12
31.9 (9) CI SFB Enviroseal ® Acoustic Solutions January 07

CI SFB January 07 Enviroseal - ESIcms.esi.info/Media/documents/MannM_Enviroseal_ML.pdf · sliding and folding doors. Can be combined with intumescent materials to add fire spread

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: CI SFB January 07 Enviroseal - ESIcms.esi.info/Media/documents/MannM_Enviroseal_ML.pdf · sliding and folding doors. Can be combined with intumescent materials to add fire spread

31.9 (9)CI SFB

Enviroseal®

Acoustic Solutions

January 07

Page 2: CI SFB January 07 Enviroseal - ESIcms.esi.info/Media/documents/MannM_Enviroseal_ML.pdf · sliding and folding doors. Can be combined with intumescent materials to add fire spread

Worldwide expertise in Seal Solutions

Contents

Worldwide expertise 2

Sound thinking 3

DDI Acoustic Threshold Seal 4

ACS1 Acoustic Retrofit Seal 5

Teardrop Seal 6

MMA6 – Compression Seal 7

Flexifin – Fire, Acoustic & Smoke Seal 8

Testing details 9

Product selector 10

Mann McGowan has been at

the forefront of intumescent

seal technology for over 30

years. Add to that unrivalled

experience and expertise,

dedicated personnel, wide-

ranging technical support and

true worldwide capability, and

it is easy to see why Mann

McGowan is synonymous with

Sealing Solutions at their best.

By devoting considerable

resources to on-going research

and development, the company

constantly improves and extends

its product range, introducing

innovative seal solutions to an

increasingly wide diversity of

applications.

Since its foundation, Mann

McGowan has been continuously

investing in the development of

new products and technologies

to meet the ever-growing

demand for improved fire, cold

smoke, acoustic, weather and

draft sealing, and the challenges

presented to them by ever

changing building techniques and

materials.

Pioneering intumescent seal

encapsulation in 1977, Mann

McGowan set the standards that

are still in use in the building and

construction industries today.

This key technology underpins

the company’s current and future

products.

Every Mann McGowan product

is subject to rigorous quality

control throughout its design and

manufacture. Independent third-

party evaluation and testing to a

range of standards is paramount

in showing compliance to

relevant codes of practice.

Today, Mann McGowan has an

unrivalled global reputation for its

advanced sealing solutions, with

installations in such prestigious

locations as Canary Wharf, The

Victoria and Albert Museum,

Twickenham Rugby Football

Stadium, The Royal Albert Hall,

The Millennium Stadium and as

far afield as Hong Kong Airport

and The Hilton Hotel – Cairo.

Any Mann McGowan product

can be purchased directly from

us via telephone, fax, email or

the World Wide Web and as

always our technical department

is ready on hand to deal with

your enquiries and make sure you

get the right product for your

application.

Technical Enquiries:

01252 333 601

Email:

[email protected]

Web:

www.mannmcgowan.com

Mann McGowan’s Pyrovista glazed

screens and doors create light

and spacious areas; incorporating

Enviroseal® acoustic seals adds

protection from unwanted noise

and other elements.MMA6

Flexifin

Teardrop

ACS1

DDI

Page 3: CI SFB January 07 Enviroseal - ESIcms.esi.info/Media/documents/MannM_Enviroseal_ML.pdf · sliding and folding doors. Can be combined with intumescent materials to add fire spread

Noise pollution is proving

to be an increasing problem

in today’s society and is

recognised as a major

environmental problem

affecting millions of people

around the world. And in

today’s environmentally

sensitive times, using the

most energy efficient methods

available to maintain a

controlled temperature is

equally paramount.

Mann McGowan has enhanced

its highly successful Enviroseal®

range to include Acoustic

Sealing Solutions, offering

complete acoustic, smoke, dust

and ambient weather seals.

Importantly, these seals can be

used in conjunction with Mann

McGowan’s intumescent seals to

provide complete protection.

Acoustic seals help isolate rooms

from airborne noise generated

within a building, such as plant

and machinery, recording studios,

cinemas and interconnected hotel

rooms. They also help isolate

buildings from external traffic

noise from roads, railways and

airports.

Installing seals in the gaps around

a door is the primary method of

reducing sound passing into or

out of a room or building.

Mann McGowan’s Enviroseal®

Acoustic Sealing Solutions include

a highly engineered Acoustic

Threshold Seal as well as a range

of uncomplicated retrofit seals for

door heads and jambs. Together,

they offer an excellent barrier

to airborne sound making the

acoustic attenuation provided by

a door and its frame equivalent to

the wall into which it is installed.

