    Controls,Air Conditioning& Refrigeration Products

  • 8/15/2019 CD-JCI-GENCAT-2007

    2/207

    THE POWER OF BLUE

  • 8/15/2019 CD-JCI-GENCAT-2007

    3/207

    Company Prole

    Johnson Controls has expanded remarkably since

    Professor Warren Johnson founded the company

    to manufacture his invention, the electric room

    thermostat. Since its start in 1885, Johnson Controls

    has grown into a global leader in automotive

    experience, building efciency and power solutions.

    The company provides innovative automotive interiors

    that help make driving more comfortable, safe andenjoyable. For buildings, it offers products and services

    that optimize energy use and improve comfort and

    security. Johnson Controls also provides batteries for

    automobiles and hybrid electric vehicles, along with

    systems engineering and service expertise.

    Our Vision

    A more comfortable, safe and sustainable world.

    Our Values

    Integrity

    Honesty, fairness, respect, and safety are of the

    utmost importance.

    Customer Satisfaction

    Our future depends on us helping to make our

    customers successful. We are proactive and easy

    to do business with. We offer expert knowledge and

    practical solutions, and we deliver on our promises.

    Employee Engagement

    We foster a culture that promotes excellent

    performance, teamwork, inclusion, leadership and

    growth.Innovation

    We believe there is always a better way. We encourage

    change and seek the opportunity it brings.

    Sustainability

    Through our products, services, operations and

    community involvement, we p romote the efcient use

    of resources to benet all people and the world.

    A more comfortable, safe and sustainable world.

  • 8/15/2019 CD-JCI-GENCAT-2007

    4/207

    Controls

    Electronic Control Devices

    Programmable Digital ControllerFX06 Compact Controller - 24VAC Power SupplyFX07 Field Controller - 24VAC Power SupplyFX07 Field Controller - 90 - 240VAC Power SupplyFX14 Field Controller - 24VAC Power SupplyFX15 “Classic” Field Controller - 24VAC Power SupplyFX15 “Universal” Field Controller - 24VAC Power SupplyFX16 Master Controller - 24VAC Power SupplyMD20 Master Display - 24VAC Power SupplyAccessories - Network Room Sensor ModuleAccessories - Medium User Interface (MUI) DisplayAccessories - Extension and Expansion I/O ModulesAccessories - MultimediaAccessories - SoftwareSystem 91 N2. DX-9100 ControllerSystem 91 N2. XTM Extension/Expansion I/O Modules

    System 91 N2. Terminal Unit Controller TC-910x Series

    LonWorks® Digital ControllersTerminal Unit Controller TCU Series – 24VAC Power Supply – 2 Pipe FCU ApplicationsTerminal Unit Controller TCU Series – 24VAC Power Supply – 4 Pipe FCU ApplicationsTerminal Unit Controller TCU Series – 24VAC Power Supply – Chilled Ceiling ApplicationsTerminal Unit Controller TCU Series – 230VAC Power Supply – 2 Pipe FCU ApplicationsTerminal Unit Controller TCU Series – 230VAC Power Supply – 4 Pipe FCU ApplicationsTerminal Unit Controller TCU Series – 230VAC Power Supply – Chilled Ceiling ApplicationsIntegrated Room Control AD-FCC, AD-FCD and AD-IRC Controller Series – 230VAC Power Supply

    ContentsRoom Sensors and Thermostats

    TM-1100 Room Command Module

    TM-2100 Room Command Module

    RS-1100 Room Command Module

    A99 Room Sensor

    HT-9000 Room Sensor 

    LP-NRM Room Command Module

    AD-RCM Room Command Module

    AD-IRM Room Command Module

    TC-8900 Room Thermostat

    TEC Networked Room Thermostat

    Plant SensorsTS-9100 Temperature Sensor

    TE-9100 Temperature Sensor

    HT-9000 Humidity and Temperature Sensor

    HX-9100 Dew Point Sensor

    PS-9101 Differential Pressure Sensor

    PT-5215 Differential Pressure Sensor

    PT-5217 Pressure Sensor

    Metasys Extended ArchitectureMSEA

    M3i

    M3i - System Network Layout

    TDS Line - Touch Screen Displays

    Metasys - System Network Layout

    P 2000 - System Network Layout

    JCI Building Efciency as Solutions Supplier

    Valves and Actuators

    Terminal Unit Valves and ActuatorsTerminal Unit Valves and Actuators

    Threaded Control Valves and ActuatorsThreaded Control Valves and Actuators

    Flanged Control Valves and ActuatorsFlanged Control Valves and Actuators

  • 8/15/2019 CD-JCI-GENCAT-2007

    5/207

    Security

    Security Management SystemCardkey® P2000LECardkey® P2000Access Control ControllersS300-DIN-RDR2SA

    DVN Range of productDVN5000 Code Number LegendDVN5000 Real Time Ver. 2.5 & aboveDVN5000 Multiplexed ver. 2.5 & aboveDVN5000 IP/Network Only DVN’s ver. 2.5 & aboveDVN5000 Multiplexed Ver. 2.3DVN3000 SeriesDVN100 Encoder/Decoder SeriesDVN Software

    External Storage OptionsExample of DVN Architecture

    Rotary Actuators

    Small Family / Silence FamilyM9102 /M9104-AGA-xSM9304-Axx-1N ON/OFFM9304-GxA-1N

    New Standard Family

    M9108 / M9116 / M9124 / M9132-Axx-1N ON/OFF and Floating actuatorsM9108 / M9116 / M9124 / M9132-GGx-1N Proportional Actuators AC/DC 24 VM9108 / M9116 / M9124-GDx-1N Proportional Actuators AC 230 V

    Springback FamilyM9206-Bxx-1S ON/OFF ActuatorsM9206-GGX-1 Proportional ActuatorsM9210-Bxx-3 ON/OFF ActuatorsM9220-Bxx-3 ON/OFF Actuators

    Security FamilySFx ON/OFF Springback Actuators for Safety DampersSEx ON/OFF Actuators for Smoke DampersSFx (SLC) ON/OFF Springback Actuators for Fire DampersSFx (SLC) ON/OFF Springback Actuators for Fire DampersS9210 / S9220

    Valve FamilyM9108-Axx-5 ON/OFF and Floating Ball Valves ActuatorsM9108-GGx-5 Proportional Valves ActuatorsM9116-Axx-1N2 ON/OFF and Floating Mixer ActuatorM9116-GGx-1N2 Floating Mixer Actuators AC/DC 24V

    M9116-GDx-1N2 Proportional Mixer Actuator AC 230 VM9108-GDx-5 Proportional Ball Valves Actuator AC 230 V

    Special FamilyM9108 / M9116-xGx-1N4 Modulating Actuators AC/DC 24 VSA1.2x ON/OFF and Floating ActuatorsM9116-AAx-1 ON/OFF and Floating ActuatorsM9108/M9116/M9124-GAx-1.01 Current Controlled Damper ActuatorsM9108/M9116/M9124-GAx-1 ActuatorsSASx.30 ON/OFF and Floating ActuatorsSALx.30 ON/OFF and Floating Actuators

  • 8/15/2019 CD-JCI-GENCAT-2007

    6/207

    Refrigeration Controls

    Modulating Water ValvesV46 Pressure Actuated Water ValvesV46SA Two-way Pressure Actuated Water Valves, Low FlowV47 Two-way Temperature Actuated Water ValvesV48 Three-way Pressure Actuated Water Valves

    Refrigeration Field ControllersMR. Electronic Refrigeration ControlsMS. Single and Multistage controllers for Refrigeration, Heating, Humidity and PressureSystem 27 NOVA, One- and Two-stage Thermostat, without SensorSystem 27 NOVA, Display Modules, without SensorsSystem 27 NOVA Stage Modules, Incl. quick connectorSystem 27 NOVA Signal Converter

    Fan Speed ControllersP215 Pressure Actuated Single Phase Fan Speed ControllersP215 Direct Mount Pressure Actuated Direct Mount SingleP215 Pressure Actuated Single Phase Fan Speed ControllersU215LR 0-10 Vdc/4-20 mA Input Single Phase Fan Speed ControllersA255 Temperature Actuated Fan Speed Controllers for 3-phase MotorsU255 (0 - 10 V Input) Fan Speed Controllers for 3-phase MotorsP255 Single/Dual Input Pressure Actuated Fan Speed Controllers for 3-phase MotorsP35 Mechanical Pressure Transducer for P215 / P255 series

    Flow and Float ControlsF61 Flow Switches for LiquidF62 Air Flow SwitchesF63 Liquid Level Float Switches

    Pressure ControlsP232 / P233 Sensitive differential pressure controlP20 Pressure controlP28 Oil protection controlP45 Oil protection control

    P48 Steam pressure controlP74 Differential pressure controlP735 Single pressure controlP736 Dual pressure controlP77 Single pressure controlP78 Dual pressure controlP100 Direct Mount Pressure SwitchesH735 Synthetic Flexible Hose (accessories)

    Pressure TransducersP499 Electronic Pressure Transducer

    Refrigeration Temperature ControlsA19 Series IP30 - IP65, Capillary and Space ThermostatsA25 Series IP30, Rod and Tube Sensing Elemen tA28 Series IP30 - IP65, Two-stage Capillary and Space ThermostatsA36 Series, 3- or 4-stage Thermostats270XT Series Freeze Protection Control, IP30T22 and T25 One and Two-stage Room Thermostat, Line Voltage , IP20

  • 8/15/2019 CD-JCI-GENCAT-2007

    7/207

    VRF

    YDS Variable refrigerant flow systemR410A • YDMH 100, 140, 280, 335, 400, 450 CR407C • YDMH 100, 140, 280, 560, 840 B

    Air Systems

    RoomtopR407C • RTC-RTH 07 to 30 KR410A • RTC-RTH 07 to 30 L

    RooftopRooftop DIC-BIH-DIG 90 to 300 GLarge Rooftop DIC-BIH-DIG 360 to 480 G

    Large SplitAxial fan SOC-SOH 76 to 300 KCentrifugal fan SCOC-SCOH 70 to 300 K

    YKlonYKlon system applications

    Residential& Light CommercialAir-Conditioning Products

    Split Systems

    MinisplitHigh Wall Inverter Mimetech YVHC 09 to 12High Wall Power Inverter RVHC-E 09 to 24High Wall Inverter RVHC 09 to 18High Wall Inverter Single Split Type JSOI 25 to 45 BGHigh Wall High Efciency RACC-RAHC 07 to 28High Wall Fixed Speed YJCC-YJHC 09 to 24High Wall Single Split Type JSO 20 to 60 BG

    MultisplitHigh Wall Multisplit RMHC 18-21 (2x1) · RMHC 27-30 (3x1)High Wall Multisplit HMHB 18-21 (2x1) · HMHB 27-30 (3x1)High Wall Multi Inverter Free Match RRHC 18 (2x1) · RRHC 27 (3x1)Multi Inverter Free Indoor Units RRJC 18 (2x1) · RRJC 27 (3x1) · RRJC 30 (4x1)High Wall Multi Inverter JSDI 50 (2x1) · JSYI 70 (3x1) · JSXI 75 (4x1)

