  • Rf. : CM.6106.M2 Rev : 14NORMES DE CONCEPTIONDESIGN STANDARD

    Ce document comporte21 pages

    Page 1

    COPYRIGHT OF AKER YARDS S.A. ALL RIGHTS RESERVED.NO PART THEREOF MAY BE DISCLOSED, COPIED, DUPLICATED OR IN ANY OTHER WAY MADE USE OF, EXCEPT WITH THE PRIOR APPROVAL OF AKER YARDS S.A

    DECOUPURES DES PORTES ET BAIESDOORS AND PICTURE WINDOWS CUTOUTS

    OBJET PURPOSE

    Cette Norme de Conception a pour objet de dfinirles critres de choix des dcoupures ainsi que lesprincipes de construction autour des portes etbaies dans les cloisons mtalliques (structurellesou non).

    The purpose of this Design standard is to setout the choice criteria of cutouts and theconstruction principles around doors and picturewindows in steel bulkheads (structural or not).

    DOMAINE DAPPLICATION SCOPE OF APPLICATION

    Tous navires All ships

    APPROBATIONS SOCIETES DECLASSIFICATION

    APPROVALS BY CLASSIFICATIONSOCIETIES

    sans no

    ApprobationsRev : 14

    Rdacteur

    Nom : Bernard MOYONFonction : Dessinateur

    Vrificateur

    Nom : Soazig LOUAZELFonction :Responsable Qualit Etude

    Le 11/12/06 le 11/12/06

    Modifications de la rvision 14 :

    Page 16, modifier les cas 1 et 2. (Dtails des dlardages sur les inserts de portes type 7 et type 8) Pages 18 21, modifier le chapitre 4 Intgration des dcoupures

    Page 16, to modify the cases 1 and 2. (Details of the taperings on the inserts of doors type 7 and type 8) Pages 18 to 21, to modify the chapter 4 " Cutouts integration ",

  • Rf. : CM.6106.M2 Rev : 14NORMES DECONCEPTION

    DESIGNSTANDARD

    DECOUPURES DES PORTES ET BAIESDOORS AND PICTURE WINDOWS

    CUTOUTS Ce document comporte21 pagesPage

    2

    COPYRIGHT OF AKER YARDS S.A. ALL RIGHTS RESERVED.NO PART THEREOF MAY BE DISCLOSED, COPIED, DUPLICATED OR IN ANY OTHER WAY MADE USE OF, EXCEPT WITH THE PRIOR APPROVAL OF AKER YARDS S.A

