18
FORM NO.: UC453148UK REVISION: 06/2013 CENTRIFUGAL PUMP OPERATING MANUAL UC READ AND UNDERSTAND THIS MANUAL PRIOR TO OPERATING OR SERVICING THIS PRODUCT.

CENTRIFUGAL PUMP - AxFlow

  • Upload
    others

  • View
    6

  • Download
    0

Embed Size (px)

Citation preview

Page 1: CENTRIFUGAL PUMP - AxFlow

FOR M NO.: UC453148U K R EVI S ION: 06/2013

CE NTR I FUGAL PU M P

OPE RATI NG MAN UAL

UC

R EAD AN D U N D E R STAN D TH I S MAN UAL PR IOR TO OPE RATI NG OR S E RVICI NG TH I S PROD UCT.

Page 2: CENTRIFUGAL PUMP - AxFlow

UK

Form no.: UC453148UK – revision 06/2013

Table of contents Page

Spare parts, see seperate spare parts list

1. General description 21.1 Intended Use 2

2. Sectional drawing 3

3. Warnings 4

4. Introduction 64.1 The UC range 64.2 The UC pump, standard and auxiliary equipment 64.3 Identificationofpumpmodels 64.4 Identificationofmotormodels 64.5 Handling and Transport 74.6 Weights 7

5. Installation of pump 85.1 Positioning 85.2 Lining up the pipe system 85.3 Power supply 85.4 Liquidsupplyforflushedshaftseal 85.5 Connectingsteamandsteamcondensateforasepticuse 8

6. Start-up and operation 96.1 Checkingthepumpforforeignmaterial 96.2 Checkingthepump 106.3 Starting the pump 106.4 Flushing liquid 10

7. Service and maintenance 117.1 Checkingtheshaftseal 117.2 Replacingtheshaftseal 117.3 Replacingthemotor 137.4 Recommendedinventoryofspareparts 14

8. Technical data 15

8.1 Soundpressureandsoundeffectlevel 158.2 MaximumpermissibleoutletpressureforUCpumps 168.3 Tightening torques 168.4 Cleaningrecommendation 16

1

WCB

Page 3: CENTRIFUGAL PUMP - AxFlow

UK

Form no.: UC453148UK – revision 06/2013

1. General description

Thisoperatingmanualshouldbereadcarefullybythecompetentoperatingandmaintenancepersonnel.

Wepointoutthatwewillnotacceptanyliabilityfordamageormalfunctionsresultingfromthenon-compliancewiththisoperatingmanual.

Descriptionsanddatagivenhereinaresubjecttotechnicalchanges.

1.1 Intended useThecentrifugalpumpUCisexclusivelyintendedforpumpingliquids,especiallyinbeverageandfoodinstallations.

Its use is permissible only within the admissible pressure and temperaturemarginsandunderconsiderationofchemicalandcorrosiveinfluences.

Anyuseexceedingthemarginsandspecificationssetforthisconsideredtobenotintended.

Anydamageresultingtherefromisnotwithintheresponsibilityofthemanufacturer.Theuserwillbearthefullrisk.

Caution! Improperuseofthepumpleadsto: -damage -leakage -destruction -failuresintheproductionprocessarepossible

2

WCB

Page 4: CENTRIFUGAL PUMP - AxFlow

UK

Form no.: UC453148UK – revision 06/2013

2. Sectional drawing

1a pump housing2a capnut3 o-ring4 impeller6 o-ring7a backplate8 locatingpin9a clampring10 o-ring11 shaft14 extensionframe

5.1 fasteningkitforsinglemech.seal

5.3 pressure ring5.4 drain pipe5.5 o-ring5.6 stationarysealface5.7 rotarysealface5.8 pin5.9 fasteningkitdouble

mech.seal5.10 o-ring5.11 pressure ring

Section1:singlemechanicalshaftsealforshaftsØ25andØ35Section2:doublemechanicalshaftsealforshaftsØ25andØ35Section3:singlemechanicalshaftsealforshaftsØ55Section4:doublemechanicalshaftsealforshaftsØ55

Section 1

Section 3

Section 2

Section 4

3

WCB

Page 5: CENTRIFUGAL PUMP - AxFlow

UK

Form no.: UC453148UK – revision 06/2013

3. Warnings

1. Readthroughtheinstructionsbeforeinstallingthepumpandstartingitup.Ifindoubt,contactyourlocalSPXFlowTechnologyrepresentative.

