RP-QT-127B Rev.0
QUALITECH INSPEÇÃO, REPARO E MANUTENÇÃO LTDA.
GENERAL NDT INSPECTION
CLIENT: OCEANRIG
VESSEL: CORCOVADO
PO N°: ORBRZ-0055-2015 WO N°: 1173-1
Date: 27/09/2015 Version: Original Volume: 1 of 1
RP-QT-127B Rev.0
CONTENT
SECTION 01 – EXECUTIVE SUMMARY REPORT
SECTION 02 – 196 – CCERTIFICATE OF THOROUGH EXAMINATION – RISER BRIDLE
SECTION 03 – 313.331 – LIQUID PENETRAN REPORT – ADARTOR BUSHING ROTARY
TABLE MAIN WELL
SECTION 04 – 315 – WALL THICKNESS REPORT – APV’s LEVEL 1 & 2
SECTION 05 – 326.300 – WALL THICKNESS REPORT – VACUUM DEGASSER
SECTION 06 – 334.911 – MPI REPORT – RISER RUNNING TOOL
SECTION 07 – 335.311 – MPI REPORT – FRAME
SECTION 08 – 335.321 – MPI & EDDY CURRENT REPORT – SPIDER
SECTION 09 – 335.935.005 – MPI REPORT – RISER RUNNING TOOL
SECTION 10 – 335.935.010 – MPI REPORT – RISER RUNNING TOOL
SECTION 11 – 345.600 – MPI REPORT – BAILS
SECTION 12 – 361.100 – MPI REPORT – CRANE KNUCKLE BOOM #1
SECTION 13 – 361.200 – MPI REPORT – CRANE KNUCKLE BOOM #2
SECTION 14 – 361.300 – MPI REPORT – CRANE KNUCKLE BOOM #3
SECTION 15 – 361.400 – MPI REPORT – CRANE KNUCKLE BOOM #4
SECTION 16 – NO SFI – CERTIFICATE OF TOUROUGH EXAMINATION – WIRE ROPE,
SHACKLES AND RUNNING TOOL
SECTION 17 – NO SFI – MPI REPORT – CONTAINER PAD EYE
RP-QT-127B Rev.0
SECTION 18 – NO SFI – PHOTOGRAPHIC REPORT – WATER LEAK PIPE
SECTION 19 – TECHNICIAN CERTIFICATE
SECTION 20 – COMPANY CERTIFICATE
Page 1 of 1
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box01-C, Anil, Jacarepaguá–RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-072B Rev.2
CERTIFICATE OF TEST AND THOROUGH EXAMINATION
Certificate Number: CTE-1173-052
Customer: Ocean Rig Color Code: Green
Location: Corcovado Inspection Procedure: ISO 2415
SFI Code: 196 Client WO: 2015-08327
Date of Examination: 11/10/2015 Manufacture: Certex
Date of Next Examination: 09/04/2016 Equipment Status: Ok
Identity No Description & Detail Of Equipment Location SWL Test Proof
Load
447842-1
447842-2
48mm x 27 mtrs 6x36 IWRC, Galvanized, Two Legs Wire Rope Sling with Master
Link and Thimble Eyes on Top and Legs Ending with Swivel Eye Latch Hook and
Thimble Eye
48mm x 27 mtrs 6x36 IWRC, Galvanized, Two Legs Wire Rope Sling with Master
Link and Thimble Eyes on Top and Legs Ending with Swivel Eye Latch Hook and
Thimble Eye
Riser Deck
Riser Deck
43 t /30°
43 t /30°
N/A
N/A
General Comment: NO DEFECTS WERE FOUND AT TIME OF THE INSPECTION.
I certify on behalf of the firm, Company, association or technician named below that the items described herein were tested and thereafter examined and were found to be free from cracks, flaws or other defects
Name / Qualification:
Bruno Cerri
Signed / Stamp:
Date of Inspection:
11/10/2015
Approved by:
This certification or Report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer,manufacture, seller, supplier repairer, or operator of any warranty, express or implied and Qualitech. Liability shall be limited to the acs and omissions of it's employees, agents and subcontractors. Under no circumstances shall Qualitech be liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse of or any defect in material, machinery, equipment, or other items other than defects in items actually inspected by Qualitech and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by Qualitech and which are covered by this certificate or report.The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to Qualitech personnel. The report does not purport to list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severety ratings in the report are based on the criteria shown in this report and are intended as a guideline only. No responsability is assumed for the control or correction of conditions.
Page 1 of 2
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box01-C, Anil, Jacarepaguá–RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-102B Rev.3
LIQUID PENETRANT INSPECTION REPORT
Client: Ocean Rig Date: 12/10/2015 Qualitech WO:1173 Report Number: DP-1173-003
P.O. Nr: N/A Location: Corcovado Inspection Procedure: PI-QT-04 Rev.1
SFI Code: 313.331 Client WO: 2015-07806 Surface: Clean
Equipment Description: Adaptor Bushing Rotary Table Main Well Aft Qty: 6 Size: N/A
Serial Number: N/A Reference Drawing N°: N/A
Specification: ASME Section V Material: Stainless steel Manufacture: N/A
Comment: Area Inspected: As per clients request a Visual and Liquid penetrating Inspection was carried out on 100% off the accessible critical and stress areas of the Adaptor Bushing Rotary Table Main Well Aft Result: No defects were found at time of inspection Conclusion: Acceptable to Specification Recommendations: Release for Use Continuation Attached: Yes
Name / Qualification: Bruno Cerri
SNT/LP-5655
Signed / Stamp: Date of Inspection: 12/10/2015
Approved By:
Test Method
Test Medium x Visible Fluorescent
Penetrant Type: VP 30 Water Washable:
Solvent removable :
Post emulsifier :
Batch Nr:
Cleaner type: Water
Developer: D 70
Black Light Unit: N/A
Maker: Metal Check
Maker: N/A
Maker: Metal Check
Maker: N/A
Batch Nr: 20890
Batch Nr:
Batch Nr: 21035
Serial Nr:
Component Temp: ≥4ᵒC to ≤40ᵒC Dwell Time: ≥10 min to≤60min Dev. Time: ≥10 min to ≤60min
UV-A Irradiance: uw/cm2 Ambient Light Level: 1500 Lux
Page 2 of 2
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box01-C, Anil, Jacarepaguá–RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-102B Rev.3
LIQUID PENETRANT INSPECTION REPORT
Client: Ocean Rig Report Number: DP-1173-003
P.O. Nr: N/A WO: 1173 Location: Corcovado
Item: Adaptor Bushing Rotary Table Main Well Aft
Inspection Details: As per clients request a Visual and liquid penetrating inspection was carried out on 100% of the accessible critical area of the Eye Bolt
Name & Qualification: Bruno Cerri
SNT/PT-5655
Signed/Stamp:
Date of Inspection: 12/10/2015
Approved By:
RP-QT-134 Rev.1
Project:
Location:
DW N°:
Description:
To:From:
Date:
Note:The Locator Drawing are for reference only & not to a actual scale size.
Rev.:1Scale: N/A
Legend
Point
APV´S VESSEL
Test Point Orientation
AB
C
AB
CB
A
CDD D
WO N°:
Apv´s
Sub Sea
2015-08331-DW-24
Apv´s Room Apv´s Room
Wall Thickness Survey
04/10/2015
QT-1153
0
AFTFoward 1A2A3A
Front View
Customer: Report No: 2015-08331-WT-024
W.O. No: Steel Grade: Mat / Velocity: Cromo e Molibdenio/5920m/s
Pipe Line:
Work Area:
N°Original
Thickness
Class Minimum Thickness
(mm)
Test Point O.D
Actual W.T. (2015)
Diminuation (%) 2015
Actual W.T. (2016)
Diminuation (%) 2016
Actual W.T. (2017)
Diminuation (%) 2017
Max Allow Diminuation
(mm)
Max Allow Diminuation
(%)Test Point Type
1A 12,5mm 559mm 14,4mm Pressure Vessel
1B 12,5mm 559mm 14,0mm Pressure Vessel
1C 12,5mm 559mm 14,5mm Pressure Vessel
1D 12,5mm 559mm 14,1mm Pressure Vessel
2A 12,5mm 559mm 14,5mm Pressure Vessel
2B 12,5mm 559mm 14,6mm Pressure Vessel
2C 12,5mm 559mm 14,3mm Pressure Vessel
2D 12,5mm 559mm 14,1mm Pressure Vessel
3A 12,5mm 559mm 14,3mm Pressure Vessel
3B 12,5mm 559mm 14,6mm Pressure Vessel
3C 12,5mm 559mm 14,8mm Pressure Vessel
3D 12,5mm 559mm 13,9mm Pressure Vessel
Substantial Corrosion
Below Class Minimum
Bruno Cerri
Comments: Wall Thickness Class Minimum Calculated in accordance with the client class requirements. Legend:
Inspector's Signature Date: Surveyor's Signature Approved By:04/10/2015
Design Pressure (psi): 207 Bar Qualification: SNT-TC-1A-UT 3269APV´S Room Lv2
APV-06 Flow Sheet / Dr'g No: 2015-08331-DW-24
INTEGRATE MANAGEMENT SYSTEM Page 1 of 32
Title:
WALL THICKNESS PIPE LINE SURVEY REPORT
Inspector:
N/A
Ocean Rig SFI Code: 315 Client WO: 2015-08331
1173 Line Number: ASTM A519 Gr 4130
Location: Mylos
RP-QT-116 Rev.02
Customer: Report No: 2015-08331-WT-024
W.O. No: Steel Grade: Mat / Velocity: Cromo e Molibideno/5920m/s
Pipe Line:
Work Area:
N°Original
Thickness
Class Minimum Thickness
(mm)
Test Point O.D
Actual W.T. (2015)
Diminuation (%) 2015
Actual W.T. (2016)
Diminuation (%) 2016
Actual W.T. (2017)
Diminuation (%) 2017
Max Allow Diminuation
(mm)
Max Allow Diminuation
(%)Test Point Type
1A 12,5mm 559mm 15,2mm Pressure Vessel
1B 12,5mm 559mm 14,3mm Pressure Vessel
1C 12,5mm 559mm 14,6mm Pressure Vessel
1D 12,5mm 559mm 14,0mm Pressure Vessel
2A 12,5mm 559mm 13,9mm Pressure Vessel
2B 12,5mm 559mm 13,8mm Pressure Vessel
2C 12,5mm 559mm 15,1mm Pressure Vessel
2D 12,5mm 559mm 15,2mm Pressure Vessel
3A 12,5mm 559mm 14,9mm Pressure Vessel
3B 12,5mm 559mm 15,3mm Pressure Vessel
3C 12,5mm 559mm 15,6mm Pressure Vessel
3D 12,5mm 559mm 14,1mm Pressure Vessel
Substantial Corrosion
Below Class MinimumComments: Wall Thickness Class Minimum Calculated in accordance with the client class requirements. Legend:
Inspector's Signature Date: Surveyor's Signature Approved By:04/10/2015
APV´S Room Lv1 Design Pressure (psi): 207 Bar Qualification: SNT-TC-1A-UT- 3269
APV-48 Flow Sheet / Dr'g No: Inspector: Bruno Cerri
Page 31 of 32
Title:
WALL THICKNESS PIPE LINE SURVEY REPORT
1173 Line Number: N/A o e Molibednio ASTM A519 Gr
Ocean Rig Location: Mylos SFI Code: 315 Client WO: 2015-08331
INTEGRATE MANAGEMENT SYSTEM
RP-QT-116 Rev.02
RP-QT-134 Rev.1
Project:
Location:
DW N°:
Description:
To:From:
Date:
Note:The Locator Drawing are for reference only & not to a actual scale size.
Rev.:1Scale: N/A
Legend
Point
Vacuum Degassers
WO N°:
Vacuum Dagassers VP-152
Mux Processor Room
DW-36
Mux Processor Room
Wall Thickness Survey
02/10/2015
QT-1173
0
1
2
Portside
4
3
5
6
9
8
Foward
Tank Top Weldment Tank Bottom Weldment
Test Point Orientation
AB
C
AB
CB
A
C
DDD
7
Mux Processor Room
11
Starboardside AFT
12
13
14
15
16
17
Foward19
18
Weld
10
RP-QT-134 Rev.1
Project:
Location:
DW N°:
Description:
To:From:
Date:
Note:The Locator Drawing are for reference only & not to a actual scale size.