    SOMMAIRESUMMARY

    Objet / Domaine dapplicationPurpose / Scope of application

    1

    SommaireSummary

    2

    1. GUIDE POUR LE CHOIX DES DECOUPURESGUIDE FOR THE CHOICE OF CUTOUTS

    4

    1.1 Portes contraintes faibles ou leves.Doors low stresses or high stresses.

    4

    1.2 Baies contraintes faibles ou leves.Picture windows low stresses or high stresses.

    5

    1.3 Portes et baies contraintes trs leves.Doors and picture windows very high stresses.

    5

    2. ZONES NECESSITANT UNE ATTENTION PARTICULIEREAREAS REQUIRING A SPECIFIC ATTENTION

    6

    2.1 Dcoupures superposesSuperposed cutouts

    6

    2.2 Dcoupures rapproches dans une cloisonCutouts close together in a bulkhead

    7

    2.3 Dcoupures sous pontilleCutouts under pillar

    8

    2.4 Dcoupures sous paroi longitudinale de structureCutouts under longitudinal structural shell

    8

    2.5 Dcoupures dans une cloison soumise la contrainte densembleCutouts in a bulkhead submitted to the overall stress

    9

    2.6 Dcoupures proches dun dcroisement de structureCutouts near a structural staggering

    9

    2.7 Dcoupures dans une zone fortement solliciteCutouts in a heavy stressed area

    10

    3. GEOMETRIE DES DECOUPURESCUTOUTS GEOMETRY

    11

    3.1 Dcoupure type 1Cutout type 1

    11

    3.2 Dcoupure type 2Cutout type 2

    11

    3.3 Dcoupure type 3Cutout type 3

    12

    3.4 Dcoupure type 4Cutout type 4

    12

    3.5 Dcoupure type 5Cutout type 5

    13

    3.6 Dcoupure type 6Cutout type 6

    13

  • Rf. : CM.6106.M2 Rev : 14NORMES DECONCEPTION

    DESIGNSTANDARD

    DECOUPURES DES PORTES ET BAIESDOORS AND PICTURE WINDOWS

    CUTOUTS Ce document comporte21 pagesPage

    3

    COPYRIGHT OF AKER YARDS S.A. ALL RIGHTS RESERVED.NO PART THEREOF MAY BE DISCLOSED, COPIED, DUPLICATED OR IN ANY OTHER WAY MADE USE OF, EXCEPT WITH THE PRIOR APPROVAL OF AKER YARDS S.A

    3.7 Dcoupure type 7Cutout type 7

    14

    3.8 Dcoupure type 8Cutout type 8

    15

    3.9 Dtails de dlardages sur les inserts de portes type 7 et type 8Details of taperings on the inserts of doors type7 and type 8

    16

    4. INTEGRATION DES DECOUPURESCUTOUTS INTEGRATION

    18

    4.1 Cloison transversale de structureTransverse structural bulkhead

    18

    4.2 Cloison longitudinale de structure et cloison plane demmnagementLongitudinal structural bulkhead and plan accomodation bulkhead

    18

    4.3 Cas particulierSpecific case

    19

  • Rf. : CM.6106.M2 Rev : 14NORMES DECONCEPTION

    DESIGNSTANDARD

    DECOUPURES DES PORTES ET BAIESDOORS AND PICTURE WINDOWS

    CUTOUTS Ce document comporte21 pagesPage

    4

    COPYRIGHT OF AKER YARDS S.A. ALL RIGHTS RESERVED.NO PART THEREOF MAY BE DISCLOSED, COPIED, DUPLICATED OR IN ANY OTHER WAY MADE USE OF, EXCEPT WITH THE PRIOR APPROVAL OF AKER YARDS S.A

    Si contrainteslevesIf highstresses

    1. GUIDE POUR LE CHOIX DES DECOUPURESGUIDE FOR THE CHOICE OF CUTOUTS

    1.1 Portes contraintes faibles ou leves.Doors low stresses or high stresses.

    Types de porte :Doors types :F porte mtallique incendie fire steel doorM MO porte mtallique ordinaire ordinary steel door ME porte mtallique tanche aux embruns steel door watertight to sea sprayT porte en teck door in teckW porte tanche extrieure outside watertight door

    PORTESDOORS

    Porte mtalliqueincendie F

    Steel fire door F

    Porte mtallique MSteel door M

    Porte Teck TTeck door

    tanche auxembruns ME

    watertight to seaspray

    battanteswing

    coulissantesliding

    ordinaire MOMO ordinary

    Porte tancheextrieure WWatertight

    outside door M

    avec surbauwith

    coaming

    sans surbauwithout

    coaming

    Type 4 Type 5Type 2Type 1Type 6 Type 3

    Type 2Type 7 Type 7Type 8

  • Rf. : CM.6106.M2 Rev : 14NORMES DECONCEPTION

    DESIGNSTANDARD

    DECOUPURES DES PORTES ET BAIESDOORS AND PICTURE WINDOWS

    CUTOUTS Ce document comporte21 pagesPage

    5

    COPYRIGHT OF AKER YARDS S.A. ALL RIGHTS RESERVED.NO PART THEREOF MAY BE DISCLOSED, COPIED, DUPLICATED OR IN ANY OTHER WAY MADE USE OF, EXCEPT WITH THE PRIOR APPROVAL OF AKER YARDS S.A

    1.2 Baies contraintes faibles ou leves.Pictures windows low stresses or high stresses.

    1.3 Portes et baies contraintes trs leves. Doors and pictures windows very high stresses

    Les dcoupures sont valables pour les cloisons de structure et les cloisons demmnagement. On ne tient pas compte des options contraintes leves ou contraintes trs leves pour les cloisons EM.

