In-Chassis Gateways Wireless Communication Solutions for Rockwell Automation ® Users Where Automation Connects ASIA PACIFIC | AFRICA | EUROPE | MIDDLE EAST | LATIN AMERICA | NORTH AMERICA

Communication Solutions for Rockwell Automation Users · PDF fileCommunication Solutions for Rockwell ... feature. With PDS, you don’t have to change your PC ... • Enables your

Embed Size (px)

Citation preview

Page 1: Communication Solutions for Rockwell Automation Users · PDF fileCommunication Solutions for Rockwell ... feature. With PDS, you don’t have to change your PC ... • Enables your

In-ChassisGateways

Wireless

Communication Solutions for Rockwell Automation® Users

Where Automation

Connects

A S I A P A C I F I C | A F R I C A | E U R O P E | M I D D L E E A S T | L A T I N A M E R I C A | N O R T H A M E R I C A

Page 2: Communication Solutions for Rockwell Automation Users · PDF fileCommunication Solutions for Rockwell ... feature. With PDS, you don’t have to change your PC ... • Enables your

ASCII

BASIC

Bristol Babcock

DF1 Master/SlaveDH-485

DNP3

DNP3 Ethernet

EtherNet/IP

Ethernet Global Data

FA Control/Network

Generic EthernetHART

Honeywell DE Master

IEC 61850

IEC 60870-5-101

Johnson Controls MetasysLimitorque Master

Siemens Industrial Ethernet

IEC 60870-5-104

BACnet

LonWorksModbus

Modbus Plus

Modbus TCP/IPPROFIBUS

Siemens 3964R

FLRUN

Allen-Bradley

FLTBATT

FORCEDH485Modbus

RUN PROG

RTU 5/05

Linux Development

COM

M A

DAPT

ER ETHP1

CFGBPOK

ETH

00:00:BC:68:0E:29

COM

M A

DAPT

ER ETHP1P2

CFGBPOK

ETH

P1App

P2App

10 2 3 4 5 6 7

1734-AENT

SystemPower

FieldPower

ModuleStatus

NetworkStatus

TxD

RxD

NODE:

ILX34MBS485

RS232MODBUS

2 www.prosoft-technology.com

Who we areAt ProSoft Technology® our primary focus is to provide connectivity solutions that link dissimilar automation products.

In everything we do, the products we develop and the services we offer, we consider quality a priority. We don’t just sell products. We sell tested, field-proven solutions. Our goal is to support our customers from pre-sales through the entire life-cycle of the application. We provide total solutions with quality products developed with customers in mind, a well-respected brand and industry-leading technical support.

For years, ProSoft Technology products have been used worldwide in nearly every industry. Our product lines have grown to over 500 communication modules supporting more than 100 different industrial communication protocols. ProSoft Technology has regional offices around the globe along with worldwide distribution to meet all your industrial application needs.

Tech Support

See back cover for more

contact information.

ProSoft Technology's technical support is unparalleled in the industrial automation industry. To continue our world-class technical support, we have opened offices in most time zones in an effort to support our customers at a local level.

We don’t just sell products. We sell tested, field-proven solutions.

North AmericaCORPORATE OFFICEPHONE +1 661.716.5100EMAIL [email protected] English, Spanish

CHINA OFFICEPHONE +86.21.5187.7337EMAIL [email protected] Chinese, English

Europe, Middle East, AfricaMIDDLE EAST, AFRICA OFFICE PHONE +971.(0)4.214.6911EMAIL [email protected] English, Hindi

FRANCE OFFICE PHONE +33 (0)5.34.36.87.20EMAIL [email protected] French, English

Latin AmericaREGIONAL OFFICE PHONE +1.661.716.5276EMAIL [email protected] Spanish, English

BRAZIL OFFICEPHONE +55.11.5084.5178EMAIL [email protected] Portuguese, English

MEXICO, CENTRAL AMERICA OFFICEPHONE +52.222.3.99.6565EMAIL [email protected] Spanish, English

Asia PacificMALAYSIA OFFICE PHONE +60.3.7724.2080EMAIL [email protected] Bahasa, Chinese, English, Japanese, Korean

Page 3: Communication Solutions for Rockwell Automation Users · PDF fileCommunication Solutions for Rockwell ... feature. With PDS, you don’t have to change your PC ... • Enables your

ASCII

BASIC

Bristol Babcock

DF1 Master/SlaveDH-485

DNP3

DNP3 Ethernet

EtherNet/IP

Ethernet Global Data

FA Control/Network

Generic EthernetHART

Honeywell DE Master

IEC 61850

IEC 60870-5-101

Johnson Controls MetasysLimitorque Master

Siemens Industrial Ethernet

IEC 60870-5-104

BACnet

LonWorksModbus

Modbus Plus

Modbus TCP/IPPROFIBUS

Siemens 3964R

FLRUN

Allen-Bradley

FLTBATT

FORCEDH485Modbus

RUN PROG

RTU 5/05

Linux Development

COM

M A

DAPT

ER ETHP1

CFGBPOK

ETH

00:00:BC:68:0E:29

COM

M A

DAPT

ER ETHP1P2

CFGBPOK

ETH

P1App

P2App

10 2 3 4 5 6 7

1734-AENT

SystemPower

FieldPower

ModuleStatus

NetworkStatus

TxD

RxD

NODE:

ILX34MBS485

RS232MODBUS

3www.prosoft-technology.com

ProSoft Technology® offers communication interfaces for Rockwell Automation® platforms, including ControlLogix®, CompactLogix™ L3x, L2x, L1x, SLC™ 500, FLEX® I/O and POINT I/O™. Solutions include protocol interface modules for over 40 different networks, custom programmable modules, message managers and flow computers.

In-Chassis Interface Modules

Tutorial Videos AvailableProSoft Technology® has a number of tutorial videos available to help you get up and running on many of our products including:

• Understanding Modbus® for Rockwell Automation® Users

• Setup Tutorial for ICX30 Cellular Radios

• Modbus® Setup Tutorial for ControlLogix®

• PROFIBUS® DP Master Configuration Tutorial

• Setup Tutorial for 802.11 Industrial Hotspot Radios

• Setup Tutorial for Remote I/O™ to EtherNet/IP™ Migration Gateways

Visit psft.com/A8K to see our complete list of free training videos.

| For a list of our most popular in-chassis solutions and part numbers, see page 13.

