Upload
others
View
1
Download
0
Embed Size (px)
Citation preview
Let us put you in Control
CATALOGUEREFRIGERATION | HEATING | AIR-CONDITIONING
SPEED CONTROLS | SECURITY SYSTEMS
LAE | FANTINI COSMI | WEISS INSTRUMENTS | NHD | GO-LINK
2
3
Sentien Electronics Pty Ltd was established in 1993.
Sentien Electronics is a distributor for Refrigeration, Heating
and Air-Conditioning controls. The company’s focus has always
been to provide quality products at competitive prices which
meet our customers needs, with an emphasis on reliability
and customer service.
Sentien Electronics prides itself on customer service, with our
knowledgeable and dedicated staff prepared to go the extra
mile to ensure customer satisfaction. It is with this philosophy
and dedication to service which has ensured that Sentien
Electronics has continued to grow and create a trusted name
among its customers and the industry in which it serves.
Throughout the years Sentien Electronics has formed valuable
partnerships with our suppliers which is the key to our success.
Our products are sourced globally from companies which share
the same dedication and philosophy that we do.
Companies such as LAE Electronic, which have been
manufacturing for over 40 years and supply customers such
as Williams Refrigeration, Foster Refrigeration, ATLAS COPCO ,
Criosbanc Carrier and LEC Refrigeration.
We supply Panel Mount, Wall Mount, Din Rail Mounted thermostats
for Normal, Medium and Low Temperature applications. They also
supply a range of Humidity, Pressure and Rack controls, as well
as a range of software for both on-site and remote monitoring that
can be either hard wired or wirelessly networked.
Fantini Cosmi is a European leader for Temperature, Pressure,
Level & Flow Controls in the Heating sector and has been
manufacturing since 1938.
I.C.M. – A USA supplier of Timers, De-Ice Controls, Phase
failure & phase sequence controls, Digital room thermostats.
WEISS Instruments – A USA supplier which has been
manufacturing Temperature & Pressure gauges since 1899.
NHD – A Taiwanese manufacturer of Magnetic Motor Controls,
Contactors, Overloads, enclosures, Soft starters, SCR Power
controllers, with ISO9002, UL, SA, CE Approvals.
We also have access to a wide range of products such as
Differential Air Pressure switches, Axial Cross flow and External
Rotor fans, Centrifugal, forward & backward curved fans, Blower
fans, Electronic fans, power supplies, speed controls, dimmers,
manual reset thermostats, flow switches, Refrigeration, water and
oil solenoid valves. Current sensing switches, pressure transducer,
data loggers, hand-held thermometers, humidity, anemometers,
thermocouples, heating elements for Bain Maries & Hot food bars.
Indicator lamps, rocker, toggle, rotary switches, T8 LEDs in various
sizes, fixed LED strips, flexible LED strips, RGB LEDs.
Our aim is to provide a one stop shop with various products
complimenting the LAE range of digital controls. If you are
interested in a product or products not listed above, feel free
to contact us with your requirements, and we will contact our
sources around the world in an endeavour to provide you with
the optimal solution for your needs.
We look forward to hearing from you in the future.
COMPANY OVERVIEW
SENTIEN ELECTRONICS
4
5
PAGE INDEX
PRODUCT INDEX
CONTENT PAGES
FANS 24 – 28
VOLTAGE STABILISERS 53
THERMOCOUPLE & RTD PROBES 93
CONTACTORS 16 – 22
CIRCUIT BREAKERS 13 – 15
INDICATOR LIGHTS 44 – 49
TEMPERATURE CONTROLLERS 86 – 88
REFRIGERATION SOLENOID VALVES 115 – 118
DATA LOGGERS 23
POWER SUPPLIES 50 – 52
TERMINALS 89 – 92
METERS 34 – 41
SWITCHES 64 – 85
TEMPERATURE TRANSMITTERS 112
ACTUATORS 12
LAE ELECTRONICS 06 – 11
PHASE MONITORS 42 – 43
VALVES 113 – 114
HEATING ELEMENTS 33
RELAYS 55 – 63
THERMOSTATS 101 – 111
FAN SPEED CONTROLS 29 – 32
SCR POWER CONTROLLERS 54
TIMERS 94 – 100
6
CONTROLLERS
LAE ELECTRONIC
ATI-5 UNIVERSAL DEFROST CONTROLLER – FOR HIGH TEMPERATURE
AT2-5 UNIVERSAL DEFROST CONTROLLER – FOR HIGH AND LOW TEMPERATURE
ATI-5
AT2-5
SPECIFICATIONS
FUNCTIONS AS1E-G BS2E-BG BS6E-AL
INPUTS
THERMOSTAT √ √ √
EVAPORATOR √ √
DOOR SWITCH √ √
OUTPUTS
THERMOSTAT 16(4)A √ √
THERMOSTAT 16(8)A √
AUXILIARY 7(2)A √ √
POWER SUPPLY 230VAC √ √ √
SERIAL PORTTTL √
RS485 √
KEYPADGENERIC √ √
WITH LIGHT BUTTON √
SPECIFICATIONS
FUNCTIONS BS4E-G BS4E-BG BS4E-AL
INPUTS
THERMOSTAT √ √ √
EVAPORATOR √ √ √
DOOR SWITCH √ √ √
OUTPUTS
THERMOSTAT √ √ √
EVAPORATOR FANS √ √ √
AUXILIARY √ √ √
POWER SUPPLY 230VAC √ √ √
SERIAL PORT SERIAL PORT TTL √ √
KEYPADGENERIC √ √
WITH LIGHT BUTTON √
APPLICATIONFreestanding upright cabinets and counters, cold stores, plug-in display cases,
control panels, heated cabinets.
Models with removable screw terminal blocks are available. In this case, the letter
“S” of code changes in “Q”, ex. AT1-5BQ2E-BG. All models come with an alarm buzzer.
Versions with 110V power supply are available. On request, the AT1-5 is also available
with gasket for a better protection between bezel and metal panel.
APPLICATIONHigh or Low Temperature upright cabinets and counters, cold stores, plug-in display cases,
control panels, heated cabinets.
Models with removable screw terminal blocks are available. In this case, the letter “S” of
code changes in “Q”, ex. AT2-5BQ4E-AL. All models come with an alarm buzzer. Versions
with 110V power supply are available. On request, the AT2-5 is also available with gasket
for a better protection between bezel and metal panel.
TECHNICAL DATACONTROL RANGE -50÷120°C , -55÷240°F RESOLUTION 0.1 / 1 °C; °F
ACCURACY NTC10K: <±0.3°C (-40.0÷70.0°C) PTC1000: <±0.5°C (-50÷120°C)
POWER SUPPLY 230V~ ±10% 50÷60Hz 3W FRONT PROTECTION IP55
PANEL CUT-OUT 71x 29 mm
SENSOR TYPE selectable NTC10K standard mod.
SN4K20P1/P2 or PTC1000 standard mod. ST1K20P1/P2
TECHNICAL DATACONTROL RANGE -50÷120°C , -55÷240°F RESOLUTION 0.1 / 1 °C; °F
ACCURACY NTC10K: <±0.3°C (-40.0÷70.0°C) PTC1000: <±0.5°C (-50÷120°C)
POWER SUPPLY 230V~ ±10% 50÷60Hz 3W FRONT PROTECTION IP55
PANEL CUT-OUT 71x 29 mm
SENSOR TYPE selectable NTC10K standard mod. SN4K20P1/P2
or PTC1000 standard mod. ST1K20P1/P2
• Selectable Refrigerating or Heating control • Runs on mains power supply
• Direct compressor control through high power 16(4)A, 16(5)A or 16(8)A relay
• Selectable NTC10K or PTC probe input • Integrated defrost functions
• Auxiliary output configurable in four different operation modes • On/Off button
• Absolute or relative temperature alarms • Door open alarm
• Automatic condenser maintenance warning • Connection to LAE supervisory systems
• Optional light control button • Quick programming through ZOT-AT1 key
• Selectable Refrigerating or Heating control • Runs on mains power supply
• Direct compressor control through high power 16(5)A • Excellent evaporator fan control
• Selectable NTC10K or PTC input • Integrated defrost functions
• Auxiliary output configurable in six different operation modes • On/Off button
• Absolute or relative temperature alarms • Door open alarm
• Automatic condenser maintenance warning • Connection to LAE supervisory systems
• Optional light control button • Quick programming through ZOT-AT2 key
• Electrical, off cycle or hot gas defrost
16(8)A
T1ComT2
doorswitch
7(2)AAUX
door
230Vac
TTL
16(5)A
TTL
T1ComT2
DoorSwitch
7(2)A 7(2)AAUX
230Vac
7
LTR-5 SINGLE OUTPUT ON/OFF OR PID THERMOSTAT OR HUMIDISTAT
LT12 WIDE RANGE THERMOMETER OR HYGROMETER
CONTROLLERS
LAE ELECTRONIC
LT12
LTR-5
SPECIFICATIONS
FUNCTIONS CT D/I/E CP D/I/E CJ D/I/E CK D/I/E CA D/I/E
INPUT TYPE PTC* Pt100 TC "J" TC "K" 0 ÷ 1V
RANGE -50 ÷ 150ºC -100 ÷ 600ºC -50 ÷ 700ºC -50 ÷ 900ºC 0 ÷ 100% rH
ACCURACY S1**=±0.2°C; S2**=±1°C ±3°C ±0.1%
RESOLUTION S1**=0.1°C; S2**=1°C 1ºC 0.1%
SUPPLY ..D=12Vac/dc; 2W /..I=24Vac/dc; 3W /..E=230Vac ±10%; 50/60 Hz; 2W
PROTECTION IP54
PANEL CUT-OUT 71 x 29 mm
SPECIFICATIONS
FUNCTIONS LTR-5T LTR-5C LTR-5A
INPUT TYPE PTC NTC10K 0÷1V
RANGE-50÷150°C
-60÷300°F
-40÷125°C
-40÷260°F0÷99.9% r.H.
ACCURACY ±0.3°C(a); ±1.0°C(c) ±0.3°C(b); ±1°C(c) ±0.7% r.H.
RESOLUTION 0.1/1°C; °F 0.1/1 % r.H.
FRONT PROTECTION IP55
PANEL CUT-OUT 71 x 29 mm
LTR-5 T E R S -B
1 2 3 4 5
POS FUNCTION DESCRIPTION
1 INPUT T*= PTC; C**= NTC10K; A= 0÷1V
2 CONNECTORS S= screw terminals; Q= male + female terminals
3 OUTPUT TYPE R = relay; F = SSR drive
4 SUPPLY D =12Vac/dc; E =230Vac; U =115Vac, 2W
5 SERIAL COMM. - = no serial port; -A = TTL; -B = RS485
APPLICATIONTEMPERATURE accurate measurements in cold stores, refrigerating cabinets and tables,
greenhouses, seasoning cells, high temperature ovens or furnaces.
HUMIDITY accurate measurements in greenhouses, seasoning cells, air-conditioned rooms.
* Standard PTC probe is ST1K20P1
**Scale: S1 = -19.9÷99.9°C; S2 = remaining
Models with °F scale are also available.
APPLICATIONTEMPERATURE Control of small cold stores, refrigerated cabinets and tables,
heating systems, heated cupboards, bainsmarie,ovens, laboratory equipment.
HUMIDITY Control of greenhouses, seasoning cells, cold rooms, air-conditioned rooms.
HOW TO ORDER EXAMPLES
LTR-5CSRE-A (NTC10K input, 1 relay, screw terminals, 230Vac supply, TTL port)
LTR-5ASRU (0÷1V input, 1 relay, screw terminals, 115Vac supply, no serial port)
On request, the LTR-5 is also available with gasket for a better protection
between bezel and pane.
• Panel display unit with range between –100 and +900°
• It’s available in the version with °C or °F
• 0.1° or 1° resolution Input for PTC / Pt100 / TC / 0 ÷ 1V
• Runs on mains power supply.
• Runs on mains power supply
• PID with autotuning or ON/OFF control
• Output on relay (16A) or SSR piloting
• Input for PTC, NTC10K or 0÷1V 0.1 / 1°C or 1°F resolution
• Refrigerating (dehumidifying) or heating (humidifying) control mode selection
• Stand-by button on the front
• Load start limitation and safety function in the event of breakage of the sensor
• Quick setup through ZOT-LTR device
• Connection to LAE supervisory systems TAB.
OUT116(4)A
RS485
230V~
8
LAE ELECTRONIC
CONTROLLERS
AC1-5 TWO CHANNEL UNIVERSAL CONTROLLER, ON/OFF OR PID
AC1-2W UNIVERSAL DEFROST CONTROLLER – FOR HIGH AND LOW TEMPERATURE
AC1-5
AC1-2W
APPLICATIONTemperature: Control of small cold stores, refrigerated cabinets and tables,
heating systems, heated cupboards, bains-marie, ovens, laboratory equipment.
Humidity: Control of greenhouses, seasoning cells, cold rooms, air-conditioned rooms.
HOW TO ORDER
AC1-5TS2RW-A (PTC/NTC10K input, screw terminals, 2 relays,
115÷230Vac supply voltage, TTL port)
AC1-5AS2MD-B (0÷1V input, screw terminals, output 1 on SSR drive,
output 2 on relay, 12Vac/dc supply voltage,RS485 port)
* = in the version with 12Vac/dc power supply, the maximum voltage on the outputs
is 50Vac/dc, in order to ensure safety insulations.
(a) -50÷150°C; (b) remaining range.
APPLICATIONTEMPERATURE control of small cold stores, heating systems, bains-marie, ovens,
laboratory equipment.
HOW TO ORDER
AC1-2WTQ2RE-B (PTC/NTC10K input, detachable screw terminals, 2 relays,
230Vac supply voltage, RS485 port)
AC1-2WAQ2RD-A (0÷1V input, detachable screw terminals, 2 relays,
12Vac/dc supply voltage, TTL port)
• Selectable Refrigerating or Heating control • Runs on mains power supply
• Direct compressor control through high power 16(4)A, 16(5)A or 16(8)A relay
• Selectable NTC10K or PTC probe input • Integrated defrost functions
• Auxiliary output configurable in four different operation modes • On/Off button
• Absolute or relative temperature alarms • Door open alarm
• Automatic condenser maintenance warning • Connection to LAE supervisory systems
• Optional light control button • Quick programming through ZOT-AT1 key
• Wall-mount controller • Runs on mains power supply
• PID with autotuning or ON/OFF control • Outputs on relay or for SSR-piloting
• Input for 0÷1V, PTC/NTC10K • 0.1 / 1°C or 1°F resolution
• Selectable Refrigerating/Heating (Dehumidifying/Humidifying) control
• Absolute or relative temperature alarms ON/OFF button on front
• Load start limitation and safety operation in case of probe failure
• Quick programming through ZOT-AC1 key
• Connection to LAE TAB supervisory systems
12(4)A
RS485
7(2)A
115...230Vac
OUT1 OUT2
data I/O
230V ~
OUT2
RS485
OUT18(3)A8(3)A
AC1-5 T S 1 R W -B
1 2 3 4 5 6
POS FUNCTION DESCRIPTION
1 INPUT A = 0÷1V; I = 0/4÷20mA ; J = TC ‘J’ / ‘K ’; P = Pt100; T = PTC/ NTC10K
2 CONNECTIONS S = built-in screw terminals
3 OUTPUT NO. 1 = one; 2 = two
4 OUTPUT TYPE R = relay; M = O ut1 on SSR, Out2 o n relay
5 SUPPLY D* = 12Vac/dc; W = 115…230V ac 50/60Hz; 3 W
6 SERIAL COMM. Nil = no; -A = TTL; -B = RS485
AC1-2W T Q 1 R E -B
1 2 3 4 5 6
POS FUNCTION DESCRIPTION
1 INPUT A = 0÷1V; T = PT C/ NTC10K
2 CONNECTIONS Q = detachable screw terminals
3 OUTPUT NO. 1 = one; 2 = two
4 OUTPUT TYPE R = relay; F = SSR d rives
5 SUPPLY D = 12Vac/dc; E = 230Vac 50/60 Hz; U= 115Vac 50/60Hz 3 W
6 SERIAL COMM. Nil = no; -A = TTL; -B = RS485
SPECIFICATIONS
FUNCTIONS AC1-5T AC1-5P AC1-5J AC1-5A AC1-5I
INPUT TYPE PTC NTC10K Pt100 TC "J" TC "K" 0 ÷ 1V 0/4÷20mA
RANGE-50÷150ºC
-60÷300ºC
-40÷125ºC
-40÷260ºC-100÷850ºC
-150÷999ºC
-50÷750ºC
-60÷999ºC
-50÷999ºC
-60÷999ºCConfigurable in setup
ACCURACY ±0.3°C ±0.3°C±0.3°C(a);
±1°C(b)±3°C ±3mV ±0.2mA
RESOLUTION 0.1 / 1 °C / 1 °F 1 °C / °F 0.1/1
SPECIFICATIONS
FUNCTIONS AC1-5T AC1-5J
INPUT TYPE PTC NTC10K 0÷1V
-50÷150°C
-60÷300°F
-40÷125°C
-40÷260°FConfigurable in setup
ACCURACY ±0.3°C ±0.3°C ±3mV
RESOLUTION 0.1 / 1 °C / 1 °F 0.1/1
9
LAE ELECTRONIC
AD-32 UNIVERSAL POWERFUL DEFROST CONTROLLER
AD2-28 VERSATILE SPLIT DEFROST CONTROLLER
CONTROLLERS
AD-32
AD2-28
SPECIFICATIONS
FUNCTIONS Q13W-AG S24W-AG S35W-BG
TEMPERATURE
INPUTS
THERMOSTAT √ √ √
EVAPORATOR √ √ √
AUXILIARY √ √
DIGITAL INPUTS VOLTAGE FREE CONTACT √ √ √
DIGITAL INPUTS
VOLTAGE FREE CONTACT √
12 ÷ 24VAC VOLTAGE √
DEFROST SYNCHRONISATION √
OUTPUTS
THERMOSTAT 15(5)A √ √ √
EVAPORATOR FANS √ √ √
DEFROST √ √ √
AUXILIARY 1 √ √
AUXILIARY 2 √
CONNECTIONSSCREW TERMINALS √ √
M/F TERMINALS + FASTONS √
POWER SUPPLY 230VAC √ √ √
SERIAL PORTSERIAL PORT TTL √ √
SERIAL PORT RS485 √
APPLICATIONPlug-in cabinets, supermarket display cases, cold stores, upright fridges and freezers, refrigerated tables.
