Upload
numan
View
12
Download
0
Embed Size (px)
DESCRIPTION
Centum vp
Citation preview
< ISD-MASP-S07011 Rev.1 >
Copyright © Yokogawa Electric Corporation<October 2008>
October 2008
Sales Promotion Group
PA PMK Dept.
Introduction
Revision 1
< ISD-MASP-S07011 Rev.1 >
Copyright © Yokogawa Electric Corporation<October 2008>
Page 2
Overview of CENTUM VPTechnical Features of HISTurbomachinery Control SolutionsMigration StorySoftware LicenseEngineering PolicyService Business PolicySchedules
Agenda
< ISD-MASP-S07011 Rev.1 >
Copyright © Yokogawa Electric Corporation<October 2008>
Page 3
< ISD-MASP-S07011 Rev.1 >
Copyright © Yokogawa Electric Corporation<October 2008>
Page 4Page 4
Overview of
< ISD-MASP-S07011 Rev.1 >
Copyright © Yokogawa Electric Corporation<October 2008>
Page 5
What is CENTUM VP?
The 8th generation of CENTUM® Series DCS.– A system with the highest reliability and the
best performance all over the world to optimize operation efficiency.
– Inheriting 30+ years of Yokogawa experience in Industrial Automation.
The core of “Production Excellence”.– Associating with the Concept.
< ISD-MASP-S07011 Rev.1 >
Copyright © Yokogawa Electric Corporation<October 2008>
Page 6
Objectives of CENTUM VP
Realize the ideal plant operations for customers.
• The well-managed and smoothly operated one, which is quiet and looks boring. (by Peter F. Drucker)
• The one to provide customers the maximum business benefit – “Operational Excellence”.
A platform to realize VigilantPlant® concept.
Visibility of InformationStable and accurate real-time information exchange throughout the plant.
Predictability of ProcessPredictive intelligence that anticipates changes and helps you plan your actions in advance.
Agility of BusinessValue chain-drive responsive operation via adaptive production management and fast intelligent decision.
< ISD-MASP-S07011 Rev.1 >
Copyright © Yokogawa Electric Corporation<October 2008>
Page 7
Asset mgt
Production mgt
Safety mgt
2005 2006 2007 2008 2009
Lifecycle Excellence
PE/LE launch•FieldMate, PRM, InsightSuiteAE•ProSafe-RS
Standard-based collaboration architecture
Real-time production execution system
VigilantPlant & SE launch
AE launch
Safety Excellence
Asset Excellence
We keep investing in the future
•PE Solution Center
•Global service
Unified & intuitive HMI•Turbine control
SE/AE evolution
Production
Excellence
Empower knowledge workers with human centric automation
2010
Life-cycle engineering environment
Operational
Productivity
Team Effectivene
ss
Human Centric
Automation
Operational Excellence
< ISD-MASP-S07011 Rev.1 >
Copyright © Yokogawa Electric Corporation<October 2008>
Page 8
Standards for Wireless
equipment
Control network
Plant data network
Office LAN
HIS &ISS Client
CAMSuite ClientVP-Quantum/FDS Client
CAMSuiteVP-Quantum/FDS
Common Field network(s)
AP APLD
Field networkgateway
VP-eXchange
Controller without I/O
Remote HIS
Business Planning
OperationalManagement
Monitoring& Control
CENTUM System Architecture (Now & Future)
I/O without Controller
< ISD-MASP-S07011 Rev.1 >
Copyright © Yokogawa Electric Corporation<October 2008>
Page 9Page 9
Technical Features of HIS
CENTUM VP R4.01
< ISD-MASP-S07011 Rev.1 >
Copyright © Yokogawa Electric Corporation<October 2008>
Page 10
New Operation & Monitoring Environment • Deliver more meaningful information to operators
• Modern, simple, and intuitive Look & Feel
• World First Windows® Vista ready DCS
Compatible with Existing CENTUM Systems• A smooth migration path is provided.
Enhanced Yokogawa & CENTUM’s Strengths• Robustness, High Performance, Scalability, Reliability,
Maintainability, Stability, Operability, etc.
Purpose of the Development (New HIS)
< ISD-MASP-S07011 Rev.1 >
Copyright © Yokogawa Electric Corporation<October 2008>
Page 11
CENTUM VP HIS/ENG
CENTUM VP HIS
FCS(Same as CENTUM
CS 3000 R3)
Control LAN (Vnet/IP or Vnet)
CENTUM VP HIS
Turbomachinery I/O Modules
New Features
– Wide-screen HIS
– New I/O Modules for Turbines and Rotating Machines
– Graphic Builder
Inherited Features (same as CENTUM CS 3000 R3)
– Basic Engineering Functions
– Components for Network & FCSs
– All the functions not specifically described here
– System capacity
Components of CENTUM VP R4.01
< ISD-MASP-S07011 Rev.1 >
Copyright © Yokogawa Electric Corporation<October 2008>
Page 12
Item For Windows VistaFor Windows XP and Windows Server 2003
CPU Core2 Duo minimum 2.13 GHzXeon dual core minimum 2.0 GHz
Core2 Duo minimum 2.13 GHzXeon dual core minimum 2.0 GHz
Main Memory
2GB or more 2 GB or more
HDD Free space of minimum 20 GB (Required)Free space of minimum 40 GB (Recommended)
Monitor SXVA (1280 x 1024) True color
WXVA, 1440 x 900, True color (for wide screen)
Graphics DirectX 9-class GPU that supports• A WDDM Driver• Pixel Shader 2.0 in hardware• 32 bits per pixel• 128MB Graphics Memory
Drive DVD-ROM
Others • Mouse, NIC• PCI/PCI-X slot for VF701 Card• Floppy Disk Drive (for Keycode)
HIS Hardware Environment
Remarks: Laptop (Notebook) PC is not supported via Vnet cards.
< ISD-MASP-S07011 Rev.1 >
Copyright © Yokogawa Electric Corporation<October 2008>
Page 13
HIS Monitors
16:10 Screen 4:3 ScreenTwo monitors(16:10 & 4:3) Four Monitors
(only 4:3)
Wide monitor is available.4-monitor is supported as standard function.– New system message window & navigation bar are
available.– The display/erase screens can be specified.– Shift and Exchange is enabled.