Page 4: Communication Solutions for Rockwell Automation Users · PDF fileCommunication Solutions for Rockwell ... feature. With PDS, you don’t have to change your PC ... • Enables your

Modbus®

Flow Devices Drives PowerMeasurement

ActuatedValves

Loop Controllers

Master and SlaveExample

SCADA/DCS

Serial & Ethernet Modbus® SolutionsModbus® TCP/IP Features• Fast Multi-Server/Multi-

Client capabilities

• Add-On Instruction (AOI) reduces configuration effort and simplifies maintenance

Modbus® Serial Features• Module configuration stored within the Studio 5000®/RSLogix™

5000 project (ACD file) for simplified disaster recovery

• Add-On Profile (AOP) improves integration into Studio® 5000®/RSLogix™ 5000

• Add-On Instruction (AOI) reduces configuration effort and simplifies maintenance

Modbus®CompactLogix™ L2

Relay

CompactLogix L24ERQBFC1BRUN

FORCE

I/O

OK SD

LINK 2

LINK 1

NS

COM

M A

DAPT

ER

Scalable Modbus® & Modbus® TCP Solutions for CompactLogix™

Features• Enhanced modules allow up to 10,000 I/O words

• Lite modules allow up to 240 I/O words

• Integrated Modbus® Serial communications in 1734 Point I/O™ applications

Client and ServerExample

AC Drive

PLCPower Relay

Flow Device

Modbus® TCP/IPSCADA/DCS

SCADA/DCS

CompactLogix™ L3

Flow DevicePower Relays

PLC

CompactLogix L36ERMRUN

FORCE

I/O

OK

NS

LINK 1

LINK 2

SD

COM

M A

DAPT

ER

Modbus® TCP/IP

SCADA/DCS

Modbus®

CompactLogix™ L1CompactLogix L18ERM

RUN

FORCE

I/O

OK SD

LINK 2

LINK 1

NS

00:00:BC:68:0E:29

ModuleStatus

NetworkStatus

TxD

RxD

NODE:

ILX34MBS485

RS485MODBUS

4 For a list of our most popular in-chassis solutions and part numbers, see page 13; for gateways, page 14. | www.prosoft-technology.com

Page 5: Communication Solutions for Rockwell Automation Users · PDF fileCommunication Solutions for Rockwell ... feature. With PDS, you don’t have to change your PC ... • Enables your

5www.prosoft-technology.com | For a list of our most popular in-chassis solutions and part numbers, see page 13; for gateways, page 14.

Building Automation Solutions

Features• Ability to interface up to 500 Building

Automation Systems points of data

• BACnet® COV support for fast data communication while reducing traffic on the BACnet network

• DIP switches to select Baud rate or Node ID

• Common interfaces include Modbus® Serial, Modbus® TCP/IP, EtherNet/IP™, BACnet®/IP, BACnet®, LonWorks® and Johnson Controls Metasys® N2

Improve energy efficiencies by connecting your PLC/PAC control systems to your Building Automation Systems

Building Automation Gateways

Building Automation In-Chassis Modules

Ethernet and Serial Gateway SolutionsFeatures• Multiple I/O connections for fast real-time data

• 4,000-word database for large applications

• Bi-directional data transfer

• Remote Configuration and Diagnostics via Ethernet

• SD Card slot for disaster recovery of configuration data

• Up to four Serial ports

• Two-Ethernet-port gateway allows devices that speak different protocols to be on separate subnets, passing only the data you need

ProSoft Technology’s stand-alone, DIN-rail mounted industrial gateways provide a means to read or write data from devices on dissimilar protocols. Each EtherNet/IP™ gateway comes with an embedded EDS Add-On Profile. All gateways come with our ProSoft Discovery Service

feature. With PDS, you don’t have to change your PC to the default subnet of the module, saving you time during setup.

ASCII

Weigh ScaleSCADA/DCS

BarcodeReader

EtherNet/IP™

HMIPressure Valve

MicroLogix™ 1100 SCADA/DCS

Power Monitors

Modbus® Serial Modbus® TCP/IP

PLC

Siemens® Industrial Ethernet

PLC

CompactLogix™ L3

CompactLogix L36ERMRUN

FORCE

I/O

OK

NS

LINK 1

LINK 2

SD

CompactLogix™

CompactLogix L18ERM

RUN

FORCE

I/O

OK SD

LINK 2

LINK 1

NS

00:00:BC:68:0E:29

PLC

PROFINET®10.1.10.1 20.2.20.3

10.1.10.3

20.2.20.520.2.20.7

Power Relays

Drive

20.2.20.6

20.2.20.4

20.2.20.10

89

2

5

0

3

6

7

1

4

Page 6: Communication Solutions for Rockwell Automation Users · PDF fileCommunication Solutions for Rockwell ... feature. With PDS, you don’t have to change your PC ... • Enables your

6 www.prosoft-technology.comFor a list of our most popular in-chassis solutions and part numbers, see page 13; for gateways, page 14. | www.prosoft-technology.com

ControlLogix®

E1

E2

ERR APP OK

10/100

LINK/ACT

CONFIG

10/100

LINK/ACT

RX

TX

RX

TX

RESET

ETHERNET APPLICATION PORTS

SERIAL APPLICATION PORTS

ERR APP OK

10/100

LINK/ACT

CONFIG

10/100

LINK/ACT

RX

RX

TX

TX

RESET

ETHERNET APPLICATION PORTS

SERIAL APPLICATION PORTS

P1

P1

Competitive Network Migration/Modernization

AN-X2-AB-DHRIO Remote I/O EtherNet/IP™ Gateway Features• Replace old Remote I/O drives with new drives on EtherNet/IP™ without modifying PLC code

• Replace PanelView™ units on Remote I/O to new PanelView™ Plus 6 models on EtherNet/IP™ without modifying PLC code

• New controllers can utilize existing legacy Allen-Bradley® I/O

• Enables your Remote I/O PLC-5® or SLC™ to communicate with EtherNet/IP™ FLEX® I/O adapters, giving you a phased migration option when your 1794-ASB spares are gone

Remote I/O Migration and Modernization

AN-X(2) Family of Gateways

C/C++ Solutions

Features• Enables Allen-Bradley® PAC via EtherNet/IP™

to control I/O devices on legacy networks• Enables a phase-based approach for

migrating legacy control systems• Monitor mode enables testing & verification

of PAC logic before controlling I/O

Features• Ideal for custom algorithm applications

• Linux Virtual Machine (VM) and C/C++ development environment provided on separate DVD

• VM contains preinstalled toolchain and libraries

• VM contains the popular Eclipse IDE

• Multiple Ethernet & serial port example applications provided on VM

• Two independent Ethernet ports, and two independent serial ports (RS232/422/485)

1771 I/O

Allen-Bradley Remote I/O™

Blue Hose® EtherNet/IP™

CompactLogix™

CompactLogix L36ERMRUN

FORCE

I/O

OK

NS

LINK 1

LINK 2

SD

Allen-Bradley Remote I/O™

Blue Hose® EtherNet/IP™

PLC-5®EtherNet/IP™

I/O Block & Adapter

10 2 3 4 5 6 7

Allen-Bradley Remote I/O™

Blue Hose® EtherNet/IP™

PLC-5®

89

2

5

0

3

6

7

1

4

PowerFlex®

Modicon® S908Modicon® RIO Drop

TI Remote I/O

GENIUS GENIUS GENIUS

Genius® I/O Bus

Square D® I/O

Texas Instruments®RIO Rack

Genius® I/O Blocks

Honeywell® IPC 620 I/O

Honeywell® IPC-620 Serial I/O Bus

Fisher PROVOX® Control I/O

Moore APACS+ I/O

APACS+ I/O

PROVOX® Control Bus I/OControlLogix®

ACM

OKACTIVESECURITY

ACM

OKACTIVESECURITY

SDM+

OKACTIVE

ACM

OKACTIVESECURITY

SAM

OKACTIVE

ACM

OKACTIVESECURITY

OKACTIVE

SDM+

OK

PSM

EtherNet/IP™

SY/MAX I/O

Allen-Bradley Remote I/O™

DH+™ or EtherNet/IP™

PanelView™ PlusPLC-5®

Page 7: Communication Solutions for Rockwell Automation Users · PDF fileCommunication Solutions for Rockwell ... feature. With PDS, you don’t have to change your PC ... • Enables your

7www.prosoft-technology.com | For a list of our most popular in-chassis solutions and part numbers, see page 13; for gateways, page 14.

