Cluster Configuation for EMS and POMC Integrated (HP DL380+HP Disk Array+WIN2003+SQL2005)

Embed Size (px)

Citation preview

  • 7/31/2019 Cluster Configuation for EMS and POMC Integrated (HP DL380+HP Disk Array+WIN2003+SQL2005)

    1/108

    Chapter 1 Introduction to Dual-ComputerCluster Installation and Configuration

    1.1 Cluster Installation Flow

    A. Configure RAID mode for disk array.

    B. Install operating system and its patches.

    1. Configure operating system parameters.

    2. Set dual-NIC teaming

    C. Install domain controller

    D. Install Windows cluster service

    E. Install SQL Server 2005

    F. Install SQL2005 Server patches

    G. Install network management system

    1.2 Scene of Dual-Computer Cluster and Planning

    The scene is as follows, where OMCR and OMCS share the SQL on the disk array and the SQL uses dual-instance.

    1. In normal working state, one machine runs OMCS and the other runsOMCR. The equipment is in the following state.

    1

  • 7/31/2019 Cluster Configuation for EMS and POMC Integrated (HP DL380+HP Disk Array+WIN2003+SQL2005)

    2/108

    2. Switchover takes place once a server fails, one machine runs both OMCRand OMCS, as shown in the figure below.

    According to the scene above, resources may be allocated as follows.

    Disk array: consists of at least 6 hard disks.

    2 disks as CLUSTER arbitration disks, RAID1 mode, disk name: M

    2 disks for wireless side network management system and database

    instances, RAID1 mode, (more disks will be better if permitted, and RAID

    mode may also alter according to the quantity of disks), disk name: Q

  • 7/31/2019 Cluster Configuation for EMS and POMC Integrated (HP DL380+HP Disk Array+WIN2003+SQL2005)

    3/108

    2 disks for core network side network management system and

    database instances, RAID1 mode, (more disks will be better if permitted,

    and RAID mode may also alter according to the quantity of disks), disk

    name: N

    Windows CLUSTER: 2 cluster groups: Group0 and Group1.

    Group0: Add resources Disk Q, SQL2005 default instance SQLDB1, and

    POMC network management application to this group, as shown in the

    figure below.

    Group1: Add resources Disk N, SQL2005 default instance SQLDB2, and

    EMS network management application to this group, as shown in the figure

    below.

  • 7/31/2019 Cluster Configuation for EMS and POMC Integrated (HP DL380+HP Disk Array+WIN2003+SQL2005)

    4/108

    Version of core network EMS: EMS10.10.40.P4.B3b

    Version of wireless side POMC: V3.08.19.01_OMCR_ZXC10-BSSB

    Operations on server:

    Machine A (SERVER1): Install SQL2005 default instance and wireless side

    network management system POMC onto Disk Q.

    Machine B (SERVER2): Install SQL2005 instance 2 and core-network

    network management system EMS onto Disk N.

    1.3 Activate Keys of HP DL380 G3

    F8 Lights-out Press Configuration

  • 7/31/2019 Cluster Configuation for EMS and POMC Integrated (HP DL380+HP Disk Array+WIN2003+SQL2005)

    5/108

    F8 Disk Array Configuration (configuring RAID mode)

    F9 Enter BIOS settings

    F10 Enter system maintenance menu

    F12 Boot up from network (PXE Boot)

    1.4 RAID Mode

    The default disk setting of the system is as follows.

    In case of 2 disks, one disk is the mirror of the other, that is, they are configured in RAID1 mode. In case

    of more disks, the disks are configured in RAID5 mode. Fore example, in case of 5 disks, the RAID5

    mode configuration is: the final available disk space is the size of four disks, and the fifth disk saves

    check data with which the disk data may be restored if the data on one of the four disks are damaged.

    In case of 2 disks, RAID1 is required. Since the default RAID mode for two disks is RAID1, it is of no

    need to set it again, but a check on the RAID mode is necessary.

    Common Disk Array Deployment

    A disk array generally consists of more than 2 disks and must be configured by entering the

    configuration menu. Refer to relevant specifications for the relation between quantity of disks and RAIDmode.

    Note: Planning on quantity of disks should be made before disk array installation. It is

    recommended to configure at least 6 disks: 2 disks as CLUSTER arbitration disks in

    RAID1 mode, other 2 disks for wireless side network management system and database

    instances, in RAID1 mode (more disks will be better if permitted, and RAID mode may

    also alter according to the quantity of disks), and the other 2 disks for core network side

    network management system and database instances, in RAID1 mode (more disks will be

    better if permitted, and RAID mode may also alter according to the quantity of disks).

    Refer to 2.1 for details about disk array configuration.

    1.5 Domain Controller

    The two computers should be installed as domain controller, and cluster software need be installed

    on them after domain update.

  • 7/31/2019 Cluster Configuation for EMS and POMC Integrated (HP DL380+HP Disk Array+WIN2003+SQL2005)

    6/108

  • 7/31/2019 Cluster Configuation for EMS and POMC Integrated (HP DL380+HP Disk Array+WIN2003+SQL2005)

    7/108

    Chapter 2 Installation of Operating System2.1 Setting Disk Array

    1. Power on the disk array.

    2. Shut down Machine B and power on Machine A. And boot up the machine from CD through HP

    SmartStart.

    3. At the first bootup interface of SmartStart 7.0, select language English and keyboard type English

    and then click button Continue.

    4. Select Agreeat PROLIANT End User License Agreement interface.

    5. Open Maintenance tab when SmartStart starts and click launch array configuration utility

    (ACU).

    6. Select the corresponding array controller.

    7. Select all disks and click OK to create array. (Depending on the situation, select two disks

    respectively if it is in 2+2+2 mode.)

  • 7/31/2019 Cluster Configuation for EMS and POMC Integrated (HP DL380+HP Disk Array+WIN2003+SQL2005)

    8/108

    8. Create logical drive, select RAID mode (fault tolerance) and default setting may be used for

    other items.

    3 logic disks now appear in disk manager. ClickSave.

    9. Power on machine B to install on it.

    2.2 Installing Operating System

    It is recommended to use the SmartStart CD attached with HP server to install the operating system.

    The SmartStart CD may copy all system-related drivers onto the server and automatically install the

    hardware drivers, for example NIC driver and dual-NIC teaming program, after the operating system

  • 7/31/2019 Cluster Configuation for EMS and POMC Integrated (HP DL380+HP Disk Array+WIN2003+SQL2005)

    9/108

    is installed, which greatly simplifies the installation.

    In case of dual-computer cluster with a disk array, Machine B must be shut down before installing the

    cluster software such as MSCS, to ensure that the installation of cluster begins after Machine A takes

    over the disk array. And after the installation of cluster on Machine A, Machine A must keep running

    so that Machine B may detect the cluster created on Machine A when cluster is being installed on

    Machine B.

    Now, operating system may be installed on Machine A and Machine B at the same time.

    1. Insert SmartStart Release 7.10 CD into the drive and start the machine, the system will boot up

    from the SmartStart CD.

    If the CDROM is not the first bootup disk, press F9 to enter BIOS settings and set CDROM as the

    first bootup disk (CDROM is the first bootup disk by default.)

