Tensile Load, 504 - Crush Values,513 - Bend, 601 - Temperature Cycling, and 605B - Water Penetration.
B3P/N
No. ofFibres
No.Tubes
No. FibresPer Tube
Cable Diameter
(mm)
Min Bend Radius(mm)
E-012-SM2-L12-D-W-KP 12 1 12 12.5 187.5
E-024-SM2-L12-D-W-KP 24 2 12 12.5 187.5
E-048-SM2-L12-D-W-KP 48 4 12 12.5 187.5
E-096-SM2-L12-D-W-KP 96 8 12 17.0 255.0
E-144-SM2-L12-D-W-KP 144 12 12 20.0 300.0
Dielectric Loose Tube for Pulled-in Installation TechniqueDielectric strength member, gel fi lled loose tubes with 12 singlemode fi bres per tube (G652 or G655), fi llers where required for cable geometry, water swellable elements of tapes or yarns, peripheral strength elements of aramid or glass, PE outer sheath.
BACKBONE/CITY NETWORKCables
Backbone and City networks are the mainarteries of major communication systems.
products defi ne and complement all aspects of these architectures.
B3P/N
No. ofFibres
No.Tubes
No. FibresPer Tube
Cable Diameter
(mm)
Min Bend Radius(mm)
E-012-SM2-L12-D-W-PKP 12 1 12 12.5 187.5
E-024-SM2-L12-D-W-PKP 24 2 12 12.5 187.5
E-048-SM2-L12-D-W-PKP 48 4 12 12.5 187.5
E-096-SM2-L12-D-W-PKP 96 8 12 17.0 255.0
E-144-SM2-L12-D-W-PKP 144 12 12 20.0 300.0
Dielectric Loose TubeDielectric strength member, gel fi lled loose tubes with 2 - 16 singlemode fi bres per tube (G652 or G655), fi llers where required for cable geometry,water swellable elements of tapes or yarns, PE inner sheath (optional), peripheral strength elements of aramid or glass, PE outer sheath.
Please note: The above cables are available in the range 8 - 256 fi bres, with a double sheath option. The cables are also available in LS-HFFR version, with an external sheath of Low Smoke Flame Retardant outer sheath: I-012-SM2-L12-D-W-TKT. The cables have been tested to show compliance with European Norm (EU) 187000. 501 - Max Tensile Load, 504 - Crush Values, 513 - Bend, 601 - Temperature Cycling, and 605B - Water Penetration.
B3P/N
No. ofFibres
No.Tubes
No. FibresPer Tube
Cable Diameter
(mm)
Min Bend Radius(mm)
E-016-SM2-L04-D-W-PSP 16 4 4 14.5 220.0
E-032-SM2-L08-D-W-PSP 32 4 8 14.5 220.0
E-048-SM2-L08-D-W-PSP 48 6 8 14.5 220.0
E-096-SM2-L08-D-W-PSP 96 8 12 16.5 250.0
E-192-SM2-L16-D-W-PSP 192 12 16 21.5 400.0
Dielectric Loose TubeDielectric strength member, gel fi lled loose tubes with 2 - 16 singlemode fi bres per tube (G652 or G655), fi llers where required for cable geometry, water swellable elements of tapes or yarns, PE inner sheath (optional), laminated steel tape, PE outer sheath.
Please note: The above cables are available in the range 8 - 256 fi bres, with a double sheath option. The cables are also available in LS-HFFR version, with an external sheath of Low Smoke Flame Retardant outer sheath: I-016-SM2-L04-D-W-TST. The cables have been tested to show compliance with European Norm (EU) 187000. 501 - Max Tensile Load, 504 - Crush Values, 513 - Bend, 601 - Temperature Cycling, and 605B - Water Penetration.
Please note: The above cables are available in the range 12 - 256 fi bres. They have been tested to show compliance with European Norm (EU) 187000.501 - Max Tensile Load, 504 - Crush Values, 513 - Bend, 601 - Temperature Cycling, and 605B - Water Penetration.