SLC™

PROFIBUS® Solutions

Features

• Remote configuration and diagnostics

• Solutions for PROFIBUS DP-V0 and PROFIBUS DP-V1

• Multi-Slave gateway solutions for large data transfers

• Support for PROFIBUS DP Master or PROFIBUS DP Slave connectivity

• Supports PA devices through third-party coupler

• DTM pass-thru support

ControlLogix®

CompactLogix™Gateways

CompactLogix L36ERMRUN

FORCE

I/O

OK

NS

LINK 1

LINK 2

SD

DIAG

PROFIBUS

SYS

COM

PROFIBUS® DP

DP/PA third-party couplerPROFIBUS® PA

Ethernet

CompactLogix™

AssetManagement

Software

IEC 61850 Gateway Features • Fast real-time data transfers with maximum of 10,000 bytes

in and 9,920 out (PLX82) or 5,000 bytes in, 4,960 out (PLX81)

• Polls up to 20 IEC 61850 server devices

• Application-specific Add-On Instructions are automatically generated

• IEC 61850 IED tags are created in your Studio 5000®/RSLogix 5000™ Project, reducing configuration time and errors

In-Chassis DNP3 Ethernet Module Features• Ethernet Client supports up to 40 DNP3 Ethernet

server devices such as RTUs, IEDs, and various protection relays

• Up to 20,000 points of data

• DNP3 Ethernet server allows the unit to interface to other client devices such as SCADA and DCS systems

DNP3 Ethernet

n

IEDs

2 31 4 5

ControlLogix®

SCADA/DCS

Energy SolutionsIEC 61850

IEC 61850

1 2 ...

EtherNet/IP™

SCADA/DCS

ETHERNET

RESET

ERR

FLT PWR

MS NS

CFG

LINK/ACT

100 Mbit

E1

RESET

CFG ERR

PWR

MS NS

FLT

LINK/ACT

ETH 1

100 Mbit

LINK/ACT

ETH 2

100 Mbit10.1.10.1 20.2.20.2

Client Gateway

Server Module

Page 8: Communication Solutions for Rockwell Automation Users · PDF fileCommunication Solutions for Rockwell ... feature. With PDS, you don’t have to change your PC ... • Enables your

8 www.prosoft-technology.com | For a list of our most popular wireless solutions and part numbers, see page 12; for in-chassis, page 13.

In-Chassis Flow Computers for Multi-Well Pad and LACT Applications

Features • Available for ControlLogix®, CompactLogix™ and

SLC™ platforms

• Supports 8-16 meter runs with 4 streams per meter run for the measurement of hydrocarbon gases and liquids

• Measurement standards supported: AGA 3, 7, 8 and API 2540

• Eliminates the need for RTUs and stand-alone flow computers

• Provides Modbus® slave capability for reporting of flow measurement values to SCADA or HMI system with Modbus TCP/IP supported on MVI56E-AFC

• MVI56E-AFC provides Enron Modbus for reporting of alarm, events and archive data to 3rd party systems, as well as support for Flow-Cal CFX files, and transmitter calibration functions in EAFC Manager software

Field I/O

CompactLogix™

AFC

CFG

P1App

CompactLogix L24ERQBFC1BRUN

FORCE

I/O

OK SD

LINK 2

LINK 1

NSCFGAPPBAT

P2P1BPOK

P2App

ERR OK

W & MLOCK

Adds stand-alone flow computer capabilities to the Rockwell Automation® PAC line

Features• Bi-directional

• 900 MHz or 2.4 GHz

Wireless I/OWhat would you monitor if you didn’t have to worry about the cost of running wire? Whether you need a point-to-point application or have many distributed I/O devices, our Wireless I/O solutions are a great alternative to running long wire runs. Eliminate running conduit, trenching or permitting. The system can be expanded as your I/O needs grow.

Multi PointPoint-Point

CompactLogix L36ERMRUN

FORCE

I/O

OK

NS

LINK 1

LINK 2

SD

COM

M A

DAPT

ER

ETH

1

P1

APP

P2

APP

Modbus

• Each radio can connect up to 16 I/O modules

• Available as Analog I/O 0-10 V, Analog I/O 4-20 mA & Digital/Discrete I/O

ControlLogix®SLC™

CompactLogix™

Page 9: Communication Solutions for Rockwell Automation Users · PDF fileCommunication Solutions for Rockwell ... feature. With PDS, you don’t have to change your PC ... • Enables your

9For a list of our most popular wireless solutions and part numbers, see page 12. | www.prosoft-technology.com

Features• IP67 water/dust rated

• Designed for extreme temperatures (-40° to +75° C), high vibration/shock & hazardous locations (UL C1D2, ATEX Zone 2)

• Power over Ethernet (PoE)

EtherNet/IP™I/O Block & Adapter

Drive

HMI

RepeaterServerControl Room

Access Point

Repeater Repeater

ControlLogix®

MIMO Antenna

MIMO AntennaMIMO

Antenna

89

2

5

0

3

6

7

1

4

10 2 3 4 5 6 7

ControlLogix®

VideoCamera

Serial

EtherNet/IP™

MIMO Antenna

Mobile Worker

Modbus® RTU(to Modbus TCP/IP Host)

802.11abgn Fast Industrial Hotspot

RLX2-IHNF

ANT AANT BANT C

POWER

RF TRANSMIT

RF REC

EIVE

SERIAL

ETHERNETNET

MOD

SIGNALSTRENGTH

802.11abgn Fast Industrial Hotspot

RLX2-IHNF

ANT AANT BANT C

POWER

RF TRANSMIT

RF REC

EIVE

SERIAL

ETHERNETNET

MOD

SIGNALSTRENGTH

802.11abgn Fast Industrial Hotspot

RLX2-IHNF

ANT AANT BANT C

POWER

RF TRANSMIT

RF REC

EIVE

SERIAL

ETHERNETNET

MOD

SIGNALSTRENGTH

802.11abgn Fast Industrial Hotspot

RLX2-IHNF

ANT AANT BANT C

POWER

RF TRANSMIT

RF REC

EIVE

SERIAL

ETHERNETNET

MOD

SIGNALSTRENGTH

CompactLogix™

COM

M A

DAPT

ER ETHP1P2

CFGBPOK

ETH

P1App

P2App

CompactLogix L36ERMRUN

FORCE

I/O

OK

NS

LINK 1

LINK 2

SD

802.11n (abgn) Fast Industrial HotspotsFeatures• Fast Roaming with under 10 ms switchover times maintains connections for moving machines/platforms

• High-speed 802.11n RF data rates up to 300 Mbps (MIMO and Channel Bonding)

• WPA/WPA2-Personal (PSK, AES and/or TKIP); WPA/WPA2-Enterprise (IEEE 802.1X/RADIUS, AES and/or TKIP)

• Quick configuration and advanced diagnostics with included IH Browser utility, embedded Web server and OPC Diagnostic Server

• Designed for extreme temperatures (-40° to +75° C), high vibration/shock and hazardous locations (UL Class 1, Div 2, ATEX Zone 2)

