1300 East 8th Ave Tampa, FL 33605 CHURCH OF SCIENTOLOGY CLASS V ORG - TAMPA DEMOLITION PACKAGE - 06.11.10 GENSLER Architect 101 Marietta Street NW Suite 3000 Atlanta GA 30303 Contact: Colin O'Brien, Project Manager Juli Abbott, Project Architect Telephone: 404.507.1000 M-ENGINEERING Structural, Mechanical, Electrical, Plumbing Engineer 750 Brooksedge Blvd. Westerville, OH 43081 Contact: Shige Moroi Telephone: 614.839.4639 CHURCH OF SCIENTOLOGY Client 319 South Garden Avenue Clearwater FL 33756 Contact: Uli Huber Telephone: 727.467.6955 CB Richard Ellis Project Manager 189 S. Orange Ave, Suite 1900 Orlando, FL 32801 Contact: Steve Ball Telephone: 407.404.5044

CHURCH OF SCIENTOLOGY - watercraven.com Org/tampaorgdemo.pdfscientology class v org - tampa 1300 east 8th ave tampa, fl 33605 applicable codes drawing index d00.00 cover d00.01 project

Embed Size (px)

Citation preview

1300 East 8th AveTampa, FL 33605

CHURCH OF SCIENTOLOGY

CLASS V ORG - TAMPA

DEMOLITION PACKAGE - 06.11.10

GENSLER

Architect101 Marietta Street NWSuite 3000Atlanta GA 30303Contact: Colin O'Brien, Project ManagerJuli Abbott, Project ArchitectTelephone: 404.507.1000

M-ENGINEERING

Structural, Mechanical, Electrical, Plumbing Engineer750 Brooksedge Blvd.Westerville, OH 43081Contact: Shige MoroiTelephone: 614.839.4639

CHURCH OF SCIENTOLOGY

Client319 South Garden AvenueClearwater FL 33756Contact: Uli HuberTelephone: 727.467.6955

CB Richard Ellis

Project Manager189 S. Orange Ave, Suite 1900Orlando, FL 32801Contact: Steve BallTelephone: 407.404.5044

AACCES ACCESSORYACOUS ACOUSTIC(ALAFF ABOVE FINISHED FLOORAL ALUMINUMALT ALTERNATEANNUNC ANNUNCIATORANOD ANODIZEDAPPL APPLIANCEARCH ARCHITECT(URAL)AUTO AUTOMATICAVG AVERAGE & AND

B BLDG BUILDINGBOLLD BOLLARDBD BOARDBLKG BLOCKINGBRDLM BROADLOOMBU BUILT UP

CCAB CABINETCPT CARPETCEM CEMENT(ITIOUS)CER CERAMICCLG CEILINGCOATG COATINGCOILG COILINGCONC CONCRETECONSTR CONSTRUCTIONCONT CONTINUOUS(ATION)CONTR CONTRACT(OR)COV COVERCMU CONCRETE MASONRY UNIT

D DBL DOUBLEDEPT DEPARTMENTDES DESIGN(ED)DET DETAILDF DRINKING FOUNTAINDIA DIAMETERDIFF DIFFUSERDIM DIMENSIONDISP DISPENSERDIV DIVISIONDN DOWN$ DOLLAR (US CURRENCY)DR DOORDSCON DISCONNECTDWR DRAWER

E ELAST ELASTOMERICELEC ELECTRICALEMBED EMBEDD(ED)(ING)ENGR ENGINEER(ED)ENTR ENTRANCEEQ EQUALEQUIP EQUIPMENTEXIST EXISTINGEXP EXPANSIONEXPS EXPOSE(D)EXT EXTERIOR

F FAB FABRICATIONFD FLOOR DRAINFE FIRE EXTINGUISHERFE&C FIRE EXTINGUISHER & CABINETFHC FIRE HOSE CABINETFIN FINISHFLDG FOLDINGFPLC FIREPLACEFR FIREPLACEFRMG FRAMINGFXD FIXEDFXTR FIXTUREFLR FLOOR(ING)FURN FURNITUREFWC FABRIC WALL COVERING

G GA GAUGEGFRC GLASS FIBER REINFORCED CONCRETEGFRG GLASS FIBER REINFORCED GYPSUMGFRP GLASS FIBER REINFORCED PLASTERGL GLASSGR GRAD(E)(ING)GYP GYPSUM

H HD HEADHDWD HARDWOODHDWE HARDWAREHM HOLLOW METALHORIZ HORIZONTALHVAC HEATING, VENTILATING, AND AIRCONDITIONING

I INFO INFORMATIONINSTRUM INSTRUMENT(ATION)INSUL INSULATIONINTLK INTERLOCK(ING)INT INTERIORINFILTR INFILTRATION

J JAN JANITORJT JOINT

KKIT KITCHEN

L LAV LAVATORYLB POUND£ BRITISH POUND (CURRENCY)LT LIGHTLVLG LEVELINGLVR LOUVER

M MAX MAXIMUMMFD MANUFACTUREDMFR MANUFACTURERMECH MECHANICALMET METALMEMB MEMBRANEMEZZ MEZZANINEMIN MINIMUMMISC MISCELLANEOUSMLWK MILLWORKMOIST MOISTUREMOT MOTOR(IZED)MTD MOUNTED

N NIC NOT IN CONTRACTNO NUMBERNTS NOT TO SCALE

O OFCI OWNER FURNISHED, CONTRACTOR

INSTALLEDCFCI CONTRACTOR FURNISHED,

CONTRACTOR INSTALLEDORNA ORNAMENTALOVFL OVERFLOWOVHD OVERHEADOPNG OPENING(S)OPR OPERABLE

P PTN PARTITIONPEDTR PEDESTRIANPBD PARTICLE BOARDPNL PANELPOLYST POLYSTYRENEPORT PORTABLEPREFIN PREFINISHEDPREFAB PREFABRICATEDPLAM PLASTIC LAMINATEPLAS PLASTERPLSTC PLASTICPLYWD PLYWOODPRTECN PROTECTION

R RDR READERRECES RECESSEDRECPT RECEPTACLEREF REFER(ENCE)REFL REFLECTEDREFR REFRIGERATORREQD REQUIREDRESIS RESIST(ANT)(IVE)REINF REINFORCE(D)(ING)(MENT)RESIL RESILIENTRFG ROOFINGRM ROOMRO ROUGH

S SCR SCRIBESECUR SECURITYSF SQUARE FEETSGL SINGLESHORG SHORINGSIM SIMILARSST STAINLESS STEELSTD STANDARDSTL STEELSTRFR STOREFRONTSTRUCT STRUCTURALSURF SURFACESYS SYSTEM(S)SUSP SUSPENDED T THK THICKTLT TOILETTRAF TRAFFICTRANS TRANSPARENTTRTD TREATEDT&G TONGUE & GROOVETYP TYPICAL

U UNDRLAY UNDERLAYMENTUTIL UTILITYUNO UNLESS NOTED OTHERWISE

V VEH VEHICLEVERT VERTICALVIF VERIFY IN FIELD

W W/ WITHWC WATER CLOSET WD WOODWDW WINDOWW/O WITHOUTWT WEIGHTWTRPRF WATERPROOFING

Gensler

101 Marietta Street NWSuite 3000Atlanta GA 30303Tel: 404.507.1000

© 2010 Gensler

Scale

Description

Project Number

Project Name

Seal/Signature

Issue Date & Issue Description By Check

PLOTTING DATE: FILE PATH AND NAME:

NOT FOR CONSTRUCTION

1 : 1

S:\13.7042.430\BIM\Building Model\_User Model Files\Andrea Henderson_137042430_Tampa.rvt6/11/2010 7:09:40 PM

D00.01

PROJECT INFORMATION, DRAWING INDEX, ABBREVIATIONS

13.7042.430

CLASS V ORG - TAMPA

CHURCH OFSCIENTOLOGYCLASS V ORG - TAMPA1300 East 8th AveTampa, FL 33605

APPLICABLE CODES

DRAWING INDEX

D00.00 COVER

D00.01 PROJECT INFORMATION, DRAWING INDEX, ABBREVIATIONS

D01.00.1 REFERENCE DEMOLITION PLAN - FACTORY

D01.00.2 REFERENCE DEMOLITION PLAN - STEMMERY

D01.10.A DEMOLITION PLAN - FACTORY LEVEL 00 WEST

D01.10.B DEMOLITION PLAN - FACTORY LEVEL 00 EAST, LEVEL 01 SOUTH

D01.11.A DEMOLITION PLAN - FACTORY LEVEL 01 WEST

D01.11.B DEMOLITION PLAN - FACTORY LEVEL 01 EAST

D01.12.A DEMOLITION PLAN - FACTORY LEVEL 02 WEST

D01.12.B DEMOLITION PLAN - FACTORY LEVEL 02 EAST

D01.13.A DEMOLITION PLAN - FACTORY LEVEL 03 WEST

D01.13.B DEMOLITION PLAN - FACTORY LEVEL 03 EAST

D01.21.A DEMOLITION PLAN - STEMMERY LEVEL 01 WEST

D01.21.B DEMOLITION PLAN - STEMMERY LEVEL 01 EAST

D01.22.A DEMOLITION PLAN - STEMMERY LEVEL 02 WEST

D01.22.B DEMOLITION PLAN - STEMMERY LEVEL 02 EAST

D01.23.A DEMOLITION PLAN - STEMMERY LEVEL 03 WEST

D01.23.B DEMOLITION PLAN - STEMMERY LEVEL 03 EAST

GENERAL NOTES

2007 FLORIDA BUILDING CODE:BUILDINGEXISTING BUILDINGPLUMBINGMECHANICALENERGY

2007 FLORIDA FIRE PREVENTION CODE

CITY OF TAMPA MUNICIPAL CODE

1. COMPLY WITH APPLICABLE LOCAL, STATE AND FEDERAL CODES AND REGULATIONSPERTAINING TO SAFETY OF PERSONS, PROPERTY AND ENVIRONMENTAL PROTECTION.

2. PROVIDE AND MAINTAIN BARRICADES, LIGHTING, AND GUARDRAILS AS REQUIRED BYAPPLICABLE CODES AND REGULATIONS TO PROTECTOCCUPANTS OF BUILDING AND WORKERS.

3. ERECT AND MAINTAIN DUSTPROOF PARTITIONS AS REQUIRED TO PREVENT SPREAD OF DUST,FUMES, AND SMOKE, ETC. TO OTHER PARTS OF THE BUIDLING. ON COMPLETION, REMOVEPARTITIONS AND REPAIR DAMAGED SURFACES TO MATCH ADJACENT SURFACES.

4. IF DEMOLITION IS PERFORMED IN EXCESS OF THAT REQUIRED, RESTORE EFFECTED AREAS ATNO COST TO THE OWNER.

5. REMOVE FROM SITE DAILY AND LEGALLY DISPOSE OF REFUSE, DEBRIS, RUBBISH, AND OTHERMATERIALS RESULTING FROM DEMOLITION OPERATIONS IN ACCORDANCE WITH ALL LOCAL,STATE AND FEDERAL LAWS.