Effective sealing also offers

protection against smoke and

fire, insects and the elements.

Used in combination, Enviroseal®

seals cut heat loss and eliminate

cold draughts - measurably

reducing energy usage – and

prevent the ingress of smoke,

airborne dust and insects.

Now, the Mann McGowan

Enviroseal® range enables

you to meet ever-changing

Building Regulations, the current

requirements of Approved

Document E and Building Bulletin

93, and take into consideration

the Noise Act 1996.

Any queries? Our technical team

is ready to answer your questions,

making sure you get the right

solution for your application.

SymbolsThese icons are used

throughout this brochure

to identify the protective

properties provided by the seals.

The use of these icons does not

indicate that test evidence exists

to support the property.

See page 10 for details of

test reports or contact the

Mann McGowan Technical

Department for full details.

Sound Smoke

Fire Weather

Draught Insect

From Cardiff Arms Park to Bournemouth

Library, Mann McGowan’s Enviroseal®

range provides the sealing solution for

literally hundreds of installations.

Sound thinkingby Mann McGowan

Page 4: CI SFB January 07 Enviroseal - ESIcms.esi.info/Media/documents/MannM_Enviroseal_ML.pdf · sliding and folding doors. Can be combined with intumescent materials to add fire spread

• Available in two sizes 850mm

and 950mm (cut to length

service available at extra cost)

• Easy to fit – fixing positions

readily accessible allowing

quick installation and

minimal machining

• Unique low maintenance

mechanisms

• Lightweight construction

• Concealed, unobtrusive

design suits threshold gaps

up to 8mm

• Non-standard version available

on request to suit threshold

gaps up to 12mm

Technical Information

Full fixing instructions supplied

with the product. Threshold Bars

available on request.

Please contact our Technical Team

if you require additional advice.

Performance

Decibel Rating = 30dB

(BS EN ISO 140-3:1995)

(BS EN ISO 717-1:1997)

Smoke Leakage Rate @ +25pa =

0.00 m3/m/h (metre cubed per

metre of joint per hour)

(BS 476 Part 31.1)

Acoustic performance test

• 44mm Strebord Firecheck

door in a maple frame

• Head and Jambs caulked

both sides

Frequency, Hz

Sou

nd

Red

uct

ion

Ind

ex, d

B

100 125 160 200 250 315 400 500 630 800 1000 1250 1600 2000 2500 3150 4000 5000

Fully caulked door – maximum performance

Head and Jams caulked, DDI Acoustic dropseal installed

50

40

30

20

10

DDI Acoustic Threshold Seal

Spring loaded, the DD1 Acoustic Threshold Seal lifts as soon as

the door is opened, rising clear of carpets and other obstacles,

and lowers to seal when the door closes. Mounted into a 28mm

x 18mm rebate cut into the door’s bottom rail, it operates

automatically by pressure against the doorjamb on its adjustable

strike block. Self-levelling, the DD1 Acoustic Threshold Seal is an

effective component in an acoustic sealing system.

Standard design suits thresholds

gaps between 6 - 8mm. Designs

for gaps up to 12mm available

on request.

6-8mm

Acoustic performance test

Fits 25mm x 15mm

rebate within door foot.

Secured using No 8 Woodscrews.

Page 5: CI SFB January 07 Enviroseal - ESIcms.esi.info/Media/documents/MannM_Enviroseal_ML.pdf · sliding and folding doors. Can be combined with intumescent materials to add fire spread

ACS 1 Acoustic Retrofit Seal

• Easy to fit

• High-tack self-adhesive

• Retrofit design

• No machining required

• Robust rubber material

• Available in a variety of colours

• Supplied in coils of 6m or 12m

for easy storage

Technical Information

Full fixing instructions supplied

with the product.

Please contact our Technical Team

if you require additional advice.

Performance

Decibel Rating = 32dB when

combined with Flexifin Twin and

the DD1 Acoustic Threshold Seal.

(BS EN ISO 140-3:1995)

(BS EN ISO 717-1:1997)

Smoke Leakage Rate @ +25pa =

1.73 m3/m/h (metre cubed per

metre of joint per hour)

(BS 476 Part 31.1)

Acoustic performance test

• 44mm Strebord Firecheck door

in a maple frame

• Head and jambs fitted with

ACS 1 Acoustic Retrofit Seals

• DD1 Acoustic Threshold

Seal installed

Frequency, Hz

Sou

nd

Red

uct

ion

Ind

ex, d

B

100 125 160 200 250 315 400 500 630 800 1000 1250 1600 2000 2500 3150 4000 5000

Fully caulked door – maximum performance

Enviroseal ACS1 and DDI Acoustic dropseal installed

50

40

30

20

10

Acoustic performance test

Designed with simplicity of installation as paramount, the self-

adhesive ACS 1 Acoustic Retrofit Seal allows highly effective

sound, smoke and draft sealing to be added to existing

installations quickly, easily and cost-effectively.

