58
Presented on [Date] by [Author’s Name] (Edit the Master Slide to change this text) CLT Floor Design: Strength, Deflection and Vibrations Scott Breneman, PhD, PE, SE Senior Technical Director Architectural and Engineering Solutions WoodWorks – Wood Products Council Toward Taller Wood Buildings November 2014

CLT Floor Design: Strength, Deflection and · PDF fileCLT Floor Design: Strength, Deflection and Vibrations Scott Breneman, PhD, ... Machine Stress Rated or Visually Graded Dimensional

  • Upload
    vuongtu

  • View
    233

  • Download
    6

Embed Size (px)

Citation preview

Page 1: CLT Floor Design: Strength, Deflection and · PDF fileCLT Floor Design: Strength, Deflection and Vibrations Scott Breneman, PhD, ... Machine Stress Rated or Visually Graded Dimensional

Presented on [Date] by [Author’s Name]

(Edit the Master Slide to change this text)

CLT Floor Design:

Strength, Deflection and

Vibrations

Scott Breneman, PhD, PE, SE

Senior Technical Director

Architectural and Engineering Solutions

WoodWorks – Wood Products Council

Toward Taller Wood Buildings

November 2014

Page 2: CLT Floor Design: Strength, Deflection and · PDF fileCLT Floor Design: Strength, Deflection and Vibrations Scott Breneman, PhD, ... Machine Stress Rated or Visually Graded Dimensional

Product Standardization

Page 3: CLT Floor Design: Strength, Deflection and · PDF fileCLT Floor Design: Strength, Deflection and Vibrations Scott Breneman, PhD, ... Machine Stress Rated or Visually Graded Dimensional

CLT Composition

Planks in alternating directions

Page 4: CLT Floor Design: Strength, Deflection and · PDF fileCLT Floor Design: Strength, Deflection and Vibrations Scott Breneman, PhD, ... Machine Stress Rated or Visually Graded Dimensional

CLT Composition

Page 5: CLT Floor Design: Strength, Deflection and · PDF fileCLT Floor Design: Strength, Deflection and Vibrations Scott Breneman, PhD, ... Machine Stress Rated or Visually Graded Dimensional

CLT Product Standard

ANSI/APA PRG 320

• CLT Stress classes

• Quality Assurance testing

• Identification marking

Page 6: CLT Floor Design: Strength, Deflection and · PDF fileCLT Floor Design: Strength, Deflection and Vibrations Scott Breneman, PhD, ... Machine Stress Rated or Visually Graded Dimensional

Product Reports

Page 7: CLT Floor Design: Strength, Deflection and · PDF fileCLT Floor Design: Strength, Deflection and Vibrations Scott Breneman, PhD, ... Machine Stress Rated or Visually Graded Dimensional

Structural Composition of CLT

Laminations: (Per PRG 320-2012)

5/8” to 2” thick.

Machine Stress Rated or Visually Graded Dimensional Lumber or SCL

Dried to 12% Moisture Content before layup.

A common NA thickness is 1 3/8” (planed 2x stock)

PRG 320 provides thickness to width requirements of laminations

Page 8: CLT Floor Design: Strength, Deflection and · PDF fileCLT Floor Design: Strength, Deflection and Vibrations Scott Breneman, PhD, ... Machine Stress Rated or Visually Graded Dimensional

Structural Composition of CLT

Layers: (Per PRG 320-2012)

Oriented in orthogonal arrangement

Odd number of symmetric layers most common

Double parallel exterior layers permitted

Unbalanced layup permitted

Reference glu-lam adhesive standard (AITC 405)

Page 9: CLT Floor Design: Strength, Deflection and · PDF fileCLT Floor Design: Strength, Deflection and Vibrations Scott Breneman, PhD, ... Machine Stress Rated or Visually Graded Dimensional

Structural Composition of CLT

Panels, also known as Billets.

