Upload
others
View
7
Download
0
Embed Size (px)
Citation preview
Challenger 22i remote PC-Terminal
aPPlICaTIOnS
PharMaCeUTICal
InDUSTrY
CheMICal
InDUSTrY
OIl & gaS aUTOMOBIle
PrODUCTIOn
WaSTe WaTer
TreaTMenT PlanT
COal FIreD
POWer PlanT
InCIneraTIOn
PlanT
OTher
PrOCeSSeS
CerTIFICaTeS
aTex IeCex
tested by:
• Intrinsicallysafecertifiedcomponentsforoperationandvisualization
• Modularconfiguration
• Trouble-freePChardwarechangesandsoftwareupdates
• AmbientTemperature-10°Cto+50°C
• Lowinstallationcosts
• Excellentpicturequality
• Savingsofsoftwarecostsbycascadingupto4CHALLENGERterminalstoonePC
• Upgradekitalsoavailableforindustrialversion
BeneFITS
SaleS OFFICeS
geCMa SerVICeAllproductinformation/technicaldatasheets/drawingsandaconfigurationtooltooptimizeyourhuman-machineinterfacecanbefoundat:www.GECMA.com
www.gecma.com e-mail:[email protected]
Headquarters GeCMa Components GmbH, Heisenbergstrasse 26-40, d-50169 Kerpen, Gemany. tel: +49 2237 6996-0 Fax: +49 2237 6996-99
Configurator Products
News SupportTechnicaldrawings
Callsreturnedwithin24hours
Offersmadewithin48hours
Fastdeliverytime
ConfigureyourTerminal at www.GECMA.com
Technicalchangesreserved.EffectivefromFebruary2012
ZL-B-CHA
L22iKIT-EN-0212
AUSTRALIAMTLInstrumentsPty,CooperElectrical,205-209WoodparkRoad,POBox2577,Smithfield,NSW2164,Australia
Tel:+611300308374Fax:+611300308463E-mail:[email protected]
CHINACooperElectric(Shanghai)Co.Ltd.Room2001,ChinaLifeTower,16ChaoYangMenWaiStreet,ChaoYangDistrict,Beijing,China100020
Tel:+861059800288Fax:+861085625725E-mail:[email protected]
FRANCEMTLInstrumentssarl,LesCarrésduParc10ruedesRosiéristes,69410ChampagneauMontd’OrFrance
Tel:+33(0)478649832Fax:+33(0)478357941E-mail:[email protected]
GERMANYMTLInstrumentsGmbH,AnderGümpgesbrücke17D-41564Kaarst,Germany
Tel:+49(0)2131718930Fax:+49(0)21317189333E-mail:[email protected]
INDIAMTLIndia,No.36,NehruStreetOffOldMahabalipuramRoadSholinganallur,Chennai-600119,India
Tel:+91(0)4424501660/24501857Fax:+91(0)4424501463E-mail:[email protected]
ITALYMTLItaliasrl,ViaCantù11I-20092CiniselloBalsamoMI,Italy
Tel:+39(0)261802011Fax:+39(0)261294560E-mail:[email protected]
JAPANCooperCrouse-HindsJapanKK,MTBuilding3F2-7-5ShibaDaimon,Minato-ku,Tokyo,Japan105-0012
Tel:+81(0)364303128Fax:+81(0)364303129E-mail:[email protected]
SOUTH KOREACooperCrouse-HindsKorea12F,VisionTower707-2Yeoksam-DongGangnam-Gu,Seoul135-080,SouthKorea.
