18
Consultants: 300 Marconi Boulevard Columbus OH 43215 schooleycaldwell.com 614-628-0300 614-628-0311 T F Drawing Issue Dates Bidding Prepared For: 8/24/2017 11:30:15 AM C:\RevitLocal\17220_CML Additional Services_v2016_ldunfield.rvt Columbus Metropolitan Library - Miscellaneous Renovations 96 South Grant Avenue Columbus, OH 43215 08.08.2017 Cover Sheet G000 17220 Aug 15, 2017 Columbus Metropolitan Library - Miscellaneous Renovations 96 South Grant Avenue Columbus, OH 43215 Columbus Metropolitan Library Revision Schedule Revision # Revision Description Revision Date

Columbus Metropolitan Library - Miscellaneous Renovations...CL / Center Line CLG Ceiling CLR Clear CMU Concrete Masonry Unit CO Clean Out COL Column COMP Composition/ Composite CONC

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Columbus Metropolitan Library - Miscellaneous Renovations...CL / Center Line CLG Ceiling CLR Clear CMU Concrete Masonry Unit CO Clean Out COL Column COMP Composition/ Composite CONC

Consultants:

300 Marconi BoulevardColumbus OH 43215schooleycaldwell.com

614-628-0300614-628-0311

TF

Drawing Issue Dates

BiddingPrepared For:

8/24

/201

7 11

:30:

15 A

M

C:\R

evitL

ocal

\172

20_C

ML

Add

ition

al S

ervi

ces_

v201

6_ld

unfie

ld.r

vt

ColumbusMetropolitanLibrary -MiscellaneousRenovations96 South Grant AvenueColumbus, OH 43215

08.08.2017

Cover Sheet

G00017220

Aug 15, 2017

Columbus Metropolitan Library - Miscellaneous Renovations96 South Grant Avenue Columbus, OH 43215

ColumbusMetropolitan

Library

Revision Schedule

Revision#

RevisionDescription

RevisionDate

Page 2: Columbus Metropolitan Library - Miscellaneous Renovations...CL / Center Line CLG Ceiling CLR Clear CMU Concrete Masonry Unit CO Clean Out COL Column COMP Composition/ Composite CONC

Symbols

Point Elevation

Existing Contours

New Contours

Property / Boundary Line

Match Line

Column Grid

Room Number & Name

Door Number

Window / Louver Type

Use letters in horizontal directionUse numbers in vertical direction

See door schedule in A600 series

See window & louver schedules in A600 series

See partition schedule in A000 seriesPartition Type

Datum Point

Building Section

North Arrow

1/A101

1

A101

1SIM

000B

0

Exst Basement

ROOM

Base Finish

Floor Finish

Wall Finish

1 /A101

1

A101

SIM

XX-XX-XX

0

A

1

SITE

ARCHITECTURAL

E-1

Detail numberSheet number

Wall Section1

A101

SIM

Detail numberSheet number

1

A101

SIM- - - -

- -

ElevationDetail numberSheet number

- -Detail

Detail numberSheet number

Revision Mark

Coded Note

Alternate Tag

Photograph Call-out

Finish Tag

Center Line

130

130

MATCH LINE

+481.0

Material Indications

Earth

Gravel fill

Concrete

Concrete Block

Brick (section)

Marble

Rough wood

Finish wood (section)

Plywood

Metal 1/2" and larger

Metal 1/2" and smaller

Rigid insulation

Plaster

Gypsum Board

Existing Construction, U.N.O.

Brick (elevation)

1. All dimensions shall be verified at the job by the General Contractor and each Sub-Contractor and theArchitect must be notified of any discrepancies before proceeding with the work.

2. All dimensions are to the face of finish, face of concrete, face of masonry, to centerlines of columns andother grid points, and to centerlines of doors and other scheduled openings unless otherwise noted.

3. Offset studs and/or shim as required to align finish material.

4. All vertical elevations and working points are given with reference to level one finish floor elevation 100'-0"datum.

5. The drawings are the graphic portion of the contract documents showing the design, location, anddimensions of the work. Do not scale the drawings to determine a dimension in question, consult thearchitect for clarification.

6. Contractor(s) are to investigate and verity location, condition, and capacity of all existing utilities within thelimits of work, prior to beginning construction. See site utility, mechanical and electrical drawings for furtherinformation.

7. The structure is designed to be self-supporting and stable after the building is fully completed. It is solelythe contractor(s) responsibility to determine erection procedures and sequences and to ensure the safetyof the building and its component parts during erection, including the addition of shoring, sheathing,temporary enclosure, etc. It is the contractor(s) sole responsibility to follow all applicable safety andconstruction regulations, ordinances and codes during the course of construction.

REMODELING NOTES

1. The coursing of all masonry to match that in existing building.

2. Fill any masonry voids with mortar or concrete where anchors occur.

3. Provide lintels over all openings including those req'd for ductwork, pipes, louvers, grilles, dampers, etc.

4. Coordinate locations and/or elevations of floor drain, registers, access panels, grilles, louvers, convectors,cabinet unit heaters, panels, etc., with mechanical and electrical contractors. Size and location of all flooropenings to be verified with trade affected before proceeding with work.

5. Bolting of wood to structural members or masonry shall be in general with a minimum of 1/2" bolts @ 4'-0"O.C. except where shown otherwise. Situations requiring special bolting shall be with the size andspacing of bolts to suit the conditions.

6. In any room in which plumbing, heating, or electrical alterations are made: the General Contractor shallmake proper repairs to other building items affected; i.e. floors, walls, ceilings, base, chair rail, trim, etc. Ingeneral, new materials and materials for repair conditions shall match similar items in quality, detail, profileand finish as those already built into the work.

7. All shaded walls appearing on reflected ceiling plans are to extend to underside of structure above.

8. All walls of all rooms with exposed structure ceilings to extend and seal to the structure.

General Notes

CODE DATA - 2011 OHIO BUILDING CODE

PROJECT SUMMARY:

- RECONFIGURE FIRST FLOOR BUILDING ENTRY FROM GARAGE- REVISE ELEVATORS 'E' & 'F' AND THEIR RESPECTIVE ELEVATORLOBBIES- SECOND FLOOR CONFERENCE ROOM KITCHEN AND RESTROOMREVISIONS- EXTERIOR SIGN MODIFICATIONS

2011 OHIO BUILDING CODE:

USE AND OCCUPANCY CLASSIFICATION:OBC 506.4.1: MIXED-USE NON-SEPARATED

OBC 303.1: A-3, ASSEMBLY (OFFICES ON SEVENTH FLOOR AND TOWER ROOF)OBC 304.1: B, BUSINESS (OFFICES ON FIRST AND SECOND FLOORS)OBC 311.2: S-1, MODERATE-HAZARD STORAGE (INCIDENTIAL ACCESSORY OCC.)OBC 311.3: S-2, LOW-HAZARD STORAGE

A-3 CONTROLS HEIGHT, AREA AND FIRE PROTECTION FOR ENTIRE BUILDING

SPECIAL DETAILED REQUIREMENTS BASED ON USE AND OCCUPANCY:

OBC 406.2: PARKING GARAGES

GENERAL BUILDING HEIGHTS AND AREAS:OBC TABLE 503: ALLOWABLE HEIGHT:

TYPE I-B CONSTRUCTION11 STORIES ALLOWABLE AND 160' HEIGHT4 STORIES ACTUAL AND 64'-6" HEIGHTUNLIMITED SF PER FLOOR ALLOWABLE

ZONING:

FLOOD ZONE:

FIRE CODE:

FOOD SAFETY:

BUILDING CODE:ACCESSIBILITY:ENERGY CODE:

ELECTRICAL CODE:

MECHANICAL CODE:

PLUMBING CODE:

ELEVATOR CODE:

Additional Referenced Standards frequently requested are as follows:

NFPA 13 – Standard for the Installation of Sprinkler Systems (2010 edition)NFPA 14 – Installation of Standpipe and Hose System (2010 edition)NFPA 72 – National Fire Alarm and Signaling Code (2010 Edition)

City of Columbus – Title 33Base Zoning:Parcel ID’s:

Flood Zone X – F.E.M.A. Map Number 39049C0328K – (June 17, 2008)

OAC 1301-7:7

OAC 3717-1

OAC 4101:1 (1-35)OAC 4101:1 (11)OAC 4101:1 (13)

OAC 4101:1 (27)

OAC 4101:2 (1-15)

OAC 4101:3 (1-13)

OAC 4101:5 (1,3)

1532-2013 (8/14/2013) DD - Downtown District010-066783-00010-190123-00010-285106-80

2011 – Ohio Fire Code (2009 IFC with Ohio amendments)

Ohio Uniform Food Safety Code (No effective date given)

2011 – Ohio Building Code (2009 IBC with Ohio amendments)2011 –OBC Chapter + 11 ICC / ANSI A 117.12009 – International Energy Conservation Code or ASHRAE90.1 (2007)2011 – National Electric Code NFPA 70-11

2011 – Ohio Mechanical Code (2009 IMC with Ohioamendments)2011 – Ohio Plumbing Code (2009 IPC with Ohio amendments)

2011 – Ohio Elevator Code (ASME A 17.1 2010)

APPLICABLE CODES:

FIRE PROTECTION SYSTEMS:OBC 903.3.1.1: NFPA 13 SPRINKLER SYSTEM INSTALLED (PARTIAL)OBC 907.2: NFPA 72 MANUAL AND AUTOMATIC FIRE ALARM SYSTEMOBC 907.2.1: AUTOMATIC FIRE ALARM SERVING GROUP AOBC 907.2.2: AUTOMATIC FIRE ALARM SERVING GROUP B

ACCESSIBILITY:OBC 1106.1: PARKING SPACES PROVIDED: 382

7 REQUIRED ACCESSIBLE PARKING SPACES (2 VAN)10 PROVIDED ACCESSIBLE PARKING SPACES INCLUDED (5 VAN)

MIXED USE AND OCCUPANCY:OBC 508.4: SEPARATION BETWEEN A-3 AND B USE: 1-HOUR

SEPARATION BETWEEN A-3 AND S-1 USE: 1-HOURSEPARATION BETWEEN A-3 AND S-2 USE: 1-HOURSEPARATION BETWEEN B AND S-1 USE: 1-HOURSEPARATION BETWEEN B AND S-2 USE: 1-HOURSEPARATION BETWEEN S-1 AND S-2 USE: 1-HOUR

RATED PARTITIONS ON CODE DATA PLANS ARE A COMBINATION OF NEWAND EXISTING CONSTRUCTION.

TYPE OF CONSTRUCTION:OBC TABLE 601:

TYPE I-B CONSTRUCTIONSTRUCTURAL FRAME: 2-HOURSBEARING WALLS, EXTERIOR: 2-HOURSBEARING WALLS, INTERIOR: 2-HOURSNON-BEARING WALLS AND PARTITIONS: 0-HOURFLOOR CONSTRUCTION: 2-HOURSROOF CONSTRUCTION: 1 1/2-HOURS

Consultants:

300 Marconi BoulevardColumbus OH 43215schooleycaldwell.com

614-628-0300614-628-0311

TF

Drawing Issue Dates

Bidding

8/24

/201

7 11

:30:

24 A

MC

:\Rev

itLoc

al\1

7220

_CM

L A

dditi

onal

Ser

vice

s_v2

016_

ldun

field

.rvt

ColumbusMetropolitanLibrary -MiscellaneousRenovations96 South Grant AvenueColumbus, OH 43215

08.08.2017

Index, Symbols, &Abbreviations

G00117220

Aug 15, 2017

& AndAngle

@ AtDiameterElectrical Phase

# Pound(s)

AB Anchor BoltABV AboveAC Asphaltic ConcreteA/C Air ConditioningACT Acoustic Ceiling TileAD Area DrainADD'L AdditionalADJ AdjacentA/E Architect And/ Or EngineerAFF Above Finished FloorAFS Automatic Fire SprinklerALUM AluminumALT AlternateANG AngleANOD AnodizedAOR Architect of RecordARCH ArchitecturalASPH Asphalt

B/ Bottom ofBD BoardBITUM BituminousBLDG BuildingBLKG BlockingBM BeamBOF Bottom of FootingBOJ Bottom of JoistBOS Bottom of SteelBOT BottomBRCG BracingBRG BearingBSMT BasementBU Built-Up

C CenterC/C Center to CenterCAB CabinetCB Catch BasinCD Cup DispenserCEM CementCER CeramicCI Cast IronCJ Control JointCJT Construction JointCL / Center LineCLG CeilingCLR ClearCMU Concrete Masonry UnitCO Clean OutCOL ColumnCOMP Composition/ CompositeCONC ConcreteCONT ContinuousCONSTR ConstructionCONTR ContractorCOORD CoordinateCRS CourseC.R.S. Cold Rolled SteelCSK CountersunkCT Ceramic TileCTR CenterCU FT Cubic FootCU YD Cubic YardCW Cold Water

DEMO DemolishDET DetailDF Drinking FountainDIA DiameterDIM DimensionDIV DivisionDL Dead LoadDP Deep, DepthDR DoorDS Down SpoutDWG DrawingDWL Dowel

EA EachE.C. Electrical ContractorE.E. Each EndE.F. Each FaceEJ Expansion JointEL ElevationELEC ElectricalEMBD EmbedmentENCL EnclosureEPB Electrical Panel BoardEQ EqualE.S. Each SideE.W. Each WayEWH Electrical Water HeaterEXH ExhaustEXIST ExistingEXP Expansion or ExposedEXP BT Expansion BoltEXT Exterior

FA Fire AlarmFDTN FoundationFD Floor DrainFDN FoundationFE Fire Extinguisher.FEC Fire Extinguisher CabinetF.F. Finished FloorFF EL Finish Floor ElevationFH Fire HydrantFHC Fire Hose CabinetFIN FinishFLR FloorFLR SK Floor SinkFOC Face of ConcreteFO Finish OpeningFOF Face of FinishFOM Face of MasonryFOS Face of StudFRMG FramingFTG Footing

GA GaugeGALV GalvanizedGB Grab BarG.C. General ContractorGLZ GlazingGLZ CMU Glazed Concrete Masonry UnitGR SF Gross Square FeetGYP Gypsum

HB Hose BibbHC Hollow CoreHCP / HCPD HandicappedHDR HeaderHDW HardwareHDWD HardwoodHM Hollow MetalHOR. / HORIZ HorizontalHP High PointHSB High Strength BoltHSS Tube SteelHT HeightHVAC Heating/Ventilating/Air ConditioningHW Hot Water

ID Inside DiameterINSUL InsulationINT InteriorINV InvertIP Iron PipeIPS Iron Pipe Size

JAN CLO Janitor's ClosetJ-BOX Junction BoxJT JointJS Janitor's Sink

KOP Knock Out PanelKPL Kick Plate

LAM LaminateLAV LavatoryLB / Lbs. Pound(s)LG LongLH Left HandLL Live LoadLLH Long Leg HorizontalLLV Long Leg VerticalLPT Low PointLT WT Light Weight

MATL MaterialMAX MaximumMB Machine BoltM.C. Mechanical ContractorMECH MechanicalMFR Manufacturer / SupplierMH ManholeMIN MinimumMO Masonry OpeningMS Machine ScrewMTL MetalMULL Mullion

NA / N/A Not ApplicableNIC Not in ContractNO / # NumberNOM NominalNRC Noise Reduction CoefficientNTS Not to Scale

O.C. On CenterOD Outside DiameterOH / OPH Opposite HandOPNG OpeningOPP OppositeOz Ounce

P.C. Plumbing ContractorP.L. PlatePL / Property LinePLAM Plastic LaminatePLAS PlasterPLGL Plate GlassPLYWD PlywoodPNL PanelPOL PolishedPR PairPSF Pounds per Square FootPSI Pounds per Square InchPTD Paper Towel DispenserP.T. PointPT / PTD Paint / PaintedPVC Poly Vinyl Chloride

QT Quarry Tile

R RadiusR RiserRA Return AirRCP Reinforced Concrete PipeRCP Reflected Ceiling PlanRD Roof DrainREBAR Reinforcing Steel BarsREC RecessedREINF Reinforced / ReinforcingREQD RequiredRESIL ResilientREST Rest RoomREV RevisionRHMS Round Head Machine ScrewRM RoomRO Rough OpeningROW Right of WayRWL Rain Water Leader

SC Solid CoreSCD Seat Cover DispenserSCHED ScheduleSD Storm DrainSECT SectionSF Square FeetSHT SheetSHTHG SheathingSHV ShelvingSIM SimilarSM Sheet MetalSND Sanitary Napkin DispenserS.O.G. Slab On GradeSPC SpacingSPEC SpecificationsSQ SquareSS Service SinkSST Stainless SteelSTD StandardSTIFF StiffenerSTL SteelSTOR StorageSTR StairSTRUCT StructuralSUSP SuspendedSYM Symmetrical

T TreadT/ Top of (T/STL, T/CONC)TB Towel BarTD Towel DispenserTDR Towel Dispenser/ReceptacleTEL TelephoneT&G Tongue and GrooveTHK ThicknessTHRES ThresholdTHRU ThroughTOC Top of ConcreteTOM Top of MasonryTOS Top of SteelTPH Toilet Paper HolderTR Trench (FTG)TYP Typical

UNO Unless Noted OtherwiseUR Urinal

V / VERT VerticalVB Vinyl BaseVCT Vinyl Composition TileVIF Verify in Field

W/ WithWC Water ClosetWD WoodWF Wide FlangeWGL Wire GlassW/O WithoutWP Working PointWR Water RepellentWS Weather StrippingWSCT WainscotWWF Welded Wire Fabric

∅ɸ

Abbreviations Drawing Index

01 - GeneralG000 Cover SheetG001 Index, Symbols, & Abbreviations

02 - ArchitecturalA101 P1.5, P2.5, P3.5, P4.5 & F1 Floor PlansA102 2nd Floor Carnegie - Exec. Conference Toilets and KitchenA620 Toilet & Shower LayoutsA621 Standard Toilet AccessoriesA622 Interior Elevations, Details, Door and Window Types

03 - StructuralS1.0 General Structural NotesS2.0 Structural Plans & Sections

04 - PlumbingP2.1B Partial Demolition & New Work Floor Plans

05 - MechanicalM0.01 Legends, Schedules, and DetailsM2.1B New Work and Demo Plans - Area B

06 - ElectricalE0-1 Legend and IndexE0-2 Existing Single LineE0-3 SchedulesE1-1 Electrical DemolitionE2-1 New Work LightingE3-1 New Work Power & Systems

Vicinity Map

Revision Schedule

Revision#

RevisionDescription

RevisionDate

Page 3: Columbus Metropolitan Library - Miscellaneous Renovations...CL / Center Line CLG Ceiling CLR Clear CMU Concrete Masonry Unit CO Clean Out COL Column COMP Composition/ Composite CONC

J

H

G

4321 2.6

E

F

ElevatorLobbyParking

Garage

Existingsprinkler valve

3501

A1A622 4

VAN

ACCESSIBLE

13

14

5' - 0"

16

19

17

A2

18

11' -

0" 21

J

H

G

F

65.554321

H6

2.61.3

Vestibule

Book ReturnWorkroom

Jan

Women

Men

Hall

F1 Elevator Lobby

Reserves

P4.5 Elevator Lobby

Auditorium

E

F

A3

4501

5001

16' - 0" 4' - 0"

12

3

4

5

6

7

8 12

1510

1811

A622

1

9

93-B

93-B

93-B

20

Alt. 3

H

G

F

65.554321

H6

2.6

Book ReturnWorkroom

Vestibule

Men

Women

Jan 9' - 0" A.F.F.

ACT

9' - 0" A.F.F.

ACT

1

33

2

4

4

4

4

4

4

J

H

4321 2.6

Elevator Lobby

54

4

4

FLOOR PLAN - CODED NOTES1. Alternate 3 - Saw cut new opening in garage concrete wall.

2. Alternate 3 - Remove CMU vestibule including door, frame, doorcontrols, ceiling system, and flooring. Patch new vestibule walls toremain.

3. Alternate 3 - Remove metal stud partition. Patch adjacent wallsto remain.

4. Alternate 3 - Remove door and frame. Infill opening to matchadjacent surfaces. Paint all walls.

5. Remove existing partition and salvage door and frame. Providenew partition and reinstall door and frame in new location. Paint newpartition, door, and frame.

6. Remove and salvage base cabinet and countertop toaccommodate new layout shown. Turn cabinets over to the owner.

7. Remove existing kitchenette flooring and replace with new sheetvinyl flooring in reduced size kitchenette.

8. Remove partition to enlarge elevator lobby. Patch walls toremain. Remove existing kitchenette floor and extend ceramic tile ofelevator lobby through new lobby area.

9. Paint elevator lobby walls.

10. Alternate 3 - CMU infill. Paint to match.

11. Alternate 3 - Demolish former entry ramp. Grind flush withgarage deck. Patch adjacent walls and floor slab.

12. New elevator E hoistway level P4.5 opening. Provide newelevator equipment and cab per specification section section 14 2713. Patch and repaint hoistway entrance wall.

13. Alternate 1 - Sawcut new elevator E hoistway openings at levelsP1.5, P2.5, and P3.5. Provide lobby vestibule indicated by 2/A101.Provide new elevator equipment per specification 14 27 13. Repainthoistway entrance wall.

14. Alternate 2 - Sawcut new elevator F hoistway openings at levelsP1.5, P2.5, and P3.5. Provide new elevator equipment perspecification 14 27 13. Repaint hoistway entrance wall.

15. Alternate 3 - New aluminum storefront system at floor level F1.

16. Alternate 1 - New aluminum storefront system at lower levelelevator lobbies.

17. Alternate 1 - sheet vinyl flooring.

18. Traffic paint striping.

19. Remove existing parking space striping and replace with newvan accessible parking space striping.

20. Alternate 3 - New cast in place concrete steps and ramp.

21. Sawcut 8'-0" wide by 8'-4" high oversized hoistway temporaryopening between Level P3.5 and Level P4.5 to allow for installation ofnew elevator cab. Infill hole completely once new cab is in place ifAlternate 1 not accepted. Infill portion of hole to reduce size to that ofstandard hoistway opening once new cab is in place if Alternate 1 isaccepted. Patch and repaint hoistway wall.

REFLECTED CEILING PLAN - CODED NOTES1. Provide new vestibule ceiling system.

2. Extend ceiling system into new lobby area.

3. Cut/break existing ceiling system.

4. Existing ceiling system.

5. Alternate 1 - Painted concrete deck (Level P1.5 and P2.5).

ELEVATOR GENERAL SCOPE NOTES:A. Base Bid work - Upgrade elevator E by replacing car, addingnew stop within existing travel range at auditorium level, andassociated work to enlarge elevator lobby at this landing location.Provide new control software to existing elevator control system.

B. Alternate 1 - Further upgrade elevator E to add new stops withinexisting travel range at parking garage levels P1.5, P2.5, P3.5; andprovide lobby vestibules at these new garage stops.

C. Alternate 2 - Upgrade elevator F by adding new stops withinexisting travel range at parking garage levels P1.5, P2.5, P3.5.

Consultants:

300 Marconi BoulevardColumbus OH 43215schooleycaldwell.com

614-628-0300614-628-0311

TF

Drawing Issue Dates

Bidding

8/24

/201

7 11

:28:

53 A

MC

:\Rev

itLoc

al\1

7220

_CM

L A

dditi

onal

Ser

vice

s_v2

016_

ldun

field

.rvt

ColumbusMetropolitanLibrary -MiscellaneousRenovations96 South Grant AvenueColumbus, OH 43215

08.08.2017

P1.5, P2.5, P3.5,P4.5 & F1 FloorPlans

A10117220

Architectural

Aug 15, 2017

3/32" = 1'-0"2 P1.5, P2.5 & P3.5 Typical Floor Plan

3/32" = 1'-0"1 Level P4.5 & F1 Floor Plan

3/32" = 1'-0"3 Level P4.5 & F1 Reflected Ceiling Plan

3/32" = 1'-0"4 P1.5, P2.5 & P3.5 Typical Reflected Ceiling Plan

Revision Schedule

Revision#

RevisionDescription

RevisionDate

Page 4: Columbus Metropolitan Library - Miscellaneous Renovations...CL / Center Line CLG Ceiling CLR Clear CMU Concrete Masonry Unit CO Clean Out COL Column COMP Composition/ Composite CONC

A102

5

TOILET ROOM2132

TOILET ROOM2131

KITCHEN 2128

STOR.

A10210 8

A102 4

3

9

7

6

14

A102

13

A102

trash grommet

2' -

4"

1' -

9"

1028 A1

12

A102

11

A102

1028 B2

flooring direction

12

A102sim.

