Upload
others
View
10
Download
0
Embed Size (px)
Citation preview
440 441
cex-EP1cex-EP1
A B C
B
C
C
B
A
A
A
ABC
N L
N L Earth
N LN L
N
230 VA
Scenario Switch
Power Line Carriertechnology
To be used in new or renovated traditional installation (L+N required) up to 300 m2
PLC technology, which systematically includes neutral, is a control solution for managing functions such as lighting, roller blinds and heating. It can be used to control functions
individually or by creating scenarios, or even remotely (via the Internet) using the IP Axiophone. All the functions can be combined with safety and communication solutions.
CélianeSee p. 528-538
Galea LifeSee p. 648-671
SynergySee p. 590-591
MalliaSee p. 630-631
RANGES INCORPORATING PLC TECHNOLOGY
MOBILE SCENARIO CONTROL
MOBILE SCENARIO SWITCH(See p. 442) Can control up to 6 scenarios from any chosen location
REMOTE CONTROL SCENARIO CONTROLLER (See p. 442) Controls the whole electrical installation.Up to 4 scenarios plus TV
MEDIA SERVER(See p. 445) Controls : 10 scenarios, broadcasting Hi-Fi channels, home cinema, etc...
REMOTE CONTROL
IP AXIOPHONE(See p. 445) Controls the electrical functions of the home remotely via the Internet
AUTOMATIC SWITCH (See p. 442) Controls and times the lighting each time someone passes
LOCAL CONTROL
MOBILE DIMMER SWITCHED SOCKET(See p. 529)Controls the lighting from the socket
CENTRALIZED ROLLER BLINDS CONTROL(See p. 444) Controls all the blinds in one single action
GENERAL CONTROL
WIRING DIAGRAM
Indicates lighting controlIndicates lighting control via socketsIndicates roller blinds control
AB
C
SIMPLE TO INSTALL FOR MAXIMUM COMFORT
Motor
SCENARIO CONTROLLER WITH TOUCH SCREEN(See p. 535) Manual or automatic scenario control
PLC transmitterIR receiver switch
PLC transmitter/receiver switch
IR mobile scenario controller
www.klinkmann.com
www.klinkmann.com
440 441
cex-EP1cex-EP1
A B C
B
C
C
B
A
A
A
ABC
N L
N L Earth
N LN L
N
230 VA
Scenario Switch
Power Line Carriertechnology
To be used in new or renovated traditional installation (L+N required) up to 300 m2
PLC technology, which systematically includes neutral, is a control solution for managing functions such as lighting, roller blinds and heating. It can be used to control functions
individually or by creating scenarios, or even remotely (via the Internet) using the IP Axiophone. All the functions can be combined with safety and communication solutions.
CélianeSee p. 528-538
Galea LifeSee p. 648-671
SynergySee p. 590-591
MalliaSee p. 630-631
RANGES INCORPORATING PLC TECHNOLOGY
MOBILE SCENARIO CONTROL
MOBILE SCENARIO SWITCH(See p. 442) Can control up to 6 scenarios from any chosen location
REMOTE CONTROL SCENARIO CONTROLLER (See p. 442) Controls the whole electrical installation.Up to 4 scenarios plus TV
MEDIA SERVER(See p. 445) Controls : 10 scenarios, broadcasting Hi-Fi channels, home cinema, etc...