Rev.:1Scale: N/A
Legend
Point
Vacuum Degassers
WO N°:
Vacuum Dagassers VP-152
Mux Processor Room
DW-36
Mux Processor Room
Wall Thickness Survey
02/10/2015
QT-1173
0
1
2
Portside
4
3
5
6
9
8
Foward
Tank Top Weldment Tank Bottom Weldment
Test Point Orientation
AB
C
AB
CB
A
C
DDD
10
7
Mux Processor Room
11
Starboardside AFT
12
13
14
15
16
17
Foward
19
18
Weld
20
Customer: Report No: 2015-08317-WT-031
W.O. No: Steel Grade: Mat / Velocity: Cromo e Molibideno/5920m/s
Pipe Line:
Work Area:
N°Original
Thickness
Class Minimum Thickness
(mm)
Test Point O.D
Actual W.T. (2015)
Diminuation (%) 2015
Actual W.T. (2016)
Diminuation (%) 2016
Actual W.T. (2017)
Diminuation (%) 2017
Max Allow Diminuation
(mm)
Max Allow Diminuation
(%)Test Point Type
1 8,5mm Low Pressure
2 8,9mm Low Pressure
3 8,8mm Low Pressure
4 9,1mm Low Pressure
5 9,1mm Low Pressure
6 8,7mm Low Pressure
7 9,2mm Low Pressure
8 9,0mm Low Pressure
9 8,8mm Low Pressure
10 9,4mm Low Pressure
11 8,6mm Low Pressure
12 9,4mm Low Pressure
13 8,7mm Low Pressure
14 9,0mm Low Pressure
15 9,5mm Low Pressure
16 9,1mm Low Pressure
17 8,9mm Low Pressure
18 9,3mm Low Pressure
19 9,3mm Low Pressure
Substantial Corrosion
Below Class Minimum
Bruno Cerri
Comments: Wall Thickness Class Minimum Calculated in accordance with the client class requirements. Legend:
Inspector's Signature Date: Surveyor's Signature Approved By:04/10/2015
Design Pressure (psi): N/A Qualification: SNT-TC-1A-UT- 3269Mux Processor Room
Vacuum Degasers VP-152 Flow Sheet / Dr'g No: DW-036
INTEGRATE MANAGEMENT SYSTEM Page 1 of 1
Title:
WALL THICKNESS PIPE LINE SURVEY REPORT
Inspector:
N/A
Ocean Rig SFI Code: 326.300 Client WO: 2015-08317
1173 Line Number: ASTM A519 Gr 4130
Location: Mylos
RP-QT-116 Rev.02
Page 1 of 2
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box01-C, Anil, Jacarepaguá–RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-097B Rev.4
MAGNETIC PARTICLE INSPECTION REPORT
Client: Ocean Rig Location: Corcovado (NS-40) Report Number: MPI-1173-020
P.O. Nr: N/A Qualitech WO: 1173 Inspection Procedure: PI-QT-003 Rev.2
SFI Code: 334.911 Client WO: 2015-07476 Surface: Brushed
Equipment Description: Diverter Running Tool Qty: 1 Size: N/A
Serial Number: 20079432-02 Reference Drawing N°: N/A
Specification: ASTM E-709 Material: Carbon Steel Manufacture: NOV
Comment: Area Inspected: As per clients request a Visual and Magnetic Particle Inspection was carried out on 100% of the accessible critical area of the Diverter Running Tool Result: No defects were found at time of inspection. Conclusion: Acceptable to the Specification. Recommendations: Authorized for use. Continuation Attached: Yes
Name / Qualification: Bruno Cerri
SNT/MT-3276
Signed / Stamp:
Date of Inspection: 06/10/2015
Approved By:
Equipment/Magnetization
Magnetization Technique
Coil
Magnetization : Longitudinal Current Flow : Alternating
Ligth Type:
x Natural Artificial
x Yoke Pull 10lbs
Yes Pole Spacing:
4” to 6 “
Ilumination:1200 lux
Flux Indicator:
Berthold x Burmah Strip
Equipment Description: MY-2 Voltage: 110V Serial No:1303093
Test Method
Test Medium Dry X Colour Wet Wet Fluorescent
Particle Type: RW222
Contrast Type: 104
Antifoaming Type: 787
Black Light Unit: N/A
FL/Sample AT:
UV:0,1 to 0,4L
Visible:0,4 to 1,2L
Batch No:
Maker: Metal Check
Maker: Metal Check
Maker: Metal Check
Model: N/A
Batch Nr: 9884
Batch Nr: 7863
Batch Nr: 8733
Serial Nr: N/A
Page 2 of 2
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box01-C, Anil, Jacarepaguá–RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-097B Rev.4
MAGNETIC PARTICLE INSPECTION REPORT
Client: Petrobras Report Number: MPI-1173-020
P.O. Nr: N/A WO: 1173 Location: Corcovado (NS-40)
Item: Diverter Running Tool Inspection Details: As per clients request a Visual and Magnetic Particle Inspection was carried out on 100% of the accessible critical area of the Diverter Running Tool
Name & Qualification: Bruno Cerri
SNT/MT-3276
Signed/Stamp:
Date of Inspection: 06/10/2015
Approved By:
Page 1 of 2
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box01-C, Anil, Jacarepaguá–RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-097B Rev.4
MAGNETIC PARTICLE INSPECTION REPORT
Client: Ocean Rig Location: Corcovado (NS-40) Report Number: MPI-1173-027
P.O. Nr: N/A Qualitech WO: 1173 Inspection Procedure: PI-QT-003 Rev.2
SFI Code: 335.311 Client WO: 2015-03974 Surface: Brushed
Equipment Description: Frame Qty: 1 Size: 250 t
Serial Number: TF-01 Reference Drawing N°: N/A
Specification: ASTM E-709 Material: Carbon Steel Manufacture: N/A
Comment: Area Inspected: As per clients request a Visual and Magnetic Particle Inspection was carried out on 100% of the accessible critical area of the Frame. Result: No defects were found at time of inspection. Conclusion: Acceptable to the Specification. Recommendations: Authorized for use. Continuation Attached: Yes
Name / Qualification: Bruno Cerri
SNT/MT-3276
Signed / Stamp:
Date of Inspection: 12/10/2015
Approved By:
Equipment/Magnetization
Magnetization Technique
Coil
Magnetization : Longitudinal Current Flow : Alternating
Ligth Type:
x Natural Artificial
x Yoke Pull 10lbs
Yes Pole Spacing:
4” to 6 “
Ilumination:1200 lux
Flux Indicator:
Berthold x Burmah Strip
Equipment Description: MY-2 Voltage: 110V Serial No:1303093
Test Method
Test Medium Dry X Colour Wet Wet Fluorescent
Particle Type: RW222
Contrast Type: 104
Antifoaming Type: 787
Black Light Unit: N/A
FL/Sample AT:
UV:0,1 to 0,4L
Visible:0,4 to 1,2L
Batch No:
Maker: Metal Check
Maker: Metal Check
Maker: Metal Check
Model: N/A
Batch Nr: 9884
Batch Nr: 7863
Batch Nr: 8733
Serial Nr: N/A
Page 2 of 2
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box01-C, Anil, Jacarepaguá–RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-097B Rev.4
MAGNETIC PARTICLE INSPECTION REPORT
Client: Petrobras Report Number: MPI-1173-027
P.O. Nr: N/A WO: 1173 Location: Corcovado (NS-40)
Item: Frame Inspection Details: As per clients request a Visual and Magnetic Particle Inspection was carried out on 100% of the accessible critical area of the Frame.
Name & Qualification: Bruno Cerri
SNT/MT-3276
Signed/Stamp:
Date of Inspection: 12/10/2015
Approved By:
Page 1 of 2
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box01-C, Anil, Jacarepaguá–RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-104B Rev.2
EDDY CURRENT INSPECTION REPORT
Client: Ocean Rig Date: 07/10/15 Qualitech WO: Report Number: 2015-07648-EC-023
P.O. Nr: N/A Location: Corcovado Inspection Procedure: PI-QT-005 Rev.2
SFI Code: 335.321 Client WO: 2015-07648 Surface: Painted
Probes Probes Serial No Frequency Gain Phase Calibration
Absolute 501257/02 135-250 Khz 15 db 320 db Absolute
Bridge 503059/03 100 khz 40 db 72 db Bridge
NOTE: Compensations made for variable geometry and paint thickness.
Equipment Description: Spider
Serial Number: 20084370-1 Size: N/A
Manufacture: NOV Material: Carbon Steel Qty: 1
Specification: BSI BS-EN 1711 Reference Drawing N°: MPI-030
Comment: Area Inspected: As per clients request a Visual and Eddy Current Inspection was carried out on 100% of the accessible critical weld area of the Spider Result: No surface defects were found at time of inspection Conclusion: Acceptable to the Specification. Recommendations: Authorized for use Continuation Attached: Yes
Name / Qualification: Bruno Cerri
SNT-ET 5373
Signed / Stamp:
Date of Inspection: 07/10/2015
Approved By:
Equipments
Page 2 of 2
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box01-C, Anil, Jacarepaguá–RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-104B Rev.2
EDDIE CURRENT INSPECTION REPORT
Client: Ocean Rig Report Number: 2015-07648-EC-023
P.O. Nr: N/A WO: 1173 Location: Corcovado
Item: Spider Inspection Details: As per clients request a Visual and Eddy Current Inspection was carried out on 100% of the accessible critical weld area of the Spider.
Name & Qualification: Bruno Cerri
SNTC-ET 5373
Signed/Stamp:
Date of Inspection: 07/10/2015
Approved By:
Page 1 of 2
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box01-C, Anil, Jacarepaguá–RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-097B Rev.4
MAGNETIC PARTICLE INSPECTION REPORT
Client: Ocean Rig Location: Corcovado (NS-40) Report Number: MPI-1173-021
P.O. Nr: N/A Qualitech WO: 1173 Inspection Procedure: PI-QT-003 Rev.2
SFI Code: 335.321 Client WO: 2015-07648 Surface: Brushed
Equipment Description: Spider Qty: 1 Size: N/A
Serial Number: 20084370-1 Reference Drawing N°: N/A
Specification: ASTM E-709 Material: Carbon Steel Manufacture: NOV
Comment: Area Inspected: As per clients request a Visual and Magnetic Particle Inspection was carried out on 100% of the accessible critical area of the Spider. Result: No defects were found at time of inspection. Conclusion: Acceptable to the Specification. Recommendations: Authorized for use. Continuation Attached: Yes
Name / Qualification: Bruno Cerri
SNT/MT-3276
Signed / Stamp:
Date of Inspection: 07/10/2015
Approved By:
Equipment/Magnetization
Magnetization Technique
Coil
Magnetization : Longitudinal Current Flow : Alternating
Ligth Type:
x Natural Artificial
x Yoke Pull 10lbs
Yes Pole Spacing:
4” to 6 “
Ilumination:1200 lux
Flux Indicator:
Berthold x Burmah Strip
Equipment Description: MY-2 Voltage: 110V Serial No:1303093
Test Method
Test Medium Dry X Colour Wet Wet Fluorescent
Particle Type: RW222
Contrast Type: 104
Antifoaming Type: 787
Black Light Unit: N/A
FL/Sample AT:
UV:0,1 to 0,4L
Visible:0,4 to 1,2L
Batch No:
Maker: Metal Check
Maker: Metal Check
Maker: Metal Check
Model: N/A
Batch Nr: 9884
Batch Nr: 7863
Batch Nr: 8733
Serial Nr: N/A
Page 2 of 2
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box01-C, Anil, Jacarepaguá–RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-097B Rev.4
MAGNETIC PARTICLE INSPECTION REPORT
Client: Petrobras Report Number: MPI-1173-021
P.O. Nr: N/A WO: 1173 Location: Corcovado (NS-40)
Item: Spider Inspection Details: As per clients request a Visual and Magnetic Particle Inspection was carried out on 100% of the accessible critical area of the Spider.
Name & Qualification: Bruno Cerri
SNT/MT-3276
Signed/Stamp:
Date of Inspection: 07/10/2015
Approved By:
Page 1 of 2
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box01-C, Anil, Jacarepaguá–RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-097B Rev.4
MAGNETIC PARTICLE INSPECTION REPORT
Client: Ocean Rig Location: Corcovado (NS-40) Report Number: MPI-1173-022
P.O. Nr: Qualitech WO: 1173 Inspection Procedure: PI-QT-003 Rev.2
SFI Code: 335.935.005 Client WO: 2015-07650 Surface: Brushed
Equipment Description: Riser Running Tool Qty: 1 Size: N/A
Serial Number: 20079432-01 Reference Drawing N°: N/A
Specification: ASTM E-709 Material: Carbon Steel Manufacture: NOV
Comment: Area Inspected: As per clients request a Visual and Magnetic Particle Inspection was carried out on 100% of the accessible critical area of the Riser Running Tool. Result: No defects were found at time of inspection. Conclusion: Acceptable to the Specification. Recommendations: Authorized for use. Continuation Attached: Yes
Name / Qualification: Bruno Cerri
Signed / Stamp:
Date of Inspection: 06/10/2015
Approved By:
Equipment/Magnetization
Magnetization Technique
Coil
Magnetization : Longitudinal Current Flow : Alternating
Ligth Type:
x Natural Artificial
x Yoke Pull 10lbs
Yes Pole Spacing:
4” to 6 “
Ilumination:1200 lux
Flux Indicator:
Berthold x Burmah Strip
Equipment Description: MY-2 Voltage: 110V Serial No:1303093
Test Method
Test Medium Dry X Colour Wet Wet Fluorescent
Particle Type: RW222
Contrast Type: 104
Antifoaming Type: 787
Black Light Unit: N/A
FL/Sample AT:
UV:0,1 to 0,4L
Visible:0,4 to 1,2L
Batch No:
Maker: Metal Check
Maker: Metal Check
Maker: Metal Check
Model: N/A
Batch Nr: 9884
Batch Nr: 7863
Batch Nr: 8733
Serial Nr: N/A
Page 2 of 2
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box01-C, Anil, Jacarepaguá–RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-097B Rev.4
SNT/MT-3276
MAGNETIC PARTICLE INSPECTION REPORT
Client: Petrobras Report Number: MPI-1173-022
P.O. Nr: N/A WO: 1173 Location: Corcovado (NS-40)
Item: Riser Running Tool Inspection Details: As per clients request a Visual and Magnetic Particle Inspection was carried out on 100% of the accessible critical area of the Riser Running Tool.
