U1-S1
DESIGN OF COMBINED FOOTING
Input datab=
: :Bearing
Capacityfy=fcu=cover=200kN/m2460N/mm235N/mm212mm50mm0.9
: :Re-distribution FactorType of Columncolumn dimensionLoadWorking
Loadultimate loadCx (m)
: : "x"Cy (m)
: : "y"l (m)
: :distance between columnsGk (KN)Qk (KN)Mx-x (KN.m)My-y (KN.m)N
(KN)Total load of columnsMx-x (KN.m) My-y (KN.m)N (KN)Total load of
columnscolumn
A0.40.2242.918.400.000.0261.300.000.0369.51.7702.7998.1 column
B0.40.2388.45300.000.0441.400.000.0628.60
structural plan of areaShape of basePosition of C.G.Depth of
footingWt. of base =Required Area=Povided Area=B (m)
: :widthL (m)
: :lengthZxx (m3)Zyy (m3)X1 (m)
: :Distance from column A to C.G.X2 (m)
: :Distance from column B to C.G.h (m)h actual (m)dmax (mm)dmin
(mm)Actual wt.of
base=70.27kN3.865m24.2m21.52.81.051.961.070.630.40.40034433240.32kN
ultimatecheck for stress below baseultimate stress below baseMx1+Mx20.0CasesCase 1: All columns are fully loadedCase 2 : Col. A(DL+LL)+Col.B(DL)Case 3 : Col. A(DL)+Col.B(DL+LL)Case 1 : All columns are fully loadedCase 2 : Col. A(1.4*DL+1.6*LL)+Col.B(DL)Case 3 : Col. A(DL)+Col.B(1.4*DL+1.6*LL)My1+My20.0"N/A+Mxx/Zxx+Myy/Zyy"237.6237.6N (KN)743.0690.0724.6998.100757.900871.500"N/A+Mxx/Zxx-Myy/Zyy"237.6237.6X (m)1.071.021.101.070.871.23M (KN.m)0.0032.49-20.530.00151.58-139.44Max. preasure (KN/m2)177180.9183.1Pmax237.64257.79136.36"N/A-Mxx/Zxx+Myy/Zyy"237.6Pmin237.64103.12278.64OK SAFEOK SAFEdesign stress237.6
Beam dimensionAnalysis dataRequiredNominal dia. ""Number of
barsProvideProvided steel Moment calculationsb (mm)h (mm)d=d'
(mm)davg (mm) M (kNm)V (kN)K=K'=Z (mm)mm2mm2mmmm2Design of
longitudinal reinforcementBottom steel 15004003445033865.60
: :from programat face of column161.000
: :from programat distance d from face of
column0.01060.156326.8459.34678012890481212@200mmnominalSteel
ArrangementTop steel 15004003445033869.60
: :from programlarge moment between
columns0.01120.156326.8487.3678012890481212@200mmnominal12lc
(m)3C/4 +9/4 d (m)As=D. distanceRequiredD.Ddia. ""Number of
barsProvideProvided steel 14X-Xmm2mmmmm2Design of transverse
reinforcementBottom steel
10004003325033858.90.01530.156315.40427.3452012556551212@225mmnominal160.750.92Distribute
the steel for all------steel at central
zone------12------------steel at both edges------12------------Top
steel
10004000000.00.00000.0000.000.0052012556551212@225mmnominalY-Y0.71.05Distribute
the steel for all------steel at central
zone------16------------check for shearPunching check for column
APunching check for column Bsteel at both
edges------16------------vmax=vc=AREApermeter of punchingpunching
S.F.punching S.S.vc=AREApermeter of punchingpunching S.F.punching
S.S.vc=0.312N/mm20.411N/mm21.75256.0mm-108.8KN-0.061N/mm20.251N/mm21.75256.0mm150.3KN0.085N/mm20.251N/mm2OK
SAFEOK SAFEOK SAFE
case1case2case3ABCX+3D0.40.4237.64257.79136.36CY+3D0.70.7
237.64103.12278.64
Punching checkpermeter of punchingpunching S.F.punching S.S.vc=5256.0mm590.1KN0.332N/mm20.255N/mm2INCREASE THE DEPTH
237.7180.5207.5
U2-S2
DESIGN OF COMBINED FOOTING
Input datab=
: :Bearing
Capacityfy=fcu=cover=200kN/m2460N/mm235N/mm216mm50mm0.9
: :Re-distribution FactorType of Columncolumn dimensionLoadWorking
Loadultimate loadCx (m)
: : "x"Cy (m)
: : "y"l (m)
: :distance between columnsGk (KN)Qk (KN)Mx-x (KN.m)My-y (KN.m)N