* 16:9 screen is also applicable.
< ISD-MASP-S07011 Rev.1 >
Copyright © Yokogawa Electric Corporation<October 2008>
Page 14
Layers of New HIS Display
Windows Desktop = Whole Area of CRT
System Message Banner = Alarm Display Area
Browser Bar = Navigation Tool
Container Window = Container Window or Pop up Window * Frame = An element of Container Window * Tab = Switches display * View = An element of Frame or Pop Up Window (R3 HIS Window)
< ISD-MASP-S07011 Rev.1 >
Copyright © Yokogawa Electric Corporation<October 2008>
Page 15
New Screen Design
The Container Window is capable of combining and displaying more than one screen.
System Message Banner compactly displays essential
information.
Arranged in the plant hierarchy, Browser
Bar allows operators to reach necessary
information instantly.
< ISD-MASP-S07011 Rev.1 >
Copyright © Yokogawa Electric Corporation<October 2008>
Page 16
System Message Banner
ALWAYS displayed on top of the screen, never overlapping with other windows.
Display Areas are “fixed”– System Alarm Button– Process Alarm Button– Operation Guide Message– Message Monitor Window– Message Display– User name – Status Icon– Time & Date– Extended Alarm Filter– Yokogawa Logo Mark
Alarm & Event Display– Latest three alarms are
always shown.
Status Icons– Engineering Functions in
Operation– Offline I/O exists– Request for Equalization– Under Virtual Testing– In Isolation
Alarm & Event Message Display Area
Status Icon Display Area
Operational Icon Display Area
Universal Color Design is applied.
< ISD-MASP-S07011 Rev.1 >
Copyright © Yokogawa Electric Corporation<October 2008>
Page 17
Browser Bar (1)
Set either left or right of the screen and retractableVariety of Tool BoxesTool Boxes can be customized(by HIS setting or by operator)
Width of the Browser Bar is also changeable.
Vertical length of each boxes are changeable by amouse operation.
< ISD-MASP-S07011 Rev.1 >
Copyright © Yokogawa Electric Corporation<October 2008>
Page 18
Browser Bar (2)
Overview/View Overview/Trend Overview/Plant
Name InputTool ButtonPreset Menu
< ISD-MASP-S07011 Rev.1 >
Copyright © Yokogawa Electric Corporation<October 2008>
Page 19
Browser Bar (3)
MinimizedBrowser Bar is now shown.
FixedBoth Browser Bar and Graphics are shown in full.Overlapping
A part of the graphic is coveredby Browser Bar.
< ISD-MASP-S07011 Rev.1 >
Copyright © Yokogawa Electric Corporation<October 2008>
Page 20
Full Screen mode– A graphic is fully
displayed on a screen
– Up to 5 Frames with Tab can be reserved.
Container Windows (Main Windows)
Tab
Window mode– Up to 5 screens
can be displayed at the same time.
< ISD-MASP-S07011 Rev.1 >
Copyright © Yokogawa Electric Corporation<October 2008>
Page 21
Frames (1) – 4 in 1
Combination of each window can be changed freely by the operators.
< ISD-MASP-S07011 Rev.1 >
Copyright © Yokogawa Electric Corporation<October 2008>
Page 22
Frames (2) – 3 in 1
Combination of each windows can be changed freely by the operators.
< ISD-MASP-S07011 Rev.1 >
Copyright © Yokogawa Electric Corporation<October 2008>
Page 23
Zoom Function
Enlarge graphics by dragging the mouse.
A small window helps you to navigate which part of the graphics are shown.
< ISD-MASP-S07011 Rev.1 >
Copyright © Yokogawa Electric Corporation<October 2008>
Page 24Page 24
Technical Features of HIS
Trend Functions
< ISD-MASP-S07011 Rev.1 >
Copyright © Yokogawa Electric Corporation<October 2008>
Page 25
Enhanced Trend Display Functions– Flexibility in Trend Overview Setting (Background & Pen Colours,
etc.)– Simultaneous Display of Data with Different Cycles– Display Multiple Index Marks– Overlapping Reference Patterns (for Batch)– Variation of Legend Display (Grid, Float, Bar)– Export Trend Graph Image as a Bitmap File– Show multiple trend views for each pen/data type instead of
plotting all the data into single trend window. (Tiling function)
Trend Acquisition Function is the same as CENTUM CS 3000 R3.– 8-pen/group (graph), 16-group/block, 50-block/HIS.
Up to 20 blocks can be acquired within its own HIS and the rest comes from other HISs.
– Up to 8 blocks for 1 sec/10 sec trend– 2880-point/pen. Can be extended by using the long-term data archive
(option)– Maximum 48 minutes of 1-sec trend can be saved.
Features of New Trend Functions
< ISD-MASP-S07011 Rev.1 >
Copyright © Yokogawa Electric Corporation<October 2008>
Page 26
Drag & Drop the pen to view on
the trend graph.
New Trend Displays
Up to 8 pens can be displayed on the same trend graph simultaneously.
< ISD-MASP-S07011 Rev.1 >
Copyright © Yokogawa Electric Corporation<October 2008>
Page 27
Background Color Variations
White
Black
Gray
Set up by “HIS Setup (.sh)”
< ISD-MASP-S07011 Rev.1 >
Copyright © Yokogawa Electric Corporation<October 2008>
Page 28
Index label(Float Display Type)
Data axis scroll bar
Time axis scroll bar
Index mark moving button
Time axis
Data
axis
Main index mark
Data axis grid
Time axis grid
Sub index mark
Trend Graph Area
< ISD-MASP-S07011 Rev.1 >
Copyright © Yokogawa Electric Corporation<October 2008>
Page 29
Variety of Trend (1) – Real Time Trend
For Continuous Process Monitoring Current Time
Plotting direction
LegendArea
Latest data is always plotted on right edge side. Index mark is movable.Data is periodically updated.
< ISD-MASP-S07011 Rev.1 >
Copyright © Yokogawa Electric Corporation<October 2008>
Page 30
Variety of Trend (2) – Batch Live Trend
Plotting direction
Current trend
Reference pattern
Current Time
Data plot starts from left edge to right edge side.