Name & Qualification: Bruno Cerri
SNT/MT-3276
Signed/Stamp:
Date of Inspection: 06/10/2015
Approved By:
Page 1 of 2
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box01-C, Anil, Jacarepaguá–RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-097B Rev.4
MAGNETIC PARTICLE INSPECTION REPORT
Client: Ocean Rig Location: Corcovado (NS-40) Report Number: MPI1173-023
P.O. Nr: N/A Qualitech WO: 1173 Inspection Procedure: PI-QT-003 Rev.2
SFI Code: 335.935.010 Client WO: 2015-07651 Surface: Brushed
Equipment Description: Riser Running Tool Qty: 1 Size: N/A
Serial Number: 20079432-02 Reference Drawing N°: N/A
Specification: ASTM E-709 Material: Carbon Steel Manufacture: NOV
Comment: Area Inspected: As per clients request a Visual and Magnetic Particle Inspection was carried out on 100% of the accessible critical area of the Riser Running Tool. Result: No defects were found at time of inspection. Conclusion: Acceptable to the Specification. Recommendations: Authorized for use. Continuation Attached: Yes
Name / Qualification: Bruno Cerri
SNT/MT-3276
Signed / Stamp:
Date of Inspection: 06/10/2015
Approved By:
Equipment/Magnetization
Magnetization Technique
Coil
Magnetization : Longitudinal Current Flow : Alternating
Ligth Type:
x Natural Artificial
x Yoke Pull 10lbs
Yes Pole Spacing:
4” to 6 “
Ilumination:1200 lux
Flux Indicator:
Berthold x Burmah Strip
Equipment Description: MY-2 Voltage: 110V Serial No:1303093
Test Method
Test Medium Dry X Colour Wet Wet Fluorescent
Particle Type: RW222
Contrast Type: 104
Antifoaming Type: 787
Black Light Unit: N/A
FL/Sample AT:
UV:0,1 to 0,4L
Visible:0,4 to 1,2L
Batch No:
Maker: Metal Check
Maker: Metal Check
Maker: Metal Check
Model: N/A
Batch Nr: 9884
Batch Nr: 7863
Batch Nr: 8733
Serial Nr: N/A
Page 2 of 2
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box01-C, Anil, Jacarepaguá–RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-097B Rev.4
MAGNETIC PARTICLE INSPECTION REPORT
Client: Petrobras Report Number: MPI-1173-023
P.O. Nr: N/A WO: 1173 Location: Corcovado (NS-40)
Item: Riser Running Tool Inspection Details: As per clients request a Visual and Magnetic Particle Inspection was carried out on 100% of the accessible critical area of the Riser Running Tool.
Name & Qualification: Bruno Cerri
SNT/MT-3276
Signed/Stamp:
Date of Inspection: 06/10/2015
Approved By:
Page 1 of 2
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box01-C, Anil, Jacarepaguá–RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-097B Rev.4
MAGNETIC PARTICLE INSPECTION REPORT
Client: Ocean Rig Location: Corcovado (NS-40) Report Number: MPI-1173-024
P.O. Nr: N/A Qualitech WO: 1173 Inspection Procedure: PI-QT-003 Rev.2
SFI Code: 345.600 Client WO: 2015-07858 Surface: Brushed
Equipment Description: Bails Qty: 2 Size: 750 t
Serial Number: 39L/39R Reference Drawing N°: N/A
Specification: ASTM E-709 Material: Carbon Steel Manufacture: NOV
Comment: Area Inspected: As per clients request a Visual and Magnetic Particle Inspection was carried out on 100% of the accessible critical area of the Bails. Result: No defects were found at time of inspection. Conclusion: Acceptable to the Specification. Recommendations: Authorized for use. Continuation Attached: Yes
Name / Qualification: Bruno Cerri
ASNT/MT-3276
Signed / Stamp:
Date of Inspection: 09/10/2015
Approved By:
Equipment/Magnetization
Magnetization Technique
Coil
Magnetization : Longitudinal Current Flow : Alternating
Ligth Type:
x Natural Artificial
x Yoke Pull 10lbs
Yes Pole Spacing:
4” to 6 “
Ilumination:1200 lux
Flux Indicator:
Berthold x Burmah Strip
Equipment Description: MY-2 Voltage: 110V Serial No:1303093
Test Method
Test Medium Dry X Colour Wet Wet Fluorescent
Particle Type: RW222
Contrast Type: 104
Antifoaming Type: 787
Black Light Unit: N/A
FL/Sample AT:
UV:0,1 to 0,4L
Visible:0,4 to 1,2L
Batch No:
Maker: Metal Check
Maker: Metal Check
Maker: Metal Check
Model: N/A
Batch Nr: 9884
Batch Nr: 7863
Batch Nr: 8733
Serial Nr: N/A
Page 2 of 2
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box01-C, Anil, Jacarepaguá–RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-097B Rev.4
MAGNETIC PARTICLE INSPECTION REPORT
Client: Petrobras Report Number: MPI-1173-024
P.O. Nr: N/A WO: 1173 Location: Corcovado (NS-40)
Item: Bails Inspection Details: As per clients request a Visual and Magnetic Particle Inspection was carried out on 100% of the accessible critical area of the Bails.
Name & Qualification: Bruno Cerri
ASNT/MT-3276
Signed/Stamp:
Date of Inspection: 09/10/2015
Approved By:
Page 1 of 8
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box01-C, Anil, Jacarepaguá–RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-097B Rev.4
MAGNETIC PARTICLE INSPECTION REPORT
Client: Ocean Rig Location: Corcovado (NS-40) Report Number: MPI-1173-025
P.O. Nr: N/A Qualitech WO: 1173 Inspection Procedure: PI-QT-003 Rev.2
SFI Code: 361-100 Client WO: 2014-50523 Surface: Brushed
Equipment Description: Knuckle Boom Crane #1 (Before Repair) Qty: 1 Size: 85t
Serial Number: V3454-2210 Reference Drawing N°: N/A
Specification: ASTM E-709 Material: Carbon Steel Manufacture: NOV
Comment: Area Inspected: As per clients request a Visual and Magnetic Particle Inspection was carried out on 100% of the accessible critical area of the Knuckle Boom Crane #1 (Before Repair) Result: Cracks were found at time of inspection. Conclusion: No Acceptable to the Specification. Recommendations: Repair following procedures NOV. Continuation Attached: Yes
Name / Qualification: Bruno Cerri
SNT/MT-3276
Signed / Stamp:
Date of Inspection: 05/10/2015
Approved By:
Equipment/Magnetization
Magnetization Technique
Coil
Magnetization : Longitudinal Current Flow : Alternating
Ligth Type:
x Natural Artificial
x Yoke Pull 10lbs
Yes Pole Spacing:
4” to 6 “
Ilumination:1200 lux
Flux Indicator:
Berthold x Burmah Strip
Equipment Description: MY-2 Voltage: 110V Serial No:1303093
Test Method
Test Medium Dry X Colour Wet Wet Fluorescent
Particle Type: RW222
Contrast Type: 104
Antifoaming Type: 787
Black Light Unit: N/A
FL/Sample AT:
UV:0,1 to 0,4L
Visible:0,4 to 1,2L
Batch No:
Maker: Metal Check
Maker: Metal Check
Maker: Metal Check
Model: N/A
Batch Nr: 9884
Batch Nr: 7863
Batch Nr: 8733
Serial Nr: N/A
Page 2 of 8
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box01-C, Anil, Jacarepaguá–RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-097B Rev.4
MAGNETIC PARTICLE INSPECTION REPORT
Client: Petrobras Report Number: MPI-1173-025
P.O. Nr: N/A WO: 1173 Location: Corcovado (NS-40)
Item: Knuckle Boom Crane #1 (Before Repair) Inspection Details: As per clients request a Visual and Magnetic Particle Inspection was carried out on 100% of the accessible critical area of the Knuckle Boom Crane #1 (Before Repair) and Cracks were found at time.
Left Side
Right Side
Inspection before Repair
Name & Qualification: Bruno Cerri
SNT/MT-3276
Signed/Stamp:
Date of Inspection: 05/10/2015
Approved By:
Page 3 of 8
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box01-C, Anil, Jacarepaguá–RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-097B Rev.4
MAGNETIC PARTICLE INSPECTION REPORT
Client: Ocean Rig Location: Corcovado (NS-40) Report Number: MPI-1173-025
P.O. Nr: N/A Qualitech WO: 1173 Inspection Procedure: PI-QT-003 Rev.2
SFI Code: 361-100 Client WO: 2014-50523 Surface: Brushed
Equipment Description: Knuckle Boom Crane #1 Qty: 1 Size: 85t
Serial Number: V3454-2210 Reference Drawing N°: N/A
Specification: ASTM E-709 Material: Carbon Steel Manufacture: NOV
Comment: Area Inspected: As per clients request a Visual and Magnetic Particle Inspection was carried out on 100% of the accessible critical area of the Knuckle Boom Crane #1. Result: Were no cracks found at time of inspection. Conclusion: Acceptable to the Specification. Recommendations: Cracks removed following procedures NOV. Continuation Attached: Yes
Name / Qualification: Bruno Cerri
SNT/MT-3276
Signed / Stamp:
Date of Inspection: 05/10/2015
Approved By:
Equipment/Magnetization
Magnetization Technique
Coil
Magnetization : Longitudinal Current Flow : Alternating
Ligth Type:
x Natural Artificial
x Yoke Pull 10lbs
Yes Pole Spacing:
4” to 6 “
Ilumination:1200 lux
Flux Indicator:
Berthold x Burmah Strip
Equipment Description: MY-2 Voltage: 110V Serial No:1303093
Test Method
Test Medium Dry X Colour Wet Wet Fluorescent
Particle Type: RW222
Contrast Type: 104
Antifoaming Type: 787
Black Light Unit: N/A
FL/Sample AT:
UV:0,1 to 0,4L
Visible:0,4 to 1,2L
Batch No:
Maker: Metal Check
Maker: Metal Check
Maker: Metal Check
Model: N/A
Batch Nr: 9884
Batch Nr: 7863
Batch Nr: 8733
Serial Nr: N/A
Page 4 of 8
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box01-C, Anil, Jacarepaguá–RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-097B Rev.4
MAGNETIC PARTICLE INSPECTION REPORT
Client: Petrobras Report Number: MPI-1173-025
P.O. Nr: N/A WO: 1173 Location: Corcovado (NS-40)
Item: Knuckle Boom Crane #1 Inspection Details: As per clients request a Visual and Magnetic Particle Inspection was carried out on 100% of the accessible critical area of the Knuckle Boom Crane #1.