• Secure Digital configuration storage for quick field replacement

• Hotspots can be set up as Virtual Local Area Networks (VLAN) allowing for secure network segmentation

• EtherNet/IP embedded object and Modbus agent support lets users get radio diagnostics into their PAC/PLC, where the information can be analyzed and acted upon, helping to reduce downtime

802.11n Wireless Plant Architecture

2.4 GHz or 5 GHz High-Speed Wireless Network

Watertight Industrial Hotspots

Applications up to 2 mi/3.2 km

Applications up to 2 mi/3.2 km

Radiating Cable 2.4 & 5 GHz Band

Features• Special coaxial shield design uses slots to radiate RF Signals

• Optimized for 802.11g, 802.11a & 802.11n ProSoft Technology’s wireless LAN systems

• Wireless signal more stable in terms of response time – useful in communicating with I/O

• Used in metallic environments, rotating/spinning machines, conveyors, AGV, warehousing, etc

Page 10: Communication Solutions for Rockwell Automation Users · PDF fileCommunication Solutions for Rockwell ... feature. With PDS, you don’t have to change your PC ... • Enables your

10 www.prosoft-technology.com | For a list of our most popular wireless solutions and part numbers, see page 12.

802.11abg Industrial Hotspot

Features• Fast Roaming with under 10 ms switchover

times maintains connections for moving machines/platforms

• WPA/WPA2-Personal (PSK, AES and/or TKIP)

• WPA/WPA2-Enterprise (IEEE 802.1X/RADIUS, AES and/or TKIP)

• Quick configuration and advanced diagnostics with included IH Browser utility, embedded Web server and OPC Diagnostic Server

• Designed for extreme temperatures (-40° to +75° C), high vibration/shock and hazardous locations (UL Class 1, Div 2, ATEX Zone 2)

• Secure Digital configuration storage for quick field replacement

• RF compatible with existing RLXIB-IHW, IHG & IHA and RLX2-IHW, IHG, IHA & IHNF wireless networks

• EtherNet/IP embedded object and Modbus agent support lets users get diagnostics into their PAC/PLC, where the information can be analyzed and acted upon, helping to reduce downtime.

Features• High RF power for longer range

and coverage

• WPA/WPA2-Personal (PSK, AES and/or TKIP)

• WPA/WPA2-Enterprise (IEEE 802.1X/RADIUS, AES and/or TKIP)

• Fast Roaming (less than 10 ms)

• Quick configuration and advanced diagnostics with included IH Browser utility, embedded web server & OPC Diagnostic Server

• Designed for extreme temperatures (-40° to +75° C), high vibration/shock and hazardous locations (UL C1D2, ATEX Zone 2)

• Secure Digital configuration storage for quick field replacement

• EtherNet/IP embedded object and Modbus agent support lets users get diagnostics into their PAC/PLC, where the information can be analyzed and acted upon, helping to reduce downtime.

Access Point

SCADA

Client

Access Point

PanelView™ Plus 6

Mobile Worker

802.11abg Fast Industrial Hotspot

RLX2-IHW

ANTENNARXONLY

POWER

RF TRANSMIT

RF REC

EIVE

SERIAL

ETHERNETNET

MOD

SIGNALSTRENGTH

802.11abg Fast Industrial Hotspot

RLX2-IHW

ANTENNARXONLY

POWER

RF TRANSMIT

RF REC

EIVE

SERIAL

ETHERNETNET

MOD

SIGNALSTRENGTH

802.11abg Fast Industrial Hotspot

RLX2-IHW

ANTENNARXONLY

POWER

RF TRANSMIT

RF REC

EIVE

SERIAL

ETHERNETNET

MOD

SIGNALSTRENGTH

SLC™

FL

RUN

Allen-Bradley

FLT

BATT

FORCE

DH485

Modbus

RUN PROG

SLC 5/03 CPU

CompactLogix™CompactLogix™

COM

M A

DAPT

ER ETHP1

CFGBPOK

ETH

P1App

CompactLogix L24ERQBFC1BRUN

FORCE

I/O

OK SD

LINK 2

LINK 1

NS

COM

M A

DAPT

ER ETHP1P2

CFGBPOK

ETH

P1App

P2App

CompactLogix L36ERMRUN

FORCE

I/O

OK

NS

LINK 1

LINK 2

SD

ControlLogix®

Repeater

802.11abg Fast Industrial Hotspot

RLX2-IHW

ANTENNARXONLY

POWER

RF TRANSMIT

RF REC

EIVE

SERIAL

ETHERNETNET

MOD

SIGNALSTRENGTH

Repeater

Repeater

Access Point Mobile Worker

CompactLogix™

802.11abg Fast Industrial Hotspot

RLX2-IHA

ANTENNARXONLY

POWER

RF TRANSMIT

RF REC

EIVE

SERIAL

ETHERNETNET

MOD

SIGNALSTRENGTH

802.11abg Fast Industrial Hotspot

RLX2-IHA

ANTENNARXONLY

POWER

RF TRANSMIT

RF REC

EIVE

SERIAL

ETHERNETNET

MOD

SIGNALSTRENGTH

ControlLogix®

CompactLogix™

802.11abg Fast Industrial Hotspot

RLX2-IHG

ANTENNARXONLY

POWER

RF TRANSMIT

RF REC

EIVE

SERIAL

ETHERNETNET

MOD

SIGNALSTRENGTH

SCADA

COM

M A

DAPT

ER ETHP1

CFGBPOK

ETH

P1App

CompactLogix L24ERQBFC1BRUN

FORCE

I/O

OK SD

LINK 2

LINK 1

NS

COM

M A

DAPT

ER ETHP1P2

CFGBPOK

ETH

P1App

P2App

CompactLogix L36ERMRUN

FORCE

I/O

OK

NS

LINK 1

LINK 2

SD

802.11g and 802.11a High-Power Industrial Hotspots

Applications up to 5 mi/8 km

2.4 GHz or 5 GHz bands

2.4 GHz or 5 GHz bands

5GHz Applications up

to 5 mi/8 km2.4 GHz

Applications up to 10 mi/16 km

Page 11: Communication Solutions for Rockwell Automation Users · PDF fileCommunication Solutions for Rockwell ... feature. With PDS, you don’t have to change your PC ... • Enables your

11For a list of our most popular wireless solutions and part numbers, see page 12. | www.prosoft-technology.com

Industrial Cellular Gateway (M2M)

Features• Secure VPN access to remote

field devices over cellular networks

• Supports 3G GSM and CDMA

• Built-in Web server

• Embedded EtherNet/IP™ object allows your EtherNet/IP™ based processor to receive critical status data from your remote field devices

• GPS monitoring of mobile remote devices

Ethernet and Serial Frequency Hopping RadiosAvailable in 900 Mhz or 2.4 Ghz

Serial Features• Long-range, license-free wireless

communications for RS232 or RS485 devices

• Integrated Repeater Mode to extend range and work around obstructions

• ControlScape radio management software provides configuration and online diagnostics

