If you can't read please download the document
Upload
buihanh
View
217
Download
0
Embed Size (px)
Citation preview
CommunicationCablesFIBER OPTICS OPGW FTTH
2 _ Optical Cables
TAIHAN has served a pivotal role in establishing communication networks from backbone networks to
local loops both in Korea and major overseas markets. As demand of high capacity and high speed IT
expands recently, TAIHAN provides optimal communication environment where various information
can be delivered promptly and accurately based on our technology of producing high quality optical
fiber. TAIHAN will lead the ubiquitous environment with optimal solutions for communication infra from
backbone to FTTH network.
CONNECTING THE WORLD BY TAIHAN COMMUNICATION CABLES
ContentsFIBER OPTICS 4OPGW 34FTTH 38APPENDIX 54
Optical Cables _ 3
HISTORY OF TAIHAN COMMUNICATION CABLES
1955. Founded Taihan Electric Wire Co., Ltd. 1961. Produced the lead sheathed communication cable 1964. Acquired KS mark
for wire and cable 1965. Produced 1.2/4.4mm fine conductor coaxial cable 1968. Started production of stalpeth cable 1974.
Acquired UL and CSA certificate first time in Korea 1976. Produced standard coaxial cable 1978. Developed optical fiber cable
1979. Installed the optical cable networks in Seoul 1983. Produced foam skin communication cable first time in Korea 1984.
Completed optical fiber cable plant in Anyang / Produced multiple and single mode optical fiber cable 1985. Supplied the opti-
cal fiber cable for Seoul Olympic communication networks 1986. Acquired the KS Mark for high frequency coaxial cable / Won
the Prime Minister Award meritorious service in national backbone communication network 1987. Manufactured Optical Fiber
Ground Wire (OPGW) / Developed high foamed coaxial cable for CATV 1988. Developed submarine optical fiber cable and
leakage coaxial cable 1989. Developed optical fiber cable for emergency 1991. Supplied 565Mb/s optical transmission system
to KT 1993. Acquired ISO 9001 certificate on cable 1994. Developed 345kV OPGW 1996. Developed optical distribution board,
optical terminal box and 765kV OPGW 1997. Developed ribbon type optical fiber cable 1998. Commercialized the multiple
mechanical optical connector / Developed Non-Zero Dispersion Shifted optical fiber 2000. Acquired ISO 9001 certificate on
OPGW 2001. Acquired UL and KS certificate on Unshielded Twisted Pair (UTP) cable 2002. OPTOMAGIC, TAIHANs sub-
sidiary specialized in optical fiber completed optical fiber plant 2004. Developed FTTH total solution / Participated in BcN
(Broadband convergence Network) business (Ubinet consortium construction of FTTH) 2005. Developed Cat.7 Data Cable
2006. TAIHAN succeeded in developing holey fiber for the first time in Korea 2007. Developed Radiation High Foamed Coaxial
Cable (RCX) 42D cable
4 _ Optical Cables
Optical Cables _ 5
TAIHAN had led the development of optical fiber markets through continuous investment in technology and facility
since its first development in 1978. TAIHAN has produced optical fiber for VAD (Vapour - phase Axial Deposition)
method. TAIHAN has developed new products like zero water peak fiber for entire wavelength, NZ-DSF for 40Gbps
high-speed information, and bending loss insensitive fiber. With the development of holey fiber for FTTH in 2006, TAI-
HAN taking the lead in establishing the next generation IT network. Using such quality optical fiber, TAIHAN produce
and supply various kinds of optical cables for duct, aerial and direct buried.
FIBER OPTICS
ContentsOptical Fibers & CablesSMF ITU-T G.652.B 6ZWPF ITU-T G.652.D 8Bending Loss Insensitive Fiber ITU-T G.657 10NZ-DSF ITU-T G.655.C, G.656 12Tight Buffered Fiber 14Ribbon Fiber 16Loose Tube Cable for Duct 18Loose Tube Cable for Direct Buried 19Loose Tube Cable for Aerial (ADSS Type) 20Loose Tube Cable for Aerial (FIG 8 Type) 22Ribbon Slot Cable 23Ribbon Tube Cable 24Optical Micro Cable 25Loose Tube Cable for CATV Network 26High-count Loose Tube Cable (600-fiber) 27Submarine Optical Cable 28
Optical ApparatusFiber Optic Connectivity 29Optical Termination Cable 30Optical Multi Jumper Cable 31Optical Distribution Frame 32Fiber Optic Terminating Boxes 33Fiber Optic Cable Emergency Repairing Systems 34
6 _ Optical Fibers & Cables
Optical Fibers & Cables
SMF ITU-T G.652.B
Conspicuous lower attenuationSuperior bending performanceMechanically strippable coatingExcellent geometric properties for low splicing lossTransmission capacity at 1310 and 1550
Feature
Data communication cableFTTH network cableLong haul telecommunication cableCATV cable
Use / Application
Refractive Index Profile
Test Attenuation change @1550 (/)
Temperature cycling performance
Temperature humidity test
Water immersion
Heat aging
- 60 to + 85
+ 85, 98%, 30 days
+ 23, 30 days
+ 85, 30 days
0.05
0.05
0.05
0.05
Core_8
Cladding_125
UV acrylate coating_242
0.36%_Refractive
Index Profile
Structure
Environmental Characteristic
Single Mode Optical Fiber (VAD Process)TAIHANs single mode optical fiber is manufactured by the vapour - phase axial deposition (VAD) proecss to produce the highest quality glass with excellent geometry, high strength characteristics and attenuation levelthat approaches the theoretical minimum, and designed to operate at 1310 nm and 1550 nm. Its optical prop-erties are achieved through a germanium doped silica core with a pure silica cladding. A dual acrylate pro-tective coating is applied over glass to provide the maximum fiber lifetime.
Optical Fibers & Cables _ 7
Spectral Attenuation Weibull Parameter
0.35 / ( 0.334 / for fiber)
0.21 / ( 0.194 / for fiber)
0.5 /
0.05 / (1310 )
0.05 / (1550 )
0.03 / (Max - Min)
0.05
1300 ~ 1322
0.092 ps/( 2. )
3.5 ps/( . )
18 ps/( . )
1260
0.15 ps/
0.1 ps/
Fiber length
Spool dimension Flange diameter Nom.
Barrel diameter Nom.
Inner width Nom.
Outer width Nom.
Bore diameter Nom.
25.2 / 50.4
234.5 / 265
152.0 / 170
96.0 / 150
116.0 / 175
25.4 / 25.4
Packaging
Attenuation at 1310
at 1550
at 1383 3
Attenuation change at 1285 ~ 1330
at 1525 ~ 1575
at 1575 ~ 1610
Point discontinuity at 1310 and 1550
Zero dispersion wavelength
Zero dispersion slope
Chromatic dispersion at 1285 ~ 1330
at 1550
Cable cut-off wavelength
PMD for individual value (uncabled fiber)
for link value
Optical Characteristic
Performance Specification
Performance Characteristic
Mode field diameter
Cladding diameter
Core/cladding concentricity error
Cladding non-circularity
Fiber curl radius
Primary coating diameter (For uncolored fiber)
Primary coating diameter (For colored fiber)
Coating/cladding concentricity error
Fiber proof test level
9.2 0.4 at 1310
10.4 0.5 at 1550
125.0 0.7
0.5
0.7%
4 m
242 5
250 10
12
120 kpsi (1.2 % strain)
Geometrical Characteristic
8 _ Optical Fibers & Cables
Optical Fibers & Cables
ZWPF ITU-T G.652.D
Conspicuous lower attenuationSuperior bending performanceMechanically strippable coatingExcellent geometric properties for low splicing lossTransmission capacity at 1285 nm to 1625 nm
Feature
Data communication cableFTTH network cableLong haul telecommunication CATV cableLong term reliability for attenuation
Use / Application
Refractive Index Profile
Core_8
Cladding_125
UV acrylate coating_242
0.36%_Refractive
Index Profile
Structure
Zero Water Peak Single Mode Fiber (VAD Process)TAIHAN's Anywave single mode fiber (Zero water peak fiber) is manufactured by the vapour - phase axialdeposition (VAD) process to produce the highest quality glass with excellent geometry and high strengthcharacteristics. Anywave can be used in all wavelength from 1280 nm to 1620 nm because OH ion is per-fectly eliminated in specially designed manufacturing process. Anywave is reliable for any wavelengthdivision. Anywave enables customers to construct high performance network for data transmission in WDMsystem.
Test Attenuation change @1550 (/)
Temperature cycling performance
Temperature humidity test
Water immersion
Heat aging
- 60 to + 85
+ 85, 98%, 30 days
+ 23, 30 days
+ 85, 30 days
0.05
0.05
0.05
0.05
Environmental Characteristic
Optical Fibers & Cables _ 9
Spectral Attenuation
Performance Specification
Weibull Parameter
Performance Characteristic
Mode field diameter
Cladding diameter
Core/cladding concentricity error
Cladding non-circularity
Fiber curl radius
Primary coating diameter (For uncolored fiber)
Primary coating diameter (For colored fiber)
Coating/cladding concentricity error
Fiber proof test level
9.2 0.4 at 1310
10.4 0.5 at 1550
125.0 0.7
0.5
0.7%
4 m
242 5
250 10
12
120 kpsi (1.2 % strain)
0.35 / ( 0.334 / for fiber)
0.21 / ( 0.194 / for fiber)
0.31 / (after H2aging)
0.05 / (1310 )
0.05 / (1550 )
0.03 / (Max - Min)
0.05
1300 ~ 1322
0.092 ps/( 2. )
3.5 ps/( . )
18 ps/( . )
22 ps/( . )
1260
0.15 ps/
0.1 ps/
Geometrical Characteristic
Fiber length
Spool dimension Flange diameter Nom.
Barrel diameter Nom.
Inner width Nom.
Outer width Nom.
Bore diameter Nom.