(KN)Total load of columnsMx-x (KN.m) My-y (KN.m)N (KN)Total load of
columnscolumn A0.40.226921.800.000.0290.800.000.0411.5Distance in
x-x1.6Distance in y-y0.151213.11730.2 column
B0.20.5785.2137.100.000.0922.300.000.01318.70
structural plan of areaShape of basePosition of C.G.Depth of
footingWt. of base =Required Area=Povided Area=B (m)
: :widthL (m)
: :lengthZxx (m3)Zyy (m3)X1 (m)
: :Distance from column A to C.G.X2 (m)
: :Distance from column B to C.G.h (m)h actual (m)dmax (mm)dmin
(mm)Actual wt.of
base=121.31kN6.672m27.04m22.23.22.583.751.220.380.50.45039237676.03kN0.110.04ultimatecheck
for stress below baseultimate stress below baseMx1+Mx20.0CasesCase
1: All columns are fully loadedCase 2 : Col. A(DL+LL)+Col.B(DL)Case
3 : Col. A(DL)+Col.B(DL+LL)Case 1 : All columns are fully
loadedCase 2 : Col. A(1.4*DL+1.6*LL)+Col.B(DL)Case 3 : Col.
A(DL)+Col.B(1.4*DL+1.6*LL)My1+My20.0"N/A+Mxx/Zxx+Myy/Zyy"245.8245.8N
(KN)1289.11152.01267.31730.2001196.7001587.700"N/A+Mxx/Zxx-Myy/Zyy"245.8245.8X
(m)1.221.171.241.221.051.33y(m)0.110.110.120.110.100.12Mx
(KN.m)0.000.00-11.910.0011.97-15.88My(KN.m)0.0053.80-23.830.00203.44-174.65Max.
preasure
(KN/m2)183.2178191Pmax245.77224.24172.80"N/A-Mxx/Zxx+Myy/Zyy"245.8Pmin245.77115.74265.94OK
SAFEOK SAFEdesign stress245.8
Beam dimensionAnalysis dataRequiredNominal dia. ""Number of
barsProvideProvided steel Moment calculationsb (mm)h (mm)d=d'
(mm)davg (mm) M (kNm)V (kN)K=K'=Z (mm)mm2mm2mmmm2Design of
longitudinal reinforcementBottom steel 220045039250384141.50
: :from programat face of column277.540
: :from programat distance d from face of
column0.01200.156372.4869.491128712121356121212@175mmnominalSteel
ArrangementTop steel 22004503925038449.70
: :from programlarge moment between
columns0.00420.156372.4305.40128712121356121212@175mmnominal12lc
(m)3C/4 +9/4 d (m)As=D. distanceRequiredD.Ddia. ""Number of
barsProvideProvided steel 14X-Xmm2mmmmm2Design of transverse
reinforcementBottom steel
100045037650384133.00.02690.156357.20852.0458512890481212@125mmrequired161.11.03Steel
arrangement is required904.321.676steel at central
zone904.3201.67612890481212@-25mmsteel at both
edges452.1600.52412445241212@-25mmTop steel
10004500000.00.00000.0000.000.0058512667861212@175mmnominalY-Y0.81.00Distribute
the steel for all------steel at central
zone------16------------check for shearPunching check for column
APunching check for column Bsteel at both
edges------16------------vmax=vc=AREApermeter of punchingpunching
S.F.punching S.S.vc=AREApermeter of punchingpunching S.F.punching
S.S.vc=0.322N/mm20.384N/mm22.15808.0mm-159.4KN-0.071N/mm20.242N/mm22.26008.0mm-607.7KN-0.263N/mm20.251N/mm2OK
SAFEOK SAFEOK SAFE
ABCX+3D0.20.4CY+3D0.50.5case1case2case3
245.77224.24178.95
245.77115.74272.10
Punching checkpermeter of punchingpunching S.F.punching S.S.vc=5808.0mm1214.7KN0.545N/mm20.264N/mm2INCREASE THE DEPTH
245.8170225.6
R3-O3
DESIGN OF COMBINED FOOTING
Input datab=
: :Bearing
Capacityfy=fcu=cover=200kN/m2460N/mm235N/mm212mm50mm0.9
: :Re-distribution FactorType of Columncolumn dimensionLoadWorking
Loadultimate loadCx (m)
: : "x"Cy (m)
: : "y"l (m)
: :distance between columnsGk (KN)Qk (KN)Mx-x (KN.m)My-y (KN.m)N
(KN)Total load of columnsMx-x (KN.m) My-y (KN.m)N (KN)Total load of
columnscolumn
R30.50.2578.1134.100.000.0712.200.000.01023.92.21369.31959.1 column