Left Side
Right Side
Cracks removed after Inspection
Name & Qualification:
Bruno Cerri SNT/MT-3276
Signed/Stamp:
Date of Inspection: 05/10/2015
Approved By:
Page 5 of 8
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box01-C, Anil, Jacarepaguá–RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-097B Rev.4
MAGNETIC PARTICLE INSPECTION REPORT
Client: Ocean Rig Location: Corcovado (NS-40) Report Number: MPI-1173-025
P.O. Nr: N/A Qualitech WO: 1173 Inspection Procedure: PI-QT-003 Rev.2
SFI Code: 361-100 Client WO: 2014-50523 Surface: Brushed
Equipment Description: Knuckle Boom Crane #1 (After Repair) Qty: 1 Size: 85t
Serial Number: V3454-2210 Reference Drawing N°: N/A
Specification: ASTM E-709 Material: Carbon Steel Manufacture: NOV
Comment: Area Inspected: As per clients request a Visual and Magnetic Particle Inspection was carried out on 100% of the accessible critical area of the Knuckle Boom Crane #1 (After Repair). Result: Were no cracks found at time of inspection. Conclusion: Acceptable to the Specification. Recommendations: Release for Use. Continuation Attached: Yes
Name / Qualification: Bruno Cerri
SNT/MT-3276
Signed / Stamp:
Date of Inspection: 05/10/2015
Approved By:
Equipment/Magnetization
Magnetization Technique
Coil
Magnetization : Longitudinal Current Flow : Alternating
Ligth Type:
x Natural Artificial
x Yoke Pull 10lbs
Yes Pole Spacing:
4” to 6 “
Ilumination:1200 lux
Flux Indicator:
Berthold x Burmah Strip
Equipment Description: MY-2 Voltage: 110V Serial No:1303093
Test Method
Test Medium Dry X Colour Wet Wet Fluorescent
Particle Type: RW222
Contrast Type: 104
Antifoaming Type: 787
Black Light Unit: N/A
FL/Sample AT:
UV:0,1 to 0,4L
Visible:0,4 to 1,2L
Batch No:
Maker: Metal Check
Maker: Metal Check
Maker: Metal Check
Model: N/A
Batch Nr: 9884
Batch Nr: 7863
Batch Nr: 8733
Serial Nr: N/A
Page 6 of 8
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box01-C, Anil, Jacarepaguá–RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-097B Rev.4
MAGNETIC PARTICLE INSPECTION REPORT
Client: Petrobras Report Number: MPI-1173-025
P.O. Nr: N/A WO: 1173 Location: Corcovado (NS-40)
Item: Knuckle Boom Crane #1 (After Repair) Inspection Details: As per clients request a Visual and Magnetic Particle Inspection was carried out on 100% of the accessible critical area of the Knuckle Boom Crane #1 (After Repair)
Left Side
Right Side
Inspection after Repair
Name & Qualification:
Bruno Cerri SNT/MT-3276
Signed/Stamp:
Date of Inspection: 05/10/2015
Approved By:
Page 7 of 8
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box01-C, Anil, Jacarepaguá–RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-097B Rev.4
MAGNETIC PARTICLE INSPECTION REPORT
Client: Ocean Rig Location: Corcovado (NS-40) Report Number: MPI-1173-025
P.O. Nr: N/A Qualitech WO: 1173 Inspection Procedure: PI-QT-003 Rev.2
SFI Code: 361-100 Client WO: 2014-50523 Surface: Brushed
Equipment Description: Knuckle Boom Crane #1 (After Weld Plate) Qty: 1 Size: 85t
Serial Number: V3454-2210 Reference Drawing N°: N/A
Specification: ASTM E-709 Material: Carbon Steel Manufacture: NOV
Comment: Area Inspected: As per clients request a Visual and Magnetic Particle Inspection was carried out on 100% of the accessible critical area of the Knuckle Boom Crane #1 (After Weld Plate). Result: Were no cracks found at time of Inspection. Conclusion: Acceptable to the Specification. Recommendations: Release for Use. Continuation Attached: Yes
Name / Qualification: Bruno Cerri
SNT/MT-3276
Signed / Stamp:
Date of Inspection: 13/10/2015
Approved By:
Equipment/Magnetization
Magnetization Technique
Coil
Magnetization : Longitudinal Current Flow : Alternating
Ligth Type:
x Natural Artificial
x Yoke Pull 10lbs
Yes Pole Spacing:
4” to 6 “
Ilumination:1200 lux
Flux Indicator:
Berthold x Burmah Strip
Equipment Description: MY-2 Voltage: 110V Serial No:1303093
Test Method
Test Medium Dry X Colour Wet Wet Fluorescent
Particle Type: RW222
Contrast Type: 104
Antifoaming Type: 787
Black Light Unit: N/A
FL/Sample AT:
UV:0,1 to 0,4L
Visible:0,4 to 1,2L
Batch No:
Maker: Metal Check
Maker: Metal Check
Maker: Metal Check
Model: N/A
Batch Nr: 9884
Batch Nr: 7863
Batch Nr: 8733
Serial Nr: N/A
Page 8 of 8
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box01-C, Anil, Jacarepaguá–RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-097B Rev.4
MAGNETIC PARTICLE INSPECTION REPORT
Client: Petrobras Report Number: MPI-1173-025
P.O. Nr: N/A WO: 1173 Location: Corcovado (NS-40)
Item: Knuckle Boom Crane #1 (After Weld Plate) Inspection Details: As per clients request a Visual and Magnetic Particle Inspection was carried out on 100% of the accessible critical area of the Knuckle Boom Crane #1 (After Weld Plate)
Left Side
Right Side
Inspection after Weld Plate
Name & Qualification:
Bruno Cerri SNT/MT-3276
Signed/Stamp:
Date of Inspection: 13/10/2015
Approved By:
Page 1 of 5
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box01-C, Anil, Jacarepaguá–RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-097B Rev.4
MAGNETIC PARTICLE INSPECTION REPORT
Client: Ocean Rig Location: Corcovado (NS-40) Report Number: MPI-1173-026
P.O. Nr: N/A Qualitech WO: 1173 Inspection Procedure: PI-QT-003 Rev.2
SFI Code: 361-200 Client WO: 2014-50523 Surface: Brushed
Equipment Description: Knuckle Boom Crane #2 Qty: 1 Size: 85t
Serial Number: V3455-2210 Reference Drawing N°: N/A
Specification: ASTM E-709 Material: Carbon Steel Manufacture: NOV
Comment: Area Inspected: As per clients request a Visual and Magnetic Particle Inspection was carried out on 100% of the accessible critical area of the Knuckle Boom Crane #2. Result: Cracks were found at time of inspection on Left Side. Conclusion: No Acceptable to the Specification. Recommendations: Repair following procedures NOV. Continuation Attached: Yes
Name / Qualification: Bruno Cerri
SNT/MT-3276
Signed / Stamp:
Date of Inspection: 14/10/2015
Approved By:
Equipment/Magnetization
Magnetization Technique
Coil
Magnetization : Longitudinal Current Flow : Alternating
Ligth Type:
x Natural Artificial
x Yoke Pull 10lbs
Yes Pole Spacing:
4” to 6 “
Ilumination:1200 lux
Flux Indicator:
Berthold x Burmah Strip
Equipment Description: MY-2 Voltage: 110V Serial No:1303093
Test Method
Test Medium Dry X Colour Wet Wet Fluorescent
Particle Type: RW222
Contrast Type: 104
Antifoaming Type: 787
Black Light Unit: N/A
FL/Sample AT:
UV:0,1 to 0,4L
Visible:0,4 to 1,2L
Batch No:
Maker: Metal Check
Maker: Metal Check
Maker: Metal Check
Model: N/A
Batch Nr: 9884
Batch Nr: 7863
Batch Nr: 8733
Serial Nr: N/A
Page 2 of 5
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box01-C, Anil, Jacarepaguá–RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-097B Rev.4
MAGNETIC PARTICLE INSPECTION REPORT
Client: Petrobras Report Number: MPI-1173-026
P.O. Nr: N/A WO: 1173 Location: Corcovado (NS-40)
Item: Knuckle Boom Crane #2 Inspection Details: As per clients request a Visual and Magnetic Particle Inspection was carried out on 100% of the accessible critical area of the Knuckle Boom Crane #2 and Cracks were found at time of inspection.
Left Side
Looking AFT to FOWARD
Name & Qualification:
Bruno Cerri SNT/MT-3276
Signed/Stamp:
Date of Inspection: 14/10/2015
Approved By:
Page 3 of 5
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box01-C, Anil, Jacarepaguá–RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-097B Rev.4
MAGNETIC PARTICLE INSPECTION REPORT
Client: Petrobras Report Number: MPI-1173-026
P.O. Nr: WO: 1173 Location: Corcovado (NS-40)
Item: Knuckle Boom Crane #2 Inspection Details: As per clients request a Visual and Magnetic Particle Inspection was carried out on 100% of the accessible critical area of the Knuckle Boom Crane #2.
Right Side
Looking AFT to FOWARD
Name & Qualification:
Bruno Cerri SNT/MT-3276
Signed/Stamp:
Date of Inspection: 14/10/2015
Approved By:
Page 4 of 5
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box01-C, Anil, Jacarepaguá–RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-097B Rev.4
MAGNETIC PARTICLE INSPECTION REPORT
Client: Ocean Rig Location: Corcovado (NS-40) Report Number: MPI-1173-026
P.O. Nr: N/A Qualitech WO: 1173 Inspection Procedure: PI-QT-003 Rev.2
SFI Code: 361-200 Client WO: 2014-50523 Surface: Brushed
Equipment Description: Knuckle Boom Crane #2 After Removed Crack
Qty: 1 Size: 85t
Serial Number: V3455-2210 Reference Drawing N°: N/A
Specification: ASTM E-709 Material: Carbon Steel Manufacture: NOV
Comment: Area Inspected: As per clients request a Visual and Magnetic Particle Inspection was carried out on 100% of the accessible critical area of the Knuckle Boom Crane #2. Result: No cracks were found at time of inspection and completed Removed. Conclusion: Acceptable to the Specification. Recommendations: Repaired following procedures NOV. Continuation Attached: Yes
Name / Qualification: Bruno Cerri
SNT/MT-3276
Signed / Stamp:
Date of Inspection: 17/10/2015
Approved By:
Equipment/Magnetization
Magnetization Technique
Coil
Magnetization : Longitudinal Current Flow : Alternating
Ligth Type:
x Natural Artificial
x Yoke Pull 10lbs
Yes Pole Spacing:
4” to 6 “
Ilumination:1200 lux
Flux Indicator:
Berthold x Burmah Strip
Equipment Description: MY-2 Voltage: 110V Serial No:1303093
Test Method
Test Medium Dry X Colour Wet Wet Fluorescent
Particle Type: RW222
Contrast Type: 104
Antifoaming Type: 787
Black Light Unit: N/A
FL/Sample AT:
UV:0,1 to 0,4L
Visible:0,4 to 1,2L
Batch No:
Maker: Metal Check
Maker: Metal Check
Maker: Metal Check
Model: N/A
Batch Nr: 9884
Batch Nr: 7863
Batch Nr: 8733
Serial Nr: N/A
Page 5 of 5
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box01-C, Anil, Jacarepaguá–RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-097B Rev.4
MAGNETIC PARTICLE INSPECTION REPORT
Client: Petrobras Report Number: MPI-1173-026
P.O. Nr: N/A WO: 1173 Location: Corcovado (NS-40)
Item: Knuckle Boom Crane #2 Inspection Details: As per clients request a Visual and Magnetic Particle Inspection was carried out on 100% of the accessible critical area of the Knuckle Boom Crane #2 After Removed Crack
Removed all Crack
Left Side
Looking AFT to FOWARD
Name & Qualification:
Bruno Cerri SNT/MT-3276
Signed/Stamp:
Date of Inspection: 17/10/2015
Approved By:
Page 1 of 2
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box01-C, Anil, Jacarepaguá–RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-097B Rev.4
MAGNETIC PARTICLE INSPECTION REPORT
Client: Ocean Rig Location: Corcovado (NS-40) Report Number: MPI-1173-028
P.O. Nr: N/A Qualitech WO: 1173 Inspection Procedure: PI-QT-003 Rev.2
SFI Code: 361-300 Client WO: 2014-50523 Surface: Brushed
Equipment Description: Knuckle Boom Crane #3 Qty: 1 Size: 85t
Serial Number: V3456-2210 Reference Drawing N°: N/A
Specification: ASTM E-709 Material: Carbon Steel Manufacture: NOV
Comment: Area Inspected: As per clients request a Visual and Magnetic Particle Inspection was carried out on 100% of the accessible critical area of the Knuckle Boom Crane #3. Result: Cracks were found at time of inspection. Conclusion: No Acceptable to the Specification. Recommendations: Repair following procedures NOV. Continuation Attached: Yes
Name / Qualification: Bruno Cerri
SNT/MT-3276
Signed / Stamp:
Date of Inspection: 11/10/2015
Approved By:
Equipment/Magnetization
Magnetization Technique
Coil
Magnetization : Longitudinal Current Flow : Alternating
Ligth Type:
x Natural Artificial
x Yoke Pull 10lbs
Yes Pole Spacing:
4” to 6 “
Ilumination:1200 lux
Flux Indicator:
Berthold x Burmah Strip
Equipment Description: MY-2 Voltage: 110V Serial No:1303093
Test Method
Test Medium Dry X Colour Wet Wet Fluorescent
Particle Type: RW222
Contrast Type: 104
Antifoaming Type: 787
Black Light Unit: N/A
FL/Sample AT:
UV:0,1 to 0,4L
Visible:0,4 to 1,2L
Batch No:
Maker: Metal Check
Maker: Metal Check
Maker: Metal Check
Model: N/A
Batch Nr: 9884
Batch Nr: 7863
Batch Nr: 8733
Serial Nr: N/A
Page 2 of 2
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box01-C, Anil, Jacarepaguá–RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-097B Rev.4
MAGNETIC PARTICLE INSPECTION REPORT
Client: Petrobras Report Number: MPI-1173-028
P.O. Nr: N/A WO: 1173 Location: Corcovado (NS-40)
Item: Knuckle Boom Crane #3 Inspection Details: As per clients request a Visual and Magnetic Particle Inspection was carried out on 100% of the accessible critical area of the Knuckle Boom Crane #3 and Cracks were found at time of inspection.