    2. Configure OS installation parameters at the Internet Explorer interface.

    a) Select setup page and configure installation information.

    b) Select prompt language English.

    c) Select OS Windows 2003 Advance Server.

    d) Set license type to 100 clients per server.

    e) Set file system to NTFS, and size of primary partition C to 20,000MB. And select formatting

    primary partition (partition C) only when a dialog box prompting for format appears.

    f) Keep the default SNMP setting.

    3. After OS parameters configuration, insert Win2003 AS installation CD when the Smart CD ejects

    automatically. The installation process begins copying files.

    4. When OS files are copied, the Win2003 AS installation CD ejects automatically while the OS

    installation proceeds. Time zone, work group and computer name need be configured during this

    process. Input according to the installation specifications of each server.

    Note: Input WORKGROUP for servers which are configured as domain controller. Configure

    domain name when installing domain controller after the installation of OS.

    5. Wait some time for the HP drivers to configure the system after OS installation.

  • 7/31/2019 Cluster Configuation for EMS and POMC Integrated (HP DL380+HP Disk Array+WIN2003+SQL2005)

    10/108

    2.3 Installing WIN2003 SP2

    WIN2003 SP2 is required for installing SQL2005 and need be installed on both Machine A and

    Machine B.

    Select No when the dialog box prompting for whether overwrite existing filesappears during the

    installation.

    2.4 OS Settings

    Note: Operations above may be made on Machine A and Machine B at the same time. As for the

    operations below, start the disk array first, then start Machine A with Machine B shut down to

    configure OS settings, and then shut down Machine A and start Machine B and configure the same

    settings on Machine B.

    2.4.1 Partitioning Disk

    Set drive letters, allocate and format remaining hard disk space.

    Step 1: Right-lick My Computer and select Management to open the Computer Management

    window, and change CDROM drive letterD into E in Disk Management.

    Step 2: Allocate local remaining disk space and set drive letter to D, and perform fast format (NTFS).

    Step 3: Degrade the array signature to normal disk if there is a disk array, and set the drive letter to M

    and perform fast format.

    2.4.2 Setting Size of System Log

    Right-lick My Computer and select Management to open the Computer Management window.

    Right-click Application underEvent Viewer and select Properties, and set maximum log size to

    4096KB and Overwrite Event Older than to 1 day.

    Right-lick My Computer and select Management to open the Computer Management window.

    Right-click Security under Event Viewer and select Properties, and set maximum log size to

    4096KB and Overwrite Event Older than to 1 day.

    Right-lick My Computer and select Management to open the Computer Management window.

    Right-clickSystem underEvent Viewer and select Properties, and set maximum log size to 4096KB

    and Overwrite Event Older than to 1 day.

  • 7/31/2019 Cluster Configuation for EMS and POMC Integrated (HP DL380+HP Disk Array+WIN2003+SQL2005)

    11/108

    2.4.3 Setting System Virtual Memory

    Right-lickMy Computer and select Management to open the System Properties window. Select

    Advanced tab and click performance Settings button to open the Performance Options window. Set

    minimum virtual memory to 1.5 times of system memory and maximum virtual memory to 3 times of

    system memory.

  • 7/31/2019 Cluster Configuation for EMS and POMC Integrated (HP DL380+HP Disk Array+WIN2003+SQL2005)

    12/108

  • 7/31/2019 Cluster Configuation for EMS and POMC Integrated (HP DL380+HP Disk Array+WIN2003+SQL2005)

    13/108

    CheckFault Tolerant and keep default settings for other options, and change team name to Public for

    purpose of ease of management.

    3. Open network connection properties after NIC teaming, and a new connection should be there, as

    connection 4 in the figure below.

  • 7/31/2019 Cluster Configuation for EMS and POMC Integrated (HP DL380+HP Disk Array+WIN2003+SQL2005)

    14/108

    Right-click it and select Properties to set the IP address, as shown in the figure below. It is

    unnecessary to configure gateway, and the preferred DNS is set to the IP address of the preferred domain

    controller. If the domain controller is installed on Machine A, then enter the IP address of Machine A.

  • 7/31/2019 Cluster Configuation for EMS and POMC Integrated (HP DL380+HP Disk Array+WIN2003+SQL2005)

    15/108

    4. Network configuration (for instance, one heart-beat cable by default)

    NIC IP address Subnet mask Preferred DNS Alternate DNS Remarks

    Machine-A

    heartbeat

    cable

    10.0.0.1 255.255.0.0 - - NetBIOS disabled, speed: 10M half-

    duplex

    Machine-B

    heartbeat

    cable

    10.0.0.2 255.255.0.0 - - NetBIOS disabled, speed: 10M half-

    duplex

    Machine-A

    team cable

    129.20.129.151 255.255.0.0 129.20.129.151 -

    Machine-B

    team cable

    129.20.129.152 255.255.0.0 129.20.129.151 -

  • 7/31/2019 Cluster Configuation for EMS and POMC Integrated (HP DL380+HP Disk Array+WIN2003+SQL2005)

    16/108

    3.2 Setting Heartbeat Cable

    Set heartbeat cable on both Machine A and Machine B.

    Two crossover network cables are used as heartbeat cables to connect NICs of two servers. Suppose the NICs

    used for heartbeat connection are Private1 and Private2. If only one NIC is used for heartbeat connection,

    there is one heartbeat cable and one Private.

    Set local heartbeat IP address:

    Heartbeat 1: Machine A: Heartbeat IP address of local connection: 10.0.0.1, subnet mask: 255.255.0.0, no

    default gateway, no DNS; Machine B: Heartbeat IP address of local connection: 10.0.0.2, subnet mask:

    255.255.0.0, no default gateway, DNS: 10.0.0.1

    Heartbeat 2: Machine A: Heartbeat IP address of local connection 2: 10.10.10.1, subnet mask: 255.255.255.0,

    no default gateway, no DNS; Machine B: Heartbeat IP address of local connection: 10.10.10.2, subnet mask:

    255.255.255.0, no default gateway, DNS: 10.10.10.1

    Open the network connection properties window as shown in the figure below, and check Internet Protocol

    (TCP/IP) and HP Network Configuration Utility and uncheck all the others.

    Open the TCP/IP configuration window as shown in the figure below. Set DNS of Machine A to null and

  • 7/31/2019 Cluster Configuation for EMS and POMC Integrated (HP DL380+HP Disk Array+WIN2003+SQL2005)

    17/108

    DNS of Machine B to the IP of Machine A..

    ClickAdvance, and select tab WINS, disable NetBIOS over TCP/IP.

  • 7/31/2019 Cluster Configuation for EMS and POMC Integrated (HP DL380+HP Disk Array+WIN2003+SQL2005)

    18/108

    Right-click the heartbeat connection, select Properties to open the configuration window. Click Advanced and

    set Speed & Duplex to 10Mbps/Half Duplex.

    Note: Pay attention to the sequence in advanced settings of network and dialup connection as shown in the

    figure below. Public (the virtual NIC after NIC teaming) should be the first, and do not set Private (heartbeat)

    to the first.