O30.50.2581.17600.000.0657.100.000.0935.20
structural plan of areaShape of basePosition of C.G.Depth of
footingWt. of base =Required Area=Povided Area=B (m)
: :widthL (m)
: :lengthZxx (m3)Zyy (m3)X1 (m)
: :Distance from column A to C.G.X2 (m)
: :Distance from column B to C.G.h (m)h actual (m)dmax (mm)dmin
(mm)Actual wt.of
base=136.93kN7.531m28m2242.675.331.051.150.50.45039438286.4kN
ultimatecheck for stress below baseultimate stress below baseMx1+Mx20.0CasesCase 1: All columns are fully loadedCase 2 : Col. A(DL+LL)+Col.B(DL)Case 3 : Col. A(DL)+Col.B(DL+LL)Case 1 : All columns are fully loadedCase 2 : Col. A(1.4*DL+1.6*LL)+Col.B(DL)Case 3 : Col. A(DL)+Col.B(1.4*DL+1.6*LL)My1+My20.0"N/A+Mxx/Zxx+Myy/Zyy"244.9244.9N (KN)1455.71379.71321.61959.1001605.0001513.300"N/A+Mxx/Zxx-Myy/Zyy"244.9244.9X (m)1.060.991.171.050.801.36M (KN.m)-13.6977.60-148.220.00401.25-469.12Max. preasure (KN/m2)184.6187.1193.1Pmax244.89275.91101.15"N/A-Mxx/Zxx+Myy/Zyy"244.9Pmin244.89125.34277.18OK SAFEOK SAFEdesign stress244.9
Beam dimensionAnalysis dataRequiredNominal dia. ""Number of
barsProvideProvided steel Moment calculationsb (mm)h (mm)d=d'
(mm)davg (mm) M (kNm)V (kN)K=K'=Z (mm)mm2mm2mmmm2Design of
longitudinal reinforcementBottom steel 200045039450388135.82
: :from programat face of column276.600
: :from programat distance d from face of
column0.01250.156374.3830.352117012111243111212@175mmnominalSteel
ArrangementTop steel 200045039450388110.00
: :from programlarge moment between
columns0.01010.156374.3672.50117012111243111212@175mmnominallc
(m)3C/4 +9/4 d (m)As=D. distanceRequiredD.Ddia. ""Number of
barsProvideProvided steel X-Xmm2mmmmm2Design of transverse
reinforcementBottom steel
100045038250388112.30.02200.156362.90708.1358512779171212@150mmrequired11.04Distribute
the steel for all------steel at central
zone------12------------1225steel at both
edges------12------------Top steel
10004500000.00.00000.0000.000.0058512667861212@175mmnominal14301635Y-Y11.23Distribute
the steel for all------steel at central
zone------0------------check for shearPunching check for column
APunching check for column B1840steel at both
edges------0------------vmax=vc=AREApermeter of punchingpunching
S.F.punching S.S.vc=AREApermeter of punchingpunching S.F.punching
S.S.vc=200.351N/mm20.384N/mm22.36056.0mm394.8KN0.168N/mm20.257N/mm22.36056.0mm306.1KN0.130N/mm20.257N/mm222OK
SAFEOK SAFEOK SAFE
case1case2case3ABCX+3D0.30.3244.89275.91101.15CY+3D0.60.6
244.89125.34277.18
Punching checkpermeter of punchingpunching S.F.punching S.S.vc=6056.0mm1403.4KN0.597N/mm20.250N/mm2INCREASE THE DEPTH
244.9200.7189.2
R5-O5
DESIGN OF COMBINED FOOTING
Input datab=
: :Bearing
Capacityfy=fcu=cover=200kN/m2460N/mm235N/mm212mm50mm0.9
: :Re-distribution FactorType of Columncolumn dimensionLoadWorking
Loadultimate loadCx (m)
: : "x"Cy (m)
: : "y"l (m)
: :distance between columnsGk (KN)Qk (KN)Mx-x (KN.m)My-y (KN.m)N
(KN)Total load of columnsMx-x (KN.m) My-y (KN.m)N (KN)Total load of
columnscolumn
R50.50.2946.1237.800.015.715.71183.900.0-22-22.01705.12.42163.83113.4
column O50.50.2798.1181.800.000.0979.900.000.01408.30
structural plan of areaShape of basePosition of C.G.Depth of
footingWt. of base =Required Area=Povided Area=B (m)
: :widthL (m)
: :lengthZxx (m3)Zyy (m3)X1 (m)