6001

Card reader - channel andpatch wall to run electric

Remove existing doors andframe, patch walls andinstall new doors and frame

CARNEGIECONFERENCE

ROOM 2127

DEMOLITION - GENERAL NOTES -CARNEGIE CONFERENCE ROOMA. Kitchen 2128: Remove all existing cabinets, countertop, sink,and faucet; salvage existing garbage disposal and refrigerator forre-use in new work.

B. Toilet Rooms 2131 & 2132: Remove all existing fixtures,accessories and flooring; salvage all accessories and fixtures; turnover any un-used pieces to Owner.

NEW WORK - GENERAL NOTES -CARNEGIE CONFERENCE ROOMA. Kitchen 2128: Provide new wood veneered cabinets, solidsurface countertop, under-mounted sink, faucet, concealed papertowel dispenser, soap pump, hot-water dispenser, glass tilebacksplash, and rubber base; re-install existing garbage disposal andrefrigerator. Existing carpet to remain.

B. Toilet Room 2131: Provide new solid surface vanity top andpanels, under-mount sink, faucet, countertop mounted soapdispenser, concealed paper towel dispenser, toilet tissue dispenser,trash grommet, garbage can, mirror, and new ceramic tile flooring;re-install existing toilet and grab bars. Existing ceramic wall tile toremain

C. Toilet Room 2132: Provide new pedestal sink, garbage can,toilet paper dispenser, concealed paper towel dispenser, ceramic tilewet wall and ceramic tile flooring; Re-install existing toilet and soapdispenser.

D. Provide new light-sensors in Toilet Rooms 2131 & 2132.

E. Repaint all walls in Toilet Rooms 2131 & 2132; 0991 P2.

F. Repaint all walls in Kitchen 2128 to be painted 0991 P2 unlessotherwise noted.

KITCHEN 2128

TOILET ROOM2131

TOILET ROOM2132

RCP - GENERAL NOTES -CARNEGIE CONFERENCE ROOMA. Paint existing gypsum board soffit in Kitchen 2128; 0991 P1

Exg. Refrigerator

Wood VeneeredCabinets, typ.

Pull-out trash caninside cabinet

0930 SG

1236 S

0991 P10991 P1

1236 S

1' - 9"filler

12

A102

lower existing electricaloutlet to align withoutlet on adjacent wall

Wood veneered cabinets

2' - 0"

1028 A1

1028 D2

1236 Swith under-mount sink

0930 SG

0991 P1

filler1' - 6"

12

A102

sim.11

A102

2' -

10"

4' -

0"

4"

14

A102

6' - 0"

1028 C1

1028 A 2

1028 D2

0991 P2

0930 CB

1236 S1236 S

13

A102

3 equal removable panels, 1236 S

2650 L 2

Re-use existingtoilet in same location

Re-use existing grabbars in same location

1028 E

8"

2' -

3"

A102

14

0991 P2

0930 CB

Re-use existing grab barsin same location

Re-use existing toiletin same location

0930 Cexisting to remain

1028 E

Pedestal Sink

1028 Dexisting to remain

1028 Cexisting to remain

0991 P2

1028 A1

1028 B1

2650 L

3' -

4"

0930 CB

1

2' -

3"

8"

Re-use existing toiletin same location, typ.

New pedestal sink

1028 D

1028 E

existing to remain

0991 P2

3' -

4"

0930 CB

4"1

1/4"

4"2'

- 1

1 1/

4"

1/2" solid surface backsplash

1/2" solid surface on 3/4"marine grade plywood;1/2" solidsurface front edge -mitred

Blocking, typ.Dw

r F

ront

5 3/

4"

Drawer: 3/4" veneered plywood with4-sided drawer box: 1/2" solid wood sideswith fully captured bottom - 1/4" hardboard

Cabinet box: 3/4" MDF with Plam on allexposed sides and edges

Cabinet Door:3/4" veneered plywood;stain to match architectssample

Cabinet Face: solid3/4" wood; stain to matcharchitects sample

3"

3/4" Marine grade plywoodwith 0965 B

2' - 1"

Hafele #502.74.813 trash can glide -Hailo US Cargo 18

1' - 10"

2' -

10"

1/2" solid surface with mitred front edge, typ.

3/4" Marine grade plywood

Blocking, typ.

Under-mount sink

6 1/

4"

4"

Removable 1/2"solid surfacepanel on "z-clips", provide 3equal sections

8"

10"

9"

1' - 6 3/4"

0930 CB

3"

0930 CF

Intermediate support wherepanels meet; 0991 P2

paint framing for solidsurface panel; 0991 P2

CABINET HARDWARE SCHEDULEPulls: Hafele #117.05.630 - Matt Stainless Steel Pull

Hinge: Salice Concealed Hinge 200 Series; nickel-plated; soft-close; provide matching mounting plate

Drawer Glide: Salice Full Extension #A7555 Futura 16(75lbs/pair, cushioned stop); provide clips and mounting bracketsas needed.

Trash Can Glide: Hafele #502.74.813 - US Cargo 18

Trash Grommet: Mockett TM1C, 6" DIA. x 3" deep, stainless steel

1028 E

0930 C

1' - 10"

1/2" solid surface with mitred front edge, typ.

3/4" Marine grade plywood

Blocking, typ.

6 1/

4"

4"

8"

Removable 1/2"solid surfacepanel on "z-clips",provide 3 equalsections

1028 A2

3"6"

10"

1' - 6 3/4"

9"

0930 CB

3"

0930 CF

Intermediate support where panels meet; 0991 P2

Paint framing for solidsurface panel; 0991 P2 4"

1 1/

4"

4"2'

- 1

1 1/

4"

1/2" solid surface backsplash

1/2" solid surface on 3/4"marine grade plywood; 1/2"solid surface front edge - mitred

Blocking, typ.

Dw

r F

ront

5 3/

4"

Drawer: 3/4" veneeredplywood with 4-sided drawerbox: 1/2" solid wood sideswith fully captured bottom -1/4" hardboard, typ.

Cabinet box: 3/4" MDF

Cabinet Face: solid3/4" wood; stain to matcharchitects sample

3"

3/4" Marine grade plywoodwith 0965 B

2' - 1"

Dw

r fr

ont

5 1/

2"

Dw

r fr

ont

5 1/

2"

Dw

r fr

ont

1' -

0 1

/8"

Consultants:

300 Marconi BoulevardColumbus OH 43215schooleycaldwell.com

614-628-0300614-628-0311

TF

Drawing Issue Dates

Bidding

8/24

/201

7 11

:29:

08 A

MC

:\Rev

itLoc

al\1

7220

_CM

L A

dditi

onal

Ser

vice

s_v2

016_

ldun

field

.rvt

ColumbusMetropolitanLibrary -MiscellaneousRenovations96 South Grant AvenueColumbus, OH 43215

08.08.2017

2nd Floor Carnegie -Exec. ConferenceToilets and Kitchen

A10217220

Architectural

Aug 15, 2017

1/4" = 1'-0"1 Carnegie Kitchen and Restroom Enlarged Plan

1/4" = 1'-0"2 Carnegie Kitchen and Restroom RCP

1/4" = 1'-0"4 South Elevation - Kitchen

1/4" = 1'-0"3 West Elevation - Kitchen

1/4" = 1'-0"8 South Elevation - Toilet 2131

1/4" = 1'-0"9 East Elevation - Toilet Room 2131

1/4" = 1'-0"10 North Elevation - Toilet Room 2131

1/4" = 1'-0"5 West Elevation - Toilet Room 2132

1/4" = 1'-0"7 North Elevation - Toilet Room 2132

1 1/2" = 1'-0"12 Typical Base Cabinet Detail

1 1/2" = 1'-0"14 Vanity Sink Detail

1/4" = 1'-0"6 East Elevation - Toilet Room 2132

1 1/2" = 1'-0"13 Vanity Detail at paper towel dispenser condition at trash grommet sim.

1 1/2" = 1'-0"11 Base Cabinet Detail

Revision Schedule

Revision#

RevisionDescription

RevisionDate

Page 5: Columbus Metropolitan Library - Miscellaneous Renovations...CL / Center Line CLG Ceiling CLR Clear CMU Concrete Masonry Unit CO Clean Out COL Column COMP Composition/ Composite CONC

WC-2

ACCESSIBLE TOILETCOMPARTMENT PLAN

5' -

6"

17"

40"

8"

5' - 1"

OPENING

34" MIN CLEAR

42"

(MIN

IMU

M)

ACCESSIBLE TOILET COMPARTMENT -END OF ROW

WC-2

1028 G2

42"

(MIN

IMU

M)

OP

EN

ING

34"

MIN

CLE

AR

4"

9' -

0"

(MIN

IMU

M)

RE

FE

R T

O P

LAN

9' -

0"

(MIN

IMU

M)

RE

FE

R T

O P

LAN

AMBULATORY ACCESSIBLETOILET COMPARTMENT

OPENING

34" MIN CLEAR

42"

(MIN

IMU

M)

5' -

6"

3' - 0"

18"

STANDARD TOILETCOMPARTMENT PLAN

OPENING

30" MIN. CLEAR

WC-1

17"

5' - 1"

1028 G7

1028 G2

1028 G7

12"

8"

40"

1028 G41028 G4

1028 G61028 G6

1028 E

1028 E1028 E

5' -

6"

3' - 0"

WC-2

9' -

0"

(MIN

IMU

M)

RE

FE

R T

O P

LAN

8"

40"

8"

1028 E

42"

(MIN

IMU

M)

9' -

0"

(MIN

IMU

M)

RE

FE

R T

O P

LAN

1021 T

1021 T

1021 T

1021 T

STANDARD URINALPLAN

UR-1

ACCESSIBLE URINALPLAN

UR-2

18" 18"

18" 18"

22"

22"

1021 T

1021 T

STANDARD TOILET STALLS AND ACCESSIBLE TOILET ROOMS

SINGLE OCCUPANT ACCESSIBLETOILET ROOM PLAN

WC-2

6' -

8"

(MIN

IMU

M)

RE

FE

R T

O P

LAN

17"

8"

40"

19"

7' - 6" (MINIMUM) REFER TO PLAN

32" MIN. CLEAR

1028 G6

1028 E

1028 G8

1028 C

1028 D

1028 A1028 B

1028 F 1028 K

1028 K

1028 K1028 K

1028 K

1028 O*

* AT FEMALE ONLY

1028 O

1028 O

1028 O

*

*

*

SINGLE OCCUPANT ACCESSIBLETOILET ROOM PLAN

WC-2

17"

8"

40"

19"

7' - 6" (MINIMUM) REFER TO PLAN

32"

MIN

. CLE

AR

1028 G6

1028 E

1028 G81028 C

1028 D1028 A1028 B

1028 F

1028 K

6' -

2"

(M

INIM

UM

) R

EF

ER

TO

PLA

N

12"

17"

8"

40"

19"

7' - 6" (MINIMUM) REFER TO PLAN

1028 G6

1028 E

1028 G71028 C

1028 D

1028 A1028 B

1028 F

1028 K

6' -

8"

(M

INIM

UM

) R

EF

ER

TO

PLA

N

18"

32"

MIN

. CLE

AR

SINGLE OCCUPANT ACCESSIBLETOILET ROOM PLAN

WC-2

SINGLE OCCUPANT ACCESSIBLETOILET ROOM PLAN

5' -

0"

(MIN

IMU

M)

RE

FE

R T

O P

LAN

17"

40"

10 1/8"

8' - 0" (MINIMUM) REFER TO PLAN

1028 C

1028 D

1028 A1028 B

1028 F1028 K

WC

-2

1028 G6

1028 E

1028 G8

S1 S2 S3 S4

U1

U2

T1 T2 T3 T4

56" min. clear60" m

in. clear

58"

6"

37"

40"

48"

35"

22"

6"32

"

17"

12"

24"

12"

30"

20"

17"

Notes:• The clear floor area is permitted to overlap the water closet, associated

grab bars, paper dispensers, sanitary napkin receptacles, coat hooks,shelves, clear floor space at other fixtures and the turning space.

• No other fixture shall be within the required water closet clearance.• Flush controls shall be located on the open side of the water closet.• Hatched zone at walls indicates minimum extent of continuous in-wall

reinforcement.• Combination L-shaped grab bars (Item 1028G8) may be utilized in lieu of

items 1028G4 and 1028G5.

1028 G4

1028 G5

1028 G6

1028 E

ACCESSIBLE TOILET STALLS & ROOMS

Consultants:

300 Marconi BoulevardColumbus OH 43215schooleycaldwell.com

614-628-0300614-628-0311

TF

Drawing Issue Dates

Bidding

8/24

/201

7 11

:29:

18 A

MC

:\Rev

itLoc

al\1

7220

_CM

L A

dditi

onal

Ser

vice

s_v2

016_

ldun

field

.rvt

ColumbusMetropolitanLibrary -MiscellaneousRenovations96 South Grant AvenueColumbus, OH 43215

08.08.2017

Toilet & ShowerLayouts

A62017220

Architectural

Aug 15, 2017

Revision Schedule

Revision#

RevisionDescription

RevisionDate

Page 6: Columbus Metropolitan Library - Miscellaneous Renovations...CL / Center Line CLG Ceiling CLR Clear CMU Concrete Masonry Unit CO Clean Out COL Column COMP Composition/ Composite CONC

2' -

10"

to

rim

1028 C

1028 U

UNDERMOUNTLAVATORY

39"

40"

to S

pout

CL

34"

KEYNOTE 1028 A

FINISH FLOOR

40"

TOILETACCESSORY TYPE

Paper TowelDispenser

MOUNTING TYPE

1028 A

Waste Receptacle

Recessed Freestanding

1028 B 1028 C 1028 C

Mirror(over counter)

1028 D

Soap Dispenser

1028 E

Toilet TissueDispenser - Vertical

Recessed

8"

27"

1028 G1

Horizontal Grab Bars

See Keynote

Varies

40"

40"

1028 G3

1028 G2

1028 G4

Surface mounted /partition mounted

match vanity width

42"

Center on Lav(where occurs)

1028 G6

Vertical Grab Bar 42" x 54" L-shaped Grab Bar16" x 31" L-shaped Grab Bar

Surface mounted /partition mounted

Surface mounted /partition mounted

1028 G7 1028 G8

TOILET ACCESSORY MOUNTING DIAGRAM

FIXTURE AND PARTITION MOUNTING DIAGRAM

1028 G5

2'-1

0" to

CL

MODEL Bobrick B-318

Recessed incountertop

Surface mounted Surface mounted Surface mounted

Bobrick channelframe mirror

existing to remain

2'-1

0" to

CL

existing to remain existing to remain

FLOOR MOUNTEDTOILET

17 5/8"

26 7/8"

Bobrick B-526 Bobrick B-3888

Paper TowelDispenser

Simplehuman 2.6gallon semi-round,stainless steel

Mirror(over pedestal sink)

Surface mounted

existing to remain

39"

42"

1 21 2 1028 E

Soap Dispenser

Countertop mounted

Bobrick B-82216

1 D 21 1028 B 2

Waste Receptacle

Freestanding

Uline H5148, gray existing to remain existing to remain

Consultants:

300 Marconi BoulevardColumbus OH 43215schooleycaldwell.com

614-628-0300614-628-0311

TF

Drawing Issue Dates

Bidding

8/24

/201

7 11

:29:

29 A

MC

:\Rev

itLoc

al\1

7220

_CM

L A

dditi

onal

Ser

vice

s_v2

016_

ldun

field

.rvt

ColumbusMetropolitanLibrary -MiscellaneousRenovations96 South Grant AvenueColumbus, OH 43215

08.08.2017

Standard ToiletAccessories

A62117220

Architectural

Aug 15, 2017

Revision Schedule

Revision#

RevisionDescription

RevisionDate

Page 7: Columbus Metropolitan Library - Miscellaneous Renovations...CL / Center Line CLG Ceiling CLR Clear CMU Concrete Masonry Unit CO Clean Out COL Column COMP Composition/ Composite CONC

EQ 2" 3' - 0" 2" EQ 2" EQ 2" EQ 2" EQ 2"

7' -

1"

EQ 2"

23' - 10 1/2"

4"

9

A622

A1.2 Levels P3.5

0841 S Alternate #1

7' -

1"

13' - 8"

2" EQ2" EQ2" EQ2" EQ

4" A2.2 Levels P3.5

9

A622

Alternate #1

16' - 0"

A3

7' -

4"

1-Hour Rated Assembly4"4"

2 1/2" EQ2 1/2"

3' - 0"2 1/2"

EQ2 1/2"

EQ2 1/2"

EQ 2 1/2"

8

A622

Alternate #3

F

See

Sch

edul

e

See Sched.

FG2RATED

See

Sch

edul

e

See Sched.See Sched.

See

Sch

edul

e

FG1

2" See Sched. 2"

2"S

ee S

ched

ule

1

Alternate 1:Add (3) additionalstops for elevator "E"at P3.5, P2.5, andP1.5

Alternate 2:Add (3) additionalstops for elevator "F"at P3.5, P2.5, andP1.5

Aluminum storefront

Storefront systemexpansion track

Existing ceilingassembly2"4"

60 minute ratedstorefront assembly

Existing concrete wall

Sealant each side

G

5.55

5' -

0" 5'

- 0

"

2

A622

3

A622

1 / 12

99' - 1"

99' - 6 1/2"

100' - 0"

4' - 2"

11' - 0" 5' - 0" Clear

LEVEL 1LEVEL P5

LEVEL 1

LEVEL P5

1' - 0" Min. 11" 11" 1' - 0" Min.

Max

.

2' -

2"

3' -

0" Painted steel pipe railing

LEVEL 1

LEVEL P5

3 1/

2" M

ax.

3' -

0"

1' - 0" Min. 1' - 0" Min.EQEQEQ

Max

.

2' -

2"

Painted steel pipe railing

A622

5

Aluminum storefront

Storefront systemexpansion track

Existing ceilingassembly

10"

2"4"

2"

Infill panel

0929 G0929 G

0922 F

J-bead each side

Sealant each side

A1.1 Levels P1.5 & P2.5

7' -

8"

4"6'

- 8

"

EQ 2" EQ 2" 3' - 0" 2" EQ 2" EQ 2" EQ 2" EQ 2"

23' - 10 1/2"

FLOOR LEVEL

Metal infillpanel

0841 S

6

A622

Alternate #1

7

A622

A2.1 Levels P1.5 & P2.5

Metal infillpanel

Infill area between storefront headand underside of deck with newpartition type 93-B

7' -

8"

10"

13' - 8"

2" EQ 2" EQ 2" EQ 2" EQ

4"6'

- 8

"

Alternate #1

Size: Steel Construction Wood Construction0 7/8" Furring Channel -1 1 1/2" Furring Channel 3/4" Furring2 2 1/2" C-Stud 4x2 Stud3 3 5/8' C-Stud -4 4" C-Stud 2x4 Stud5 5 1/2" C-Stud -6 6" C-Stud 2x6 Stud8 8" C-Stud 2x8 StudS2 2 1/2" CH-Shaftwall -S4 4" CH-Shaftwall -V varies C-Stud 2x4 Stud

Construction Type:(CSI Spec Division)

5 Cold Formed Metal Framing6 Wood Framing9 Non-Structural Metal Framing

Key for Wood & Metal Stud Partitions Sheathing Designation

90-X-X

Sheathing Designation:

Partition General Notes

1. All new interior partitions shall utilize abuse reistantgypsum wall board on each side of wall construction.

2. All new interior partitions shall have acoustical sealant at allperimeter joints and penetration joints for both sides of wall.

3. Extend all walls to the underside of the structure unlessnoted otherwise.

# of Material Material(s) Layers Thickness

A 1 5/8" Gypsum board on one side, no finish on other side

B 1 5/8" Gypsum board on each side

C 2 5/8" Gypsum board on each side

D 1 5/8" Gypsum board on one side1 5/8" Gypsum board on 1/2" resilient channels other side

E 2 5/8" Gypsum board on one side2 5/8" Gypsum board on 1/2" resilient channels other side

F 1 5/8" Gypsum board on one side1 1" Gypsum shaftliner in CH stud

G 2 5/8" Gypsum board on one side1 1" Gypsum shaftliner in CH stud

Head Condition:Stud Height Finish Height

1 Underside of Ceiling Underside of Ceiling2 6" Above Ceiling 6" Above Ceiling3 Structure Above Underside of Ceiling4 Structure Above 6" Above Ceiling

**if no condition is noted, stud and finish extend tostructure above

250S125-30 (92-B)362S125-30 (93-B)600S125-30 (96-B)

Unless Otherwise Noted

16" O.C.

4 7/

8 "

93-B

0922 F0922 F

0929 G

0929 G

NOTES:• Fire resistive rating of up to 1-hour as indicated on the plans• Construct rated assemblies in accordance with ANSI/UL 263 design:BXUV.U419• 92-B: limiting unbraced partition height 11-7" (10'-2" AT 24" C/C)• 93-B: limiting unbraced partition height 13'-6" (11'-8" at 24" C/C)• 96-B: limiting unbraced partition height 20'-0" (16'-8" at 24" C/C)• Non-loadbearing partition

PARTITION TYPES: 92-B, 93-B & 96-B09/A622

7 1/

4 "

96-B

3 3/

4 "

92-B

Aluminum storefront

Storefront systemexpansion track

Existing ceilingassembly2"

4"2"

Infill panelLEVEL P54"

Aluminum threshold ramp

Existing floor slab

New cast in place concrete ramp

Consultants:

300 Marconi BoulevardColumbus OH 43215schooleycaldwell.com

614-628-0300614-628-0311

TF

Drawing Issue Dates

Bidding

8/24

/201

7 11

:30:

00 A

MC

:\Rev

itLoc

al\1

7220

_CM

L A

dditi

onal

Ser

vice

s_v2

016_

ldun

field

.rvt

ColumbusMetropolitanLibrary -MiscellaneousRenovations96 South Grant AvenueColumbus, OH 43215

08.08.2017

Interior Elevations,Details, Door andWindow Types

A62217220

Aug 15, 2017

1/4" = 1'-0"Storefront Types

1/4" = 1'-0"Door Types

Door & Frame Schedule

DOORMARK

DOOR FRAME

FIRERATING

HARDWARE

REMARKSTYPESIZE

TYPE SET NO ELECTRICALW HLEVEL P1.5

1501 FG1 3' - 0" 7' - 0" A1 - 2 X Alternate #1LEVEL P2.5

2501 FG1 3' - 0" 7' - 0" A1 - 2 X Alternate #1LEVEL P3.5

3501 FG1 3' - 0" 6' - 11" A1 - 2 X Alternate #1LEVEL P4.5

4501 F 3' - 0" 7' - 0" - - - - Door & frame relocated from previous locationLEVEL 1

5001 FG2 3' - 0" 7' - 0" A3 1-HR 3 X Alternate #3LEVEL 2

6001 FG1 6' - 0" 7' - 6" 1 - 1 X (2) Leafs

1/4" = 1'-0"Frame Types

1/4" = 1'-0"4 P1.5, P2.5 & P3.5 Typical Elevator Lobby Elevation

1 1/2" = 1'-0"9 A1.2 & A2.2 Head Detail

1 1/2" = 1'-0"8 A3 Head Detail

1/4" = 1'-0"1 Enlarged Ramp Plan

1/4" = 1'-0"2 Ramp Section

1/4" = 1'-0"3 Stair Section

1 1/2" = 1'-0"7 A2.1 Head Detail

1/4" = 1'-0"Storefront Types

1 1/2" = 1'-0"6 A1.1 & A2.1 Head Detail

3/4" = 1'-0"5 A622 - Ramp Detail

General Storefront System Fastening Note:Existing garage concrete deck and structure ispost-tension concrete. Maximum fastener depthinto existing concrete shall be 1".

Revision Schedule

Revision#

RevisionDescription

RevisionDate

Page 8: Columbus Metropolitan Library - Miscellaneous Renovations...CL / Center Line CLG Ceiling CLR Clear CMU Concrete Masonry Unit CO Clean Out COL Column COMP Composition/ Composite CONC

01000 - GENERAL STRUCTURAL NOTES

1. THE GENERAL STRUCTURAL NOTES ARE INTENDED TO AUGMENT THE DRAWINGS AND SPECIFICATIONS.SHOULD CONFLICTS EXIST BETWEEN THE DRAWINGS AND SPECIFICATIONS AND THE GENERAL STRUCTURALNOTES, THE STRICTEST PROVISION SHALL GOVERN.

