120
CATALOGUE REFRIGERATION | HEATING | AIR-CONDITIONING SPEED CONTROLS | SECURITY SYSTEMS LAE | FANTINI COSMI | WEISS INSTRUMENTS | NHD | GO-LINK

CATALOGUE - Sentien Electronicssentien-electronics.com.au/catalogues/SENTIEN_CATALOGUE.pdf · for a better protection between bezel and metal panel. TECHNICAL DATA CONTROL RANGE -50÷120°C

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: CATALOGUE - Sentien Electronicssentien-electronics.com.au/catalogues/SENTIEN_CATALOGUE.pdf · for a better protection between bezel and metal panel. TECHNICAL DATA CONTROL RANGE -50÷120°C

Let us put you in Control

CATALOGUEREFRIGERATION | HEATING | AIR-CONDITIONING

SPEED CONTROLS | SECURITY SYSTEMS

LAE | FANTINI COSMI | WEISS INSTRUMENTS | NHD | GO-LINK

Page 2: CATALOGUE - Sentien Electronicssentien-electronics.com.au/catalogues/SENTIEN_CATALOGUE.pdf · for a better protection between bezel and metal panel. TECHNICAL DATA CONTROL RANGE -50÷120°C

2

Page 3: CATALOGUE - Sentien Electronicssentien-electronics.com.au/catalogues/SENTIEN_CATALOGUE.pdf · for a better protection between bezel and metal panel. TECHNICAL DATA CONTROL RANGE -50÷120°C

3

Sentien Electronics Pty Ltd was established in 1993.

Sentien Electronics is a distributor for Refrigeration, Heating

and Air-Conditioning controls. The company’s focus has always

been to provide quality products at competitive prices which

meet our customers needs, with an emphasis on reliability

and customer service.

Sentien Electronics prides itself on customer service, with our

knowledgeable and dedicated staff prepared to go the extra

mile to ensure customer satisfaction. It is with this philosophy

and dedication to service which has ensured that Sentien

Electronics has continued to grow and create a trusted name

among its customers and the industry in which it serves.

Throughout the years Sentien Electronics has formed valuable

partnerships with our suppliers which is the key to our success.

Our products are sourced globally from companies which share

the same dedication and philosophy that we do.

Companies such as LAE Electronic, which have been

manufacturing for over 40 years and supply customers such

as Williams Refrigeration, Foster Refrigeration, ATLAS COPCO ,

Criosbanc Carrier and LEC Refrigeration.

We supply Panel Mount, Wall Mount, Din Rail Mounted thermostats

for Normal, Medium and Low Temperature applications. They also

supply a range of Humidity, Pressure and Rack controls, as well

as a range of software for both on-site and remote monitoring that

can be either hard wired or wirelessly networked.

Fantini Cosmi is a European leader for Temperature, Pressure,

Level & Flow Controls in the Heating sector and has been

manufacturing since 1938.

I.C.M. – A USA supplier of Timers, De-Ice Controls, Phase

failure & phase sequence controls, Digital room thermostats.

WEISS Instruments – A USA supplier which has been

manufacturing Temperature & Pressure gauges since 1899.

NHD – A Taiwanese manufacturer of Magnetic Motor Controls,

Contactors, Overloads, enclosures, Soft starters, SCR Power

controllers, with ISO9002, UL, SA, CE Approvals.

We also have access to a wide range of products such as

Differential Air Pressure switches, Axial Cross flow and External

Rotor fans, Centrifugal, forward & backward curved fans, Blower

fans, Electronic fans, power supplies, speed controls, dimmers,

manual reset thermostats, flow switches, Refrigeration, water and

oil solenoid valves. Current sensing switches, pressure transducer,

data loggers, hand-held thermometers, humidity, anemometers,

thermocouples, heating elements for Bain Maries & Hot food bars.

Indicator lamps, rocker, toggle, rotary switches, T8 LEDs in various

sizes, fixed LED strips, flexible LED strips, RGB LEDs.

Our aim is to provide a one stop shop with various products

complimenting the LAE range of digital controls. If you are

interested in a product or products not listed above, feel free

to contact us with your requirements, and we will contact our

sources around the world in an endeavour to provide you with

the optimal solution for your needs.

We look forward to hearing from you in the future.

COMPANY OVERVIEW

SENTIEN ELECTRONICS

Page 4: CATALOGUE - Sentien Electronicssentien-electronics.com.au/catalogues/SENTIEN_CATALOGUE.pdf · for a better protection between bezel and metal panel. TECHNICAL DATA CONTROL RANGE -50÷120°C

4

Page 5: CATALOGUE - Sentien Electronicssentien-electronics.com.au/catalogues/SENTIEN_CATALOGUE.pdf · for a better protection between bezel and metal panel. TECHNICAL DATA CONTROL RANGE -50÷120°C

5

PAGE INDEX

PRODUCT INDEX

CONTENT PAGES

FANS 24 – 28

VOLTAGE STABILISERS 53

THERMOCOUPLE & RTD PROBES 93

CONTACTORS 16 – 22

CIRCUIT BREAKERS 13 – 15

INDICATOR LIGHTS 44 – 49

TEMPERATURE CONTROLLERS 86 – 88

REFRIGERATION SOLENOID VALVES 115 – 118

DATA LOGGERS 23

POWER SUPPLIES 50 – 52

TERMINALS 89 – 92

METERS 34 – 41

SWITCHES 64 – 85

TEMPERATURE TRANSMITTERS 112

ACTUATORS 12

LAE ELECTRONICS 06 – 11

PHASE MONITORS 42 – 43

VALVES 113 – 114

HEATING ELEMENTS 33

RELAYS 55 – 63

THERMOSTATS 101 – 111

FAN SPEED CONTROLS 29 – 32

SCR POWER CONTROLLERS 54

TIMERS 94 – 100

Page 6: CATALOGUE - Sentien Electronicssentien-electronics.com.au/catalogues/SENTIEN_CATALOGUE.pdf · for a better protection between bezel and metal panel. TECHNICAL DATA CONTROL RANGE -50÷120°C

6

CONTROLLERS

LAE ELECTRONIC

ATI-5 UNIVERSAL DEFROST CONTROLLER – FOR HIGH TEMPERATURE

AT2-5 UNIVERSAL DEFROST CONTROLLER – FOR HIGH AND LOW TEMPERATURE

ATI-5

AT2-5

SPECIFICATIONS

FUNCTIONS AS1E-G BS2E-BG BS6E-AL

INPUTS

THERMOSTAT √ √ √

EVAPORATOR √ √

DOOR SWITCH √ √

OUTPUTS

THERMOSTAT 16(4)A √ √

THERMOSTAT 16(8)A √

AUXILIARY 7(2)A √ √

POWER SUPPLY 230VAC √ √ √

SERIAL PORTTTL √

RS485 √

KEYPADGENERIC √ √

WITH LIGHT BUTTON √

SPECIFICATIONS

FUNCTIONS BS4E-G BS4E-BG BS4E-AL

INPUTS

THERMOSTAT √ √ √

EVAPORATOR √ √ √

DOOR SWITCH √ √ √

OUTPUTS

THERMOSTAT √ √ √

EVAPORATOR FANS √ √ √

AUXILIARY √ √ √

POWER SUPPLY 230VAC √ √ √

SERIAL PORT SERIAL PORT TTL √ √

KEYPADGENERIC √ √

WITH LIGHT BUTTON √

APPLICATIONFreestanding upright cabinets and counters, cold stores, plug-in display cases,

control panels, heated cabinets.

Models with removable screw terminal blocks are available. In this case, the letter

“S” of code changes in “Q”, ex. AT1-5BQ2E-BG. All models come with an alarm buzzer.

Versions with 110V power supply are available. On request, the AT1-5 is also available

with gasket for a better protection between bezel and metal panel.

APPLICATIONHigh or Low Temperature upright cabinets and counters, cold stores, plug-in display cases,

control panels, heated cabinets.

Models with removable screw terminal blocks are available. In this case, the letter “S” of

code changes in “Q”, ex. AT2-5BQ4E-AL. All models come with an alarm buzzer. Versions

with 110V power supply are available. On request, the AT2-5 is also available with gasket

for a better protection between bezel and metal panel.

TECHNICAL DATACONTROL RANGE -50÷120°C , -55÷240°F RESOLUTION 0.1 / 1 °C; °F

ACCURACY NTC10K: <±0.3°C (-40.0÷70.0°C) PTC1000: <±0.5°C (-50÷120°C)

POWER SUPPLY 230V~ ±10% 50÷60Hz 3W FRONT PROTECTION IP55

PANEL CUT-OUT 71x 29 mm

SENSOR TYPE selectable NTC10K standard mod.

SN4K20P1/P2 or PTC1000 standard mod. ST1K20P1/P2

TECHNICAL DATACONTROL RANGE -50÷120°C , -55÷240°F RESOLUTION 0.1 / 1 °C; °F

ACCURACY NTC10K: <±0.3°C (-40.0÷70.0°C) PTC1000: <±0.5°C (-50÷120°C)

POWER SUPPLY 230V~ ±10% 50÷60Hz 3W FRONT PROTECTION IP55

PANEL CUT-OUT 71x 29 mm

SENSOR TYPE selectable NTC10K standard mod. SN4K20P1/P2

or PTC1000 standard mod. ST1K20P1/P2

• Selectable Refrigerating or Heating control • Runs on mains power supply

• Direct compressor control through high power 16(4)A, 16(5)A or 16(8)A relay

• Selectable NTC10K or PTC probe input • Integrated defrost functions

• Auxiliary output configurable in four different operation modes • On/Off button

• Absolute or relative temperature alarms • Door open alarm

• Automatic condenser maintenance warning • Connection to LAE supervisory systems

• Optional light control button • Quick programming through ZOT-AT1 key

• Selectable Refrigerating or Heating control • Runs on mains power supply

• Direct compressor control through high power 16(5)A • Excellent evaporator fan control

• Selectable NTC10K or PTC input • Integrated defrost functions

• Auxiliary output configurable in six different operation modes • On/Off button

• Absolute or relative temperature alarms • Door open alarm

• Automatic condenser maintenance warning • Connection to LAE supervisory systems

• Optional light control button • Quick programming through ZOT-AT2 key

• Electrical, off cycle or hot gas defrost

16(8)A

T1ComT2

doorswitch

7(2)AAUX

door

230Vac

TTL

16(5)A

TTL

T1ComT2

DoorSwitch

7(2)A 7(2)AAUX

230Vac

Page 7: CATALOGUE - Sentien Electronicssentien-electronics.com.au/catalogues/SENTIEN_CATALOGUE.pdf · for a better protection between bezel and metal panel. TECHNICAL DATA CONTROL RANGE -50÷120°C

7

LTR-5 SINGLE OUTPUT ON/OFF OR PID THERMOSTAT OR HUMIDISTAT

LT12 WIDE RANGE THERMOMETER OR HYGROMETER

CONTROLLERS

LAE ELECTRONIC

LT12

LTR-5

SPECIFICATIONS

FUNCTIONS CT D/I/E CP D/I/E CJ D/I/E CK D/I/E CA D/I/E

INPUT TYPE PTC* Pt100 TC "J" TC "K" 0 ÷ 1V

RANGE -50 ÷ 150ºC -100 ÷ 600ºC -50 ÷ 700ºC -50 ÷ 900ºC 0 ÷ 100% rH

ACCURACY S1**=±0.2°C; S2**=±1°C ±3°C ±0.1%

RESOLUTION S1**=0.1°C; S2**=1°C 1ºC 0.1%

SUPPLY ..D=12Vac/dc; 2W /..I=24Vac/dc; 3W /..E=230Vac ±10%; 50/60 Hz; 2W

PROTECTION IP54

PANEL CUT-OUT 71 x 29 mm

SPECIFICATIONS

FUNCTIONS LTR-5T LTR-5C LTR-5A

INPUT TYPE PTC NTC10K 0÷1V

RANGE-50÷150°C

-60÷300°F

-40÷125°C

-40÷260°F0÷99.9% r.H.

ACCURACY ±0.3°C(a); ±1.0°C(c) ±0.3°C(b); ±1°C(c) ±0.7% r.H.

RESOLUTION 0.1/1°C; °F 0.1/1 % r.H.

FRONT PROTECTION IP55

PANEL CUT-OUT 71 x 29 mm

LTR-5 T E R S -B

1 2 3 4 5

POS FUNCTION DESCRIPTION

1 INPUT T*= PTC; C**= NTC10K; A= 0÷1V

2 CONNECTORS S= screw terminals; Q= male + female terminals

3 OUTPUT TYPE R = relay; F = SSR drive

4 SUPPLY D =12Vac/dc; E =230Vac; U =115Vac, 2W

5 SERIAL COMM. - = no serial port; -A = TTL; -B = RS485

APPLICATIONTEMPERATURE accurate measurements in cold stores, refrigerating cabinets and tables,

greenhouses, seasoning cells, high temperature ovens or furnaces.

HUMIDITY accurate measurements in greenhouses, seasoning cells, air-conditioned rooms.

* Standard PTC probe is ST1K20P1

**Scale: S1 = -19.9÷99.9°C; S2 = remaining

Models with °F scale are also available.

APPLICATIONTEMPERATURE Control of small cold stores, refrigerated cabinets and tables,

heating systems, heated cupboards, bainsmarie,ovens, laboratory equipment.

HUMIDITY Control of greenhouses, seasoning cells, cold rooms, air-conditioned rooms.

HOW TO ORDER EXAMPLES

LTR-5CSRE-A (NTC10K input, 1 relay, screw terminals, 230Vac supply, TTL port)

LTR-5ASRU (0÷1V input, 1 relay, screw terminals, 115Vac supply, no serial port)

On request, the LTR-5 is also available with gasket for a better protection

between bezel and pane.

• Panel display unit with range between –100 and +900°

• It’s available in the version with °C or °F

• 0.1° or 1° resolution Input for PTC / Pt100 / TC / 0 ÷ 1V

• Runs on mains power supply.

• Runs on mains power supply

• PID with autotuning or ON/OFF control

• Output on relay (16A) or SSR piloting

• Input for PTC, NTC10K or 0÷1V 0.1 / 1°C or 1°F resolution

• Refrigerating (dehumidifying) or heating (humidifying) control mode selection

• Stand-by button on the front

• Load start limitation and safety function in the event of breakage of the sensor

• Quick setup through ZOT-LTR device

• Connection to LAE supervisory systems TAB.

OUT116(4)A

RS485

230V~

Page 8: CATALOGUE - Sentien Electronicssentien-electronics.com.au/catalogues/SENTIEN_CATALOGUE.pdf · for a better protection between bezel and metal panel. TECHNICAL DATA CONTROL RANGE -50÷120°C

8

LAE ELECTRONIC

CONTROLLERS

AC1-5 TWO CHANNEL UNIVERSAL CONTROLLER, ON/OFF OR PID

AC1-2W UNIVERSAL DEFROST CONTROLLER – FOR HIGH AND LOW TEMPERATURE

AC1-5

AC1-2W

APPLICATIONTemperature: Control of small cold stores, refrigerated cabinets and tables,

heating systems, heated cupboards, bains-marie, ovens, laboratory equipment.

Humidity: Control of greenhouses, seasoning cells, cold rooms, air-conditioned rooms.

HOW TO ORDER

AC1-5TS2RW-A (PTC/NTC10K input, screw terminals, 2 relays,

115÷230Vac supply voltage, TTL port)

AC1-5AS2MD-B (0÷1V input, screw terminals, output 1 on SSR drive,

output 2 on relay, 12Vac/dc supply voltage,RS485 port)

* = in the version with 12Vac/dc power supply, the maximum voltage on the outputs

is 50Vac/dc, in order to ensure safety insulations.

(a) -50÷150°C; (b) remaining range.

APPLICATIONTEMPERATURE control of small cold stores, heating systems, bains-marie, ovens,

laboratory equipment.

HOW TO ORDER

AC1-2WTQ2RE-B (PTC/NTC10K input, detachable screw terminals, 2 relays,

230Vac supply voltage, RS485 port)

AC1-2WAQ2RD-A (0÷1V input, detachable screw terminals, 2 relays,

12Vac/dc supply voltage, TTL port)

• Selectable Refrigerating or Heating control • Runs on mains power supply

• Direct compressor control through high power 16(4)A, 16(5)A or 16(8)A relay

• Selectable NTC10K or PTC probe input • Integrated defrost functions

• Auxiliary output configurable in four different operation modes • On/Off button

• Absolute or relative temperature alarms • Door open alarm

• Automatic condenser maintenance warning • Connection to LAE supervisory systems

• Optional light control button • Quick programming through ZOT-AT1 key

• Wall-mount controller • Runs on mains power supply

• PID with autotuning or ON/OFF control • Outputs on relay or for SSR-piloting

• Input for 0÷1V, PTC/NTC10K • 0.1 / 1°C or 1°F resolution

• Selectable Refrigerating/Heating (Dehumidifying/Humidifying) control

• Absolute or relative temperature alarms ON/OFF button on front

• Load start limitation and safety operation in case of probe failure

• Quick programming through ZOT-AC1 key

• Connection to LAE TAB supervisory systems

12(4)A

RS485

7(2)A

115...230Vac

OUT1 OUT2

data I/O

230V ~

OUT2

RS485

OUT18(3)A8(3)A

AC1-5 T S 1 R W -B

1 2 3 4 5 6

POS FUNCTION DESCRIPTION

1 INPUT A = 0÷1V; I = 0/4÷20mA ; J = TC ‘J’ / ‘K ’; P = Pt100; T = PTC/ NTC10K

2 CONNECTIONS S = built-in screw terminals

3 OUTPUT NO. 1 = one; 2 = two

4 OUTPUT TYPE R = relay; M = O ut1 on SSR, Out2 o n relay

5 SUPPLY D* = 12Vac/dc; W = 115…230V ac 50/60Hz; 3 W

6 SERIAL COMM. Nil = no; -A = TTL; -B = RS485

AC1-2W T Q 1 R E -B

1 2 3 4 5 6

POS FUNCTION DESCRIPTION

1 INPUT A = 0÷1V; T = PT C/ NTC10K

2 CONNECTIONS Q = detachable screw terminals

3 OUTPUT NO. 1 = one; 2 = two

4 OUTPUT TYPE R = relay; F = SSR d rives

5 SUPPLY D = 12Vac/dc; E = 230Vac 50/60 Hz; U= 115Vac 50/60Hz 3 W

6 SERIAL COMM. Nil = no; -A = TTL; -B = RS485

SPECIFICATIONS

FUNCTIONS AC1-5T AC1-5P AC1-5J AC1-5A AC1-5I

INPUT TYPE PTC NTC10K Pt100 TC "J" TC "K" 0 ÷ 1V 0/4÷20mA

RANGE-50÷150ºC

-60÷300ºC

-40÷125ºC

-40÷260ºC-100÷850ºC

-150÷999ºC

-50÷750ºC

-60÷999ºC

-50÷999ºC

-60÷999ºCConfigurable in setup

ACCURACY ±0.3°C ±0.3°C±0.3°C(a);

±1°C(b)±3°C ±3mV ±0.2mA

RESOLUTION 0.1 / 1 °C / 1 °F 1 °C / °F 0.1/1

SPECIFICATIONS

FUNCTIONS AC1-5T AC1-5J

INPUT TYPE PTC NTC10K 0÷1V

-50÷150°C

-60÷300°F

-40÷125°C

-40÷260°FConfigurable in setup

ACCURACY ±0.3°C ±0.3°C ±3mV

RESOLUTION 0.1 / 1 °C / 1 °F 0.1/1

Page 9: CATALOGUE - Sentien Electronicssentien-electronics.com.au/catalogues/SENTIEN_CATALOGUE.pdf · for a better protection between bezel and metal panel. TECHNICAL DATA CONTROL RANGE -50÷120°C

9

LAE ELECTRONIC

AD-32 UNIVERSAL POWERFUL DEFROST CONTROLLER

AD2-28 VERSATILE SPLIT DEFROST CONTROLLER

CONTROLLERS

AD-32

AD2-28

SPECIFICATIONS

FUNCTIONS Q13W-AG S24W-AG S35W-BG

TEMPERATURE

INPUTS

THERMOSTAT √ √ √

EVAPORATOR √ √ √

AUXILIARY √ √

DIGITAL INPUTS VOLTAGE FREE CONTACT √ √ √

DIGITAL INPUTS

VOLTAGE FREE CONTACT √

12 ÷ 24VAC VOLTAGE √

DEFROST SYNCHRONISATION √

OUTPUTS

THERMOSTAT 15(5)A √ √ √

EVAPORATOR FANS √ √ √

DEFROST √ √ √

AUXILIARY 1 √ √

AUXILIARY 2 √

CONNECTIONSSCREW TERMINALS √ √

M/F TERMINALS + FASTONS √

POWER SUPPLY 230VAC √ √ √

SERIAL PORTSERIAL PORT TTL √ √

SERIAL PORT RS485 √

APPLICATIONPlug-in cabinets, supermarket display cases, cold stores, upright fridges and freezers, refrigerated tables.

All models come with an alarm buzzer. On request, the AD-32 is also available with 7…30Vdc power supply.

APPLICATIONUpright refrigerators, plug-in and supermarket display cases, cold stores, control panels.

All models come with an alarm buzzer. Versions with power supply 12Vac are also available.

TECHNICAL DATACONTROL RANGE -50÷120°C , -55÷240°F RESOLUTION 0.1 / 1 °C; °F

ACCURACY NTC10K: <±0.3°C (-40.0÷70.0°C) PTC1000: <±0.5°C (-50÷120°C)

POWER SUPPLY 115÷230V~ ±10% 50÷60Hz 3W FRONT PROTECTION IP55

PANEL CUT-OUT 163 x 31.5 mm

SENSOR TYPE selectable NTC10K standard mod. SN4K20P1/P2/P3

or PTC1000 standard mod. ST1K20P1/P2/P3

TECHNICAL DATACONTROL RANGE -50÷120°C , -55÷240°F RESOLUTION 0.1 / 1 °C; °F

ACCURACY NTC10K: <±0.3°C (-40.0÷70.0°C) PTC1000: <±0.5°C (-50÷120°C)

POWER SUPPLY 230VAC ± 10% 50 ÷ 60Hz 3W FRONT PROTECTION IP55

PANEL CUT-OUT 71x 29 mm DIMENSIONS 77x35x20 mm (WxHxD)

SENSOR TYPE selectable NTC10K standard mod. SN4K20P1/P2

or PTC1000 standard mod. ST1K20P1/P2

• Selectable Refrigerating or Heating control • Selectable NTC10K or PTC input

• FLEXICOLD function for energy saving or alternative setpoint

• Timed or optimised defrost control

• Synchronized defrost start and termination with master-slave connection

• Optional control of a second compressor or evaporator

• Excellent evaporator fan control • Connection to LAE supervisory systems

• Absolute or relative temperature alarms and door open alarm

• Temperature and pressure monitoring and condensing unit maintenance

• Light and standby control (On/Off) • Quick programming through ZOT-AD key

• Cyclic defrosts • Synchronized defrost start and termination with master-slave connection

• Selectable NTC10K or PTC input • Light and standby control (On/Off)

• FLEXICOLD function for energy saving or alternative setpoint

• Optional control of a second compressor or evaporator

• Excellent evaporator fan control • Quick programming through ZOT-AD2

• Absolute or relative temperature alarms, door open alarm,

condenser high temperature/pressure alarm • Connection to LAE supervisory systems

• Available display unit: LCD-5S or RU33

115...230Vac RS485

data I/O

DI2 T3

Aux

NL

16(5)AMaximum total

current 30A

16(4)A 7(2)A 7(2)A7(2)A

AUX2AUX1

T2T1

DoorSwitch

Door

Aux Switch12...24Vac

AD2-28C2Q4E-A

DI212÷24Vac

Maximum total current 12A

PowerSupply

L

N

TTLLCD-5S

12(4)A12(8)A 8(3)A 7(2)A

Evaporator fan

Condenser fan

T3T2 T1

remote data I/0

Door

AUX 1

Aux

SPECIFICATIONS

FUNCTIONS B1S3E-A C2Q4E-A C3R5U-B

TEMPERATURE

INPUTS

THERMOSTAT √ √ √

EVAPORATOR √ √ √

AUXILIARY √ √

DOOR SWITCH INPUT VOLTAGE FREE CONTACT √ √ √

D12 AUX.

DIGITAL INPUTS

VOLTAGE FREE CONTACT √

12 ÷ 24VAC VOLTAGE √

DEFROST SYNCHRONISATION √

OUTPUTS

THERMOSTAT 15(5)A √ √ √

EVAPORATOR FANS √ √ √

DEFROST √ √ √

AUXILIARY 1 √ √

AUXILIARY 2 √

CONNECTIONSSCREW TERMINALS √ √

QUICK WITH M/F CONNECTORS √

POWER SUPPLY230VAC √ √

115VAC √

SERIAL PORTTTL √ √

RS485 √

Page 10: CATALOGUE - Sentien Electronicssentien-electronics.com.au/catalogues/SENTIEN_CATALOGUE.pdf · for a better protection between bezel and metal panel. TECHNICAL DATA CONTROL RANGE -50÷120°C

10

LAE ELECTRONIC

CONTROLLERS

HUMIDITY

PRESSURE

HUMIDITY TRANSMITTERSTYPE HT2WAD

SENSOR TYPE Capacitive

OUTPUT SIGNAL 0÷1Vdc

RANGE 0%÷100%r.H

ACCURACY ±5%r.H. (25%÷75%r.H.)

SHEATH Ø14x40mm

PROTECTION IP65 (electronics)

OPERATING TEMPERATURE 0÷75°C (sensor) / 0÷50°C (electronics)

DIMENSIONS OF THE ENCLOSURE 110x53x75mm (electronics)

POWER SUPPLY 12Vdc, 0.2W

HUMIDITY AND TEMPERATURE TRANSMITTERTYPE HT2WSE

SENSOR TYPE Capacitive

OUTPUT SIGNAL RS485

RANGE 0%÷100%r.H / 0÷70°C

ACCURACY ±5%r.H. (25%÷75%r.H.) / ±0.3°C @ 25°C; ±1°C (0÷70°C)

SHEATH Ø14x40mm

PROTECTION IP65 (electronics)

OPERATING TEMPERATURE 0÷75°C (sensor) / 0÷50°C (electronics)

DIMENSIONS OF THE ENCLOSURE 110x53x75mm (electronics)

POWER SUPPLY 12Vdc, 0.2W

PRESSURE TRANSMITTERSTYPE PGT35

SENSOR TYPE Piezoresistive gauge

OUTPUT SIGNAL 4÷20mA

RANGE -0,5÷35,0 bar

ACCURACY max±1%FS (0÷50°C)

SHEATH Ø17x58 mm

CONNECTIONS mPm connector

PRESSURE PORT 7/16”-20UNF male, steel AISI 316L

PROTECTION IP65

AMBIENT TEMPERATURE -40÷100°C

POWER SUPPLY 8÷32Vdc

Page 11: CATALOGUE - Sentien Electronicssentien-electronics.com.au/catalogues/SENTIEN_CATALOGUE.pdf · for a better protection between bezel and metal panel. TECHNICAL DATA CONTROL RANGE -50÷120°C

11

TAB4.2 SOFTWARE

LAE ELECTRONIC

MONI TORI NG, LOGGING AND PROGRAMMING SOFTWARE

• Overall plant monitoring

• Compatible with the wireless communication system

• Storage of temperature, humidity, pressure, alarms

• Display and printing in numerical and graphic form of stored data

• Export of stored data for Excel* or others

• Diagnostics with dynamic graphs of all analog inputs

• Virtual instrument for analysing the system and setting

regulator parameters

• Automatic sending or on demand of SMS to trace alarm status

• Connection to remote PC for tele-servicing via Internet

• Several languages available: English, German, Italian, Spanish, Polish etc

AVAILABLE OPTIONSSupervision of the refrigeration process in supermarkets, convenience stores,

shops, petrol stations, large kitchens, food factories, cruise ships etc.

APPLICATIONS• Computer with Windows XP/Vista* operating system installed

and properly running,minimum processor and memory as required

from Windows* version – USB port – Mouse – CD-ROM drive

• 1024x768 pixel screen resolution, 16-bit colour

• 1GB available on Hard Disk

• RS232 serial port (COM); an additional port is required if a GSM

modem is fitted

• In case of wireless communication with the controllers, modules

SWB-C and SWB-R are needed.

• Alternatively, an RS232-RS485 converter mod. SBC485 has to

be fitted in case of a hard-wired system.

• GSM modem for sending SMS

Page 12: CATALOGUE - Sentien Electronicssentien-electronics.com.au/catalogues/SENTIEN_CATALOGUE.pdf · for a better protection between bezel and metal panel. TECHNICAL DATA CONTROL RANGE -50÷120°C

12

DAMPER ACTUATORS

ACTUATORS

PRODUCT SPECIFICATIONS

6 – 16Nm

0 – 90°

Spring Return Function

ON/OFF Control

24VAC/DC, 230VAC

TDF SERIES

PRODUCT SPECIFICATIONS

6 – 16Nm

0 – 90°

Spring Return Function

Modulating

24VAC, 230VAC

TAF SERIES

PRODUCT SPECIFICATIONS

2 – 4Nm

0 – 90°

ON/OFF Control

24VAC/DC, 230VAC

TD SERIES

PRODUCT SPECIFICATIONS

10 – 40Nm

0 – 90°

VAV Control

24VAC/DC, 230VAC

TV SERIES

PRODUCT SPECIFICATIONS

6 – 10Nm

0 – 90°

VAV Control

24VAC/DC, 230VAC

TV SERIES

PRODUCT SPECIFICATIONS100Nm6mmSpring Return FunctionON/OFF Control24VAC/DC, 230VAC

PRODUCT SPECIFICATIONS

10 – 40Nm

0 – 90°

ON/OFF Control

24VAC/DC, 230VAC

TD SERIES

PRODUCT SPECIFICATIONS

10 – 40Nm

0 – 90°

Modulating

24VAC/DC

TA SERIES

PRODUCT SPECIFICATIONS

6 – 10Nm

0 – 90°

ON/OFF Control

24VAC/DC, 230VAC

TD SERIES

PRODUCT SPECIFICATIONS

6 – 10Nm

0 – 90°

Modulating

24VAC/DC

TA SERIES

PRODUCT SPECIFICATIONS

2 – 4Nm

0 – 30° – 60° – 90°

ON/OFF Control

24VAC, 230VAC

TH SERIES

PRODUCT SPECIFICATIONS2 – 4Nm0 – 90°Spring Return FunctionON/OFF Control24VAC, 230VAC

Page 13: CATALOGUE - Sentien Electronicssentien-electronics.com.au/catalogues/SENTIEN_CATALOGUE.pdf · for a better protection between bezel and metal panel. TECHNICAL DATA CONTROL RANGE -50÷120°C

13

MINI CIRCUIT BREAKERS

CIRCUIT BREAKERS

YDZ47-60YDZ47-60 is an all new high performance current limiting

device with the ability to disconnect short circuits of up to 10kA.

And the most economy which is the newest model in the 21st

Century. YDZ47-60 MCB has many merits of high protective grade

(up to IP20) high breaking capacity, good realiability of sensitive

action, convenient multi-pole assorting, long using life etc.

They are mainly used for overload and short circuit protection

within the circuit of AC 50Hz, 230V in single pole 400V in two,

three ans four poles of lighting distribution systems in industrial

and commercial. They are also used in turning on and off electric

apparatus and lighting circuits under the normal condition.

PROPERTIES

CHARACTER STANDARD RATED CURRENT (A) POLES (P) RATING VOLTAGE (V) BREAKING CAPACITY (A)

B

C

D

IEC-8981, 2, 3, 4, 5, 6, 10, 16,

20, 25, 32, 40, 50, 60A

1 230 / 240 10000

2, 3, 4 400 / 415 6000

IEC-947-21, 2, 3, 4, 5, 6, 10, 16,

20, 25, 32, 40, 50, 60A

1130 20000

230 / 240 10000

2, 3, 4

400 / 415 3000

230 / 240 20000

400 / 415 10000

440 6000

YDZ47-60 3P

YDZ47-60 2P

YDZ47-60 1P

YDZ47-60

Page 14: CATALOGUE - Sentien Electronicssentien-electronics.com.au/catalogues/SENTIEN_CATALOGUE.pdf · for a better protection between bezel and metal panel. TECHNICAL DATA CONTROL RANGE -50÷120°C

14

RESIDUAL CURRENT CIRCUIT BREAKER

CIRCUIT BREAKERS

YF360-4P YF360-2P

SPECIFICATIONS

POLE NO. IN (A)

CAT.NO

I Δ N (MA)

30 100 300 500

4

25 DZ41030 DZ41100 DZ41300 DZ41500

40 DZ42030 DZ42100 DZ42300 DZ42500

63 DZ43030 DZ43100 DZ43300 DZ43500

SPECIFICATIONS

POLE

NO.

IN

(A)

CAT.NO

I Δ N (MA)

10 30 100 300 500

2

25 DZ21010 DZ21030 DZ21100 DZ21300 DZ21500

40 DZ22030 DZ22100 DZ22300 DZ22500

63 DZ23030 DZ23100 DZ23300 DZ23500

DIMENSIONSAPPLICATIONResidual Current Circuit Breaker provide the function of islation

switching and earth leakage protection of electrical circuits.

And also provide the indirect protection of the operator's body

against the dangerous effects of electric current and provide the

protection of the fire caused by the electrical circuit fault.

TECHNICAL DATASTANDARD IEC 1008, GB16916

RATED VOLTAGE (UN) 2 Pole: 230VAC

4 Pole: 400VAC

RATED CURRENT (IN) 25, 40, 63A

RATED RESIDUAL OPERATING CURRENT (IN)

10, 30, 100, 300, 500mA

RATED RESIDUAL NON-OPERATING CURRENT (IΔNO) 0.5 IΔn

RESIDUAL CURRENT OFF-TIME ≤0.1s

MINIMUM VALUE OF RATED MAKING AND BREAKING CAPACITY (IM) 630A

RATED CONDITIONAL SHORT-CIRCUIT CURRENT (INC)

In = 25.40A Inc = 1500A

In = 63A Inc = 3000A

ENDURANCE: ON LOAD 2000 cycles

OFF LOAD 2000 cycles

INSTALLATION• On Symmetrical DIN Rail

• Panel Mounting

YF360-III

Page 15: CATALOGUE - Sentien Electronicssentien-electronics.com.au/catalogues/SENTIEN_CATALOGUE.pdf · for a better protection between bezel and metal panel. TECHNICAL DATA CONTROL RANGE -50÷120°C

15

CIRCUIT BREAKERS

R7 ISOLATED SWITCHES

R7 1P R7 2P R7 3P R7 4P

APPLICATIONIt’s used for industry, commercial and

residential circuit electrical wire, used

as mainly switch IEC947.3 (EN60947.3).