ACS 1 Acoustic Retrofit Seals

provide a simple and easy to fit

acoustic sealing solution, supplied

in coils and available in a variety

of colours.

Page 6: CI SFB January 07 Enviroseal - ESIcms.esi.info/Media/documents/MannM_Enviroseal_ML.pdf · sliding and folding doors. Can be combined with intumescent materials to add fire spread

• Easy to fit

• High-tack self-adhesive

• Retrofit design

• No machining required

• Compression seal

• Available in a variety of colours

• Supplied in lengths up to 3m

Technical Information

Full fixing instructions supplied

with the product.

Please contact our Technical Team

if you require additional advice.

Performance

Decibel Rating = 29dB when

combined with the DD1 Acoustic

Threshold Seal

(BS EN ISO 140-3:1995)

Decibel Rating = 32dB when

combined with Flexifin Twin and

the DD1 Acoustic Threshold Seal

(BS EN ISO 140-3:1995)

(BS EN ISO 717-1:1997)

Smoke Leakage Rate @ +25pa =

0.50 m3/m/h (metre cubed per

metre of joint per hour)

(BS 476 Part 31.1)

Acoustic performance test

• 44mm Strebord Firecheck door

in a maple frame

• Head and jambs fitted with

TD5 Teardrop Seal

• DD1 Acoustic Threshold

Seal installed

Frequency, Hz

Sou

nd

Red

uct

ion

Ind

ex, d

B

100 125 160 200 250 315 400 500 630 800 1000 1250 1600 2000 2500 3150 4000 5000

Fully caulked door – maximum performance

Enviroseal Teardrop and DDI Acoustic dropseal installed

50

40

30

20

10

Acoustic performance test

Designed for simplicity of installation and retrofit, the self-

adhesive semicircular TD5 Teardrop Seal can be quickly located

and fixed both on wooden and steel doors. In addition to

providing an effective barrier against the spread of sound,

cold smoke and draught, it also offers stopping and buffering

properties.

TD5 Teardrop Seals are

available in a variety of

colours and provide excellent

sound reducing performance,

especially when combined

with Flexifin.

Frequency, Hz

Sou

nd

Red

uct

ion

Ind

ex, d

B

100 125 160 200 250 315 400 500 630 800 1000 1250 1600 2000 2500 3150 4000 5000

Fully caulked door – maximum performance

Enviroseal MMA 6 and DDI Acoustic dropseal installed

50

40

30

20

10

TD5 Teardop Seal

Page 7: CI SFB January 07 Enviroseal - ESIcms.esi.info/Media/documents/MannM_Enviroseal_ML.pdf · sliding and folding doors. Can be combined with intumescent materials to add fire spread

• 4-in-1 product

• Suitable for sliding door

applications

• High-tack self-adhesive

• 100.000 open/close cycle test

• Available in a variety of colours

• Can be supplied as a

stand-alone acoustic and

draught seal

• Also available as a combined

fire, acoustic and draught seal

• Firtree seal format available

on request

Technical Information

Full fixing instructions supplied

with the product.

Please contact our Technical Team

if you require additional advice.

Performance

Decibel Rating = 29dB

(BS EN ISO 140-3:1995)

(BS EN ISO 717-1:1997)

Acoustic performance test

• 44mm Strebord Firecheck door

in a maple frame

• Head and jambs fitted with

MMA 6 Compression Seals

• DD1 Acoustic Dropseal

installed.

Frequency, Hz

Sou

nd

Red

uct

ion

Ind

ex, d

B

100 125 160 200 250 315 400 500 630 800 1000 1250 1600 2000 2500 3150 4000 5000

Fully caulked door – maximum performance

Enviroseal MMA 6 and DDI Acoustic dropseal installed

50

40

30

20

10

MMA 6 Compression Seal

The MMA 6, a robust circular profile compression seal offers

sound and draught sealing performance with buffer sealing on

sliding and folding doors. Can be combined with intumescent

materials to add fire spread resistance, creating a highly effective

4-in-1 seal.