Left Side
Right Side
Looking Forward to AFT
Name & Qualification: Bruno Cerri
SNT/MT-3276
Signed/Stamp:
Date of Inspection: 11/10/2015
Approved By:
Page 1 of 11
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box01-C, Anil, Jacarepaguá–RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-097B Rev.4
MAGNETIC PARTICLE INSPECTION REPORT
Client: Ocean Rig Location: Corcovado (NS-40) Report Number: MPI-1173-029
P.O. Nr: N/A Qualitech WO: 1173 Inspection Procedure: PI-QT-003 Rev.2
SFI Code: 361-400 Client WO: 2014-50523 Surface: Brushed
Equipment Description: Knuckle Weld Boom Crane #4 Qty: 1 Size: 85t
Serial Number: V3457-2210 Reference Drawing N°: N/A
Specification: ASTM E-709 Material: Carbon Steel Manufacture: NOV
Comment: Area Inspected: As per clients request a Visual and Magnetic Particle Inspection was carried out on 100% of the accessible critical area of the Knuckle Weld Boom Crane #4. Result: Cracks were found at time of inspection on Both Side. Conclusion: No Acceptable to the Specification. Recommendations: Repair following procedures NOV. Continuation Attached: Yes
Name / Qualification: Bruno Cerri
SNT/MT-3276
Signed / Stamp:
Date of Inspection: 16/10/2015
Approved By:
Equipment/Magnetization
Magnetization Technique
Coil
Magnetization : Longitudinal Current Flow : Alternating
Ligth Type:
x Natural Artificial
x Yoke Pull 10lbs
Yes Pole Spacing:
4” to 6 “
Ilumination:1200 lux
Flux Indicator:
Berthold x Burmah Strip
Equipment Description: MY-2 Voltage: 110V Serial No:1303093
Test Method
Test Medium Dry X Colour Wet Wet Fluorescent
Particle Type: RW222
Contrast Type: 104
Antifoaming Type: 787
Black Light Unit: N/A
FL/Sample AT:
UV:0,1 to 0,4L
Visible:0,4 to 1,2L
Batch No:
Maker: Metal Check
Maker: Metal Check
Maker: Metal Check
Model: N/A
Batch Nr: 9884
Batch Nr: 7863
Batch Nr: 8733
Serial Nr: N/A
Page 2 of 11
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box01-C, Anil, Jacarepaguá–RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-097B Rev.4
MAGNETIC PARTICLE INSPECTION REPORT
Client: Ocean Rig Report Number: MPI-1173-029
P.O. Nr: N/A WO: 1173 Location: Corcovado (NS-40)
Item: Knuckle Weld Boom Crane #4 Inspection Details: As per clients request a Visual and Magnetic Particle Inspection was carried out on 100% of the accessible critical area of the Knuckle Weld Boom Crane #4 and Cracks were found at time of inspection.
Right Side
Looking AFT to FOWARD
Name & Qualification:
Bruno Cerri SNT/MT-3276
Signed/Stamp:
Date of Inspection: 16/10/2015
Approved By:
Page 3 of 11
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box01-C, Anil, Jacarepaguá–RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-097B Rev.4
MAGNETIC PARTICLE INSPECTION REPORT
Client: Ocean Rig Report Number: MPI-1173-029
P.O. Nr: N/A WO: 1173 Location: Corcovado (NS-40)
Item: Knuckle Weld Boom Crane #4 Inspection Details: As per clients request a Visual and Magnetic Particle Inspection was carried out on 100% of the accessible critical area of the Knuckle Weld Boom Crane #4, cracks were found at time of inspection
Left Side
Looking AFT to FOWARD
Name & Qualification:
Bruno Cerri SNT/MT-3276
Signed/Stamp:
Date of Inspection: 16/10/2015
Approved By:
Page 4 of 11
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box01-C, Anil, Jacarepaguá–RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-097B Rev.4
MAGNETIC PARTICLE INSPECTION REPORT
Client: Ocean Rig Location: Corcovado (NS-40) Report Number: MPI-1173-029
P.O. Nr: N/A Qualitech WO: 1173 Inspection Procedure: PI-QT-003 Rev.2
SFI Code: 361-400 Client WO: 2014-50523 Surface: Brushed
Equipment Description: Knuckle Weld Boom Crane #4 (After Removed Crack)
Qty: 1 Size: 85t
Serial Number: V3457-2210 Reference Drawing N°: N/A
Specification: ASTM E-709 Material: Carbon Steel Manufacture: NOV
Comment: Area Inspected: As per clients request a Visual and Magnetic Particle Inspection was carried out on 100% of the accessible critical area of the Knuckle Weld Boom Crane #4 (After Removed Crack). Result: No defects were found at time of inspection. Conclusion: No Acceptable to the Specification. Recommendations: Repair following procedures NOV. Continuation Attached: Yes
Name / Qualification: Bruno Cerri
SNT/MT-3276
Signed / Stamp:
Date of Inspection: 08/11/2015
Approved By:
Equipment/Magnetization
Magnetization Technique
Coil
Magnetization : Longitudinal Current Flow : Alternating
Ligth Type:
x Natural Artificial
x Yoke Pull 10lbs
Yes Pole Spacing:
4” to 6 “
Ilumination:1200 lux
Flux Indicator:
Berthold x Burmah Strip
Equipment Description: MY-2 Voltage: 110V Serial No:1303093
Test Method
Test Medium Dry X Colour Wet Wet Fluorescent
Particle Type: RW222
Contrast Type: 104
Antifoaming Type: 787
Black Light Unit: N/A
FL/Sample AT:
UV:0,1 to 0,4L
Visible:0,4 to 1,2L
Batch No:
Maker: Metal Check
Maker: Metal Check
Maker: Metal Check
Model: N/A
Batch Nr: 9884
Batch Nr: 7863
Batch Nr: 8733
Serial Nr: N/A
Page 5 of 11
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box01-C, Anil, Jacarepaguá–RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-097B Rev.4
MAGNETIC PARTICLE INSPECTION REPORT
Client: Ocean Rig Report Number: MPI-1173-029
P.O. Nr: N/A WO: 1173 Location: Corcovado (NS-40)
Item: Knuckle Weld Boom Crane #4 (After Removed Crack). Inspection Details: As per clients request a Visual and Magnetic Particle Inspection was carried out on 100% of the accessible critical area of the Knuckle Weld Boom Crane #4 (After Removed Crack).
Right Side
Looking AFT to FOWARD
Name & Qualification:
Bruno Cerri SNT/MT-3276
Signed/Stamp:
Date of Inspection: 08/11/2015
Approved By:
Page 6 of 11
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box01-C, Anil, Jacarepaguá–RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-097B Rev.4
MAGNETIC PARTICLE INSPECTION REPORT
Client: Ocean Rig Report Number: MPI-1173-029
P.O. Nr: N/A WO: 1173 Location: Corcovado (NS-40)
Item: Knuckle Weld Boom Crane #4 (After Removed Crack).Inspection Details: As per clients request a Visual and Magnetic Particle Inspection was carried out on 100% of the accessible critical area of the Knuckle Weld Boom Crane #4 (After Removed Crack).
Left Side
Looking AFT to FOWARD
Name & Qualification:
Bruno Cerri SNT/MT-3276
Signed/Stamp:
Date of Inspection: 08/11/2015
Approved By:
Page 7 of 11
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box01-C, Anil, Jacarepaguá–RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-097B Rev.4
MAGNETIC PARTICLE INSPECTION REPORT
Client: Ocean Rig Location: Corcovado (NS-40) Report Number: MPI-1173-029
P.O. Nr: N/A Qualitech WO: 1173 Inspection Procedure: PI-QT-003 Rev.2
SFI Code: 361-400 Client WO: 2014-50523 Surface: Brushed
Equipment Description: Knuckle Weld Boom Crane #4 (After Re-Weld)
Qty: 1 Size: 85t
Serial Number: V3457-2210 Reference Drawing N°: N/A
Specification: ASTM E-709 Material: Carbon Steel Manufacture: NOV
Comment: Area Inspected: As per clients request a Visual and Magnetic Particle Inspection was carried out on 100% of the accessible critical area of the Knuckle Weld Boom Crane #4 (After Re-Weld). Result: No defects were found at time of inspection. Conclusion: No Acceptable to the Specification. Recommendations: Repair following procedures NOV. Continuation Attached: Yes
Name / Qualification: Bruno Cerri
SNT/MT-3276
Signed / Stamp:
Date of Inspection: 08/11/2015
Approved By:
Equipment/Magnetization
Magnetization Technique
Coil
Magnetization : Longitudinal Current Flow : Alternating
Ligth Type:
x Natural Artificial
x Yoke Pull 10lbs
Yes Pole Spacing:
4” to 6 “
Ilumination:1200 lux
Flux Indicator:
Berthold x Burmah Strip
Equipment Description: MY-2 Voltage: 110V Serial No:1303093
Test Method
Test Medium Dry X Colour Wet Wet Fluorescent
Particle Type: RW222
Contrast Type: 104
Antifoaming Type: 787
Black Light Unit: N/A
FL/Sample AT:
UV:0,1 to 0,4L
Visible:0,4 to 1,2L
Batch No:
Maker: Metal Check
Maker: Metal Check
Maker: Metal Check
Model: N/A
Batch Nr: 9884
Batch Nr: 7863
Batch Nr: 8733
Serial Nr: N/A
Page 8 of 11
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box01-C, Anil, Jacarepaguá–RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-097B Rev.4
MAGNETIC PARTICLE INSPECTION REPORT
Client: Ocean Rig Report Number: MPI-1173-029
P.O. Nr: N/A WO: 1173 Location: Corcovado (NS-40)
Item: Knuckle Weld Boom Crane #4 (After Re-Weld). Inspection Details: As per clients request a Visual and Magnetic Particle Inspection was carried out on 100% of the accessible critical area of the Knuckle Weld Boom Crane #4 (After Re-Weld).
Right Side
Looking AFT to FOWARD
Name & Qualification:
Bruno Cerri SNT/MT-3276
Signed/Stamp:
Date of Inspection: 08/11/2015
Approved By:
Page 9 of 11
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box01-C, Anil, Jacarepaguá–RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-097B Rev.4
MAGNETIC PARTICLE INSPECTION REPORT
Client: Ocean Rig Location: Corcovado (NS-40) Report Number: MPI-1173-029
P.O. Nr: N/A Qualitech WO: 1173 Inspection Procedure: PI-QT-003 Rev.2
SFI Code: 361-400 Client WO: 2014-50523 Surface: Brushed
Equipment Description: Knuckle Weld Boom Crane #4 (Bracket Weld) Qty: 1 Size: 85t
Serial Number: V3457-2210 Reference Drawing N°: N/A
Specification: ASTM E-709 Material: Carbon Steel Manufacture: NOV
Comment: Area Inspected: As per clients request a Visual and Magnetic Particle Inspection was carried out on 100% of the accessible critical area of the Knuckle Weld Boom Crane #4 (Bracket Weld). Result: No defects were found at time of inspection. Conclusion: No Acceptable to the Specification. Recommendations: Repair following procedures NOV. Continuation Attached: Yes
Name / Qualification: Bruno Cerri
SNT/MT-3276
Signed / Stamp:
Date of Inspection: 09/11/2015
Approved By:
Equipment/Magnetization
Magnetization Technique
Coil
Magnetization : Longitudinal Current Flow : Alternating
Ligth Type:
x Natural Artificial
x Yoke Pull 10lbs
Yes Pole Spacing:
4” to 6 “
Ilumination:1200 lux
Flux Indicator:
Berthold x Burmah Strip
Equipment Description: MY-2 Voltage: 110V Serial No:1303093
Test Method
Test Medium Dry X Colour Wet Wet Fluorescent
Particle Type: RW222
Contrast Type: 104
Antifoaming Type: 787
Black Light Unit: N/A
FL/Sample AT:
UV:0,1 to 0,4L
Visible:0,4 to 1,2L
Batch No:
Maker: Metal Check
Maker: Metal Check
Maker: Metal Check
Model: N/A
Batch Nr: 9884
Batch Nr: 7863
Batch Nr: 8733
Serial Nr: N/A
Page 10 of 11
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box01-C, Anil, Jacarepaguá–RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-097B Rev.4
MAGNETIC PARTICLE INSPECTION REPORT
Client: Ocean Rig Report Number: MPI-1173-029
P.O. Nr: N/A WO: 1173 Location: Corcovado (NS-40)
Item: Knuckle Weld Boom Crane #4 (Bracket Weld) Inspection Details: As per clients request a Visual and Magnetic Particle Inspection was carried out on 100% of the accessible critical area of the Knuckle Weld Boom Crane #4 (Bracket Weld)
Right Side
Looking AFT to FOWARD
Name & Qualification:
Bruno Cerri SNT/MT-3276
Signed/Stamp:
Date of Inspection: 09/11/2015
Approved By:
Page 11 of 11
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box01-C, Anil, Jacarepaguá–RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-097B Rev.4
MAGNETIC PARTICLE INSPECTION REPORT
Client: Ocean Rig Report Number: MPI-1173-029
P.O. Nr: N/A WO: 1173 Location: Corcovado (NS-40)
Item: Knuckle Weld Boom Crane #4 (Bracket Weld) Inspection Details: As per clients request a Visual and Magnetic Particle Inspection was carried out on 100% of the accessible critical area of the Knuckle Weld Boom Crane #4 (Bracket Weld)
Left Side
Looking AFT to FOWARD
Name & Qualification:
Bruno Cerri SNT/MT-3276
Signed/Stamp:
Date of Inspection: 09/11/2015
Approved By:
Page 1 of 1
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box01-C, Anil, Jacarepaguá–RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-072B Rev.2
CERTIFICATE OF TEST AND THOROUGH EXAMINATION
Certificate Number: CTE-1173-053
Customer: Ocean Rig Color Code: Green
Location: Corcovado Inspection Procedure: ISO 2415
SFI Code: N/A Client WO: N/A
Date of Examination: 06/10/2015 Manufacture: Crosby
Date of Next Examination: 05/04/2016 Equipment Status: Ok
Identity No Description & Detail Of Equipment Location SWL Test Proof
Load
41259921 NVD- 3617 Safety Pin Bow Shackles Green Pin
Riser Deck 55 t N/A
General Comment: NO DEFECTS WERE FOUND AT TIME OF THE INSPECTION.