STRUCTURE CHARACTERISTICS• Dual-Function connected wire terminal

• With indicator for contact status

• Can hand lock

• Lock Bore diameter is 6mm

SPECIFICATION

RATED VOLTAGE 240/415V

FREQUENCY 50/60 Hz

SHORT-CIRCUIT BEARS TO SUFFER CAPACITY Connected to 100A, Fuse to 25kA

MAKING OR BREAKING CAPACITY 1.25In; 1.1Ue

USAGE CATEGORY AC22

CONNECTION WIRE CUT Max. 50mm²

PROTECTION GRADE IP40 (Install the term)

INSULATEAppearance of clear and definate switch position

according to DIN VDEO106

DIMENSIONSRATED CURRENT

40 R7-40/1 R7-40/2

63 R7-63/1 R7-63/2

80 R7-80/1 R7-80/2

100 R7-100/1 R7-100/2

RATED CURRENT

40 R7-40/3 R7-40/4

63 R7-63/4 R7-63/4

80 R7-80/4 R7-80/4

100 R7-100/3 R7-100/4

1

2

1

2

3

4

1

2

3

4

5

6

1

2

3

4

5

6

7

8

Page 16: CATALOGUE - Sentien Electronicssentien-electronics.com.au/catalogues/SENTIEN_CATALOGUE.pdf · for a better protection between bezel and metal panel. TECHNICAL DATA CONTROL RANGE -50÷120°C

16

THREE POLE CONTACTORS

CONTACTORS

INSTANTANEOUS

AUXILIARY

CONTACTS

RATED

INSULATION

VOLTAGE

ACI

DUTY

0≥40°C

AC3

3 PHASE

AC3

1 PHASE

220V 380V 440V 575V 120V 230V

CATALOGUE

NAMEN / O N / C UI ITH IE

KWHP

KWHP

KWHP

KWHP

KWHP

KWHP

WEIGHT

KGAPPROVAL

SMC-09 1 1 1000V 20A 9A2.2

3

3.7

5

3.7

5

3.7

5

0.37

0.5

1.5

20.36

SMC-12 1 1 1000V 25A 12A3

4

5.5

7.5

5.5

7.5

5.5

7.5

0.55

0.75

1.5

20.36

SMC-18 1 1 1000V 32A 15A3.7

5

7.5

10

7.5

10

7.5

10

0.75

1

2.2

30.37

SMC-22 1 1 1000V 40A 22A5.5

7.5

11

15

11

15

11

15

1.5

2

3.7

50.37

SMC-32 2 2 1000V 50A 32A7.5

10

15

20

15

20

15

20

2.2

3

4

5.50.48

SMC-40 2 2 1000V 60A 42A11

15

19

25

19

25

19

25

3

4

5.5

7.50.48

SMC-50 2 2 1000V 80A 55A15

20

30

40

30

40

30

401.3

SMC-65 2 2 1000V 100A 65A19

25

33

45

33

45

33

451.3

SMC-80 2 2 1000V 110A 80A22

30

37

50

37

50

37

501.3

SMC-85 2 2 1000V 135A 105A25

35

45

60

55

75

55

751.3

NOTE SMC-32 ~ SMC85 includes of 2PCS SMC-D11

CATALOG NAME

APPLICABLE CONTACTORS

AUXILIARY N/O

CONTACTS N/C

INSULATION VOLTAGE

THERMAL CURRENT

WEIGHT KG APPROVAL

SMC-D11SMC-09 TO

SMC-851 1 660V 10A 0.034

NOTE SMC-09~SMC-22 includes 1PCS SMC-D11 only

10A MAX and 600VAC

UI 600V

ITH 10A

SMC-09 SMC-12 SMC-32 SMC-40 SMC-50 SMC-65 SMC-85

AUXILIARY CONTACTS BLOCKS / SMC-D11

“SMC” – SERIES 9A TO 105A (AC3)

Page 17: CATALOGUE - Sentien Electronicssentien-electronics.com.au/catalogues/SENTIEN_CATALOGUE.pdf · for a better protection between bezel and metal panel. TECHNICAL DATA CONTROL RANGE -50÷120°C

17

INSTANTANEOUS

AUXILIARY

CONTACTS

RATED

INSULATION

VOLTAGE

ACI

DUTY

0≥40°C

AC3

3 PHASE

AC3

1 PHASE

220V 380V 440V 575V 120V 230V

CATALOGUE

NAMEN / O N / C UI ITH IE

KWHP

KWHP

KWHP

KWHP

KWHP

KWHP

WEIGHT

KGAPPROVAL

C-06D10

C-06D01

1 -

- 11000V 16A 9A

2.2

3

3.7

5

3.7

5

3.7

5

0.2

1/3

1.1

1.50.177

C-09D10

C-09D01

1 -

- 11000V 20A 9A

2.2

3

5.5

7.5

5.5

7.5

5.5

7.5

0.37

0.5

1.5

20.350

C-11D10

C-11D01

1 -

- 11000V 25A 12A

3

4

5.5

7.5

5.5

7.5

5.5

7.5

0.55

0.75

1.5

20.350

C-12D10

C-12D01

1 -

- 11000V 25A 16A

4

5.5

7.5

10

7.5

10

7.5

10

0.75

1

2.2

30.350

C-18D10

C-18D01

1 -

- 11000V 32A 22A

5.5

7.5

11

15

11

15

11

15

1.5

2

3.7

50.350

C-25D10

C-25D01

1 -

- 11000V 40A 32A

7.5

10

15

20

15

20

15

20

2.2

3

4

5.50.525

C-35D10

C-35D01

1 -

- 11000V 50A 42A

11

15

19

25

19

25

19

25

3

4

5.5

7.50.550

C-45D11 1 1 1000V 60A 55A15

20

30

40

30

40

30

401.100

C-44D11 1 1 1000V 80A 65A19

25

33

45

33

45

33

451.100

C-65D11 1 1 1000V 90A 80A22

30

37

50

37

50

37

501.100

C-80D11 1 1 1000V 125A 105A25

35

45

60

55

75

55

751.100

C-100D11 1 1 1000V 130A 110A30

40

55

75

55

75

60

801.430

NOTE SMC-32 ~ SMC85 includes of 2PCS SMC-D11

THREE POLE CONTACTORS

CONTACTORS

C-06D10 C-12D10 C-18D10 C-25D10 C-35D10 C-45D11 C-80D11

“C” – SERIES 9A TO 100A (AC3)

Page 18: CATALOGUE - Sentien Electronicssentien-electronics.com.au/catalogues/SENTIEN_CATALOGUE.pdf · for a better protection between bezel and metal panel. TECHNICAL DATA CONTROL RANGE -50÷120°C

18

TH-12T3.50

THERMAL OVERLOAD RELAYS

CONTACTORS

THERMAL OVERLOAD RELAYS

“BTH”-SERIES 15A to 126A

CATALOGUE

NAME

RELAY SETTING

RANGE RC (FLC) A

STANDARD

A

CONTACTORS WEIGHT KG APPROVAL

BTH-60 12-18A 15A C-45D11 0.427

BTH-60 18-26A 22A C-45D11 0.427

BTH-60 26-40A 33A C-45D11 0.427

BTH-60 33-50A 41A C-45D11 0.427

BTH-60 43-65A 54A C-45D11 0.427

BTH-80 54-80A 67A C-45D11 0.427

BTH-80 64-96A 80A C-80D11(100D11) 0.427

BTH-80 85-126A 105A C-100D11 0.427

BTH-60

BTH-80

TH - 12 T 3.5 0 1 2 3 4

NTH - 17 2P S 1 2 3

1. CURRENT RATING (max.)

0.5 0.75 1.05 1.45 1.9 2.5 3 4 5 6.5

8 11 14 15 17 21 25 28 32 38 44

2. PHASE-FAILURE PROTECT

2P 2 Heaters

3P Phase-Failure

3. SEPARATE BLOCKS

NONE Normal

S Install

1. TYPE

12

20

60

120

3. CURRENT RATING (MEAN)

12 0.8 1.2 2.1 3.5 5 6.5

9 11 15

20 2.1 3.5 6.5 9 11 15 22 30 41

60 30 41 54 67 80

120 80 105 130

4. REAR CONNECTOR

NONE S-C Series

O C-Series

2. LOAD PLUG

NONE Normal

T Install

NTH-172PS

MODEL DESIGNATION

MODEL DESIGNATION

“BTH”SERIES 15A TO 126A• Compensated and Differential Overload Relays

• With 1 N/O + 1 N/C electrically Separated Auxillary Contacts

• For direct connection with “C”– Series Contactors

BTH SERIES

Page 19: CATALOGUE - Sentien Electronicssentien-electronics.com.au/catalogues/SENTIEN_CATALOGUE.pdf · for a better protection between bezel and metal panel. TECHNICAL DATA CONTROL RANGE -50÷120°C

19

NMS MANUAL MOTOR STARTERWith thermal overload and magnetic

short circuit releases.

CONTACTORS

MANUAL MOTOR STARTER

NMSB - 4.0 1 2

MODEL DESIGNATION

2. CURRENT RATING

0.63 1.0 1.6 2.5 4.0

6.3 10 15 25

1. TYPE

NMS Open

NMSB Moulded Plastic Enclosure

TYPE AMPERE SETTING WEIGHT (Kg)

MAX. BACK-UP FUSE (SLOW)A

3X220V 3X380V 3X440V 3X550V 3X660V 3X240V

3X425V (3X690V)

APPROVAL

NMS 0.63 0.40 – 0.63 0.230

No Back-up fuse

required, irrespective

of prospective

short-circuit current

Breaking Capacity

10KA at 3x220/240V

6KA at 3x380/440V

2.5A at 3x600V

NMS 1.0 0.63 – 1.0 0.230

NMS 1.6 1.0 – 1.6 0.230

NMS 2.5 1.6 – 2.5 0.230

NMS 4.0 2.5 – 4.0 0.230

NMS 6.3 4.0 – 6.3 0.230

NMS 10.0 6.3 – 10 0.230

NMS 15.0 10 – 16 0.230

NMS 25.0 15 – 25 0.230

NEUTRAL/PROTECTIVE CONDUCTOR(PEN)BAREnclosures NMSB can be fitted with a

second neutral/protective conductor(PEN)bar.

MOULDED PLASTIC ENCLOSURE NMSB (IP56)As enclosure NMSB, however with

seal and push-button diaphragm.

Degree of protection IP56.

INSTANTANEOUS AUXILIARY CONTACT BLOCKS (1PER BREAKER)

NMSB-4.0

NMS-15

NAS-11 NMSB-6.3 NMSB-46

NMS-15

Page 20: CATALOGUE - Sentien Electronicssentien-electronics.com.au/catalogues/SENTIEN_CATALOGUE.pdf · for a better protection between bezel and metal panel. TECHNICAL DATA CONTROL RANGE -50÷120°C

20

MS1-25D/35D

ENCLOSURES OF MAGNETIC STARTERS – MS1 IP65

CONTACTORS

MS1-09D/11D/12D/18D

DIMENSIONS (MM)

Page 21: CATALOGUE - Sentien Electronicssentien-electronics.com.au/catalogues/SENTIEN_CATALOGUE.pdf · for a better protection between bezel and metal panel. TECHNICAL DATA CONTROL RANGE -50÷120°C

21

ENCLOSURES OF MAGNETIC STARTERS MS1 IP65

CONTACTORS

MS1-25D/35D-R

MS1-09D/11D/12D/18D-R

DIMENSIONS (MM)

Page 22: CATALOGUE - Sentien Electronicssentien-electronics.com.au/catalogues/SENTIEN_CATALOGUE.pdf · for a better protection between bezel and metal panel. TECHNICAL DATA CONTROL RANGE -50÷120°C

22

ENCLOSURES OF MAGNETIC STARTERS MSP IP42

CONTACTORS

MSP21

MSP11

DIMENSIONS (MM)

Page 23: CATALOGUE - Sentien Electronicssentien-electronics.com.au/catalogues/SENTIEN_CATALOGUE.pdf · for a better protection between bezel and metal panel. TECHNICAL DATA CONTROL RANGE -50÷120°C

23

YF360 - 4P

DATALOGGERS

DATALOGGERS

BUILT-IN RS232

BUILT-IN RS232 INTERFACE DUAL TEMP. +RH WITH DISPLAY 88395

BUILT-IN RS232 INTERFACE DUAL TEMP. 88393/88394

RECORDING AIR TEMP. & EXT.TEMP (W/CONTACT PROBE) BUILD-IN RS232

INTERFACE W/O LOGGER CRADLE TO SETUP OR DOWNLOAD

3 STARTING MODES

1) Key start or stop

2) Schedule to start

3) Immediately start meets

IP65 waterproof rating

2 WAYS TO SETUP/DOWNLOAD

1) To PC: RS232/USB Cable

2) With Logger Printer 9801

W/Both Phonejacks cable: without

linking to PC Print available user

friendly software, easy to

set HI/LO ALM

TEMP. RANGE: -40~85°C, -40~185°C

EXTERNAL TEMP. RANGE -40 ~100°C (-40~212°F)

POWER BATTERY 3.0V Lithium Battery (CR2)

ACCURACY: TEMP.±0.6°C (-20~50°C)

±1.2°C (-40~20°C, 51~85°C)

MEMORY16000 points

(Temp. 8000 + Ext. Temp. 8000)

LCD DISPLAY Size: 13.5 x 33mm

DIMENSIONS (MM) 75.5mm x 53mm x 23.5mm (H x W x T)

LED SIGNAL Red (HI,LO Alarm) / Yellow (Record)

STANDARD PACKING Logger, Battery and Manual

OPTIONAL

RS232/USB cable W/Software or

9801 Logger Printer or RS232 to USB

converter to most PC comm. port.

RECORDING AIR TEMP. & EXT.TEMP (W/CONTACT PROBE)

BUILD-IN RS232 INTERFACE W/O LOGGER CRADLE TO SETUP OR DOWNLOAD

3 STARTING MODES

1) Key start or stop

2) Schedule to start

3) Immediately start meets

IP54 water resistant rating

2 WAYS TO SETUP/DOWNLOAD

1) To PC: RS232/USB Cable

2) With Logger Printer 9801

W/Both Phonejacks cable: without

linking to PC Print available user

friendly software, easy to

set HI/LO ALM

TEMP. RANGE -40~85°C, -40~185°C

EXTERNAL TEMP. RANGE -40~100°C (-40~212°F)

RH RANGE 0-100%

ACCURACY ±3% (10-90%), ±5% others

POWER BATTERY 3.0V Lithium Battery (CR2)

ACCURACY: TEMP. ±0.6°C (-20~50°C)

±1.2°C (-40~20°C, 51~85°C)

MEMORY16000points

(Air T.5333-Ext. T.53333+RH5333)

LCD DISPLAY Size: 13.5 x 33mm

DIMENSIONS (MM) 75.5mm x 53mm x 23.5mm (H x W x T)

LED SIGNAL Red (HI,LO Alarm) / Yellow (Record)

STANDARD PACKING Logger, Battery and manual

OPTIONALRS232/USB cable W/Software or 9801

Logger Printer or RS232 to USB converter

to most PC comm.port.

Page 24: CATALOGUE - Sentien Electronicssentien-electronics.com.au/catalogues/SENTIEN_CATALOGUE.pdf · for a better protection between bezel and metal panel. TECHNICAL DATA CONTROL RANGE -50÷120°C

24

FANS

THERMAL MANAGEMENT

SPECIFICATIONS

RATED

VOLTAGE

(VAC)

FREQU.

(Hz)

INPUT

POWER

(W)

RATED

CURRENT

(A)

LOCKED

CURRENT

(A)

SPEED

(RPM)

MAX.

AIRFLOW

(m³/min.)

MAX.

AIRFLOW

(CFM)

MAX.

PRESSURE

(mm H²0)

MAX.

PRESSURE

(inch H²0)

NOISE WEIGHT

MODEL

S063-1-HWB115 50 5 0,042 0,042 2.400 0,23 8,10 1,8 0,07 27 0,14

115 60 4 0,035 0,040 3.000 0,29 10,24 2,8 0,11 28 0,14

S063-2-HWB230 50 5 0,022 0,022 2.400 0,23 8,10 1,8 0,07 27 0,14

230 60 4 0,016 0,020 3.000 0,29 10,24 2,8 0,11 28 0,14

SPECIFICATIONS

RATED

VOLTAGE

(VAC)

FREQU.

(Hz)

INPUT

POWER

(W)

RATED

CURRENT

(A)

LOCKED

CURRENT

(A)

SPEED

(RPM)

MAX.

AIRFLOW

(m³/min.)

MAX.

AIRFLOW

(CFM)

MAX.

PRESSURE

(mm H²0)

MAX.

PRESSURE

(inch H²0)

NOISE WEIGHT

MODEL

S085-1-HWB115 50 15 0,15 0,16 2.600 0,59 21,0 4,0 0,16 32 0,26

115 60 11 0,12 0,13 3.100 0,68 24,0 4,5 0,22 35 0,26

S085-2-HWB230 50 16 0,08 0,09 2.600 0,59 21,0 4,0 0,16 32 0,26

230 60 14 0,07 0,08 3.100 0,68 24,0 5,5 0,22 35 0,26

S085-1-LWB115 50 14 0,14 0,15 1.900 0,40 15,0 2,0 0,08 28 0,26

115 60 11 0,12 0,13 2.400 0,50 18,0 3,5 0,14 31 0,26

S085-2-LWB230 50 16 0,07 0,08 1.900 0,40 15,0 2,0 0,08 28 0,26

230 60 14 0,06 0,07 2.400 0,50 18,0 3,5 0,14 31 0,26

S063 SERIES AC-FAN / AC-LÜFTER 60x60x30MM

S085 SERIES AC-FAN / AC-LÜFTER 80x80x25MM

S088 SERIES AC-FAN / AC-LÜFTER 80x80x38MM

SPECIFICATIONS

RATED

VOLTAGE

(VAC)

FREQU.

(Hz)

INPUT

POWER

(W)

RATED

CURRENT

(A)

LOCKED

CURRENT

(A)

SPEED

(RPM)

MAX.

AIRFLOW

(m³/min.)

MAX.

AIRFLOW

(CFM)

MAX.

PRESSURE

(mm H²0)

MAX.

PRESSURE

(inch H²0)

NOISE WEIGHT

MODEL

S088-1-HWB115 50 12 0,14 0,16 2.600 0,59 21,0 4,0 0,16 32 0,28

115 60 9 0,12 0,13 3.100 0,68 24,0 4,5 0,22 36 0,28

S088-2-HWB230 50 14 0,07 0,09 2.600 0,59 21,0 4,0 0,16 32 0,28

230 60 12 0,06 0,08 3.100 0,68 24,0 5,5 0,22 36 0,28

S088-1-LWB115 50 12 0,12 0,15 1.900 0,40 15,0 2,0 0,10 28 0,28

115 60 9 0,10 0,13 2.400 0,50 18,0 3,5 0,16 32 0,28

S088-2-LWB230 50 14 0,06 0,08 1.900 0,40 15,0 2,0 0,10 28 0,28

230 60 1 0,05 0,07 2.400 0,50 18,0 3,5 0,16 32 0,28

5

5-A

5-B

Page 25: CATALOGUE - Sentien Electronicssentien-electronics.com.au/catalogues/SENTIEN_CATALOGUE.pdf · for a better protection between bezel and metal panel. TECHNICAL DATA CONTROL RANGE -50÷120°C

25

THERMAL MANAGEMENT

FANS

SPECIFICATIONS

RATED

VOLTAGE

(VAC)

FREQU.

(Hz)

INPUT

POWER

(W)

RATED

CURRENT

(A)

LOCKED

CURRENT

(A)

SPEED

(RPM)

MAX.

AIRFLOW

(m³/min.)

MAX.

AIRFLOW

(CFM)

MAX.

PRESSURE

(mm H²0)

MAX.

PRESSURE

(inch H²0)

NOISE WEIGHT

MODEL

S128-1-HWB115 50 14 0,20 0,27 2.700 2,60 92,0 8,0 0,32 42 0,53

115 60 12 0,16 0,23 3.100 3,00 106,0 8,0 0,32 46 0,53

S128-2-HWB230 50 17 0,10 0,14 2.700 2,60 92,0 8,0 0,32 42 0,53

230 60 15 0,08 0,12 3.100 3,00 106,0 8,0 0,32 46 0,53

S128-1-MWB115 50 14 0,18 0,20 2.500 1,30 85,0 6,5 0,26 40 0,53

115 60 12 0,17 0,19 2.750 2,40 92,0 7,0 0,18 42 0,53

S128-2-MWB230 50 17 0,09 0,10 2.500 2,40 85,0 6,5 0,26 40 0,53

230 60 15 0,08 0,09 2.750 2,60 92,0 7,0 0,18 42 0,53

S128-1-LWB115 50 14 0,16 0,18 2.100 2,10 75,0 4,0 0,16 36 0,53

115 60 12 0,15 0,16 2.300 2,30 82,0 4,1 0,16 38 0,53

S128-2-LMB230 50 17 0,08 0,09 2.100 2,10 75,0 4,0 0,16 36 0,53

230 60 15 0,07 0,08 2.300 2,30 82,0 4,1 0,16 38 0,53

S128 SERIES AC-FAN / AC-LÜFTER 120x120x38MM

RS128 SERIES AC-FAN / AC-LÜFTER 120x120x38MM / REVERSE AIR-DIRECTION

SPECIFICATIONS

RATED

VOLTAGE

(VAC)

FREQU.

(Hz)

INPUT

POWER

(W)

RATED

CURRENT

(A)

LOCKED

CURRENT

(A)

SPEED

(RPM)

MAX.

AIRFLOW

(m³/min.)

MAX.

AIRFLOW

(CFM)

MAX.

PRESSURE

(mm H²0)

MAX.

PRESSURE

(inch H²0)

NOISE WEIGHT

MODEL

RS128-1-HWB115 50 13 0,20 0,22 2.700 2,40 85,0 8,0 0,32 45 0,53

115 60 11 0,19 0,20 3.100 2,80 99,0 8,5 0,33 47 0,53

RS128-2-HWB230 50 17 0,10 0,11 2.700 2,40 85,0 8,0 0,32 45 0,53

230 60 15 0,09 0,10 3.100 2,80 99,0 8,5 0,33 47 0,53

RS128-1-MWB115 50 13 0,18 0,20 2,500 2,20 78,0 6,0 0,24 43 0,53

115 60 11 0,17 0,19 2,750 2,40 85,0 6,5 0,26 45 0,53

RS128-2-MWB230 50 17 0,09 0,10 2,500 2,20 78,0 6,0 0,24 43 0,53

230 60 15 0,08 0,09 2,750 2,40 85,0 6,5 0,26 45 0,53

RS128-1-LWB115 50 13 0,16 0,18 2,100 1,90 67,0 3,8 0,15 36 0,53

115 60 11 0,15 0,16 2,300 2,10 75,0 4,0 0,16 38 0,53

RS128-2-LMB230 50 17 0,08 0,09 2,100 1,90 67,0 3,8 0,15 36 0,53

230 60 15 0,07 0,08 2,300 2,10 75,0 4,0 0,16 38 0,53

8

8-A

Page 26: CATALOGUE - Sentien Electronicssentien-electronics.com.au/catalogues/SENTIEN_CATALOGUE.pdf · for a better protection between bezel and metal panel. TECHNICAL DATA CONTROL RANGE -50÷120°C

26

FANS

THERMAL MANAGEMENT

SPECIFICATIONS

RATED

VOLTAGE

(VAC)

FREQU.

(Hz)

INPUT

POWER

(W)

RATED

CURRENT

(A)

LOCKED

CURRENT

(A)

SPEED

(RPM)

MAX.

AIRFLOW

(m³/min.)

MAX.

AIRFLOW

(CFM)

MAX.

PRESSURE

(mm H²0)

MAX.

PRESSURE

(inch H²0)

NOISE WEIGHT

MODEL

MS175-1-HWB115 50 42 0,52 0,88 2.800 5,5 195 14,0 0,55 49 1,10

115 60 42 0,47 0,75 3.250 6,5 230 16,0 0,63 53 1,10

MS175-2-HWB230 50 42 0,25 0,43 2.800 5,5 195 14,0 0,55 49 1,10

230 60 42 0,23 0,37 3.250 6,5 230 16,0 0,63 53 1,10

SPECIFICATIONS

RATED

VOLTAGE

(VAC)

FREQU.

(Hz)

INPUT

POWER

(W)

RATED

CURRENT

(A)

LOCKED

CURRENT

(A)

SPEED

(RPM)

MAX.

AIRFLOW

(m³/min.)

MAX.

AIRFLOW

(CFM)

MAX.

PRESSURE

(mm H²0)

MAX.

PRESSURE

(inch H²0)

NOISE WEIGHT

MODEL

S175-1-HWB115 50 26 0,24 0,58 2.850 5,8 205 14,0 0,55 61 1,08

115 60 30 0,25 0,58 3.400 6,8 241 18,5 0,73 66 1,08

S175-2-HWB230 50 26 0,11 0,58 2.850 5,8 205 14,0 0,55 61 1,08

230 60 31 0,13 0,58 3.400 6,8 241 18,5 0,73 66 1,08

MS175 SERIES AC-FAN / AC-LÜFTER Ø172x55MM / METAL-IMPELLER

S175 SERIES AC-FAN / AC-LÜFTER Ø172x55MM

S170 SERIES AC-FAN / AC-LÜFTER Ø172x150x51MM / THERMAL PROTECTION

SPECIFICATIONS

RATED

VOLTAGE

(VAC)

FREQU.

(Hz)

INPUT

POWER

(W)

RATED

CURRENT

(A)

LOCKED

CURRENT

(A)

SPEED

(RPM)

MAX.

AIRFLOW

(m³/min.)

MAX.

AIRFLOW

(CFM)

MAX.

PRESSURE

(mm H²0)

MAX.

PRESSURE

(inch H²0)

NOISE WEIGHT

MODEL

S170-1-HWB115 50 39 0,38 0,75 2.900 6,8 240 17,0 0,67 55 1,05

115 60 38 0,34 0,76 3.400 8,3 293 23,0 0,90 60 1,05

S170-2-HWB230 50 38 0,18 0,38 2.900 6,8 240 17,0 0,67 55 1,05

230 60 38 0,17 0,38 3.400 8,3 293 23,0 0,90 60 1,05

11

11-A

11-B

Page 27: CATALOGUE - Sentien Electronicssentien-electronics.com.au/catalogues/SENTIEN_CATALOGUE.pdf · for a better protection between bezel and metal panel. TECHNICAL DATA CONTROL RANGE -50÷120°C

27

UF133 – APA SERIES

S220 SERIES AC-FAN / AC-BACKWARD-CURVED-FAN / RÜCKWÄRTSGEKRÜMMTER-AC-LÜFTER Ø223x64MM / THERMAL PROTECTION

S180 SERIES AC-FAN / AC-AXIAL-FAN / AC-AXIALLÜFTER / Ø180x65MM / THERMAL PROTECTION

THERMAL MANAGEMENT

FANS

SPECIFICATIONS

RATED

VOLTAGE

(VAC)

FREQU.

(Hz)

INPUT

POWER

(W)

RATED

CURRENT

(A)

LOCKED

CURRENT

(A)

SPEED

(RPM)

MAX.

AIRFLOW

(m³/min.)

MAX.

AIRFLOW

(CFM)

MAX.

PRESSURE

(mm H²0)

MAX.

PRESSURE

(inch H²0)

NOISE WEIGHT

MODEL

UF133(72)APA

11H1S2A

115 50 38 0,50 0,83 2.780 4.66 335 16,6 0,65 50 0.9

115 60 37 0,43 0,72 3.200 5.33 370 22,4 0,88 60 0.9

UF133(72)APA

23H1S2A

230 50 36 0,24 0,39 2.780 4.66 335 16,6 0,65 50 0.9

230 60 35 0,21 0,34 3.200 5.33 370 22,4 0,88 60 0.9

SPECIFICATIONS

RATED

VOLTAGE

(VAC)

FREQU.

(Hz)

INPUT

POWER

(W)

RATED

CURRENT

(A)

LOCKED

CURRENT

(A)

SPEED

(RPM)

MAX.

AIRFLOW

(m³/min.)

MAX.

AIRFLOW

(CFM)

MAX.

PRESSURE

(mm H²0)

MAX.

PRESSURE

(inch H²0)

NOISE WEIGHT

MODEL

S225-1-HWB115 50 90 0,77 1,19 2.500 14,0 500 15,0 1,4 65 1,30

115 60 117 0,98 1,22 2.650 15,0 530 16,0 1,5 70 1,30

S225-2-HWB230 50 90 0,40 0,60 2.500 14,0 500 15,0 1,4 65 1,30

230 60 117 0,50 0,58 2.650 15,0 530 16,0 1,5 70 1,30

SPECIFICATIONS

RATED

VOLTAGE

(VAC)

FREQU.

(Hz)

INPUT

POWER

(W)

RATED

CURRENT

(A)

LOCKED

CURRENT

(A)

SPEED

(RPM)

MAX.

AIRFLOW

(m³/min.)

MAX.

AIRFLOW

(CFM)

MAX.

PRESSURE

(mm H²0)

MAX.

PRESSURE

(inch H²0)

NOISE WEIGHT

MODEL

S280-1-HWB115 50 76 0,70 1,23 2.750 9,5 335 7,5 0,3 62 1,20

115 60 75 0,71 1,23 3.100 11,0 388 10,0 0,4 65 1,20

S280-2-HWB230 50 76 0,35 0,54 2.750 9,5 335 7,5 0,3 62 1,20

230 60 75 0,40 0,54 3.100 11,0 388 10,0 0,4 65 1,20

16-A

16-B

Page 28: CATALOGUE - Sentien Electronicssentien-electronics.com.au/catalogues/SENTIEN_CATALOGUE.pdf · for a better protection between bezel and metal panel. TECHNICAL DATA CONTROL RANGE -50÷120°C

28

80x80MM ART.-NR. G80-18 60x60MM ART.-NR. G60-4

THERMAL MANAGEMENT

FANS

ACCESSORIES / METAL FINGER GUARDS 18

119x119MM ART.-NR. G109-15A 92x92MM ART.-NR. G92-16

Page 29: CATALOGUE - Sentien Electronicssentien-electronics.com.au/catalogues/SENTIEN_CATALOGUE.pdf · for a better protection between bezel and metal panel. TECHNICAL DATA CONTROL RANGE -50÷120°C

29

ELECTRONIC FAN SPEED CONTROL

FAN SPEED CONTROLS

ELECTRONIC SPEEDCONTROLLER FOR SINGLE PHASE MOTORSCURRENT MAX. 4 AMPS

POWEER SUPPLY 230V-1, Ph-50/60 Hz, min. 180V, max. 260V

EU-CONFORMITY CE – SIGN

Electronical Filter according EMV-89/336/EEC and ICE801-2 cl.4

CONNECTIONS: POWER SUPPLY

Removable screw-type connectionsfor max. 2.5mm²

SENSORS

Removable screw-type connections for max. 2.5mm²

PRODUCT INFORMATION

TECHNICAL DATA POWER SUPPLY APPLICATION

AMBIENT TEMPERATURES

Temperatures -20ºC ./. +55ºC

Humidity <90% r.H. not condensing

ANALOGUE – INPUT

1 x Presssure Transducer 4 – 20mA

1 x Temperature Sensor NTC (10 kOhm)

Max. Starting Current

2 x Nominal Current for max. 10 sec

ADR 40 – BOARD TO BE INSTALLED

IN CABINETS IP 24

Dimensions W x H x D : 90 x 85 x 40 mm

ADR 40 DP – IN ALU DIE CAST BOX, IP 55

Dimensions W x H x D : 97 x 120 x 60 mm

ADR 40 PP – IN PLASTIC BOX IP 54

Dimensions: W x H x D : 170 x 150 x 50 mm

SINGLE PHASE 230 Volts, 50 – 60 Hz

MIN. POWER SUPPLY 180 Volts

PRESSURE RANGE WITH PRESSURE TRANSDUCER

Min. +10 bars Max. +40 bars

TEMPERATURE RANGE WITH NTC-SENSOR

Min. -20°C Max. +100°C

PRESSURE CONTROL

The setup of the requested set points and also

the range of the proportional band has to be

done by adjusting two trimmer which are placed

on the board.

TEMPERATURE CONTROL

The setup of the requested set points and

also the range of the proportional band

has to be done by adjusting two trimmer

which are placed on the board.

The adjustment of the trimmer is always

for the connected pressure transducer or

the temperatur sensor.

NO EXTERNAL REMOTE CONTROL NECESSARY

CHILLER / HEAT PUMP

The Speed Controller ADR 40

can be used in chiller applications

(increasing temperature = increasing speed)

as well as heat pump applications

(increasing temperature = decreasing speed).

Heat pump applications are possible to control

only by using pressure transducers 4-20 mA.

By using ADR 40 in heat pump applications a

bridge has to be made on the NTC connection.

In pressure control for safety reasons or particular

requirements a NTC-Sensor could be installed

in addition to the pressure transducer. In case

that measured temperatures exceed 90°C the

speed controller will stop the motor and drop in

again according to the measured pressure when

temperature undergoes 90°C.

At new starts motors are always forced for

some seconds to run at 70% of the speed.

In case of breakdowns of the board the

ADR fails to safe.

FUNCTION DIAGRAM CHILLERBETRIEB

SET PROP

ADR 40

%

ºC/BARmin

ºC/BARmax

0

min

(max + min)/2

max

SET

Page 30: CATALOGUE - Sentien Electronicssentien-electronics.com.au/catalogues/SENTIEN_CATALOGUE.pdf · for a better protection between bezel and metal panel. TECHNICAL DATA CONTROL RANGE -50÷120°C

30

ELECTRONIC FAN SPEED CONTROL

FAN SPEED CONTROLS

ELECTRONIC FAN SPEED CONTROLLER PRESSURE – OR TEMPERATURE CONTORLS FOR SINGLE– AND THREE PHASE MOTORS CURRENT MAX. 8 AMPS

POWER SUPPLY: 230V/400V-3 Ph – 50/60 Hz

230V-1 Ph – 50/60 Hz

EU-CONFORMITY CE

Electronical Filter according EMV - 89/336/EEC and ICE801-2 cl.4

CONNECTIONS POWER SUPPLY

Removable screw-type connectionsfor max. 16mm²

SENSORS

Removable screw-type connections for max. 2.5mm²

PRODUCT INFORMATION

TECHNICAL DATA INTERGRATED SOFTWARE ACCESSORIES

AMBIENT TEMPERATURES

Temperatures -10ºC ./. -55ºC

Humidity less than 90% R.F. not condensing

ANALOGUE – INPUT

2 x Multifunction, 4 – 20mA

0 – 20mA

0 – 10V, NTC (selectable)

SERIAL INTERFACE

System Micronova Type RS 422 or RS 485

and connection to Modern, GCM

MAX. STARTING – CURRENT

Double of nominal data for max. 10 sec

AVAILABLE MODELS:

ADR 80 – BOARD IP 24

Dimensions W x H x D : 198 x 160 x 55 mm

ADR 80 DP – IN HOUSE

Dimensions W x H x D : 315 x 255 x 180 mm

MODEL "DP" – IP 55

PROGRAMMABLE BY USING

MULTILINGUAL LCD – DISPLAY

LANGUAGES

English, German, Italian

POWER SUPPLY

Single – or three Phase

DUALSET – CONTROL (VERSION 4)

Also with two different sensors

AVAILABLE REFRIGERANT DATA

R22, R134A, R407C, R404A, R507

PRESSURE CONTROL

Data Input in Bar or ºC

TEMPERATURE CONTROL

between -20ºC to 80ºC

SPEED REGULATION WITH EXTERNAL CONTROL

Regulation by external signal 0-10V

PROGRAMMABLE OUTPUT – VOLTAGE

Maximum 0% to 100%

Minimum 0% to 100%

FAN – START WITH 100%

Programmable between 0 to 10 sec

IDENTIFYING POWER- FACTOR (COSΦ)

OF THE MOTOR

For improvement of the control

SENSOR AND / OR PRESSURE – TRANSDUCER

Programmable number, input-signal and max.

working limits.

NETWORK SOFTWARE

All ADR – controllers can be used and

adjusted externally by using the microvision

network software.

THE PRINCIPLES OF ADR CONTROL

ACCESSORIES

REMOTE – CONTROL LCD 2000

With 4 push-buttons, two-lines – Display with

16 digits, height 5mm, for installation in front

door, IP 55 including connecting cord 0.9m.

PMT – PRESSURE TRANSDUCER WITH

7/16UNF FEMALE THREAD SCHRADER

4 – 20mA, working-pressure: 7,18 or 30bar.

PMT-V – PRESSURE TRANSDUCER WITH

7/16UNF FEMALE THREAD SCHRADER

0 – 10V, working-pressure: 7,18 or 30bar.

NTC – TEMPERATURE-SENSOR

Standard Length: 6m

SWPC – SOFTWARE "MICROVISION"

Software for Supervision on Windows™

Base and Graphic Illustration.

REMOTE – CONTROL BY MODERN

Software for Single Remote-Control or

adjustment by PC.

DP – HOUSING IP 55

Prepared for installation of LCD-Display

c/w setting material.

