Coiled Tbg Cmpln

  • Upload
    reborn2

  • View
    217

  • Download
    0

Embed Size (px)

Citation preview

  • 8/12/2019 Coiled Tbg Cmpln

    1/9

    SPOOLABLE INSTALLATION SEQUENC

    CONFIDENTIALITY

    This manual section is a confidential document which must not be copied in whole or in part or

    discussed with anyone outside the Schlumberger organisation.

    COILED TUBING COMPLETION

  • 8/12/2019 Coiled Tbg Cmpln

    2/9

    CONFIDENTIALITY

    This manual section is a confidential document which must not be copied in whole or in part ordiscussed with anyone outside the Schlumberger organisation.

    SPOOLABLE Completion Surface Equipment

    Surface equipment rig-up comprises coiled tubing and

    pressure control equipment generally used forconventional coiled tubing service operations

    Fig. 1. Surface equipment rig-up.

    Injector head

    Lubricator

    Coiled tubing BOP

    Gate valve

    Coiled tubing hanger

    Casing hanger

  • 8/12/2019 Coiled Tbg Cmpln

    3/9

    CONFIDENTIALITY

    This manual section is a confidential document which must not be copied in whole or in part ordiscussed with anyone outside the Schlumberger organisation.

    SPOOLABLE Completion Well Preparation

    Set bottom-hole seal assembly in existing tubing nipple

    Flapper valve (closed) provides a pressure barrier

    opens when locator seal is stung-in

    Back-pressure valve installed in tubing hanger

    Nipple down tree

    Fig. 2. Well preparation.

    Coiled tubing hanger

    Casing hanger

    Flapper valve (closed)

    Seal bore

    Sub-surface safety valve (closed)

    Production packer

    Nipple in production tubing

  • 8/12/2019 Coiled Tbg Cmpln

    4/9

    CONFIDENTIALITY

    This manual section is a confidential document which must not be copied in whole or in part ordiscussed with anyone outside the Schlumberger organisation.

    SPOOLABLE Completion BHA Preparation

    Locator seal assembly (LSA) made-up to coiled tubing

    with an external connector

    Pump-through pump-off check valve installed on LSA

    LSA is long enough to allow required tubing movement

    Fig. 3. BHA preparation.

    Coiled tubing hanger

    Casing hanger

    Locator/external connector

    Sub-surface safety valve (open)

    Locator seal assembly with pump-out plug

    Coiled tubing inside production tubing

    Flapper valve (closed)

    Lock with PBR

  • 8/12/2019 Coiled Tbg Cmpln

    5/9

    CONFIDENTIALITY

    This manual section is a confidential document which must not be copied in whole or in part ordiscussed with anyone outside the Schlumberger organisation.

    SPOOLABLE Completion Testing Components

    Run required length of coiled tubing until the first GLM

    and valve are about to leave the spool

    Make up a test pump and gauge to the valve port and testthe valve opening pressure

    Repeat as required by completion design

    Fig. 4. Testing a gas lift valve.

    Testing GLV

  • 8/12/2019 Coiled Tbg Cmpln

    6/9

    CONFIDENTIALITY

    This manual section is a confidential document which must not be copied in whole or in part ordiscussed with anyone outside the Schlumberger organisation.

    SPOOLABLE Completion Spacing Out

    With locator engaged in the seal assembly the flapper

    valve will be held open

    Find neutral point and test downhole seals

    Prepare to set coiled tubing hanger

    Coiled tubing hanger

    Casing hanger

    Valve

    SPOOLABLE safety valve

    Sub-surface safety valve (open)

    SPOOLABLE gas lift valve

    SPOOLABLE gas lift valve

    Locator in place

    Flapper valve (open)

    Fig. 5. Sting-in space out.

  • 8/12/2019 Coiled Tbg Cmpln

    7/9

    CONFIDENTIALITY

    This manual section is a confidential document which must not be copied in whole or in part ordiscussed with anyone outside the Schlumberger organisation.

    SPOOLABLE Completion Setting the CT Hanger

    Tighten the coiled tubing hanger slips and pack-off to the

    set position

    Function and pressure test the hanger

    Cut the coiled tubing and control line and rig down thecoiled tubing equipment

    Fig. 6. Setting the coiled tubing hanger.

    ,

    ,

    ,

    ,

    ,

    ,

    ,

    ,

    ,

    ,

    ,

    ,

    ,

    ,

    ,

    ,

    ,

    ,

    ,

    ,

    ,

    ,

    ,

    ,

    ,

    ,

    ,

    ,

    ,

    ,

    ,

    ,

    ,

    ,

    ,

    ,

    ,

    ,

    ,

    ,

    ,

    ,

    ,

    ,

    ,

    ,

    ,

    ,

    ,

    ,

    ,

    ,

    ,

    ,

    ,

    ,

    ,

    ,

    ,

    ,

    ,

    ,

    ,

    ,

    ,

    ,

    ,

    ,

    ,

    ,

    ,

    ,

    ,

    ,

    ,

    ,

    ,

    ,

    ,

    ,

    ,

    ,

    ,

    ,Control line hanger

    Slip actuators

    Pack-off

    Production tubing hanger

    Side-port

  • 8/12/2019 Coiled Tbg Cmpln

    8/9

    CONFIDENTIALITY

    This manual section is a confidential document which must not be copied in whole or in part ordiscussed with anyone outside the Schlumberger organisation.

    SPOOLABLE Completion Control Line Hanger

    Control line cut above CT

    Control line is fed through the hanger and hanger is

    placed on the CT

    Hanger housing is placed over the hanger and made-upto the coiled tubing hanger

    Top of assembly is plugged and tested

    Fig. 7. Setting the control line hanger.

    , ,

    , ,

    , ,

    , ,

    , ,

    , ,

    , ,

    , ,

    , ,

    , ,

    , ,

    , ,

    , ,

    , ,

    , ,

    , ,

    ,

    ,

    ,

    ,

    ,

    ,

    ,

    ,

    Guides

    Coiled tubing

    Plug profile

    Control line shear ram

    Control line port

  • 8/12/2019 Coiled Tbg Cmpln

    9/9

    CONFIDENTIALITY

    This manual section is a confidential document which must not be copied in whole or in part ordiscussed with anyone outside the Schlumberger organisation

    SPOOLABLE Completion Completion Configuration

    With the test plug in place rig down the CT equipment and

    nipple up the tree

    Retrieve the test plug with slick-line and prepare to turnwell to production

    Coiled tubing hanger

    Casing hanger

    SPOOLABLE safety valve

    Sub-surface safety valve (open)

    SPOOLABLE gas lift valve

    SPOOLABLE gas lift valve

    Locator in place

    Flapper valve (open)

    Fig. 8. Completion in place.

    Valve

    Control line hanger