6. CONTRACTOR IS RESPONSIBLE FOR PROTECTING THE ADJACENT BUILDINGS, STREET,SIDEWALK, UTILITIES, TREES, ETC...FROM DAMAGE OR HARM AS PART OF THIS SCOPE OFWORK, AS OUTLINED IN THESE DOCUMENTS AND PROJECT MANUAL, AS WELL AS COMPLYINGWITH APPLICABLE LOCAL, STATE, AND FEDERAL CODES AND REGULATIONS.

7. CLEAN ALL DEBRIS FROM FLOORS, WALLS AND CEILING TO REMAIN AFTER MAJORCOMPONENTS ARE DEMOLISHED.

8. VACUUM WALLS, FLOORS, COLUMNS AND CEILING TO RID EACH FLOOR OF DEMOLITION DUST.

9. DEMOLISH ALL MISCELANEOUS WOOD FROM CEILING STRUCTURE (ITEMS TO REMAIN: WOODBEAMS, BEAM CONNECTIONS, FLOOR JOISTS, JOIST BRACING & FLOOR SUBSTRATE & WOODFLOOR) ALL OTHER WOOD ITEMS TO BE REMOVED.

10. IN THE EVENT OF ASBESTOS OR OTHER TOXIC SUBSTANCE EXPOSURE OR THE SUBSTANTIALRISK THEROF, CLIENT WILL HAVE THE DUTY TO INFORM ARCHITECT OFSUCH RISKS KNOWN ORREASONABLY KNOWABLE TO CLIENT. IF ASBESTOS OR ANY OTHER TOXIC SUBSTANCE, OR RISKSTO EXPOSURE THEROF IS DISCOVERED BY ARCHITECT DURING WORK ON THE PROJECT,ARCHITECT SHALL, IN ITS SOLE DISCRETION, HAVE THE RIGHT TO SUSPEND WORK ON THEPROJECT. CLIENT SHALL HAVE THE DUTY PROMPTLY TO RETAIN A QUALIFIED EXPERT SAFELY TORENDER OR SUPERVISE THE REMOVAL OF SUCH ASBESTOS OR OTHER TOXIC SUBSTANCES.CLIENT SHALL INDEMNIFY AND HOLD ARCHITECTS, ITS AFFILIATES AND SUB- CONTRACTORS,AND THEIR OFFICERS, AGENTS AND EMPLOYEES HARMLESS FROM ANY AND ALL LIABILITY ONPART OF OR DAMAGE TO SUCH ENTITIES OR PERSONS, INCLUDING THE COST OF LEGAL FEESAND EXPENSES, AS SUCH FEES AND EXPENSES ARE INCURRED, WHICH MAY RESULT FROMASBESTOS OR OTHER TOXIC SUBSTANCE EXPOSURE ON THE PROJECT.

11. DIVERT CONSTRUCTION WASTE FROM LANDFILL AND RECYCLE REMOVED MATERIALSTO THE GREATEST EXTENT POSSIBLE.

12. VERIFY STRUCTURAL GRID DIMENSIONS IN FIELD.

ARCHITECTURAL DEMOLITION NOTES:

1. ALL EXTERIOR WALLS, EXTERIOR DOORS, AND EXTERIOR WINDOWS ARE HISTORIC AND ARETO REMAIN.

2. ALL COLUMNS TO REMAIN.

3. ALL STAIRS, GUARDRAILS AND HANDRAILS TO REMAIN.

4. REMOVE ALL FLOOR FINISHES AND WALL BASE UNLESS OTHERWISE NOTED

5. WHERE PARTITIONS ABUT MASONRY WALLS AND SUCH PARTITIONS ARE INDICATED TO BEREMOVED, CLEAN MASONRY OF ANY RESIDUE LEFT BY PARTITION INSTALLATION.

6. REMOVE ALL CEILING SYSTEMS UNLESS OTHERWISE NOTED.

7. IF FIRE EXTINGUISHERS AND CABINETS ARE IN PARTITIONS INDICATED TO BE REMOVED,SALVAGE FIRE EXTINGUISHERS AND CABINETS.

HVAC DEMOLITION NOTES:

1. PRIOR TO REMOVAL OF WALLS, THE HVAC CONTRACTOR SHALL IDENTIFY ALL TEMPERATURECONTROL SENSORS AND ASSOCIATE WIRING, TO PREVENT THE REMOVAL OF THESE DEVICESAND ASSOCIATED WIRING.

2. WHERE DUCTWORK IS PASSING THROUGH WALLS BEING REMOVED, THE HVAC CONTRACTORSHALL VERIFY THAT THERE ARE NO DUCTWORK SUPPORTS BEING REMOVED, OR SHALLRE- SUPPORT THE DUCTWORK ACCORDINGLY.

FIRE PROTECTION DEMOLITION NOTES:

1. AFTER REMOVAL OF WALL(S), FIRE PROTECTION CONTRACTOR TO REVIEW SPRINKLER HEADCOVERAGES TO INSURE THAT THERE SHALL BE NO SHORT CIRCUITING OF HEADS DUE TO WA(S)REMOVAL. IF SHORT CIRCUITING OF SPRINKLER HEADS EXISTS, THEN ADJUST HEADSACCORDINGLY.

2. WHERE FIRE PROTECTION LINES ARE PASSING THROUGH WALLS BEING REMOVED, FIREPROTECTION CONTRACTOR SHALL VERIFY THAT THERE ARE NO PIPING SUPPORTS BEINGREMOVED OR SHALL RE-SUPPORT THE FIRE PROTECTIONS LINES ACCORDINGLY.

PLUMBING DEMOLITION NOTES:

1. AFTER REMOVAL OF WALL(S), THE PLUMBING CONTRACTOR SHALL RE-SUPPORT EXISTINGSANITARY AND VENT, DOMESTIC WATER, AND/OR DOMESTIC HOT WATER PIPING AS REQUIRED.

2. ALL PLUMBING FIXTURES, INCLUDING DRINKING FOUNTAINS, AND PLUMBING LINES TO REMAINUNLESS OTHERWISE NOTED.

3. IF ANY PLUMBING FIXTURES ARE IDENTIFIED TO BE REMOVED, THEN ALL ASSOCIATEDSANITARY WASTE, SANITARY VENT, DOMESTIC HOT AND COLD WATER PIPING SHALL BEREMOVED. PLUMBING LINES SHALL BE REMOVED BACK TO THE MAINS AND CAPPED.

4. WHERE PLUMBING LINES ARE PASSING THROUGH WALLS BEING REMOVED, PLUMBINGCONTRACTOR SHALL VERIFY THAT THERE ARE NO PIPING SUPPORTS BEING REMOVED, OR SHALLRE-SUPPORT THE PLUMBING LINES ACCORDINGLY.

ELECTRICAL DEMOLITION NOTES:

1. PRIOR TO REMOVAL OF WALLS, THE ELECTRICAL CONTRACTOR SHALL IDENTIFY ALLRECEPTACLES, LIGHTING FIXTURES, SWITCHES, LIFE SAFETY DEVICES AND ASSOCIATEDWIRING AND CONDUIT, TO PREVENT THE REMOVAL OF THESE DEVICES AND THEIR ASSOCIATEDWIRING AND CONDUIT.

2. REMOVE ALL LIGHT FIXTURES UNLESS OTHERWISE NOTED. LIGHT FIXTURES CONTAININGHAZARDOUS BALLASTS SHALL BE DISPOSED OF PER APPROPRIATE ENVIRONMENTALREQUIREMENTS.

3. WHERE ELECTRICAL DEVICES ARE IDENTIFIED TO BE REMOVED, THEN ALL ASSOCIATEDWIRING AND CONDUIT SHALL BE REMOVED. ELECTRICAL WIRING AND CONDUIT SHALL BEREMOVED BACK TO THE MAIN PANELS.

4. WHERE CONDUIT AND/OR CABLE TRAY IS PASSING THROUGH WALLS BEING REMOVED, THEELECTRICAL CONTRACTOR SHALL VERIFY THAT THERE ARE NO CONDUITS OR CABLE TRAYSUPPORTS BEING REMOVED, OR SHALL RE-SUPPORT THE CONDUITS AND CABLE TRAYSACCORDINGLY.

5. IF A BRANCH DEVICE IS BEING REMOVED, THEN MAINTAIN THE EXISTING CIRCUITING TOMAINTAIN THE EXISTING DEVICES TO REMAIN.

TECHNOLOGY DEMOLITION NOTES:

1. PRIOR TO REMOVAL OF WALLS, THE ELECTRICAL CONTRACTOR OR TECHNOLOGYCONTRACTOR SHALL IDENTIFY ALL VOICE, VIDEO OR DATA DEVICES AND ASSOCIATED WIRINGAND CONDUIT, TO PREVENT THE REMOVAL OF THESE DEVICES AND THEIR ASSOCIATED WIRINGAND CONDUIT.

2. IF ANY TECHNOLOGY DEVICES ARE IDENTIFIED TO BE REMOVED, THEN ALL ASSOCIATEDWIRING AND CONDUIT SHALL BE REMOVED. WIRING AND CONDUIT SHALL BE REMOVED BACK TOTHE MAIN DISTRIBUTION BOARDS.

3. WHERE CONDUIT AND/OR CABLE TRAY IS PASSING THROUGH WALLS BEING REMOVED, THEELECTRICAL CONTRACTOR OR TECHNOLOGY CONTRACTOR SHALL VERIFY THAT THERE ARE NOCONDUITS OR CABLE TRAY SUPPORTS BEING REMOVED, OR SHALL RE-SUPPORT THE CONDUITSAND CABLE TRAYS ACCORDINGLY.

ABBREVIATIONS

PROJECT LOCATION

VICINITY MAP

LOCATION MAP

PROJECT LOCATION

PROJECT INFORMATION

Project Address:1300 East 8th AvenueTampa, Florida 33605

Building Construction:Type III B Sprinklered

Primary Building Occupancy:Group B Business

Gross Building Area:Factory Stemmery

Level 0 5,790 S.F.Level 0 Tunnel 970 S.F.Level 1 15,063 S.F. 12,820 S.F.Level 2 8,228 S.F. 12,854 S.F.Level 3 8,228 S.F. 12,843 S.F.Grand Total 38,279 S.F. 38,517 S.F.

PROJECT DESCRIPTION:THE PROJECT CONSISTS OF TWO BUILDINGS, THE FACTORY AND THE STEMMERY. THEBUILDINGS ARE CONNECTED BY AN UNDERGROUND CORRIDOR. THE BUILDINGS ARE INTHE YBOR CITY AREA WHICH IS DESIGNATED AS A LOCAL HISTORIC DISTRICT. INADDITION, THE TWO BUILDINGS PLUS THE NEIGHBORING WAREHOUSE BUILDING AREALL ON THE NATIONAL HISTORIC REGISTER. THE BUILDING SHELLS ARE CONSIDEREDHISTORIC ELEMENTS. IN THE FACTORY BUILDING, THERE IS A HISTORIC METAL CEILINGAND A HISTORIC STAIR AND GUARDRAIL. IN THE STEMMERY BUILDING, THERE IS AHISTORIC “READER’S PERCH.”

THE BUILDINGS’ STRUCTURE IS EXTERIOR MASONRY BEARING WALLS AND INTERIORWOOD POST-AND-BEAM CONSTRUCTION. THE INTERIORS ARE CURRENTLYCONFIGURED AS OFFICE SPACE WITH NON-BEARING PARTITIONS. THE GENERAL SCOPEOF THIS SELECTIVE DEMOLITION WORK IS TO REMOVE SELECT PARTITIONS, DOORS,CEILING SYSTEMS, FLOOR FINISHES, MILLWORK, PLUMBING FIXTURES AND LIGHTFIXTURES.