Start Set

ProprtionalBand

Max

Pressure orTemperature

%min

%max

max

Speed

ADR 80

Page 31: CATALOGUE - Sentien Electronicssentien-electronics.com.au/catalogues/SENTIEN_CATALOGUE.pdf · for a better protection between bezel and metal panel. TECHNICAL DATA CONTROL RANGE -50÷120°C

31

ELECTRONIC FAN SPEED CONTROL

FAN SPEED CONTROLS

ELECTRONIC FAN SPEED CONTROLLER PRESSURE – OR TEMPERATURE CONTROLS FOR SINGLE – AND THREE PHASE MOTORSCURRENT MAX. 23 AMPS

POWER SUPPLY 230V/400V-3 Ph – 50/60 Hz

230V-1 Ph – 50/60 Hz

EU-CONFORMITY CE – SIGN

Electronical Filter according EMV – 89/336/EEC and ICE801-2 cl.4

CONNECTIONS POWER SUPPLY

Removable screw-type connectionsfor max. 16mm²

SENSORS

Removable screw-type connections for max. 2.5mm²

PRODUCT INFORMATION

TECHNICAL DATA INTERGRATED SOFTWARE ACCESSORIES

AMBIENT TEMPERATURES

Temperatures -10ºC ./. -55ºC

Humidity less than 90% R.F. not condensing

INPUT 1 x potential-free

ANALOGUE – INPUT

2 x Multifunction, 4 – 20mA

0 – 20mA

0 – 10V, NTC (selectable)

SERIAL INTERFACE:

System Micronova Type RS 422 or RS 485

and connection to Modern, GCM

MAX. STARTING – CURRENT

Double of nominal data for max. 10 sec

AVAILABLE MODELS

ADR 80 – BOARD IP 24

Dimensions W x H x D: 198 x 190 x 87 mm

ADR 80 DP – IN HOUSE

Dimensions W x H x D: 315 x 255 x 230 mm

MODEL "DP" – IP 55

PROGRAMMABLE BY USING

MULTILINGUAL LCD – DISPLAY

LANGUAGES

English, German, Italian

POWER SUPPLY

Single – or three Phase

DUALSET – CONTROL (VERSION 4)

Also with two different sensors

AVAILABLE REFRIGERANT DATA

R22, R134A, R407C, R404A, R507

PRESSURE CONTROL

Data Input in Bar or ºC

TEMPERATURE CONTROL

between -20ºC to 80ºC

SPEED REGULATION WITH EXTERNAL CONTROL

Regulation by external signal 0-10V

PROGRAMMABLE OUTPUT – VOLTAGE

Maximum 0% to 100%

Minimum 0% to 100%

FAN – START WITH 100%

Programmable between 0 to 10 sec

IDENTIFYING POWER – FACTOR (COSΦ)

OF THE MOTOR

For improvement of the control

SENSOR AND / OR PRESSURE – TRANSDUCER

Programmable number, input-signal and max.

working limits.

NETWORK SOFTWARE

All ADR – controllers can be used and

adjusted externally by using the microvision

network software.

THE PRINCIPLES OF ADR CONTROL

ACCESSORIES

REMOTE – CONTROL LCD 2000

With 4 push-buttons, two-lines – Display with

16 digits, height 5mm, for installation in front

door, IP 55 including connecting cord 0.9m.

PMT – PRESSURE TRANSDUCER WITH

7/16UNF FEMALE THREAD SCHRADER

4 – 20mA, working-pressure: 7,18 or 30bar.

PMT–V – PRESSURE TRANSDUCER WITH

7/16UNF FEMALE THREAD SCHRADER

0 – 10V, working-pressure: 7,18 or 30bar.

NTC – TEMPERATURE-SENSOR

Standard Length: 6m

SWPC – SOFTWARE "MICROVISION"

Software for Supervision on Windows™

Base and Graphic Illustration.

REMOTE – CONTROL BY MODERN

Software for Single Remote-Control

or adjustment by PC.

DP – HOUSING IP 55

Prepared for installation of LCD-Display

c/w setting material.

Start Set

ProprtionalBand

Max

Pressure orTemperature

%min

%max

max

Speed

ADR 230

Page 32: CATALOGUE - Sentien Electronicssentien-electronics.com.au/catalogues/SENTIEN_CATALOGUE.pdf · for a better protection between bezel and metal panel. TECHNICAL DATA CONTROL RANGE -50÷120°C

32

ELECTRONIC FAN SPEED CONTROL

FAN SPEED CONTROLS

REMOTE – CONTROL WITH LCD – DISPLAY APPLICATIONS:Boards with Microprocessor

FOR EXAMPLE

• Boards CB 2000, CB 1000 (MP0606)

• Controller ADR 70, 80 and 230

PRODUCT INFORMATION

TECHNICAL DATA INTERGRATED SOFTWARE

TECHNICAL DATA DISPLAY LCD 2000

INDICATOR

LCD – Display

2 lines with each 16 digits per line

Digit Height: 5mm

CONNECTION WITH BOARD

Connection cable 0.9m, max. length 4m

POWER SUPPLY

By connecting cable with the board.

AMBIENT TEMPERATURES

Temperatures 0ºC – 60ºC

Humidity less than 90% R.F. not condensing

PROTECTION DISPLAY

With front panel installation IP 55

HOUSING

Of robust, not flammable plastic.

DIMENSIONS OF DISPLAY

Frontal: 14.5 cm x 3.7 cm, depth: 1.5 cm

PUSH-BUTTONS FOR USAGE AND PROGRAMMING

Numbers: 4

LED – INDICATOR FUNCTION AND STATUS:

Numbers: 2

OPTION: MI-LCDR

Additional board for long distance installations of the

display. Connection throguh 2-wire telephone cable.

Maximum distance is 1 km. One the board itself as

additional display can be installed.

BESIDES THE STANDARD VERSION OF THE LCD – REMOTE – CONTROL A BIG

VARIETY OF FRONT PANELS ARE AVAILABLE. THE FRONT PANELS CAN BE

STYLED INDIVIDUALLY ACCORDING TO CUSTOMER REQUESTS.

The philosophy, inder which Micronova developed this range, is to give the user for low

cost (only a change of the Polycarbonate surface) a maximum of graphical freedom.

The display therefore can be intergrated visually perfect in the finished product of the

customer. Because of the large variety of displays with different LED, digit-indicators,

push-buttons and different dimensions there is an even larger product differentiation

possible. This can and will be all supported by a customer specific Software Development,

accordingly guaranteeing exclusive functions and optics.

REMOTE – CONTROL MODULAR – SYSTEM

MICRONOVA offers a large range of LCD-Displays, that are compatible with different boards

and Microprocessors.

ADVANTAGES OF THE LCD-DISPLAY

The advantages are the possibilities to communicate directly with the user and thereby

reduce or eliminate user faults.

D-LCD 2000

Page 33: CATALOGUE - Sentien Electronicssentien-electronics.com.au/catalogues/SENTIEN_CATALOGUE.pdf · for a better protection between bezel and metal panel. TECHNICAL DATA CONTROL RANGE -50÷120°C

33

HEATING ELEMENT

HEATING ELEMENTS

STAINLESS STEEL TUBULAR HEATING ELEMENTSTYPICAL APPLICATIONS Defrosting evaporators for commercial

and industrial refrigerators, incubators for poultry industry,

industrial applications, ironing presses, counter heating, hotplates...

INFORMATION• Tubes in Stainless Steel Aisi 304 or Aisi 321 or Incoloy 800,

diameter 8.5mm and diameter 6.5mm.

• Silicone double insulated cable.

• Waterproof end moulding with silicone.

• Silicone vulcanizated tapered ends with diam. as per Aisi tube.

• Maximum Asis tube length over 5mt.

• Earth connection with welded-on screw M4x10 or welded-on

male faston 6.3x0.8.

• Element bending, voltage and power as per customer drawing.

• Maximum sheath temperature: 550ºC.

• VDE approval for items up to 3W/cm²

• Test according to IEC EN60335-1 and CENELEC

HD289 S1 standards.

HEATING ELEMENTS

ADR 230

TYPICAL CONSTRUCTION

DIAGRAM TEMPERATURE

ON FREE AIR

ON DISSIPATOR

Page 34: CATALOGUE - Sentien Electronicssentien-electronics.com.au/catalogues/SENTIEN_CATALOGUE.pdf · for a better protection between bezel and metal panel. TECHNICAL DATA CONTROL RANGE -50÷120°C

34

THERMOMETERS

METERS

The CFM-01 is a valuable tool in the measurement of Air Flow and Air Temperature and will

automatically calculate CFM's & CMM (cubic ft. per minute and cubic meters per minute).

Instant/Average and 2/3V max Flow Measurements are simply and easily obtained using the

12key pads to enter the duct or hood area in feet or be measred in m/s, ft/min, knots, km/hr.

and mph. Temperature readings are obtained with a fast response type K thermocouple.

• CFM made easy • Large LCD Dual Display

• ºF / ºC • Auto Off – 9V Battery and Carrying Case included

SPECIFICATIONSDISPLAY 1/2" & 3/8" digits.

BEARING Sapphire Jewel Bearing.

OPERATING TEMPERATURE

Meter 32ºF - 122ºF (0ºC - 50ºC), Vane 32ºF-140ºF (0ºC - 60ºC)

OPERATING HUMIDITY

Less than 80% RH

RANGE OF WIND TEMPERATURE RANGE OF WIND VELOCITY

UNITS RANGE RESOLUTION ACCURACY UNITS RANGE RESOLUTION ACCURACY

ºC 0.0 – 45.0 0.2 ±1.0ºC m/s 0.0 – 45.0 0.1 ±3% ± 0.1

ºF 32.0 – 113.0 0.36 ±1.8ºF ft/min 0.0 – 8800 0.1/1 ±3% ± 10

knots 0.0 – 88.0 0.1 ±3% ± 0.1

Km/hr 0.0 – 140.0 0.1 ±3% ± 0.1

mph 0.0 – 100.0 0.1 ±3% ± 0.1

CFM-01

CAT NO. DESCRIPTION IDN

CFM-01 Thermo-Anemometer 61405

These instruments are the leader in Solar Powered technology

as we now offer ten different versions of our Digital thermometers.

Available in super low light versions 56SD, 72SD, 25SD (8 Lux) and

low light (18 Lux) Series 20SD. These "self powered" thermometers

operate without any batteries and offer an attractive and modern

update to existing refrigeration equipment. Each thermometer has

adjustable calibration, a ten second update time and wide ambient

temperature specifications for both indoor and outdoor installations.

Where customers prefer LED, We offer our 2" retrofit unit, the 20DT.

Now with 110V direct power (No transformer needed) and 1/2" high

intensity red readout. All the digital thermometers are NSF listed.

(1) Equivalent "C available, consult Factory

(2) Features "F/"C switch.

(3) Longer line lengths available

(4) Offered in black or white case.

SERIES SD-LCD

CAT. NO. CASE RANGE (1) SENSOR LENGTH (3) IDN

20SD-BS Back Flange 40/0/160°F 05ft 60110

20SD-HL Hanging 40/0/160°F 05ft 60160

20SD-FS Front Flange 40/0/160°F 05ft 60100

25SD-160Horiz. Wall

Mount (4)40/0/160°F 05ft 60170

56SD-230 Front Flange 40/0/230°F (2) 05ft 60120

72SD-F-160 Front Flange 40/0/160°F 05ft 60140

72SD-U-160 U-Clamp 40/0/160°F 05ft 60150

SERIES DT-LCD

CAT. NO. CASE RANGE SENSOR LENGTH IDN

20DT-F Front Flange 40/0/230°F 05ft 60520

20DT-U U-Clamp 40/0/230°F 05ft 60530

ECONOMY BATTERY TYPE PANEL METER

CAT. NO. CASE RANGE SENSOR LENGTH IDN

LCD58 Panel Mount with Clips 40/0/230°F 04ft 60205

DIGITAL THERMO – ANEMOMETER

56SD-230, 72SD-F, 25SD-160 20DT-F, 20SD-F, 20SD-HL

REMOTE READING DIGITAL THERMOMETERS

LC58

Page 35: CATALOGUE - Sentien Electronicssentien-electronics.com.au/catalogues/SENTIEN_CATALOGUE.pdf · for a better protection between bezel and metal panel. TECHNICAL DATA CONTROL RANGE -50÷120°C

35

DIGITAL THERMOMETER

METERS

# 305• -58/1300ºC and -58/2000ºF Selectable.

• Reading Hold and Maximum Record Function. K–Type

• Thermocouple Input

• 0.1ºC/0.1ºF Resolution

• Single Input and Supply with 1 Pcs 4 Feet Probe

# 307• -58/1300ºC and -58/2000ºF Selectable.

• Reading Hold and Maximum Record Function. K–Type

• Thermocouple Input

• 0.1ºC/0.1ºF Resolution

• Dual Input with Differential Temperature

• (T1 – T2) and Supply. With 2 Pcs 4 Feet Probe

TPK-01 BEAD PROBEMeasures surface or Air Temperature to 200ºC (392ºF) 4Ft. long wire

has an Industry Standard Miniature Connector Plug.

TPK-03 IMMERSION PROBEGeneral Purpose Needle Type with Stainless Sheath use for

measurements up to 800ºC (1472ºF).

TPK-04 SURFACE PROBEMiniature, Fast Response Probe, with 800ºC (1472ºF) Max. Surface

Temperature. Ideal for measuring the Surface Temperature of small

electronic parts.

# 400L• CE Approval

• ºF / ºC Selectable

• Built-in Laser Pointer to Improve Aim

• Narrow Field of View (At 12º Distance Measure 1º Target)

• Resolution 0.1ºF / 0.1ºC

• Dimensions 175 x 39 x 72 mm, Weight: 179 Grams

• Fixed Emissivity 0.95

• Distance Spot = 12.1

• Temp. Range -60~500ºC (-76~932ºF)

• Operating Range 0~50ºC (32 ~ 122ºF)

• Accuracy +/-1.0ºC (+/-1.8ºF)

• Auto-Hold and Power-Off Function

• Back Light

• Battery Life Typical 18 Hours Continuous Use

RT-905A• CE Approval

• -50/200ºC & -58/392ºF Switchable

• Max/Min Temperature Memory

• Data Hold Function

• High/Low Temperature Alarm Setting

• Key Tone for Operation Confirmation

• Foldaway Stand

• Stainless Steel Probe 3.5mm x 125mm

with 1m Long Wire

APPLICATIONS

Food Processing, Laboratory Pharmaceutical,

Agriculture, Other Purposes.

HAND HELD THERMOMETER TYPE K THERMOCOUPLE PROBES

NON-CONACT LASER INFRARED THERMOMETER HAND HELD DIGITAL THERMOMETER

DIGITAL THERMOMETER

TPK-04

TPK-03

TPK-01

Page 36: CATALOGUE - Sentien Electronicssentien-electronics.com.au/catalogues/SENTIEN_CATALOGUE.pdf · for a better protection between bezel and metal panel. TECHNICAL DATA CONTROL RANGE -50÷120°C

36

METERS

THERMOMETERS

Accurate Humidity measurement at reasonable cost with usable functions is what best describes the RHT-1

Series. This rugged hand held instrument features a wide humidity measurement range from 10% to 95%

and a temperature range from -4ºF to 140ºF (-20 to 60ºC). Accuracy of 2% RH and 1ºF plus an ºF/C switch,

Hold feature and Output Jack make the RHT-1 ideal for HVAC and Refrigeration applications. The precision

capacitance humidity sensor offers fast response and the output jack offers the ability to record data or

remotely monitor both temperature and humidity. These features are normally found on instruments costing

much more than the reasonably priced RHT-1, complete with 400 hour 9V battery and case.

CAT NO. DESCRIPTION IDN

RHT10% – 95% RH

4/0/140°F61300

HT2096

GENERAL DETAILS

WEIGHTS 200gm (7oz.)

DIMENSIONS 10.6"L x 2.7"W x 1.0"H (270 x 68 x 25mm)

BATTERY Standard 9V (NEDA 1604, 6F22 or 006P)

BATTERY LIFE Approx. 400 Hours

LOW BATTERY INDICATION "BT" indicates on the display

SERIES HT2096

CAT. NO. RANGE IDN

HT2096F 40/0/122°F 39170

HT2096C40/0/70°C

15% – 95% RH39175

DIGITAL TEMPERATURE HUMIDITY TESTER

REMOTE READING DIGITAL THERMOMETERS

RHT – 1

SPECIFICATIONS

ELECTRICAL

DISPLAY 3-1/2 Digits, 1/2" LCD Display

RANGEHumidity 10% – 95 % RH

Temperature: -20 –140ºF, -30 – 60ºC

RESOLUTION 0.1%RH, 0.1ºF, 0.1ºC

ACCURACY

Humidity: 2% RH at 25ºC, 30 – 95% RH

5% RH at 25ºC, 10 – 30% RH

Temperature: ± 1.0ºF, ±0.8ºC

SENSOR TYPEHumidity: Precision Gold Capacitance Sensor

Temperature: Semiconductor Sensor

RESPONSE TIME

Humidity: 45% – 95%, 3 minutes

95% – 45%, 5 minutes

Temperature: 1ºC /2 seconds

SAMPLING RATE 2.5 times per second

AUIXILIARY OUTPUTSHumidity: 10mVdc / 1% RH

Temperature: 10mVdc / 1ºC

ENVIRONMENTAL

OPERATING TEMPERATURE & HUMIDITY32ºF – 122ºF (0ºC – 50ºC) . 85% RH

*(-20 to 140ºF will operate for limited time period)

STORAGE TEMPERATURE & HUMIDITY -10 to 60ºC, 14 to 140ºF . 70% RH

• Temperature, Humidity Indicator

• Desktop or Walll Mounted

• Compact Design

Page 37: CATALOGUE - Sentien Electronicssentien-electronics.com.au/catalogues/SENTIEN_CATALOGUE.pdf · for a better protection between bezel and metal panel. TECHNICAL DATA CONTROL RANGE -50÷120°C

37

OVERAL DIMENSIONS

ROUND THERMOMETER

METERS

DETAILS

Round Thermometer, DIN Scale, Liquid sensing Bulb,

Suitable for boilers, refrigerators, catering equiptments

and household appliances.

ALL MODELS ARE SUPPLIED WITH THREADED TIE-ROD

UPON REQUEST WE CAN SUPPLY

• Dial, numbers and body in different colours

• Temperature scale customer designed

• Different capillary lengths available

• Bulb wit other dimensions

• Quick coupling customer designed

• Head compensation against ambient temperature fluctuations

TECHNICAL DATA

MAX. WITHSTANDING BODY TEMPERATURE 80ºC

BULB BRASS OR COPPER ø 6.5 mm

COPPER CAPILLARY LENGTH 1000 mm

MIN. CAPILLARY BENDING RADIUS 5 mm

MEASURING SYSTEM: BOURDON RADIUS

BLACK PLASTIC HOUSING

PLAIN BLACK FRAME

FASTENING BY SELF-LOCKING GILLS

STANDAR TYPES

MODEL 010259

RANGE 0 / 120ºC

BLACK DIAL / WHITE INSCRIPTIONS

CALIBRATED AT 30ºC ± 2ºK

MODEL 10548

RANGE 0 / 200ºC

BLACK DIAL / WHITE INSCRIPTIONS

CALIBRATED AT 80ºC ± 5ºK

MODEL 10836

RANGE 50ºC /120ºC

BLACK DIAL / WHITE INSCRIPTIONS

CALIBRATED AT 80ºC ± 5ºK

MODEL 010473

RANGE -40ºC / +40ºC

BLACK DIAL / WHITE INSCRIPTIONS

CALIBRATED AT -20ºC ± 2ºK

T. MAX CAPILLARY PVC COVERED 80ºC

MODEL 902

Page 38: CATALOGUE - Sentien Electronicssentien-electronics.com.au/catalogues/SENTIEN_CATALOGUE.pdf · for a better protection between bezel and metal panel. TECHNICAL DATA CONTROL RANGE -50÷120°C

38

RECTANGULAR THERMOMETER

METERS

DETAILS

Rectangular thermometer, Drum Dial, Liquid sensing bulb, suitable

for refrigerators and high temperature appliances.

ALL MODELS ARE SUPPLIED WITH THREADED TIE-ROD

UPON REQUEST WE CAN SUPPLY

• Dial, numbers and body in different colours

• Temperature scale customer designed

• Different capillary lengths available

• Capillary PVC Covered

• Bulb wit other dimensions

• Head compensation against ambient temperature fluctuations

TECHNICAL DATA

MAX. WITHSTANDING BODY TEMPERATURE 70ºC

BULB BRASS OR COPPER ø 6.5 mm

COPPER CAPILLARY LENGTH 1000 mm

MIN. CAPILLARY BENDING RADIUS 5 mm

MEASURING SYSTEM: BOURDON RADIUS

BLACK PLASTIC HOUSING

PLAIN BLACK FRAME

FASTENING BY SELF-LOCKING GILLS

STANDAR TYPES

MODEL 20656

RANGE 0 / 200ºC

BLACK DIAL / WHITE INSCRIPTIONS

CALIBRATED AT 80ºC ± 5ºK

MODEL 20944

RANGE 50 / 350ºC

BLACK DIAL / WHITE INSCRIPTIONS

CALIBRATED AT 80ºC ± 5ºK

MODEL 02038

RANGE -40ºC / +40ºC

BLACK DIAL / WHITE INSCRIPTIONS

CALIBRATED AT -20ºC ± 2ºK

T. MAX CAPILLARY PVC COVERED 80ºC

MODEL 922

OVERALL DIMENSIONS

Page 39: CATALOGUE - Sentien Electronicssentien-electronics.com.au/catalogues/SENTIEN_CATALOGUE.pdf · for a better protection between bezel and metal panel. TECHNICAL DATA CONTROL RANGE -50÷120°C

39

METERS

DETAILS

• Digital wall mountable / desktop type warning carbon dioxide level

• Alarm Output Drives Relay to control ventilations system

• Super Large LCD display Air Temp & RH or Dew Point, Wet Bulb CO² Values

• NDIR (Non-Dispersive Infared) Waveguide Technology W/ABC

(Automactic Background Calibaration) Preset On

• Display TWA (Time-weight average) 8 hrs value or 15 min STEL

(Short-term exposure limit) Value

• Long Time Drift Compensation

• Visible / Audible Alarm setting

• Monitoring residential, commercial and light-industrial spaces

• Max. / Min. / Average recall function RS232 output every 2sec

for further anaylsis

• OEM Datalogging function is available temperature unit is switchable.

CO2 WALL MOUNT METERS

WALL MOUNT CARBON DIOXIDE MONITOR 7722 / 77232

SPECIFICATIONS

MEASURING RANGECO², 0~9999ppm

2001~9999ppm (out of scale range)

RESOLUTION 1ppm, 0.1ºC, 0.1ºF,0.1% RH

ACCURACY

• ±50ppm ±5% of reading

(CO²), (0~2000ppm)

• Other range are not specified.

±0.6ºC/ ±0.9ºF, ±3% RH

(at 25ºC, 10~90%)

• Others ±5% for other RH ranges.

RH RANGE 0.0%~99.9%

WARM-UP TIME 30 Seconds

RESPONSE TIME CO²: About 30 seconds

CURRENT CONDITIONS<50mA average

<310mA peak current (-55ms)

OPERATING CONDITIONS 0~50ºC, 0~95% RH (avoid condensation) for CO²

STORAGE CONDITIONS -20~60ºC, 0~99% RH (avoid condensation)

POWER SUPPLY 12VDC Adaptor

METER SIZE 130 x 85 x 60 mm (LxWxT)

STANDARD PACKING INCLUDES Meter, Manual, 100–240VAC, white paper box

OPTIONAL ACCESSORY

RS232 software and cabie,

Salt bottles HR33,

HR75 for callibration purpose.

77232: LOW DRIFT AND HIGH PERFORMANCE

CARBON DIOXIDE MEASUREMENT

RH0~99.9%, others are the same

as 7722

CO² MEASURING

RANGE

0~9999ppm

5001~9999ppm (out of scale range)

ACCURACY

±30ppm ±5% of reading

(0~5000ppm)

Other range accuracy

are not specified

OPERATION

CONDITIONS

0~50ºC, 0~95% RH

(avoid condensation) for CO²

Page 40: CATALOGUE - Sentien Electronicssentien-electronics.com.au/catalogues/SENTIEN_CATALOGUE.pdf · for a better protection between bezel and metal panel. TECHNICAL DATA CONTROL RANGE -50÷120°C

40

METERS

CO2 HAND HELD METERS

DETAILS

• Low Drift Portable Meter checking poor indoor air quality in office

• Dual Display 2 Parameters simultaneously: CO², Temperature

• Big LCD Display with High Resolution

• Design with NDIR (Non-Dispersive Infared) Waveguide Technology High

Performance Low Drift Sensor

• Manual Calibration is recommended

• Warning Carbon Dioxide Level

• Backlight function for working in dark area

• Long time drift compensation

• Audible Alarm Threshold setting

• Max. / Min. / Average functions included

• RS232 output every 2 seconds via software to link to PC for further analysis

• Hold function freezes current readings

• Display TWA (Time-weight average) 8 Hrs value or 15 min STEL

(Short-term exposure limit) Value

• Housing designed surrounds with rails to help air ventilation for

quick and accurate readings

• Easy to calibrate at fresh air around 380~420ppm

HANDY CARBON DIOXIDE / TEMP. HIGH PERFORMANCE 77532

SPECIFICATIONS

MEASURING RANGECO², 0~9999ppm

5001~9999ppm (out of scale range)

Temperature: -10~60ºC, (14~140ºF)

RESOLUTION1ppm, -CO² concentration, 0.1ºC / ºF

Temperature

ACCURACY

• ±30ppm ±5% of reading

(CO²), (0~5000ppm)

• Other range are not specified.

• Temperature: ±0.6% ±0.9ºF

SENSING TECH -NDIR Sensor

WARM-UP TIME 30 Seconds

RESPONSE TIMECO²: About 30 seconds (Once environment changed; for

HI to LO or LO to HI temperature)

ALARM SOUND LEVEL Around 80dB

OPERATING CONDITIONS 0~50ºC, 0~95% RH (avoid condensation)

STORAGE CONDITIONS -20~60ºC, 0~99% RH (avoid condensation)

POWER SUPPLY AA Type (UM-3) x 4pcs

BATTERY LIFE >24hours (Alkaline battery)

STANDARD PACKING INCLUDES Meter, Manual, Batteries and Hard Carrying Case

OPTIONAL ACCESSORY RS232 software and D-Sub Connector VZRRS232M

Page 41: CATALOGUE - Sentien Electronicssentien-electronics.com.au/catalogues/SENTIEN_CATALOGUE.pdf · for a better protection between bezel and metal panel. TECHNICAL DATA CONTROL RANGE -50÷120°C

41

METERS

REFRIGERANT GAUGES

RG-80-4L RG-80-4H

DIAL SIZE 3.15" 3.15"

CONNECTION 1/8 NPT 1/8 NPT

TEMPERATURE °C °C

PRESSURE SCALE 250PSI & 17BAR 500PSI & 35BAR

COLOUR BLUE RED

RG-80-410L RG-80-410H

DIAL SIZE 3.15" 3.15"

CONNECTION 1/8 NPT 1/8 NPT

TEMPERATURE ºF & ºC DUAL ºF & ºC DUAL

PRESSURE SCALE 500PSI & 35BAR 800PSI & 55BAR

COLOUR BLUE RED

LRG-250 LRG-500

DIAL SIZE 2 – 1/2" 2 –1/2"

CONNECTION 1/8 NPT 1/8 NPT

TEMPERATURE °C °C

PRESSURE SCALE 250PSI & 17.5kg/cm² 250PSI & 35kg/cm²

REMARK Stainless Steel Case, Glycerine Filled Scale For R22/R134a/

R404A or R134a/R404A/R407C, Also Available

FRG-250 FRG-500

DIAL SIZE 2 – 1/2" 2 –1/2"

CONNECTION 1/4 SAE 1/4 SAE

TEMPERATURE °C °C

PRESSURE SCALE 210PSI & 15kg/cm² 500PSI & 35kg/cm²

REMARK Black Oxide Flange, A Type: 92mm O.D. of Flange,

B Type: 85mm O.D. of Flange, C Type: 80mm O.D. of Flange,

LFRG-250 LFRG-500

DIAL SIZE 2 –1/2" 2 –1/2"

CONNECTION 1/4 SAE 1/4 SAE

TEMPERATURE °C °C

PRESSURE SCALE 250PSI & 17.5kg/cm² 500PSI & 35kg/cm²

REMARK Stainless Steel Case, Glycerine Filled Scale For R22/R134a/

R404A or R134a/R404A/R407C, Also Available

SCALE: R22, R134A, R404A & R407C

SCALE: R410A SINGLE

SCALE: R12, R22 & R502

SCALE: R22, R134A

SCALE: R12 R2 & R502

REFERENCE IPSI = 0.07kg / cm² = 0.067 BAR = 0.0069 MPA = 6.9kpa

Page 42: CATALOGUE - Sentien Electronicssentien-electronics.com.au/catalogues/SENTIEN_CATALOGUE.pdf · for a better protection between bezel and metal panel. TECHNICAL DATA CONTROL RANGE -50÷120°C

42

3-PHASE MONITOR

PHASE MONITORS

FEATURES

• Low cost, single side 3-phase protection

• Bright LED indications for faults and loads energized

• Easy to install, no adjustments

• Wide operating range: 190-600VAC

• Less than 1 second phase loss response

• Automatic reset from a fault condition

• Compact packaging: fits almost anywhere

• Rugged, epoxy-encapsulation for extreme conditions

• Works great with the ICM450 for load side monitoring

of part winding start and mutiple compressor systems.

SPECIFICATIONS

INPUT/OUTPUT

LINE VOLTAGE 190 – 600VAC

FREQUENCY 50/60 Hz

CONTROL VOLTAGE

• ICM401: 18 – 30VAC

• ICM402: 115 – 230VAC

OUTPUT

• RELAY SPST

• ICM401: N.O. 10 amps

• ICM402: N.O. 30 amps

CASE DIMENSIONS 3"1 x 3.2"w x 1.4"h

MODEL: ICM401

ICM401 WIRING DIAGRAM

ICM401 – MODEL

The ICM401 is low cost 3-phase line monitor that protects against

phase loss, phase reversal and phase unbalance, ideally suited to

protect scroll & screw compressors from reverse rotation.

MODE OF OPERATIONIf all 3 phases are relatively equal and in proper sequence,

the normally open contacts (Y/Y-OUT) will close when 24 volts

is applied between C and Y. If the phases are out of sequence

or one is missing, the contacts will never close.

If a phase is lost while the ICM401 is energized, the contacts will

open immediately, and remain open until the error is corrected.

An illuminated green LED indicates that the output is energized,

and illuminated red LED indicates that there is a fault and the

output is de-energized.

Page 43: CATALOGUE - Sentien Electronicssentien-electronics.com.au/catalogues/SENTIEN_CATALOGUE.pdf · for a better protection between bezel and metal panel. TECHNICAL DATA CONTROL RANGE -50÷120°C

43

3~

R

S

T

4

1

3

211

10

9

5

8

67

POWER MONITOR RELAY

PHASE MONITORS

MOTOR

3~

Coil

R(L1)

S(L2)

T(L3)

4

1

3

2

5

8

6

7

Phase R

Phase S

Phase T

Output (1-4)

Output (1-3)

S

R

T

R

T

S

R

S

T

AC POWER

(1-3)

(1-4)

OVER

UNDER

VOLTAGE MONITOR: JVM-1/JVM-2/JVM-3 /JVM-4

This device for monitoring that the 3 phase power supply all phase

voltage are present and phase sequence is correct.

RATED VOLTAGE 3Φ 220V, 380V, 400V, 415V

OUTPUT CAPACITY 5A

JVM-1, JVM-3

Output relay will be switched to ON (#1 & 3 close)

immediately when power is applied to the unit and detecting

that 3 phase sequence correctly. Otherwise keep it at original

position (#1 & 4 close).

In case of any phase failure or drops below 70% of rated

voltage for 3 seconds the output relay will return to original

position to cut power when it is on normally operation.

JVM-2, JVM-4

(1) Phase sequence monitor

(2) Adjustable setting from ±5% to ±20% of rated voltage,

if the line voltage over or under than setting voltage output

relay keep at original position.

Output relay will be switched to ON (#1.3 connected) when

power is applied to unit and detecting that 3 phases are in

correct sequence and the voltage are in the setting range.

TYPEPHASE

FAILURE

PHASE

SEQUENCEUNDER VOLT OVER VOLT

JVM-1 ∕ ∕

JVM-2 ∕ ∕ ∕

JVM-3 ∕ ∕

JVM-4 ∕ ∕ ∕

JVM-3/JVM-4

JVM-3/JVM-4 OPERATION CHART

JVM-1/JVM-2

JVM-1/JVM-3 OPERATION CHART

MODEL: DIAGRAMS

JVM-1 JVM-2 JVM-3 JVM-4

Page 44: CATALOGUE - Sentien Electronicssentien-electronics.com.au/catalogues/SENTIEN_CATALOGUE.pdf · for a better protection between bezel and metal panel. TECHNICAL DATA CONTROL RANGE -50÷120°C

44

INDICATOR LIGHTS

PILOT LAMPS

NPL22 - G A 1 2 3

1. SERIES

NPL22 Normal (Round Head)

NLD22 Simple (Flush Head)

2. CAP COLOUR

R G W Y S

RED GREEN WHITE YELLOW BLUE

3. VOLTAGE RATING

NPL22A E I

AC.DC.24V AC.DC.100-120V AC.DC.220-240V

NLD22A D E G I M

AC.DC.24V DC.110V AC.100-120V DC.220V AC.220-240V AC.380-440V

MODEL DESIGNATION

NPL22-GA

NPL22-R NLD22-R

NPL22-Y NLD22-Y

NPL22-G NLD22-G

Page 45: CATALOGUE - Sentien Electronicssentien-electronics.com.au/catalogues/SENTIEN_CATALOGUE.pdf · for a better protection between bezel and metal panel. TECHNICAL DATA CONTROL RANGE -50÷120°C

45

INDICATOR LIGHTS

NEON INDICATOR LIGHTS

COLOUR Red, Orange, Green. COLOUR Red, Orange, Green.

COLOUR Red, Orange, Green. COLOUR Red, Orange, Green.

COLOUR Red, Orange, Green. COLOUR Red, Orange, Green.

COLOUR Red, Orange, Green. COLOUR Red, Orange, Green.

COLOUR Red, Orange, Green. COLOUR Red, Orange, Green.

N-013 NEON INDICATOR W/RESISTOR 120V 220V

N-014 NEON INDICATOR W/RESISTOR 120V 220V

N-015 NEON INDICATOR W/RESISTOR 120V 220V

N-016 NEON INDICATOR W/RESISTOR 120V 220V

N-017 NEON INDICATOR W/RESISTOR 120V 220V

N-018 NEON INDICATOR W/RESISTOR 120V 220V

N-019 NEON INDICATOR W/RESISTOR 120V 220V

N-020 NEON INDICATOR W/RESISTOR 120V 220V

N-021 NEON INDICATOR W/RESISTOR 120V 220V

N-022 NEON INDICATOR W/RESISTOR 120V 220V

N-023 NEON INDICATOR W/RESISTOR 120V 220V

N-024 NEON INDICATOR W/RESISTOR 120V 220V

N-022P PILOT INDICATOR LIGHT 6V 12V 24V

(WITH WIRE)

(WITH WIRE)N-018P PILOT INDICATOR LIGHT 6V 12V 24V

COLOUR Red, Orange, Green. COLOUR Red, Orange, Green.

Page 46: CATALOGUE - Sentien Electronicssentien-electronics.com.au/catalogues/SENTIEN_CATALOGUE.pdf · for a better protection between bezel and metal panel. TECHNICAL DATA CONTROL RANGE -50÷120°C

46

INDICATOR LIGHTS

INDICATOR LIGHTS

N-701P PILOT INIDCATOR LIGHT 6V 12V 24V

N-701L LED INDICATOR LIGHT W/RESISTOR 6V 12V 24V

COLOUR Red, Yellow and Green are Available for Each Part.