Dielectric Loose Tube for Short-span AerialInstallation TechniqueDielectric strength member, gel fi lled loose tubes with 12 singlemode fi bres per tube (G652 or G655), fi llers where required for cable geometry, water swellable elements of tapes or yarns, PE inner sheath peripheral strength elements of aramid or glass, PE outer sheath.
B3P/N
No. ofFibres
No.Tubes
No. FibresPer Tube
Cable Diameter
(mm)
Min Bend Radius(mm)
A-012-SM2-L12-D-W-PKP 12 1 12 14.5 217.5
A-024-SM2-L12-D-W-PKP 24 2 12 14.5 187.5
A-048-SM2-L12-D-W-PKP 48 4 12 14.5 187.5
A-096-SM2-L12-D-W-PKP 96 8 12 19.0 255.0
A-144-SM2-L12-D-W-PKP 144 12 12 22.0 300.0
ADSS Cable - All Dielectric Self-Supporting CableDielectric strength member, gel fi lled loose tubes with 2 - 12 singlemode fi bres per tube (G652 or G655), fi llers where required for cable geometry, water swellable elements of tapes or yarns, PE inner sheath, peripheral strength elements of aramid, PE outer sheath.
Please note: The above cables are available in the range 8 - 256 fi bres.The cables have been tested to show compliance with European Norm (EU) 187000. 501 - Max Tensile Load, 504 - Crush Values, 513 - Bend,601 - Temperature Cycling, and 605B - Water Penetration.
B3P/N
No. ofFibres
No.Tubes
No. FibresPer Tube
Cable Diameter
(mm)
Min Bend Radius(mm)
A-016-SM2-L12-D-W-PKP 12 1 12 14.0 210.0
A-032-SM2-L12-D-W-PKP 24 2 12 14.0 210.0
A-048-SM2-L12-D-W-PKP 48 4 12 14.0 210.0
A-096-SM2-L12-D-W-PKP 96 8 12 19.0 285.0
A-192-SM2-L12-D-W-PKP 144 12 12 24.0 350.0
www.b3ft.com
ACCESS NETWORK Cables
Access Networks link the main network nodes with the localities. Here the connection with the high traffi c city networks is critical. products bridge these with ease, keeping the customer connected at all times.
B3P/N
No. ofFibres
No.Tubes
No. FibresPer Tube
Cable Diameter
(mm)
Min Bend Radius(mm)
E-012-SM2-L12-D-W-P 12 1 12 9.5 114.0
E-024-SM2-L12-D-W-P 24 2 12 9.5 114.0
E-048-SM2-L12-D-W-P 48 4 12 9.5 114.0
E-096-SM2-L12-D-W-P 96 8 12 11.0 132.0
E-144-SM2-L12-D-W-P 144 12 12 13.6 163.2
Dielectric Loose Tube for Blown Installation TechniqueDielectric strength member, gel fi lled loose tubes with 12 singlemode fi bres per tube (G652 or G655), fi llers where required for cable geometry, water swellable elements of tapes or yarns, peripheral strength elements of aramid or glass (optional), PE outer sheath.
Please note: The above cables are available in the range 12 - 256 fi bresThe cables are also available in LS-HFFR version, with an external sheath of Low Smoke Flame Retardant outer sheath: I-012-SM2-L12-D-W-T. The cables have been tested to show compliance with European Norm (EU) 187000. 501 - Max Tensile Load, 504 - Crush Values, 513 - Bend, 601 - Temperature Cycling, and 605B - Water Penetration.
www.b3ft.com
B3P/N
No. ofFibres
No.Tubes
No. FibresPer Tube
Cable Diameter
(mm)
Min Bend Radius(mm)
I-016-SM2-L04-D-W-TST 16 4 4 14.5 260.0
I-032-SM2-L08-D-W-TST 32 4 8 14.5 260.0
I-048-SM2-L08-D-W-TST 48 6 8 14.5 260.0
I-096-SM2-L12-D-W-TST 96 8 12 16.5 360.0
I-192-SM2-L16-D-W-TST 192 12 16 21.0 420.0
Metallic Loose Tube with Anti-rodent ProtectionDielectric strength member, gel fi lled loose tubes with 2 - 16 singlemode fi bres per tube (G652), fi llers where required for cable geometry, water swellable elements of tapes or yarns, HFFR inner sheath (optional), laminated steel tape, HFFR outer sheath.