  • 7/31/2019 Cluster Configuation for EMS and POMC Integrated (HP DL380+HP Disk Array+WIN2003+SQL2005)

    19/108

  • 7/31/2019 Cluster Configuation for EMS and POMC Integrated (HP DL380+HP Disk Array+WIN2003+SQL2005)

    20/108

    Chapter 4 Installation of Domain Controllerand Cluster

    4.1 Installing Domain Controller

    Configure the IP address and heartbeat IP address of each cluster node or the IP address of a single-

    machine TEAM. Set the DNS with the preferred DNS directing to its own IP.

    Create a new domain and DNS server on Machine A, and then configure the additional domain controller on

    Machine B. Pay attention to the operation sequence. It is very complicated to roll back the operations in caseof repeated domain creation or wrong operation.

    4.1.1 Creating Domain Controller for a new Domain

    The operations to create domain controller for a new domain are as follows, which need

    be performed on Machine A only.

    1. Select Start-> Administrative Tools->Configure Your Server Wizard to open

    the window as shown in Figure 4.1-1.

    Figure 4.1-1 Configure Server

    2. ClickNext. The Wizard searches for network connections, and then the window

    as shown in Figure 4.1-2 appears.

  • 7/31/2019 Cluster Configuation for EMS and POMC Integrated (HP DL380+HP Disk Array+WIN2003+SQL2005)

    21/108

    Figure 4.1-2 Create Domain Controller for a New Domain

    3. CheckTypical configuration for a first server, clickNext, input new domain

    name (DNS full name of the new domain), as shown in the figure below. Input

    the domain name as shown in Figure 4.1-3.

    Figure 4.1-3 Naming the new domain

    4. ClickNext, keep the default NetBIOS domain name as shown in Figure 4.1-4.

  • 7/31/2019 Cluster Configuation for EMS and POMC Integrated (HP DL380+HP Disk Array+WIN2003+SQL2005)

    22/108

    Figure 4.1-4 Assigning NetBIOS domain name

    5. ClickNext. Select No when the prompt for forwarding DNS queries appears, as

    shown in Figure 4.1-5.

    Figure 4.1-5 Whether Forward Unresolved DNS Queries

    6. ClickNext. The Summary of Selections window appears as shown in Figure

    4.1-6.

  • 7/31/2019 Cluster Configuation for EMS and POMC Integrated (HP DL380+HP Disk Array+WIN2003+SQL2005)

    23/108

    Figure 4.1-6 Summary of Selections

    7. ClickNext to proceed. The wizard will ask to specify an existing interface for

    accessing Internet, as shown in Figure 4.1-7.

    Figure 4.1-7 Select Internet Access Interface

    8. ClickNext to proceed. The wizard will ask to insert the Windows 2003 Server

  • 7/31/2019 Cluster Configuation for EMS and POMC Integrated (HP DL380+HP Disk Array+WIN2003+SQL2005)

    24/108

    CD. Insert Windows 2003 Enterprise With SP1 CD or SP1 CD, as shown in

    Figure 4.1-8.

    Figure 4.1-8 Prompt for Inserting CD

    9. The wizard will automatically configure the DNS, the windows after

    configuration completed is as shown in Figure 4.1-9.

    Figure 4.1-9 Server Configuration Process

  • 7/31/2019 Cluster Configuation for EMS and POMC Integrated (HP DL380+HP Disk Array+WIN2003+SQL2005)

    25/108

    4.1.2 Creating Additional Domain Controller for an Existing Domain

    The operations to create additional domain controller for an existing domain are as

    follows, which need be performed on Machine B only.

    1. Enter Network Connections, select Local Area Connection Properties ->

    Internet Protocol (TCP/IP). Input IP address of the active server for preferred

    DNS server, that is, IP address of Machine A as for this instance.

    Note: Its better to set the preferred DNS server of Machine B heartbeat TCP/IP

    properties to the IP address of Machine A heartbeat NIC to avoid connection

    failures which may occur during the following steps.

    2. Restart Machine B after the settings above, and select Start->Administrative

    Tools-> Configure Your Server Wizard, and select Custom configuration, as

    shown in Figure 4.1-10.

    Figure 4.1-10 Set Domain Controller Type -1

  • 7/31/2019 Cluster Configuation for EMS and POMC Integrated (HP DL380+HP Disk Array+WIN2003+SQL2005)

    26/108

    3. ClickNext. Select server role Domain Controller, as shown in Figure 4.1-11.

    Figure 4.1-11 Set Domain Controller Type -2

    4. ClickNext. The Summary of Selections window appears as shown in Figure 4.1-

    12.

    Figure 4.1-12 Set Domain Controller Type -3

  • 7/31/2019 Cluster Configuation for EMS and POMC Integrated (HP DL380+HP Disk Array+WIN2003+SQL2005)

    27/108

    5. ClickNext to proceed. The window as shown in Figure 4.1-13 appears. Input

    user name, password, and domain to join in.

    Figure 4.1-13 Input Network User Name and Password

    6. ClickNext to open the window as shown in Figure 4.1-14. Input the full domain

    name.

    Figure 4.1-14 Setting Additional Domain Controller

    7. ClickNext to open the window as shown in Figure 4.1-15. Select or input the

  • 7/31/2019 Cluster Configuation for EMS and POMC Integrated (HP DL380+HP Disk Array+WIN2003+SQL2005)

    28/108

    paths of database and log files. The default settings may be adopted.

    Figure 4.1-15 Paths of Database and Log Files

    8. ClickNext to open the window as shown in Figure 4.1-16. Select or input the

    path of shared system volume. The default setting may be adopted.

    Figure 4.1-16 Shared System Volume

  • 7/31/2019 Cluster Configuation for EMS and POMC Integrated (HP DL380+HP Disk Array+WIN2003+SQL2005)

    29/108

    9. ClickNext to open the window as shown in Figure 4.1-17. Set the administrator

    password for directory services in restoration mode. The default setting is null.

    Figure 4.1-17 Administrator Password for Directory Services in Restoration Mode

    10. ClickNext and the Summary window appears as shown in Figure 4.1-18.

    Figure 4.1-18 Summary of Installation Wizard

  • 7/31/2019 Cluster Configuation for EMS and POMC Integrated (HP DL380+HP Disk Array+WIN2003+SQL2005)

    30/108

    4.1.3 Partitioning Shared Disk Array

    The partitioning of disk array shared in cluster mode is performed on either one

    server only. The following takes Machine A for example. As is described in

    section 2.1 Setting Disk Array the disk array are already partitioned into 3

    logical disks, so it just need to make the system identify the logical disks and

    rename them. They are to be named M, N and Q respectively, among which M

    is for arbitration and N and Q are for network management system and database

    instances respectively of Machine A and Machine B.

    Note:

    After creating two logical partitions and formatting them in NTFS format,

    assign shared data partition to N and arbitration partition to M so that the

    purpose of shared disk array space may be easily identified.

    The detailed operation is as follows.

    1. Open the Computer Management window.

    Ensure that the disk array and the connection between disk array and the

    server are normal. ClickStart -> Administrative Tools -> Computer

    Management to open the Computer Management window as shown in

    Figure 4.1-19.

