7
CIRCUIT BREAKER Aryam Australia Group www.aryamenergy.com | Email: [email protected] | Phone: 1300 347 922

CIRCUIT BREAKER - Znergy

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: CIRCUIT BREAKER - Znergy

CIRCUIT BREAKER

Aryam Australia Groupwww.aryamenergy.com | Email: [email protected] | Phone: 1300 347 922

Page 2: CIRCUIT BREAKER - Znergy

Circuit Protection Products at Timelec

Type Specification

OB

r T'-3----Case GradeDesign Serial Number

�-------Copmany Code

Technological Superiority

Pantents owned

No. Appl.No.

1 201530162638.3

2 201530092998.8

3 201520208773.9

4 201510136560.4

5 201520175098.4

6 PCT/CN2014/094922

Subject

Circuit break arc extinguishing system

Circuit breaker

A ciruit breaker

A residual-current circuit breaker and its tripping meachanism

A residual-current circuit breaker and its tripping meachanism

Circuit breaker operating mechanism

7 201520252191.0 A residual-current circuit breaker and its leakage current test mechanism

8 201520318294.2 A ciruit breaker

9 201410641431.6 Circuit break operating mechanism

10 201420677025.0 Circuit break arc extinguishing system

11 201420677056.6 Circuit breaker

12 201430446462. 7 Circuit breaker

-01-

Type

Patent for invention

Design patent

Utility model patent

Patent for invention

Utility model patent

PCT Application

Utility model patent

Utility model patent

Patent for invention

Utility model patent

Utility model patent

Design patent

Product Structure 0B18-63 Miniature Circuit Breaker

...

• 0

C-� e

.......

6.ill<S>: .!!',1:l

D Standards:IEC60898-1 D Pole: 1,2,3,4 D Trpping Characteristic:B,C,D D Rated Breaking Capacity(lcu):6KA, 1 OKA D Rated Current(ln):1-63A D Rated Voltage(Un/AC):240/415V D Frequency(Hz):50-60Hz D Mechanical Endurance: 20,000 D Protection Degree:IP20 • Ambient TemperatureD Operating Temperature "C: -25- +40°C D Storage Temperature °C: -25-+70°C D Terminal Size(mm2):1-16 D Tightening Torque(N.m):2.5

Hole in the bottom of terminal block D Make connection solid and reliable

0

�-

D Insulated covering designed to make great insulation protection.avoid terminal block heat due to poor contact and product damage

0

,&...J

I

0

{ Superiority

D Isolating function D IP20 full protection

-

I '*

D Handle maintains ON/O FF position by itself D Fit for PIN/Furcation type bus bar connection DON/OFF status clear indicate in REDIG REEN D DIN-Rail temporary lock.easier for installation D Easy link-up of different auxiliary contacts. releases etc

Matching Hole D Elegant Appearance D Easily Removable

-02-

Exclusive inventon patent design D Great resistance D Innovative designed, flexible

and safer D DIN-rail temporary hold,easier

for installation and disassembly

Page 3: CIRCUIT BREAKER - Znergy

Product Structure 0B18-32 Miniature Circuit Breaker

D Standards:IEC60898-1 D Pole:1+N

D Trpping Characteristic:B,C,D D Rated Breaking Capacity(lcu):4.5KA

D Rated Current(ln):1-63A

D Rated Voltage(Un/AC):240/415V D Frequency(Hz):50-60Hz

D Mechanical Endurance: 20,000

D Protection Degree:IP20

• Ambient Temperature

D Operating Temperature °C: -25-+40°C

D Storage Temperature °C: -25-+70°

C

D Terminal Size(mm2):1-1 O

D Tightening Torque(N .m): 1.2

Terminal D Tunnel type

D Tighter connection

�·

..

e C-�

0

J l

0

. ' •

0

f_,

Superiority

D Isolating function

D IP20 full protection

-

D Handle maintains ON/O FF position by itself D Fit for PIN/Furcation type busbar connection

DON/OFF status clear indicate in REDIG REEN

D DIN-Rail temporary lock.easier for installation

D Easy link-up of different auxiliary contacts. releases etc

Clear Indicator of"ON/OFF"