L-601 LED INDICATOR LIGHT WO/RESISTOR 2V

L-602 LED INDICATOR LIGHT WO/RESISTOR 2V

L-603 LED INDICATOR LIGHT WO/RESISTOR 2V

L-605 LED INDICATOR LIGHT WO/RESISTOR 2V

L-606 LED INDICATOR LIGHT WO/RESISTOR 2V

L-607 LED INDICATOR LIGHT WO/RESISTOR 2V

L-608 LED INDICATOR LIGHT WO/RESISTOR 2V

L-609 LED INDICATOR LIGHT WO/RESISTOR 2V

L-610 LED INDICATOR LIGHT WO/RESISTOR 2V

L-612 LED INDICATOR LIGHT WO/RESISTOR 2V

L-613 LED INDICATOR LIGHT WO/RESISTOR 2V

N-701 LED INDICATOR LIGHT W/RESISTOR 2V

N-022P PILOT INDICATOR LIGHT 6V 12V 24V

Page 47: CATALOGUE - Sentien Electronicssentien-electronics.com.au/catalogues/SENTIEN_CATALOGUE.pdf · for a better protection between bezel and metal panel. TECHNICAL DATA CONTROL RANGE -50÷120°C

47

INDICATOR LIGHTS

INIDCATOR LIGHTS

N-702 NEON INDICATOR LIGHT WO/RESISTOR

N-703 NEON INDICATOR LIGHT W/RESISTOR 120V 220V

N-704 NEON INDICATOR LIGHT WO/RESISTOR (N/R) 120V 220V

N-705 NEON INDICATOR LIGHT W/RESISTOR 120V 220V

N-706 NEON INDICATOR LIGHT WO/RESISTOR (N/R) 120V 220V

N-707 PILOT INDICATOR LIGHT 6V 12V 24V

N-708L LED INDICATOR LIGHT W/RESISTOR 6V 12V 24V 120V 220V

N-801 NEON INDICATOR LIGHT W/RESISTOR 120V 220V

N-802 NEON INDICATOR LIGHT W/RESISTOR 120V 220V

N-803 NEON INDICATOR LIGHT W/RESISTOR 120V 220V

N-804 NEON INDICATOR LIGHT W/RESISTOR 120V 220V

N-804A NEON INDICATOR LIGHT W/RESISTOR 120V 220V

N-803P PILOT INDICATOR LIGHT 6V 12V 24VN-705L LED INDICATOR LIGHT W/RESISTOR 6V 12V 24V

N-705P PILOT INDICATOR LIGHT 6V 12V 24V

N-804AP PILOT INDICATOR LIGHT 6V 12V 24V

N-802P PILOT INDICATOR LIGHT 6V 12V 24VN-704L LED INDICATOR LIGHT W/RESISTOR 6V 12V 24V

N-704P PILOT INDICATOR LIGHT 6V 12V 24V

N-804P PILOT INDICATOR LIGHT 6V 12V 24VN-706L LED INDICATOR LIGHT W/RESISTOR 6V 12V 24V

N-706P PILOT INDICATOR LIGHT 6V 12V 24V

N-801P PILOT INDICATOR LIGHT 6V 12V 24V

N-702L LED INDICATOR LIGHT W/RESISTOR 6V 12V 24V

N-702P PILOT INDICATOR LIGHT 6V 12V 24V

COLOUR Red, Yellow and Green are Available for Each Part.

N-703L LED INDICATOR LIGHT W/RESISTOR 6V 12V 24V

N-703P PILOT INDICATOR LIGHT 6V 12V 24V

Page 48: CATALOGUE - Sentien Electronicssentien-electronics.com.au/catalogues/SENTIEN_CATALOGUE.pdf · for a better protection between bezel and metal panel. TECHNICAL DATA CONTROL RANGE -50÷120°C

48

INDICATOR LIGHTS

INDICATOR LIGHTS

N-805 NEON INDICATOR LIGHT W/RESISTOR 120V 220V

N-806 NEON INDICATOR LIGHT W/RESISTOR 120V 220V

N-807 NEON INDICATOR LIGHT W/RESISTOR 120V 220V

N-808 NEON INDICATOR LIGHT W/RESISTOR 120V 220V

N-809 NEON INDICATOR LIGHT W/RESISTOR 120V 220V

N-810 NEON INDICATOR LIGHT W/RESISTOR 120V 220V

N-811 NEON INDICATOR LIGHT W/RESISTOR 120V 220V

N-812 NEON INDICATOR LIGHT W/RESISTOR 120V 220V

N-813 NEON INDICATOR LIGHT W/RESISTOR 120V 220V

N-814 NEON INDICATOR LIGHT W/RESISTOR 120V 220V

N-815 NEON INDICATOR LIGHT W/RESISTOR 120V 220V

N-816 NEON INDICATOR LIGHT W/RESISTOR 120V 220V

N-814L LED INDICATOR LIGHT W/RESISTOR 6V 12V 24V

N-814P PILOT INDICATOR LIGHT 6V 12V 24V

N-808P PILOT INDICATOR LIGHT 6V 12V 24V

N-816P PILOT INDICATOR LIGHT 6V 12V 24V

N-816L RED INDICATOR LIGHT W/RESISTOR 6V 12V 24V

N-813P PILOT INDICATOR LIGHT 6V 12V 24VN-807P PILOT INDICATOR LIGHT 6V 12V 24V

N-815L LED INDICATOR LIGHT W/RESISTOR 6V 12V 24V

N-815P PILOT INDICATOR LIGHT 6V 12V 24V

N-809P PILOT INDICATOR LIGHT 6V 12V 24V

N-812P PILOT INDICATOR LIGHT 6V 12V 24V

N-811P PILOT INDICATOR LIGHT 6V 12V 24VN-805P PILOT INDICATOR LIGHT 6V 12V 24V

N-810P PILOT INDICATOR LIGHT 6V 12V 24V

COLOUR Red, Yellow and Green are Available for Each Part.

N-806P PILOT INDICATOR LIGHT 6V 12V 24V

Page 49: CATALOGUE - Sentien Electronicssentien-electronics.com.au/catalogues/SENTIEN_CATALOGUE.pdf · for a better protection between bezel and metal panel. TECHNICAL DATA CONTROL RANGE -50÷120°C

49

INDICATOR LIGHTS

N-827 NEON INDICATOR LIGHT W/RESISTOR (NR)

N-828 NEON INDICATOR LIGHT W/RESISTOR (NR) 120V 220V

N-828B NEON INDICATOR LIGHT W/RESISTOR 120V 220V

N-830 NEON INDICATOR LIGHT W/RESISTOR 120V 220V

N-831 E-10 SCREW BASE INDICATOR LIGHT HOLDER

N-832 E-10 SCREW BASE INDICATOR LIGHT HOLDER

N-833 SIZE: 30M/M, 20M/M

N-835W NEON INDICATOR LIGHT W/RESISTOR 120V 220V

N-3001 NEON INDICATOR LIGHT W/RESISTOR 120V 220V

N-3002 E-10 S-9 6V 12V 24V 120V 220V

R-2001 4P 6P

R-2002A

COLOUR Red, Yellow and Green are Available for Each Part.

E-5 6V 12V 24VN-830P PILOT INDICATOR LIGHT 6V 12V 24V

5-9 BAYONET BASE INDICATOR LIGHT HOLDER

N-827P PILOT INDICATOR LIGHT 6V 12V 24V

N-828L LED INDICATOR LIGHT W/RESISTOR 6V 12V 24V

N-828P PILOT INDICATOR LIGHT 6V 12V 24V

Page 50: CATALOGUE - Sentien Electronicssentien-electronics.com.au/catalogues/SENTIEN_CATALOGUE.pdf · for a better protection between bezel and metal panel. TECHNICAL DATA CONTROL RANGE -50÷120°C

50

SWITCHING POWER SUPPLY – SINGLE OUTPUT

POWER SUPPLIES

MODEL NO. OUTPUT TOL. R & N EFFI.

S-15-5 5V, 0~3.0A ± 2% 50mV 65%

S-15-12 12V, 0~1.3A ± 1% 50mV 68%

S-15-24 24V, 0~0.7A ± 1% 50mV 73%

MODEL NO. OUTPUT TOL. R & N EFFI.

S-35-5 5V, 0~7.0A ± 2% 75mV 70%

S-35-12 12V, 0~3.0A ± 1% 100mV 76%

S-35-15 15V, 0~2.4A ± 1% 100mV 78%

S-35-24 24V, 0~1.5A ± 1% 100mV 78%

• Low Cost, High Reliability

• AC Input Range selectable

by switch

• Protections: Short

Circuit / Over load

• Cooling by free air convection

• 100% full load burn-in test

• 1 Year Warranty

• Universal AC input / Full Range

• Protections: Short Circuit,

Overload, Over Voltage

• Cooling by free air convection

• Approvals: UL/CUL/TUB/CB/Ce

• Fixed switching frequency

at 50Khz

• 100% full load burn-in test

DETAILS

AC INPUT VOLTAGE RANGE 85~132VAC / 170~264VAC selected by sw.

AC INRUSH CURRENT Cold Start, 15A / 115VAC, 30A / 230VAC

DC ADJUSTMENT RANGE ±10% of rated output Voltage

OVERLOAD PROTECTION 105%~150% fold back limiting, auto-recovery

SETUP, RISE, HOLD UP TIME 200ms, 100ms, 20ms at full load & 230VAC

WITHSTAND VOLTAGE I/P-0/P: 1.5KVAC, I/P-FG: 1.5KVAC, 1min.

WORKING TEMP 0~50°C @ 100%, -10°C @ 80%, 60°C @ 60%

SAFETY STANDARDS Design refer to UL 1012 Requirement

EMC STANDARDS Design refer to FCC part 15J

CONNECTION 5P / 9.5mm pitch terminal block

DETAILS

AC INPUT VOLTAGE RANGE 85~264VAC / 120~370VAC

AC INRUSH CURRENT Cold Start, 30A at 115VAC, 60A at 230VAC

DC ADJUSTMENT RANGE ±10% of rated output Voltage

OVERLOAD PROTECTION 105%~150% hiccup mode, auto-recovery

OVER VOLTAGE PROTECTION 115%~135% of rated output voltage

SETUP, RISE, HOLD UP TIME 300ms, 50ms, 80ms at full load & 230VAC

WITHSTAND VOLTAGE I/P-0/P: 3KVAC, I/P-FG: 1.5KVAC, 1min.

WORKING TEMP 0~45°C @ 100%, -10°C @ 80%, 60°C @ 60%

SAFETY STANDARDS UL 1012, UL1950, TUV EN60950 approved

SAFETY STANDARDSEN55022 class B, EN61000-3-2-3

EN61000-4-2, 3, 4, 5, 6, 8, 11, ENV50204

EMC STANDARDS 5P/9.5mm pitch terminal block

CONNECTION 5P / 9.5mm pitch terminal block

DETAILS

AC INPUT VOLTAGE RANGE 85~132VAC / 170~264VAC selected by sw.

AC INRUSH CURRENT Cold Start, 15A / 115VAC, 30A / 230VAC

DC ADJUSTMENT RANGE (FOR 15W) Cold Start, 18A at 115VAC, 36A at 230VAC

DC ADJUSTMENT RANGE (FOR 35W) ±10% of rated output Voltage

OVERLOAD PROTECTION 105%~150% fold back limiting, auto-recovery

SETUP, RISE, HOLD UP TIME 200ms, 100ms, 30ms at full load & 230VAC

WITHSTAND VOLTAGE I/P-0/P: 1.5KVAC, I/P-FG: 1.5KVAC, 1min.

WORKING TEMP 0~50°C @ 100%, -10°C @ 80%, 60°C @ 60%

SAFETY STANDARDS Design refer to UL 1012 Requirement

EMC STANDARDS Design refer to FCC part 15J

CONNECTION 5P / 9.5mm pitch terminal block

MODEL NO. OUTPUT TOL. R & N EFFI.

S-50-5 5V, 0~10A ± 2% 75mV 71%

S-50-12 12V, 0~4.2A ± 1% 100mV 78%

S-50-15 15V, 0~3.4A ± 1% 100mV 78%

S-50-24 24V, 0~2.1A ± 1% 100mV 82%

MODEL NO. OUTPUT TOL. R & N EFFI.

S-60-5 5V, 0~20A ± 2% 120mV 74%

S-60-12 12V, 0~5.0A ± 1% 120mV 77%

S-60-15 15V, 0~4.0A ± 1% 150mV 78%

S-60-24 24V, 0~2.5A ± 1% 150mV 81%

15W

CASE 90599x97x35mm0.31kgs

35W

CASE 903129x98x38mm0.4kgs

50W

CASE 90199x97x35mm0.39kgs

60W

CASE 901159x97x38mm0.55kgs

Page 51: CATALOGUE - Sentien Electronicssentien-electronics.com.au/catalogues/SENTIEN_CATALOGUE.pdf · for a better protection between bezel and metal panel. TECHNICAL DATA CONTROL RANGE -50÷120°C

51

POWER SUPPLIES

DETAILS

AC INPUT VOLTAGE RANGE 85~264VAC / 120~370VAC

AC INRUSH CURRENT (FOR 25W) Cold Start, 15A / 115VAC, 30A / 230VAC

AC INRUSH CURRENT (FOR 40W) Cold Start, 30A at 115VAC, 60A at 230VAC

DC ADJUSTMENT RANGE ±10% of rated output Voltage

OVERLOAD PROTECTION 105%~150% hiccup mode, auto-recovery

OVER VOLTAGE PROTECTION 115%~135% of rated output voltage

SETUP, RISE, HOLD UP TIME 300ms, 50ms, 80ms at full load & 230VAC

SETUP, RISE, HOLD UP TIME (FOR 40W) 300ms, 50ms, 60ms at full load & 230VAC

WITHSTAND VOLTAGE I/P-0/P: 3KVAC, I/P-FG: 1.5KVAC, 1min.

WORKING TEMP 0~50°C @ 100%, -10°C @ 80%, 60°C @ 60%

SAFETY STANDARDS UL 1012, TUV EN60950 approved

EMC STANDARDS EN55022 class B, EN61000-3-2,3,EN6100-4-2,3,4,5

CONNECTION 5P / 9.5mm pitch terminal block

MODEL NO. OUTPUT TOL. R & N EFFI.

S-25-5 5V, 0~5.0A ± 2% 50mV 72%

S-25-12 12V, 0~2.1A ± 1% 100mV 76%

S-25-15 15V, 0~1.7A ± 1% 100mV 77%

S-25-24 24V, 0~1.1A ± 1% 100mV 80%

MODEL NO. OUTPUT TOL. R & N EFFI.

S-100-3 3V, 0~20A ± 2% 50mV 70%

S-100-5 5V, 0~20A ± 2% 100mV 78%

S-100-7.5 7.5V, 0~13.6A ± 1% 100mV 80%

S-100-10 10V, 0~10A ± 1% 100mV 80%

S-100-12 12V, 0~8.5A ± 1% 100mV 81%

S-100-15 15V, 0~6.7A ± 1% 100mV 81%

S-100-18 18V, 0~5.6A ± 1% 100mV 82%

S-100-24 24V, 0~4.5A ± 1% 100mV 84%

S-100-27 27V, 0~3.7A ± 1% 100mV 84%

S-100-48 48V, 0~2.0A ± 1% 100mV 84%

MODEL NO. OUTPUT TOL. R & N EFFI.

S-40-5 5V, 0~8.0A ± 2% 75mV 72%

S-40-12 12V, 0~3.5A ± 1% 100mV 76%

S-40-15 15V, 0~2.8A ± 1% 100mV 76%

S-40-24 24V, 0~1.8A ± 1% 100mV 78%

• Low Cost, High Reliability

for S-100

• UL/TUV/CB/CE for S-100F

• AC input range selectable

by switch

• Protections: Short Circuit/

Overload/ Over Voltage

• Cooling by free air convention

• Fixed switching frequency

at 25KHz for S-100 and

83KHz for S-100-F

DETAILS

AC INPUT VOLTAGE RANGE 85~132VAC / 170~264VAC selected by sw.

AC INRUSH CURRENT Cold Start, 20A / 115VAC, 40A / 230VAC

DC ADJUSTMENT RANGE ±10% of rated output Voltage

OVERLOAD PROTECTION 105%~150% hiccup mode auto-recovery

SETUP, RISE, HOLD UP TIME 200ms, 80ms, 20ms at full load & 230VAC

WITHSTAND VOLTAGE I/P-0/P: 1.5KVAC, I/P-FG: 1.5KVAC, 1min.

WORKING TEMP0~50°C @ 100%, -10°C @ 80%, 60°C @ 60%

(5V & 7.5V: 0~45°C @ 100%, 60°C @ 50% load)

SAFETY & EMC STANDARDS Design refer to UL 1012 & FFC part 15J

CONNECTION 7P / 9.5mm pitch terminal block

DETAILS

AC INPUT VOLTAGE RANGE 88~132VAC / 170~264VAC selected by sw.

AC INRUSH CURRENT Cold Start, 30A / 115VAC, 60A / 230VAC

DC ADJUSTMENT RANGE 10% of rated output Voltage

OVERLOAD PROTECTION 105%~150% hiccup mode auto-recovery

OVER VOLTAGE PROTECTION 1000ms, 30ms, 15ms, at full load and 230VAC

SETUP, RISE, HOLD UP TIME 200ms, 80ms, 20ms at full load & 230VAC

WITHSTAND VOLTAGE I/P-0/P: 3KVAC, I/P-FG: 1.5KVAC, 1min.

WORKING TEMP 0~50°C @ 100%, -10°C @ 80%, 60°C @ 60%

SAFETY & EMC STANDARDSEN55022 class B EN61000-3-2-3

EN61000-4-2, 3, 4, 5, 6, 8, 11, EENV50204

CONNECTION 7P / 9.5mm pitch terminal block

25W

CASE 90599x97x35mm0.39kgs

40W

CASE 903129x98x38mm0.44kgs

100W

CASE 902199x98x38mm0.65kgs

MODEL NO. OUTPUT TOL. R & N EFFI.

S-100-5 5V, 0~20A ± 2% 100mV 76%

S-100-7.5 7.5V, 0~13.5A ± 1% 125mV 78%

S-100-12 12V, 0~8.5A ± 1% 125mV 80%

S-100-15 15V, 0~6.7A ± 1% 125mV 81%

S-100-24 24V, 0~4.5A ± 1% 150mV 83%

S-100-48 48V, 0~2.2A ± 1% 150mV 84%

Page 52: CATALOGUE - Sentien Electronicssentien-electronics.com.au/catalogues/SENTIEN_CATALOGUE.pdf · for a better protection between bezel and metal panel. TECHNICAL DATA CONTROL RANGE -50÷120°C

52

POWER SUPPLIES

SINGLE OUTPUT SWITCHING POWER SUPPLIES

CASE 926A 247 x 127 x 63.5mm

• AC input range selectable by switch

• Protections: Short circuit / Overload / Over voltage / Over temp.

• Built in remote sense function

• High power density 4.9 W/in³

• Forced air cooling by built-in DC fan

• Approvals: UL / CUL

• 100% full load burn-in test

• Low cost, high reliability

• 2 year warranty

CASE 935B 248 x 127 x 63.5mm

• AC input range selectable by switch

• Protections: Short circuit / Overload / Over voltage / Over temp.

• Built in remote sense function

• High power density 4.9 W/in³

• Forced air cooling by built-in DC fan

• Approvals: UL / CUL

• 100% full load burn-in test

• Low cost, high reliability

• 2 year warranty

DETAILS

AC INPUT VOLTAGE

RANGE

90~132VAC / 180~264VAC selectable

by switch

AC INRUSH CURRENT Cold start, 25A at 115VAC, 50A at 230VAC

DC ADJUSTMENT RANGE ±10% rated output voltage

OVERLOAD PROTECTION 105%~125% shut off, AC recycle to re-start

OVER VOLTAGE

PROTECTION 115%~140% rated output voltage

SETUP, RISE, HOLD UP

TIME 1000ms, 50ms, 20ms at full load and 230VAC

WITHSTAND VOLTAGE I / P-O / P:3KVAC, I / P-FG: 1/ 5KVAC, 1minute

WORKING TEMPERATURE -20+40°C@100%, 60°C@60% load

SAFETY STANDARDS UL60950-1 Approved

EMC STANDARDS Design refer to EN55022 class B

CONNECTION3 / P10mm, 6P / 13mm pitch terminal block with

cover

PACKING 2.1kg ; 6pcs / 13.4pg / 1.2CUFT

DETAILS

AC INPUT VOLTAGE

RANGE

90~132VAC / 180~264VAC selectable

by switch

AC INRUSH CURRENT Cold start, 25A at 115VAC, 50A at 230VAC

DC ADJUSTMENT RANGE ±10% rated output voltage

OVERLOAD PROTECTION 105%~125% shut off, AC recycle to re-start

OVER VOLTAGE

PROTECTION 115%~140% rated output voltage

SETUP, RISE, HOLD UP

TIME 1000ms, 50ms, 20ms at full load and 230VAC

WITHSTAND VOLTAGE I / P-O / P:3KVAC, I / P-FG: 1/ 5KVAC, 1minute

WORKING TEMPERATURE -20+40°C@100%, 60°C@60% load

SAFETY STANDARDS UL60950-1 Approved

EMC STANDARDS Design refer to EN55022 class B

CONNECTION3 / P10mm, 6P / 13mm pitch terminal block with

cover

PACKING 2.1kg ; 6pcs / 13.4pg / 1.2CUFT

STOCK NO. MODEL NO. OUTPUT TOL. R & N EFFI.

11421 SE-1000-5 5V, 0~150A ± 1% 150mV 81%

11422 SE-1000-9 9V, 0~100A ± 1% 150mV 84%

11423 SE-1000-12 12V, 0~83.3A ± 1% 150mV 85%

11424 SE-1000-15 15V, 0~66.7A ± 1% 150mV 86%

11425 SE-1000-24 24V, 0~41.7A ± 1% 200mV 88%

11426 SE-1000-48 48V, 0~20.8A ± 1% 200mV 89%

STOCK NO. MODEL NO. OUTPUT TOL. R & N EFFI.

10661 SE-600-5 5V, 0~100A ± 2% 150mV 78%

10662 SE-600-12 12V, 0~50A ± 1% 150mV 83%

10663 SE-600-15 15V, 0~40A ± 1% 150mV 84%

10664 SE-600-24 24V, 0~25A ± 1% 150mV 87%

10665 SE-600-27 27V, 0~22.2A ± 1% 150mV 87%

10666 SE-600-48 48V, 0~12.5A ± 1% 200mV 88%

600W MODEL 1000W MODEL

Page 53: CATALOGUE - Sentien Electronicssentien-electronics.com.au/catalogues/SENTIEN_CATALOGUE.pdf · for a better protection between bezel and metal panel. TECHNICAL DATA CONTROL RANGE -50÷120°C

53

SOLLATEK VOLTAGE STABILISER (SVS)Over and under Voltage Proctection

RATED VOLTAGE

• High Voltage

• Low Voltage

• Spikes / Surges

• Power-back surges

REGULATORS / STABILISERS

VOLTAGE STABILISERS

STANDARD RANGE

STABILISERS (also known as regulators)

stabilise the incoming power supply

providing constant voltage to the equiptment.

Sollatek manufactures two different ranges

of stabilisers. The SVS (Sollatek Voltage

Stabilisers) Range and the AVR (Automatic

Voltage Regulators) Range.

The following table opposite is a brief

comparision between the two ranges.

AVR SVS

CONTROL Microprocessor Microprocessor

SWITCHING Taps / Traics Taps / Relays

SPEED OF CORRECTION 1250V / S 750V / S

INPUT RANGE -30% to + 22% -26% to + 19%

OUTPUT ACCURACY + / -4% + / -6%

AVS FUNCTION

No

Yes. (Dissconnects the mains supply if

the input varies outside pre-set limits

and reconnects automatically.

For a 230V system these are

below 145V or above 290V)

WEIGHT (OF A 2AMP UNIT) About 5Kg About 2Kg

SUITABLE FOR All electrical and electronic equipment.

However if the price doesn't justify it then

use with only sensitive equipment. Like HI-FI,

Video, TV, Lab equipment, etc.

All electrical and electronic equipment.

If wider input and more accurate output

control is desired then use the AVR.

THE SOLLATEK SVS monitors the mains voltage continuously. If the voltage rises or drops,

the SVS will stabilise the output to ensure the voltage reaching your eqipment remains

constant at 230V (+/-6%), within the operating range of the unit. If the input voltage fallas

below 142V or rises above 295V, the SVS will disconnect the output, thereby protecting the

load. Once the mains voltage returns again witnin acceptable limits, the SVS will reconnect

the output following a start up delay. (* All above voltages are for a 220V/230V system.

For other voltages contact your dealer).

PROTECTION

• Microprocessor Controlled Stabiliser • Extremely fast response

• Very wide input voltage range • 10 second start-up delay as standard

• Excellent output voltage stability (+/-6%) • Includes surge and spike suppression

• Incorporates over-voltage & under • Full RFI & noise suppression

voltage disconnect (ER option only)

SINGLE PHASE - UP TO 15 AMPS

MODEL AMPS VA@240V SOCKET AVAILABILITY WEIGHT DIMS

SVS01-22 1 240 UK FR SCH UK5 1.5 193 x 100 x 124

SVS02-22 2 480 UK FR SCH UK5 2.0 193 x 100 x 124

SVS04-22 4 960 UK FR SCH UK5 3.0 193 x 100 x 124

SVS06-22 6 1440 UK FR SCH UK15 4.0 277 x 133 x 161

SVS08-22 8 1920 UK FR SCH UK15 5.0 277 x 133 x 161

SVS12-22 12 2880 UK FR SCH UK15 7.0 277 x 133 x 161

SVS15-22 15 3600 FR SCH UK15 8.0 277 x 133 x 161

STABILISERS

THE SVS PRINCIPLE

Page 54: CATALOGUE - Sentien Electronicssentien-electronics.com.au/catalogues/SENTIEN_CATALOGUE.pdf · for a better protection between bezel and metal panel. TECHNICAL DATA CONTROL RANGE -50÷120°C

54

W5

Type W5

Control

SP Single-Phase Angle Control

SZ Singe-Phase Zero Crossing Control

TP 3-Wire 3-Phase Angle Control

TZ 2-Wire 3-Phase Zero Crossing Control

ZZ 3-Wire 3-Phase Zero Crossing Control

1V – 110VAC (Only for Single-Phase Power Source)4v – 200 ~ 480VAC

Auxiliary PowerSource Code1 – 1φ 110VAC2 – 1φ 220VAC

Normal Rated Current030 – 30A045 – 45A060 – 60A080 – 80A100 – 100A125 – 125A150 – 150A180 – 180A230 – 230A300 – 300A380 – 380A450 – 450A580 – 580A720 – 720A

030 -2 4 J4VTP

0 – 0~5VDC1 – 1~5VDC2 – 2~10VDC3 – 0~10VDC4 – 4~20mA5 – 0~20mAM – Manual Adjustment* – Special

C – Buffering Time 2 Seconds (Zero-Crossing Type Product)J – Adjustable Buffering Time, 1~22 Secs (Phase-Angle Type Product)

– Standard Type (Fixed Resistance load, Inductive Load or LR Light Bulb)TF – Inductive Reactance Type LoadingCL – Limited Current Type (+ Additional Charges)CV – Fixed Voltage Type (+ Additional Charges)

NOTE

W5-Series has no included potentiometer (VR), the VR parts are

option as following part numbers.

1) Part No. Scale/0~100% (Sticker for Scale Range 0~100%)

2) Part No. KB-RN99D (Knob)

3) Part No. VR-RV24YN-20S/B103 (TOCOS Potentiometer 24Ø 10KΩ)

THYRISTOR POWER REGULATOR

SCR POWER CONTROLLERS

W5 – SERIES

W5TP4V030-24J

DESCRIPTION OF THE CONNECTORS

SP · SZ · TZ TP · ZZDESCRIPTION NOTES

CONNECTOR NO. CONNECTOR NO.

F5 Detection of the fuse burn downThe Connection from power to loading mUst be

connected back to the FS Side

• Empty Do Not Connect

M M + 5VDCOnly for this control board, not for other use Positive

Control Signal Input

+ + Positive Control Signal Input The Default Setting is 4 ~ 20mA when

the Sticker is not marked– – Standard Analog Signal Voltage

E3 E3Connected to the VR 3rd pin of the

Outside Potentiometer Adjustable Output 0 ~ 100%, Please eliminate the

shorted Copper Wire between E3 and E2 when using

the Outside Potentiometer with

(2 ~ 10KΩ)

E2 E2Connected to the VR 2nd pin of the

Outside Potentiometer

E1 E1Connected to the VR 1st pin of the

Outside Potentiometer

NC NC Alarm Connector Output (Normal Close) Connector Capacity : 227VAC/2A

125VAC/2A

30VAC/2A

COM COM Alarm Connector Output (Common Point)

NO NO Alarm Connector Output (Normal Open)

AC1 AC1Auxiliary Power Source

Please refer to the stick for the auxiliary

power and voltageAC2 AC2

Page 55: CATALOGUE - Sentien Electronicssentien-electronics.com.au/catalogues/SENTIEN_CATALOGUE.pdf · for a better protection between bezel and metal panel. TECHNICAL DATA CONTROL RANGE -50÷120°C

55

RELAYS

SCL/SCL-1 RELAYS

FEATURES

• Epoxy sealed type and flux free.

• Multiple choice with Lamp, Stud, Diode,

Flashed contact, and Flange cover.

• Contact rating up to 12A/250VAC (DPNO).

• High Reliability/Long life expectancy.

• Socket and PCB terminal available.

ORDERING INFORMATION

CONTACT RATING

LOAD TYPE DPDT DPNO

RESISTIVE LOAD 10A/28VDC 10A/28VDC

MOTOR (UL CSA ONLY) 1/2 HP 250VAC, 1/3 HP 125VAC 1/2 HP 250VAC, 1/3 HP 125VAC

GEN, USE 10A/240VAC 15A/240VAC (UL CSA Only)

SCL

Type SCL Series

Terminal TypeBlank: Socket Terminal1: P C B Terminal

Coil Voltage

Cover TypeBlank: Straight CoverC1: Flange CoverS: Sealed Type

DPDT: Double Pole Doble ThrowDPNT: Double Pole Normally Open

Optional:Blank: Standard TypeL: With Lamp D: With DiodeG: With Stud M: With Manual Button

-1 -L -DPNO -C 220VAC

COIL DATA SCL (DC)

RATED VOLTAGE

(V)

RATED CURRENT

± 10% AT 25°C

(MA)

COIL RESISTANCE

± 10% AT 25°C

(Ω)

MAX.

CONTINUOUS

VOLTAGE AT 25°C

PICK UP VOLTAGE

(MAX) AT 25°C

DROP OUT

VOLTAGE (MIN)

AT 25°C

POWER

CONSUMPTION AT

RATED VOLTAGE

6 150 40

110% Of

Rated Voltage

75% Of

Rated Voltage

10% Of

Rated VoltageApprox. 0.9W

12 75 160

15 60 250

24 37 650

48 19 2600

60 15 4000

110 10 11000

120 11 11000

COIL DATA SCL (AC)

RATED VOLTAGE (V) COIL RESISTANCE

± 10% AT 25°C

(Ω)

MAX. CONTINUOUS

VOLTAGE AT 25°C

PICK UP VOLTAGE

(MAX) AT 25°C

DROP OUT VOLTAGE

(MIN) AT 25°C

POWER

CONSUMPTION AT

RATED VOLTAGE

12 40

110% Of

Rated Voltage

85% Of

Rated Voltage

30% Of

Rated VoltageApprox. 1.2VA

24 160

110 3400

115 3400

120 3400

220 13600

230 13600

240 13600

Page 56: CATALOGUE - Sentien Electronicssentien-electronics.com.au/catalogues/SENTIEN_CATALOGUE.pdf · for a better protection between bezel and metal panel. TECHNICAL DATA CONTROL RANGE -50÷120°C

56

RELAYS

SCLB/SCLD RELAYS

FEATURES

• Miniature size from 2 pole to 4 pole.

• AC & DC Coil.

• Epoxy sealed type and flux free.

• High reliability/Long life expectancy.

• Multiple choice with Lamp, Stud, Diode,

Flashed contact, and Flange cover.

ORDERING INFORMATION

CONTACT RATING

LOAD TYPE SCLB SCLD

RESISTIVE LOAD 5A/28VDC 5A/28VDC

GEN, USE 5A/240VAC 5A/250VAC

SCL

Type SCL Series

Terminal TypeW: Soldered Lug TerminalP: P C B Terminal

Blank: Standard TypeB: Reinforce Barner

B: 2P D:4P

Coil Voltage

Cover TypeC: Straight CoverC1: Flanged CoverS: Seaded Type

Contact FormDPDT: Double Pole Double Throw4PDT: Four Pole Double Throw

Optional:Blank: Standard TypeL: With Lamp D: With DiodeG: With Stud M: With Manual ButtonF: Ag Contact With Au Plating

-P -L -DPDT -C 220VAC-BB

COIL DATA SCL (DC)

RATED VOLTAGE

(V)

RATED CURRENT

± 10% AT 25°C

(MA)

COIL RESISTANCE

± 10% AT 25°C

(Ω)

MAX.

CONTINUOUS

VOLTAGE AT 25°C

PICK UP VOLTAGE

(MAX) AT 25°C

DROP OUT

VOLTAGE (MIN)

AT 25°C

POWER

CONSUMPTION AT

RATED VOLTAGE

6 150 40

110% Of

Rated Voltage

75% Of

Rated Voltage

10% Of

Rated VoltageApprox. 0.9W

12 75 160

15 60 250

24 37 650

48 19 2600

60 15 4000

110 10 11000

120 11 11000

COIL DATA SCL (AC)

RATED VOLTAGE (V) COIL RESISTANCE

± 10% AT 25°C

(Ω)

MAX. CONTINUOUS

VOLTAGE AT 25°C

PICK UP VOLTAGE

(MAX) AT 25°C

DROP OUT VOLTAGE

(MIN) AT 25°C

POWER

CONSUMPTION AT

RATED VOLTAGE

12 40

110% Of

Rated Voltage

85% Of

Rated Voltage

30% Of

Rated VoltageApprox. 1.2VA

24 160

110 3400

120 3400

220 13600

240 13600

Page 57: CATALOGUE - Sentien Electronicssentien-electronics.com.au/catalogues/SENTIEN_CATALOGUE.pdf · for a better protection between bezel and metal panel. TECHNICAL DATA CONTROL RANGE -50÷120°C

57

RELAYS

737 RELAYS

FEATURES

• Multiple enclosure style.

• Indicator Lamp and push-to-test

button option available.

• Plug-in version or PCB terminals.

• High rating 30A 300VAC/28VDC, 15A

600VAC. General Purpose Power relays.

• Available HP ratings 1 HP 120VAC, 1.5 HP

200-600V.

ORDERING INFORMATION

CONTACT RATING

RESISTIVE LOAD 30A/300VAC, 30A/28VDC, 15A/600VAC

MOTOR 1 HP 120VAC, 1.5 HP 200-600VAC

737

Type 737

Contact Form

1X: Single Pole Double Make

1Y: Single Pole Double Break

1Z: Single Pole Double Make/Break

Enclosure StyleBlank: Open TypeC: Plastiv Dust CoverC1: Mounting Ears on CoverC2: Accessible mounting hole with Antirotation TabC3: Mounting Ears on top of Cover

Coil Voltage

OptionalBlank: No Special FeatureL: Provided LampM: Push ButtonT:: PCB Terminal

LMT 12VDC-C1-1X

COIL DATA SCL (AC)

RATED VOLTAGE (V) RATED CURRENT

± 10% AT 25°C

(MA)

COIL RESISTANCE

± 10% AT 25°C

(Ω)

MAX.