    Minisplit Floor / CeilingConvertible Console Inverter YOHC-D 18 to 48Convertible Console YOHC 12 to 60Convertible Console YOCB-YOHB 18 to 60Split Floor/Ceiling JSF 70 to 140 BG

    Minisplit CassetteCassette Inverter YKHC-D 18 to 48Cassette YKHC 12 to 48Cassette YKCB-YKHB 12 to 48Cassette JSK 50 to 120 BG

    Minisplit BlowerBlower Inverter YUHC-D 18 to 48Blower YUHC 18 to 60Blower YUCB-YUHB 18 to 60

    Window & PortableWindow Y9USC/E 09 to 18 B5A/RPortable with electrical heater intergrated PBSC09FD / PBSC12FDPortable MV 29 BGR

  • 8/15/2019 CD-JCI-GENCAT-2007

    8/207

    Air Handling Systems& Terminal Devices

    Fan Coil UnitsFan coil with centrifugal fan 2 & 4 pipe system YFCM 130 to 740Fan coil with tangential fan 2 & 4 pipe system YFTM 130 to 540Fan coil LASER 2 & 4 pipe systemFan coil LOW BODY 2 & 4 pipe systemFan coil SAPHIR 2 & 4 pipe systemFan coil YGFC 02 to 14 STCassette 2 & 4 pipe system YKE 221 to 232 / 421 to 432Cassette 2 & 4 pipe system YHK 20 to 110High Wall HHY-HHH 05 to 11Convertible Console HCY-HCH 10 and 14Blower YEFB 130-440

    Air Handling UnitsYMA Custom Air Handling UnitsYMA-C Custom Air Handling UnitsYMD Modular Air Handling Units

    Close Control UnitsModular UnitsAir Cooled Twin Circuit UnitsDCS / FCS Chilled Water UnitsPlug Fan UnitsSmall SystemsUnit Options

    SmartPacSmartPac

    Chillers & Heat Pumps

    Scroll Compressor Chillers and Heat Pumps Air to WaterAir cooled chiller-Air to water heat pump YLCA-YLHA 5 to 40Air cooled chiller-Air to water heat pump YCSA 50 to 150HVS Digital Scroll Split version YDC_522H / YDC_972H / YOC_762H / YOC_1522H

    HVS Digital Scroll Compact versionYDC_522H-C / YDC_972H-C / YOC_762H-C / YOC_1522H-C

    Air cooled chiller & heat pump with centrifugal fan YLCC-2 42 to 152Hydro kit GH 200 to 600 for YLCC-2

    Scroll Compressor Chillers and Heat PumpsAir-Cooled & Water Cooled

    Tempo YLAE Air-Cooled Scroll Compressor ChillerTempo YLAE-HP Reverse Cycle Air to Water Heat Pump-ChillerZaro YCWL Water-Cooled or Remote Air-Cooled Scroll Compressor Chiller

    Screw Compressor Chillers Air-Cooled & Water CooledSymphony YCIV Air-Cooled Varia ble Speed Drive Screw Compressor ChillerYCSE Water-Cooled or Remote Air-Cooled Screw Compressor ChillerYLCS Water-Cooled or Remote Air-Cooled Screw Compressor ChillerYN Water-Cooled Screw Chiller Dry Cooler Application Heat Recovery ApplicationYR Water-Cooled Screw Compressor ChillerYNWS/RS Water-Cooled or Remote Air-Cooled Screw Compressor ChillerYNWH Water-Cooled Screw Chiller Brine Applications

    Centrifugal Compressor Chillers Water-CooledYK Water-Cooled Centrifugal Compressor Chiller

    Absorption Chillers Water-Cooled

    YMPC-F/EX Water Cooled Mini Paraow Direct Fired Absorption Chiller-HeaterParaFlow YPC-F Two-Stage Direct Fired Chiller-HeaterParaFlow YPC-ST Two-Stage Steam Fed Absorption ChillerIsoFlow YIA Single Stage Hot Water or Steam Powered Absorption ChillerEnergy Management & Chiller Sequencing

  • 8/15/2019 CD-JCI-GENCAT-2007

    9/207

    Refrigeration

    Control SystemsUnisab III Refrigeration systems controllerUnisab II-R Advanced control system for reciprocating compressorsSabvisual II Supervisory control and data acquisition (SCADA)Fixed-speed PAC chiller automation conceptComsabProfibus for Unisab II control systems

    Upgrading Unisab II. Advanced control system retrofit packagefor refrigeration compressors

    Condensing pressure optimiser for R717

    ISAC (Integrated Standard Application Concept) Control and managementof refrigeration systems

    Web-enable your refrigeration equipment

    Gas Detection SystemsUnisafe II ammonia detection equipmentUnisafe II HFC/HCFC detection equipmentUnisafe II propane detection equipment

    Spare Parts

    Reciprocating CompressorsCMO single-stageSMC 100 single-stageHPO/HPC high-pressureCO2/Ammonia Freeze Package (CAFP)Rotatune reciprocating compressorsTCMO/TSMC two-stage reciprocating compressorsChillPAC packaged ammonia chillers (Water chillers)ChillPAC packaged ammonia chillers (Brine chillers)PAC chillers with reciprocating compressors (Water chillers)PAC chillers with reciprocating compressors (Ethylene glycol chillers)PLCH chillers for R410A (Water chillers)PLCH chillers for R410A (Ethylene glycol chillers)

    Screw Compressors ChillersSABCube variable-speed screw compressorsSAB screw compressors (swept volumes 200–850 m3/h)SAB screw compressors (swept volumes 800–10,000 m3/h)Rotatune variable-speed screw compressorsChillPAC packaged ammonia chiller featuring SABCube screw compressor (Water chillers)ChillPAC packaged ammonia chiller featuring SABCube screw compressor (Brine chillers)PAC chillers with screw compressors (Water chillers)PAC chillers with screw compressors (Ethylene glycol chillers)

    Ice MachinesSabroe V/VD flake ice machines

  • 8/15/2019 CD-JCI-GENCAT-2007

    10/207

    We are the global leader in providing building automation systems, re

    and security systems and heating, ventilating and air conditioning (HVAC)

    equipment for non-residential buildings.

    Our customers include thousands of hospitals, schools, airports, ofce

    buildings, data centers, government facilities, high-tech manufacturing

    sites, pharmaceutical laboratories and other non-residential buildings.

    We partner with customers for the long-term, often over the entire

    life of a building. Many of our customer relationships span decades.

    For the residential buildings market, we provide air conditioning and

    heating systems.

    Acquisition of York International

    In 2006, the building efciency business recorded sales of $10.2 billion

    including the revenues from York International, a leading global supplier

    of HVAC equipment and services, which we acquired in 2006.

    The acquisition provides Johnson Controls with competitive advantage

    through our unique capability to provide a single source of integrated

    controls, re and security products, HVAC equipment and services to

    optimize building comfort and energy efciency anywhere in the world.

    Electronic Control Devices

    Valves & Actuators

    Rotary Actuators

    Security

    Refrigeration

    Johnson Controls makes buildings in 125 countries more comfortable,productive, safe and energy efcient.

    Expanded Offerings, Expanded Markets

    Johnson Controls and York have a combined existing customer list

    numbering in the tens of thousands. Selling our full range of systems,

    equipment and products to existing customers is a signicant opportunity

    for growth.

    Technology to Improve Efciency

    Automating and integrating critical building systems such as HVAC

    equipment, security and lighting improves the comfort and safety of buildings

    while increasing energy efciency and reducing costs. It also provides

    customers with a better view of all the aspects of their buildings and the

    related costs. We continue to enhance the performance of our industry-

    leading building automation systems. A few years ago, building operators

    would monitor and control building conditions through a dedicated desktop

    computer. Today, an operator can fully access and control the Metasys®

    system from any place in the world through a PDA, cell phone or the Internet,

    allowing building personnel to be more mobile and productive.

    Controls

  • 8/15/2019 CD-JCI-GENCAT-2007

    11/207

     C O N T R O L S

    Features• Freely programmable or congurable using FX Tools• Standalone or network installation (via optional communication module for N2Open

    or LonWorks® networks)• Status report via SMS (via optional RS232C communication module using a GSM modem)• Digital input transition counter and optional pulse width modulation (PWM) output• Integral 2-line LCD display with graphical icons – freely programmable• Choice of user interfaces, integral and optionally remote• Equipment panel mounting and connector cables for ease of factory installation

    • Multi-language database for display (up to 5 languages per application)

    Communication ModulesFX06 N2Open Communication Module LP-NET061-000CFX06 LonWorks® Communication Module LP-NET062-000CFX06 RS232C Communication Module LP-NET063-000C

    Mounting/Connection AccessoriesFX06 Cable Set (OEM applications) LP-KIT006-010CLink cable for the connection of the FX06to the Panel Mount MUI display – 3 m (9.8 ft) LP-KIT007-005C

    Electronic Control DevicesProgrammable Digital ControllerFacility Explorer

    FX06 Compact Controller – 24VAC Power Supply

    3+1 = 3 Interlocked Relays + 1 Free Relay

    I/O Details Accessories Included Ordering Code

       A   n   a

       l   o   g   u   e   I   n   p   u   t

       D   i   g   i   t   a   l   I   n   p   u   t

       A   n   a

       l   o   g   u   e    O   u   t   p   u   t

       P   W   M    O   u   t   p   u   t

       D   i   g   i   t   a   l    O   u   t   p   u   t

       (   R   e   l   a   y   s   )

       D   i   g   i   t   a   l    O   u   t   p   u   t

       (   T   r   i   a   c   s   )

       I   n   t   e

       g   r   a   t   e   d   D   i   s   p   l   a   y

       N   2    O

       p   e   n

        C   o   m

       m   u   n   i   c   a   t   i   o   n    C   a   r   d

         L     O     N     W     O     R     K     S

        ® 

        C   o   m

       m   u   n   i   c   a   t   i   o   n    C   a   r   d

       R    S   2

       3   2    C

        C   o   m

       m   u   n   i   c   a   t   i   o   n    C   a   r   d

        C   a   b

       l   e    S   e   t

    4 5 2 - 6 -   ●   LP-FX06P00-000C

    4 5 2 - 6 -   ● ● ●   LP-FX06P01-000C

    4 5 2 - 6 -   ● ● ●   LP-FX06P02-000C

    4 5 2 - 6 -   ● ● ●   LP-FX06P03-000C

    4 5 1 1 6 -   ●   LP-FX06P10-000C

    4 5 1 1 6 -   ● ● ●   LP-FX06P11-000C

    4 5 1 1 6 -   ● ● ●   LP-FX06P12-000C

    4 5 1 1 6 -   ● ● ●   LP-FX06P13-000C

    4 5 2 - 4 2   ●   LP-FX06P20-000C

    4 5 2 - 4 2   ● ● ●   LP-FX06P21-000C

    4 5 2 - 4 2   ● ● ●   LP-FX06P22-000C

    4 5 2 - 4 2   ● ● ●   LP-FX06P23-000C

    4 5 2 - 3+1 2   ●   LP-FX06P30-000C

    4 5 2 - 3+1 2   ● ● ●   LP-FX06P31-000C

    4 5 2 - 3+1 2   ● ● ●   LP-FX06P32-000C

    4 5 2 - 3+1 2   ● ● ●   LP-FX06P33-000C

  • 8/15/2019 CD-JCI-GENCAT-2007

    12/207

     C O N T R O L S

    Electronic Control DevicesProgrammable Digital ControllerFacility Explorer

    FX07 Field Controller – 24VAC Power Supply

    3+1 = 3 Interlocked Relays + 1 Free Relay

    Features• Freely programmable or congurable using FX Tools• Standalone or network installation (via optional Communication Card for BACnet® or N2Open

    or LonWorks® networks)• Status report via SMS (via optional RS232C communication card using a GSM modem)• Digital input transition counter and pulse width modulation (PWM) output• Optional integral 2-line LCD display with graphical icons – freely programmable• Choice of optional user interfaces, integral and remote• DIN Rail mounting