Indicating in red/green

Transparent Window

Designed to carry label

Handle maintains ON/OFF position by itself

J

.J

-03-

Product Structure OB18L-50 Electronic RCBO

D Standards:IEC61009-1 D Pole:1+N

D Trpping Characteristic:B,C,D

D Tripping Type: Electronic D Rated Breaking Capacity(lcu):6KA, 1 OKA

D Rated Current(ln):6-50A D Rated Voltage(Un/AC):240V

D Rated Current Characteristic: AC,A

D Rated Residual Operating Current(llin):

0.03A,0.1A,0.3A

D Frequency(Hz):50-60Hz

D Mechanical Endurance: 20,000

D Protection Degree:IP20

• Ambient Temperature

D Operating Temperature °C: -25- +40°

CD Storage Temperature °C: -25-+70

°

C

D Terminal Size(mm2):

1-16(Line side), 1-1 0(Line side)

D Tightening Torque(N.m):2.5(Line side) 1.5(Line side)

Terminal

D Tunnel type

D Tighter connection

--

�( C

0

#

0

0

Superiority

D "L+N" Product

D Isolating function

D IP20 full protection

'

·�

D Handle maintains ON/O FF position by itself

D Fit for PIN/Furcation type bus bar connection DON/OFF status clear indicate in REDIG REEN

D DIN-Rail temporary lock.easier for installation

D Easy link-up of different auxiliary contacts. releases etc

D RCBO in eludes electtronic type and over-voltage electronic type.

D Breaking capacity has strengthened to 1 OKA.

D 300mA, 1 00mA and 300mA RCBOs are suitable for

different requirements.

>

)

'

)

' Clear Indicator of "ON/OFF"

D Indicating in red/green

Transparent Window D Designed to carry label

Handle maintains ON/OFF

position by itself

-04-

Page 4: CIRCUIT BREAKER - Znergy

Product Structure OL 18-63 Electronic RCCB

D Standards:IEC61008-1

D Pole:1+N,3+N

PU$HTO OL18·63

��s; � 30mAl:il230V

D Tripping Type: Electronic-Magnetic

D Rated Breaking Capacity(lcu):6KA, 1 OKA

D Rated Current(ln):25A,40A,63A,80A

D Rated Voltage(Un/AC):240V/415V

D Rated Current Characteristic: AC,A,S

D Rated Residual Operating Current(lt.n):

0.03A,0.1A,0.3A

D Frequency(Hz):50-60Hz

D Mechanical Endurance: 4,000

D Protection Degree:IP20

• Ambient Temperature

D Operating Temperature °C: -25-+40°C

D Storage Temperature "C: -25-+ 70°C

D Terminal Size(mm2):1-25

D Tightening Torque(N.m):2.5

Test Button

D Test switch performance on a regular basis

PUSH TO OL 18-63 TEST

Sealing Plug

63A �

30mAEe123ov

D Elegant appearance

D Prevents unwanted or casual

dismounting of product

I

,

Superiority

D Clear indication of operation status

D Clear indication of leakage status

D Fit for PIN/Furcation type busbar connection

D IP20 full protection

D DIN-Rail temporary lock,easier for installation D Isolating function

D Handle maintains ON/OFF position by itself

D High impact resistance

D Electromagnetic type RCCB,completely in compliance

withGB16916.1,IEC61008-1 Standard

D Got SE MOK certificate.

D 30mA, 1 00mA,and 300mA specification are availble for

choice. D When leakage occurs,indicating window would be in red.

Din-Rail Temporary Hold D Easier for inistallation and

disaseembly

-05-

Product Structure 0D18-125 Isolator

D Standards:IEC60947-3

D Pole: 1,2,3,4

D Rated Breaking Capacity(lcu):6KA, 1 OKA

D Rated Current(ln):63A, 1 00A, 125A

0 Rated Voltage(Un/AC):240V/415V

D Frequency(Hz):50-60Hz D Mechanical Endurance: 20,000

D Protection Degree:IP20

• Ambient Temperature

D Operating Temperature "C: -25-+40°

C

D Storage Temperature "C: -25-+70°

C

D Terminal Size(mm2):16-50

D Tightening Torque(N.m):2.5

Operating Status Window Clear indication of contacting status

Superiority

D Rated current 63A, 1 00A, 125A

D Isolating function

D Clear indication of contacting status

D Fit for PIN/Furcation type busbar connection

D IP20 full protection D DIN-Rail temporary lock,easier for installation

D Handle maintains ON/OFF position by itself

D Quick acting mechanism exetends electrical endurance

-06-

Page 5: CIRCUIT BREAKER - Znergy

Distribution Box

l

Easy installation

Height of the distribution box can be adjusted

automatically at the insyallation depth within

a certain range from the extertor wall.