Current data are shown by overlapping the “Reference pattern”.
< ISD-MASP-S07011 Rev.1 >
Copyright © Yokogawa Electric Corporation<October 2008>
Page 31
Variety of Trend (3) – Historical Trend
Displays plotting data of the designated period or of the long term data archive.Data will not be updated.
< ISD-MASP-S07011 Rev.1 >
Copyright © Yokogawa Electric Corporation<October 2008>
Page 32
Tiling Mode (1)
Pen Based Tiling ModeAn individual graph per pen.
Discrete & Analog Tiling Mode
Discrete
Analog
< ISD-MASP-S07011 Rev.1 >
Copyright © Yokogawa Electric Corporation<October 2008>
Page 33
Tiling Mode (2) – Batch Trend
Batch Tiling Standard View
Current Data
Reference Data
Reference DataCurrent Data
Batch Tiling View (Separate Type)
< ISD-MASP-S07011 Rev.1 >
Copyright © Yokogawa Electric Corporation<October 2008>
Page 34
Legend Area
Bar
Grid
Tag name is shown in single line.When the cursor is set on the tag name, the tool tip appears and the full tag name will be displayed.
Floating
….
< ISD-MASP-S07011 Rev.1 >
Copyright © Yokogawa Electric Corporation<October 2008>
Page 35Page 35
Other Technical Features of HIS
< ISD-MASP-S07011 Rev.1 >
Copyright © Yokogawa Electric Corporation<October 2008>
Page 36
CAMS for HIS is no longer an optional function.– Included in the standard Operation and Monitoring
Function Package (Bundled).– Option code of /CAMS needed when shop order entry.
Alarm display types are selectable – CAMS or traditional type.
– Default setting is Traditional Alarm.– Setting from HIS Utility.
Alarms and Events Display
CAMS for HIS = Consolidated Alarm Management System for HIS
< ISD-MASP-S07011 Rev.1 >
Copyright © Yokogawa Electric Corporation<October 2008>
Page 37
Alarms & Events Display (CAMS)
ShelvingPane
PlantPlantHierarchyHierarchy
All Alarms
Alarms in theSelected Area
Information of Individual alarm
< ISD-MASP-S07011 Rev.1 >
Copyright © Yokogawa Electric Corporation<October 2008>
Page 38
• Customized Faceplates are regarded as “graphics”.• It can be arranged freely in the way operators want.
Customized Faceplates (Samples)
< ISD-MASP-S07011 Rev.1 >
Copyright © Yokogawa Electric Corporation<October 2008>
Page 40
Changed Windows Log-on User Rule– Any Windows users can be assigned as a HIS user.
• Only “CENTUM” Users are allowed for CENTUM CS 3000 R4.• Windows Domain Users are also allowed.
– HIS Utility is used for assigning users for HIS.
User account and the Access Privileges of HIS, ENG, Recipe, and Report are unchangedunchanged from R3.
FCS’s Access Level Function is not changed from R3.
User Account and Access Privileges
< ISD-MASP-S07011 Rev.1 >
Copyright © Yokogawa Electric Corporation<October 2008>
Page 41
“CENTUM Desktop” environment can be selected on HIS utility.– Only limited icons on the Windows desktop appear
(e.g. My computer, Trash box)– Only “Yokogawa CENTUM” can be found in the Windows
START menu.– Auto-run function of CD-ROM is disabled.– No Windows context menu with right-click on the desktop or
on the task bar– Only the Administrative User can use the command prompt– The side bar and Welcome center are not displayed.
(Windows Vista)
CENTUM Desk Top
< ISD-MASP-S07011 Rev.1 >
Copyright © Yokogawa Electric Corporation<October 2008>
Page 42
Innovation of GUI– The latest GUI Look & Feels
• Smooth Gradient– Intuitive Operation (Graphic Builder)
• VISIO like (e.g. stencil)
Flexibility– XAML Format Graphic File (eXtensible Application Markup
Language)
– Active X – Bitmap, JPEG or GIF Formats
Convertible from CENTUM CS 3000 R3 – Be careful with Active X components
Reusability– Tracing P & ID diagram, Connector, Layer, etc. to reduce
engineering cost.– Aiming reduction of development and maintenance cost.
Features of the Graphics
< ISD-MASP-S07011 Rev.1 >
Copyright © Yokogawa Electric Corporation<October 2008>
Page 43
New Graphic Builder
All the Vista colors and Vista fonts can be used for creating graphics.
< ISD-MASP-S07011 Rev.1 >
Copyright © Yokogawa Electric Corporation<October 2008>
Page 44
Stencil Area to find and pick up the parts easily.
Pan & Zoom Area to re-size quicklyto create more accurate graphic display.
Property Area and Layer Area ease to use.
NEW
NEW
NEW
Graphic Builder Function
< ISD-MASP-S07011 Rev.1 >
Copyright © Yokogawa Electric Corporation<October 2008>
Page 45
Place up to 5 Tracing Layers as the background as a graphic canvas. – No drawing on the Tracing Layer - just image files only– Layers are transparently overlapped at HIS run time.– Edit one layer at a time. – Hide layers to concentrate on one specific layer.
Graphic at HIS run time
Layer (Graphic Layer)
< ISD-MASP-S07011 Rev.1 >
Copyright © Yokogawa Electric Corporation<October 2008>
Page 46
Operation Keyboard has the same design as R3.– Single loop, 32-function key (USB)– 8-loop, 64-function key (Serial, Tokuchu)
Touch panel can be provided by the third party solution.
USB Serial
Operation Keyboard and Touch Panel
< ISD-MASP-S07011 Rev.1 >
Copyright © Yokogawa Electric Corporation<October 2008>
Page 47
Same function as CENTUM CS 3000 R3 Report package.
Exaopc package for HIS (LHS2411) and MS-Excel are needed separately.– Works on MS-Excel 2007
Report Function
< ISD-MASP-S07011 Rev.1 >
Copyright © Yokogawa Electric Corporation<October 2008>
Page 48
Same Functionality as CENTUM CS 3000 R3.– Virtual HIS, FCS simulator,
and Auto-wiring function are available.– ProSafe-RS (LHS5425) is integrated on Windows XP.