Tel:+82234846795Fax:+82234846778E-mail:[email protected]
NETHERLANDSMTLInstrumentsBVTerheijdenseweg465,4825BKBredaTheNetherlands
Tel:+31(0)767505360Fax:+31(0)767505370E-mail:[email protected]
SINGAPORECooperCrouse-HindsPteLtdNo2SerangoonNorthAvenue5,#06-01FuYuBuildingSingapore554911
Tel:+6564877887Fax:+6564877997E-mail:[email protected]
UNITED ARAB EMIRATESMTLInstruments,VillaNo.4,Sector2-17Street6,POBox53234AbuDhabi,UAE
Tel:+97124466840Fax:+97124466841E-mail:[email protected]
UNITED KINGDOMMeasurementTechnologyLimited,GreatMarlings,Butterfield,LutonBedsLU28DL
Tel:+44(0)1582723633Fax:+44(0)1582422283E-mail:[email protected]
AMERICASCooperCrouse-HindsMTLInc.3413N.SamHoustonParkwayW.Suite210,HoustonTX77086,USA
Tel:+1281-571-8065Fax:+1281-571-8069E-mail:[email protected]
CHALLENGER 22i Upgrade Kit Remote PC TerminalsFor modern Operation and Visualization on sitein hazardous areas Zone 1 / 2
AmemberoftheMTLInstrumentsgroupwww.gecma.com e-mail:[email protected]
The Remote Operator Station “Challenger”, withover 15.000 units installed in hazardous locationsworldwide, is themostsuccessfulproductof itskind.Existingcustomerscanupgradetoa22”widescreensolution that allows the user to keep the existingsupporting infrastructure in place.The upgrade kit isdesignedforuserswhoaremigratingtoanewProcessControl System that offers a higher resolution anddemandsabiggerscreentodisplaymoreinformationwithout the need to replace the existing visualizationsolutioninthefield.
Users can leave their existing installation as is andonly need to unplug the data connectors, dismountthe display housing, replace it with the new 22”display housing from the upgrade kit and reconnecttheconnectors in thehousing tobeready togo.Theupgradekitisfullybackwardcompatibletotheoriginalsystemandwillmeetthespecificationsfortemperaturerange,hazardousareaandIngressProtectionratingoftheexistingchallengersolution.The22”displayoffersaresolutionof1680x1050pixelsinapictureratioof16:10onatrue22inchscreenandisavailablewithorwithoutTouchScreenfunctionality.
Gecmaalsooffersawidevarietyofspecial,customizedhousings tailored to applications in hazardous areaswherespaceislimitedorwherevariouscontrolelementsmustbeintegratedintothevisualizationsolution.
Gecma–PioneersinHMI
IntrinsicallysafeRemotePCterminalsforhazardousareasZone1/Zone2
CertifiedbyATEX,IECEx
Challenger 22i remote PC-Terminal
CHALLENGER22iUpgradeKit
UpgradeKit Optional
LEDDisplay•Intrinsicallysafepanel-mountmodule•IngressprotectionIP66fromfront/NEMA4x•22”screendiagonal(uptoWSXGA)•Capableofdisplayingmorethan16millioncolors•ProtectionclassII2GEExibIICT4•ATEX/IECEx
FlexibleModularDesign
OPTIOnal TOUCh SCreenDisplay•TouchScreenasfoilorglassversion•Resistivetouchtechnology•5-wiretechnology•Canbeoperatedwithgloves,penandfingers•Connection:RS232serialinterface•ProtectionclassII2GEExibIICT4•ATEX/IECEx
Keyboard•Intrinsicallysafepanel-mountmodule•IngressprotectionIP66/NEMA4Xfromfront•Foilprotectedshortstrokekeyboard•105keys,IBM*compatible•Standardlayouts:German,English,French•Morethan30languagesonrequest•Speciallayoutsonrequest•Polyesterfoilprintedfrombehind-resistantagainst manysolvents•ProtectionclassExII2GExibIICT4ProtectionclassDUST:ExII2DExtDA21IP6XT120°C•ATEX/UL/C-UL/TIIS/IECEx/NEPSI...
Mouse•Intrinsicallysafepanel-mountmodule•IngressprotectionIP66fromfront/NEMA4X•4-steppressure-sensitivemouseguidance•2pushbuttons•ProtectionclassII2GEExibIICT4•ATEX/UL/C-UL/TIIS/IECEx/NEPSI...
Trackball•Intrinsicallysafepanel-mountmodule•IngressprotectionIP65fromfront•55mmball•2pushbuttons•ProtectionclassII2GEExibIICT4•ATEX/UL/C-UL/TIIS/IECEx/NEPSI...