2. GOVERNING CODE: OHIO BUILDING CODE - 2011 EDITION.3. SEE STRUCTURAL PLANS FOR DESIGN SOIL BEARING PRESSURE AND LIVE LOADS. LIVE LOADS

REDUCED IN ACCORDANCE WITH THE GOVERNING CODE.4. ROOF SNOW LOAD:

GROUND SNOW LOAD (Pg) - 20 PSFSNOW EXPOSURE FACTOR (Ce) - 1.0IMPORTANCE FACTOR (Is) - 1.0THERMAL FACTOR (Ct) - 1.0FLAT ROOF SNOW LOAD (Pf) - 20 PSF

5. WIND LOAD:BASIC WIND SPEED - 90 MPHIMPORTANCE FACTOR (Iw) - 1.15EXPOSURE CATEGORY - EXPOSURE BINTERNAL PRESSURE COEFFICIENT(G Cpi) - ±0.18

6. SEISMIC LOAD: EXISTING BUILDING7. MECHANICAL FRAMING LOADS, OPENINGS, AND STRUCTURE IN ANY WAY RELATED TO MECHANICAL REQUIREMENTS

ARE SHOWN FOR BIDDING PURPOSES ONLY. CONTRACTOR SHALL OBTAIN APPROVAL OF MECHANICAL AND OTHERTRADES BEFORE PROCEEDING WITH SUCH PORTION OF THE WORK. EXCESS COST RELATED TO VARIATION INMECHANICAL REQUIREMENTS TO BE BORNE BY MECHANICAL CONTRACTOR. COORDINATE SIZE AND LOCATION OFALL OPENINGS WITH THE MECHANICAL DRAWINGS.

8. THE STRUCTURE IS DESIGNED TO BE SELF-SUPPORTING AND STABLE AFTER THE BUILDING IS FULLY COMPLETED. ITIS SOLELY THE CONTRACTOR'S RESPONSIBILITY TO DETERMINE DEMOLITION PROCEDURES, ERECTION PROCEDURESAND SEQUENCES AND TO ENSURE THE SAFETY OF THE BUILDING AND ITS COMPONENT PARTS DURING ERECTION.THIS INCLUDES THE ADDITION OF WHATEVER TEMPORARY BRACING, GUYS, OR TIE-DOWNS WHICH MIGHT BE NECESSARY.SUCH MATERIAL SHALL REMAIN THE CONTRACTOR'S PROPERTY AFTER COMPLETION OF THE PROJECT.

9. IT IS SOLELY THE CONTRACTOR'S RESPONSIBILITY TO FOLLOW ALL APPLICABLE SAFETY CODES AND REGULATIONS DURINGALL PHASES OF CONSTRUCTION.

10. THE CONTRACTOR IS RESPONSIBLE FOR VERIFYING ALL DIMENSIONS AND CONDITIONS RELATING TO EXISTING CONSTRUCTIONAND EXISTING SERVICE ON THE SITE.

11. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND LOCATIONS OF COLUMNS, WALLS, OPENINGS ETC. WITH THEARCHITECTURAL DRAWINGS PRIOR TO PROCEEDING WITH THE WORK.

033000 - REINFORCED CONCRETE

1. SPECIFICATIONS AND STANDARDS:CONCRETE WORK, DETAILING, FABRICATION AND PLACING OF BARS AND CONCRETE SHALL BE GOVERNED BY THEAPPLICABLE VERSION OF:A. ACI 301, ACI 315, AND ACI 318.B. CRSI RECOMMENDED PRACTICE FOR PLACING REINFORCING BARS.C. ACI 306 AND ACI 305 FOR WINTER AND HOT WEATHER CONCRETING, RESPECTIVELY.THE CONTRACTOR SHALL AT ALL TIMES HAVE A COPY OF THE RELEVANT SPECIFICATIONS QUOTED ABOVE ON THE SITEAND THE SUPERVISORY PERSONNEL SHALL BE THOROUGHLY FAMILIAR WITH THE CONTENTS THEREOF.

2. CONTINGENCIES:A. LEAN CONCRETE UNDER FOUNDATIONS FOR EARTH FILL DUE TO ACCIDENTAL OVEREXCAVATION OR SOFT SPOTS.

3. CONCRETE REQUIREMENTS AND LOCATION IN JOB:SPECIAL

CLASS LOCATION f'c REQUIREMENTS 6 MASONRY GROUT 3000 PSI 7" SLUMP

3/8" MAX. AGG.

SUBMIT CONCRETE MIXES FOR APPROVAL IN ACCORDANCE WITH ACI 301 BEFORE PLACING ANY CONCRETE.4. REINFORCING REQUIREMENTS:

A. BARS: ASTM A615 - GRADE 60.B. WELDED WIRE REINFORCING: ASTM A185.C. SMOOTH BARS: ASTM A36.

5. OPENINGS:A. OPENINGS SHOWN ARE FOR BIDDING PURPOSES ONLY. CONTRACTOR SHALL COORDINATE SIZES AND LOCATIONS WITH

MECHANICAL AND OTHER REQUIREMENTS BEFORE PROCEEDING WITH THE WORK.B. IF ANY OPENING NOT SHOWN ON THE PLAN IS REQUIRED, APPROVAL MUST BE SECURED FROM THE STRUCTURAL

ENGINEER BEFORE PROCEEDING WITH THE WORK.

042000 - CONCRETE UNIT MASONRY

1. COMPRESSIVE STRENGTH OF MASONRY (f’m) 1500 PSI, DETERMINED BY UNIT STRENGTH OR PRISM METHOD.2. MASONRY MATERIALS:

A. HOLLOW AND SOLID LOAD BEARING CONCRETE MASONRY UNITS - ASTM C90 - NORMAL WEIGHT.B. CONCRETE BRICK - ASTM C55 GRADE N1.

3. MORTAR:A. CONCRETE UNIT MASONRY WALLS - ASTM C270 TYPE S.

4. COARSE MASONRY GROUT: SEE REINFORCED CONCRETE GENERAL NOTES.5. MASONRY REINFORCEMENT:

A. HORIZONTAL JOINT REINFORCEMENT: 9 GA DEFORMED WIRE, LADDER TYPE REINFORCEMENT.1. IN EVERY SECOND BLOCK COURSE, FULL HEIGHT, AND WHERE SHOWN ON DRAWINGS.2. IN FIRST BED JOINT ABOVE AND BELOW OPENINGS EXTENDING 24" BEYOND OPENING.3. LAP REINFORCEMENT A FULL WIDTH AT CORNERS AND INTERSECTIONS.

6. BEARING POINTS:A. BEAMS: 3 COURSES x 24" WIDE SOLID OR GROUTED SOLID MASONRY.B. JOISTS & LINTELS: 2 COURSES x 16" WIDE SOLID OR GROUTED SOLID MASONRY.

7. REINFORCED MASONRY:A. INSTALL REINFORCING BARS IN LOCATIONS SHOWN. LAP SPLICE REINFORCING 48 BAR DIAMETERS UNLESS NOTED.B. GROUT BLOCK WITH COARSE MASONRY GROUT VIBRATED IN PLACE TO FILL ALL VOIDS AND INTERSTICES. FOLLOW

RECOMMENDATIONS OF NCMA TEK NO. 3-2.8. POST-INSTALLED SLEEVE ANCHORS:

ONE PIECE WRAP AROUND EXPANSION SLEEVE. THE ENTIRE ANCHOR SHALL BE CARBON STEEL MEETING THEFOLLOWING REQUIREMENTS.

ANCHOR SIZE MINIMUM EMBEDMENT PULLOUT (LBS) SHEAR (LBS)1/4" DIAMETER 1" 250 2353/8" DIAMETER 1 1/4" 400 6501/2" DIAMETER 2 1/4" 800 9505/8" DIAMETER 3" 950 12503/4" DIAMETER 3 1/2" 1250 1900

LOADS INDICATED ABOVE ARE SERVICE LOADS IN POUNDS FOR SLEEVE ANCHORS IN CONCRETE MASONRY CONSTRUCTION.ANCHORS TO BE INSTALLED IN FULLY GROUTED CELLS.

9. POST-INSTALLED ADHESIVE ANCHORS:EMBED IN EPOXY RESIN ADHESIVE. THE ENTIRE ANCHOR SHALL BE ASTM A36 CARBON STEELMEETING THE FOLLOWING REQUIREMENTS:

ANCHOR SIZE MINIMUM EMBEDMENT PULLOUT(LBS.) SHEAR(LBS)3/8" DIAMETER 3 1/2" 1550 10501/2" DIAMETER 4 1/4" 1750 19005/8" DIAMETER 5" 2250 20003/4" DIAMETER 7" 3700 2000

LOADS INDICATED ABOVE ARE SERVICE LOADS FOR STEEL ANCHORS IN CONCRETE MASONRY CONSTRUCTION.ANCHORS TO BE INSTALLED IN FULLY GROUTED CELLS.

STRUCTURAL

SMBHENGINEERING

1166 Dublin Road Suite 200Columbus, OH 43215-1038614-481-9800www.smbhinc.com

Consultants:

300 Marconi BoulevardColumbus OH 43215schooleycaldwell.com

614-628-0300614-628-0311

TF

Drawing Issue Dates

BIDDING

smbh job no: 017-186

8/2

4/2

017 1

:57:4

3 P

M

C:\

Users

\tjk

\Docum

ents

\017-1

86-R

16_C

EN

TR

AL_T

JK

.rvt

96 South Grant AvenueColumbus, OH 43215

Renovation &Addition to theMain Library

06.19.2017

GENERALSTRUCTURALNOTES

S1.0

17220

AUG 15, 2017

Revision Schedule

Revision#

RevisionDescription

RevisionDate

Page 9: Columbus Metropolitan Library - Miscellaneous Renovations...CL / Center Line CLG Ceiling CLR Clear CMU Concrete Masonry Unit CO Clean Out COL Column COMP Composition/ Composite CONC

1 2 3 42.6

G

H

J

H6

ALTERNATE 1:-ADD (3) ADDITIONALSTOPS FOR ELEVATOR "E"AT P3.5, P2.5, AND P1.5-ADD (3) GARAGE VESTIBULESAT P3.5, P2.5, AND P1.5

ALTERNATE 2:-ADD (3) ADDITIONALSTOPS FOR ELEVATOR "F"AT P3.5, P2.5, AND P1.5

ELEV

-E

ELEV

-F

EXTG

CONCRE

TEBE

AM

EXTG

CONCRE

TEBE

AM

EXTG

CONCRE

TEBE

AM

1

S2.0

3

S2.0

TEMPORARY LARGE

OPENING BETWEEN

LEVEL 3.5 & 4.5

1 2 3 42.6

G

H

J

H6

5

BASE BID:-ADD STOP @ 4.5PFOR ELEVATOR "E"

ELEV

-EELEV

-F

EXTG

CONCRE

TEBE

AM

EXTG

CONCRE

TEBE

AM

EXTG

CONCRE

TEBE

AM

EXTG

CONCRE

TEBE

AM1

S2.0

2

S2.0

ALTERNATE 3:CMU WALL INFILL ATTHE EXTG OPENINGS

16'-0" 4'-0"

ALTERNATE 3:-INFILL EXTG OPENING-ADD NEW OPENING

T/NEW OPNGCOORD w/

ELEV MANUF

CORE DRILL CORNERSOF OPENING PRIOR TOSAW CUTTING. DONOT OVERSAW ATCORNERS

PT TENDON

PT TENDON

T/EXTG SLAB

ELEVATOR OPENING

PT TENDON

EXTG POST-TENSION SLAB

EXTG CONCBEAM BEYOND

EXTG CONC WALL

SEE DETAIL 1/S2.0FOR SAW CUTTINGPROCEDURE

T/NEW OPNGSEE ARCH

1. EXISTING SLABS AND RAMPS ARE 8" THICK POST-TENSION CONCRETE SLAB.2. INFORMATION FOR THE EXISTING BUILDING HAS BEEN TAKEN FROM DRAWINGS AND HAS NOT BEEN VERIFIED IN THE FIELD. CONTRACTOR SHALL VERIFY ALL RELEVANT CONDITIONS AND DIMENSIONS OF EXISTING CONSTRUCTION BEFORE PROCEEDING WITH THE WORK.3. THE EXISTING CONCRETE COVER FOR POST-TENSION TENDON AND SLAB REINFORCING ARE 1 1/2". THE MAXIMUM DEPTH FOR VESTIBULE FASTENERS SHALL BE 1".

T/NEW OPNGCOORD w/

ELEV MANUF

PT TENDON

PT TENDON

T/EXTG SLAB

ELEVATOR OPENING

VERIFY W/ELEV MANUF

3'-4"

VER

IFY W

/ EL

EV M

ANUF

7'-0

"

BRG

8"

BRG

8"

8'-0"

L4x3 1/2x1/4 LLVLINTEL FOR EACH4" THICKNESS OF CMUINFILL WALL

8'-4

"

8'-4" HIGHx8'-0"WIDETEMPORARY OPENINGW/ CMU INFILLBETWEEN LEVEL 3.5AND LEVEL 4.5

STRUCTURAL

SMBHENGINEERING

1166 Dublin Road Suite 200Columbus, OH 43215-1038614-481-9800www.smbhinc.com

Consultants:

300 Marconi BoulevardColumbus OH 43215schooleycaldwell.com

614-628-0300614-628-0311

TF

Drawing Issue Dates

BIDDING

smbh job no: 017-186

8/2

4/2

017 1

:57:4

3 P

M

C:\

Users

\tjk

\Docum

ents

\017-1

86-R

16_C

EN

TR

AL_T

JK

.rvt

96 South Grant AvenueColumbus, OH 43215

Renovation &Addition to theMain Library

06.19.2017

STRUCTURALPLANS &SECTIONS

S2.0

17220

AUG 15, 2017

1/8" = 1'-0"

P1.5,P2.5, & P3.5 FLOOR PLAN 1/8" = 1'-0"

LEVEL P4.5 & F1 FLOOR PLAN

3/4" = 1'-0"S2.0

1 DETAIL 3/4" = 1'-0"S2.0

2 DETAIL

1. EXISTING SLABS AND RAMPS ARE 8" THICK POST-TENSION CONCRETE SLAB.2. INFORMATION FOR THE EXISTING BUILDING HAS BEEN TAKEN FROM DRAWINGS AND HAS NOT BEEN VERIFIED IN THE FIELD. CONTRACTOR SHALL VERIFY ALL RELEVANT CONDITIONS AND DIMENSIONS OF EXISTING CONSTRUCTION BEFORE PROCEEDING WITH THE WORK.3. THE EXISTING CONCRETE COVER FOR POST-TENSION TENDON AND SLAB REINFORCING ARE 1 1/2". THE MAXIMUM DEPTH FOR VESTIBULE FASTENERS SHALL BE 1".

3/4" = 1'-0"S2.0

3 DETAIL

Revision Schedule

Revision#

RevisionDescription

RevisionDate

Page 10: Columbus Metropolitan Library - Miscellaneous Renovations...CL / Center Line CLG Ceiling CLR Clear CMU Concrete Masonry Unit CO Clean Out COL Column COMP Composition/ Composite CONC

1. PIPE REDUCER IF COIL CONNECTION SIZE DIFFERS FROM PIPESIZE.

2. INSULATE PIPING UP TO SHUT-OFF VALVE.

3. MAXIMUM DISTANCE FROM SHUT-OFF VALVE TO COIL IS 48".

4. SEASONAL AUTO SHUT-OFF VALVE, LINE SIZE.

A. ALL PIPING SHALL BE FULL SIZE OF MAIN RUN-OUT PIPINGUNLESS NOTED OTHERWISE.

B. REFER TO EQUIPMENT SCHEDULE FOR AUTOMATICCONTROL VALVE SIZE.

M

1 COIL

2

23

48" MAX

NOTES

GENERAL NOTES

4

NOTE: ALL SYMBOLS AND ABBREVIATIONS ARE SUBJECT TO MODIFICATIONS ON OTHER DRAWINGS.

ALL SYMBOLS OR ABBREVIATIONS MIGHT NOT NECESSARILY BE USED ON THIS PROJECT.

ABBREVIATIONS

AC - AIR COMPRESSOR OR AIR CONDITIONERACCU - AIR COOLED CONDENSING UNITAD - ACCESS DOOR OR AREA DRAINADJ - ADJUSTABLEAFF - ABOVE FINISHED FLOORAFG - ABOVE FINISHED GRADEALT - ALTERNATEAP - ACCESS PANELAPPROX - APPROXIMATEARCH - ARCHITECT OR ARCHITECTURALASSY - ASSEMBLY

BDD - BACK DRAFT DAMPERBFP - BACKFLOW PREVENTERBLDG - BUILDINGBOB - BOTTOM OF BEAMBOD - BOTTOM OF DUCTBOE - BOTTOM OF EQUIPMENTBOF - BOTTOM OF FOOTINGBOG - BOTTOM OF GRILLEBOP - BOTTOM OF PIPEBOT - BOTTOMBTU - BRITISH THERMAL UNITBTUH - BRITISH THERMAL UNIT PER HOUR

CBD - COUNTER BALANCED BACKDRAFT DAMPERCFCI - CONTRACTOR FURNISHED CONTRACTOR

INSTALLEDCFM - CUBIC FEET PER MINUTECHS - CHILLED WATER SUPPLYCHR - CHILLED WATER RETURNCLG - CEILINGCMU - CONCRETE MASONRY UNITCO - CLEAN OUTCO2 - CARBON DIOXIDECONN - CONNECT OR CONNECTIONCONTR - CONTRACTORCTR - CENTERCU - COPPERCW - COLD WATERCWS - CONDENSER WATER SUPPLYCWR - CONDENSER WATER RETURN

D - DRAIN LINEDB - DRY BULBDI - DEIONIZED WATERDIA - DIAMETERDIM - DIMENSIONDN - DOWNDWG - DRAWING

EA - EACH OR EXHAUST AIREAT - ENTERING AIR TEMPERATUREEC - ELECTRICAL CONTRACTOR (DIVISION 26)EJ - EXPANSION JOINTELEC - ELECTRICALELEV - ELEVATOREQUIP - EQUIPMENTET - EXPANSION TANKETR - EXISTING TO REMAINEQS - EQUIPMENT SUPPLIEREWT - ENTERING WATER TEMPERATUREEXH - EXHAUSTEXP - EXPANSIONEXT - EXTERIOREX - EXISTING

FD - FLOOR DRAIN OR FIRE DAMPERFF - FINISHED FLOOR ELEVATIONFLR - FLOORFOB - FLAT ON BOTTOMFOF - FUEL OIL FLOWFOG - FUEL OIL GAUGEFOR - FUEL OIL RETURNFOS - FUEL OIL SUPPLYFOT - FLAT ON TOPFPM - FEET PER MINUTEFS - FLOW SWITCHFSC - FIRE SUPPRESSION CONTRACTOR (DIVISION 21)FT - FEETFTG - FOOTING

G - GAS OR NATURAL GASGA - GAUGEGAL - GALLONGALV - GALVANIZEDGC - GENERAL TRADES CONTRACTORGPM - GALLONS PER MINUTE

HB - HOSE BIBBHC - HVAC CONTRACTOR (DIVISION 23)HD - HUB DRAINHG - REFRIGERANT HOT GASHP - HORSEPOWERHPC - HIGH PRESSURE CONDENSATE RETURNHPS - HIGH PRESSURE STEAM SUPPLYHR - HOURHT - HEAT TRACEHTR - HEATERHVAC - HEATING, VENTILATING, AND AIR CONDITIONINGHW - HOT WATERHWR - HEATING HOT WATER RETURNHWS - HEATING HOT WATER SUPPLY

ID - INSIDE DIAMETERINV - INVERT ELEVATIONIN - INCHES

KEC - KITCHEN EQUIPMENT CONTRACTOR

L - LENGTHLAT - LEAVING AIR TEMPERATURELAV - LAVATORYLBS - POUNDSLPC - LOW PRESSURE CONDENSATE RETURNLPS - LOW PRESSURE STEAM SUPPLYLWT - LEAVING WATER TEMPERATURE

MAX - MAXIMUMMEZZ - MEZZANINEMFR - MANUFACTURERMH - MANHOLEMIN - MINIMUM OR MINUTEMISC - MISCELLANEOUSMTD - MOUNTEDMTG - MOUNTINGMPC - MEDIUM PRESSURE CONDENSATE

RETURNMPS - MEDIUM PRESSURE STEAM SUPPLYMU - WATER MAKE-UP

NIC - NOT IN CONTRACTNOM - NOMINALNPT - NATIONAL PIPE THREADNTS - NOT TO SCALE

OA - OUTDOOR AIROBD - OPPOSED BLADE DAMPEROD - OUTSIDE DIAMETEROFCI - OWNER FURNISHED CONTRACTOR

INSTALLEDOFOI - OWNER FURNISHED OWNER INSTALLED

P - PROPANE GASPC - PLUMBING CONTRACTOR (DIVISION 22)

OR PUMPED CONDENSATE RETURNPLBG - PLUMBINGPRESS - PRESSUREPRV - PRESSURE REGULATING VALVEPSF - POUNDS PER SQUARE FOOTPSI - POUNDS PER SQUARE INCHPSIG - POUNDS PER SQUARE INCH GAUGE

RA - RETURN AIRRAD - RADIUSRCP - REFLECTED CEILING PLANRD - ROOF DRAINREC - RECESSEDREQD - REQUIREDRI - ROUGH INRL - REFRIGERANT LIQUIDROS - REVERSE OSMOSIS WATER SUPPLYROR - REVERSE OSMOSIS WATER RETURNRPM - REVOLUTIONS PER MINUTERS - REFRIGERANT SUCTION

S - SPRINKLER (WET)SA - SUPPLY AIRSAN - SANITARY OR SANITARY DRAINSCH - SCHEDULESCW - SOFT COLD WATERSHT - SHEETSPEC - SPECIFICATIONSSQ - SQUARESR - SUPPLY RISERSRV - SAFETY RELIEF VALVESS - STAINLESS STEELSTD - STANDARDSTM - STORM OR STORM DRAINAGESTRUC - STRUCTURAL OR STRUCTURESUC - SITE UTILITY CONTRACTOR

TEMP - TEMPERATURETOB - TOP OF BEAMTOD - TOP OF DUCTTOE - TOP OF EQUIPMENTTOF - TOP OF FOOTINGTOJ - TOP OF JOISTTOP - TOP OF PIPETOS - TOP OF SLAB OR TOP OF STEELTYP - TYPICAL

UNO - UNLESS NOTED OTHERWISE

V - VENTVAC - VACUUMVEL - VELOCITYVIB - VALVE IN BOXVOL - VOLUMEVTR - VENT THROUGH ROOFVR - VENT RISER

W/ - WITHW/0 - WITHOUTWB - WET BULBWCO - WALL CLEANOUT

GENERAL FLOOR PLAN NOTES

PLAN NOTE. APPLIES ONLY TO THE SHEET WHICH IT IS SHOWN UNLESSNOTED OTHERWISE.

DETAIL NOTE. APPLIES ONLY TO THE ASSOCIATED DETAIL.

3

3

A1EQUIPMENT, DEVICE, OR PLUMBING FIXTURE MARK. LETTER DESIGNATIONSREFER TO SCHEDULES.

H1 H1OR EQUIPMENT REFERENCE. LETTER DESIGNATION VARIES. REFER TOSCHEDULES.

2

1

H2

B

H2

RISER OR STACK NUMBER

DETAIL: B = DETAIL DESIGNATION H2 = SHEET WHERE DETAIL IS LOCATED

SECTION: 1 = SECTION DESIGNATION H2 = SHEET WHERE DETAIL IS LOCATED

A1 "UP TO" SYMBOL (ITEM ON FLOOR ABOVE)

APPROXIMATE DIMENSION ABOVE FINISHED FLOOR TO TOP OR BOTTOM OFEQUIPMENT, UNLESS NOTED OTHERWISE

10"

ELEV: 8' - 0"ELEV: 8' - 0"

TOD: 8' - 10"

BOD: 7' - 2"

20x20

20x20

APPROXIMATE DIMENSION ABOVE FINISHED FLOOR TO TOP OR BOTTOM OFDUCTWORK, UNLESS NOTED OTHERWISE

APPROXIMATE DIMENSION ABOVE FINISHED FLOOR TO CENTERLINE OF PIPE,UNLESS NOTED OTHERWISE

DL-1

UC 1" DOOR UNDERCUT

DOOR LOUVER. 1 = SQUARE FEET OF LOUVER.

CONNECT TO EXISTING

PIPING SYMBOLSDOUBLE LINE SINGLE LINE

BOTTOM CONNECTION (45°)

BRANCH TEE CONNECTION (NOTE: BULLHEAD TEE'S ARE NOT PERMITTED.)

DIRECTION OF PITCH

DROP

ELBOW DOWN

ELBOW UP

EXISTING PIPE TO BE REMOVED

EXISTING PIPE TO REMAIN

FLOW DIRECTION DESIGNATION

PUMP

RISE

TOP CONNECTION (45°)

TOP CONNECTION (90°)

BOTTOM CONNECTION (90°)

DD

RR

PIPE RISER

HVAC PIPING DESIGNATIONS

HEATING HOT WATER SUPPLY PIPEHWS

HEATING HOT WATER RETURN PIPEHWRDP

H

TEMPERATURE CONTROL

DIFFERENTIAL PRESSURE SENSOR. WHEN WALL MOUNTED, MOUNTING HEIGHT 46" TOMEET ADA REQUIREMENTS. WHEN MOUNTED NEXT TO WALL SWITCH COORDINATE WITHARCHITECT.