Please note: The above cables are available in the range 8 - 256 fi bres, with a double sheath option. The cables are also available in PE version, with an external sheath of PE outer sheath: E-016-SM2-LO4-D-W-PSP. The cables have been tested to show compliance with European Norm (EU) 187000. 501 - Max Tensile Load, 504 - Crush Values, 513 - Bend, 601 - Temperature Cycling, and 605B - Water Penetration.
B3P/N
No. ofFibres
No.Tubes
No. FibresPer Tube
Cable Diameter
(mm)
Min Bend Radius(mm)
I-016-SM2-L04-D-W-TET 16 4 4 13.0 114.0
I-032-SM2-L08-D-W-TET 32 4 8 13.0 114.0
I-048-SM2-L08-D-W-TET 48 6 8 13.0 114.0
I-096-SM2-L12-D-W-TET 96 8 12 15.0 132.0
I-192-SM2-L16-D-W-TET 192 12 16 20.0 163.2
Dielectric Anti-rodent Protected Loose TubeDielectric strength member, gel fi lled loose tubes with 2 - 16 singlemode fi bres per tube (G652), fi llers where required for cable geometry, water swellable elements of tapes or yarns, HFFR inner sheath (optional), peripheral strength elements of aramid or glass, HFFR outer sheath.
Please note: The above cables are available in the range 8 - 256 fi bres, with a double sheath option. The cables are also available in PE version, with an external sheath of PE outer sheath: E-016-SM2-L04-D-W-PEP. The cables have been tested to show compliance with European Norm (EU) 187000. 501 - Max Tensile Load, 504 - Crush Values, 513 - Bend, 601 - Temperature Cycling, and 605B - Water Penetration.
Please note: The above cable is available in the range 12 - 144 fi bres.Cables are also available in a double sheath confi guration. The cables have been tested to show compliance with European Norm (EU) 187000. 501 - MaxTensile Load, 504 - Crush Values, 513 - Bend, 601 - Temperature Cycling, and605B - Water Penetration.
B3P/N
No. ofFibres
No.Tubes
No. FibresPer Tube
Cable Diameter
(mm)
Min Bend Radius(mm)
A-012-SM2-L12-D-W-PKCP 12 1 12 15.0 210.0
A-024-SM2-L12-D-W-PKCP 24 2 12 15.0 210.0
A-048-SM2-L12-D-W-PKCP 48 4 12 15.0 210.0
A-072-SM2-L12-D-W-PKCP 72 6 12 15.0 210.0
Aerial Short-span Dielectric Loose Tube Cable -Shot Gun ProtectedDielectric strength member, gel fi lled loose tubes with 2 - 16 singlemode fi bres per tube (G652 or G655), fi llers where required for cable geometry, water swellable elements of tapes or yarns, PE inner sheath (optional), peripheral strength elements of aramid, shot-gun protection tape, PE outer sheath.
B3P/N
No. ofFibres
No.Tubes
No. FibresPer Tube
Cable Diameter
(mm)
Min Bend Radius(mm)
A-012-SM2-L12-D-W-AP8 12 1 12 12.5 210.0
A-024-SM2-L12-D-W-AP8 24 2 12 12.5 210.0
A-048-SM2-L12-D-W-AP8 48 4 12 12.5 210.0
A-072-SM2-L12-D-W-AP8 72 6 12 12.5 210.0
Aerial Figure 8 Metallic Loose Tube CableDielectric strength member, gel fi lled loose tubes with 2 - 12 singlemode fi bres per tube (G652 or G655), fi llers where required for cable geometry,water swellable elements of tapes or yarns, PE inner sheath (optional), laminated aluminium copolymer tape, metallic messenger (fi g 8) and PE outer sheath.
