23
Save Time and Energy with the Compact AnnubarFlowmeter Name Date

Compact Annubar Customer Presentation_Final.pdf

Embed Size (px)

Citation preview

  • Save Time and Energy with the Compact Annubar Flowmeter

    Name

    Date

  • Slide 4

    Rosemount Invented the Averaging Pitot Tube and Continues to Innovate

    Integral thermowell

    available Innovative upstream slot for

    comprehensive averaging

    T-shaped sensor creates large stagnation zones on

    backside to reduce noise

    1970 1978 1984 1998 2002

  • Slide 5

    Flow

    LOW HIGH

    Impact area

    DP(hw) = PH(avg.) - PL(avg.)

    Basic Principle of Annubar Primary Element

    Static

    Pressure

    Impact Pressure (40%)

    Blockage / Suction

    Pressure (60%)

    Total

    DP

    Velocity

    Profile

    (40/60 relationship not

    the same for all APTs)

  • Slide 6

    Key Messages

    The 405A Compact Annubar Flowmeters allow for unparalleled ease of installation

    The 405A Compact Annubar sensor provides accurate measurements while keeping energy costs low through reduced permanent pressure loss

    Standardize DP Flow Installations with the 405 Compact Platform

  • Slide 7

    Are Difficult Installations Slowing Down Projects?

    Impulse piping

    Welding and additional pipe penetrations

    Extra time = $$$, labor for a welder, instrument tech, etc

  • Slide 8

    How Much Does a Flowmeter Really Cost?

    Purchase Price Total Installed Cost

    Material Costs

    Price of Components

    Engineering Costs

    Select Technology

    Size

    Create Spec Sheets & Drawings

    Procurement Costs

    Generate Purchase Orders

    Manage Delivery Dates

    Vendor Relationships

    Installation Costs

    Piping Preparation

    Installation

    Commissioning

    Source: 4 Inch line size per Aspen Richardson Process Plant Construction Estimating Standards, 2003

    Edition, Process Equipment Cambridge: Aspen technology Inc., 2003.

    65%

    Installed Cost

    Traditional Installation

  • Slide 9

    405A Compact Flowmeters Eliminate Impulse Piping and Leak Points

    Installed using standard

    impulse lines

    Eliminates troublesome

    impulse lines, reducing

    fugitive emissions and

    improving reliability

    Traditional DP Flowmeter

    Assembly Installation

    Compact Flowmeter

    Installation

    Potential Leak Points = 29

    Potential Leak Points = 6

    Only 2 leak points to check in the field

    during installation!

    +

    +

    +

    Factory Leak Tested

    Reduce Leak

    Points by 80%

  • Slide 10

    405A Integrated Flowmeters Arrive Fully Assembled and Factory Leak Checked

    Eliminates Impulse Piping and

    Reduces Potential Leak Points

    All-Welded Design

    Provides Easy

    Transmitter Connection

    Direct Mount Manifold

    Easily Installs Between

    Raised Face Flanges

    405 Compact Design

    Ensures Proper

    Alignment within the Pipe

    Integral Centering Ring

    Decreases Measurement Error

    Annubar T-Shapes higher signal with less noise and frontal slot

    design

    Eliminate Additional Pipe

    Penetrations

    Integral RTD

    Lowers Permanent Pressure Loss

    Averaging Pitot Tube Technology

  • Slide 11

    .67 Beta Orifice with

    19-Tube Bundle

    Annubar Technology Reduces Straight Run Requirements

    1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44

    .67 Beta Orifice

    Rosemount

    Compact

    Annubar

    Elbow

    Mounted

    Annubar

  • Slide 12

    Are High Utility Costs Hurting Your Bottom Line?

    How much energy could you save?

    $$$

    The biggest issue is the surging cost of energy,

    which now makes up

    30% of operating

    costs for the average

    company. *Control Global

  • Slide 14

    The amount of pressure lost is a function of 3 factors:

    density of the fluid (f),

    velocity of the fluid (Vf)

    the amount obstruction (Kmeter) created by the flowmeter

    Sometimes Less is More When It Comes to PPL

    Note: The Kmeter factor for a technology is dependent on the model selected.

