8
This certificate is the property of Warrington Certification Limited, Holmesfield Road, Warrington, Cheshire WA1 2DS, UK. Registered company No. 02250182. Signed and sealed for and on behalf of CERTIFIRE Sir Ken Knight Paul Duggan Chairman Certification Manager WCL Impartiality Committee Warrington Certification Ltd CERTIFICATE OF APPROVAL No CF 5168 This is to certify that, in accordance with TS00 General Requirements for Certification of Fire Protection Products The undermentioned products of 1 Page 1 of 8 EWAI COMPANY LIMITED Hamad Medical City CP300B Hospital Fit Out P.O.Box P3808, Doha, Qatar Tel: 974-7013-5381 Fax: 974-4437-7359 Have been assessed against the requirements of the Technical Schedule(s) denoted below and are approved for use subject to the conditions appended hereto: _____________________________________________________________________________________________________ CERTIFIED PRODUCT TECHNICAL SCHEDULE Non-Load Bearing 1 Hr and 2 Hr Fire Rated Plaster Board Shaft Wall and Drywall Partitions TS49 Vertical and Horizontal Separating Elements Issued: 29 th October 2015 Valid to: 28 th October 2020

CERTIFICATE OF APPROVAL No CF 5168€¦ · EWAI Corporation– Non-Load Bearing 1 Hr and 2 Hr Fire Rated Plaster Board Shaft Wall and Drywall Partitions Comprising Gyproc boards and

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: CERTIFICATE OF APPROVAL No CF 5168€¦ · EWAI Corporation– Non-Load Bearing 1 Hr and 2 Hr Fire Rated Plaster Board Shaft Wall and Drywall Partitions Comprising Gyproc boards and

This certificate is the property of Warrington Certification Limited, Holmesfield Road, Warrington, Cheshire WA1 2DS, UK. Registered company No. 02250182.

Signed and sealed for and on behalf of CERTIFIRE

Sir Ken Knight Paul Duggan Chairman Certification Manager

WCL Impartiality Committee Warrington Certification Ltd

CERTIFICATE OF APPROVAL No CF 5168

This is to certify that, in accordance with

TS00 General Requirements for Certification of Fire Protection Products The undermentioned products of

1

Page 1 of 8

EWAI COMPANY LIMITED

Hamad Medical City CP300B Hospital Fit Out P.O.Box P3808, Doha, Qatar

Tel: 974-7013-5381 Fax: 974-4437-7359

Have been assessed against the requirements of the Technical Schedule(s) denoted below and are approved for use subject to the conditions

appended hereto: _____________________________________________________________________________________________________

CERTIFIED PRODUCT TECHNICAL SCHEDULE

Non-Load Bearing 1 Hr and 2 Hr Fire Rated Plaster Board Shaft Wall and Drywall Partitions

TS49 Vertical and Horizontal Separating Elements

Issued: 29th October 2015

Valid to: 28th October 2020

Page 2: CERTIFICATE OF APPROVAL No CF 5168€¦ · EWAI Corporation– Non-Load Bearing 1 Hr and 2 Hr Fire Rated Plaster Board Shaft Wall and Drywall Partitions Comprising Gyproc boards and

This certificate is the property of Warrington Certification Limited, Holmesfield Road, Warrington, Cheshire WA1 2DS, UK. Registered company No. 02250182.

CERTIFICATE No CF 5168 EWAI COMPANY LIMITED

Page 2 of 8 Signed AH/008

Issued: 29th

October 2015 Valid to: 28

th October 2020

EWAI Corporation– Non-Load Bearing 1 Hr and 2 Hr Fire Rated Plaster Board Shaft Wall and Drywall Partitions Comprising Gyproc boards and Gypframe and A-Metal studs and tracks

1. This approval relates to the use of the above partitions in providing a fire resistance performance of up to 120 minutes insulation, and integrity, as defined in BS 476: Part 22: 1987.

2. As these constructions have been tested following the requirements of the ASTM E119-12a; Standard Test Methods for Fire Tests of Building Construction and Materials, they also show a Fire Resistance Rating as defined in this standard of up to 120 minutes.

3. This certification is designed to demonstrate compliance of the product or system specifically with Approved Document B (England and Wales), Section 2 of the Technical Standards (Scotland), Technical Booklet E (N. Ireland). If compliance is required to other regulatory or guidance documents there may be additional considerations or conflict to be taken into account.