ACCESS NETWORK Cables(continued)
B3P/N
No. ofFibres
No.Tubes
No. FibresPer Tube
Cable Diameter
(mm)
Min Bend Radius(mm)
E-016-SM2-L04-D-W-KPSP 12 1 12 7.2 72.0
E-032-SM2-L08-D-W-KPSP 12 1 12 7.2 72.0
E-048-SM2-L08-D-W-KPSP 12 1 12 7.2 72.0
E-096-SM2-L08-D-W-KPSP 12 1 12 7.2 72.0
E-192-SM2-L16-D-W-KPSP 12 1 12 7.2 72.0
Monotube Dielectric Cable Dielectric strength member, gel fi lled loose tube with up to 24 fi bres per tube (G652 or G657), or multimode fi bres (G651 - OM1, OM2 or OM3), water swellable elements of tapes or yarns, peripheral strength elements of aramid or glass, Hydrocarbon-resistant sheathing compound.
Please note: The cables are also available in LS-HFFR version, with an external sheath of Low Smoke Flame Retardant outer sheath: I-012-SM2-C12-D-W-ETThe cables have been tested to show compliance with European Norm (EU) 187000. 501 - Max Tensile Load, 504 - Crush Values, 513 - Bend, 601 - Temperature Cycling, and 605B - Water Penetration.
B3P/N
No. ofFibres
No.Tubes
No. FibresPer Tube
Cable Diameter
(mm)
Min Bend Radius(mm)
E-016-SM2-L04-D-W-KPSP 16 4 4 14.5 260.0
E-032-SM2-L08-D-W-KPSP 32 4 8 14.5 260.0
E-048-SM2-L08-D-W-KPSP 48 6 8 14.5 260.0
E-096-SM2-L08-D-W-KPSP 96 12 8 18.5 360.0
E-192-SM2-L16-D-W-KPSP 192 12 16 21.5 420.0
Metallic Loose Tube with Anti-rodent Resistance Dielectric strength member, gel fi lled loose tube with 2 - 16 singlemode fi bres per tube (G652), fi llers where required for cable geometry, water swellable elements of tapes or yarns, peripheral strength elements of aramid, PE inner sheath (optional), laminated steel tape, PE outer sheath.
Please note: The above cables are available in the range 8 - 256 fi bres, witha double sheath option. The cables are also available in HFFR version, with an internal sheath of HFFR outer sheath: I-016-SM2-L04-D-W-KTST. The cables have been tested to show compliance with European Norm (EU) 187000.501 - Max Tensile Load, 504 - Crush Values, 513 - Bend, 601 - Temperature Cycling, and 605B - Water Penetration.
www.b3ft.com
B3P/N
No. ofFibres
No.Tubes
No. FibresPer Tube
Cable Diameter
(mm)
Min Bend Radius(mm)
E-016-SM2-L04-D-W-KPSP 12 1 12 7.2 72.0
E-032-SM2-L08-D-W-KPSP 12 1 12 7.2 72.0
E-048-SM2-L08-D-W-KPSP 12 1 12 7.2 72.0
E-096-SM2-L08-D-W-KPSP 12 1 12 7.2 72.0
E-192-SM2-L16-D-W-KPSP 12 1 12 7.2 72.0
Monotube Armoured Cable Dielectric strength member, gel fi lled loose tube with up to 24 fi bres per tube (G652 or G657), or multimode fi bres (G651 - OM1, OM2 or OM3), water swellable elements of tapes or yarns, peripheral strength elements of aramid or glass, PE inner sheath (optional), Laminated steel tape, PE outer sheath.