    Figure 4.1-19 Computer Management

  • 7/31/2019 Cluster Configuation for EMS and POMC Integrated (HP DL380+HP Disk Array+WIN2003+SQL2005)

    31/108

    2. Initialize and convert disk

    (1) Select Storage -> Disk Management on the navigation tree in the

    window as shown in Figure 4.1-19. The window for initializing and

    converting disk appears if the computer connects a disk array and it is

    the first time to open the Disk Management window, as shown in Figure

    4.1-20.

    Figure 4.1-20 Initializing and Converting Disk

    (2) Click Next to proceed. Check Disk 0 in the window that appears, as

    shown in Figure 4.1-21.

    Figure 4.1-21 Select Disk to Be Initialized

  • 7/31/2019 Cluster Configuation for EMS and POMC Integrated (HP DL380+HP Disk Array+WIN2003+SQL2005)

    32/108

    (3) Click Next to proceed. Uncheck Disk 0 in the window that appears, as

    shown in Figure 4.1-22.

    Figure 4.1-22 Select Disk to Be Converted

    (4) Click Next to proceed.

    (5) Click Finish to complete disk initialization and conversion and return to

    the Computer Management window, where three logical disks are now

    available. Perform fast format in NTFS on them.

    Note:

    Because of the difference in RAID mode and quantity of disks the size of Disk

    0 may be different.

    Note:

    After the disk array configuration on one computer an alarm about SCSI may

    occur on the other computer when it starts. The alarm may disappear after the

    cluster software is installed (Refer to 4.2 Installing Cluster Software.), since the

    arbitration disk will then become invalid and simultaneous access to the disk

    array will be avoided.

    4.1.4 Partitioning Local Disks of Server

    The operation need be made on both Machine A and Machine B.

  • 7/31/2019 Cluster Configuation for EMS and POMC Integrated (HP DL380+HP Disk Array+WIN2003+SQL2005)

    33/108

    Open the Disk Management window and allocate partition size. Since Partition

    C is already created and formatted, just allocate the remaining disk space to

    Partition D and set CDROM to drive E. The file system of each partition is

    NTFS.

    4.2 Installing Cluster Software

    1. On Machine A, click Start -> Administrative Tools -> Cluster

    Administrator to open the cluster administrator and create a new

    cluster, as shown in Figure 4.2-23.

    Figure 4.2-23 Installing Cluster Components

    2. ClickOKto start the cluster configuration wizard, as shown in Figure

    4.2-24

  • 7/31/2019 Cluster Configuation for EMS and POMC Integrated (HP DL380+HP Disk Array+WIN2003+SQL2005)

    34/108

    Figure 4.2-24 Cluster Service Configuration Wizard (1)

    3. ClickNext to open the window as shown in Figure 4.2-25. Input cluster

    name and domain.

    Figure 4.2-25 Cluster Service Configuration Wizard (2)

    Note:

    The cluster name must not be the same as an existing server name in the

    network. Otherwise it may cause configuration failure or conflict.

  • 7/31/2019 Cluster Configuation for EMS and POMC Integrated (HP DL380+HP Disk Array+WIN2003+SQL2005)

    35/108

    4. Configure cluster node and select the first node, as shown in Figure 4.2-

    26.

    Figure 4.2-26 Configure Cluster Node

    5. ClickNext, and the wizard will analyze the configuration information.

    And then configure cluster IP, which should be within a same network

    section with the teamed virtual NIC, for example 129.20.129.154, as

    shown in Figure 4.2-27.

    Figure 4.2-27 Configure Cluster IP

  • 7/31/2019 Cluster Configuation for EMS and POMC Integrated (HP DL380+HP Disk Array+WIN2003+SQL2005)

    36/108

    6. Click Next to proceed. The domain account configuration window

    appears. Input domain user name and domain name, as shown in Figure

    4.2-28.

    Figure 4.2-28 Specify Domain Count Using Cluster

    7. Click Next, and the cluster configuration is displayed, as shown in

    Figure 4.2-29.

    Figure 4.2-29 Cluster Configuration Information

  • 7/31/2019 Cluster Configuation for EMS and POMC Integrated (HP DL380+HP Disk Array+WIN2003+SQL2005)

    37/108

    8. ClickNext to create the cluster, as shown in Figure 4.2-30.

    Figure 4.2-30 Cluster Arbitration Disk Configuration

    9. Keep the active domain controller (Machine A) running, and log onto

    the additional domain controller (Machine B).

    10. On Machine B, clickStart-> Administrative Tools->Cluster Manager

    to open the cluster manager and open the connection to the cluster, as

    shown in Figure.

    Figure 4.2-31 Connection to Cluster

  • 7/31/2019 Cluster Configuation for EMS and POMC Integrated (HP DL380+HP Disk Array+WIN2003+SQL2005)

    38/108

    11. ClickOKto open the connection to the cluster, and clickNext to open

    the window as shown in Figure 4.2-32. Input the computer to be added.

    Figure 4.2-32 Input Computer to Be Added

    12. Click Next to proceed. The cluster service may start up successfully

    after the configuration.

    4.3 Configuring MSCS

    Run the Cluster Administrator after the cluster is installed, and the two servers should be mounted in

    the cluster. Cluster Group is the default cluster group, and Cluster IP Address is the IP address

    entered during cluster installation. Add arbitration disk M to the Cluster Group, as shown in the

    figure below.

  • 7/31/2019 Cluster Configuation for EMS and POMC Integrated (HP DL380+HP Disk Array+WIN2003+SQL2005)

    39/108

    Add another two groups: Group0 and Group1. And add Disk Q and Disk N as physical disk

    resources to the two groups respectively, as shown in the figure below.

    The procedure to add a physical disk resource is as follows.

  • 7/31/2019 Cluster Configuation for EMS and POMC Integrated (HP DL380+HP Disk Array+WIN2003+SQL2005)

    40/108

    Input disk name, select resource type Physical Disk, and select the group which the disk is to be

    added to.

  • 7/31/2019 Cluster Configuation for EMS and POMC Integrated (HP DL380+HP Disk Array+WIN2003+SQL2005)

    41/108

    Add the servers that may use this disk and clickNext.

    Configure the dependency (optional), and clickNext.

  • 7/31/2019 Cluster Configuation for EMS and POMC Integrated (HP DL380+HP Disk Array+WIN2003+SQL2005)

    42/108

    Select the disk to be added, for example Q, and clickFinish to complete the adding of disk resource.

    The result is as follows.

  • 7/31/2019 Cluster Configuation for EMS and POMC Integrated (HP DL380+HP Disk Array+WIN2003+SQL2005)

    43/108

    Now the task to be done is to install SQL2005 on the two servers.

  • 7/31/2019 Cluster Configuation for EMS and POMC Integrated (HP DL380+HP Disk Array+WIN2003+SQL2005)

    44/108

    Chapter 5 Installation of SQL2005

    5.1 Installing SQL2005 SE

    Run Setup.exe in folder Servers of SQL2005 CD (or folder CD1, or on the first CD), the end

    user license agreement appears.

    Accept the terms and clickNext. The Installing Prerequisites window appears.

  • 7/31/2019 Cluster Configuation for EMS and POMC Integrated (HP DL380+HP Disk Array+WIN2003+SQL2005)

    45/108

    ClickInstall to start installation.