25.2 / 50.4
234.5 / 265
152.0 / 170
96.0 / 150
116.0 / 175
25.4 / 25.4
Packaging
Attenuation at 1310
at 1550
at 1383 3
Attenuation change at 1285 ~ 1330
at 1525 ~ 1575
at 1575 ~ 1610
Point discontinuity at 1310 and 1550
Zero dispersion wavelength
Zero dispersion slope
Chromatic dispersion at 1285 ~ 1330
at 1550
at 1625
Cable cut-off wavelength
PMD for individual value (uncabled fiber)
for link value
Optical Characteristic
10 _ Optical Fibers & Cables
Optical Fibers & Cables
Bending Loss Insensitive Fiber ITU-T G.657. A & B
Fully compliant with ITU-T G.652.D & G.657. A & BAllowable bending diameter : 20 1/3 Bending diameter compared to conventional SMF(60 )Good splicing with conventional SMF and ZWPF
Feature
Fully compatibility with conventional SMFMinimized construction spaceFTTH / Premise/LAN cablesAir blown fiberOptical cord
Use / Application
Refractive Index Profile
Test Attenuation change @1550 (/)
Temperature cycling performance
Temperature humidity test
Water immersion
Heat aging
- 60 to + 85
+ 85, 98%, 30 days
+ 23, 30 days
+ 85, 30 days
0.05
0.05
0.05
0.05
Core_7.5
Cladding_125
UV acrylate coating_242
0.44%_Refractive
Index Profile
Structure
Environmental Characteristice
Bending Loss Insensitive Fiber ITU-T G.657 (VAD Process)TAIHAN's bending loss insensitive fiber (Strong Bend) manufactured by the vapour - phase axial deposition(VAD) process enables the use of the entire optical fiber spectrum (1280 nm~1625 ) including 1360nm~1460 due to a manufacturing process that virtually eliminates hydroxy (OH-) absorption in the fiber.It's low sensitivity to macrobending results in lower attenuation levels in the 1550 and 1625 wave-length region.
Optical Fibers & Cables _ 11
Performance Specification
0.35 / ( 0.34 / for fiber)
0.22 / ( 0.20 / for fiber)
0.24 / ( 0.23 / for fiber)
0.31 / (after H2aging)
0.05 / (1310 )
0.05 / (1550 )
0.03 / (Max - Min)
0.05
1300 ~ 1322
0.092 ps/( 2. )
3.0 ps/( . )
18 ps/( . )
1260
0.15 ps/
0.1 ps/
Fiber length
Spool dimension Flange diameter Nom.
Barrel diameter Nom.
Inner width Nom.
Outer width Nom.
Bore diameter Nom.
6.3 ~ 25.2 in multiples of 2.1
234. 5
152.0
96.0
116.0
25.4
Packaging
Macrobending loss
for 100 turns at a 50 mandrel diameter
for single bend (20 diameter one turm)
Coating strip force
0.05 @ 1625
0.15 @ 1625
1.3 ~ 8.9 N
Mechanical Characteristic
Attenuation at 1310
at 1550
at 1625
at 1383 3
Attenuation change at 1285 ~ 1330
at 1525 ~ 1575
at 1575 ~ 1610
Point discontinuity at 1310 and 1550
Zero dispersion wavelength
Zero dispersion slope
Chromatic dispersion at 1285 ~ 1330
at 1550
Cable cut-off wavelength
PMD for individual value (uncabled fiber)
for link value
Optical Characteristic
Performance Characteristic
Mode field diameter
Cladding diameter
Core/cladding concentricity error
Cladding non-circularity
Fiber curl radius
Primary coating diameter (For uncolored fiber)
Primary coating diameter (For colored fiber)
Fiber proof test level
8.6 0.4 at 1310
125.0 0.7
0.5
0.7%
4 m
242 5
250 10
120 kpsi (1.2 % strain)
Geometrical Characteristic
12 _ Optical Fibers & Cables
Optical Fibers & Cables
NZ-DSF ITU-T G.655, G.656
Optimatized for effective operating of WDM system10Gbps, 40Gbps, and higher data ratesSuperior performance for long haul networksLower sensitivity of transmission propertiesBroad - range low attenuation properties
Feature
Submarine cablesVoice, video and data transmissionLong haul WDM systemLong distance applications
Use / Application
Core_6
Cladding_125
UV acrylate coating_242
0.36%_Refractive
Index Profile
Structure
Non-Zero Dispersion Shifted Optical Fiber (VAD Process)TAIHAN's non-zero dispersion shifted single mode fiber (NZF) is operated for WDM system, which enablescustomers to construct high performance networks for voice, video and/or data transmission. its high perfor-mances are achieved through a germanium doped double silica cladding made by the vapour - phase axialdeposition (VAD) method. A dual layer acrylate is coated over the cladding to provide high product reliabilityand allows easy splicing throughout the cable life. The fiber operates in C-band, L-band and S-band.
Refractive Index Profile
Test Attenuation change @1550 (/)
Temperature cycling performance
Temperature humidity test
Water immersion
Heat aging
- 60 to + 85
+ 85, 98%, 30 days
+ 23, 30 days
+ 85, 30 days
0.05
0.05
0.05
0.05
Environmental Characteristic
Optical Fibers & Cables _ 13
Chromatic Dispersion
Performance Specification
Weibull Parameter
Performance Characteristic
ITU-T G.655.A ITU-T G.655.C, 656
Mode field diameter
Cladding diameter
Core/cladding concentricity error
Cladding non-circularity
Fiber curl radius
Primary coating diameter (For uncolored fiber)
Primary coating diameter (For colored fiber)
Coating/cladding concentricity error
Fiber proof test level
8.2 0.5 at 1550
125.00.7
0.5
0.7 %
4 m
242 5
250 10
12
120 kpsi
9.2 0.5 at 1550
125.00.7
0.5
0.7%
4 m
242 5
250 10
12
120 kpsi
0.22 /
0.25 /
0.10
2.0 ~ 6.0 ps/ ( , )
4.0 ~ 1.0 ps/ ( , )
1300
0.15 ps/
0.1 ps/
Geometrical Characteristic
Fiber length
Spool dimension Flange diameter Nom.
Barrel diameter Nom.
Inner width Nom.
Outer width Nom.
Bore diameter Nom.
25.2
234.5
152.0
96.0
116.0
25.4
Packaging
Attenuation at 1550
at 1625
Point discontinuity at 1550
Chromatic dispersion at 1530 ~ 1565 nm
at 1560 ~ 1625 nm
Cable cut-off wavelength (cc)
PMD for individual value (uncabled fiber)
for link value
Optical Characteristic
0.22 /
0.25 /
0.10
5.5 ~ 10ps/ ( , )
7.5 ~ 13.5ps/ ( , )
1450
0.15 ps/
0.1 ps/
14 _ Optical Fibers & Cables
Optical Fibers & Cables
Tight Buffered Fiber
12 Color codingAvailable in single mode and multi-mode fibersHighly flexible and light weight for easy handlingEasy strippig for quick splicingVarious coating material availableDiameter up to 900
Feature
Performance Specification
Easy identification for improved cable management in routing and terminationNon-conductive designFlame-retardant designInter-equipment connections that are indoors or in controlled environmentsComputer data links, terminal links, inter-frame, internal connections
500 ( 0.50 )
or
900 ( 0.90 )
UV-Acrylate
or
UV-Silicon
Use / Application
Tight Buffered FiberTAIHAN's tight buffered optical fiber is used in inter-equipment, fiber optic transmission system requiringfiber optic cable. Tight buffered fiber is color coded for easy identification allowing improved cable man-agement in routing and termination in indoor cable applications. It is suitable for use in computer datalinks, terminal links, inter-frame, and internal connections.
Fiber types
Buffered Construction Standard Diameter Tight Buffer Material
Maximum attenuation(/)
Typical attenuation(/)
SMF (9/125) (single mode fiber)
1310 / 1550
MMF (50/125) (multi- mode fiber)
850 / 1300
MMF (62.5/125) (multi- mode fiber)
850 / 1300
0.4 / 0.25
3.0 / 1.0
3.0 / 1.0
0.35 / 0.20
2.5 / 0.5
2.7 / 0.6
Cabled Attenuation
Buffered Dimension & Materials
Core
Cladding
UV acrylate coating
Tight buffer
Optical Fibers & Cables _ 15
Ordering information
9 / 125 SMF (single mode fiber)
50 / 125 MMF (multi-mode fiber)
62.5 / 125 MMF (multi-mode fiber)
1. Select Fiber Type
UV-acrylate
UV-silicon
2. Select Buffer Materials
500 Buffer diameter
900 Buffer diameter
3. Select Inner Jacket Materials
16 _ Optical Fibers & Cables
Optical Fibers & Cables
Ribbon Optical Fiber
Small diameter cable by high density fiberPrecise fiber geometryEasily accessible individual fibersReduce the installation cost by easy handling and low weight
Feature
Dimension
Easy handling, installation and shippingInstallation costs and cable weightAvailable for distribution of dense metropolitan area
Use / Application
4 Fiber
Construction
Ribbon Optical FiberTAIHAN's ribbon optical fiber is available in standard counts of 4,8,12 fibers to meet a wide variety ofapplications. Ribbon fiber is used in applications requiring high communication rate and high fiber densityin small area. Also ribbon fiber offers precise fiber geometries for mass precision splicing and multi-fiberarray. Its high performance is achieved through a germanium doped double silica cladding produced bythe vapour - phase axial deposition (VAD) method.
unit_
8 Fiber
12 Fiber
Fig 1 : Cross-Section of 4-12 optical fiber ribbon
Refractive Index ProfileTest Attenuation change @1550
Temperature cycling test (TIA / EIA 455-3)
Temperature humidity test (+ 85, 98%, 30 days)
Water immersion(+23, 14 days)
0.05 / (-40 to +70)
0.1 /
0.1 / (+23)
Environmental Characteristice
Fiber countWidth(W)
Typical Max.Height(h)
Typical Max.
