15
Chun-Cheng Lin Medical Engineering & Physics 30 (2008) 834–842, ELSEVIER Presenter Chia-Cheng Chen

Chun-Cheng Lin Medical Engineering & Physics 30 (2008) 834–842, ELSEVIER

  • Upload
    yonah

  • View
    49

  • Download
    1

Embed Size (px)

DESCRIPTION

Enhancement of accuracy and reproducibility of parametric modeling for estimating abnormal intra-QRS potentials in signal-averaged electrocardiograms. Chun-Cheng Lin Medical Engineering & Physics 30 (2008) 834–842, ELSEVIER. Presenter Chia-Cheng Chen. Outline. Introduction - PowerPoint PPT Presentation

Citation preview

Page 1: Chun-Cheng Lin Medical Engineering & Physics 30 (2008) 834–842, ELSEVIER

Chun-Cheng Lin

Medical Engineering & Physics 30 (2008) 834–842, ELSEVIER

Presenter Chia-Cheng Chen

Page 2: Chun-Cheng Lin Medical Engineering & Physics 30 (2008) 834–842, ELSEVIER

Introduction Materials and methods Results Conclusions

Page 3: Chun-Cheng Lin Medical Engineering & Physics 30 (2008) 834–842, ELSEVIER

Enhance the accuracy and reproducibility of parametric modeling in the discrete cosine transform (DCT) domain for the estimation of abnormal intra-QRS potentials (AIQP).

100 independent sets of white noise to simulate the broadband, unpredictable AIQP.

Page 4: Chun-Cheng Lin Medical Engineering & Physics 30 (2008) 834–842, ELSEVIER

The estimated AIQP has obvious estimation errors in the low-frequency DCT coefficients.

Eliminates some low-frequency DCT coefficients with estimation errors to define a high-frequency AIQP parameter.

Page 5: Chun-Cheng Lin Medical Engineering & Physics 30 (2008) 834–842, ELSEVIER

Materials◦ Group I (the normal group) consisted of 42 normal

Taiwanese (20 men and 22 women, aged 58±14 years old)

◦ Group II (the VT group) consisted of 30 patients (15 men and 15 women, aged 63±16 years old)

Page 6: Chun-Cheng Lin Medical Engineering & Physics 30 (2008) 834–842, ELSEVIER
Page 7: Chun-Cheng Lin Medical Engineering & Physics 30 (2008) 834–842, ELSEVIER

ARMA(2M,2M)

Page 8: Chun-Cheng Lin Medical Engineering & Physics 30 (2008) 834–842, ELSEVIER

The cross-correlation coefficient p between the original signal x(n) and the QRS estimate )(s n

Page 9: Chun-Cheng Lin Medical Engineering & Physics 30 (2008) 834–842, ELSEVIER
Page 10: Chun-Cheng Lin Medical Engineering & Physics 30 (2008) 834–842, ELSEVIER

Definition of the high-frequency AIQP parameter

q% indicates the percentage of the total DCT coeffi-Cients

Page 11: Chun-Cheng Lin Medical Engineering & Physics 30 (2008) 834–842, ELSEVIER

Used 100 independent sets of normally distributed white noise with zero mean to simulate the broad-band, unpredictable AIQP.

The AIQP was estimated under different values of q% (100%,90% and 80%) and magnitudes (AIQP l(q%) = 0–10 V).

Page 12: Chun-Cheng Lin Medical Engineering & Physics 30 (2008) 834–842, ELSEVIER
Page 13: Chun-Cheng Lin Medical Engineering & Physics 30 (2008) 834–842, ELSEVIER
Page 14: Chun-Cheng Lin Medical Engineering & Physics 30 (2008) 834–842, ELSEVIER
Page 15: Chun-Cheng Lin Medical Engineering & Physics 30 (2008) 834–842, ELSEVIER

This study has successfully demonstrated that the high-frequency AIQP parameter, while neglecting some low-frequency DCT coefficients with estimation errors.