HUMIDITY SENSOR. WHEN WALL MOUNTED, MOUNTING HEIGHT 46" TO MEET ADAREQUIREMENTS. WHEN MOUNTED NEXT TO WALL SWITCH COORDINATE WITH ARCHITECT.

STATIC PRESSURE SENSOR.

SPACE TEMPERATURE SENSOR / THERMOSTAT. WHEN WALL MOUNTED, MOUNTINGHEIGHT 46" TO MEET ADA REQUIREMENTS. WHEN MOUNTED NEXT TO WALL SWITCHCOORDINATE WITH ARCHITECT.

TEMPERATURE SENSOR. WHEN WALL MOUNTED, MOUNTING HEIGHT 46" TO MEET ADAREQUIREMENTS. WHEN MOUNTED NEXT TO WALL SWITCH COORDINATE WITHARCHITECT.

CARBON DIOXIDE SENSOR. WHEN WALL MOUNTED, MOUNTING HEIGHT 46" TO MEET ADAREQUIREMENTS. WHEN MOUNTED NEXT TO WALL SWITCH COORDINATE WITH ARCHITECT.

COCARBON MONOXIDE SENSOR. WHEN WALL MOUNTED, MOUNTING HEIGHT 46" TO MEETADA REQUIREMENTS. WHEN MOUNTED NEXT TO WALL SWITCH COORDINATE WITHARCHITECT.

SP

T

S

C

DUCTWORK SYMBOLS

ROUND BRANCH DUCTWORK

12x12

12ø

12ø

12ø

CONICALFITTING

12x1212

x12

12x1

2

12ø

ACOUSTICFITTING

ACOUSTICFITTING

12x12

12x1

2

12x1

2

12x12

ADAD

D

R R

D

RECTANGULAR BRANCH DUCTWORK

SQUARE TEE WITH TURNING VANES

NOTE: ALL SQUARE ELBOWS INRECTANGULAR AND ROUND / OVALDUCTWORK SHALL BE PROVIDED WITHTURNING VANES.

15° MAX FOR DIVERGING, 30° MAX FORCONVERGING TRANSITION - ECCENTRIC

15° MAX FOR DIVERGING, 30° MAX FORCONVERGING TRANSITION - CONCENTRIC

EXISTING DUCTWORK TO REMAIN

EXISTING DUCTWORK TO REMOVED

RETURN AIR, RELIEF AIR, OR TRANSFER AIRDUCTWORK. (UP AND DOWN) RADIUSED ORSQUARE WITH TURNING VANES.

SUPPLY AIR OR OUTDOOR AIR DUCTWORK.(UP AND DOWN) RADIUSED OR SQUAREWITH TURNING VANES.

EXHAUST AIR DUCTWORK. (UP AND DOWN)RADIUSED OR SQUARE WITH TURNINGVANES.

RECTANGULAR AND ROUND / OVALDUCTWORK RISE / DROP WITH 90° RADIUSEDOR SQUARE ELBOWS AND TURNING VANES.

RADIUS ELBOW

90° SQUARE ELBOW (WITH TURNING VANES)NOTE: ALL SQUARE ELBOWS INRECTANGULAR AND ROUND DUCTWORKSHALL BE PROVIDED WITH TURNING VANES.

ACCESS DOOR OR PANEL

DUCTWORK RISE IN DIRECTION OF AIRFLOW

DUCTWORK DROP IN DIRECTION OF AIRFLOW

DUCTWORK WITH ACOUSTICAL LINER.LISTED DUCT SIZES ARE INSIDE CLEARDIMENSIONS.

RECTANGULAR ROUND / OVAL

FLEXIBLE DUCTWORK

FLEXIBLE CONNECTION

DUCTWORK CONSTRUCTED OF SPECIALMATERIAL AS NOTED

DIRECTION OF PITCH

RECTANGULAR DUCTWORK DIMENSIONS(W x H)

26x20

ROUND DUCTWORK DIMENSIONS (DIA)26ø

OVAL DUCTWORK DIMENSIONS (W x H)26x20 OV

DUCTWORK DEVICE SYMBOLS

WALL OR DUCTWORK MOUNTED AIR DEVICE. SG1 = DESIGNATION (REFERTO AIR DEVICE SCHEDULE). 20x12 = DUCT CONNECTION SIZE (IN INCHES).300 = REQUIRED CFM. 9'-0" = MOUNTING HEIGHT FROM FLOOR TO BOTTOMOF GRILLE.

A310ø300

MANUAL BALANCING VALVE DAMPER WITH LOCKING DEVICE

BACK DRAFT DAMPER

SMOKE DAMPER

COMBINATION FIRE - SMOKE DAMPER

SG120x12300

BOG: 9'-0"

BDD

A-D

SD

FS

AIR DEVICE. A3 = DESIGNATION (REFER TO FLOOR PLANS AND AIR DEVICESCHEDULE FOR VARIOUS DESIGNATIONS).10ø = NECK SIZE (IN INCHES). 300 = REQUIRED CFM. ALL AIR DEVICEDISCHARGE 4-WAY UNLESS NOTED WITH FLOW ARROWS. AIR DEVICESHOWN IS 2-WAY SIDE THROW. METHOD OF IDENTIFICATION ALSO APPLIESTO OTHER CEILING MOUNTED AIR DEVICES.

FIRE DAMPERA = TYPE (REFER TO FLOOR PLANS FOR VARIOUS TYPES)D OR S = DYNAMIC OR STATIC

CHECK VALVE

T

P

FOB

FOT

SHUTOFF VALVE (REFER TO SPECIFICATIONS FORREQUIRED TYPE BASED ON APPLICATIONS)

CONCENTRIC PIPE REDUCER

ECCENTRIC PIPE REDUCER

PRESSURE GAUGE

TEMPERATURE GAUGE OR THERMOMETER

UNION

CLEANOUT

STRAINER

STRAINER WITH A BLOW DOWN VALVE AND HOSECONNECTION

DRAIN VALVE WITH HOSE END CONNECTION

AUTOMATIC FLOW CONTROLLER WITH P/T PLUGIN AND OUT

EXPANSION JOINT

MANUAL AIR VENT

AUTOMATIC AIR VENT

PRESSURE REDUCING VALVE

2 PORT AUTOMATIC CONTROL VALVE

3 PORT AUTOMATIC CONTROL VALVE

QUICK OPENING MANUAL VALVE

VACUUM BREAKER

NEEDLE VALVE

PRESSURE AND TEMPERATURE TEST PLUG

VACUUM GAUGE WITH STOP

END CAP

GLOBE VALVE

SHUTOFF VALVE AND BOX

SHUTOFF VALVE ON RISER

A

M

M

N

V

COMBINATION SHUTOFF AND BALANCINGVALVE (REFER TO SPECIFICATIONS FORREQUIRED TYPE BASED ON APPLICATIONS)

BALL VALVE

BUTTERFLY VALVE

GATE VALVE

VALVES AND FITTINGSDOUBLE LINE SINGLE LINE

SOLENOID VALVES

SAFETY RELIEF VALVE. FOR HYDRONIC SYSTEMSPIPE DISCHARGE AIR GAPPED TO FLOOR DRAINUNLESS NOTED OTHERWISE. FOR STEAM SYSTEMSPIPE DISCHARGE TO OUTDOORS.

WATER METERM

10"

TOE: 3' - 0"

BOE: 0' - 6"

EXISTING FIRE DAMPERF/D

FIN TUBE CONVECTOR.FT1 = DESIGNATION. REFER TO SCHEDULE.15 LF = REQUIRED LINEAR FOOTAGE OF FINNED HEATING ELEMENT.2.0 GPM = FLOW RATE.

FT-115 LF

2.0 GPM

Consultants:

architects engineers planners interior designers

300 Marconi BoulevardColumbus OH 43215schooleycaldwell.com

614-628-0300614-628-0311

TF

Drawing Issue Dates

Bidding

47 THORNDIKE STREET

ARCHITECTURE | PLANNING

CAMBRIDGE, MA 02141617 | 250 6800617 | 577 9614 FAX

PARTNERSHIPGUND

REVISIONS:

CML

PROJECT NO.

REV NO DESCRIPTION DATE

8/2

4/2

01

7 1

1:2

9:2

7 A

M

C:\B

IM\M

od

el\2

014

-06

01

3.0

1-M

echa

nic

al-C

entr

al_

teg

erd

es.r

vt

08/08/2017

LEGEND, SCHEDULES,AND DETAILS

M0.01

2014-06013

TEG

Structural

SMBH1166 Dublin Road, Suite 200Columbus, Ohio 43215-1038

Mechanical, Electrical, Plumbing & FireProtection

Heapy Engineering1400 W. Dorothy LaneDayton, OH 45409-1310

Aug 15, 2017

Landscape

MKSK462 South Ludlow AlleyColumbus, Ohio 43215

COLUMBUS MAINLIBRARY

96 South Grant AvenueColumbus, OH 43215

2014-06013

NOTES:1. WALL SWITCH CONTROL BY DIV. 26.

GENERAL NOTES:A. ALL FANS SHALL BE A.M.C.A. 211 AND 311 PERFORMANCE CERTIFIED AND SHALL BEAR THE A.M.C.A. LABEL.B. SONES VALUES BASED ON A.M.C.A. 301 MEASURED AT 5 FT.C. MOTOR HORSEPOWERS LISTED SHALL BE CONSIDERED MINIMUM.

D. ROOF & WALL OPENINGS ARE APPROX. VERIFY SIZE & COORDINATE.E. COORDINATE STEEL FRAMING AROUND ROOF OPENING WHERE REQUIRED FOR DECK SUPPORT, AND WALL LINTELS FOR WALL OPENINGS.

F. REFER TO SPECS FOR VIBRATION ISOLATOR TYPES.G. WHEN APPLICABLE, REFER TO SPECS FOR SEISMIC RESTRAINTS.

FANS

MA

RK

TY

PE

(R

EF

ER

TO

SP

EC

S)

DESCRIPTION SERVICE FA

N C

FM

ST

AT

IC P

RE

SS

UR

E (

IN.

W.C

.)

AP

PR

OX

. W

HE

EL D

IAM

ET

ER

MA

XIM

UM

SO

NE

S

MOTOR

VA

RIA

BLE

FR

EQ

UE

NC

Y D

RIV

E

AP

PR

OX

. R

OO

F/W

ALL O

PE

NIN

G

VIB

RA

TIO

N IS

OLA

TO

R T

YP

E

SEISMICRESTRAINTS BASIS OF DESIGN

RE

FE

R T

O N

OT

E

HO

RS

EP

OW

ER

VO

LT

AG

E -

PH

AS

E

RE

QU

IRE

D

IM

PO

RT

AN

CE

FA

CT

OR

MA

NU

FA

CT

UR

ER

MO

DE

L

EF-37 F1 CEILING FAN TOILET 2132 70 .25 10" 3 100W 120-1 - - - - - GREENHECK SP-B110 1

DUCT CONSTRUCTION, SEALING, AND INSULATIONGENERAL NOTES:A. REFER TO SPECIFICATIONS FOR DUCT CONSTRUCTION: SHEET METAL DUCT; INTERIOR LINING; EXTERIOR INSULATION; ETC.

NOTES:

DUCT SYSTEMS.P. CON-STRUCT.

SEALCLASS

LEAKAGECLASS

S.M.A.C.N.A. CLASS.

INTERNALLYLINED

EXTERNALINSULATION

NOTINSULATED

REFERTO

NOTE

DOUBLEWALL

INSULATED

EF-37 EXHAUST DUCTWORK A 24 - -+1" - -

MA

RK

DESCRIPTION MOUNTING CF

M

HE

AT

ING

CA

PA

CIT

Y (

MB

H)

GP

M

PIP

E R

UN

OU

T S

IZE

AU

TO

VA

LV

E T

YP

E

AU

TO

VA

LV

E C

v

MO

TO

R (

HP

/WA

TT

S)

APPROX. CABINETDIMENSIONS

VIB

RA

TIO

N IS

OLA

TO

R T

YP

E SEISMIC

RESTRAINTS THERMOSTAT

RE

FE

R T

O N

OT

E

WID

TH

DE

PT

H

HE

IGH

T

RE

CE

SS

RE

QU

IRE

D

IM

PO

RT

AN

CE

FA

CT

OR

UN

IT M

OU

NT

ED

WA

LL M

OU

NT

ED

CUH-1 INVERTED VERTICAL WALL-HUNG CABINETHEATER

WALL MOUNTED 220 15 1.00 0.75" 2-WAY 0.75" 37 W 34" 10.5" 27" 0" INTERNAL - - ● - 1,3,4

CUH-2 VERTICAL CABINET ELECTRIC UNIT HEATER FLOOR MOUNTED 300 5.7 KW 0.00 0" - - .22 HP 34" 10" 26" 0" INTERNAL - - ● - 2,3,4

HOT WATER AND ELECTRIC HEATING UNITS

NOTES:1. CONTROL VALVE SHALL BE 2-POSITION FOR SEASONAL ISOLATION.2. BASIS OF DESIGN: TRANE VERTICAL CABINET - UNIT SIZE 40.

208V/60HZ/3PH. 15.9A. 1.8FLA.3. PROVIDE STARTERS AND INTEGRAL DISCONNECT.4. FAN SHALL BE ENABLED WHEN TEMPERATURE DROPS 2°F BELOW SETPOINT.

GENERAL NOTES:A. HEATING CAPACITY BASED ON 65°F ENT. AIR & 190°F ENT. WATER.B. MAXIMUM 7FT. HD. W.P.D. THRU COIL.C. MOTOR: 115V-1PH UNLESS NOTED OTHERWISE.

D. VERIFY/COORDINATE CABINET DIMENSIONS, MOUNTING & RECESS REQUIREMENTS PRIOR TO ORDERING.E. WHEN APPLICABLE, REFER TO SPECS FOR VIBRATION ISOLATION TYPES AND SEISMIC RESTRAINTS.F. RECESSED UNITS SHALL HAVE FOUR(4) SIDE OVERLAP UNLESS NOTED OTHERWISE.

G. COORDINATE LINTELS IN MASONRY WALLS FOR FULL & SEMI- RECESSED UNIT WALL OPENINGS.H. ELECTRICAL SERVICE TO 3-PHASE UNITS SHALL BE 3-WIRE UNLESS

NOTED OTHERWISE.I. 3-PHASE COIL LOADS SHALL BE DIVIDED EVENLY ACROSS EACH PHASE.

SCALE: NONE

CABINET UNIT HEATER

SHEET LISTSheet Number Sheet Name

M0.01 LEGEND, SCHEDULES, AND DETAILS

M2.1B NEW WORK AND DEMO PLANS - AREA B

GENERAL NOTESA THESE GENERAL NOTES APPLY TO ALL DIVISION 23 DRAWINGS.

B DUCTWORK AND PIPING INDICATED TO BE REMOVED SHALL BE REMOVED ANDSTUBS SHALL BE CAPPED AT THE FIRST ACTIVE (EXISTING TO REMAIN) DUCT ORPIPE ENCOUNTERED. DUCTWORK AND PIPING THAT IS AND REMAINS INACCESSIBLESHALL BE LEFT IN PLACE (ABANDONED). ENDS OF ABANDONED DUCT AND PIPESHALL BE CAPPED.

C LOCATIONS AND SIZES INDICATED FOR EXISTING ITEMS HAVE BEEN DETERMINEDFROM AVAILABLE EXISTING DRAWINGS. FIELD VERIFY EXACT LOCATIONS AND SIZESPRIOR TO PERFORMING WORK.

D REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR EXACT LOCATION OFCEILING DEVICES AND ANY SPECIAL CEILING COLOR (NON-WHITE).

E MAINTAIN REQUIRED SERVICE ACCESS SPACE AT ALL EQUIPMENT.

F PIPING ON DRAWINGS DOES NOT INDICATE ALL REQUIRED OFFSETS AND FITTINGS.HVAC CONTRACTOR SHALL INCLUDE THESE OFFSETS AND FITTINGS TO COORDINATEWITH OTHER CONTRACTORS.

G AIR VENTS SHALL BE INSTALLED ON ALL HIGH POINTS AND AS INDICATED INDETAILS. PROVIDE BALL VALVE AND THREADED CONNECTION FOR VENTING.

H FLOOR PLANS DO NOT INDICATE ALL OF THE REQUIRED VALVING, DEVICES, ETC...ON THE PIPING REQUIRED. REFER TO STANDARD DETAILS, FLUID FLOW DIAGRAMSAND SPECIFICATION FOR ADDITIONAL INFORMATION.

I ALL HVAC PIPING SHALL BE A MINIMUM OF 0.75" SIZE UNLESS NOTED OTHERWISE.

J ALL DUCTS AND PIPES TO BE RUN ABOVE CEILING. WHERE NO CEILINGS AREINSTALLED HOLD AS HIGH AS POSSIBLE TO STRUCTURE UNLESS NOTEDOTHERWISE. IN GENERAL, KEEP DUCT AND PIPING MAINS NEXT TO UNDERSIDE OFSTRUCTURE.

K RE-INSULATE DUCTWORK AND PIPING WHERE EXISTING INSULATION HAS BEENDAMAGED AND/OR REMOVED IN THE PERFORMANCE OF WORK IN THIS PROJECT.THIS INCLUDES INSULATION OF EXISTING PIPING AND DUCTWORK WHEREASBESTOS INSULATION HAS BEEN REMOVED.

L OFFSET PIPING AND DUCTWORK AS REQUIRED TO MAINTAIN ALL MANUFACTURERSRECOMMENDED CLEARANCES.

M VALVES MAY BE SHOWN IN THE HORIZONTAL FOR CLARITY. CONTRACTOR SHALLINSTALL ALL VALVES ACCORDING TO MANUFACTURERS RECOMMENDATIONS AND TOAFFORD FULL OPERABILITY AND ACCESSIBILITY.

N ALL EXPOSED WIRING SHALL BE RUN IN CONDUIT.

O ALL PENETRATIONS FOR ATC DEVICES SHALL BE REPAIRED AND REINSULATED.

P BRANCH PIPING TO UNITS SHALL BE SAME SIZE INDICATED ON UNIT SCHEDULE.

Q FIELD VERIFY EXISTING CONDITIONS DURING BIDDING PERIOD, INCLUDINGEQUIPMENT, PIPE, AND DUCT SIZES AND LOCATIONS, CLEARANCES, ETC...

R CONTRACTOR RESPONSIBLE FOR DRAINING AND REFILLING THE SYSTEM(S) ASREQUIRED TO COMPLETE THIS WORK. ANY ADDITIONAL ISOLATION VALVES ORDRAIN VALVES REQUIRED TO DO SO SHALL BE CONSIDERED PART OF THISCONTRACT.

% HUMIDITY

OFFICES / COMMON AREAS

OUTSIDE DESIGN TEMPERATURES

INTERIOR DESIGN AREA

72

DEG. F Db SUMMER

DEG. F Db WINTERDEG. F Wb SUMMER

Db

92

074

SUMMER

% HUMIDITYDb

WINTER

AMBIENT

HVAC DESIGN DATA

75

ALL OTHER AIR CONDITIONED ROOMS 7275 50% MAX FLOATING

50% MAX

Page 11: Columbus Metropolitan Library - Miscellaneous Renovations...CL / Center Line CLG Ceiling CLR Clear CMU Concrete Masonry Unit CO Clean Out COL Column COMP Composition/ Composite CONC

TT

T

C T

T

TT

T

C T

T

54

K

3.6 4.1 4.9

XI

XB

XC

XD

XE

XF

XG

XH

3.3

EXIST.EF-35

EF-37

3

3

4

24ø

14ø

14x1

2

10x8

16ø

2.5" - HWR

2" - HWR3" - HWS

2" - HWS

12x10

26x18

5

43

G

H

H.6

16

EXIST.UH

TO/FROMADDITIONAL

REHEAT COILS

1.25"

1.25"

FTH-1-302

16x1

4

16x14

1.25"

D

TYP.1

TYP.1

TYP.1

TYP.1

CUH-1

0.75"

0.75"

610ø

10ø

Elev EElevator

Elev FElevator

8

ALTERNATE #3

BASE BID

43

H

J

H.6

3.1 3.6 4.1

XA

2.9 3.3

Elev EElevator

Elev FElevator

CUH-2

43

H

J

H.6

3.1 3.6 4.1

XA

2.9 3.3

Elev EElevator

Elev FElevator

CUH-2

24ø

14x10

10x8

18x16

26x18

16ø

3"2"

2.5"2"

543

G

H

H.6

26ø

14ø

FD

TO / FROMADDITIONALREHEAT BOXES

FD FD

EXIST.UH

FD FD

TO/FROMGARAGEFINTUBE

2

1

TYP.1

TYP.1

TYP.1

1

TYP.1

5Elev E

Elevator

Elev FElevator

7

TYP.1 FTH-1-302

9

TYP.1

A

B C

Consultants:

architects engineers planners interior designers

300 Marconi BoulevardColumbus OH 43215schooleycaldwell.com

614-628-0300614-628-0311

TF

Drawing Issue Dates

Bidding

47 THORNDIKE STREET

ARCHITECTURE | PLANNING

CAMBRIDGE, MA 02141617 | 250 6800617 | 577 9614 FAX

PARTNERSHIPGUND

REVISIONS:

KEYPLAN

CML

PROJECT NO.

REV NO DESCRIPTION DATE

8/2

4/2

01

7 1

1:2

9:3

1 A

M

C:\B

IM\M

od

el\2

014

-06

01

3.0

1-M

echa

nic

al-C

entr

al_

teg

erd

es.r

vt

08/08/2017

NEW WORK AND DEMOPLANS - AREA B

M2.1B

2014-06013

TEG

Structural

SMBH1166 Dublin Road, Suite 200Columbus, Ohio 43215-1038

Mechanical, Electrical, Plumbing & FireProtection

Heapy Engineering1400 W. Dorothy LaneDayton, OH 45409-1310

Aug 15, 2017

Landscape

MKSK462 South Ludlow AlleyColumbus, Ohio 43215

COLUMBUS MAINLIBRARY

96 South Grant AvenueColumbus, OH 43215

2014-06013

SCALE: 1/8" = 1'-0"

SECOND FLOOR NEW WORK PLAN B - BASE BID5

NOTES1. EXISTING TO REMAIN.2. REMOVE DUCTWORK BACK TO THIS POINT FOR RECONNECTION IN NEW WORK.3. PROVIDE A SOLID STATE SPEED CONTROLLER FOR BALANCING PURPOSES. BALANCE TO 70

CFM. REFER TO 23 34 00 , 2.1 FOR REQUIREMENTS.4. CONNECT 6" ROUND DUCT IN VERTICAL TO 6" EXISTING DUCT WITH WYE FITTING.5. CAREFULLY REMOVE EXISTING SLOT DIFFUSER FOR RELOCATION IN NEW WORK.6. RELOCATE EXISTING SLOT DIFFUSER TO THIS LOCATION. BALANCE TO 100 CFM.7. REMOVE DUCTWORK BACK TO THIS POINT AND CAP.8. BALANCE EXISTING FAN-POWERED VAV BOX TO 720 CFM MAX COOLING.9. REMOVE AIR DEVICE.

SCALE: 1/8" = 1'-0"

FIRST FLOOR NEW WORK PLAN B1

SCALE: 1/8" = 1'-0"

HVAC LEVEL P1.5 AND P2.5 - NEW WORK - ALTERNATE #14

SCALE: 1/8" = 1'-0"

HVAC LEVEL P3.5 - NEW WORK - ALTERNATE #13

SCALE: 1/8" = 1'-0"

FIRST FLOOR DEMOLITION PLAN B2

Page 12: Columbus Metropolitan Library - Miscellaneous Renovations...CL / Center Line CLG Ceiling CLR Clear CMU Concrete Masonry Unit CO Clean Out COL Column COMP Composition/ Composite CONC

P

T

543

G

H

J

H.6

3.1 3.6 4.1 4.9X1 X2 X3

XA

2.9 3.3

EX. WH

1

5LV(2)

5LV(2)

6

5 MB

2"

5WC(2)

WC

UR

SK5

5

4" - STM

5" -

ST

M4"

- V

4"DS

4"DS

0.5"

1

ELEV.

ELEV.

1

4" VR

GARAGE

JANITOR

STORAGE

KITCHEN

WOMEN

MEN

HOMEWORK HELP

5 DF

12

12

12

13

1

0.5"DCW 0.5"DHW

NOTES1

2

3

4

5

6

7

8

9

10

11

12

13

EXISTING PIPING TO REMAIN.