All models come with an alarm buzzer. On request, the AD-32 is also available with 7…30Vdc power supply.
APPLICATIONUpright refrigerators, plug-in and supermarket display cases, cold stores, control panels.
All models come with an alarm buzzer. Versions with power supply 12Vac are also available.
TECHNICAL DATACONTROL RANGE -50÷120°C , -55÷240°F RESOLUTION 0.1 / 1 °C; °F
ACCURACY NTC10K: <±0.3°C (-40.0÷70.0°C) PTC1000: <±0.5°C (-50÷120°C)
POWER SUPPLY 115÷230V~ ±10% 50÷60Hz 3W FRONT PROTECTION IP55
PANEL CUT-OUT 163 x 31.5 mm
SENSOR TYPE selectable NTC10K standard mod. SN4K20P1/P2/P3
or PTC1000 standard mod. ST1K20P1/P2/P3
TECHNICAL DATACONTROL RANGE -50÷120°C , -55÷240°F RESOLUTION 0.1 / 1 °C; °F
ACCURACY NTC10K: <±0.3°C (-40.0÷70.0°C) PTC1000: <±0.5°C (-50÷120°C)
POWER SUPPLY 230VAC ± 10% 50 ÷ 60Hz 3W FRONT PROTECTION IP55
PANEL CUT-OUT 71x 29 mm DIMENSIONS 77x35x20 mm (WxHxD)
SENSOR TYPE selectable NTC10K standard mod. SN4K20P1/P2
or PTC1000 standard mod. ST1K20P1/P2
• Selectable Refrigerating or Heating control • Selectable NTC10K or PTC input
• FLEXICOLD function for energy saving or alternative setpoint
• Timed or optimised defrost control
• Synchronized defrost start and termination with master-slave connection
• Optional control of a second compressor or evaporator
• Excellent evaporator fan control • Connection to LAE supervisory systems
• Absolute or relative temperature alarms and door open alarm
• Temperature and pressure monitoring and condensing unit maintenance
• Light and standby control (On/Off) • Quick programming through ZOT-AD key
• Cyclic defrosts • Synchronized defrost start and termination with master-slave connection
• Selectable NTC10K or PTC input • Light and standby control (On/Off)
• FLEXICOLD function for energy saving or alternative setpoint
• Optional control of a second compressor or evaporator
• Excellent evaporator fan control • Quick programming through ZOT-AD2
• Absolute or relative temperature alarms, door open alarm,
condenser high temperature/pressure alarm • Connection to LAE supervisory systems
• Available display unit: LCD-5S or RU33
115...230Vac RS485
data I/O
DI2 T3
Aux
NL
16(5)AMaximum total
current 30A
16(4)A 7(2)A 7(2)A7(2)A
AUX2AUX1
T2T1
DoorSwitch
Door
Aux Switch12...24Vac
AD2-28C2Q4E-A
DI212÷24Vac
Maximum total current 12A
PowerSupply
L
N
TTLLCD-5S
12(4)A12(8)A 8(3)A 7(2)A
Evaporator fan
Condenser fan
T3T2 T1
remote data I/0
Door
AUX 1
Aux
SPECIFICATIONS
FUNCTIONS B1S3E-A C2Q4E-A C3R5U-B
TEMPERATURE
INPUTS
THERMOSTAT √ √ √
EVAPORATOR √ √ √
AUXILIARY √ √
DOOR SWITCH INPUT VOLTAGE FREE CONTACT √ √ √
D12 AUX.
DIGITAL INPUTS
VOLTAGE FREE CONTACT √
12 ÷ 24VAC VOLTAGE √
DEFROST SYNCHRONISATION √
OUTPUTS
THERMOSTAT 15(5)A √ √ √
EVAPORATOR FANS √ √ √
DEFROST √ √ √
AUXILIARY 1 √ √
AUXILIARY 2 √
CONNECTIONSSCREW TERMINALS √ √
QUICK WITH M/F CONNECTORS √
POWER SUPPLY230VAC √ √
115VAC √
SERIAL PORTTTL √ √
RS485 √
10
LAE ELECTRONIC
CONTROLLERS
HUMIDITY
PRESSURE
HUMIDITY TRANSMITTERSTYPE HT2WAD
SENSOR TYPE Capacitive
OUTPUT SIGNAL 0÷1Vdc
RANGE 0%÷100%r.H
ACCURACY ±5%r.H. (25%÷75%r.H.)
SHEATH Ø14x40mm
PROTECTION IP65 (electronics)
OPERATING TEMPERATURE 0÷75°C (sensor) / 0÷50°C (electronics)
DIMENSIONS OF THE ENCLOSURE 110x53x75mm (electronics)
POWER SUPPLY 12Vdc, 0.2W
HUMIDITY AND TEMPERATURE TRANSMITTERTYPE HT2WSE
SENSOR TYPE Capacitive
OUTPUT SIGNAL RS485
RANGE 0%÷100%r.H / 0÷70°C
ACCURACY ±5%r.H. (25%÷75%r.H.) / ±0.3°C @ 25°C; ±1°C (0÷70°C)
SHEATH Ø14x40mm
PROTECTION IP65 (electronics)
OPERATING TEMPERATURE 0÷75°C (sensor) / 0÷50°C (electronics)
DIMENSIONS OF THE ENCLOSURE 110x53x75mm (electronics)
POWER SUPPLY 12Vdc, 0.2W
PRESSURE TRANSMITTERSTYPE PGT35
SENSOR TYPE Piezoresistive gauge
OUTPUT SIGNAL 4÷20mA
RANGE -0,5÷35,0 bar
ACCURACY max±1%FS (0÷50°C)
SHEATH Ø17x58 mm
CONNECTIONS mPm connector
PRESSURE PORT 7/16”-20UNF male, steel AISI 316L
PROTECTION IP65
AMBIENT TEMPERATURE -40÷100°C
POWER SUPPLY 8÷32Vdc
11
TAB4.2 SOFTWARE
LAE ELECTRONIC
MONI TORI NG, LOGGING AND PROGRAMMING SOFTWARE
• Overall plant monitoring
• Compatible with the wireless communication system
• Storage of temperature, humidity, pressure, alarms
• Display and printing in numerical and graphic form of stored data
• Export of stored data for Excel* or others
• Diagnostics with dynamic graphs of all analog inputs
• Virtual instrument for analysing the system and setting
regulator parameters
• Automatic sending or on demand of SMS to trace alarm status
• Connection to remote PC for tele-servicing via Internet
• Several languages available: English, German, Italian, Spanish, Polish etc
AVAILABLE OPTIONSSupervision of the refrigeration process in supermarkets, convenience stores,
shops, petrol stations, large kitchens, food factories, cruise ships etc.
APPLICATIONS• Computer with Windows XP/Vista* operating system installed
and properly running,minimum processor and memory as required
from Windows* version – USB port – Mouse – CD-ROM drive
• 1024x768 pixel screen resolution, 16-bit colour
• 1GB available on Hard Disk
• RS232 serial port (COM); an additional port is required if a GSM
modem is fitted
• In case of wireless communication with the controllers, modules
SWB-C and SWB-R are needed.
• Alternatively, an RS232-RS485 converter mod. SBC485 has to
be fitted in case of a hard-wired system.
• GSM modem for sending SMS
12
DAMPER ACTUATORS
ACTUATORS
PRODUCT SPECIFICATIONS
6 – 16Nm
0 – 90°
Spring Return Function
ON/OFF Control
24VAC/DC, 230VAC
TDF SERIES
PRODUCT SPECIFICATIONS
6 – 16Nm
0 – 90°
Spring Return Function
Modulating
24VAC, 230VAC
TAF SERIES
PRODUCT SPECIFICATIONS
2 – 4Nm
0 – 90°
ON/OFF Control
24VAC/DC, 230VAC
TD SERIES
PRODUCT SPECIFICATIONS
10 – 40Nm
0 – 90°
VAV Control
24VAC/DC, 230VAC
TV SERIES
PRODUCT SPECIFICATIONS
6 – 10Nm
0 – 90°
VAV Control
24VAC/DC, 230VAC
TV SERIES
PRODUCT SPECIFICATIONS100Nm6mmSpring Return FunctionON/OFF Control24VAC/DC, 230VAC
PRODUCT SPECIFICATIONS
10 – 40Nm
0 – 90°
ON/OFF Control
24VAC/DC, 230VAC
TD SERIES
PRODUCT SPECIFICATIONS
10 – 40Nm
0 – 90°
Modulating
24VAC/DC
TA SERIES
PRODUCT SPECIFICATIONS
6 – 10Nm
0 – 90°
ON/OFF Control
24VAC/DC, 230VAC
TD SERIES
PRODUCT SPECIFICATIONS
6 – 10Nm
0 – 90°
Modulating
24VAC/DC
TA SERIES
PRODUCT SPECIFICATIONS
2 – 4Nm
0 – 30° – 60° – 90°
ON/OFF Control
24VAC, 230VAC
TH SERIES
PRODUCT SPECIFICATIONS2 – 4Nm0 – 90°Spring Return FunctionON/OFF Control24VAC, 230VAC
13
MINI CIRCUIT BREAKERS
CIRCUIT BREAKERS
YDZ47-60YDZ47-60 is an all new high performance current limiting
device with the ability to disconnect short circuits of up to 10kA.
And the most economy which is the newest model in the 21st
Century. YDZ47-60 MCB has many merits of high protective grade
(up to IP20) high breaking capacity, good realiability of sensitive
action, convenient multi-pole assorting, long using life etc.
They are mainly used for overload and short circuit protection
within the circuit of AC 50Hz, 230V in single pole 400V in two,
three ans four poles of lighting distribution systems in industrial
and commercial. They are also used in turning on and off electric
apparatus and lighting circuits under the normal condition.
PROPERTIES
CHARACTER STANDARD RATED CURRENT (A) POLES (P) RATING VOLTAGE (V) BREAKING CAPACITY (A)
B
C
D
IEC-8981, 2, 3, 4, 5, 6, 10, 16,
20, 25, 32, 40, 50, 60A
1 230 / 240 10000
2, 3, 4 400 / 415 6000
IEC-947-21, 2, 3, 4, 5, 6, 10, 16,
20, 25, 32, 40, 50, 60A
1130 20000
230 / 240 10000
2, 3, 4
400 / 415 3000
230 / 240 20000
400 / 415 10000
440 6000
YDZ47-60 3P
YDZ47-60 2P
YDZ47-60 1P
YDZ47-60
14
RESIDUAL CURRENT CIRCUIT BREAKER
CIRCUIT BREAKERS
YF360-4P YF360-2P
SPECIFICATIONS
POLE NO. IN (A)
CAT.NO
I Δ N (MA)
30 100 300 500
4
25 DZ41030 DZ41100 DZ41300 DZ41500
40 DZ42030 DZ42100 DZ42300 DZ42500
63 DZ43030 DZ43100 DZ43300 DZ43500
SPECIFICATIONS
POLE
NO.
IN
(A)
CAT.NO
I Δ N (MA)
10 30 100 300 500
2
25 DZ21010 DZ21030 DZ21100 DZ21300 DZ21500
40 DZ22030 DZ22100 DZ22300 DZ22500
63 DZ23030 DZ23100 DZ23300 DZ23500
DIMENSIONSAPPLICATIONResidual Current Circuit Breaker provide the function of islation
switching and earth leakage protection of electrical circuits.
And also provide the indirect protection of the operator's body
against the dangerous effects of electric current and provide the
protection of the fire caused by the electrical circuit fault.
TECHNICAL DATASTANDARD IEC 1008, GB16916
RATED VOLTAGE (UN) 2 Pole: 230VAC
4 Pole: 400VAC
RATED CURRENT (IN) 25, 40, 63A
RATED RESIDUAL OPERATING CURRENT (IN)
10, 30, 100, 300, 500mA
RATED RESIDUAL NON-OPERATING CURRENT (IΔNO) 0.5 IΔn
RESIDUAL CURRENT OFF-TIME ≤0.1s
MINIMUM VALUE OF RATED MAKING AND BREAKING CAPACITY (IM) 630A
RATED CONDITIONAL SHORT-CIRCUIT CURRENT (INC)
In = 25.40A Inc = 1500A
In = 63A Inc = 3000A
ENDURANCE: ON LOAD 2000 cycles
OFF LOAD 2000 cycles
INSTALLATION• On Symmetrical DIN Rail
• Panel Mounting
YF360-III
15
CIRCUIT BREAKERS
R7 ISOLATED SWITCHES
R7 1P R7 2P R7 3P R7 4P
APPLICATIONIt’s used for industry, commercial and
residential circuit electrical wire, used
as mainly switch IEC947.3 (EN60947.3).