TouchPad•Intrinsicallysafepanel-mountmodule•IngressprotectionIP66fromfront/NEMA4X•Specialresistivefoil•High-definitionresolution-upto200dpi•2pushbuttons•Canbeoperatedwithgloves,penandfingers•ProtectionclassGAS:II2GEExiaIICT4ProtectionclassDUST:ExII3DT60°CIP6X•ATEX/TIIS/IECEx/NEPSI...
Joystick•Intrinsicallysafepanel-mountmodule•IngressprotectionIP66fromfront/NEMA4X•High-precisionmouseguidance•Wearlessupto15millionactuations•Extremelylow-maintenance•2pushbuttons,optionally3pushbuttons•Button-in-joystickfunctionoptionally•ProtectionclassGAS:II2GEExiaIICT4•ATEX/TIIS/IECEx/NEPSI...
CardReader •Intrinsicallysafepanel-mountmodule•IngressprotectionIP66fromfront/NEMA4X•Non-contactidentification•Mifareprotocolasstandard(othersonrequest)•SuitableforthemajorityofcompanyID‘s•Connection:RS232serialinterface•ProtectionclassII2GEExibIICT4•ATEX/UL/C-UL/TIIS/IECEx/NEPSI...
OptionsandAccessories
SPeCIal enClOSUreS
Enclosures
Interfaces
FhP STanDarD enClOSUre
Key switch sW1•KeySwitchforlockingthe Keyboard/Mouse/Trackball ontheCHALLENGER•Integratedinthe CHALLENGERenclosure•IngressprotectionIP67from front/NEMA4X
Key switch sW2•KeyswitchintegratedintotheRack 42/Rack84•TolockKeyboard/Mouse/Trackball ontheCHALLENGERortolockthe controlroomoperation
emergency stop Button•EmergencyStopButtontoturnoff individualconnections (localconnection)•IngressprotectionIP65fromfront•ProtectionclassII2GEExdeIICT6
rs 232 Interface•Fullyduplex-capable RS232Interface•Intrinsicallysafemodelorindustry modelincludingseparatedatacable fortheconnectionofallRS232-compatibleequipment•Protectionclass:Transmissionunit:II2GEExibIICT4Receivingunit:II(2)G[EExib]IIC•ATEX,UL,C-UL,TIIS...certified
VHH VH DH DTH
SH 1 SH 2 SH 3 SH 4
SH 5 SH 6 SH 7 SH 8
SH 9 SH 10 SH 12 SH 15
•Hygienic,ergonomicFieldDeskEnclosuretohousetheDisplay, Keyboard,MouseorTrackball,CardReader•Keyboardinclinedby30°•ProtectionsystemIP66/NEMA4X•StainlessSteel1.4301(1.4404/316Lopt.)•Polishedto240granulation
Floor mounting
Wall mounting
Ceiling mounting
*Keyboardhousingandmountingpipeareoptionalandnotrequiredforupgradekit
www.gecma.com e-mail:[email protected]
The Remote Operator Station “Challenger”, withover 15.000 units installed in hazardous locationsworldwide, is themostsuccessfulproductof itskind.Existingcustomerscanupgradetoa22”widescreensolution that allows the user to keep the existingsupporting infrastructure in place.The upgrade kit isdesignedforuserswhoaremigratingtoanewProcessControl System that offers a higher resolution anddemandsabiggerscreentodisplaymoreinformationwithout the need to replace the existing visualizationsolutioninthefield.
Users can leave their existing installation as is andonly need to unplug the data connectors, dismountthe display housing, replace it with the new 22”display housing from the upgrade kit and reconnecttheconnectors in thehousing tobeready togo.Theupgradekitisfullybackwardcompatibletotheoriginalsystemandwillmeetthespecificationsfortemperaturerange,hazardousareaandIngressProtectionratingoftheexistingchallengersolution.The22”displayoffersaresolutionof1680x1050pixelsinapictureratioof16:10onatrue22inchscreenandisavailablewithorwithoutTouchScreenfunctionality.
Gecmaalsooffersawidevarietyofspecial,customizedhousings tailored to applications in hazardous areaswherespaceislimitedorwherevariouscontrolelementsmustbeintegratedintothevisualizationsolution.