    • Multilanguage database for user display (up to 5 languages per application)

    Communication CardsFX07 N2Open Communication Card LP-NET071-000CFX07 LonWorks® Communication Card LP-NET072-010CFX07 RS232C Communication Card LP-NET073-000CFX07 BACnet® Communication Card LP-NET074-000C

    Mounting/Connection AccessoriesLink cable for the connection of the FX07/FX14/FX15/FX16to the Panel Mount MUI display – 3 m (9.8 ft) LP-KIT007-000C

    I/O Details Accessories Included Ordering Code

       A   n   a   l   o   g   u   e   I   n   p   u   t

       D   i   g   i   t   a   l   I   n   p   u   t

       A   n   a   l   o   g   u   e    O   u   t   p   u   t

       D   i   g   i   t   a   l    O   u   t   p   u   t

       (   R   e   l   a   y   s   )

       D   i   g   i   t   a   l    O   u   t   p   u   t

       (   T   r   i   a   c   s   )

       I   n   t   e   g   r   a   t   e   d   D   i   s   p   l   a   y

       N   2    O   p   e   n

        C   o   m   m   u   n   i   c   a   t   i   o   n    C   a   r   d

         L     O     N     W     O     R     K     S

        ® 

        C   o   m   m   u   n   i   c   a   t   i   o   n    C   a   r   d

       R    S   2   3   2    C

        C   o   m   m   u   n   i   c   a   t   i   o   n    C   a   r   d

       B   A    C   n   e   t    ®

        C   o   m   m   u   n   i   c   a   t   i   o   n    C   a   r   d

       R   e   m   o   v   a   b   l   e    C   o   n   n   e   c   t   o   r   s

    4 5 2 6 -   ●   LP-FX07D00-000C

    4 5 2 6 -   ● ●   LP-FX07D01-000C

    4 5 2 6 -   ● ●   LP-FX07D02-000C

    4 5 2 6 -   ● ●   LP-FX07D03-000C

    4 5 2 6 -   ● ●   LP-FX07D04-000C

    4 5 2 6 -   ● ●   LP-FX07D50-000C

    4 5 2 6 -   ● ● ●   LP-FX07D51-000C

    4 5 2 6 -   ● ● ●   LP-FX07D52-000C

    4 5 2 6 -   ● ● ●   LP-FX07D53-000C

    4 5 2 6 -   ● ● ●   LP-FX07D54-000C

    4 5 2 4 2   ●   LP-FX07D20-000C4 5 2 4 2   ● ●   LP-FX07D21-000C

    4 5 2 4 2   ● ●   LP-FX07D22-000C

    4 5 2 4 2   ● ●   LP-FX07D23-000C

    4 5 2 4 2   ● ●   LP-FX07D24-000C

    4 5 2 4 2   ● ●   LP-FX07D70-000C

    4 5 2 4 2   ● ● ●   LP-FX07D71-000C

    4 5 2 4 2   ● ● ●   LP-FX07D72-000C

    4 5 2 4 2   ● ● ●   LP-FX07D73-000C

    4 5 2 4 2   ● ● ●   LP-FX07D74-000C

    4 5 2 3+1 2   ●   LP-FX07D30-000C

    4 5 2 3+1 2   ● ●   LP-FX07D31-000C

    4 5 2 3+1 2   ● ●   LP-FX07D32-000C

    4 5 2 3+1 2   ● ●   LP-FX07D33-000C

    4 5 2 3+1 2   ● ●   LP-FX07D34-000C

    4 5 2 3+1 2   ● ●   LP-FX07D80-000C

    4 5 2 3+1 2   ● ● ●   LP-FX07D81-000C

    4 5 2 3+1 2   ● ● ●   LP-FX07D82-000C

    4 5 2 3+1 2   ● ● ●   LP-FX07D83-000C

    4 5 2 3+1 2   ● ● ●   LP-FX07D84-000C

  • 8/15/2019 CD-JCI-GENCAT-2007

    13/207

     C O N T R O L S

    Electronic Control DevicesProgrammable Digital ControllerFacility Explorer

    FX07 Field Controller – 90-240VAC Power Supply

    3+1 = 3 Interlocked Relays + 1 Free Relay

    Features• Freely programmable or congurable using FX Tools• Standalone or network installation (via optional Communication Card for BACnet® or N2Open

    or LonWorks® networks)• Status report via SMS (via optional RS232C communication card using a GSM modem)• Digital input transition counter and pulse width modulation (PWM) output• Optional integral 2-line LCD display with graphical icons – freely programmable• Choice of optional user interfaces, integral and remote• DIN Rail mounting

    • Multilanguage database for user display (up to 5 languages per application)

    Communication CardsFX07 N2Open Communication Card LP-NET071-000CFX07 LonWorks® Communication Card LP-NET072-010CFX07 RS232C Communication Card LP-NET073-000CFX07 BACnet® Communication Card LP-NET074-000C

    Mounting/Connection AccessoriesLink cable for the connection of the FX07/FX14/FX15/FX16to the Panel Mount MUI display – 3 m (9.8 ft) LP-KIT007-000C

    I/O Details Accessories Included Ordering Code

       A   n   a   l   o   g   u   e   I   n   p   u   t

       D   i   g   i   t   a   l   I   n   p   u   t

       A   n   a   l   o   g   u   e    O   u   t   p   u   t

       D   i   g   i   t   a   l    O   u   t   p   u   t

       (   R   e   l   a   y   s   )

       D   i   g   i   t   a   l    O   u   t   p   u   t

       (   2   3   0   V   A    C   T   r   i   a   c   s   )

       I   n   t   e   g   r   a   t   e   d   D   i   s   p   l   a   y

       N   2    O   p   e   n

        C   o   m   m   u   n   i   c   a   t   i   o   n    C   a   r   d

         L     O     N     W     O     R     K     S

        ® 

        C   o   m   m   u   n   i   c   a   t   i   o   n    C   a   r   d

       R    S   2   3   2    C

        C   o   m   m   u   n   i   c   a   t   i   o   n    C   a   r   d

       B   A    C   n   e   t    ® 

        C   o   m   m   u   n   i   c   a   t   i   o   n    C   a   r   d

       R   e   m   o   v   a   b   l   e    C   o   n   n   e   c   t   o   r   s

    4 5 2 6 -   ●   LP-FX07A00-000C

    4 5 2 6 -   ● ●   LP-FX07A01-000C

    4 5 2 6 -   ● ●   LP-FX07A02-000C

    4 5 2 6 -   ● ●   LP-FX07A03-000C

    4 5 2 6 -   ● ●   LP-FX07A04-000C

    4 5 2 6 -   ● ●   LP-FX07A50-000C

    4 5 2 6 -   ● ● ●   LP-FX07A51-000C

    4 5 2 6 -   ● ● ●   LP-FX07A52-000C

    4 5 2 6 -   ● ● ●   LP-FX07A53-000C

    4 5 2 6 -   ● ● ●   LP-FX07A54-000C

    4 5 2 4 2   ●   LP-FX07A20-000C4 5 2 4 2   ● ●   LP-FX07A21-000C

    4 5 2 4 2   ● ●   LP-FX07A22-000C

    4 5 2 4 2   ● ●   LP-FX07A23-000C

    4 5 2 4 2   ● ●   LP-FX07A24-000C

    4 5 2 4 2   ● ●   LP-FX07A70-000C

    4 5 2 4 2   ● ● ●   LP-FX07A71-000C

    4 5 2 4 2   ● ● ●   LP-FX07A72-000C

    4 5 2 4 2   ● ● ●   LP-FX07A73-000C

    4 5 2 4 2   ● ● ●   LP-FX07A74-000C

    4 5 2 3+1 2   ●   LP-FX07A30-000C

    4 5 2 3+1 2   ● ●   LP-FX07A31-000C

    4 5 2 3+1 2   ● ●   LP-FX07A32-000C

    4 5 2 3+1 2   ● ●   LP-FX07A33-000C

    4 5 2 3+1 2   ● ●   LP-FX07A34-000C

    4 5 2 3+1 2   ● ●   LP-FX07A80-000C

    4 5 2 3+1 2   ● ● ●   LP-FX07A81-000C

    4 5 2 3+1 2   ● ● ●   LP-FX07A82-000C

    4 5 2 3+1 2   ● ● ●   LP-FX07A83-000C

    4 5 2 3+1 2   ● ● ●   LP-FX07A84-000C

  • 8/15/2019 CD-JCI-GENCAT-2007

    14/207

     C O N T R O L S

    Electronic Control DevicesProgrammable Digital ControllerFacility Explorer

    FX14 Field Controller – 24VAC Power Supply

    Features• Freely Programmable or Congurable using FX Tools• Standalone or Network Installation (via optional Communication Card for BACnet® or N2Open

    or LonWorks® communication)• Status report via SMS (via optional RS232C Communication Card in conjunction with a GSM modem)• Digital Input Transition Counter and Pulse Width Modulating output• Optional Integral 2-lines LCD Display with graphical icons• Choice of optional User Interfaces, Integral and Remote• DIN-Rail Mounting

    • Multilanguage Database (up to 5 languages per application)

    Communication ModulesFX14 N2Open Communication Card LP-NET151-010CFX14 BACnet® Communication Card LP-NET164-000CFX14 LonWorks® Communication Card LP-NET142-010CFX14 RS232C Communication Card LP-NET163-000C

    Mounting/Connection AccessoriesLink cable for the connection of the FX07/FX14/FX15/FX16to the Panel Mount MUI display – 3 m (9.8 ft) LP-KIT007-000C

    I/O Details Accessories Included Ordering Code

       A   n   a   l   o   g   u   e   I   n   p   u   t

       D   i   g   i   t   a   l   I   n   p   u   t

       A   n   a   l   o   g   u   e    O   u   t   p   u   t

       D   i   g   i   t   a   l    O   u   t   p   u   t

       (   R   e   l   a   y   s   )