    Les zones avec des contraintes leves ou trs leves seront traites par le groupe Calcul dICE sur le plateau navire.

    Cutouts are valid for structural bulkheads and accomodation bulkheads. The options high stresses or very high stresses for accomodation bulkheads are not taken into account.

    High stressed areas or very high stressed areas will be treated by ICE Calculation team on the ship stage.

    Type 2

    Type 1

    contraintes levesheavy stresses

    Contraintes faiblesLow stresses

    BAIESPICTURE WINDOWS

    TOUS TYPES DE PORTES ET BAIESALL TYPES OF DOORS ANDPICTURE WINDOWS

    Type 7

  • Rf. : CM.6106.M2 Rev : 14NORMES DECONCEPTION

    DESIGNSTANDARD

    DECOUPURES DES PORTES ET BAIESDOORS AND PICTURE WINDOWS

    CUTOUTS Ce document comporte21 pagesPage

    6

    COPYRIGHT OF AKER YARDS S.A. ALL RIGHTS RESERVED.NO PART THEREOF MAY BE DISCLOSED, COPIED, DUPLICATED OR IN ANY OTHER WAY MADE USE OF, EXCEPT WITH THE PRIOR APPROVAL OF AKER YARDS S.A

    2. ZONES NECESSITANT UNE ATTENTION PARTICULIEREAREAS REQUIRING A SPECIFIC ATTENTION

    2.1 Dcoupures superposesSuperimposed cutouts

    Nota : dans ce cas de figure, lpaisseur de la tle environnant la dcoupure sera majore pouranticiper les dcoupures TU VC EL situes au-dessus de la porte, et sera prcise sur le plande structure.

    Note : in this case, the thickness of the plate environning the cutout will be increased in order toanticipate the TU VC EL cutouts located above the door and will be mentioned on thestructural drawing.

    POUR CHAQUE CAS, CONSULTER LE PILOTE DU CALCUL DENSEMBLEAFIN DE DETERMINER LES EPAISSEURS ET VALIDER LA DECOUPURE.

    FOR EVERY CASE, CONSULT THE OVERALL ANALYSIS PILOT TO FIX THETHICKNESSES AND TO VALIDATE THE CUTOUT.

  • Rf. : CM.6106.M2 Rev : 14NORMES DECONCEPTION

    DESIGNSTANDARD

    DECOUPURES DES PORTES ET BAIESDOORS AND PICTURE WINDOWS

    CUTOUTS Ce document comporte21 pagesPage

    7

    COPYRIGHT OF AKER YARDS S.A. ALL RIGHTS RESERVED.NO PART THEREOF MAY BE DISCLOSED, COPIED, DUPLICATED OR IN ANY OTHER WAY MADE USE OF, EXCEPT WITH THE PRIOR APPROVAL OF AKER YARDS S.A

    2.2 Dcoupures rapproches dans une cloisonCutouts close together in a bulkhead

    Nota : lorsquune dcoupure interfre avec le primtre trac 1500 autour dune autredcoupure, consulter le pilote du calcul densemble.

    Note : when a cutout interfers with the perimeter drawn 1500 around another cutout, consultthe overall analysis pilot.