Gecma–PioneersinHMI
IntrinsicallysafeRemotePCterminalsforhazardousareasZone1/Zone2
CertifiedbyATEX,IECEx
Challenger 22i remote PC-Terminal
CHALLENGER22iUpgradeKit
UpgradeKit Optional
LEDDisplay•Intrinsicallysafepanel-mountmodule•IngressprotectionIP66fromfront/NEMA4x•22”screendiagonal(uptoWSXGA)•Capableofdisplayingmorethan16millioncolors•ProtectionclassII2GEExibIICT4•ATEX/IECEx
FlexibleModularDesign
OPTIOnal TOUCh SCreenDisplay•TouchScreenasfoilorglassversion•Resistivetouchtechnology•5-wiretechnology•Canbeoperatedwithgloves,penandfingers•Connection:RS232serialinterface•ProtectionclassII2GEExibIICT4•ATEX/IECEx
Keyboard•Intrinsicallysafepanel-mountmodule•IngressprotectionIP66/NEMA4Xfromfront•Foilprotectedshortstrokekeyboard•105keys,IBM*compatible•Standardlayouts:German,English,French•Morethan30languagesonrequest•Speciallayoutsonrequest•Polyesterfoilprintedfrombehind-resistantagainst manysolvents•ProtectionclassExII2GExibIICT4ProtectionclassDUST:ExII2DExtDA21IP6XT120°C•ATEX/UL/C-UL/TIIS/IECEx/NEPSI...
Mouse•Intrinsicallysafepanel-mountmodule•IngressprotectionIP66fromfront/NEMA4X•4-steppressure-sensitivemouseguidance•2pushbuttons•ProtectionclassII2GEExibIICT4•ATEX/UL/C-UL/TIIS/IECEx/NEPSI...
Trackball•Intrinsicallysafepanel-mountmodule•IngressprotectionIP65fromfront•55mmball•2pushbuttons•ProtectionclassII2GEExibIICT4•ATEX/UL/C-UL/TIIS/IECEx/NEPSI...
TouchPad•Intrinsicallysafepanel-mountmodule•IngressprotectionIP66fromfront/NEMA4X•Specialresistivefoil•High-definitionresolution-upto200dpi•2pushbuttons•Canbeoperatedwithgloves,penandfingers•ProtectionclassGAS:II2GEExiaIICT4ProtectionclassDUST:ExII3DT60°CIP6X•ATEX/TIIS/IECEx/NEPSI...
Joystick•Intrinsicallysafepanel-mountmodule•IngressprotectionIP66fromfront/NEMA4X•High-precisionmouseguidance•Wearlessupto15millionactuations•Extremelylow-maintenance•2pushbuttons,optionally3pushbuttons•Button-in-joystickfunctionoptionally•ProtectionclassGAS:II2GEExiaIICT4•ATEX/TIIS/IECEx/NEPSI...
CardReader •Intrinsicallysafepanel-mountmodule•IngressprotectionIP66fromfront/NEMA4X•Non-contactidentification•Mifareprotocolasstandard(othersonrequest)•SuitableforthemajorityofcompanyID‘s•Connection:RS232serialinterface•ProtectionclassII2GEExibIICT4•ATEX/UL/C-UL/TIIS/IECEx/NEPSI...