STRUCTURE CHARACTERISTICS• Dual-Function connected wire terminal
• With indicator for contact status
• Can hand lock
• Lock Bore diameter is 6mm
SPECIFICATION
RATED VOLTAGE 240/415V
FREQUENCY 50/60 Hz
SHORT-CIRCUIT BEARS TO SUFFER CAPACITY Connected to 100A, Fuse to 25kA
MAKING OR BREAKING CAPACITY 1.25In; 1.1Ue
USAGE CATEGORY AC22
CONNECTION WIRE CUT Max. 50mm²
PROTECTION GRADE IP40 (Install the term)
INSULATEAppearance of clear and definate switch position
according to DIN VDEO106
DIMENSIONSRATED CURRENT
40 R7-40/1 R7-40/2
63 R7-63/1 R7-63/2
80 R7-80/1 R7-80/2
100 R7-100/1 R7-100/2
RATED CURRENT
40 R7-40/3 R7-40/4
63 R7-63/4 R7-63/4
80 R7-80/4 R7-80/4
100 R7-100/3 R7-100/4
1
2
1
2
3
4
1
2
3
4
5
6
1
2
3
4
5
6
7
8
16
THREE POLE CONTACTORS
CONTACTORS
INSTANTANEOUS
AUXILIARY
CONTACTS
RATED
INSULATION
VOLTAGE
ACI
DUTY
0≥40°C
AC3
3 PHASE
AC3
1 PHASE
220V 380V 440V 575V 120V 230V
CATALOGUE
NAMEN / O N / C UI ITH IE
KWHP
KWHP
KWHP
KWHP
KWHP
KWHP
WEIGHT
KGAPPROVAL
SMC-09 1 1 1000V 20A 9A2.2
3
3.7
5
3.7
5
3.7
5
0.37
0.5
1.5
20.36
SMC-12 1 1 1000V 25A 12A3
4
5.5
7.5
5.5
7.5
5.5
7.5
0.55
0.75
1.5
20.36
SMC-18 1 1 1000V 32A 15A3.7
5
7.5
10
7.5
10
7.5
10
0.75
1
2.2
30.37
SMC-22 1 1 1000V 40A 22A5.5
7.5
11
15
11
15
11
15
1.5
2
3.7
50.37
SMC-32 2 2 1000V 50A 32A7.5
10
15
20
15
20
15
20
2.2
3
4
5.50.48
SMC-40 2 2 1000V 60A 42A11
15
19
25
19
25
19
25
3
4
5.5
7.50.48
SMC-50 2 2 1000V 80A 55A15
20
30
40
30
40
30
401.3
SMC-65 2 2 1000V 100A 65A19
25
33
45
33
45
33
451.3
SMC-80 2 2 1000V 110A 80A22
30
37
50
37
50
37
501.3
SMC-85 2 2 1000V 135A 105A25
35
45
60
55
75
55
751.3
NOTE SMC-32 ~ SMC85 includes of 2PCS SMC-D11
CATALOG NAME
APPLICABLE CONTACTORS
AUXILIARY N/O
CONTACTS N/C
INSULATION VOLTAGE
THERMAL CURRENT
WEIGHT KG APPROVAL
SMC-D11SMC-09 TO
SMC-851 1 660V 10A 0.034
NOTE SMC-09~SMC-22 includes 1PCS SMC-D11 only
10A MAX and 600VAC
UI 600V
ITH 10A
SMC-09 SMC-12 SMC-32 SMC-40 SMC-50 SMC-65 SMC-85
AUXILIARY CONTACTS BLOCKS / SMC-D11
“SMC” – SERIES 9A TO 105A (AC3)
17
INSTANTANEOUS
AUXILIARY
CONTACTS
RATED
INSULATION
VOLTAGE
ACI
DUTY
0≥40°C
AC3
3 PHASE
AC3
1 PHASE
220V 380V 440V 575V 120V 230V
CATALOGUE
NAMEN / O N / C UI ITH IE
KWHP
KWHP
KWHP
KWHP
KWHP
KWHP
WEIGHT
KGAPPROVAL
C-06D10
C-06D01
1 -
- 11000V 16A 9A
2.2
3
3.7
5
3.7
5
3.7
5
0.2
1/3
1.1
1.50.177
C-09D10
C-09D01
1 -
- 11000V 20A 9A
2.2
3
5.5
7.5
5.5
7.5
5.5
7.5
0.37
0.5
1.5
20.350
C-11D10
C-11D01
1 -
- 11000V 25A 12A
3
4
5.5
7.5
5.5
7.5
5.5
7.5
0.55
0.75
1.5
20.350
C-12D10
C-12D01
1 -
- 11000V 25A 16A
4
5.5
7.5
10
7.5
10
7.5
10
0.75
1
2.2
30.350
C-18D10
C-18D01
1 -
- 11000V 32A 22A
5.5
7.5
11
15
11
15
11
15
1.5
2
3.7
50.350
C-25D10
C-25D01
1 -
- 11000V 40A 32A
7.5
10
15
20
15
20
15
20
2.2
3
4
5.50.525
C-35D10
C-35D01
1 -
- 11000V 50A 42A
11
15
19
25
19
25
19
25
3
4
5.5
7.50.550
C-45D11 1 1 1000V 60A 55A15
20
30
40
30
40
30
401.100
C-44D11 1 1 1000V 80A 65A19
25
33
45
33
45
33
451.100
C-65D11 1 1 1000V 90A 80A22
30
37
50
37
50
37
501.100
C-80D11 1 1 1000V 125A 105A25
35
45
60
55
75
55
751.100
C-100D11 1 1 1000V 130A 110A30
40
55
75
55
75
60
801.430
NOTE SMC-32 ~ SMC85 includes of 2PCS SMC-D11
THREE POLE CONTACTORS
CONTACTORS
C-06D10 C-12D10 C-18D10 C-25D10 C-35D10 C-45D11 C-80D11
“C” – SERIES 9A TO 100A (AC3)
18
TH-12T3.50
THERMAL OVERLOAD RELAYS
CONTACTORS
THERMAL OVERLOAD RELAYS
“BTH”-SERIES 15A to 126A
CATALOGUE
NAME
RELAY SETTING
RANGE RC (FLC) A
STANDARD
A
CONTACTORS WEIGHT KG APPROVAL
BTH-60 12-18A 15A C-45D11 0.427
BTH-60 18-26A 22A C-45D11 0.427
BTH-60 26-40A 33A C-45D11 0.427
BTH-60 33-50A 41A C-45D11 0.427
BTH-60 43-65A 54A C-45D11 0.427
BTH-80 54-80A 67A C-45D11 0.427
BTH-80 64-96A 80A C-80D11(100D11) 0.427
BTH-80 85-126A 105A C-100D11 0.427
BTH-60
BTH-80
TH - 12 T 3.5 0 1 2 3 4
NTH - 17 2P S 1 2 3
1. CURRENT RATING (max.)
0.5 0.75 1.05 1.45 1.9 2.5 3 4 5 6.5
8 11 14 15 17 21 25 28 32 38 44
2. PHASE-FAILURE PROTECT
2P 2 Heaters
3P Phase-Failure
3. SEPARATE BLOCKS
NONE Normal
S Install
1. TYPE
12
20
60
120
3. CURRENT RATING (MEAN)
12 0.8 1.2 2.1 3.5 5 6.5
9 11 15
20 2.1 3.5 6.5 9 11 15 22 30 41
60 30 41 54 67 80
120 80 105 130
4. REAR CONNECTOR
NONE S-C Series
O C-Series
2. LOAD PLUG
NONE Normal
T Install
NTH-172PS
MODEL DESIGNATION
MODEL DESIGNATION
“BTH”SERIES 15A TO 126A• Compensated and Differential Overload Relays
• With 1 N/O + 1 N/C electrically Separated Auxillary Contacts
• For direct connection with “C”– Series Contactors
BTH SERIES
19
NMS MANUAL MOTOR STARTERWith thermal overload and magnetic
short circuit releases.
CONTACTORS
MANUAL MOTOR STARTER
NMSB - 4.0 1 2
MODEL DESIGNATION
2. CURRENT RATING
0.63 1.0 1.6 2.5 4.0
6.3 10 15 25
1. TYPE
NMS Open
NMSB Moulded Plastic Enclosure
TYPE AMPERE SETTING WEIGHT (Kg)
MAX. BACK-UP FUSE (SLOW)A
3X220V 3X380V 3X440V 3X550V 3X660V 3X240V
3X425V (3X690V)
APPROVAL
NMS 0.63 0.40 – 0.63 0.230
No Back-up fuse
required, irrespective
of prospective
short-circuit current
Breaking Capacity
10KA at 3x220/240V
6KA at 3x380/440V
2.5A at 3x600V
NMS 1.0 0.63 – 1.0 0.230
NMS 1.6 1.0 – 1.6 0.230
NMS 2.5 1.6 – 2.5 0.230
NMS 4.0 2.5 – 4.0 0.230
NMS 6.3 4.0 – 6.3 0.230
NMS 10.0 6.3 – 10 0.230
NMS 15.0 10 – 16 0.230
NMS 25.0 15 – 25 0.230
NEUTRAL/PROTECTIVE CONDUCTOR(PEN)BAREnclosures NMSB can be fitted with a
second neutral/protective conductor(PEN)bar.
MOULDED PLASTIC ENCLOSURE NMSB (IP56)As enclosure NMSB, however with
seal and push-button diaphragm.
Degree of protection IP56.
INSTANTANEOUS AUXILIARY CONTACT BLOCKS (1PER BREAKER)
NMSB-4.0
NMS-15
NAS-11 NMSB-6.3 NMSB-46
NMS-15
20
MS1-25D/35D
ENCLOSURES OF MAGNETIC STARTERS – MS1 IP65
CONTACTORS
MS1-09D/11D/12D/18D
DIMENSIONS (MM)
21
ENCLOSURES OF MAGNETIC STARTERS MS1 IP65
CONTACTORS
MS1-25D/35D-R
MS1-09D/11D/12D/18D-R
DIMENSIONS (MM)
22
ENCLOSURES OF MAGNETIC STARTERS MSP IP42
CONTACTORS
MSP21
MSP11
DIMENSIONS (MM)
23
YF360 - 4P
DATALOGGERS
DATALOGGERS
BUILT-IN RS232
BUILT-IN RS232 INTERFACE DUAL TEMP. +RH WITH DISPLAY 88395
BUILT-IN RS232 INTERFACE DUAL TEMP. 88393/88394
RECORDING AIR TEMP. & EXT.TEMP (W/CONTACT PROBE) BUILD-IN RS232
INTERFACE W/O LOGGER CRADLE TO SETUP OR DOWNLOAD
3 STARTING MODES
1) Key start or stop
2) Schedule to start
3) Immediately start meets
IP65 waterproof rating
2 WAYS TO SETUP/DOWNLOAD
1) To PC: RS232/USB Cable
2) With Logger Printer 9801
W/Both Phonejacks cable: without
linking to PC Print available user
friendly software, easy to
set HI/LO ALM
TEMP. RANGE: -40~85°C, -40~185°C
EXTERNAL TEMP. RANGE -40 ~100°C (-40~212°F)
POWER BATTERY 3.0V Lithium Battery (CR2)
ACCURACY: TEMP.±0.6°C (-20~50°C)
±1.2°C (-40~20°C, 51~85°C)
MEMORY16000 points
(Temp. 8000 + Ext. Temp. 8000)
LCD DISPLAY Size: 13.5 x 33mm
DIMENSIONS (MM) 75.5mm x 53mm x 23.5mm (H x W x T)
LED SIGNAL Red (HI,LO Alarm) / Yellow (Record)
STANDARD PACKING Logger, Battery and Manual
OPTIONAL
RS232/USB cable W/Software or
9801 Logger Printer or RS232 to USB
converter to most PC comm. port.
RECORDING AIR TEMP. & EXT.TEMP (W/CONTACT PROBE)
BUILD-IN RS232 INTERFACE W/O LOGGER CRADLE TO SETUP OR DOWNLOAD
3 STARTING MODES
1) Key start or stop
2) Schedule to start
3) Immediately start meets
IP54 water resistant rating
2 WAYS TO SETUP/DOWNLOAD
1) To PC: RS232/USB Cable
2) With Logger Printer 9801
W/Both Phonejacks cable: without
linking to PC Print available user
friendly software, easy to
set HI/LO ALM
TEMP. RANGE -40~85°C, -40~185°C
EXTERNAL TEMP. RANGE -40~100°C (-40~212°F)
RH RANGE 0-100%
ACCURACY ±3% (10-90%), ±5% others
POWER BATTERY 3.0V Lithium Battery (CR2)
ACCURACY: TEMP. ±0.6°C (-20~50°C)
±1.2°C (-40~20°C, 51~85°C)
MEMORY16000points
(Air T.5333-Ext. T.53333+RH5333)
LCD DISPLAY Size: 13.5 x 33mm
DIMENSIONS (MM) 75.5mm x 53mm x 23.5mm (H x W x T)
LED SIGNAL Red (HI,LO Alarm) / Yellow (Record)
STANDARD PACKING Logger, Battery and manual
OPTIONALRS232/USB cable W/Software or 9801
Logger Printer or RS232 to USB converter
to most PC comm.port.
24
FANS
THERMAL MANAGEMENT
SPECIFICATIONS
RATED
VOLTAGE
(VAC)
FREQU.
(Hz)
INPUT
POWER
(W)
RATED
CURRENT
(A)
LOCKED
CURRENT
(A)
SPEED
(RPM)
MAX.
AIRFLOW
(m³/min.)
MAX.
AIRFLOW
(CFM)
MAX.
PRESSURE
(mm H²0)
MAX.
PRESSURE
(inch H²0)
NOISE WEIGHT
MODEL
S063-1-HWB115 50 5 0,042 0,042 2.400 0,23 8,10 1,8 0,07 27 0,14
115 60 4 0,035 0,040 3.000 0,29 10,24 2,8 0,11 28 0,14
S063-2-HWB230 50 5 0,022 0,022 2.400 0,23 8,10 1,8 0,07 27 0,14
230 60 4 0,016 0,020 3.000 0,29 10,24 2,8 0,11 28 0,14
SPECIFICATIONS
RATED
VOLTAGE
(VAC)
FREQU.
(Hz)
INPUT
POWER
(W)
RATED
CURRENT
(A)
LOCKED
CURRENT
(A)
SPEED
(RPM)
MAX.
AIRFLOW
(m³/min.)
MAX.
AIRFLOW
(CFM)
MAX.
PRESSURE
(mm H²0)
MAX.
PRESSURE
(inch H²0)
NOISE WEIGHT
MODEL
S085-1-HWB115 50 15 0,15 0,16 2.600 0,59 21,0 4,0 0,16 32 0,26
115 60 11 0,12 0,13 3.100 0,68 24,0 4,5 0,22 35 0,26
S085-2-HWB230 50 16 0,08 0,09 2.600 0,59 21,0 4,0 0,16 32 0,26
230 60 14 0,07 0,08 3.100 0,68 24,0 5,5 0,22 35 0,26
S085-1-LWB115 50 14 0,14 0,15 1.900 0,40 15,0 2,0 0,08 28 0,26
115 60 11 0,12 0,13 2.400 0,50 18,0 3,5 0,14 31 0,26
S085-2-LWB230 50 16 0,07 0,08 1.900 0,40 15,0 2,0 0,08 28 0,26
230 60 14 0,06 0,07 2.400 0,50 18,0 3,5 0,14 31 0,26
S063 SERIES AC-FAN / AC-LÜFTER 60x60x30MM
S085 SERIES AC-FAN / AC-LÜFTER 80x80x25MM
S088 SERIES AC-FAN / AC-LÜFTER 80x80x38MM
SPECIFICATIONS
RATED
VOLTAGE
(VAC)
FREQU.
(Hz)
INPUT
POWER
(W)
RATED
CURRENT
(A)
LOCKED
CURRENT
(A)
SPEED
(RPM)
MAX.
AIRFLOW
(m³/min.)
MAX.
AIRFLOW
(CFM)
MAX.
PRESSURE
(mm H²0)
MAX.
PRESSURE
(inch H²0)
NOISE WEIGHT
MODEL
S088-1-HWB115 50 12 0,14 0,16 2.600 0,59 21,0 4,0 0,16 32 0,28
115 60 9 0,12 0,13 3.100 0,68 24,0 4,5 0,22 36 0,28
S088-2-HWB230 50 14 0,07 0,09 2.600 0,59 21,0 4,0 0,16 32 0,28
230 60 12 0,06 0,08 3.100 0,68 24,0 5,5 0,22 36 0,28
S088-1-LWB115 50 12 0,12 0,15 1.900 0,40 15,0 2,0 0,10 28 0,28
115 60 9 0,10 0,13 2.400 0,50 18,0 3,5 0,16 32 0,28
S088-2-LWB230 50 14 0,06 0,08 1.900 0,40 15,0 2,0 0,10 28 0,28
230 60 1 0,05 0,07 2.400 0,50 18,0 3,5 0,16 32 0,28
5
5-A
5-B
25
THERMAL MANAGEMENT
FANS
SPECIFICATIONS
RATED
VOLTAGE
(VAC)
FREQU.
(Hz)
INPUT
POWER
(W)
RATED
CURRENT
(A)
LOCKED
CURRENT
(A)
SPEED
(RPM)
MAX.
AIRFLOW
(m³/min.)
MAX.
AIRFLOW
(CFM)
MAX.
PRESSURE
(mm H²0)
MAX.