    Primtre de 1500 autour de ladcoupure1500 perimeter around thecutout

  • Rf. : CM.6106.M2 Rev : 14NORMES DECONCEPTION

    DESIGNSTANDARD

    DECOUPURES DES PORTES ET BAIESDOORS AND PICTURE WINDOWS

    CUTOUTS Ce document comporte21 pagesPage

    8

    COPYRIGHT OF AKER YARDS S.A. ALL RIGHTS RESERVED.NO PART THEREOF MAY BE DISCLOSED, COPIED, DUPLICATED OR IN ANY OTHER WAY MADE USE OF, EXCEPT WITH THE PRIOR APPROVAL OF AKER YARDS S.A

    2.3 Dcoupure sous pontilleCutout under pillar

    Voir avec le pilote du calcul densemble queltype de dcoupure doit tre retenu (T1, T2,).See with the overall analysis pilot what type of cutout has to be retained (T1, T2,).

    2.4 Dcoupure sous paroi longitudinale de structureCutout under longitudinal structural shell

    Voir avec le pilote du calcul densemble queltype de dcoupure doit tre retenu (T1, T2,).See with the overall analysis pilot what type

    of cutout has to be retained (T1, T2,).

    Zone de diffusion des effortsArea of forces diffusion

    Lorsquune dcoupure interfre avec la zone dediffusion des efforts, adapter lpaisseur et leraidissage des cloisons sous lpontille.When a cutout interfers with the area of forcesdiffusion, adapt the thickness and the stiffeningof the bulkheads under the pillar.

    1tg =

    2,5

    1tg =

    2,5

    Lorsquune dcoupure interfre avec la zone dediffusion des efforts, adapter lpaisseur et leraidissage des cloisons .When a cutout interfers with the area of forcesdiffusion, adapt the thickness and the stiffeningof the bulkheads.

  • Rf. : CM.6106.M2 Rev : 14NORMES DECONCEPTION

    DESIGNSTANDARD

    DECOUPURES DES PORTES ET BAIESDOORS AND PICTURE WINDOWS

    CUTOUTS Ce document comporte21 pagesPage

    9

    COPYRIGHT OF AKER YARDS S.A. ALL RIGHTS RESERVED.NO PART THEREOF MAY BE DISCLOSED, COPIED, DUPLICATED OR IN ANY OTHER WAY MADE USE OF, EXCEPT WITH THE PRIOR APPROVAL OF AKER YARDS S.A

    2.5 Dcoupures dans une cloison soumise la contrainte densembleCutouts in a bulkhead submitted to the overall stress

    Voir avec le pilote du calcul densemble quel type dedcoupure doit tre retenu (T2, T7,).See with the overall analysis pilot what type of cutouthas to be retained (T2, T7,).

    2.6 Dcoupures proches dun dcroisement de structureCutouts near a structural staggering

    Voir avec le pilote du calcul densemble quel type dedcoupure doit tre retenu (T2, T7,..).See with the overall analysis pilot what type of cutouthas to be retained (T2, T7,).

    Contrainte verticaleVertical stress

    ContraintehorizontaleHorizontal

    stressContrainte decisaillementShear stress

  • Rf. : CM.6106.M2 Rev : 14NORMES DECONCEPTION

    DESIGNSTANDARD

    DECOUPURES DES PORTES ET BAIESDOORS AND PICTURE WINDOWS

    CUTOUTS Ce document comporte21 pagesPage

    10

    COPYRIGHT OF AKER YARDS S.A. ALL RIGHTS RESERVED.NO PART THEREOF MAY BE DISCLOSED, COPIED, DUPLICATED OR IN ANY OTHER WAY MADE USE OF, EXCEPT WITH THE PRIOR APPROVAL OF AKER YARDS S.A

    2.7 Dcoupures dans une zone fortement solliciteCutouts in a high stressed area

    P

    M

    Mt radar Ft de grueRadar mast Crane shaft

    Lorsquune dcoupure interfre avec la zonede diffusion des efforts, voir avec le pilote ducalcul densemble quel type de dcoupure doittre retenu (T2, T7,.). When a cutoutinterfers with the area of forces diffusion, seewith the overall analysis pilot what type ofcutout has to be retained (T2, T7,).