Expanded Test Function is available.– The R3 Virtual HIS cannot be started when its
engineering software revision is R4.
OTS (Operator Training Simulator) by OMEGA will be available.
Test Functions
< ISD-MASP-S07011 Rev.1 >
Copyright © Yokogawa Electric Corporation<October 2008>
Page 49
Up to 16 CENTUM VP projects can be connected.
Multi-Project Connection (1)
CENTUM VP(Upper Level)
CENTUM VP(Lower Level)
HierarchicalConnection
BidirectionalConnection
CENTUM VP
CENTUM VP
CENTUM VPProject
Upper/Lower Level
CENTUM VPProject
Upper/Lower Level
EthernetCENTUM VP
ProjectUpper/Lower Level
CENTUM VPProject
Upper/Lower Level
VnetRouterVnet/IP Vnet
CENTUM VPProject
Upper/Lower Level
CENTUM VPProject
Upper/Lower Level
Vnet or Vnet/IP
< ISD-MASP-S07011 Rev.1 >
Copyright © Yokogawa Electric Corporation<October 2008>
Page 50
Connecting with CENTUM CS 3000 R3.
Multi-Project Connection (2)
CENTUM VP(Upper Level)
CS 3000 R3(Lower Level)
HierarchicalConnection
BidirectionalConnection
CS 3000 R3
CENTUM VP
CENTUM VPProject
Upper/Lower Level
CS 3000 R3Project
Upper/Lower Level
EthernetCENTUM VP
ProjectUpper/Lower Level
CS 3000 R3Project
Upper/Lower Level
VnetRouterVnet/IP Vnet
CENTUM VPProject
Upper/Lower Level
CS 3000 R3Project
Upper/Lower Level
Vnet or Vnet/IP
* It is recommended to put CENTUM VP in the upper level for the future expandability.
< ISD-MASP-S07011 Rev.1 >
Copyright © Yokogawa Electric Corporation<October 2008>
Page 51
Connecting with CENTUM CS
Multi-Project Connection (3)
CENTUM VP(Upper Level)
CENTUM CS(Lower Level)
HierarchicalConnection
BidirectionalConnection
CENTUM CS(Lower Level)
CENTUM VP(Upper Level)
CENTUM VPProject
Upper Level
CENTUM CSProject
Lower Level
VnetRouter
Vnet/IP Vnet
CENTUM VPProject
Upper Level
CENTUM CSProject
Lower LevelVnet
CENTUM VPProject
Upper Level
CENTUM CSProject
Lower Level
Vnet VnetBCV-V
CENTUM VPProject
Upper Level CENTUM CSProject
Lower Level
Ethernet
EnetRouter/Bridge
TOKUCHU
< ISD-MASP-S07011 Rev.1 >
Copyright © Yokogawa Electric Corporation<October 2008>
Page 52Page 52
Turbomachinery Control Solutions
< ISD-MASP-S07011 Rev.1 >
Copyright © Yokogawa Electric Corporation<October 2008>
Page 53
What is Turbine Controller?
New CENTUM VP Hardware (I/O modules) with high speed responses (5 – 10 msec)
Developed mainly for Power Industry– Could be used for other industries extensively.
Catching up with Competitors– Yokogawa was the only vendor who did not
have Turbine Controller.
< ISD-MASP-S07011 Rev.1 >
Copyright © Yokogawa Electric Corporation<October 2008>
Page 54
Product Features
New I/O Modules– High Reliability of Dual I/O Modules
– High Speed Response of 5 to 10 msec
– With Unique Programmable Logics
System Features – Common Platform - CENTUM VP
– Total Control Solution from Boiler/BOP to Turbine, and Rotating Machines
– Scalable System from Small to Large Application Sizes
– Integration with CENTUM Enhanced Features such as fieldbus, PRM and others.
BOP = Balance of Plant
< ISD-MASP-S07011 Rev.1 >
Copyright © Yokogawa Electric Corporation<October 2008>
Page 55
Model Description
AGS813 Servo Module(4 LVDT inputs, 4 AIs, and 2 DIs, 2 AOs and 2 DOs; Overall Insulation)
AEGS1D Terminal Board for Servo Module
Servo Module
Terminal Board for Servo Module
Status Display
Note: These I/O modules work only when installed in a local node of a KFCS (32 MB), FFCS, or FFCS/L. » Up to 16 modules per KFCS or FFCS/L; up to 8 per
FFCS
New Hardware (1) - Servo Module
LVDT = Linear Voltage Differential Transformer
< ISD-MASP-S07011 Rev.1 >
Copyright © Yokogawa Electric Corporation<October 2008>
Page 56
Model Description
AGP813 High Speed Protection Module(6 AIs, 4 PIs, 8 DIs , and 8 DOs; Overall Insulation )
AEGP1D Terminal Board for High-Speed Protection Module
High Speed Protection Module
Status Display
Terminal Board for High-Speed Protection Module
New Hardware (2) - Protection Module
< ISD-MASP-S07011 Rev.1 >
Copyright © Yokogawa Electric Corporation<October 2008>
Page 57
I/O Modules: Regulatory Compliance
Safety Standards– CE Mark – Low Voltage Directive:
• EN61010-1 for 220-240V AC and 24V DC Power Supply
EMC Comformity Standards– CE Mark – EMC Directive:
• EN55011 Group1, Class A for 220-240V AC and 24V DC Power Supply
• EN61000-6-2 for 220-240V AC and 24V DC• EN61000-3-2 for 220-240V AC and 24V DC• EN61000-3-3 for 220-240V AC and 24V DC
< ISD-MASP-S07011 Rev.1 >
Copyright © Yokogawa Electric Corporation<October 2008>
Page 58
Model Description
LHS5800
Turbomachinery I/O Module Logic Builder Package
Logic BuilderCreates logics, via PC screen, that work in the high speed protection module and download them to the module through the FCS.
Logic Test Tool (Microsoft Excel-based tool)Works on a PC to simulate and test the logics created by Logic Builder.
New Software - Logic Builder
• LHS5800 is mandatory to use Turbomachinery I/O modules and it also needs the LHW5100 Standard Builder Function and Microsoft Excel 2003 or Excel 2007 to run.