Please note: The cables are also available in LS-HFFR version, with an external sheath of Low Smoke Flame Retardant outer sheath: I-012-SM2-C12-D-W-VTSTThe cables are also available in Hydrocarbon-resistant sheathing compound, with an external sheath of hydrocarbon-resistant outer sheath: I-012-SM2-C12-D-W-VPSPD. The cables have been tested to show compliance with European Norm (EU) 187000. 501 - Max Tensile Load, 504 - Crush Values, 513 - Bend, 601 - Temperature Cycling, and 605B - Water Penetration.
B3P/N
No. ofFibres
No. Tubes
No. Fibres
Per Tube
No.Fillers
Cable Diameter
(mm)
Min BendRadius (mm)
Dynamic Static
30-1024-118-0 24 2 12 2 5.0 100 50
30-1036-129-0 36 3 12 1 5.0 100 50
30-1048-119-0 48 4 12 0 5.0 100 50
30-1064-130-0 64 5 12 1 5.9 118 59
30-1072-120-0 72 6 12 0 5.9 118 59
30-1096-121-0 96 8 12 0 7.0 140 70
30-1144-122-0 144 12 12 0 9.2 184 92
Please note: The above cable is available in the range 24 - 144 fi bres.Cables are also available with optional Nylon Sheath. The cables have been tested to show compliance with European Norm (EU) 187000. 501 - MaxTensile Load, 504 - Crush Values, 513 - Bend, 601 - Temperature Cycling, and605B - Water Penetration
Please note: The above cable is available in the range 2 to 24 fi bres with Singlemode and Multimode options. Cables are also available with optional Nylon Sheath. The cables have been tested to show compliance with European Norm (EU) 187000. 501 - Max. Tensile Load, 504 - Crush Values, 513 - Bend, 601 - Temperature Cycling, and 605B - Water Penetration.
Microcables MultitubeMicrocable 24-144 fi bres. Dielectric Loose Tube Microcable for Air blown installation technique. Dielectric strength member, gel fi lled loose tubes with 12 singlemode fi bres per tube (G652), fi llers where required for cable geometry, PE outer sheath, nylon optional.
B3P/N
No. ofFibres Fibre Type
Cable Diameter
(mm)
Min BendRadius (mm)
Dynamic Static
30-1002-108-0 2 G652D 9/125µm 3.0 60 30
30-1004-109-0 4 G652D 9/125µm 3.2 64 32
30-1008-110-0 8 G652D 9/125µm 3.2 64 32
30-1012-111-0 12 G652D 9/125µm 3.2 64 32
30-1016-128-0 16 G652D 9/125µm 4.0 80 40
30-1024-112-0 24 G652D 9/125µm 4.2 84 42
Microcable MonotubeMonotube Dielectric Microcable for Air Blown installation technique. Dielectric strength member, gel fi lled loose tube with 2 to 24 singlemode fi bres per tube (G652 or G657), or multimode fi bres (G651 - OM1, OM2 or OM3), peripheral strength elements of aramid or glass, PE outer sheath, nylon optional.
B3P/N
No. ofFibres
No.Tubes
No. FibresPer Tube
Cable Diameter
(mm)
Min Bend Radius(mm)
E-016-SM2-L04-D-W-KPSP 12 1 12 7.2 72.0
E-032-SM2-L08-D-W-KPSP 12 1 12 7.2 72.0
E-048-SM2-L08-D-W-KPSP 12 1 12 7.2 72.0
E-096-SM2-L08-D-W-KPSP 12 1 12 7.2 72.0
E-192-SM2-L16-D-W-KPSP 12 1 12 7.2 72.0
Metallic Loose Tube Dielectric strength member, gel fi lled loose tube with 2 - 16 singlemode fi bres per tube (G652 or G655), fi llers where required for cable geometry, water swellable elements of tapes or yarns, PE inner sheath (optional), laminated steel tape, PE outer sheath.
Please note: The above cables are available in the range 8 - 256 fi bres, with a double sheath option.The cables are also available in LS-HFFR version, with an external sheath of Low Smoke Flame Retardant outer sheath: I-016-SM2-L04-D-W-TST.The cables are also available in Hydrocarbon-resistant sheathing compound, with an external sheath of hydrocarbon-resistant outer sheath: I-016-SM2-L04-D-W-PSPD. The cables have been tested to show compliance with European Norm (EU) 187000. 501 - Max Tensile Load, 504 - Crush Values, 513 - Bend, 601 - Temperature Cycling, and 605B - Water Penetration.