DNUP

DN

DN

UPDN

DN

DN

DN

DN

UP

UP

DNUP

DN

DN

DN

D01.10.A

D01.10.B

D01.10.A

D01.10.B

D01.11.A

D01.11.A

D01.11.B

D01.11.B

D01.11.BD01.11.B

D01.10.BD01.10.B

D01.12.A

D01.12.A

D01.12.B

D01.12.B

D01.12.A

D01.12.A

D01.12.B

D01.12.B

Gensler

101 Marietta Street NWSuite 3000Atlanta GA 30303Tel: 404.507.1000

Ref. North

© 2010 Gensler

Scale

Description

Project Number

Project Name

Seal/Signature

Issue Date & Issue Description By Check

PLOTTING DATE: FILE PATH AND NAME:

NOT FOR CONSTRUCTION

1/16" = 1'-0"

S:\13.7042.430\BIM\Building Model\_User Model Files\Andrea Henderson_137042430_Tampa.rvt6/11/2010 7:09:41 PM

D01.00.1

REFERENCE DEMOLITION PLAN - FACTORY

13.7042.430

CLASS V ORG - TAMPA

CHURCH OFSCIENTOLOGYCLASS V ORG - TAMPA1300 East 8th AveTampa, FL 33605

SCALE: 1/16" = 1'-0"

DEMOLITION PLAN - FACTORY LEVEL 00 OVERALL 1

SCALE: 1/16" = 1'-0"

DEMOLITION PLAN - FACTORY LEVEL 01 OVERALL 2

SCALE: 1/16" = 1'-0"

DEMOLITION PLAN - FACTORY LEVEL 02 OVERALL 3

SCALE: 1/16" = 1'-0"

DEMOLITION PLAN - FACTORY LEVEL 03 OVERALL 4

UP

UP

UP

UP

UP

UP

DN

DN

DNDN

D01.21.A

D01.21.B

D01.21.A

D01.21.B

D01.22.A

D01.22.B

D01.22.A

D01.22.B

D01.23.A

D01.23.B

D01.23.A

D01.23.B

Gensler

101 Marietta Street NWSuite 3000Atlanta GA 30303Tel: 404.507.1000

Ref. North

© 2010 Gensler

Scale

Description

Project Number

Project Name

Seal/Signature

Issue Date & Issue Description By Check

PLOTTING DATE: FILE PATH AND NAME:

NOT FOR CONSTRUCTION

1/16" = 1'-0"

S:\13.7042.430\BIM\Building Model\_User Model Files\Andrea Henderson_137042430_Tampa.rvt6/11/2010 7:09:43 PM

D01.00.2

REFERENCE DEMOLITION PLAN - STEMMERY

13.7042.430

CLASS V ORG - TAMPA

CHURCH OFSCIENTOLOGYCLASS V ORG - TAMPA1300 East 8th AveTampa, FL 33605

SCALE: 1/16" = 1'-0"

DEMOLITION PLAN - STEMMERY LEVEL 01 OVERALL 1

SCALE: 1/16" = 1'-0"

DEMOLITION PLAN - STEMMERY LEVEL 02 OVERALL 2SCALE: 1/16" = 1'-0"

DEMOLITION PLAN - STEMMERY LEVEL 03 OVERALL 3

DN

EXISTING WALL TO REMAIN

EXISTING WALL TO BE DEMOLISHED

EXISTING DOOR AND FRAME TO REMAIN

EXISTING DOOR AND FRAME TO BE REMOVEDAND SALVAGED

CF

DF

BF

AF

21F 23F 24F 25F 26F 27F 28F

/1

D01.10.B

/1

D01.10.B

22F

MECHANICAL

ELEVATOR MACHINEROOM

ELEVATOR 1

CORRIDOR

UP STAIR 3

10' - 7 1/2" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0"

1' - 4"

17' - 1"

17' - 3"

25' - 6"

25' - 0 1/2"

0"- 12"

38"

26A01

29A01

TYP

31A01

31A01

TYP

TYP

23A01

TYP

32A01

28A01

32A01

25A01

07A01

07A01

07A01

39A01

MATCHLINE

MATCHLINE

Gensler

101 Marietta Street NWSuite 3000Atlanta GA 30303Tel: 404.507.1000

Ref. North

© 2010 Gensler

Scale

Description

Project Number

Project Name

Seal/Signature

Issue Date & Issue Description By Check

SHEET NOTES

PLOTTING DATE: FILE PATH AND NAME:

NOT FOR CONSTRUCTION

KEY PLAN

LEGEND

# INDICATES SHEET NOTEA00.00

1/4" = 1'-0"

S:\13.7042.430\BIM\Building Model\_User Model Files\Andrea Henderson_137042430_Tampa.rvt6/11/2010 7:09:44 PM

D01.10.A

DEMOLITION PLAN - FACTORY LEVEL 00 WEST

13.7042.430

CLASS V ORG - TAMPA

CHURCH OFSCIENTOLOGYCLASS V ORG - TAMPA1300 East 8th AveTampa, FL 33605

C

BA

01 PARTIAL-HEIGHT ARCHITECTURALPILASTERS TO BE REMOVED

02 DEMOUNTABLE PARTITION TO BE REMOVED

03 WINDOW WALL TO BE REMOVED

04 MILLWORK TO BE REMOVED

05 MILLWORK TO REMAIN

06 PLUMBING FIXTURE TO BE REMOVED

07 ALL ELECTRICAL DEVICES, FLOOR FINISHES,WALL BASE, CEILING SYSTEMS IN THISROOM/CORRIDOR TO REMAIN

08 CEILING SYSTEM IN THIS ROOM/CORRIDORTO REMAIN

09 HISTORIC METAL CEILING SYSTEM IN THISROOM TO REMAIN

10 WINDOW WALL TO REMAIN

11 SIDELITE TO BE REMOVED

12 SIDELITE TO REMAIN

13 WINDOW TO REMAIN

14 REMOVE WINDOW AND MASONRY BELOWWINDOW OPENING TO BE FLUSH WITHADJACENT SUBFLOOR

15 HISTORIC GUARDRAIL TO REMAIN

16 HISTORIC STAIR TO REMAIN

17 COUNTER AND WALL BELOW TO BEREMOVED

18 CROWN MOULDING IN THIS OFFICE SUITETO BE REMOVED

19 HISTORIC “READER’S PERCH” TO REMAIN

20 SLIDING WALL SYSTEM TO BE REMOVED

21 BRICK MASONRY PILASTERS AND METALSERVICE GATE

22 EDGE OF BRIDGE ABOVE

23 CLERESTORY WINDOW

24 STEPS

25 RAMP

26 CHANGE IN SLAB LEVEL

27 MASONRY WALL

28 PARTIAL HEIGHT BRICK FOUNDATION WALL

29 MASONRY BUTTRESS

30 MASONRY COLUMN

31 MASONRY FOUNDATION AT COLUMN

32 STEEL COLUMN

33 WOOD COLUMN

34 CONCRETE FOUNDATION AT COLUMN

35 RAISED FLOOR SYSTEM TO BE REMOVEDAND SALVAGED

36 MILLWORK TO BE SALVAGED - PLACE ONFLOOR SLAB AFTER REMOVAL OF RAISEDFLOOR SYSTEM

37 REMOVE UPPER CABINET AND PLACE ONFLOOR SLAB IN THIS ROOM

38 OUTLINE OF EXISTING ROOF ABOVE

39 CHILLED WATER LINES TO REMAIN

40 CONTRACTOR TO VERIFY IF ANY STEPSEXIST BELOW RAISED FLOORING AND TOSUBMIT DOCUMENTATION TO ARCHITECT

41 DOOR ABOVE SHOWN DASHED BUTSCHEDULED TO REMAIN

UP

DN

EXISTING WALL TO REMAIN

EXISTING WALL TO BE DEMOLISHED

EXISTING DOOR AND FRAME TO REMAIN

EXISTING DOOR AND FRAME TO BE REMOVEDAND SALVAGED

CF

DF

BF

28F 29F 30F 31F 32F 33F 34F 35F

/1

D01.10.A

/1

D01.10.A

10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 11' - 6 1/2"

17' - 3"

17' - 1"

1' - 4"

38"

- 12" 0"

ELECTRICAL ROOM

CHILLED WATERPUMP ROOM

ELEVATOR MACHINEROOM ELECTRICAL ROOM

TELEPHONE ROOM

STAIR 2

23A01

TYP

29A01

TYP

32A01

28A01

26A01

32A01

30A01

TYP

31A01

TYP

07A01

24A01

07A01

07A01

07A01

07A01

MATCHLINE

MATCHLINE

/1 D01.11.B /1 D01.11.B

STAIR 8

09A01

A D J A C E N T B U I L D I N G - N. I. C.

P L A N T E RN. I. C.

MATCHLINEMATCHLINE

45' - 5"

22' - 0 1/2"

9' - 9" 9' - 9" 10' - 11"

Gensler

101 Marietta Street NWSuite 3000Atlanta GA 30303Tel: 404.507.1000

Ref. North

© 2010 Gensler

Scale

Description

Project Number

Project Name

Seal/Signature

Issue Date & Issue Description By Check

SHEET NOTES

PLOTTING DATE: FILE PATH AND NAME:

NOT FOR CONSTRUCTION

KEY PLAN

LEGEND

# INDICATES SHEET NOTEA00.00

1/4" = 1'-0"

S:\13.7042.430\BIM\Building Model\_User Model Files\Andrea Henderson_137042430_Tampa.rvt6/11/2010 7:09:46 PM

D01.10.B

DEMOLITION PLAN - FACTORY LEVEL 00 EAST, LEVEL 01 SOUTH

13.7042.430

CLASS V ORG - TAMPA

CHURCH OFSCIENTOLOGYCLASS V ORG - TAMPA1300 East 8th AveTampa, FL 33605

C

BA

01 PARTIAL-HEIGHT ARCHITECTURALPILASTERS TO BE REMOVED

02 DEMOUNTABLE PARTITION TO BE REMOVED

03 WINDOW WALL TO BE REMOVED

04 MILLWORK TO BE REMOVED

05 MILLWORK TO REMAIN

06 PLUMBING FIXTURE TO BE REMOVED

07 ALL ELECTRICAL DEVICES, FLOOR FINISHES,WALL BASE, CEILING SYSTEMS IN THISROOM/CORRIDOR TO REMAIN

08 CEILING SYSTEM IN THIS ROOM/CORRIDORTO REMAIN

09 HISTORIC METAL CEILING SYSTEM IN THISROOM TO REMAIN

10 WINDOW WALL TO REMAIN

11 SIDELITE TO BE REMOVED

12 SIDELITE TO REMAIN

13 WINDOW TO REMAIN

14 REMOVE WINDOW AND MASONRY BELOWWINDOW OPENING TO BE FLUSH WITHADJACENT SUBFLOOR

15 HISTORIC GUARDRAIL TO REMAIN

16 HISTORIC STAIR TO REMAIN

17 COUNTER AND WALL BELOW TO BEREMOVED

18 CROWN MOULDING IN THIS OFFICE SUITETO BE REMOVED

19 HISTORIC “READER’S PERCH” TO REMAIN

20 SLIDING WALL SYSTEM TO BE REMOVED

21 BRICK MASONRY PILASTERS AND METALSERVICE GATE

22 EDGE OF BRIDGE ABOVE

23 CLERESTORY WINDOW

24 STEPS

25 RAMP

26 CHANGE IN SLAB LEVEL

27 MASONRY WALL

28 PARTIAL HEIGHT BRICK FOUNDATION WALL

29 MASONRY BUTTRESS

30 MASONRY COLUMN

31 MASONRY FOUNDATION AT COLUMN

32 STEEL COLUMN

33 WOOD COLUMN

34 CONCRETE FOUNDATION AT COLUMN

35 RAISED FLOOR SYSTEM TO BE REMOVEDAND SALVAGED

36 MILLWORK TO BE SALVAGED - PLACE ONFLOOR SLAB AFTER REMOVAL OF RAISEDFLOOR SYSTEM

37 REMOVE UPPER CABINET AND PLACE ONFLOOR SLAB IN THIS ROOM

38 OUTLINE OF EXISTING ROOF ABOVE

39 CHILLED WATER LINES TO REMAIN

40 CONTRACTOR TO VERIFY IF ANY STEPSEXIST BELOW RAISED FLOORING AND TOSUBMIT DOCUMENTATION TO ARCHITECT

41 DOOR ABOVE SHOWN DASHED BUTSCHEDULED TO REMAIN

SCALE: 1/4" = 1'-0"

