COMPACT ELECTRIC DRIVEN GAS BOOSTERRATED UP TO 10,000-PSI (690 BAR)
Series 2G Electric Driven Booster package is ideal for filling or topping off low-pressure and high-pressure bottles. Its two-stage and double acting design uses NO Belts or Pulleys, making it the quietest Electric Driven Booster in its class; only 60 dBA. Air cooled thru its gas barrels inside cooling sleeves reducing the heat of compression for long seal life.
SERIES 2G
EGB100A
HYDRAUL ICS INTERNATIONAL, INC .CHATSWORTH, CAL IFORNIA
www.h i ig roup .com (818) 407-3400
SPECIFICATIONS: CONTROLS:
■ Adjustable High pressure Limit Switch pre-set to any pre-selected pressure up to 10,000-psi (690 bar) to automatically STOP the unit when the outlet pressure exceeds set point
■ Manual start & stop switch■ Safety relief Valve■ Inlet & outlet pressure gauges■ 6-digit hour meter■ Inlet & outlet 5-micron filters■ Cooling Fan
DIMENSIONS: 11.5” H x 22” D x 32” WWEIGHT: 145 Pounds (65.9 Kg)PORTS (INLET/OUTLET): 37º Flare 1/4”MAX. OUTLET PRESSURE: 10,000-PSI (690 BAR)MOTOR: 2-HP @ 1750 RPMLOW NOISE LEVEL: 60 dBAVOLTAGES: 115 VAC, 24 Amps, 1-Phase, 60 HZ 220 VAC, 12 Amps, 1-Phase, 60 HZ 230 VAC, 6.8 Amps, 3-Phase, 60 HZ 460 VAC, 3.4 Amps, 3-Phase. 60 HZ 380 VAC, 3.6 Amps, 3-Phase, 50 HZOPERATING SPEED: 45 cycles/minute (CPM) (Optional 72-CPM)
STANDARD
■ Remote start & stop switch with a 6-foot cord■ Automatic STOP low pressure limit switch■ Automatic STOP & RESTART low pressure limit switch■ Automatic STOP & RESTART high pressure Limit switch■ Two outlet pressure control settings■ Oxygen cleaned to MIL-STD 1330D■ Flow control inlet pressure regulator with full
pressure bypass line■ 4-port outlet manifold
OPTIONAL
Maximum Pressure PSI (Bar)MODEL 2G-Inlet Outlet
Minimum Gas Inlet Pressure-PSI (Bar)
Maximum Flow Rate-SCFM (NM3/MIN)
MODEL SELECTION TABLEMaximum Cycle
Rate (CPM)
TWO STAGE730750
1430145030505092
DOUBLE ACTING30305050
185 (13) 3500 (241) 30 (2) 2.20 (0.06) 72 105 (7) 6000 (414) 30 (2) 1.20 (0.034) 72 670 (46) 3500 (241) 60 (4) 4.00 (0.11) 72 375 (26) 6000 (414) 60 (4) 2.30 (0.07) 72 1900 (131) 6000 (414) 200 (14) 4.80 (0.14) 72 3380 (233) 10,000 (690) 300 (21) 5.40 (0.15) 72 3500 (241) 3500 (241) 200 (14) 16.00 (0.45) 72 6000 (414) 6000 (414) 200 (14) 18.00 (0.51) 72
COMPACT ELECTRIC DRIVEN GAS BOOSTERRATED UP TO 10,000-PSI (690 BAR)
Series 2G Electric Driven Booster package is ideal for filling or topping off low-pressure and high-pressure bottles. Its two-stage and double acting design uses NO Belts or Pulleys, making it the quietest Electric Driven Booster in its class; only 60 dBA. Air cooled thru its gas barrels inside cooling sleeves reducing the heat of compression for long seal life.
SERIES 2G
EGB101
HYDRAUL ICS INTERNATIONAL, INC .CHATSWORTH, CAL IFORNIA
www.h i ig roup .com (818) 407-3400
SPECIFICATIONS:
DIMENSIONS: 11.5” H x 22” D x 32” WWEIGHT: 145 Pounds (65.9 Kg)PORTS (INLET/OUTLET): 37º Flare 1/4”MAX. OUTLET PRESSURE: 10,000-PSI (690 BAR)MOTOR: 2-HP @ 1750 RPMLOW NOISE LEVEL: 60 dBAVOLTAGES: 115 VAC, 24 Amps, 1-Phase, 60 HZ 220 VAC, 12 Amps, 1-Phase, 60 HZ 230 VAC, 6.8 Amps, 3-Phase, 60 HZ 460 VAC, 3.4 Amps, 3-Phase. 60 HZ 380 VAC, 3.6 Amps, 3-Phase, 50 HZOPERATING SPEED: 45 cycles/minute (CPM) (Optional 72-CPM)
CONTROLS:
■ Adjustable High pressure Limit Switch pre-set to any pre-selected pressure up to 10,000-psi (690 bar) to automatically STOP the unit when the outlet pressure exceeds set point
■ Manual start & stop switch■ Safety relief Valve■ Inlet & outlet pressure gauges■ 6-digit hour meter■ Inlet & outlet 5-micron filters■ Cooling Fan
STANDARD
■ Remote start & stop switch with a 6-foot cord■ Automatic STOP low pressure limit switch■ Automatic STOP & RESTART low pressure limit switch■ Automatic STOP & RESTART high pressure Limit switch■ Two outlet pressure control settings■ Oxygen cleaned to MIL-STD 1330D■ Flow control inlet pressure regulator with full
pressure bypass line■ 4-port outlet manifold
OPTIONAL
MODEL SELECTION TABLE:
2G-07302G-3030
185 (13) 3500 (241) 30 (2) 5.01 (81.9) 3500 (241) 3500 (241) 300 (20.7) 2.37 (38.8)
Volume Displacement per Cycle- cu-in (ml)
Minimum Gas Inlet Pressure-PSI (Bar)
Maximum Pressure PSI (Bar)Inlet Outlet
Model
18
16
14
12
10
8
6
4
2
0 250 375 500 670 1000 1500 1900 2500 3000 1 1.5 2 2.7 4 6 7.6 10 12 1.6 2.4 3.2 4.3 6.4 9.6 12.1 16
2G-303012G-30302
69cpm
43 cpm
Flow Rate vs. cycle speed at 3500-psi outlet pressureMODEL 2G-3030
Inlet Gas Pressure - PSI
Out
let F
low
- SC
FM
4.5
4
3.5
3
2.5
2
1.5
1
0.5
0 30 60 90 160 185 250 375 500 0.27 0.4 0.67 0.83 1.12 1.7 2.24 3 0.43 0.65 1.12 1.33 1.8 2.7 3.6 4
2G-143012G-14302
69cpm
43 cpm
Flow Rate vs. cycle speed at 3500-psi outlet pressureMODEL 2G-1430
Inlet Gas Pressure - PSI
Out
let F
low
- SC
FM