PRESSURE
(inch H²0)
NOISE WEIGHT
MODEL
S128-1-HWB115 50 14 0,20 0,27 2.700 2,60 92,0 8,0 0,32 42 0,53
115 60 12 0,16 0,23 3.100 3,00 106,0 8,0 0,32 46 0,53
S128-2-HWB230 50 17 0,10 0,14 2.700 2,60 92,0 8,0 0,32 42 0,53
230 60 15 0,08 0,12 3.100 3,00 106,0 8,0 0,32 46 0,53
S128-1-MWB115 50 14 0,18 0,20 2.500 1,30 85,0 6,5 0,26 40 0,53
115 60 12 0,17 0,19 2.750 2,40 92,0 7,0 0,18 42 0,53
S128-2-MWB230 50 17 0,09 0,10 2.500 2,40 85,0 6,5 0,26 40 0,53
230 60 15 0,08 0,09 2.750 2,60 92,0 7,0 0,18 42 0,53
S128-1-LWB115 50 14 0,16 0,18 2.100 2,10 75,0 4,0 0,16 36 0,53
115 60 12 0,15 0,16 2.300 2,30 82,0 4,1 0,16 38 0,53
S128-2-LMB230 50 17 0,08 0,09 2.100 2,10 75,0 4,0 0,16 36 0,53
230 60 15 0,07 0,08 2.300 2,30 82,0 4,1 0,16 38 0,53
S128 SERIES AC-FAN / AC-LÜFTER 120x120x38MM
RS128 SERIES AC-FAN / AC-LÜFTER 120x120x38MM / REVERSE AIR-DIRECTION
SPECIFICATIONS
RATED
VOLTAGE
(VAC)
FREQU.
(Hz)
INPUT
POWER
(W)
RATED
CURRENT
(A)
LOCKED
CURRENT
(A)
SPEED
(RPM)
MAX.
AIRFLOW
(m³/min.)
MAX.
AIRFLOW
(CFM)
MAX.
PRESSURE
(mm H²0)
MAX.
PRESSURE
(inch H²0)
NOISE WEIGHT
MODEL
RS128-1-HWB115 50 13 0,20 0,22 2.700 2,40 85,0 8,0 0,32 45 0,53
115 60 11 0,19 0,20 3.100 2,80 99,0 8,5 0,33 47 0,53
RS128-2-HWB230 50 17 0,10 0,11 2.700 2,40 85,0 8,0 0,32 45 0,53
230 60 15 0,09 0,10 3.100 2,80 99,0 8,5 0,33 47 0,53
RS128-1-MWB115 50 13 0,18 0,20 2,500 2,20 78,0 6,0 0,24 43 0,53
115 60 11 0,17 0,19 2,750 2,40 85,0 6,5 0,26 45 0,53
RS128-2-MWB230 50 17 0,09 0,10 2,500 2,20 78,0 6,0 0,24 43 0,53
230 60 15 0,08 0,09 2,750 2,40 85,0 6,5 0,26 45 0,53
RS128-1-LWB115 50 13 0,16 0,18 2,100 1,90 67,0 3,8 0,15 36 0,53
115 60 11 0,15 0,16 2,300 2,10 75,0 4,0 0,16 38 0,53
RS128-2-LMB230 50 17 0,08 0,09 2,100 1,90 67,0 3,8 0,15 36 0,53
230 60 15 0,07 0,08 2,300 2,10 75,0 4,0 0,16 38 0,53
8
8-A
26
FANS
THERMAL MANAGEMENT
SPECIFICATIONS
RATED
VOLTAGE
(VAC)
FREQU.
(Hz)
INPUT
POWER
(W)
RATED
CURRENT
(A)
LOCKED
CURRENT
(A)
SPEED
(RPM)
MAX.
AIRFLOW
(m³/min.)
MAX.
AIRFLOW
(CFM)
MAX.
PRESSURE
(mm H²0)
MAX.
PRESSURE
(inch H²0)
NOISE WEIGHT
MODEL
MS175-1-HWB115 50 42 0,52 0,88 2.800 5,5 195 14,0 0,55 49 1,10
115 60 42 0,47 0,75 3.250 6,5 230 16,0 0,63 53 1,10
MS175-2-HWB230 50 42 0,25 0,43 2.800 5,5 195 14,0 0,55 49 1,10
230 60 42 0,23 0,37 3.250 6,5 230 16,0 0,63 53 1,10
SPECIFICATIONS
RATED
VOLTAGE
(VAC)
FREQU.
(Hz)
INPUT
POWER
(W)
RATED
CURRENT
(A)
LOCKED
CURRENT
(A)
SPEED
(RPM)
MAX.
AIRFLOW
(m³/min.)
MAX.
AIRFLOW
(CFM)
MAX.
PRESSURE
(mm H²0)
MAX.
PRESSURE
(inch H²0)
NOISE WEIGHT
MODEL
S175-1-HWB115 50 26 0,24 0,58 2.850 5,8 205 14,0 0,55 61 1,08
115 60 30 0,25 0,58 3.400 6,8 241 18,5 0,73 66 1,08
S175-2-HWB230 50 26 0,11 0,58 2.850 5,8 205 14,0 0,55 61 1,08
230 60 31 0,13 0,58 3.400 6,8 241 18,5 0,73 66 1,08
MS175 SERIES AC-FAN / AC-LÜFTER Ø172x55MM / METAL-IMPELLER
S175 SERIES AC-FAN / AC-LÜFTER Ø172x55MM
S170 SERIES AC-FAN / AC-LÜFTER Ø172x150x51MM / THERMAL PROTECTION
SPECIFICATIONS
RATED
VOLTAGE
(VAC)
FREQU.
(Hz)
INPUT
POWER
(W)
RATED
CURRENT
(A)
LOCKED
CURRENT
(A)
SPEED
(RPM)
MAX.
AIRFLOW
(m³/min.)
MAX.
AIRFLOW
(CFM)
MAX.
PRESSURE
(mm H²0)
MAX.
PRESSURE
(inch H²0)
NOISE WEIGHT
MODEL
S170-1-HWB115 50 39 0,38 0,75 2.900 6,8 240 17,0 0,67 55 1,05
115 60 38 0,34 0,76 3.400 8,3 293 23,0 0,90 60 1,05
S170-2-HWB230 50 38 0,18 0,38 2.900 6,8 240 17,0 0,67 55 1,05
230 60 38 0,17 0,38 3.400 8,3 293 23,0 0,90 60 1,05
11
11-A
11-B
27
UF133 – APA SERIES
S220 SERIES AC-FAN / AC-BACKWARD-CURVED-FAN / RÜCKWÄRTSGEKRÜMMTER-AC-LÜFTER Ø223x64MM / THERMAL PROTECTION
S180 SERIES AC-FAN / AC-AXIAL-FAN / AC-AXIALLÜFTER / Ø180x65MM / THERMAL PROTECTION
THERMAL MANAGEMENT
FANS
SPECIFICATIONS
RATED
VOLTAGE
(VAC)
FREQU.
(Hz)
INPUT
POWER
(W)
RATED
CURRENT
(A)
LOCKED
CURRENT
(A)
SPEED
(RPM)
MAX.
AIRFLOW
(m³/min.)
MAX.
AIRFLOW
(CFM)
MAX.
PRESSURE
(mm H²0)
MAX.
PRESSURE
(inch H²0)
NOISE WEIGHT
MODEL
UF133(72)APA
11H1S2A
115 50 38 0,50 0,83 2.780 4.66 335 16,6 0,65 50 0.9
115 60 37 0,43 0,72 3.200 5.33 370 22,4 0,88 60 0.9
UF133(72)APA
23H1S2A
230 50 36 0,24 0,39 2.780 4.66 335 16,6 0,65 50 0.9
230 60 35 0,21 0,34 3.200 5.33 370 22,4 0,88 60 0.9
SPECIFICATIONS
RATED
VOLTAGE
(VAC)
FREQU.
(Hz)
INPUT
POWER
(W)
RATED
CURRENT
(A)
LOCKED
CURRENT
(A)
SPEED
(RPM)
MAX.
AIRFLOW
(m³/min.)
MAX.
AIRFLOW
(CFM)
MAX.
PRESSURE
(mm H²0)
MAX.
PRESSURE
(inch H²0)
NOISE WEIGHT
MODEL
S225-1-HWB115 50 90 0,77 1,19 2.500 14,0 500 15,0 1,4 65 1,30
115 60 117 0,98 1,22 2.650 15,0 530 16,0 1,5 70 1,30
S225-2-HWB230 50 90 0,40 0,60 2.500 14,0 500 15,0 1,4 65 1,30
230 60 117 0,50 0,58 2.650 15,0 530 16,0 1,5 70 1,30
SPECIFICATIONS
RATED
VOLTAGE
(VAC)
FREQU.
(Hz)
INPUT
POWER
(W)
RATED
CURRENT
(A)
LOCKED
CURRENT
(A)
SPEED
(RPM)
MAX.
AIRFLOW
(m³/min.)
MAX.
AIRFLOW
(CFM)
MAX.
PRESSURE
(mm H²0)
MAX.
PRESSURE
(inch H²0)
NOISE WEIGHT
MODEL
S280-1-HWB115 50 76 0,70 1,23 2.750 9,5 335 7,5 0,3 62 1,20
115 60 75 0,71 1,23 3.100 11,0 388 10,0 0,4 65 1,20
S280-2-HWB230 50 76 0,35 0,54 2.750 9,5 335 7,5 0,3 62 1,20
230 60 75 0,40 0,54 3.100 11,0 388 10,0 0,4 65 1,20
16-A
16-B
28
80x80MM ART.-NR. G80-18 60x60MM ART.-NR. G60-4
THERMAL MANAGEMENT
FANS
ACCESSORIES / METAL FINGER GUARDS 18
119x119MM ART.-NR. G109-15A 92x92MM ART.-NR. G92-16
29
ELECTRONIC FAN SPEED CONTROL
FAN SPEED CONTROLS
ELECTRONIC SPEEDCONTROLLER FOR SINGLE PHASE MOTORSCURRENT MAX. 4 AMPS
POWEER SUPPLY 230V-1, Ph-50/60 Hz, min. 180V, max. 260V
EU-CONFORMITY CE – SIGN
Electronical Filter according EMV-89/336/EEC and ICE801-2 cl.4
CONNECTIONS: POWER SUPPLY
Removable screw-type connectionsfor max. 2.5mm²
SENSORS
Removable screw-type connections for max. 2.5mm²
PRODUCT INFORMATION
TECHNICAL DATA POWER SUPPLY APPLICATION
AMBIENT TEMPERATURES
Temperatures -20ºC ./. +55ºC
Humidity <90% r.H. not condensing
ANALOGUE – INPUT
1 x Presssure Transducer 4 – 20mA
1 x Temperature Sensor NTC (10 kOhm)
Max. Starting Current
2 x Nominal Current for max. 10 sec
ADR 40 – BOARD TO BE INSTALLED
IN CABINETS IP 24
Dimensions W x H x D : 90 x 85 x 40 mm
ADR 40 DP – IN ALU DIE CAST BOX, IP 55
Dimensions W x H x D : 97 x 120 x 60 mm
ADR 40 PP – IN PLASTIC BOX IP 54
Dimensions: W x H x D : 170 x 150 x 50 mm
SINGLE PHASE 230 Volts, 50 – 60 Hz
MIN. POWER SUPPLY 180 Volts
PRESSURE RANGE WITH PRESSURE TRANSDUCER
Min. +10 bars Max. +40 bars
TEMPERATURE RANGE WITH NTC-SENSOR
Min. -20°C Max. +100°C
PRESSURE CONTROL
The setup of the requested set points and also
the range of the proportional band has to be
done by adjusting two trimmer which are placed
on the board.
TEMPERATURE CONTROL
The setup of the requested set points and
also the range of the proportional band
has to be done by adjusting two trimmer
which are placed on the board.
The adjustment of the trimmer is always
for the connected pressure transducer or
the temperatur sensor.
NO EXTERNAL REMOTE CONTROL NECESSARY
CHILLER / HEAT PUMP
The Speed Controller ADR 40
can be used in chiller applications
(increasing temperature = increasing speed)
as well as heat pump applications
(increasing temperature = decreasing speed).
Heat pump applications are possible to control
only by using pressure transducers 4-20 mA.
By using ADR 40 in heat pump applications a
bridge has to be made on the NTC connection.
In pressure control for safety reasons or particular
requirements a NTC-Sensor could be installed
in addition to the pressure transducer. In case
that measured temperatures exceed 90°C the
speed controller will stop the motor and drop in
again according to the measured pressure when
temperature undergoes 90°C.
At new starts motors are always forced for
some seconds to run at 70% of the speed.
In case of breakdowns of the board the
ADR fails to safe.
FUNCTION DIAGRAM CHILLERBETRIEB
SET PROP
ADR 40
%
ºC/BARmin
ºC/BARmax
0
min
(max + min)/2
max
SET
30
ELECTRONIC FAN SPEED CONTROL
FAN SPEED CONTROLS
ELECTRONIC FAN SPEED CONTROLLER PRESSURE – OR TEMPERATURE CONTORLS FOR SINGLE– AND THREE PHASE MOTORS CURRENT MAX. 8 AMPS
POWER SUPPLY: 230V/400V-3 Ph – 50/60 Hz
230V-1 Ph – 50/60 Hz
EU-CONFORMITY CE
Electronical Filter according EMV - 89/336/EEC and ICE801-2 cl.4
CONNECTIONS POWER SUPPLY
Removable screw-type connectionsfor max. 16mm²
SENSORS
Removable screw-type connections for max. 2.5mm²
PRODUCT INFORMATION
TECHNICAL DATA INTERGRATED SOFTWARE ACCESSORIES
AMBIENT TEMPERATURES
Temperatures -10ºC ./. -55ºC
Humidity less than 90% R.F. not condensing
ANALOGUE – INPUT
2 x Multifunction, 4 – 20mA
0 – 20mA
0 – 10V, NTC (selectable)
SERIAL INTERFACE
System Micronova Type RS 422 or RS 485
and connection to Modern, GCM
MAX. STARTING – CURRENT
Double of nominal data for max. 10 sec
AVAILABLE MODELS:
ADR 80 – BOARD IP 24
Dimensions W x H x D : 198 x 160 x 55 mm
ADR 80 DP – IN HOUSE
Dimensions W x H x D : 315 x 255 x 180 mm
MODEL "DP" – IP 55
PROGRAMMABLE BY USING
MULTILINGUAL LCD – DISPLAY
LANGUAGES
English, German, Italian
POWER SUPPLY
Single – or three Phase
DUALSET – CONTROL (VERSION 4)
Also with two different sensors
AVAILABLE REFRIGERANT DATA
R22, R134A, R407C, R404A, R507
PRESSURE CONTROL
Data Input in Bar or ºC
TEMPERATURE CONTROL
between -20ºC to 80ºC
SPEED REGULATION WITH EXTERNAL CONTROL
Regulation by external signal 0-10V
PROGRAMMABLE OUTPUT – VOLTAGE
Maximum 0% to 100%
Minimum 0% to 100%
FAN – START WITH 100%
Programmable between 0 to 10 sec
IDENTIFYING POWER- FACTOR (COSΦ)
OF THE MOTOR
For improvement of the control
SENSOR AND / OR PRESSURE – TRANSDUCER
Programmable number, input-signal and max.
working limits.
NETWORK SOFTWARE
All ADR – controllers can be used and
adjusted externally by using the microvision
network software.
THE PRINCIPLES OF ADR CONTROL
ACCESSORIES
REMOTE – CONTROL LCD 2000
With 4 push-buttons, two-lines – Display with
16 digits, height 5mm, for installation in front
door, IP 55 including connecting cord 0.9m.
PMT – PRESSURE TRANSDUCER WITH
7/16UNF FEMALE THREAD SCHRADER
4 – 20mA, working-pressure: 7,18 or 30bar.
PMT-V – PRESSURE TRANSDUCER WITH
7/16UNF FEMALE THREAD SCHRADER
0 – 10V, working-pressure: 7,18 or 30bar.
NTC – TEMPERATURE-SENSOR
Standard Length: 6m
SWPC – SOFTWARE "MICROVISION"
Software for Supervision on Windows™
Base and Graphic Illustration.
REMOTE – CONTROL BY MODERN
Software for Single Remote-Control or
adjustment by PC.
DP – HOUSING IP 55
Prepared for installation of LCD-Display
c/w setting material.