  • 7/31/2019 Cluster Configuation for EMS and POMC Integrated (HP DL380+HP Disk Array+WIN2003+SQL2005)

    46/108

    Wait the required components to be installed.

  • 7/31/2019 Cluster Configuation for EMS and POMC Integrated (HP DL380+HP Disk Array+WIN2003+SQL2005)

    47/108

  • 7/31/2019 Cluster Configuation for EMS and POMC Integrated (HP DL380+HP Disk Array+WIN2003+SQL2005)

    48/108

    ClickNext. The system configuration check window appears.

  • 7/31/2019 Cluster Configuation for EMS and POMC Integrated (HP DL380+HP Disk Array+WIN2003+SQL2005)

    49/108

    Warning messages concerning IIS may be ignored since the SQL2005 components to be

    installed do not use IIS functions. Click Next to proceed.

  • 7/31/2019 Cluster Configuation for EMS and POMC Integrated (HP DL380+HP Disk Array+WIN2003+SQL2005)

    50/108

    The registration information appears.

  • 7/31/2019 Cluster Configuation for EMS and POMC Integrated (HP DL380+HP Disk Array+WIN2003+SQL2005)

    51/108

    Input registration information and click Next. The window showing the components to be

    installed appears.

  • 7/31/2019 Cluster Configuation for EMS and POMC Integrated (HP DL380+HP Disk Array+WIN2003+SQL2005)

    52/108

    Select as is shown in the figure above, and click Advanced to open the Feature Selection

    window.

  • 7/31/2019 Cluster Configuation for EMS and POMC Integrated (HP DL380+HP Disk Array+WIN2003+SQL2005)

    53/108

    Select Database Services, and clickBrowse to change installation path.

    The installation path of Data Files of database services should be on Disk Q of the disk

    array (It is Disk N when SQL2005 is installed on Machine B). Other installation paths may be

    on the local disk.

  • 7/31/2019 Cluster Configuation for EMS and POMC Integrated (HP DL380+HP Disk Array+WIN2003+SQL2005)

    54/108

    Do not select item Full-Text Search under Database Services. Change the installation path of

    Shared Tools to Disk D. Analysis Servers are also required. The installation path of Data Files

    of analysis services should be on Disk Q of the disk array (It is Disk N when SQL2005 is

    installed on Machine B).

  • 7/31/2019 Cluster Configuation for EMS and POMC Integrated (HP DL380+HP Disk Array+WIN2003+SQL2005)

    55/108

    Change the installation path of client components to Disk D. Select client components as

    shown in the figure below.

  • 7/31/2019 Cluster Configuation for EMS and POMC Integrated (HP DL380+HP Disk Array+WIN2003+SQL2005)

    56/108

    ClickNext. The Instance Name window appears. (Select the default instance on Machine A.

    Select the second instance and add an instance name, such as: SQLDB2.)

  • 7/31/2019 Cluster Configuation for EMS and POMC Integrated (HP DL380+HP Disk Array+WIN2003+SQL2005)

    57/108

    Select default instance and clickNext.

  • 7/31/2019 Cluster Configuation for EMS and POMC Integrated (HP DL380+HP Disk Array+WIN2003+SQL2005)

    58/108

    Click OK. The Virtual Server Name window appears. Input virtual server name, such as

    SQLDB1.

  • 7/31/2019 Cluster Configuation for EMS and POMC Integrated (HP DL380+HP Disk Array+WIN2003+SQL2005)

    59/108

    Click Next. The Virtual Server Configuration window appears. Select the virtual NIC with

    dual-NIC teamed, which may access the outer network. Set the IP address, which should be in a

    same network section with the virtual NIC, such as 129.20.129.155. For Machine B, the IP address

    is 129.20.129.156.

  • 7/31/2019 Cluster Configuation for EMS and POMC Integrated (HP DL380+HP Disk Array+WIN2003+SQL2005)

    60/108

    ClickAdd, and the result is as shown in the figure below.

  • 7/31/2019 Cluster Configuation for EMS and POMC Integrated (HP DL380+HP Disk Array+WIN2003+SQL2005)

    61/108

    ClickNext. The following window appears. Select group, for example Group0, and set the path

    of data files to Q:\Microsoft SQL Server\. (For installation on Machine B, select Group1, and set the

    path of data files to N:\Microsoft SQL Server\.) Note: Do not select the default Cluster Group which

    contains arbitration disk M.

  • 7/31/2019 Cluster Configuation for EMS and POMC Integrated (HP DL380+HP Disk Array+WIN2003+SQL2005)

    62/108

    ClickNext, and the window as shown in the figure below appears. Select corresponding server

    node. Add the node name of Machine A in case of default instance on Machine A, for example ems1,

    or add the node name of Machine B in case of the second instance on Machine B, for example ems2.

  • 7/31/2019 Cluster Configuation for EMS and POMC Integrated (HP DL380+HP Disk Array+WIN2003+SQL2005)

    63/108

    Click Next, and the window as shown in the figure below appears. Input the password for

    Administrator.

  • 7/31/2019 Cluster Configuation for EMS and POMC Integrated (HP DL380+HP Disk Array+WIN2003+SQL2005)

    64/108

    Click Next, and the window as shown in the figure below appears. Input user name

    Administrator and password, and enter the domain name.

  • 7/31/2019 Cluster Configuation for EMS and POMC Integrated (HP DL380+HP Disk Array+WIN2003+SQL2005)

    65/108

    ClickNext, and the window as shown in the figure below appears.

  • 7/31/2019 Cluster Configuation for EMS and POMC Integrated (HP DL380+HP Disk Array+WIN2003+SQL2005)

    66/108

    ClickNext, and the window as shown in the figure below appears. Select Mixed Mode, and set

    the logon password for the database instance (a strong password may be required.)

  • 7/31/2019 Cluster Configuation for EMS and POMC Integrated (HP DL380+HP Disk Array+WIN2003+SQL2005)

    67/108

    ClickNext, and the window as shown in the figure below appears. Configure as is shown in the

    figure.

  • 7/31/2019 Cluster Configuation for EMS and POMC Integrated (HP DL380+HP Disk Array+WIN2003+SQL2005)

    68/108

    ClickNext, and the window as shown in the figure below appears. Configure as is shown in the

    figure.

  • 7/31/2019 Cluster Configuation for EMS and POMC Integrated (HP DL380+HP Disk Array+WIN2003+SQL2005)

    69/108

    ClickNext, and the window as shown in the figure below appears.

  • 7/31/2019 Cluster Configuation for EMS and POMC Integrated (HP DL380+HP Disk Array+WIN2003+SQL2005)

    70/108

    ClickInstall, installation starts (it may take some time).

  • 7/31/2019 Cluster Configuation for EMS and POMC Integrated (HP DL380+HP Disk Array+WIN2003+SQL2005)

    71/108

    Input CD2 as required and clickOKto continue, as shown in the figure below.

  • 7/31/2019 Cluster Configuation for EMS and POMC Integrated (HP DL380+HP Disk Array+WIN2003+SQL2005)

    72/108

    ClickNext to continue when the components are installed.

  • 7/31/2019 Cluster Configuation for EMS and POMC Integrated (HP DL380+HP Disk Array+WIN2003+SQL2005)

    73/108

    ClickFinish to complete.