Dimensions

f-@ @

/ , i

"" T T

n

• :�:1. ,t • ... • � .. .. • - •• • ·�k:=l'r.., •)'-; -'!'"; "'

JJI!• !llltltlli)ig

w

4way 125

8way 197

10way 233

14way 305

16way 341

18way 377

22way 449

-07-

Unique optimized design

Superiority

4,6,8, 10, 14, 16, 18,22 ways

Much space.easier for wiring

High impact resistance material

Stylish appearance with white cover

Beautiful appearance

W1 H H1 D

75 235 170 110

132 235 170 110

168 235 170 110

240 235 170 110

276 235 170 110

312 235 170 110

384 235 170 110

Technical Data-MCB Series

IEC60898,GB 10963 Tripping Characteristic Curve(B,C,D)

10000 5000

1h 2000 1000 500 200 100 50 20

t( S) 1�

1 0.5 0.2 0.1

0.05 0.02 0.01

0.005 0.002 0.001

I I

'

'\.

'

10000 5000

1h 2000 1000 500 200 100 50 20

t( S) 1�

1 0.5 0.2 0.1

0.05 0.02 0.01

0.005 0.002 0.001

I I I I \

\

I'\ '

10000 5000

1h 2000 1000 500 200 100 50 20

t( S) 1�

1 0.5 0.2 0.1

0.05 0.02 0.01

0.005 0.002 0.001

I I I

\ \

'

r-,

-

0.5 1 2 34 57 10 20 30 5070100 0.5 1 2 3 4 5 7 10 20 30 5070 100 0.5 1 2 34 57 10 20 30 5070100

I/In I/In 1/1 n B curve C curve D curve

Electrical Specification AC Tripping Characteristics

Rated Voltage(S0Hz) 240/415V AC

Rated Current 1-63A

Thermal And Magnetic Tripping AC 50Hz-60Hz

Characteristics

Characteristic Curve At 30'C 8:3-Sln C:5-10In D:10-20In B C D

Breaking Capacity 6kA,10kA IEC60898-1 1 lth1 1.13In 1.13In 1.13In

2 lth2 1.45In 1.45In 1.45In Isolation Voltage S00V AC

3 lm1 3In Sin 10In

Mechanical Endurance 20.000 4 lm2 Sin 10In 20In

Temperature Compensation Modified Coefficient Multipolar Assembling Modified Coefficient

Rated n K

Current 30'C 35'C 40'C 45'C S0'C ss·c 60'C (A)

n=1 1

2�n<4 0.95 1 1 0.95 0.9 0.8 0.7 0.6 0.5

2 2 1.9 1.7 1.6 1.5 1.4 1.3 4�n<6 0.9

3 3 2.8 2.5 2.4 2.3 2.1 1.9 6�n 0.85

4 4 3.7 3.5 3.3 3 2.8 2.5

6 6 5.6 5.3 5 4.6 4.2 3.8

10 10 9.4 8. 8 7.5 7 6.4 Frequency 16 16 15 14 3 12 11 10

20 20 18.5 17.5 16.5 15 14 13 Overload tripping frequency-,

25 25 23.5 22 20.5 19 17.5 16 shotr-circuit protection tripping frequency-

32 32 30 28 26 24 22 20 F(Hz) 16Hz-60Hz 100Hz 200Hz 400Hz

40 40 37.5 35 33 30 28 25 k 1.1 1.2 1.5

50 50 47 44 41 38 35 32

63 63 59 55 51 48 44 40

-08-

Page 6: CIRCUIT BREAKER - Znergy

Technical Data OB18-63 l0KA MCB

• • •

1_ 0818-13

m ��� :�:.. 1: -

I

Description With protective tripping character and isolating function, 1 OKA MCB series are suitable for housing distribution system.