Repeater/Remote

Master

Remote24 GHz SERIAL

INDUSTRIAL FREQUENCY HOPPING

BY PROSOFT TECHNOLOGY

POWER

RF TRANSMIT

LINK / RF RECEIVE

232 / 485

SIGNALSTRENGTH

Remote

24 GHz SERIAL

INDUSTRIAL FREQUENCY HOPPING

BY PROSOFT TECHNOLOGY

POWER

RF TRANSMIT

LINK / RF RECEIVE

232 / 485

SIGNALSTRENGTH

PLC-5®

MicroLogix™ 1000

Remote24 GHz SERIAL

INDUSTRIAL FREQUENCY HOPPING

BY PROSOFT TECHNOLOGY

POWER

RF TRANSMIT

LINK / RF RECEIVE

232 / 485

SIGNALSTRENGTH

SLC™

FL

RUN

Allen-Bradley

FLT

BATT

FORCE

DH485

Modbus

RUN PROG

SLC 5/03 CPU

CompactLogix™

ControlLogix®

OUT

IN

POWERRUNFAULTFORCE

24 GHz SERIAL

INDUSTRIAL FREQUENCY HOPPING

BY PROSOFT TECHNOLOGY

POWER

RF TRANSMIT

LINK / RF RECEIVE

232 / 485

SIGNALSTRENGTH

902-928 MHz

24 GHz SERIAL

INDUSTRIAL FREQUENCY HOPPING

BY PROSOFT TECHNOLOGY

POWER

RF TRANSMIT

LINK / RF RECEIVE

232 / 485

SIGNALSTRENGTH

Ethernet Features• Long-range, license-free

wireless communications for Ethernet devices

• Integrated Repeater Mode to extend range and work around obstructions

• Up to 1.1 Mbps RF data rate

• Smart Switch enables automatic peer-to-peer packet routing and optimizes RF performance

• ControlScape radio management software provides configuration and online diagnostics

Network-wide Access• HMI Data• PLC Programming• Diagnostics

HMI

Repeater/Remote

Master

SCADA

Remote

Remote

900-928 MHz or 2.4 GHz

CompactLogix™

ControlLogix®

CompactLogix™

Industrial Frequency Hopping

RLX2-IFH24E

ANTENNA

POWER

RF TRANSMIT

LINK / R

F REC

EIVE

232 /4

85

ETHERNET SIGNALSTRENGTH

DEFAULTSETTINGS

Industrial Frequency Hopping

RLX2-IFH24E

ANTENNA

POWER

RF TRANSMIT

LINK / R

F REC

EIVE

232 /4

85

ETHERNET SIGNALSTRENGTH

DEFAULTSETTINGS

Industrial Frequency Hopping

RLX2-IFH24E

ANTENNA

POWER

RF TRANSMIT

LINK / R

F REC

EIVE

232 /4

85

ETHERNET SIGNALSTRENGTH

DEFAULTSETTINGS

Industrial Frequency Hopping

RLX2-IFH24E

ANTENNA

POWER

RF TRANSMIT

LINK / R

F REC

EIVE

232 /4

85

ETHERNET SIGNALSTRENGTH

DEFAULTSETTINGS

CompactLogix™

Remote Site

3G/4G CellularGateway

Control Room

EngineeringWorkstationor SCADA

Firewall

Internet

PlantNetwork

3G/4GCellular Network

CompactLogix L24ERQBFC1BRUN

FORCE

I/O

OK SD

LINK 2

LINK 1

NS

PWR

NS

ERR

MS

SER

SERIAL

ENET

Cellular GatewayICX35-HWC+

ANT A

ANT B

WWAN

SIM

10-30 VDC6W MAX

Data is shared with any EtherNet/IP™-based controller, including signal strength, data usage, operating temperature and more.

4G LTE3G

Features• 4G LTE with fall-back to 3G

• Access to remote devices using secure VPN tunnels over Internet Connections

• Built-in Web server for local/remote configuration, monitoring and wireless network diagnostics

Page 12: Communication Solutions for Rockwell Automation Users · PDF fileCommunication Solutions for Rockwell ... feature. With PDS, you don’t have to change your PC ... • Enables your

12 www.prosoft-technology.com

Wireless Comparison Product Selection ChartProSoft Technology®M

odel

900

MHz

FH

Se

rial R

adio

900

MHz

FH

Ethe

rnet

Rad

io 2

.4 G

Hz F

H

Ethe

rnet

Rad

io80

2.11

abgn

W

eath

erpr

oof

Indu

stria

l Hot

spot

802.

11ab

gn

Fast

Indu

stria

l Ho

tspo

t

802.

11ab

g In

dust

rial

Hots

pot

802.

11g

Hi

gh-P

ower

In

dust

rial H

otsp

ot

802.

11a

Hi

gh-P

ower

In

dust

rial H

otsp

ot

Indu

stria

l Cel

lula

r Ga

tew

ays

Wire

less

I/O

RLX-

IFH9

SRL

X2-IF

H9E

RLX2

-IFH2

4ERL

X2-IH

NF-W

(C)

RLX2

-IHNF

RLX2

-IHW

RLX2

-IHG

RLX2

-IHA

ICX3

0-HW

CIC

X35-

HWC

BM-x

xx0-

RM1K

Feat

ures

& S

peci

ficat

ions

Devi

ce C

onne

ctiv

itySe

rial

Ethe

rnet

/Ser

ial

Ethe

rnet

/Ser

ial

Ethe

rnet

Ethe

rnet

/Ser

ial

Ethe

rnet

/Ser

ial

Ethe

rnet

/Ser

ial

Ethe

rnet

/Ser

ial

Ethe

rnet

/Ser

ial

Freq

uenc

y Ba

nd(s

)90

2-92

8 M

Hz90

0-92

8 M

Hz2.

4 GH

z2.

4 &

5 GH

z2.

4 &

5 GH

z2.

4 &

5 GH

z2.

4 GH

z5

GHz

Cellu

lar

Seve

ral f

requ

enci

es

avai

labl

e

Regi

ons

Unlic

ense

d

Use

Allo

wed

North

Am

erica

, La

tin A

mer

ica,

Aust

ralia

, New

Ze

alan

d

North

Am

erica

, La

tin A

mer

ica,

Aust

ralia

, New

Ze

alan

d

Glob

alGl

obal

Glob

alGl

obal

North

Am

erica

, La

tin A

mer

ica,

Austr

alia,

New

Ze

aland

, Midd

le Ea

st

North

Am

erica

, La

tin A

mer

ica,

Austr

alia,

New

Ze

aland

, Midd

le Ea

st

Glob

alGl

obal

Nort

h Am

eric

a,

Euro

pe, A

ustra

lia,

Mid

dle

East

Wire

less

Tech

nolo

gyFr

eque

ncy

Ho

ppin

gFr

eque

ncy

Hopp

ing

Freq

uenc

y Ho

ppin

gIE

EE 8

02.1

1abg

nIE

EE 8

02.1

1abg

nIE

EE 8

02.1

1abg

IEEE

802

.11g

IEEE

802

.11a

3G C

ellu

lar

HSUP

AEV

DO

4G L

TE

Cellu

lar

HSPA

Freq

uenc

y Ho

ppin

g

Max

Out

door

Ran

ge

(mile

s/km

)30

mi /

48

km30

mi /

48

km15

mi /

24

km2

mi /

3 km

2 m

i /3

km5

mi /

8 km

10 m

i / 1

6km

5 m

i / 8

km

Unlim

ited

1-4

mi /

1.6

-6.4

km

Fast

Roa

min

gN/

AN/

AN/

AYe

sYe

sYe

sYe

sYe

sN/

AN/

AN/

A

Repe

ater

Mod

eYe

sYe

sYe

sYe

sYe

sYe

sYe

sYe

sN/

AN/

AN/

A

Max

RF

Data

Rat

e23

0 kb

ps1.

