Instructions to Requesting Engineer New Chiller Bids: PG&E CAP Chillers: Be sure to delete this worksheet and constant and variable flow condenser water scenarios. You will need to customize it for your particular application by deleting or hiding extraneous rows and worksheets. should delete fields like Yr Installed. You should also delete the Variable CW Flow worksheets since DOE-2 can only evaluate constant CW flow scenarios. as "Delivery Lead Time", "Fouling Factor" and the Constant CW Flow worksheets. CAP chillers are evaluated using a simulation tool developed by Mark Hydeman which has the ability to model variable condenser water flows.

Chiller Performance Template - Air Cooled

Embed Size (px)

DESCRIPTION

Chiller Performance Template - Air Cooled

Citation preview

Delete MeInstructions to Requesting EngineerThis spreadsheet is generic. It covers both new and existing chillers and constant and variable flow condenser water scenarios. You will need to customize it for your particular application by deleting or hiding extraneous rows and worksheets.New Chiller Bids:For example, for a new chiller bid to be evaluated with DOE-2 you should delete fields like Yr Installed. You should also delete the Variable CW Flow worksheets since DOE-2 can only evaluate constant CW flow scenarios.PG&E CAP Chillers:For existing chillers in the CAP program you should delete fields such as "Delivery Lead Time", "Fouling Factor" and the Constant CW Flow worksheets. CAP chillers are evaluated using a simulation tool developed by Mark Hydeman which has the ability to model variable condenser water flows.Be sure to delete this worksheet

Start HereChiller Performance FormComplete this worksheet before completing Part Load and Full Load worksheetsFill out all yellow-highlighted cells. White fields are fixed. Gray fields are calculated automaticallyDo not include ARI tolerances.GeneralOption:Manufacturer:Model:Compressor type:Refrigerant type:Refrigerant weight (lbs):Variable speed drive (Y/N)Delivery lead time (weeks):Operating ConstraintsMaximum CHW flow rate (GPM):Minimum CHW flow rate (GPM):Capacity (% of design capacity) below which hot-gas bypass operates (set to 0 if no HGBP)Minimum Entering OAT (F):Voltage/phase:480/3Design ConditionsEvaporatorCondenserCHW fouling factor:0.0001CW fouling factor:0.00025Leaving CHWST (F):Entering OAT (F):Entering CHWRT (F):Design CHW flow (GPM):CHW pressure drop (ft):Evaporator passes:Evap. Refrigerant Temperature (F)Cond. Refrigerant Temperature (F)Design kW (w/o ARI Tolerance):Full load amps:Design capacity (tons):0.0Design kW/ton:0.000For existing chillers complete the following information:Serial #Customer/LocationYear InstalledWidest expected CHWST reset range (F)20

If more complex minimum temperature equation is required, enter typical minimum value here and explain in footnote below how control system would determine minimum CWST or CWRTWarmest temperature above design CHWST expected due to CHWST setpoint reset

Full Load Full Load ConditionsComplete the "Start Here" worksheet before completing this worksheet. Fill out all yellow-highlighted fields. The following data shall be at the proposed design conditions entered above except where noted. The capacity and power inputs are for unmodulated operation (no power or current limits with all capacity control devices fully open). Do not include ARI tolerance in capacity or power listed.EvaporatorCondenserUnloadingCapacityPowerLeaving TempEntering TempCHW flowEntering Temp%tonskWCHWST (F)CHWRT (F)gpmOAT (F)100%00.00.00.0100%00.00.00.0100%00.00.00.0100%00.00.00.0100%00.00.00.0100%50.00.00.0100%50.00.00.0100%50.00.00.0100%50.00.00.0100%50.00.00.0100%100.00.00.0100%100.00.00.0100%100.00.00.0100%100.00.00.0100%100.00.00.0100%150.00.00.0100%150.00.00.0100%150.00.00.0100%150.00.00.0100%150.00.00.0100%200.00.00.0100%200.00.00.0100%200.00.00.0100%200.00.00.0100%200.00.00.0

Min =Min =Min =Min =Min =Min =Min =Min =Min =Only change this value if it is below min allowed at these conditionsOnly change this value if it is below min allowed at these conditionsOnly change this value if it is below min allowed at these conditionsOnly change this value if it is below min allowed at these conditionsMin =Min =Only change this value if it is below min allowed at these conditions

Part LoadPart Load ConditionsComplete the "Start Here" worksheet before completing this worksheet. Fill out all yellow-highlighted fields. The following data shall be at the proposed design conditions entered on the "Start Here" worksheet except where noted. Do not include ARI tolerance in capacity or power listed. If the calculated capacity is below minimum capacity, override this field and enter the minimum capacity.EvaporatorCondenserPercentCapacityPowerExitEnteringCHW flowEnteringof DesigntonskWCHWST (F)CHWRT (F)gpmOAT (F)Constant OAT0%0.0000.00.00.00%0.000.00.00.00%0.000.00.00.00%0.000.00.00.00%0.000.00.00.00%0.000.00.00.00%0.000.00.00.00%0.000.00.00.00%0.000.00.00.00%0.000.00.00.0With OAT Relief0%0.000.00.00.00%0.000.00.00.00%0.000.00.00.00%0.000.00.00.00%0.000.00.00.00%0.000.00.00.00%0.000.00.00.00%0.000.00.00.00%0.000.00.00.0

You may enter different capacity values if it is difficult to get your software to achieve the exact capacity without ARI tolerances.If calculated value is below minimum capacity, override this field and enter the minimum capacityOnly change this value if it is below min allowed at these conditionsOnly change this value if it is below min allowed at these conditionsOnly change this value if it is below min allowed at these conditionsOnly change this value if it is below min allowed at these conditionsOnly change this value if it is below min allowed at these conditionsIf calculated value is below minimum capacity, override this field and enter the minimum capacityIf calculated value is below minimum capacity, override this field and enter the minimum capacityIf calculated value is below minimum capacity, override this field and enter the minimum capacity