  • Rf. : CM.6106.M2 Rev : 14NORMES DECONCEPTION

    DESIGNSTANDARD

    DECOUPURES DES PORTES ET BAIESDOORS AND PICTURE WINDOWS

    CUTOUTS Ce document comporte21 pagesPage

    11

    COPYRIGHT OF AKER YARDS S.A. ALL RIGHTS RESERVED.NO PART THEREOF MAY BE DISCLOSED, COPIED, DUPLICATED OR IN ANY OTHER WAY MADE USE OF, EXCEPT WITH THE PRIOR APPROVAL OF AKER YARDS S.A

    3. GEOMETRIE DES DECOUPURESCUTOUTS GEOMETRY

    3.1 Dcoupure Type 1Cutout type 1

    h et b dfinis par AC ou HLP h and b defined by AC or HLP

    3.2 Dcoupure Type 2Cutout type 2

    h et b dfinis par AC ou HLP et ICE h and b defined by AC or HLP and ICE

    b

    h

    R80

    b

    h

    R60

    10

    15

    40

    20

    rfrence largeur dcoupurereference cutout width

  • Rf. : CM.6106.M2 Rev : 14NORMES DECONCEPTION

    DESIGNSTANDARD

    DECOUPURES DES PORTES ET BAIESDOORS AND PICTURE WINDOWS

    CUTOUTS Ce document comporte21 pagesPage

    12

    COPYRIGHT OF AKER YARDS S.A. ALL RIGHTS RESERVED.NO PART THEREOF MAY BE DISCLOSED, COPIED, DUPLICATED OR IN ANY OTHER WAY MADE USE OF, EXCEPT WITH THE PRIOR APPROVAL OF AKER YARDS S.A

    3.3 Dcoupure Type 3Cutout type 3

    h, b et s dfinis par AC ouHLPh, b and s defined by AC orHLP

    A-A

    3.4 Dcoupure Type 4Cutout type 4

    R30R45

    AA

    pas de soudureno welding

    meuler aprs dcoupageto be carefully grinded

    Plaque dobturation ventuelle pourintgrit incendie ep 4 mm prise encompte par AC ou HLP

    Potential sealing plate for the fireintegrity th 4 mm taken into accountby AC or HLP

    b

    h

    s

    outsideoutside bulkhead

    polyester seal insidepas de soudureno welding

    b

    h

    s

    R80

  • Rf. : CM.6106.M2 Rev : 14NORMES DECONCEPTION

    DESIGNSTANDARD

    DECOUPURES DES PORTES ET BAIESDOORS AND PICTURE WINDOWS

    CUTOUTS Ce document comporte21 pagesPage

    13

    COPYRIGHT OF AKER YARDS S.A. ALL RIGHTS RESERVED.NO PART THEREOF MAY BE DISCLOSED, COPIED, DUPLICATED OR IN ANY OTHER WAY MADE USE OF, EXCEPT WITH THE PRIOR APPROVAL OF AKER YARDS S.A

    3.5 Dcoupure Type 5Cutout type 5

    Porte tanche extrieure tourniquet ou volantOutside watertight door with snib or with wheel

    r = 110 mm

    h, b et s dfinis par AC ou HLP h, b and s defined by AC or HLP

    3.6 Dcoupure Type 6Cutout type 6

    b

    h

    s

    r

    R30R45

    AA

    pas de soudureno welding

    meuler aprs dcoupageto be carefully grinded

    Plaque dobturation ventuelle pourintgrit incendie ep 4 mm prise encompte par AC ou HLP