  • 7/31/2019 Cluster Configuation for EMS and POMC Integrated (HP DL380+HP Disk Array+WIN2003+SQL2005)

    74/108

    Now the server need be rebooted. Open the Cluster Administrator on Machine when it is

    rebooted, and a successful installation result is as follows.

  • 7/31/2019 Cluster Configuation for EMS and POMC Integrated (HP DL380+HP Disk Array+WIN2003+SQL2005)

    75/108

    Refer to the operations above to install the second instance on Machine B. Note that correct

    cluster group and server node should be select. And a successful installation result is as follows.

    5.2 Installing SQL2005 SE SP2

    Download SQL SERVER 2005 SP2 from Microsoft Website:

    http://www.microsoft.com/downloads/details.aspx?FamilyID=d07219b2-1e23-49c8-8f0c-

    63fa18f26d3a&DisplayLang=en

    Double-click it to run the setup program.

    http://www.microsoft.com/downloads/details.aspx?FamilyID=d07219b2-1e23-49c8-8f0c-63fa18f26d3a&DisplayLang=enhttp://www.microsoft.com/downloads/details.aspx?FamilyID=d07219b2-1e23-49c8-8f0c-63fa18f26d3a&DisplayLang=enhttp://www.microsoft.com/downloads/details.aspx?FamilyID=d07219b2-1e23-49c8-8f0c-63fa18f26d3a&DisplayLang=enhttp://www.microsoft.com/downloads/details.aspx?FamilyID=d07219b2-1e23-49c8-8f0c-63fa18f26d3a&DisplayLang=en
  • 7/31/2019 Cluster Configuation for EMS and POMC Integrated (HP DL380+HP Disk Array+WIN2003+SQL2005)

    76/108

    ClickNext to continue, and the License Terms window appears.

  • 7/31/2019 Cluster Configuation for EMS and POMC Integrated (HP DL380+HP Disk Array+WIN2003+SQL2005)

    77/108

    Select I accept the agreement, and Next, and the Feature Selection window appears.

  • 7/31/2019 Cluster Configuation for EMS and POMC Integrated (HP DL380+HP Disk Array+WIN2003+SQL2005)

    78/108

    ClickNext to continue, and the Authentication window appears.

  • 7/31/2019 Cluster Configuation for EMS and POMC Integrated (HP DL380+HP Disk Array+WIN2003+SQL2005)

    79/108

    Select Windows Authentication, clickNext to continue, and the Error and Usage Reporting

    Setting window appears.

  • 7/31/2019 Cluster Configuation for EMS and POMC Integrated (HP DL380+HP Disk Array+WIN2003+SQL2005)

    80/108

    ClickNext to continue, and the Running Processes window appears.

  • 7/31/2019 Cluster Configuation for EMS and POMC Integrated (HP DL380+HP Disk Array+WIN2003+SQL2005)

    81/108

    Just clickNext and do not have to end the processes, and the Ready to Install window appears.

  • 7/31/2019 Cluster Configuation for EMS and POMC Integrated (HP DL380+HP Disk Array+WIN2003+SQL2005)

    82/108

    ClickInstall to start installation. (It may take some time.)

  • 7/31/2019 Cluster Configuation for EMS and POMC Integrated (HP DL380+HP Disk Array+WIN2003+SQL2005)

    83/108

    The following prompt may appear during the installation process.

  • 7/31/2019 Cluster Configuation for EMS and POMC Integrated (HP DL380+HP Disk Array+WIN2003+SQL2005)

    84/108

    ClickOKto continue.

  • 7/31/2019 Cluster Configuation for EMS and POMC Integrated (HP DL380+HP Disk Array+WIN2003+SQL2005)

    85/108

    ClickNext to continue, and the Installation Complete window appears.

  • 7/31/2019 Cluster Configuation for EMS and POMC Integrated (HP DL380+HP Disk Array+WIN2003+SQL2005)

    86/108

    ClickNext to continue, and the Additional Information window appears.

  • 7/31/2019 Cluster Configuation for EMS and POMC Integrated (HP DL380+HP Disk Array+WIN2003+SQL2005)

    87/108

    Do not checkLaunch the User Provisioning Tool for Windows Vista after SP2 installation

    completes, and just clickFinish.

    5.3 SQL2005 SE Basic Settings

    Only when some settings are made after installation can SQL2005 SE can run normally. The

    settings required are as follows.

    Memory Configuration: Select dynamic memory, minimum server memory: 0, maximum

    server memory: 2147483647, and set minimum memory per query to

    2048KB.

  • 7/31/2019 Cluster Configuation for EMS and POMC Integrated (HP DL380+HP Disk Array+WIN2003+SQL2005)

    88/108

    Processors configuration: maximum worker threads: 255 (default)

  • 7/31/2019 Cluster Configuation for EMS and POMC Integrated (HP DL380+HP Disk Array+WIN2003+SQL2005)

    89/108

    Connection timeout: set remote query timeout to 60 seconds.

  • 7/31/2019 Cluster Configuation for EMS and POMC Integrated (HP DL380+HP Disk Array+WIN2003+SQL2005)

    90/108

    Recovery mode: Simple

    Compatibility level: 90 (default)

    Recovery: TornPageDetection (default: Checksum)

    Automatic: Auto Create Statistics: True

  • 7/31/2019 Cluster Configuation for EMS and POMC Integrated (HP DL380+HP Disk Array+WIN2003+SQL2005)

    91/108

    Data files and log files

    Run Microsoft SQL Server Management Studio and expand the navigation tree and select

    from under Database the database names to be configured (master and temp), and right-

    click and select Properties from the pop-up menu. Select Files in the Database Properties

    window.

  • 7/31/2019 Cluster Configuation for EMS and POMC Integrated (HP DL380+HP Disk Array+WIN2003+SQL2005)

    92/108

    Settings:

    Master database: Data files: 200MB, log files: 100MB

    Temp database: Data files: 200MB, log files: 100MB

    Network Configuration

    Protocols: TCP/IP and named pipes are used on both client and server.

    TCP/IP Properties: Default TCP port at the server side: 1433, Default TCP port

    at the client side: 1433

    Enable Shared Memory if client and server are installed on one machine.

  • 7/31/2019 Cluster Configuation for EMS and POMC Integrated (HP DL380+HP Disk Array+WIN2003+SQL2005)

    93/108

  • 7/31/2019 Cluster Configuation for EMS and POMC Integrated (HP DL380+HP Disk Array+WIN2003+SQL2005)

    94/108

    Note that the version installed is SQL SERVER 2005.

  • 7/31/2019 Cluster Configuation for EMS and POMC Integrated (HP DL380+HP Disk Array+WIN2003+SQL2005)

    95/108

  • 7/31/2019 Cluster Configuation for EMS and POMC Integrated (HP DL380+HP Disk Array+WIN2003+SQL2005)

    96/108

    Chapter 6 Installing Network ManagementServer on Cluster

    6.1 Installing Core Network and Wireless Side OMC

    Prerequisites and precautions:

    1. Stop SNMP Service on both servers

    The wireless-side network management system is installed on Disk Q of

    the shared disk array, and the CN NMS is installed on Disk N of the

    shared disk array. The NMS may be installed on the server with the disk

    array attached, and it is of no need to install NMS on both servers.