< ISD-MASP-S07011 Rev.1 >
Copyright © Yokogawa Electric Corporation<October 2008>
Page 59
Why Turbine Control? (1)
Power is the high potential market.
x 1.6 ~ 1.7 times biggermarket than Oil & Gas(5177 mil.US$ in 2011)
Strong demands for Coal and Gas power
generation(4260 GW in 2010)
ARC 2007: DCS Worldwide Outlook Market Analysis and Forecast Through 2011 / Energy Information Adminssion/International Energy Outlook 07
< ISD-MASP-S07011 Rev.1 >
Copyright © Yokogawa Electric Corporation<October 2008>
Page 60
Why Turbine Control? (2)
ARC 2007: DCS Worldwide Outlook Market Analysis and Forecast Through 2011
DCS Market by Industry<Year 2008: Total US$16,452 Million>
US$4,034.8 M
< ISD-MASP-S07011 Rev.1 >
Copyright © Yokogawa Electric Corporation<October 2008>
Page 61
Yokogawa’s Wide Experiences in Power Market
Fossil Fuel Fired
• Coal/Oil/Gas-fired• Combined Cycle• Simple Cycle• Co-generation• Industrial Boilers• IWPPs
• Geothermal• Biomass• Waste to energy
Renewable Energy
Environmental Protection
• Flue gas desulphurization (FGD)
• Circulating fluidized bed (CFB) boilers
IWPP: Independent Water & Power Project (Plant)
But there is NO
Turbine Control!
< ISD-MASP-S07011 Rev.1 >
Copyright © Yokogawa Electric Corporation<October 2008>
Page 62
Yokogawa’s Expectation
171
61
81
99
206
338
361
587
638
0 100 200 300 400 500 600 700
Others
Metso
Honeywell
Yokogawa
Alstom
Invensys
Emerson
Siemens
ABB
By Vendors in 2003 (from 2005 ARC Report)
Total US$2,514 Mil
Increase Yokogawa share to 10% = No.4 in the World.Turbo I/O is a new tool to expand business.Show Yokogawa’s commitment to customers in the Industry.Catching up with competitors (ABB, Siemens, Emerson and Alstom)
< ISD-MASP-S07011 Rev.1 >
Copyright © Yokogawa Electric Corporation<October 2008>
Page 63
(High-Pressure/intermediate- pressure (HP/IP) stage
Turbine
Generator
Low-pressure (LP) stage
Generator
Steam inSteam out
Steam Turbine
The First Target Application
Servo ModuleControls the turbine speed by manipulating main steam control valves.
Yokogawa’s turbomachinery I/O modules were developed to meet the need for high speed (5-10 msec) control suitable for Steam Turbine Control.
High Speed Protection ModuleProtect turbine against over-speed conditions by controlling main steam stop valves.
For “gas” turlkjdfgDSine control, a thermo I/O module is required which is to be developed in the future.
(DEH Control)
< ISD-MASP-S07011 Rev.1 >
Copyright © Yokogawa Electric Corporation<October 2008>
Page 64
Outline of DEH Control (for Steam Turbines)
Servo Module
High Speed Protection Module
Steam from Boiler
Turbine Protection Turbine Master Control• Startup Control
• Shutdown Control• Speed/Load Control• Inlet/Extraction Pressure Control, etc
Main Steam CV
Main StopValve
• Over-speed Trip • Vibration Trip • Bearing Wear Trip • Low Vacuum Trip, etc.
Key controls
5ms
5-10 ms
< ISD-MASP-S07011 Rev.1 >
Copyright © Yokogawa Electric Corporation<October 2008>
Page 65
Major Functions of Steam Turbine Control
Valve Action to Trip: Fully close the main stop valve (MSV).-In general, a turbine trip induces a boiler trip (i.e., a master fuel trip [MFT])
Main Control Functions Major Protective Functions
Speed/Load controlOver-speed Trip (Primary/Secondary)
Inlet Pressure Control Vibration Trip
Start-up Control Shell Warming, CV Warming,
Speed Ratio Selection, FA/PA Transfer
Differential Expansion High Trip
Thrust Bearing Wear Trip
Generator/Line Speed Matching Control
Low Vacuum Trip
Load Limiting Lubricating Oil Pressure Low Trip
Over-speed Testing Hydraulic Oil Pressure Low Trip
Valve Testing Exhaust Temperature High Trip
Power Load Unbalance/Early Valve Actuation (Pre-trip Action)
< ISD-MASP-S07011 Rev.1 >
Copyright © Yokogawa Electric Corporation<October 2008>
Page 66
Scope of Steam Turbine Control
General Scope of Steam Turbine Control --- Boiler-Turbine Process--- Turbine Control--- Boiler Load Control--- Boiler Pressure Control--- Boiler Fuel ControlControl
Valve
Turbine Speed
Speed Sensing
Control Valve
HP LP
< ISD-MASP-S07011 Rev.1 >
Copyright © Yokogawa Electric Corporation<October 2008>
Page 67
Control Valve
Steam from MSV
High-Pressure Hydraulic Oil
Emergency Hydraulic Oil
Drain
Fast Acting Solenoid
Valve
Valve Actuator
Disk Dump Valve
Hydraulic System for Steam Control Valve
Steam to HP Turbine
Shut-off Valve
Servo Output: –50 to 50 mA to coils
Servo Module
Protection Module
DO
LVDT Input
Valve Position Control
OverspeedInterlock
Speed Input
Servo Valve
LS
LS
< ISD-MASP-S07011 Rev.1 >
Copyright © Yokogawa Electric Corporation<October 2008>
Page 68
CONTROL SYSTEMPROTECTION SYSTEM
MAGNETICPICKUP
TURBINE
LVDT
POSITIONFEEDBACK
TURBINESPEED
tc
INTERLOCK
PI
INTERLOCK
CONTROL
SPEED
CPU
TURBIINE
SERVO
CPU
PI
ENG
VALVEPOSITIONCONTROL
LOGIC
■ Field I/F LVDT 4ch, DI 2ch AO 2ch, POWER OUT 2ch■ Internal PID control period 5ms■ Capable of constructing the redundancy
Turbine Master Control
Turbine Protection
Servo Module
Hig
h S
peed
Pro
Serv
o
Hig
h S
peed
Pro
Hig
h S
peed
TC
■ Field I/F AI 6ch, PI 4ch, DI 8ch DO 8ch■ Construct the configurable logic■ Internal logic period 5ms, 10ms■ Capable of constructing the redundancy
High SpeedProtection
Module
Module Logic Test Tool
Basic System Configuration
< ISD-MASP-S07011 Rev.1 >
Copyright © Yokogawa Electric Corporation<October 2008>
Page 69
Engineering Procedure of Interlock Logic
Compressor Stall検討*0
*1SysLimChk1
AND
High_valueLow_inputInput
ResetSys
Enable
0
SysLim1
AnalogInx
Syslimit1_x
4444
4
4
1
1
1AND
Latch1
2SysLimChk
DATA
比較器 (ヒスなし)REF1 OUT1
HYS
FCN
4 Low_valueHigh_input AnalogInx 4DATA
IN_ZERO SCALING
IN_SPAN OUT1
OUT_ZERO
OUT_SPANS Q
SR Latch
R -Q
1CTL13/ 14VTF0 / 043VTF0 / 065VTF0 / 087VTF0 / 109 APC01/ 02
APC01/ 02
VTF / 1211
APB05
APB06
APB07
APA03DATA1 OUT
SEL
DATA2
SEL
VTA01VTA02 VTA03
VTA04
0
STS16
Interlock Logic
Logic test tool on Excel
CENTUM VP Builder I/O Definition
DB
2
34
Step 1 : Define logic elements to CENTUM IO builder
Step 2 : Check logic elements and save the database
1
Step 3 : Off line test on EWS PC and verify the logic.