I certify on behalf of the firm, Company, association or technician named below that the items described herein were tested and thereafter examined and were found to be free from cracks, flaws or other defects
Name / Qualification:
Bruno Cerri
Signed / Stamp:
Date of Inspection:
06/10/2015
Approved by:
This certification or Report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer,manufacture, seller, supplier repairer, or operator of any warranty, express or implied and Qualitech. Liability shall be limited to the acs and omissions of it's employees, agents and subcontractors. Under no circumstances shall Qualitech be liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse of or any defect in material, machinery, equipment, or other items other than defects in items actually inspected by Qualitech and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by Qualitech and which are covered by this certificate or report.The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to Qualitech personnel. The report does not purport to list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severety ratings in the report are based on the criteria shown in this report and are intended as a guideline only. No responsability is assumed for the control or correction of conditions.
Page 1 of 5
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box01-C, Anil, Jacarepaguá–RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-072B Rev.2
CERTIFICATE OF TEST AND THOROUGH EXAMINATION
Certificate Number: CTE-1173-054
Customer: Ocean Rig Color Code: Green
Location: Corcovado Inspection Procedure: ISO 2415
SFI Code: N/A Client WO: N/A
Date of Examination: 06/10/2015 Manufacture: Global Lifting Services
Date of Next Examination: 05/04/2016 Equipment Status: Ok
Identity No Description & Detail Of Equipment Location SWL Test Proof
Load
W2-13-109/1 5 Leg Wire Rope Sling Soft Eye
1,14 mt x19 mm C/ 28mm Master Link Crosby CG81NV
Riser Deck 2,3 tonne N/A
General Comment: NO DEFECTS WERE FOUND AT TIME OF THE INSPECTION.
I certify on behalf of the firm, Company, association or technician named below that the items described herein were tested and thereafter examined and were found to be free from cracks, flaws or other defects
Name / Qualification:
Bruno Cerri
Signed / Stamp:
Date of Inspection:
06/10/2015
Approved by:
This certification or Report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer,manufacture, seller, supplier repairer, or operator of any warranty, express or implied and Qualitech. Liability shall be limited to the acs and omissions of it's employees, agents and subcontractors. Under no circumstances shall Qualitech be liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse of or any defect in material, machinery, equipment, or other items other than defects in items actually inspected by Qualitech and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by Qualitech and which are covered by this certificate or report.The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to Qualitech personnel. The report does not purport to list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severety ratings in the report are based on the criteria shown in this report and are intended as a guideline only. No responsability is assumed for the control or correction of conditions.
Page 2 of 5
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box01-C, Anil, Jacarepaguá–RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-072B Rev.2
CERTIFICATE OF TEST AND THOROUGH EXAMINATION
Certificate Number: CTE-1173-054
Customer: Ocean Rig Color Code: Green
Location: Corcovado Inspection Procedure: ISO 2415
SFI Code: N/A Client WO: N/A
Date of Examination: 06/10/2015 Manufacture: Global Lifting Services
Date of Next Examination: 05/04/2016 Equipment Status: Ok
Identity No Description & Detail Of Equipment Location SWL Test Proof
Load
W2-13-092/1 5 Leg wire rope sling Soft Eye
1,14 mt x 19mm C/ Master Link Crosby CG81NT
Riser Deck 2,3 tonne N/A
General Comment: NO DEFECTS WERE FOUND AT TIME OF THE INSPECTION.
I certify on behalf of the firm, Company, association or technician named below that the items described herein were tested and thereafter examined and were found to be free from cracks, flaws or other defects
Name / Qualification:
Bruno Cerri
Signed / Stamp:
Date of Inspection:
06/10/2015
Approved by:
This certification or Report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer,manufacture, seller, supplier repairer, or operator of any warranty, express or implied and Qualitech. Liability shall be limited to the acs and omissions of it's employees, agents and subcontractors. Under no circumstances shall Qualitech be liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse of or any defect in material, machinery, equipment, or other items other than defects in items actually inspected by Qualitech and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by Qualitech and which are covered by this certificate or report.The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to Qualitech personnel. The report does not purport to list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severety ratings in the report are based on the criteria shown in this report and are intended as a guideline only. No responsability is assumed for the control or correction of conditions.
Page 3 of 5
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box01-C, Anil, Jacarepaguá–RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-072B Rev.2
CERTIFICATE OF TEST AND THOROUGH EXAMINATION
Certificate Number: CTE-1173-054
Customer: Ocean Rig Color Code: Green
Location: Corcovado Inspection Procedure: ISO 2415
SFI Code: N/A Client WO: N/A
Date of Examination: 06/10/2015 Manufacture: Global Lifting Services
Date of Next Examination: 05/04/2016 Equipment Status: Ok
Identity No Description & Detail Of Equipment Location SWL Test Proof
Load
W2-13-148/1 5 Leg Wire Rope Sling Soft Eye
1,14 mt x19 mm C/ 28mm Master Link Crosby CG81NV
Riser Deck 2,3 tonne N/A
General Comment: NO DEFECTS WERE FOUND AT TIME OF THE INSPECTION.
I certify on behalf of the firm, Company, association or technician named below that the items described herein were tested and thereafter examined and were found to be free from cracks, flaws or other defects
Name / Qualification:
Bruno Cerri
Signed / Stamp:
Date of Inspection:
06/10/2015
Approved by:
This certification or Report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer,manufacture, seller, supplier repairer, or operator of any warranty, express or implied and Qualitech. Liability shall be limited to the acs and omissions of it's employees, agents and subcontractors. Under no circumstances shall Qualitech be liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse of or any defect in material, machinery, equipment, or other items other than defects in items actually inspected by Qualitech and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by Qualitech and which are covered by this certificate or report.The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to Qualitech personnel. The report does not purport to list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severety ratings in the report are based on the criteria shown in this report and are intended as a guideline only. No responsability is assumed for the control or correction of conditions
Page 4 of 5
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box01-C, Anil, Jacarepaguá–RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-072B Rev.2
CERTIFICATE OF TEST AND THOROUGH EXAMINATION
Certificate Number: CTE-1173-054
Customer: Ocean Rig Color Code: Green
Location: Corcovado Inspection Procedure: ISO 2415
SFI Code: N/A Client WO: N/A
Date of Examination: 06/10/2015 Manufacture: Global Lifting Services
Date of Next Examination: 05/04/2016 Equipment Status: Ok
Identity No Description & Detail Of Equipment Location SWL Test Proof
Load
W2-13-188/1 5 Leg Wire Rope Sling Soft Eye
1,14 mt x19 mm C/ 28mm Master Link Crosby CG81NV
Riser Deck 2,3 tonne N/A
General Comment: NO DEFECTS WERE FOUND AT TIME OF THE INSPECTION.
I certify on behalf of the firm, Company, association or technician named below that the items described herein were tested and thereafter examined and were found to be free from cracks, flaws or other defects
Name / Qualification:
Bruno Cerri
Signed / Stamp:
Date of Inspection:
06/10/2015
Approved by:
This certification or Report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer,manufacture, seller, supplier repairer, or operator of any warranty, express or implied and Qualitech. Liability shall be limited to the acs and omissions of it's employees, agents and subcontractors. Under no circumstances shall Qualitech be liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse of or any defect in material, machinery, equipment, or other items other than defects in items actually inspected by Qualitech and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by Qualitech and which are covered by this certificate or report.The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to Qualitech personnel. The report does not purport to list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severety ratings in the report are based on the criteria shown in this report and are intended as a guideline only. No responsability is assumed for the control or correction of conditions
Page 5 of 5
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box01-C, Anil, Jacarepaguá–RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-072B Rev.2
CERTIFICATE OF TEST AND THOROUGH EXAMINATION
Certificate Number: CTE-1173-054
Customer: Ocean Rig Color Code: Green
Location: Corcovado Inspection Procedure: ISO 2415
SFI Code: N/A Client WO: N/A
Date of Examination: 06/10/2015 Manufacture: Global Lifting Services
Date of Next Examination: 05/04/2016 Equipment Status: Ok
Identity No Description & Detail Of Equipment Location SWL Test Proof
Load
W2-13-190/1 5 Leg Wire Rope Sling Soft Eye
1,14 mt x19 mm C/ 28mm Master Link Crosby CG81NV
Riser Deck 2,3 tonne N/A
General Comment: NO DEFECTS WERE FOUND AT TIME OF THE INSPECTION.
I certify on behalf of the firm, Company, association or technician named below that the items described herein were tested and thereafter examined and were found to be free from cracks, flaws or other defects
Name / Qualification:
Bruno Cerri
Signed / Stamp:
Date of Inspection:
06/10/2015
Approved by:
This certification or Report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer,manufacture, seller, supplier repairer, or operator of any warranty, express or implied and Qualitech. Liability shall be limited to the acs and omissions of it's employees, agents and subcontractors. Under no circumstances shall Qualitech be liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse of or any defect in material, machinery, equipment, or other items other than defects in items actually inspected by Qualitech and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by Qualitech and which are covered by this certificate or report.The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to Qualitech personnel. The report does not purport to list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severety ratings in the report are based on the criteria shown in this report and are intended as a guideline only. No responsability is assumed for the control or correction of conditions
Page 1 of 6
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box01-C, Anil, Jacarepaguá–RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-072B Rev.2
CERTIFICATE OF TEST AND THOROUGH EXAMINATION
Certificate Number: CTE-1153-055
Customer: Ocean Rig Color Code: Green
Location: Corcovado Inspection Procedure: ISO 2415
SFI Code: N/A Client WO: N/A
Date of Examination: 06/10/2015 Manufacture: Crosby
Date of Next Examination: 05/04/2016 Equipment Status: Ok
Identity No Description & Detail Of Equipment Location SWL Test Proof
Load
41259921 NVD- 3617 Safety Pin Bow Shackles Riser Deck 55 t N/A
General Comment: NO DEFECTS WERE FOUND AT TIME OF THE INSPECTION.
I certify on behalf of the firm, Company, association or technician named below that the items described herein were tested and thereafter examined and were found to be free from cracks, flaws or other defects
Name / Qualification:
Bruno Cerri
Signed / Stamp:
Date of Inspection:
06/10/2015
Approved by:
This certification or Report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer,manufacture, seller, supplier repairer, or operator of any warranty, express or implied and Qualitech. Liability shall be limited to the acs and omissions of it's employees, agents and subcontractors. Under no circumstances shall Qualitech be liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse of or any defect in material, machinery, equipment, or other items other than defects in items actually inspected by Qualitech and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by Qualitech and which are covered by this certificate or report.The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to Qualitech personnel. The report does not purport to list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severety ratings in the report are based on the criteria shown in this report and are intended as a guideline only. No responsability is assumed for the control or correction of conditions.
Page 2 of 6
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box01-C, Anil, Jacarepaguá–RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-072B Rev.2
CERTIFICATE OF TEST AND THOROUGH EXAMINATION
Certificate Number: CTE-1153-055
Customer: Ocean Rig Color Code: Green
Location: Corcovado Inspection Procedure: ISO 2415
SFI Code: N/A Client WO: N/A
Date of Examination: 06/10/2015 Manufacture: Global Integrated Services
Date of Next Examination: 05/04/2016 Equipment Status: Ok
Identity No Description & Detail Of Equipment Location SWL Test Proof
Load
190/1A-1D
4x Safety Pin Bow Shackles
Riser Deck 4,75 tonne N/A
General Comment: NO DEFECTS WERE FOUND AT TIME OF THE INSPECTION.
I certify on behalf of the firm, Company, association or technician named below that the items described herein were tested and thereafter examined and were found to be free from cracks, flaws or other defects
Name / Qualification:
Bruno Cerri
Signed / Stamp:
Date of Inspection:
06/10/2015
Approved by:
This certification or Report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer,manufacture, seller, supplier repairer, or operator of any warranty, express or implied and Qualitech. Liability shall be limited to the acs and omissions of it's employees, agents and subcontractors. Under no circumstances shall Qualitech be liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse of or any defect in material, machinery, equipment, or other items other than defects in items actually inspected by Qualitech and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by Qualitech and which are covered by this certificate or report.The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to Qualitech personnel. The report does not purport to list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severety ratings in the report are based on the criteria shown in this report and are intended as a guideline only. No responsability is assumed for the control or correction of conditions.
Page 3 of 6
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box01-C, Anil, Jacarepaguá–RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-072B Rev.2
CERTIFICATE OF TEST AND THOROUGH EXAMINATION
Certificate Number: CTE-1153-055
Customer: Ocean Rig Color Code: Green
Location: Corcovado Inspection Procedure: ISO 2415
SFI Code: N/A Client WO: N/A
Date of Examination: 06/10/2015 Manufacture: Global Integrated Services
Date of Next Examination: 05/04/2016 Equipment Status: Ok
Identity No Description & Detail Of Equipment Location SWL Test Proof
Load
188/1A-1D
4x Safety Pin Bow Shackles
Riser Deck 4,75 tonne N/A
General Comment: NO DEFECTS WERE FOUND AT TIME OF THE INSPECTION.
I certify on behalf of the firm, Company, association or technician named below that the items described herein were tested and thereafter examined and were found to be free from cracks, flaws or other defects
Name / Qualification:
Bruno Cerri
Signed / Stamp:
Date of Inspection:
06/10/2015
Approved by:
This certification or Report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer,manufacture, seller, supplier repairer, or operator of any warranty, express or implied and Qualitech. Liability shall be limited to the acs and omissions of it's employees, agents and subcontractors. Under no circumstances shall Qualitech be liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse of or any defect in material, machinery, equipment, or other items other than defects in items actually inspected by Qualitech and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by Qualitech and which are covered by this certificate or report.The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to Qualitech personnel. The report does not purport to list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severety ratings in the report are based on the criteria shown in this report and are intended as a guideline only. No responsability is assumed for the control or correction of conditions.