Planarity(p)
310 20
310 20
310 20
1100
2150
3150
1150
2200
3200
25
30
35
15
20
25
4
8
12
Optical Fibers & Cables _ 17
Performance Specification
0.35 /
0.22 /
0.30 /
0.05 / (1310 )
0.05 / (1550 )
0.03 / (Max - Min)
0.05
1300 ~ 1322
0.092 ps/( 2. )
3.5 ps/( . )
18 ps/( . )
22 ps/( . )
1260
0.15 ps/
0.1 ps/
Mode field diameter
Cladding diameter
Core/cladding concentricity error
Cladding non-circularity
Primary coating diameter (For uncolored fiber)
Primary coating diameter (For colored fiber)
Coating/cladding concentricity error
Fiber proof test level
9.2 0.4 at 1310
10.4 0.5 at 1550
125.0 0.7
0.5
0.7%
242 5
250 10
12
120 kpsi (1.2% strain)
Geometrical Characteristic
5.1 Delivery length of each ribbon bobbin shall be in multiples of 2 . Maximum lenght
shall be changed upon special agreement to within the maximum take-up
length specified in Table. 1
5.2 Dimensions of ribbon bobbin are specified in Table. 1.
5.3 Ribbon bobbin shall be packaged with anti-moisyure, anti-vibration and anti-shock
to maintain the ribbons performance.
Packaging
Attenuation at 1310
at 1550
at 1383
Attenuation change at 1285 ~ 1330
at 1525 ~ 1575
at 1575 ~ 1610
Point discontinuity at 1310 and 1550
zero dispersion wavelength
zero dispersion slope
Chromatic dispersion at 1285 ~ 1330
at 1550
at 1625
Cable cut-off wavelength
PMD for individual value (uncabled fiber)
for link value
Optical Characteristic
8
25
Fully peelable
Residual twist (TIA / EIA-455-131)
Strippability (Bellcore GR-20)
Peelability (Bellcore GR-20)
Mechanical Characteristic
Type
A
B
410
410
310
310
170
390
102
322
12
35
25.5 or 50.9
25.5 or 50.9
FlangeDiameter
Barrel Diameter
Outside Width Inside Width Axial hole Diameter
Maximum Take-up Length
Maximum Take-up Length is based on 4 optical fiber ribbon
18 _ Optical Fibers & Cables
Optical fiber Single mode optical fiber (SMF), multi mode optical fiber (MMF), non-zero dispersion shifted optical fiber (NZ-DSF)
Central strength member Galvanized steel wire or fiber reinforced plastic (FRP) Moisture barrier 1 Water blocking jelly filling compound or water blocking yarn Loose tube Thermoplastic material (polybutylene terephthalate) Filler Polyethylene string Wrapping tape Non-hygroscopic plastic tape or water blocking tape (optional) Moisture barrier 2 Laminated aluminum tape (optional) Sheath Black polyethylene Non-metal strength member Glass yarn or aramid yarn
Construction
Dry Type Jelly Type
Optical Fibers & Cables
Loose Tube Cable for Duct
Standard fiber count : 2~312 fibers Excellent optical performanceExcellent mechanical and environmental performance High tensile strength designAnti-termite treatment (optional) Dry or jelly filled type
Feature
Local area network (LAN) Subscriber network system Long haul communication system
Application
Cable Specification
Dry type
Outer dia.() Cable wt.(/)
Jelly filled type
Outer dia.() Cable wt.(/)
Mechanical & Environmental Characteristic
Allowable tensile strength
Crush resistance
Minimum bending diameter
Operating temperature range
Delivery length
Characteristic UnitDry type
135~450 180~550
20
20 times of cable diameter
10 times of cable diameter
-40 +70
1 6
Jelly filled type
Dynamic
Static
f
f/
Specification
2~36
48~72
7496
98120
122~144
288
312
10.5
11.1
12.5
13.9
15.5
18.2
19.0
90
102
130
158
195
253
276
10.9
11.5
12.8
14.2
15.8
18.5
19.3
122
136
142
174
214
341
374
No. of fibersNo. of fibers per tube
6
12
Optical Fibers & Cables _ 19
Optical fiber Single mode optical fiber (SMF), multi mode optical fiber (MMF), non-zero dispersion shifted optical fiber (NZ-DSF)
Central strength member Galvanized steel wire or fiber reinforced plastic (FRP) Moisture barrier 1 Water blocking jelly filling compound or water blocking yarn Loose tube Thermoplastic material (polybutylene terephthalate) Filler Polyethylene string Wrapping tape Non-hygroscopic plastic tape or water blocking tape Moisture barrier 2 Laminated aluminum tape (optional) Inner sheath Black polyethylene Armored layer Copolymer coated steel tape (steel tape armored) or steel wire armored Outer sheath Black polyethylene
Construction
Steel tape armored Steel wire armored
Optical Fibers & Cables
Loose Tube Cable for Direct Buried
Standard fiber count : 2~312 fibers Excellent optical performanceExcellent mechanical and environmental performance High tensile strength designAnti-termite and anti-rodent treatment (optional) Dry or jelly filled type
Feature
Local area network (LAN) Subscriber network system Long haul communication system
Application
Cable Specification
No. of fibers per tube No. of fibers
Steel tape armored
Outer dia.() Cable wt.(/)
Steel wire armored
Outer dia.() Cable wt.(/)
Mechanical & Environmental Characteristic
Allowable tensile strength
Crush resistance
Minimum bending diameter
Operating temperature range
Delivery length
Characteristic UnitSteel tape armored
200~500 500~2000
40
20 times of cable diameter
10 times of cable diameter
-40 +70
1 6
Steel wire armored
Dynamic
Static
f
f/
Specification
2~36
48~72
74~96
98~120
122~144
288
312
14.6
15.2
16.6
18.2
19.8
21.6
22.4
200
217
250
295
344
406
436
15.9
16.5
17.9
19.5
21.1
23.0
23.8
419
451
508
584
666
770
816
6
12
20 _ Optical Fibers & Cables
Optical fiber Single mode optical fiber (SMF), multi mode optical fiber (MMF), non-zero dispersion shifted optical fiber (NZ-DSF)
Central strength member Galvanized steel wire or fiber reinforced plastic (FRP) ADSS type : FRP Moisture barrier Water blocking jelly filling compound or water blocking yarn Loose tube Thermoplastic material (polybutylene terephthalate) Filler Polyethylene string Wrapping tape Non-hygroscopic plastic tape or water blocking tape Inner sheath Black polyethylene Armored layer Aramid yarn (Lashing aerial type: steel tape) Outer sheath Black polyethylene
Construction
Optical Fibers & Cables
Loose Tube Cable for Aerial (ADSS Type)
Standard fiber count :2~144 fibers Protection from lighting and electrical interferenceExcellent mechanical and environmental performance Dry or jelly filled type
Feature
Local area network (LAN) Subscriber network system Long haul communication systemPower line operating system
Application
Cable Specification
6
12
No. of fibers per tube No. of fibers
Outer dia.() Cable wt.(/)
2~30
36~72
7496
98120
122~144
15.0
16.0
17.5
19.2
21.0
160
180
230
275
330
Mechanical & Environmental Characteristic
Allowable tensile strength
Crush resistance
Minimum bending diameter
Operating temperature range
Delivery length
Characteristic Unit
200~800
20
20 times of cable diameter
10 times of cable diameter
-40 +70
1 6
Dynamic
Static
f
f/
Specification
Optical Fibers & Cables _ 21
Cable Specification
6
12
No. of fibers per tube No. of fibers
Outer dia.() Cable wt.(/)
2~30
36~60
6272
7496
98~120
122~144
11.7
12.3
12.5
14.0
15.6
17.2
100
110
115
145
180
215
Mechanical & Environmental Characteristic
Allowable tensile strength
Crush resistance
Minimum bending diameter
Operating temperature range
Delivery length
Characteristic Unit
150~600
20
20 times of cable diameter
10 times of cable diameter
-40 +70
1 6
Dynamic
Static
f
f/
Specification
Optical Fibers & Cables
Loose Tube Cable for Aerial (ADSS Type)
Standard fiber count :2~144 fibers Protection from lighting and electrical interferenceExcellent mechanical and environmental performance Dry or jelly filled type
Feature
Small diameter and light weight Subscriber network system Long haul communication systemPower line operating system
Application
Optical fiber Single mode optical fiber (SMF), multi mode optical fiber (MMF), non-zero dispersion shifted optical fiber (NZ-DSF)
Central strength member Galvanized steel wire or fiber reinforced plastic (FRP) ADSS type : FRP Moisture barrier Water blocking jelly filling compound or water blocking yarn Loose tube Thermoplastic material (polybutylene terephthalate) Filler Polyethylene string Wrapping tape Non-hygroscopic plastic tape or water blocking tape Armored layer Aramid yarn (Lashing aerial type: steel tape) Outer sheath Black polyethylene
Construction
22 _ Optical Fibers & Cables
Optical Fibers & Cables
Loose Tube Cable for Aerial (Fig 8 Type)
Standard fiber count : 2~144 fibers Excellent mechanical and environmental performanceDry or jelly filled type
Feature
Local area network (LAN) Subscriber network system Long haul communication system
Application
Cable Specification
6
12
No. of fibers per tube No. of fibers
Outer dia.() Cable wt.(/)
2~36
48~72
7496
98120
122~144
Mechanical & Environmental Characteristic
Allowable tensile strength
Crush resistance
Minimum bending diameter
Operating temperature range
Delivery length
Characteristic Unit
500~1500
30
20 times of cable diameter
10 times of cable diameter
-40 +70
1 4
Dynamic
Static
f
f/
Specification
Optical fiber Single mode optical fiber (SMF), multi mode optical fiber (MMF), non-zero dispersion shifted optical fiber (NZ-DSF)
Central strength member Galvanized steel wire or fiber reinforced plastic (FRP) ADSS type - FRP Moisture barrier 1 A water blocking jelly filling compound or water blocking yarn Loose tube Thermoplastic material (polybutylene terephthalate) Filler Polyethylene string Wrapping tape Non-hygroscopic plastic tape or water blocking tape Moisture barrier 2 Laminated aluminum tape Inner sheath Black polyethylene Armored layer Copolymer coated steel tape Outer sheath Black polyethylene Suspension wire Galvanized steel wire (7/2.0 mm, 7/1.6 mm, 7/1.2 mm, 7/1.0 mm steel wire)
Construction
14.6 / 25.6
15.2 / 26.2
16.6 / 27.6
18.2 / 29.2
19.8 / 30.8
418
433
467
511
560
Optical Fibers & Cables _ 23
Ribbon 2, 4, 8-fiber ribbon Central strength member Galvanized steel wire or fiber reinforced plastic (FRP) Slot Polyethylene slot Filler Polyethylene resin Wrapping tape Water blocking tape Moisture barrier Laminated aluminum tape Outer sheath Black color polyethylene
Construction
Single slot Multi slot
Cable Specification
Item UnitSingle slot Multi slot
Duct
No. of fiber
Slot dia.