CONTINUOUS

VOLTAGE AT 25°C

PICK UP VOLTAGE

(MAX) AT 25°C

DROP OUT VOLTAGE

(MIN) AT 25°C

POWER

CONSUMPTION AT

RATED VOLTAGE

1X

1Y

6 188 32

110% Of

Rated Voltage

80% Of

Rated Voltage

10% Of

Rated VoltageApprox. 1.5W

12 100 120

24 51 472

48 27 1800

110 11 10000

125 12.5 10000

1Z

6 250 24

12 125 96

24 63 384

48 31 1536

110 11.5 9600

125 13 9600

COIL DATA 737 (AC)

Rated Voltage (V) Coil Resistance

± 10% at 25°C (Ω)

Max. Continuous

Voltage at 25°C

Pick Up Voltage (Max)

at 25°C

Drop Out Voltage

(Min) at 25°C

Power Consumption

at rated Voltage

6 4.2

110% Of

Rated Voltage

85% Of

Rated Voltage

30% Of

Rated VoltageApprox. 3.4VA

12 18

24 72

110 1580

120 1700

220 5500

240 7200

Page 58: CATALOGUE - Sentien Electronicssentien-electronics.com.au/catalogues/SENTIEN_CATALOGUE.pdf · for a better protection between bezel and metal panel. TECHNICAL DATA CONTROL RANGE -50÷120°C

58

RELAYS

735 RELAY

FEATURES

• Industry standard octal-type termination

for quick installation.

• Contact arrangements from 1 form A

to 3 form C.

• Indicator lamp and push-to-test button

option available.

• Anti-sticking contact midget.

ORDERING INFORMATION

CONTACT RATING (RATED LOAD)

RESISTIVE LOAD1A, 1B, 1C, 2A, 2B, 2C 3A, 3B, 3C

20A/240VAC, 15A/28VDC 20A/240VAC, 15A/240VAC/28VDC

MOTOR 3/4 HP 120VAC, 1 HP 240VAC 1/2 HP 120VAC/240VAC

735

Type 735

Enclosure StyleBlank: Open TypeC: Plastiv Dust CoverC1: Mounting Ears on CoverC2: Accessible mounting hole with Antirotation TabC3: Mounting Ears on top of Cover

Contact Form1A: SPNO1B: SPNC1C: SPDT2A: DPNO2B: DPNC2C: DPDT3A: TPNO3B: TPNC3C: TPDT

Coil Voltage

OptionalBlank: No Special FeatureL: Provided LampM: Push ButtonT: PCB Terminal

LMT 12VDC-C1-3C

COIL DATA 735 (AC)

RATED VOLTAGE (V) RATED CURRENT

± 10% AT 25°C

(MA)

COIL RESISTANCE

± 10% AT 25°C

(Ω)

MAX.

CONTINUOUS

VOLTAGE AT 25°C

PICK UP VOLTAGE

(MAX) AT 25°C

DROP OUT VOLTAGE

(MIN) AT 25°C

POWER

CONSUMPTION AT

RATED VOLTAGE

SP

DP

6 188 32

110% Of

Rated Voltage

80% Of

Rated Voltage

10% Of

Rated Voltage

Approx. 1.2W

12 100 120

24 51 472

48 27 1800

110 11 10000

125 12.5 10000

TP

6 250 24

Approx. 1.5W

12 125 96

24 63 384

48 31 1536

110 11.5 9600

125 13 9600

CONTACT RATING (RATED CSA APPROVAL RATING)

RESISTIVE LOAD

1A, 1B, 1C 2A, 2B, 2C 3A, 3B, 3C

25A/277VAC/28VDC

10A/600VAC

25A/277VAC/28VDC

10A/600VAC

20A/277VAC

15A/28VDC

MOTOR1.5 HP 240VAC

1 HP 120VAC

1.5 HP 240VAC

1 HP 120VAC

1 HP 240VAC

3/4 HP 120VAC

Page 59: CATALOGUE - Sentien Electronicssentien-electronics.com.au/catalogues/SENTIEN_CATALOGUE.pdf · for a better protection between bezel and metal panel. TECHNICAL DATA CONTROL RANGE -50÷120°C

59

RELAYS

841 RELAY

FEATURES

• Industry Standard Octal-Type Termination

for quick installation.

• Contact arrangements from 1 form A

to 3 form C.

• Indicator lamp and push-to-test botton

option available.

• Anti-sticking contact midget.

ORDERING INFORMATION

COIL DATA (AC)

Rated Voltage (V) Coil Resistance

± 10% at 25°C (Ω)

Max. Continuous

Voltage at 25°C

Pick Up Voltage (Max)

at 25°C

Drop Out Voltage

(Min) at 25°C

Power Consumption

at rated Voltage

6 275

110% Of

Rated Voltage

80% Of

Rated Voltage

10% Of

Rated Voltage

Approx.

1.7VA ~ 2.7VA

12 138

24 74

48/50 39/40

100/120 18.7/22.1

200,240 9.1/10.8

COIL DATA SCL (DC)

RATED VOLTAGE

(V)

RATED CURRENT

± 10% AT 25°C

(MA)

COIL RESISTANCE

± 10% AT 25°C

(Ω)

MAX.

CONTINUOUS

VOLTAGE AT 25°C

PICK UP VOLTAGE

(MAX) AT 25°C

DROP OUT

VOLTAGE (MIN) AT

25°C

POWER

CONSUMPTION AT

RATED VOLTAGE

3 638 4.7

110% Of

Rated Voltage

75% Of

Rated Voltage

10% Of

Rated VoltageApprox. 1.92W

6 319 18.8

12 160 75

24 80 300

48/50 40/411.6 1200

100 19.2 5200

110 17.4 6300

200 9.5 21000

CONTACT RATING

LOAD TYPE 1A (SPDM) 2A (DPDM)

RATED LOAD (RESISTANCE) 30A/22VAC 25A/220VAC

MAX. SWITCHING CURRENT 30A 25A

MAX. SWITCHING VOLTAGE 277VAC 277VAC

MAX. SWITCHING CAPACITY 6600VAC 5500VAC

841

Type 841

Contact Form1A: SPDM Single Polw Double Make2A: DPDM Double POle Double Make

S: Quick TerminalP: P C B Terminal

Coil Voltage

Blank: Standard TypeH: High Insulation Type(Enlarge Contact Spacing)

Cover TypeC: Flux Free TypeD: Dust CoverS: Sealed Type

-1A -C -H 220VAC-S

Page 60: CATALOGUE - Sentien Electronicssentien-electronics.com.au/catalogues/SENTIEN_CATALOGUE.pdf · for a better protection between bezel and metal panel. TECHNICAL DATA CONTROL RANGE -50÷120°C

60

RELAYS

SOCKETS

PTF-08A FIT TO SCL, SCLA-S

PTF-08A FIT TO SCLA-W

PTF-08A FIT TO SCLD-W

Page 61: CATALOGUE - Sentien Electronicssentien-electronics.com.au/catalogues/SENTIEN_CATALOGUE.pdf · for a better protection between bezel and metal panel. TECHNICAL DATA CONTROL RANGE -50÷120°C

61

HC1 RELAYS

RELAYS

HC1 AC Contactor mainly applies to circuit of AC 50Hz (or 60Hz),

rated working voltage up to 400V, rated working current up to 63A

to control household electric applicances and low inductive reactance

load and micro inductive reactance load of similar usage, can also

be used to control household motor load of which controlling power

needs to be relatively decreased.This product applies to places

such as household, hotels, apartments, etc to realize the automation

of large scale produced household electric appliances. Its main

performance indicaes comply with standards of IE1095, etc.

APPLICATIONS

SPECIFICATION

HC1 RELAYS

RATED OPERATING CURRENTS AND POWER RATINGS

AC-1/AC-7A SWITCHING OF HEATERS HC1-20 HC1-23 HC1-40 HC1-63

RATED OPERATION CURRENT LE(NO) 20A 24A 40A 63A

RATED OPERATION CURRENT LE(NC) 20A 24A 30A 30A

RATED OPERATION POWER (NO) 2 current paths connected in parallel permit a 1.6 fold increase in rated operating current le.

230V SINGLE-PHASE 4.0KW 5.3KW 8.8KW 13.8KW

230V 3-PHASE — 9KW 15.2KW 24KW

400V 3-PHASE — 16KW 26KW 41KW

AC-3/AC-7B SWITCHING OF HEATERS HC1-20 HC1-23 HC1-40 HC1-63

RATED OPERATION CURRENT LE(NO) 9A 9A 22A 30A

RATED OPERATION CURRENT LE(NC) 9A 6A — —

RATED OPERATION POWER (NO)

230V SINGLE-PHASE 1.3KW 1.3KW 3.7KW 5KW

230V 3-PHASE — 2.2KW 5.5KW 8KW

400V 3-PHASE — 4KW 11KW 15KW

HC1 RELAYS

Page 62: CATALOGUE - Sentien Electronicssentien-electronics.com.au/catalogues/SENTIEN_CATALOGUE.pdf · for a better protection between bezel and metal panel. TECHNICAL DATA CONTROL RANGE -50÷120°C

62

FEATURES

RELAYS

SOLID STATE RELAYS

SERIES MODEL NO.MAX. LOAD

CURRENTLOAD VOLTAGE

BLOCKING

VOLTAGE

INPUT CONTROL

VOLTAGE

MUST TURN OFF

VOLTAGE

KB20C02A 02A, 03A, 04A, 0A 24 – 280VAC 600VAC PEAK3 – 32VDC 1VDC

KB40C04A 04A, 06A 24 – 480VAC 1200VAC PEAK

10-2-20C02A1 / 2 / 4 / 8 PORTS

02A, 04A24 – 280VAC 600VAC PEAK

3 – 32VDC 1VDC

10-4-40C02A1 / 2 / 4 / 8 PORTS

02A, 04A24 – 480VAC 1200VAC PEAK

KD20C25AX

10A, 25A, 40A,

50A, 75A, 90A,

100A

24 – 280VAC 600VAC PEAK 4 – 32VDC 1VDC

KD40C75AX

10A, 25A, 40A,

50A, 75A, 90A,

100A

48 – 480VAC 1200VAC PEAK 4 – 32VDC 1VDC

KF0602D

KF0604D

2A

4A3 – 60VDC 80VDC 3 – 32VDC 1VDC

10-2-0602D1 / 2 / 4 / 8 PORTS

02A3 – 60VDC 80VDC

3 – 32VDC 1VDC

10-2-0604D1 / 2 / 4 / 8 PORTS

04A3 – 60VDC 80VDC

KG1005D05, 12, 25, 40,

50, 755 – 120VDC 140VDC

3 – 32VDCKG2075D

10, 25, 40, 50, 75 5 – 240VDC 300VDC

KL20C40AX

10A, 25A, 40A,

50A, 75A, 90A,

100A

24 – 280VAC 600VAC PEAK 80 – 280VAC 10VAC

KL40C90AX

10A, 25A, 40A,

50A, 75A, 90A,

100A

48 – 480VAC 1200VAC PEAK 80 – 280VAC 10VAC

KR2025AX 10A, 25A, 40A 24 – 280VAC 600VAC PEAK BR500KΩ PHASE CONTROL

KR4040AX 25A, 40A 48 – 480VAC 1200VAC PEAK VR1MΩANALOG

SWITCHING

3 PHASE – SOLID STATE RELAY

SERIES MODEL NO. LOAD CURRENT LOAD VOLTAGEBLOCKING

VOLTAGE

CONTROL

VOLTAGE

MUST TURN OFF

VOLTAGE

K3PH20C25DA25A, 40A, 50A,

75A, 90A, 100A24 – 280VAC 600VAC 6 – 32VDC 3VDC

K3PH40C75DA25A, 40A, 50A,

75A, 90A, 100A48 – 480VAC 1200VAC 12 – 32VDC 9.5VDC

K3PH20C025AA25A, 40A, 50A,

75A, 90A, 100A24 – 280VAC 600VAC 80 – 280VAC 10VAC

K3PH40C75AA25A, 40A, 50A,

75A, 90A, 100A48 – 480VAC 1200VAC 80 – 280VAC 10VAC

K3PI20C25DA25A, 40A, 50A,

75A, 90A, 100A24 – 280VAC 600VAC 6 – 32VDC 3VDC

K3PI40C40DA25A, 40A, 50A,

75A, 90A, 100A48 – 480VAC 1200VAC 12 – 32VDC 9.5VDC

K3PI20C75AA25A, 40A, 50A,

75A, 90A, 100A24 – 280VAC 600VAC 80 – 280VAC 10VAC

K3PI40C90AA25A, 40A, 50A,

75A, 90A, 100A48 – 480VAC 1200VAC 80 – 280VAC 10VAC

Page 63: CATALOGUE - Sentien Electronicssentien-electronics.com.au/catalogues/SENTIEN_CATALOGUE.pdf · for a better protection between bezel and metal panel. TECHNICAL DATA CONTROL RANGE -50÷120°C

63

RELAYS

SOLID STATE RELAYS & ACCESSORIES

KB-KF SERIES 10-X SERIES

NOTE X= 2PORT/4PORT/8PORT

MODEL NO. DIMENSION

IO-2-20C04A 34 x 85 x 51

IO-4-20C04A 64 x 85 x 51

IO-8-20C04A 124 x 85 x 51

IO-2-20C04D 34 x 85 x 51

IO-4-20C04D 64 x 85 x 51

IO-8-20C04D 124 x 85 x 51

KD-KG-KL-KR SERIES

KD-KG-KL-KR SERIES

KD-KG-KL-KR SERIES

MODEL NO. FOR 1Φ SSR MODEL NO. FOR 1Φ SSR MODEL NO. FOR 1Φ SSR MODEL NO. FOR 1Φ SSR MODEL NO. FOR 1Φ SSR

H060 – 50 10A – 15A H080 – 50 25A H100 – 45 10A H104 – 104 25A – 40A H197 – 100 25A, 40 A

H060 – 80 25 H080 – 100 40A H100 – 70 25A H104 – 104F 40A – 50A

H060 – 100 40A H080 – 150 50A H100 – 100 40A H104 – 120F 50A – 75A

H060 – 120 50A H100 – 120 50A H104 – 150F 75A – 100A

H060 – 150 75A H100 – 150 75, 100A "F" with fan (110V or 220VAC)

H050-50 (FOR 1Φ, 10A)

Page 64: CATALOGUE - Sentien Electronicssentien-electronics.com.au/catalogues/SENTIEN_CATALOGUE.pdf · for a better protection between bezel and metal panel. TECHNICAL DATA CONTROL RANGE -50÷120°C

64

SWITCHES

CURRENT SWITCHES

RIBXK SERIES – CURRENT SENSOR – ENCLOSED SOLID CORE CURRENT SENSORS

RIBXG SERIES – CURRENT SENSOR – ENCLOSED SPLIT CORE CURRENT SENSORS

MODEL NO. RANGE TYPE THRESHOLD OUTPUT LED 1 LED 2

RIBXKF .25 – 150 Amp SOLID CORE FIXED SOLID STATE SWITCH SPST ; 30 VAC/DC ; .4 AMPS MAX (WHT/YEL 16" 18 AWG WIRE LEADS)

RIBXKTF .25 – 150 Amp SOLID CORE FIXED SOLID STATE SWITCH SPST ; 30 VAC/DC ; .4 AMPS MAX (TERMINAL STRIP, ACCEPTS #14-22 AWG WIRE)

RIBXKA .50 – 150 Amp SOLID CORE ADJUSTABLE SOLID STATE SWITCH SPST ; 30 VAC/DC ; .8 AMPS MAX (WHT/YEL 16" 18 AWG WIRE LEADS) OVER TRIP POINT UNDER TRIP POINT

RIBXKTA .50 – 150 Amp SOLID CORE ADJUSTABLE SOLID STATE SWITCH SPST ; 30 VAC/DC ; .8 AMPS MAX (TERMINAL STRIP, ACCEPTS #14-22 AWG WIRE) OVER TRIP POINT UNDER TRIP POINT

MODEL NO. RANGE TYPE THRESHOLD OUTPUT LED 1 LED 2

RIBXGF .35 – 150 AMP SPLIT CORE FIXED SOLID STATE SWITCH SPST ; 30 VAC/DC ; .4 AMPS MAX (WHT/YEL 16" 18 AWG WIRE LEADS)

RIBXGFL .75 – 150 AMP SPLIT CORE FIXED SOLID STATE SWITCH SPST ; 30 VAC/DC ; .4 AMPS MAX (WHT/YEL 16" 18 AWG WIRE LEADS) OVER TRIP POINT

RIBXGTF .35 – 150 AMP SPLIT CORE FIXED SOLID STATE SWITCH SPST ; 30 VAC/DC ; .4 AMPS MAX (TERMINAL STRIP, ACCEPTS #14-22 AWG WIRE)

RIBXGTFL .75 – 150 AMP SPLIT CORE FIXED SOLID STATE SWITCH SPST ; 30 VAC/DC ; .4 AMPS MAX (TERMINAL STRIP, ACCEPTS #14-22 AWG WIRE) OVER TRIP POINT

RIBXGA .75 – 150 AMP SPLIT CORE ADJUSTABLE SOLID STATE SWITCH SPST ; 30 VAC/DC ; .4 AMPS MAX (WHT/YEL 16" 18 AWG WIRE LEADS) OVER TRIP POINT UNDER TRIP POINT

RIBXGTA .75 – 150 AMP SPLIT CORE ADJUSTABLE SOLID STATE SWITCH SPST ; 30 VAC/DC ; .4 AMPS MAX (TERMINAL STRIP, ACCEPTS #14-22 AWG WIRE) OVER TRIP POINT UNDER TRIP POINT

SPECIFICATIONS

SPECIFICATIONS

OPERATING TEMPERATURE -30 to 140°F

MAX SENSE VOLTAGE 600 VAC

APPROVALS UL Listed, UL916, UL864, C-UL, CE

HOUSING RATING Plenum, NEMA 1

MOUNTING/ Removable mounting tab provided.

INSTALLATION The wire clamp locks against the load

wire, securing the unit in place.

RIBXKA

RIBXKTF

OPERATING TEMPERATURE -30 to 140°F

MAX SENSE VOLTAGE 600 VAC

APPROVALS UL Listed, UL916, UL864, C-UL, CE

HOUSING RATING Plenum, NEMA 1

MOUNTING / Removable mounting tab provided

INSTALLATION The wire clamp locks against the load

wire, securing the unit in place.

RIBXGA

RIBXGTF

SENSOR OUTPUTSOLID STATE CONTACT30VAC / DC0.4 AMP MAX. RIBXKF, RIBXKTF0.8 AMP MAX. RIBXKA, RIBXKTAWhen current sensor status is off (open)Leakage <30 uA @ 30VAC/DCWhen current sensor status is on (closed)Voltage Drop <0.3VAC/DC @ 0.1AMP <1.6VAC/DC @ 0.4 AMP

SENSOR OUTPUTSOLID STATE CONTACT30VAC / DC 0.4 AMPWhen current sensor status is off (open)Leakage <30 uA @ 30VAC/DCWhen current sensor status is on (closed)Voltage Drop <0.3VAC/DC @ 0.1AMP <1.6VAC/DC @ 0.4 AMP

Page 65: CATALOGUE - Sentien Electronicssentien-electronics.com.au/catalogues/SENTIEN_CATALOGUE.pdf · for a better protection between bezel and metal panel. TECHNICAL DATA CONTROL RANGE -50÷120°C

65

CURRENT SWITCHES

SWITCHES

RIBXGH SERIES – SWITCHING CURRENT SENSOR – SPLIT CORE 120VAC SWITCHING CURRENT SENSORS

RIBKTV SERIES – CURRENT TRANSDUCER – ENCLOSED SOLID CORE CURRENT TO VOLTAGE TRANSDUCERS

OPERATING TEMPERATURE -30 to 140°F

TEMPERATURE DERATING 1 Amp up to 50°C,

0.5 Amp up to 60°C

MAX SENSE VOLTAGE 600 Vac

APPROVALS UL Listed, UL916, C-UL, CE

HOUSING RATING Plenum, NEMA 1

MOUNTING / Removable mounting tab provided.

INSTALLATION The wire clamp locks against the load

wire, securing the unit in place.

MODEL NO. RANGE TYPE THRESHOLD OUTPUT LED 1 LED 2

RIBXGHF 0.5-150 AMP SPLIT CORE FIXED SOLID STATE SWITCH SPST ; 120 VAC/DC ; 1 AMPS MAX (WHT/BLK 16" 18 AWG WIRE LEADS)

RIBXGHTF 0.5-150 AMP SPLIT CORE FIXED SOLID STATE SWITCH SPST ; 120 VAC/DC ; 1 AMPS MAX (TERMINAL STRIP, ACCEPTS #14-22 AWG WIRE)

RIBXGHA .75-150 AMP SPLIT CORE ADJUSTABLE SOLID STATE SWITCH SPST ; 120 VAC/DC ; 1 AMPS MAX (WHT/BLK 16" 18 AWG WIRE LEADS) OVER TRIP POINT UNDER TRIP POINT

RIBXGHTA .75-150 AMP SPLIT CORE ADJUSTABLE SOLID STATE SWITCH SPST ; 120 VAC/DC ; 1 AMPS MAX (TERMINAL STRIP, ACCEPTS #14-22 AWG WIRE) OVER TRIP POINT UNDER TRIP POINT

MODEL NO. RANGE OUTPUT

RIBXKTV5-10 0 – 10 AMP 0 – 5 VDC (TERMINAL STRIP, ACCEPTS #14-22 AWG WIRE)

RIBXKTV5-20 0 – 20 AMP 0 – 5 VDC (TERMINAL STRIP, ACCEPTS #14-22 AWG WIRE)

RIBXKTV5-50 0 – 50 AMP 0 – 5 VDC (TERMINAL STRIP, ACCEPTS #14-22 AWG WIRE)

RIBXKTV5-100 0 – 100 AMP 0 – 5 VDC (TERMINAL STRIP, ACCEPTS #14-22 AWG WIRE)

OPERATING TEMPERATURE -30 to 140°F

ACCURACY 96.8% Full Scale

LOADING RIBXKTV5-10, 1% Error @ 180 kΩ

RIBXKTV5-20, 1% Error @ 90 kΩ

RIBXKTV5-50, 1% Error @ 40 kΩ

RIBXKTV5-100, 1% Error @ 15 kΩ

MAX SENSE VOLTAGE 600 VAC

APPROVALS UL Listed, UL916, UL864, C-UL, CE

HOUSING RATING Plenum, NEMA 1

SENSOR TYPE Solid core with voltage output

MOUNTING/ Removable mounting tab provided.

INSTALLATION The wire clamp locks against the load

wire, securing the unit in place.

SPECIFICATIONS

SPECIFICATIONS

RIBGHF

RIBXGHTF

SENSOR OUTPUTSOLID STATE CONTACT120VAC, 1AMP MAX.

Page 66: CATALOGUE - Sentien Electronicssentien-electronics.com.au/catalogues/SENTIEN_CATALOGUE.pdf · for a better protection between bezel and metal panel. TECHNICAL DATA CONTROL RANGE -50÷120°C

66

SWITCHES

CURRENT SWITCHES

RIBXK 420 SERIES – CURRENT TRANSDUCER – ENCLOSED 20, 50, AND 100 AMP CURRENT TRANDUCERS WITH LOOP POWERED 4 – 20

RIBXF SERIES – CURRENT SENSOR – ENCLOSED INTERNAL FIXED 0.50-30 AMP CURRENT SENSOR

RIBXA SERIES - CURRENT SENSOR - ENCLOSED INTERNAL ADJUSTABLE 0.50-30 AMP CURRENT SENSOR

MODEL NO. RANGE OUTPUT

RIBXK420-20 0 – 20 AMP LOOP POWERED 4-20 MA TRANSMITTER (PRE-WIRED)

RIBXK420-50 0 – 50 AMP LOOP POWERED 4-20 MA TRANSMITTER (PRE-WIRED)

RIBXK420-100 0 – 100 AMP LOOP POWERED 4-20 MA TRANSMITTER (PRE-WIRED)

SPECIFICATIONS

OPERATING TEMPERATURE -30 to 140°F

MAX SENSE VOLTAGE 600 VAC

APPROVALS UL Listed, UL916, UL864, C-UL, CE

HOUSING RATING Plenum, NEMA 1

MOUNTING/ Removable mounting tab provided.

INSTALLATION The wire clamp locks against the load

wire, securing the unit in place.

PRODUCT SPECIFICATIONSOPERATING TEMPERATURE -30 to 140°F

DIMENSIONS 4.00" x 4.00" x 1.80" with .50" NPT Nipple

WIRE LENGTH 16", 600V Rated

APPROVALS UL Listed, UL916, UL864, C-UL,

California State Fire Marshal, CE

HOUSING RATING Plenum, NEMA 1

SENSOR TYPE Internal, with contact status

SENSOR THRESHOLD Fixed, .5 Amps

SENSOR RANGE .50 – 30 Amps

SENSOR OUTPUT Solid Stare Contact 30 Vac/dc, 0.4 Amp

MAX SENSE VOLTAGE 600 VAC

PRODUCT SPECIFICATIONSOPERATING TEMPERATURE -30 to 140°F

DIMENSIONS 4.00" x 4.00" x 1.80" with .50" NPT Nipple

WIRE LENGTH 16", 600V Rated

APPROVALS UL Listed, UL916, UL864, C-UL,

California State Fire Marshal, CE

HOUSING RATING Plenum, NEMA 1

SENSOR TYPE Internal, with contact status

SENSOR THRESHOLD Adjustable, 0.50 – 30 Amps

SENSOR RANGE .50 – 30 Amps

SENSOR OUTPUT Solid Stare Contact 30 Vac/dc, 0.4 Amp

MAX SENSE VOLTAGE 600 VAC

MAXIMUM OUTPUT LOAD RESISTANCE SUPPLY VOLTAGE

MINIMUM MAXIMUM

800 OHMS 24 VDC 35 VDC

500 OHMS 18 VDC 35 VDC

350 OHMS 15 VDC 35 VDC

250 OHMS 13 VDC 30 VDC

200 OHMS 12 VDC 30 VDC

100 OHMS 10 VDC 28 VDC

50 OHMS 9 VDC 28 VDC

Solid State Contact30VAC/DC 0.4 AMP MAX.

SENSOR FEEDBACKCURRENT SENSOR STATUS

CURRENTSENSORCIRCUITRY

PRP

PRPNOT USED

When Current Sensor status is off (open)Leakage <30 uA @ 30VAC/DCWhen Current Sensor status is on (closed)Voltage Drop <0.3 VAC/DC @ 0.1 AMP <1.6 VAC/DC @ 0.4 AMP

Solid State Contact30VAC/DC 0.4 AMP MAX.

SENSOR FEEDBACKCURRENT SENSOR STATUS

CURRENTSENSORCIRCUITRY

PRP

PRPNOT USED

When Current Sensor status is off (open)Leakage <30 uA @ 30VAC/DCWhen Current Sensor status is on (closed)Voltage Drop <0.3 VAC/DC @ 0.1 AMP <1.6 VAC/DC @ 0.4 AMP

Page 67: CATALOGUE - Sentien Electronicssentien-electronics.com.au/catalogues/SENTIEN_CATALOGUE.pdf · for a better protection between bezel and metal panel. TECHNICAL DATA CONTROL RANGE -50÷120°C

67

ELECTRICAL SWITCHES

SWITCHES

SPECIFICATION

701X SERIES

702X SERIES

1. RATING 20A 250VAC.

2. INSULATION RESISTANCE

DC 500V 200MO or more

3. CONTACT RESISTANCE

DC 2 – 4V 1A 20MO or less

4. WITHSTAND VOLTAGE

AC 1500V or more

SWITCH FUNCTION

MODEL NO. OPERATIONS

7011 ON — OFF SPST

7012 ON — ON SPDT

7013 ON OFF ON SPDT

7014 (ON) OFF SPST

7015 ON — (ON) SPDT

7016 (ON) OFF (ON) SPDT

7017 ON OFF (ON) SPDT

7021 ON — OFF DPST

7022 ON — ON DPDT

7023 ON OFF ON DPDT

7024 (ON) OFF DPST

7025 ON — (ON) DPDT

7026 (ON) OFF (ON) DPDT

7027 ON OFF (ON) DPDT

TERMINAL'S TYPE

A SOLDER TERMINAL

B SREW TERMINAL

C QUICK TERMINAL

KEYWAY

KEYWAY

KEYWAY

Page 68: CATALOGUE - Sentien Electronicssentien-electronics.com.au/catalogues/SENTIEN_CATALOGUE.pdf · for a better protection between bezel and metal panel. TECHNICAL DATA CONTROL RANGE -50÷120°C

68

SWITCHES

ELECTRICAL SWITCHES

ACCESSORIES

W-70A

P-70

K-82A

W-30

C-MTA

P-MT

K-82B

W-30B

FOR 70XX

FOR 70XX

FOR 21XX

FOR 3018, 30193020, 3022

FOR MTXX

FOR MTXX

FOR 1101, 1102, 8105, 8105B

FOR 306X

PITCH'S TYPE

A M12.0XP1.0

B M12.0XP0.75

ENFACE TYPE

A ON – OFF

B ON – ON

C ON – OFF – ON

ENFACE TYPE

A ON – OFF

B ON – ON

C ON – OFF – ON

Page 69: CATALOGUE - Sentien Electronicssentien-electronics.com.au/catalogues/SENTIEN_CATALOGUE.pdf · for a better protection between bezel and metal panel. TECHNICAL DATA CONTROL RANGE -50÷120°C

69

ROCKER SWITCHES

SWITCHES

RH SERIES

SPECIFICATIONS

• 16A 125VAC 1/4HP (UL CSA)

• 16A 250VAC 1/4HP (UL, CSA)

• 20A 125VAC 3/4HP (UL)

• 16(4) 250V~T85 1E4 , 10(2)A 250V~5E4

(VDE, SEMKO, DEMKO, NEMKO, FIMKO, SEV)

• INITIAL CONTACT RESISTANCE 20m Ω max.

• INSULATION RESISTANCE 100m Ω min, at 500VDC

• DIELECTRIC STRENGTH 1,000VAC for 1 minute

• ELECTRIC LIFE 16(4) A 250VAC : 10,000 cycles

10(2) A 250VAC : 50,000 cycles

• TEMPERATURE RANGE -20°C to + 85°C

• Switch for Class II appliances

• BASE Nylon 66, UL rated : 94V-2 min

• ACTUATOR Nylon 66/PC, UL rated 94V-2 min

• SPRING Piano Wire

• CONTACT Silver-Cadmium Alloy

• LAMP Neon, Fluorescent for AC; Tungsten bulb for DC

Illuminated types offer only ON-OFF function

• Scallop-shaped types offer only ON-OFF, ON-ON for

non-illumination,ON-OFF for full illumination (Lens unavailable)

SINGLE POLE ROCKER SWITCHES UP TO 20A 125VAC – ROUND OR SQUARE LEN ILLUMINATED

PANEL CUT-OUT

SNAP-IN MOUNTING

PANEL CUT-OUT ( X = PANEL THICKNESS )

X Y DIM.Z

0.75 TO 1.25MM 30.0+0/-0.1 11.0+0.1/-0

1.25 TO 2MM 30.2+0/-0.1 11.0+0.1/-0

2 TO 3MM 30.5+0/-0.1 11.0+0.1/-0

Page 70: CATALOGUE - Sentien Electronicssentien-electronics.com.au/catalogues/SENTIEN_CATALOGUE.pdf · for a better protection between bezel and metal panel. TECHNICAL DATA CONTROL RANGE -50÷120°C

70

PANEL CUT-OUT

SNAP-IN MOUNTING

ROCKER SWITCHES

SWITCHES

R SERIES

SPECIFICATIONS

DOUBLE POLE ROCKER SWITCHES UP TO 20A 125VAC – ROUND OR SQUARE LEN ILLUMINATED

• 16A 125VAC 1/4HP (UL CSA)

• 16A 250VAC 1/4HP (UL, CSA)

• 20A 125VAC 3/4HP (UL)

• 16(4) 250V~T85 1E4 , 10(2)A 250V~5E4

(VDE, SEMKO, DEMKO, NEMKO, FIMKO, SEV)

• INITIAL CONTACT RESISTANCE 20m Ω max.

• INSULATION RESISTANCE 100m Ω min, at 500VDC

• DIELECTRIC STRENGTH 1,000VAC for 1 minute

• ELECTRIC LIFE 16(4) A 250VAC : 10,000 cycles

10(2) A 250VAC : 50,000 cycles

• TEMPERATURE RANGE -20°C to + 125°C

• Switch for Class II appliances

• BASE Nylon 66, UL rated: 94V-2 min

• ACTUATOR Nylon 66/PC, UL rated 94V-2 min

• SPRING Piano Wire

• CONTACT Silver-Cadmium Alloy

• TERMINALS Silver Plated Copper

• LAMP Neon, Fluorescent for AC; Tungsten bulb for DC

Illuminated types offer only ON-OFF function

• Flat actuator offeres only full-illumination (no Len)

PANEL CUT-OUT ( X = PANEL THICKNESS )

X Y DIM.Z

0.75 TO 1.25MM 30.0+0/-0.1 22.0+0.15/-0

1.25 TO 2MM 30.2+0/-0.1 22.0+0.15/-0

2 TO 3MM 30.5+0/-0.1 22.0+0.15/-0

Page 71: CATALOGUE - Sentien Electronicssentien-electronics.com.au/catalogues/SENTIEN_CATALOGUE.pdf · for a better protection between bezel and metal panel. TECHNICAL DATA CONTROL RANGE -50÷120°C

71

ROCKER SWITCHES

SWITCHES

BR1-12

SPECIFICATIONS

BR1-12-13L

• RATING 12A 125VAC, 12A 250VAC (UL, CSA) 12(4)A 250V~μ

T85(SEMKO, DEMKO, NEMKO, FIMKO)

• CONTACT RESISTANCE 20m Ω (max)

• INSULATION RESISTANCE DC500V 100M Ω (min.)

