20
7/28/2019 Combined Heating, Power and Cooling http://slidepdf.com/reader/full/combined-heating-power-and-cooling 1/20 Thermax Ltd Combined Heating, Power and Cooling Multi Energy Absorption Chillers

Combined Heating, Power and Cooling

  • Upload
    82540

  • View
    225

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Combined Heating, Power and Cooling

7/28/2019 Combined Heating, Power and Cooling

http://slidepdf.com/reader/full/combined-heating-power-and-cooling 1/20

Thermax Ltd

Combined Heating, Power and Cooling

Mult i Energy Abso rp t ion Chi l l er s

Page 2: Combined Heating, Power and Cooling

7/28/2019 Combined Heating, Power and Cooling

http://slidepdf.com/reader/full/combined-heating-power-and-cooling 2/20

Thermax Ltd

Heat Recovery…

Cogeneration

Trigeneration

Page 3: Combined Heating, Power and Cooling

7/28/2019 Combined Heating, Power and Cooling

http://slidepdf.com/reader/full/combined-heating-power-and-cooling 3/20

Thermax Ltd

Components of Co/Tri-generation

POWER SIDE

• Gas Turbine / MTs

• IC Engines

• Steam Turbine

RECOVERY SIDE

• HRSG / EGB

• Absorption Chiller

Page 4: Combined Heating, Power and Cooling

7/28/2019 Combined Heating, Power and Cooling

http://slidepdf.com/reader/full/combined-heating-power-and-cooling 4/20

Thermax Ltd

COGENERATION

EXHAUST GASFROM GT/DG

STEAM/HOT WATER

EXHAUST GAS(TO STACK)

HRSGPOWER

GENEARATINGEQUIPMENT

Page 5: Combined Heating, Power and Cooling

7/28/2019 Combined Heating, Power and Cooling

http://slidepdf.com/reader/full/combined-heating-power-and-cooling 5/20

Thermax Ltd

TRIGENERATION

ABSORPTIONCHILLER

CHILLING UPTO41 F / (-) 22F

COOLING WATER HEATREJECTION AT 95 TO 105F

TO PROCESSHEATING

HRSGSTEAM

Page 6: Combined Heating, Power and Cooling

7/28/2019 Combined Heating, Power and Cooling

http://slidepdf.com/reader/full/combined-heating-power-and-cooling 6/20

Thermax Ltd

Thermax Product Offerings / Capabilities

Medium & High Temp Hot water driven chillers up to 3500 TR also available.1 TR = 1 ton of refrigeration = 3.51 kW = 12000 BTU/hr = 3024 kcal/hr

TYPE RANGE in TR(Tons)

COP HEAT INPUT

Single Stage Steam 50-3500 0.7 16.8 lb steam/hr/TR(Steam: 14 – 50 psig)

Two Stage Steam 50-3500 1.35 8.6 lb steam/hr/TR(Steam: 55-140 psig)

Low Temp Hot water 20-1380 0.75 3.2 gpm hot water/TR

(195/185 degF)

Direct Fired 50-1400 1.20 10,000 BTU/hr/TR

Multi- Energy 50-350050-1400 with firing

- Combination of two or moreheat sources

Page 7: Combined Heating, Power and Cooling

7/28/2019 Combined Heating, Power and Cooling

http://slidepdf.com/reader/full/combined-heating-power-and-cooling 7/20Thermax Ltd

3500 TR absorption chiller

Page 8: Combined Heating, Power and Cooling

7/28/2019 Combined Heating, Power and Cooling

http://slidepdf.com/reader/full/combined-heating-power-and-cooling 8/20

Thermax Ltd

Recognition & Testing Capability Awards and Recognition

2010Thermax Exhaust Driven chiller with 12%higher COP was awarded Runners upprize in “Innovative Product design”Category in Bry-Air National awards for excellence in HVAC & R.

2007Thermax Zero Deg C machine awarded Firstprize in ‘Most Innovative Product DesignCategory in HVAC’ in Bry -Air Awards.

2006Thermax exhaust and multi-energydriven Machine (Trigenie) awarded firstprize in „Most Innovative Product Design

Category in HVAC' in Bry-Air Awards.

2000Thermax low temperature hot water drivenmachine (Cogenie) awarded as the‘Environment Product of the Year', UK .

Thermax has a state-of-the-art test baycapable of testing various types of vapor absorption machines – steam driven, fuelfired, exhaust driven, hot water driven or acombination of these up to a capacity of 3500 TR.