No. of slot
Cable dia.
Cable weight
600
20
1
25
580
1152
11.8
6
43
1350
Mechanical & Environmental Characteristic
Allowable tensile strength
Crush resistance
Minimum bending diameter
Operating temperature range
Characteristic Unit
40
20 times of cable diameter
40 times of cable diameter
-40 +70
800 1300
Dynamic
Static
Specification
Single slot Multi slot
Optical Fibers & Cables
Optical Fiber Ribbon Slot Cable
Standard fiber count : 2~over 1152 fibers Excellent optical performanceExcellent mechanical and environmental performance Excellent branch and joint performanceLarge fiber count with small cable outer diameter
Feature
Local area network (LAN) Subscriber network system Long haul communication system
Application
fiber
ea
/
f
f/
24 _ Optical Fibers & Cables
Optical Fibers & Cables
Optical Fiber Ribbon Tube Cable
Standard fiber count : 144~over 864 fibers Excellent optical performanceExcellent mechanical and environmental performance Excellent branch and joint performanceLarge fiber count with small cable outer diameter
Feature
Local area network (LAN) Subscriber network system Long haul communication system
Application
Ribbon 4, 8, 12-fiber ribbon Loose tube Thermoplastic material (Polybutylene terephthalate) Filling compound Water blocking jelly compound Central strength member Galvanized steel wire or fiber reinforced plastic (FRP) Wrapping tape Water blocking tape Moisture barrier Laminated aluminum tape or steel tape (optional) Outer sheath Black color polyethylene Filler Polyethylene string
Construction
Cable Specification
Item UnitSingle tube Multi tube
Duct
Mechanical & Environmental Characteristic
Allowable tensile strength
Crush resistance
Minimum bending diameter
Operating temperature range
Characteristic Unit
40
20 times of cable diameter
40 times of cable diameter
-40 +70
270 600
Dynamic
Static
f
f/
Specification
Single slot Multi slot
Single tube Multi tube
No. of fiber
No. of tube
Cable dia.
Cable weight
fiber
ea
/
216
1
17.0
260
864
6
29.0
800
Optical Fibers & Cables _ 25
Optical fiber Single mode optical fiber (SMF), multi mode optical fiber (MMF), non-zero dispersion shifted optical fiber (NZ-DSF)
Central strength member Fiber reinforced plastic (FRP) Moisture barrier Water blocking yarn Loose tube Thermoplastic material (polybutylene terephthalate) Filler Polyethylene string Non-metal strength member Glass yarn or aramid yarn Sheath Black polyethylene
Construction
Cable Specification
6
12
No. of fibers per tube No. of fibers
Outer dia.() Cable wt.(/)
43
45
Mechanical & Environmental Characteristic
Allowable tensile strength
Crush resistance
Minimum bending diameter
Operating temperature range
Delivery length
Characteristic Unit
100
5
20 times of cable diameter
10 times of cable diameter
-40 +70
1 6
Dynamic
Static
f
f/
Specification
Optical Fibers & Cables
Optical Micro Cable
Standard fiber count : 2~60 fibers Excellent optical performanceExcellent mechanical and environmental performance Dry or jelly filled typeSmall diameter and light weight
Feature
Local area network (LAN) Subscriber network system Fiber to the home (FTTH)
Application
8.0
8.0
6~30
32~60
Optical fiber Single mode optical fiber (SMF), multi mode optical fiber (MMF), non-zero dispersion shifted optical fiber (NZ-DSF)
Central strength member Fiber reinforced plastic (FRP) Moisture barrier 1 Water blocking jelly filling compound or water blocking yarn Loose tube Thermoplastic material (polybutylene terephthalate) Filler Polyethylene string Wrapping tape Non-hygroscopic plastic tape or water blocking tape Moisture barrier 2 Laminated aluminum tape (optional) Inner sheath Black polyethylene Armored layer Copolymer coated steel tape or tin coated steel tape Outer sheath Black polyethylene
Construction
26 _ Optical Fibers & Cables
Single jacket Double jacket
Optical Fibers & Cables
Loose Tube Cable for CATV Network
Standard fiber count : 2~288 fibers Excellent optical performanceExcellent mechanical and environmental performance High tensile strength designAnti-rodent treatment Dry or jelly filled type
Feature
CATV system networkLocal area network (LAN)Subscriber network systemLong haul communication system
Application
Cable Specification
11.9
13.1
14.6
16.4
18.0
20.5
13.9
15.1
16.6
18.3
20.0
22.5
150
185
230
280
360
450
6
12
No. of fibers per tube No. of fibers
Single jacket
Outer dia.() Cable wt.(/)
Double jacket
Outer dia.() Cable wt.(/)
205
240
295
365
420
530
2 ~ 36
48 ~ 72
74 ~ 96
98 ~ 120
122 ~ 144
288
Mechanical & Environmental Characteristic
Allowable tensile strength
Crush resistance
Minimum bending diameter
Operating temperature range
Delivery length
Characteristic UnitSingle jacket
200~350 200~500
20 40
20 times of cable diameter
10 times of cable diameter
-40 +70
1 6
Double jacket
Dynamic
Static
f
f/
Specification
Optical Fibers & Cables _ 27
Optical Fibers & Cables
High-count Loose Tube Cable (600-fiber)
High density fiber counts for loose tube core up to 600 fibersExcellent optical performance Excellent mechanical and environmental performance
Feature
Local area network (LAN) Subscriber network system Long haul communication system
Application
Optical fiber Single mode optical fiber (SMF), multi mode optical fiber (MMF), non-zero dispersion shifted optical fiber (NZ-DSF)
Central strength member Galvanized steel wire or fiber reinforced plastic (FRP) Filling compound Water blocking jelly filling compound Loose tube Thermoplastic material (polybutylene terephthalate) Filler Polyethylene string Wrapping tape Non-hygroscopic plastic tape or water blocking tape Moisture barrier Laminated aluminum tape Inner sheath Black polyethylene Armored layer A corrugated steel tape Outer sheath Black polyethylene
Construction
Cable Specification
No. of fibers per tube Unit
Specification (60-fiber)
No. of tubes
No. of fibers per tube
Cable diameter
Cable weight
EA
EA
ton/
60
10
47
2.9 (including drum)
Mechanical & Environmental Characteristic
Allowable tensile strength
Crush resistance
Minimum bending diameter
Operating temperature range
Delivery length
Characteristic Unit
800
30
20 times of cable diameter
10 times of cable diameter
-40 +70
1 2
Dynamic
Static
f
f/
Specification
Optical fiber Single mode optical fiber (SMF), multi mode optical fiber (MMF), non-zero dispersion shifted optical fiber (NZ-DSF)
Central strength member Galvanized steel wire or Fiber reinforced plastic (FRP) Filling compound Water blocking jelly filling compound Loose tube Thermoplastic material (polybutylene terephthalate) Filler Polyethylene string Wrapping tape Non-hygroscopic plastic tape or water blocking tape Moisture barrier Laminated aluminum tape Inner sheath Black polyethylene Wrapped paper Non-woven tape Lead sheath Lead Outer sheath Black polyethylene Bedding layer Jute+Asphalt Wire armoring Galvanized steel wire Serving layer Jute+Asphalt+CaCo3 layer
Construction
28 _ Optical Fibers & Cables
Single armoring type Double armoring type
Optical Fibers & Cables
Submarine Optical Cable
Standard fiber count : 2 ~ 72 fibers High tensile strength designOptimized design for underwater application Excellent mechanical and environmental performance
Feature
High speed long haul communication system in lakes and rivers
Application
Mechanical & Environmental Characteristic
Allowable tensile strength
Crush resistance
Minimum bending diameter
Operating temperature range
Delivery length
Characteristic Unit Single Double
3500 5000
500 1000
20 times of cable diameter
10 times of cable diameter
-30 +70
`1~10
Dynamic
Static
f
f/
Cable Specification
ton/
-
Outer diameter
Cable weight
Steel structure
36.5
3.49
2.634 EAFirst : 2.633 EA
Second : 4.526 EA
49.7
7.22
Unit Single DoubleItem
Optical Apparatus _ 29
Optical Apparatus
Fiber Optic Connectivity
Convenient handling
Excellent cohesion efficiency
Able to attach various connectors
Feature
Optical Fiber Patch Cord (OPC)
Long-range optical transmission network
Optical subscriber network
Optical CATV network
Optical LAN system
Application
Convenient handlingExcellent cohesion efficiencyAble to attach various connectors Excellent geometric properties
Feature
Optical Fiber Fixed Attenuator (OFFA)
Optical CATV network Optical subscriber network Long-range optical transmission network
Application
ReusableImplemented low insertion loss and high reflection loss Easy installation for first time users Quick installation time (Access within 30 seconds)Bonding material and electricity is not needed
Feature
Mechanical Splices for Optical Fiber (MS)
Optical subscriber networkOptical CATV network
Optical LAN systemEmergence restoration
Application
Excellent function of reinforcing the optical fibers fusion connector
Multi environmental specificationHigh reliability
Feature
Optical Fiber Protection Sleeve (OFPS)
Optical subscriber network Optical CATV networkOptical LAN system
Application
30 _ Optical Apparatus
Optical Apparatus
Optical Termination Cable
Feature
Long-range optical transmission network Optical CATV network Optical subscriber network
Low connection loss Additional access is not needed Diverse acceptability
Application
Applied Specification
Cable form : Loose tube, Ribbon slot or tube, Tight boundNo. of Cores : Loose tube type - maximum 312
Ribbon type - maximum 320 Tight bound type - maximum 72
Applied connector (Abrasive form) : SC (PC or APC), FC (PC or APC), ST (PC), SMA(PC)
Delivery length : maximum 1,500 m
Construction
Loose tube type
Loose tube Center strength memberJelly filled or dry type Water proof tape Inner sheath (optional) LAP tape (optional)Outer sheath
Tight bound type
Wrapping tape Central strength member
Tight buffer tube PE coating FillerOuter sheath
Ribbon slot type
Ribbon optical fiber Water proof tapeUnit strength member Aluminum tape Outer sheath
Optical Apparatus _ 31
Optical Apparatus
Optical Multi Jumper Cable
Feature
Application
Construction
Low cost Low connection lossAdditional access is not needed Diverse acceptability
Long-range optical transmission network Optical subscriber networkOptical CATV network Optical LAN system
Applied Specification
Cable Form : Breakout cable, Distribution cableNo. of Cores : maximum 72 Applied Connector (abrasive form) : SC (PC or APC), FC (PC or APC), ST (PC), SMA (PC)
Delivery Length : maximum 500 m
Breakout Cable
Optical fiber UV- acrglatePVC or nylon Kevlar PVC sheath
Central strenght memberOuter sheathRip cord