THIS WORK IS ASSOCIATED WITH THE NEW VESTIBULE WITHIN LEVELS 1.5,2.5, & 3.5 OF THE GARAGE AND SHALL BE PRICED AS AN ADD ALTERNATE #1PER SPECIFICATIONS.

REMOVE EXISTING HOT WATER ROUGH-IN TO NEAREST ACTIVE MAIN ANDCAP. HOT WATER SUPPLY FOR THIS FIXTURE TO BE SUPPLIED FROM NEWWATER HEATER LOCATED IN CEILING ABOVE ADJACENT RESTROOM (SEEDWH1).

REMOVE EXISTING PLUMBING FIXTURE AND ALL ASSOCIATED TRIM, DEVICES,ETC. REMOVE SUPPLY, VENT, AND SANITARY PIPING TO POINTS INDICATEDON PLAN FOR EXTENSION IN NEW WORK.

EXISTING PLUMBING FIXTURE TO REMAIN.

EXISTING COMMERCIAL ELECTRIC WATER HEATER TO REMAIN.

REVISE, MODIFY, AND ADD TO THE EXISTING DRY PIPE FIRE SUPPRESSIONSYSTEM TO ACCOMMODATE NEW CONSTRUCTION (NEW VESTIBULESTOREFRONT/WINDOW MULLIONS). REFER TO ARCHITECTURAL DRAWINGSFOR ALL FIRE RATING REQUIREMENTS, AND CONSTRUCTION DETAILS.PROVIDE NEW SPRINKLERS AS REQUIRED TO MATCH EXISTING INSURROUNDING AREAS, AND THE APPROPRIATE DESIGN DENSITY ANDSPRINKLER SPACING REQUIRED PER NFPA 13.

REMOVE EXISTING LAVATORY/SINK. EXISTING CHECK STOPS, TRAPS, DCWSUPPLY AND SANITARY ROUGH-INS SHALL REMAIN FOR REUSE IN NEW WORK.DHW BRANCH SHALL BE REMOVED BACK TO NEAREST ACTIVE MAIN ANDCAPPED (NEW DHW SUPPLY AND ROUGH-IN TO BE PROVIDED IN NEW WORK).FOR THE EXISTING BREAKROOM SINK ALL APPLIES EXCEPT THE EXISTING P-TRAP AND SUPPLY STOPS SHALL BE REMOVED AND REPLACED PER THEPLUMBING FIXTURE DATA.

CONNECT TO EXISTING LAVATORY DCW SUPPLY AND EXTEND ABOVE CEILINGTO NEW WATER HEATER AS INDICATED.

CAREFULLY REMOVE EXISTING GARBAGE DISPOSER FOR REINSTALLATION INNEW WORK. EXISTING ELECTRICAL ROUGH-IN TO REMAIN.

PROVIDE NEW 2" SANITARY TRAPPED OUTLET EXTENDED FROM 3" SANITARYPIPING LOCATED WITHIN CHASE. PROVIDE A TRAP PRIMER (EQUAL TO"PRECISION PLUMBING PRODUCTS "PRO1-500") SUPPLIED FROM ADJACENTCOLD WATER SUPPLY WITH SUPPLY STOP, AND ROUTE THE 0.5" INDIRECTDISCHARGE INTO NEW 2" TRAPPED OUTLET.

REVISE, MODIFY, AND ADD TO THE EXISTING WET PIPE FIRE SUPPRESSIONSYSTEM TO ACCOMMODATE NEW CONSTRUCTION (NEW VESTIBULESTOREFRONT/WINDOW MULLIONS). REFER TO ARCHITECTURAL DRAWINGSFOR ALL FIRE RATING REQUIREMENTS, AND CONSTRUCTION DETAILS.PROVIDE NEW SPRINKLERS AS REQUIRED TO MATCH EXISTING INSURROUNDING AREAS, AND THE APPROPRIATE DESIGN DENSITY ANDSPRINKLER SPACING REQUIRED PER NFPA 13.

THIS WORK IS ASSOCIATED WITH THE NEW VESTIBULE INTO THE LEVEL 1GARAGE AND SHALL BE PRICED AS AN ADD ALTERNATE #3 PERSPECIFICATIONS.

543

G

H

J

H.6

3.1 3.6 4.1 4.9X1 X2 X3

XA

2.9 3.3

EX. WH

1

5 MB

2"

0.75"

4WC(2)

WC

UR

SK 4

4" - STM

5" - STM

1

6

4"SS DN1" - DHW

0.75" - DHWR

5" -

ST

M

4"VR

1"0.75"

0.5"

4"

4"DS (1110 SF)

4" (1110 SF)

4" (2045 SF)

5"(4265 SF)1

4"DS

5

5

5DF

LV(2)

LV(2)

12

13

EXIST. 1.5"SANBELOW FLOOR

KITCHENETTE

ELEV. LOBBY

0.5"

5

54.9X3

XE

XF

XG

XH

8

5

WCLV

WC

LV

SK

8

8

5

1.25"DCW DN

3"VTR 1

1

3

3

3

10

54.9X3

XI

XE

XF

XG

XH

B1

WC

1.25"DN

3"VTR

WC

1

1

B2

4

F1

HWD1

DWH1A

P2.1B

0.375"DHW

0.375"DHW

0.5"DCW 9

0.375"DHW

DISPOSER

11

5

5

43

H

J

H.6

3.1 3.6 4.1X1

XA

2.9 3.3

7

7

NOTE: WORK SHOWN ABOVE IS APPLICABLE FORGARAGE LEVELS 3.5, 2.5, AND 1.5.

2

2

B1

B2

F1

PLUMBING FIXTURE TYPESLAVATORY, 19"X16" OVAL, VITREOUS CHINA, UNDERMOUNT, OVERFLOW, NEWGRID STRAINER AND TAILPIECE. 8" CENTERS FAUCET, LEVER HANDLES, LESSPOP-UP PLUG, 1070 ASSE MIXING VALVE.DESIGN BASIS (NO EQUALS):FIXTURE: AMERICAN STANDARD "OVALYN" 0496.221 SERIES.FAUCET: DELTA "ASHLYN" 3564 SERIESSTRAINER: MCGUIRE "155"STOPS: EXISTINGTRAP: EXISTING

LAVATORY, BOWL AND PEDESTAL, 27"X22" VITREOUS CHINA, OVERFLOW, NEWGRID STRAINER AND TAILPIECE. 8" CENTERS FAUCET, LEVER HANDLES, LESSPOP-UP PLUG, 1070 ASSE MIXING VALVE.DESIGN BASIS (NO EQUALS):FIXTURE: KOHLER "MEMOIRS" K-2258-8 SERIESFAUCET: DELTA "ASHLYN" 3564 SERIESSTRAINER: MCGUIRE 155STOPS: EXISTINGTRAP: EXISTING

KITCHENETTE SINK, STAINLESS STEEL BOWL, 18"x16"x9" DEEP, 18 GAUGE,UNDERMOUNT, NEW BASKET STRAINER, TAILPIECE, AND P-TRAP. SINGLE HOLEFAUCET, SINGLE LEVER HANDLE, INTEGRAL PULL DOWN SPRAYER, CERAMICDISC. CARTRIDGE, INTEGRAL CHECK VALVES.DESIGN BASIS (NO EQUALS):FIXTURE: KOHLER "PORTSMOUTH" 18SB.9181600S.075 SERIESFAUCET: AMERICAN STANDARD "EDGEWATER" 4932.300 SERIESSTRAINER: REINSTALL EXISTING GARBAGE DISPOSERP-TRAP: ELKAY "8912"STOPS: MCGURE "BV2165" QUARTER TURN

DWH1

ET1

HWD1

PLUMBING EQUIPMENTELECTRIC WATER HEATER, STORAGE, 4.5 KW, 30 GALLONS, SHELFMOUNTED (ABOVE CEILING OF RESTROOM, SEE DETAIL THIS SHEET).ELECTRICAL: 3 KW - 480V - 1 PHASE (COORDINATE WITH ELECTRICIANPRIOR TO PURCHASE)DESIGN BASIS: AO SMTIH "DEL-30" OR EQUAL.

EXPANSION TANK, 4.4 GALLONAMTROL "ST" SERIES OR EQUAL.

HOT WATER DISPENSERSTAINLESS STEEL TANK, ADJUSTABLE THERMOSTAT, OPTIONAL FILTER(PLUS 3 EXTRA CARTRIDGES). PROVIDE QUARTER TURN STOP, TYPE "K"SOFT COPPER TUBING FROM ADJACENT SINK SUPPLY, AND BRASS HOTWATER DISPENSING FAUCET, SINGLE HANDLE, CERAMIC VALVE, SELFCLOSING.ELECTRICAL: 750 WATTS (6.25 AMPS) - 120V - 1 PHASE, PLUG & CORD.DESIGN BASIS (NO EQUALS):WATER HEATER: INSINKERATOR "HWT-F1000S" SERIESFAUCET: INSINKERATOR "F-H3300" SERIES

GENERAL NOTES

A. ALL PIPING IS ABOVE THE CEILING (AT THE UNDERSIDE OF STRUCTURE INEXPOSED STRUCTURE AREAS), UNLESS OTHERWISE NOTED.

B. REFER TO SCHEDULES, DETAILS AND DIAGRAMS FOR PIPING, PIPE SIZES ANDPIPELINE DEVICES NOT INDICATED ON THE FLOOR PLAN.

C. LOCATIONS AND SIZES OF EXISTING PIPING HAVE BEEN DETERMINED FROM AREVIEW OF EXISTING DRAWINGS AND/OR SITE INSPECTION, WHERE POSSIBLE.FIELD VERIFICATION OF EXACT LOCATIONS, ELEVATIONS, INVERTS, SIZES,DIRECTION OF FLOW, ETC. SHALL BE REQUIRED PRIOR TO BEGINNING NEW WORK.

D. ALL PIPING SHALL BE REMOVED BACK TO ACTIVE MAINS AND CAPPED, ORREMOVED BACK TO POINTS OF CONNECTION IN NEW WORK. INACCESSIBLEPIPING, WHERE SO NOTED, TO BE ABANDONED SHALL BE DISCONNECTED FROMACTIVE SYSTEMS AND CAPPED OR PLUGGED IN CONCEALED LOCATIONS.

E. NEW CONNECTIONS TO EXISTING PIPING SHALL BE WITH THE SAME SIZE AS THEEXISTING PIPING, UNLESS OTHERWISE NOTED.

F. ALL REMOVED MATERIAL AND EQUIPMENT,SO DESIGNATED BY THE OWNER,SHALL BE TURNED OVER AND PLACED WHERE DIRECTED. ALL MATERIAL ANDEQUIPMENT, WHICH THE OWNER DOES NOT WISH TO RETAIN, SHALL BECOMETHE PROPERTY OF THE CONTRACTOR RESPONSIBLE FOR THE REMOVAL.

G. WHERE PIPES ARE TO PASS THRU, ABOVE OR BEHIND EXISTING WALLS,PARTITIONS, FLOORS, ROOF OR CEILING, CUTTING, PATCHING AND REFINISHINGOF SAME SHALL BE INCLUDED IN THIS CONTRACT. CORE DRILLING AND SAWCUTTING SHALL BE UTILIZED.

1

2

2

3

3

1

4

4

5

5

6

6

AIR GAP OVER TRAPPED OUTLET BENEATH KITCHENETTE SINK.

COMBINATION TEMPERATURE-PRESSURE RELIEF VALVE.

VACUUM RELIEF VALVE.

GALVANIZED STEEL DRAIN PAN (24" SQ x 3" HIGH, SOLDEREDSEAMS, HEMMED TOP EDGE). SHELF, BRACKETS, AND/ORTHREADED ROD SHALL BE PROVIDED FROM BUILDINGSTRUCTURE. HANG SHELF MINIMUM AT 6'-6" AFF.

ROUTE DISCHARGE PIPING FROM TUBBED SHELF TO ADJACENT1.5" TRAPPED OUTLET BENEATH NEW "F1" SINK.

PROVIDE AUTOMATIC AIR VENT AT HIGH POINT OF SYSTEM.

DHW

ET1DHW1

0.5"

0.75"

0.5"

0.5"DCW

0.5"

0.75" TYPE"L" COPPER

CHECK VALVE

P

SHUTOFF VALVE (REFER TO SPECIFICATIONS FORREQUIRED TYPE BASED ON APPLICATIONS)

PRESSURE GAUGE

UNION

PRESSURE REGULATING VALVE

SHUTOFF VALVE ON RISER

BALL VALVE

BUTTERFLY VALVE

GATE VALVE

VALVES AND FITTINGSDOUBLE LINE SINGLE LINE

PLUMBING AND FIRE SUPPRESSIONPIPING DESIGNATIONS

DOMESTIC COLD WATER

DOMESTIC HOT WATER

DOMESTIC HOT WATER RETURN

EXISTING PIPE TO REMAIN

EXISTING PIPE TO BE REMOVED

SPRINKLER PIPE (DRY)

FIRE SUPPRESSION (STANDPIPE / SPRINKLER MAIN)

FIRE SERVICE

NATURAL GAS PIPE

GARAGE DRAINAGE PIPE

(OVERFLOW) SECONDARY STORM DRAINAGE PIPE

PUMP DISCHARGE PIPE

SPRINKLER PIPE (WET)

SANITARY DRAINAGE PIPE

SPRINKLER DRAIN PIPE

STORM DRAINAGE PIPE

TRAP PRIMER DISCHARGE PIPE

SANITARY SEWER VENT

DS

F

FS

G

GD

OD

PD

S

SAN

SD

STM

TP

A1

P1 P1OR

A1

OH1

2

1

P2

B

P2

GENERAL FLOOR PLAN NOTES

RISER OR STACK NUMBER

DETAIL: B = DETAIL DESIGNATION P2 = SHEET WHERE DETAIL IS LOCATED

FIRE SUPPRESSION HAZARD CLASSIFICATION AND HAZARDCLASSIFICATION GROUP

SECTION: 1 = SECTION DESIGNATION P2 = SHEET WHERE DETAIL IS LOCATED

EQUIPMENT REFERENCE. LETTER DESIGNATION VARIES. REFER TOSCHEDULES.

EQUIPMENT, DEVICE, OR PLUMBING FIXTURE MARK. LETTERDESIGNATIONS REFER TO SCHEDULES.

CONNECT TO EXISTING

PLAN NOTE. APPLIES ONLY TO THE SHEET WHICH IT IS SHOWNUNLESS NOTED OTHERWISE.

DETAIL NOTE. APPLIES ONLY TO THE ASSOCIATED DETAIL.

"UP TO" SYMBOL (ITEM ON FLOOR ABOVE)

10" 10"

ELEV: 8' - 0"ELEV: 8' - 0"

TOE: 3' - 0"

BOE: 0' - 6"

APPROXIMATE DIMENSION ABOVE FINISHED FLOOR TO TOP ORBOTTOM OF EQUIPMENT, UNLESS NOTED OTHERWISE

APPROXIMATE DIMENSION ABOVE FINISHED FLOOR TO CENTERLINEOF PIPE, UNLESS NOTED OTHERWISE

3

3

ABBREVIATIONS

AFF - ABOVE FINISHED FLOORDF - DRINKING FOUNTAIN OR WATER COOLER

OR DIESEL FUELDS - DOWN SPOUT OR SPRINKLER (DRY)

FD - FLOOR DRAINFF - FINISHED FLOOR ELEVATION

FR - FIRE RISER

G - GAS OR NATURAL GAS

HB - HOSE BIBBHD - HUB DRAIN

INV - INVERT ELEVATION

PD - PUMP DISCHARGE OR PARAPET DRAIN

SK - SINKSR - SUPPLY RISERSS - SANITARY STACK (SOIL OR WASTE) OR STM - STORM OR STORM DRAINAGE

TP - TRAP PRIMER OR TRAP PRIMER DISCHARGE

UR - URINAL

V - VENT OR SANITARY SEWER VENTVS - VENT STACKVTR - VENT THROUGH ROOFVR - VENT RISER

WC - WATER CLOSETWH - WALL HYDRANT OR WATER HEATERWS - WATER SERVICE

PIPING SYMBOLSDOUBLE LINE SINGLE LINE

BOTTOM CONNECTION (45°)

BRANCH TEE CONNECTION (NOTE: BULLHEAD TEE'S ARE NOT PERMITTED.)

DIRECTION OF PITCH

DROP

ELBOW DOWN

ELBOW UP

EXISTING PIPE TO BE REMOVED

EXISTING PIPE TO REMAIN

FLOW DIRECTION DESIGNATION

PUMP

RISE

TOP CONNECTION (45°)

TOP CONNECTION (90°)

BOTTOM CONNECTION (90°)

DD

RR

PIPE RISER

F1

FLR

EX. 1.5"VENT

EXIST.3"SAN

CONN. TO EXISTING (C.T.E.)

C.T.E.

2"

2"

1.5"

INDIRECT PIPING FROMWATER HEATER

A

B C

Consultants:

architects engineers planners interior designers

300 Marconi BoulevardColumbus OH 43215schooleycaldwell.com

614-628-0300614-628-0311

TF

Drawing Issue Dates

Bidding

47 THORNDIKE STREET

ARCHITECTURE | PLANNING

CAMBRIDGE, MA 02141617 | 250 6800617 | 577 9614 FAX

PARTNERSHIPGUND

REVISIONS:

KEYPLAN

CML

PROJECT NO.

REV NO DESCRIPTION DATE

8/2

4/2

01

7 1

0:4

9:0

3 A

M

C:\B

IM\M

ode

l\20

14-0

601

3.0

1-P

lum

bin

g-C

en

tral_

DJT

hom

pso

n.r

vt

08/08/2017

PARTIAL DEMOLITION &NEW WORK FLOOR PLANS

P2.1B

2014-06013

RRM/DJT

Structural

SMBH1166 Dublin Road, Suite 200Columbus, Ohio 43215-1038

Mechanical, Electrical, Plumbing & FireProtection

Heapy Engineering1400 W. Dorothy LaneDayton, OH 45409-1310

Aug 15, 2017

Landscape

MKSK462 South Ludlow AlleyColumbus, Ohio 43215

Main Branch

96 South Grant AvenueColumbus, OH 43215

2014-06013

SCALE: 1/8" = 1'-0"

FIRST FLOOR DEMOLITION PLAN B1

N

SCALE: 1/8" = 1'-0"

FIRST FLOOR NEW WORK PLAN2

SCALE: 1/8" = 1'-0"

SECOND FLOOR DEMOLITION PLAN3 SCALE: 1/8" = 1'-0"

SECOND FLOOR NEW WORK PLAN4 SCALE: 1/8" = 1'-0"

TYPICAL GARAGE VESTIBULE PLAN5

PLUMBING SHEET INDEXSHEET DESCRIPTION

P2.1B PARTIAL DEMOLITION & NEW WORK FLOORPLANS

SCALE: 1/8" = 1'-0"

DOMESTIC WATER HEATER PIPINGASCALE: NONE

SANITARY DIAGRAMB

N

NNN

Page 13: Columbus Metropolitan Library - Miscellaneous Renovations...CL / Center Line CLG Ceiling CLR Clear CMU Concrete Masonry Unit CO Clean Out COL Column COMP Composition/ Composite CONC

FIRE ALARM SYMBOLS

FIRE ALARM BELL & SIGNAL LIGHT (80" AFF), (# WHEN SHOWN INDICATES CANDELA RATING OF STROBE. WHEN A # IS NOTSHOWN, THE STROBE SHALL BE RATED 15 CANDELA IN CORRIDORS AND 30 CANDELA FOR ALL OTHER LOCATIONS.

ELECTRICAL SYMBOLS

EXISTING OUTLET OR DEVICE TO REMAIN. MAINTAIN EXISTING CIRCUITING.

DASH SYMBOL INDICATES PARTICULAR OUTLET OR DEVICE TO BE REMOVED AND CIRCUITRY MADE CONTINUOUSWHERE REQUIRED.

ELECTRICAL CONNECTION.

20A-125V DUPLEX RECEPTACLE, NEMA 5-20R (18" MH UNLESS NOTED OTHERWISE).

20A-125V SINGLE RECEPTACLE, NEMA 5-20R (18" MH UNLESS NOTED OTHERWISE).

SPECIAL PURPOSE RECEPTACLE. REFER TO NOTE ON PLAN.

20A-125V DOUBLE DUPLEX RECEPTACLE. NEMA 5-20R, (18" MH UNLESS NOTED OTHERWISE) TWO GANG ASSEMBLY.

20A-125V DUPLEX RECEPTACLE, NEMA 5-20R WITH BOTTOM OUTLET CONTROLLED BY WALL SWITCH. (18" MH UNLESSNOTED OTHERWISE).

20A-125V DUPLEX RECEPTACLE, NEMA 5-20R, WITH GROUND FAULT CIRCUIT INTERRUPTER (18" MH UNLESS NOTEDOTHERWISE).

20A-125V WEATHERPROOF DUPLEX RECEPTACLE, NEMA 5-20R (HORIZONTAL 18" MH UNLESS NOTED OTHERWISE) WITHTAYMAC #10310 STANDARD COVER, VERTICAL MOUNT.

20A-125V WEATHERPROOF DUPLEX RECEPTACLE, NEMA 5-20R WITH GROUND FAULT CIRCUIT INTERRUPTER (18" MHUNLESS NOTED OTHERWISE), WITH TAYMAC #20310 STANDARD COVER, VERTICAL MOUNT.

20A-125V DUPLEX RECEPTACLE, NEMA 5-20R, ON EMERGENCY POWER (18" MH UNLESS NOTED OTHERWISE).

20A-125V POWERLOCK GROUNDING TYPE RECEPTACLE, HOSPITAL USE (66" MH UNLESS NOTED OTHERWISE).

20A-125V DUPLEX PEDESTAL TYPE FLOOR RECEPTACLE, NEMA 5-20R, IN HUBBELL BA-2527 FLOOR BOX WITH SA-2525COVERPLATE AND SC-3091 HOUSING. PROVIDE CARPET FLANGE WHERE REQUIRED.

20A-125V DUPLEX RECEPTACLE, NEMA 5-20R, IN HUBBELL BA-2527 FLUSH FLOOR BOX WITH ROUND SA-3925COVERPLATE. PROVIDE CARPET FLANGE WHERE REQUIRED.

20-125V DUPLEX RECEPTACLE, NEMA 5-20R, WITH ISOLATED GROUND (18" MH UNLESS NOTED OTHERWISE).

20A-125/250V-1PH-4W SINGLE RECEPTACLE, NEMA 14-20R (18" MH UNLESS NOTED OTHERWISE).

30A-125/250V-1PH-4W SINGLE RECEPTACLE, NEMA 14-30R (18" MH UNLESS NOTED OTHERWISE).

50A-125/250V-1PH-4W SINGLE RECEPTACLE, NEMA 14-50R (18" MH UNLESS NOTED OTHERWISE).

20A-250V-3PH-4W SINGLE RECEPTACLE, NEMA 15-20R (18" MH UNLESS NOTED OTHERWISE).

30A-250V-3PH-4W SINGLE RECEPTACLE, NEMA 15-30R (18" MH UNLESS NOTED OTHERWISE).

50A-250V-3PH-4W SINGLE RECEPTACLE, NEMA 15-50R (18" MH UNLESS NOTED OTHERWISE).

JUNCTION BOX.

MULTI-OUTLET RECEPTACLES ASSEMBLY, NEMA 5-15R (SINGLE OUTLETS ON 18" CENTERS) (46" MH UNLESS NOTEDOTHERWISE).

CLOCK HANGER OUTLET, SINGLE NEMA 5-15R RECESSED IN COVER PLATE (84" MH UNLESS NOTED OTHERWISE).

SINGLE POLE SWITCH (46" MH UNLESS NOTED OTHERWISE).

TWO POLE WALL SWITCH (46" MH UNLESS NOTED OTHERWISE).

THREE-WAY WALL SWITCH (46" MH UNLESS NOTED OTHERWISE).

FOUR-WAY WALL SWITCH (46" MH UNLESS NOTED OTHERWISE).

SWITCH WITH NEON PILOT LIGHT. ONE-GANG ASSEMBLY (46" MH UNLESS NOTED OTHERWISE).

KEY OPERATED WALL SWITCH (46" MH UNLESS NOTED OTHERWISE).

LIGHTING DIMMER SWITCH (46" MH UNLESS NOTED OTHERWISE) 1000 WATTS UNLESS OTHERWISE INDICATED.

SWITCH WITH RECEPTACLE (46" MH UNLESS NOTED OTHERWISE) STANDARD TWO-GANG ASSEMBLY OF SWITCH ANDRECEPTACLE.

FLUSH FRACTIONAL HORSEPOWER MOTOR STARTER WITH NEON PILOT LIGHT. ONE-GANG ASSEMBLY (46" MH UNLESSNOTED OTHERWISE).