Start Set
ProprtionalBand
Max
Pressure orTemperature
%min
%max
max
Speed
ADR 80
31
ELECTRONIC FAN SPEED CONTROL
FAN SPEED CONTROLS
ELECTRONIC FAN SPEED CONTROLLER PRESSURE – OR TEMPERATURE CONTROLS FOR SINGLE – AND THREE PHASE MOTORSCURRENT MAX. 23 AMPS
POWER SUPPLY 230V/400V-3 Ph – 50/60 Hz
230V-1 Ph – 50/60 Hz
EU-CONFORMITY CE – SIGN
Electronical Filter according EMV – 89/336/EEC and ICE801-2 cl.4
CONNECTIONS POWER SUPPLY
Removable screw-type connectionsfor max. 16mm²
SENSORS
Removable screw-type connections for max. 2.5mm²
PRODUCT INFORMATION
TECHNICAL DATA INTERGRATED SOFTWARE ACCESSORIES
AMBIENT TEMPERATURES
Temperatures -10ºC ./. -55ºC
Humidity less than 90% R.F. not condensing
INPUT 1 x potential-free
ANALOGUE – INPUT
2 x Multifunction, 4 – 20mA
0 – 20mA
0 – 10V, NTC (selectable)
SERIAL INTERFACE:
System Micronova Type RS 422 or RS 485
and connection to Modern, GCM
MAX. STARTING – CURRENT
Double of nominal data for max. 10 sec
AVAILABLE MODELS
ADR 80 – BOARD IP 24
Dimensions W x H x D: 198 x 190 x 87 mm
ADR 80 DP – IN HOUSE
Dimensions W x H x D: 315 x 255 x 230 mm
MODEL "DP" – IP 55
PROGRAMMABLE BY USING
MULTILINGUAL LCD – DISPLAY
LANGUAGES
English, German, Italian
POWER SUPPLY
Single – or three Phase
DUALSET – CONTROL (VERSION 4)
Also with two different sensors
AVAILABLE REFRIGERANT DATA
R22, R134A, R407C, R404A, R507
PRESSURE CONTROL
Data Input in Bar or ºC
TEMPERATURE CONTROL
between -20ºC to 80ºC
SPEED REGULATION WITH EXTERNAL CONTROL
Regulation by external signal 0-10V
PROGRAMMABLE OUTPUT – VOLTAGE
Maximum 0% to 100%
Minimum 0% to 100%
FAN – START WITH 100%
Programmable between 0 to 10 sec
IDENTIFYING POWER – FACTOR (COSΦ)
OF THE MOTOR
For improvement of the control
SENSOR AND / OR PRESSURE – TRANSDUCER
Programmable number, input-signal and max.
working limits.
NETWORK SOFTWARE
All ADR – controllers can be used and
adjusted externally by using the microvision
network software.
THE PRINCIPLES OF ADR CONTROL
ACCESSORIES
REMOTE – CONTROL LCD 2000
With 4 push-buttons, two-lines – Display with
16 digits, height 5mm, for installation in front
door, IP 55 including connecting cord 0.9m.
PMT – PRESSURE TRANSDUCER WITH
7/16UNF FEMALE THREAD SCHRADER
4 – 20mA, working-pressure: 7,18 or 30bar.
PMT–V – PRESSURE TRANSDUCER WITH
7/16UNF FEMALE THREAD SCHRADER
0 – 10V, working-pressure: 7,18 or 30bar.
NTC – TEMPERATURE-SENSOR
Standard Length: 6m
SWPC – SOFTWARE "MICROVISION"
Software for Supervision on Windows™
Base and Graphic Illustration.
REMOTE – CONTROL BY MODERN
Software for Single Remote-Control
or adjustment by PC.
DP – HOUSING IP 55
Prepared for installation of LCD-Display
c/w setting material.
Start Set
ProprtionalBand
Max
Pressure orTemperature
%min
%max
max
Speed
ADR 230
32
ELECTRONIC FAN SPEED CONTROL
FAN SPEED CONTROLS
REMOTE – CONTROL WITH LCD – DISPLAY APPLICATIONS:Boards with Microprocessor
FOR EXAMPLE
• Boards CB 2000, CB 1000 (MP0606)
• Controller ADR 70, 80 and 230
PRODUCT INFORMATION
TECHNICAL DATA INTERGRATED SOFTWARE
TECHNICAL DATA DISPLAY LCD 2000
INDICATOR
LCD – Display
2 lines with each 16 digits per line
Digit Height: 5mm
CONNECTION WITH BOARD
Connection cable 0.9m, max. length 4m
POWER SUPPLY
By connecting cable with the board.
AMBIENT TEMPERATURES
Temperatures 0ºC – 60ºC
Humidity less than 90% R.F. not condensing
PROTECTION DISPLAY
With front panel installation IP 55
HOUSING
Of robust, not flammable plastic.
DIMENSIONS OF DISPLAY
Frontal: 14.5 cm x 3.7 cm, depth: 1.5 cm
PUSH-BUTTONS FOR USAGE AND PROGRAMMING
Numbers: 4
LED – INDICATOR FUNCTION AND STATUS:
Numbers: 2
OPTION: MI-LCDR
Additional board for long distance installations of the
display. Connection throguh 2-wire telephone cable.
Maximum distance is 1 km. One the board itself as
additional display can be installed.
BESIDES THE STANDARD VERSION OF THE LCD – REMOTE – CONTROL A BIG
VARIETY OF FRONT PANELS ARE AVAILABLE. THE FRONT PANELS CAN BE
STYLED INDIVIDUALLY ACCORDING TO CUSTOMER REQUESTS.
The philosophy, inder which Micronova developed this range, is to give the user for low
cost (only a change of the Polycarbonate surface) a maximum of graphical freedom.
The display therefore can be intergrated visually perfect in the finished product of the
customer. Because of the large variety of displays with different LED, digit-indicators,
push-buttons and different dimensions there is an even larger product differentiation
possible. This can and will be all supported by a customer specific Software Development,
accordingly guaranteeing exclusive functions and optics.
REMOTE – CONTROL MODULAR – SYSTEM
MICRONOVA offers a large range of LCD-Displays, that are compatible with different boards
and Microprocessors.
ADVANTAGES OF THE LCD-DISPLAY
The advantages are the possibilities to communicate directly with the user and thereby
reduce or eliminate user faults.
D-LCD 2000
33
HEATING ELEMENT
HEATING ELEMENTS
STAINLESS STEEL TUBULAR HEATING ELEMENTSTYPICAL APPLICATIONS Defrosting evaporators for commercial
and industrial refrigerators, incubators for poultry industry,
industrial applications, ironing presses, counter heating, hotplates...
INFORMATION• Tubes in Stainless Steel Aisi 304 or Aisi 321 or Incoloy 800,
diameter 8.5mm and diameter 6.5mm.
• Silicone double insulated cable.
• Waterproof end moulding with silicone.
• Silicone vulcanizated tapered ends with diam. as per Aisi tube.
• Maximum Asis tube length over 5mt.
• Earth connection with welded-on screw M4x10 or welded-on
male faston 6.3x0.8.
• Element bending, voltage and power as per customer drawing.
• Maximum sheath temperature: 550ºC.
• VDE approval for items up to 3W/cm²
• Test according to IEC EN60335-1 and CENELEC
HD289 S1 standards.
HEATING ELEMENTS
ADR 230
TYPICAL CONSTRUCTION
DIAGRAM TEMPERATURE
ON FREE AIR
ON DISSIPATOR
34
THERMOMETERS
METERS
The CFM-01 is a valuable tool in the measurement of Air Flow and Air Temperature and will
automatically calculate CFM's & CMM (cubic ft. per minute and cubic meters per minute).
Instant/Average and 2/3V max Flow Measurements are simply and easily obtained using the
12key pads to enter the duct or hood area in feet or be measred in m/s, ft/min, knots, km/hr.
and mph. Temperature readings are obtained with a fast response type K thermocouple.
• CFM made easy • Large LCD Dual Display
• ºF / ºC • Auto Off – 9V Battery and Carrying Case included
SPECIFICATIONSDISPLAY 1/2" & 3/8" digits.
BEARING Sapphire Jewel Bearing.
OPERATING TEMPERATURE
Meter 32ºF - 122ºF (0ºC - 50ºC), Vane 32ºF-140ºF (0ºC - 60ºC)
OPERATING HUMIDITY
Less than 80% RH
RANGE OF WIND TEMPERATURE RANGE OF WIND VELOCITY
UNITS RANGE RESOLUTION ACCURACY UNITS RANGE RESOLUTION ACCURACY
ºC 0.0 – 45.0 0.2 ±1.0ºC m/s 0.0 – 45.0 0.1 ±3% ± 0.1
ºF 32.0 – 113.0 0.36 ±1.8ºF ft/min 0.0 – 8800 0.1/1 ±3% ± 10
knots 0.0 – 88.0 0.1 ±3% ± 0.1
Km/hr 0.0 – 140.0 0.1 ±3% ± 0.1
mph 0.0 – 100.0 0.1 ±3% ± 0.1
CFM-01
CAT NO. DESCRIPTION IDN
CFM-01 Thermo-Anemometer 61405
These instruments are the leader in Solar Powered technology
as we now offer ten different versions of our Digital thermometers.
Available in super low light versions 56SD, 72SD, 25SD (8 Lux) and
low light (18 Lux) Series 20SD. These "self powered" thermometers
operate without any batteries and offer an attractive and modern
update to existing refrigeration equipment. Each thermometer has
adjustable calibration, a ten second update time and wide ambient
temperature specifications for both indoor and outdoor installations.
Where customers prefer LED, We offer our 2" retrofit unit, the 20DT.
Now with 110V direct power (No transformer needed) and 1/2" high
intensity red readout. All the digital thermometers are NSF listed.
(1) Equivalent "C available, consult Factory
(2) Features "F/"C switch.
(3) Longer line lengths available
(4) Offered in black or white case.
SERIES SD-LCD
CAT. NO. CASE RANGE (1) SENSOR LENGTH (3) IDN
20SD-BS Back Flange 40/0/160°F 05ft 60110
20SD-HL Hanging 40/0/160°F 05ft 60160
20SD-FS Front Flange 40/0/160°F 05ft 60100
25SD-160Horiz. Wall
Mount (4)40/0/160°F 05ft 60170
56SD-230 Front Flange 40/0/230°F (2) 05ft 60120
72SD-F-160 Front Flange 40/0/160°F 05ft 60140
72SD-U-160 U-Clamp 40/0/160°F 05ft 60150
SERIES DT-LCD
CAT. NO. CASE RANGE SENSOR LENGTH IDN
20DT-F Front Flange 40/0/230°F 05ft 60520
20DT-U U-Clamp 40/0/230°F 05ft 60530
ECONOMY BATTERY TYPE PANEL METER
CAT. NO. CASE RANGE SENSOR LENGTH IDN
LCD58 Panel Mount with Clips 40/0/230°F 04ft 60205
DIGITAL THERMO – ANEMOMETER
56SD-230, 72SD-F, 25SD-160 20DT-F, 20SD-F, 20SD-HL
REMOTE READING DIGITAL THERMOMETERS
LC58
35
DIGITAL THERMOMETER
METERS
# 305• -58/1300ºC and -58/2000ºF Selectable.
• Reading Hold and Maximum Record Function. K–Type
• Thermocouple Input
• 0.1ºC/0.1ºF Resolution
• Single Input and Supply with 1 Pcs 4 Feet Probe
# 307• -58/1300ºC and -58/2000ºF Selectable.
• Reading Hold and Maximum Record Function. K–Type
• Thermocouple Input
• 0.1ºC/0.1ºF Resolution
• Dual Input with Differential Temperature
• (T1 – T2) and Supply. With 2 Pcs 4 Feet Probe
TPK-01 BEAD PROBEMeasures surface or Air Temperature to 200ºC (392ºF) 4Ft. long wire
has an Industry Standard Miniature Connector Plug.
TPK-03 IMMERSION PROBEGeneral Purpose Needle Type with Stainless Sheath use for
measurements up to 800ºC (1472ºF).
TPK-04 SURFACE PROBEMiniature, Fast Response Probe, with 800ºC (1472ºF) Max. Surface
Temperature. Ideal for measuring the Surface Temperature of small
electronic parts.
# 400L• CE Approval
• ºF / ºC Selectable
• Built-in Laser Pointer to Improve Aim
• Narrow Field of View (At 12º Distance Measure 1º Target)
• Resolution 0.1ºF / 0.1ºC
• Dimensions 175 x 39 x 72 mm, Weight: 179 Grams
• Fixed Emissivity 0.95
• Distance Spot = 12.1
• Temp. Range -60~500ºC (-76~932ºF)
• Operating Range 0~50ºC (32 ~ 122ºF)
• Accuracy +/-1.0ºC (+/-1.8ºF)
• Auto-Hold and Power-Off Function
• Back Light
• Battery Life Typical 18 Hours Continuous Use
RT-905A• CE Approval
• -50/200ºC & -58/392ºF Switchable
• Max/Min Temperature Memory
• Data Hold Function
• High/Low Temperature Alarm Setting
• Key Tone for Operation Confirmation
• Foldaway Stand
• Stainless Steel Probe 3.5mm x 125mm
with 1m Long Wire
APPLICATIONS
Food Processing, Laboratory Pharmaceutical,
Agriculture, Other Purposes.
HAND HELD THERMOMETER TYPE K THERMOCOUPLE PROBES
NON-CONACT LASER INFRARED THERMOMETER HAND HELD DIGITAL THERMOMETER
DIGITAL THERMOMETER
TPK-04
TPK-03
TPK-01
36
METERS
THERMOMETERS
Accurate Humidity measurement at reasonable cost with usable functions is what best describes the RHT-1
Series. This rugged hand held instrument features a wide humidity measurement range from 10% to 95%
and a temperature range from -4ºF to 140ºF (-20 to 60ºC). Accuracy of 2% RH and 1ºF plus an ºF/C switch,
Hold feature and Output Jack make the RHT-1 ideal for HVAC and Refrigeration applications. The precision
capacitance humidity sensor offers fast response and the output jack offers the ability to record data or
remotely monitor both temperature and humidity. These features are normally found on instruments costing
much more than the reasonably priced RHT-1, complete with 400 hour 9V battery and case.
CAT NO. DESCRIPTION IDN
RHT10% – 95% RH
4/0/140°F61300
HT2096
GENERAL DETAILS
WEIGHTS 200gm (7oz.)
DIMENSIONS 10.6"L x 2.7"W x 1.0"H (270 x 68 x 25mm)
BATTERY Standard 9V (NEDA 1604, 6F22 or 006P)
BATTERY LIFE Approx. 400 Hours
LOW BATTERY INDICATION "BT" indicates on the display
SERIES HT2096
CAT. NO. RANGE IDN
HT2096F 40/0/122°F 39170
HT2096C40/0/70°C
15% – 95% RH39175
DIGITAL TEMPERATURE HUMIDITY TESTER
REMOTE READING DIGITAL THERMOMETERS
RHT – 1
SPECIFICATIONS
ELECTRICAL
DISPLAY 3-1/2 Digits, 1/2" LCD Display
RANGEHumidity 10% – 95 % RH
Temperature: -20 –140ºF, -30 – 60ºC
RESOLUTION 0.1%RH, 0.1ºF, 0.1ºC
ACCURACY
Humidity: 2% RH at 25ºC, 30 – 95% RH
5% RH at 25ºC, 10 – 30% RH
Temperature: ± 1.0ºF, ±0.8ºC
SENSOR TYPEHumidity: Precision Gold Capacitance Sensor
Temperature: Semiconductor Sensor
RESPONSE TIME
Humidity: 45% – 95%, 3 minutes
95% – 45%, 5 minutes
Temperature: 1ºC /2 seconds
SAMPLING RATE 2.5 times per second
AUIXILIARY OUTPUTSHumidity: 10mVdc / 1% RH
Temperature: 10mVdc / 1ºC
ENVIRONMENTAL
OPERATING TEMPERATURE & HUMIDITY32ºF – 122ºF (0ºC – 50ºC) . 85% RH
*(-20 to 140ºF will operate for limited time period)
STORAGE TEMPERATURE & HUMIDITY -10 to 60ºC, 14 to 140ºF . 70% RH
• Temperature, Humidity Indicator
• Desktop or Walll Mounted
• Compact Design
37
OVERAL DIMENSIONS
ROUND THERMOMETER
METERS
DETAILS
Round Thermometer, DIN Scale, Liquid sensing Bulb,
Suitable for boilers, refrigerators, catering equiptments
and household appliances.