DEMOLITION PLAN - FACTORY LEVEL 00 EAST 1

SCALE: 1/4" = 1'-0"

DEMOLITION PLAN - FACTORY LEVEL 01 SOUTH 2

DN

DN

UP

EXISTING WALL TO REMAIN

EXISTING WALL TO BE DEMOLISHED

EXISTING DOOR AND FRAME TO REMAIN

EXISTING DOOR AND FRAME TO BE REMOVEDAND SALVAGED

CF

DF

BF

AF

1F

21F 23F

2F 3F

24F 25F 26F

6F

27F

7F

28F

8F

/1

D01.11.B

/1

D01.11.B

22F

5F4F

10' - 7 1/2" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0"

1' - 4"

17' - 1"

17' - 3"

25' - 6"

24' - 11 1/2"

STAIR 1

MEN'S RESTROOM

WOMEN'SRESTROOM

JANITOR CLOSET

ELEVATOR 1

STAIR 6

STAIR 5

DN STAIR 3

33A01

38A01

11A01

33A01

12A01

27A01

27A01

03A01

10A01

05A01

05A01

07A01

06A01

04A01

04A01

27A01

11A01

14A01

MAX

9' - 6"

P L A N T E RN. I. C.

MATCHLINE

MATCHLINE

P O R C HN. I. C.

12' - 4" 9' - 3" 10' - 2 1/2" 11' - 2 1/2" 10' - 11" 9' - 6" 9' - 11" 9' - 9"

Gensler

101 Marietta Street NWSuite 3000Atlanta GA 30303Tel: 404.507.1000

Ref. North

© 2010 Gensler

Scale

Description

Project Number

Project Name

Seal/Signature

Issue Date & Issue Description By Check

SHEET NOTES

PLOTTING DATE: FILE PATH AND NAME:

NOT FOR CONSTRUCTION

KEY PLAN

LEGEND

# INDICATES SHEET NOTEA00.00

1/4" = 1'-0"

S:\13.7042.430\BIM\Building Model\_User Model Files\Andrea Henderson_137042430_Tampa.rvt6/11/2010 7:09:48 PM

D01.11.A

DEMOLITION PLAN - FACTORY LEVEL 01 WEST

13.7042.430

CLASS V ORG - TAMPA

CHURCH OFSCIENTOLOGYCLASS V ORG - TAMPA1300 East 8th AveTampa, FL 33605

C

BA

01 PARTIAL-HEIGHT ARCHITECTURALPILASTERS TO BE REMOVED

02 DEMOUNTABLE PARTITION TO BE REMOVED

03 WINDOW WALL TO BE REMOVED

04 MILLWORK TO BE REMOVED

05 MILLWORK TO REMAIN

06 PLUMBING FIXTURE TO BE REMOVED

07 ALL ELECTRICAL DEVICES, FLOOR FINISHES,WALL BASE, CEILING SYSTEMS IN THISROOM/CORRIDOR TO REMAIN

08 CEILING SYSTEM IN THIS ROOM/CORRIDORTO REMAIN

09 HISTORIC METAL CEILING SYSTEM IN THISROOM TO REMAIN

10 WINDOW WALL TO REMAIN

11 SIDELITE TO BE REMOVED

12 SIDELITE TO REMAIN

13 WINDOW TO REMAIN

14 REMOVE WINDOW AND MASONRY BELOWWINDOW OPENING TO BE FLUSH WITHADJACENT SUBFLOOR

15 HISTORIC GUARDRAIL TO REMAIN

16 HISTORIC STAIR TO REMAIN

17 COUNTER AND WALL BELOW TO BEREMOVED

18 CROWN MOULDING IN THIS OFFICE SUITETO BE REMOVED

19 HISTORIC “READER’S PERCH” TO REMAIN

20 SLIDING WALL SYSTEM TO BE REMOVED

21 BRICK MASONRY PILASTERS AND METALSERVICE GATE

22 EDGE OF BRIDGE ABOVE

23 CLERESTORY WINDOW

24 STEPS

25 RAMP

26 CHANGE IN SLAB LEVEL

27 MASONRY WALL

28 PARTIAL HEIGHT BRICK FOUNDATION WALL

29 MASONRY BUTTRESS

30 MASONRY COLUMN

31 MASONRY FOUNDATION AT COLUMN

32 STEEL COLUMN

33 WOOD COLUMN

34 CONCRETE FOUNDATION AT COLUMN

35 RAISED FLOOR SYSTEM TO BE REMOVEDAND SALVAGED

36 MILLWORK TO BE SALVAGED - PLACE ONFLOOR SLAB AFTER REMOVAL OF RAISEDFLOOR SYSTEM

37 REMOVE UPPER CABINET AND PLACE ONFLOOR SLAB IN THIS ROOM

38 OUTLINE OF EXISTING ROOF ABOVE

39 CHILLED WATER LINES TO REMAIN

40 CONTRACTOR TO VERIFY IF ANY STEPSEXIST BELOW RAISED FLOORING AND TOSUBMIT DOCUMENTATION TO ARCHITECT

41 DOOR ABOVE SHOWN DASHED BUTSCHEDULED TO REMAIN

DN

DN

UP

DN

EXISTING WALL TO REMAIN

EXISTING WALL TO BE DEMOLISHED

EXISTING DOOR AND FRAME TO REMAIN

EXISTING DOOR AND FRAME TO BE REMOVEDAND SALVAGED

CF

DF

BF

AF

28F

8F

29F

9F

30F

10F

31F

11F

32F

12F

33F

13F

34F

14F

35F

15F

/1

D01.11.A

/1

D01.11.A

/2 D01.10.B /2 D01.10.B

10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 11' - 6 1/2"

1' - 4"

17' - 1"

17' - 3"

25' - 6"

24' - 11 1/2"

MECHANICAL

ELECTRICAL

STAIR 2

STAIR 9

STAIR 4

STAIR 10

STAIR 7

33A01

14A01

27A01

33A01

33A01

TYP

23A01

38A01

07A01

07A01

04A01

04A01

06A01

16A01

P L A N T E RN. I. C.

P L A N T E RN. I. C.

MATCHLINE

MATCHLINE

MATCHLINEMATCHLINE

9' - 8" 9' - 9" 9' - 9" 9' - 9" 9' - 9" 9' - 9" 9' - 9" 10' - 11"

32A01

Gensler

101 Marietta Street NWSuite 3000Atlanta GA 30303Tel: 404.507.1000

Ref. North

© 2010 Gensler

Scale

Description

Project Number

Project Name

Seal/Signature

Issue Date & Issue Description By Check

SHEET NOTES

PLOTTING DATE: FILE PATH AND NAME:

NOT FOR CONSTRUCTION

KEY PLAN

LEGEND

# INDICATES SHEET NOTEA00.00

1/4" = 1'-0"

S:\13.7042.430\BIM\Building Model\_User Model Files\Andrea Henderson_137042430_Tampa.rvt6/11/2010 7:09:49 PM

D01.11.B

DEMOLITION PLAN - FACTORY LEVEL 01 EAST

13.7042.430

CLASS V ORG - TAMPA

CHURCH OFSCIENTOLOGYCLASS V ORG - TAMPA1300 East 8th AveTampa, FL 33605

C

BA

01 PARTIAL-HEIGHT ARCHITECTURALPILASTERS TO BE REMOVED

02 DEMOUNTABLE PARTITION TO BE REMOVED

03 WINDOW WALL TO BE REMOVED

04 MILLWORK TO BE REMOVED

05 MILLWORK TO REMAIN

06 PLUMBING FIXTURE TO BE REMOVED

07 ALL ELECTRICAL DEVICES, FLOOR FINISHES,WALL BASE, CEILING SYSTEMS IN THISROOM/CORRIDOR TO REMAIN

08 CEILING SYSTEM IN THIS ROOM/CORRIDORTO REMAIN

09 HISTORIC METAL CEILING SYSTEM IN THISROOM TO REMAIN

10 WINDOW WALL TO REMAIN

11 SIDELITE TO BE REMOVED

12 SIDELITE TO REMAIN

13 WINDOW TO REMAIN

14 REMOVE WINDOW AND MASONRY BELOWWINDOW OPENING TO BE FLUSH WITHADJACENT SUBFLOOR

15 HISTORIC GUARDRAIL TO REMAIN

16 HISTORIC STAIR TO REMAIN

17 COUNTER AND WALL BELOW TO BEREMOVED

18 CROWN MOULDING IN THIS OFFICE SUITETO BE REMOVED

19 HISTORIC “READER’S PERCH” TO REMAIN

20 SLIDING WALL SYSTEM TO BE REMOVED

21 BRICK MASONRY PILASTERS AND METALSERVICE GATE

22 EDGE OF BRIDGE ABOVE

23 CLERESTORY WINDOW

24 STEPS

25 RAMP

26 CHANGE IN SLAB LEVEL

27 MASONRY WALL

28 PARTIAL HEIGHT BRICK FOUNDATION WALL

29 MASONRY BUTTRESS

30 MASONRY COLUMN

31 MASONRY FOUNDATION AT COLUMN

32 STEEL COLUMN

33 WOOD COLUMN

34 CONCRETE FOUNDATION AT COLUMN

35 RAISED FLOOR SYSTEM TO BE REMOVEDAND SALVAGED

36 MILLWORK TO BE SALVAGED - PLACE ONFLOOR SLAB AFTER REMOVAL OF RAISEDFLOOR SYSTEM

37 REMOVE UPPER CABINET AND PLACE ONFLOOR SLAB IN THIS ROOM

38 OUTLINE OF EXISTING ROOF ABOVE

39 CHILLED WATER LINES TO REMAIN

40 CONTRACTOR TO VERIFY IF ANY STEPSEXIST BELOW RAISED FLOORING AND TOSUBMIT DOCUMENTATION TO ARCHITECT

41 DOOR ABOVE SHOWN DASHED BUTSCHEDULED TO REMAIN

DN

AF

1F 2F 3F 6F 7F 8F

/1

D01.12.B

/1

D01.12.B

5F4F

12' - 4" 9' - 3" 10' - 2 1/2" 11' - 2 1/2" 10' - 11" 9' - 6" 9' - 11" 9' - 9"

24' - 11 1/2"

25' - 2"

STAIR 1

WOMEN'SRESTROOM

MEN'S RESTROOM

ELEVATOR 1

27A01

27A01

33A01

17A01

12A01

05A01

R O O F B E L O WN. I. C.