IN-BUILDING NETWORK Cables
Translating the ‘network’ into the many broadband services used for commercial and domestic buildings, products are functional, secure and aesthetic. Providing the customer with safe, secure links to the outside world.
Breakout Cables 24 - 144 Dielectric strength member, Tight Buffered Fibre (s), dielectric peripheral strength members, PVC or LSZH sheath. Singlemode fi bres (G652 or G657) or multimode fi bres (G651 - OM1, OM2 or OM3).
B3P/N
No. ofFibres
No.Tubes
No. FibresPer Tube
Cable Diameter
(mm)
Min Bend Radius(mm)
I-024-SM2-B04-D-W-KVV 24 6 4 16.3 163
I-036-SM2-B06-D-W-KVV 36 6 6 17.6 176
I-048-SM2-B08-DW--KVV 48 6 8 19.3 193
I-072-SM2-B12-D-W-KVV 72 6 12 20.8 208
I-096-SM2-B12-D-W-KVV 96 8 12 24.8 248
I-144-SM2-B12-D-W-KVV 144 12 12 32.8 328
Please note: Temperature Multifi bre Breakout cables: Transport/Storage (°C) -20 to +60Installation (°C) -10 to +50Operational (°C) -20 to +60
B3P/N
No. ofFibres
No.Tubes
No. FibresPer Tube
Cable Diameter
(mm)
Min Bend Radius(mm)
E-012-SM2-C12-D-W-EP 12 1 12 7.2 72.0
E-012-SM7-C12-D-W-EP 12 1 12 7.2 72.0
E-012-OM1-C12-D-W-EP 12 1 12 7.2 72.0
E-012-OM2-C12-D-W-EP 12 1 12 7.2 72.0
E-012-OM3-C12-D-W-EP 12 1 12 7.2 72.0
Monotube Dielectric Cables for Drop Applications Dielectric strength member, gel fi lled loose tubes with up to 24 fi bres per tube (G652 or G657), or multimode fi bres (G651 - OM1, OM2 or OM3), water swellable elements of tapes or yarns, peripheral strength elements of aramidor glass, PE outer sheath.
Please note: The cables are also available in LS-HFFR version, with an external sheath of Low Smoke Flame Retardant outer sheath: I-012-SM2-C12-D-W-ETThe cables have been tested to show compliance with European Norm (EU) 187000. 501 - Max Tensile Load, 504 - Crush Values, 513 - Bend,601 - Temperature Cycling, and 605B - Water Penetration.
To fi nd out more about B3 Future Technologies products and services please visit www.b3ft.com
www.b3ft.com
B3P/N
MaxNo. ofFibres
Type
CableOverall
Diameter (mm)
Min Bend Radius(mm)
I-004-SM2-B01-D-W-V 4 Distribution 4.6 46
I-006-SM2-B01-D-W-V 6 Distribution 5.0 50
I-008-SM2-B01-D-W-V 8 Distribution 5.5 55
I-010-SM2-B01-D-W-V 10 Distribution 5.8 58
I-012-SM2-B01-D-W-V 12 Distribution 6.0 60
Breakout Cables 1 - 12Tight Buffered Fibre (s), dielectric peripheral strength members, PVC or LSZH sheath. Singlemode fi bres (G652 or G657) or multimode fi bres (G651 - OM1, OM2 or OM3).