Distiribution Cable
Central strength memberOuter sheathTight buffer coatingRip cord
32 _ Optical Apparatus
Optical Apparatus
Optical Distribution Frame
Convenient handling 19Rack applied Various sorts of cable can be applied
Feature
Long-range optical transmission network Optical subscriber networkOptical CATV network Optical LAN system
Application
Specification
Item ODF-36C ODF-48C ODF-144C
48338044
12/24/36 F (SC type)
12/24 F (SC type)
Size ( )
Number of Access Mounting
Adapter type
Access form
Outer diameter ( )
Color
Material quality
48 F
483310222
SC, FC, ST, LC
Fusion, Mechanical
8 ~32
Beige, Silver Gray
AL, SPCC
200~500
14 F
ODF-36C ODF-48C ODF-144C
Rack
Optical Apparatus _ 33
Optical Apparatus
Fiber Optic Terminating Boxes
Low cost Safe connector protection and storageExcellent durabilityConvenient usability
Feature
Optical subscriber network Optical LAN systemLong-range optical transmission network
Application
Specification
Construction
Excess length
support plate
Excess length plate
Adapter blanket
Jumper code acceptance
Optical jumper code
withdrawal
Support line clamp
Cable lead-in
Item ODF-36C ODF-144C
33022080
5.8
24 cores
380260110
6.4
48 cores
3 (Cable lead-in : 2, optical jumper code lead-in : 1)
22
1
SC, FC, ST, LC
Steel with Iaminated coating, stainless steel (optional)
Indoor wall adhesion
Size ( )
Weight ( )
Number of lead-in entrance
Maximum outer diameter ( )
Number of excess length plate
Number of access mounting
Adapter type
Material quality of enclosure
Application
34 _ Optical Apparatus
Optical Apparatus
Fiber Optic Emergency Repairing Systems
Excellent durability Convenient application Standard fiber count : 1~12 Actualization of lightweight with optimum structureExcellent high-strength and bending performance Space saving designConvenient mobility Compatible with various connectors
Feature
Emergency restoration Temporary installation of communication system Military operational communication system
Application
Construction
Optical fiber Single mode optical fiber (SMF), multi mode optical fiber (MMF), non-zero dispersion shifted optical fiber (NZ-DSF)
Center tensile line FRP or aramid yarn
Reinforcer Aramid yarn
Tape Plastic tape
Sheath Polyethylene, PVC or polyurethane
Optical Apparatus _ 35
Cable Specification
Specification
Optical cable
Reel
Reel carrier
-
-
-
Below 15 /Set
Below 10 /Set
Below 5 /Set
In case of 6 cores
Winding device of optical cable
Optical cable transportation and storage device
Recommended 500m
1 Set
1 Set
Item Quantity Weight WeightApplication and function
Mechanical & Environment Characteristic
0.9 PVC or acrylate coating core wire
FC, SC, ST Type
Aluminum or special alloy
5~25
5~8
10~30
Content
-
-
f
/
-
Unit
Types of optical fiber
Connector
Outer diameter
Cable weight
Transportationequipment
Material quality
Weight
Item
Over 100
3
20 Times of Cable External Diameter
10 Times of Cable External Diameter
-40~+70
100~1000
Content
f
/
m
Unit
Allowable tensile strength
Crush resistance
Operating temperature range
Delivery length
MinimumCurvature dia.
Dynamic
Static
Item
36 _ Optical Cables
Optical Cables _ 37
TAIHANs OPGW (Optical Fiber Ground Wire) series provide entirely new form of telecommunication line that is made
up of a ground wire for aerial power lines which contain optical fibers encased in an aluminum covered stainless steel
tube, aluminum tube or stainless steel tube. An OPGW combines a ground wire for shielding overhead power trans-
mission lines together with optical fibers for transmission of communication signals. The OPGW has been designed to
meet either the Electricalor the Mechanicalequivalent of conventional ground wire such as resistance of strong
winds, lightning and short circuit current.
OPGW
ContentsOptical Fiber Ground WireStainless Steel Loose Tube Type OPGW 38Non-metallic Loose Tube Type OPGW 39Central Stainless Steel Loose Tube Type OPGW 40Al Covered Stainless Steel Loose Tube Type OPGW 41
38 _ Optical Fiber Ground Wire
Optical Fiber Ground Wire
Stainless Steel Loose Tube Type OPGW
Standard 6 to 144 fiber count Power line protectionExcellent crush resistance performance Good resistance to strong winds, lightning and short circuit currentMaintenance data information system
Feature
ITU-T G. 650, 651, 652, 655, IEEE 1138, IEC 60793, IEC 60794
Application Specification
Cable Specification
Identification
of Optical Fiber
Sectional area
No. of fibers
Construction
Central AS wire
Steel tube
1 st Layer AS wire
2 nd Layer Al alloy
Outer diameter
Unit weight
Min. tensile load
Short circuit current capacity
Modulus of elasticity
Linear expansion coefficient
Max. allowable temperature
AS wire
Al alloy
Item Unit Specifications
Optical fiber Single mode optical fiber (SMF), multi mode optical fiber (MMF), non-zero dispersion shifted optical fiber (NZ-DSF)
Filling compound Jelly compound Steel tube Stainless steel tube AS wire or Al alloy Aluminum clad steel wire or Aluminum alloy wire AS wire or Al alloy Aluminum clad steel wire or Aluminum alloy wire
Construction
24 Core 48 Core
AS Wire : Aluminum clad steel wire
Core
No./
/
f
kA2s
f/
/
24
48
12
1/2.25
1/2.20
5/2.25
12/2.25
11.3
300
4200
39
9400
17.210-6
200
44
88
24
1/3.05
1/3.00
5/3.05
12/3.05
15.3
550
7800
130
9400
17.210-6
200
54
109
36
1/3.40
1/3.35
5/3.40
12/3.40
17.0
680
9700
200
9400
17.210-6
200
63
125
48
1/3.65
1/3.60
5/3.65
12/3.65
18.3
780
11200
270
9400
17.210-6
200
52
125
96
1/3.65
1/3.60
4/3.65
12/3.65
18.3
740
10000
245
9100
17.710-6
200
1
2
3
4
5
6
7
8
9
10
11
12
Blue
Orange
Green
Brown
Slate
White
Red
Black
Yellow
Violet
Pink
Aqua
No. offiber
Color
Optical Fiber Ground Wire _ 39
Optical Fiber Ground Wire
Non-metallic Loose Tube Type OPGW
Standard 6 to 48 fiber count Excellent water resistance performancePower line protection Maintenance data information system Good resistance to strong winds, lightning and short circuit current
Feature
ITU-T G. 650, 651, 652, 655, IEEE 1138, IEC 60793, IEC 60794
Application Specification
Optical fiber Single mode optical fiber (SMF), multi mode optical fiber (MMF), non-zero dispersion shifted optical fiber (NZ-DSF)
Loose tube Thermoplastic material (polybutylene terephthalate) Central member Fiber reinforced plastic (FRP) Filling compound Jelly compound Wrapping tape Heat resistance tape Al tube Aluminum tube AS wire or Al alloy Aluminum clad steel wire or Al alloy wire
Construction
Cable Specification
Item Unit Specifications
12010070
48
17.2
940
14500
155
13600
14.1 x 10-6
200
48
16.4
820
12500
125
13300
14.3 x 10-6
200
24
16.3
875
13500
130
13700
14.0 x 10-6
200
24
15.4
760
11700
105
13400
14.2 x 10-6
200
24
13.6
550
7880
66
12600
14.7 x 10-6
200
Core
/
f
kA2s
f/
/
24 Core 48 Core
No./Construction
Short circuit current capacity
Linear expansion coefficient
Max. allowable temperature
1/8.7 OP+14/2.43 AS
1/8.7 OP+11/3.34 AS
1/9.7 OP+12/3.31 AS
1/8.7 OP+10/3.8 AS
1/9.7 OP+11/3.74 AS
Sectional area
No. of fibers
Modulus of elasticity
Outer diameter
Unit weight
Min. tensile load
Identification
of Optical Fiber
1
2
3
4
5
6
7
8
9
10
11
12
Blue
Orange
Green
Brown
Slate
White
Red
Black
Yellow
Violet
Pink
Aqua
No. offiber
Color
40 _ Optical Cables
Optical Fiber Ground Wire
Central Stainless Steel Loose Tube Type OPGW
Standard 6 to 48 fiber count Light weight and small diameterExcellent crush resistance performance Power line protectionMaintenance data information system Good resistance to strong winds, lightning and short circuit current
Feature
ITU-T G. 650, 651, 652, 655, IEEE 1138, IEC 60793, IEC 60794
Application Specification
Cable Specification
Optical fiber Single mode optical fiber (SMF), multi mode optical fiber (MMF), non-zero dispersion shifted optical fiber (NZ-DSF)
Jelly compound Jelly compound Color binder Polyester yarns Stainless steel tube Stainless steel loose tube AS wire or Al alloy Aluminum clad steel wire or Al alloy wire
Construction
AS Wire : Aluminum clad steel wire, SSLT : Stainless steel loose tube
Sectional area
No. of fibers
Construction
Outer diameter
Unit weight
Min. tensile load
Short circuit current capacity
Modulus of elasticity
Linear expansion coefficient
Max. allowable temperature
Unit
Core
No./
/
f
kA2s
f/
/
Specifications
58
24
1/3.5 SSLT + 6/3.5 AS
10.5
410
7000
15
16500
13 10-6
200
68
36
1/3.8 SSLT + 6/3.8 AS
11.4
480
8000
21
16500
13 10-6
200
75
48
1/4.0 SSLT + 6/4.0 AS
12.0
530
9000
26
16500
13 10-6
200
Item
Optical Cables _ 41
Optical Fiber Ground Wire
Al Covered Stainless Steel Loose Tube Type OPGW
Standard 6 to 48 fiber count Excellent water resistance performancePower line protection Maintenance data information system Good resistance to strong winds, lightning and short circuit currentLight weight and small diameter
Feature
ITU-T G. 650, 651, 652, 655, IEEE 1138, IEC 60793, IEC 60794
Application Specification
Construction
Cable Specification
Optical fiber Single mode optical fiber (SMF), multi mode optical fiber (MMF), non-zero dispersion shifted optical fiber (NZ-DSF)
Jelly compound Jelly compound Stainless steel tube Stainless steel loose tube Al tube Aluminum tube AS wire or Al alloy Aluminum clad steel wire or Al alloy wire
AS Wire : Aluminum clad steel wire
Sectional area
No. of fibers
Construction
Outer diameter
Unit weight
Min. tensile load
Short circuit current capacity
Modulus of elasticity
Linear expansion coefficient
Max. allowable temperature
Unit
Core
No./
/
f
kA2s
f/
/
Specifications
83
1/5.5 Al tube +
8/3.3 AS
12.1
520
8300
40
14800
13.4 10-6
200
68
1/5.5 Al tube +
9/2.75 AS
11.0
420
6500
28
14500
13.6 10-6
200
60
1/5.5 Al tube +
10/2.4 AS
10.3
365
5500
23
14200
13.8 10-6
200
105
1/6.2 Al tube +
8/3.75 AS
13.7
665
10700
64
15000
13.3 10-6
200
85
1/6.2 Al tube +9/3.1 AS
12.4
530
8250
44
14600
13.5 10-6
200
74
1/6.2 Al tube +
10/2.7 AS
11.6
450
6950
35
14400
13.7 10-6
200
Item
6 ~ 24 48
42 _ Optical Cables
Optical Cables _ 43
TAIHANs FTTH linking quality optical cables to the home is used for high-speed network up to 1Gbps. By adopting this sys-
tem, the ubiquitous world is being realized in home network, VoD, IP based HDTV, telemedicine, videophone, and high-speed
Internet that we have been dreaming of. We lead the next-generation broadband communication infrastructure with T-Way,
an optimal FTTH total solution based on GE-PON system, which covers from system design, installation, construction to
supervision.