R O O FB E L O WN. I. C.

UP

MATCHLINE

MATCHLINE

EXISTING WALL TO REMAIN

EXISTING WALL TO BE DEMOLISHED

EXISTING DOOR AND FRAME TO REMAIN

EXISTING DOOR AND FRAME TO BE REMOVEDAND SALVAGED

Gensler

101 Marietta Street NWSuite 3000Atlanta GA 30303Tel: 404.507.1000

Ref. North

© 2010 Gensler

Scale

Description

Project Number

Project Name

Seal/Signature

Issue Date & Issue Description By Check

SHEET NOTES

PLOTTING DATE: FILE PATH AND NAME:

NOT FOR CONSTRUCTION

KEY PLAN

LEGEND

# INDICATES SHEET NOTEA00.00

1/4" = 1'-0"

S:\13.7042.430\BIM\Building Model\_User Model Files\Andrea Henderson_137042430_Tampa.rvt6/11/2010 7:09:51 PM

D01.12.A

DEMOLITION PLAN - FACTORY LEVEL 02 WEST

13.7042.430

CLASS V ORG - TAMPA

CHURCH OFSCIENTOLOGYCLASS V ORG - TAMPA1300 East 8th AveTampa, FL 33605

01 PARTIAL-HEIGHT ARCHITECTURALPILASTERS TO BE REMOVED

02 DEMOUNTABLE PARTITION TO BE REMOVED

03 WINDOW WALL TO BE REMOVED

04 MILLWORK TO BE REMOVED

05 MILLWORK TO REMAIN

06 PLUMBING FIXTURE TO BE REMOVED

07 ALL ELECTRICAL DEVICES, FLOOR FINISHES,WALL BASE, CEILING SYSTEMS IN THISROOM/CORRIDOR TO REMAIN

08 CEILING SYSTEM IN THIS ROOM/CORRIDORTO REMAIN

09 HISTORIC METAL CEILING SYSTEM IN THISROOM TO REMAIN

10 WINDOW WALL TO REMAIN

11 SIDELITE TO BE REMOVED

12 SIDELITE TO REMAIN

13 WINDOW TO REMAIN

14 REMOVE WINDOW AND MASONRY BELOWWINDOW OPENING TO BE FLUSH WITHADJACENT SUBFLOOR

15 HISTORIC GUARDRAIL TO REMAIN

16 HISTORIC STAIR TO REMAIN

17 COUNTER AND WALL BELOW TO BEREMOVED

18 CROWN MOULDING IN THIS OFFICE SUITETO BE REMOVED

19 HISTORIC “READER’S PERCH” TO REMAIN

20 SLIDING WALL SYSTEM TO BE REMOVED

21 BRICK MASONRY PILASTERS AND METALSERVICE GATE

22 EDGE OF BRIDGE ABOVE

23 CLERESTORY WINDOW

24 STEPS

25 RAMP

26 CHANGE IN SLAB LEVEL

27 MASONRY WALL

28 PARTIAL HEIGHT BRICK FOUNDATION WALL

29 MASONRY BUTTRESS

30 MASONRY COLUMN

31 MASONRY FOUNDATION AT COLUMN

32 STEEL COLUMN

33 WOOD COLUMN

34 CONCRETE FOUNDATION AT COLUMN

35 RAISED FLOOR SYSTEM TO BE REMOVEDAND SALVAGED

36 MILLWORK TO BE SALVAGED - PLACE ONFLOOR SLAB AFTER REMOVAL OF RAISEDFLOOR SYSTEM

37 REMOVE UPPER CABINET AND PLACE ONFLOOR SLAB IN THIS ROOM

38 OUTLINE OF EXISTING ROOF ABOVE

39 CHILLED WATER LINES TO REMAIN

40 CONTRACTOR TO VERIFY IF ANY STEPSEXIST BELOW RAISED FLOORING AND TOSUBMIT DOCUMENTATION TO ARCHITECT

41 DOOR ABOVE SHOWN DASHED BUTSCHEDULED TO REMAIN

BA

DN

UP

AF

8F 9F 10F 11F 12F 13F 14F 15F

/1

D01.12.A

/1

D01.12.A

24' - 11 1/2"

25' - 2"

9' - 8" 9' - 9" 9' - 9" 9' - 9" 9' - 9" 9' - 9" 9' - 9" 10' - 11"

33A01

12A01

12A01

11A01

15A01

07A01

07A01

MECHANICAL ROOM ELECTRICAL ROOM

STAIR 2

MAX

6' - 8"

MATCHLINE

MATCHLINE

R O O F B E L O WN. I. C.

EXISTING WALL TO REMAIN

EXISTING WALL TO BE DEMOLISHED

EXISTING DOOR AND FRAME TO REMAIN

EXISTING DOOR AND FRAME TO BE REMOVEDAND SALVAGED

Gensler

101 Marietta Street NWSuite 3000Atlanta GA 30303Tel: 404.507.1000

Ref. North

© 2010 Gensler

Scale

Description

Project Number

Project Name

Seal/Signature

Issue Date & Issue Description By Check

SHEET NOTES

PLOTTING DATE: FILE PATH AND NAME:

NOT FOR CONSTRUCTION

KEY PLAN

LEGEND

# INDICATES SHEET NOTEA00.00

1/4" = 1'-0"

S:\13.7042.430\BIM\Building Model\_User Model Files\Andrea Henderson_137042430_Tampa.rvt6/11/2010 7:09:52 PM

D01.12.B

DEMOLITION PLAN - FACTORY LEVEL 02 EAST

13.7042.430

CLASS V ORG - TAMPA

CHURCH OFSCIENTOLOGYCLASS V ORG - TAMPA1300 East 8th AveTampa, FL 33605

01 PARTIAL-HEIGHT ARCHITECTURALPILASTERS TO BE REMOVED

02 DEMOUNTABLE PARTITION TO BE REMOVED

03 WINDOW WALL TO BE REMOVED

04 MILLWORK TO BE REMOVED

05 MILLWORK TO REMAIN

06 PLUMBING FIXTURE TO BE REMOVED

07 ALL ELECTRICAL DEVICES, FLOOR FINISHES,WALL BASE, CEILING SYSTEMS IN THISROOM/CORRIDOR TO REMAIN

08 CEILING SYSTEM IN THIS ROOM/CORRIDORTO REMAIN

09 HISTORIC METAL CEILING SYSTEM IN THISROOM TO REMAIN

10 WINDOW WALL TO REMAIN

11 SIDELITE TO BE REMOVED

12 SIDELITE TO REMAIN

13 WINDOW TO REMAIN

14 REMOVE WINDOW AND MASONRY BELOWWINDOW OPENING TO BE FLUSH WITHADJACENT SUBFLOOR

15 HISTORIC GUARDRAIL TO REMAIN

16 HISTORIC STAIR TO REMAIN

17 COUNTER AND WALL BELOW TO BEREMOVED

18 CROWN MOULDING IN THIS OFFICE SUITETO BE REMOVED

19 HISTORIC “READER’S PERCH” TO REMAIN

20 SLIDING WALL SYSTEM TO BE REMOVED

21 BRICK MASONRY PILASTERS AND METALSERVICE GATE

22 EDGE OF BRIDGE ABOVE

23 CLERESTORY WINDOW

24 STEPS

25 RAMP

26 CHANGE IN SLAB LEVEL

27 MASONRY WALL

28 PARTIAL HEIGHT BRICK FOUNDATION WALL

29 MASONRY BUTTRESS

30 MASONRY COLUMN

31 MASONRY FOUNDATION AT COLUMN

32 STEEL COLUMN

33 WOOD COLUMN

34 CONCRETE FOUNDATION AT COLUMN

35 RAISED FLOOR SYSTEM TO BE REMOVEDAND SALVAGED

36 MILLWORK TO BE SALVAGED - PLACE ONFLOOR SLAB AFTER REMOVAL OF RAISEDFLOOR SYSTEM

37 REMOVE UPPER CABINET AND PLACE ONFLOOR SLAB IN THIS ROOM

38 OUTLINE OF EXISTING ROOF ABOVE

39 CHILLED WATER LINES TO REMAIN

40 CONTRACTOR TO VERIFY IF ANY STEPSEXIST BELOW RAISED FLOORING AND TOSUBMIT DOCUMENTATION TO ARCHITECT

41 DOOR ABOVE SHOWN DASHED BUTSCHEDULED TO REMAIN

BA

DN

AF

1F 2F 3F 6F 7F 8F

/1

D01.13.B

/1

D01.13.B

5F4F

12' - 4" 9' - 3" 10' - 2 1/2" 11' - 2 1/2" 10' - 11" 9' - 6" 9' - 11" 9' - 9"

25' - 2"

24' - 11 1/2"

17A01

29A01

29A01

ELEVATOR 1

STAIR 1

MIN

7' - 0"

MIN

4' - 0"

MATCHLINE

MATCHLINE

EXISTING WALL TO REMAIN

EXISTING WALL TO BE DEMOLISHED

EXISTING DOOR AND FRAME TO REMAIN

EXISTING DOOR AND FRAME TO BE REMOVEDAND SALVAGED

Gensler

101 Marietta Street NWSuite 3000Atlanta GA 30303Tel: 404.507.1000

Ref. North

© 2010 Gensler

Scale

Description

Project Number

Project Name

Seal/Signature

Issue Date & Issue Description By Check

SHEET NOTES

PLOTTING DATE: FILE PATH AND NAME:

NOT FOR CONSTRUCTION

KEY PLAN

LEGEND

# INDICATES SHEET NOTEA00.00

1/4" = 1'-0"

S:\13.7042.430\BIM\Building Model\_User Model Files\Andrea Henderson_137042430_Tampa.rvt6/11/2010 7:09:53 PM