Please note: Temperature Multifi bre Breakout cables: Transport/Storage (°C) -20 to +60Installation (°C) -10 to +50Operational (°C) -20 to +60
B3P/N
MaxNo. ofFibres
Type
CableOverall
Diameter (mm)
Min Bend Radius(mm)
I-001-SM2-T01-D-W-VSx* 1 Simplex 2.0 20
I-001-SM2-T01-D-W-VSx* 1 Simplex 3.0 20
I-002-SM2-T01-D-W-VDx 2 Duplex 3.2 32
I-002-SM2-T01-D-W-VDx 2 Duplex 5.4 54
I-002-SM2-T01-D-W-VDxg 2 DuplexShotgun 2.8x5.6 56
Simplex and Duplex Inbuilding Cables Tight Buffered Fibre (s), dielectric peripheral strength members, PVC or LSZH sheath. Singlemode fi bres (G652 or G657) or multimode fi bres (G651 - OM1, OM2 or OM3).
Please note: Temperature Rangeof Simples/Duplex cables: *Sx SimplexStorage (°C) -20 to +60 Dx DuplexOperational (°C) -10 to +50 Dxg Duplex shot-gun
Drop Cables Drop Cables with simple structure, common low weight making it easy to strip and splice
B3P/N
No. ofFibres
No.Tubes
No. FibresPer Tube
Cable Diameter
(mm)
Min Bend Radius(mm)
I-024-SM2-T02-D-W-KD 2 1 2 1.15 115
I-024-SM2-T04-D-W-KD 4 1 4 1.15 115
I-024-SM2-T06-D-W-KD 6 1 6 1.35 135
I-024-SM2-T08-D-W-KD 8 1 8 1.50 150
I-024-SM2-T12-D-W-KD 12 1 12 1.65 165
Application - Air assisted installationBlowing Length >1000m
Please note: B3FT also offers these cables pre-connected in fi xed lengths packed on cardboard reels for installation using the B3FT Blowing Pistol Model FBT-1.1
B3P/N
No. ofFibres Cable Core
Cable Diameter
(mm)
Min Bend Radius(mm)
30-1002-140-0 2 1 1.15 20.0
30-1004-141-0 4 1 1.15 20.0
30-1006-142-0 6 1 1.35 25.0
30-1008-143-0 8 1 1.50 35.0
30-1012-144-0 12 1 1.65 35.0
Tight Buffered Nano Cable for Air Blown ApplicationsResin encased fi bres within Low Friction, Low Smoke Zero Halogen Polymeric Sheath, 2 to 12 fi bres. Singlemode fi bres (G652D or G657A) or multimode fi bres (G651 - OM1, OM2 or OM3).
PREPARATION
Made with an aluminium body these microscopes are available in different strengths of 200x and 400x. Comes with universal adapter to fi t most ST, SC and FC connectors with other connector types as options.
Microscope
Range also offers a comprehensive range of accessories for optical fi bre cable installation and maintenance. With various fi bre preparation tools, splicing machines, test & measuring equipment and cleaning kits to name a few, B3FT have all the accessories you need.
ACCESSORIES
TOOLS
Optical fi bre stripping tools ranging from 127 to 305 microns. Using razor sharp blades and plastic heads which only make contact with the buffer and centre & support your work on both sides.
Designed to cut kevlar strength members in optical fi bre cables with a powerful quick cutting action.
www.b3ft.com
FIBRE SPLICING
TESTING AND MEASUREMENT FIBRE BLOWING INSTALLATION
PATCHCORDS AND PIGTAILS
CLEANING KIT
Automatic single and multimode fusion splicing machine. Mains and battery operated with simultaneous X and Y views. Includes 3D capability.
Rugged and compact design for demanding environmental conditions. Power saving technology allows up to 200 cycles (splicing and heating) with 2 built-in rechargeable batteries. Includes 3D capability.
A range of fi bre optic patchcords and pigtails available in simplex and duplex, single mode and multimode.
The complete optical fi bre care kit for inspection and cleaning of all optical fi bre & connector types including Plastic Optical Fibre [POF] systems. Supplied with Microscope and LASER Checker.
Optical power meter with high sensitivity large operation scope. 0.01dB resolution showing test value and wavelength at same time.
A hand held blowing tool, powered by a 12V battery, that can install 2-12 EPFU fi bres and connect to 3, 5 and 8mm microducts.
www.b3ft.com
a global responsibility
Now more than ever, business and industry need to be acutely aware of the effects their practices have on the environment both in the present and the long term.