2. Checkthatthespecificationsofthemotorandmotorcontrolunitarecorrect.Thisappliesinparticularforapplicationswithriskofexplosion.

3. Observethatapumpmaybeunstableandmaytilttotheforeonto its inlet port when having a relatively small motor and being assembledonbracketsinsteadofbeingequippedwithaframewithadjustablefeet.Becarefulduringtheinstallationofsuchapump.(Forthisreason,theUC/600/420pumpisequippedwithananti-tilting unit.)

4. Donotstartthepumpbeforeallpipeconnectionshavebeenfittedcarefullyandtightened.Specialprecautionsmustbetakenwhenthepumpisusedtopumphotand/orhazardousliquids.Insuchcasesfollowthelocalregulationsforpersonalsafetywhenworkingwiththeseproducts.

5. Donotstartthepumpbeforethemotorshroudorshaftguardhasbeensecurelyfitted.

6. Thepumpcontainsrotatingparts.Neverputyourhands,fingersorobjectsintoapumpwhileitisinoperation.

7. Nevertouchtheshroudduringoperation,asitcanbecomeveryhot.

8. Nevertouchthepumpbodyduringoperationifthepumpisbeingusedforhotmediawherethereistheriskofburning.

9. Nevercloseboththeintakeandoutletvalveofthepumpwhileitisinoperation.Ifthepumprunswithliquidinitwithoutcirculation,theliquidwillheatupandmayturnintovapour,causingtheriskofexplosion.

10. Alwaysremoveallassemblyandauxiliarytoolsfromthepumpbeforestartingitup.

11. Neverhosedownorcleantheelectricmotordirectlywithwaterorcleaningfluid.

12. Neverliftthepumpattheshroud,asitisnotdesignedtocarrytheweightofthemotor.Removetheshroudbeforeliftingthepump.Alwaysusesecurelyfittedliftingstrapswhenliftingwithacraneorsimilarliftinggear.

13. Neverdismantlethepumpbeforethemotorhasbeendisconnectedfromthepowersupply.Removethefusesanddisconnectthecablefromthemotorterminalbox.

14. Allelectricalinstallationsmustbecarriedoutbyqualifiedpersonnel.

4

WCB

Page 6: CENTRIFUGAL PUMP - AxFlow

UK

Form no.: UC453148UK – revision 06/2013

3. Warnings

15. Neverdismantlethepumpuntilthepipesystemhasbeendrained.Rememberthatliquidwillalwayscollectinthepumpbody.Ifthepumpistobeusedforhotand/orhazardousliquids,specialprecautionsmustbetaken.Insuchcasesfollowthelocalregulationsforpersonalsafetywhenworkingwiththeseproducts.

16. Thefollowingvaluesspecifiedforthepermissiblepressuremustnotbeexceeded:Max. 18 bar UC/008/110, UC/020/140, UC/080/170,

UC/055/180,UC/035/175,UC/130/290Max.14bar UC/210/290,UC/120/175,UC/600/420,

UC/008/200, UC/035/210, UC/060/220, UC/110/230, UC/350/260, UC/040/240, UC/080/255

Thea.m.valuesarealsovalidforcorrespondingmodelsoftheUCaandUCiranges.Itisimportanttorememberthatthevaluesforthemaximumoutletpressureapplytowateratatemperatureof20°C.