D01.13.A

DEMOLITION PLAN - FACTORY LEVEL 03 WEST

13.7042.430

CLASS V ORG - TAMPA

CHURCH OFSCIENTOLOGYCLASS V ORG - TAMPA1300 East 8th AveTampa, FL 33605

01 PARTIAL-HEIGHT ARCHITECTURALPILASTERS TO BE REMOVED

02 DEMOUNTABLE PARTITION TO BE REMOVED

03 WINDOW WALL TO BE REMOVED

04 MILLWORK TO BE REMOVED

05 MILLWORK TO REMAIN

06 PLUMBING FIXTURE TO BE REMOVED

07 ALL ELECTRICAL DEVICES, FLOOR FINISHES,WALL BASE, CEILING SYSTEMS IN THISROOM/CORRIDOR TO REMAIN

08 CEILING SYSTEM IN THIS ROOM/CORRIDORTO REMAIN

09 HISTORIC METAL CEILING SYSTEM IN THISROOM TO REMAIN

10 WINDOW WALL TO REMAIN

11 SIDELITE TO BE REMOVED

12 SIDELITE TO REMAIN

13 WINDOW TO REMAIN

14 REMOVE WINDOW AND MASONRY BELOWWINDOW OPENING TO BE FLUSH WITHADJACENT SUBFLOOR

15 HISTORIC GUARDRAIL TO REMAIN

16 HISTORIC STAIR TO REMAIN

17 COUNTER AND WALL BELOW TO BEREMOVED

18 CROWN MOULDING IN THIS OFFICE SUITETO BE REMOVED

19 HISTORIC “READER’S PERCH” TO REMAIN

20 SLIDING WALL SYSTEM TO BE REMOVED

21 BRICK MASONRY PILASTERS AND METALSERVICE GATE

22 EDGE OF BRIDGE ABOVE

23 CLERESTORY WINDOW

24 STEPS

25 RAMP

26 CHANGE IN SLAB LEVEL

27 MASONRY WALL

28 PARTIAL HEIGHT BRICK FOUNDATION WALL

29 MASONRY BUTTRESS

30 MASONRY COLUMN

31 MASONRY FOUNDATION AT COLUMN

32 STEEL COLUMN

33 WOOD COLUMN

34 CONCRETE FOUNDATION AT COLUMN

35 RAISED FLOOR SYSTEM TO BE REMOVEDAND SALVAGED

36 MILLWORK TO BE SALVAGED - PLACE ONFLOOR SLAB AFTER REMOVAL OF RAISEDFLOOR SYSTEM

37 REMOVE UPPER CABINET AND PLACE ONFLOOR SLAB IN THIS ROOM

38 OUTLINE OF EXISTING ROOF ABOVE

39 CHILLED WATER LINES TO REMAIN

40 CONTRACTOR TO VERIFY IF ANY STEPSEXIST BELOW RAISED FLOORING AND TOSUBMIT DOCUMENTATION TO ARCHITECT

41 DOOR ABOVE SHOWN DASHED BUTSCHEDULED TO REMAIN

BA

DN

AF

8F 9F 10F 11F 12F 13F 14F 15F

/1

D01.13.A

/1

D01.13.A

9' - 8" 9' - 9" 9' - 9" 9' - 9" 9' - 9" 9' - 9" 9' - 9" 10' - 11"

25' - 2"

24' - 11 1/2"

06A01

04A01

05A01

07A01

05A01

07A01

07A01

07A01

STAIR 2

JANITOR

ELECTRICAL

STAIR 11

TELEPHONE

MATCHLINE

MATCHLINE

EXISTING WALL TO REMAIN

EXISTING WALL TO BE DEMOLISHED

EXISTING DOOR AND FRAME TO REMAIN

EXISTING DOOR AND FRAME TO BE REMOVEDAND SALVAGED

Gensler

101 Marietta Street NWSuite 3000Atlanta GA 30303Tel: 404.507.1000

Ref. North

© 2010 Gensler

Scale

Description

Project Number

Project Name

Seal/Signature

Issue Date & Issue Description By Check

SHEET NOTES

PLOTTING DATE: FILE PATH AND NAME:

NOT FOR CONSTRUCTION

KEY PLAN

LEGEND

# INDICATES SHEET NOTEA00.00

1/4" = 1'-0"

S:\13.7042.430\BIM\Building Model\_User Model Files\Andrea Henderson_137042430_Tampa.rvt6/11/2010 7:09:54 PM

D01.13.B

DEMOLITION PLAN - FACTORY LEVEL 03 EAST

13.7042.430

CLASS V ORG - TAMPA

CHURCH OFSCIENTOLOGYCLASS V ORG - TAMPA1300 East 8th AveTampa, FL 33605

01 PARTIAL-HEIGHT ARCHITECTURALPILASTERS TO BE REMOVED

02 DEMOUNTABLE PARTITION TO BE REMOVED

03 WINDOW WALL TO BE REMOVED

04 MILLWORK TO BE REMOVED

05 MILLWORK TO REMAIN

06 PLUMBING FIXTURE TO BE REMOVED

07 ALL ELECTRICAL DEVICES, FLOOR FINISHES,WALL BASE, CEILING SYSTEMS IN THISROOM/CORRIDOR TO REMAIN

08 CEILING SYSTEM IN THIS ROOM/CORRIDORTO REMAIN

09 HISTORIC METAL CEILING SYSTEM IN THISROOM TO REMAIN

10 WINDOW WALL TO REMAIN

11 SIDELITE TO BE REMOVED

12 SIDELITE TO REMAIN

13 WINDOW TO REMAIN

14 REMOVE WINDOW AND MASONRY BELOWWINDOW OPENING TO BE FLUSH WITHADJACENT SUBFLOOR

15 HISTORIC GUARDRAIL TO REMAIN

16 HISTORIC STAIR TO REMAIN

17 COUNTER AND WALL BELOW TO BEREMOVED

18 CROWN MOULDING IN THIS OFFICE SUITETO BE REMOVED

19 HISTORIC “READER’S PERCH” TO REMAIN

20 SLIDING WALL SYSTEM TO BE REMOVED

21 BRICK MASONRY PILASTERS AND METALSERVICE GATE

22 EDGE OF BRIDGE ABOVE

23 CLERESTORY WINDOW

24 STEPS

25 RAMP

26 CHANGE IN SLAB LEVEL

27 MASONRY WALL

28 PARTIAL HEIGHT BRICK FOUNDATION WALL

29 MASONRY BUTTRESS

30 MASONRY COLUMN

31 MASONRY FOUNDATION AT COLUMN

32 STEEL COLUMN

33 WOOD COLUMN

34 CONCRETE FOUNDATION AT COLUMN

35 RAISED FLOOR SYSTEM TO BE REMOVEDAND SALVAGED

36 MILLWORK TO BE SALVAGED - PLACE ONFLOOR SLAB AFTER REMOVAL OF RAISEDFLOOR SYSTEM

37 REMOVE UPPER CABINET AND PLACE ONFLOOR SLAB IN THIS ROOM

38 OUTLINE OF EXISTING ROOF ABOVE

39 CHILLED WATER LINES TO REMAIN

40 CONTRACTOR TO VERIFY IF ANY STEPSEXIST BELOW RAISED FLOORING AND TOSUBMIT DOCUMENTATION TO ARCHITECT

41 DOOR ABOVE SHOWN DASHED BUTSCHEDULED TO REMAIN

BA

UP

UP

EXISTING WALL TO REMAIN

EXISTING WALL TO BE DEMOLISHED

EXISTING DOOR AND FRAME TO REMAIN

EXISTING DOOR AND FRAME TO BE REMOVEDAND SALVAGED

5S 6S 7S 8S 9S 10S4S3S2S1S

BS

AS

MATCHLINE

/1

D01.21.B

WOMEN'S MEN'S

MECHANICAL ROOM

UTILITY ROOM

A J A C E N T B U I L D I N G - N I C

E X I S T I N G O U T D O O R C O U R T Y A R D - N I C

21A01

22A01

3ELEVATOR

12STAIR

07A01

PORTICON.I.C.

38A01

33A01

34A01

TYP

TYP

MIN

4' - 0" 07A01

04A01

06A01

04A01

06A01

04A01

18A01

MATCHLINE

/1

D01.21.B

20' - 7"

19' - 0"

20' - 10"

11' - 10 1/2" 9' - 11" 9' - 10" 9' - 10" 9' - 10" 9' - 10" 9' - 10 1/2" 9' - 10" 9' - 10" 9' - 10"

Gensler

101 Marietta Street NWSuite 3000Atlanta GA 30303Tel: 404.507.1000

Ref. North

© 2010 Gensler

Scale

Description

Project Number

Project Name

Seal/Signature

Issue Date & Issue Description By Check

SHEET NOTES

PLOTTING DATE: FILE PATH AND NAME:

NOT FOR CONSTRUCTION

KEY PLAN

LEGEND

# INDICATES SHEET NOTEA00.00

1/4" = 1'-0"

S:\13.7042.430\BIM\Building Model\_User Model Files\Andrea Henderson_137042430_Tampa.rvt6/11/2010 7:09:56 PM

D01.21.A

DEMOLITION PLAN - STEMMERY LEVEL 01 WEST

13.7042.430

CLASS V ORG - TAMPA

CHURCH OFSCIENTOLOGYCLASS V ORG - TAMPA1300 East 8th AveTampa, FL 33605

01 PARTIAL-HEIGHT ARCHITECTURALPILASTERS TO BE REMOVED

02 DEMOUNTABLE PARTITION TO BE REMOVED

03 WINDOW WALL TO BE REMOVED

04 MILLWORK TO BE REMOVED

05 MILLWORK TO REMAIN

06 PLUMBING FIXTURE TO BE REMOVED

07 ALL ELECTRICAL DEVICES, FLOOR FINISHES,WALL BASE, CEILING SYSTEMS IN THISROOM/CORRIDOR TO REMAIN

08 CEILING SYSTEM IN THIS ROOM/CORRIDORTO REMAIN

09 HISTORIC METAL CEILING SYSTEM IN THISROOM TO REMAIN

10 WINDOW WALL TO REMAIN

11 SIDELITE TO BE REMOVED

12 SIDELITE TO REMAIN

13 WINDOW TO REMAIN

14 REMOVE WINDOW AND MASONRY BELOWWINDOW OPENING TO BE FLUSH WITHADJACENT SUBFLOOR

15 HISTORIC GUARDRAIL TO REMAIN

16 HISTORIC STAIR TO REMAIN

17 COUNTER AND WALL BELOW TO BEREMOVED

18 CROWN MOULDING IN THIS OFFICE SUITETO BE REMOVED

19 HISTORIC “READER’S PERCH” TO REMAIN

20 SLIDING WALL SYSTEM TO BE REMOVED

21 BRICK MASONRY PILASTERS AND METALSERVICE GATE

22 EDGE OF BRIDGE ABOVE

23 CLERESTORY WINDOW

24 STEPS

25 RAMP

26 CHANGE IN SLAB LEVEL

27 MASONRY WALL

28 PARTIAL HEIGHT BRICK FOUNDATION WALL

29 MASONRY BUTTRESS

30 MASONRY COLUMN

31 MASONRY FOUNDATION AT COLUMN

32 STEEL COLUMN

33 WOOD COLUMN

34 CONCRETE FOUNDATION AT COLUMN

35 RAISED FLOOR SYSTEM TO BE REMOVEDAND SALVAGED

36 MILLWORK TO BE SALVAGED - PLACE ONFLOOR SLAB AFTER REMOVAL OF RAISEDFLOOR SYSTEM

37 REMOVE UPPER CABINET AND PLACE ONFLOOR SLAB IN THIS ROOM

38 OUTLINE OF EXISTING ROOF ABOVE

39 CHILLED WATER LINES TO REMAIN

40 CONTRACTOR TO VERIFY IF ANY STEPSEXIST BELOW RAISED FLOORING AND TOSUBMIT DOCUMENTATION TO ARCHITECT

41 DOOR ABOVE SHOWN DASHED BUTSCHEDULED TO REMAIN

BA

UP

UP

UP

EXISTING WALL TO REMAIN

EXISTING WALL TO BE DEMOLISHED

EXISTING DOOR AND FRAME TO REMAIN

EXISTING DOOR AND FRAME TO BE REMOVEDAND SALVAGED

9S 10S 11S 12S 13S 14S 15S 16S 17S 18S 19S

BS

AS

/1

D01.21.A

35A01

02A01

TYP

STAIR 15

18A01

34A01

33A01

TYP

TYP

36A01

07A01

STAIR 13

ELEV 2

ELECTRICAL ROOM

07A01

24A01

36A01

37A01

02A01

02A01

40A01

01A01 24

A01

40A01

20' - 7"