: :Distance from column A to C.G.X2 (m)
: :Distance from column B to C.G.h (m)h actual (m)dmax (mm)dmin
(mm)Actual wt.of
base=216.38kN11.901m212.5m22.555.2110.421.091.310.70.550494482165kN
ultimatecheck for stress below baseultimate stress below baseMx1+Mx20.0CasesCase 1: All columns are fully loadedCase 2 : Col. A(DL+LL)+Col.B(DL)Case 3 : Col. A(DL)+Col.B(DL+LL)Case 1 : All columns are fully loadedCase 2 : Col. A(1.4*DL+1.6*LL)+Col.B(DL)Case 3 : Col. A(DL)+Col.B(1.4*DL+1.6*LL)My1+My2-22.0"N/A+Mxx/Zxx+Myy/Zyy"251.2251.2N (KN)2328.82147.02091.03113.4002503.2002354.400"N/A+Mxx/Zxx-Myy/Zyy"247247X (m)1.090.971.221.090.771.44M (KN.m)0.00237.84-250.380.00801.02-824.04Max. preasure (KN/m2)187.9196.1192.9Pmax246.96270.80107.16"N/A-Mxx/Zxx+Myy/Zyy"251.2Pmin251.18121.27269.55OK SAFEOK SAFEdesign stress249.1
Beam dimensionAnalysis dataRequiredNominal dia. ""Number of
barsProvideProvided steel Moment calculationsb (mm)h (mm)d=d'
(mm)davg (mm) M (kNm)V (kN)K=K'=Z (mm)mm2mm2mmmm2Design of
longitudinal reinforcementBottom steel 250055049450488455.50
: :from programat face of column418.400
: :from programat distance d from face of
column0.02130.156469.32221.0401787.512202261201212@125mmrequiredSteel
ArrangementTop steel 25005504945048810.00
: :from programlarge moment between
columns0.00050.156469.348.761787.512161809161212@150mmnominallc
(m)3C/4 +9/4 d (m)As=D. distanceRequiredD.Ddia. ""Number of
barsProvideProvided steel X-Xmm2mmmmm2Design of transverse
reinforcementBottom steel
100055048250488179.10.02200.156457.90895.0471512890481212@125mmrequired1.251.26Distribute
the steel for all------steel at central
zone------12------------1225steel at both
edges------12------------Top steel
10005500000.00.00000.0000.000.0071512779171212@150mmnominal14301635Y-Y1.251.46Distribute
the steel for all------steel at central
zone------0------------check for shearPunching check for column
APunching check for column B1840steel at both
edges------0------------vmax=vc=AREApermeter of punchingpunching
S.F.punching S.S.vc=AREApermeter of punchingpunching S.F.punching
S.S.vc=200.339N/mm20.401N/mm23.37256.0mm792.5KN0.224N/mm20.255N/mm23.37256.0mm495.7KN0.140N/mm20.255N/mm222OK
SAFEOK SAFEOK SAFE
250460
case1case2case3ABCX+3D0.30.3246.96279.24107.16CY+3D0.60.6
251.18129.72269.55
Punching checkpermeter of punchingpunching S.F.punching S.S.vc=7256.0mm2299.7KN0.649N/mm20.251N/mm2INCREASE THE DEPTH
249.1200.3188.4
RING G-F-10
DESIGN OF COMBINED FOOTING
Input datab=
: :Bearing
Capacityfy=fcu=cover=200kN/m2460N/mm235N/mm212mm50mm0.9
: :Re-distribution FactorType of Columncolumn dimensionLoadWorking
Loadultimate loadCx (m)
: : "x"Cy (m)
: : "y"l (m)
: :distance between columnsGk (KN)Qk (KN)Mx-x (KN.m)My-y (KN.m)N
(KN)Total load of columnsMx-x (KN.m) My-y (KN.m)N (KN)Total load of
columnscolumn
A0.40.441812300.000.0541.000.000.0782.01.51093.01579.8 column
B0.40.442712500.000.0552.000.000.0797.80
structural plan of areaShape of basePosition of C.G.Depth of
footingWt. of base =Required Area=Povided Area=B (m)
: :widthL (m)
: :lengthZxx (m3)Zyy (m3)X1 (m)
: :Distance from column A to C.G.X2 (m)
: :Distance from column B to C.G.h (m)h actual (m)dmax (mm)dmin
(mm)Actual wt.of
base=109.30kN6.012m26.3m21.83.51.893.680.760.740.50.40034433260.48kN