5

WCB

Page 7: CENTRIFUGAL PUMP - AxFlow

SPX Flow TechnologyHermana Frankego 9, 85-862 Bydgoszcz POLAND

XXXXXX

UC/20/140 125

3544312

UK

Form no.: UC453148UK – revision 06/2013

4. Introduction

4.1 The UC rangeThismanualcoversthestandardversionsoftheUCpumpaswellastheasepticversions–UCaandpumpswithinducer–UCi.Checkthepump'snameplatetoensurethatyouhaveoneoftheaboveversions.TheUChisdescribedinaseparatemanualwhichis supplied with the pump.

4.2 The UC pump, standard and auxiliary equipmentStandard options:

- withorwithoutmotorcover - withframeandfeetorfirmsupports - withshaftsealincarbon/SiCorSiC/SiC - witho-ringsinEPDMorFPM(Viton) - withsinglemechanicalordoublemechanicalseal,preparedfor

water-flushedorsteam-flushedshaftseal(UCa)

Additional options: - heating/coolingjacket - casingdrain - soundabsorbingmotorcover - pumpcart - inducer(UCi) - doubleo-ringsealofpumphousing,preparedforsterileflushing

(UCa) - heavydutyclampring,increasingthepump'smaximumpermissible

outletpressureto25bar(availableforUC/120/175,UC/035/210,UC/060/220,UC/110/230,UC/040/240)orto20bar(availableforUC/080/255).

- UCpumpscanbesuppliedwithallstandardweldedferrulessuchasunions,clampringsorflanges.

4.3 Identification of pump modelsAnameplateasshowninFig.1isfittedontheextensionframe.ExampleTypeUC/020/140: Specifiesthepumpmodel,here:UC/020/140.125: Indicatesthediameteroftheimpeller.SerialNo.: Indicatestheseriesnumberofthepump.OrderNo.: SpecifiestheSPXFTordernumber.Year: Showstheyearofmanufacture.Theemptyfieldcanbeusedtoidentifythepumpwithinaninstallation.

4.4 Identification of motor modelsAnameplateasshowninFig.2isfittedonthemotor.Theplateindicatesthemotortypeandheightofconstruction(pos.2),motorcapacity(kW)(pos.1)andspeed,etc.

Fig. 1

Fig. 2

6

WCB

Page 8: CENTRIFUGAL PUMP - AxFlow

UK

Form no.: UC453148UK – revision 06/2013

4. Introduction

4.5 Handling and TransportActwithcautionwhenliftingthepump.Allpartswithaweightofmorethan20kgmustbehandledwithasuitablehoistingdevice.Useacrane,fork-lifttruckoranothersuitablehoistingdevice,alwaystogetherwith2liftingropes(Fig.3).Placethehoistingbeltsaroundtherearpartofthemotorandaroundtheextensionframe.Takecarethatthebeltsareevenlyloadedwhenthepumpislifted.

Caution! Alwaysuse2hoistingbeltsandneverfastenthematthefrontpumpbody.