OptionsandAccessories
SPeCIal enClOSUreS
Enclosures
Interfaces
FhP STanDarD enClOSUre
Key switch sW1•KeySwitchforlockingthe Keyboard/Mouse/Trackball ontheCHALLENGER•Integratedinthe CHALLENGERenclosure•IngressprotectionIP67from front/NEMA4X
Key switch sW2•KeyswitchintegratedintotheRack 42/Rack84•TolockKeyboard/Mouse/Trackball ontheCHALLENGERortolockthe controlroomoperation
emergency stop Button•EmergencyStopButtontoturnoff individualconnections (localconnection)•IngressprotectionIP65fromfront•ProtectionclassII2GEExdeIICT6
rs 232 Interface•Fullyduplex-capable RS232Interface•Intrinsicallysafemodelorindustry modelincludingseparatedatacable fortheconnectionofallRS232-compatibleequipment•Protectionclass:Transmissionunit:II2GEExibIICT4Receivingunit:II(2)G[EExib]IIC•ATEX,UL,C-UL,TIIS...certified
VHH VH DH DTH
SH 1 SH 2 SH 3 SH 4
SH 5 SH 6 SH 7 SH 8
SH 9 SH 10 SH 12 SH 15
•Hygienic,ergonomicFieldDeskEnclosuretohousetheDisplay, Keyboard,MouseorTrackball,CardReader•Keyboardinclinedby30°•ProtectionsystemIP66/NEMA4X•StainlessSteel1.4301(1.4404/316Lopt.)•Polishedto240granulation
Floor mounting
Wall mounting
Ceiling mounting
*Keyboardhousingandmountingpipeareoptionalandnotrequiredforupgradekit
www.gecma.com e-mail:[email protected]
The Remote Operator Station “Challenger”, withover 15.000 units installed in hazardous locationsworldwide, is themostsuccessfulproductof itskind.Existingcustomerscanupgradetoa22”widescreensolution that allows the user to keep the existingsupporting infrastructure in place.The upgrade kit isdesignedforuserswhoaremigratingtoanewProcessControl System that offers a higher resolution anddemandsabiggerscreentodisplaymoreinformationwithout the need to replace the existing visualizationsolutioninthefield.
Users can leave their existing installation as is andonly need to unplug the data connectors, dismountthe display housing, replace it with the new 22”display housing from the upgrade kit and reconnecttheconnectors in thehousing tobeready togo.Theupgradekitisfullybackwardcompatibletotheoriginalsystemandwillmeetthespecificationsfortemperaturerange,hazardousareaandIngressProtectionratingoftheexistingchallengersolution.The22”displayoffersaresolutionof1680x1050pixelsinapictureratioof16:10onatrue22inchscreenandisavailablewithorwithoutTouchScreenfunctionality.
Gecmaalsooffersawidevarietyofspecial,customizedhousings tailored to applications in hazardous areaswherespaceislimitedorwherevariouscontrolelementsmustbeintegratedintothevisualizationsolution.
Gecma–PioneersinHMI
IntrinsicallysafeRemotePCterminalsforhazardousareasZone1/Zone2
CertifiedbyATEX,IECEx
Challenger 22i remote PC-Terminal
CHALLENGER22iUpgradeKit
UpgradeKit Optional
LEDDisplay•Intrinsicallysafepanel-mountmodule•IngressprotectionIP66fromfront/NEMA4x•22”screendiagonal(uptoWSXGA)•Capableofdisplayingmorethan16millioncolors•ProtectionclassII2GEExibIICT4•ATEX/IECEx
FlexibleModularDesign
OPTIOnal TOUCh SCreenDisplay•TouchScreenasfoilorglassversion•Resistivetouchtechnology•5-wiretechnology•Canbeoperatedwithgloves,penandfingers•Connection:RS232serialinterface•ProtectionclassII2GEExibIICT4•ATEX/IECEx
Keyboard•Intrinsicallysafepanel-mountmodule•IngressprotectionIP66/NEMA4Xfromfront•Foilprotectedshortstrokekeyboard•105keys,IBM*compatible•Standardlayouts:German,English,French•Morethan30languagesonrequest•Speciallayoutsonrequest•Polyesterfoilprintedfrombehind-resistantagainst manysolvents•ProtectionclassExII2GExibIICT4ProtectionclassDUST:ExII2DExtDA21IP6XT120°C•ATEX/UL/C-UL/TIIS/IECEx/NEPSI...
Mouse•Intrinsicallysafepanel-mountmodule•IngressprotectionIP66fromfront/NEMA4X•4-steppressure-sensitivemouseguidance•2pushbuttons•ProtectionclassII2GEExibIICT4•ATEX/UL/C-UL/TIIS/IECEx/NEPSI...
Trackball•Intrinsicallysafepanel-mountmodule•IngressprotectionIP65fromfront•55mmball•2pushbuttons•ProtectionclassII2GEExibIICT4•ATEX/UL/C-UL/TIIS/IECEx/NEPSI...