• DIELECTRIC VOLTAGE-WITHSTAND 1,000VAC for 1 minute

• OPERATION FORCE 700 ± 200gram

• LIFE CYCLE 10,000 cycles

• TEMPERATURE RANGE -20°C to + 85°C

• BASE Nylon 66, UL rated 94V-2 min

• ACTUATOR PC, UL rated 94V-2 min

• TERMINAL Copper and Brass

• SPRING Steel Wire

• CONTACT Silver Copper Alloy

• NEON LAMP Neon, Fluroescent

• SWITCH FUNCTION on-off

ROUND ILLUMINATED MINI-ROCKER SWITCHES UP TO 12A 125VAC – SNAP-IN MOUNTING, CURVE ROUND PANEL

PANEL CUT-OUT

21.00 ± 0.1

2.4

0 ±

0.1

20.0

0 +

0.3

0

0.0

0

Page 72: CATALOGUE - Sentien Electronicssentien-electronics.com.au/catalogues/SENTIEN_CATALOGUE.pdf · for a better protection between bezel and metal panel. TECHNICAL DATA CONTROL RANGE -50÷120°C

72

PUSH BUTTON SWITCHES 22Φ / 25Φ

SWITCHES

NPB22-F NLB22-F

NPB22 - F 11 G A 1 2 3 4 5

1. CURRENT RATING (max.)

F Flush Head BMushrom Head

(Protect the ring) 65Φ F Flush Head

E Elevation Head RReset Mushroom

Head 40Φ PFlush Head

(Rubber Cap)

PElevation Head

(Rubber Cap)V

Reset Mushroom Head

(Protect the ring) 65Φ LElevation Head

(Protect the ring)

LElevation Head

(Protect the ring)S

Push-Pull Stop

Mushroom Head 35Φ M Mushroom Head 40Φ

M Mushroom Head 40Φ D Double Push Buttom RReset Mushroom

Head 40Φ

KMushroom Head

(With key) 40Φ D Double Push Button

3. CONTACT BLOCKS

10 1a 21 2a1b

01 1b 12 1a2b

11 1a1b 22 2a2b

20 2a 02 2b

1. SERIES

NPB22 Non-Illuminated

NLB22 Illuminated

5. VOLTAGE RATING

NLB22

A AC.DC.24V

E AC.DC.100-120V

I AC.DC.220-240V

4. CAP COLOUR

NPB22 NLB22

R Red R Red

G Green G Green

Y Yellow Y Yellow

S Blue

B Black

NPB22

MODEL DESIGNATION

Page 73: CATALOGUE - Sentien Electronicssentien-electronics.com.au/catalogues/SENTIEN_CATALOGUE.pdf · for a better protection between bezel and metal panel. TECHNICAL DATA CONTROL RANGE -50÷120°C

73

SWITCHES

PUSH BUTTON SWITCHES 22Φ / 25Φ

SPECIFICATION

NPB22-E

NPB22-P

NPB22-M

NPB22-R

NLB22-F

NLB22-P

NLB22-M

NLB22-R

Page 74: CATALOGUE - Sentien Electronicssentien-electronics.com.au/catalogues/SENTIEN_CATALOGUE.pdf · for a better protection between bezel and metal panel. TECHNICAL DATA CONTROL RANGE -50÷120°C

74

SWITCHES

FLOW SWITCHES

LIQUID FLOW SWITCH

LIQUID FLOW SWITCH

TYPE FF81• Casing in shock-proof thermoplastic

with self-retaining screws

• Threaded brass connection G1 Nylon cable

gland G 3/8

• AISI 301 stainless steel blades from G1 to G4

• Protection class 2

TYPE FF84• Stainless steel case

• Threaded brass connection G1

• Nickel-plated brass cable gland G 3/8

• Protection Class 1

• AISI 301 Stainless Steel Blades from G1 to G10

• Electric connections on Faston 6.3 (provided)

• SPDT Single-pole Switching Microswitch

ELECTRIC SPECIFICATIONSRATED INSULATION VOLTAGE Ui 380V~

CONTINUOUS DUTY RATED CURRENT LTH 10A

RATED OPERATING CURRENT IE 220V~ 250V~

RESISTANCE LOAD AC-12 10A

INDUCTIVE LOAD AC-15 3A

DIRECT CURRENT DC-13 0,2A

• Casing in shock-proof thermoplastic AISI 301

stainless steel blades for pipes from G1" to G8"

• Direct fixing by threaded connection G1"

ELECTRIC SPECIFICATIONSRATED INSULATION VOLTAGE Ui 380V~

CONTINUOUS DUTY RATED CURRENT LTH 10A

RATED OPERATING CURRENT IE: 220V~ 250V~

RESISTANCE LOAD AC-12 16A

INDUCTIVE LOAD AC-15 6A

DIRECT CURRENT DC-13 0.2A

TYPEPIPE

DIAMETER

MINIMUM CALIBRATION VALUE

(dm/sec) WITH FLOW:

MAXIMUM CALIBRATION VALUE

(dm/sec) WITH FLOW:MAXIMUM

OPERATING

PRESSURE

TEMPERATURE

RANGE

MAXIMUM

AMBIENT

TEMPERATURE

PROTECTION

LEVELINCREASING DECREASING INCREASING DECREASING

FF84

FF81

G1 0,26 0,16 0,58 0,53

10 BAR -20 TO 110°C 50°C IP54G2 0,8 0,6 1,7 1,6

G3 1,7 1,2 3,2 3

G4 2,2 1,7 5,1 4,8

G6 4,7 3,4 9 8,5

10 BAR -20 TO 110°C 50°C IP54G8 12,9 10,7 26 25,2

G10 26,5 22 43,5 41

TYPEPIPE

DIAMETER

PADDLE

LENGTH

MINIMUM CALIBRATION VALUE

(dm/sec) WITH FLOW:

MAXIMUM CALIBRATION VALUE

(dm/sec) WITH FLOW: TEMPERATURE

RANGE

PROTECTION

LEVELINCREASING DECREASING INCREASING DECREASING

FF82

G1 35 1 0,5 2 1,9

-20 TO 110°C IP65

G1 1/4 35 1,2 0,7 2,9 2,7

G1 1/2 58 1,6 1 3,9 3,6

G2 58 2,9 2,1 6,1 5,7

G2 1/2 89 4 2,7 7 6,5

G3 89 6,1 4,3 11,4 10,7

G489 14,7 11,3 28,9 27,6

167 7,9 6,1 18,4 17,3

G589 28,3 22,8 55,5 5,3

167 12,8 9,2 26,7 2,5

G689 43 35,8 85 81,6

167 16,8 12,2 32,5 30,5

G889 85 72,4 172,3 165,5

167 46,4 38,5 94 90,7

Page 75: CATALOGUE - Sentien Electronicssentien-electronics.com.au/catalogues/SENTIEN_CATALOGUE.pdf · for a better protection between bezel and metal panel. TECHNICAL DATA CONTROL RANGE -50÷120°C

75

SWITCHES

FLOW SWITCHES

LIQUID FLOW WITH PLASTIC BLADE

FLOW SWITCHES AND PRESSURE SWITCHES

TYPE FF81P• Casing in shock-proof thermoplastic with

self-retaining screws

• Threaded brass connection G1 Nylon cable gland

G 3/8 Non-toxic thermoplastic resin blade from

G4 with references for cut to G1 G2 G3

TYPE FF91P• Casing in shock-proof thermoplastic with

self-retaining screws

• Threaded brass connection G½ Nylon cable gland

G 3/8 Non-toxic thermoplastic resin blade from G2

with references for cut to G½ G1 G1½

ELECTRIC SPECIFICATIONSRATED INSULATION VOLTAGE Ui 380V~

CONTINUOUS DUTY RATED CURRENT lth 10A

RATED OPERATING CURRENT IE: 220V~ 250V~

RESISTANCE LOAD AC-12 10A

INDUCTIVE LOAD AC-15 3A

DIRECT CURRENT DC-13 0,2A

* For controlling drinking water 85°C

maximum recommended

TYPE PIPE DIAMETER

MINIMUM CALIBRATION VALUE

(dm/sec) WITH FLOW:

MAXIMUM CALIBRATION VALUE

(dm/sec) WITH FLOW: TEMPERATURE RANGEMAXIMUM AMBIENT

TEMPERATURE

PROTECTION

LEVELINCREASING DECREASING INCREASING DECREASING

FF81P

G1 0,26 0,16 0,58 0,53

G1 -20 TO 110°C * IP54G2 0,87 0,65 1,65 1,74

G3 1,85 1,3 3,49 3,27

G4 2,39 1,85 5,56 5,23

FF91P

G1/2 0,13 0,8 0,29 0,26

G1/2 -20 TO 110°C * IP54G1 0,26 0,16 0,58 0,53

G1 1/2 0,39 0,24 0,87 0,79

G2 0,8 0,6 1,7 1,6

CODE MODEL DESCRIPTION SIZE PRICE IN €

7.003.00084 SFP 1

Flow Switch - 1.5 l/min operating flow - Male connections -

(2 and 2.5 l/min operating flow

on request) with 1 microswitch

1/2" - 1/2" 43, 60

7.003.00076 SFP 2

Flow Switch - 1.5 l/min operating flow - Male connections -

(2 and 2.5 l/min operating flow

on request) with 2 microswitches

1/2" - 1/2" 46, 20

7.003.00258SFP-RM

M1S

Flow Switch - 1.5 l/min operating flow - Male connections -

(2 and 2.5 l/min operating flow on request) with flow rate

regulator and 1 microswitch

1/2" - 1/2" 52, 10

CODE MODEL DESCRIPTION SIZE PRICE IN €

7.004.00022 SFS 1

Differential pressure switch - operating Δ pressure 50 mbar -

Male connections - (on request can trigger at 25/33/100 mbar)

- (3/8G - 7/16 UNF connections on request)

with 1 microswitch

1/4" 36, 6-

7.004.00049 SFS 2

Differential pressure switch - operating Δ pressure 50 mbar -

Male connections - (on request can trigger at 25/33/100 mbar)

- (3/8G - 7/16 UNF connections on request)

with 2 microswitches

1/4" 39, 90

CODE MODEL DESCRIPTION SIZE PRICE IN €

7.008.00056 SBP 1Differential pressure switch with overpressure valve - triggers at

100 mbar - Male connections - with 1 microswitch3/4" - 1/2" 46, 20

7.008.00043 SBP 2Differential pressure switch with overpressure valve - triggers at

100 mbar - Male connections - with 2 microswitches3/4" - 1/2" 52, 10

Page 76: CATALOGUE - Sentien Electronicssentien-electronics.com.au/catalogues/SENTIEN_CATALOGUE.pdf · for a better protection between bezel and metal panel. TECHNICAL DATA CONTROL RANGE -50÷120°C

76

SWITCHES

LEVEL SWITCHES

RSF16 AND RSF40 DROP FLOAT

MECHANICAL

The drop float has been designed to eliminate problems

associated with limescale build up around the pivot point

of a conventional float switch.

The drop float actuator allows the switch housing and float

pivots to be located above the surface of the liquid and provides

noramlly closed switch contact opening as the liquid level rises.

• Pivot Clear of Liquid

• Compact Design

• Available in Nylon, Polypopylene or PPS.

• Many variants are UL recognised components

FILE No. E171218

• WBS approval.

TECHNICAL SPECIFICATION RSF43 RSF44 RSF46

MATERIAL NYLON POLYPROPYLENEPOLYPHENYLENE

SULPHIDE (PPS)

COLOUR BLACK OPAQUE GREY

TEMP. RANGE °C

°F

-20 / +75

-4 / +167

-20 / +100

-4 / +212

-10 / +120

+14 / +248

MIN. FLUID S.G. 0.75 0.75 0.75

ELECTRICAL SPECIFICATION Y V

CONTACT FORM A25 C3

VA RATING 25 3

BREAKDOWN VOLTAGE DC 800 150

SWITCHING VOLTAGE AC 240 48

SWITCHING VOLTAGE DC 120 28

SWITCHING CURRENT MAX. A 0.6 0.25

Page 77: CATALOGUE - Sentien Electronicssentien-electronics.com.au/catalogues/SENTIEN_CATALOGUE.pdf · for a better protection between bezel and metal panel. TECHNICAL DATA CONTROL RANGE -50÷120°C

77

SWITCHES

LEVEL SWITCHES

RSF40 SERIES

MECHANICAL

This series of floatswitch offers the user a low cost, compact

design with a wide range of options. Available in Acetal, Nylon,

Polypropylene or PPS, most commonly used fluids are catered

for. The compact design makes this device ideal for size sensitive

applications. External mount variants are available in RSF70 or

RSF80 series. A drop Float version is available (see opposite)

for applications where the pivot needs to remain out of the liquid.

• Compact Design

• Available in Nylon, Polypopylene or PPS.

• WBS approval.

• Reliable Reedswitch

• User configurble switching options

• Alternative thread sizes available

• Many variants are UL recognised components FILE No. E171218

ELECTRICAL SPECIFICATION Y V

CONTACT FORM A25 C3

VA RATING 25 3

BREAKDOWN VOLTAGE DC 800 150

SWITCHING VOLTAGE AC 240 48

SWITCHING VOLTAGE DC 120 28

SWITCHING CURRENT MAX. A 0.6 0.25

TECHNICAL SPECIFICATION RSF41 RSF43 RSF44 RSF46

MATERIAL ACETAL NYLON POLYPROPYLENEPOLYPHENYLENE

SULPHIDE (PPS)

COLOUR RED BLACK OPAQUE GREY

TEMP. RANGE °C

°F

-10 / +60

+14 /

+140

-20 / +75

-4 / +167

-20 / +100

-4 / +212

-10 / +120

+14 / +248

MIN. FLUID S.G. 0.875 0.75 0.75 0.75

Page 78: CATALOGUE - Sentien Electronicssentien-electronics.com.au/catalogues/SENTIEN_CATALOGUE.pdf · for a better protection between bezel and metal panel. TECHNICAL DATA CONTROL RANGE -50÷120°C

78

SWITCHES

LEVEL SWITCHES

RSF50 SERIES

MECHANICAL

ELECTRICAL SPECIFICATION Z Y V

CONTACT FORM A10(RSF51/52) A25 C3

VA RATING 10 25 3

BREAKDOWN VOLTAGE DC 215 800 150

SWITCHING VOLTAGE AC 125 240 48

SWITCHING VOLTAGE DC 150 120 28

SWITCHING CURRENT MAX. A 0.5 0.6 0.25

The RSF50 series of floatswitch are miniature vertically mounted

devices designed to achieve reliable, economical liquid level sensing

with a minimum of insertion time. Manufactured in PVC, Nylon, PPS

and Polypropylene, most commonly used fluids are catered for (refer

to the factory for specific suitability details). Mounting is simple and

quick from the inside of the tank, nut and washer supplied. Many

variants carry WBS and UL approval.

• Reliable reedswitch contacts

• Available in Nylon, Polypopylene or PPS

• User configurable N/O or N/C operation

• Quick and simple to install

• WBS Approved

• Variety of switching options and available with 1/8" NPT taper thread

• Many variants are UL recognised components FILE No. E171218

TECHNICAL SPECIFICATION RSF51/52 RSF53 RSF54 RSF56

MATERIAL PVC NYLON POLYPROPYLENEPOLYPHENYLENE

SULPHIDE (PPS)

COLOUR LIGHT GREY BLACK OPAQUE GREY

TEMP. RANGE °C

°F

-20 / +60

-4 / +140

-20 / +75

-4 / +167

-20 / +100

-4 / +212

-10 / +120

+14 / +248

MIN. FLUID S.G. 0.7 0.8 0.8 0.85

Page 79: CATALOGUE - Sentien Electronicssentien-electronics.com.au/catalogues/SENTIEN_CATALOGUE.pdf · for a better protection between bezel and metal panel. TECHNICAL DATA CONTROL RANGE -50÷120°C

79

PRESSURE SWITCHES

SWITCHES

PRESSURE SWITCH FOR PRESSURE UP TO 28 BAR

PRESSURE SWITCH FOR PRESSURE UP TO 300 BAR

SHUTDOWN PRESSURE SWITCH WITH MANUAL RESET

• Sensitive element with Stainless Steel Diaphragm

• Metal Frame

• Shock-proof Thermoplastic Cover

• Compliance with standards CEI EN 60947-4-1

* The differential is subtracted from the scale value

• The storage and transport temperature

corresponds to the pressure switch body

admissible temperature

ELECTRIC SPECIFICATIONSRATED INSULATION VOLTAGE Ui 415V~

CONTINUOUS DUTY RATED CURRENT lth 16A

RATED OPERATING CURRENT IE:

220V~ 380/415V~

RESISTANCE LOAD AC-1 — 10A

INDUCTIVE LOAD AC-3 — 6A

DIRECT CURRENT DC-13 0,2A —

• Sensitive element with stainless steel diaphragm

• Metal frame

• Shock-proof thermoplastic cover

• Compliance with standards CEI EN 60947-4-1

* The differential is subtracted from the Range value

• The storage and transport temperature

corresponds to the pressure switch body admissible

temperature

ELECTRIC SPECIFICATIONSRATED INSULATION VOLTAGE Ui 415V~

CONTINUOUS DUTY RATED CURRENT lth 16A

RATED OPERATING CURRENT IE:

220V~ 380/415V~

RESISTANCE LOAD AC-1 — 16A

INDUCTIVE LOAD AC-3 — 6A

DIRECT CURRENT DC-13 0,2A —

• Sensitive element with stainless steel diaphragm

• Calibration screw designed to be sealed after testing.

• Metal frame, shock-proof thermoplastic cover

• Compliance with standards CEI EN 60947-4-1

• I.S.P.E.S.L. approval

* The differential is subtracted from the Range value

• The storage and transport temperature

corresponds to the pressure switch body

admissible temperature

ELECTRIC SPECIFICATIONSRATED INSULATION VOLTAGE Ui 415V~

CONTINUOUS DUTY RATED CURRENT lth 16A

RATED OPERATING CURRENT IE:

220V~ 380/415V~

RESISTANCE LOAD AC-1 — 16A

INDUCTIVE LOAD AC-3 — 6A

DIRECT CURRENT DC-13 0,2A —

RANGE DIFFERENTIAL *MAXIMUM PRESSURE

OF SENSITIVE ELEMENTCONNECTION

PRESSURE SWITCH BODY

ADMISSIBLE TEMPERATURE •PROTECTION

LEVEL

B12CN -0,2 TO 8 BAR 0,6 TO 3 BAR 9 BAR G 1/4 FEMALE -35 to 60°C IP40

B12DN 5 TO 16 BAR 1 TO 3,5 BAR 18 BAR G 1/4 FEMALE -35 to 60°C IP40

B12EN 8 TO 28 BAR 6 TO 29 BAR 29 BAR G 1/4 FEMALE -35 to 60°C IP40

B12CRN -0,2 TO 8 BAR 3 TO 9 BAR 9 BAR SAE 1/4" -35 to 60°C IP40

B12ERN 8 TO 28 BAR 6 TO 29 BAR 29 BAR SAE 1/4" -35 to 60°C IP40

RANGE DIFFERENTIAL *MAXIMUM PRESSURE

OF SENSITIVE ELEMENTCONNECTION

PRESSURE SWITCH BODY

ADMISSIBLE TEMPERATURE •PROTECTION

LEVEL

B12FN 12 TO 50 BAR 6 TO 15 BAR 60 BAR G 1/4 MALE -35 TO 60°C IP40

B12GN 25 TO 150 BAR 12 TO 40 BAR 180 BAR G 1/4 MALE -35 TO 60°C IP40

B12HN 60 TO 300 BAR 40 TO 80 BAR 350 BAR G 1/4 MALE -35 TO 60°C IP40

RANGE DIFFERENTIAL *MAXIMUM PRESSURE

OF SENSITIVE ELEMENTCONNECTION

PRESSURE SWITCH BODY

ADMISSIBLE TEMPERATURE •PROTECTION

LEVEL

B12FN 1 TO 5 BAR 0,6 BAR FIXED 9 BAR G 1/4 FEMALE -35 TO 60°C IP40

Page 80: CATALOGUE - Sentien Electronicssentien-electronics.com.au/catalogues/SENTIEN_CATALOGUE.pdf · for a better protection between bezel and metal panel. TECHNICAL DATA CONTROL RANGE -50÷120°C

80

SWITCHES

PRESSURE SWITCHES

PA-604 AIR DIFFERENTIAL PRESSURE SWITCH

TECHNICAL OVERVIEWThe PA-604 range are high sensitivity air differential pressure

switches for low differential pressure switching applications.

Suitable for use in air conditioning systems to provide an indication

of fan status or 'filter dirty' condition. The switching knob is mounted

under the cover to avoid tampering. The scale is individually laser

etched for high accuracy.

FEATURES• Snap fit cover

• Duct fixing kit included

• IP65 enclosure kit option

NOTEA duct fixing kit is supplied with the PA-930. It consists of 2m

of 6mm Dia. plastic tubing, 2 x pitot tubes, and 4 x fixing screws.

SPECIFICATION

OPERATING RANGES

TYPE ADJUSTMENT

RANGE

SWITCHING DIFFERENTIAL

(FACTORY SET)

PA-604-90 20 – 300PA 0.08 – 0.25 MBAR

PA-604-91 50 – 500PA 0.18 – 0.38 MBAR

PA-604-92 100 – 1000PA 0.28 – 0.67 MBAR

PA-604-94 500 – 2000PA 0.6 – 1.35 MBAR

MAX. OPERATING

PRESSURE5000PA 50 MBAR

PRESSURE

CONNECTIONS6MM ID PUSH-ON TUBING

ELECTRICAL RATING 5A (0.8A)230VAC

CONNECTIONS SCREW TERMINALS

DIMENSIONS 81MM DIA. X 52MM

HOUSING MATERIAL PLASTIC MOULDING

FIXING METAL MOUNTING BRACKET

PROTECTION IP54 (IP65 ENCLOSURE KIT OPTION)

AMBIENT RANGE -30C TO +85C

INSTALLATION

CATEGORYIEC 664 CATEGORY II

WEIGHT 160G

ORIGIN Switzerland

PRODUCT CODES

TYPE ADJUSTMENT

RANGE

SWITCHING DIFFERENTIAL

(FACTORY SET)

PA-604-90 20 – 300PA Air Differential Pressure Switch

PA-604-91 50 – 500PA Air Differential Pressure Switch

PA-604-92 100 – 1000PA Air Differential Pressure Switch

PA-604-94 500 – 2000PA Air Differential Pressure Switch

PA-604-90-IP65 200 – 300PAEnclosure kit with fitted

pressure switch

PA-604-91-IP65 50 – 500PAEnclosure kit with fitted

pressure switch

PA-604-92-IP65 100 – 1000PAEnclosure kit with fitted

pressure switch

PA-604-94-IP65 500 – 2000PAEnclosure kit with fitted

pressure switch

OPTIONAL ACCESSORIES

PA-DFK Duct fixing kit

PA-TEE Tee piece pack of 10

PA-TUBE-8MM PVC Tub, 8mm o/d, 30m rell

Page 81: CATALOGUE - Sentien Electronicssentien-electronics.com.au/catalogues/SENTIEN_CATALOGUE.pdf · for a better protection between bezel and metal panel. TECHNICAL DATA CONTROL RANGE -50÷120°C

81

1 Common

2 NC Contact

3 No Contact1

2

3

INSTALLATION1. The PA-604 should only be installed by a competent, suitably

trained technician, experienced in installation with hazardous

voltages. (>50Vac & <1000Vac or >75Vdc & 1500Vdc)

2. Ensure that all power is disconnected before carrying out any

work on the PA-604.

3. It is recommended that the unit be mounted vertically, with the

pressure ports pointing downwards (Fig.1). If the unit is mounted

horizontally (Fig.2) with the cover uppermost, the switching points

will be 11PA higher than the scale reading. If the unit is mounted

horizontally (Fig.3) with the cover facing downwards, the switching

points will be 11PA lower than the scale reading.

APPLICATIONIf the switch is to be used for filter status monitoring, the Pitot

tube ends should be cut square. If the switch is to be used for

fan status monitoring, the ends of the Pitot tube should be cut

at an angle of 45°.

SWITCHES

PRESSURE SWITCHES

PA-604 AIR DIFFERENTIAL PRESSURE SWITCH

FIGURE STATUS MONITORING

The switch can be used across a fan to provide proof of air

flow and hence fan status (Fig.4) shows how to connect the

High and Low pressure ports:

The switch can be used across a filter to provide dirty filter

status (Fig.5) shows the connections for this application.

CAUTIONThe PA-604 will be damaged if subjected to excessive pressure.

Do not test the unit by blowing into the inlet ports.

CONNECTIONS

Fig. 1 Fig. 2 Fig. 3

Fig. 4

Fig. 5

Page 82: CATALOGUE - Sentien Electronicssentien-electronics.com.au/catalogues/SENTIEN_CATALOGUE.pdf · for a better protection between bezel and metal panel. TECHNICAL DATA CONTROL RANGE -50÷120°C

82

SWITCHES

AUTOMATIC RESET PRESSURE CONTROL

ILPS/IHPS SERIES

SPECIFICATIONS

S.P.S.T – NORMALLY CLOSED CONTROL S.P.S.T – NORMALLY OPEN CONTROL S.P.S.T – NORMALLY CLOSED CONTROL

FEATURES• Snap-acting stainless steel, hermetically sealed sensor

• Corrosion resistant stainless steel crimp-ring

• Gold plated contacts are also available

• Wide variety of fittings and electrical connections

• Available in environmentally sealed or vented switch

• Excellent set-point repeatability/stability

APPLICATION• Residential and commercial air-conditioning, refrigeration

& heat pump applications.

• Service equipment including recovery and recycling machines.

OPERATIONAs the system pressure reaches above or below a preset value,

the snap-acting stainless steel diaphragm reverses its curvature,

opening or closing a set of electrical contacts trhough a transfer

pin. The control automatically resets when the pressure falls

within the factory preset pressure values.

DESIGN SPECIFICATIONS

CONFIGURATIONSPST or SPDT

NO or NC Contacts

FACTORY PRESET

PRESSURE RANGE

0 to 700 PSIG (0 to 48,2 Bar)

PROOF PRESSURE

250 PSIG (17,2 Bar) for set-point < 100 PSIG (<6,9 Bar)

600 PSIG (41,4 Bar) for set-point < 500 PSIG (<34,4 Bar)

800 PSIG (55,2 Bar) for set-point < 500 PSIG (<34,4 Bar)

BURST PRESSURE 5,000 PSI (344,8 Bar)

LIFE AT

RATED LOAD100,000 cycles

ELECTRICAL

RATING

24 VAC – 125 VA Pilot Duty

120/240 VAC – 375 VA Piloy Duty

120/240 VAC – 6 FLA, 36 LRA

DIELECTRIC

STRENGTH

750 Vrms Open Contacts

1,550 Vrms Terminals to Fitting

TEMPERATURE

RATING

AMBIENT -20 F to 176 F ( -30 C to 80 C)

FLUID -60 F to 275 F ( -50 C to 135 C )

WIRE LEADS

18 AWG, 600 V, 105 C, 1/32" insulated PVC

18 AWG, 600 V, 125 C, 1/16" insulated XLP

* Other leads are also available

CH C

HC

L

H(CUT-OUT ON HIGH) (CUT-OUT ON LOW) (CUT-OUT ON HIGH)

Page 83: CATALOGUE - Sentien Electronicssentien-electronics.com.au/catalogues/SENTIEN_CATALOGUE.pdf · for a better protection between bezel and metal panel. TECHNICAL DATA CONTROL RANGE -50÷120°C

83

SWITCHES

AUTOMATIC RESET PRESSURE CONTROL

ILPS/IHPS SERIES

ILSP / IHPS

Series

ILPS: NO

(Open on Pressure Rise)

IHPS: NO

(Open on Pressure Fall)

Auto ResetL Pressure Control

Close0 to 700 PSI

(O to 48,2 Bar)

TerminationSignifies Lead Length in inches00: 1/4" Male Spade Terminals06 to 72: 6" to 72" Wire Leads

Tolerance (In PSI)C: +/– 3D: +/– 4E: +/– 5F: +/– 6G: +/– 7H: +/– 8J: +/– 9K: +/– 10L: +/– 11M: +/– 12N: +/– 13P: +/– 14R: +/– 15Y: +/– 20Z: +/– 30

Fittings0: 1/4" Female Flare with Deflator1: 1/8" Male Pipe Thread2: 1/4" Male Pipe Thread4: 1/4" Solder7: 3/32" Copper Capillary Tube

LMT C180

Open0 to 700 PSI

(O to 48,2 Bar)

LMT C

STANDARD MODELS

ITEM MODEL OPEN PSI (Bar) CLOSE PSI (Bar)

7007 ILPS-018-033C015E 3 +/-3 (0,2) 15 +/-3 (1,0)

7024 ILPS-018-007CO22E 7 +/-3 (0,5) 22 +/-5 (1,5)

7034 ILPS-018-010C025E 10 +/-3 (0,7) 25 +/-5 (1,7)

7048 ILPS-018-020C040E 20 +/-3 (1,4) 40 +/-5 (2,8)

7057 ILPS-018-025C050E 25 +/-3 (1,7) 50 +/-5 (3,5)

7063 ILPS-018-025C080E 25 +/-3 (1,7) 80 +/-5 (5,5)

7075 ILPS-018-040C080E 40 +/-3 (2,8) 80 +/-5 (5,5)

7215 IHPS-018-200K150K 200 +/-10 (14) 150 +/-10 (10)

7217 IHPS-018-250K150K 250 +/-10 (17) 150 +/-10 (10)

7221 IHPS-018-300K200K 300 +/-10 (21) 200 +/-10 (14)

7228 IHPS-018-350K250K 350 +/-10 (24) 250 +/-10 (17)

7241 IHPS-018-400K200K 400 +/-10 (27) 200 +/-10 (14)

7258 IHPS-018-425K350K 425 +/-10 (29) 350 +/-10 (24)

Page 84: CATALOGUE - Sentien Electronicssentien-electronics.com.au/catalogues/SENTIEN_CATALOGUE.pdf · for a better protection between bezel and metal panel. TECHNICAL DATA CONTROL RANGE -50÷120°C

84

SWITCHES

SELECTOR SWITCHES 22Φ/25Φ

NSS22 -S 2 11 G A 1 2 3 4 5 6

1. SERIES

NSS22 NON-ILLUMINANTED

NLS22 ILLUMINANTED

3. POSITION

2 2 POSITION

1 2 POSITION (SPRING RETURN)

3 3 POSITION

0 3 POSITION (SPRING RETURN)

2. TYPE

NSS22 NLS22

S NORMAL SHAFT S NORMAL SHAFT

L LONG SHAFT L LONG SHAFT

K KEY

5. CAP COLOUR

NSS22 NLS22

R RED R RED

G GREEN G GREEN

Y YELLOW Y YELLOW

B BLACK

MODEL DESIGNATION

NON-ILLUMINANTED AND ILLUMINANTED

NSS22-S2 NLS22-S2

2 Positions 90º

1 2

3 Positions 45º

10

2

2 Positions 90º(Spring Return)

1 2

3 Positions 45º(Spring Return)

10

2

6. VOLTAGE RATING

NLS22

A AC.DC 24V

E AC.DC 100~120V

I AC.DC 220~240V

4. CONTACT BLOCKS

10 1A 21 2A1B

01 1B 12 1A2B

11 1A1B 22 2A2B

20 2A 01 2B

Page 85: CATALOGUE - Sentien Electronicssentien-electronics.com.au/catalogues/SENTIEN_CATALOGUE.pdf · for a better protection between bezel and metal panel. TECHNICAL DATA CONTROL RANGE -50÷120°C

85

SWITCHES

SELECTOR SWITCHES 22Φ/25Φ

NON-ILLUMINANTED AND ILLUMINANTED

NSS22-S3

NSS22-L2

NSS22-L3

NSS22-K2

NLS22-S3

NLS22-L2

NLS22-L3

NSS22-K3

Page 86: CATALOGUE - Sentien Electronicssentien-electronics.com.au/catalogues/SENTIEN_CATALOGUE.pdf · for a better protection between bezel and metal panel. TECHNICAL DATA CONTROL RANGE -50÷120°C

86

TEMPERATURE CONTROLLERS

VT48206 FUZZY PID CONTROLLER

FEATURES

PANEL, DESCRIPTION & KEYS OPERATION

• T/C, RTC, Linear Input Selectable

• Fuzzy enhanced PID Control

• Auto / Manual Bumpless Transfer

• Universal Power Supply: 90~264VAC, 50/60Hz,

or DC/AC24V is also available for option

• Standard Model with 2 Alarm outputs

• Standby and Latch mode can be combined with

8 different alarm functions

• Ramp to set point and Soack functions, and Soft-start function

• Retransmission or RS485 communication (MODBUS RTU)

or 4~20mA remote-setpoint is available for option

SPECIFICATION

INPUT

Thermocouple (J, K, R, S, T, E, B, N, C type)

DIN Pt100Ω or JIS Pt100Ω

Linear (4~20mA, 0~50mV, 0~1V, 0~5V, 0~10V...)

ACCURACY± 1°C for Thermocouple Input

± 0.2°C for Pt100Ω ; ±3mV for Linear Input

SAMPLE TIME 0.5 sec.

CONTROL MODE

P.bond 0.0~300.0% F.S. for P control

Integral Time 0~3600 sec.

DeRIVATIVE Time 0~900 sec.

Hysteresis Range 0.0~200.0 or 0~2000

Cycle Time 0~100 sec.

CONTROL CYCLE

Relay Contact Output 15 sec.

Pulsed Voltage to drive SSR: 1 sec.

Continuous Voltage (Current) Output: 0 sec.

OUTPUT MODE

Relay Contact Output 10A/240VAC (Resistive Load)

Pulsed Voltage to drive (SSR) DC 0/24V (Min. 250 ohm)

Continuous Current Output 4~20mA (Max. 600 ohm)

Continuous Voltage Output 0~1V, 0~5V, 0~10V (Max. 600 ohm)

GENERAL

OPERATION

Rated Power Supply Voltage 90~264VAC, 50/60H ; DC 24V

Ambient Temperature 0~50°C

Ambient Humidity 0~90%

Power Consumption under 5VA

WIRING DIAGRAM

PANEL CUTOUT WIDTH HIGH DEPTH

(Unit:mm) 45+0.5 45+0.5 100

SYMBOL DESCRIPTION ALARM OUTPUT OPERATION

No Alarm Function Alarm Output OFF

PV High Alarm

PV Low Alarm

Deviation High Alarm

Deviation Low Alarm

Band High Alarm

Band Low Alarm

On-Timer

Off-Timer

Page 87: CATALOGUE - Sentien Electronicssentien-electronics.com.au/catalogues/SENTIEN_CATALOGUE.pdf · for a better protection between bezel and metal panel. TECHNICAL DATA CONTROL RANGE -50÷120°C

87

TEMPERATURE CONTROLLERS

VT48206 FUZZY PID CONTROLLER

ERROR MESSAGE AND TROUBLESHOOTING

LOCK SETTING / ALARM MODE (A1MD/AMD)

HOW TO ORDER

MESSAGE PROBABLE SOLUTION

1) Sensor Break Error2) Sensor not be connected

1) Replace Sensor2) Check the Sensor be connected correctly

1) Input Signal over the High Limit2) Incorrect Input Sensor Selection

1) Set a Higher Value to High Limit2) Check connecting Input & Set Correct TYPE

1) Input Signal below the Low Limit2) Incorrect Input Sensor Selection

1) Set a Lower Value to Low Limit2) Check connecting Input & Set Correct TYPE

KEYPAD

NO FUNCTION

1) Keypads be locked2) Keypads Defective

1) Change "Lock: Setting with proper Value2) Replace Keypads

NO HEAT

OR OUTPUT

1) No Heater Power or Fuse Open2) Defective or Incorrect Output used

1) Check Output wiring and fuse2) Replace Output Device

NO ANY DISPLAY1) No Power to Controller2) SMPS Failure

1) Check wiring for Power Source2) Replace SMPS

PV CHANGED

ABNORMALLY

1) Electromagnetic Interference (EMI) or Radio Frequency Interference (RFI) 1) Suppress arcing contacts in System to eliminate High Voltage Spike Sources. Separate Sensor & Controller wiring from "dirty: power lines. Ground Heaters.

DATA LOST 1) Fail to Enter Data to EEPROM 1) Replace EEPROM

A/D Converter Damage 1) Check for Outside Source of Damage (Ex: Transient Voltage Spikes)2) Unit must be repaired or replaced

MESSAGE PROBABLE

All Parameters are locked

Only SV is Adjustable

Only 1st Level is Adjustable

1st & 2nd Levels are Adjustable

1st, 2nd, 3rd Levels are Adjustable

All Parameters are Opened

1000=000, 1001=0001, 1010=00101011=0011, 1100=0100But Output 2 is Opened

MESSAGE PROBABLE

Normal Alarm Mode

Standby Mode when selected, in any Alarm Function presents an Alarm on power on. The alarm is enable only when the PV reach alarm set-point. Also known as "Startup Inhibit" and is useful for avoiding alarm trips during startup.

Latch mode. When selected, the alarm output and indicator latch as the alarm occurs. The alarm ouput and indicator will be energised even if the alarm condition has been cleared unless the power is shut off.