       D   i   g   i   t   a   l    O   u   t   p   u   t

       (   T   r   i   a   c   s   )

       I   n   t   e   g   r   a   t   e   d   D   i   s   p   l   a   y

       N   2    O   p   e   n

        C   o   m   m   u   n   i   c   a   t   i   o   n    C   a   r   d

         L     O     N     W     O     R     K     S

        ® 

        C   o   m   m   u   n   i   c   a   t   i   o   n    C   a   r   d

       R    S   2   3   2    C

        C   o   m   m   u   n   i   c   a   t   i   o   n    C   a   r   d

       B   A    C   n   e   t    ® 

        C   o   m   m   u   n   i   c   a   t   i   o   n    C   a   r   d

       R   e   m   o   v   a   b   l   e    C   o   n   n   e   c   t   o   r   s

    6 12 2 5 4   ●   LP-FX14D10-000C

    6 12 2 5 4   ● ●   LP-FX14D11-000C

    6 12 2 5 4   ● ●   LP-FX14D12-000C

    6 12 2 5 4   ● ●   LP-FX14D13-000C

    6 12 2 5 4   ● ●   LP-FX14D14-000C

    6 12 2 5 4   ● ●   LP-FX14D60-000C

    6 12 2 5 4   ● ● ●   LP-FX14D61-000C

    6 12 2 5 4   ● ● ●   LP-FX14D62-000C

    6 12 2 5 4   ● ● ●   LP-FX14D63-000C

    6 12 2 5 4   ● ● ●   LP-FX14D64-000C

    6 12 2 9 -   ●   LP-FX14D20-000C

    6 12 2 9 -   ● ●   LP-FX14D21-000C

    6 12 2 9 -   ● ●   LP-FX14D22-000C

    6 12 2 9 -   ● ●   LP-FX14D23-000C

    6 12 2 9 -   ● ●   LP-FX14D24-000C

    6 12 2 9 -   ● ●   LP-FX14D70-000C

    6 12 2 9 -   ● ● ●   LP- FX14D71-000C

    6 12 2 9 -   ● ● ●   LP- FX14D72-000C

    6 12 2 9 -   ● ● ●   LP- FX14D73-000C

    6 12 2 9 -   ● ● ●   LP- FX14D74-000C

  • 8/15/2019 CD-JCI-GENCAT-2007

    15/207

     C O N T R O L S

    Electronic Control DevicesProgrammable Digital ControllerFacility Explorer

    FX15 “Classic” Field Controller – 24VAC Power Supply

    Features• Freely programmable or congurable using FX Tools• Standalone or network installation (via optional communication module for N2Open  or LonWorks® networks)• Events management• Extension possibility via I/O modules• Possibility of connecting two optional remote MUI displays• Choice of optional User Interfaces, Integral and Remote• DIN Rail mounting

    • Multilanguage database for user interface (up to 5 languages per application)

    Communication CardsFX15 N2Open Communication Card LP-NET151-010CFX15 LonWorks® Communication Card LP-NET152-010C

    Mounting/Connection AccessoriesLink cable for the connection of the FX07/FX14/FX15/FX16to the Panel Mount MUI display – 3 m (9.8 ft) LP-KIT007-000C

    I/O Details Accessories Included Ordering Code

       A   n   a

       l   o   g   u   e   I   n   p   u   t

       D   i   g   i   t   a   l   I   n   p   u   t

       A   n   a

       l   o   g   u   e    O   u   t   p   u   t

       D   i   g   i   t   a   l    O   u   t   p   u   t

       (   R   e   l   a   y   s   )

       D   i   g   i   t   a   l    O   u   t   p   u   t

       (   T   r   i   a   c   s   )

       I   n   t   e

       g   r   a   t   e   d   D   i   s   p   l   a   y

       N   2    O

       p   e   n

        C   o   m

       m   u   n   i   c   a   t   i   o   n    C   a   r   d

         L     O     N     W     O     R     K     S

        ® 

        C   o   m

       m   u   n   i   c   a   t   i   o   n    C   a   r   d

       R   e   m

       o   v   a   b   l   e    C   o   n   n   e   c   t   o   r   s

    6 8 4 4 5   ●   LP-FX15D10-000C

    6 8 4 4 5   ● ●   LP-FX15D11-000C

    6 8 4 4 5   ● ●   LP-FX15D12-000C

    6 8 4 4 5   ● ●   LP-FX15D60-000C

    6 8 4 4 5   ● ● ●   LP-FX15D61-000C

    6 8 4 4 5   ● ● ●   LP-FX15D62-000C

    6 8 4 9 -   ●   LP-FX15D20-000C

    6 8 4 9 -   ● ●   LP-FX15D21-000C

    6 8 4 9 -   ● ●   LP-FX15D22-000C

    6 8 4 9 -   ● ●   LP-FX15D70-000C

    6 8 4 9 -   ● ● ●   LP- FX15D71-000C

    6 8 4 9 -   ● ● ●   LP- FX15D72-000C

    6 8 4 4 5   ●   LP-FX15X10-000C

    6 8 4 4 5   ● ●   LP-FX15X11-000C

    6 8 4 4 5   ● ●   LP-FX15X12-000C

    6 8 4 9 -   ●   LP-FX15X20-000C6 8 4 9 -   ● ●   LP-FX15X21-000C

    6 8 4 9 -   ● ●   LP-FX15X22-000C

  • 8/15/2019 CD-JCI-GENCAT-2007

    16/207

     C O N T R O L S

    Electronic Control DevicesProgrammable Digital ControllerFacility Explorer

    FX15 “Universal” Field Controller – 24VAC Power Supply

    Features• Freely programmable or congurable using FX Tools• Standalone or network installation (via optional communication module for N2Open  or LonWorks® networks)• Events management• Extension possibility via I/O modules• Possibility of connecting two optional remote MUI displays• Choice of optional User Interfaces, Integral and Remote• DIN Rail mounting

    • Multilanguage database for user interface (up to 5 languages per application)

    Communication CardsFX15 N2Open Communication Card LP-NET151-000CFX15 LonWorks® Communication Card LP-NET152-000C

    Mounting/Connection AccessoriesLink cable for the connection of the FX07/FX14/FX15/FX16to the Panel Mount MUI display – 3 m (9.8 ft) LP-KIT007-000C

    I/O Details Accessories Included Ordering Code

       A   n   a

       l   o   g   u   e   I   n   p   u   t

       D   i   g   i   t   a   l   I   n   p   u   t

       A   n   a

       l   o   g   u   e    O   u   t   p   u   t

       D   i   g   i   t   a   l    O   u   t   p   u   t

       (   R   e   l   a   y   s   )

       D   i   g   i   t   a   l    O   u   t   p   u   t

       (   T   r   i   a   c   s   )

       I   n   t   e

       g   r   a   t   e   d   D   i   s   p   l   a   y

       N   2    O

       p   e   n

        C   o   m

       m   u   n   i   c   a   t   i   o   n    C   a   r   d

         L     O     N     W     O     R     K     S

        ® 

        C   o   m

       m   u   n   i   c   a   t   i   o   n    C   a   r   d

    6 8 4 3 5   LP-FX15D00-000C

    6 8 4 3 5   ●   LP-FX15D01-000C

    6 8 4 3 5   ●   LP-FX15D02-000C

    6 8 4 3 5   ●   LP-FX15D50-000C

    6 8 4 3 5   ● ●   LP-FX15D51-000C

    6 8 4 3 5   ● ●   LP-FX15D52-000C

  • 8/15/2019 CD-JCI-GENCAT-2007

    17/207

     C O N T R O L S

    Electronic Control DevicesProgrammable Digital ControllerFacility Explorer

    FX16 Master Controller – 24VAC Power Supply

    Features• Freely programmable or congurable using FX Tools• Standalone or network installation (via optional communication card for BACnet®,  N2Open or LonWorks® networks)• Direct or modem connection with PC (via optional RS232C communication card)• Embedded Webserver• Built-In E-mail and SMS manager• Trend and event logging• Extension possibility via I/O modules and/or maximum 16 “slave” controllers

    • Possibility of connecting two optional remote MUI Displays• Choice of optional user interfaces, integral and remote• DIN rail mounting• Multilanguage database for user display (up to 5 languages per application)

    Communication CardsFX16 N2Open Communication Card LP-NET161-000CFX16 LonWorks® Communication Card LP-NET152-010CFX16 RS232C Communication Card LP-NET163-000CFX07 BACnet® Communication Card LP-NET164-000C

    Mounting/Connection AccessoriesLink cable for the connection of the FX07/FX14/FX15/FX16

    to the Panel Mount MUI display – 3 m (9.8 ft) LP-KIT007-000C

    I/O Details Accessories Included Ordering Code

       A   n   a   l   o   g   u   e   I   n   p   u   t

       D   i   g   i   t   a   l   I   n   p   u   t

       A   n   a   l   o   g   u   e    O   u   t   p   u   t

       D   i   g   i   t   a   l    O   u   t   p   u   t

       (   R   e   l   a   y   s   )

       D   i   g   i   t   a   l    O   u   t   p   u   t

       (   T   r   i   a

       c   s   )

       I   n   t   e   g   r   a   t   e   d   D   i   s   p   l   a   y

       N   2    O

       p   e   n

        C   o   m

       m   u   n   i   c   a   t   i   o   n    C   a   r   d

         L     O     N     W     O     R     K     S

        ® 

        C   o   m

       m   u   n   i   c   a   t   i   o   n    C   a   r   d

       R    S   2

       3   2    C

        C   o   m

       m   u   n   i   c   a   t   i   o   n    C   a   r   d

       B   A    C

       n   e   t    ®

        C   o   m

       m   u   n   i   c   a   t   i   o   n    C   a   r   d

       R   e   m

       o   v   a   b   l   e    C   o   n   n   e   c   t   o   r   s

    6 8 4 9 -   ● ●   LP-FX16X01-000C

    6 8 4 9 -   ● ●   LP-FX16X02-000C

    6 8 4 9 -   ● ●   LP-FX16X03-000C

    6 8 4 9 -   ● ●   LP-FX16X04-000C

    6 8 4 4 5   ●   LP-FX16X10-000C

    6 8 4 4 5   ● ●   LP-FX16X11-000C

    6 8 4 4 5   ● ●   LP-FX16X12-000C

    6 8 4 4 5   ● ●   LP-FX16X13-000C

    6 8 4 4 5   ● ●   LP-FX16X14-000C

    6 8 4 9 -   ● ●   LP-FX16X50-000C

    6 8 4 9 -   ● ● ●   LP-FX16X51-000C

    6 8 4 9 -   ● ● ●   LP-FX16X52-000C

    6 8 4 9 -   ● ● ●   LP-FX16X53-000C

    6 8 4 9 -   ● ● ●   LP-FX16X54-000C

    6 8 4 4 5   ● ●   LP-FX16X60-000C

    6 8 4 4 5   ● ● ●   LP-FX16X61-000C6 8 4 4 5   ● ● ●   LP-FX16X62-000C

    6 8 4 4 5   ● ● ●   LP-FX16X63-000C

    6 8 4 4 5   ● ● ●   LP-FX16X64-000C

  • 8/15/2019 CD-JCI-GENCAT-2007

    18/207

     C O N T R O L S

    Features• Freely programmable or congurable using FX Tools• Standalone or network installation (via N2Open and LonWorks® communication ports)• Direct or modem connection with PC (via RS232C communication ports)• Embedded Webserver• Built-In E-mail, FAX and SMS manager• Trend and event logging• Extension possibility via I/O modules and/or maximum 8 “slave” controllers• Serial printer port for recording events and trends

