1
CHEMICAL CLEAN OF IHI BOILERS PROJECT The water-wall sections of IHI boilers at power stations are required to be periodically cleaned to remove metal build-up including magnetite and copper deposits. This is typically performed at five year intervals for each boiler. The chemical clean process is around the clock, and typically takes four days. CHEMICAL CIRCULATION Verico’s mechanical testing team are responsible for inducing and controlling chemical circulation during boiler cleans. IHI boilers are designed to work on the principals of natural circulation and are not fitted with circulation pumps. Verico has developed a method which induces circulation in the water-wall sections of the boiler by injecting gas into each downcomer. This creates a differential in liquid densities in various sections of the water-wall system which induces the circulation. The flow in each downcomer is monitored using ultrasonic flow measurement equipment, and controlled by modulating the gas flow. PRODUCTS AND SERVICES PROVIDED Engineering support and coordination Provision, installation and removal for all temporary equipment 24 hour monitoring and control of flows OUTCOME Verico’s services in boiler chemical cleaning have been used for several decades in the Australian industry to increase coal fired boiler life and thermal efficiency. LOCATION: Coal fired power stations across NSW and QLD PROJECT: Boiler chemical clean of IHI boilers in NSW coal fired power stations and various QLD sites Flow head installation on boiler downcorners verico.com.au

CHEMICAL CLEAN OF IHI BOILERS - verico.com.au

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

CHEMICAL CLEAN OF IHI BOILERS

PROJECTThe water-wall sections of IHI boilers at power stations are required to be periodically cleaned to remove metal build-up including magnetite and copper deposits. This is typically performed at five year intervals for each boiler. The chemical clean process is around the clock, and typically takes four days.

CHEMICAL CIRCULATIONVerico’s mechanical testing team are responsible for inducing and controlling chemical circulation during boiler cleans.

IHI boilers are designed to work on the principals of natural circulation and are not fitted with circulation pumps. Verico has developed a method which induces circulation in the water-wall sections of the boiler by injecting gas into each downcomer. This creates a differential in liquid densities in various sections of the water-wall system which induces the circulation.

The flow in each downcomer is monitored using ultrasonic flow measurement equipment, and controlled by modulating the gas flow.

PRODUCTS AND SERVICES PROVIDED• Engineering support and

coordination

• Provision, installation and removal for all temporary equipment

• 24 hour monitoring and control of flows

OUTCOMEVerico’s services in boiler chemical cleaning have been used for several decades in the Australian industry to increase coal fired boiler life and thermal efficiency.

LOCATION: Coal fired power stations across NSW and QLD

PROJECT:Boiler chemical clean of IHI boilers in NSW coal fired power stations and various QLD sites

Flow head installation on boiler downcorners

verico.com.au