20 inch max thickness in PRG 320

Up to 8 ft or more wide per manufacturer and shipping

Up to 40 ft or more long per manufacturer and shipping

Major axis: stronger, stiffer, usually long direction

Minor axis: less strong and stiff, usually short direction

Page 10: CLT Floor Design: Strength, Deflection and · PDF fileCLT Floor Design: Strength, Deflection and Vibrations Scott Breneman, PhD, ... Machine Stress Rated or Visually Graded Dimensional

CLT Stress Grades

Stress Grade Major Strength

Direction

Minor Strength Direction

E1 1950f-1.7E MSR SPF #3 Spruce Pine Fir

E2 1650f-1.5E MSR DFL #3 Doug Fir Larch

E3 1200f-1.2E MSR Misc #3 Misc

E4 1950f-1.7E MSR SP #3 Southern Pine

V1 #2 Doug Fir Larch #3 Doug Fir Larch

V2 #1/#2 Spruce Pine Fir #3 Spruce Pine Fir

V3 #2 Southern Pine #3 Southern Pine

Non-mandatory in PRG 320. Other stress grades including SCL permitted

Page 11: CLT Floor Design: Strength, Deflection and · PDF fileCLT Floor Design: Strength, Deflection and Vibrations Scott Breneman, PhD, ... Machine Stress Rated or Visually Graded Dimensional

PRG 320 Defined Layups

Page 12: CLT Floor Design: Strength, Deflection and · PDF fileCLT Floor Design: Strength, Deflection and Vibrations Scott Breneman, PhD, ... Machine Stress Rated or Visually Graded Dimensional

Examples of CLT Configurations

3-ply 3-layer

5-ply 5-layer

6-ply 5-layer

9-ply 9-layer

5-ply 3-layer

7-ply 5-layer

8-ply 5-layer

9-ply 7-layer

Page 13: CLT Floor Design: Strength, Deflection and · PDF fileCLT Floor Design: Strength, Deflection and Vibrations Scott Breneman, PhD, ... Machine Stress Rated or Visually Graded Dimensional

Strength

Photos Courtesy Structurlam

Page 14: CLT Floor Design: Strength, Deflection and · PDF fileCLT Floor Design: Strength, Deflection and Vibrations Scott Breneman, PhD, ... Machine Stress Rated or Visually Graded Dimensional

Floors

Page 15: CLT Floor Design: Strength, Deflection and · PDF fileCLT Floor Design: Strength, Deflection and Vibrations Scott Breneman, PhD, ... Machine Stress Rated or Visually Graded Dimensional

Non-homogenous, anisotropic material

Structural Section Properties

Page 16: CLT Floor Design: Strength, Deflection and · PDF fileCLT Floor Design: Strength, Deflection and Vibrations Scott Breneman, PhD, ... Machine Stress Rated or Visually Graded Dimensional

Design Properties based on Extreme Fiber Model:

Flexural Capacity Check:

Mb ≤ (FbSeff)′

Mb = applied bending moment

(FbSeff)′ = adjusted bending capacity

Seff = effective section modulus

Fb = reference bending design value of outer lamination

Flexural Strength

Mb

Bending Stress

Reference: NDS 2015 & US CLT Handbook

Page 17: CLT Floor Design: Strength, Deflection and · PDF fileCLT Floor Design: Strength, Deflection and Vibrations Scott Breneman, PhD, ... Machine Stress Rated or Visually Graded Dimensional

Design Properties based on Extreme Fiber Model:

Flexural Capacity Check (ASD)

(FbSeff)′ = CD CM Ct CL (FbSeff)

Flexural Strength

Mb

Bending Stress

Commonly

1.0From Manufacturer*

Mb ≤ CD (1.0) (FbSeff)

per

NDS

Reference: NDS 2015 & US CLT Handbook

Page 18: CLT Floor Design: Strength, Deflection and · PDF fileCLT Floor Design: Strength, Deflection and Vibrations Scott Breneman, PhD, ... Machine Stress Rated or Visually Graded Dimensional

Design Properties based on Extreme Fiber Model:

Flexural Capacity Check (LRFD)