FTTH
ContentsFTTHGE - PON based FTTH System 44FTTH Total Solution T-WAY 46Network Application (in Apartment) 46E -PON OLT System 47E -PON ONT System 48E -PON ONU System 48EMS (Element Management System) 49Types of Optical Fiber Cable 50TBF System 51TBF System 52Optical Splitter 53Optical Distribution Frame 54Field Assembling Connector 54Optical Termination Box 55Optical Splicing Box 56RN Tray (Remote Node) 57FTTx Wiring System 57
44 _ FTTH
GE - PON based FTTH System
TAIHANs FTTH system adopts GE-PON technology on Ethernet base. GE-PON system pro-vides maximum ten times faster speed than VDSL system and delivers easy installation andmaintenance. It also provides the most competitive price among various PON systems and ismost popular in Korean and Asian markets as well.
Coverged services providing broadcasting, high quality internet and VoIP.
PON : Passive optical network ONT : Optical network terminal
OLT : Optical line terminal ONU : Optical network unit
APPLICATION
CATV, Satellite
Triple P
RF Video
Internet
IP Video
Voice
V-OLT
EMS
PON
OLT
CATV/satellite signal, 1550
24 E-PONinterfaces
1490
1310
WDM couple
FTTH
FTTH _ 45
[FTTP]
[FTTH]
Play Service
ONT
Voice
ONU
ONUUTP
FTTP : Fiber to the pole
FTTH : Fiber to the home
Optical splitter (116/32)
SMF 10~20
1:32
SMF
Date
Video
r
46 _ FTTH
FTTH Total Solution T-WAY
Network Application (in Apartment)
TAIHAN provides the most proper solution for installing FTTH network in economical way, and also pro-vides the network consulting and engineering services for TPS (Broadcasting, Telephony and Internet).
1. Network planning and cost estimation 4. Technical consultation2. Site survey and detailed design 5. Consultation for BOT (built, operation3. Installation and test and transfer) business
Engineering services by TAIHAN are :
Informationacquisition
Customer satisfactionoptimal solution
Needsanalysis
Design
Integration
Operation
Management
Product selection
FTTH
FTTH
MDF of apartment
Configuration in Flat
Abbreviation
Co : Central office
OFC :Optical fiber cable
BTB : Building termination box
FTB : Floor termination box
S : Subscriber
POC : Passive optical component (splitter)
STB : Set top box
OFC
Patch cord
Outlet
UTP 5e
ONT
UTP 5e
IP STB
VolP phone
BTB
GbEMax.4
fromISP
E-PON(Max.24)
1:16 or 1:32
FTTH _ 47
E - PON OLT System
E-PON OLT system consists of Gigabit ethernet switch and GE-PON master, and is installed in either telecomoffice or control room of residential apartment. 4 ports of GbE interface are connected to ISP (internet serviceProvider) and 24 ports of E-PON interface are connected to total 768 ONT systems by point to multi-pointarchitecture. If V-OLT module is added, satellite and CATV broadcasting services can be provided.
Item ItemSpecification Specification
Minimize the cable installation and maintenance cost bysupporting max. 32 branching off per port.
Provide 1Gbps full-duplex speed per port with just 1 fiberProvide broadcasting, IP telephony and internet servicesCompliant to IEEE 802.3ah standardSupport SLA and DBA function that control flexibleup/down bandwidth per ONT.
TPS (Triple Play Service)
Provide 12 slots for E-PON interface boardProvide maximum 24 ports of E-PON interface (2 ports per board)Provide 4 ports of Gigabit ethernet interface for WAN and serverconnection
Support 100 Mbps interface for IP-TV exclusiveEthernet based packet forwardingL2/L3 switching functionSupport service priority by setting SLA and bandwidth per LLID Efficient system monitoring and configuration through EMS
Feature
High quality internet service IP-TV service through internetCATV or Satellite service by using Video-overlay module
Application
Max. 28 Gbps switching capacity
1000 base-Tx interface : 2 ports
1000 base-Tx/Fx interface (SFP GBIC) : 2 ports
Gigabit interface module : 1
E-PON line interface module : 12
Fan module : 1
24 ports of E-PON interface (2 ports/module)
EEE802.3 ah
- MPCP master/Slave function
- IEEE802.3 ah full-duplex MAC for each LLID
- IEEE 802.3 ah Link OAM protocol
SLA per LLID
Max. 64 LLIDs per E-PON interface
IEEE 802.1p (priority)
IEEE 802.1q (VLAN)
IEEE 802.3 ad (link aggregation)
IEEE 802.1d (STP)
Layer 3
Multicasting
QoS
Filtering
Management
Size( )
Capacity
NetworkManagement
Slot
E-PONInterface
E-PONFeatures
Layer 2
Static routing
Dynamic routing (OSPFv2, RIPv1/2)
DHCP server/relay
IGMPv1/2, PIM-SM
IGMP snooping
Packet classification/marking/remarking
Congestion management
SPQ, WRR
Packet classification and queue allocation for L2/L3/L4 header
DSCP/TOS and 802.1p support
DHCP filtering
NetBeui, NetBIOS, NBT filtering
Limitation of MAC number per ONTONT operation and maintenance through OLTRemote software upgradeGUI based operation and maintenance through EMS
440(W) x 260(H) x 320(D)
FTTH
48 _ FTTH
E - PON ONT System
E-PON ONT system consists of GE-PON slave and 4ports of 100Base-Tx Interface, and is installed atsubscriber premises. Since 1 port of 100Base-Txinterface is designed to process the high prioritypackets, IP-TV service may be much stably provid-ed, and remaining 15 ports of 100 Baxe-TX interfaceprovide high quality internet and data services.
Item ItemSpecification Specification
1 Gbps E-PON Interface : 1port
IP-TV exclusive 100 Base-Tx Interface : 1 port
100 Base-Tx Interface : 15 ports
Satellite or CATV RF Interface (Optional)
IEEE 802.1q (Mapping VLAN to LLID)
Multiple LLID support and SLA function per LLID
MAC management
Filtering
QoS
Management
Size( )
E-PON Interface
EthernetInterface
Layer 2
DHCP filtering
NetBeui, NetBIOS, NBT fitering
Limiting the number of MAC
4 queues support per LLID
SNMP/EMS O & M support through OLT system
Remote software upgrade
178(W) x 42(H) x 185.5(D)
E -PON ONU System
TAIHANs E-PON system can be deployed to FTTP(Pole), FTTB(Building) and FTTZ(Zone) applications asper request of customer. This system supports 1 port of E-PON interface and 24 ports of 100Base-Txinterface, and provides the high quality multi-media services of Broadcasting, IP telephony and Internet.
Item ItemSpecification Specification
1 Gbps E-PON interface 1 port
100 base-Tx interface 24 ports
IEEE 802.1q (VLAN)
IEEE 802.1p (Packet Priority)
IEEE 802.1d (STP)
IGMP Snooping
Filtering
QoS
Management
E-PON
EthernetInterface
Layer 2
Multicasting
DHCP filtering
NetBeui, NetBIOS, NBT fitering
Limitation of MAC number
Packet classification
SPQ, WRR
Marking / remarking
Rate limiting per port (1M unit)
ONT operation and maintenance through OLT
Remote software upgrade
FTTH
FTTH
FTTH _ 49
EMS (Element Management System)
Requirements for EMS Hardware
By adopting element management system, network operator can easily manage the E-PON OLT and ONTsystem at remote site. EMS consists of EMS Manager as a server and EMS agent for communication withE-PON system. With this EMS system, unified network management is available.