Standby and Latch Mode

Page 88: CATALOGUE - Sentien Electronicssentien-electronics.com.au/catalogues/SENTIEN_CATALOGUE.pdf · for a better protection between bezel and metal panel. TECHNICAL DATA CONTROL RANGE -50÷120°C

88

TEMPERATURE CONTROLLERS

SPECIFICATIONS

DISPLAY Within 0.2% of displayed value + 1 digit

SAMPLING TIME 250m

OUTPUT MODE

Relay Outout

Voltage Output

Linear Output

Motor Control Output

Others

Contact, SPDT, 3A/240Vac

Voltage Pulse, 20VDC/20mA

4~20mA, 0~5V, 0~10V, 1~5V, 2~10V

Proportional motor 3 wired close loop circuit control

1φSSR, 3φSSR, 1φSCR, 3φSCR

GERNERAL SPECIFICATIONS

Power Consumption

Ambient Temperature

Ambient Humidity

4VA

0°C ~ 50°C

50 ~ 85 % (Non-dew)

MICROPROCESSOR CONTROLLER

FY900 / FY800 / FY700 / FY600 / FY400 SERIES

PANEL CUTOUT (UNIT:MM)

HOW TO ORDER

• Multi range Imput (TC, RTD, mV, mA) each 14Bit Resolution

• Auto/Manual Operation & Fuzzy/PID Control

• E²PROM Non-volatile memory

• Self-Diagnosis Function and Data Lock Function

• Free Power Range AC85~265V/DC15~50V

• Duplex Output Mode (Heat/Cool), Auxiliary Output PV, SV Retransmission

• 17 Alarm modes available, & option up to 3 Alarm sets

• Implement Zero/Phase Control by trig SCR Module directly

• RS232 & RS485 communication

• 2 Patterns each 8 segments programming procedure available

• 2nd Input can be used in Remote-SV

MODEL NO. SIZE OUTLINE (WxH) A B C D

FY900 1/4 DIN 96.0 + 96.0 90.5 + 0.5 90.5 + 0.5 111 116

FY800 1/8 DIN 50.0 + 96.0 44.5 + 0.5 90.5 + 0.5 65 116

FY700 68x68mm 74.0 + 74.0 68.5 + 0.5 68.5 + 0.5 89 94

FY600 1/8 DIN 96.0 + 50.0 90.5 + 0.5 44.5 + 0.5 111 70

FY400 1/16 DIN 50.0 + 50.0 44.5 + 0.5 44.5 + 0.5 65 70

Page 89: CATALOGUE - Sentien Electronicssentien-electronics.com.au/catalogues/SENTIEN_CATALOGUE.pdf · for a better protection between bezel and metal panel. TECHNICAL DATA CONTROL RANGE -50÷120°C

89

TERMINALS

FEED-THROUGH TERMINALS

FEED-THROUGH TERMINALS

FEED-THROUGH TERMINALS

– SCREW CLAMP CONNECTION

– MATERIAL PA66

– RAIL MOUNT ON TS32/TS35

OR DIRECT MOUNTING

HT-2.5 HT-4 HT-10

QTY. P. PCK. (G/PCS) 1320/200 1100/100 1630/100

TERMINAL WIDTH 5.1mm 6.2mm 8.4mm

INSULATION STRIPPING LENGTH 7mm 11.5mm 12mm

CONDUCTOR

CROSS-SECTION

SOLID 0.2 – 4 0.2 – 6 0.2 – 10

STRANDED 0.2 – 2.5 0.2 – 4 0.2 – 10

AWG 22 – 12 22 – 10 22 – 8

ELECTRICAL RATINGS VOLTAGE V CURRENT A VOLTAGE V CURRENT A VOLTAGE V CURRENT A

VDE 750 26 750 34 750 55

DE 600 24 600 30 600 50

UL 600 20 600 30 600 50

END PLATE EP-4 EP-4 EP-4

CROSS-CONNECTION HT-2.5-47 HT-4-47 HT-10-47

END BRACKET HT-5 or HT-5N HT-5 or HT-5N HT-5 or HT-5N

COLOUR Grey, Pear Grey, Pear Grey, Pear

APPROVALS

FEED-THROUGH TERMINALS

FEED-THROUGH TERMINALS

– SCREW CLAMP CONNECTION

– MATERIAL: PA66

– RAIL MOUNT ON TS35

HT-4E HT-10E HT-16E

QTY. P. PCK. (G/PCS) 1540/50 1680/50 1072/20

TERMINAL WIDTH 9mm 6.2mm 8.4mm

INSULATION STRIPPING LENGTH 11.5mm 11.5mm 12mm

CONDUCTOR

CROSS-SECTION

SOLID 0.2 – 6 0.2 – 6 0.2 – 10

STRANDED 0.2 – 4 0.2 – 4 0.2 – 10

AWG 22-10 22-10 22-8

RATED SURGE VOLTAGE 8kV 8kV 12kV

CONTAMINATION CLASS 3 3 3

COLOUR Green/Yellow Green/Yellow Green/Yellow

APPROVALS

C US®

C US®

C US®

C US®

C US®

C US®

Page 90: CATALOGUE - Sentien Electronicssentien-electronics.com.au/catalogues/SENTIEN_CATALOGUE.pdf · for a better protection between bezel and metal panel. TECHNICAL DATA CONTROL RANGE -50÷120°C

90

TERMINALS

FEED-THROUGH TERMINALS

TERMINALS

FEED-THROUGH TERMINALS

– SPRING CLAMP CONNECTION

– MATERIAL: PA66

– RAIL MOUNT ON TS32/TS35

OR DIRECT MOUNTING

– END BRACKETS

– END PLATES

– MARKING MATERIAL

HTP-4 HT-2.5-4.7 HT-4-47

QTY. P. PCK. (G/PCS) 1140/100

TERMINAL WIDTH 6.2mm

INSULATION STRIPPING LENGTH 11.5mm

CONDUCTOR

CROSS-SECTION

SOLID 0.2 – 6 HTP-10-47 HTP-16-47

STRANDED 0.2 – 4

AWG 22 – 10

ELECTRICAL RATINGS VOLTAGE V CURRENT A

VDE 750 34

DE 600 32

UL 600 30

END PLATE EPP-4

END BRACKET HT-5 or HT-5N

COLOUR Grey, Pear

APPROVALS —

TERMINALS

HT-5 HT-2.5-01C HT-4-01C HT-35-47

HT-5N

EPF-1 EPP-4 EP-4 EP-16 EP-35

COLOUR BLUE, GREY

COLOUR PEAR, GREY

1~ 10

91~100

A~Z

PE

Page 91: CATALOGUE - Sentien Electronicssentien-electronics.com.au/catalogues/SENTIEN_CATALOGUE.pdf · for a better protection between bezel and metal panel. TECHNICAL DATA CONTROL RANGE -50÷120°C

91

FEED-THROUGH TERMINALS

TERMINALS

FEED-THROUGH TERMINALS

FEED-THROUGH TERMINALS

AND ASSEMBLIES

– SCREW CLAMP CONNECTION

– MATERIAL: PC

– RAIL MOUNT ON TS35

NHT-10 NHT-20 NHT-30

QTY. P. PCK. (G/PCS) 760/100 1060/100 1400/100

TERMINAL WIDTH 9mm 10.6mm 13.2mm

HEAT DEFLECTION °C 130°C 130°C 130°C

AWG 22 – 16 22 – 14 22 – 12

ELECTRICAL RATINGS VOLTAGE V CURRENT A VOLTAGE V CURRENT A VOLTAGE V CURRENT A

CE/CSA/UL 600 10 600 20 600 30

END PLATE NHT-10-02 NHT-10-02 NHT-10-02

COLOUR Black Black Black

APPROVALS

FEED-THROUGH TERMINALS

FEED-THROUGH TERMINALS

AND ASSEMBLIES

– SCREW CLAMP CONNECTION

– MATERIAL: PC

– RAIL MOUNT ON TS35

NHT-60 NHT-100 NHT-200

QTY. P. PCK. (G/PCS) 3170/88 4310/50 195/1

TERMINAL WIDTH 22.5mm 32mm 39.5mm

HEAT DEFLECTION °C 130°C 130°C 130°C

AWG 12 – 6 6 – 2 2 – 3/0

ELECTRICAL RATINGS VOLTAGE V CURRENT A VOLTAGE V CURRENT A VOLTAGE V CURRENT A

CE/CSA/UL 600 60 600 100 600 240

POLE 1P 1P 1P

COLOUR Black Black Black

APPROVALS

FEED-THROUGH TERMINALS

FEED-THROUGH TERMINALS

AND ASSEMBLIES

– SCREW CLAMP CONNECTION

– MATERIAL: PC

– RAIL MOUNT ON TS35

NHT-2 NHT-3.5 NHT-8

QTY. P. PCK. (G/PCS) 21/1 35/1 60/1

TERMINAL WIDTH 25.8mm 35.5mm 43.5mm

HEAT DEFLECTION °C 130°C 130°C 130°C

AWG 22 – 14 22 – 12 12 – 8

ELECTRICAL RATINGS VOLTAGE V CURRENT A VOLTAGE V CURRENT A VOLTAGE V CURRENT A

CE/CSA/UL 600 20 600 30 600 50

POLE 3P 3P 3P

COLOUR Black Black Black

APPROVALS

Page 92: CATALOGUE - Sentien Electronicssentien-electronics.com.au/catalogues/SENTIEN_CATALOGUE.pdf · for a better protection between bezel and metal panel. TECHNICAL DATA CONTROL RANGE -50÷120°C

92

TERMINALS

FEED-THROUGH TERMINALS

TERMINALS

NHT-2-06A NHT-3.5-06A NHT-8-06A NHT-14-06A

NHT-22-06A NHT-38-06A NHT-200-06A NHT-10-06

TERMINALS

NHC-10-02 NHC-20-02 NHC-30-02 NHT-30-06

NHC-60-02 NHC-100-02 NHT-10-53 NHT-20-53 12D-53 18D-53

Page 93: CATALOGUE - Sentien Electronicssentien-electronics.com.au/catalogues/SENTIEN_CATALOGUE.pdf · for a better protection between bezel and metal panel. TECHNICAL DATA CONTROL RANGE -50÷120°C

93

THERMOCOUPLE & RTD PROBES

THERMOCOUPLE & RTD PROBES

ORDERING GUIDE

We offer a variety of Thermocouple

& RTD Probes as custom sizes.

Welcome custom sketches for

consulting price and availability.

Fig. 1 RTD Element

Fig. 2 Probe Head &

Terminal Block

Fig. 3 Leads Wire

Fig. 4 Thermowell & Fitting

Fig. 1 Fig. 2 Fig. 3 Fig. 4

Page 94: CATALOGUE - Sentien Electronicssentien-electronics.com.au/catalogues/SENTIEN_CATALOGUE.pdf · for a better protection between bezel and metal panel. TECHNICAL DATA CONTROL RANGE -50÷120°C

94

TIMERS

MDUV 480 – UNIVERSAL TIMERS

FEATURES

SPECIFICATIONS

ORDER NUMBER

• All Solid State, no moving contacts.

• Operating voltage 19 – 299V AC or DC

• 0.1 to 8 minutes time adjustable by knob with dial

• Digital Timing Circuit

• Good Repeat Accuracy

• Two Terminal Series Connection

• Epoxy Encapsulated

TIME

RANGE 0.1 to 8min (Knob adjustable with dial)

REPEAT ACCURACY ± 2% (Under fixed conditions)

RECYCLE TIME 40mx Max. (After timing)

VOLTAGE

RANGE 19 to 288 Volts AC or DC

FREQUENCY DC or AC 60Hz/50Hz

OUTPUT

TYPE Solid State

MAX. CURRENT 1 Amp steady state, 10 Amps in-rush at 55°C

MIN. CURRENT 40 mA

VOLTAGE DROP Typical 2.5V at 1 Amp current

PROTECTION

INTERNAL VARISTOR

MIN. 1500 Vrms Dielectric Breakdown

MAX. 100MΩ insulation resistance (Test at 500VDC)

TEMPERATURE

OPERATING TEMP. -20°C to +70°C

STORAGE TEMP. -30°C to +80°C

Upon application of input voltage, the load de-energizes ad the time

delay is initiated. At the end of the delay time, the load energizes.

Reset is accomplished by removing input voltage.

M D U V 480 1 2 3 4 5

1. OPERATION MODE M – Delay On Make

2. CIRCUIT TYPE D – Digital Circuit

3. OPERATING VOLTAGE U – Universal Range 19 - 288V

4. ADJUSTMENT TYPE V – Variable Resistor Built-in

5. TIME RANGE 480 – Delay Time Max. 480 Sec.

DIMENSIONS

CONNECTION

TIMING DIAGRAM

Page 95: CATALOGUE - Sentien Electronicssentien-electronics.com.au/catalogues/SENTIEN_CATALOGUE.pdf · for a better protection between bezel and metal panel. TECHNICAL DATA CONTROL RANGE -50÷120°C

95

TIMERS

DELAY ON BREAK TIMERS

DELAY ON BREAK TIMERS

APPLICATION TIMING DIAGRAM MODE OF OPERATION

"Anti-short Cycle"

"OFF delay on break"

Helps to protect air conditioning,

refrigeration and heat pump equiptment

from damage which may be caused by the

rapid short cycling of compressors.

Upon application of power, the load is energized.

When the thermostat or other switch opens, or

there is a loss of power, the load is de-energized

and the delay period begins. The compressor will

not start again during the delay period. Restart

occurs after the delay period.

ICM CONTROL SERIES FEATURES/APPLICATIONS SPEC REPLACES

ICM200

ICM200F

ICM201

ICM201F

• Higher 1.5 Amp Rating

• Compressor lockout/anti-shock

cycle timer

• Helps to protect compressors from

damage caused by rapid short cycling

• Simple, 2-wire hookup

• Compact, 2" x 2" package

• F suffix denotes 6" wire leads

(shown at left)

• ICM200 has 3min. delay

• ICM201 has 5min. delay

• 18 – 30VAC

• 1.5 Amps

• 15 Amp inrush

• 3 or 5min. fixed

time delays

• Voltage Drop:

3.5V Typical

4.5V Max

• Frequency:

50/60Hz

• Requires 40mA

holding current

• Diversified:

ASC-500, 501

ASC-502

ASC-505-5

• Gemline:

IC321

IC322

• Watsco:

EAC-500

EAC-501-180-W

EAC-501-300-W

ICM203

ICM203F

• Universal Voltage Operation

• Higher 1.5 Amp power rating

• Compressor lockout/anti-shock

cycle timer

• Helps to protect compressors from

damage caused by rapid short cycling

• Simple, 2-wire hookup

• Compact, 2" x 2" package

• F suffix denotes 6" wire leads

• Works with anitcipator-type thermostats

• 18 – 240VAC

• 1.5 Amps

• 15 Amp inrush

• Knob-adjustable

delays .03-10 min.

(1.8 – 600 sec.)

• Voltage Drop:

3.5V Typical

4.5V Max

• Frequency:

50/60Hz

• Requires 40mA

holding current

• Diversified:

ASC-500, 501

ASC-502

ASC-505-5

• Gemline:

IC320

• Mars:

32392

• Robertshaw:

3310-072

• Supco:

TD-73

• Watsco:

EAC-500

EAC-501-180-W

EAC-501-300-W

DELAY ON BREAK TIMERS - ULTRA LOW COST

ICM CONTROL SERIES FEATURES/APPLICATIONS SPEC REPLACES

ICM207

ICM208

ICM209

• Universal Voltage Operation

• Higher Voltage Operation

• Help prevent scroll compressor reversal

• Fast response time: 16 ms.

• Eliminates relay chatter due to

thermostat bouncing or tampering

• Works with anitcipator-type thermostats

• Compact, epoxy-encapsulated package

• ICM207 has 3 min. delay

• ICM208 has 5 min. delay

• ICM209 has 10 min. adjustable delay

• 18 – 240VAC

• 1 Amps

• 1 Amp inrush

• 3 or 5min. fixed

or 10min.

• Voltage Drop:

2.5V at 1 Amp

• Frequency:

50/60Hz

• Requires 40mA

holding current

N/A

Page 96: CATALOGUE - Sentien Electronicssentien-electronics.com.au/catalogues/SENTIEN_CATALOGUE.pdf · for a better protection between bezel and metal panel. TECHNICAL DATA CONTROL RANGE -50÷120°C

96

BYPASS TIMERS

TIMERS

BYPASS TIMERS

APPLICATION TIMING DIAGRAM MODE OF OPERATION

"ON delay interval timer"

"Normally closed delay on make"

Designed to bypass a control or device

during startup. Typically used to bypass a

low pressure switch during compressor

startup or to bypass an oil pressure

switch upon startup. Helps to eliminate

nuisance lockouts.

With power applied to the input, the load

energizes immediately and remains energized

for the length of the time delay, regardless of

the state of the switch being bypassed. At the

end of the time delay the condition of the load

is determined by the state of the switch.

ICM CONTROL SERIES FEATURES/APPLICATIONS SPEC REPLACES

ICM175

• Designed to bypass a low pressure switch

or other device during startup

• Ideal for low ambient startups

• Integral component for "winter start" kits

• Helps to reduce nuisance lockouts

• Universal AC Voltage operation

• Knob-adjustable time delays

• Epoxy-encapsulated circuitry

• 18 – 30VAC

• 1 Amps

• 10 Amp inrush

• Knob-adjustable

time delays:

10 – 1000 seconds

• Mars:

32395

• Supco:

TDP68

ICM305

(minutes)

ICM306

(seconds)

• Reliable duty cucle timer ideally suited

for defrost applications

• Suitable for process equipment or

applications requiring intermittent delays

• Switch-settable time delays

• Digital timing accuracy

• Reliable solid state output

• Epoxy-encapsulated for greater reliablility

• ICM305: Time delay in minutes

• ICM306: Time delay in seconds

• ON-Time starts with power up, OFF-Time

initiates after ON-Time, Timing cycle

repeats until power loss

• 18 – 240VAC

• 1 Amps

• 10 Amp inrush

Time Delay: ICM305

• Switch-settable

from: 1 – 1,023 min.

in 1 min. intervals

Time Delay: ICM306

• Switch-settable

from: 1 – 1,023 min.

in 1 min. intervals

N/A

Page 97: CATALOGUE - Sentien Electronicssentien-electronics.com.au/catalogues/SENTIEN_CATALOGUE.pdf · for a better protection between bezel and metal panel. TECHNICAL DATA CONTROL RANGE -50÷120°C

97

DELAY ON BREAK

TIMERS

SERIES TBPS

MODE OF OPERATION

When the normally open initial contact closes, the delay is energized.

The load stays energized as long as the initial contact remains closed.

When the initial switch opens, the Delay Off period begins. When the time

delay period is complete, the load is de-energized. If the initial contact closes

during the OFF delay period, the load remains energized and the time delay

resets to zero.

The timer features three OFF time delay ranges (from 0.1 to 1,000 seconds)

available in any of four different moethods of adjustment.

• Universal Voltage

• Fixed or adjustable time delays up to 1,000 seconds

• Totally sold state circuitry

• Epoxy encapsulated

When the normally open initial contact closes, the delay is energized.

The load stays energized as long as the initial contact remains closed.

When the initial switch opens, the Delay Off period begins. When the

time delay period is complete, the load is de-energized. If the initial

contact closes during the OFF delay period, the load remains energized

and the time delay resets to zero.

TBPS - 00A 2 Y 02 1 2 3 4 5 5. TIME RANGE

01 0.1 to 10 Seconds

02 1 to 100 Seconds

03 10 to 1,000 Seconds

1.

Series

3. CONTROL METHOD

1 Fixed Time External

2 Local Adjust

5 Remote Adjust

9 Fixed Internal2. INPUT VOLTAGE

00A = 18 – 240 VAC

4. TOLERANCE

Y = ±10%

ORDERING INFORMATION

MODEL DESIGNATION

INPUT

NORMINAL VOLTAGE 18 – 240 VAC

TOLERANCE +/-20%

FREQUENCY 50/60 Hz

MAXIMUM ALLOWABLE DC RIPPLE

VOLTAGE20%

POWER CONSUMPTION .5 Watts Maximum

OUTPUT

TYPE Triac

RATING1.0 Amp max, 20 mA min,

10 Amp inrush

VOLTAGE DROP 2.5 Volts max. @ 1.0 Amp

LEAKAGE CURRENT 5 mA max. @ 240 VAc

TIME DELAYS

TYPE Fixed internal, Fixed External, Local

Adjust, Remote Adjust

RANGEFixed up to 1,000 seconds adjustable

0.1-10, 1-100, 10-1000 seconds

RESET TIME DURING ON OR

OFF PERIOD100 milliseconds

REPEAT ACCURACY +/-.5%

FIXED TIME TOLERANCE +/-10%

TIME DELAY VS. TEMP. AND VOLTAGE +/-5% maximum

ENVIRONMENTAL

OPERATING TEMPERATURE -40°C to +75°C

STORAGE TEMPERATURE -40°C to +85°C

TRANSIENT PROTECTION

+/-1,400 VOLTS FOR 100 MICROSECONDS

Page 98: CATALOGUE - Sentien Electronicssentien-electronics.com.au/catalogues/SENTIEN_CATALOGUE.pdf · for a better protection between bezel and metal panel. TECHNICAL DATA CONTROL RANGE -50÷120°C

98

AH3- SERIES

TIMERS

FEATURES

CONNECTION DIAGRAM OPERATION TIME CHART

• Two LED's provides status inducation, for power ON and time UP.

• Wide variety of type-14 ranges (0.1 sec. to 10 hrs.)

• Standard surface mounting could be easily converted into flush

mounting by adding a special adaptor. (Type Y-40)

TYPE AH3-� AH3-� +(Y-40) Adaptor

W x H x D mm (Dimensions) 40 x 50 x 58 45 x 54 x 59

AVAILABLE TYPES

TYPE

MOUNTING Surface Mounting AH3-1 AH3-2 AH3-3

Flushing Mounting Y-40 Y-40 Y-40

CONTROL

OUTPUT

Time-Limit Contact SPDT (SA) DPDT (SA) SPDT (SA)

Instantaneous Contact — — SPST-NO (SA)

CONNECTION & TIMING CHART 1. 2. 3.

TIME RANGE

RATED TIME TIME SETTING RANGE OPERATING VOLTAGE

1S 0.1S ~ 1S

3S 0.3S ~ 3S

6S 0.6S ~ 6S

10S 1S ~ 10S DC 12V

30S 3S ~ 30S DC 24V

60S 6S ~ 60S AC 110V 50/60Hz

3M 10S ~ 100S

6M 20S ~ 6M AC 120V 50/60Hz

10M 30S ~ 10M

30M 2M ~ 30M AC 220V 50/60Hz

60M 3M ~ 60M

3H 10M ~ 3H AC 240V 50/60Hz

6H 20M ~ 6H

10H 30M ~ 10H

SPECIFICATIONS

OPERATING VOLTAGEAC: 85 – 110% of rated voltage

DC: 80 – 110% of rated voltage

RATED VOLTAGEAC: 110V, 220V, 240V, 50/60Hz

DC: 12V, 24V

CONSUMED POWER About 2VA for AC: About 2W for DC

CONTROL METHOD Time-Limit Operating Self-resetting

CONTACT RATING AC: 120V 5.A. (p.f. = 1)

AMBIENT TEMP -10°C ~ +55°C

AMBIENT HUMIDITY 45 ~ 85%

CHARACTERISTICS

REPEAT ACCURACY Less than ± 1% of full scale

EFFECT OF VOLTAGE Less than ± 1%

EFFECT OF

TEMPERATURELess than ± 2% at 20°C

SETTING ACCURACY Less than ± 10% of full scale

RESET TIME 0.1, Less than 0.1 Sec.

INSULATION

RESISTANCEOver 50MΩ (DC500V)

DIELECTRIC AC 2000V one Min.

WEIGHT Approximately 160g

SHOCK RESISTANCE Incorrect Operate 10G

LIFEMECHANICAL 5,000,000 Operations

ELECTRICAL 100,000 Operations at rated load

VIBRATION RESIS-

TANCE

Incorrect Operate 10.55Hz 0.5mm

Durability 10.55Hz 0.5mm

AH3-1

AH3-2

AH3-3

Page 99: CATALOGUE - Sentien Electronicssentien-electronics.com.au/catalogues/SENTIEN_CATALOGUE.pdf · for a better protection between bezel and metal panel. TECHNICAL DATA CONTROL RANGE -50÷120°C

99

TM/TR SERIES

TIMERS

FEATURES

FEATURES

DIAGRAMS

1. Manual Override

2. Easily Programmable

3. Captive pins. Many switching possibilities.

96 pins on daily dials.

4. Mark for time setting and programme reading

5. Time can be setting manually

• TM35-A 110V

• TM35-B 230V

• TM35-C 240V

DIAL

FREQUENCY SELECTOR

ARROW (TURNING DIRECTION)

PRESENT TIME (HOUR)

SETTING PIN (ON POSITION)

SETTING PIN (OFF POSITION)

POWER INDICATOR

TERMINAL COVER

POWER TERMINAL

CASE

PRESENT TIME

PRESENT CONTROL KNOB

MINUTE CONTROL KNOB

MANUAL SWITCH

LOAD TERMINAL

GROUND TERMINAL

CIRCUIT DIAGRAM

CIRCUIT DIAGRAM

ELECTRICMAGNETIC SWITCH ELECTRICMAGNETIC SWITCH

NOTE BEFORE OPERATING, TAKE OFF

ALL PROTECTIVE WIRE OF ELECTRO

MAGNETIC SWITCH SHOWN WITH

DOTTED LINES IN DIAGRAM.

Page 100: CATALOGUE - Sentien Electronicssentien-electronics.com.au/catalogues/SENTIEN_CATALOGUE.pdf · for a better protection between bezel and metal panel. TECHNICAL DATA CONTROL RANGE -50÷120°C

100

DIGITAL TIMERS FOR DIN RAIL OR SURFACE MOUNTING

TIMERS

FEATURES

USE• Switching Timer Module where daily or weekly

programming is required, or for general use.

INSTALLATION AND OPERATION• Programming System using 7 control push buttons and

1 RESET button.

• Liquid Crystal Display showing the time, and the day of the week

• PROGRAM CAPACITY 8 ON and 8 OFF. Block program capacity

• 1 Minute between operations.

• Program check facility.

• Manual override capacity in Auto mode.

• 100 hrs back-up battery

• DIN rail EN50022-3 DIN46277-3 mounting.

TECHNICAL FEATURES• Compact Modular casing (2 moduls) in insulated thermoplastic

material, suitable for side by side mounting.

• Transparent cover to protect control buttons.

• 16 memories available. (8 ON-8 OFF).

• Timing accuracy ±1 min/month.

• II protection cclass to EN60335.

HOMOLOGATION AND STANDARD• Homologation TÜV.

ELECTRICAL FEATURES• Supply voltage 220V-250V 50/60Hz.

• Power consumption 4,4W.

• Electromagnetic out put relay with volt free contacts.

• 1,2Vdc NiMH battery.

• Out put contacts rated at 16(8)A 250V.

TYPE PROGRAMMINGAMBIENT

TEMPERATURE °CVOLTAGE

PROTECTION

DEGREEN° DEGREE WEIGHT BOX

W04C DAILY WEEKLY -10 TO 40 230V~250V 50/60HZ IP30 2 0.13

Page 101: CATALOGUE - Sentien Electronicssentien-electronics.com.au/catalogues/SENTIEN_CATALOGUE.pdf · for a better protection between bezel and metal panel. TECHNICAL DATA CONTROL RANGE -50÷120°C

101

THERMOSTATS

ELECTRONIC DE-ICE THERMOSTAT

SOLID STATE DEFROST CONTROL

The ICM315 is a reliable, solid state replacement for E15-type controls.

It uses a thermistor-type probe as opposed to the unstable bulb-type

sensors used with E15 controls. The ntc-type probe of the ICM315

is less susceptible to breakage. Unlike E15 controls, the ICM315 is

not "position-sensitive" and therfore not susceptible to "re-initiation

phenomenon" which can cause damage due to system short-cycling.

The ICM315 features a built-in clip for easier mounting.

FEATURES• Solid State reliability...replaces unstable bulb-type sensors. Less

susceptible to breakage.

• Ultra Low Cost...without compromised performance.

• "No re-initiation phenomenon"...ICM315 is not position-sensitive.

• Quick, easy mounting... features built-in clip.

• ORDERING INFORMATION Order ICM P/N: ICM315.

SPECIFICATIONS

INPUT

• VOLTAGE 24, 120 or 240 VAC.

• FREQUENCY 50/60Hz

• POWER CONSUMPTION 1 watt max.

OUTPUT

• TYPE Relay

• FORM SPDT, n.o. : 20 Amps @ 240 VAC

n.c. : 10 Amps @ 240 VAC

INPUT

• DEFROST TIME Fixed at 10min. +/-20%

• INTERVAL TIME BETWEEN DEFROSTS 30/45/90 pin-selectable

• TEST TIME Short across DEF terminals reduces test time by 256X

MECHANICAL

• MOUNTING Surface mount using (4) #6 or #8 screws\

MODE OF OPERATIONThe ICM315 provides a selectable time interval (30,45,90 min.)

between 10 min. defrost cycles. Upon application of power the timing

sequence begins with the delay period first, and the 10 min. defrost

period second.

When the thermistor senses a temperature of 28°F of lower, the

defrost board will be controlled by its internal timer. The relay will be

energized every 30, 45 or 90 minutes based opon the post selected.

If, during the 10 min. defrost period, the temperature rises of 55°F

or greater, the defrost period will terminate. If this condition does

not occur, the defrost period will complete and the entire sequence

will repeat.

The on-board relay (K1) will be energized only during the 10 min.

defrost period.

CONNECTION DIAGRAM

Page 102: CATALOGUE - Sentien Electronicssentien-electronics.com.au/catalogues/SENTIEN_CATALOGUE.pdf · for a better protection between bezel and metal panel. TECHNICAL DATA CONTROL RANGE -50÷120°C

102

THERMOSTATS

DIGITAL ROOM THERMOSTAT

NHY-RTC100 MICROPROCESSOR CONTROL

WIRING DIAGRAM

FEATURES• Easy to Install.

• Contemporary Design for Simple Operation.

• Integral Design: All Outputs Built in

• Reverse Cycle and Heat Pump Application

• Heating and Cooling Manual/Auto changeover

• Accurate Temperature Control +/-1°C

• Displays Room and Setting Temperature

• 0.5 hour to 24 hour Delay Start or Stop Timer

• Temperature Range 15°C to 30°C

• Confort Sleeping Mode for Night Temperature

• Tamper-proof Settings

• Manual or Auto Fan

• Optional Remote Sensor

• Standard Wall Mounting Box

Page 103: CATALOGUE - Sentien Electronicssentien-electronics.com.au/catalogues/SENTIEN_CATALOGUE.pdf · for a better protection between bezel and metal panel. TECHNICAL DATA CONTROL RANGE -50÷120°C

103

THERMOSTATS

ROOM THERMOSTATS

ROOM THERMOSTAT WITH VAPOR TENSION

ELECTRONIC ROOM THERMOSTAT

3 SPEEDS ELECTRONIC ROOM THERMOSTAT FOR FAN-COILS

• Sensitive element with electrically

welded stainless steel capsule

containing saturated vapour.

• Vapour pressure operation.

• Base, cover and knob in thermoplastic.

• Connection to the user with only 2 wires.

• Numerous signal and control variants.

• Compliance with standards

CEI EN 60730-1

• Contact rating: 10(2.5)A 250 VAC.

• Sensitive element with semiconductor sensor.

• Wall mounting.

• Double Insulation.

• SUMMER-WINTER-OFF switch for controlling

heating or air conditioning systems.

• Red LED to indicate relay cut-in, to request

heating (switch in winter position) or cooling

(switch in summer position).

• Compliance with standards CEI EN 60730-1

and second parts.

• Maximum dissipated power 1VA.

• Contact rating 6(1.5)A 250 V~.

• Voltage free switching contact.

• Sensitive element with semiconductor sensor.

• Wall mounting.

• Double Insulation.

• SUMMER-WINTER-OFF switch for controlling

heating or air conditioning systems.

• Manual switch for selecting one of the three

Fan-coil speeds.

• Compliance with standards CEI EN 60730-1

and second parts.

• Power Supply 230V ~ 50Hz

• Maximum dissipated power 1VA.

• Contact rating 6(1.5)A 250 V~.

SPECIFICATIONS

RANGE DIFFERENTIAL * ADMISSIBLE

THERMOSTAT BODY

TEMPERATURE •

MAXIMUM AMBIENT

TEMPERATURE

PROTECTION LEVEL

C16 10 to 30°C 0,8 K -10 to 50°C 45°C IP20 (normal pollution

TC16

Frame for mounting on: round box 60mm, screw fixing

round box with clips (not supplied)

round box distance between centres 75mm

* The differential is subtracted from the Range value. The differential values refer to a thermal gradient of 4K/hour in air.

• The stroage and transport temperature corresponds to the thermostat body admissible temperature.

CONTROL AND SIGNALLING VARIANTS

DESCRIPTION

C16L With Pilot Light

C16I With "ON-OFF" Switch

C16IL With "ON-OFF" Switch and Pilot Light

C16EH With "Summer-Winter" Switch

C16EHL With "Summer-Winter" Switch Switch and Pilot LIght

SPECIFICATIONS

RANGE DIFFERENTIAL * POWER SUPLY MAXIMUM AMBIENT

TEMPERATURE

PROTECTION LEVEL

C16 6 to 30°C ±0,5 K 230V - 50Hz 45°C IP20 (normal pollution

* The differential values refer to a thermal gradient of 4K/hour in air.

SPECIFICATIONS

RANGE DIFFERENTIAL * POWER SUPLY MAXIMUM AMBIENT

TEMPERATURE

PROTECTION LEVEL

C16 6 to 30°C ±0,5 K 230V - 50Hz 45°C IP20 (normal pollution

* The differential values refer to a thermal gradient of 4K/hour in air.

Page 104: CATALOGUE - Sentien Electronicssentien-electronics.com.au/catalogues/SENTIEN_CATALOGUE.pdf · for a better protection between bezel and metal panel. TECHNICAL DATA CONTROL RANGE -50÷120°C

104

• Liquid expansion operation.

• Wall mounting of thermostat body.

• The bulb with capillary can be mounted at a

distance and provided with seal caps or copper

sheath with Gc 1/2 connection.

• Sensitive element with stainless steel diaphragm.

• Copper bulb and capillary, tinned for type C04C

and C04D.

• Base, cover and knob in shock-proof

self-extinguishing thermoplastic V0.

• Compliance with standards CEI EN 60947-5-1.

• IP65 waterproof execution C04..Y.

THERMOSTATS

TEMPERATURE CONTROLS

THERMOSTAT WITH CAPILLARY AND BULB FOR REMOTE MOUNTING

POSITIVE SAFETLY SHUTDOWN IMMERSION THERMOSTAT

POSITIVE SAFETY SHUTDOWN AND REGULATION IMMERSION BITHERMOSTAT, FOR DIRECT MOUNTING

SPECIFICATIONS

RANGE DIFFERENTIAL * CALIBRATION

ACCURACY

ADMISSIBLE

THERMOSTAT BODY

TEMPERATURE •

MAXIMUM BULB

TEMPERATURE

CAPILLARY

LENGTH

PROTECTION

LEVEL

C04A2 10 to 90°C 6 ± 1 K ±3°C -35 to 120°C 150°C 1 mt IP40

C04B2 50 to 300°C 8 ± 2 K ±3°C -35 to 120°C 310°C 1,5 mt IP40

C04C2 -20 to 40°C 2 ± 0,5 K ±2°C -35 to 60°C 80°C 1,5 mt IP40

C04D2 -35 to 20°C 2 ± 0,5 K ±2°C -35 to 50°C 80°C 1,5 mt IP40

C04E2 40 to 120°C 6 ± 2 K ±3°C -35 to 120°C 150°C 1 mt IP40

* The differential is subtracted from the Range value. The differential values refer to a thermal gradient of 1K/hour in liquid and 5K/hour in air.

• The storage and transport temperature corresponds to the thermostat body admissible temperature.

SPECIFICATIONS

CUT-OFF

ACTION

CUT-OFF

TOLERANCE

ADMISSIBLE THERMOSTAT BODY

TEMPERATURE •

MAXIMUM BULB

TEMPERATURE

PROTECTION LEVEL

C06A2M 100°C ±0 / - 6°C -35 to 120°C 130°C IP40

C06B2M 90°C ±0 / - 6°C -35 to 120°C 130°C IP40

• The storage and transport temperature corresponds to the thermostat body admissible temperature.