    Potential sealing plate for the fireintegrity th 4 mm taken into accountby AC or HLP

    outsideoutside bulkhead

    polyester seal insidepas de soudureno welding

    b

    h

    R6010

    15

    40

    20

    rfrence largeur dcoupurereference cutout width

  • Rf. : CM.6106.M2 Rev : 14NORMES DECONCEPTION

    DESIGNSTANDARD

    DECOUPURES DES PORTES ET BAIESDOORS AND PICTURE WINDOWS

    CUTOUTS Ce document comporte21 pagesPage

    14

    COPYRIGHT OF AKER YARDS S.A. ALL RIGHTS RESERVED.NO PART THEREOF MAY BE DISCLOSED, COPIED, DUPLICATED OR IN ANY OTHER WAY MADE USE OF, EXCEPT WITH THE PRIOR APPROVAL OF AKER YARDS S.A

    3.7 Dcoupure Type 7Cutout Type 7

    SOUDURE INTERDITE(Sur le bord libre et 50 mm autourdes rayons).NO WELDING(On the free edge and 50 mmaround radius)

    Dans les zones hachures, le bordlibre de la tle sera meulsoigneusement.

    In the hatched areas, the freeedge of the plate will be groundedcarefully.

    H et L dfinies par HLP ou AC.

    H and L defined by HLP or AC.

    Dlardages : voirles dtails 1, 2, 3page 16

  • Rf. : CM.6106.M2 Rev : 14NORMES DECONCEPTION

    DESIGNSTANDARD

    DECOUPURES DES PORTES ET BAIESDOORS AND PICTURE WINDOWS

    CUTOUTS Ce document comporte21 pagesPage

    15

    COPYRIGHT OF AKER YARDS S.A. ALL RIGHTS RESERVED.NO PART THEREOF MAY BE DISCLOSED, COPIED, DUPLICATED OR IN ANY OTHER WAY MADE USE OF, EXCEPT WITH THE PRIOR APPROVAL OF AKER YARDS S.A

    3.8 Dcoupure Type 8Cutout Type 8

    Dans les zones hachures, le bordlibre de la tle sera meulsoigneusement.

    In the hatched areas, the freeedge of the plate will be groundedcarefully.

    SOUDURE INTERDITE(Sur le bord libre et 50 mm autourdes rayons).NO WELDING(On the free edge and 50 mmaround radius)

    H, L et S dfinies par HLP ou AC.

    H, L and S defined by HLP or AC.

    Dlardages : voirles dtails 1, 2, 3page 16

  • Rf. : CM.6106.M2 Rev : 14NORMES DECONCEPTION

    DESIGNSTANDARD

    DECOUPURES DES PORTES ET BAIESDOORS AND PICTURE WINDOWS

    CUTOUTS Ce document comporte21 pagesPage

    16

    COPYRIGHT OF AKER YARDS S.A. ALL RIGHTS RESERVED.NO PART THEREOF MAY BE DISCLOSED, COPIED, DUPLICATED OR IN ANY OTHER WAY MADE USE OF, EXCEPT WITH THE PRIOR APPROVAL OF AKER YARDS S.A

    E1

    aep

    Cloison suprieure

    E2

    Cloison infrieure

    pont

    0 < < 3mm

    CCAASS 11 :: rriieenn

    Chanfrein 45 avec talon E1

    CCAASS 22 :: cchhaannffrreeiinn 4455

    4mm < < 5mm

    ep

    E1

    E2

    a

    E1

    E2

    ep4 x

    a

    CCAASS 33 :: ddllaarrddaaggee ssttaannddaarrdd

    > 5mm

    dlardage standard

    3.9 Dtails des dlardages sur les inserts de portes type 7 et type 8 Details of taperings on the inserts of doors type 7 et type 8

    = Ecart entre les paisseurs E1 et E2

  • Rf. : CM.6106.M2 Rev : 14NORMES DECONCEPTION

    DESIGNSTANDARD

    DECOUPURES DES PORTES ET BAIESDOORS AND PICTURE WINDOWS

    CUTOUTS Ce document comporte21 pagesPage

    17

    COPYRIGHT OF AKER YARDS S.A. ALL RIGHTS RESERVED.NO PART THEREOF MAY BE DISCLOSED, COPIED, DUPLICATED OR IN ANY OTHER WAY MADE USE OF, EXCEPT WITH THE PRIOR APPROVAL OF AKER YARDS S.A