TouchPad•Intrinsicallysafepanel-mountmodule•IngressprotectionIP66fromfront/NEMA4X•Specialresistivefoil•High-definitionresolution-upto200dpi•2pushbuttons•Canbeoperatedwithgloves,penandfingers•ProtectionclassGAS:II2GEExiaIICT4ProtectionclassDUST:ExII3DT60°CIP6X•ATEX/TIIS/IECEx/NEPSI...
Joystick•Intrinsicallysafepanel-mountmodule•IngressprotectionIP66fromfront/NEMA4X•High-precisionmouseguidance•Wearlessupto15millionactuations•Extremelylow-maintenance•2pushbuttons,optionally3pushbuttons•Button-in-joystickfunctionoptionally•ProtectionclassGAS:II2GEExiaIICT4•ATEX/TIIS/IECEx/NEPSI...
CardReader •Intrinsicallysafepanel-mountmodule•IngressprotectionIP66fromfront/NEMA4X•Non-contactidentification•Mifareprotocolasstandard(othersonrequest)•SuitableforthemajorityofcompanyID‘s•Connection:RS232serialinterface•ProtectionclassII2GEExibIICT4•ATEX/UL/C-UL/TIIS/IECEx/NEPSI...
OptionsandAccessories
SPeCIal enClOSUreS
Enclosures
Interfaces
FhP STanDarD enClOSUre
Key switch sW1•KeySwitchforlockingthe Keyboard/Mouse/Trackball ontheCHALLENGER•Integratedinthe CHALLENGERenclosure•IngressprotectionIP67from front/NEMA4X
Key switch sW2•KeyswitchintegratedintotheRack 42/Rack84•TolockKeyboard/Mouse/Trackball ontheCHALLENGERortolockthe controlroomoperation
emergency stop Button•EmergencyStopButtontoturnoff individualconnections (localconnection)•IngressprotectionIP65fromfront•ProtectionclassII2GEExdeIICT6
rs 232 Interface•Fullyduplex-capable RS232Interface•Intrinsicallysafemodelorindustry modelincludingseparatedatacable fortheconnectionofallRS232-compatibleequipment•Protectionclass:Transmissionunit:II2GEExibIICT4Receivingunit:II(2)G[EExib]IIC•ATEX,UL,C-UL,TIIS...certified
VHH VH DH DTH
SH 1 SH 2 SH 3 SH 4
SH 5 SH 6 SH 7 SH 8
SH 9 SH 10 SH 12 SH 15
•Hygienic,ergonomicFieldDeskEnclosuretohousetheDisplay, Keyboard,MouseorTrackball,CardReader•Keyboardinclinedby30°•ProtectionsystemIP66/NEMA4X•StainlessSteel1.4301(1.4404/316Lopt.)•Polishedto240granulation
Floor mounting
Wall mounting
Ceiling mounting
*Keyboardhousingandmountingpipeareoptionalandnotrequiredforupgradekit
www.gecma.com e-mail:[email protected]
Challenger 22i remote PC-Terminal
aPPlICaTIOnS
PharMaCeUTICal
InDUSTrY
CheMICal
InDUSTrY
OIl & gaS aUTOMOBIle
PrODUCTIOn
WaSTe WaTer
TreaTMenT PlanT
COal FIreD
POWer PlanT
InCIneraTIOn
PlanT
OTher
PrOCeSSeS
CerTIFICaTeS
aTex IeCex
tested by:
• Intrinsicallysafecertifiedcomponentsforoperationandvisualization
• Modularconfiguration
• Trouble-freePChardwarechangesandsoftwareupdates
• AmbientTemperature-10°Cto+50°C
• Lowinstallationcosts
• Excellentpicturequality
• Savingsofsoftwarecostsbycascadingupto4CHALLENGERterminalstoonePC
• Upgradekitalsoavailableforindustrialversion
BeneFITS
SaleS OFFICeS
geCMa SerVICeAllproductinformation/technicaldatasheets/drawingsandaconfigurationtooltooptimizeyourhuman-machineinterfacecanbefoundat:www.GECMA.com
www.gecma.com e-mail:[email protected]