HP RATED WALL SWITCH (46" MH UNLESS NOTED OTHERWISE).

DISCONNECT SWITCH.

MOTOR STARTER.

COMBINATION MOTOR STARTER AND DISCONNECT SWITCH.

ELECTRIC MOTOR.

ELECTRICAL PANEL OR SWITCHBOARD PER DRAWINGS.

PULL BOX.

LINE VOLTAGE THERMOSTAT.

UNIT HEATER.

FAN COIL.

ELECTRIC BASEBOARD HEATER.

AIR CONDITIONER.

CONDENSING UNIT.

UNIT VENTILATOR.

CORD REEL.

POWER POLE.

PHOTOELECTRIC SENSOR.

LIGHTING CONTACTOR.

CEILING MOUNTED OCCUPANCY SENSOR.

WALL MOUNTED OCCUPANCY SENSOR.

CEILING MOUNTED DAYLIGHT SENSOR.

OCCUPANCY SENSOR POWER PACK.

FIRE ALARM SPEAKER & SIGNAL LIGHT (80" AFF), (# WHEN SHOWN INDICATES CANDELA RATING OF STROBE. WHEN A # ISNOT SHOWN, THE STROBE SHALL BE RATED 15 CANDELA IN CORRIDORS AND 30 CANDELA FOR ALL OTHER LOCATIONS.

FIRE ALARM CHIME & SIGNAL LIGHT (80" AFF), (# WHEN SHOWN INDICATES CANDELA RATING OF STROBE. WHEN A # IS NOTSHOWN, THE STROBE SHALL BE RATED 15 CANDELA IN CORRIDORS AND 30 CANDELA FOR ALL OTHER LOCATIONS.

FIRE ALARM HORN & SIGNAL LIGHT (80" AFF), (# WHEN SHOWN INDICATES CANDELA RATING OF STROBE. WHEN A # IS NOTSHOWN, THE STROBE SHALL BE RATED 15 CANDELA IN CORRIDORS AND 30 CANDELA FOR ALL OTHER LOCATIONS.

FIRE ALARM SIGNALING LIGHT (80" AFF), (# WHEN SHOWN INDICATES CANDELA RATING OF STROBE. WHEN A # IS NOTSHOWN, THE STROBE SHALL BE RATED 15 CANDELA IN CORRIDORS AND 30 CANDELA FOR ALL OTHER LOCATIONS.

FIRE ALARM MANUAL STATION (46" MH UNLESS NOTED OTHERWISE). SUBSCRIPT "K" INDICATES KEY OPERATED.

CEILING MOUNTED SMOKE DETECTOR.

CEILING MOUNTED HEAT DETECTOR.

DUCT MOUNTED SMOKE DETECTOR. SUBSCRIPT "S" INDICATES SUPPLY. SUBSCRIPT "R" INDICATES RETURN.

DUCT MOUNTED HEAT DETECTOR. SUBSCRIPT "S" INDICATES SUPPLY. SUBSCRIPT "R" INDICATES RETURN.

ELECTRIC RELEASE DOOR CLOSER.

ELECTRO-MAGNETIC DOOR HOLDER.

WATER FLOW SWITCH.

VALVE SUPERVISORY SWITCH.

DUCT MOUNTED DETECTOR REMOTE TEST STATION AND ALARM INDICATOR LIGHT. SUBSCRIPT "W" INDICATES WALLMOUNTED.

SMOKE DAMPER.

FIRE FIGHTER'S TELEPHONE (60" MH UNLESS NOTED OTHERWISE).

PUSHBUTTON (46" MH UNLESS NOTED OTHERWISE) EDWARDS 852 (120 VOLT).

BUZZER (90" MH UNLESS NOTED OTHERWISE) EDWARDS 340-A (120 VOLT).

4" DIAMETER (90" MH UNLESS NOTED OTHERWISE) EDWARDS "ADAPTABEL" (120 VOLT).

GF

WP

WP/GF

EM

T

IG

20A

30A

50A

20A

50A

30A

J

2

3

4

P

K

DM

R

H

UH

FC

AC

CU

UV

PP

OS

OS

DS

OP

PC

T

F15

F15

F15

F15

15

SF

CEILING MOUNTED FIRE ALARM SPEAKER.

KF

S

H

C

D

FS

V

RW

SD

FT

B

PRESSURE SWITCH.

ADDRESSABLE MODULE. SUBSCRIPT "I" INDICATES INPUT. SUBSCRIPT "C" INDICATES CONTROL.

POST INDICATOR VALVE.

KNOX BOX.

PS

AMC/I

PIV

K

FIRE ALARM CONTROL PANEL.

20A-125V DUPLEX RECEPTACLE, NEMA 5-20R (46" MH UNLESS NOTED OTHERWISE).

C

M

CR

LC

P/B

H

SS/R

S/R

ELAPSED TIME INDICATOR CLOCK (90" MH UNLESS NOTED OTHERWISE) WITH RESET SWITCH (46" MH UNLESS NOTEDOTHERWISE).

INTERCOM SYSTEM DESK MOUNTED MASTER CONTROL STATION. SUBSCRIPT "W" INDICATES WALL MOUNT (46" MHUNLESS NOTED OTHERWISE).

INTERCOM STAFF STATION (46" MH UNLESS NOTED OTHERWISE).

INTERCOM HORN TYPE SPEAKER (84" MH UNLESS NOTED OTHERWISE).

INTERCOM SPEAKER FLUSH MOUNT IN CEILING.

I

M

H

S

FACP

AV SYMBOLS WITH ELECTRICAL REQUIREMENTS

WCSCLASSROOM SOUNDFIELD SYSTEM RECEIVER/AMPLIFIER/MIXER AND WALL OUTLET (44" MH UNLESS NOTEDOTHERWISE). TWO 1-GANG BOXES WITH 0.75" CONDUIT TO ABOVE ACCESSIBLE CEILING PER DIV 26. SUBSCRIPT "W"INDICATES WALL MOUNTED ON SHELF. SOUNDFIELD SYSTEM, GROMMETED FACEPLATES AND CABLING PER DIV 27.

SH

SURFACE MOUNTED PAGING/INTERCOM SPEAKER (90" MH UNLESS NOTED OTHERWISE). SUBSCRIPT "H" INDICATESHANGING CEILING SPEAKER. 1-GANG BOX WITH 0.75" CONDUIT TO ABOVE ACCESSIBLE CEILING PER DIV 26. SPEAKER,INSTALLATION AND CABLING PER DIV 27.

MUSIC PLAY BACK SPEAKER (102" MH UNLESS NOTED OTHERWISE). 1-GANG BOX WITH 0.75" CONDUIT TO ABOVEACCESSIBLE CEILING PER DIV 26. GROMMETED FACEPLATE, SPEAKER, INSTALLATION ADJACENT TO BOX AND WIRINGPER DIV 27.

S

SHORN TYPE PAGING/INTERCOM SYSTEM SPEAKER (90" MH UNLESS NOTED OTHERWISE). 1-GANG BOX WITH 0.75" CONDUITTO ABOVE ACCESSIBLE CEILING PER DIV 26. GROMMETED FACEPLATE, SPEAKER, INSTALLATION AND WIRING PER DIV 27.

VPAGING/INTERCOM SYSTEM WALL MOUNTED SPEAKER VOLUME CONTROLLER (46" MH UNLESS NOTED OTHERWISE).1-GANG BOX AND 0.75" CONDUIT TO ABOVE ACCESSIBLE CEILING PER DIV 26. VOLUME CONTROLLER WITHFACEPLATE, INSTALLATION AND WIRING PER DIV 27.

M# X

MICROPHONE JACKPLATE (18" MH UNLESS NOTED OTHERWISE). "#"=NUMBER OF GANG, "X"=NUMBER OF JACKS IFOTHER THAN TWO (2). PROVIDE 0.75" CONDUIT FOR 1-GANG BOX OR 1" CONDUIT FOR 2-GANG AND LARGER BOX TOABOVE ACCESSIBLE CEILING PER DIV 26. JACKS, FACEPLATE AND CABLING PER DIV 27.

WCWALL MOUNTED AV SYSTEM CONTROL INTERFACE. BACKBOX (46" MH UNLESS NOTED OTHERWISE) WITH 1" CONDUITTO ABOVE ACCESSIBLE CEILING PER DIV 26. CONTROLLER WITH CABLING PER DIV 27.

SRX LOCAL SOUND REINFORCEMENT SYSTEM SPEAKER. SUBSCRIPT "X" INDICATES TYPE. REFER TO SYSTEM DIAGRAMS.

SJSPEAKER JACKPLATE (18" MH UNLESS NOTED OTHERWISE). 3-GANG BOX WITH 0.75" CONDUIT TO ABOVE ACCESSIBLECEILING PER DIV 26.

WSFWALL MOUNTED SOUNDFIELD SYSTEM SPEAKER. 1-GANG BOX WITH 1" CONDUIT TO ABOVE CEILING PER DIV 26.SPEAKER AND CABLING PER DIV 27.

PRX

WALL MOUNTED PROJECTOR. BACKBOX WITH 1-1.25" CONDUIT TO ABOVE ACCESSIBLE CEILING PER DIV 26. PROJECTOR,MOUNT AND CABLING PER DIV 27. SUBSCRIPT "X" INDICATES CONFIGURATION TYPE, REFER TO FACEPLATE DETAILS.

WALL MOUNT ELECTRIC PROJECTION SCREEN. 1-GANG BOX WITH 1" CONDUIT TO ABOVE ACCESSIBLE CEILING PERDIV 26. SCREEN AND LOW VOLTAGE CONTROL PER DIV 27.

PSE

CEILING MOUNT ELECTRIC PROJECTION SCREEN. 1-GANG BOX WITH 1" CONDUIT TO ABOVE ACCESSIBLE CEILING PER DIV26. SCREEN AND LOW VOLTAGE CONTROL PER DIV 27.

PSE

LOCAL SOUND SYSTEM SENSING MICROPHONE. 1-GANG BOX WITH 0.75" CONDUIT TO ABOVE ACCESSIBLE CEILING PERDIV 26. MICROPHONE WITH GROMMETED FACEPLATE, INSTALLATION AND WIRING PER DIV 27.SM

HM (x)HANGING MICROPHONE OUTLET. 1-GANG BOX WITH 0.75" CONDUIT TO ABOVE ACCESSIBLE CEILING PER DIV 26. SUBSCRIPT"X" INDICATES QUANTITY OF MICROPHONES IF MORE THAN ONE (1). MICROPHONE, JACK, FACEPLATE AND WIRING PER DIV27.

MAMIC/AUX WALL MOUNTED INPUT (18" MH UNLESS NOTED OTHERWISE). 2-GANG BOX WITH 0.75" CONDUIT TO ABOVEACCESSIBLE CEILING PER DIV 26. JACKS, FACEPLATE AND CABLING PER DIV 27.

MSMICROPHONE/SPEAKER WALL MOUNTED JACKPLATE (18" MH UNLESS NOTED OTHERWISE). 1-GANG BOX WITH 0.75"CONDUIT TO ABOVE ACCESSIBLE CEILING PER DIV 26. JACKS, FACEPLATE AND CABLING PER DIV 27.

MEMONITOR/EFFECTS WALL OUTLET (18" MH UNLESS NOTED OTHERWISE). 1-GANG BOX WITH 0.75" CONDUIT TO ABOVEACCESSIBLE CEILING PER DIV 26. JACKS, FACEPLATE AND WIRING PER DIV 27.

MULTI-PIN CONNECTOR WALL OUTLET (18" MH UNLESS NOTED OTHERWISE). NEMA BOX FOR 8"x8" PLATE WITH 2" CONDUITTO ABOVE ACCESSIBLE CEILING PER DIV 26. 8"x8" PLATE WITH CONNECTORS AND WIRING PER DIV 27.

MP

REMOTE POWER SWITCH OUTLET (46" MH UNLESS NOTED OTHERWISE). 1-GANG BOX WITH 0.75" CONDUIT TO ABOVEACCESSIBLE CEILING PER DIV 26. SWITCH, FACEPLATE AND WIRING PER DIV 27.

R

PPROGRAM SOURCE CABINET FOR PAGING/INTERCOM SYSTEM. TWO 1-GANG BOXES WITH 0.75" CONDUIT TO ABOVEACCESSIBLE CEILING PER DIV 26. GROMMETED FACEPLATES, CABINET, INSTALLATION AND WIRING PER DIV 27.

CAWALL MOUNTED CALL ANNUNCIATOR FOR PAGING/INTERCOM SYSTEM (90" MH UNLESS NOTED OTHERWISE). CUSTOMBACKBOX FURNISHED PER DIV 27, INSTALLED WITH 0.75" CONDUIT TO ABOVE ACCESSIBLE CEILING PER DIV 26.ANNUNCIATOR, INSTALLATION AND WIRING PER DIV 27.

COWALL MOUNTED CALL ORIGINATION SWITCH FOR PAGING/INTERCOM SYSTEM (46" MH UNLESS NOTED OTHERWISE). 1-GANGBOX WITH 0.75" CONDUIT TO ABOVE ACCESSIBLE CEILING PER DIV 26. CALL SWITCH, FACEPLATE AND WIRING PER DIV 27.

DUCT HEATER.HDH

HEB

15

W

SINGLE FACED WALL MOUNTED CLOCK (102” MH UNLESS NOTED OTHERWISE). 12” DIAMETER FACE ANALOG CLOCKUNLESS SUBSCRIPT “15” FOR 15” DIAMETER FACE ANALOG CLOCK OR “LED” FOR LED DIGITAL CLOCK. SUBSCRIPT “W”INDICATES WIREGUARD. 1-GANG BOX WITH 0.75” CONDUIT TO ABOVE ACCESSIBLE CEILING PER DIV 26.

15 DOUBLE FACED WALL MOUNTED CLOCK (102” MH UNLESS NOTED OTHERWISE). 12” DIAMETER FACE ANALOG CLOCKUNLESS SUBSCRIPT “15” FOR 15” DIAMETER FACE ANALOG CLOCK OR “LED” FOR LED DIGITAL CLOCK. 1-GANG BOX WITH0.75” CONDUIT TO ABOVE ACCESSIBLE CEILING PER DIV 26.

LOW-VOLTAGE MOMENTARY WALL SWITCH (46" MH UNLESS NOTED OTHERWISE).L

ROOF MOUNTED ANTENNA. REFER TO ANTENNA MOUNTING DETAIL FOR MORE INFORMATION. SUBSCRIPT INDICATESTYPE.

AX

SECURITY SYMBOLS WITH ELECTRICAL REQUIREMENTS

CC1

CCTV SYSTEM WALL MOUNTED CAMERA (REFER TO CAMERA SCHEDULE FOR MOUNTING HEIGHT AND CAMERASPECIFICATIONS). SUBSCRIPT "X" INDICATES ENTRY IN CAMERA SCHEDULE. 1-GANG BOX WITH 0.75" CONDUIT TOABOVE ACCESSIBLE CEILING PER DIV 26. CAMERA AND CABLING PER DIV 28.

PS1

LOCAL LOW VOLTAGE POWER SUPPLY FOR EXTERIOR CAMERA. SUBSCRIPT "X" INDICATES ASSOCIATED CAMERA.120V POWER INTO LOCAL JUNCTION BOX ABOVE CEILING AND CONNECTION TO POWER SUPPLY PER DIV 26.POWER SUPPLY MOUNTED ABOVE CEILING AND LOW VOLTAGE WIRING TO LOCAL CAMERA PER DIV 28.

ICWALL MOUNTED INTERCOM DOOR STATION (46" MH UNLESS NOTED OTHERWISE). 1-GANG BOX WITH 0.75" CONDUIT TOABOVE ACCESSIBLE CEILING PER DIV 26. INTERCOM AND CABLING PER DIV 28.

DMDOOR POSITION SWITCH WITH WIRING PER DIV 28. CONDUIT PATHWAYS FROM DOOR FRAME TO COMMON SMSJUNCTION BOX ABOVE ACCESSIBLE CEILING PER DIV 26. PROVIDE ONE CONTACT FOR EACH LEAF IN MULTI-DOOROPENINGS. REFER TO SECURITY ROUGH-IN DETAILS.

ELELECTRONIC DOOR LOCK AND INSTALLATION BY OTHERS. LOW VOLTAGE WIRING PER DIV 28. CONDUIT PATHWAYSFROM DOOR FRAME TO COMMON SMS JUNCTION BOX ABOVE ACCESSIBLE CEILING PER DIV 26. REFER TO SECURITYROUGH-IN DETAILS.

EMELECTRONIC MAG LOCK AND INSTALLATION BY OTHERS. LOW VOLTAGE WIRING PER DIV 28. CONDUIT PATHWAYSFROM DOOR FRAME TO COMMON SMS JUNCTION BOX ABOVE ACCESSIBLE CEILING PER DIV 26. REFER TO SECURITYROUGH-IN DETAILS.

ESELECTRONIC STRIKE AND INSTALLATION BY OTHERS. LOW VOLTAGE WIRING PER DIV 28. CONDUIT PATHWAYS FROMDOOR FRAME TO COMMON SMS JUNCTION BOX ABOVE ACCESSIBLE CEILING PER DIV 26. REFER TO SECURITY ROUGH-IN DETAILS.

LB

RXREQUEST TO EXIT SWITCH IN DOOR HARDWARE BY OTHERS. LOW VOLTAGE WIRING PER DIV 28. CONDUIT PATHWAYSFROM DOOR FRAME TO COMMON SMS JUNCTION BOX ABOVE ACCESSIBLE CEILING PER DIV 26. REFER TO SECURITYROUGH-IN DETAILS.

HDHANDICAP DOOR OPERATOR MOTOR ASSEMBLY BY OTHERS. 120V POWER CONNECTION AND CONDUIT FROM DOORFRAME TO COMMON SMS JUNCTION BOX ABOVE ACCESSIBLE CEILING PER DIV 26. LOW VOLTAGE WIRING ANDINTERFACE WITH SMS AND DOOR ACTUATOR BUTTONS PER DIV 28. REFER TO SECURITY ROUGH-IN DETAILS.

HA

WALL/PEDESTAL MOUNT HANDICAP DOOR ACTUATOR BUTTON, FURNISHED BY OTHERS. BOX AS REQUIRED BYSYSTEM MANUFACTURER WITH INSTALLATION AND CONDUIT TO COMMON SMS JUNCTION BOX ABOVE ACCESSIBLECEILING PER DIV 26. ALL LOW VOLTAGE WIRING AND INTERFACE WITH SMS AND DOOR MOTOR PER DIV 28. REFERTO SECURITY ROUGH-IN DETAILS.

HOFA

WALL/FLOOR MOUNTED ELECTROMAGNETIC DOOR HOLD OPEN WITH POWER SUPPLY INSTALLED BY OTHERS. 120VPOWER AND CONNECTION, BOX AS REQUIRED BY MANUFACTURER AND CONDUIT TO COMMON SMS JUNCTION BOX ABOVEACCESSIBLE CEILING PER DIV 26. LOW VOLTAGE WIRING FROM POWER SUPPLY TO HOLD OPEN AND INTERFACE WITHSMS PER DIV 28. SUBSCRIPT "FA" INDICATES DEVICES POWERED FROM FIRE ALARM SYSTEM AND INTERFACE FROM SMSTO FIRE ALARM SYSTEM REQUIRED FOR DOOR RELEASE PER DIV 28. REFER TO SECURITY ROUGH-IN DETAILS.

CR

WALL MOUNTED PROXIMITY CARD READER (46" MH UNLESS NOTED OTHERWISE). 1-GANG BOX WITH CONDUIT TOCOMMON SMS JUNCTION BOX ABOVE ACCESSIBLE CEILING PER DIV 26. CARD READER AND CABLING PER DIV 28.REFER TO SECURITY ROUGH-IN DETAILS.

CR EL

ELEVATOR CAB MOUNTED CARD READER. READER TO BE INSTALLED IN ELEVATOR CAB AS COORDINATED WITHELEVATOR CONTRACTOR. WIRING FROM CAB THRU TRAVELING CABLE TO ELEVATOR CONTROLLER IN ELEVATORMACHINE ROOM AND INTERFACE WITH ELEVATOR CONTROLLER AND SMS PER DIV 28, COORDINATE WITH ELEVATORCONTRACTOR. REFER TO SECURITY ROUGH-IN DETAILS.

KCWALL MOUNTED COMBINATION KEYPAD/CARDREADER (46" MH UNLESS NOTED OTHERWISE). 2-GANG BOX WITH 0.75"CONDUIT TO COMMON SMS JUNCTION BOX ABOVE ACCESSIBLE CEILING PER DIV 26. DEVICE AND CABLING PER DIV 28.

KWALL MOUNTED SECURITY KEYPAD ENTRY STATION (46" MH UNLESS NOTED OTHERWISE). 1-GANG BOX WITH 0.75"CONDUIT TO COMMON SMS JUNCTION BOX ABOVE ACCESSIBLE CEILING PER DIV 26. KEYPAD AND CABLING PER DIV 28.

MDWALL MOUNTED MOTION DETECTOR (90" MH UNLESS NOTED OTHERWISE). 1-GANG BOX WITH 0.75" CONDUIT TO ABOVEACCESSIBLE CEILING PER DIV 26. MOTION DETECTOR, WALL MOUNT HARDWARE, AND CABLING PER DIV 28.

PP WWALL MOUNTED PANIC/DURESS BUTTON (46" MH UNLESS NOTED OTHERWISE). 1-GANG BOX WITH 0.75" CONDUIT TOABOVE ACCESSIBLE CEILING PER DIV 26. BUTTON AND CABLING PER DIV 28.

XWALL MOUNTED SECURITY SYSTEM WIRING OUTLET MOUNTED BELOW COUNTER TOP. 2-GANG BOX WITH 2-1"CONDUITS TO COMMON SMS JUNCTION BOX ABOVE ACCESSIBLE CEILING PER DIV 26. GROMMETED FACEPLATE ANDSECURITY SYSTEM CABLING PER DIV 28.

CMWALL MOUNTED MONITOR OUTLET FOR CCTV SYSTEM (84" MH UNLESS NOTED OTHERWISE). 1-GANG BOX WITH 1"CONDUIT TO ABOVE CORRIDOR CEILING PER DIV 26. JACK, FACEPLATE AND CABLING PER DIV 28.

MICCEILING MOUNTED SECURITY/CCTV SYSTEM AUDIO MICROPHONE. 1-GANG BOX MOUNTED IN CEILING PER DIV 26.MICROPHONE AND CABLING PER DIV 28.

BR

WALL MOUNTED BIOMETRIC READER (46" MH UNLESS NOTED OTHERWISE). 2-GANG BOX WITH 0.75" CONDUIT TOCOMMON SMS JUNCTION BOX ABOVE ACCESSIBLE CEILING PER DIV 26. READER AND CABLING PER DIV 28. REFERTO SECURITY ROUGH-IN DETAILS.

X

X

MD

PB WWALL MOUNTED PUSH BUTTON FOR LOCAL ELECTRONIC DOOR RELEASE (46" MH UNLESS NOTED OTHERWISE). 1-GANGBOX WITH 0.75" CONDUIT TO ABOVE ACCESSIBLE CEILING PER DIV 26. BUTTON AND CABLING PER DIV 28.

ELECTRONIC LATCH BOLT MONITORING. HARDWARE AND INSTALLATION BY OTHERS. LOW VOLTAGE WIRING PER DIV28. CONDUIT PATHWAYS FROM DOOR FRAME TO COMMON SECURITY JUNCTION BOX ABOVE CEILING PER DIV 26.REFER TO SECURITY ROUGH-IN DETAILS.

CEILING MOUNTED MOTION DETECTOR. 1-GANG BOX MOUNTED IN CEILING PER DIV 26. DETECTOR AND CABLINGPER DIV 28.

DC

LOCAL IP BASED 2-DOOR ACCESS CONTROL PANEL SERVING LOCAL CARD READER/SECURITY CONTROLLED DOORS.LOCATE ABOVE ADJACENT ACCESSIBLE CEILING. PROVIDE DATA DROP IN 0.75" CONDUIT TO LOCAL DATA CLOSET.EXTEND 1" CONDUIT WITH DOOR SECURITY WIRING TO LOCAL SECURITY SYSTEM JUNCTION BOX. REFER TO SECURITYROUGH-IN DETAILS.

JB

SECURITY SYSTEM JUNCTION BOX TO BE LOCATED ABOVE ACCESSIBLE CEILING (MIN 6"X6"X4"). ROUTE LOCAL DOORSECURITY WIRING CONDUITS/RACEWAYS TO JUNCTION BOX. EXTEND 1" CONDUIT WITH DOOR SECURITY WIRING TOLOCAL 2-DOOR CONTROL PANEL/REMOTE DOOR CONTROL PANEL AS INDICATED ON DRAWINGS. REFER TO SECURITYROUGH-IN DETAILS.