SPECIFICATIONS

CUT-OFF

ACTION

DIFFERENTIAL * CUT-OFF

TOLERANCE

ADMISSIBLE THERMOSTAT BODY

TEMPERATURE •

MAXIMUM BULB

TEMPERATURE

PROTECTION

LEVEL

C06A2M 10 to 90°C 8 K ±0 / - 6°C -35 to 120°C 130°C IP40

* The differential is subtracted from the Range value. The differential values refer to a thermal gradient of 1K/hour.

• The storage and transport temperature corresponds to the thermostat body admissible temperature.

ELECTRIC SPECIFICATIONS

Rated Insulation Voltage Ui 380V~

Continuious Duty Rated Current Ith 15A

Rated Operating Current ie: 220V~ 250V~ 380V~

Resistive Load AC-12 — 10A 10A

Inductive Load AC-15 — 2.5A 1.5A

Direct Current DC-13 0.2A — —

• Liquid expansion operation.

• Direct immersion mounting of the bulb via

threaded sheath Gc 1/2 (included).

• Sensitive element with stainless steel diaphragm.

• Copper bulb and capillary.

• Copper sheath with Gc 1/2PN10 connection

• Base and cover in shock-proof

self-extinguishing thermoplastic V0.

• I.S.P.E.L approval for C06A2M.

• Compliance with standards CEI EN 60947-5-1.

• Compliance with the requirements

established in chapter R.3.B. of the applicative

technical specifications of Ministerial Decree

1 December 1975.

• Liquid expansion operation.

• Direct immersion mounting of the bulb via

threaded sheath Gc 1/2 (included).

• The bi-thermostat is composed of a C03A and

a C06AM in a single cover and one sheath.

• Sensitive element with stainless steel diaphragm.

• Copper bulb and capillary.

• Copper sheath with Gc 1/2PN10 connection.

• Base and cover in shock-proof

self-extinguishing thermoplastic V0.

• I.S.P.E.L approval.

• Compliance with standards CEI EN 60947-5-1.

• Compliance with the requirements

established in chapter R.3.B. of the applicative

technical specifications of Ministerial Decree

1 December 1975.

ELECTRIC SPECIFICATIONS

Rated Insulation Voltage Ui 380V~

Continuious Duty Rated Current Ith 15A

Rated Operating Current ie: 220V~ 250V~ 380V~

Resistive Load AC-12 — 10A 10A

Inductive Load AC-15 — 2.5A 1.5A

Direct Current DC-13 0.2A — —

ELECTRIC SPECIFICATIONS

Rated Insulation Voltage Ui 380V~

Continuious Duty Rated Current Ith 15A

Rated Operating Current ie: 220V~ 250V~ 380V~

Resistive Load AC-12 — 10A 10A

Inductive Load AC-15 — 2.5A 1.5A

Direct Current DC-13 0.2A — —

Page 105: CATALOGUE - Sentien Electronicssentien-electronics.com.au/catalogues/SENTIEN_CATALOGUE.pdf · for a better protection between bezel and metal panel. TECHNICAL DATA CONTROL RANGE -50÷120°C

105

ADJUSTABLE THERMOSTAT

THERMOSTATS

TR2

OVERALL DIMENSIONS

Thermostat single pole liquid filled sensing bulb and bellows, operating

switch contacts for the automatic adjustment of the temperture of boilers,

electric, radiators, overns, washing machines, dish washers, etc, besides

different applications in the field of home and industrial air conditioning

and house hold appliances. Sensing bulb may be supplied with pocket

or gland for liquid sealing.

TECHNICAL DATA

CONTACTS Ag 1000/1000

CONTACTS RATING15 (2.5)A 250V~

10 A 380V~

CUT-OFF CONTACTS FOR TEMPERATURE RAISING

OR SWITCHING CONTACT–––

MAX. HEAD TEMPERATURE 150°C

CAPILLARY LENGTH 1000 mm

MIN. CAPILLARY BENDING RADIUS 5 mm

NOISE LEVEL VDE cl. N

NUMBER OF AUTOMATIC CYCLES ll (100 000)

TEMPERATURE RATE OF CHANGE 1°K/min

RESISTANCE TO TRACKING PTI 250 (KB 250)

STANDARD TYPES

CODE TEMP. RANGE TEMP. DIFFERENTIAL MAX. BULB TEMP. COPPER BULB CAPILLARY LENGTH AG/CD CONTACTS

540043 -30°C/+35°C Δt = 1,5° ± 0,5°K 65°C ø6 x 215 mm —

540030 0°C/40°C Δt = 2° ± 1°K 65°C ø9,5 x 95 mm —

540010 0°C/90°C Δt = 4° ± 1°K 150°C ø6,5 x 95 mm —

540168 0°C/120°C Δt = 4° ± 1°K 150°C ø6,5 x 95 mm —

540140 0°C/210°C Δt = 9° ± 2°K 270°C ø5 x 136 mm —

540020 0°C/300°C Δt = 10° ± 2°K 350°C ø3,5 x 195 mm —

541307 0°C/90°C Δt = 4° ± 1°K 150°C ø6,5 x 95 mm 1500 mm

540080 17,5°C/30,5°C Δt = 1,5° ± 0,5°K 65°C ø6,5 x 210 mm — Ag/Cd

Page 106: CATALOGUE - Sentien Electronicssentien-electronics.com.au/catalogues/SENTIEN_CATALOGUE.pdf · for a better protection between bezel and metal panel. TECHNICAL DATA CONTROL RANGE -50÷120°C

106

THERMOSTATS

THERMOSTAT FOR PANEL MOUNTING SERIES KMf-70; KMf-20

THERMOSTAT, M/R ADJUSTABLE

THERMOSTAT, M/R ADJUSTABLE

DETAILSPROTECTION IP 00

ARRANGEMENT TO DIN 3440 as

STB = Safety Temperature Limiter

STW (STB) = Safety Temperature Monitor

DVGW Approved to EU Gas Appliances Directive (90/386/EWG)

DESCRIPTIONThe panel-mounting thermostats Type KMf are suitable for controlling

and monitoring heating systems, boilers, heat exchangers and pumps

in heating, ventilating and air conditioning. The panel-mounting

thermostats are approved to DIN 3440.

The essential information for ordering is shown in the Technical data

with a grey background.

GERNERAL APPLICATION• Ovens and Furnances

• Laboratory and Climatic Cabinets

• Apparatus and Mechanicial Equipment

• Heating Boilers to DIN 4751

• Steam Boilers to DIN 4754

• Indirect Heating Systems to DIN 4754

OPERATING PRINCIPLEThe panel-mounting thermostats Type KM operates on the principle

of liquid expansion. A temperature change in a liquid-filled sensing

system, consisting of probe, capillary and expansion capsules,

produces a volumechange. The resulting movement of the diaphragm

acts through a mechanism to operate the microswitch.

TECHNICAL DESCRIPTIONSAFETY TEMPERATURE LIMITER STB AND SAFETY

TEMPERATURE MONITOR STW (STB) FAIL-SAFE

Failure of the measuring system, i.e. leakage of the expansion liquid,

causes the pressure under the diaphragm of the STB; STW (STB)

to drop, thus permanently opening the circuit, terminals 1-2.

Reset is no longer possible.

If the prode is cooled down to a temperature below - 10°C the

circuit, temperature 1-2 is also opened; as the temperature rises

above -10°C the STB has to be reset manually by pressing the reset

button. On the STW (STB) the circuit is re-closed automatically.

LOCK-OUT FUNCTION

On the STB, exceeding the set temperature limit causesthe circuit,

terminals 1 – 2, to be opened and locked out mechanically. After the

temperature has dropped by about 10% of span below the setpoint

the microswitch can be reset manually.

When using the STW (STB) monitor as STB limiter, the lock-out

function to DIN 440 has to be provided by a subsequent circuit.

The circuit must conform to Section 8.7 of DIN/VDE 0 118.

SETPOINT ADJUSTMENT

The setpoint can be adjusted before installation by rotating the

setting spindle with a screwdriver.

STANDARD ACCESSORYOperating Instructions B 60.2045.

TECHNICAL DATA

CASE Steel, Zinc-plated, Heat-resistant Plastic

CASE FIXING 2 Screws, M4, Spacing 28mm

SWITCH

Type KMf-70

Normally

Single-pole n.c. (break) contact opening on temperature rise - Code O

At extra charge Single-pole changeover contact Code U

Type KMf-20 Single-pole changeover contact U

SWITCHING DIFFERENTIAL IN % OF SPAN 9 +2/-3

RATING

STW (STB), STB

16 A 380 V AC

16 (2)A 250 V AC, p.f. = 1 (0.6)

0.25 A 250 V DC

STB, CODE 70/U

on n.c. (break) contact

16 A 380 V AC

16 (2)A 250 V AC, p.f. = 1 (0.6)

0.25 A 250 V DC

on n.c. (make) contact

2 A 380 V AC

2 (1)A 250 V AC, p.f. = 1 (0.6)

0.25 A 250 V DC

STB CODE 70/AU0.1 A 24 V AC/DC

contact resistance 2.5-10mΩ

Page 107: CATALOGUE - Sentien Electronicssentien-electronics.com.au/catalogues/SENTIEN_CATALOGUE.pdf · for a better protection between bezel and metal panel. TECHNICAL DATA CONTROL RANGE -50÷120°C

107

THERMOSTATS

THERMOSTAT FOR PANEL MOUNTING SERIES KMf-70; KMf-20

THERMOSTAT, M/R ADJUSTABLE

TECHNICAL DATA

ELECTRICAL CONNECTIONSNormally faston tabs A 6.3 x 0.8mm, DIN 46 244

Code X - Screw terminals up to 2.5mm² conductor cross-section

SWITCHING POINT ACCURACY(based on setpoint) in upper third of scale range +0/-5% span. Switching

point accuracy can be shifted to a different scale range to special order.

PERMITTED AMBIENT TEMPERATURE

AT THERMOSTAT HEAD AND CAPILLARY

DURING OPERATION

Maximum +80°C

Minimum -40°C for full-scale below 200°C

-20°C for full-scale 200°C to 350°C

PERMITTED STORAGE TEMPERATURE

THERMOSTAT HEAD, CAPILLARY

AND PROBE

Maximum +50°C

Minimum -50°C

PROTECTION IP00 to DIN 60 529

SCALE SPAN 250° L

OPERATING POSITION Unrestricted

WEIGHT O.3

DIN APRROVAL NO.KMf-20 STW (STB) 82294 S

KMf-20 STB 82494

DVGW APPROVAL NO. CE-0085 AR 0125

PROBE TABLE

KMf-70; KMf-20 PROBE MATERIAL COPPER (STAINLESS STEEL*)

SETPOINT RANGE °CMAX. PROBE

TEMPERATURE °C

PROBE LENGTH DIM. "L" IN mm FOR "d" PROBE DIAMETER. 6mm DIA. IS STANTARD

5 6 7 8

0 + 50 60 235 163 126 104

0 + 100 115 133 98 80 70

+ 30 + 110 130 159 115 92 79

+ 20 + 120 140 131 97 79 70

+ 60 + 130 150 175 125 99 84

+ 20 + 150 175 108 82 69 62

+ 50 + 200 230 114 83 67 59

+ 50 + 250 ** 290 90 67 56 51

+ 50 + 300 ** 345 74 57 49 45

MM INCH MM INCH MM INCH

0.8 0.031 60 2.36 125

1.5 0.06 62 2.44 126

5 0.20 67 2.64 131

6 0.24 69 2.72 133

6.3 0.25 70 2.76 159

7 0.28 74 2.91 163

8 0.31 79 3.11 175

10.5 0.41 80 3.15 235

15 0.59 82 3.23

20 0.79 83 3.27 2.5 m² 0.004 in²

28 1.10 84 3.31 1 m 3.3 ft

39 1.54 90 3.54 2 m 6.7 ft

42 1.65 92 3.62 3 m 10 ft

45 1.77 97 3.82 5 m 16.7 ft

48 1.89 98 3.86

49 1.93 99 3.90

51 2.01 104 4.09

56 2.20 108 4.25

57 2.24 114 4.49

59 2.32 115 4.53

Page 108: CATALOGUE - Sentien Electronicssentien-electronics.com.au/catalogues/SENTIEN_CATALOGUE.pdf · for a better protection between bezel and metal panel. TECHNICAL DATA CONTROL RANGE -50÷120°C

108

THERMOSTATS

DTP-0071-4

Page 109: CATALOGUE - Sentien Electronicssentien-electronics.com.au/catalogues/SENTIEN_CATALOGUE.pdf · for a better protection between bezel and metal panel. TECHNICAL DATA CONTROL RANGE -50÷120°C

109

THERMOSTATS

OPERATING TEMPERATURE CHARACTERISTICS

C

PCOLD NORMAL WARM - - -

ON (5.0) (5.0) 5.0 ± 1.3 - - -

OFF (-10.0) (-6.0) - 2.0 ± 1.3 - - -

OFF - - - - - - - - - - - -

1. Formal Operating Temperature Characteristics are based on second operating.

2. ( )... Reference Value.

3. Capillary Tube should be so installed that minimum 150mm, tube end can sense the controlled temperature.

ELECTRICAL RATING

RATED VOLTAGE (V)

(A) RATED AMPS

POWER FACTOR AC

COSø 125V 250V

NON-INDUCTIVE CURRENT C

|

L

1 1~8 0.5~4

INDUCTIVE CURRENTF.L.A 0.75 1~6 0.5~3

F.L.A 0.45 1~24 0.5~12

NON-INDUCTIVE CURRENT C

|

H

1 - - - - - -

INDUCTIVE CURRENTF.L.A 0.75 - - - - - -

F.L.A 0.45 - - - - - -

TYPE

TYPE OF CONTACT (S.P.S.T.) ARROW MARK INDICATES TEMP. RISE

CONTACT RESISTANCE Less than 50mΩ

INSULATION RESISTANCE More than 100MΩ at DC 500V Megger

DIELECTRIC STRENGTH Withstand AC 1500V for one minute.

TEMPERATURE CONDITION

IN ACTUAL USE

TS > TB Ts : Ambient Temperature at Switch Body

TB : Ambient Temperature at Sensing Bulb

CHARGE G – Charge

FOLLOW UP CHARACTERISTICS

OF SENSING BLUB

Controlled Fluid : Liquid

Temperature Change Rate : More than 1°C / 1 min

MAX. ALLOWABLE TEMPERATURESwitch Body : 70°C

Sensing Bulb : 80°C

MOUNTING OF SENSING BULB In any position

CONTACT LIFE 200,000 Cycles

NOTE 1. Cam-Shaft rotating torque cold~warm = 0.2~3.5 Kgf - cm

DTP-0071-4

Page 110: CATALOGUE - Sentien Electronicssentien-electronics.com.au/catalogues/SENTIEN_CATALOGUE.pdf · for a better protection between bezel and metal panel. TECHNICAL DATA CONTROL RANGE -50÷120°C

110

THERMOSTATS

THERMOSTATS REFRIGERATOR

ATB-X1G3, REFRIGERATORS

Page 111: CATALOGUE - Sentien Electronicssentien-electronics.com.au/catalogues/SENTIEN_CATALOGUE.pdf · for a better protection between bezel and metal panel. TECHNICAL DATA CONTROL RANGE -50÷120°C

111

THERMOSTATS

THERMOSTATS REFRIGERATOR

OPERATING TEMPERATURE CHARACTERISTICS

C

PCOLD NORMAL WARM - - -

ON (-10) - 2 ± 1.5 (8) - - -

OFF (-20) - 10.5 ± 1.5 (1.5) - - -

OFF - - - - - - - - - - - -

1. Formal Operating Temperature Characteristics are based on second operating.

2. ( )... Reference Value.

3. Capillary Tube should be so installed that minimum 150mm, tube end can sense the controlled temperature.

ELECTRICAL RATING

RATED VOLTAGE (V)

(A) RATED AMPS

POWER FACTOR AC

COSø 125V 250V

NON-INDUCTIVE CURRENT

INDUCTIVE CURRENTF.L.A 0.75 1~6 0.5~3

F.L.A 0.45 1~24 0.5~12

TYPE

TYPE OF CONTACT (S.P.S.T.) ARROW MARK INDICATES TEMP. RISE

CONTACT RESISTANCE Less than 50mΩ

INSULATION RESISTANCE More than 100MΩ at DC 500V Megger.

DIELECTRIC STRENGTH Withstand AC 1500V for one minute.

TEMPERATURE CONDITION IN

ACTUAL USE.

TS > TB Ts : Ambient Temperature at Switch Body

TB : Ambient Temperature at Sensing Bulb

CHARGE G – Charge

FOLLOW UP CHARACTERISTICS OF

SENSING BLUB

Controlled Fluid : Liquid

Temperature Change Rate : More than 1°C / 1 min

MAX. ALLOWABLE TEMPERATURESwitch Body : 70°C

Sensing Bulb : 80°C

MOUNTING OF SENSING BULB In any position

CONTACT LIFE 200,000 Cycles

CAM ROTATING TORQUE 1. Cam-Shaft rotating torque cold~warm = 0.2~3.5 Kgf - cm warm~off = 0.2~4.5 Kgf - cm

Page 112: CATALOGUE - Sentien Electronicssentien-electronics.com.au/catalogues/SENTIEN_CATALOGUE.pdf · for a better protection between bezel and metal panel. TECHNICAL DATA CONTROL RANGE -50÷120°C

112

2-WIRE IN-HEAD TEMPERATURE TRANSMITTER

TEMPERATURE TRANSMITTERS

2-WIRE IN-HEAD TEMPERATURE TRANSMITTER

2-WIRE IN-HEAD TEMPERATURE TRANSMITTER

The 2-Wire In-Head Temperature Transmitter is based on Microprocessor with flexibility for accepting

the signal mV, Pt100 and variety of Thermocouples. It delivers a scalable linear 4~20mA output current

proportional to the sensor temperature. Available option for a user-friendly configuration software is

provdided for parameter setup including sensor type, temperature range, filter ... etc.

SPECIFICATIONS

SENSOR INPUT TYPE – DESCRIPTION ACCURACY (MAX. RANGE)

THERMOCOUPLEType J / K / R / S / T / N / E According to IEC60584

(ITS-90). Impedance : 1MΩ< 0.3%

Pt1002 or 3-Wire connection (Connect terminal 2 & 3

for 2-Wire Sensor), Excitation 180μA =0.00385

according to IEC 60751 (ITS-90)

0.2%

VOLTAGE 0 ~ 50mVdc, Impedance: 1MΩ 0.2%

RESPONSE TIME < 100ms

OUTPUT 2-Wire 4~20mA, linear with respect to the measured

temperature

RESOLUTION 0.004mA (12 bits)

POWER SUPPLY 12~35 VDC across the transmitter

MAX. LOAD (RL) RL (max) = (VDC-12) / 0.02 [Ω]

OPERATION TEMPERATURE & HUMIDITY -40 to 85°C , 0 to 90% RH

ELECTROMAGNETIC COMPATIBILITY EN 50081-2, EN 50082-2

HOUSING ABS Plastic (Dimension: Dia. 44m x Height 25mm)

NOTE No isolation between the sensor and the 4~20mA loop. Internal protection against polarity inversion, cold junction

compensation for the thermocouple.

SPECIFICATION

ACCURACY ±0.1% FS (At 23ºC)

INPUT RANGE -100 ~ 600ºC

OUTPUT 4 – 20mA, Linear with respect to the

measured temperature

POWER SUPPLY 10 ~ 30VDC

MAX. LOAD (RL) RL (max) = (VDC-10) X 50 [Ω]

LIMITED OUTPUT CURRENT Under 25mA

TEMP. COEFFICIENT ±0.02% / ºC

OPERATION TEMPERATURE & HUMIDITY -5 to 70ºC, 0 to 90% RH

SPAN ADJUSTMENT

1 30 ~ 60ºC

2 80 ~ 160ºC

3 150 ~ 300ºC

4 200 ~ 400ºC

5 300 ~ 600ºC

S Specified

WIRING DIAGRAM

WITH LED INDICATION AND DC

POWER POLARITY PROTECTION

ZERO ADJUSTMENT Standard is 0ºC

Page 113: CATALOGUE - Sentien Electronicssentien-electronics.com.au/catalogues/SENTIEN_CATALOGUE.pdf · for a better protection between bezel and metal panel. TECHNICAL DATA CONTROL RANGE -50÷120°C

113

VALVES

VALVES

2- AND 3- WAY MOTORIZED BALL VALVE

3- WAY MOTORIZED GLOBE VALVE

AIR FLOW SWITCH

• To control the flow rate of water, with equal percentage feature, in ventilation,

air-conditioning and heating systems.

• Ball valves are operated by a rotary servo control with two way rotation.

• To control the flow rate of water, with equal

percentage feature, in ventilation, air-conditioning

and heating systems.

• Globe valves are operated by a linear servo control.

• Suitable for signalling, controlling and regulating

the air flow in air conditioning systems; to

control fans, compressors, etc.

• Case in shock-proof plastic with

self-retaining screws

• AISI 301 stainless steel flexible blade

(50 x 165mm)

• Electric connections on Faston 6.3 (provided)

• Calibration screw for adjusting the cut-in point

• PVC flange, 5mm thick

• Compliance with standards CEI EN 60730-1

• SPDT single-pole switching microswitch

ELECTRIC SPECIFICATIONSRATED INSULATION VOLTAGE Ui 380V-

CONTINUOUS DUTY RATED CURRENT Ith 10A

RATED OPERATING CURRENT IE 220V- 250V-

RESISTIVE LOAD AC-12 10A

INDUCTIVE LOAD AC-15 3A

DIRECT CURRENT DC-13 0,2A

2 WAY

DN

mm

FEMALE

THREADED

FITTING

KV

m³/h

PRESSURE

RATED

BAR

DIFF.

BAR

Z20L 15 1/2" 4 16 3,5

Z20M 20 3/4" 6,3 16 3,5

Z20A 25 1" 10 16 3,5

Z20B 32 1" 1/4 16 16 3,5

Z20C 40 1" 1/2 25 16 3,5

Z20D 50 2" 40 16 3,5

2 WAY

DN

mm

FEMALE

THREADED

FITTING

KV

m³/h

PRESSURE

RATED

BAR

DIFF.

BAR

ZL30A 15 G1" 4 16 4

ZL30B 20 G1" 1/4 6.3 16 4

ZL30C 25 G1" 1/2 10 13 4

ZL30D 32 G2" 16 8 4

ZL30E 40 G2" 1/4 25 4,9 4

ZL30F 50 G2" 1/2 40 3 3

3 WAY

DN

mm

FEMALE

THREADED

FITTING

KV

m³/h

PRESSURE

RATED

BAR

DIFF.

BAR

Z30L 15 1/2" 4 16 3,5

Z30M 20 3/4" 6,3 16 3,5

Z30A 25 1" 10 16 3,5

Z30B 32 1" 1/4 16 16 3,5

Z30C 40 1" 1/2 25 16 3,5

Z30D 50 2" 40 16 3,5

3 WAY WITH FLANGE

DN

mm

KV

m³/h

PRESSURE

RATED

BAR

DIFF.

BAR

ZL31A 25 10 13 4

ZL31B 32 16 8 4

ZL31C 40 25 4,9 4

ZL31D 50 40 3 3

ZL31E 65 63 4 4

ZL31F 80 100 2,7 2,7

ZL31G 100 145 1,6 1,6

ZL31H 125 220 0,9 0,9

ZL31I 150 320 0,5 0,5

DETAILS

DUCT

SURFACE cm²

MAXIMUM IN-

CREASING FLOW

SPEED m/sec

MAXIMUM DE-

CREASING FLOW

SPEED m/sec

OPERATING

TEMPERATURE

MAXIMUM

AMBIENT

TEMPERATURE

PROTECTION

LEVEL

FF71A

160 1,4 0,6

-20 to 70 50°C IP54320 2,2 1,2

640 3 1,6

1280 3 1,7

Z20

Z30

ZL30

ZL31

Page 114: CATALOGUE - Sentien Electronicssentien-electronics.com.au/catalogues/SENTIEN_CATALOGUE.pdf · for a better protection between bezel and metal panel. TECHNICAL DATA CONTROL RANGE -50÷120°C

114

SOLENOID VALVES

VALVES

DIRECT ACTING SOLENOID VALVE BODIES

SERVO-ASSISTED DIAPHRAGM NORMALLY CLOSED VALVE BODIES

• Solenoid valves suitable for water, air, fuel-oil, inert gases and other fluids non-corrosive for copper alloys, with viscosity up to 2° Engler2-way normally closed.

• Direct action• With the coil energized, the valve opens

immediately to allow fluid to pass.• Closing time 10 msec.• Stamped brass valve body.• Stainless steel internal parts (17%CR).• VITON seals (fluroelastomer).• Test Pressure PN (DIN 2401):25 bar• With coil in dc the pressure indicated

is reduced by 60%• Coils suppled separated from the body.

• Solenoid valves suitable for large flow capacity, suitable for water, air, fuel-oil, inert gases and other fluids non-corrosive for copper alloys, with viscosity up to 2° Engler

• 2-way normally closed• Indirect operation with servo-diaphragm blocked.• Minimum operating pressure between upstream

and downstream must be 0.1 bar• Stamped brass valve body• Stainless steel internal parts (17% CR)• NBR seals (BUNAN)

• With coil in dc the maximum pressure indicated in the table is reduced to 60%

• Coils supplied separated from the body• Closing time : 10 msec• Press-forged brass body• Internal parts in stainless steel (17% CR).• Gaskets in NBR (buna N)• With DC coil indicated pressure values must

be reduced to 60%.• Gasket in Viton available on request only

for sizes up to G1"

SPECIFICATIONS

ORIFICEDIAMETER

mm

FEMALE UNION

KVm³/h

MAXIMUM DIFFERENTIAL PRESSURE

TEST PRESSURE(DIN 2401)

PN BAR

OPERATING TEMPERATURE

Vn BAR 0.85Vn BAR

M20B3 3 G 1/4 0,27 16 10 25 -10 to 140

M20C5 5 G 3/8 0,612 6 2 25 -10 to 140

M20D5 5 G 1/2 0,612 6 2 25 -10 to 140

M20E7 7 G 3/4 1 2,5 1,8 25 -10 to 140

Kv = flow rate in m³/h of water with difference in downstream and upstream pressures of 1 bar (1 bar = 100 kPa)

For IM21 bi-frequency coils used at 60 Hz, the values indicated are reduced by an average of 12%.

SOLENOID VALVES with test certificates isssued by the Study and Experience Centre of the MINISTRY OF THE

INTERIOR Fire-Prevention Service Rome Capannelle.

SPECIFICATIONS

ORIFICEDIAMETER

mm

FEMALE UNION

KVm³/h

CLOSING TIME

DP DI OF 1 BAR

MINIMUM

OPERATING

PRESSURE

BAR

MAXIMUM

DIFFERENTIAL

PRESSURE

TEST PRESSURE (DIN2401) PN-BAR

M23C13 13 G 3/8 3 1 0,1 20 25

M23D13 13 G 1/2 3 1 0,1 20 25

M23E20 20 G 3/4 8,4 1,5 0,1 20 25

M23F25 25 G 1 9,6 1,5 0,1 20 25

M23G35 35 G 1 1/4 25,2 2,5 0,1 10 16

M23H40 40 G 1 1/2 30 3 0,1 10 16

M23I50 50 G 2 37,2 3,5 0,1 10 16

24V

CONTROL

COIL

110/115V230V CONNECTOR

ORIFICE mm

UNION KVm³/h

WORKINGPRESSURE

BAR

M20C5 IM21F IM21H IM21M 1578501 5 G 3/8 0,612 0 to 2

M20D5 IM21F IM21H IM21M 1578501 5 G 1/2 0,612 0 to 2

M20E7 IM21F IM21H IM21M 1578501 7 G 3/4 1 0 to 2

M20C51 IM22F – – 1578501 5 G 3/8 0,612 0 to 2

M20D51 IM22F – – 1578501 5 G 1/2 0,612 0 to 2

M20E71 IM22F – – 1578501 7 G 3/4 1 0 to 2

Page 115: CATALOGUE - Sentien Electronicssentien-electronics.com.au/catalogues/SENTIEN_CATALOGUE.pdf · for a better protection between bezel and metal panel. TECHNICAL DATA CONTROL RANGE -50÷120°C

115

REFRIGERATION SOLENOID VALVES

SERIES 68 AD

FUILD CONTROL COMPONENTS

SPECIFICATIONS

ATTACCHI PIPES

IN -> OUT

Ø

MM

CODE KV

M³/H

M.O.P.D.

BAR

DIMENSIONS

MM

WEIGHT

KG

AC DC A B C D

ODF 6MM 2,5 6806 0,170 25 17 111 67 47 50 0,220

ODF 1/4" 2,5 6807 0,170 25 17 111 67 47 50 0,220

ODF 10 MM 3,0 6810 0,230 25 17 116 78 60 59 0,360

ODF 3/8" 3,0 6811 0,230 25 17 116 78 60 59 0,360

1/4" SAE – UNF

7/16"2,5 6812 0,170 25 17 65 67 47 50 0,220

3/8" SAE – UNF

5/8"3,0 6813 0,230 25 17 71 78 60 59 0,395

ODF 6MM 2,5 6825 0,170 25 17 105 136 47 49 0,210

ELECTRICAL INFORMATION

POWER

6806-07-12-25 6810-11-13

HOLDING IN RUSH HOLDING IN RUSH

V~ 12 24 49 110 230 400 50 60 Hz 17, 5VA 28VA 23VA 33VA

V= 12 24 48 110 16W 21W

FOR CONSTRUCTION DETAILS OF THE COILS SEE CHAPTER " PROJECT INFORMATION"

MAX. TEMPERATURE

FLUIDS AMBIENT

PTFE NEOPRENE- 30 + 80°C

-45 + 125°C -35 + 100°C

PRESSURE LOSS DIAGRAMDetailed information on the flow rate

capacity for the various "refrigeration

fluids" are available under chapter

"Project Information".

DIAGRAM

1 Dado Lock Nut

2 Rondella Washer

3 Bobina Coil

4 Nucleo Fisso Tube Top

5 Molla Spring

6 Nucleo Mobile Plunger

7 Piattello Support

8 Pastiglia Seat

9 Rondella Washer

10 Corpo Valve Body Base

RICAMBI SPARE PARTS

A Bombina Coil

6806 6810 6812 6813 6825

Page 116: CATALOGUE - Sentien Electronicssentien-electronics.com.au/catalogues/SENTIEN_CATALOGUE.pdf · for a better protection between bezel and metal panel. TECHNICAL DATA CONTROL RANGE -50÷120°C

116

REFRIGERATION SOLENOID VALVES

SERIES 68 AD

SOLENOID VALVE DIRECT ACTING 2/2 WAY N.C.

GENERAL FEATURES

MINIMUM WORKING PRESSURE 0 BAR

PARTS IN CONTACT WITH THE FLUID

SEALING PTFE

BODY Brass

INTERNAL PARTS Stainless Steel

FLUIDSAll type of Refrigerant fluids except

Ammonia (NH³)

ONE WAY DIRECTION VALVE

NON-SEVICEABLE VALVE

VALVE SUPPLIED WITH

- Three pole plug connector UNI ISO 4400

(DIN 43650A) - IP 65

- Screw and mounting bracket.

(Except for Series 6825)

MOUNTING POSITION

Any to obtain the best performances

the valves has to be installed with the

coil vertical; the position with the coil

downwards is not recommended.

AMBIENT TEMPERATURE

- 30°C + 80°C, in D.C. for temperatures

higher than 40°C, the performances

(M.O.P.D.) could decrease.

SPECIAL EXECUTIONS Sealing in Neoprene (6806-6812)

ACCESSORIESNut and gasket to aid against humidity for

the coil SAE nut for copper tube connection.

Page 117: CATALOGUE - Sentien Electronicssentien-electronics.com.au/catalogues/SENTIEN_CATALOGUE.pdf · for a better protection between bezel and metal panel. TECHNICAL DATA CONTROL RANGE -50÷120°C

117

FUILD CONTROL COMPONENTS

SPECIFICATIONS

ATTACCHI PIPES

IN -> OUT

Ø

MM

CODE KV

M³/H

M.O.P.D.

BAR

DIMENSIONS

MM

WEIGHT

KG

AC DC A B C D

3/8" SAE – UNF

5/8"8 6853 1,300 28 17 84 91.5 60 73.5 0.520

1/2" SAE – UNF

3/4"10 6854 1,600 28 17 84 91.5 60 73.5 0.520

ODF 10 mm 8 6851 1,300 28 17 118 91.5 60 73.5 0.460

ODF 12 mm 10 6862 1,600 28 17 118 91.5 60 73.5 0.460

ODF 3/8" 8 6863 1,300 28 17 118 91.5 60 73.5 0.460

ODF 1/2" 10 6864 1,600 28 17 118 91.5 60 73.5 0.460

ELECTRICAL INFORMATION

POWER

6806-07-12-25

HOLDING IN RUSH

V~ 12 24 49 110 230 400 50 60 Hz 30VA 33VA

V= 12 24 48 110 20W

FOR CONSTRUCTION DETAILS OF THE COILS SEE CHAPTER " PROJECT INFORMATION"

MAX. TEMPERATURE

FLUIDS AMBIENT

PTFE- 30 + 80°C

-45 + 125°C

REFRIGERATION SOLENOID VALVES

SERIES 68 SC

1 Dado Lock Nut

2 Rondella Washer

3 Bobina Coil

4 Nucleo Fisso Tube Top

5 O-Ring O-Ring

6 Molla Spring

7 Nucleo Mobile Plunger

8 Pistiglia Seat

9 Fascia Elastica Piston Rings

10 Otturatore Shutter

11 Corpo Valve Body Base

RICAMBI SPARE PARTS

A Bombina Coil

B Cannotto Tube Guid

C Nudeo Mobile Plunger

D Otturatore Shutter

6853 6854 6861 6862

Page 118: CATALOGUE - Sentien Electronicssentien-electronics.com.au/catalogues/SENTIEN_CATALOGUE.pdf · for a better protection between bezel and metal panel. TECHNICAL DATA CONTROL RANGE -50÷120°C

118

SOLENOID VALVE DIRECT ACTING 2/2 WAY N.C.

GENERAL FEATURES

MINIMUM WORKING PRESSURE 0,1 BAR

PARTS IN CONTACT WITH THE FLUID

SEALING PTFE

BODY Brass

INTERNAL PARTS Stainless Steel

FLUIDSAll type of Refrigerant fluids except

Ammonia (NH³)

ONE WAY DIRECTION VALVE

NON-SEVICEABLE VALVE

VALVE SUPPLIED WITH

- Three pole plug connector UNI ISO 4400

(DIN 43650A) - IP 65

- Screw and mounting bracket.

(Except for Series 6825)

MOUNTING POSITION

Any to obtain the best performances

the valves has to be installed with the

coil vertical; the position with the coil

downwards is not recommended.

AMBIENT TEMPERATURE

- 30°C + 80°C, in D.C. for temperatures

higher than 40°C, the performances

(M.O.P.D.) could decrease.

SPECIAL EXECUTIONS Sealing in Neoprene (6806-6812)

ACCESSORIES

A special coil B20 (30W) is available

to increase performances (M.O.P.D.) in

D.C. SAE nut for copper tube connection.

Nut and Gasket to aid against humidity

for the coil.

REFRIGERATION SOLENOID VALVES

SERIES 68 SC

Page 119: CATALOGUE - Sentien Electronicssentien-electronics.com.au/catalogues/SENTIEN_CATALOGUE.pdf · for a better protection between bezel and metal panel. TECHNICAL DATA CONTROL RANGE -50÷120°C

119

Page 120: CATALOGUE - Sentien Electronicssentien-electronics.com.au/catalogues/SENTIEN_CATALOGUE.pdf · for a better protection between bezel and metal panel. TECHNICAL DATA CONTROL RANGE -50÷120°C

Let us put you in ControlLet us put you in Control

OFFICE52 TUNGARRA ROAD GIRRAWEEN NSW 2145 AUSTRALIA

PO BOX 337 TOONGABBIENSW 2146 AUSTRALIA

TEL (02) 9896 4512FAX (02) 9896 [email protected]