1 M

bps

1.1

Mbp

s30

0 M

bps

300

Mbp

s54

Mbp

s54

Mbp

s54

Mbp

sN/

AN/

AN/

A

Secu

rity/

Encr

yptio

nPr

oprie

tary

FH

SS /

128

bit A

ES

Prop

rieta

ry

FHSS

/12

8 bi

t AES

Prop

rieta

ry

FHSS

/12

8 bi

t AES

802.

11i /

128

bit

AES

802.

11i /

128

bit

AES

802.

11i /

128

bit

AES

802.

11i /

128

bit

AES

802.

11i /

128

bit

AES

Inte

rnal

Fire

wal

lPr

oprie

tary

FHS

S /

128

bit A

ES

RF B

ased

IGM

P Qu

eryi

ngN/

AN/

AN/

AYe

sYe

sYe

sYe

sYe

sN/

AN/

AN/

A

Self-

Heal

ing

Netw

ork

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

N/A

N/A

N/A

Adva

nced

Dia

gnos

tics

(sig

nal s

treng

th L

EDs,

web

ser

ver,

netw

ork

man

agem

ent s

oftw

are,

OPC

ta

g se

rver

, SNM

P)

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

N/A

N/A

N/A

Haza

rdou

s Lo

catio

n Ap

prov

als

Clas

s 1,

Div

2Cl

ass

1, D

iv 2

Clas

s 1,

Div

2 /

Atex

Zon

e 2

Clas

s 1,

Div

2/At

ex Z

one

2 (W

C)Cl

ass

1, D

iv 2/

Ate

x Zo

ne 2

Clas

s 1,

Div

2/At

ex Z

one

2Cl

ass

1, D

iv 2/

Atex

Zon

e 2

Clas

s 1,

Div

2/At

ex Z

one

2Cl

ass

1, D

iv 2

Clas

s 1,

Div

2/ A

tex

Zone

2

Outd

oor/

Was

h Do

wn

Rate

d M

odel

N/A

N/A

N/A

IP67

N/A

N/A

N/A

N/A

N/A

N/A

N/A

Wire

less

App

licat

ions

Long

-Ran

ge S

CADA

Yes

Yes

Yes

N/A

N/A

N/A

Yes

Yes

Yes

Yes

N/A

Shor

t-Ra

nge

SCAD

AYe

sYe

sYe

sYe

sYe

sYe

sYe

sYe

sYe

sYe

sN/

A

Mob

ile W

orke

r (W

i-Fi)

N/A

N/A

N/A

Yes

Yes

Yes

Yes

Yes

N/A

Ethe

rNet

/IP™

Obj

ect

N/A

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

N/A

Ethe

rNet

/IP™

Impl

icit

Mes

sagi

ng (H

igh

Spee

d IO

)N/

AN/

AN/

AYe

sYe

sYe

sYe

sYe

sN/

AN/

AN/

A

Seria

l DF1

, ASC

II,

Mod

bus®

, DNP

3, e

tc.

Yes

Yes

(enc

apsu

latio

n)Ye

s (e

ncap

sula

tion)

N/A

Yes

(enc

apsu

latio

n)Ye

s (e

ncap

sula

tion)

Yes

(enc

apsu

latio

n)Ye

s (e

ncap

sula

tion)

N/A

N/A

N/A

Vide

oN/

ASn

apsh

ots

Only

Snap

shot

s On

lyFa

st F

ram

e Ra

teFa

st F

ram

e Ra

teYe

sYe

sYe

sYe

sYe

sN/

A

Page 13: Communication Solutions for Rockwell Automation Users · PDF fileCommunication Solutions for Rockwell ... feature. With PDS, you don’t have to change your PC ... • Enables your

13www.prosoft-technology.com

Platform ControlLogix® CompactLogix™ or MicroLogix™ 1500 FLEX® I/O SLC™ Point I/O

Protocol/Application

AGA/API Gas & Liquid Flow Computer MVI56E-AFC MVI69-AFC MVI46-AFC

Moore APACS+ I/O CLX-APACS

ASCII MVI56E-GSC MVI69-GSC MVI94-GSC-E MVI46-GSC

BASIC MVI56-BAS

BACnet®/IP PS56-BAS-406

BACnet® MS/TP PS56-BAS-073

‘C’ Programmable MVI56E-LDM MVI69E-LDM *

DF1 MVI56-DFCMMVI56-DFCMR

MVI69-DFCM MVI94-DFCM MVI46-DFCM

DNP3 Serial MVI56-DNP MVI69-DNP MVI94-DNP MVI46-DNP

DNP3 Ethernet MVI56-DNPSNETMVI56E-DNPNET

MVI69-DNPSNET MVI46-DNPSNET

EtherNet/IP™ MVI69-DFNT MVI46-DFNT

FA Control/Network MVI56E-FLN

Fisher PROVOX Control Bus I/O CLX-PVX

GE Ethernet Global Data MVI56-EGD MVI69-EGD

Generic Ethernet ASCII MVI56-GEC MVI69-GEC

HART® Multi-drop MVI56-HART MVI69-HART MVI46-HART

Honeywell® IPC-620 Serial I/O Bus CLX-422-IPC

IEC 60870-5-101 Slave MVI56-101S MVI69-101S MVI46-101S

IEC 60870-5-101 Master MVI56-101M MVI69-101M MVI46-101M

IEC 60870-5-104 Server MVI56-104S MVI69-104S MVI46-104S

IEC 61850 Server MVI56E-61850S

Limitorque Master MVI56-LTQ

LonWorks® PS56-LON-001

Modbus® Serial MVI56E-MCMMVI56E-MCMRMVI56E-MCMXT

MVI69E-MBS *MVI69L-MBS *

ILX34-MBS232 *ILX34-MBS485 *

MVI94-MCM MVI46-MCM ILX34-MBS232ILX34-MBS485

Modbus® Plus MVI56-MBP MVI46-MBP

Modbus® TCP/IP MVI56E-MNETMVI56E-MNETCMVI56E-MNETR

MVI56E-MNETCRMVI56E-MNETXT

ILX56-MM

MVI69E-MBTCP *MVI69L-MBTCP *

MVI46-MNETMVI46-MNETC

PROFIBUS® DP Master MVI56-PDPMV1 ILX69-PBM *MVI69-PDPMV1

PS69-DPM

MVI46-PDPMV1

PROFIBUS® DP Slave MVI56-PDPS ILX69-PBS *PS69-DPS

MVI46-PDPS

Siemens® 3964R MVI56-S3964R MVI69-S3964R MVI46-S3964R

Siemens® Industrial Ethernet ILX56-MMMVI56E-SIE

Johnson Controls Metasys® PS56-BAS-019

* CompactLogix™ ONLY

In-Chassis Product Selection ChartProSoft Technology®

Page 14: Communication Solutions for Rockwell Automation Users · PDF fileCommunication Solutions for Rockwell ... feature. With PDS, you don’t have to change your PC ... • Enables your

