POWERED-AIR PURIFYING RESPIRATOR
(PAPR)Refresher Training
Learning Objectives next
previous
Slide 2 of 22
At the end of the
training, you will be
able to:
What is a PAPR?next
previous
Slide 3 of 22
A Powered-Air Purifying Respirator (PAPR) is a high efficiency powered air blower/filtration unit that consists of motor-driven fan and battery pack.
The fan draws contaminated air through the high efficiency filter before it enters the breathing tube in the rear of the headgear.
Capabilities of a PAPRnext
previous
Slide 4 of 22
Inertial Impaction - particles having too much inertia due to size or mass cannot follow the airstream as it is diverted around a filter fiber. This mechanism is responsible for collecting larger particles.
Interception - As particles pass close to a filter fiber, they may be intercepted by the fiber. Again, this mechanism is responsible for collecting larger particles.
Diffusion - Small particles are constantly bombarded by air molecules, which causes them to deviate from the airstream and come into contact with a filter fiber. This mechanism is responsible for collecting smaller particles.
Electrostatic Attraction - Oppositely charged particles are attracted to a charged fiber. This collection mechanism does not favor a certain particle size.
from NIOSH - Guidance for Protecting Building Environments from Airborne Chemical, Biological, or Radiological Attacks
Capabilities of a PAPRnext
previous
Slide 5 of 22from NIOSH - Guidance for Protecting Building Environments from Airborne
Chemical, Biological, or Radiological Attacks
Respiratory Protection against certain airborne particulate contaminants, including dusts, fumes, mists, and radionuclides.
Impaction and interception are the dominant collection mechanisms for particles greater than 0.2 µm, and diffusion is dominant for particles less than 0.2 µm.
Capabilities of a PAPRnext
previous
Slide 6 of 22
from OSHA – Assigned Protection Factors for the Revised Respiratory Protection Standard
The assigned protection factors (APF) for a loose-fitting face piece and a hood is 25. This means that the respirator offers protection against the contaminate at 25 times its Permissible Exposure Limit (PEL). The hooded PAPR can have an APF of 1000 if the respirator manufacturer can provide evidence that testing of the PAPR with the hood demonstrates performance at a level of protection of 1,000 or greater.
Limitations of a PAPRnext
previous
Slide 7 of 22
Do NOT use if:
– Atmospheres contain less than 19.5% oxygen
– Atmospheres presents an immediate dangerous to life or health condition
– Airflow of PAPR is less than 6 cfm
– Concentration of contaminants are unknown
– Toxic gases or vapors are present
– Any parts of PAPR are damaged
Why do you need a PAPR? next
previous
Slide 8 of 22
To Protect Yourself from Potential Exposure to Respiratory Pathogens and Particulates
• Tuberculosis (TB)• Select Agents
Avian Influenza Francisella tularensis Yersinia Pestis
• Aerosolization of Pathogens Flow Cytometry Sonication
• Animal Dander/Shedding
Picture from Belgian Biosafety Server
Pipetting generates aerosols.
When do you need a PAPR?next
previous
Slide 9 of 22
• Entering any BSL3 or ABSL3 facilities
• Entering ABSL2 facilities if a N95 respirator is not sufficient
• Working in the Cell Sorting Facility with live BSL2 agents upon Biosafety Officer’s requirements
• Any tuberculosis research that involves or has the potential for aerosol formation
• Any task utilizing select agents
Who says you need a PAPR?next
previous
Slide 10 of 22
• The use of feasible engineering controls is the primary means to control air contaminants.
• Respirators are required when “effective engineering controls are not feasible, or while they are being instituted.”
• In some cases, where the hazard cannot be completely eliminated, and thus requires the use of a respirator.
Occupational Safety & Health Administration (OSHA) says…
OSHA Respiratory Protection Standardnext
previous
Slide 11 of 22
29 CFR 1920.134
Requires:• Written Program and SOPs
– Describes procedures for routine use– Describes procedures for emergency situations
• Medical Evaluation• Annual Training• Annual Fit Testing
– Not required for PAPR Use
How do you use a PAPR?next
previous
Slide 12 of 22
PAPR must always be inspected prior to donning and entering contaminated area.