REMOTE CONTROL
IP AXIOPHONE(See p. 445) Controls the electrical functions of the home remotely via the Internet
AUTOMATIC SWITCH (See p. 442) Controls and times the lighting each time someone passes
LOCAL CONTROL
MOBILE DIMMER SWITCHED SOCKET(See p. 529)Controls the lighting from the socket
CENTRALIZED ROLLER BLINDS CONTROL(See p. 444) Controls all the blinds in one single action
GENERAL CONTROL
WIRING DIAGRAM
Indicates lighting controlIndicates lighting control via socketsIndicates roller blinds control
AB
C
SIMPLE TO INSTALL FOR MAXIMUM COMFORT
Motor
SCENARIO CONTROLLER WITH TOUCH SCREEN(See p. 535) Manual or automatic scenario control
PLC transmitterIR receiver switch
PLC transmitter/receiver switch
IR mobile scenario controller
www.klinkmann.com
442
cex-EP3
PLC lighting control power line carrier technology with CélianeTM range
Cover plates, plates and supports selection chart (p. 549 to 565)
Particularly suitable for new buildings and heavy renovationCan be installed in living areas, reception areas, working areas (stores, restaurants, medical centres...)Can be controlled by IR from the same room or by PLC with lighting scenarios controller or other scenario controllers (p. 534, 535)110-230 VA - 50/60Hz
672 09 (Wenge Coloured)
NEW
672 15 (Oxidised Iron)
Red catalogue numbers: New products
Pack Cat.Nos Dimmer switches
Switch for on/off/dimming control of the circuit connected to the terminals With 2 factory-set lighting levels accessed using the + and - buttons The transmitter function is used for on/off/dimming control of other light switches in the installation The receiver function is used to execute on/off/ dimming commands received from lighting scenarios controller (p. 534), on/off commands received from scenarios controllers (p. 534, 535), or any other lighting control in the installation, on its lighting circuit 3-wire installation in box depth 50 mm recommended Self-regulating against overloads
PLC transmitter/receiver and IR receiver dimmer switches with indicator Display the light level via LEDs (5 blue LEDs) Faulty load indicated by red LED 1 672 12 1 x 300 W
Multi-load Protected against short-circuits
1 672 14 1 x 600 W Resistive and inductive loads
Pack Cat.Nos Switches
For the on/off control of local or remote circuits Transmitter function: for the remote on/off control of other light switches in the installation Receiver function: to execute commands received (via PLC or IR) from scenario controllers (p. 534, 535), or from any other lighting control in the installation, on the lighting circuit(s). Any load 3-wire installation in box depth 50 mm recommended
PLC transmitter/receiver and IR receiver switches with indicator
Display, via the indicator light, the status of the output being controlled
1 672 03 Single switch 1 x 2500 W
Lighting environment controller PLC transmitter/receiver lighting environment
controller 1 672 09 Used to create and manage
lighting environments Its transmitter function allows it to control switches, dimmer switches and electric blind switches It can be used to create 11 scenes consisting of 13 scenarios maximum (5 with instantaneous tripping, 7 with delayed tripping and 1 "All off" scenario)
In receiver mode, the 11 scenes can be controlled by a dimmer switch, an IP Axiophone, a scenario controller with touch screen or a remote control The scenes can be either: - Static: initiated instantly - Cyclical: the scenarios run in succession at a defined regular interval - Random: the scenarios are executed randomly (simulating occupation) - Programmed: 7 day scenario programme Equipped with a LCD screen for displaying the current scene
Céliane (p. 528)
Galea life (p. 648)
Synergy (p. 590)
Mallia (p. 630)
Automatic switch
PLC transmitter/receiver automatic switch 1 672 15 1 x 1000 W - Any load
Automatic switch for control by detection of the circuit connected to the terminals Manual override possible Transmitter function: for the on/off control of other switches or controls in the installation Receiver function: to execute commands received from scenario controllers (p. 534, 535), or from any other lighting control in the installation, on its lighting circuit Adjustable light level, lighting period and detection sensitivity Infrared detection Range: 3 to 10 m Time delay: 1 s to 16 min Light level threshold: 3 to 1000 lux Horizontal angle: 180° 3-wire installation in box depth 50 mm recommended
Lighting scenarios controller
PLC transmitter and IR receiver lighting scenarios controller
1 672 08 Used to switch on and off a group of switches or dimmer switches and manage 2 lighting scenarios Ideal for increasing the number of control points 2 dedicated keys for on/off and dimming +/- functions 2-wire connection Phase and Neutral Installation in box depth 50 mm recommended
Scenario controllers
IR mobile scenario controller 1 882 01 Can control up to 6 scenarios by
infrared technology LR 03 batteries supplied
IR remote control scenario 1 882 00 Allows the IR control of:
- In One by Legrand products with IR receiver - 4 scenarios - 1 TV Automatic learning procedure LR 03 batteries supplied
882 00882 01
www.klinkmann.com
443
cex-EP3
PLC lighting control power line carrier technology with Legrand wiring accessories ranges
Centralise your lighting
1 PLC lighting scenario switch to control2 dimmers with a single action
2
2 dimmers with 2 lighting points in 1 room1
211
N
N LN LN L
N
N
+ - Control a number of lighting points with a single action - Simplified wiring : no more need for wiring between appliances - Possibility to add mobile scenario controllers
Increase the number of lighting points in a corridor with automatic switches
N
N
N L
NL
N L
+ - Increase the number of lighting points in a corridor (no limit of lighting points number) - Simplified wiring : no more need for wiring between appliances
Control your lighting without moving
1 PLC mobile scenario switch to control 1 switch without moving2
1 PLC switch in a room with one lighting point1
2
1
N
882 01 N L
+ - Possibility to control a switch via a remote control - No more need to wire up an additional switch in order to have another control point
Light up a display window according to the day and timeProgramme the time settings for a lighting environment The lighting loads are connected to remote control dimmers Cat.No 036 10 in the consumer unit
1 PLC dimmers 2
Range 300 W multi load 600 W (inductive/resistive load)
PLC lighting scenarios controllers
Céliane 672 12 672 14 672 08
Galea Life 7756 49 7756 38 7756 39
Synergy- White 7358 16 7358 17 7358 18- Dark grey 7359 16 7359 17 7359 18
Mallia- White 2818 03 2818 04 2818 06
- Metal 2818 33 2818 34 2818 36
Range PLC automatic switch
Céliane 672 15
Galea Life 7756 21
Synergy- White 7358 14- Dark grey 7359 14
Mallia- White 2818 05
- Metal 2818 35
Range 1 PLC switch with indicator 2 PLC mobile scenarios controllers
Céliane 672 03
882 01882 00 (optional control of a TV set)
Galea Life 7756 35
Synergy- White 7358 11- Dark grey 7359 11
Mallia- White 2818 01
- Metal 2818 31
Range PLC lighting environment controller
Céliane 672 09
Galea Life 7756 41
www.klinkmann.com
cex-EP3
444Red catalogue numbers: New products
PLC roller blinds control power line carrier technology with CélianeTM range
PLC roller blinds control power line carrier technology with Legrand wiring accessories ranges
Centralise roller blinds control
Wind/sun safety kit compressing:- Wind/sun sensor located on the eaves, on the same side of the house as the awning- Control module located in the consumer unit : receives the sensor commands and sends them to the individual awning switchReceiver individual awning switch: controls awning raising/lowering. Can be installed as a replacement for an existing control using the same wiring :- possibility of increasing the number of individual switches- it is possible to control the awning manually, unless the wind exceeds the preset safety threshold
1
1
2 3
N L
N L
N L
+ - Control all individual switches can be centralised, reducing the amount of wiring- Possibility to add mobile scenario controllers
Automatic opening of the blinds according to the sun and wind
Install in the heart of the home, a PLC centralised roller blinds switch, flush-mounted and connected on the 230 VA
2
Individual PLC roller blinds switch installed close to the blind to be controlled, flush-mounted, connected on the 230 VA and to the terminals of the blind motor
1
Using the remote control, launch scenarios3
1 2Range PLC individual roller blinds switch PLC centralised roller blinds switch
Céliane 672 51 672 53
Galea Life - 7756 26
Synergy- White 7358 21 7358 22- Dark grey 7359 21 7359 22
Mallia- White 2818 08 2818 09
- Metal 2818 38 2818 39
Range Wind/sun safety kit PLC individual roller blinds switch
Céliane
036 03
672 51
Synergy- White 7358 21- Dark grey 7358 21
Mallia- White 2818 08
- Metal 2818 38
672 51 (Titanium) 672 53 (Nickel Velvet)
Cover plates, plates and supports selection chart (p. 549 to 565)
Particularly suitable for new buildings and heavy renovationCan be installed in living areas, reception areas, working areas (stores,restaurants, medical centres...)Can be controlled by IR from the same room or by PLC with lighting scenarios controller or scenarios controllers (p. 534, 535)
Pack Cat.Nos Roller blinds switches
PLC transmitter/receiver and IR receiver individual blind switches
Control all types of 230 V± electric blind motors to lower/raise/stop blinds with end stops Slat orientation function by long press Transmitter function: to control other individual blind switches in the installation Receiver function: to execute, on the motor connected to the terminals of the switch, commands received from: scenario controllers (p. 534, 535), individual or centralised electric blind switches Installation in box depth 50 mm recommended Max. loads at 230 V±: 1 x 500 VA Incompatible with Budendorff motors
1 672 51 Individual switch
PLC transmitter and IR receiver centralised blind switches