MMA 6 Compression Seals are

available in a variety of colours

Acoustic performance test

MMA 6 Compression

seals can also be combined with

an intumescent strip in Mann

McGowans Pyrostrip range for 30

and 60 minute fire protection.

Page 8: CI SFB January 07 Enviroseal - ESIcms.esi.info/Media/documents/MannM_Enviroseal_ML.pdf · sliding and folding doors. Can be combined with intumescent materials to add fire spread

• Robust design

• All-rubber seal

• High-tack self-adhesive

• 100.000 open/close cycle test

• Available in a variety of colours

• Can be supplied as a stand-

alone smoke, acoustic and

draught seal

• Can be combined with various

intumescent specifications for

enhanced performance

• Certifire approved

Technical Information

Full fixing instructions supplied

with the product.

Available in 1000mm, 1050mm,

2050mm and 2100mm lengths.

Non standard lengths are

available on request

Please contact our Technical Team

if you require additional advice.

Performance

Decibel Rating = 32dB

(BS EN ISO 140-3:1995)

(BS EN ISO 717-1:1997)

Smoke Leakage Rate @ +25pa =

1.57 m3/m/h (metre cubed per

metre of joint per hour)

(BS 476 Part 31.1)

Acoustic performance test

• Stop Fitted with either

ACS1 Acoustic Seal or

TD5 Teardrop Seal

• 44mm Strebord Firecheck door

in a maple frame

• Head and jambs fitted with

Flexifin seals

• DD1 Acoustic Dropseal

installed

Frequency, Hz

Sou

nd

Red

uct

ion

Ind

ex, d

B

100 125 160 200 250 315 400 500 630 800 1000 1250 1600 2000 2500 3150 4000 5000

Fully caulked door – maximum performance

Flexifin Twin, Enviroseal Teardrop and DDI Acoustic dropseal installed

50

40

30

20

10

Flexifin® Fire, Acoustic and Smoke seal

A unique innovation in door seal design, Flexifin combines

excellent acoustic sealing properties against the spread of

noise as well as cold smoke and draughts. Flexifin seals can

be combined in a rigid PVC holder with Pyrostrip 100 and 500

intumescent materials to add superb resistance to fire spread.

Acoustic performance test

Flexifin can be

used in combination with a

variety of other seals to provide

complete protection. Flexifin rigid

PVC holders are available in a

variety of colours. Flexifin blades

are manufactured from black

thermoplastic.

Page 9: CI SFB January 07 Enviroseal - ESIcms.esi.info/Media/documents/MannM_Enviroseal_ML.pdf · sliding and folding doors. Can be combined with intumescent materials to add fire spread

Testing beyond specification

10

30

50

70

90

110

130

dB

20 200 2000 20kFrequency [Hz]

Audible range

Music

SpeechBecause noise is not restricted to

100Hz - 4,000Hz, Mann McGowan

tests its Enviroseal® range to

10KHz

The Enviroseal® Acoustic Seals

range has been tested by

UKAS-accredited (No: 0444)

Sound Research Laboratory

in accordance with BS EN ISO

140-3:1995 - and beyond.

The results were presented in

Report C/05/5L/3372/1A.

Test set-up

Airborne sound transmission is

determined from the difference in

sound pressure measured across

a test sample installed between

two reverberant rooms. To ensure

good acoustic isolation, resilient

mountings and seals are used to

isolate the 50m3 receiving room

from the surrounding structure.

The adjoining - source - room has

a volume of 55m3.

An electronic generator, power

amplifier and loudspeaker are

used in the source room to

produce broad band noise. The

resulting sound pressure levels are

sampled in both rooms using a

microphone connected to a real-

time analyser. The sound pressure

level difference [D] across the test

sample is calculated from:

D = LS - LR

where LS is the equivalent sound

pressure difference in the source

room, LR in the receiving room.

The Sound Reduction Index [R]

(USA - Sound Transmission Loss)

is the decibel reduction in sound

energy randomly incident on the

test sample:

where S is the area of the sample

and A the total absorption in the

receiving room.

The Sound Reduction Index is

an expression of a particular

test subject, its mass, thickness,

sealing method, etc., under

laboratory conditions; the actual

sound reduction index achieved

in a particular installation will be

different.

Test conditions

Door: Strebord Firecheck, 850mm

wide x 1980mm high x 44mm

thick with a weight of 50.95kg

Frame: Maple, 34mm x 125mm,

screwed to the wall and sealed

with mastic and mineral wool

Caulk: Arboseal Acoustic Putty

Seals: DD1 Acoustic Threshold

Seal, ACS 1 Acoustic Retrofit Seal,

TD5 Teardrop Seal, Flexifin Twin

Seal and MMA 6 Compression

seal in various combinations.