(FbSeff)′ = CM Ct CL (FbSeff) Kf ϕ λ

Flexural Strength

Mb

Bending Stress

Commonly

1.0From Manufacturer

Mb ≤ (1.0) (FbSeff) (2.54)(0.85) λ

per

NDS 2015

& CLT

Handbook

Reference: NDS 2015 & US CLT Handbook

Page 19: CLT Floor Design: Strength, Deflection and · PDF fileCLT Floor Design: Strength, Deflection and Vibrations Scott Breneman, PhD, ... Machine Stress Rated or Visually Graded Dimensional

Select acceptable CLT section

Given:

16 foot span floor

40 psf live load, 40 psf total dead load.

Assume:

one-way spanning action in major axis of CLT

ASD Dead + Live Flexural Demands:

Mb = w L2 / 8 = (40+40psf) (16ft)2 / 8 = 2560 lb-ft/ft

Design Example: Flexure

16 foot span

Page 20: CLT Floor Design: Strength, Deflection and · PDF fileCLT Floor Design: Strength, Deflection and Vibrations Scott Breneman, PhD, ... Machine Stress Rated or Visually Graded Dimensional

Try 5 ply, (6 7/8 in thick) CLT Grade V2 Section

Design Example: Flexure

Reference: ANSI/APA PRG 320-2012

Page 21: CLT Floor Design: Strength, Deflection and · PDF fileCLT Floor Design: Strength, Deflection and Vibrations Scott Breneman, PhD, ... Machine Stress Rated or Visually Graded Dimensional

ASD Flexural Capacity:

Dead + Live load, CD = 1.0

(FbSeff)′ = CD (1.0) (Fb Seff)

= 1.0 (1.0) (4675 lb-ft/ft)

= 4675 lb-ft/ft

Mb = 2560 lb-ft/ft ≤ F’b Seff = 4675 lb-ft/ft

Flexural Strength OK

Design Example: Flexure

16 foot span

Page 22: CLT Floor Design: Strength, Deflection and · PDF fileCLT Floor Design: Strength, Deflection and Vibrations Scott Breneman, PhD, ... Machine Stress Rated or Visually Graded Dimensional

Design Properties based on Extreme Fiber Model:

Shear Capacity Check:

Vplanar ≤ Fs(Ib/Q)eff′

Vplanar = applied shear

Fs (IbQeff) ′ = adjusted shear strength

Shear Strength

Vplanar

Shear Stress

Reference: NDS 2015 & US CLT Handbook

Page 23: CLT Floor Design: Strength, Deflection and · PDF fileCLT Floor Design: Strength, Deflection and Vibrations Scott Breneman, PhD, ... Machine Stress Rated or Visually Graded Dimensional

Design Properties based on Extreme Fiber Model:

Shear Capacity Check (ASD):

Fs(IbQ)eff′ = CM Ct (Fs(IbQ)eff) = CM Ct Vs

Vplanar ≤ (1.0) Vs

Shear Strength

Vplanar

Shear Stress

Commonly

1.0From Manufacturer for

Standard Sections

Reference: NDS 2015 & US CLT Handbook

Page 24: CLT Floor Design: Strength, Deflection and · PDF fileCLT Floor Design: Strength, Deflection and Vibrations Scott Breneman, PhD, ... Machine Stress Rated or Visually Graded Dimensional

Stiffness & Deflection

Major Axis Stiffness

EIeff,0 GAeff,0

Minor Axis Stiffness

EIeff,90 GAeff,90

Page 25: CLT Floor Design: Strength, Deflection and · PDF fileCLT Floor Design: Strength, Deflection and Vibrations Scott Breneman, PhD, ... Machine Stress Rated or Visually Graded Dimensional

Structural Material Assumptions

Assumptions Used in CLT Handbook and ANSI/APA

PRG 320-2012 to develop section properties.