Provide SNMP interfaceWeb-based system management functionEasy and convenient GUI interfaceConfiguration management : addition, deletion and change for OLT and ONT interfaceFault management : real-time monitoring and history & statistics management for malfunctionAuto discovery function for system addition/deletionPerformance management : performance and critical value management for OLT/ONT/CPU Protocol management : protocol management for TCP/IPOperator management : record of addition, deletion, change and connection history
Feature
Network management NE Control / administration
Description Requirements
Pentium 4, 3GHz
1 GB
60 GB
Minimum SVGA 1024 x 768
Windows 2003 server
MS-SQL server
Processor
RAM
HDD
Monitor
O/S
Database
FTTH
50 _ FTTH
Types of Optical Fiber Cable
Tight buffered optical fiber
Aramid yarn
Outer sheath
Suspension wire
Round Type AerialDrop Cable
Optical fiber
Loose tube
Aramid yarn
Outer sheath
Central Loose Type Drop Cable
Tight buffered optical fiber
Aramid yarn
Outer sheath
Single Sheath Type Drop Cable
Tight buffered optical fiber
Aramid yarn
Inner sheath
Aramid yarn
Outer sheath
Double Sheath Type Drop Cable
Tight buffered
optical fiber
Aramid yarn
Outer sheath
Single Unit HybridCable(SMF+MMF)
Tight buffered optical fiber
Aramid yarn
Central strength
member
Rip cord
Outer sheath
Multi Unit Hybrid Cable
FRP
Optical fiber
Outer sheath
Flat type Indoor cable
UTP cable pair
Outer sheath
Tight buffered
optical fiber
Optical/UTP Composite Cable(for FTTH)
FTTH Drop Cable
FTTH Indoor Cable
FTTH
FTTH _ 51
TBF System
Ripcord Acrylate coatingOptical Fiber(SMF, MMF)
8C 4C 2C 2C (Ripcord)
Air Blown Fiber UnitThe TAIHAN units are contained in a soft inner acrylate layer for cushions.An outer harder layer protects the fibre from damage and a low friction layer.It assists in improving blowing distance which is typically in excess of 1000m in a single direction.It is available in lengths up to 6000 metres.
1.0
0.8g/m
blue, orange
1.0
0.8g/m
blue, orange, green,red
1.4
1.5g/m
blue, orange, green,red, violet, grey, yellow,
brown
1.3
1.55 g/m
blue, orange, green, red,violet, grey, yellow, brown,black, White, Pink, turquoise
Diameter
Weight
Fibre colors
2 Fibre 4 Fibre 8 Fibre 12 Fibre
Maximumattenuation
(dB/)
Bandwidth(MHz.)
WavelengthSinglemode(G.652b)
MM62.5/125
MM50/125
OM3 OM3ELow water peak(magnilight G.652b)
Tensile strength
Crush
Bend
Aged bend
Temperature
Cold test
Condensation test
Water immersion
Fibre breakout form unit
MechanicalInternational standard Test conditions Performance
Properties
Transmission Performane
IEC 60794-1-2-E1
IEC 60794-1-2-E3
IEC 60794-1-2-E11
BT CW 1500 pt 4
1W N (9.81 mass of 1 )
100N for 60 seconds
40 (2 & 4f), 60 (8f)
40 (2 & 4f), 60 (8f) at 60 for 1000 hrs
Pass. maximum fibrs strain = 0.4%Residual fibre strain = 0.05%. note 1, note 2
Pass. note 1, note 2
Pass. note 1, note 2
Pass. note 1
Environmental
IEC 60794-1-2-F1
BS EN 60068-2-1
IEC 60068-2-38
BT CW 1500 pt 4
BT CW 1500 pt 4
850
1300/1310
1383
1550
850 minimum modal
850 effective modal
1300/1310
-
0.38
-
0.26
-
-
-
-
0.38
0.35
0.26
-
-
-
3.5
1.0
-
-
200
-
600
2.6(2f-3.2)
0.8(2f-1.2)
-
-
500
-
800
2.6(2f-3.2)
0.8(2f-1.2)
-
-
1500
2000
500
2.6(2f-3.2)
0.8(2f-1.2)
-
-
3500
4700
500
-10 to + 60 for 3 cycles
-20 for 96 hours
-10 to + 65 at 93%RH for 24 hrs 10
20 5 for 2000 hours
0, 20, 40, length 2m
Pass. note 3, note 4
Pass. note 3, note 4
Pass. note 3, note 4
Pass. note 3, note 4
Under 3 minutes(2 & 4f)Under 5 minutes(8f)
FTTH
Note1. no significant dam age Note2. no change in attenuation after test Note3. pass for singlemode = 0.07 dB/km at 1310 nm and 1550 nm Note4. pass for multimode = 0.25dB/km at 850 nm and 1300 nm
52 _ FTTH
TBF System
Gas seal connector
Tube connector
Tube sealing cap
Water blockingconnector
End cap
12-way
1
2
3
4
1 = Micro tube
2 = Aluminium layer
3 = Inner sheath
4 = Rip cord
7-way2-way1-way 4-way
Air Blown Tube CableAluminium tape layer acts as a moisture barrierRapid dedicated customer connections using proven mechanical protection of HDPELow friction internal coating for maximum fibre blowing distanceEach tube accommodates one fibre unit(up to 12 fibres in unit)Can be composed flexible tube routing
1-way
2-way
4-way
7-way
12-way
19-way
24-way
Way Type Outer Dia.() Band Tensile Crush Packing
Aluminium
swellable tape
metal free
5m/3.5m
12.8
12.817.8
19.9
22.8
28.1
32.8
37.9
192
192266
298
342
422
492
568
1.1
1.6
2.3
2.9
4.0
5.2
6.5
2
2
2
2
2
2
2
2,000
Tube ConnectorsStraght connector : Used for simple fit connection of 5 to 5 TBF tubingGas seal connector : used for gas sealing TBF tubing entering a customers premises and providing
a gas tight seal for tubesSealing cap : Used for gas sealing unused TBF tubing entering internal plantWater blocking connector : Used for Water blocking TBF tubing entering underground external plantEnd cap : Used for terminating unused TBF Tubing Within external plant
FTTH
FTTH _ 53
Optical Splitter
Size (LxWxT) [ ]
Common port fiber
Distribution port fiber
Housing material
Sealing material
Common port fiber length (m)
Distribution port fiber length (m)
Fiber specification
Insertion loss (dB)
Loss uniformity (dB)
PDL (dB)
Return loss (dB)
Wavelength ( )
Item1x4 1x8 1x16 1x32
40x4x4
250
4F ribbon
7.6
0.8
0.3
55
40x4x4
250
4F ribbonx2
11.0
1.2
0.3
55
50x5x4
250
8F ribbonx2
14.0
1.4
0.4
55
50x7x4
250
8F ribbonx4
17.8
2.0
0.4
55
Aluminum alloy or stainless steel
Silicon rubber
1.5
1.5
ITU-T G652
1260~1625
Specification
Fiber Color
Channel number Color
Blue
Orange
Green
Brown
State
White
Red
Black
1
3
5
7
9
11
13
15
2
4
6
8
10
12
14
16
17
19
21
23
25
27
29
31
18
20
22
24
26
28
30
32
FTTH
54 _ FTTH
Field assembling connector can be assembleddirectly on 250um or 900um size of optical fiber byimproving the conventional mechanical jointing method.
Its work efficiency is largely improved as the assem-bling is carried out simply and rapidly at site withoutgrinding optical fiber in the field. Additional tool is notrequired and wedge inside connector packing isused for assembling.
Field Assembling Connector
Characteristic Types of fiber Wavelength () Avg. loss Max. loss
Insertion loss
Return loss
Single mode
Single mode
Multi mode (50/125)
Multi mode (62.5/125)
Single mode
Single mode
Multi mode (50/125)
1310
1550
1310
1310
1310
1550
1310
0.19dB
1.18dB
0.07dB
0.03dB
56.1dB
56.4dB
37.6dB
0.37 dB
0.34 dB
0.38 dB
0.21 dB
43.9 dB
44.5 dB
32.0 dB
FTTH
FTTH _ 55
Optical Termination Box
The optical termination box is used for inter-connecting of optical fiber purpose at subscriber premisesindoor or outside of the home. Featuring mechnical and environmental protection for both fiber and itscomponents, it provides a transition point between outside plant cable and patch cords in fiber optic net-work. It is designed with controls that maintain the fiber bend radius throughout the unit on the segregatedcustomer and provider sides. For convenient cable management, they provide termination, splicing andstorage functions for fiber optic cable systems.
Size ( )
Weight ( )
Inlet ports ( )
Cable diameter ( )
No. of splice trays
Splice capacity
Optical adapter
Material
ItemOTB-4 OTB-8 OTB-16 OTB-32
400x250x80 400x300x80
5.2 5.2 5.2 5.8
1/4 (drop) 1/8 (drop) 1/16 (drop) 1/32 (drop)
20/5 (drop)
1 up to 2
4F 8F 16F 32F
SC, LC
SPCC, SUS, AL
Specification
FTTH
56 _ FTTH
Optical Splicing Box
Optical splicing box is used to protect fiber optic splicing point from outside environment in various instal-lation conditions such as aerial, manholes, ducts and direct buried. It is specially designed for FTTH net-work and applicable to multi branching installation by using mid-plate which is for increasing core capac-ity and complying with the requirements in each point of network. The flat type gasket ensures reliablesealing performance by preventing air and water leak and the corn type sheath gasket is available toaccommodate varying size of cable diameter. The closure has high mechanical strength against any envi-ronmental conditions. With this closure, you can improve your network system to the higher level.