Superiority Matching hold for auxiliary installation

Connection Capacity Hard Wire: 16mm2

Flexible Wire: 1 0mm2

Technical Data D Conforming Standards:IEC60898-1 GB10963.1 D Breaking Capacity: 1 O,00OA D Rated Voltage:240V AC D Rated Currentl:1-63A D Mechanical Endurance:20,000 D Ambient Temperature:-25°C-40°C

Rated Current(A) Width/Module Package Quantity/Box

1-63 1

Contacting Status Indication Red:Contacting Green:Disconnecting I>

12

C

Technical Data OB18-32 4.SKA 'L+N' MCB

Description

0818-32

sa��

r��. 1:

. • •

m - -

When fault current occurs, 'L+N' MCB product disconnect phase line and neutral line at the same time. With isolating function, 'L+N' MCB applyed in housing distribution system.

Superiority Matching hold for auxiliary installation

Connection Capacity Hard Wire: 16mm2

Flexible Wire: 1 0mm2

Technical Data D Conforming Standards:IEC60898-1 GB10963.1 D Breaking Capacity:4500A D Rated Voltage:240V AC D Rated Currentl:1-32A D Mechanical Endurance:20,000 D Ambient Temperature:-25"C-40°C

Rated Current(A) Width/Module Package Quantity/Box

1-32 1

Contacting Status Indication Red:Contacting Green: Disconnecting

.. , 89.6

12

-09-

Technical Data OB18L-S0 l0KA Electronic RCBO

Technical Data 'L+N'

••

:-�! ""

�-·

::--�.

))

... , .... ., .. ---

D Conforming Standards:IEC61009-1 GB16917.1 D Breaking Capacity: 1 0000A D Rated Voltage:240V AC D Rated Currentl:6-50A(Electrionic) D Rated Residual Operating Current:30mA, 100mA,300mA D Mechanical Endurance:20,000 D IL::,,m:2000A DType:A,AC

Contacting Status Indication Red:Contacting Green: Disconnecting

Connection Capacity Hard Wire: 16mm2

Flexible Wire: 25mm2

Rated Current(A) Width/Module Package Quantity/Box

6-50 1 1

r

Technical Data-OB18-63 l0KA Electromagnetic RCCB

Technical Data D Conforming Standards:IEC60898-1 GB10963.1 D Breaking Capacity:4500A D Rated Voltage:240V AC D Rated Currentl:1-32A D Mechanical Endurance:20,000 D Ambient Temperature:-25°C-40°C

Superiority

-1\._:Prevent misoperation.RCCB can prevent misoperation causedby transient voltage. For example, thunder,lightning,inductance devices shift.etc.

Contacting Status Indication Red:Product leakage tripping

Description Automatically cut off when earth leakage fault occurs, sensitivity is 30mA, 100mA,300mA. Suitable for residential, commercial and industrial purposes

Rated Current(A) Width/Module

25 2

40 2

63 2

25 4

40 4

63 4

Connection Capacity 25-63A,Hard Wire:16mm2

Flexible Wire: 1 0mm2

80-1 00A,Hard Wire: 16mm2

Flexible Wire:10mm2

n ...

-10-

Package Quantity/Box

1

1

1

1

1

1

72

Page 7: CIRCUIT BREAKER - Znergy

Technical Data OB18-125 l0KA Isolator

Discription Isolator could be switched on, carrying, breaking and

isolating current.

Technical Data D Conforming Standards:IEC60947-3

GB14048.3 AC22

All isolator equiped with red/green indicating window

Superiority Width/Module Package Quantity/Box

1 x63A 240VAC 12

1 x80A 240VAC 12

1 x 100A 240VAC 12

1 x 125A 240VAC 12

Technical Data-Auxiliary

All auxiliaries could combine with monopole or multi pole

circuit breakers.

Design C lassification Description

Auxiliary contact 1 NO+1 NC

Indicating main contact status 6A-240V

in a distance 3A-415V

Shunt Release 240VAC

Operating Voltage:

c€-- 70%-110% Us

C2

Over/Under Voltage Tripping 240VAC

�--

Overvoltage Triping Range:

280V±5%

Undervoltage Tr iping Range:

C2 170V± 5%

Connection Capacity 63-80A,Hard Wire:25mm2

Flexible Wire:16mm2

100A,Hard Wire:35mm2

Flexible Wire:25mm2

125A,Hard Wire:50mm2

Flexible Wire:35mm2

Connection Capacity Hard Wire:6mm2

Flexible Wire:4mm2

Width/Module

1/ 2

1

1

-11-

Installation Dimension

BO182-50

OB18-63

I>

0

OB18-32

72.8

SideA SideB

Package Quantity/Box

OB18-63 1

1

r SldoA

1

l!l

iOB18-25

69.6