Given lumber for a lamination with modulus of elasticity

for bending in major strength direction, E0, assume:

• E90 = E0 / 30

• G0 = E0 /16

• G90 = G0 / 10 = E0 / 160

Reference: US CLT Handbook & PRG 320

Page 26: CLT Floor Design: Strength, Deflection and · PDF fileCLT Floor Design: Strength, Deflection and Vibrations Scott Breneman, PhD, ... Machine Stress Rated or Visually Graded Dimensional

Flexural Stiffness

Bending Stress

EIeff

Shear Analogy Method

Reference: US CLT Handbook Chapter 3

Page 27: CLT Floor Design: Strength, Deflection and · PDF fileCLT Floor Design: Strength, Deflection and Vibrations Scott Breneman, PhD, ... Machine Stress Rated or Visually Graded Dimensional

Shear Stiffness

GAeff

Reference: US CLT Handbook Chapter 3

Shear Analogy Method

Page 28: CLT Floor Design: Strength, Deflection and · PDF fileCLT Floor Design: Strength, Deflection and Vibrations Scott Breneman, PhD, ... Machine Stress Rated or Visually Graded Dimensional

Flexural Stiffness

EIeff

GAeff

Important to develop properties of

new CLT Sections.

Not to use standard CLT Sections

Page 29: CLT Floor Design: Strength, Deflection and · PDF fileCLT Floor Design: Strength, Deflection and Vibrations Scott Breneman, PhD, ... Machine Stress Rated or Visually Graded Dimensional

Structural Section Properties

Values in RED provided by CLT manufacturer

Flexural Strength: FbSeff,0

Flexural Stiffness: EIeff,0

Shear Strength: Vs,0

Shear Stiffness: GAeff,0

FbSeff,90

EIeff,90

Vs,90

GAeff,90

Reference: PRG 320 and CLT Product Reports

Page 30: CLT Floor Design: Strength, Deflection and · PDF fileCLT Floor Design: Strength, Deflection and Vibrations Scott Breneman, PhD, ... Machine Stress Rated or Visually Graded Dimensional

General Purpose, 2 Way, Plate Action

Flexural Stiffness

EIeff,0 EIeff,90

Shear Stiffness:

5/6 GAeff,0 5/6 GAeff,90

5/6 from A′ = 5/6 A for rectangular sections

Deflection Calculations

Page 31: CLT Floor Design: Strength, Deflection and · PDF fileCLT Floor Design: Strength, Deflection and Vibrations Scott Breneman, PhD, ... Machine Stress Rated or Visually Graded Dimensional

General Purpose: 1 Way, Beam Action

Stiffness: EIeff,0 5/6 GAeff,0

Deflection Calculations

Can model multiple spans, cantilevers, etc.

Page 32: CLT Floor Design: Strength, Deflection and · PDF fileCLT Floor Design: Strength, Deflection and Vibrations Scott Breneman, PhD, ... Machine Stress Rated or Visually Graded Dimensional

Example Calculation:

Uniform loading on one way slab:

Beam Analysis using

Flexural Stiffness: EIeff,0

Shear Stiffness: 5/6 GAeff,0

Maximum Deflection @ Mid-Span

Example Deflection Calculations

16 foot span

5/6 GAeff

Design Example:

= 0.161 in + 0.02 in = 0.183 in

= L / 1050

w = 80 psf

Page 33: CLT Floor Design: Strength, Deflection and · PDF fileCLT Floor Design: Strength, Deflection and Vibrations Scott Breneman, PhD, ... Machine Stress Rated or Visually Graded Dimensional

Simplified Beam Deflections:

Given load pattern and support conditions:

Deflection Calculations

Span, L5/6 GAeff

Uniform load, w

Find Apparent Flexural Stiffness, EIapp, such that

EIapp

�����=�����

1 +11.5����� ������Reference: US CLT Handbook

Page 34: CLT Floor Design: Strength, Deflection and · PDF fileCLT Floor Design: Strength, Deflection and Vibrations Scott Breneman, PhD, ... Machine Stress Rated or Visually Graded Dimensional

Simplified Beam Deflections

For single span, simple loading patterns, Apparent Flexural

Stiffness, EIapp, to determine maximum (mid-span) deflection:

Deflection Calculations

US CLT Handbook

�����=�����

1 +16�����������������=

�����1 + ������� ������

NDS 2015

����= ����� �������= ���� �⁄ � = �� 16⁄

For Major Axis Spans:

Reference: US CLT Handbook & NDS 2015

Page 35: CLT Floor Design: Strength, Deflection and · PDF fileCLT Floor Design: Strength, Deflection and Vibrations Scott Breneman, PhD, ... Machine Stress Rated or Visually Graded Dimensional

Simplified Beam Deflections

For single span, simple loading patterns, Apparent Flexural

Stiffness, EIapp, to determine maximum (mid-span) deflection:

Deflection Calculations

�����=�����

1 +16�����������������=

�����1 + ������� ������

Loading End Supports Ks

Uniform Pinned 11.5

Fixed 57.6

Midspan Line Pinned 14.4

Fixed 57.6

Apparent Flexural Stiffness depends on Load Pattern and Support Conditions

Page 36: CLT Floor Design: Strength, Deflection and · PDF fileCLT Floor Design: Strength, Deflection and Vibrations Scott Breneman, PhD, ... Machine Stress Rated or Visually Graded Dimensional

Simplified Beam Deflections

For single span, simple loading patterns, Apparent Flexural

Stiffness, EIapp, to determine maximum (mid-span) deflection:

Deflection Calculations

�����=�����

1 +16�����������������=

�����1 + ������� ������

Apparent Flexural Stiffness depends on Span Length

L1 = 20 foot

������≠ ������L2 = 16 foot

Page 37: CLT Floor Design: Strength, Deflection and · PDF fileCLT Floor Design: Strength, Deflection and Vibrations Scott Breneman, PhD, ... Machine Stress Rated or Visually Graded Dimensional

Deformation to Long Term Loads

Creep Factor

� = ����� + �� NDS Eq 3.5-1

�������

Deflection due to short-term loading

Immediate deflection due to long term loading

2.0 for CLT in dry service conditions

Reference: US CLT Handbook & NDS 2015

Page 38: CLT Floor Design: Strength, Deflection and · PDF fileCLT Floor Design: Strength, Deflection and Vibrations Scott Breneman, PhD, ... Machine Stress Rated or Visually Graded Dimensional

Occupant perception of vibration is a highly recommended design

consideration.

One approach: CLT Handbook, Chapter 7

Calculated natural frequency of simple span:

� = 2.1882��

�����"�

Where:

EIapp = apparent stiffness for 1 foot strip, pinned supported, uniformly

loaded, simple span (Ks = 11.5) (lb-in2)

rrrr = specific gravity of the CLT

A = the cross section area (thickness x 12 inches) (in2)

Floor Vibration

Reference: US CLT Handbook, Chapter 7

Page 39: CLT Floor Design: Strength, Deflection and · PDF fileCLT Floor Design: Strength, Deflection and Vibrations Scott Breneman, PhD, ... Machine Stress Rated or Visually Graded Dimensional

CLT Handbook, Chapter 7 recommends,

Floor Vibration

Max span L

� = 2.1882��

�����"� ≥ 9.0&'

and

Reference: US CLT Handbook, Chapter 7

Page 40: CLT Floor Design: Strength, Deflection and · PDF fileCLT Floor Design: Strength, Deflection and Vibrations Scott Breneman, PhD, ... Machine Stress Rated or Visually Graded Dimensional

CLT Handbook, Chapter 7 Recommendations

Floor Vibration

Research by Lin Hu, et al. at

Experimental Verification – Results

0.04

0.03

0.02

0.01

0

0.05

0.06

0.07

0 5 10 15

Fundamental Natural Frequency (Hz)

20

Sta

tic D

efl

ecti

on

(in

ch

)

Criterion ( f/d^0.7>125.1)

Unacceptable

Marginal

Acceptable

Page 41: CLT Floor Design: Strength, Deflection and · PDF fileCLT Floor Design: Strength, Deflection and Vibrations Scott Breneman, PhD, ... Machine Stress Rated or Visually Graded Dimensional

CLT Handbook, Chapter 7 method:

Natural frequencies above 9 Hz and:

EIapp depends on L, so an iterative calculation required.