19' - 0"

20' - 10"

/1

D01.21.A

MATCHLINE

MATCHLINE

9' - 10" 9' - 9" 9' - 10" 9' - 10" 9' - 10" 9' - 11 1/2" 9' - 11" 9' - 10 1/2" 9' - 10 1/2" 11' - 3"

20' - 10"

19' - 0"

20' - 7"

23' - 2"

41A01

Gensler

101 Marietta Street NWSuite 3000Atlanta GA 30303Tel: 404.507.1000

Ref. North

© 2010 Gensler

Scale

Description

Project Number

Project Name

Seal/Signature

Issue Date & Issue Description By Check

SHEET NOTES

PLOTTING DATE: FILE PATH AND NAME:

NOT FOR CONSTRUCTION

KEY PLAN

LEGEND

# INDICATES SHEET NOTEA00.00

1/4" = 1'-0"

S:\13.7042.430\BIM\Building Model\_User Model Files\Andrea Henderson_137042430_Tampa.rvt6/11/2010 7:09:57 PM

D01.21.B

DEMOLITION PLAN - STEMMERY LEVEL 01 EAST

13.7042.430

CLASS V ORG - TAMPA

CHURCH OFSCIENTOLOGYCLASS V ORG - TAMPA1300 East 8th AveTampa, FL 33605

01 PARTIAL-HEIGHT ARCHITECTURALPILASTERS TO BE REMOVED

02 DEMOUNTABLE PARTITION TO BE REMOVED

03 WINDOW WALL TO BE REMOVED

04 MILLWORK TO BE REMOVED

05 MILLWORK TO REMAIN

06 PLUMBING FIXTURE TO BE REMOVED

07 ALL ELECTRICAL DEVICES, FLOOR FINISHES,WALL BASE, CEILING SYSTEMS IN THISROOM/CORRIDOR TO REMAIN

08 CEILING SYSTEM IN THIS ROOM/CORRIDORTO REMAIN

09 HISTORIC METAL CEILING SYSTEM IN THISROOM TO REMAIN

10 WINDOW WALL TO REMAIN

11 SIDELITE TO BE REMOVED

12 SIDELITE TO REMAIN

13 WINDOW TO REMAIN

14 REMOVE WINDOW AND MASONRY BELOWWINDOW OPENING TO BE FLUSH WITHADJACENT SUBFLOOR

15 HISTORIC GUARDRAIL TO REMAIN

16 HISTORIC STAIR TO REMAIN

17 COUNTER AND WALL BELOW TO BEREMOVED

18 CROWN MOULDING IN THIS OFFICE SUITETO BE REMOVED

19 HISTORIC “READER’S PERCH” TO REMAIN

20 SLIDING WALL SYSTEM TO BE REMOVED

21 BRICK MASONRY PILASTERS AND METALSERVICE GATE

22 EDGE OF BRIDGE ABOVE

23 CLERESTORY WINDOW

24 STEPS

25 RAMP

26 CHANGE IN SLAB LEVEL

27 MASONRY WALL

28 PARTIAL HEIGHT BRICK FOUNDATION WALL

29 MASONRY BUTTRESS

30 MASONRY COLUMN

31 MASONRY FOUNDATION AT COLUMN

32 STEEL COLUMN

33 WOOD COLUMN

34 CONCRETE FOUNDATION AT COLUMN

35 RAISED FLOOR SYSTEM TO BE REMOVEDAND SALVAGED

36 MILLWORK TO BE SALVAGED - PLACE ONFLOOR SLAB AFTER REMOVAL OF RAISEDFLOOR SYSTEM

37 REMOVE UPPER CABINET AND PLACE ONFLOOR SLAB IN THIS ROOM

38 OUTLINE OF EXISTING ROOF ABOVE

39 CHILLED WATER LINES TO REMAIN

40 CONTRACTOR TO VERIFY IF ANY STEPSEXIST BELOW RAISED FLOORING AND TOSUBMIT DOCUMENTATION TO ARCHITECT

41 DOOR ABOVE SHOWN DASHED BUTSCHEDULED TO REMAIN

BA

5S 6S 7S 8S 9S 10S4S3S2S1S

BS

AS

/1

D01.22.B

E X I S T I N G B U I L D I N G - N I C

E X I S T I N G B R I D G E - N I C

ELECTRICALROOM

MECHANICALROOM

07A01

07A01

04A01

06A01

DN DN

ELEV 3

ROOF BELOWN.I.C.

07A01

07A01

33A01

33A01 TYP

MEN'SWOMEN'S

MIN

5' - 0"

DN

DN

STAIR 12

MATCHLINE

MATCHLINE

/1

D01.22.B

11' - 9" 9' - 11" 9' - 10" 9' - 10" 9' - 10" 9' - 10" 9' - 10 1/2" 9' - 10" 9' - 10"

20' - 7 1/2"

19' - 0"

20' - 8 1/2"

EXISTING WALL TO REMAIN

EXISTING WALL TO BE DEMOLISHED

EXISTING DOOR AND FRAME TO REMAIN

EXISTING DOOR AND FRAME TO BE REMOVEDAND SALVAGED

Gensler

101 Marietta Street NWSuite 3000Atlanta GA 30303Tel: 404.507.1000

Ref. North

© 2010 Gensler

Scale

Description

Project Number

Project Name

Seal/Signature

Issue Date & Issue Description By Check

SHEET NOTES

PLOTTING DATE: FILE PATH AND NAME:

NOT FOR CONSTRUCTION

KEY PLAN

LEGEND

# INDICATES SHEET NOTEA00.00

1/4" = 1'-0"

S:\13.7042.430\BIM\Building Model\_User Model Files\Andrea Henderson_137042430_Tampa.rvt6/11/2010 7:09:58 PM

D01.22.A

DEMOLITION PLAN - STEMMERY LEVEL 02 WEST

13.7042.430

CLASS V ORG - TAMPA

CHURCH OFSCIENTOLOGYCLASS V ORG - TAMPA1300 East 8th AveTampa, FL 33605

01 PARTIAL-HEIGHT ARCHITECTURALPILASTERS TO BE REMOVED

02 DEMOUNTABLE PARTITION TO BE REMOVED

03 WINDOW WALL TO BE REMOVED

04 MILLWORK TO BE REMOVED

05 MILLWORK TO REMAIN

06 PLUMBING FIXTURE TO BE REMOVED

07 ALL ELECTRICAL DEVICES, FLOOR FINISHES,WALL BASE, CEILING SYSTEMS IN THISROOM/CORRIDOR TO REMAIN

08 CEILING SYSTEM IN THIS ROOM/CORRIDORTO REMAIN

09 HISTORIC METAL CEILING SYSTEM IN THISROOM TO REMAIN

10 WINDOW WALL TO REMAIN

11 SIDELITE TO BE REMOVED

12 SIDELITE TO REMAIN

13 WINDOW TO REMAIN

14 REMOVE WINDOW AND MASONRY BELOWWINDOW OPENING TO BE FLUSH WITHADJACENT SUBFLOOR

15 HISTORIC GUARDRAIL TO REMAIN

16 HISTORIC STAIR TO REMAIN

17 COUNTER AND WALL BELOW TO BEREMOVED

18 CROWN MOULDING IN THIS OFFICE SUITETO BE REMOVED

19 HISTORIC “READER’S PERCH” TO REMAIN

20 SLIDING WALL SYSTEM TO BE REMOVED

21 BRICK MASONRY PILASTERS AND METALSERVICE GATE

22 EDGE OF BRIDGE ABOVE

23 CLERESTORY WINDOW

24 STEPS

25 RAMP

26 CHANGE IN SLAB LEVEL

27 MASONRY WALL

28 PARTIAL HEIGHT BRICK FOUNDATION WALL

29 MASONRY BUTTRESS

30 MASONRY COLUMN

31 MASONRY FOUNDATION AT COLUMN

32 STEEL COLUMN

33 WOOD COLUMN

34 CONCRETE FOUNDATION AT COLUMN

35 RAISED FLOOR SYSTEM TO BE REMOVEDAND SALVAGED

36 MILLWORK TO BE SALVAGED - PLACE ONFLOOR SLAB AFTER REMOVAL OF RAISEDFLOOR SYSTEM

37 REMOVE UPPER CABINET AND PLACE ONFLOOR SLAB IN THIS ROOM

38 OUTLINE OF EXISTING ROOF ABOVE

39 CHILLED WATER LINES TO REMAIN

40 CONTRACTOR TO VERIFY IF ANY STEPSEXIST BELOW RAISED FLOORING AND TOSUBMIT DOCUMENTATION TO ARCHITECT

41 DOOR ABOVE SHOWN DASHED BUTSCHEDULED TO REMAIN

BA

DN

DN

10S 11S 12S 13S 14S 15S 16S 17S 18S 19S

BS

AS

MATCHLINE

/1

D01.22.A

MAINTENANCEROOM

STAIR 13

ELEV 2

33A01

TYP

19A01

MIN

4' - 8"

MATCHLINE

/1

D01.22.A

20' - 7 1/2"

19' - 0"

20' - 8 1/2"

20' - 8 1/2"

19' - 0"

20' - 7 1/2"

23' - 1"

9' - 10" 9' - 9" 9' - 10" 9' - 10" 9' - 10" 9' - 11 1/2" 9' - 11" 9' - 10 1/2" 9' - 10 1/2" 11' - 4"

07A01

EXISTING WALL TO REMAIN

EXISTING WALL TO BE DEMOLISHED

EXISTING DOOR AND FRAME TO REMAIN

EXISTING DOOR AND FRAME TO BE REMOVEDAND SALVAGED

Gensler

101 Marietta Street NWSuite 3000Atlanta GA 30303Tel: 404.507.1000

Ref. North

© 2010 Gensler

Scale

Description

Project Number

Project Name

Seal/Signature

Issue Date & Issue Description By Check

SHEET NOTES

PLOTTING DATE: FILE PATH AND NAME:

NOT FOR CONSTRUCTION

KEY PLAN

LEGEND

# INDICATES SHEET NOTEA00.00

1/4" = 1'-0"

S:\13.7042.430\BIM\Building Model\_User Model Files\Andrea Henderson_137042430_Tampa.rvt6/11/2010 7:10:00 PM