PL

SITE POLE FOR MOUNTING SECURITY CAMERAS (REFER TO SPECIFICATIONS FOR SIZE/TYPE). PROVIDE POLE WITHCONCRETE BASE AS INDICATED ON PLANS. EXTEND AND CONNECT TO SITE CONDUIT SYSTEM AS INDICATED ONPLANS. PROVIDE NEMA 3R JUNCTION BOX AT BASE OF POLE FOR CAMERA EQUIPMENT (120V POWER SUPPLY, FIBERCONVERTERS, ETC.). REFER TO SECURITY ROUGH-IN DETAILS.

TECHNOLOGY SYMBOLS WITH ELEC. REQUIREMENTS

PWALL MOUNTED PHONE OUTLET (46" MH UNLESS NOTED OTHERWISE). BOX WITH CONDUIT TO ABOVE ACCESSIBLECEILING PER DIV 26. JACKS, FACEPLATE AND CABLE PER DIV 27. REFER TO FACEPLATE DETAILS.

XR

WALL MOUNTED AV OUTLET (84" MH UNLESS NOTED OTHERWISE). BOX WITH CONDUIT PER DIV 26. REFER TO FACEPLATEDETAILS. JACKS, FACEPLATE AND CABLING PER DIV 27. SUBSCRIPT "X" INDICATES ALTERNATE CONFIGURATION.

XV

WALL MOUNTED AV OUTLET (44" MH UNLESS NOTED OTHERWISE). BOX WITH CONDUIT PER DIV 26. REFER TO FACEPLATEDETAILS. JACKS, FACEPLATE AND CABLING PER DIV 27. SUBSCRIPT "X" INDICATES ALTERNATE CONFIGURATION.

TECHNOLOGY FLOOR BOX PER DIV 26. PROVIDE APPROPRIATE CONNECTOR PLATE AND HINGED COVER. "#"INDICATES OUTLET TYPE. SUBSCRIPT "X" INDICATES ALTERNATE CONFIGURATION. REFER TO FACEPLATE DETAILS.

#X

CONDUIT SLEEVE / FIRE RATED SLEEVE ASSEMBLY THRU WALL (1-2" SLEEVE UNLESS NOTED OTHERWISE) PER DIV 26.

WCUSTOM OUTLET IN SURFACE RACEWAY. SURFACE RACEWAY PER DIV 26. OUTLET JACKS, FACEPLATE AND CABLINGPER DIV 27.

J TELECOM BOX AND CONDUIT PER DIV 26, REFER TO PLANS.

DWALL MOUNTED VOICE/DATA OUTLET (18" MH UNLESS NOTED OTHERWISE). BOX WITH CONDUIT(S) TO ABOVE CORRIDORCEILING PER DIV 26. JACKS, FACEPLATE AND CABLE PER DIV 27. REFER TO FACEPLATE DETAILS.

XI

WALL MOUNTED AV OUTLET (18" MH UNLESS NOTED OTHERWISE). BOX WITH CONDUITS TO ABOVE ACCESSIBLECEILING PER DIV 26. REFER TO FACEPLATE DETAILS. JACKS, FACEPLATE AND CABLING PER DIV 27. SUBSCRIPT "X"INDICATES ALTERNATE CONFIGURATION.

APWALL MOUNTED WIRELESS ACCESS POINT (96” MH UNLESS NOTED OTHERWISE). BOX WITH CONDUIT TO ABOVEACCESSIBLE CEILING PER DIV 26. WAP AND CABLE PER DIV 27.

NOTE: ALL SYMBOLS AND ABBREVIATIONS ARE SUBJECT TO MODIFICATIONS ON OTHER DRAWINGS.

ALL SYMBOLS OR ABBREVIATIONS MIGHT NOTNECESSARILY BE USED ON THIS PROJECT.

ABBREVIATIONS

AAP - AREA ALARM PANEL - MEDICAL GASACC - ACCESSADJ - ADJUSTABLEAF - ARC FAULT CIRCUIT INTERRUPTERAFCI - ARC FAULT CIRCUIT INTERRUPTERAFF - ABOVE FINISHED FLOOR TO BOTTOM OF ITEMAFG - ABOVE FINISHED GRADE TO BOTTOM OF ITEMALT - ALTERNATEAP - ACCESS PANELAPPROX - APPROXIMATEARCH - ARCHITECT OR ARCHITECTURALASSY - ASSEMBLYATS - AUTOMATIC TRANSFER SWITCH

BLDG - BUILDINGBOE - BOTTOM OF EQUIPMENTBOT - BOTTOMBTWN - BETWEEN

CFCI - CONTRACTOR FURNISHED CONTRACTOR INSTALLEDCKT - CIRCUITCLG - CEILINGCMU - CONCRETE MASONRY UNITCONN - CONNECT OR CONNECTIONCONTR - CONTRACTORCORR - CORRIDORCTR - CENTER

D - DEPTHDET - DETAILDIA - DIAMETERDIM - DIMENSIONDIV - DIVISIONDN - DOWNDWG - DRAWING

EA - EACHEC - ELECTRICAL CONTRACTOR (DIVISION 26)EJ - EXPANSION JOINTELEC - ELECTRICALELEV - ELEVATION OR ELEVATOREM - EMERGENCYEQ - EQUALEQS - EQUIPMENT SUPPLIEREQUIP - EQUIPMENTETR - EXISTING TO REMAINE - EXISTINGEXP - EXPANSIONEXT - EXTERIOR

FCE - FIRE CONTROL EQUIPMENTFF - FINISHED FLOOR ELEVATIONFLR - FLOORFSC - FIRE SUPPRESSION CONTRACTOR (DIVISION 21)FT - FEETFTG - FOOTING

GC - GENERAL CONTRACTORGF - GROUND FAULT CIRCUIT INTERRUPTERGFCI - GROUND FAULT CIRCUIT INTERRUPTER OR GOVERNMENT

FURNISHED CONTRACTOR INSTALLEDGFFT - GROUND FAULT FEED THRU

HC - HVAC CONTRACTOR (DIVISION 23)HP - HORSE POWER OR HIGH POINTHVAC - HEATING, VENTILATING, AND AIR CONDITIONING

ID - INSIDE DIAMETERIN - INCHES

KEC - KITCHEN EQUIPMENT CONTRACTOR

L - LENGTHLBS - POUNDS

MAP - MASTER ALARM PANEL (MEDICAL GAS)MAX - MAXIMUMMEZZ - MEZZANINEMFR - MANUFACTURERMH - MANHOLE OR MOUNTING HEIGHT TO CENTER LINE OF ITEMMIN - MINIMUM OR MINUTEMISC - MISCELLANEOUSMTD - MOUNTEDMTG - MOUNTING

NIC - NOT IN CONTRACTNOM - NOMINALNTS - NOT TO SCALE

OD - OUTSIDE DIAMETEROFCI - OWNER FURNISHED CONTRACTOR INSTALLEDOFOI - OWNER FURNISHED OWNER INSTALLED

PC - PLUMBING CONTRACTOR (DIVISION 22)PLBG - PLUMBING

RAD - RADIUSREC - RECESSEDREQD - REQUIREDRI - ROUGH-IN

S - SURFACE MOUNTEDSC - SECURITY CONTRACTORSCH - SCHEDULESHT - SHEETSMS - SECURITY MANAGEMENT SYSTEMSPEC - SPECIFICATIONSSQ - SQUARESS - STAINLESS STEELSTD - STANDARDSTRUC - STRUCTURAL OR STRUCTURESUC - SITE UTILITY CONTRACTOR

TC - TECHNOLOGY CONTRACTORTEMP - TEMPERATURETOE - TOP OF EQUIPMENTTYP - TYPICAL

UNO - UNLESS NOTED OTHERWISE

VFD - VARIABLE FREQUENCY DRIVEVOL - VOLUME

W/ - WITHW/0 - WITHOUTWP - WEATHERPROOF

ZVC - ZONE VALVE CABINET

1

E2

B

E2DETAIL: B = DETAIL DESIGNATION

E2 = SHEET WHERE DETAIL IS LOCATED

SECTION: 1 = SECTION DESIGNATION E2 = SHEET WHERE SECTION IS LOCATED

PLAN NOTE. APPLIES ONLY TO THE SHEET WHICH IT IS SHOWN.

DETAIL NOTE. APPLIES ONLY TO THE ASSOCIATED DETAIL.

GENERAL FLOOR PLAN NOTES

WIRE & CONDUIT IN WALL OR ABOVE CEILING.

WIRE & CONDUIT IN OR BELOW SLAB OR GRADE.

EACH ARROWHEAD REPRESENTS ONE COMPLETE CIRCUIT; "X" DENOTES PANEL NAME; NUMBER(S)DENOTES CIRCUIT(S).

LADDER TRAY, 12" x 4" DEEP UNLESS NOTED OTHERWISE.

CONDUIT FOR DATA CIRCUITRY.DAT

WIRE & CONDUIT FOR FIRE ALARM CIRCUITRY.FA

WIRE & CONDUIT FOR NURSE CALL CIRCUITRY.NC

EXISTING WIRE & CONDUIT TO REMAIN.EX

CONDUIT TO BE REMOVED.

WIRE & CONDUIT FOR NIGHT LIGHT CIRCUITRY.NL

CONDUIT FOR PHONE CIRCUITRY.PHO

WIRE & CONDUIT FOR SECURITY SYSTEM CIRCUITRY.SEC

WIRE RUN IN SURFACE WIREWAY.W

CABLE MANAGEMENT SYSTEM PATHWAY.CM

X - 1,2

WIRE & CONDUIT FOR EMERGENCY CIRCUITRY.EM

WIRE & CONDUIT FOR SOUND SYSTEM CIRCUITRY.S

WIRE & CONDUIT FOR INTERCOM SYSTEM CIRCUITRY.I

WIRE & CONDUIT FOR TELEVISION SYSTEM CIRCUITRY.TV

3

3

LUMINAIRE SYMBOLS

LIGHTING FIXTURE. CAPITAL LETTER DENOTES FIXTURE TYPE, LOWER CASE LETTER DENOTESSWITCHING ARRANGEMENT.

LIGHTING FIXTURE ON NIGHT LIGHT OR EMERGENCY CIRCUIT.

EXIT LIGHTING FIXTURE, ARROWS AS INDICATED.

Aa

WIREMOLD RACEWAY, AS NOTED ON PLANS.

CABLE TRAY, 12" x 4" DEEP UNLESS NOTED OTHERWISE.

4"

4"

4"

3

3

20A-125V DUPLEX RECEPTACLE, NEMA 5-20R WITH 2 INTEGRAL USB CHARGERS (18" MH UNLESS NOTED OTHERWISE).

Consultants:

architects engineers planners interior designers

300 Marconi BoulevardColumbus OH 43215schooleycaldwell.com

614-628-0300614-628-0311

TF

Drawing Issue Dates

Record Document

47 THORNDIKE STREET

ARCHITECTURE | PLANNING

CAMBRIDGE, MA 02141617 | 250 6800617 | 577 9614 FAX

PARTNERSHIPGUND

REVISIONS:

CML

PROJECT NO.

REV NO DESCRIPTION DATE

8/3

/20

17

4:0

7:0

1 P

M

C:\B

IM\M

od

el\2

014

-06

01

3.0

1-E

lectr

ical-C

entr

al_

jjth

om

as.r

vt

06.19.2017

LEGEND AND INDEX

E0-1

2014-06013.01

Author

Structural

SMBH1166 Dublin Road, Suite 200Columbus, Ohio 43215-1038

Mechanical, Electrical, Plumbing & FireProtection

Heapy Engineering1400 W. Dorothy LaneDayton, OH 45409-1310

August 8, 2017

Landscape

MKSK462 South Ludlow AlleyColumbus, Ohio 43215

Renovation & Addition to theMain Library

96 South Grant AvenueColumbus, OH 43215

2014-06013.01

SHEET LIST ELECTRICAL RENOVATIONSheet Number Sheet Name

E0-1 LEGEND AND INDEX

E0-2 EXISTING SINGLE LINE

E0-3 SCHEDULES

E1-1 ELECTRICAL DEMOLITION

E2-1 NEW WORK LIGHTING

E3-1 NEW WORK POWER & SYSTEMS

GSutton
Text Box
Bidding Aug 15, 2017
Page 14: Columbus Metropolitan Library - Miscellaneous Renovations...CL / Center Line CLG Ceiling CLR Clear CMU Concrete Masonry Unit CO Clean Out COL Column COMP Composition/ Composite CONC

EN

VFD VFD

EN

VFD VFD

MM

M

MM

M

VFD VFD VFD VFD EN EN ENVFD VFD

2ND FLOOR

1ST FLOOR

BASEMENT

LEVEL P - 2

LEVEL P - 1

75KVAXFMR

C1

75KVAXFMR

C2

112KVAXFMR2C1

C1

C1B

100A

C2

2C1

C2B

C2A

100A

2CA1

2CA2

2CB

1B1

112KVAXFMR1B1

1BA1

1BA2

1C1

75KVAXFMR1C1

1CA1

1CA2

XFMRP2

P2

PB

ELEV EQUIP RM H

EXISTINGBUILD FIRE

PUMPMOTOR

EXISTINGJOCKEY PUMP

P1 PAXFMRP1

ELEV EQUIP RM E ELEV EQUIP RM F ELEV EQUIP RM B

BB1

XFMRBB1

BBA 1

BBA2

LB1

XFMRLB1

LBA1

LBA2

PA 1

BA1

XFMRBA1

BAA

200A

BAA 2

EM-2

EM-1

C1-A

NEW FIRE PUMP CONTROLLER

ER1

DP-OP 400AMPS

BP-2BP-1

3RD FLOOR

2ND FLOOR

1ST FLOOR

BASEMENT

LEVEL P - 2

LEVEL P - 1

C1

C1B

C2

2C1

C2B

C2A

100A

2CA1

2CA2

2CB

1B1

1BA1

1BA2

1C1

1CA1

1CA2

45KVAXFMR

P2

P2

PB

ELEV EQUIP RM A

EXISTINGBUILD FIRE

PUMPMOTOR

EXISTINGJOCKEY PUMP

P1 PA45KVAXFMR

P1

ELEV EQUIP RM E ELEV EQUIP RM F ELEV EQUIP RM H

BB1

75KVAXFMRBB1

BBA 1

BBA2

LB1

75KVAXFMRLB1

LBA1

LBA2

ELEV EQUIP RM G

PA 1

BA1

112KVAXFMRBA1

BAA1

200A

BAA 2

EM-2

EM-1

1A1

XFMR1A1

75KVA480-208Y/120

V3PH, 4W

1AA1

C1-A

NEW FIRE PUMP CONTROLLER

ER-1

DP-OP 400AMPS

BP-2BP-1

EMP2

EMB1

EMP1

SPD

SPD

SPD

SPD

75KVAXFMRT2-OP

75KVAXFMRT1-OP

XFMRM

75KVA480-120/208

M

KP

75KVAXFMRT3-OP

RT3

SPD

EM-P1

SPD

IPAC #1

XFMRIGP

7.5KVA480V-240/120

V1PH, 3W

IRRIGATIONGRINDER

PUMP "IGP"

30A D.S.FUSED AT 25A

EXISTING UTILITY SWITCHBOARD4000A, 277/480V, 3P/4W

PENTHOUSE

EXISTINGHVAC SWITCHBOARD

2500A, 277/480V, 3P/4W

PH2

RECLOSER

RECLOSER

RECLOSERCOLLECTOR BUS

PH1

XFMR PH1 PHA

AHU#1

AHU#3

AHU#4

1500 KVAUTILITY TRANS

1500 KVAUTILITY TRANS

1500 KVAUTILITY TRANS

EXISTING UTILITY SWITCHBOARD4000A, 277/480V, 3P/4W "MS1"

PH2

RECLOSER

RECLOSER

RECLOSERCOLLECTOR BUS

PH1

XFMR PH1 PHA

EXISTING FIRE PUMP600A, 277/480V,3PH,4W

MCC#3

MCC#4

MCC#2

EM-P

DP-LR1 300 AMPS

SEF3 SEF4 SEF5 SEF6

DP-ATS800AMPS 3PH-4W

XFMRT-ERP75 KVA

ERP

1500 KVAUTILITY TRANS

1500 KVAUTILITY TRANS

1500 KVAUTILITY TRANS

G

ATS-LS

ATS-LR

ATS-OP

EM-LS

G

(2) TWO EXISTING 150 KW GENERATORS480/277 VOLT, 60HZ, 3PHASE

PARALLELING GEAR

EML

250A 250A

SPD SPD

SPD

SPD

MCC#1

ELEV EQUIP RM B

XFMRT-EMP45KVA

480-208Y/1203PH-4W

SEF1 SEF2

GENERATORANNUNCIATORPANEL

N

G

N

G

N

G

E

E EE

E

E E E EE

E

E

E

EEE

EE

E

E

E E

E

E

E

E

E

E

E E

E

E

E

EEEEE

E

EE

E

E

E E

E

E

E

E

E E

EE

E

E

E

E

E E E

E

E

E

E

E

E

E

E

E

E

E

E

EE

EE

E

EE

E

EE

E E

E

E E

E

E

E

E

E

E

E

E

E

E

E

E

E E E

E

E E

E

E E

E E

E E E

E

E

E

E

E

E

E E

E

E

E E E

E E E

E

E

Consultants:

architects engineers planners interior designers

300 Marconi BoulevardColumbus OH 43215schooleycaldwell.com

614-628-0300614-628-0311

TF

Drawing Issue Dates

Record Document

47 THORNDIKE STREET

ARCHITECTURE | PLANNING

CAMBRIDGE, MA 02141617 | 250 6800617 | 577 9614 FAX

PARTNERSHIPGUND

REVISIONS:

CML

PROJECT NO.

REV NO DESCRIPTION DATE

8/3

/20

17

4:0

7:0

4 P

M

C:\B

IM\M

od

el\2

014

-06

01

3.0

1-E

lectr

ical-C

entr

al_

jjth

om

as.r

vt

06.19.2017

EXISTING SINGLE LINE

E0-2

2014-06013.01

Author

Structural

SMBH1166 Dublin Road, Suite 200Columbus, Ohio 43215-1038

Mechanical, Electrical, Plumbing & FireProtection

Heapy Engineering1400 W. Dorothy LaneDayton, OH 45409-1310

August 8, 2017

Landscape

MKSK462 South Ludlow AlleyColumbus, Ohio 43215

Renovation & Addition to theMain Library

96 South Grant AvenueColumbus, OH 43215

2014-06013.01

GSutton
Text Box
Bidding Aug 15, 2017
Page 15: Columbus Metropolitan Library - Miscellaneous Renovations...CL / Center Line CLG Ceiling CLR Clear CMU Concrete Masonry Unit CO Clean Out COL Column COMP Composition/ Composite CONC

Consultants:

architects engineers planners interior designers

300 Marconi BoulevardColumbus OH 43215schooleycaldwell.com

614-628-0300614-628-0311

TF

Drawing Issue Dates

Record Document

47 THORNDIKE STREET

ARCHITECTURE | PLANNING

CAMBRIDGE, MA 02141617 | 250 6800617 | 577 9614 FAX

PARTNERSHIPGUND

REVISIONS:

CML

PROJECT NO.

REV NO DESCRIPTION DATE

8/3

/20

17

4:0

7:0

5 P

M

C:\B

IM\M

od

el\2

014

-06

01

3.0

1-E

lectr

ical-C

entr

al_

jjth

om

as.r

vt

06.19.2017

SCHEDULES

E0-3

2014-06013.01

Author

Structural

SMBH1166 Dublin Road, Suite 200Columbus, Ohio 43215-1038

Mechanical, Electrical, Plumbing & FireProtection

Heapy Engineering1400 W. Dorothy LaneDayton, OH 45409-1310

August 8, 2017

Landscape

MKSK462 South Ludlow AlleyColumbus, Ohio 43215

Renovation & Addition to theMain Library

96 South Grant AvenueColumbus, OH 43215

2014-06013.01

32.94 kVA 34.37 kVA (95 A)

TOTAL CONNECTED ESTIMATED DEMAND

Notes: 1) EXISTING PANELBOARD, LOADS BASED UPON EXISTING CONDITIONS AND 2015 RENOVATION DRAWINGS.

Total Est. Demand: 95 A

Resistive Heat 5148 VA 100.00% 5148 VA Total Conn.: 91 A

Spare 2740 VA 100.00% 2740 VA Total Est. Demand: 34370 VA

Receptacle 3960 VA 100.00% 3960 VA Total Conn. Load: 32938 VA

Motor 21090 VA 106.79% 22522 VA

Load Classification Connected... Demand Factor Estimated... Panel Totals

Total Load: 12.07 kVA 9.78 kVA 11.09 kVA

41 Spare 20 A 1 0 VA 0 VA 1 20 A Spare 42

39 -- -- -- 1909... 1909... -- -- -- 40

37 -- -- -- 1909... 1909... -- -- -- 38

35 CUH-2 30 A 3 1909... 1909... 3 30 A CUH-2 36

33 NEW HC DOOR 1.5 20 A 1 300 VA 1909... -- -- -- 34

31 NEW HC DOOR 2.5 20 A 1 300 VA 1909... -- -- -- 32

29 NEW HC DOOR 3.5 20 A 1 180 VA 1909... 3 30 A CUH-2 30

27 EXIST Receptacle 20 A 1 360 VA 180 VA 1 20 A EXIST PROJ SCREEN 28

25 EXIST RP MOTOR 20 A 1 240 VA 720 VA 1 20 A EXIST Receptacle 26

23 EXIST TICKET GARAGE 20 A 1 180 VA 180 VA 1 20 A EXIST CAR PAY 24

21 EXIST GATE 20 A 1 300 VA 180 VA 1 20 A EXIST SECURITY 22

19 EXIST TICKET GARAGE 20 A 1 180 VA 180 VA 1 20 A EXIST SECURITY 20

17 EXIST SCREEN 20 A 1 300 VA 1000... 1 20 A EXIST DISPOSAL EXIST 18

15 -- -- -- 582 VA 582 VA -- -- -- 16

13 EXIST VAV 20 A 2 582 VA 582 VA 2 20 A EXIST VAV 14

11 -- -- -- 334 VA 334 VA -- -- -- 12

9 EXIST FC-1-5 15 A 2 334 VA 334 VA 2 15 A EXIST FC-1-6 10

7 -- -- -- 2496... 156 VA 1 20 A EXIST CUH-2 8

5 EXIST ECH-1 30 A 2 2496... 360 VA 1 20 A EXIST Receptacle 6

3 EXIST Receptacle 20 A 1 180 VA 720 VA 1 20 A EXIST Receptacle 4

1 EXIST Receptacle 20 A 1 720 VA 180 VA 1 20 A EXIST DOOR 2

CKT Circuit Description Trip PolesA B C

Poles Trip Circuit Description CKT

Voltage: 120/208 Wye-3PH-4W Mains Rating: 200 ASupply From: T-1B1 Enclosure: Type 1 Mains Type:

Location: Elec 1083 Mounting: Surface A.I.C. Rating:

Panel: 1BA2

23.2 kVA 23.39 kVA (65 A)

TOTAL CONNECTED ESTIMATED DEMAND

Notes: ) EXISTING PANELBOARD, LOADS BASED UPON EXISTING CONDITIONS AND 2015 RENOVATION DRAWINGS.

Total Est. Demand: 65 A

Total Conn.: 64 A

Spare 14160 VA 100.00% 14160 VA Total Est. Demand: 23390 VA

Receptacle 6900 VA 100.00% 6900 VA Total Conn. Load: 23202 VA

Motor 2142 VA 108.75% 2330 VA

Load Classification Connected... Demand Factor Estimated... Panel Totals

Total Load: 14.45 kVA 4.49 kVA 4.26 kVA

29 30

27 28

25 EXIST DDC ATTIC 20 A 1 180 VA 360 VA 1 20 A EXIST Receptacle... 26

23 300 VA -- -- -- 24

21 300 VA 2 20 A EXIST VAV ATTIC 22

19 NEW INST WH 20 A 1 750 VA 180 VA 1 20 A CARD READER NEW 20

17 EXIST REFRIG 20 A 1 1500... 360 VA 1 20 A EXIST Receptacle 18

15 EXIST Receptacle Toil... 20 A 1 180 VA 180 VA 1 20 A EXIST UNIT HEATER... 16

13 EXIST VAV 20 A 1 300 VA 300 VA 1 20 A EXIST VAV ATTIC 14

11 EXIST Receptacle... 20 A 1 540 VA 720 VA 1 20 A EXIST Receptacle 12

9 EXIST MICROWAVE 20 A 1 1000... 540 VA 1 20 A EXIST Receptacle 10

7 EXIST DISPOSAL 20 A 1 11300... 360 VA 1 20 A EXIST Receptacle 8

5 EXIST VAV 20 A 1 300 VA 540 VA 1 20 A EXIST Receptacle 6

3 EXIST Receptacle 20 A 1 1572... 720 VA 1 20 A EXIST Receptacle 4

1 EXIST Receptacle 20 A 1 540 VA 180 VA 1 20 A EXIST Receptacle 2

CKT Circuit Description Trip PolesA B C

Poles Trip Circuit Description CKT

Voltage: 120/208 Wye-3PH-4W Mains Rating: 100 ASupply From: T1-C1 Enclosure: Type 1 Mains Type: MB

Location: Stor 2129 Mounting: Surface A.I.C. Rating:

Panel: C1B

NOTES: 1) LUMINAIRE COLOR AND APPEARANCE TO MATCH EXISTING "A1" LUMINAIRE. 2) LUMINAIRE COLOR AND APPEARANCE TO MATCH EXISTING "A" LUMINAIRE.