    Points de vigilance pour les portes type 7 et type 8 :

    => Vrifier la conformit des gorges et type de soudure avec celles demandes par le groupe calcul

    => Vrifier les dlardages/chanfreins des inserts de porte :

    - Faire des coupes sous TRIBON pour chaque chanfrein/dlardage

    - Vrifier les panels

    - Vrifier sur les 088 les indications de chanfreins

    Rmq :La ralisation d un dlardage cote jusqu une journe l usinage,Une erreur de description (ex dlardage du mauvais cot) peut engendrer plus de 100h de rparation

    Points of vigilance for the doors type 7 and type 8:

    To verify the conformity of the throats and type ofwelding with those asked by the group calculation

    To verify the taperings/bevelled edges of the door inserts:

    - To make some details under TRIBON for every bevelled edge/tapering

    - To verify the panels

    - To verify on the 088 the indications of bevelled edges

    Rmq:The realization of a tapering costs until one day to the cutting,A mistake of description (ex tapering on the bad side of the plate) can generate more than 100h of repair

  • Rf. : CM.6106.M2 Rev : 14NORMES DECONCEPTION

    DESIGNSTANDARD

    DECOUPURES DES PORTES ET BAIESDOORS AND PICTURE WINDOWS

    CUTOUTS Ce document comporte21 pagesPage

    18

    COPYRIGHT OF AKER YARDS S.A. ALL RIGHTS RESERVED.NO PART THEREOF MAY BE DISCLOSED, COPIED, DUPLICATED OR IN ANY OTHER WAY MADE USE OF, EXCEPT WITH THE PRIOR APPROVAL OF AKER YARDS S.A

    4. INTEGRATION DES DECOUPURESCUTOUTS INTEGRATION

    4.1 Cloison transversale de structureTransverse structural bulkhead

    4.2 Cloison longitudinale de structure et cloison plane demmnagementLongitudinal structural bulkhead and accomodation plane bulkhead

    E1

    E1

    XX

    X

    (r)

    = (r)

    X=200 mini pour une porte, X=150 mini pourune baie.Si X > 280 et X > 35 E1, prvoir unraidissage additionnel ( r ) 200 mini de ladcoupure de porte, 150 mini dunedcoupure de baie.- Porte type 1, 3, 4, 5 ou 6 : ( r ) plat de 80x8- Porte type 7 ou 8 : ( r ) plat de 100x10 si E1 < 16 ( r ) plat de 100x15 si 16 < E1 < 30X=200 mini for a door, X=150 mini for anopening.If X > 280 and X > 35 E1, forecast anadditional stiffening ( r ) 200 mini from adoor, 150 mini from an opening.- Door type 1, 3, 4, 5 or 6 : ( r ) flat 80x8- Door type 7 or 8 : ( r ) flat 100x10 if E1 < 16 ( r ) flat 100x15 if 16 < E1 < 30

    X

    X

    (r)X

    X, (r), voir 4.1 X, (r), see 4.1

  • Rf. : CM.6106.M2 Rev : 14NORMES DECONCEPTION

    DESIGNSTANDARD

    DECOUPURES DES PORTES ET BAIESDOORS AND PICTURE WINDOWS

    CUTOUTS Ce document comporte21 pagesPage

    19

    COPYRIGHT OF AKER YARDS S.A. ALL RIGHTS RESERVED.NO PART THEREOF MAY BE DISCLOSED, COPIED, DUPLICATED OR IN ANY OTHER WAY MADE USE OF, EXCEPT WITH THE PRIOR APPROVAL OF AKER YARDS S.A