Step 4 : Download the pre-defined logic
Logic Specifications
< ISD-MASP-S07011 Rev.1 >
Copyright © Yokogawa Electric Corporation<October 2008>
Page 70
Logics are Yokogawa’s own language.
Logic Builder: Programming Screen
< ISD-MASP-S07011 Rev.1 >
Copyright © Yokogawa Electric Corporation<October 2008>
Page 71
An Example of Total Plant Control Solutions
< ISD-MASP-S07011 Rev.1 >
Copyright © Yokogawa Electric Corporation<October 2008>
Page 72
Activities for Recognition – Evaluation Tests
Customers want “Field-proven” systems.– Virtual Test by WGTCS
• An American consulting & engineering company dedicated in Turbine Control
– On Site Test at SKODA• A Czech turbine manufacturer with no turbine
control system of their own• SKODA has difficulties to catch up with new
technologies such as fieldbus, PRM, etc.
– Field Tests in Chinese Power Plants
WGTCS: Wood Group Turbine Control Service
< ISD-MASP-S07011 Rev.1 >
Copyright © Yokogawa Electric Corporation<October 2008>
Page 73
I/O Module Evaluation Test by WGTCS (1)
Evaluation Test by Wood Group TCS (WGTCS) conducted in June 2007
Result: Successful and satisfied by WGTCS.
Servo Module
Protection Module
WGTCS Office Loveland, CO, USA
< ISD-MASP-S07011 Rev.1 >
Copyright © Yokogawa Electric Corporation<October 2008>
Page 74
I/O Modules Evaluation Tests by WGTS (2)
Overspeed interlock test
Actuator Control Test Test Simulator System
Test Items: 1) I/O response time – protection module,
servo module, and standard I/O
2) Speed input measurement with active and magnetic pickups
3) Servo valve control
4) Test using process simulator
< ISD-MASP-S07011 Rev.1 >
Copyright © Yokogawa Electric Corporation<October 2008>
Page 75
On Site Test at Skoda, Czech (1)
On Site Test at SKODA, Czech with 1 MW Steam TurbineTest Result: Successful and Well Accepted.Another On Site Test with 10MW Steam Turbine will take place in 2008to increase Yokogawa’s opportunity with SKODA.
1 MW SKODA Steam Turbine
Existing TurbineControll
er
< ISD-MASP-S07011 Rev.1 >
Copyright © Yokogawa Electric Corporation<October 2008>
Page 76
Inputs/Outputs: 83 AIs, 11 AOs, 2 PIs, 114 DIs, 64 DOs
On-site Test at SKODA, Czech (2)
AFV10D CPU nest(FCS2)
PS
U
AFV10D IO nest(FCS2)
PS
U
SB
401
SB
401
PS
UP
SU
AD
V151(0)
AFV10D CPU nest (FCS1)
PS
U
CP
451
CP
451
PS
U
AA
I143(1)
AD
V151(0)
AD
V151(0)
AD
V151(26)
AD
V551(0)
AD
V551(19)
EC
401
EC
401
CP
451
CP
451
AA
I143(0)
AA
I143(0)
AA
I143(0)
AA
I143(4)
AA
I543(8)
AG
S813
AA
I543(0)
AD
V151(25)
AD
V551(28)
AG
P813
FCS
< ISD-MASP-S07011 Rev.1 >
Copyright © Yokogawa Electric Corporation<October 2008>
Page 77
Other On-Site Tests in China
On-site evaluation test at a plant in China started in July 2008. (In progress)Approaching a turbine manufacturer who does not have its own turbine control system.Approaching Shanghai Electric (SEC) who controls their boilers by Yokogawa DCS for on-site test.Promoting to Dong Fang Electric for market penetration.
The results are not known Yet.
< ISD-MASP-S07011 Rev.1 >
Copyright © Yokogawa Electric Corporation<October 2008>
Page 78
How to Convince Customers?
Win an endorsement.
– Verification from WGTCS
Show capability in hydraulic system control
– Partnership with WGTCS.
Show performances.
– Installation Record – NuCoastal, USA (by WGTCS)
– Field Tests at SKODA (1-MW test turbine) and Others Need to establish good reputation.
< ISD-MASP-S07011 Rev.1 >
Copyright © Yokogawa Electric Corporation<October 2008>
Page 79
Where are Yokogawa Customers?
End users whose turbine control systems are in the scope of supply of I&C vendors.– e.g. China, South Africa
Customers who prefer to have both turbine control system and DCS are supplied by the same vendor.– Captive Power in the Oil & Petrochemical Plants, etc.