Transmitter switch for centralised control of a set of individual switches for electronic blinds Installation with phase and neutral in box depth 50 mm recommended
1 672 53 Used to control one group of individual switches for electrical blinds
Has two auxiliary inputs that can receive commands via potential-free contacts from conventional products (time switch, light-sensitive, switch etc.) to automate control. Indication of activation via blue LED
Wind/sun safety kit
1 036 03 Controls awnings or blinds automatically in the event of a too strong wind or excessive brightness - The sensor is installed without wiring and without batteries outside in a place exposed to the wind and sun Adjustment of wind safety (between 7 and 80 km/h) and luminosity/brightness threshold; sending of measurements by radio to the control module Recharged independently by solar energy - The control module is installed in the electrical consumer unit, connected on phase and neutral The transmitter function allows it to send raise/lower commands by PLC or Radio to the individual switch controlling the awning or blind
Céliane (p. 532)
Galea life (p. 654)
Synergy (p. 591)
Mallia (p. 631)
These products are part of Power Line Carrier technology system > See p. 440-441
www.klinkmann.com
cex-EP3
445
PLC heating control power line carrier technology with CélianeTM range
PLC heating control power line carrier technology with Legrand wiring accessories ranges
Control your heating locally or remotely
24
3
1
036 00
N
N
LN L N L
L
036 18 Remotecontrol
Install a PLC room thermostatIt transmitts on/off commands to the multifunction switch according to the desired temperature
Install an IP Axiophone It receives commands via the internet from a computer or mobile phone
An optional scenario switch can be added:- leaving scenario: reference temperature - 4 °C- scenario can be modified remotely (2 hours before returning: reference temperature)
2
3
4
Connect the underfloor heating circuit to a PLC multifunction receiver switch
1
Install a PLC programmable thermostat It transmits on/off commands to the multifunction switch according to the desired temperature to the nearest degree, on the days and at the time programmed
2
Connect the oil or gas boiler control unit contact to a PLC receiver modular multifunction switch
1
Keep the house at the right temperature at the right time with an oil or gas boiler
21
N L
036 00
N L
1 2 3 4
Range PLC multifunction switch
PLC thermostat IP axiophone PLC scenario
switch
Céliane
036 00
674 40
036 18
672 80
Galea Life 7710 94 7756 63(white cover plate)
1 2Range PLC multifunction switch PLC programmable thermostat
Céliane 036 00
672 42
Galea Life 7756 51
Cover plates, plates and supports selection chart (p. 549 to 565)
674 42 (Titanium)
Particularly suitable for new buildings and heavy renovationCan be installed in living areas, reception areas, working areas (stores,restaurants, medical centres...)
Pack Cat.Nos Thermostats
For oil or gas boilers, radiant ceiling panels, direct underfloor heating
Room thermostat 1 674 40 Adjustment range 7 to 30 °C
Adjustment accuracy ± 0.5 °C Direct connection of 8 A contact for new building work or combined with the PLC receiver Cat.No 036 00 (p. 537) for installation near the boiler for refurbishment work
Programmable room thermostats 7 day programming
Constant display of the current programme on screen Adjustment range 7 to 30 °C Adjustment accuracy ± 0.5°C 2 adjustable temperature levels Permanent programme backup Working reserve 100 hours
1 674 42 PLC thermostat 110/230 VA Breaking capacity 8 A max. Direct connection of 8 A contact for new building work or combined with the PLC receiver Cat.No 036 00 (p. 537) for installation near the boiler for refurbishment work
Scenarios controllers
For remote control of all In One by Legrand functions: lighting, blinds, heating
PLC transmitter scenarios controller 1 672 80 Can control 4 scenarios
Indication of activation via blue LED 2-wire connection - Phase and Neutral Installation in box depth 50 mm recommended
Switched sockets
Used for on/off control of the light connected to the socket
PLC transmitter/receiver mobile switched socket 2500 W To be directly connected to an existing 2P+E socket "ON/OFF" functions of the associated load Incandescent and halogen lamps 230 VA As receiver can execute the orders received from other PLC switches or from any scenarios controller (p. 534, 535)
1 882 63 German standard
1 882 64 British standard
Céliane (p. 533)
Galea life (p. 656)
672 80 (Mandarin)
Red catalogue numbers: New products
www.klinkmann.com
cex-EP3
446
PLC detectors power line carrier technology with CélianeTM range
PLC detectors power line carrier technology with Legrand wiring accessories ranges
If it detects a conducting liquid, the detector can activate a solenoid valve via multifunction switch Cat.No 036 00 which automatically closes off the water supply
If it detects a leak, the detector can activate a solenoid valve via multifunction switch Cat.No 036 00 which automatically closes off the incoming gas supply (manual reset mandatory)