4.6 Weights

Fig. 3

Pump type

Motor80 90 100 112 132 160 180 200 225 250 280

0.75 kW 1.1 kW

1.5 kW 2.2 kW

3.0 kW 4.0 kW5.5 kW 7.5 kW

11.0 kW 15.0 kW 18.5 kW

22.0 kW30.0 kW 37.0 kW

45.0 kW 55.0 kW75.0 kW 90.0 kW

UC/008/110 20 20 --- --- --- --- --- --- --- --- --- ---

UC/020/140 28 29

33 36 41 46 57

62 --- --- --- --- --- ---

UC/080/170 --- 53 56 61 66 77

82

117 127 138

--- --- --- --- ---

UC/210/290* --- --- --- --- ---169 184 194

212 282 295 349 --- ---

UC/035/175 --- 36 39 44 49 60

65

100 109 117

--- --- --- --- ---

UC/055/180 --- 51 51 59 64 75

80

114 123 133

--- --- --- --- ---

UC/120/175 --- 59 62 67 71 83

88

125 135 145

170 236 249 --- --- ---

UC/600/420 --- --- --- --- --- --- 295 360 381 426 485 570

605

UC/008/200 --- 45 48 53 58 69

73 --- --- --- --- --- ---

UC/035/210 --- 54 59 66 71 82

87

127 136 147

--- --- --- --- ---

UC/060/220 --- 61 64 71 76 88

93

127 136 146

171 226 251 --- --- ---

UC/110/230 --- 68 71 76 82 94

99

132 141 151

176 225 250 295 --- ---

UC/350/260 --- --- --- --- 132 137

171 180 190

220 295 330 363 420 505

540

UC/040/240 --- 75 78 83 87 99

104

138 148 158

183 238 263 --- --- ---

UC/080/255 --- 83 83 89 95 107

112

146 155 165

190 265 280 335 395 ---

UC/130/290 --- --- 105 109 118 123

160 173 183

218 276 300 355 415 500

535

* only 1500 rpm

Theweightsindicatedaboveareforstandardpumpswithmotorshrouds.Theweightscanvarydependingonaccessoriesandfittingsandshallbeconsideredasreferencevalueforhandling,transportandpackaging,only.

7

WCB

Page 9: CENTRIFUGAL PUMP - AxFlow

UK

Form no.: UC453148UK – revision 06/2013

5. Installation of pump

5.1 PositioningThefollowingaspectshavetobeobserved: Thepumpmustbepositionedsothatthesuctionpipeisasshortaspossibleandthereisaslopinggradienttowardsthesuctionportofthe pump.Keepthenumberofvalves,bendsandtee-piecesonthesuctionside to an absolute minimum.Theremustbesufficientspacearoundthepumpforpipingandaccessformaintenance.

5.2 Lining up the pipe systemLineupthepipescarefullytothesuctionanddischargeportsofthepump.Makesurethatthepipesystemisadequatelysupportedbypipesupportssothatthepumpbodyisnotsubjecttostrainsandweightfromthepipesystem.

Note! Duringthesuctionprocess,thepumpmaytendtovibrate.Apipesupportshouldbeplacedclosetothepumpsuctiontopreventpipeworkvibrationcreatingexcessivenoise.

5.3 Power supplyThemotormustbeconnectedviaacontrolcabinettothenetworkincompliancewiththelocalregulations.Moreover,themotormustbeconnectedinaccordancewiththeinstructionsindicatedintheinnersideoftheconnectingboxlidofthemotor.Themotorshouldbeconnectedsuchthattherotatingdirectionofthemotorandthustheimpelleriscounter-clockwisewhenviewedfromthefronttowardsthesuctionportofthepumpbody(Fig.4).

5.4 Liquid supply for flushed shaft sealPumpswithflushedshaftsealhavetwoPTFEhoseconnectorsonthesealflange.Thehoseconnectorsare1/8inchandfit6.0mmhoses.Therequiredflowquantityamountsto15–30l/h.The maximum permissible pressure is 7 bar.

Thehoseconnectionshouldalwaysbepositionedverticallywiththefluidinletbelowandtheoutletabove(Fig.5).Fluidconsumptioncanbelimitedbyinstallingasolenoidvalveonthesupplyside.Theopen/closefunctionofthesolenoidvalvecanbecontrolledbythepump'sstart/stopsequence.Donotusesteamorsteamcondensateattheconnectionforflushingliquids.Ifyouwanttousesteamassealingmedium,aspecialasepticpipeconnectormustbeused. Connectorssee5.5.

5.5 Connecting steam and steam condensate for aseptic useWhenstaticdoublesealsareused,theconnectionforsteamorsteamcondensateatthepumpbodyisprovidedwithfittingsfor8 mm stainless steel pipes.Steamwithupto150°Cand5barcanbeused.

Fig. 4

Fig. 5

8

WCB

Page 10: CENTRIFUGAL PUMP - AxFlow

UK

Form no.: UC453148UK – revision 06/2013

6. Start-up and Operation

Beforestartingthepump,dismantleandcleanthesuctionpipe. Anyforeignmaterialinthepumpshouldberemoved.

6.1 Checking the pump for foreign materialRemovethepumpbodyasdescribedbelow.Thesectionaldrawing(page3)istobeusedforreference.