Headquarters GeCMa Components GmbH, Heisenbergstrasse 26-40, d-50169 Kerpen, Gemany. tel: +49 2237 6996-0 Fax: +49 2237 6996-99
Configurator Products
News SupportTechnicaldrawings
Callsreturnedwithin24hours
Offersmadewithin48hours
Fastdeliverytime
ConfigureyourTerminal at www.GECMA.com
Technicalchangesreserved.EffectivefromFebruary2012
ZL-B-CHA
L22iKIT-EN-0212
AUSTRALIAMTLInstrumentsPty,CooperElectrical,205-209WoodparkRoad,POBox2577,Smithfield,NSW2164,Australia
Tel:+611300308374Fax:+611300308463E-mail:[email protected]
CHINACooperElectric(Shanghai)Co.Ltd.Room2001,ChinaLifeTower,16ChaoYangMenWaiStreet,ChaoYangDistrict,Beijing,China100020
Tel:+861059800288Fax:+861085625725E-mail:[email protected]
FRANCEMTLInstrumentssarl,LesCarrésduParc10ruedesRosiéristes,69410ChampagneauMontd’OrFrance
Tel:+33(0)478649832Fax:+33(0)478357941E-mail:[email protected]
GERMANYMTLInstrumentsGmbH,AnderGümpgesbrücke17D-41564Kaarst,Germany
Tel:+49(0)2131718930Fax:+49(0)21317189333E-mail:[email protected]
INDIAMTLIndia,No.36,NehruStreetOffOldMahabalipuramRoadSholinganallur,Chennai-600119,India
Tel:+91(0)4424501660/24501857Fax:+91(0)4424501463E-mail:[email protected]
ITALYMTLItaliasrl,ViaCantù11I-20092CiniselloBalsamoMI,Italy
Tel:+39(0)261802011Fax:+39(0)261294560E-mail:[email protected]
JAPANCooperCrouse-HindsJapanKK,MTBuilding3F2-7-5ShibaDaimon,Minato-ku,Tokyo,Japan105-0012
Tel:+81(0)364303128Fax:+81(0)364303129E-mail:[email protected]
SOUTH KOREACooperCrouse-HindsKorea12F,VisionTower707-2Yeoksam-DongGangnam-Gu,Seoul135-080,SouthKorea.
Tel:+82234846795Fax:+82234846778E-mail:[email protected]
NETHERLANDSMTLInstrumentsBVTerheijdenseweg465,4825BKBredaTheNetherlands
Tel:+31(0)767505360Fax:+31(0)767505370E-mail:[email protected]
SINGAPORECooperCrouse-HindsPteLtdNo2SerangoonNorthAvenue5,#06-01FuYuBuildingSingapore554911
Tel:+6564877887Fax:+6564877997E-mail:[email protected]
UNITED ARAB EMIRATESMTLInstruments,VillaNo.4,Sector2-17Street6,POBox53234AbuDhabi,UAE
Tel:+97124466840Fax:+97124466841E-mail:[email protected]
UNITED KINGDOMMeasurementTechnologyLimited,GreatMarlings,Butterfield,LutonBedsLU28DL
Tel:+44(0)1582723633Fax:+44(0)1582422283E-mail:[email protected]
AMERICASCooperCrouse-HindsMTLInc.3413N.SamHoustonParkwayW.Suite210,HoustonTX77086,USA
Tel:+1281-571-8065Fax:+1281-571-8069E-mail:[email protected]
CHALLENGER 22i Upgrade Kit Remote PC TerminalsFor modern Operation and Visualization on sitein hazardous areas Zone 1 / 2
AmemberoftheMTLInstrumentsgroupwww.gecma.com e-mail:[email protected]
Challenger 22i remote PC-Terminal
aPPlICaTIOnS
PharMaCeUTICal
InDUSTrY
CheMICal
InDUSTrY
OIl & gaS aUTOMOBIle
PrODUCTIOn
WaSTe WaTer
TreaTMenT PlanT
COal FIreD
POWer PlanT
InCIneraTIOn
PlanT
OTher
PrOCeSSeS
CerTIFICaTeS
aTex IeCex
tested by:
• Intrinsicallysafecertifiedcomponentsforoperationandvisualization
• Modularconfiguration
• Trouble-freePChardwarechangesandsoftwareupdates