Turbine manufacturers who do not have their own turbine control systems and prefer to collaborate with I&C vendors. (e.g. Alstom, Skoda, etc.) – Turbine manufacturers find it difficult to catch up with the latest
technologies by their own and seek for alliances with I&C vendors.
Retrofit (Replacement of existing systems)– Where Yokogawa has delivered DCS (and other) systems and the
user is confident about Yokogawa’s capability and products.
I&C Vendor = Instrumentation and Control Vendor
< ISD-MASP-S07011 Rev.1 >
Copyright © Yokogawa Electric Corporation<October 2008>
Page 80
Applicable Markets
Power Industries– Applicable to Steam Turbine Control– YEI Power Group (Mr K. Kawabe) takes
initiatives
Other Applications (future plans)– Rotating machines and vibrating equipments
(e.g. compressors)• Need specialists & know-how of applications to
penetrate into markets
– Gas Turbine Controller• Need to develop “Temperature” Turbo I/O module.• Inevitable to obtain SIL3 Certification
These applications are still in study stage.
Need experts’ support!
< ISD-MASP-S07011 Rev.1 >
Copyright © Yokogawa Electric Corporation<October 2008>
Page 81
SIL3 Certification
Some customers require SIL3 Certification for protection modules to shut down turbines safely. This is not mandatory, however, more and more customers prefer to have SIL3 nowadays.(e.g. Europe, Middle East, Africa, Australia prefer to have SIL3. USA, Japan, Asia and China are less strict.)
Governor Control in the turbine control does not require SIL3 certification, thus Yokogawa’s turbomachinery I/O can be applied as they are. Yokogawa will apply for SIL3 certification in SIL3 certification in the futurethe future, but it is not known when to be certified.
< ISD-MASP-S07011 Rev.1 >
Copyright © Yokogawa Electric Corporation<October 2008>
Page 82Page 82
Migration & Compatibility
< ISD-MASP-S07011 Rev.1 >
Copyright © Yokogawa Electric Corporation<October 2008>
Page 83
CFFSCFFS
Migration Overview
1983 1988
19931998
2008
2001 2005
CENTUM-XLCENTUM-XL
EOPSEOPS
CFCSCFCS EFCDEFCD
ENGSENGS
PFCSPFCS
KFCSKFCSLFCS
LFCSCOPS2COPS2
CENTUM VCENTUM V
CFCS2CFCS2
COPSVCOPSV
CFCD2CFCD2
ABCABC
CENTUM CSCENTUM CS
ICSICS
EWSEWS PICSPICS
V netV net
10 MBPSDual
Redundant
Token Pass
10 MBPSDual
Redundant
Token Pass
HISHIS
CENTUM CS 3000CENTUM CS 3000
AVRAVR
FFCSFFCS
HISHIS
CENTUM CS 3000 R3CENTUM CS 3000 R3
HISHIS
FFCSFFCS
CENTUM VPCENTUM VP
1Gbps Dual
Redundant
1Gbps Dual
Redundant
Yokogawa protects your investments with long term support and multi generation compatibility
VnetI/PVnetI/P
Yokogawa assures smooth migration fromlegacy systems into the latest system to protect customers’ assets.
< ISD-MASP-S07011 Rev.1 >
Copyright © Yokogawa Electric Corporation<October 2008>
Page 84
Regard CENTUM VP as CENTUM CS 3000 R4.01 for migration.All the available FCSs, BCV, and ACG of CENTUM CS 3000 R3 are compatible with CENTUM VP.Continue to use both Vnet/IP and Vnet.“Entry Class” (=LHM packages) is available at CENTUM VP.
R2 R3 VP
LDCS CS 3000 R2 CS 3000 R3 CENTUM VP
CENTUM VP Entry Class
SDCS CS 1000 R2 CS 1000 R3CS 3000 R3 Entry Class
Overview
< ISD-MASP-S07011 Rev.1 >
Copyright © Yokogawa Electric Corporation<October 2008>
Page 85
The HIS of CENTUM VP and that of CS 3000 R3 can operate the FCSs of each other.
The ENG of CENTUM VP can handle all the CS 3000 components– HISs, FCSs, BCVs, ACGs, GSGWs, and SIOSs – ENG must be CENTUM VP for coexistence of CS 3000 and
CENTUM VP• Online maintenance of the CS3000 R3 FCS can be possible
from CENTUM VP ENG– CENTUM CS 3000 R2 needs to be upgraded to CENTUM VP.
• Two version support policy (Not tested)• Migration is possible (off-line).
Same relationship goes with ProSafe-RS – From ProSafe-RS R2.01 (Released in April 2008)
Coexistence with CENTUM CS 3000
< ISD-MASP-S07011 Rev.1 >
Copyright © Yokogawa Electric Corporation<October 2008>
Page 86
CENTUM CS 1000 Systems can be migrated into CENTUM VP Entry Class (small-scale) or CENTUM VP (large-scale).
Small-Scale System Migration (1)
Order Termination of CENTUM CS 1000 is in sight!(Scheduled in January 2009)
CENTUM VP Entry Class• Up to 8000 Tags• Connecting 256 stations • KeyCode Making Fee and Project License Fee are needed.• Enhance functions & expandability.
CENTUM VP• Up to 100,000 Tags
(Up to one million Tags by option)• Price differences between the
software licenses of CS 1000 and CENTUM VP are charged.
< ISD-MASP-S07011 Rev.1 >
Copyright © Yokogawa Electric Corporation<October 2008>
Page 87
Small-Scale System Migration (2)
CENTUM VP Entry Class is a system equivalent to CENTUM CS 1000 with enhanced functions and expandability of the system.All the CS 1000 database can be converted into CENTUM VP Entry Class automatically.Keycode making fee and Project License Fee are required for migration.
Migration
VL netVL net
CS 1000CS 1000
PFCx-S PFCx-E
V netV net
CENTUM VP Entry CENTUM VP Entry ClassClass
PFCx-S PFCx-E
AFV10x
Vnet/IP
V net Router
Note:
1. Change VF701 to VI701 on all PCs.
2. Add a Vnet router.
3. Add two (2) switching hubs, one for bus 1 and the other for bus 2.
4. Add Vnet/IP bus cables.
< ISD-MASP-S07011 Rev.1 >
Copyright © Yokogawa Electric Corporation<October 2008>
Page 88
V net
CS 1000 or CS 3000 entry
class
PFCS-S PFCS-E
CENTUM VP
V net
ooo
ABC11S-Q2
Small-Scale System Migration (3)
When system capacity increases, it is easy to change the system into redundant V net configuration.– Although AFF50S hardware specifications support only redundant V net,
AFF50S can support single V net configuration through just builder definition.