    • Integrated graphical display (240x148 pixel) and selection keys• DIN rail and panel door mounting• Multilanguage database for user display (up to 5 languages per application)

    Mounting/Connection AccessoriesMaster Display Panel Mount Kit LP-KIT020-000CMD20 Serial Commissioning Adapter LP-KIT007-015C 

    Electronic Control DevicesProgrammable Digital ControllerFacility Explorer

    MD20 Master Display – 24VAC Power Supply

    I/O Details Accessories Included Ordering Code

       D   i   g   i   t   a   l   I   n   p   u   t

       D   i   g   i   t   a   l    O   u   t   p   u   t

       (   R   e   l   a   y   s   )

        S   e   r   i   a   l   P   r   i   n   t   e   r   P   o   r   t

       N   2    O

       p   e   n

        C   o   m

       m   u   n   i   c   a   t   i   o   n   P   o   r   t

         L     O     N     W     O     R     K     S

        ® 

        C   o   m

       m   u   n   i   c   a   t   i   o   n    C   a   r   d   )

       R    S   2

       3   2

        C   o   m

       m   u   n   i   c   a   t   i   o   n   P   o   r   t

    2 2   ● ●   LP-MD20D00-000C

    2 8   ● ●   LP-MD20D01-000C

    2 8   ● ● ●   LP-MD20D02-000C

    2 8   ● ●   LP-MD20D03-000C

    2 8   ● ● ●   LP-MD20D04-000C

    2 8   ● ● ●   LP-MD20D05-000C

  • 8/15/2019 CD-JCI-GENCAT-2007

    19/207

     C O N T R O L S

    I/O Modules Description Compatibility Ordering Code

       F   X   0   6

       F   X   0   7

       F   X   1   4

       F   X   1   5

       F   X   1   6

       M   D   2   0

    Extension Module   ● ● ●   LP-XT91D00-000C

    Expansion Module: 6 AIs, 2 AOs   ● ● ●   LP-XP91D02-000C

    Expansion Module: 8 DOs (triacs)   ● ● ●   LP-XP91D03-000C

    Expansion Module: 4 DIs, 4 DOs (triacs)   ● ● ●   LP-XP91D04-000C

    Expansion Module: 8 DIs   ● ● ●   LP-XP91D05-000C

    Expansion Module: 4 DOs (relays) 230 VAC   ● ● ●   LP-XP91D06-000C

    Electronic Control DevicesProgrammable Digital ControllerAccessories

    Network Room Sensor ModuleNetwork

    Room Sensor Module  Description Compatibility Ordering Code

       F   X   0   6

       F   X   0   7

       F   X   1   4

       F   X   1   5

       F   X   1   6

       M   D   2   0

    N2 Open Network Room Sensor Module,temperature output only - without LCD Display.

      ● ● ●   LP-NRM001-000C

    N2 Open Network Room Sensor Module, LCD display,temperature output and setpoint dial.

      ● ● ●   LP-NRM002-000C

    N2 Open Network Room Sensor Module, LCD display,temperature output, setpoint dial, °C/°F button.

      ● ● ●   LP-NRM052-000C

    N2 Open Network Room Sensor Module, LCD display,temperature output, setpoint dial, fan speed override.

      ● ● ●   LP-NRM003-000C

    N2 Open Network Room Sensor Module, LCD Display,temperature output, setpoint dial, fan speed override. °C/°F button.

      ● ● ●   LP-NRM053-000C

    Medium User Interface (MUI) Display

    MUI Display Description Compatibility Ordering Code

    FX06 FX07 FX14 FX15 FX16

     

    Medium User Interface v.3, (4 x26 char.) LCD blue/whitebacklit display, local panel mount (non-isolated version).

      ● ● ● ● ●   LP-DIS60P20-0C

    Medium User Interface v.3, (4 x26 char.) LCD blue)/whitebacklit display, remote wall or panel mount (isolated version)

      ● ● ● ● ●   LP-DIS60P21-0C

    Link cable for the connection of FX07/FX14/FX15/FX16to the MUI. (3m)

      ● ● ● ●   LP-KIT007-000C

    Link cable for the connection of FX06to the MUI. (3m)

      ●   LP-KIT007-005C

    Extension and Expansion I/O Modules

  • 8/15/2019 CD-JCI-GENCAT-2007

    20/207

     C O N T R O L S

    Multimedia Description Compatibility Ordering Code

       F   X   0   6

       F   X   0   7

       F   X   1   4

       F   X   1   5

       F   X   1   6

       M   D   2   0

    Modem: GSM 900/1800 FastTrack.   ● ● ● ● ●   LP-KIT090-000C

    GSM modem plug-in antenna.   ● ● ● ● ●   LP-KIT090-001C

    GSM modem magnetic mount antenna - 2.5m (8 ft) cable.   ● ● ● ● ●   LP-KIT090-003C

    GSM modem panel mount antenna - 5m (16 ft) cable.   ● ● ● ● ●   LP-KIT090-004C

    GSM modem power adapter, 230 VAC/12 VDC.Central European wall plug.

      ● ● ● ● ●   LP-KIT090-005C

    Link cable to standard modem - DB9, 1.5m (5 ft).   ● ●   LP-KIT007-001C

    Link cable to GSM modem - DB15, 1.5m (5 ft).   ● ● ● ● ●   LP-KIT007-002C

    Null modem link cable - RS-232, 3m (10 ft).   ● ●   LP-KIT007-013C

    Null modem link cable - RS-232, 15m (49 ft).   ● ●   LP-KIT007-014C

    Multimedia

    FX TOOLS Description Compatibility Ordering Code

       F   X   0   6

       F   X   0   7

       F   X   1   4

       F   X   1   5

       F   X   1   6

       M   D   2   0

    FX Tools Pro CD-Rom (FX Builder, FX Builder Express, FX CommPro N2,FX CommPro LON, FX CommPro BACnet® ). New Users.

      ● ● ● ● ● ●   LP-FXTPRO-0

    FX Tools Pro CD-Rom (FX Builder, FX Builder Express, FX CommPro N2,FX CommPro LON, FX CommPro BACnet® ). Update.

      ● ● ● ● ● ●   LP-FXTPRO-6

    Software

    Electronic Control DevicesProgrammable Digital ControllerAccessories

  • 8/15/2019 CD-JCI-GENCAT-2007

    21/207

     C O N T R O L S

    Electronic Control DevicesProgrammable Digital ControllerSystem 91 N2DX-9100 Controller – 24VAC Power Supply

    Features• Programmable and congurable using GX Tool• Standalone or network installation (N2Open or LonWorks® communication)• Time scheduling, optimal start and trending features• Digital input transition counter and sequencer control module on digital outputs• Optional integral LED display with selection buttons• Choice of user interfaces, integral LED and optional local or remote DX LCD Display• Panel DIN rail or cabinet door mounting• Extension of inputs and outputs via XT/XP modules

    Mounting BasesPanel DIN Rail Mounting Base for DX-9100-8004 and -8454 Controller DX-9100-8997Cabinet Door Mounting Frame for DX-9100-8454 Controller DX-9100-8996FX06 Panel DIN Rail Mounting Base for DX-9121-8004 and 8454 Controller DX-9121-8997Cabinet Door Mounting Frame for DX-9121-8454 Controller DX-9121-8996Panel DIN Rail Mounting Base for DX-9200-8004 and 8454 Controller DX-9200-8997Cabinet Door Mounting Frame for DX-9200-8454 Controller DX-9200-8996

    LCD DisplayDX LCD Display (V3) for DX-9xxx-8454 Controller DT-9100-8104DX LCD Display (V4) for DX-9xxx-8004 Controller DT-9100-8204DX LCD Display Power Adapter DT-9100-8901DX LCD Display Wall Mounting Kit DT-9100-8902

    AccessoriesSecurity Key for LED Display Operation DC-9100-8905DX Controller Download Cable RS232C (9 pin D-connector) DX-9100-8992

    I/O Details Accessories Included Ordering Code

       A   n   a   l   o   g   u   e

       I   n   p   u   t

       D   i   g   i   t   a   l   I   n   p   u   t

       A   n   a   l   o   g   u   e

        O   u   t   p   u   t

       D   i   g   i   t   a   l    O   u   t   p   u   t

       (   R   e   l   a   y   s   )

       D   i   g   i   t   a   l    O   u   t   p   u   t

       (   T   r   i   a   c   s   )

       L   E   D   D   i   s   p   l   a   y

       a   n   d   B   u   t   t   o

       n   s

        S   y   s   t   e   m   9

       1

        C   o   m   m   u   n   i   c   a   t   i   o   n    C   a   r   d

         L     O     N     W     O     R     K     S

        ®    N

       2   E

        C   o   m   m   u   n   i   c   a   t   i   o   n    C   a   r   d

         L     O     N     W     O     R     K     S

        ® 

        C   o   m   m   u   n   i   c   a   t   i   o   n    C   a   r   d

       R    S   2   3   2    C

        C   o   m   m   u   n   i   c   a   t   i   o   n   P   o   r   t

       D   T  -   9   1   0   0

       L    C   D   D   i   s   p   l   a   y

       X   T    C   o   m   m   u   n   i   c   a   t   i   o   n   P   o   r   t

    Digital Controllers

    8 8 8 - 6   ● ●   DX-9100-8004

    8 8 8 - 6   ● ● ● ●   DX-9100-8454

    8 8 8 - 6   ● ●   DX-9121-8004

    8 8 8 - 6   ● ● ● ●   DX-9121-8454

    8 8 8 - 6   ● ●   DX-9200-8004x

    8 8 8 - 6   ● ● ● ●   DX-9200-8454x

    8 8 8 - 6   ● ● ●   DTDX-9100-8004

    Extension and Expansion I/O Modules

    ●   XT-9100-8304

    6 - 2 - -   XP-9102-8304

    - - - - 8   XP-9103-8304

    - 4 - - 4   XP-9104-8304

    - 8 - - -   XP-9105-8304

    - - - 4 -   XP-9106-8304

  • 8/15/2019 CD-JCI-GENCAT-2007

    22/207

     C O N T R O L S

    Electronic Control DevicesProgrammable Digital ControllerSystem 91 N2XTM Extension/Expansion I/O Modules – 24VAC Power Supply