Check hood for tears, rips, blistering, and discoloration of the material. For loose-fitting face pieces also check elasticity around the edges.
Check for creases and cracks in the face shield.
Check the hose for tears, pinholes, and blistering of material.
Check the green LED light on the battery. If the light is on when the battery is not plugged into the respirator, the battery is receiving power from the outlet. If the light is on when the battery is plugged into the respirator, the respirator should be fully charged (6 cfm for 8 hours).
Check the belt for damage.
Use the airflow indicator to ensure ample air and charge. Should be above top line.
Check motor unit for cracks and damage.
Putting on a PAPRnext
previous
Slide 13 of 22
Click the picture above to view the video
Taking off your PAPRnext
previous
Slide 14 of 22
Click the picture above to view the video
What if my PAPR stops working?next
previous
Slide 15 of 22
1. Close all cultures, and leave everything in the biological safety cabinet.
2. Exit the lab as usual.
3. Notify your supervisor, facility manager, or respirator coordinator.
4. Get new personal protective equipment and respirator.
How do I maintain my PAPR?next
previous
Slide 16 of 22
• Decontaminate the PAPR with a non-alcoholic, non-abrasive cleaner.
• Inspect the hood, hose, and PAPR unit for any damage.
• Hoods and hoses must be replaced 6 months after their initial use.
• Batteries are replaced every two years. • Filters and gaskets must be replaced
annually.– They must be changed inside a certified
biosafety cabinet inside containment, and under the watch of the respirator coordinator, facility manager or Biosafety Officer.
gasket
PAPR Unit Interior
How do I maintain my PAPR?next
previous
Slide 17 of 22
The PAPR or PAPR parts should be replaced if the following conditions are present:
– If required by infection control procedures.
– If required by research protocols and/or procedures.
– If there is noticeable damage to the respirator.
– If the filter media of the respirator becomes wet or moist.
– If the respirator has become contaminated with blood or body fluids, and cannot adequately be decontaminated.
How do I dispose of old PAPR parts?next
previous
Slide 18 of 22
• All old, replaced, nonoperational, or damaged PAPRs or PAPR parts must be decontaminated prior to disposal. – All PAPR parts (i.e. hoods, hoses, and filters) must be autoclaved
prior to disposal. – After decontamination, items must be disposed of as medical waste.
How do I store my PAPR?next
previous
Slide 19 of 22
• Return the PAPR to the charging station– Batteries can be left on trickle charge for 30 consecutive days.
Longer periods of time may cause batteries to lose their capacity to hold a charge.
• Complete the respirator log book– when changing the filters and gaskets. Respirator use must be
recorded on sign in logs for daily use
• Store the hood and hose in a clean, dry area away from heat and direct sunlight– Ensure hood and hose are completely dry before storage
User Responsibilitiesnext
previous
Slide 20 of 22
• Respirator should be inspected before and after each use.
• Inform your facility manager of any defects or improper PAPR function.
• The headpiece of the PAPR should be replaced every 6 months or when the hood begins to breakdown, which ever comes first.
• The respirator HEPA filter and gasket must be replaced every 12 months.
• PAPR batteries must be recharged after each use.
• After every use of the PAPR, the user must clean off the hood, breathing tube, and battery pack with disinfectant.
• Depending on your facility’s Respiratory Protection Plan, the facility manager or each user is responsible for maintaining a record for each PAPR which lists and documents maintenance and use history.
Respiratory Protection Coordinators next
previous
Slide 21 of 22
Medical Science Building (MSB) - A900
International Center for Public Health (ICPH) &Regional Bio-containment Laboratories (RBL)
Users who do not have a respirator coordinator are responsible for the maintenance of their own respirators.
CONTACT LOCATION
Marilyn Ekonomidis BSL3 Manager
CONTACT LOCATION
Steve Park (A)BSL3 Manager and RBL 2nd Floor BSL3 Supervisor
Juanita Vakerich ABSL3 Supervisor
Blas Perez-Peixoto ICPH 2nd Floor BSL3 Supervisor
Bill Honnen ICPH 3rd Floor BSL3 Supervisor
EOHSS Contacts
previous
Slide 22 of 22
If you have any questions or need assistance, please contact us.