Page 9: Combined Heating, Power and Cooling

7/28/2019 Combined Heating, Power and Cooling

http://slidepdf.com/reader/full/combined-heating-power-and-cooling 9/20

Thermax Ltd

Advantages of Multi-Energy chillers

• Lesser equipments for CHPC plant, better for cost, space, maintenance

• Single absorption chiller can work on any combination following: – Exhaust Gases – Hot water – Fuel: Gas/Oil – Steam

• Totally customized to meet customer’s requirements with optimum heatrecovery

• Back up firing option for cooling when prime mover is not operational

• Supplementary fuel firing option to meet higher cooling load thanpossible by heat recovery

Page 10: Combined Heating, Power and Cooling

7/28/2019 Combined Heating, Power and Cooling

http://slidepdf.com/reader/full/combined-heating-power-and-cooling 10/20

Thermax Ltd

Experience

Page 11: Combined Heating, Power and Cooling

7/28/2019 Combined Heating, Power and Cooling

http://slidepdf.com/reader/full/combined-heating-power-and-cooling 11/20

Thermax Ltd

References of CHPC Installations

Page 12: Combined Heating, Power and Cooling

7/28/2019 Combined Heating, Power and Cooling

http://slidepdf.com/reader/full/combined-heating-power-and-cooling 12/20

Thermax Ltd

California State University, Fullerton, USA – 4.5 MW Power, 2600 TR of Cooling

Exhaust gas

1 x 4.5 MW CAT Solar

Gas Turbine

2 x 1300 ton Exhaust gas FiredChillers with back up firing

Page 13: Combined Heating, Power and Cooling

7/28/2019 Combined Heating, Power and Cooling

http://slidepdf.com/reader/full/combined-heating-power-and-cooling 13/20

Thermax Ltd

IBM Data Center Syracuse University, NY, – 780kW Power, 300 TR of Cooling

Exhaust gas

12 x C65 Capstone

Micro - Turbine 2 x 150 TR Exhaust gas

Fired Chillers

Page 14: Combined Heating, Power and Cooling

7/28/2019 Combined Heating, Power and Cooling

http://slidepdf.com/reader/full/combined-heating-power-and-cooling 14/20

Thermax Ltd

Berlin Airport, Germany; 740 TR Cooling

2 MW CAT Engine

2 x 370 TR Exhaust FiredChillers

2600 KW of Cooling for the Airport

Exhaust gas

Page 15: Combined Heating, Power and Cooling

7/28/2019 Combined Heating, Power and Cooling

http://slidepdf.com/reader/full/combined-heating-power-and-cooling 15/20

Thermax Ltd

Lonjas Technologia, Barcelona – 1400 TR of Cooling

District Cooling

Exhaust gas

GE Jenbacher J 620 GSF-196; Power output 3353KW

Exhaust gas based chiller

Page 16: Combined Heating, Power and Cooling

7/28/2019 Combined Heating, Power and Cooling

http://slidepdf.com/reader/full/combined-heating-power-and-cooling 16/20

Thermax Ltd

ITPL, B ang alore CHPC Pro ject 19 MW pow er; 2400 ton Cool ing

5 Nos. HRUs

GENSETS

2400 ton cooling for Air - conditioning

7 MW WIL

3 MW WIL

3 MW WIL

3 MW WIL

3 MW CAT

19 MW Green Power for facility

EXHAUST

HT HOT

WATER

GENSET JACKET WATER

Hot watergenerator(standby)

EXHAUST

EXHAUST

EXHAUST

EXHAUST

G E N S E T J A C K E T W A T E R

1200 ton x 2 Nos SingleDouble Effect Vapor Absorption Chillers

Page 17: Combined Heating, Power and Cooling

7/28/2019 Combined Heating, Power and Cooling

http://slidepdf.com/reader/full/combined-heating-power-and-cooling 17/20

Thermax Ltd

Moser Baer, India - 34 MW Power; 6000 TR Cooling

21.5 MW (6000ton) of Coolingfor Air Conditioning

Jacket Water

Exhaust

Steam

EGB

Hot Water Chiller; 4x 500 ton and 1 x160 ton

Steam Chiller; 5 x800 ton

5 x 6 MW Wartsila Engines

Page 18: Combined Heating, Power and Cooling

7/28/2019 Combined Heating, Power and Cooling

http://slidepdf.com/reader/full/combined-heating-power-and-cooling 18/20

Thermax Ltd

Few More …………..• UCF, USA* : 1000 TR

• Ciputra Mall, Indonesia : 1000 TR

• Huainan Coalmines, China : 1400 TR

• Atlantic City, USA : 2000 TR

• Halmsted, Sweden : 1300 TR

• Egger, Austria : 1600 TR

• Videocon, India : 1800 TR

• Sun Pharma Limited, India : 750 TR

• Praful Overseas, India : 800 TR

*: Not installed yet

Page 19: Combined Heating, Power and Cooling

7/28/2019 Combined Heating, Power and Cooling

http://slidepdf.com/reader/full/combined-heating-power-and-cooling 19/20

Thermax Ltd

Thank You!

Page 20: Combined Heating, Power and Cooling

7/28/2019 Combined Heating, Power and Cooling

http://slidepdf.com/reader/full/combined-heating-power-and-cooling 20/20

Thermax Ltd

Contacts:

Piyush Patel

Thermax Inc.

21800, Haggerty Road, Suite 112,Northville, MI 48167

Off: 248 468 0541 Ext 700

Cell: 248 756 5398