1. Disconnectthepowersupply.

2. Removethepumpbody(items1a,1b)byundoingtheclampring(pos.9a)orbodyscrewsandcarefullypulloffthepumpbody.

3. Turntheimpeller(item4)toensurethatthereisnoforeignmaterialbehind it.

4. Ifthereisanyforeignmaterialinthepump,removeit.

5. Whenthepumpbodyiscleanandfreeofforeignmaterial,reassemble the pump.

Mountthepumpbodyasdescribedbelow:

6. Checkthatthelocatingpin(item8),wherefitted,inthetopofthebackplate,mateswiththedetentinthepumpbodyandcarefully(toavoiddamagetotheo-ring)pressthepumpbody(item1a,1b)inovertheo-ring(item6)andfastenwiththeclampring(item9a)orbodyscrews,observingthecorrecttighteningtorque.

M10: max.35Nm(25ft-lb)

7. Installsuctionanddischargepipes.Checkthatthepipeunionshavebeentightenedproperlyandthatpipesupportshavebeenfitted.

Tomakethefrontcoverandthepumphousingeasiertofit,werecommendtoprovidetheo-ringwithathinlayeroffoodapproved,acid-freegreaseorsoap.

9

WCB

Page 11: CENTRIFUGAL PUMP - AxFlow

UK

Form no.: UC453148UK – revision 06/2013

6. Start-up and Operation

6.2 Checking the pumpTocheckthatthepumpisworkingsatisfactorily,pourwaterintothepumpandstartitforamoment.Checkthedirectionofrotation.Fig.6.Listenforanyunusualnoises.Inpumpswithwater-flushedorsteam-flushedshaftseals,thesealchambermustbefilledwithwater/steam.

Caution! Neverallowthepumptorunwithoutliquid,asthiswillruintheshaftseal.

6.3 Starting the pumpCheckthefollowingbeforestartingthepump:

- thattheshaftguardhasbeenfittedproperly. - thatthereisfreeaccessforliquidandthepumpisprimed. - thatthevalveonthedischargesideisclosed.

Thevalveonthedischargesideisclosedduringstart-uptopreventthemotorfromoverloading,butshouldbeopenedagainassoonasthe pump has been started.

Note! Thepumpshouldnotbeleftrunningtoolongwithoutpumping(typically15minutes,ifthepumped liquid is not hot), as it gets warm and loses priming liquid by evaporation.

6.4 Flushing liquidInpumpswithflushedshaftseal,checkthatthesupplyofflushingmediumisopenandthattheflowofthemediumisadequate(about 15–30 litre/hour).

Fig. 6

10

WCB

Page 12: CENTRIFUGAL PUMP - AxFlow

UK

Form no.: UC453148UK – revision 06/2013

7. Service and Maintenance

7.1 Checking the shaft sealCheckthepump'sshaftsealforleaksonaregularbasis.Iftheshaftsealisleaking,replaceitoritsrelevantpartsasdescribedbelow.

7.2 Replacing the shaft sealThesectionaldrawing(page3)showsthepositionandconstructionoftheshaftseal–bothordinarysealsandsealswithliquid/steamflushing.

Toreplacetheshaftsealitisnecessarytodismantlethepump.Followthestepsdescribedbelowandrefertothesectionaldrawing (page 3).

1. Disconnectthepowersupplyinthemotorisolatorbyremovingthefusesanddisconnectingthecables.

2. Turnoffthesteamandflushingliquidsupply.

3. Closethesuctionanddischargeofthepumpanddrainthepumphousing.Ifthepumpisusedforhotand/oraggressiveliquids,specialprecautionsmustbetaken.Insuchcases,observethelocalregulationsforpersonalprotectionwhenworkingwiththeseproducts.

4. Opentheclampring(item9a)orthehousingscrews,oncetheinletand outlet pipes have been properly isolated. Dismantle the pump housing (item 1a, 1b) and remove the impeller (item 4).