Only depends on CLT section properties, soS

Values calculated and provided by CLT Manufactures

16ft span example: V2 Grade 5 ply (6 7/8 in) L max = 16.7 feet.

Floor Vibration

Max span L

Reference: US CLT Handbook, Chapter 7

Page 42: CLT Floor Design: Strength, Deflection and · PDF fileCLT Floor Design: Strength, Deflection and Vibrations Scott Breneman, PhD, ... Machine Stress Rated or Visually Graded Dimensional

CLT Handbook, Chapter 7 Recommendations

Floor Vibration

Continuous multi-span floor

� L2 is the longest span

� Use the design method to determine L2

assuming it is a single span floor

Page 43: CLT Floor Design: Strength, Deflection and · PDF fileCLT Floor Design: Strength, Deflection and Vibrations Scott Breneman, PhD, ... Machine Stress Rated or Visually Graded Dimensional

CLT Handbook, Chapter 7 Recommendations

Floor Vibration

With Suspended Ceiling

Use the design method without

including the mass and stiffness

of the drywall

Page 44: CLT Floor Design: Strength, Deflection and · PDF fileCLT Floor Design: Strength, Deflection and Vibrations Scott Breneman, PhD, ... Machine Stress Rated or Visually Graded Dimensional

CLT Handbook, Chapter 7 Recommendations

Floor Vibration

With lightweight topping (<20 Ib./ft.2) and drywall

� Lightweight topping examples:

- Wood panel

- Gypsum board

- Cement fibreboard

� Use proposed design

method without including

the mass and stiffness of

the drywall and the topping

Page 45: CLT Floor Design: Strength, Deflection and · PDF fileCLT Floor Design: Strength, Deflection and Vibrations Scott Breneman, PhD, ... Machine Stress Rated or Visually Graded Dimensional

CLT Handbook, Chapter 7 Recommendations

Floor Vibration

With heavy topping ( >20 Ib./ft.2)

Preliminary Recommendations

• Use the design method

without including the mass

and stiffness of the heavy

topping to determine the

span

• Reduce the bare floor

stiffness and mass by

10%

Page 46: CLT Floor Design: Strength, Deflection and · PDF fileCLT Floor Design: Strength, Deflection and Vibrations Scott Breneman, PhD, ... Machine Stress Rated or Visually Graded Dimensional

Occupant perception of vibration a recommended design consideration

CLT Handbook, Chapter 7 recommends natural frequencies above 9 Hz

and:

Limitations:

• Potential advantages of topping slab stiffness not taken into account

• Potential advantages of multiple spans or other restraining details

• Long spans can be uneconomical to keep natural frequency above 9 Hz.

Floor Vibration

Max span L

Page 47: CLT Floor Design: Strength, Deflection and · PDF fileCLT Floor Design: Strength, Deflection and Vibrations Scott Breneman, PhD, ... Machine Stress Rated or Visually Graded Dimensional

SOM Timber Tower

Source: SOM Timber Tower Research Project, May 2013

Prototype Building

Page 48: CLT Floor Design: Strength, Deflection and · PDF fileCLT Floor Design: Strength, Deflection and Vibrations Scott Breneman, PhD, ... Machine Stress Rated or Visually Graded Dimensional

SOM Timber Tower

24 to 25 ft CLT

Floor Spans.

6.5 to 8.5 Hz Range

Page 49: CLT Floor Design: Strength, Deflection and · PDF fileCLT Floor Design: Strength, Deflection and Vibrations Scott Breneman, PhD, ... Machine Stress Rated or Visually Graded Dimensional

Long spans can be designed using CLT Handbook Criteria:

Keep Fundamental Frequency > 9 hz

Idealized as Single Span, Simply Supported Panels

24 foot spans result in ~12 inch thick or greater CLT floors.