ALL MODELS ARE SUPPLIED WITH THREADED TIE-ROD
UPON REQUEST WE CAN SUPPLY
• Dial, numbers and body in different colours
• Temperature scale customer designed
• Different capillary lengths available
• Bulb wit other dimensions
• Quick coupling customer designed
• Head compensation against ambient temperature fluctuations
TECHNICAL DATA
MAX. WITHSTANDING BODY TEMPERATURE 80ºC
BULB BRASS OR COPPER ø 6.5 mm
COPPER CAPILLARY LENGTH 1000 mm
MIN. CAPILLARY BENDING RADIUS 5 mm
MEASURING SYSTEM: BOURDON RADIUS
BLACK PLASTIC HOUSING
PLAIN BLACK FRAME
FASTENING BY SELF-LOCKING GILLS
STANDAR TYPES
MODEL 010259
RANGE 0 / 120ºC
BLACK DIAL / WHITE INSCRIPTIONS
CALIBRATED AT 30ºC ± 2ºK
MODEL 10548
RANGE 0 / 200ºC
BLACK DIAL / WHITE INSCRIPTIONS
CALIBRATED AT 80ºC ± 5ºK
MODEL 10836
RANGE 50ºC /120ºC
BLACK DIAL / WHITE INSCRIPTIONS
CALIBRATED AT 80ºC ± 5ºK
MODEL 010473
RANGE -40ºC / +40ºC
BLACK DIAL / WHITE INSCRIPTIONS
CALIBRATED AT -20ºC ± 2ºK
T. MAX CAPILLARY PVC COVERED 80ºC
MODEL 902
38
RECTANGULAR THERMOMETER
METERS
DETAILS
Rectangular thermometer, Drum Dial, Liquid sensing bulb, suitable
for refrigerators and high temperature appliances.
ALL MODELS ARE SUPPLIED WITH THREADED TIE-ROD
UPON REQUEST WE CAN SUPPLY
• Dial, numbers and body in different colours
• Temperature scale customer designed
• Different capillary lengths available
• Capillary PVC Covered
• Bulb wit other dimensions
• Head compensation against ambient temperature fluctuations
TECHNICAL DATA
MAX. WITHSTANDING BODY TEMPERATURE 70ºC
BULB BRASS OR COPPER ø 6.5 mm
COPPER CAPILLARY LENGTH 1000 mm
MIN. CAPILLARY BENDING RADIUS 5 mm
MEASURING SYSTEM: BOURDON RADIUS
BLACK PLASTIC HOUSING
PLAIN BLACK FRAME
FASTENING BY SELF-LOCKING GILLS
STANDAR TYPES
MODEL 20656
RANGE 0 / 200ºC
BLACK DIAL / WHITE INSCRIPTIONS
CALIBRATED AT 80ºC ± 5ºK
MODEL 20944
RANGE 50 / 350ºC
BLACK DIAL / WHITE INSCRIPTIONS
CALIBRATED AT 80ºC ± 5ºK
MODEL 02038
RANGE -40ºC / +40ºC
BLACK DIAL / WHITE INSCRIPTIONS
CALIBRATED AT -20ºC ± 2ºK
T. MAX CAPILLARY PVC COVERED 80ºC
MODEL 922
OVERALL DIMENSIONS
39
METERS
DETAILS
• Digital wall mountable / desktop type warning carbon dioxide level
• Alarm Output Drives Relay to control ventilations system
• Super Large LCD display Air Temp & RH or Dew Point, Wet Bulb CO² Values
• NDIR (Non-Dispersive Infared) Waveguide Technology W/ABC
(Automactic Background Calibaration) Preset On
• Display TWA (Time-weight average) 8 hrs value or 15 min STEL
(Short-term exposure limit) Value
• Long Time Drift Compensation
• Visible / Audible Alarm setting
• Monitoring residential, commercial and light-industrial spaces
• Max. / Min. / Average recall function RS232 output every 2sec
for further anaylsis
• OEM Datalogging function is available temperature unit is switchable.
CO2 WALL MOUNT METERS
WALL MOUNT CARBON DIOXIDE MONITOR 7722 / 77232
SPECIFICATIONS
MEASURING RANGECO², 0~9999ppm
2001~9999ppm (out of scale range)
RESOLUTION 1ppm, 0.1ºC, 0.1ºF,0.1% RH
ACCURACY
• ±50ppm ±5% of reading
(CO²), (0~2000ppm)
• Other range are not specified.
±0.6ºC/ ±0.9ºF, ±3% RH
(at 25ºC, 10~90%)
• Others ±5% for other RH ranges.
RH RANGE 0.0%~99.9%
WARM-UP TIME 30 Seconds
RESPONSE TIME CO²: About 30 seconds
CURRENT CONDITIONS<50mA average
<310mA peak current (-55ms)
OPERATING CONDITIONS 0~50ºC, 0~95% RH (avoid condensation) for CO²
STORAGE CONDITIONS -20~60ºC, 0~99% RH (avoid condensation)
POWER SUPPLY 12VDC Adaptor
METER SIZE 130 x 85 x 60 mm (LxWxT)
STANDARD PACKING INCLUDES Meter, Manual, 100–240VAC, white paper box
OPTIONAL ACCESSORY
RS232 software and cabie,
Salt bottles HR33,
HR75 for callibration purpose.
77232: LOW DRIFT AND HIGH PERFORMANCE
CARBON DIOXIDE MEASUREMENT
RH0~99.9%, others are the same
as 7722
CO² MEASURING
RANGE
0~9999ppm
5001~9999ppm (out of scale range)
ACCURACY
±30ppm ±5% of reading
(0~5000ppm)
Other range accuracy
are not specified
OPERATION
CONDITIONS
0~50ºC, 0~95% RH
(avoid condensation) for CO²
40
METERS
CO2 HAND HELD METERS
DETAILS
• Low Drift Portable Meter checking poor indoor air quality in office
• Dual Display 2 Parameters simultaneously: CO², Temperature
• Big LCD Display with High Resolution
• Design with NDIR (Non-Dispersive Infared) Waveguide Technology High
Performance Low Drift Sensor
• Manual Calibration is recommended
• Warning Carbon Dioxide Level
• Backlight function for working in dark area
• Long time drift compensation
• Audible Alarm Threshold setting
• Max. / Min. / Average functions included
• RS232 output every 2 seconds via software to link to PC for further analysis
• Hold function freezes current readings
• Display TWA (Time-weight average) 8 Hrs value or 15 min STEL
(Short-term exposure limit) Value
• Housing designed surrounds with rails to help air ventilation for
quick and accurate readings
• Easy to calibrate at fresh air around 380~420ppm
HANDY CARBON DIOXIDE / TEMP. HIGH PERFORMANCE 77532
SPECIFICATIONS
MEASURING RANGECO², 0~9999ppm
5001~9999ppm (out of scale range)
Temperature: -10~60ºC, (14~140ºF)
RESOLUTION1ppm, -CO² concentration, 0.1ºC / ºF
Temperature
ACCURACY
• ±30ppm ±5% of reading
(CO²), (0~5000ppm)
• Other range are not specified.
• Temperature: ±0.6% ±0.9ºF
SENSING TECH -NDIR Sensor
WARM-UP TIME 30 Seconds
RESPONSE TIMECO²: About 30 seconds (Once environment changed; for
HI to LO or LO to HI temperature)
ALARM SOUND LEVEL Around 80dB
OPERATING CONDITIONS 0~50ºC, 0~95% RH (avoid condensation)
STORAGE CONDITIONS -20~60ºC, 0~99% RH (avoid condensation)
POWER SUPPLY AA Type (UM-3) x 4pcs
BATTERY LIFE >24hours (Alkaline battery)
STANDARD PACKING INCLUDES Meter, Manual, Batteries and Hard Carrying Case
OPTIONAL ACCESSORY RS232 software and D-Sub Connector VZRRS232M
41
METERS
REFRIGERANT GAUGES
RG-80-4L RG-80-4H
DIAL SIZE 3.15" 3.15"
CONNECTION 1/8 NPT 1/8 NPT
TEMPERATURE °C °C
PRESSURE SCALE 250PSI & 17BAR 500PSI & 35BAR
COLOUR BLUE RED
RG-80-410L RG-80-410H
DIAL SIZE 3.15" 3.15"
CONNECTION 1/8 NPT 1/8 NPT
TEMPERATURE ºF & ºC DUAL ºF & ºC DUAL
PRESSURE SCALE 500PSI & 35BAR 800PSI & 55BAR
COLOUR BLUE RED
LRG-250 LRG-500
DIAL SIZE 2 – 1/2" 2 –1/2"
CONNECTION 1/8 NPT 1/8 NPT
TEMPERATURE °C °C
PRESSURE SCALE 250PSI & 17.5kg/cm² 250PSI & 35kg/cm²
REMARK Stainless Steel Case, Glycerine Filled Scale For R22/R134a/
R404A or R134a/R404A/R407C, Also Available
FRG-250 FRG-500
DIAL SIZE 2 – 1/2" 2 –1/2"
CONNECTION 1/4 SAE 1/4 SAE
TEMPERATURE °C °C
PRESSURE SCALE 210PSI & 15kg/cm² 500PSI & 35kg/cm²
REMARK Black Oxide Flange, A Type: 92mm O.D. of Flange,
B Type: 85mm O.D. of Flange, C Type: 80mm O.D. of Flange,
LFRG-250 LFRG-500
DIAL SIZE 2 –1/2" 2 –1/2"
CONNECTION 1/4 SAE 1/4 SAE
TEMPERATURE °C °C
PRESSURE SCALE 250PSI & 17.5kg/cm² 500PSI & 35kg/cm²
REMARK Stainless Steel Case, Glycerine Filled Scale For R22/R134a/
R404A or R134a/R404A/R407C, Also Available
SCALE: R22, R134A, R404A & R407C
SCALE: R410A SINGLE
SCALE: R12, R22 & R502
SCALE: R22, R134A
SCALE: R12 R2 & R502
REFERENCE IPSI = 0.07kg / cm² = 0.067 BAR = 0.0069 MPA = 6.9kpa
42
3-PHASE MONITOR
PHASE MONITORS
FEATURES
• Low cost, single side 3-phase protection
• Bright LED indications for faults and loads energized
• Easy to install, no adjustments
• Wide operating range: 190-600VAC
• Less than 1 second phase loss response
• Automatic reset from a fault condition
• Compact packaging: fits almost anywhere
• Rugged, epoxy-encapsulation for extreme conditions
• Works great with the ICM450 for load side monitoring
of part winding start and mutiple compressor systems.
SPECIFICATIONS
INPUT/OUTPUT
LINE VOLTAGE 190 – 600VAC
FREQUENCY 50/60 Hz
CONTROL VOLTAGE
• ICM401: 18 – 30VAC
• ICM402: 115 – 230VAC
OUTPUT
• RELAY SPST
• ICM401: N.O. 10 amps
• ICM402: N.O. 30 amps
CASE DIMENSIONS 3"1 x 3.2"w x 1.4"h
MODEL: ICM401
ICM401 WIRING DIAGRAM
ICM401 – MODEL
The ICM401 is low cost 3-phase line monitor that protects against
phase loss, phase reversal and phase unbalance, ideally suited to
protect scroll & screw compressors from reverse rotation.
MODE OF OPERATIONIf all 3 phases are relatively equal and in proper sequence,
the normally open contacts (Y/Y-OUT) will close when 24 volts
is applied between C and Y. If the phases are out of sequence
or one is missing, the contacts will never close.
If a phase is lost while the ICM401 is energized, the contacts will
open immediately, and remain open until the error is corrected.
An illuminated green LED indicates that the output is energized,
and illuminated red LED indicates that there is a fault and the
output is de-energized.
43
3~
R
S
T
4
1
3
211
10
9
5
8
67
POWER MONITOR RELAY
PHASE MONITORS
MOTOR
3~
Coil
R(L1)
S(L2)
T(L3)
4
1
3
2
5
8
6
7
Phase R
Phase S
Phase T
Output (1-4)
Output (1-3)
S
R
T
R
T
S
R
S
T
AC POWER
(1-3)
(1-4)
OVER
UNDER
VOLTAGE MONITOR: JVM-1/JVM-2/JVM-3 /JVM-4
This device for monitoring that the 3 phase power supply all phase
voltage are present and phase sequence is correct.
RATED VOLTAGE 3Φ 220V, 380V, 400V, 415V
OUTPUT CAPACITY 5A
JVM-1, JVM-3
Output relay will be switched to ON (#1 & 3 close)
immediately when power is applied to the unit and detecting
that 3 phase sequence correctly. Otherwise keep it at original
position (#1 & 4 close).
In case of any phase failure or drops below 70% of rated
voltage for 3 seconds the output relay will return to original
position to cut power when it is on normally operation.
JVM-2, JVM-4
(1) Phase sequence monitor
(2) Adjustable setting from ±5% to ±20% of rated voltage,
if the line voltage over or under than setting voltage output
relay keep at original position.
Output relay will be switched to ON (#1.3 connected) when
power is applied to unit and detecting that 3 phases are in
correct sequence and the voltage are in the setting range.
TYPEPHASE
FAILURE
PHASE
SEQUENCEUNDER VOLT OVER VOLT
JVM-1 ∕ ∕
JVM-2 ∕ ∕ ∕
JVM-3 ∕ ∕
JVM-4 ∕ ∕ ∕
JVM-3/JVM-4
JVM-3/JVM-4 OPERATION CHART
JVM-1/JVM-2
JVM-1/JVM-3 OPERATION CHART
MODEL: DIAGRAMS
JVM-1 JVM-2 JVM-3 JVM-4
44
INDICATOR LIGHTS
PILOT LAMPS
NPL22 - G A 1 2 3
1. SERIES
NPL22 Normal (Round Head)
NLD22 Simple (Flush Head)
2. CAP COLOUR
R G W Y S
RED GREEN WHITE YELLOW BLUE
3. VOLTAGE RATING
NPL22A E I
AC.DC.24V AC.DC.100-120V AC.DC.220-240V
NLD22A D E G I M
AC.DC.24V DC.110V AC.100-120V DC.220V AC.220-240V AC.380-440V
MODEL DESIGNATION
NPL22-GA
NPL22-R NLD22-R
NPL22-Y NLD22-Y
NPL22-G NLD22-G
45
INDICATOR LIGHTS
NEON INDICATOR LIGHTS
COLOUR Red, Orange, Green. COLOUR Red, Orange, Green.
COLOUR Red, Orange, Green. COLOUR Red, Orange, Green.
COLOUR Red, Orange, Green. COLOUR Red, Orange, Green.
COLOUR Red, Orange, Green. COLOUR Red, Orange, Green.
COLOUR Red, Orange, Green. COLOUR Red, Orange, Green.
N-013 NEON INDICATOR W/RESISTOR 120V 220V
N-014 NEON INDICATOR W/RESISTOR 120V 220V
N-015 NEON INDICATOR W/RESISTOR 120V 220V
N-016 NEON INDICATOR W/RESISTOR 120V 220V
N-017 NEON INDICATOR W/RESISTOR 120V 220V
N-018 NEON INDICATOR W/RESISTOR 120V 220V
N-019 NEON INDICATOR W/RESISTOR 120V 220V
N-020 NEON INDICATOR W/RESISTOR 120V 220V
N-021 NEON INDICATOR W/RESISTOR 120V 220V
N-022 NEON INDICATOR W/RESISTOR 120V 220V
N-023 NEON INDICATOR W/RESISTOR 120V 220V
N-024 NEON INDICATOR W/RESISTOR 120V 220V
N-022P PILOT INDICATOR LIGHT 6V 12V 24V
(WITH WIRE)
(WITH WIRE)N-018P PILOT INDICATOR LIGHT 6V 12V 24V
COLOUR Red, Orange, Green. COLOUR Red, Orange, Green.
46
INDICATOR LIGHTS
INDICATOR LIGHTS
N-701P PILOT INIDCATOR LIGHT 6V 12V 24V
N-701L LED INDICATOR LIGHT W/RESISTOR 6V 12V 24V
COLOUR Red, Yellow and Green are Available for Each Part.
