Check SoftwareCommissioning Quality
8/14/2019 Check Software Commissioning Quality(RTN600)
2/16
CONTENT
Software Quality Standard List
Quality Checking
8/14/2019 Check Software Commissioning Quality(RTN600)
3/16
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 3
Software Quality Standard ListItem Result
1 Check ODU received power value whether match with the plan.
2 Check ODU TX power value whether match the plan
3 Check ODU TX and RX frequency whether match the plan
4 Check IF working mode whether match the plan
5 Check 1+1 configuration
6 Check 1+1 switch state
7 Check NE ID and name setting whether match the plan
8 Check NE time whether synchronous with computer time
9 Check NE synchronous clock configuration
10 Check performance monitor state whether enabled
11 Check current and history alarm whether there are abnormal alarms
8/14/2019 Check Software Commissioning Quality(RTN600)
4/16
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 4
1. Check ODU received power value whether match
with the plan.
Plan Document
The actual Rx Power value should within the plan designed receive value range accordingto the customers requirement.
8/14/2019 Check Software Commissioning Quality(RTN600)
5/16
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 5
2. Check ODU TX power value whether match the
plan.
Plan Document
The setting Tx Power value should equal to the plan designed transmit value.
The acceptablevalue:
[25.5]
8/14/2019 Check Software Commissioning Quality(RTN600)
6/16
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 6
3. Check ODU TX and RX frequency whether match
the plan.
Plan Document
The Tx Frequency and actual Tx Frequency should equal to the local site plan designed TxFrequency.
8/14/2019 Check Software Commissioning Quality(RTN600)
7/16
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 7
4. Check IF working mode whether match the plan.
Plan Document
The IF Mode should be the same as the plan document.
8/14/2019 Check Software Commissioning Quality(RTN600)
8/16
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 8
5. Check 1+1 configuration.
IF 1+1 configuration should correspond with the link design.
8/14/2019 Check Software Commissioning Quality(RTN600)
9/16
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 9
6. Check 1+1 switch state.
8/14/2019 Check Software Commissioning Quality(RTN600)
10/16
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 10
7. Check NE ID and name setting whether match the
plan.
8/14/2019 Check Software Commissioning Quality(RTN600)
11/16
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 11
8. Check NE time whether synchronous with
computer time. The NE currently time should be synchronous with your computer clock, and synchronous
mode is NM.
The Same
8/14/2019 Check Software Commissioning Quality(RTN600)
12/16
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 12
9. Check NE synchronous clock configuration.
For RTN 620/610, it is necessary to configure synchronous clock.
8/14/2019 Check Software Commissioning Quality(RTN600)
13/16
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 13
9. Check NE synchronous clock configuration.
RTN 620/610 RTN 620/610
Internal InternalPriority
Priority
5-IF 5-IF
5-IF;
Internal
5-IF;
Internal
Typical mistakes:
8/14/2019 Check Software Commissioning Quality(RTN600)
14/16
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 14
10. Check performance monitor state whether
enabled.
State: Enable. State: Enable.
Check on the setting of enabling performance monitor, which is required to be enabled.
8/14/2019 Check Software Commissioning Quality(RTN600)
15/16
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 15
11. Check current and history alarm whether there
are abnormal alarms.
Browse current alarm, cant exist critical and abnormal alarm. Browse history alarm , cant exist critical and abnormal alarm during normal running time.
For cant handle alarm, please save it and require help.