4. The partitions are approved on the basis of:

i) Initial type testing ii) Audit testing at the frequency specified in TS49

iii) A design appraisal against TS49 iv) Inspection and surveillance of factory production control v) Certification of Quality Management Systems to ISO 9001:2008

5. Initial type testing was done using the ASTM E119-12a; Standard Test Methods for Fire

Tests of Building Construction and Materials. The test results were assessed by Exova

Warringtonfire against the requirements of the BS 476: Part 22: 1987.

6. Inspection and surveillance was carried out at the building site where the partitions were

constructed.

7. The non-loadbearing partition assemblies comprise Gyproc building boards fixed onto a

Gypframe or A-Metal metal framing system. 8. The partition assemblies shall be mechanically fixed to wall and floor constructions having

a fire resistance of at least the same period as the partition. 9. The approval relates to ongoing production. The product and/or its immediate packaging is

identified with the manufacturer’s name, the product name or number, the CERTIFIRE name or name and mark, together with the CERTIFIRE certificate number and application where appropriate.

This approval relates to non-loadbearing partition assemblies in terms of the integrity and insulation performance criteria of BS 476: Part 22: 1987.

Page 3: CERTIFICATE OF APPROVAL No CF 5168€¦ · EWAI Corporation– Non-Load Bearing 1 Hr and 2 Hr Fire Rated Plaster Board Shaft Wall and Drywall Partitions Comprising Gyproc boards and

This certificate is the property of Warrington Certification Limited, Holmesfield Road, Warrington, Cheshire WA1 2DS, UK. Registered company No. 02250182.

CERTIFICATE No CF 5168 EWAI COMPANY LIMITED

Page 3 of 8 Signed AH/008

Issued: 29th

October 2015 Valid to: 28

th October 2020

Plaster Board Shaft Wall/120 minutes integrity and insulation - 1 The minimum specification for the EWAI Corporation 120 minute partition system (option 1) is as follows: Facing – fire side Facing – unexposed side I-studs Perimeter tracks Fixings of panels

2 layers of Gyproc FireStop board, thickness 15 mm 1 layer of Gyproc Coreboard, thickness 19 mm

Gypframe 150SC29, 150/90 x 0.9 mm, at 600 mm centres Gypframe 150DC29, 150 x 0.9 mm, anchored at 600 mm centres 25 mm (first layer) and 42 mm (second layer) Gyproc Jack point

screws at 300 mm centres Sealant Gyproc Jointing Compound and Gyproc Paper Tape over the panel

joints Cavity insulation 24 kg/m

3 glass wool, thickness 100 mm

This shaft wall has a Fire Resistance Rating of 120 minutes as specified in the ASTM E119-12a; Standard Test Methods for Fire Tests of Building Construction and Materials Plaster Board Shaft Wall/120 minutes integrity and insulation - 2 The minimum specification for the EWAI Corporation 120 minute partition system (option 2) is as follows: Facing – fire side Facing – unexposed side I-studs Perimeter tracks Fixings of panels

1 layer of Gyproc FireStop board, thickness 15 mm (inside) 1 layer of Gyproc FireStop MR board, thickness 15 mm (outside) 1 layer of Gyproc Coreboard, thickness 19 mm

Gypframe 150SC29, 150/90 x 0.9 mm, at 600 mm centres Gypframe 150DC29, 150 x 0.9 mm, anchored at 600 mm centres 25 mm (first layer) and 42 mm (second layer) Gyproc Jack point

screws at 300 mm centres Sealant Gyproc Jointing Compound and Gyproc Paper Tape over the panel

joints Cavity insulation 24 kg/m

3 glass wool, thickness 100 mm

This shaft wall has a Fire Resistance Rating of 120 minutes as specified in the ASTM E119-12a; Standard Test Methods for Fire Tests of Building Construction and Materials

Page 4: CERTIFICATE OF APPROVAL No CF 5168€¦ · EWAI Corporation– Non-Load Bearing 1 Hr and 2 Hr Fire Rated Plaster Board Shaft Wall and Drywall Partitions Comprising Gyproc boards and

This certificate is the property of Warrington Certification Limited, Holmesfield Road, Warrington, Cheshire WA1 2DS, UK. Registered company No. 02250182.