Alternative Vibration Criteria

Page 50: CLT Floor Design: Strength, Deflection and · PDF fileCLT Floor Design: Strength, Deflection and Vibrations Scott Breneman, PhD, ... Machine Stress Rated or Visually Graded Dimensional

SOM Timber Tower

CIP R.C. Beam

Precast R.C. Beam

CLT Floor Panel

Steel dowels

Exterior Spandrel Beam

Rigid Panel to

Spandrel

Connection

Page 51: CLT Floor Design: Strength, Deflection and · PDF fileCLT Floor Design: Strength, Deflection and Vibrations Scott Breneman, PhD, ... Machine Stress Rated or Visually Graded Dimensional

Alternative: Use acceptance criteria which address low

frequency floors and alternative support configurations.

Calibration of dynamic modeling

with physical testing valuable

Alternative Vibration Criteria

Page 52: CLT Floor Design: Strength, Deflection and · PDF fileCLT Floor Design: Strength, Deflection and Vibrations Scott Breneman, PhD, ... Machine Stress Rated or Visually Graded Dimensional

SOM Timber Tower used:

AISC Design Guide 11, Velocity Criteria (Chapter 6)

Acceptance Criteria selected:

≤ 16,000 µ-in/sec w/ moderate walking in living areas

≤ 8,000 µ-in/sec w/ slow walking pace in sleeping areas.

AISC DG 11 suggests approximate velocity limit of human perception

8,000 µ-in/sec at 8 Hz and above.

AISC Design Guide 11 not for dynamic modeling of CLT floors

Alternative Vibration Criteria

SOM Timber Tower Resulted in 8” Thick Floor

Page 53: CLT Floor Design: Strength, Deflection and · PDF fileCLT Floor Design: Strength, Deflection and Vibrations Scott Breneman, PhD, ... Machine Stress Rated or Visually Graded Dimensional

Floor Panel to Floor Panel

Connection Styles

Interior Spline

Single Surface Spline

Double Surface Spline

Half Lap

Page 54: CLT Floor Design: Strength, Deflection and · PDF fileCLT Floor Design: Strength, Deflection and Vibrations Scott Breneman, PhD, ... Machine Stress Rated or Visually Graded Dimensional

Floor Panel to Wall

Connection Styles

Platform Frame

With Only Screws

Platform Frame with

Double Brackets

Platform Frame with

Single Brackets

Page 55: CLT Floor Design: Strength, Deflection and · PDF fileCLT Floor Design: Strength, Deflection and Vibrations Scott Breneman, PhD, ... Machine Stress Rated or Visually Graded Dimensional

Floor Panel to Wall

Connection Styles

Balloon Frame

With Supporting

Ledger

Platform Frame with

Hidden Bracket

Platform Frame with

Bracket

Page 56: CLT Floor Design: Strength, Deflection and · PDF fileCLT Floor Design: Strength, Deflection and Vibrations Scott Breneman, PhD, ... Machine Stress Rated or Visually Graded Dimensional

US CLT Handbook

1. Introduction

2. Manufacturing

3. Structural

4. Lateral

5. Connections

6. DOL and Creep

7. Vibration

8. Fire

9. Sound

10.Enclosure

11.Environmental

12.Lifting

www.masstimber.com

Page 57: CLT Floor Design: Strength, Deflection and · PDF fileCLT Floor Design: Strength, Deflection and Vibrations Scott Breneman, PhD, ... Machine Stress Rated or Visually Graded Dimensional

Presented on [Date] by [Author’s Name]

(Edit the Master Slide to change this text)

CLT Floor Design:

Strength, Deflection and

Vibrations

Scott Breneman, PhD, PE, SE

[email protected]

Page 58: CLT Floor Design: Strength, Deflection and · PDF fileCLT Floor Design: Strength, Deflection and Vibrations Scott Breneman, PhD, ... Machine Stress Rated or Visually Graded Dimensional

Scott Breneman, PhD, PE, SE

[email protected]

Project Assistance also available

at [email protected]

Questions?