5. Takethestationarysealface(item5.6)installedinthebackplate(item7a,7b)outwithyourfingers.

6. Removetheo-ring(item5.5)fromthestationarysealface.

7. Taketherotarysealface(item5.7)installedintheimpeller(item4)outwithyourfingers.

8. Removetheo-ring(item5.5)fromtherotarysealface.

9. Cleanthechambersofthestationaryandrotarysealfacewithairor water.

9a Inthecaseofwater-flushedshaftsealsandasepticshaftseals,dismantlethebackplateforthedisassemblyoftherearshaftseal.Therearstationarysealface(item5.6)ismountedtothepressurering*(item5.11).Therotarysealface(item5.7)ismountedtotheshaft(item11).Theseareremovedinthesamewayasthefrontsealcomponents.*TheUC/600/420pumphas2identicalpressurerings.

Dismantling the pump

Dismantling the shaft seal

11

WCB

Page 13: CENTRIFUGAL PUMP - AxFlow

UK

Form no.: UC453148UK – revision 06/2013

7. Service and Maintenance

10. Checktheo-ringsforsignsofstiffness,lackofelasticity,brittlenessand/orchemicalattack.Replacewornordamagedparts.

11. Checkthestationaryring(item5.6)androtaryring(item5.7)forsignsofwear.Wearsurfacesmustbecompletelyfreeofcracks.Ifthisisnotthecase,both–thestationaryringandtherotaryring–mustbereplaced.

11aInthecaseofwater-flushedshaftsealsandasepticshaftseals,checktherearsealrings(item5.6,5.7)forwear,andreplaceifnecessary.

12. Fitthenewo-ringsonthestationarysealfaceandrotarysealface.

Note! Remember to moisten these with water.

13. Fittherotarysealfaceontheimpellerwithoutusingtools.

Note! Thenotchintherotarysealfacemustbefittedso that it mates with the driving pin (item 5.8) in the impeller hub.

13aInthecaseofdoublemechanicalshaftseals,alsofitarotarysealface(item5.7)witho-ring(item5.5)inthelocationontheshaft–again without using tools.

14. Fitthestationarysealfaceinthebackplatewithoutusingtools.

Note! Fixthestationarysealfacesothatitfitstothepininthebackplate.Checkthatthestationarysealfaceispositionedsothatitslidesbackandfortheasilywithinthebackplate.

14aWhenfittingnewdoublemechanicalshaftseals,removethedrainpipe(item5.4)beforefittingtheminthepressurering(itemitem5.9)orbackplate(item7a,7b).* The UC/600/420 pump is not equipped with a drain pipe.

15. Afterfitting,cleanthewearingsurfaces.

15aFordoublemechanicalshaftseals,re-mountthebackplate(item 7a, 7b).

16. Fit the impeller (item 4). Remember to use the proper tightening torque. M10: 45Nm(33ft-lb) M14: 70Nm(52ft-lb) M20: 200Nm(148ft-lb)

17. Checkthatthelocatingpin(item8)inthetopofthebackplate,mates with the detent in the pump body. To avoid damaging the o-ring,carefullypressthepumpbody(item1a,1b)inovertheo-ring(item6)andfastentheclampring(item9).

Remember to use the proper tightening torque:M10: max.35Nm(25ft-lb)

Checking parts for wear

Fitting

12

WCB

Page 14: CENTRIFUGAL PUMP - AxFlow

UK

Form no.: UC453148UK – revision 06/2013

7. Service and Maintenance

7.3 Replacing the motorThestandardmotoroftheUCpumphasalockedfrontbearing.Ifthemotorisreplaced,thenewmotormustalsohavealockedfrontbearing.Themotorbearingisenclosedandpermanentlylubricated.

Themotorisequippedwithfeetandflanges:“smallflange”(B34)forframesizes,“largeflange”(B35)forframesizeandlarger.

Whenreplacingthemotor,followtheinstructionsbelow.Forthereplacementofbearings,seethemotorsupplier'sserviceinstructions.

