8
Postings may contain unverified user-created content and change frequently. The content is provided as-is and is not warrantied by Cisco. 1 2960 switch configuration issues Tom.Church 2 posts since Feb 26, 2007 We have multiple 2960 in the field and are having issue holding the Vlan1 ip address. Seems that after a period of time if the switch gets rebooted 1 or 2 things happen. The switch loses it's entire config or the ip address that is assigned to the vlan1 interfaces disappears. All of the ones in the field have the same configuration. Has anyone heard about this? The IOS code is: c2960-lanbasek9-mz.122-25.FX.bin Kevin Dorrell 3,988 posts since Jun 7, 2001 1. Re: 2960 switch configuration issues Nov 27, 2007 7:11 AM I have not heard of such a problem. I presume you do save your configurations (copy run start) each time you do any changes? Or do you perhaps configure from a TFTP server? Do you have service config anywhere in your configuration? What is in your config register? Could you do a show version please? Kevin Dorrell Luxembourg Tom.Church 2 posts since

Catalyst c2960

Embed Size (px)

Citation preview

Postings may contain unverified user-created content and change frequently. The content is provided as-is andis not warrantied by Cisco.

1

2960 switch configuration issues

Tom.Church 2 posts since

Feb 26, 2007

We have multiple 2960 in the field and are having issue holding the Vlan1 ip address.Seems that after a period of time if the switch gets rebooted 1 or 2 things happen. Theswitch loses it's entire config or the ip address that is assigned to the vlan1 interfacesdisappears. All of the ones in the field have the same configuration. Has anyone heard aboutthis? The IOS code is:

c2960-lanbasek9-mz.122-25.FX.bin

Kevin Dorrell 3,988 posts sinceJun 7, 2001 1. Re: 2960 switch configuration issues Nov 27, 2007 7:11 AM

I have not heard of such a problem. I presume you do save your configurations (copy runstart) each time you do any changes?

Or do you perhaps configure from a TFTP server? Do you have service config anywherein your configuration?

What is in your config register? Could you do a show version please?

Kevin Dorrell

Luxembourg

Tom.Church 2 posts since

2960 switch configuration issues

Postings may contain unverified user-created content and change frequently. The content is provided as-is andis not warrantied by Cisco.

2

Feb 26, 2007 2. Re: 2960 switch configuration issues Nov 27, 2007 7:22 AM

Please note the confreg 0xF

Cisco IOS Software, C2960 Software (C2960-LANBASEK9-M), Version 12.2(25)FX, RELE

ASE SOFTWARE (fc1)

Copyright (c) 1986-2005 by Cisco Systems, Inc.

Compiled Wed 12-Oct-05 23:14 by yenanh

ROM: Bootstrap program is C2960 boot loader

BOOTLDR: C2960 Boot Loader (C2960-HBOOT-M) Version 12.2(25r)SEE1, RELEASESOFTWA

RE (fc1)

2960_68171 uptime is 42 minutes

System returned to ROM by power-on

System image file is "flash:c2960-lanbasek9-mz.122-25.FX.bin"

This product contains cryptographic features and is subject to United

States and local country laws governing import, export, transfer and

use. Delivery of Cisco cryptographic products does not imply

third-party authority to import, export, distribute or use encryption.

Importers, exporters, distributors and users are responsible for

compliance with U.S. and local country laws. By using this product you

2960 switch configuration issues

Postings may contain unverified user-created content and change frequently. The content is provided as-is andis not warrantied by Cisco.

3

agree to comply with applicable laws and regulations. If you are unable

to comply with U.S. and A summary of U.S. laws governing Cisco cryptographic productsmay be found at:

http://www.cisco.com/wwl/export/crypto/tool/stqrg.html

If you require further assistance please contact us by sending email to

[email protected].

cisco WS-C2960-24TT-L (PowerPC405) processor (revision B0) with 61440K/4088K byt

es of memory.

Processor board ID FOC1108Z5D8

Last reset from power-on

1 Virtual Ethernet interface

24 FastEthernet interfaces

2 Gigabit Ethernet interfaces

The password-recovery mechanism is enabled.

64K bytes of flash-simulated non-volatile configuration memory.

Base ethernet MAC Address : 00:1B:53:36:0E:00

Motherboard assembly number : 73-10390-03

Power supply part number : 341-0097-02

Motherboard serial number : FOC11072R9Z

Power supply serial number : DCA11038B6F

2960 switch configuration issues

Postings may contain unverified user-created content and change frequently. The content is provided as-is andis not warrantied by Cisco.

4

Model revision number : B0

Motherboard revision number : C0

local laws, return this product immediately.