LUMINAIRES

MARK

LAMPS

LO

AD

(V

A)

FIX

TU

RE

VO

LT

AG

E

MANUFACTURER CATALOG NO. DESCRIPTION

OTHERACCEPTABLE

MANUFACTURERS DIFFUSING MEDIA

TRIM COLOR MOUNTING SIZE

SE

E N

OT

E

QUANTITY

WA

TT

S / L

AM

P

VA

/ L

INE

AR

FO

OT

CA

TA

LO

G N

O.

DE

LIV

ER

ED

LU

ME

NS

COLOR WH

ITE

BLA

CK

ALU

MIN

UM

BR

ON

ZE

ST

AN

DA

RD

S-SURFACER-RECESSEDSM-STEM MTDWM-WALL MTDC-CHAIN MTD

UC-UNDER CABCS-CEIL SURFACE

DIA

ME

TE

R

WID

TH

LE

NG

TH

DE

PT

H

FLU

OR

ES

CE

NT

L.E

.D.

C-H LED 18 INCLUDED 3500K 18 Cooper Industries, Inc. LITHONIAWL4-30L-MVOLT-3500K-DIM50

SURFACE MOUNT , STEEL HOUSING,LED, OCC SENSOR WITH 50% DIMMING,, DAMP LOCATION LISTING.

CRESCENT SHAPELINEAR FACETEDREFRACTOR.

● SURFACE

R1-H LED 25 INCLUDED 3500K 25 Cooper Industries, Inc. LITHONIA 2ALL4-30L-MVOLT-LP380 RECESSED 2X4, LED SOURCE, ROLLEDSTEEL FRAME, POWDER COAT PAINT,UL IC RATING

CONCAVE DIFFUSER ● R

A1-H LED 14 INCLUDED 1000 3500K 14 277 SHAPER SHAPER340-6-DL-LED835/1/4-120/277SCSF-ERW6-GIG-FICO-DMR10

LUMINAIRE TO MATCH EXISTING A1 INAPPEARANCE.

GLASS IN GLASS,POLISHED -FROSTEDINSIDE, CLEAR OUTSIDE.

R 7" 6" 1

A-H 14 INCLUDED 1000 3500K 14 277 PORTFOLIO PORTFOLIO LD6A10D010TEERW6A10835

LUMINAIRE TO MATCH EXISTING A INAPPEARANCE.

LENSED OPTICALCHAMBER

R 7" 6" 2

X2-H LED 3 INCLUDED 3 277 DUAL-LITE DUAL-LITE EUX6R DUAL VOLTAGE, ALUMINUM HOUSING,ACRYLIC PANEL, UNIVERSAL MOUNT,DAMP LOCATION LISTING.

SURE LITE,CHLORIDE,LITHONIA

WHITE HOUSING WITHRED STENCIL LETTERS,FACES ANDDIRECTIONAL ARROWSPLAN

● ● PER PLAN 9" 13" 2.438"

4.8 kVA 4.8 kVA (6 A)

TOTAL CONNECTED ESTIMATED DEMAND

Notes: EXISTING PANELBOARD, LOADS BASED UPON EXISTING CONDITIONS AND 2015 RENOVATION DRAWINGS.

Total Est. Demand: 6 A

Total Conn.: 6 A

Total Est. Demand: 4796 VA

Spare 500 VA 100.00% 500 VA Total Conn. Load: 4796 VA

Lighting 4296 VA 100.00% 4296 VA

Load Classification Connected... Demand Factor Estimated... Panel Totals

Total Load: 2.38 kVA 0.70 kVA 1.29 kVA

29 -- -- -- 0 VA 623 VA 1 20 A EXIST Lighting 30

27 -- -- -- 0 VA 600 VA 1 20 A EXIST Lighting 28

25 SPD 30 A 3 0 VA 21 VA 1 20 A EXIST Lighting 26

23 Spare 20 A 1 0 VA 56 VA 1 20 A EXIST Lighting 24

21 Spare 20 A 1 0 VA 98 VA 1 20 A EXIST Lighting 22

19 Spare 20 A 1 0 VA 1716... 1 20 A EXIST Lighting 20

17 Spare 20 A 1 0 VA 569 VA 1 20 A EXIST 18

15 Spare 20 A 1 0 VA 0 VA 1 20 A Spare 16

13 Spare 20 A 1 0 VA 0 VA 1 20 A Spare 14

11 Spare 20 A 1 0 VA 0 VA 1 20 A Spare 12

9 Spare 20 A 1 0 VA 0 VA 1 20 A Spare 10

7 Spare 20 A 1 0 VA 35 VA 1 20 A NEW Lighting 8

5 Spare 20 A 1 0 VA 43 VA 1 20 A NEW Lighting 6

3 Spare 20 A 1 0 VA 6 VA 1 20 A NEW EXIT SIGNS 4

1 EXIST LIGHTING 20 A 1 500 VA 105 VA 1 20 A EXIST Lighting 2

CKT Circuit Description Trip PolesA B C

Poles Trip Circuit Description CKT

Voltage: 480/277 Wye-3PH-4W Mains Rating: 100 ASupply From: EM-LS Enclosure: Type 1 Mains Type: MCB

Location: Elec 1005B Mounting: Surface A.I.C. Rating: 18,000

Panel: EM-1

NOTES:1. UNIT WITH INTEGRAL THERMOSTAT.2. DWH LOCATED ABOVE CEILING IN RESTROOM.3. TOTAL OF THREE UNITS LOCATED AT 1.5, 2.5 AND 3.5 VESTIBULES.

MOTORS, STARTERS, DISCONNECTS & CONTROLS

MARK

MOTOR STARTER DISCONNECT MEANS CONTROL FEEDER

SE

E N

OT

E

NAMEPLATE

CHARACTERISTICS LOCATION

NE

MA

SIZ

E

TYPE LOCATION

FU

RN

ISH

ED

BY

TYPE LOCATION

FU

RN

ISH

ED

BY

IN

TE

RLO

CK

WIT

H M

OT

OR

NO

. B

Y E

.C.

MA

NU

AL A

T S

TA

RT

ER

IN

TE

GR

AL W

ITH

EQ

UIP

ME

NT

FU

RN

ISH

ED

BY

SE

E N

OT

E

NU

MB

ER

OF

CO

ND

UC

TO

RS

WIR

E S

IZE

GR

OU

ND

SIZ

E

CO

ND

UIT

SIZ

E

HO

RS

EP

OW

ER

(H

P)

LO

AD

(kV

A)

120V

-1P

H

208V

-1P

H

208V

-3P

H

240V

-1P

H

240V

-3P

H

277V

-1P

H

480V

-1P

H

480V

-3P

H

RO

OM

NU

MB

ER

ROOM NAME MA

NU

AL

MA

GN

ET

IC

BU

ILT

-IN

MO

TO

R O

/L

2-S

PE

ED

VF

D

SE

E N

OT

E

NE

AR

MO

TO

R

MO

TO

R C

ON

T C

EN

TE

R

EQ

UIP

CO

NT

PA

NE

L

RO

OM

NU

MB

ER

SE

E N

OT

E

DIS

C S

WIT

CH

MA

NU

AL S

TA

RT

ER

RE

CE

PT

AC

LE

FE

ED

ER

SW

OR

BR

EA

KE

R

NE

MA

TY

PE

DIS

C S

IZE

FU

SE

SIZ

E

NE

AR

MO

TO

R

MO

TO

R C

ON

T C

EN

TE

R

EQ

UIP

CO

NT

PA

NE

L

PA

NE

LB

OA

RD

SE

E N

OT

E

CUH-2 CABINET UNIT HEATER GARAGE. 5.728 ● ● ● HC ● ● HC HC 3 10 10 0.75" 1,3

DWH-R WATER HEATER REST ROOMS 3.024 ● ● ● PC ● 30 ● EC ● PC 2 12 12 .75 2

HWD1 HOT WATER DESPENSER 0.75 ● ● ● PC ● ● EC ● PC 2 12 12 .75

EF-37 EXHAUST FAN 37 1/4 0.696 ● ● ● EC ● ● EC ● EC 2 12 12 .75

277

277

38.13 kVA 35.76 kVA (43 A)

TOTAL CONNECTED ESTIMATED DEMAND

Notes: EXISTING PANELBOARD, LOADS BASED UPON EXISTING CONDITIONS AND 2015 RENOVATION DRAWINGS.

Total Est. Demand: 43 A

Total Conn.: 46 A

Spare 15540 VA 100.00% 15540 VA Total Est. Demand: 35757 VA

Receptacle 16260 VA 80.75% 13130 VA Total Conn. Load: 38131 VA

Motor 6331 VA 111.94% 7087 VA

Load Classification Connected... Demand Factor Estimated... Panel Totals

Total Load: 7.70 kVA 7.76 kVA 7.12 kVA

41 42

39 40

37 Spare 20 A 1 0 VA 38

35 Spare 20 A 1 0 VA 36

33 Spare 20 A 1 0 VA 34

31 Spare 20 A 1 0 VA 32

29 Spare 20 A 1 0 VA 30

27 Spare 20 A 1 0 VA 28

25 Spare 20 A 1 0 VA 26

23 Spare 20 A 1 0 VA 24

21 Spare 20 A 1 0 VA 22

19 Spare 20 A 1 0 VA 20

17 Spare 20 A 1 0 VA 18

15 Spare 20 A 1 0 VA 16

13 Spare 20 A 1 0 VA 14

11 Spare 20 A 1 0 VA 12

9 Spare 20 A 1 0 VA 10

7 Spare 20 A 1 0 VA 8

5 -- -- -- 7122... 6

3 -- -- -- 6252... 1512... -- -- -- 4

1 EXIST T1-C1 70 A 3 6192... 1512... 2 20 A NEW DWH-RR 2

CKT Circuit Description Trip PolesA B C

Poles Trip Circuit Description CKT

Voltage: 480/277 Wye-3PH-4W Mains Rating: 200 ASupply From: MS1 Enclosure: Type 1 Mains Type:

Location: Stor 2129 Mounting: Surface A.I.C. Rating:

Panel: C1

GSutton
Text Box
Bidding Aug 15, 2017
Page 16: Columbus Metropolitan Library - Miscellaneous Renovations...CL / Center Line CLG Ceiling CLR Clear CMU Concrete Masonry Unit CO Clean Out COL Column COMP Composition/ Composite CONC

RX

RX

RX

RX

RF

GF

GF

DM

F

F

110

F75

J

J

GF

D

F F

S

S

CC

CC

GF

GF

GF

GF

WC

J

CR

CRCC

V

V

GF

GF

D

D

60" MHD

D

J

J

J

L

F110

J

J

54

G

H

H.6

VAV

JANITOR

STORAGE

KITCHEN

WOMEN

MEN

HOMEWORK HELP

ELEV-E

ELEV-F

1

2

23

4

5

6

6

10

ALTERNATE #3

BASE BID

A

B C

Consultants:

architects engineers planners interior designers

300 Marconi BoulevardColumbus OH 43215schooleycaldwell.com

614-628-0300614-628-0311

TF

Drawing Issue Dates

Record Document

47 THORNDIKE STREET

ARCHITECTURE | PLANNING

CAMBRIDGE, MA 02141617 | 250 6800617 | 577 9614 FAX

PARTNERSHIPGUND

REVISIONS:

KEYPLAN

CML

PROJECT NO.

REV NO DESCRIPTION DATE

8/3

/20

17

4:0

7:0

6 P

M

C:\B

IM\M

od

el\2

014

-06

01

3.0

1-E

lectr

ical-C

entr

al_

jjth

om

as.r

vt

06.19.2017

ELECTRICAL DEMOLITION

E1-1

2014-06013.01

Author

Structural

SMBH1166 Dublin Road, Suite 200Columbus, Ohio 43215-1038

Mechanical, Electrical, Plumbing & FireProtection

Heapy Engineering1400 W. Dorothy LaneDayton, OH 45409-1310

August 8, 2017

Landscape

MKSK462 South Ludlow AlleyColumbus, Ohio 43215

Renovation & Addition to theMain Library

96 South Grant AvenueColumbus, OH 43215

2014-06013.01

SCALE: 1/8" = 1'-0"

FIRST FLOOR DEMOLITION PLAN B1

NOTES:

1. EXISTING CARD READER AND DOOR OPERATOR BUTTON SHALL BE RELOCATED TO NEW DOOR .2. EXISTING LUMINAIRE SHALL BE RELOCATED.3. EXISTING WALL SWITCH SHALL BE REMOVED, THREE WAY SWITCHING SHALL BE REWORKED.4. EXISTING DATA AND POWER SHALL BE RELOCATED.5. EXISTING DOOR POWER SHALL BE EXTENDED TO NEW DOOR LOCATION.6. PROVIDE TEMPORARY SUPPORT FOR ALL CEILING MOUNTED DEVICES DURING CEILING REMOVAL AND

INSTALLATION.7. EXISTING CABINET UNIT HEATER SHALL REMAIN, MAINTAIN EXISTING CIRCUIT.8. EXISTING DOOR AND OPERATOR BUTTONS TO REMAIN.9. EXISTING PUSH TO EXIT BUTTON TO REMAIN.10. EXISTING CEILING MOUNTED VESTIBULE CAMERA SHALL BE RELOCATED AS DIRECTED BY THE OWNER.

78

9

GSutton
Text Box
Bidding Aug 15, 2017
Page 17: Columbus Metropolitan Library - Miscellaneous Renovations...CL / Center Line CLG Ceiling CLR Clear CMU Concrete Masonry Unit CO Clean Out COL Column COMP Composition/ Composite CONC

L

43

G

H

H.6

EMB1 - 20

EMB1 - 20

EMB1 - 20

EMB1 - 20

L

L

L

L

L L L L L L L

1B1 - 4

L

LL

A

A

A

A

A

H3

H3

A1

A1 A A

A1

A1

A1 A

A

A A

A

A A

A

A

A

A

G G

ESNI-4

HX1

EM-1 - 22

E

EE

E

E

E

E

E

E

E

E

E

E E

E

E

E

E E E E

E

E

EE

E E

E

E E E E E E

E

E

E

E E

E

E

ELEV-E

ELEV-F

A1-H

A1-H

1B1 - 1

1B1 - 1

1B1 - 1

1B1 - 1

EMB1-20

1B1-4

1B1-4

A-H A-H

G G

1

1

2

X2-H

X2-HEM-1 - 4

EM-1 - 4

EM-1 - 22

EM-1 - 22

A-H

1B1 - 4 1B1 - 4

E E

ALTERNATE #3

BASE BID

L

L3

65.554.9 5.4X3 X4

XI

XCXD

XE

XF

XG

XH

A

2B1 - 8

A A

2B1 - 8 2B1 - 8

2B1 - 8 2B1 - 8

2B1 - 82B1 - 8

2B1 - 8

2B1 - 8 2B1 - 8

2B1 - 8EM-2 - 28

EM-2 - 28

EM-2 - 28

HX1

HX1

HX1

2B1-8

2B1-8

A

A

A

H12B1-12

H12B1-12H1

2B1-12 2B1 - 12

2B1 - 12

2B1 - 12

G2B1 - 12

E

E

E

E E

EE

E

E E

E

E

E E

E

E

E

E

E

EE

4

4

43

H

J

H.6

3.1 3.6 4.12.6 X1 X2

XA

2.9 3.3

ELEV-E

ELEV-F

R1-H

R1-H R1-H

R1-H

X2-H

X2-H

EM-1 - 6 BB1 - 13

BB1 - 13

BB1 - 13

EM-1 - 8

EM-1 - 8

ALTERNATE #1

43

H

J

H.6

3.1 3.6 4.12.6 X1 X2

XA

2.9 3.3

EM-1 - 8

HX1

C-H

C-H

C-H

C-H

C-H

EM-1 - 6

BB1 - 13

BB1 - 13

BB1 - 13

BB1 - 13

HX1

EM-1 - 8

ALTERNATE #1

A

B C

Consultants:

architects engineers planners interior designers

300 Marconi BoulevardColumbus OH 43215schooleycaldwell.com

614-628-0300614-628-0311

TF

Drawing Issue Dates

Bidding

47 THORNDIKE STREET

ARCHITECTURE | PLANNING

CAMBRIDGE, MA 02141617 | 250 6800617 | 577 9614 FAX

PARTNERSHIPGUND

REVISIONS:

KEYPLAN

CML

PROJECT NO.

REV NO DESCRIPTION DATE

8/2

4/2

01

7 1

1:1

8:3

6 A

M

C:\B

IM\M

od

el\2

014

-06

01

3.0

1-E

lectr

ical-C

entr

al_

jjth

om

as.r

vt

06.19.2017

NEW WORK LIGHTING

E2-1

2014-06013.01

Author

Structural

SMBH1166 Dublin Road, Suite 200Columbus, Ohio 43215-1038

Mechanical, Electrical, Plumbing & FireProtection

Heapy Engineering1400 W. Dorothy LaneDayton, OH 45409-1310

Aug 15, 2017

Landscape

MKSK462 South Ludlow AlleyColumbus, Ohio 43215

Renovation & Addition to theMain Library

96 South Grant AvenueColumbus, OH 43215

2014-06013.01

SCALE: 1/8" = 1'-0"

FIRST FLOOR LIGHTING PLAN - NEW WORK BASE BID & ALTERNATE1

SCALE: 1/8" = 1'-0"

SECOND FLOOR LIGHTING PLAN B -BASE BID2

SCALE: 1/8" = 1'-0"

LIGHTING TYPICAL LEVEL P3.5 - NEW WORK ALTERNATES5

NOTES:

1. RELOCATED TYPE A LUMINAIRE.2. TWO LUMINAIRE SHALL BE RELOCATED. CENTER RELOCATED LUMINAIRES

AT THE NEW ELEVATOR DOORS TO MATCH EXISTING THE TWO EXISTINGLUMINAIRES AT THE EXISTING ELEVATOR DOORS.

3. LOCATION OF RELOCATED TYPE "L" FIXTURES.4. PROVIDE CEILING MOUNTED WHITE OCCUPANCY SENSOR IN RESTROOMS.

SCALE: 1/8" = 1'-0"

0.4 - Lighting LEVELP1.5 AND P2.5 - NEW WORK ALTERNATE3

Page 18: Columbus Metropolitan Library - Miscellaneous Renovations...CL / Center Line CLG Ceiling CLR Clear CMU Concrete Masonry Unit CO Clean Out COL Column COMP Composition/ Composite CONC

RF

GF

GF

F

F

110

F75

J

J

GF

F F

S

S

GF

GF

WC

V

V

GF

GF

J

J

J

F110

J

J

J

J

J J

J

S

S

FRF

F

F

F75

75 F

F

GF

J

GF

J

FF

FFFF

S

S

UH

S

SJ J

J

UH

H

G

4

4.13.63.1

H6

3.3

DWH-3

1BA1 - 11

1BA1 - 11

1BA1 - 11

1BA1 - 15

1BA1 - 15

1BA1 - 15

1BA1 - 20

1BA1 - 11

1B1 - 7,9,11

RP

1BA2 - 25

1BA2 - 27

1BA2 - 27

1BA1 - 15

60" MH

RT3 - 7

E

E

E

E EE

E

E

E

E

E

E

E

EE

E

E E

E E

E

E

E

EE

E

E

E

ELEV-E

ELEV-F

RT2 - 93

RT2 - 9

4

5

5

8

9

E

EE

E

10

1BA1 - 11

ALTERNATE #3

E

BASE BID

E

E

EE

E

E

EE

E

EE

6

7

X3

X4

XH

XF

XDXC

XE

XG

XI

5.55 5.44.9

C1B

C1

C1B - 2

C1B - 3

C1B - 15

EF-37 C1B - 3

C1B - 18

E

E EE

EE

E

E

E

E

E

EE

E

E

EE

E

E

EE

E

E

E E

E

EXISTING TRANS.

E

GF

EF-37 C1B - 312

DWH-R

C1 - 2,4

HWD1

C1B - 19

13

C1B - 20

XAJ

H

43

4.13.63.1

H6

3.3

E

E

EE

E

EE

ELEV-E

ELEV-F

1

2

1BA2 - 29

CUH-2

1BA2 - 30,32,34

11

ALTERNATE #1

ALTERNATE #2

A

B C

Consultants:

architects engineers planners interior designers

300 Marconi BoulevardColumbus OH 43215schooleycaldwell.com

614-628-0300614-628-0311

TF

Drawing Issue Dates

Bidding

47 THORNDIKE STREET

ARCHITECTURE | PLANNING

CAMBRIDGE, MA 02141617 | 250 6800617 | 577 9614 FAX

PARTNERSHIPGUND

REVISIONS:

KEYPLAN

CML

PROJECT NO.

REV NO DESCRIPTION DATE

8/2

4/2

01

7 1

1:1

8:3

7 A

M

C:\B

IM\M

od

el\2

014

-06

01

3.0

1-E

lectr

ical-C

entr

al_

jjth

om

as.r

vt

06.19.2017

NEW WORK POWER &SYSTEMS

E3-1

2014-06013.01

Author

Structural

SMBH1166 Dublin Road, Suite 200Columbus, Ohio 43215-1038

Mechanical, Electrical, Plumbing & FireProtection

Heapy Engineering1400 W. Dorothy LaneDayton, OH 45409-1310

Aug 15, 2017

Landscape

MKSK462 South Ludlow AlleyColumbus, Ohio 43215

Renovation & Addition to theMain Library

96 South Grant AvenueColumbus, OH 43215

2014-06013.01

SCALE: 1/8" = 1'-0"

FIRST FLOOR POWER PLAN - NEW WORK BASE BID & ALTERNATE1 SCALE: 1/8" = 1'-0"

SECOND FLOOR POWER PLAN B - BASE BID2

SCALE: 1/8" = 1'-0"

POWER - TYPICAL LEVEL P1.5, P2.5 AND P3.5 - NEW WORK ALTERNATE3

NOTES:

1. CEILING MOUNTED RECEPTACLE FOR POWERED DOOR OPERATOR. LEVEL1.5 USE CIRCUIT1BA2-31, LEVEL 2.5 USE CIRCUIT 1BA2-33.

2. PROVIDE COMPLETE ROUGH-IN FOR HANDICAP DOOR OPERATOR, COORDINATE ALLREQUIREMENTS WITH EQUIPMENT SUPPLIER PRIOR TO ANY WORK.

3. RELOCATED POWER CIRCUIT FOR POWERED DOOR.4. MAINTAIN POWER TO EXISTING POWERED DOOR.5. EXISTING DOOR OPERATOR BUTTON.6. EXTEND CONTROL FOR GREEN DOOR RELEASE PUSH BUTTON AS REQUIRED FOR NEW

STORE-FRONT DOOR.7. NEW DOOR OPERATOR BUTTON.8. LOCATION FOR RELOCATED CARD READER AND DOOR OPERATOR BUTTON.9. LOCATION FOR NEW DOOR OPERATOR BUTTON.10. EXISTING CABINET UNIT HEATER TO REMAIN, MAINTAIN EXISTING CIRCUIT.11. NEW VESTIBULE CABINET UNIT HEATERS SHALL BE CIRCUITED THROUGH NEW 30A/3P

BREAKERS IN PANEL IBA2. CABINET UNIT HEATER ARE LOCATED ON LEVELS 1.5 (IBA2-30,32,34).2.5 (IBA2-35,37,39 AND 3.5 FROM (IBA2-36,38,40).

12. EXTEND CIRCUIT FROM EXISTING RESTROOM EXHAUST FAN.13. PROVIDE 120 VOLT POWER FOR NEW CARD READER AND ELECTRIC LOCK. POWER SUPPLY

TO HARDWARE SHALL BE LOCATED ABOVE ACCESSIBLE CEILING. COORDINATE ALL CONDUITAND ROUGH-IN REQUIREMENTS WITH DOOR HARDWARE SUPPLIER PRIOR TO ANY WORK.