    Features• Programmable and congurable using GX Tool or XTM Congurator• Compatible with Metasys N2 Bus or DX-9100 XT Bus• Modules with analogue inputs or analogue outputs• Modules with digital inputs and digital outputs or two stage relay outputs• Modules with triac outputs• Available with an without manual override• Panel DIN rail mounting• Stick-on labels to indentify names of inputs and outputs and manual overrides

    AccessoriesLabels for Module Front Panel (Pack of 50 sheets with 12 labels each) XST-101-0

    I/O Details Accessories Included Ordering Code

       A   n   a   l   o   g   u   e   I   n   p   u   t

       D   i   g   i   t   a   l   I   n   p   u   t

       A   n   a   l   o   g   u   e    O   u   t   p   u   t

       D   i   g   i   t   a   l    O   u   t   p   u   t

       (   R   e   l   a   y   s   )

       2    S   t   a   g   e   D   i   g   i   t   a   l    O   u   t   p   u   t

       (   R   e   l   a   y   s   )

       D   i   g   i   t   a   l    O   u   t   p   u   t

       (   T   r   i   a   c   s   )

        O   p   t   i   o   n   a   l   l   y

       w   i   t   h   D   i   s   c   o   n   n   e   c   t

       T   e   r   m   l   s

       M   a   n   u   a   l    O   v   e   r   r   i   d   e

        S   y   s   t   e   m   9   1   N   2

        C   o   m   m   u   n   i   c   a   t   i   o   n   P   o   r   t

       X   T    C   o   m   m   u   n   i   c   a   t   i   o   n   P   o   r   t

        C   o   m   p   a   t   i   b   l   e

       w   i   t   h   M   e   t   a   s   y   s

       N   A   E    /   N    C   M

        C   o   m   p   a   t   i   b   l   e

       w   i   t   h   D   X  -   9   1   0   0

        C   o   m   p   a   t   i   b   l   e

       w   i   t   h   F   X   P   l   a   t    f   o   r   m

    Extension Modules

    - - - - - -   ● ●   XTM-105

    - - - - - -   ● ●   XTM-905

    Expansion I/O Modules

    4 - - - - -   ● ● ●   XPA-421-5

    - - 4 - - -   ● ● ● ●   XPA-442-5

    - - 4 - - -   ● ● ●   XPA-462-5

    6 - 2 - - -   ● ● ●   XPA-821-5

    - 8 - - - -   ● ● ●   XPB-821-5

    - 4 - 2 - -   ● ● ● ●   XPM-401-5- 4 - 2 - -   ● ● ●   XPM-421-5

    - 4 - - 1 -   ● ● ●   XPM-402-5

    - 4 - - 1 -   ● ●   XPM-422-5

    - 4 - 2 - -   ● ● ● ●   XPL-401-5

    - 4 - 2 - -   ● ● ●   XPL-421-5

    - 4 - - 1 -   ● ● ●   XPL-402-5

    - 4 - - 1 -   ● ●   XPL-422-5

    - 4 - 2 - -   ● ● ● ●   XPE-401-5

    - 4 - 2 - -   ● ● ●   XPE-421-5

    - 4 - - 1 -   ● ● ●   XPE-402-5

    - 4 - - 1 -   ● ●   XPE-422-5

    - 4 - 4 - -   ● ● ● ●   XPE-404-5

    - 4 - 4 - -   ● ● ●   XPE-424-5

    - - - 4 - -   ● ● ● ●   XPE-444-5

    - - - 4 - -   ● ● ●   XPE-464-5

    - 4 - - - 4   ● ● ● ●   XPT-401-5

    - 4 - - - 4   ● ● ●   XPT-421-5

    - - - - - 8   ● ● ●   XPT-861-5

  • 8/15/2019 CD-JCI-GENCAT-2007

    23/207

     C O N T R O L S

    Electronic Control DevicesProgrammable Digital ControllerSystem 91 N2Terminal Unit Controller TC-910x Series – 24VAC Power Supply

    Features• Fixed congurations for fan coil and chilled ceiling applications with software commissioning tool• Compatible with TM1100 series room modules• Universal controller version for free conguration• Universal controller compatible with RS-1180 room module with temperature display• Multiple modes of operation for energy saving according to occupancy and outside temperature• Relay outputs for fan control, 24VAC triacs or 0-10VDC for heating and cooling valves• Panel DIN Rail or surface mounting• System 91 N2 port for commissioning and integration in building control systems

    AccessoriesUnit Mount NTC 2.25K Temperature Sensor (1.5 m cable) TE-9100-8501Condensation (Dew Point) Sensor (Strap-on) HX-9100-8001

    I/O Details Accessories Included N2 Ordering Code

       W   i   n   d   o   w    C   o   n   t   a   c   t

        O   c   c   u   p   a   n   c   y    S   e   n   s   o   r

        C   o   n   d   e   n   s   a   t   i   o   n    S   e   n   s   o   r

       F   r   e   e   B   i   n   a   r   y   I   n   p   u   t   s   )

       T   e   m   p

       e   r   a   t   u   r   e    S   e   n   s   o   r

       T   M  -   1

       1   0   0

        S   e   r   i   e   s   R   o   o   m   M   o   d   u   l   e

        S   e   t   p   o

       i   n   t   1   2  -   2   8   °    C

        S   e   t   p   o

       i   n   t   +    /  -   3   K

       F   r   e   e   A   n   a   l   o   g   u   e   I   n   p   u   t   s

       H   e   a   t   i   n   g    O   u   t   p   u   t

        C   o   o   l   i   n   g    O   u   t   p   u   t

       F   r   e   e   A   n   a   l   o   g   u   e    O   u   t   p   u   t   s

       0 .   1

       0   V

       D    C

       F   r   e   e   T   r   i   a   c    O   u   t   p   u   t   s

        S   i   n   g   l   e    S   p   e   e   d   F   a   n

       2   3   0   V   A    C

       T   h   r   e   e

        S   p   e   d   F   a   n

       2   3   0   V   A    C

       N   2    S   y   s   t   e   m

       9   1    C   o   m   m   u   n   i   c   a   t   i   o   n

    FCU Controllers

    ● ● - -   ● ● ● - - 10V 10V - -   ● -   ●   TC-9102-0221

    ● ● - -   ● ● -   ● - 10V 10V - -   ● -   ●   TC-9102-0226

    ● ● - - ● ● ● - - DAT DAT - - ● - ●   TC-9102-0441

    ● ● - -   ● ● -   ● - DAT DAT - -   ● -   ●   TC-9102-0446

    ● ● - -   ● ● ● - - PAT PAT - -   ● -   ●   TC-9102-0551

    ● ● - -   ● ● -   ● - PAT PAT - -   ● -   ●   TC-9102-0556

    ● ● - - ● ● ● - - 2St 2St - - ● - ●   TC-9102-0661

    ● ● - -   ● ● -   ● - 2St 2St - -   ● -   ●   TC-9102-0666

    ● ● - -   ● ● ● - - 10V 10V - - -   ● ●   TC-9102-0222

    ● ● - -   ● ● -   ● - 10V 10V - - -   ● ●   TC-9102-0227

    ● ● - - ● ● ● - - DAT DAT - - - ● ●   TC-9102-0442

    ● ● - -   ● ● -   ● - DAT DAT - - -   ● ●   TC-9102-0447

    ● ● - -   ● ● ● - - PAT PAT - - -   ● ●   TC-9102-0552

    ● ●- -

      ● ●-

      ●- PAT PAT - - -

      ● ●  TC-9102-0557

    ● ● - -   ● ● ● - - 2St 2St - - -   ● ●   TC-9102-0662

    ● ● - - ● ● -   ● - 2St 2St - - - ● ●   TC-9102-0667

    Chilled Ceiling Controllers

    -   ● ● -   ● ● ● - - 10V 10V - - - -   ●   TC-9109-0204

    -   ● ● -   ● ● -   ● - 10V 10V - - - -   ●   TC-9109-0209

    - ● ● - ● ● ● - - DAT DAT - - - - ●   TC-9109-0440

    -   ● ● -   ● ● -   ● - DAT DAT - - - -   ●   TC-9109-0445

    -   ● ● -   ● ● ● - - DAT 10V - - - -   ●   TC-9109-0404

    - ● ● - ● ● -   ● - DAT 10V - - - - ●   TC-9109-0409

    -   ● ● -   ● ● ● - - PAT PAT - - - -   ●   TC-9109-0550

    -   ● ● -   ● ● -   ● - PAT PAT - - - -   ●   TC-9109-0555

    - ● ● - ● ● ● - - PAT 10V - - - - ●   TC-9109-0504

    -   ● ● -   ● ● -   ● - PAT 10V - - - -   ●   TC-9109-0509

    Universal Controllers

    - -  ● 2 - - - - 4 - - 3 5 - - ●   TC-9100-0000

    - -  ●

    2 - - - - 4 - - 0 7 - -  ●

      TC-9100-0001Output types:24VAC triac: PAT = Position Adjust Type (incremental actuator ), DAT = Duration Adjust Type (thermal actuator), 2St = Two Stage On/Off

     Analogue output: 10V = 0 to 10VDC

  • 8/15/2019 CD-JCI-GENCAT-2007

    24/207

     C O N T R O L S

    Electronic Control DevicesLonWorks® Digital ControllersTerminal Unit ControllerTCU Series – 24VAC Power Supply – 2 Pipe FCU Applications

    Features• Fixed congurations for fan coil applications with software commissioning tool• Compatible with TM1100 series room modules• Compatible with any LonMark® room command module (including AD-RCM with LCD display)• Multiple modes of operation for energy saving according to occupancy and outside temperature• Relay outputs for fan control, 24VAC triacs or 0-10VDC for heating/cooling valve• Spare triac output available for on/off lighting control• Master/slave controller operation by LonWorks® network variable binding• Panel DIN Rail mounting

    • LonWorks®

     network port for commissioning and integration in building controlsystems

    AccessoriesUnit Mount NTC 2.25K Temperature Sensor (1.5 m cable) TE-9100-8501Conguration and commissioning tool software COMM-PRO-0