< ISD-MASP-S07011 Rev.1 >
Copyright © Yokogawa Electric Corporation<October 2008>
Page 90
Migration from Legacy Systems (Step 0)
Existing CENTUM-XLExisting CENTUM V
Existing CENTUM CS
< ISD-MASP-S07011 Rev.1 >
Copyright © Yokogawa Electric Corporation<October 2008>
Page 91
Existing CENTUM-XLExisting CENTUM V
Existing CENTUM CS
Plant Information Management System
V net or Vnet/IP
Ethernet
PIMSPlant Resource
ManagerUpper level clients
PRM
HIS
Step 1VP HIS is added to existing systems.
•The latest operation technologies
•Seamless connection
with business domains
Migration from Legacy Systems Step 1
< ISD-MASP-S07011 Rev.1 >
Copyright © Yokogawa Electric Corporation<October 2008>
Page 92
Existing CENTUM-XLExisting CENTUM V
Existing CENTUM CS
Plant Information Management System
V net orVnet/IP
Ethernet
PIMSPlant Resource
ManagerUpper level clients
PRM
HIS
VP FCSVP FCS + Existing I/O modules
Step 2 Upgrading FCS CPU to VP
•New control functions•Large capacity
Migration from Legacy Systems Step 2
< ISD-MASP-S07011 Rev.1 >
Copyright © Yokogawa Electric Corporation<October 2008>
Page 93
Existing CENTUM-XLExisting CENTUM V
Existing CENTUM CS
Plant Information Management System
V net
Ethernet
PIMSPlant Resource
ManagerUpper level clients
PRM
HIS
VP FCS
R3 FCS + Existing I/O modulesVP FCS
Step 3 (XL, V only) Upgrading I/O modules to VP
•Migration to VP is completed without changing field wiring!
Migration from Legacy Systems Step 3
< ISD-MASP-S07011 Rev.1 >
Copyright © Yokogawa Electric Corporation<October 2008>
Page 94
FCS Continuity (CENTUM V & CENTUM-XL)
(Front) (Rear)
Same connector is available.
NO CHANGE inField wiring
Field wiring
Same size CPU with large capacity
Modules are functionallycompatible and the same size with the existingI/O cards.
Old Controllers are renewed toVP without changing field wiring.
< ISD-MASP-S07011 Rev.1 >
Copyright © Yokogawa Electric Corporation<October 2008>
Page 95
CS 3000 R3 application database can be converted CENTUM VP automatically– After upgrading the system from CS 3000 to VP,
open the project on the System View then the application (project) is automatically converted to that of VP system.
Application Data Base Compatibility
< ISD-MASP-S07011 Rev.1 >
Copyright © Yokogawa Electric Corporation<October 2008>
Page 96
From CENTUM CS– Convince CENTUM CS Customers to revamp their systems.– Multi-project connection for CS system is available.– The graphic import work is done via CS 3000 R3 Graphics
(2 steps required) (this is standard function of CENTUM CS 3000)
• Except HICS special parts.– FCS application conversion can be done by tokuchu.
From CENTUM-XL, Micro-XL, CENTUM V– The HIS and the Exaopc station of R4 can work with BCVs.– Operator Station migration kit is continued.
• Bundled software is changed.– The graphic import work is done via CS 3000 R3 graphics,
using Engineering Tool.– Tag list can be converted by the engineering tool via CS
3000 R3. (ask YHQ)
Migration from Legacy Systems (1)
< ISD-MASP-S07011 Rev.1 >
Copyright © Yokogawa Electric Corporation<October 2008>
Page 98Page 98
Engineering Policy
< ISD-MASP-S07011 Rev.1 >
Copyright © Yokogawa Electric Corporation<October 2008>
Page 99
Engineering Fee & Support Organization
The engineering fee is not changed from CENTUM CS 3000 or CS 1000.– YHQ Engineering section does not change the engineering
fee.– The engineering fee of each affiliate is managed by the
engineering section of each affiliate.
The engineering tools (ETC tools) are updated.– It is going to be annouced separately,
and is delivered in a usual route.
< ISD-MASP-S07011 Rev.1 >
Copyright © Yokogawa Electric Corporation<October 2008>
Page 100Page 100
Service Business Policy
< ISD-MASP-S07011 Rev.1 >
Copyright © Yokogawa Electric Corporation<October 2008>
Page 101
New CENTUM service business policy
Based on the VigilantPlant concept, Yokogawa offers support & service to customers’ systems throughout the product lifecycle and provides customers secure and safe operations.
From Product Maintenance to Integrated System Maintenance– New service programs focus on Open System, not just
hardware.
Global Service – same level & quality worldwide– By adopting the LCMP (Lifecycle Management Program),
Yokogawa offers integrated service globally.
Fair Service based on Annual Maintenance Contract – Define the service menu clearly based on the maintenance
contract. – Differentiate the services by customers with or without
contract.
< ISD-MASP-S07011 Rev.1 >
Copyright © Yokogawa Electric Corporation<October 2008>
Page 102
LCMP (Customer value proposition)
Yokogawa listens to customer’s and respects the unique needs of customer’s plantYokogawa delivers customized lifecycle management program that best suits customer’s priorities
Delivering just what customer’s plant needs
< ISD-MASP-S07011 Rev.1 >
Copyright © Yokogawa Electric Corporation<October 2008>
Page 103
LCMP (Customer value proposition)
-Callout & Response-Onsite resident support
-Periodic maintenance-Shutdown maintenance-Diagnosis-Improvement service
-Operation training program-Advanced training program-Web training
-Parts & Spare management-Technology Refresh
-Migration Planning-EOS support
-Alarm management service-Network security consultation
-InsightsuiteAE
< ISD-MASP-S07011 Rev.1 >
Copyright © Yokogawa Electric Corporation<October 2008>
Page 104