ultimatecheck for stress below baseultimate stress below baseMx1+Mx20.0CasesCase 1: All columns are fully loadedCase 2 : Col. A(DL+LL)+Col.B(DL)Case 3 : Col. A(DL)+Col.B(DL+LL)Case 1 : All columns are fully loadedCase 2 : Col. A(1.4*DL+1.6*LL)+Col.B(DL)Case 3 : Col. A(DL)+Col.B(1.4*DL+1.6*LL)My1+My20.0"N/A+Mxx/Zxx+Myy/Zyy"250.8250.8N (KN)1153.51028.51030.51579.8001209.0001215.800"N/A+Mxx/Zxx-Myy/Zyy"250.8250.8X (m)0.760.660.850.760.530.98M (KN.m)0.0096.80-87.300.00278.07-267.48Max. preasure (KN/m2)183.1189.6187.3Pmax250.76267.47120.30"N/A-Mxx/Zxx+Myy/Zyy"250.8Pmin250.76116.34265.67OK SAFEOK SAFEdesign stress250.8
Beam dimensionAnalysis dataRequiredNominal dia. ""Number of
barsProvideProvided steel Moment calculationsb (mm)h (mm)d=d'
(mm)davg (mm) M (kNm)V (kN)K=K'=Z (mm)mm2mm2mmmm2Design of
longitudinal reinforcementBottom steel 180040034450338234.00
: :from programat face of column256.420
: :from programat distance d from face of
column0.03140.156326.81638.52293612151696151212@100mmrequiredSteel
ArrangementTop steel 18004003445033849.70
: :from programlarge moment between
columns0.00670.156326.8348.01936129101791212@200mmnominallc (m)3C/4
+9/4 d (m)As=D. distanceRequiredD.Ddia. ""Number of
barsProvideProvided steel X-Xmm2mmmmm2Design of transverse
reinforcementBottom steel
10004003325033865.60.01700.156315.40475.9552012556551212@225mmnominal0.91.07Distribute
the steel for all------steel at central
zone------12------------1225steel at both
edges------12------------Top steel
10004000000.00.00000.0000.000.0052012556551212@225mmnominal14301635Y-Y0.8751.05Distribute
the steel for all------steel at central
zone------0------------check for shearPunching check for column
APunching check for column B1840steel at both
edges------0------------vmax=vc=AREApermeter of punchingpunching
S.F.punching S.S.vc=AREApermeter of punchingpunching S.F.punching
S.S.vc=200.414N/mm20.477N/mm22.05656.0mm247.2KN0.129N/mm20.256N/mm22.05656.0mm263.0KN0.138N/mm20.256N/mm222OK
SAFEOK SAFEOK SAFE
case1case2case3ABCX+3D0.30.3250.76267.47120.30CY+3D0.60.6
250.76116.34265.67Punching checkpermeter of punchingpunching S.F.punching S.S.vc=5656.0mm1078.6KN0.564N/mm20.287N/mm2INCREASE THE DEPTH
250.8192193
RING-H5
DESIGN OF COMBINED FOOTING
Input datab=
: :Bearing
Capacityfy=fcu=cover=200kN/m2460N/mm235N/mm216mm50mm0.9
: :Re-distribution FactorType of Columncolumn dimensionLoadWorking
Loadultimate loadCx (m)
: : "x"Cy (m)
: : "y"l (m)
: :distance between columnsGk (KN)Qk (KN)Mx-x (KN.m)My-y (KN.m)N
(KN)Total load of columnsMx-x (KN.m) My-y (KN.m)N (KN)Total load of
columnscolumn A0.60.2939.427300.000.01212.400.000.01752.0Distance
in x-x0.9Distance in y-y0.151565.42253.2 column
B0.20.5318.234.800.000.0353.000.000.0501.20
structural plan of areaShape of basePosition of C.G.Depth of
footingWt. of base =Required Area=Povided Area=B (m)
: :widthL (m)
: :lengthZxx (m3)Zyy (m3)X1 (m)
: :Distance from column A to C.G.X2 (m)
: :Distance from column B to C.G.h (m)h actual (m)dmax (mm)dmin
(mm)Actual wt.of
base=156.54kN8.610m28.74m22.33.83.355.540.200.700.60.600542526125.86kN0.030.12ultimatecheck
for stress below baseultimate stress below baseMx1+Mx20.0CasesCase
1: All columns are fully loadedCase 2 : Col. A(DL+LL)+Col.B(DL)Case
3 : Col. A(DL)+Col.B(DL+LL)Case 1 : All columns are fully
loadedCase 2 : Col. A(1.4*DL+1.6*LL)+Col.B(DL)Case 3 : Col.