1. LockOutpowersupply,thendisconnectthepumpandmotorfromsystem.

2. Removethepumpbody.See7.2,paragraph1-4.

3. Dismantle the impeller.

4. Removethemotorshroudand,ifpossible,placethepumpverticallyonthemotor'sfancover.Fig.7.

5. Releasethefourmotorflangescrewsandremovethem(Fig.7).

6. Liftthebackplate(item7)andextensionframewhicharestillboltedtogether,upandofftheshaft.SeeFig.10. Removethespacerflange(item17)(wherefitted).

7. SeeFig.8.Loosenthescrewsinthebaseofshaft,pulltheshaftoffandreplacethemotor.

8. SeeFig.9.Beforemountingthenewpumpshaft,removeanydirtandgreasefromthemotorshaftandthebase'sinternalclampingsurfaces.Mountthepumpsshaftloosely.Positionthebalanceholeoverthekeyway.

9. Fitthebackplateandextensionframeovertheshaft.

10. Tighten the bolts.

11. Standthepumpbackonitslegs/brackets.

12. Fittheimpellerandsecureitwiththecapnut/inducer.

Remember to use the proper tightening torque:M10: 45Nm(33ft-lb)M14: 70Nm(52ft-lb)M20: 200Nm(148ft-lb)

Fig. 7

Fig. 8

Fig. 9

Rearflange

Screw

Extensionframe

Motor

Shaft

Screw

Motor

Keyway

Motorshaft

Balancehole

Pumpshaft

13

WCB

Page 15: CENTRIFUGAL PUMP - AxFlow

UK

Form no.: UC453148UK – revision 06/2013

7. Service and Maintenance

13. Placetheplasticstaragainsttheimpeller.Fig.10.

14. Fitthepump/screwhousingandfastenwiththeclampring.

15. Pushtheshaftforwarduntiltheimpelleristouchingtheplasticstar.See Fig. 11.

16. Tightentheshaftscrews(item11). Remember to use the proper tightening torque: M8: 30Nm(22ft-lb) M10: 55Nm(41ft-lb) M12: 80Nm(59ft-lb) M16: 180Nm(132ft-lb)

17. Remove the star by pulling it out through the inlet.

7.4 Recommended inventory of spare parts

Seal kitsWerecommendthatyoukeepbothsealkitsandservicekitsfortheUCpumpsinstock.ThesealkitfortheUCpumpconsistsofthewearingpartsofthepump,asspecifiedinthesparepartslist.

Numberofpumpsinservice0–5 5–20 >20

Sealkits number number kits/10pumps

Normaloperation 2 3 1Specialneeds 3 6 2

Service kitsTheservicekitismadeupofanumberofthemaincomponentsofthepumpwhicharenotwearingparts,butwhichyoustillmayhavetoreplace:shaft,impeller,capnutandfixingkit.

Numberofpumpsinservice0–5 5–20 >20

Servicekits number number kits/10pumps

Normaloperation 0 1 1Specialneeds 1 2 1

Fig. 10

Impeller

Plasticstar

Pump body

Fig. 11

14

WCB

Page 16: CENTRIFUGAL PUMP - AxFlow

UK

Form no.: UC453148UK – revision 06/2013

8. Technical Data

8.1 Sound pressure and sound effect levelMeasurementshavebeencarriedoutinaccordancewithISO3743,Grade2andISO3746,Grade3.Tolerance:±3dB.

LpAindBreferstothesoundpressurelevelatadistanceofonemeterfromthesurfaceofthepumpataheightof1.6mabovefloorlevel(cf.ECDirective(89/392/EEC).

Lwa states the sound power level.OperatingconditionsA,BandCaredefinedasfollows:

a) Nominalflowandmax.permissibleoperatingpressureb) Nominalflowand60%operatingpressurec) 60%flowandmax.permissibleoperatingpressure

Thenominalflowandmax.permissibleoperatingpressureinthecaseoftheUC/060/220,forexample,are60m³/hratanoperatingpressureof5.5bar,andsoon.

ThisinformationonlyappliesifthemotorusedisanABBaluminiummotorandthesizeofthemotormatchesthepowerrequirementofthe pump.