Page 4 of 6
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box01-C, Anil, Jacarepaguá–RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-072B Rev.2
CERTIFICATE OF TEST AND THOROUGH EXAMINATION
Certificate Number: CTE-1153-055
Customer: Ocean Rig Color Code: Green
Location: Corcovado Inspection Procedure: ISO 2415
SFI Code: N/A Client WO: N/A
Date of Examination: 06/10/2015 Manufacture: Global Integrated Services
Date of Next Examination: 05/04/2016 Equipment Status: Ok
Identity No Description & Detail Of Equipment Location SWL Test Proof
Load
148/1A-1D
4x Safety Pin Bow Shackles
Riser Deck 4,75 tonne N/A
General Comment: NO DEFECTS WERE FOUND AT TIME OF THE INSPECTION.
I certify on behalf of the firm, Company, association or technician named below that the items described herein were tested and thereafter examined and were found to be free from cracks, flaws or other defects
Name / Qualification:
Bruno Cerri
Signed / Stamp:
Date of Inspection:
06/10/2015
Approved by:
This certification or Report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer,manufacture, seller, supplier repairer, or operator of any warranty, express or implied and Qualitech. Liability shall be limited to the acs and omissions of it's employees, agents and subcontractors. Under no circumstances shall Qualitech be liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse of or any defect in material, machinery, equipment, or other items other than defects in items actually inspected by Qualitech and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by Qualitech and which are covered by this certificate or report.The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to Qualitech personnel. The report does not purport to list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severety ratings in the report are based on the criteria shown in this report and are intended as a guideline only. No responsability is assumed for the control or correction of conditions.
Page 5 of 6
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box01-C, Anil, Jacarepaguá–RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-072B Rev.2
CERTIFICATE OF TEST AND THOROUGH EXAMINATION
Certificate Number: CTE-1153-055
Customer: Ocean Rig Color Code: Green
Location: Corcovado Inspection Procedure: ISO 2415
SFI Code: N/A Client WO: N/A
Date of Examination: 06/10/2015 Manufacture: Global Integrated Services
Date of Next Examination: 05/04/2016 Equipment Status: Ok
Identity No Description & Detail Of Equipment Location SWL Test Proof
Load
213109/1A-1D
4x Safety Pin Bow Shackles
Riser Deck 4,75 tonne N/A
General Comment: NO DEFECTS WERE FOUND AT TIME OF THE INSPECTION.
I certify on behalf of the firm, Company, association or technician named below that the items described herein were tested and thereafter examined and were found to be free from cracks, flaws or other defects
Name / Qualification:
Bruno Cerri
Signed / Stamp:
Date of Inspection:
06/10/2015
Approved by:
This certification or Report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer,manufacture, seller, supplier repairer, or operator of any warranty, express or implied and Qualitech. Liability shall be limited to the acs and omissions of it's employees, agents and subcontractors. Under no circumstances shall Qualitech be liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse of or any defect in material, machinery, equipment, or other items other than defects in items actually inspected by Qualitech and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by Qualitech and which are covered by this certificate or report.The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to Qualitech personnel. The report does not purport to list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severety ratings in the report are based on the criteria shown in this report and are intended as a guideline only. No responsability is assumed for the control or correction of conditions.
Page 6 of 6
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box01-C, Anil, Jacarepaguá–RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-072B Rev.2
CERTIFICATE OF TEST AND THOROUGH EXAMINATION
Certificate Number: CTE-1153-055
Customer: Ocean Rig Color Code: Green
Location: Corcovado Inspection Procedure: ISO 2415
SFI Code: N/A Client WO: N/A
Date of Examination: 06/10/2015 Manufacture: Global Integrated Services
Date of Next Examination: 05/04/2016 Equipment Status: Ok
Identity No Description & Detail Of Equipment Location SWL Test Proof
Load
213092/1A-1D
4x Safety Pin Bow Shackles
Riser Deck 4,75 tonne N/A
General Comment: NO DEFECTS WERE FOUND AT TIME OF THE INSPECTION.
I certify on behalf of the firm, Company, association or technician named below that the items described herein were tested and thereafter examined and were found to be free from cracks, flaws or other defects
Name / Qualification:
Bruno Cerri
Signed / Stamp:
Date of Inspection:
06/10/2015
Approved by:
This certification or Report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer,manufacture, seller, supplier repairer, or operator of any warranty, express or implied and Qualitech. Liability shall be limited to the acs and omissions of it's employees, agents and subcontractors. Under no circumstances shall Qualitech be liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse of or any defect in material, machinery, equipment, or other items other than defects in items actually inspected by Qualitech and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by Qualitech and which are covered by this certificate or report.The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to Qualitech personnel. The report does not purport to list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severety ratings in the report are based on the criteria shown in this report and are intended as a guideline only. No responsability is assumed for the control or correction of conditions.
Page 1 of 7
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box01-C, Anil, Jacarepaguá–RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-097B Rev.4
MAGNETIC PARTICLE INSPECTION REPORT
Client: Ocean Rig Location: Corcovado (NS-40) Report Number: MPI-1173-029
P.O. Nr: Qualitech WO: 1173 Inspection Procedure: PI-QT-003 Rev.2
SFI Code: Client WO: Surface: Brushed
Equipment Description: Container (Pad Eye) Qty: 5 Size: 1110mm x 1110mm x2210mm
Serial Number: W2-13-109/W2-13-149/W2-13-188/W2-13-190/W2-13-92
Reference Drawing N°: JN 9150G
Specification: ASTM E-709 Material: Carbon Steel Manufacture: David Ritchie Equipment
Comment: Area Inspected: As per clients request a Visual and Magnetic Particle Inspection was carried out on 100% of the accessible critical area of the Container (Pad Eye). Result: No defects were found at time of inspection. Conclusion: Acceptable to the Specification. Recommendations: Authorized for use. Continuation Attached: Yes
Name / Qualification: Bruno Cerri
SNT/MT-3276
Signed / Stamp:
Date of Inspection: 24/09/2015
Approved By:
Equipment/Magnetization
Magnetization Technique
Coil
Magnetization : Longitudinal Current Flow : Alternating
Ligth Type:
x Natural Artificial
x Yoke Pull 10lbs
Yes Pole Spacing:
4” to 6 “
Ilumination:1200 lux
Flux Indicator:
Berthold x Burmah Strip
Equipment Description: MY-2 Voltage: 110V Serial No:1303093
Test Method
Test Medium Dry X Colour Wet Wet Fluorescent
Particle Type: RW222
Contrast Type: 104
Antifoaming Type: 787
Black Light Unit: N/A
FL/Sample AT:
UV:0,1 to 0,4L
Visible:0,4 to 1,2L
Batch No:
Maker: Metal Check
Maker: Metal Check
Maker: Metal Check
Model: N/A
Batch Nr: 9884
Batch Nr: 7863
Batch Nr: 8733
Serial Nr: N/A
Page 2 of 7
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box01-C, Anil, Jacarepaguá–RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-097B Rev.4
MAGNETIC PARTICLE INSPECTION REPORT
Client: Petrobras Report Number: MPI-1173-029
P.O. Nr: WO: 1173 Location: Corcovado (NS-40)
Item: Container (Pad Eye) Inspection Details: As per clients request a Visual and Magnetic Particle Inspection was carried out on 100% of the accessible critical area of the Container (Pad Eye)
Name & Qualification: Bruno Cerri
SNT/MT-3276
Signed/Stamp:
Date of Inspection: 03/10/2015
Approved By:
Page 3 of 7
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box01-C, Anil, Jacarepaguá–RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-097B Rev.4
MAGNETIC PARTICLE INSPECTION REPORT
Client: Petrobras Report Number: MPI-1173-029
P.O. Nr: WO: 1173 Location: Corcovado (NS-40)
Item: Container (Pad Eye) Inspection Details: As per clients request a Visual and Magnetic Particle Inspection was carried out on 100% of the accessible critical area of the Container (Pad Eye)
Name & Qualification: Bruno Cerri
SNT/MT-3276
Signed/Stamp:
Date of Inspection: 03/10/2015
Approved By:
Page 4 of 7
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box01-C, Anil, Jacarepaguá–RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-097B Rev.4
MAGNETIC PARTICLE INSPECTION REPORT
Client: Petrobras Report Number: MPI-1173-029
P.O. Nr: WO: 1173 Location: Corcovado (NS-40)
Item: Container (Pad Eye) Inspection Details: As per clients request a Visual and Magnetic Particle Inspection was carried out on 100% of the accessible critical area of the Container (Pad Eye)
Name & Qualification: Bruno Cerri
SNT/MT-3276
Signed/Stamp:
Date of Inspection: 03/10/2015
Approved By:
Page 5 of 7
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box01-C, Anil, Jacarepaguá–RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-097B Rev.4
MAGNETIC PARTICLE INSPECTION REPORT
Client: Petrobras Report Number: MPI-1173-029
P.O. Nr: WO: 1173 Location: Corcovado (NS-40)
Item: Container (Pad Eye) Inspection Details: As per clients request a Visual and Magnetic Particle Inspection was carried out on 100% of the accessible critical area of the Container (Pad Eye)
Name & Qualification: Bruno Cerri
SNT/MT-3276
Signed/Stamp:
Date of Inspection: 03/10/2015
Approved By:
Page 6 of 7
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box01-C, Anil, Jacarepaguá–RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-097B Rev.4
MAGNETIC PARTICLE INSPECTION REPORT
Client: Petrobras Report Number: MPI-1173-029
P.O. Nr: WO: 1173 Location: Corcovado (NS-40)
Item: Container (Pad Eye) Inspection Details: As per clients request a Visual and Magnetic Particle Inspection was carried out on 100% of the accessible critical area of the Container (Pad Eye)
Name & Qualification: Bruno Cerri
SNT/MT-3276
Signed/Stamp:
Date of Inspection: 03/10/2015
Approved By:
Page 7 of 7
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box01-C, Anil, Jacarepaguá–RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-097B Rev.4
MAGNETIC PARTICLE INSPECTION REPORT
Client: Petrobras Report Number: MPI-1173-029
P.O. Nr: WO: 1173 Location: Corcovado (NS-40)
Item: Container (Pad Eye) Inspection Details: As per clients request a Visual and Magnetic Particle Inspection was carried out on 100% of the accessible critical area of the Container (Pad Eye)
Name & Qualification: Bruno Cerri
SNT/MT-3276
Signed/Stamp:
Date of Inspection: 03/10/2015
Approved By:
Page 1 of 1
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box01-C, Anil, Jacarepaguá–RJ – Brasil CEP 22765-240 www.qualitechirm.com
Quality for safety RP-QT-117B Rev.2
PHOTOGRAPHIC INSPECTION REPORT
Client: Ocean Rig WO: 1173 Report Number: PIR-1173-012
P.O. Nr: N/A Client PMS Number: N/A Location: Corcovado
Item: High Pressure Water
Details: Made Visual Inspection in the Pipe Leaking
Corrective Action: Was Changed Pipe
Name / Qualification: Bruno Cerri
Signed / Stamp:
Date of Inspection: 10/10/2015
Approved by:
Sr. Allan Paulino Siqueira Mr. Allan Paulino Siqueira
Certificado Nº. ET - 4322 R1
Certificate Nr. ET - 4322 R1
É qualificado como Nível II no ensaio de Correntes Parasitas de acordo com os requisitos da Pratica Escrita da Qualitech PI QT 10 Rev.1 baseado na Prática Recomendada SNT-TC 1A (Ed. 2006) da ASNT.
Is qualified as Level II in Eddy Current testing according to the requirements of Qualitech
Written Practice PI QT 10 Rev. 1 based in recommended practice SNT-TC-1A (2006 edition) of ASNT.
Data da Certificação: 01 de Fevereiro 2013(IRM) Certification Date: Fevereiro 01st 2013 (IRM)
Recertificado em: Outubro de 2014 (R1) Recertificated in: October 2014 (R1)
Validade: Outubro de 2018 Validity: October 2018
Transferido para Qualitech em: Outubro de 2014
Transferred to Qualitech in: October 2014
_________________________ _________________________ Marco Antonio M. de Guido Leonardo Torres
Nível III ASNT nº. 85594 Qualitech Inspeção, Reparo e Manutenção Ltda.
Este certificado é válido por um período de cinco anos contados à partir da data acima, salvo cancelamento ou revogação em data anterior e perderá sua validade quando o nomeado deixar de ser funcionário da Qualitech Inspeção, Reparo e Manutenção Ltda.
This certificate is valid for a period of five years from the above date of signature, unless terminated or revoked at an earlier data, and it is automatically terminated when the above named ceases to be an employee of Qualitech Inspeção, Reparo e Manutenção Ltda.
Sr. Allan Paulino Siqueira Mr. Allan Paulino Siqueira
Certificado Nº. MT - 3001 R1
Certificate Nr. MT - 3001 R1
É qualificado como Nível II no ensaio de Partículas Magnéticas de acordo com os requisitos da Pratica Escrita da Qualitech PI QT 10 Rev.1 baseado na Prática Recomendada SNT-TC 1A (Ed. 2006) da ASNT.