CERTIFICATE No CF 5168 EWAI COMPANY LIMITED

Page 4 of 8 Signed AH/008

Issued: 29th

October 2015 Valid to: 28

th October 2020

Drywall system/120 minutes integrity and insulation The minimum specification for the EWAI Corporation 120 minute partition system is as follows: Facing - symmetrical C-studs Perimeter tracks Fixings of panels

2 layers of Gyproc FireStop board, thickness 15 mm A-Metal C-stud, 121.5 x 34/36 x 0.9 mm, at 600 mm centres A-Metal Extra Deep Track, 125 x 0.9 mm, nailed at 300 mm centres 25 mm (first layer) and 42 mm (second layer) Gyproc Jack point

screws at 300 mm centres Sealant Gyproc Jointing Compound and Gyproc Fiber Tape over the panel

joints

Cavity insulation 24 kg/m3 glass wool, thickness 100 mm

This drywall system has a Fire Resistance Rating of 120 minutes as specified in the ASTM E119-12a; Standard Test Methods for Fire Tests of Building Construction and Materials Drywall system/60 minutes integrity and insulation The minimum specification for the EWAI Corporation 60 minute partition system is as follows: Facing - symmetrical C-studs Perimeter tracks Fixings of panels

1 layers of Gyproc FireStop board, thickness 15 mm A-Metal C-stud, 121.5 x 34/36 x 0.9 mm, at 600 mm centres A-Metal Extra Deep Track, 125 x 0.9 mm, nailed at 300 mm centres 25 mm Gyproc Jack point screws at 300 mm centres

Sealant Gyproc Jointing Compound and Gyproc Fiber Tape over the panel joints

Cavity insulation 24 kg/m3 glass wool, thickness 100 mm

This drywall system has a Fire Resistance Rating of 60 minutes as specified in the ASTM E119-12a; Standard Test Methods for Fire Tests of Building Construction and Materials Typical detail drawings of the partitions are given below.

Page 5: CERTIFICATE OF APPROVAL No CF 5168€¦ · EWAI Corporation– Non-Load Bearing 1 Hr and 2 Hr Fire Rated Plaster Board Shaft Wall and Drywall Partitions Comprising Gyproc boards and

This certificate is the property of Warrington Certification Limited, Holmesfield Road, Warrington, Cheshire WA1 2DS, UK. Registered company No. 02250182.

CERTIFICATE No CF 5168 EWAI COMPANY LIMITED

Page 5 of 8 Signed AH/008

Issued: 29th

October 2015 Valid to: 28

th October 2020

Page 6: CERTIFICATE OF APPROVAL No CF 5168€¦ · EWAI Corporation– Non-Load Bearing 1 Hr and 2 Hr Fire Rated Plaster Board Shaft Wall and Drywall Partitions Comprising Gyproc boards and

This certificate is the property of Warrington Certification Limited, Holmesfield Road, Warrington, Cheshire WA1 2DS, UK. Registered company No. 02250182.

CERTIFICATE No CF 5168 EWAI COMPANY LIMITED

Page 6 of 8 Signed AH/008

Issued: 29th

October 2015 Valid to: 28

th October 2020

Page 7: CERTIFICATE OF APPROVAL No CF 5168€¦ · EWAI Corporation– Non-Load Bearing 1 Hr and 2 Hr Fire Rated Plaster Board Shaft Wall and Drywall Partitions Comprising Gyproc boards and

This certificate is the property of Warrington Certification Limited, Holmesfield Road, Warrington, Cheshire WA1 2DS, UK. Registered company No. 02250182.

CERTIFICATE No CF 5168 EWAI COMPANY LIMITED

Page 7 of 8 Signed AH/008

Issued: 29th

October 2015 Valid to: 28

th October 2020

Page 8: CERTIFICATE OF APPROVAL No CF 5168€¦ · EWAI Corporation– Non-Load Bearing 1 Hr and 2 Hr Fire Rated Plaster Board Shaft Wall and Drywall Partitions Comprising Gyproc boards and

This certificate is the property of Warrington Certification Limited, Holmesfield Road, Warrington, Cheshire WA1 2DS, UK. Registered company No. 02250182.

CERTIFICATE No CF 5168 EWAI COMPANY LIMITED

Page 8 of 8 Signed AH/008

Issued: 29th

October 2015 Valid to: 28

th October 2020

Further Information Further information regarding the details contained in this data sheet may be obtained from Technical Supplies and Services Co. Ltd. (Tel: + +971 4 8850474). Further information regarding CERTIFIRE certification and other approved products can be obtained from CERTIFIRE (Tel: 01925 646777, website: www.warringtonfire.net).