Frequency, Hz

Sou

nd

Red

uct

ion

Ind

ex, d

B

100 125 160 200 250 315 400 500 630 800 1000 1250 1600 2000 2500 3150 4000 5000

Unsealed door – minimum performance

Fully caulked door – maximum performance

50

40

30

20

10

Acoustic performance test

BS EN ISO 140-3 specifies acoustic testing between frequencies

100Hz and 3,150Hz, US ASTM between 125Hz to 4,000Hz. But

the top note of a piano is 4,186Hz and the frequency content of

speech lies between 125 and 8,000Hz. It is for such reasons that

Mann McGowan Enviroseals® are tested to 10,000Hz, well beyond

the range specified in standards.

R = D + 10Log10 S

A

Page 10: CI SFB January 07 Enviroseal - ESIcms.esi.info/Media/documents/MannM_Enviroseal_ML.pdf · sliding and folding doors. Can be combined with intumescent materials to add fire spread

10

Making the sound choice

We have provided the table below to help you select the right seals combination for your

application. Information is presented as combinations of Enviroseal® seals that provide

a good balance between acoustic performance and other functions, including the DD1

Acoustic Threshold Seal which is essential to maximising performance and meeting the

requirements of Approved Document E.

For maximum performance, Mann McGowan’s recommendation has been highlighted in red.

All Enviroseal® acoustic seals are designed for commercial use, including heavy-duty.

These icons are used to identify

the protective properties of a seal

combination. Use of an icon does

not indicate supporting test data.

FireSound Smoke WeatherDraught Insect

Acoustic Seal Solutions for Standard Non -Fire Rated Systems

DD1 30dB Single Leaf/Single Action - -

DD1/ACS1 30dB Single Leaf/Single Action -

DD1/TD5 29dB Single Leaf/Single Action -

DD1/MMA6 29dB Single Leaf/Single Action -

Acoustic Seal Solutions for Standard 30 Minute Fire Rated Systems

DD1/ACS1/Pyrostrip Flexifin 32dB Single Leaf/Single Action

DD1/TD5/Pyrostrip Flexifin 32dB Single Leaf/Single Action

DD1/MMA6/Pyrostrip 100 29dB Single Leaf/Single Action -

Acoustic Seal Solutions for Standard 60 Minute Fire Rated Systems

DD1/ACS1/Pyrostrip Flexifin 32dB Single Leaf/Single Action

DD1/TD5/Pyrostrip Flexifin 32dB Single Leaf/Single Action

DD1/MMA6/Pyrostrip 100 29dB Single Leaf/Single Action -

Product Acoustic Door Protective PropertiesCombination Performance* Configuration Sound Smoke Fire Draught Weather Insect

* Acoustic Performance – Weighted Sound Reduction Index (Rw).

Red text denotes recommended solution.

Page 11: CI SFB January 07 Enviroseal - ESIcms.esi.info/Media/documents/MannM_Enviroseal_ML.pdf · sliding and folding doors. Can be combined with intumescent materials to add fire spread

The constantly evolving needs of

the built environment means that

building products such as doors,

partitions and glazed screens have

to often perform a number of

technical functions, incorporating

fire resistance with cold smoke

and acoustic levels.

As both a product manufacturer

and installer Mann McGowan

can offer Clients, Architects and

Contractors full turnkey packages

to suit their needs, thus ensuring

full traceability and confidence

from conception to completion.

Both our Sales and Technical teams

undertake approved Continuous

Professional Development

seminars to all interested parties

with the Construction Industry on

a variety of subjects.

Mann McGowan is a Quality

Assured company in accordance

with ISO 9001: 2000 and a number

of products within the range are

Warrington Certifire Approved.

We are active members of a

variety of Trade Associations

including ASDMA, British

Woodwork Federation, GGF (Fire

Resisting Glazing Group) and IFSA.Glass & Glazing

Federation Member

Firas Member

Page 12: CI SFB January 07 Enviroseal - ESIcms.esi.info/Media/documents/MannM_Enviroseal_ML.pdf · sliding and folding doors. Can be combined with intumescent materials to add fire spread

Unit 4, Brook Trading Estate, Deadbrook Lane, Aldershot, Hampshire GU12 4XB England

Telephone: Aldershot +44 (0)1252 333601

Fax: Aldershot +44 (0)1252 322724

Email: [email protected]