If tripped, your scenario controller will display the action on its screen
It can be combined with the IP axiophone Cat.No 036 18 for remote alerting
2
2
3
3
Install a water leak detector in a place at risk (kitchen, laundry room, etc…)
Install a gas detector in a place at risk (kitchen, boiler room, etc…)
1
1
Cut-off your water supply in the event of a leak and receive an alert on your scenario controller
Cut-out your gas supply in the event of a leak and receive a remote alert
2
31
2
Solenoidvalve
036 00
N
N
L
2
1
3
2
Solenoidvalve
036 00
N
N
L
036 18Remotecontrol
N L
LAN
1 2 3
Range PLC flood detector PLC multifunction switch
PLC scenarios controllers
Céliane 675 22036 00
672 84
Galea Life 7756 77 7756 19
1 PLC gas detector 2 3
Range Methane Butane Propane
PLC multifunction switch IP Axiophone
Céliane 675 23 675 24036 00 036 18
Galea Life 7756 77 7756 79
675 22 (Titanium)
Cover plates, plates and supports selection chart (p. 549 to 565)
For installation in living areas, reception areas, offices and workplaces(shop, restaurant, medical centres, etc)
Pack Cat.Nos Detectors
To limit risks and ensure the safety of people and property in a house, detectors for use in the home are essential. They can be used to control locally and/or remotely an actuator (solenoid valve) and raise an alarm in the same room or in another room Also equipped with a NC/NO relay, a buzzer and LEDs
Flood detector 1 675 22 Detects the presence of a conducting
liquid by activating the NC/NO relay and sending a scenario to activate an actuator or inform a controller of the leak Supplied with 1 sensor and a 2 m cable For mounting in a 2-gang Batibox box depth 50 mm
Town gas or methane detector 1 675 23 Detects the presence of fuel gases
such as town gas (methane) by activating the NC/NO relay and sending a scenario to activate an actuator or inform a controller about the leak Conforming to standard EN 50194 For mounting in a 2-gang Batibox box depth 50 mm
Butane/propane gas detector 1 675 24 Detects the presence of fuel gases such
as butane/propane by activating the NC/NO relay and sending a scenario to activate an actuator or inform a controller about the leak Conforming to standard EN 50194 For mounting in a 2-gang Batibox box depth 50 mm
IP axiophone
1 036 18 To be installed inside an electric switchboard (size 6 modules) Power supply: 230 VA Has to be connected to the LAN (RJ socket) Allows the control of 10 scenarios and can relay the
information of 5 events Compatible with any product of the market equipped with web browser (PC, mobile phone, PDA…) and connected to the internet (fixed internet connection or mobile version like Wi-Fi) Can directly control PLC products Allows the displaying of any messages with its "Free text" zone (on its first page)
Lexic modular interface
4 modules PLC transmitter/receiver multifunction switch 1 036 00 For installation in the electrical consumer
unit to control 1 or 2 circuits linked to its terminals in one of 4 different operating modes: pushbutton, switch, time switch, latching relay The receiver function is used to execute, on its circuits, on/off commands received from scenarios controllers (p. 534, 535) or any other lighting control in the installation The transmitter function is used for on/off control of other lighting switches in the installation Possibility of switching off the whole installation by a scenario irrespective of the operating mode selected Also has 2 auxiliary inputs for executing, on its circuits, on/off commands received by a potential-free contact
Galea life (p. 664)Red catalogue numbers: New products
www.klinkmann.com
447
cex-EP3
scenario controls for remote controls power line carrier (PLC) technology
IP axiophone installation principle
Switch
ModemADSLrouterADSL
filter
Remote access
Communication
Heatingcontrol
Rollerblinds
L NL N L N
L NN
Heating
Local PC IP Axiophone
LAN
DTI
Wap - Telephone Remote PC
Local installation
INTERNET
Lighting
In One By Legrand
NL
IP axiophone operating principle
Secure login screen which allows local or remote internet access to control installation
Screen for remote control of different scenarios (lighting, blinds, heating, etc…) with message confirming the scenario launched
Screen for viewing different events so/as to be alerted in the event of an intruder, technical detection, etc… in a house
2
3
Customisation of scenarios Possibility of controlling and saving up to 10 scenarios
1
Media Server
Example of use of the Media Server
Create the communication network for the house
Install RJ 45 sockets: one per computer, one close to the TV
Install the Media Server software on each of the networks computer (CD supplied)
Connect the Media Server and use the remote control supplied to select, to listen and watch on TV videos, images, music stored on the computers
2
3
4
Install a cabinet for communication network1
Install and use the Media Server
2
2
3
3
4
4
1
882 22
These products are part of Power Line Carrier technology system > See p. 440-441