    Input Functions Output Functions LON Ordering Code

       W   i   n   d   o   w    C   o   n   t   a   c   t

        O   c   c   u   p   a   n   c   y    S   e   n   s   o   r

       H   e   a   t    /    C   o   o   l    S   e   l   e   c   t

        C   o   n   t   a   c   t

        G   e   n   e   r   a   l    S   t   a   t   u   s

       T   e   m   p   e   r   a   t   u   r   e    S   e   n   s   o   r

       T   M  -   1   1   0   0

        S   e   r   i   e   s   R   o   o   m   M   o   d   u   l   e

        S   e   t   p   o   i   n   t   1   2  -   2   8   °    C

        S   e   t   p   o   i   n   t   +    /  -   3   K

       A   u   x .   T   e   m   p   e   r   a   t   u   r   e

        S   e   n   s   o   r

       H   e   a   t   i   n   g    /    C   o   o   l   i   n   g

        O   u   t   p   u   t

       L   i   g   h   t   i   n   g    O   u   t   p   u   t

       V   a   r   i   a   b   l   e    S   p   e   e   d   F   a   n

        S   i   n   g   l   e    S   p   e   e   d   F   a   n

       2   3   0   V   A    C

       T   h   r   e   e    S   p   e   d   F   a   n

       2   3   0   V   A    C

         L     O     N     W     O     R     K     S

        ®

        C   o   m   m   u   n   i   c   a   t   i   o   n

    FCU Controllers

    ● ● ● -   ● ● ● -   ● 10V   ● -   ● -   ●   AD-TCU1215-1AAA

    ● ● ● -   ● ● -   ● ● 10V   ● -   ● -   ●   AD-TCU1215-1ABA

    ● ● ● - ● ● ● -   ● DAT   ● - ● -   ●   AD-TCU1225-1AAC

    ● ● ● -   ● ● -   ● ● DAT   ● -   ● -   ●   AD-TCU1225-1ABC

    ● ● ● -   ● ● ● -   ● PAT   ● -   ● -   ●   AD-TCU1225-1AAD

    ● ● ● -   ● ● -   ● ● PAT   ● -   ● -   ●   AD-TCU1225-1ABD

    ● ● ●

    -● ● ●

    -  ●

    10V  ●

    -●

    -  ●   AD-TCU1215-1EAA

    ● ● ● -   ● ● -   ● ● 10V   ● -   ● -   ●   AD-TCU1215-1EBA

    ● ● ● -   ● ● ● -   ● DAT   ● -   ● -   ●   AD-TCU1225-1EAC

    ● ● ● -   ● ● -   ● ● DAT   ● -   ● -   ●   AD-TCU1225-1EBC

    ● ● ● - ● ● ● -   ● PAT   ● - ● - ●   AD-TCU1225-1EAD

    ● ● ● -   ● ● -   ● ● PAT   ● -   ● -   ●   AD-TCU1225-1EBD

    ● ● ● -   ● ● ● -   ● 10V   ● - -   ● ●   AD-TCU2215-1AAA

    ● ● ● -   ● ● -   ● ● 10V   ● - - ● ●   AD-TCU2215-1ABA

    ● ● ● -   ● ● ● -   ● DAT   ● - -   ● ●   AD-TCU2225-1AAC

    ● ● ● - ● ● -   ● ● DAT   ● - - ● ●   AD-TCU2225-1ABC

    ● ● ● -   ● ● ● -   ● PAT   ● - -   ● ●   AD-TCU2225-1AAD

    ● ● ● - ● ● -   ● ● PAT   ● - -   ● ●   AD-TCU2225-1ABD

    ● ● ● -   ● ● ● -   ● 10V   ● - -   ● ●   AD-TCU2215-1EAA

    ● ● ● -   ● ● -   ● ● 10V   ● - -   ● ●   AD-TCU2215-1EBA

    ● ● ● - ● ● ● -   ● DAT   ● - -   ● ●   AD-TCU2225-1EAC

    ● ● ● -   ● ● -   ● ● DAT   ● - -   ● ●   AD-TCU2225-1EBC

    ● ● ● -   ● ● ● -   ● PAT   ● - -   ● ●   AD-TCU2225-1EAD

    ● ● ●

    -  ● ●

    -  ● ●

    PAT  ●

    - -  ● ●

      AD-TCU2225-1EBDOutput types:24VAC triac: PAT = Position Adjust Type (incremental actuator) , DAT = Duration Adjust Type (thermal actuator)

     Analogue output: 10V = 0 to 10VDC

  • 8/15/2019 CD-JCI-GENCAT-2007

    25/207

     C O N T R O L S

    Features• Fixed congurations for fan coil applications with software commissioning tool• Compatible with TM1100 series room modules• Compatible with any LonMark® room command module (including AD-RCM with LCD display)• Multiple modes of operation for energy saving according to occupancy and outside temperature• Relay outputs for fan control, 24VAC triacs or 0-10VDC for heating and cooling valves• Spare triac output available for on/off lighting control• Master/slave controller operation by LonWorks® network variable binding• Panel DIN Rail mounting

    • LonWorks®

     network port for commissioning and integration in building control systems

    AccessoriesUnit Mount NTC 2.25K Temperature Sensor (1.5 m cable) TE-9100-8501

    Electronic Control DevicesLonWorks® Digital ControllersTerminal Unit ControllerTCU Series – 24VAC Power Supply – 4 Pipe FCU Applications

    Input Functions Output Functions LON Ordering Code

       W   i   n   d   o   w    C   o   n   t   a   c   t

        O   c   c   u   p   a   n   c   y    S   e   n   s   o   r

        C   o   n   d   e   n   s   a   t   i   o   n    S   e   n   s   o   r

        G   e   n   e   r   a   l    S   t   a   t   u   s

       T   e   m   p   e   r   a   t   u   r   e    S   e   n   s   o   r

       T   M  -   1   1   0   0

        S   e   r   i   e   s   R   o   o   m   M   o   d   u   l   e

        S   e   t   p   o   i   n   t   1   2  -   2   8   °    C

        S   e   t   p   o   i   n   t   +    /  -   3   K

       A   u   x .   T   e   m   p   e   r   a   t   u   r   e

        S   e   n   s   o   r

       H   e   a   t   i   n   g    O   u   t   p   u   t

        C   o   o   l   i   n   g    O   u   t   p   u   t

       L   i   g   h   t   i   n   g    O   u   t   p   u   t

       V   a   r   i   a   b   l   e    S   p   e   e   d   F   a   n

        S   i   n   g   l   e    S   p   e   e   d   F   a   n

       2   3   0   V   A    C

       T   h   r   e   e    S   p   e   d   F   a   n

       2   3   0   V   A    C

         L     O     N     W     O     R     K     S

        ®

        C   o   m   m   u   n   i   c   a   t   i   o   n

    FCU Controllers

    ● ● -   ● ● ● ● -   ● 10V 10V - -   ● -   ●   AD-TCU1205-1BAA

    ● ● -   ● ● ● -   ● ● 10V 10V - -   ● -   ●   AD-TCU1205-1BBA

    ● ● - ● ● ● ● -   ● DAT DAT   ● - ● -   ●   AD-TCU1225-1BAC

    ● ● -   ● ● ● -   ● ● DAT DAT   ● -   ● -   ●   AD-TCU1225-1BBC

    ● ● -   ● ● ● ● -   ● PAT PAT - -   ● -   ●   AD-TCU1225-1BAD

    ● ● -   ● ● ● -   ● ● PAT PAT - -   ● -   ●   AD-TCU1225-1BBD

    ● ● - ● ● ● ● -   ● 2St 2St - - ● -   ●   AD-TCU1225-1BAE

    ● ● -   ● ● ● -   ● ● 2St 2St - -   ● -   ●   AD-TCU1225-1BBE

    ● ● -   ● ● ● ● -   ● DAT 10V   ● -   ● -   ●   AD-TCU1215-1BAG

    ● ● -   ● ● ● -   ● ● DAT 10V   ● -   ● -   ●   AD-TCU1215-1BBG

    ● ● - ● ● ● ● -   ● PAT 10V - - ● - ●   AD-TCU1215-1BAH

    ● ● -   ● ● ● -   ● ● PAT 10V - -   ● -   ●   AD-TCU1215-1BBH

    ● ● -   ● ● ● ● -   ● 2St 10V - -   ● -   ●   AD-TCU1215-1BAJ

    ● ● -   ● ● ● -   ● ● 2St 10V - -   ● -   ●   AD-TCU1215-1BBJ

    ● ● -   ● ● ● ● -   ● OnOff OnOff   ● ● - -   ●   AD-TCU1215-1DAB

    ● ● - ● ● ● -   ● ● OnOff OnOff   ● ● - - ●   AD-TCU1215-1DBB

    ● ● -   ● ● ● ● -   ● DAT DAT   ● ● - -   ●   AD-TCU1215-1DAC

    ● ● - ● ● ● -   ● ● DAT DAT   ● ● - -   ●   AD-TCU1215-1DBC

    ● ● -   ● ● ● ● -   ● 10V 10V - - -   ● ●   AD-TCU2205-1BAA

    ● ● -   ● ● ● -   ● ● 10V 10V - - -   ● ●   AD-TCU2205-1BBA

    ● ● - ● ● ● ● -   ● DAT DAT   ● - -   ● ●   AD-TCU2225-1BAC

    ● ● -   ● ● ● -   ● ● DAT DAT   ● - -   ● ●   AD-TCU2225-1BBC

    ● ● -   ● ● ● ● -   ● PAT PAT - - -   ● ●   AD-TCU2225-1BAD

    ● ● -   ● ● ● -   ● ● PAT PAT - - -   ● ●   AD-TCU2225-1BBD

    ● ● - ● ● ● ● -   ● 2St 2St - - -   ● ●   AD-TCU2225-1BAE

    ● ● -   ● ● ● -   ● ● 2St 2St - - -   ● ●   AD-TCU2225-1BBE

    ● ● -   ● ● ● ● -   ● DAT 10V   ● - -   ● ●   AD-TCU2215-1BAG

    ● ● -   ● ● ● -   ● ● DAT 10V   ● - -   ● ●   AD-TCU2215-1BBG

    ● ● - ● ● ● ● -   ● PAT 10V - - - ● ●   AD-TCU2215-1BAH

    ● ● -   ● ● ● -   ● ● PAT 10V - - -   ● ●   AD-TCU2215-1BBH

    ● ● -   ● ● ● ● -   ● 2St 10V - - -   ● ●   AD-TCU2215-1BAJ

    ● ● -   ● ● ● -   ● ● 2St 10V - - -   ● ●   AD-TCU2215-1BBJOutput types:24VAC triac: PAT = Position Adjust Type (incremental actuator) , DAT = Duration Adjust Type (thermal actuator), 2St = Two Stage On/Off

     Analogue output: 10V = 0 to 10VDC

  • 8/15/2019 CD-JCI-GENCAT-2007

    26/207

     C O N T R O L S

    Electronic Control DevicesLonWorks® Digital ControllersTerminal Unit ControllerTCU Series – 24VAC Power Supply – Chilled Ceiling Applications

    Features• Fixed congurations for chilled ceiling applications with software commissioning tool• Compatible with TM1100 series room modules• Compatible with any LonMark® room command module (including AD-RCM with LCD display)• Multiple modes of operation for energy saving according to occupancy and outside temperature• Relay outputs for fan control, 24VAC triacs or 0-10VDC for heating and cooling valves• Spare triac output available for on/off lighting control• Master/slave controller operation by LonWorks® network variable binding• Panel DIN Rail mounting

    • LonWorks®

     network port for commissioning and integration in building control systems

    AccessoriesUnit Mount NTC 2.25K Temperature Sensor (1.5 m cable) TE-9100-8501Condensation (Dew Point) Sensor (Strap-on) HX-9100-8001Conguration and commissioning tool software COMM-PRO-0

