www.flownex.com 1
Combined Cycle Power Plant
Introduction This case study demonstrates the modeling of a Combined Cycle (CC) power plant of a High Temperature Gas-Cooled Reactor (HTGR). The nuclear reactor is not modeled in detail as the focus of this case study is not on the reactor but on the CC Power Conversion Unit (PCU).
System Description The lay-out of the system is shown in Figure 1.
Figure 1: Layout of combined cycle power plant.
HTR
PT Comp
Process HX
IPT HPT LPT
Boiler
Reheater
Generator Generator
Condenser
IHX
900 C
852 C
540 C
539 C
223 C
381 C
484 kg/s
113 kg/s
173 kg/s 417 MW
323 MW
41 MW
160.6 MW56 MW
Thermal efficiency = 51 %
Rankine cycle Steam
Helium
20 % Helium 80 % Nitrogen
210 MW
www.flownex.com 2
The plant consists of three closed loops that are connected through two heat exchangers. The first loop is a helium loop that consists of a blower, a High Temperature Gas-Cooled Reactor (HTGR) and an intermediate heat exchanger (IHX). The second is a Brayton cycle that consists of a compressor, a turbine, an IHX and a steam generator. The working fluid for the Brayton cycle is a mixture of 20 percent helium and 80 percent nitrogen. In parallel over the IHX is another heat exchanger called the process heat exchanger that can supply heat to e.g. a sulphur iodine hydrogen production plant. The third is a bottoming Rankine cycle that consists of the following components: a steam generator, three steam turbines (high pressure, intermediate pressure and low pressure), condenser and two condensate pumps.
Objective of simulation The objective of the example is twofold. Firstly it is to predict the steady-state performance of the plant and secondly it is to investigate the behavior of the plant in a situation where the mass flow through the process heat exchanger changes from 0 to 70 kg/s during a 35 second period.
Flownex model
The Flownex model of the system is shown in Figure 2.
The reactor is modeled as a pipe with a specified constant exit temperature of 900 C. The reason why the reactor is not modeled in detail is that the focus of the simulation, as mentioned earlier, is not on the reactor but on the on the CC PCU.
Three controllers are used to control the speed of the helium blower and the two condensate pumps that form part of the Rankine cycle. The blower speed controller senses the IHX exit temperature and controls the speed so as to keep this temperature constant. The controller on the high pressure condensate pump attempts to keep the boiler exit temperature constant while the controller on the low pressure condensate pump attempts to keep the mass source at node 1 zero.
Description of simulation First a steady-state simulation was done and the results of this simulation was then used as initial conditions for a transient simulation. With the transient simulation the mass flow through the IHX was ramped up from 0 to 70 kg/s over a 35 second period.
Results
Figure 3 shows the variation in mass flow through the IHX, the helium loop and in the Rankine cycle with time. Interesting to note is that the mass flow in the helium loop increases as the IHX mass flow increases. The mass flow in the steam cycle, however, stays constant.
Figure 4 shows the variation in temperature at a few positions in the plant with time. The temperature stays mostly constant except at the exit of the IHX where the temperature increases drastically as the mass flow through the IHX increases. This is as expected.
www.flownex.com 3
26PT
27
1PT
10PT
20PT
2PT
32P
36PT
21M
37M
5
17
18
4
148
15
11 12
16
6
319
7
9 13
22
23 25
24
28 29
33
30
3435
31
3
8
11 1215
1619
20
21 24
23 26
29 31
33
34
3638FM
22
2FM
27FM
28FM
4
6
10
9
17
18
32
30
37
39
25
1
5
35
7
13
14
1
2
3
40
Figure 2: Flownex model of the Combined Cycle High Temperature Reactor Gas-Cooled Nuclear Power Plant.
Blower
Reactor
Blower speed controller
Compressor Turbine
HPT IPT
LPT Condenser
Pump
Pump
Pump speed controller
Steam generator Reheater
Helium loop
Brayton cycle (20 % helium, 80 % nitrogen)
Rankine cycle (steam)
Intermediate heat exchanger (IHX)
www.flownex.com 4
0
50
100
150
200
250
0 50 100 150 200 250
Time [s]
Mas
s flo
w [k
g/s]
E38 E35 E5
Figure 3: Variation in mass flow with time.
Conclusion Flownex was used to simulate a complex combined cycle power plant that produces both electricity and process heat. It was shown that with the appropriate control system the plant will operate stably as the mass flow through the process heat exchanger is increased from 0 to 70 kg/s. This case study also demonstrated Flownexs ability do handle a network with different types of fluids i.e. pure gasses, gas mixtures and two-phase fluid.
0
100
200
300
400
500
600
700
800
900
0 50 100 150 200 250
Time [s]
Tem
pera
ture
[C
]
N1 N2 N7 N10 N12 N35 N29
Figure 4: Variation in temperature at a few positions in the plant with time.
Helium loop
Rankine cycle
IHX
IHX exit temperature