• AmbientTemperature-10°Cto+50°C
• Lowinstallationcosts
• Excellentpicturequality
• Savingsofsoftwarecostsbycascadingupto4CHALLENGERterminalstoonePC
• Upgradekitalsoavailableforindustrialversion
BeneFITS
SaleS OFFICeS
geCMa SerVICeAllproductinformation/technicaldatasheets/drawingsandaconfigurationtooltooptimizeyourhuman-machineinterfacecanbefoundat:www.GECMA.com
www.gecma.com e-mail:[email protected]
Headquarters GeCMa Components GmbH, Heisenbergstrasse 26-40, d-50169 Kerpen, Gemany. tel: +49 2237 6996-0 Fax: +49 2237 6996-99
Configurator Products
News SupportTechnicaldrawings
Callsreturnedwithin24hours
Offersmadewithin48hours
Fastdeliverytime
ConfigureyourTerminal at www.GECMA.com
Technicalchangesreserved.EffectivefromFebruary2012
ZL-B-CHA
L22iKIT-EN-0212
AUSTRALIAMTLInstrumentsPty,CooperElectrical,205-209WoodparkRoad,POBox2577,Smithfield,NSW2164,Australia
Tel:+611300308374Fax:+611300308463E-mail:[email protected]
CHINACooperElectric(Shanghai)Co.Ltd.Room2001,ChinaLifeTower,16ChaoYangMenWaiStreet,ChaoYangDistrict,Beijing,China100020
Tel:+861059800288Fax:+861085625725E-mail:[email protected]
FRANCEMTLInstrumentssarl,LesCarrésduParc10ruedesRosiéristes,69410ChampagneauMontd’OrFrance
Tel:+33(0)478649832Fax:+33(0)478357941E-mail:[email protected]
GERMANYMTLInstrumentsGmbH,AnderGümpgesbrücke17D-41564Kaarst,Germany
Tel:+49(0)2131718930Fax:+49(0)21317189333E-mail:[email protected]
INDIAMTLIndia,No.36,NehruStreetOffOldMahabalipuramRoadSholinganallur,Chennai-600119,India
Tel:+91(0)4424501660/24501857Fax:+91(0)4424501463E-mail:[email protected]
ITALYMTLItaliasrl,ViaCantù11I-20092CiniselloBalsamoMI,Italy
Tel:+39(0)261802011Fax:+39(0)261294560E-mail:[email protected]
JAPANCooperCrouse-HindsJapanKK,MTBuilding3F2-7-5ShibaDaimon,Minato-ku,Tokyo,Japan105-0012
Tel:+81(0)364303128Fax:+81(0)364303129E-mail:[email protected]
SOUTH KOREACooperCrouse-HindsKorea12F,VisionTower707-2Yeoksam-DongGangnam-Gu,Seoul135-080,SouthKorea.
Tel:+82234846795Fax:+82234846778E-mail:[email protected]
NETHERLANDSMTLInstrumentsBVTerheijdenseweg465,4825BKBredaTheNetherlands
Tel:+31(0)767505360Fax:+31(0)767505370E-mail:[email protected]
SINGAPORECooperCrouse-HindsPteLtdNo2SerangoonNorthAvenue5,#06-01FuYuBuildingSingapore554911
Tel:+6564877887Fax:+6564877997E-mail:[email protected]
UNITED ARAB EMIRATESMTLInstruments,VillaNo.4,Sector2-17Street6,POBox53234AbuDhabi,UAE
Tel:+97124466840Fax:+97124466841E-mail:[email protected]
UNITED KINGDOMMeasurementTechnologyLimited,GreatMarlings,Butterfield,LutonBedsLU28DL
Tel:+44(0)1582723633Fax:+44(0)1582422283E-mail:[email protected]
AMERICASCooperCrouse-HindsMTLInc.3413N.SamHoustonParkwayW.Suite210,HoustonTX77086,USA
Tel:+1281-571-8065Fax:+1281-571-8069E-mail:[email protected]
CHALLENGER 22i Upgrade Kit Remote PC TerminalsFor modern Operation and Visualization on sitein hazardous areas Zone 1 / 2
AmemberoftheMTLInstrumentsgroupwww.gecma.com e-mail:[email protected]