    Input Functions Output Functions LON Ordering Code

       W   i   n   d   o   w    C   o   n   t   a   c   t

        O   c   c   u   p   a   n   c   y    S

       e   n   s   o   r

        C   o   n   d   e   n   s   a   t   i   o   n    S   e   n   s   o   r

        G   e   n   e   r   a   l    S   t   a   t   u   s

       T   e   m   p   e   r   a   t   u   r   e

        S   e   n   s   o   r

       T   M  -   1   1   0   0

        S   e   r   i   e   s   R   o   o   m

       M   o   d   u   l   e

        S   e   t   p   o   i   n   t   1   2  -   2   8   °    C

        S   e   t   p   o   i   n   t   +    /  -

       3   K

       A   u   x .   T   e   m   p   e   r   a   t   u   r   e

        S   e   n   s   o   r

       H   e   a   t   i   n   g    O   u   t   p

       u   t

        C   o   o   l   i   n   g    O   u   t   p

       u   t

       L   i   g   h   t   i   n   g    O   u   t   p   u   t

       V   a   r   i   a   b   l   e    S   p   e   e   d   F   a   n

        S   i   n   g   l   e    S   p   e   e   d

       F   a   n

       2   3   0   V   A    C   o   r   D

       a   m   p   e   r

       T   h   r   e   e    S   p   e   d   F   a   n

       2   3   0   V   A    C

         L     O     N     W     O     R     K     S     ®

        C   o   m   m   u   n   i   c   a   t   i   o   n

    Chilled Ceiling Controllers

    ● ● ● -   ● ● ● -   ● 10V 10V - -   ● -   ●   AD-TCU1205-1CAA

    ● ● ● -   ● ● -   ● ● 10V 10V - -   ● -   ●   AD-TCU1205-1CBA

    ● ● ● - ● ● ● -   ● DAT DAT   ● - ● -   ●   AD-TCU1225-1CAC

    ● ● ● -   ● ● -   ● ● DAT DAT   ● -   ● -   ●   AD-TCU1225-1CBC

    ● ● ● -   ● ● ● -   ● PAT PAT - -   ● -   ●   AD-TCU1225-1CAD

    ● ● ● -   ● ● -   ● ● PAT PAT - -   ● -   ●   AD-TCU1225-1CBD

    ● ● ● -   ● ● ● -   ● DAT 10V   ● -   ● -   ●   AD-TCU1215-1CAG

    ● ● ● -   ● ● -   ● ● DAT 10V   ● -   ● -   ●   AD-TCU1215-1CBG

    ● ● ● - ● ● ● -   ● PAT 10V - - ● - ●   AD-TCU1215-1CAH

    ● ● ● -   ● ● -   ● ● PAT 10V - -   ● -   ●   AD-TCU1215-1CBH

    ● ● ● -   ● ● ● -   ● 2St 10V - -   ● -   ●   AD-TCU1215-1CAJ

    ● ● ● -   ● ● -   ● ● 2St 10V - -   ● -   ●   AD-TCU1215-1CBJOutput types:24VAC triac: PAT = Position Adjust Type (incremental actuator) , DAT = Duration Adjust Type (thermal actuator), 2St = Two Stage On/Off

     Analogue output: 10V = 0 to 10VDC

  • 8/15/2019 CD-JCI-GENCAT-2007

    27/207

     C O N T R O L S

    Features• Fixed congurations for fan coil applications with software commissioning tool• Compatible with TM1100 series room modules• Compatible with any LonMark® room command module (including AD-RCM with LCD display)• Multiple modes of operation for energy saving according to occupancy and outside temperature• Relay outputs for fan control, 24VAC triacs (6VA max.) or 0-10VDC for heating/cooling valve• Spare triac output available for on/off lighting control• Master/slave controller operation by LonWorks® network variable binding• Panel DIN Rail mounting

    • LonWorks®

     network port for commissioning and integration in building control systems

    AccessoriesUnit Mount NTC 2.25K Temperature Sensor (1.5 m cable) TE-9100-8501Conguration and commissioning tool software COMM-PRO-0

    Electronic Control DevicesLonWorks® Digital ControllersTerminal Unit ControllerTCU Series – 230VAC Power Supply – 2 Pipe FCU Applications

    Input Functions Output Functions LON Ordering Code

       W   i   n   d   o   w    C   o   n   t   a   c   t

        O   c   c   u   p   a   n   c   y    S   e   n   s   o   r

       H   e   a   t    /    C   o   o   l    S   e   l   e   c   t

        C   o   n   t   a   c   t

        G   e   n   e   r   a   l    S   t   a   t   u   s

       T   e   m   p   e   r   a   t   u   r   e    S   e   n   s   o   r

       T   M  -   1   1   0   0

        S   e   r   i   e   s   R   o   o   m   M   o   d   u   l   e

        S   e   t   p   o   i   n   t   1   2  -   2   8   °    C

        S   e   t   p   o   i   n   t   +    /  -   3   K

       A   u   x .   T   e   m   p   e   r   a   t   u   r   e

        S   e   n   s   o   r

       H   e   a   t   i   n   g    /    C   o   o   l   i   n   g

        O   u   t   p   u   t

       L   i   g   h   t   i   n   g    O   u   t   p   u   t

       V   a   r   i   a   b   l   e    S   p   e   e   d   F   a   n

        S   i   n   g   l   e    S   p   e   e   d   F   a   n

       2   3   0   V   A    C

       T   h   r   e   e    S   p   e   e   d   F   a   n

       2   3   0   V   A    C

         L     O     N     W     O     R     K     S     ®

        C   o   m   m   u   n   i   c   a   t   i   o   n

    FCU Controllers

    ● ● ● -   ● ● ● -   ● 10V   ● -   ● -   ●   AD-TCU5215-1AAA

    ● ● ● -   ● ● -   ● ● 10V   ● -   ● -   ●   AD-TCU5215-1ABA

    ● ● ● - ● ● ● -   ● DAT   ● - ● -   ●   AD-TCU5225-1AAC

    ● ● ● -   ● ● -   ● ● DAT   ● -   ● -   ●   AD-TCU5225-1ABC

    ● ● ● -   ● ● ● -   ● PAT   ● -   ● -   ●   AD-TCU5225-1AAD

    ● ● ● -   ● ● -   ● ● PAT   ● -   ● -   ●   AD-TCU5225-1ABD

    ● ● ●

    -● ● ●

    -  ●

    10V  ●

    -●

    -  ●   AD-TCU5215-1EAA

    ● ● ● -   ● ● -   ● ● 10V   ● -   ● -   ●   AD-TCU5215-1EBA

    ● ● ● -   ● ● ● -   ● DAT   ● -   ● -   ●   AD-TCU5225-1EAC

    ● ● ● -   ● ● -   ● ● DAT   ● -   ● -   ●   AD-TCU5225-1EBC

    ● ● ● - ● ● ● -   ● PAT   ● - ● - ●   AD-TCU5225-1EAD

    ● ● ● -   ● ● -   ● ● PAT   ● -   ● -   ●   AD-TCU5225-1EBD

    ● ● ● -   ● ● ● -   ● 10V   ● - -   ● ●   AD-TCU6215-1AAA

    ● ● ● -   ● ● -   ● ● 10V   ● - - ● ●   AD-TCU6215-1ABA

    ● ● ● -   ● ● ● -   ● DAT   ● - -   ● ●   AD-TCU6225-1AAC

    ● ● ● - ● ● -   ● ● DAT   ● - - ● ●   AD-TCU6225-1ABC

    ● ● ● -   ● ● ● -   ● PAT   ● - -   ● ●   AD-TCU6225-1AAD

    ● ● ● - ● ● -   ● ● PAT   ● - -   ● ●   AD-TCU6225-1ABD

    ● ● ● -   ● ● ● -   ● 10V   ● - -   ● ●   AD-TCU6215-1EAA

    ● ● ● -   ● ● -   ● ● 10V   ● - -   ● ●   AD-TCU6215-1EBA

    ● ● ● - ● ● ● -   ● DAT   ● - -   ● ●   AD-TCU6225-1EAC

    ● ● ● -   ● ● -   ● ● DAT   ● - -   ● ●   AD-TCU6225-1EBC

    ● ● ● -   ● ● ● -   ● PAT   ● - -   ● ●   AD-TCU6225-1EAD

    ● ● ●

    -  ● ●

    -  ● ●

    PAT  ●

    - -  ● ●

      AD-TCU6225-1EBDOutput types:24VAC triac (6VA max.): PAT = Position Adjust Type (incremental actuator) , DAT = Duration Adjust Type (thermal actuator)

     Analogue output: 10V = 0 to 10VDC

  • 8/15/2019 CD-JCI-GENCAT-2007

    28/207

     C O N T R O L S

    Features• Fixed congurations for fan coil applications with software commissioning tool• Compatible with TM1100 series room modules• Compatible with any LonMark® room command module (including AD-RCM with LCD display)• Multiple modes of operation for energy saving according to occupancy and outside temperature• Relay outputs for fan control, 24VAC triacs (6VA max.) or 0-10VDC for heating and cooling valves• Spare triac output available for on/off lighting control• Master/slave controller operation by LonWorks® network variable binding• Panel DIN Rail mounting

    • LonWorks®

     network port for commissioning and integration in building control systems

    AccessoriesUnit Mount NTC 2.25K Temperature Sensor (1.5 m cable) TE-9100-8501Conguration and commissioning tool software COMM-PRO-0

    Electronic Control DevicesLonWorks® Digital ControllersTerminal Unit ControllerTCU Series – 230VAC Power Supply – 4 Pipe FCU Applications

    Input Functions Output Functions LON Ordering Code

       W

       i   n   d   o   w    C   o   n   t   a   c   t

        O   c   c   u   p   a   n   c   y    S   e   n   s   o   r

        C   o   n   d   e   n   s   a   t   i   o   n    S   e   n   s   o   r

        G   e   n   e   r   a   l    S   t   a   t   u   s

       T   e

       m   p   e   r   a   t   u   r   e    S   e   n   s   o   r

       T   M  -   1   1   0   0

        S   e   r   i   e   s   R   o   o   m   M   o   d   u   l   e

        S   e   t   p   o   i   n   t   1   2  -   2   8   °    C

        S   e   t   p   o   i   n   t   +    /  -   3   K

       A   u   x .   T   e   m   p   e   r   a   t   u   r   e

        S   e   n   s   o   r

       H   e   a   t   i   n   g    O   u   t   p   u   t

        C   o   o   l   i   n   g    O   u   t   p   u   t

       L   i   g   h   t   i   n   g    O   u   t   p   u   t

       V   a   r   i   a   b   l   e    S   p   e   e   d   F   a   n

        S   i   n   g   l   e    S   p   e   e   d   F   a   n

       2   3   0   V   A    C

       T   h   r   e   e    S   p   e   e   d   F   a   n

       2   3   0   V   A    C

         L     O     N     W     O     R     K     S

        ®