A(DL)+Col.B(1.4*DL+1.6*LL)My1+My20.0"N/A+Mxx/Zxx+Myy/Zyy"257.8257.8N
(KN)1691.31656.51418.32253.2002070.2001440.600"N/A+Mxx/Zxx-Myy/Zyy"257.8257.8X
(m)0.200.190.250.200.140.31y(m)0.030.030.040.030.020.05Mx
(KN.m)0.000.00-12.920.0020.70-28.81My(KN.m)0.0015.31-64.620.00124.21-158.47Max.
preasure
(KN/m2)193.6192.3177.8Pmax257.80259.29127.62"N/A-Mxx/Zxx+Myy/Zyy"257.8Pmin257.80214.44184.83OK
SAFEOK SAFEdesign stress257.8
Beam dimensionAnalysis dataRequiredNominal dia. ""Number of
barsProvideProvided steel Moment calculationsb (mm)h (mm)d=d'
(mm)davg (mm) M (kNm)V (kN)K=K'=Z (mm)mm2mm2mmmm2Design of
longitudinal reinforcementBottom steel 230060054250534141.50
: :from programat face of column277.540
: :from programat distance d from face of
column0.00600.156514.9628.857179412161809161212@125mmnominalSteel
ArrangementTop steel 23006005425053449.70
: :from programlarge moment between
columns0.00210.156514.9220.88179412161809161212@125mmnominal12lc
(m)3C/4 +9/4 d (m)As=D. distanceRequiredD.Ddia. ""Number of
barsProvideProvided steel 14X-Xmm2mmmmm2Design of transverse
reinforcementBottom steel
100060052650534143.00.01480.156499.70654.8678012779171212@150mmnominal161.151.37Distribute
the steel for all------steel at central
zone------12------------18steel at both
edges------12------------Top steel
10006000000.00.00000.0000.000.0078012779171212@150mmnominal20Y-Y0.951.33Distribute
the steel for all------steel at central
zone------16------------check for shearPunching check for column
APunching check for column Bsteel at both
edges------16------------vmax=vc=AREApermeter of punchingpunching
S.F.punching S.S.vc=AREApermeter of punchingpunching S.F.punching
S.S.vc=0.223N/mm20.372N/mm24.08008.0mm723.2KN0.169N/mm20.216N/mm23.87808.0mm-982.1KN-0.236N/mm20.230N/mm2OK
SAFEOK SAFEOK SAFE
ABCX+3D0.20.4CY+3D0.70.7case1case2case3
257.80259.29136.22
257.80214.44193.43
Punching checkpermeter of punchingpunching S.F.punching S.S.vc=8008.0mm1230.2KN0.288N/mm20.221N/mm2INCREASE THE DEPTH
257.9236.9164.9
out put table
GRADUATION PROJECT IN DESIGN OF REINFORCEMENT CONCRETE STRUCTURE
Table , Design of Combined Footings
Name of footingPlain Area of Footing R.C.C. Area of FootingBottom ReinforcementTop Reinforcementb (m)L (m)h (m)b (m)L (m)h (m)Long Direction (B1)Short Direction (B2)Long Direction (T1)Short Direction (T2)
F91.62.90.11.52.80.4012@200mm12@225mm12@[email protected]@100mm12@225mm12@[email protected]@175mm12@125mm12@[email protected]@125mm12@150mm12@[email protected]@175mm12@150mm12@[email protected]@125mm12@125mm12@150mm12@150mm