Thenoiselevelmayincreaseconsiderably,ifreducers(reduction/expandingfittings)aremountedattheinlet/outlet.

Thevaluesshownapplywhenthepumpsrunat2900rpmandhaveashroudoverthemotor.Ifthepumpsarerunat1450rpm,thevaluesarereducedbyabout20dB.ThevaluesfortheUC/210/290applyat1450rpm.

Operating conditions

LpA LwAA B C A B C

UC/008/110 65 62 60 79 77 74UC/020/140 67 65 61 81 79 75UC/080/170 75 73 68 89 87 82UC/210/290 69 68 64 83 82 78UC/035/175 69 67 64 83 81 78UC/055/180 72 70 67 86 84 81UC/120/175 76 74 72 90 88 86UC/008/200 69 68 64 83 82 78UC/600/420 75 75 73 89 89 87UC/035/210 69 68 68 83 82 82UC/060/220 74 70 68 88 84 82UC/110/230 76 74 72 87 85 84UC/350/260 86 88 82 100 102 98UC/040/240 75 69 69 89 83 83UC/080/255 75 73 72 89 87 86UC/130/290 79 76 76 93 90 90

Please observe that the sound emitted by a pump varies a lot. It depends on the pump design (size/speed/shroud/installation) as wellasontheliquidtypeandpumpingconditions.

15

WCB

Page 17: CENTRIFUGAL PUMP - AxFlow

UK

Form no.: UC453148UK – revision 06/2013

8. Technical Data

8.2 Maximum permissible outlet pressure for UC pumpsThemaximumpumpoutletpressurespecifiedbelowmustnotbeexceeded(appliestowaterat20°C).

Max. 18 bar: UC/008/110, UC/020/140, UC/080/170, UC/055/180, UC/035/175,UC/130/290

Max. 14 bar: UC/210/290,UC/120/175,UC/600/420,UC/008/200, UC/035/210, UC/060/220, UC/110/230, UC/350/260, UC/040/240, UC/080/255

TheabovevaluesalsoapplyforthecorrespondingmodelsoftheUCa and UCi design.

8.3 Tightening torquesRequiredtorquestotightenthepumpshaftonthemotorshaft:M8: 30Nm(22ft-lb)M10: 55Nm(41ft-lb)M12: 80Nm(59ft-lb)M16: 180Nm(132ft-lb)

Note! Makesurethatthekey-grooveofthemotorshaftistobeseenthroughtheholeinthestubshaft.Fig. 12.

Requiredtorquetotightenthecapnutandtheinducer:M10: 45Nm(33ft-lb)M14: 70Nm(52ft-lb)M20: 200Nm(148ft-lb)

Requiredtorquetotightentheclampconnectionatthepumpbodyandbodycover:M10: max.35Nm(25ft-lb)

8.4 Cleaning recommendationTheproduct-wettedpartsofthepumpsarecleanedbythecleaningliquidoftheconnectedpipelines.Dependingonthedegreeandconstituentsofsoiling,cleaningliquids,timesandcyclesmustbeadjustedfortheindividualapplication.Verifythecompatibilityoftheindividuallyselectedcleaningprocessesandliquidswiththerespectivelyusedsealmaterials.

Subjecttochange.

Fig. 12

16

WCB

Page 18: CENTRIFUGAL PUMP - AxFlow

UCCE NTR I FUGAL PU M P

Translated operating manual

S PX Flow Technology Poland sp. z o.o.

Hermana Frankego 9

85-862 Bydgoszcz, Poland

P: (+48) 52 525 9900

F: (+48) 52 525 9909

SPX reserves the right to incorporate design and material changes

without notice or further obligation.

Design features, materials of construction and dimensional data,

as described in this bulletin, are provided for your information only

and should not be relied upon unless confirmed in writing. Please

contact your local sales representative for product availability in

your region.

For more information please visit www.spx.com.

ISSUED 06/2013 –

COPYRIGHT © 2013 SPX Corporation