    2. In the Configure Database window of NMS installation, the IP address

    of the virtual SQL server should be entered as he database server IP, and

    the installation path should be one on the disk array.

    3. The step of executing database script may take some time since

    acquiring SQL2005 Server information at the first time will take some

    time. Please wait and do not exit.

    4. Refer to the installation guide released together with the software for

    detailed steps about OMC NMS installation.

    5. Replace ums-license.LCS with a file with no MAC bond after installation.

    Otherwise the OMC may not start in case switchover.

    6. CORBA is not installed and configured on either CN OMC or wireless-

    side OMC be cause of cluster switchover, which will be improved later.

    7. Ports need also be changed since the two NMSs may run on one server.

    The wireless side may use the default port, and the port for CN side

    need be changed. See the attached file below for details.

    Descri pti on onI nstal l ati on of E

    6.2 Configuring MSCS

    When installed, the two NMSs need be added as resources to their cluster

    groups respectively. Before doing so, modify the NMS startup script first, and

  • 7/31/2019 Cluster Configuation for EMS and POMC Integrated (HP DL380+HP Disk Array+WIN2003+SQL2005)

    97/108

    make it automatically clear original Java processes and notification service

    processes. Otherwise the NMS possibly can not start normally due to occupied

    address caused by resource switchover.

    6.2.1 Modifying NetNumen M3 (ZXC10 BSSB) Startup Script

    The operation may be made on Machine A, which takes over Group0, only. The

    following adopts POMC without CORBA.

    1. Do not start NetNumen M3 (ZXC10 BSSB).

    2. Copy files under in folder Q:\NetNumenM3\ums\ums-

    svr\tools\cluster\offline_win.vbs to folder Q:\NetNumenM3\ums\ums-

    svr\bin\.

    3. Enter Q:\NetNumenM3\ums\ums-svr\bin\, and open file

    offline_win.vbs with Notepad or another file editor.

    How to modify: Change the path of process java.exe to the actual path.

    Besides ending java processes, statements for deleting CORBA

    notification services, FTP services and notification service monitor

    program need also be added.

    a. Modify Q:\ NetNumenM3 \ums\ums-svr\bin\offline_win.vbs. The script is as follows.

    for each ps in getobject _

    ("winmgmts:\\.\root\cimv2:win32_process").instances_

    If ps.name = "notifyd.exe" Then

    wscript.echo ps.terminate

    End If

    If ps.name = "corbanotify.exe" Then

    wscript.echo ps.terminate

    End If

    If ps.name = "java.exe" Then

    if ps.executablepath = "Q:\ NetNumenM3\ums\jdk-

    windows\bin\java.exe" then

    wscript.echo ps.terminate

    end if

    End If

    If ps.name = "ftpserver.exe" Then

    wscript.echo ps.terminate

  • 7/31/2019 Cluster Configuation for EMS and POMC Integrated (HP DL380+HP Disk Array+WIN2003+SQL2005)

    98/108

    End If

    'wscript.echo ps.handle&vbtab&ps.name&vbtab&ps.executablepath

    Next

    b. Modify Q:\ NetNumenM3 \ums\ums-svr\bin\run.bat. The script is as follows.

    echo off

    title UMS Server

    cscript Q:\NetNumenM3\ums\ums-svr\bin\offline_win.vbs

    start Q:\NetNumenM3\ums\ums-svr\bin\runNTF.bat

    echo @SUBPROCESS_CMD_BEGIN@

    cd /d "%UMS_HOME%\tools\ftpserver"

    start /b Q:\NetNumenM3\ums\ums-svr\tools\ftpserver\ftpserver.bat

    echo @SUBPROCESS_CMD_END@

    c. Modify Q:\ NetNumenM3\ums\ums-svr\tools\ftpserver\ftpserver.bat. The script is as

    follows.

    set path=.\;Q:\NetNumenM3\ums\ums-svr\tools\ftpserver

    echo off

    title

    @if not "%ECHO%" == "" echo %ECHO%

    @if "%OS%" == "Windows_NT" setlocal

    6.2.2 Modifying OMC(ZX-EMS) Startup Script

    The operation may be made on Machine B, which takes over Group0, only.

    1. Do not start OMC (ZX-EMS).

    2. Copy files under in folder N:\EMSP4B3b\ems\ums-

    svr\tools\cluster\offline_win.vbs to folder N:\EMSP4B3b\ems\ums-

    svr \bin\.

    3. Enter N:\EMSP4B3b\ems\ums-svr \bin\, and open file offline_win.vbs

    with Notepad or another file editor. Modify and save the file.

    How to modify: Change the path of process java.exe to the actual path.

    Besides ending java processes, statements for deleting CORBA

    notification services, FTP services and notification service monitor

  • 7/31/2019 Cluster Configuation for EMS and POMC Integrated (HP DL380+HP Disk Array+WIN2003+SQL2005)

    99/108

    program need also be added.

    offline_win.vbs modified is as follows. The path is changed to the

    actual path.

    offline_win.vbs

    4. Modify file run.bat in folder N:\EMSP4B3b\ems\ums-svr\bin\, which is

    the startup script of OMC (ZX-EMS) server, with Notepad or another

    file editor. The file modified is as follows. The path is changed to the

    actual path.

    Run.bat

    5. Edit file tpserver.bat in folder N:\EMSP4B3b\ems\ums-

    svr\tools\ftpserver\. The file modified is as follows. The path is changed

    to the actual path.

    f tpserver. bat

    6. Modify EMS ports by editing file deploy-default.properties in folder

    N:\EMSP4B3b\ems\ums-svr\deploy. The file modified is as follows.

    depl oy-defaul t. properti es

    7. To modify license and make the two servers may be switched over,

    modify file ums-license.LCS in folder N:\EMSP4B3b\ems\ums-

    svr\deploy by unbind MAC address. The file modified is as follows.

    ums- l i cense.LCS

    8. To make the NMS start without CORBA, mask CORBA by modifying

    file deploy-uep-csp-ems-uCorba.xml in folder N:\EMSP4B3b\ems\ums-

    svr\deploy. The file modified is as follows.

  • 7/31/2019 Cluster Configuation for EMS and POMC Integrated (HP DL380+HP Disk Array+WIN2003+SQL2005)

    100/108

    depl oy-uep-csp-es- uCorba.xml

    6.2.3 Adding NMS Resources

    1. Select Start -> Administrative Tools -> Cluster Administrator to

    open the cluster administrator window.

    2. Nodes Groups, Resources, Cluster Configuration, and two server nodes

    are available under the root node. (Group Cluster Group is under the

    server node which currently takes over the cluster.) Select node Groups,

    groups Cluster Group, Group0 and Group1 will appear. Click a group,

    for example Group0 of POMC, all the resources of this group will

    appear in the right plane. Right-click on the empty part, and select New

    Resource to open the wizard for creating a resource. (The operation in

    CN NMS is similar to that in wireless side NMS, and the only

    difference is the group which an application resource is to be added to.)

    3. Enter a resource name, select resource type Common Application, and

    check the check box, as shown in Figure 6.2-33.