L-601 LED INDICATOR LIGHT WO/RESISTOR 2V
L-602 LED INDICATOR LIGHT WO/RESISTOR 2V
L-603 LED INDICATOR LIGHT WO/RESISTOR 2V
L-605 LED INDICATOR LIGHT WO/RESISTOR 2V
L-606 LED INDICATOR LIGHT WO/RESISTOR 2V
L-607 LED INDICATOR LIGHT WO/RESISTOR 2V
L-608 LED INDICATOR LIGHT WO/RESISTOR 2V
L-609 LED INDICATOR LIGHT WO/RESISTOR 2V
L-610 LED INDICATOR LIGHT WO/RESISTOR 2V
L-612 LED INDICATOR LIGHT WO/RESISTOR 2V
L-613 LED INDICATOR LIGHT WO/RESISTOR 2V
N-701 LED INDICATOR LIGHT W/RESISTOR 2V
N-022P PILOT INDICATOR LIGHT 6V 12V 24V
47
INDICATOR LIGHTS
INIDCATOR LIGHTS
N-702 NEON INDICATOR LIGHT WO/RESISTOR
N-703 NEON INDICATOR LIGHT W/RESISTOR 120V 220V
N-704 NEON INDICATOR LIGHT WO/RESISTOR (N/R) 120V 220V
N-705 NEON INDICATOR LIGHT W/RESISTOR 120V 220V
N-706 NEON INDICATOR LIGHT WO/RESISTOR (N/R) 120V 220V
N-707 PILOT INDICATOR LIGHT 6V 12V 24V
N-708L LED INDICATOR LIGHT W/RESISTOR 6V 12V 24V 120V 220V
N-801 NEON INDICATOR LIGHT W/RESISTOR 120V 220V
N-802 NEON INDICATOR LIGHT W/RESISTOR 120V 220V
N-803 NEON INDICATOR LIGHT W/RESISTOR 120V 220V
N-804 NEON INDICATOR LIGHT W/RESISTOR 120V 220V
N-804A NEON INDICATOR LIGHT W/RESISTOR 120V 220V
N-803P PILOT INDICATOR LIGHT 6V 12V 24VN-705L LED INDICATOR LIGHT W/RESISTOR 6V 12V 24V
N-705P PILOT INDICATOR LIGHT 6V 12V 24V
N-804AP PILOT INDICATOR LIGHT 6V 12V 24V
N-802P PILOT INDICATOR LIGHT 6V 12V 24VN-704L LED INDICATOR LIGHT W/RESISTOR 6V 12V 24V
N-704P PILOT INDICATOR LIGHT 6V 12V 24V
N-804P PILOT INDICATOR LIGHT 6V 12V 24VN-706L LED INDICATOR LIGHT W/RESISTOR 6V 12V 24V
N-706P PILOT INDICATOR LIGHT 6V 12V 24V
N-801P PILOT INDICATOR LIGHT 6V 12V 24V
N-702L LED INDICATOR LIGHT W/RESISTOR 6V 12V 24V
N-702P PILOT INDICATOR LIGHT 6V 12V 24V
COLOUR Red, Yellow and Green are Available for Each Part.
N-703L LED INDICATOR LIGHT W/RESISTOR 6V 12V 24V
N-703P PILOT INDICATOR LIGHT 6V 12V 24V
48
INDICATOR LIGHTS
INDICATOR LIGHTS
N-805 NEON INDICATOR LIGHT W/RESISTOR 120V 220V
N-806 NEON INDICATOR LIGHT W/RESISTOR 120V 220V
N-807 NEON INDICATOR LIGHT W/RESISTOR 120V 220V
N-808 NEON INDICATOR LIGHT W/RESISTOR 120V 220V
N-809 NEON INDICATOR LIGHT W/RESISTOR 120V 220V
N-810 NEON INDICATOR LIGHT W/RESISTOR 120V 220V
N-811 NEON INDICATOR LIGHT W/RESISTOR 120V 220V
N-812 NEON INDICATOR LIGHT W/RESISTOR 120V 220V
N-813 NEON INDICATOR LIGHT W/RESISTOR 120V 220V
N-814 NEON INDICATOR LIGHT W/RESISTOR 120V 220V
N-815 NEON INDICATOR LIGHT W/RESISTOR 120V 220V
N-816 NEON INDICATOR LIGHT W/RESISTOR 120V 220V
N-814L LED INDICATOR LIGHT W/RESISTOR 6V 12V 24V
N-814P PILOT INDICATOR LIGHT 6V 12V 24V
N-808P PILOT INDICATOR LIGHT 6V 12V 24V
N-816P PILOT INDICATOR LIGHT 6V 12V 24V
N-816L RED INDICATOR LIGHT W/RESISTOR 6V 12V 24V
N-813P PILOT INDICATOR LIGHT 6V 12V 24VN-807P PILOT INDICATOR LIGHT 6V 12V 24V
N-815L LED INDICATOR LIGHT W/RESISTOR 6V 12V 24V
N-815P PILOT INDICATOR LIGHT 6V 12V 24V
N-809P PILOT INDICATOR LIGHT 6V 12V 24V
N-812P PILOT INDICATOR LIGHT 6V 12V 24V
N-811P PILOT INDICATOR LIGHT 6V 12V 24VN-805P PILOT INDICATOR LIGHT 6V 12V 24V
N-810P PILOT INDICATOR LIGHT 6V 12V 24V
COLOUR Red, Yellow and Green are Available for Each Part.
N-806P PILOT INDICATOR LIGHT 6V 12V 24V
49
INDICATOR LIGHTS
N-827 NEON INDICATOR LIGHT W/RESISTOR (NR)
N-828 NEON INDICATOR LIGHT W/RESISTOR (NR) 120V 220V
N-828B NEON INDICATOR LIGHT W/RESISTOR 120V 220V
N-830 NEON INDICATOR LIGHT W/RESISTOR 120V 220V
N-831 E-10 SCREW BASE INDICATOR LIGHT HOLDER
N-832 E-10 SCREW BASE INDICATOR LIGHT HOLDER
N-833 SIZE: 30M/M, 20M/M
N-835W NEON INDICATOR LIGHT W/RESISTOR 120V 220V
N-3001 NEON INDICATOR LIGHT W/RESISTOR 120V 220V
N-3002 E-10 S-9 6V 12V 24V 120V 220V
R-2001 4P 6P
R-2002A
COLOUR Red, Yellow and Green are Available for Each Part.
E-5 6V 12V 24VN-830P PILOT INDICATOR LIGHT 6V 12V 24V
5-9 BAYONET BASE INDICATOR LIGHT HOLDER
N-827P PILOT INDICATOR LIGHT 6V 12V 24V
N-828L LED INDICATOR LIGHT W/RESISTOR 6V 12V 24V
N-828P PILOT INDICATOR LIGHT 6V 12V 24V
50
SWITCHING POWER SUPPLY – SINGLE OUTPUT
POWER SUPPLIES
MODEL NO. OUTPUT TOL. R & N EFFI.
S-15-5 5V, 0~3.0A ± 2% 50mV 65%
S-15-12 12V, 0~1.3A ± 1% 50mV 68%
S-15-24 24V, 0~0.7A ± 1% 50mV 73%
MODEL NO. OUTPUT TOL. R & N EFFI.
S-35-5 5V, 0~7.0A ± 2% 75mV 70%
S-35-12 12V, 0~3.0A ± 1% 100mV 76%
S-35-15 15V, 0~2.4A ± 1% 100mV 78%
S-35-24 24V, 0~1.5A ± 1% 100mV 78%
• Low Cost, High Reliability
• AC Input Range selectable
by switch
• Protections: Short
Circuit / Over load
• Cooling by free air convection
• 100% full load burn-in test
• 1 Year Warranty
• Universal AC input / Full Range
• Protections: Short Circuit,
Overload, Over Voltage
• Cooling by free air convection
• Approvals: UL/CUL/TUB/CB/Ce
• Fixed switching frequency
at 50Khz
• 100% full load burn-in test
DETAILS
AC INPUT VOLTAGE RANGE 85~132VAC / 170~264VAC selected by sw.
AC INRUSH CURRENT Cold Start, 15A / 115VAC, 30A / 230VAC
DC ADJUSTMENT RANGE ±10% of rated output Voltage
OVERLOAD PROTECTION 105%~150% fold back limiting, auto-recovery
SETUP, RISE, HOLD UP TIME 200ms, 100ms, 20ms at full load & 230VAC
WITHSTAND VOLTAGE I/P-0/P: 1.5KVAC, I/P-FG: 1.5KVAC, 1min.
WORKING TEMP 0~50°C @ 100%, -10°C @ 80%, 60°C @ 60%
SAFETY STANDARDS Design refer to UL 1012 Requirement
EMC STANDARDS Design refer to FCC part 15J
CONNECTION 5P / 9.5mm pitch terminal block
DETAILS
AC INPUT VOLTAGE RANGE 85~264VAC / 120~370VAC
AC INRUSH CURRENT Cold Start, 30A at 115VAC, 60A at 230VAC
DC ADJUSTMENT RANGE ±10% of rated output Voltage
OVERLOAD PROTECTION 105%~150% hiccup mode, auto-recovery
OVER VOLTAGE PROTECTION 115%~135% of rated output voltage
SETUP, RISE, HOLD UP TIME 300ms, 50ms, 80ms at full load & 230VAC
WITHSTAND VOLTAGE I/P-0/P: 3KVAC, I/P-FG: 1.5KVAC, 1min.
WORKING TEMP 0~45°C @ 100%, -10°C @ 80%, 60°C @ 60%
SAFETY STANDARDS UL 1012, UL1950, TUV EN60950 approved
SAFETY STANDARDSEN55022 class B, EN61000-3-2-3
EN61000-4-2, 3, 4, 5, 6, 8, 11, ENV50204
EMC STANDARDS 5P/9.5mm pitch terminal block
CONNECTION 5P / 9.5mm pitch terminal block
DETAILS
AC INPUT VOLTAGE RANGE 85~132VAC / 170~264VAC selected by sw.
AC INRUSH CURRENT Cold Start, 15A / 115VAC, 30A / 230VAC
DC ADJUSTMENT RANGE (FOR 15W) Cold Start, 18A at 115VAC, 36A at 230VAC
DC ADJUSTMENT RANGE (FOR 35W) ±10% of rated output Voltage
OVERLOAD PROTECTION 105%~150% fold back limiting, auto-recovery
SETUP, RISE, HOLD UP TIME 200ms, 100ms, 30ms at full load & 230VAC
WITHSTAND VOLTAGE I/P-0/P: 1.5KVAC, I/P-FG: 1.5KVAC, 1min.
WORKING TEMP 0~50°C @ 100%, -10°C @ 80%, 60°C @ 60%
SAFETY STANDARDS Design refer to UL 1012 Requirement
EMC STANDARDS Design refer to FCC part 15J
CONNECTION 5P / 9.5mm pitch terminal block
MODEL NO. OUTPUT TOL. R & N EFFI.
S-50-5 5V, 0~10A ± 2% 75mV 71%
S-50-12 12V, 0~4.2A ± 1% 100mV 78%
S-50-15 15V, 0~3.4A ± 1% 100mV 78%
S-50-24 24V, 0~2.1A ± 1% 100mV 82%
MODEL NO. OUTPUT TOL. R & N EFFI.
S-60-5 5V, 0~20A ± 2% 120mV 74%
S-60-12 12V, 0~5.0A ± 1% 120mV 77%
S-60-15 15V, 0~4.0A ± 1% 150mV 78%
S-60-24 24V, 0~2.5A ± 1% 150mV 81%
15W
CASE 90599x97x35mm0.31kgs
35W
CASE 903129x98x38mm0.4kgs
50W
CASE 90199x97x35mm0.39kgs
60W
CASE 901159x97x38mm0.55kgs
51
POWER SUPPLIES
DETAILS
AC INPUT VOLTAGE RANGE 85~264VAC / 120~370VAC
AC INRUSH CURRENT (FOR 25W) Cold Start, 15A / 115VAC, 30A / 230VAC
AC INRUSH CURRENT (FOR 40W) Cold Start, 30A at 115VAC, 60A at 230VAC
DC ADJUSTMENT RANGE ±10% of rated output Voltage
OVERLOAD PROTECTION 105%~150% hiccup mode, auto-recovery
OVER VOLTAGE PROTECTION 115%~135% of rated output voltage
SETUP, RISE, HOLD UP TIME 300ms, 50ms, 80ms at full load & 230VAC
SETUP, RISE, HOLD UP TIME (FOR 40W) 300ms, 50ms, 60ms at full load & 230VAC
WITHSTAND VOLTAGE I/P-0/P: 3KVAC, I/P-FG: 1.5KVAC, 1min.
WORKING TEMP 0~50°C @ 100%, -10°C @ 80%, 60°C @ 60%
SAFETY STANDARDS UL 1012, TUV EN60950 approved
EMC STANDARDS EN55022 class B, EN61000-3-2,3,EN6100-4-2,3,4,5
CONNECTION 5P / 9.5mm pitch terminal block
MODEL NO. OUTPUT TOL. R & N EFFI.
S-25-5 5V, 0~5.0A ± 2% 50mV 72%
S-25-12 12V, 0~2.1A ± 1% 100mV 76%
S-25-15 15V, 0~1.7A ± 1% 100mV 77%
S-25-24 24V, 0~1.1A ± 1% 100mV 80%
MODEL NO. OUTPUT TOL. R & N EFFI.
S-100-3 3V, 0~20A ± 2% 50mV 70%
S-100-5 5V, 0~20A ± 2% 100mV 78%
S-100-7.5 7.5V, 0~13.6A ± 1% 100mV 80%
S-100-10 10V, 0~10A ± 1% 100mV 80%
S-100-12 12V, 0~8.5A ± 1% 100mV 81%
S-100-15 15V, 0~6.7A ± 1% 100mV 81%
S-100-18 18V, 0~5.6A ± 1% 100mV 82%
S-100-24 24V, 0~4.5A ± 1% 100mV 84%
S-100-27 27V, 0~3.7A ± 1% 100mV 84%
S-100-48 48V, 0~2.0A ± 1% 100mV 84%
MODEL NO. OUTPUT TOL. R & N EFFI.
S-40-5 5V, 0~8.0A ± 2% 75mV 72%
S-40-12 12V, 0~3.5A ± 1% 100mV 76%
S-40-15 15V, 0~2.8A ± 1% 100mV 76%
S-40-24 24V, 0~1.8A ± 1% 100mV 78%
• Low Cost, High Reliability
for S-100
• UL/TUV/CB/CE for S-100F
• AC input range selectable
by switch
• Protections: Short Circuit/
Overload/ Over Voltage
• Cooling by free air convention
• Fixed switching frequency
at 25KHz for S-100 and
83KHz for S-100-F
DETAILS
AC INPUT VOLTAGE RANGE 85~132VAC / 170~264VAC selected by sw.
AC INRUSH CURRENT Cold Start, 20A / 115VAC, 40A / 230VAC
DC ADJUSTMENT RANGE ±10% of rated output Voltage
OVERLOAD PROTECTION 105%~150% hiccup mode auto-recovery
SETUP, RISE, HOLD UP TIME 200ms, 80ms, 20ms at full load & 230VAC
WITHSTAND VOLTAGE I/P-0/P: 1.5KVAC, I/P-FG: 1.5KVAC, 1min.
WORKING TEMP0~50°C @ 100%, -10°C @ 80%, 60°C @ 60%
(5V & 7.5V: 0~45°C @ 100%, 60°C @ 50% load)
SAFETY & EMC STANDARDS Design refer to UL 1012 & FFC part 15J
CONNECTION 7P / 9.5mm pitch terminal block
DETAILS
AC INPUT VOLTAGE RANGE 88~132VAC / 170~264VAC selected by sw.
AC INRUSH CURRENT Cold Start, 30A / 115VAC, 60A / 230VAC
DC ADJUSTMENT RANGE 10% of rated output Voltage
OVERLOAD PROTECTION 105%~150% hiccup mode auto-recovery
OVER VOLTAGE PROTECTION 1000ms, 30ms, 15ms, at full load and 230VAC
SETUP, RISE, HOLD UP TIME 200ms, 80ms, 20ms at full load & 230VAC
WITHSTAND VOLTAGE I/P-0/P: 3KVAC, I/P-FG: 1.5KVAC, 1min.
WORKING TEMP 0~50°C @ 100%, -10°C @ 80%, 60°C @ 60%
SAFETY & EMC STANDARDSEN55022 class B EN61000-3-2-3
EN61000-4-2, 3, 4, 5, 6, 8, 11, EENV50204
CONNECTION 7P / 9.5mm pitch terminal block
25W
CASE 90599x97x35mm0.39kgs
40W
CASE 903129x98x38mm0.44kgs
100W
CASE 902199x98x38mm0.65kgs
MODEL NO. OUTPUT TOL. R & N EFFI.