14 www.prosoft-technology.com

Prot

ocol

/App

licat

ion

Appl

icat

ion

/ Pro

toco

lAl

len-

Brad

ley

Rem

ote

I/O™

ASCI

I ‘C

’ Pro

gram

mab

le

Seria

l DF

1 M

aste

r/Sl

ave

DNP3

Ser

ial

DNP3

Eth

erne

tEt

herN

et/IP

™HA

RT®

Mul

ti-dr

op

(4 c

hann

els)

Alle

n-Br

adle

y Re

mot

e I/O

™56

01-R

IO-A

SCII

5601

-RIO

-DFC

M52

10-D

FNT-

RIO

AN-X

2-AB

-DHR

IO

ASCI

I56

01-R

IO-A

SCII

5102

-DFC

M-A

SCII3

PLX3

1-EI

P-AS

CII

PLX3

1-EI

P-AS

CII4

BACn

et®

/IPPS

-QS-

1010

-078

1 (2

50 P

oint

)PS

-QS-

1510

-078

1 (5

00 P

oint

)PS

-QS-

1010

-078

0 (2

50 P

oint

) PS

-QS-

1510

-078

0 (5

00 P

oint

)

BACn

et®

MS/

TPPS

-QS-

1010

-078

1 (2

50 P

oint

)PS

-QS-

1510

-078

1 (5

00 P

oint

)PS

-QS-

1010

-078

0 (2

50 P

oint

PS

-QS-

1510

-078

0 (5

00 P

oint

)

DF1

Mas

ter/

Slav

e56

01-R

IO-D

FCM

5102

-DFS

3-DF

M51

02-M

CM4-

DFCM

451

02-D

NPM

-DFC

M3

5102

-DNP

S-DF

CM3

5201

-DFN

T-DF

CM52

02-D

FNT-

DFCM

4

DH+™

AN-X

2-AB

-DHR

IO

DNP3

Ser

ial

5102

-DNP

M-D

FCM

351

02-D

NPS-

DFCM

352

01-D

FNT-

DNPM

5201

-DFN

T-DN

PS

DNP3

Eth

erne

t52

01-D

FNT-

DNPS

NET

5207

-DFN

T-HA

RT

Ethe

rNet

/IP™

5210

-DFN

T-RI

OAN

-X2-

AB-D

HRIO

PLX3

1-EI

P-AS

CII

PLX3

1-EI

P-AS

CII4

5201

-DFN

T-DF

CM52

02-D

FNT-

DFCM

452

01-D

FNT-

DNPM

5201

-DFN

T-DN

PS52

01-D

FNT-

DNPS

NET

GE G

eniu

sAN

-X2-

GENI

HART

® A

nalo

g51

08-D

FCM

-HAR

T (4

cha

nnel

s)52

08-D

FNT-

HART

(4 c

hann

els)

5228

-DFN

T-HA

RT (8

cha

nnel

s)

HART

® M

ulti-

drop

52

07-D

FNT-

HART

(4 c

hann

els)

IEC

6087

0-5-

101

Slav

e51

02-D

FCM

3-10

1S

IEC

6087

0-5-

104

Serv

er52

01-D

FNT-

104S

IEC

6185

0PL

X81-

EIP-

6185

0PL

X82-

EIP-

6185

0

LonW

orks

®PS

-QS-

1011

-078

3 (2

50 P

oint

)PS

-QS-

1511

-078

3 (5

00 P

oint

)PS

-QS-

1011

-078

3 (2

50 P

oint

)PS

-QS-

1511

-078

3 (5

00 P

oint

)51

07-M

CM-H

ART

Met

asys

® N

2PS

-QS-

1010

-078

2 (2

50 P

oint

) PS

-QS-

1510

-078

2 (5

00 P

oint

)PS

-QS-

1010

-078

2 (2

50 P

oint

) PS

-QS-

1510

-078

2 (5

00 P

oint

)53

07-M

BP-H

ART

Mod

bus®

Ser

ial

5601

-RIO

-MCM

5602

-RIO

-MCM

451

02-M

CM-A

SCII3

5102

-MCM

4-AD

M4

5102

-DNP

M-M

CM3

5102

-DNP

S-M

CM3

5201

-DNP

SNET

-MCM

5202

-DNP

SNET

-MCM

4PL

X31-

EIP-

MBS

PLX3

1-EI

P-M

BS4

52

07-M

NET-

HART

Mod

bus®

TCP

/IP52

10-M

NET-

RIO

5201

-MNE

T-AS

CII

5202

-MNE

T-AS

CII4

5202

-MNE

T-AD

M4

5201

-MNE

T-DF

CM52

02-M

NET-

DFCM

452

01-M

NET-

DNPM

5201

-MNE

T-DN

PS52

01-M

NET-

DNPS

NET

PLX3

1-EI

P-M

BTCP

PLX3

2-EI

P-M

BTCP

5507

-PDP

S-HA

RT

Mod

icon

S90

8AN

-X-M

OD

PROF

IBUS

® D

P56

05-R

IO-P

DPS

5105

-ASC

II-PD

PS51

04-D

FCM

PDP

M51

05-D

FCM

-PDP

S51

05-D

NPS-

PDPS

5205

-DNP

SNET

-PDP

S52

04-D

FNT-

PDPM

V152

05-D

FNT-

PDPS

AN-X

-PB

PROF

INET

®PL

X31-

EIP-

PND

PLX3

2-EI

P-PN

D

Siem

ens®

Indu

stria

l Eth

erne

tPL

X31-

EIP-

SIE

PLX3

2-EI

P-SI

E

Squa

re D

® R

emot

e I/

OAN

-X2-

SQD

Texa

s Ins

trum

ents

® R

emot

e I/O

AN-X

-TI

Stand-Alone Gateways Product Selection ChartProSoft Technology®

Page 15: Communication Solutions for Rockwell Automation Users · PDF fileCommunication Solutions for Rockwell ... feature. With PDS, you don’t have to change your PC ... • Enables your

15www.prosoft-technology.com

Stand-Alone Gateways Product Selection ChartProSoft Technology®Pr

otoc

ol/A

pplic

atio

n

Appl

icat

ion/

Prot

ocol

HART

®

Mul

ti-dr

op

(8 c

hann

els)

IEC

6087

0-5-

101

Slav

eIE

C 60

870-

5-10

4 Se

rver

Mod

bus®

Ser

ial

Mod

bus®

Plu

sM

odbu

s® T

CP/IP

PROF

IBUS

® D

P M

aste

rPR

OFIB

US®

DP

Sl

ave

PROF

INET

®Sq

uare

R

emot

e I/

O

Alle

n-Br

adle

y Re

mot

e I/O

™56

01-R

IO-M

CM

5602

-RIO

-MCM

452

10-M

NET-

RIO

5604

-RIO

-PDP

MVI

5605

-RIO

-PDP

S

ASCI

I51

02-M

CM-A

SCII3

5301

-MBP

-ASC

II53

02-M

BP-A

SCII4

5201

-MNE

T-AS

CII

5202

-MNE

T-AS

CII4

5105

-ASC

II-PD

PS

BACn

et®

/IPPS

-QS-

1010

-075

7 (2

50 P

oint

)PS

-QS-

1510

-075

7 (5

00 P

oint

)PS

-QS-

1010

-075

7 (2

50 P

oint

)PS

-QS-

1510

-075

7 (5

00 P

oint

)