    4.3 Cas particulierParticular case

    4.3.1 Proximit dun montant renforc ou dune cloisonNearness of a strengthened stanchion or a bulkhead

    Pas de point mouNo soft point

    100maxi

    Portetype 1

    Portetype 1

  • Rf. : CM.6106.M2 Rev : 14NORMES DECONCEPTION

    DESIGNSTANDARD

    DECOUPURES DES PORTES ET BAIESDOORS AND PICTURE WINDOWS

    CUTOUTS Ce document comporte21 pagesPage

    20

    COPYRIGHT OF AKER YARDS S.A. ALL RIGHTS RESERVED.NO PART THEREOF MAY BE DISCLOSED, COPIED, DUPLICATED OR IN ANY OTHER WAY MADE USE OF, EXCEPT WITH THE PRIOR APPROVAL OF AKER YARDS S.A

    4.3.2 Dcoupe renforce de type 2Strengthened cutting of type 2

    Domaine dapplication / Scope of application : - Portes extrieures Outside doors - Portes coulissantes Sliding doors

    - Portes de substitution pour des portes type 7 lorsquil y a une impossibilit technique de ralisation.

    Doors of substitution for doors type 7 when where is a technical impossibility of realization

    Fig 1 Exemple de dtail pour porte extrieure ou coulissante Example of detail for outside door or sliding door

    Dtail soudure

    e3

    **R 100

    Lmini

    Soudurevoir dtail

    e2

    e1

    B30

    Lmini > 2B + 100

    * : Interdiction absolue de souder lentourage de porte dans langle * ( 50 mm )* : Absolute interdiction to weld the setting of door in the angle * ( 50 mm )

  • Rf. : CM.6106.M2 Rev : 14NORMES DECONCEPTION

    DESIGNSTANDARD

    DECOUPURES DES PORTES ET BAIESDOORS AND PICTURE WINDOWS

    CUTOUTS Ce document comporte21 pagesPage

    21

    COPYRIGHT OF AKER YARDS S.A. ALL RIGHTS RESERVED.NO PART THEREOF MAY BE DISCLOSED, COPIED, DUPLICATED OR IN ANY OTHER WAY MADE USE OF, EXCEPT WITH THE PRIOR APPROVAL OF AKER YARDS S.A

    4.3.3 Cloison nervureRibbed bulkhead

    5

    150 mini

    15

    80x8150

    R80

    Les portes type 2 ont t cres principalement pour grer des sollicitations du bandeau sous unecontrainte densemble ou une flexion secondaire donc, le cas dutilisation le plus courant doit reprsenterune semelle horizontale prioritaire ce qui permet notamment daugmenter lpaisseur du bandeau quisera le plus souvent dcoup.

    Lorsque lpaisseur de la cloison est renforce localement sur tout lentrepont, on vite videmmentlinsert avec un rayon.

    Remarque :Ces portes sont utilises dans le cadre de la substitution la porte type 7 si :

    - Ces portes sont situes dans une brche ( ex : roulage cabines )- Ces portes sont trop proches dune structure perpendiculaire la structure porteuse de la porte.

    (Non-respect de la rgle des 200 mm pour le plat de bordure)Voir avec le responsable des portes.

    - Le calcul ICE a une exigence pour ces portes.

    The doors type 2 has been created mainly to manage solicitations of the upper plate therefore under ageneral constraint or a secondary bending, the most current use case must represent an horizontal flangewith priority what permits to increase the thickness of the upper plate that will be the more often cutnotably.

    When the thickness of the bulkhead is reinforced locally on all the steerage, one evidently avoids theinsert with a radius.

    Remark:These doors are used in the setting of the substitution in the door type 7 if:

    - These doors are situated in a breach (ex: haulage cabins)- These doors are too near of a perpendicular structure to the structure bearer of the door. (Failure torespect of the rule of the 200 mm for the stiffener of border)To see with the person responsible of the doors.- The ICE calculation has a requirement for these doors.