    The following is a guideline for Kmeter, in order from

    highest to lowest

    Orifice/

    Nozzle

    Venturi

    Averaging

    Pitot Tube

    Wedge

    V-Cone

    Turbine

    PPL = Kmeter x f x (Vf)2

  • Slide 16

    The 405A Allows You to Minimize Pressure Loss Throughout the Process

    Pressure at Source > Pressure at Destination

    Destination Source

    FT4

    Compressor

    PL1

    PL2

    PL3

    PL4

    PL5

    PL6

    PL7 Energy In

    Machine #1

    Machine #2

    Machine #3

    Machine #4

    FT6

    FT5

    FT7

    FT2

    FT1

    FT3

    Lowering Pressure Loss 1. Reduces pumping/compressing costs

    2. Increases capacity

    3. Minimizes compressor, pump or boiler size

  • Slide 17

    Annubar Technology Reduces PPL and Energy Costs

    Minimizing pumping and compression costs Increases throughput in existing lines Maximize capacity of gravity-fed systems

  • Slide 18

    Has Valuable Experience in your plant Gone Fishing?

    40% of the existing workforce will retire

    in the next 10

    years.

    *Society of Petroleum Engineers

    What will happen when your experienced

    personnel retire?

  • Slide 20

    Achieve a Perfect Installation Every Time for Every DP Flow Measurement Point

    Standardize installation procedures with the 405 Compact Platform

    Eliminate extra time, mis-installations, and training

    Conditioning

    Orifice

    Annubar

    Orifice

  • Slide 22

    Important 405A Specifications

    Accuracy

    1.5% of flow coefficient

    (0.75% Calibrated)

    Line Sizes

    2-8 (50-200 mm) Coming Soon! 10 & 12 (250 & 300mm)

    Repeatability

    0.1%

    Pressure Rating

    ANSI 600# or DIN PN100

  • Slide 23

    The Annubar T-Shape Creates a Higher Signal with Less Noise

  • Slide 24

    The Annubar T-Shape: No Wear, No Tear, No Worries

    No sharp leading

    edges to wear

    The Compact Annubar sensor

    provides better wear resistance than

    orifice plates

  • Slide 27

    405C/P

    0.40

    405 C/P

    0.65

    405A / 485

    Sensor Size 1

    10,000 lb/hr 4,500 kg/hr

    15,000- lb/hr

    6,750 kg/hr 20,000- lb/hr

    9,000 kg/hr 5,000 lb/hr 2,250 kg/hr

    2-in. H2O

    5-mbar

    100-in. H2O

    250-mbar

    2-in. H2O

    5-mbar

    2-in. H2O

    5-mbar

    100-in. H2O

    250-mbar

    100-in. H2O

    250-mbar

    150# Steam - 4 (100mm) line size, sized 100 H2O

    Utilize the 405A for Applications with Medium to High Flow Rates

  • Slide 28

    Annubar Products Reach Beyond Flanges Pak-Lok

    Patented compression design firmly secures the

    Annubar sensor to the

    opposite wall of the pipe

    Rated up to 600# ANSI

    Flange-Lok

    Combines Pak-Lok compression mechanism

    with a mounting flange

    Flanged With Opposite

    Side Support

    Meets the requirement of high pressure applications

    Available up to 2500# ANSI

    Flo-Tap

    Can be hot-tapped without interruption of the flow

    Easily removed for cleaning or line pigging

    Available up to 600# ANSI

  • Slide 29

    Better Measurement is the Key to Better Control

    3 in 1 measurement including differential pressure, static pressure, and temperature

    The result is better control of raw materials, combustion, reactions, blending and product quality

  • Slide 31

    Summary

    405A Compact Annubar products provide unparalleled ease of installation

    The 405A Compact Annubar sensor provides accurate measurements while keeping energy costs low through a low permanent pressure loss

    Standardize DP Flow Installations with the Compact 405 Platform

  • Thank you for your time and attention!