Is qualified as Level II in Magnetic Particle testing according to the requirements of Qualitech
Written Practice PI QT 10 Rev. 1 based in recommended practice SNT-TC-1A (2006 edition) of ASNT.
Data da Certificação: 08 de Outubro 2010(IRM) Certification Date: October 08th 2010(IRM)
Recertificado em: Outubro de 2014 (R1) Recertificated in: October 2014 (R1)
Validade: Outubro de 2016 Validity: October 2016
Transferido para Qualitech em: Outubro de 2014
Transferred to Qualitech in: October 2014
_________________________ _________________________ Marco Antonio M. de Guido Leonardo Torres
Nível III ASNT nº. 85594 Qualitech Inspeção, Reparo e Manutenção Ltda.
Este certificado é válido por um período de cinco anos contados à partir da data acima, salvo cancelamento ou revogação em data anterior e perderá sua validade quando o nomeado deixar de ser funcionário da Qualitech Inspeção, Reparo e Manutenção Ltda.
This certificate is valid for a period of five years from the above date of signature, unless terminated or revoked at an earlier data, and it is automatically terminated when the above named ceases to be an employee of Qualitech Inspeção, Reparo e Manutenção Ltda.
Sr. Allan Paulino Siqueira Mr. Allan Paulino Siqueira
Certificado Nº. UT - 3267 ME
Certificate Nr. UT - 3267 R1 ME
É qualificado como Nível II no ensaio de Ultrasson / Medição de Espessura de acordo com os requisitos da Pratica Escrita da Qualitech PI QT 10 Rev.1 baseado na Prática Recomendada SNT-TC 1A (Ed. 2006) da ASNT.
Is qualified as Level II in Ultrasonic / Thickness Measure testing according to the requirements of Qualitech
Written Practice PI QT 10 Rev. 1 based in recommended practice SNT-TC-1A (2006 edition) of ASNT.
Data da Certificação: 24 de Maio 2011(IRM) Certification Date: May 24th 2010(IRM)
Recertificado em: Outubro de 2014 (R1) Recertificated in: October 2014 (R1)
Validade: Maio de 2016 Validity: May 2016
Transferido para Qualitech em: Outubro de 2014
Transferred to Qualitech in: October 2014
_________________________ _________________________ Marco Antonio M. de Guido Leonardo Torres
Nível III ASNT nº. 85594 Qualitech Inspeção, Reparo e Manutenção Ltda.
Este certificado é válido por um período de cinco anos contados à partir da data acima, salvo cancelamento ou revogação em data anterior e perderá sua validade quando o nomeado deixar de ser funcionário da Qualitech Inspeção, Reparo e Manutenção Ltda.
This certificate is valid for a period of five years from the above date of signature, unless terminated or revoked at an earlier data, and it is automatically terminated when the above named ceases to be an employee of Qualitech Inspeção, Reparo e Manutenção Ltda.
REGISTRO 36224/2015
Certificamos que Allan Paulino Siqueira participou do Treinamento deAtendimento a NR-34 Item 4 - Curso básico para Trabalhos a Quente -Módulo Geral - nas instalações da QUALITECH INSPEÇÃO, REPAROE MANUTENÇÃO LTDA, no dia 30 de Junho de 2015, carga horária08h.
___________________________Leonardo Torres Martins da SilvaDiretor de OperaçõesCNPJ:17.417.147/0001-84
__________________________________Antônio Carlos Dias PereiraCREA-RJ:1999105764CNPJ:10.848.080/0001-93
RP-QT-086 Rev.0
Rio de Janeiro, 30 de Junho de 2015.Validade: 12 meses
Estudo da NR-34, Item 34.5;b) Identificação de Perigos e Análise de Riscos• Conceitos de Perigos e Riscos;• Técnicas de Identificação de Perigos e Análise de Riscos;• APP e APR - Análise Preliminar de Perigos e Análise Preliminar de Riscos. c)Permissão para Trabalho - PT; d) Limite inferior e superior de explosividade; e) Medidas de Controle no Local de Trabalho • Inspeção Preliminar• Controle de materiais combustíveis e inflamáveis• Proteção Física• Atividades no entorno• Sinalização e Isolamento do Local de Trabalho;• Inspeção Posterior para controle de fontes de igniçãof) Renovação de Ar no Local de Trabalho (Ventilação/Exaustão);g) Rede de Gases (Válvulas e Engates); h) Ergonomia;i) Doenças ocupacionais;ii) j) FISPQ
RP-QT-066 Rev.0
Certificamos que Allan Paulino Siqueira participou do Treinamento deAtendimento a NR-34 Condições e Meio Ambiente de Trabalho naIndústria de Construção e Reparação Naval nas instalações daQUALITECH INSPEÇÃO, REPARO E MANUTENÇÃO LTDA, nodia 22 de setembro de 2015, carga horária 06h.
___________________________Leonardo Torres Martins da SilvaDiretor de OperaçõesCNPJ:17.417.147/0001-84
__________________________________Antônio Carlos Dias PereiraCREA-RJ:1999105764CNPJ:10.848.080/0001-93
RP-QT-086 Rev.0
Rio de Janeiro, 22 de setembro de 2015.Validade: 12 meses
Riscos Inerentes as Atividades:− Divulgação dos Riscos Ocupacionais existentes em cada atividade e suas medidas de controle,Divulgação da Ordem de Serviço conforme NR-01.
Uso adequado de Equipamentos de Proteção Individual – EPI e Equipamento de Proteção ColetivaEPC existentes no estabelecimento:− Movimentação de Carga, equipamentos e acessórios, uso e operacionalidade.− Definição de EPI, Obrigatoriedades quanto ao uso dos mesmos conforme NR-06, Uso correto deEPI’s com exercício prático para Proteção de Cabeça, Tronco; Membros Inferiores e Superiores; Mãos;Pés; Olhos; Facial; Respiratória e Auditiva;− Guarda e higienização dos EPI´s;− Definição de EPC,Informações sobre os tipos de EPC´s existentes nas atividades da Empresa e emUnidades de Contratos e informações sobre o manuseio dos mesmos.
Condições e meio ambiente de trabalho:− Informações sobre Unidades de Contrato;− Regras de Segurança, Saúde e Meio Ambiente para as Atividades Operacionais;− Informações sobre sistemas para Identificação de Riscos e Reconhecimento de Boas Práticas de nossos clientes com exercício prático.
RP-QT-066 Rev.0
Sr. Bruno da Silveira Cerri Mr. Bruno da Silveira Cerri
Certificado Nº. MT - 3276
Certificate Nr. MT - 3276
É qualificado como Nível II no ensaio de Partículas Magnéticas de acordo com os requisitos da Pratica Escrita da Qualitech PI QT 10 Rev.0 baseado na Prática Recomendada SNT-TC 1A (Ed. 2006) da ASNT.
Is qualified as Level II in Magnetic Particle testing according to the requirements of Qualitech
Written Practice PI QT 10 Rev. 0 based in recommended practice SNT-TC-1A (2006 edition) of ASNT.
Data da Certificação: 24 de Maio de 2011 (IRM) Certification Date: May 24th 2011 (IRM)
Validade: Julho de 2018 Validity: July 2018
Transferido para Qualitech em: Julho de 2014
Transferred to Qualitech in: Julho 2014
_________________________ _________________________ Marco Antonio M. de Guido Leonardo Torres
Nível III ASNT nº. 85594 Qualitech Inspeção, Reparo e Manutenção Ltda.
Este certificado é válido por um período de cinco anos contados à partir da data acima, salvo cancelamento ou revogação em data anterior e perderá sua validade quando o nomeado deixar de ser funcionário da Qualitech Inspeção, Reparo e Manutenção Ltda.
This certificate is valid for a period of five years from the above date of signature, unless terminated or revoked at an earlier data, and it is automatically terminated when the above named ceases to be an employee of Qualitech Inspeção, Reparo e Manutenção Ltda.
Sr. Bruno da Silveira Cerri Mr. Bruno da Silveira Cerri
Certificado Nº. UT - 3269
Certificate Nr. UT - 3269
É qualificado como Nível II no ensaio de Ultrassom / Medição de Espessura de acordo com os requisitos da Pratica Escrita da Qualitech PI QT 10 Rev.0 baseado na Prática Recomendada SNT-TC 1A (Ed. 2006) da ASNT.
Is qualified as Level II in Ultrasonic / Thickness Measure testing according to the requirements of Qualitech
Written Practice PI QT 10 Rev. 0 based in recommended practice SNT-TC-1A (2006 edition) of ASNT.
Data da Certificação: 24 de Maio de 2011 (IRM) Certification Date: May 24th 2011 (IRM)
Validade: Maio de 2016 Validity: May 2016
Transferido para Qualitech em: Julho de 2014
Transferred to Qualitech in: Julho 2014
_________________________ _________________________ Marco Antonio M. de Guido Leonardo Torres
Nível III ASNT nº. 85594 Qualitech Inspeção, Reparo e Manutenção Ltda.
Este certificado é válido por um período de cinco anos contados à partir da data acima, salvo cancelamento ou revogação em data anterior e perderá sua validade quando o nomeado deixar de ser funcionário da Qualitech Inspeção, Reparo e Manutenção Ltda.
This certificate is valid for a period of five years from the above date of signature, unless terminated or revoked at an earlier data, and it is automatically terminated when the above named ceases to be an employee of Qualitech Inspeção, Reparo e Manutenção Ltda.
Certificamos que Bruno da Silveira Cerri participou do Treinamento deAtendimento a NR-34 Condições e Meio Ambiente de Trabalho naIndústria de Construção e Reparação Naval nas instalações daQUALITECH INSPEÇÃO, REPARO E MANUTENÇÃO LTDA, nodia 02 de Julho de 2015, carga horária 06h.
___________________________Leonardo Torres Martins da SilvaDiretor de OperaçõesCNPJ:17.417.147/0001-84
__________________________________Antônio Carlos Dias PereiraCREA-RJ:1999105764CNPJ:10.848.080/0001-93
RP-QT-086 Rev.0
Rio de Janeiro, 02 de Julho de 2015.Validade: 12 meses
Riscos Inerentes as Atividades:− Divulgação dos Riscos Ocupacionais existentes em cada atividade e suas medidas de controle,Divulgação da Ordem de Serviço conforme NR-01.
Uso adequado de Equipamentos de Proteção Individual – EPI e Equipamento de Proteção ColetivaEPC existentes no estabelecimento:− Movimentação de Carga, equipamentos e acessórios, uso e operacionalidade.− Definição de EPI, Obrigatoriedades quanto ao uso dos mesmos conforme NR-06, Uso correto deEPI’s com exercício prático para Proteção de Cabeça, Tronco; Membros Inferiores e Superiores; Mãos;Pés; Olhos; Facial; Respiratória e Auditiva;− Guarda e higienização dos EPI´s;− Definição de EPC,Informações sobre os tipos de EPC´s existentes nas atividades da Empresa e emUnidades de Contratos e informações sobre o manuseio dos mesmos.
Condições e meio ambiente de trabalho:− Informações sobre Unidades de Contrato;− Regras de Segurança, Saúde e Meio Ambiente para as Atividades Operacionais;− Informações sobre sistemas para Identificação de Riscos e Reconhecimento de Boas Práticas de nossos clientes com exercício prático.
RP-QT-066 Rev.0
REGISTRO 40394/2015
Certificamos que Rennan Gaspar Mendes participou do Treinamentode Atendimento a NR-34 Condições e Meio Ambiente de Trabalho naIndústria de Construção e Reparação Naval nas instalações daQUALITECH INSPEÇÃO, REPARO E MANUTENÇÃO LTDA, nodia 27de Março de 2015, carga horária 06h.
___________________________Leonardo Torres Martins da SilvaDiretor de OperaçõesCNPJ:17.417.147/0001-84
__________________________________Antônio Carlos Dias PereiraCREA-RJ:1999105764CNPJ:10.848.080/0001-93
RP-QT-086 Rev.0
Rio de Janeiro, 27 de Março de 2015.Validade: 12 meses
Riscos Inerentes as Atividades:− Divulgação dos Riscos Ocupacionais existentes em cada atividade e suas medidas de controle,Divulgação da Ordem de Serviço conforme NR-01.
Uso adequado de Equipamentos de Proteção Individual – EPI e Equipamento de Proteção ColetivaEPC existentes no estabelecimento:− Movimentação de Carga, equipamentos e acessórios, uso e operacionalidade.− Definição de EPI, Obrigatoriedades quanto ao uso dos mesmos conforme NR-06, Uso correto deEPI’s com exercício prático para Proteção de Cabeça, Tronco; Membros Inferiores e Superiores; Mãos;Pés; Olhos; Facial; Respiratória e Auditiva;− Guarda e higienização dos EPI´s;− Definição de EPC,Informações sobre os tipos de EPC´s existentes nas atividades da Empresa e emUnidades de Contratos e informações sobre o manuseio dos mesmos.
Condições e meio ambiente de trabalho:− Informações sobre Unidades de Contrato;− Regras de Segurança, Saúde e Meio Ambiente para as Atividades Operacionais;− Informações sobre sistemas para Identificação de Riscos e Reconhecimento de Boas Práticas de nossos clientes com exercício prático.
RP-QT-066 Rev.0