BACn

et®

MS/

TPPS

-QS-

1010

-075

7 (2

50 P

oint

)PS

-QS-

1510

-075

7 (5

00 P

oint

)PS

-QS-

1010

-075

7 (2

50 P

oint

)PS

-QS-

1510

-075

7 (5

00 P

oint

)

DF1

Mas

ter/

Slav

e51

02-D

FCM

3-10

1S51

02-M

CM4-

DFCM

453

01-M

BP-D

FCM

5302

-MBP

-DFC

M4

5201

-MNE

T-DF

CM52

02-M

NET-

DFCM

451

04-D

FCM

-PDP

M51

05-D

FCM

-PDP

S

DNP3

Ser

ial

5102

-DNP

M-M

CM3

5102

-DNP

S-M

CM3

5301

-MBP

-DNP

S52

01-M

NET-

DNPM

5201

-MNE

T-DN

PS51

04-D

NPS-

PDPM

5105

-DNP

M-P

DPS

5105

-DNP

S-PD

PS

DNP3

Eth

erne

t52

01-D

NPSN

ET-M

CM

5202

-DNP

SNET

-MCM

452

01-M

NET-

DNPS

NET

5205

-DNP

SNET

-PDP

S

Ethe

rNet

/IP™

5201

-DFN

T-10

4SPL

X31-

EIP-

MBS

PLX3

1-EI

P-M

BS4

5303

-MBP

-DFN

TPL

X31-

EIP-

MBT

CPPL

X32-

EIP-

MBT

CP52

04-D

FNT-

PDPM

5205

-DFN

T-PD

PSAN

-X-P

BPL

X31-

EIP-

PND

AN-X

2-SQ

D

HART

® A

nalo

g52

08-M

NET-

HART

(4 c

hann

els)

5228

-MNE

T-HA

RT (8

cha

nnel

s)

HART

® M

ulti-

drop

(4

cha

nnel

s)51

07-M

CM-H

ART

5307

-MBP

-HAR

T52

07-M

NET-

HART

5507

-PDP

S-HA

RT

IEC

6087

0-5-

101

Slav

e51

02-M

CM3-

101S

5201

-MNE

T-10

1S51

05-1

01S-

PDPS

IEC

6087

0-5-

104

Serv

er52

01-1

04S-

MCM

52

02-1

04S-

MCM

453

03-M

BP-1

04S

5201

-MNE

T-10

4S

IEC

6185

0PL

X81-

MNE

T-61

850

PLX8

2-M

NET-

6185

0

LonW

orks

®PS

-QS-

1011

-015

4 (2

50 P

oint

)PS

-QS-

1511

-015

4 (5

00 P

oint

)PS

-QS-

1011

-015

4 (2

50 P

oint

)PS

-QS-

1511

-015

4 (5

00 P

oint

)

Met

asys

® N

2PS

-QS-

1010

-011

7 (2

50 P

oint

)PS

-QS-

1510

-011

7 (5

00 P

oint

)PS

-QS-

1010

-011

7 (2

50 P

oint

)PS

-QS-

1510

-011

7 (5

00 P

oint

)

Mod

bus®

Ser

ial

5127

-MCM

-HAR

T51

02-M

CM3-

101S

5201

-104

S-M

CM52

02-1

04S-

MCM

451

02-M

BS3-

MBM

5102

-MCM

4-DF

CM4

5301

-MBP

-MCM

5302

-MBP

-MCM

452

01-M

NET-

MCM

5202

-MNE

T-M

CM4

5104

-MCM

-PD

PMV1

5105

-MCM

-PDP

SPL

X31-

PND-

MBS

PLX3

1-PN

D-M

BS4

Mod

bus®

Plu

s53

03-M

BP-1

04S

5301

-MBP

-MCM

53

02-M

BP-M

CM4

5303

-MBP

-MNE

T53

04-M

BP-P

DPM

5305

-MBP

-PDP

S

Mod

bus®

TCP

/IP52

01-M

NET-

101S

5201

-MNE

T-10

4S52

01-M

NET-

MCM

52

02-M

NET-

MCM

453

03-M

BP-M

NET

5204

-MNE

T-PD

PM52

05-M

NET-

PDPS

PLX3

1-M

BTCP

-PND

PLX3

2-M

BTCP

-PND

PROF

IBUS

® D

P51

05-1

01S-

PDPS

5205

-104

S-PD

PS51

05-M

CM-P

DPS

5304

-MBP

-PDP

MV1

5305

-MBP

-PDP

S52

04-M

NET-

PDPM

V1

5205

-MNE

T-PD

PS

PROF

INET

®PL

X31-

PND-

MBS

PLX3

1-PN

D-M

BS4

PLX3

1-M

BTCP

-PND

PLX3

2-M

BTCP

-PND

Siem

ens®

Indu

stria

l Eth

erne

tPL

X31-

MBT

CP-S

IEPL

X32-

MBT

CP-S

IE

Page 16: Communication Solutions for Rockwell Automation Users · PDF fileCommunication Solutions for Rockwell ... feature. With PDS, you don’t have to change your PC ... • Enables your

www.prosoft-technology.com

Global Offices

© 2001–2016by ProSoft Technology, Inc.All rights reserved.

Asia Pacific

Regional OfficePhone: [email protected] spoken: Bahasa, Chinese, English, Japanese, Korean

North Asia (China, Hong Kong)Phone: [email protected] spoken: Chinese, English

Southwest Asia (India, Pakistan)Phone: [email protected] spoken: English, Hindi, Urdu

Pacific Rim (Australia, New Zealand)Phone: [email protected] spoken: English

Southeast Asia (Singapore, Indonesia, Philippines)Phone: [email protected] Languages spoken: English, Bahasa, Tamil

Northeast & Southeast Asia (Japan, Taiwan, Thailand, Vietnam, Malaysia)Phone: [email protected] spoken: English, Chinese, Japanese

Korea Phone: [email protected] spoken: English, Korean

Europe / Middle East / Africa

Regional OfficePhone: +33.(0)[email protected] spoken: French, English

Middle East & AfricaPhone: [email protected] spoken: Hindi, English

North Western Europe (UK, IE, IS, DK, NO, SE)Phone: +44.(0)[email protected] spoken: English

Central & Eastern Europe, FinlandPhone: [email protected] spoken: Polish, English

Russia & CISPhone: [email protected] spoken: Russian, English

Austria, Germany, SwitzerlandPhone: [email protected] spoken: English, German

BeNeLux, France, North AfricaPhone: +33(0)[email protected] spoken: French, English

Mediterranean CountriesPhone: [email protected] spoken: Italian, English

Latin America

Regional OfficePhone: [email protected] spoken: Spanish, English

BrazilPhone: [email protected] spoken: Portuguese, English

Mexico & Central AmericaPhone : [email protected] spoken: Spanish, English

Andean Countries (Venezuela, Colombia, Peru, Ecuador & Carribean)Phone: [email protected] spoken: Spanish, English

Southern Cone (Argentina, Bolivia , Chile, Paraguay & Uruguay)Phone: [email protected] spoken: Spanish, English

North America

Regional OfficePhone : [email protected] spoken: English, Spanish

CATALOG_RA_2016_EN