BS403A-SS Mid-plate BS403A-SS
Mid-plate BS403A-SD
Characteristic Types of fiber Wavelength () Avg. loss
Size ( )
Weight ( )
Inlet ports (Max)
Cable diameter
No.of splice trays
Tray capacity
Splice capacity
Splice method
Splice protector
Tension member
435 x 205 x113
2.8
4(32)
6 ~ 20
4
24F ~ 48F
96F ~ 192F
Fusion, mechanical,connector
Heat shrinkable sleeve, ribbon protection sleeve, mechanical splice
Galvanized steel wire, FRP
435 x 205 x167
3.8
8(64)
6 ~ 20
6
24F ~ 48F
144F ~ 288F
435 x 205 x221
4.8
12(96)
6 ~ 20
8
24F ~ 48F
192F ~ 384F
Increasing entry ports by using mid-plateProven water tightness by silicon rubber gasketRN tray use for splitter, ribbon and loose tube fiber splicingHigh mechanical strength against impact and compressionEase of use for closure assembly
Feature
FTTH
FTTH _ 57
RN Tray (Remote Node)
FTTx Wiring System
Ribbon cable for heat shrinkable sleeve
Tray bottom
Loose cable for heat shrinkable sleeve
Splitter(1*32)
HIinge Fiber stopper
Splitter(1*32) Item Specification
Splice capacity
Splice method
Storage method
Bend radius
Use
20F (single stack fusion mechanical)
72, 64, 40F (Ribbon)
single/multi fusion, mechanical, splitter
sigle, dual
30
Fiber to fiber, fiber to pigtail
FTTH
FTTH
APPENDIX
ContentsProduct Certificates 60System Certificates 61Definition of Terms 62Global Network 64
60 _ APPENDIX
Product Certificates
The outstanding quality of TAIHAN communication cables is verified by internationally accredited certification institutes.
Product certificates
Institute Certificate number Item Type Standard Issue date
UnderwritersLaboratories Inc.
(USA)
TelcordiaTechnologies
(US)
210100-E111385
240100-E111358
210600-E111358
220600-E111358
000111-E111358
000211-E111358
000311-E111358
000411-E111358
113000-E111358
-
Communicationscable
Communicationscable
Data cable
Data cable
Data cable
Data cable
Communicationscable
Communicationscable
Data cable
Optical fiber
CM, 24 AWG, 4/PR-Category 5
CM, 24 AWG, 4/PR Cable
CMR, Cm, and CMX, 24 AWG 25/PR UTP Cable-Category 3, 4, and 5
CMR, CM, and CMX, 24 AWG 25/PR UTP Cable
CMR 24 AWG UTP Category 5e Cable
CM and CMX 24 AWG UTP Category 5e Cable
CM & CMX Cables Employing FoamedPE Insulation & PVC Jacket
CMR Cables Employing Foamed PEInsulation & PVC Jacket
CM or CMX Cables Also Verified inaccordance with Category 6, NEMA
WC-66-1999 UL 444. NEMA WC-66-1999
Dispersion-Unshifted, Low Water Peak Single-mode Optical fiber
TIA/EIA 568A
UL 444
TIA/EIA 568A
UL 444
UL 444, ANSI/TIA/EIA-568A-5
UL 444, ANSI/TIA/EIA-568A-5
UL 444
UL 444
UL 444. NEMA WC-66-1999
-
2000.01.21
2000.01.24
2000.06.21
2000.06.22
2000.11.01
2000.11.02
2000.11.03
2000.11.04
2000.11.30
2007.10.30
APPENDIX _ 61
System Certificates
TAIHAN has been assessed and certified as meeting the requirements of ISO 14001, ISO 9001 and TL9000 which sets global standards for manufacturing process.
System certificates
62 _ APPENDIX
Definition of Terms
Acrylate : A salt or ester of acrylic acid
Aerial Cable : A cable suspended in the air on poles or other overhead structures
Aramid Fiber : A class of heat-resistant and strongsynthetic fiber
AS Wire : Aluminum clad steel wire
Attenuation : Power loss in an electrical system
BcN : Broadband Convergence Network
CaCO3 : Calcium Carbonate
CATV : Community Antenna Television
Cladding : something that covers or overlays. Specifically, metal coating bonded to a metal core
Coaxial Cable : A cable consisting of two conductors with a common axis, separated by a dielectric
Copolymer : A polymer derived from two (or more)monomeric species, as opposed to a homopolymerwhere only one monomer is used
Core : A component or assembly of components overwhich additional components (shield, sheath, etc.) areapplied
CPU : Central Processing Unit
CSA : Canadian Standards Association
DBA : DataBase Administor
Decibel (dB) : A unit to express differences of power level.
DHCP : Dynamic Host Configuration Protocol, one ofthe protocols in the TCP/IP networking suite
Direct Buried Cable : A cable installed directly in the earth.
Dry Type Cable : Dry Block material or hydroscopictape used as a water blacking agent in cables.
DSCP : Differentiated Services Code Point, a field in the header of IP packets for packet classification purposes.
Duct : An underground or overhead tube through which electrical conductors are pulled.
DWDM : Dense Wavelength Division Multiplexing
EMS : Electro Magnetic Susceptibility
E-PON : Ethernet Passive Optical Network
Ethernet : A computer network architecture consisting of various specified local-area network protocols,devices, and connection methods
Fiber Optics : A lightwave or optical communicationssystems in which electrical information is converted tolight energy, transmitted to another location through optical fibers, and is there converted back into electricalinformation.
FRP : Fiber Reinforced Plastic
FTTH : Fiber To The Home
GBIC : Gigabit Interface Converter (1gigabit = one billion bits)
GE-PON : Gigabit Ethernet Passive Optical Network
GPS : Global Positioning System
GUI : Graphical User Interface
HDTV : High-Definition Television
Hygroscopic : Taken up and retained under some conditions of humidity and temperature.
IEC : Independent Electrical Contractors Association
IEEE : Institute of Electrical and Electronics Engineers
IGMPv1/2 : Internet Group Management Protocol
IPTV : Internet Protocol Television
ISO : International Standards Organization
ITU - T : International Telecommunication Union - Telecommunication Standardization Sector
KS : Korean (Industrial) Standards
KT : Korea Telecom
LAN : Local Area Network. Integration of computer andcommunication systems that wire computers, peripheral equipment and telephones together.
LAP : Laminated Aluminum Polyethylene
LLID : Logical Link Identifier
APPENDIX _ 63
LSZH : Low Smoke Zero Halogen
LWPF : Low Water Peak Fiber
MAC : Media Access Control
Mbps : Megabits per second (1megabit = one million bits)
MFD : Mode-Field Diameter
MMF : Multi Mode Fiber
MPCP : Multi-Point Control Protocol
Mylar : DuPont trademark for a polyester material usedin the form of a tape.
NBT : A networking protocol that allows legacy computer applications relying on the NetBIOS API to beused on modern TCP/IP networks.
NE : Network Element
NetBeui : NetBIOS Extended User Interface
NetBIOS : Network Basic Input/Output System
NZDSF : Non Zero Dispersion Shifted Fiber
OAM : Operations, Administration and Maintenance
OLT : Optical Line Termination
OSPFv2 : Open Shortest Path First Version 2
OTB : Optical Termination Box
PDL : Polarisation Dependent Loss
PE : Polyethylene
PIM-SM : Protocol Independent Multicast, Sparse-Mode
Polyethylene : A thermoplastic material having thechemical identity of polymerized ethylene.
Polymer : A chemical compound with large moleculesmade of many smaller molecules of the same kind.
Polyurethane : A plastic material used especially tomake paint or substances which prevent water or heatfrom passing through.
PON : Passive Optical Network
PVC : Poly-Vinyl Chloride
QoS : Quality of Service
RIPv1/2 : Routing Information Protocol
RN : Remote Node
SFP : Small Form-factor Pluggable
SLA : Service Level Agreement
SMF : Single Mode Fiber
SNMP : Simple Network Management Protocol
SPCC : Steel Plate Cold Commercial
SPQ : Strict Priority Queuing
Stalpeth : A cable sheath consisting of a corrugated steel (ST) shield applied over a corrugated aluminum(AL) shield and an outer polyethylene (PETH) jacket.
SUS : Steel Use Stainless
TCP/IP : Transmission Control Protocol-Internet Protocol
Terephthalate : A dimethyl-ester that is a major starting material for polyester fibers and coatings.
Thermoplastic : Capable of softening or fusing whenheated and of hardening again when cooled.
ToS : Type of Service
UL : Underwriters Laboratories, a non-profit independent organization, which operates a testing andlisting service for electrical and electronic materials and equipment.
UM : Micrometer (1um = 1,000 )
UV : Ultraviolet
VAD : Vapour phase Axial Deposition
VDSL : Very high-Data rate digital Subscriber Line
VolP : Voice over Internet Protocol
WDM : Wavelength Division Multiplexing
WRR : Weighted Round Robin
ZWPF : Zero Water Peak Fiber
Global Network
South AfricaM-TEC (Malesela Taihan Electric Cable(Pty)Ltd.)Vereeniging 1930, Steel Road, Peacehaven Vereeniging 1939, Gauteng, South AfricaTEL : +27-16-450-8333 FAX : + 27-16-450-8202E-mail : [email protected] : www.m-tec.co.za
D.R.Congo_ STANDARD TELECOM 158, Avenue de la democratie(Ex-Huilerie) Commune de la Gombe, Kinshasa, D. R.CONGOTEL : +01-511-0002 FAX : + 01-511-1100E-mail : [email protected]
Vietnam_TSC (Taihan Sacom Cable Company.,Ltd)7th Floor, 71-73 Dien Bien Phu, phuong 15, BinhThanh District , VietnamTEL : +8461-351-4145 FAX : +8461-351-4211E-mail : [email protected] : www.tsc.vn
Hong Kong_TGH (Taihan Global Holdings)No.1808, 18/F,Tower 2,Admiralty Center,18 HarcourtRoad, Admiralty, Hong Kong
Mongolia_SKYTEL3rd FL, Skytel Plaza Bldg, Chinggis khaan Avenue-9,Ulaanbaatar-13, MongoliaTEL : +976-1131-8488 FAX : +976-1131-8487 E-mail : [email protected] Website : www.skytel.mn
SKYNETWORKS4th FL, Skytel Plaza Bldg, Chinggiskhan Avenue-9,P.O.B 2033 Ulaanbaatar-211213 MongoliaTEL : +976-9111-7463 FAX : +976-1131-8841 E-mail : [email protected] Website : www.skynetworks.mn
USA_Taihan USA (Taihan Electric USA., Ltd.) LandMark Building, 99 Tulip Avenue, Suite#106,Floral Park, NY 11001, USATEL : +1-516-355-5600 FAX : +1-516-355-5601 E-mail : [email protected]
Canada_Taihan Global Canada Investment.,