Put a sample of 2.00 ml in a vial, heat it for 15 minutes, select the
program and finally read the results displayed after the COD analysis is
complete.
TECHNOCRACY PVT. LTD.
®
TECHNOCRACY PVT. LTD.®
ACMAS TECHNOCRACY PVT. LTD.www.measuring-meters.com | www.acmasindia.com | www.scientificlaboratoryequipments.com
• Wastewater • Ecology
• Study of freshwater ponds and lakes • Analysts and modelers working with
determination of water quality.
Chemical Oxygen Demand (COD) is the laboratory measurement of amount of oxygen used in chemical reactions that occur in water as a result of
the addition of wastes to it. It measures the sum total of organic and inorganic pollution in waste water.
COD is a measure of the relative oxygen-depletion effect of a waste contaminant in water. It is an essentially a laboratory test which acts as
wastewater quality indicator and will have a significant adverse effect aquatic life in water.
Measurement of COD in
www.measuring-meters.com
ACMAS TECHNOCRACY PVT. LTD.www.measuring-meters.com | www.acmasindia.com | www.scientificlaboratoryequipments.com
Chemical Oxygen Demand (COD)ANALYSIS SYSTEM
ACMAS TECHNOCRACY PVT. LTD.www.measuring-meters.com | www.acmasindia.com | www.scientificlaboratoryequipments.com
Chemical Oxygen Demand (COD)ANALYSIS SYSTEM
• Temperature for: • COD - 165°C • TP / TN - 105°C
• Capacity : 24 vials of size 16 x 100 mm
• Warm up Time : 20 minutes
• Power Requirements : 220±22V, 50Hz, 300W
• Ambient Operating : 0 to 50 ?
Temperature
• Temperature Stability : ±1?
• Accuracy : ±1?
• Timer : 1-1680 minutes(31 hours) with audible alarm
And feature of being automatic
• Range Adjustment : 105-165±1?, Shortcuts for 105? and 150?
WORKING PRINCIPLE
Put a sample of 2.00 ml in a vial, heat it for 15 minutes, select the program and finally read the results displayed after the COD analysis is
complete.
Ground water : Every 3 months
Lakes : Every 2 months
River : Every 2 weeks
FREQUENCY OF MEASUREMENT
• Transparent Protective Lid
• Auto Shutdown at End of Completion of the Procedure
Product Features:
Technical Features:
Our Fast Response COD analysis system works on the principle of oxidation of oxidisable material with a given amount of potassium chromate,
the titration of excess chromate and the calculation of oxygen consumed.
TECHNOCRACY PVT. LTD.
®
TECHNOCRACY PVT. LTD.®
ACMAS TECHNOCRACY PVT. LTD.www.measuring-meters.com | www.acmasindia.com | www.scientificlaboratoryequipments.com
SALES OFFICE (INDIA)
312-313, Vardhman Capital Mall, L.S.C. 10, GulabiBagh, Delhi-110052, INDIA
Tel: 0091-11-23646703, 23643054
(M) +91-9313971681| Email: [email protected]
SALES OFFICE (HONG KONG)
Unit D 28 11/f Wing Tat Comm, Bldg 97, Bonham Strand East, Sheung Wan, HONG KONG (PRC).
Tel: 0086-13929598046 | 0086-18922303099
Email: [email protected]
SHOWROOM
141, Rai Industrial Estate, Rai, Sonepat, Haryana-131029, INDIA
Tel: 0091-0-9312219738 (M) +91-9717741167
Email: [email protected]
SALES OFFICE (RUSSIA)
Inmed Trade Street, Ozerkovsky Embankment, Unit No 50 Straine-1, Off-502, Moscow, RUSSIA
Tel: 0049-79592345 | Email: [email protected]
www.measuring-meters.com | www.acmasindia.com | www.scientificlaboratoryequipments.com
TECHNOCRACY PVT. LTD.