    Figure 6.2-33 Create A Resource

    4. ClickNext, and the node information will appear. Add the two servers,

    as shown in Figure 6.2-34.

  • 7/31/2019 Cluster Configuation for EMS and POMC Integrated (HP DL380+HP Disk Array+WIN2003+SQL2005)

    101/108

    Figure 6.2-34 Cluster Node

    5. ClickNext and specify dependencies. Select three resources which the

    NMS is dependent on: Cluster IP Address, shared disk (Disk Q for

    POMC, and Disk N for EMS), and SQL Server, as shown in Figure 6.2-

    35.

    Figure 6.2-35 NMS Resources Dependencies

    6. Click Next, and enter the application parameters interfaced with the

    MSCS. Enter the path and file name of run.bat, and check the two check

  • 7/31/2019 Cluster Configuation for EMS and POMC Integrated (HP DL380+HP Disk Array+WIN2003+SQL2005)

    102/108

    boxes, as shown in Figure 6.2-36. Note: The path must be the actual

    path. (Allow application to interact with desktop: The NMS server

    running window will appear, from which the server information may be

    seen. If this option is not selected, this window does not appear and theNMS program runs as a background process, but Java processes can

    still be seen in Task Manager.)

    Figure 6.2-36 General Application Parameters

    7. ClickNext, and the window for registration table copying appears. Do

    not enter anything and just clickFinish since NetNumen M3 (ZX-

    EMS) does not write registration table.

    Add CN NMS as a resource to Group1 by referring to the steps above.

    The configuration result is as shown in the two figures below.

    Result when POMC, the wireless-side NMS, is added to Group0 and is runningnormally:

  • 7/31/2019 Cluster Configuation for EMS and POMC Integrated (HP DL380+HP Disk Array+WIN2003+SQL2005)

    103/108

    Result when wireless-side EMS, the CN NMS, is added to Group0 and is

    running normally:

  • 7/31/2019 Cluster Configuation for EMS and POMC Integrated (HP DL380+HP Disk Array+WIN2003+SQL2005)

    104/108

    Now NMS resources are added and controlled under MSCS. MSCS mayautomatically run NMS respectively through online operations on NMS

    resources in the cluster administrator. To enter the mode of manual NMS

    debugging, right-click an NMS resource and select Offline, making the NMS

    out of the control of MSCS.

    6.3 Function and Switchover Test

    1. Manual Switchover Test:Switchover test is mainly performed in Cluster Administrator, and the

    switchover is made by groups. So to originate a switchover manually, just

    right-click the group (Group0 or Group1) and select Move Group. And

    then check the status change of the resources.

    Note:

    The NMS debugging window on the former active machine will not close

    automatically after the first switchover, which will not affect the NMS running

  • 7/31/2019 Cluster Configuation for EMS and POMC Integrated (HP DL380+HP Disk Array+WIN2003+SQL2005)

    105/108

    on the standby machine. Once the resource is switched over back to the active

    machine, the NMS script automatically clears the original process and the NMS

    restarts. This may be confirmed by the test.

    If NMS working normally after switchover is taken as the criteria, the time

    duration of resource switchover depends on the time necessary for the NMS to

    start. The whole switchover may take 6 to 7 minutes since the NMS may take 5

    minutes or more time to fully start. The duration will be shorter if the computer

    performance is higher.

    2. The server currently takes over the cluster should have the three

    features.

    (1) Besides the local public IP and heartbeat NIC IP, two virtual IP addressmay be seen with the ipconfig command. One is the virtual IP of SQL

    Server, and the other is cluster IP, that is, the virtual IP of the NMS for

    external access.

    (2) The arbitration disk and disk array disks assigned to this cluster group

    may be seen in Resource Manager.

    (3) It can be seen in Cluster Administrator that NMS resources and SQL

    resources are running on this server node and of course group Cluster

    Group is also running on this server node.

    3. The following scenes may be tested in the simulated environment.

    (1) Power off the server currently taking over the cluster, and check

    whether resources are successfully switched over to the standby

    machine.

    (2) Unplug both of the public network cables of the server currently taking

    over the cluster, and check whether resources are successfully switched

    over to the standby machine.

    (3) Manually close the NMS debugging window on the server currently

    taking over the cluster, and check whether the NMS restarts on this

    computer. (The protection strategy is: The applications try to restart on

    this computer incase of application failure, and only when applications

    fail to restart does the switchover take place in case.)

    4. The following points should be noted during NMS function test.

    (1) When logging on the NMS at the client, enter the NMS virtual IPaddress, i.e. the cluster IP. The virtual IP address remains the same no

  • 7/31/2019 Cluster Configuation for EMS and POMC Integrated (HP DL380+HP Disk Array+WIN2003+SQL2005)

    106/108

    matter which server of the cluster the NMS is running on. The virtual IP

    address need also be entered as the IP of the superior NMS when a

    junior NMS is being installed.

    (2) A short-time link break between client and server occurs in case of

    resource switchover. Re-log on the NMS after the switchover, and the

    link recovers.

    (3) The CORBA function is currently not supported since the function is

    rarely used.

    (4) Test NMS functions when the NMS is running on Machine A and when

    it is running on Machine B.

    6.4 Upgrading NMS Configuration on Cluster

    6.4.1 Prerequisites

    6.4.1.1 NMS Resources Offline

    Perform NMS resources offline operations on the server taking over the disk array. Click Start ->

    Administrative Tools -> Cluster Administrator to open the cluster administrator as shown in the

    figure below. Click node Group0 or Group1 under Groups, right-clickPOMC in the right plane,

    and select Offline. (Operation on CN EMS is the same.)

    Figure 6.4-37 Resource Offline

    6.4.1.2 Environment Check

    After NMS resource offline, perform environment check on the server taking over the disk array to

    check whether the environment contains JAVA process. End the JAVA process if there is any.

  • 7/31/2019 Cluster Configuation for EMS and POMC Integrated (HP DL380+HP Disk Array+WIN2003+SQL2005)

    107/108

    6.4.1.3 System Backup

    System backup refers to back up the original file system and database data of the OMC. The details

    about the operation are omitted here.

    6.4.1.4 Upgrading Installation

    Refer to relevant documents for details about upgrading installation.

    6.4.1.5 Patch Installation

    Refer to relevant documents for details about patch installation.

    6.4.1.6 Checks after Upgrading

    Check script files modified before after installation. Note that the file path of upgrading installation

    should be the same with script file path and the path in the script file also.

    Try to start the client and server in offline mode to check whether they can start up.

    6.4.2 Works after Upgrading

    1. In the Cluster Administrator window, right-click resource POMC or EMC and select

    Properties from the pop-up menu, and then modify the path to make it identical with the

    one before upgrading, thus to ensure the NMS may start up in the cluster environment.

    The window is as shown in the figure below.

    Figure 6.4-38 General Application Parameters

    2. Perform NMS resources online operations on the server taking over the disk array.

    Click Start -> Administrative Tools -> Cluster Administrator to open the cluster

    administrator. Click node Group0 or Group1 under Groups, right-click a corresponding

  • 7/31/2019 Cluster Configuation for EMS and POMC Integrated (HP DL380+HP Disk Array+WIN2003+SQL2005)

    108/108

    NMS resource in the right plane, and select Online.