D01.22.B

DEMOLITION PLAN - STEMMERY LEVEL 02 EAST

13.7042.430

CLASS V ORG - TAMPA

CHURCH OFSCIENTOLOGYCLASS V ORG - TAMPA1300 East 8th AveTampa, FL 33605

01 PARTIAL-HEIGHT ARCHITECTURALPILASTERS TO BE REMOVED

02 DEMOUNTABLE PARTITION TO BE REMOVED

03 WINDOW WALL TO BE REMOVED

04 MILLWORK TO BE REMOVED

05 MILLWORK TO REMAIN

06 PLUMBING FIXTURE TO BE REMOVED

07 ALL ELECTRICAL DEVICES, FLOOR FINISHES,WALL BASE, CEILING SYSTEMS IN THISROOM/CORRIDOR TO REMAIN

08 CEILING SYSTEM IN THIS ROOM/CORRIDORTO REMAIN

09 HISTORIC METAL CEILING SYSTEM IN THISROOM TO REMAIN

10 WINDOW WALL TO REMAIN

11 SIDELITE TO BE REMOVED

12 SIDELITE TO REMAIN

13 WINDOW TO REMAIN

14 REMOVE WINDOW AND MASONRY BELOWWINDOW OPENING TO BE FLUSH WITHADJACENT SUBFLOOR

15 HISTORIC GUARDRAIL TO REMAIN

16 HISTORIC STAIR TO REMAIN

17 COUNTER AND WALL BELOW TO BEREMOVED

18 CROWN MOULDING IN THIS OFFICE SUITETO BE REMOVED

19 HISTORIC “READER’S PERCH” TO REMAIN

20 SLIDING WALL SYSTEM TO BE REMOVED

21 BRICK MASONRY PILASTERS AND METALSERVICE GATE

22 EDGE OF BRIDGE ABOVE

23 CLERESTORY WINDOW

24 STEPS

25 RAMP

26 CHANGE IN SLAB LEVEL

27 MASONRY WALL

28 PARTIAL HEIGHT BRICK FOUNDATION WALL

29 MASONRY BUTTRESS

30 MASONRY COLUMN

31 MASONRY FOUNDATION AT COLUMN

32 STEEL COLUMN

33 WOOD COLUMN

34 CONCRETE FOUNDATION AT COLUMN

35 RAISED FLOOR SYSTEM TO BE REMOVEDAND SALVAGED

36 MILLWORK TO BE SALVAGED - PLACE ONFLOOR SLAB AFTER REMOVAL OF RAISEDFLOOR SYSTEM

37 REMOVE UPPER CABINET AND PLACE ONFLOOR SLAB IN THIS ROOM

38 OUTLINE OF EXISTING ROOF ABOVE

39 CHILLED WATER LINES TO REMAIN

40 CONTRACTOR TO VERIFY IF ANY STEPSEXIST BELOW RAISED FLOORING AND TOSUBMIT DOCUMENTATION TO ARCHITECT

41 DOOR ABOVE SHOWN DASHED BUTSCHEDULED TO REMAIN

BA

5S 6S 7S 8S 9S 10S4S3S2S1S

BS

AS

MATCHLINE

/1

D01.23.B

STAIR 12

DN

DN

06A01

04A01

ELECTRICALROOM

MECHANICALROOM

07A01

07A01

33A01

TYP

MATCHLINE

/1

D01.23.B

11' - 9" 9' - 11" 9' - 10" 9' - 10" 9' - 10" 9' - 10" 9' - 10 1/2" 9' - 10" 9' - 10"

20' - 8 1/2"

19' - 0"

20' - 7 1/2"

R O O F B E L O W - N I C

EXISTING WALL TO REMAIN

EXISTING WALL TO BE DEMOLISHED

EXISTING DOOR AND FRAME TO REMAIN

EXISTING DOOR AND FRAME TO BE REMOVEDAND SALVAGED

Gensler

101 Marietta Street NWSuite 3000Atlanta GA 30303Tel: 404.507.1000

Ref. North

© 2010 Gensler

Scale

Description

Project Number

Project Name

Seal/Signature

Issue Date & Issue Description By Check

SHEET NOTES

PLOTTING DATE: FILE PATH AND NAME:

NOT FOR CONSTRUCTION

KEY PLAN

LEGEND

# INDICATES SHEET NOTEA00.00

1/4" = 1'-0"

S:\13.7042.430\BIM\Building Model\_User Model Files\Andrea Henderson_137042430_Tampa.rvt6/11/2010 7:10:01 PM

D01.23.A

DEMOLITION PLAN - STEMMERY LEVEL 03 WEST

13.7042.430

CLASS V ORG - TAMPA

CHURCH OFSCIENTOLOGYCLASS V ORG - TAMPA1300 East 8th AveTampa, FL 33605

01 PARTIAL-HEIGHT ARCHITECTURALPILASTERS TO BE REMOVED

02 DEMOUNTABLE PARTITION TO BE REMOVED

03 WINDOW WALL TO BE REMOVED

04 MILLWORK TO BE REMOVED

05 MILLWORK TO REMAIN

06 PLUMBING FIXTURE TO BE REMOVED

07 ALL ELECTRICAL DEVICES, FLOOR FINISHES,WALL BASE, CEILING SYSTEMS IN THISROOM/CORRIDOR TO REMAIN

08 CEILING SYSTEM IN THIS ROOM/CORRIDORTO REMAIN

09 HISTORIC METAL CEILING SYSTEM IN THISROOM TO REMAIN

10 WINDOW WALL TO REMAIN

11 SIDELITE TO BE REMOVED

12 SIDELITE TO REMAIN

13 WINDOW TO REMAIN

14 REMOVE WINDOW AND MASONRY BELOWWINDOW OPENING TO BE FLUSH WITHADJACENT SUBFLOOR

15 HISTORIC GUARDRAIL TO REMAIN

16 HISTORIC STAIR TO REMAIN

17 COUNTER AND WALL BELOW TO BEREMOVED

18 CROWN MOULDING IN THIS OFFICE SUITETO BE REMOVED

19 HISTORIC “READER’S PERCH” TO REMAIN

20 SLIDING WALL SYSTEM TO BE REMOVED

21 BRICK MASONRY PILASTERS AND METALSERVICE GATE

22 EDGE OF BRIDGE ABOVE

23 CLERESTORY WINDOW

24 STEPS

25 RAMP

26 CHANGE IN SLAB LEVEL

27 MASONRY WALL

28 PARTIAL HEIGHT BRICK FOUNDATION WALL

29 MASONRY BUTTRESS

30 MASONRY COLUMN

31 MASONRY FOUNDATION AT COLUMN

32 STEEL COLUMN

33 WOOD COLUMN

34 CONCRETE FOUNDATION AT COLUMN

35 RAISED FLOOR SYSTEM TO BE REMOVEDAND SALVAGED

36 MILLWORK TO BE SALVAGED - PLACE ONFLOOR SLAB AFTER REMOVAL OF RAISEDFLOOR SYSTEM

37 REMOVE UPPER CABINET AND PLACE ONFLOOR SLAB IN THIS ROOM

38 OUTLINE OF EXISTING ROOF ABOVE

39 CHILLED WATER LINES TO REMAIN

40 CONTRACTOR TO VERIFY IF ANY STEPSEXIST BELOW RAISED FLOORING AND TOSUBMIT DOCUMENTATION TO ARCHITECT

41 DOOR ABOVE SHOWN DASHED BUTSCHEDULED TO REMAIN

BA

DN

10S 11S 12S 13S 14S 15S 16S 17S 18S 19S

BS

AS

/1

D01.23.A

33A01

TYP

STAIR 13

ELEV 2

ROOF BELOWN.I.C.

9' - 10" 9' - 9" 9' - 10" 9' - 10" 9' - 10" 9' - 11 1/2" 9' - 11" 9' - 10 1/2" 9' - 10 1/2" 11' - 4"

20' - 8 1/2"

19' - 0"

20' - 7 1/2"

MATCHLINE

/1

D01.23.A

MATCHLINE

20' - 8 1/2"

19' - 0"

20' - 7 1/2"

EXISTING WALL TO REMAIN

EXISTING WALL TO BE DEMOLISHED

EXISTING DOOR AND FRAME TO REMAIN

EXISTING DOOR AND FRAME TO BE REMOVEDAND SALVAGED

Gensler

101 Marietta Street NWSuite 3000Atlanta GA 30303Tel: 404.507.1000

Ref. North

© 2010 Gensler

Scale

Description

Project Number

Project Name

Seal/Signature

Issue Date & Issue Description By Check

SHEET NOTES

PLOTTING DATE: FILE PATH AND NAME:

NOT FOR CONSTRUCTION

KEY PLAN

LEGEND

# INDICATES SHEET NOTEA00.00

1/4" = 1'-0"

S:\13.7042.430\BIM\Building Model\_User Model Files\Andrea Henderson_137042430_Tampa.rvt6/11/2010 7:10:02 PM

D01.23.B

DEMOLITION PLAN - STEMMERY LEVEL 03 EAST

13.7042.430

CLASS V ORG - TAMPA

CHURCH OFSCIENTOLOGYCLASS V ORG - TAMPA1300 East 8th AveTampa, FL 33605

01 PARTIAL-HEIGHT ARCHITECTURALPILASTERS TO BE REMOVED

02 DEMOUNTABLE PARTITION TO BE REMOVED

03 WINDOW WALL TO BE REMOVED

04 MILLWORK TO BE REMOVED

05 MILLWORK TO REMAIN

06 PLUMBING FIXTURE TO BE REMOVED

07 ALL ELECTRICAL DEVICES, FLOOR FINISHES,WALL BASE, CEILING SYSTEMS IN THISROOM/CORRIDOR TO REMAIN

08 CEILING SYSTEM IN THIS ROOM/CORRIDORTO REMAIN

09 HISTORIC METAL CEILING SYSTEM IN THISROOM TO REMAIN

10 WINDOW WALL TO REMAIN

11 SIDELITE TO BE REMOVED

12 SIDELITE TO REMAIN

13 WINDOW TO REMAIN

14 REMOVE WINDOW AND MASONRY BELOWWINDOW OPENING TO BE FLUSH WITHADJACENT SUBFLOOR

15 HISTORIC GUARDRAIL TO REMAIN

16 HISTORIC STAIR TO REMAIN

17 COUNTER AND WALL BELOW TO BEREMOVED

18 CROWN MOULDING IN THIS OFFICE SUITETO BE REMOVED

19 HISTORIC “READER’S PERCH” TO REMAIN

20 SLIDING WALL SYSTEM TO BE REMOVED

21 BRICK MASONRY PILASTERS AND METALSERVICE GATE

22 EDGE OF BRIDGE ABOVE

23 CLERESTORY WINDOW

24 STEPS

25 RAMP

26 CHANGE IN SLAB LEVEL

27 MASONRY WALL

28 PARTIAL HEIGHT BRICK FOUNDATION WALL

29 MASONRY BUTTRESS

30 MASONRY COLUMN

31 MASONRY FOUNDATION AT COLUMN

32 STEEL COLUMN

33 WOOD COLUMN

34 CONCRETE FOUNDATION AT COLUMN

35 RAISED FLOOR SYSTEM TO BE REMOVEDAND SALVAGED

36 MILLWORK TO BE SALVAGED - PLACE ONFLOOR SLAB AFTER REMOVAL OF RAISEDFLOOR SYSTEM

37 REMOVE UPPER CABINET AND PLACE ONFLOOR SLAB IN THIS ROOM

38 OUTLINE OF EXISTING ROOF ABOVE

39 CHILLED WATER LINES TO REMAIN

40 CONTRACTOR TO VERIFY IF ANY STEPSEXIST BELOW RAISED FLOORING AND TOSUBMIT DOCUMENTATION TO ARCHITECT

41 DOOR ABOVE SHOWN DASHED BUTSCHEDULED TO REMAIN

BA