B3 Future Technologies takes its responsibilities seriously and as such is working with
The Carbon Trust, Groundwork EBS and The Manufacturing Institute to calculate its carbon
footprint and reduce its impact on the environment by up to 25% in the next 10 years.
B3FT is one of the few companies within the industry to have an Environmental Manifesto:
• ISO 14001 certifi ed / ISO 18001 Certifi ed
• RoHS fully compliant (prior to the fi nal European directive)
• Full range of HFFR products
• 2011 target: reduction of 3% in power consumption
B3FT demonstrates duty of care by segregating all waste to maximise recycling opportunities
and minimise landfi ll. Examples include segregating all waste and working with recycling
agents to maximise yields of metals, polymer, wood and other materials. This service
provides B3FT’s customers with a “cradle to the grave” solution for all cable and related
products, whilst ensuring low whole life costs.
B3FT’s customers have been the main benefi ciaries in the recycling programme through -
• Re-use and refurbishment of existing products, saving expenditure
• Reduced space requirements for storage of products
• Compliance with recycling and waste legislation
These value added solutions in effective recycling are recognised by our customers and
demonstrate the focus environmental issues continue to have at B3FT.
www.b3ft.com
EXAMPLE: E-01-SM2-L12-D-W-KPExternal cable with 12 Singlemode G652D fi bres in Multifi bre Loose Tube construction with 12 fi bres per tube, Dielectric strength member, waterblocked, Aramid yarns and Polyethylene Sheath.
Optical Fibre Cables
identifi cation codes
ApplicationType:
E - External I - Indoor C - Indoor/OutdoorA - Aerial
A
Nº of Fibres
123
Fibre type:
SM2 - 9/125 SMF G652DSM7 - 9/125 SMF G657AOM1 - 62.5/125 MMF 200/500 MHz.kmOM2 - 50/125 MMF 500/500 MHz.km
SM2
Buffer type and no.of fi bres/buffer:
L - Loose multitubeC - Central tubeT - TightB - Break-out
L12
Design family:
D - DielectricM - Metallic
D
Waterblocking:
F - Filling Compound W - Waterblocking
W
Sheathconfi guratione.g. PKP,KP,EP,PEP,TKT,PSP8
P - PEK - Aramid yarnsE - Glass yarnsT - HFFRS - Steel corrugated8 - Figure 8G - Steel wire armouringU - PUD - PAC - Aramid woven tapeSx - SimplexDx - DuplexDxg - Duplex Shotgun
KPB3 CODE
TECHNOLOGIESFFFFFUUUUUTTTTTUUUUURRRRREEEEE
TM
THE NORDICSIndustrigatan 3731 36 KöpingSwedenEmail: [email protected]
ASIA2401A, 24/F. Park-In Commercial Centre No.56 Dundas Street Mongkok, Kowloon, Hong KongTel: +852 27100668Fax: +852 30119178Email: [email protected]
CHINAB3 Future Technologies Ltd3/F Sunsea Mansion, Hi Tech Park, HuanGuan Nan Road, GuanLan, Boa’an Dist., 518067 Shenzhen,ChinaChina Mobile: +86 18688165105Email: [email protected]
UNITED KINGDOMDelaunays Road, Blackley,Manchester, M9 8FPTel: +44 161 740 9151Fax: +44 161 741 2373Email: [email protected]
SPAIN and PORTUGALc/ Concha Espina s/n - 39600,Maliaño, CantabriaTel: +34 942250100Fax: +34 942269097Email: [email protected]
MIDDLE EASTPO Box 36605, Dubai,United Arab EmiratesTel: +971 42932550Fax: +971 42932525Email: [email protected]
GERMANY, AUSTRIA and SWITZERLANDRegensburger Straße 90 92318 Neumarkt GermanyTel: +49 9181 2650 470Fax: +49 9181 2650 469Email: [email protected]