64K bytes of flash-simulated non-volatile configuration memory.

Base ethernet MAC Address : 00:1B:53:36:0E:00

Motherboard assembly number : 73-10390-03

Power supply part number : 341-0097-02

Motherboard serial number : FOC11072R9Z

Power supply serial number : DCA11038B6F

Model revision number : B0

Motherboard revision number : C0

Model number : WS-C2960-24TT-L

System serial number : FOC1108Z5D8

Top Assembly Part Number : 800-27221-02

Top Assembly Revision Number : C0

Version ID : V02

CLEI Code Number : COM3L00BRA

Hardware Board Revision Number : 0x01

Switch Ports Model SW Version SW Image

------ ----- ----- ---------- ----------

2960 switch configuration issues

Postings may contain unverified user-created content and change frequently. The content is provided as-is andis not warrantied by Cisco.

5

* 1 26 WS-C2960-24TT-L 12.2(25)FX C2960-LANBASEK9-M

Configuration register is 0xF

rick.savoy 4 posts sinceMar 30, 2007 3. Re: 2960 switch configuration issues Nov 27, 2007 8:29 AM

Hi Tom, I have a similar scenario. I have 2950's and 2960's that either lose theirconfigurations or simply stop responding to a ping although they continue to function as aswitch when that happens. Keep in mind the config could also be erased by holding in themode button for too long. I have not seen any remedy for a few months now on this forum asto why they stop responding. A Cisco case may have to be opened to get the right attention,unless someone can reply to this thread?

glen.grant 4,956 posts sinceDec 19, 2001 4. Re: 2960 switch configuration issues Nov 27, 2007 9:14 AM

We have not seen this problem and we have a lot of 2950's but it rings a bell and I think itwas a code issue if the code is really old. We are running 12.1.22ea10 and have been forsome time and have not seen an issue , my reccomendation would be to upgrade the codeto the latest release. Have never seen a box lose the config unless you have unstable powerwhere it goes down , starts come back and then quickly goes down again , we have seen arouter or 2 where it loses the config in nvram.

[email protected] 3 posts sinceJul 1, 2004 5. Re: 2960 switch configuration issues May 14, 2008 6:46 AM

Hi Tom,

I have an almost identical issue in that I am losing all configuration and going back to theinitial config dialogue.

2960 switch configuration issues

Postings may contain unverified user-created content and change frequently. The content is provided as-is andis not warrantied by Cisco.

6

Cisco IOS Software, C2960 Software (C2960-LANBASE-M), Version 12.2(35)SE5,RELEASE SOFTWARE (fc1)

Copyright (c) 1986-2007 by Cisco Systems, Inc.

Compiled Thu 19-Jul-07 20:06 by nachen

Image text-base: 0x00003000, data-base: 0x00D40000

ROM: Bootstrap program is C2960 boot loader

BOOTLDR: C2960 Boot Loader (C2960-HBOOT-M) Version 12.2(25r)SEE1, RELEASESOFTWARE (fc1)

HOSTNAME uptime is 1 day, 54 minutes

System returned to ROM by power-on

System image file is "flash:c2960-lanbase-mz.122-35.SE5/c2960-lanbase-mz.122-35.SE5.bin"

cisco WS-C2960-24TC-L (PowerPC405) processor (revision E0) with 61440K/4088K bytesof memory.

Processor board ID FOC1144Z25R

Last reset from power-on

2 Virtual Ethernet interfaces

24 FastEthernet interfaces

2 Gigabit Ethernet interfaces

The password-recovery mechanism is enabled.

2960 switch configuration issues

Postings may contain unverified user-created content and change frequently. The content is provided as-is andis not warrantied by Cisco.

7

64K bytes of flash-simulated non-volatile configuration memory.

Base ethernet MAC Address : 00:1E:49:75:B0:00

Motherboard assembly number : 73-9832-07

Power supply part number : 341-0097-02

Motherboard serial number : FOC1143505H

Power supply serial number : AZS114103QF

Model revision number : E0

Motherboard revision number : A0

Model number : WS-C2960-24TC-L

System serial number : FOC1144Z25R

Top Assembly Part Number : 800-26671-03

Top Assembly Revision Number : B0

Version ID : V03

CLEI Code Number : COM3K00BRB

Hardware Board Revision Number : 0x01

Switch Ports Model SW Version SW Image

------ ----- ----- ---------- ----------

* 1 26 WS-C2960-24TC-L 12.2(35)SE5 C2960-LANBASE-M

2960 switch configuration issues

Postings may contain unverified user-created content and change frequently. The content is provided as-is andis not warrantied by Cisco.

8

Configuration register is 0xF