S-100-5 5V, 0~20A ± 2% 100mV 76%
S-100-7.5 7.5V, 0~13.5A ± 1% 125mV 78%
S-100-12 12V, 0~8.5A ± 1% 125mV 80%
S-100-15 15V, 0~6.7A ± 1% 125mV 81%
S-100-24 24V, 0~4.5A ± 1% 150mV 83%
S-100-48 48V, 0~2.2A ± 1% 150mV 84%
52
POWER SUPPLIES
SINGLE OUTPUT SWITCHING POWER SUPPLIES
CASE 926A 247 x 127 x 63.5mm
• AC input range selectable by switch
• Protections: Short circuit / Overload / Over voltage / Over temp.
• Built in remote sense function
• High power density 4.9 W/in³
• Forced air cooling by built-in DC fan
• Approvals: UL / CUL
• 100% full load burn-in test
• Low cost, high reliability
• 2 year warranty
CASE 935B 248 x 127 x 63.5mm
• AC input range selectable by switch
• Protections: Short circuit / Overload / Over voltage / Over temp.
• Built in remote sense function
• High power density 4.9 W/in³
• Forced air cooling by built-in DC fan
• Approvals: UL / CUL
• 100% full load burn-in test
• Low cost, high reliability
• 2 year warranty
DETAILS
AC INPUT VOLTAGE
RANGE
90~132VAC / 180~264VAC selectable
by switch
AC INRUSH CURRENT Cold start, 25A at 115VAC, 50A at 230VAC
DC ADJUSTMENT RANGE ±10% rated output voltage
OVERLOAD PROTECTION 105%~125% shut off, AC recycle to re-start
OVER VOLTAGE
PROTECTION 115%~140% rated output voltage
SETUP, RISE, HOLD UP
TIME 1000ms, 50ms, 20ms at full load and 230VAC
WITHSTAND VOLTAGE I / P-O / P:3KVAC, I / P-FG: 1/ 5KVAC, 1minute
WORKING TEMPERATURE -20+40°C@100%, 60°C@60% load
SAFETY STANDARDS UL60950-1 Approved
EMC STANDARDS Design refer to EN55022 class B
CONNECTION3 / P10mm, 6P / 13mm pitch terminal block with
cover
PACKING 2.1kg ; 6pcs / 13.4pg / 1.2CUFT
DETAILS
AC INPUT VOLTAGE
RANGE
90~132VAC / 180~264VAC selectable
by switch
AC INRUSH CURRENT Cold start, 25A at 115VAC, 50A at 230VAC
DC ADJUSTMENT RANGE ±10% rated output voltage
OVERLOAD PROTECTION 105%~125% shut off, AC recycle to re-start
OVER VOLTAGE
PROTECTION 115%~140% rated output voltage
SETUP, RISE, HOLD UP
TIME 1000ms, 50ms, 20ms at full load and 230VAC
WITHSTAND VOLTAGE I / P-O / P:3KVAC, I / P-FG: 1/ 5KVAC, 1minute
WORKING TEMPERATURE -20+40°C@100%, 60°C@60% load
SAFETY STANDARDS UL60950-1 Approved
EMC STANDARDS Design refer to EN55022 class B
CONNECTION3 / P10mm, 6P / 13mm pitch terminal block with
cover
PACKING 2.1kg ; 6pcs / 13.4pg / 1.2CUFT
STOCK NO. MODEL NO. OUTPUT TOL. R & N EFFI.
11421 SE-1000-5 5V, 0~150A ± 1% 150mV 81%
11422 SE-1000-9 9V, 0~100A ± 1% 150mV 84%
11423 SE-1000-12 12V, 0~83.3A ± 1% 150mV 85%
11424 SE-1000-15 15V, 0~66.7A ± 1% 150mV 86%
11425 SE-1000-24 24V, 0~41.7A ± 1% 200mV 88%
11426 SE-1000-48 48V, 0~20.8A ± 1% 200mV 89%
STOCK NO. MODEL NO. OUTPUT TOL. R & N EFFI.
10661 SE-600-5 5V, 0~100A ± 2% 150mV 78%
10662 SE-600-12 12V, 0~50A ± 1% 150mV 83%
10663 SE-600-15 15V, 0~40A ± 1% 150mV 84%
10664 SE-600-24 24V, 0~25A ± 1% 150mV 87%
10665 SE-600-27 27V, 0~22.2A ± 1% 150mV 87%
10666 SE-600-48 48V, 0~12.5A ± 1% 200mV 88%
600W MODEL 1000W MODEL
53
SOLLATEK VOLTAGE STABILISER (SVS)Over and under Voltage Proctection
RATED VOLTAGE
• High Voltage
• Low Voltage
• Spikes / Surges
• Power-back surges
REGULATORS / STABILISERS
VOLTAGE STABILISERS
STANDARD RANGE
STABILISERS (also known as regulators)
stabilise the incoming power supply
providing constant voltage to the equiptment.
Sollatek manufactures two different ranges
of stabilisers. The SVS (Sollatek Voltage
Stabilisers) Range and the AVR (Automatic
Voltage Regulators) Range.
The following table opposite is a brief
comparision between the two ranges.
AVR SVS
CONTROL Microprocessor Microprocessor
SWITCHING Taps / Traics Taps / Relays
SPEED OF CORRECTION 1250V / S 750V / S
INPUT RANGE -30% to + 22% -26% to + 19%
OUTPUT ACCURACY + / -4% + / -6%
AVS FUNCTION
No
Yes. (Dissconnects the mains supply if
the input varies outside pre-set limits
and reconnects automatically.
For a 230V system these are
below 145V or above 290V)
WEIGHT (OF A 2AMP UNIT) About 5Kg About 2Kg
SUITABLE FOR All electrical and electronic equipment.
However if the price doesn't justify it then
use with only sensitive equipment. Like HI-FI,
Video, TV, Lab equipment, etc.
All electrical and electronic equipment.
If wider input and more accurate output
control is desired then use the AVR.
THE SOLLATEK SVS monitors the mains voltage continuously. If the voltage rises or drops,
the SVS will stabilise the output to ensure the voltage reaching your eqipment remains
constant at 230V (+/-6%), within the operating range of the unit. If the input voltage fallas
below 142V or rises above 295V, the SVS will disconnect the output, thereby protecting the
load. Once the mains voltage returns again witnin acceptable limits, the SVS will reconnect
the output following a start up delay. (* All above voltages are for a 220V/230V system.
For other voltages contact your dealer).
PROTECTION
• Microprocessor Controlled Stabiliser • Extremely fast response
• Very wide input voltage range • 10 second start-up delay as standard
• Excellent output voltage stability (+/-6%) • Includes surge and spike suppression
• Incorporates over-voltage & under • Full RFI & noise suppression
voltage disconnect (ER option only)
SINGLE PHASE - UP TO 15 AMPS
MODEL AMPS VA@240V SOCKET AVAILABILITY WEIGHT DIMS
SVS01-22 1 240 UK FR SCH UK5 1.5 193 x 100 x 124
SVS02-22 2 480 UK FR SCH UK5 2.0 193 x 100 x 124
SVS04-22 4 960 UK FR SCH UK5 3.0 193 x 100 x 124
SVS06-22 6 1440 UK FR SCH UK15 4.0 277 x 133 x 161
SVS08-22 8 1920 UK FR SCH UK15 5.0 277 x 133 x 161
SVS12-22 12 2880 UK FR SCH UK15 7.0 277 x 133 x 161
SVS15-22 15 3600 FR SCH UK15 8.0 277 x 133 x 161
STABILISERS
THE SVS PRINCIPLE
54
W5
Type W5
Control
SP Single-Phase Angle Control
SZ Singe-Phase Zero Crossing Control
TP 3-Wire 3-Phase Angle Control
TZ 2-Wire 3-Phase Zero Crossing Control
ZZ 3-Wire 3-Phase Zero Crossing Control
1V – 110VAC (Only for Single-Phase Power Source)4v – 200 ~ 480VAC
Auxiliary PowerSource Code1 – 1φ 110VAC2 – 1φ 220VAC
Normal Rated Current030 – 30A045 – 45A060 – 60A080 – 80A100 – 100A125 – 125A150 – 150A180 – 180A230 – 230A300 – 300A380 – 380A450 – 450A580 – 580A720 – 720A
030 -2 4 J4VTP
0 – 0~5VDC1 – 1~5VDC2 – 2~10VDC3 – 0~10VDC4 – 4~20mA5 – 0~20mAM – Manual Adjustment* – Special
C – Buffering Time 2 Seconds (Zero-Crossing Type Product)J – Adjustable Buffering Time, 1~22 Secs (Phase-Angle Type Product)
– Standard Type (Fixed Resistance load, Inductive Load or LR Light Bulb)TF – Inductive Reactance Type LoadingCL – Limited Current Type (+ Additional Charges)CV – Fixed Voltage Type (+ Additional Charges)
NOTE
W5-Series has no included potentiometer (VR), the VR parts are
option as following part numbers.
1) Part No. Scale/0~100% (Sticker for Scale Range 0~100%)
2) Part No. KB-RN99D (Knob)
3) Part No. VR-RV24YN-20S/B103 (TOCOS Potentiometer 24Ø 10KΩ)
THYRISTOR POWER REGULATOR
SCR POWER CONTROLLERS
W5 – SERIES
W5TP4V030-24J
DESCRIPTION OF THE CONNECTORS
SP · SZ · TZ TP · ZZDESCRIPTION NOTES
CONNECTOR NO. CONNECTOR NO.
F5 Detection of the fuse burn downThe Connection from power to loading mUst be
connected back to the FS Side
• Empty Do Not Connect
M M + 5VDCOnly for this control board, not for other use Positive
Control Signal Input
+ + Positive Control Signal Input The Default Setting is 4 ~ 20mA when
the Sticker is not marked– – Standard Analog Signal Voltage
E3 E3Connected to the VR 3rd pin of the
Outside Potentiometer Adjustable Output 0 ~ 100%, Please eliminate the
shorted Copper Wire between E3 and E2 when using
the Outside Potentiometer with
(2 ~ 10KΩ)
E2 E2Connected to the VR 2nd pin of the
Outside Potentiometer
E1 E1Connected to the VR 1st pin of the
Outside Potentiometer
NC NC Alarm Connector Output (Normal Close) Connector Capacity : 227VAC/2A
125VAC/2A
30VAC/2A
COM COM Alarm Connector Output (Common Point)
NO NO Alarm Connector Output (Normal Open)
AC1 AC1Auxiliary Power Source
Please refer to the stick for the auxiliary
power and voltageAC2 AC2
55
RELAYS
SCL/SCL-1 RELAYS
FEATURES
• Epoxy sealed type and flux free.
• Multiple choice with Lamp, Stud, Diode,
Flashed contact, and Flange cover.
• Contact rating up to 12A/250VAC (DPNO).
• High Reliability/Long life expectancy.
• Socket and PCB terminal available.
ORDERING INFORMATION
CONTACT RATING
LOAD TYPE DPDT DPNO
RESISTIVE LOAD 10A/28VDC 10A/28VDC
MOTOR (UL CSA ONLY) 1/2 HP 250VAC, 1/3 HP 125VAC 1/2 HP 250VAC, 1/3 HP 125VAC
GEN, USE 10A/240VAC 15A/240VAC (UL CSA Only)
SCL
Type SCL Series
Terminal TypeBlank: Socket Terminal1: P C B Terminal
Coil Voltage
Cover TypeBlank: Straight CoverC1: Flange CoverS: Sealed Type
DPDT: Double Pole Doble ThrowDPNT: Double Pole Normally Open
Optional:Blank: Standard TypeL: With Lamp D: With DiodeG: With Stud M: With Manual Button
-1 -L -DPNO -C 220VAC
COIL DATA SCL (DC)
RATED VOLTAGE
(V)
RATED CURRENT
± 10% AT 25°C
(MA)
COIL RESISTANCE
± 10% AT 25°C
(Ω)
MAX.
CONTINUOUS
VOLTAGE AT 25°C
PICK UP VOLTAGE
(MAX) AT 25°C
DROP OUT
VOLTAGE (MIN)
AT 25°C
POWER
CONSUMPTION AT
RATED VOLTAGE
6 150 40
110% Of
Rated Voltage
75% Of
Rated Voltage
10% Of
Rated VoltageApprox. 0.9W
12 75 160
15 60 250
24 37 650
48 19 2600
60 15 4000
110 10 11000
120 11 11000
COIL DATA SCL (AC)
RATED VOLTAGE (V) COIL RESISTANCE
± 10% AT 25°C
(Ω)
MAX. CONTINUOUS
VOLTAGE AT 25°C
PICK UP VOLTAGE
(MAX) AT 25°C
DROP OUT VOLTAGE
(MIN) AT 25°C
POWER
CONSUMPTION AT
RATED VOLTAGE
12 40
110% Of
Rated Voltage
85% Of
Rated Voltage
30% Of
Rated VoltageApprox. 1.2VA
24 160
110 3400
115 3400
120 3400
220 13600
230 13600
240 13600
56
RELAYS
SCLB/SCLD RELAYS
FEATURES
• Miniature size from 2 pole to 4 pole.
• AC & DC Coil.
• Epoxy sealed type and flux free.
• High reliability/Long life expectancy.
• Multiple choice with Lamp, Stud, Diode,
Flashed contact, and Flange cover.
ORDERING INFORMATION
CONTACT RATING
LOAD TYPE SCLB SCLD
RESISTIVE LOAD 5A/28VDC 5A/28VDC
GEN, USE 5A/240VAC 5A/250VAC
SCL
Type SCL Series
Terminal TypeW: Soldered Lug TerminalP: P C B Terminal
Blank: Standard TypeB: Reinforce Barner
B: 2P D:4P
Coil Voltage
Cover TypeC: Straight CoverC1: Flanged CoverS: Seaded Type
Contact FormDPDT: Double Pole Double Throw4PDT: Four Pole Double Throw
Optional:Blank: Standard TypeL: With Lamp D: With DiodeG: With Stud M: With Manual ButtonF: Ag Contact With Au Plating
-P -L -DPDT -C 220VAC-BB
COIL DATA SCL (DC)
RATED VOLTAGE
(V)
RATED CURRENT
± 10% AT 25°C
(MA)
COIL RESISTANCE
± 10% AT 25°C
(Ω)
MAX.
CONTINUOUS
VOLTAGE AT 25°C
PICK UP VOLTAGE
(MAX) AT 25°C
DROP OUT
VOLTAGE (MIN)
AT 25°C
POWER
CONSUMPTION AT
RATED VOLTAGE
6 150 40
110% Of
Rated Voltage
75% Of
Rated Voltage
10% Of
Rated VoltageApprox. 0.9W
12 75 160
15 60 250
24 37 650
48 19 2600
60 15 4000
110 10 11000
120 11 11000
COIL DATA SCL (AC)
RATED VOLTAGE (V) COIL RESISTANCE
± 10% AT 25°C
(Ω)
MAX. CONTINUOUS
VOLTAGE AT 25°C
PICK UP VOLTAGE
(MAX) AT 25°C
DROP OUT VOLTAGE
(MIN) AT 25°C
POWER
CONSUMPTION AT
RATED VOLTAGE
12 40
110% Of
Rated Voltage
85% Of
Rated Voltage
30% Of
Rated VoltageApprox. 1.2VA
24 160
110 3400
120 3400
220 13600
240 13600
57
RELAYS
737 RELAYS
FEATURES
• Multiple enclosure style.
• Indicator Lamp and push-to-test
button option available.
• Plug-in version or PCB terminals.
• High rating 30A 300VAC/28VDC, 15A
600VAC. General Purpose Power relays.
• Available HP ratings 1 HP 120VAC, 1.5 HP
200-600V.
ORDERING INFORMATION
CONTACT RATING
RESISTIVE LOAD 30A/300VAC, 30A/28VDC, 15A/600VAC
MOTOR 1 HP 120VAC, 1.5 HP 200-600VAC
737
Type 737
Contact Form
1X: Single Pole Double Make
1Y: Single Pole Double Break
1Z: Single Pole Double Make/Break
Enclosure StyleBlank: Open TypeC: Plastiv Dust CoverC1: Mounting Ears on CoverC2: Accessible mounting hole with Antirotation TabC3: Mounting Ears on top of Cover
Coil Voltage
OptionalBlank: No Special FeatureL: Provided LampM: Push ButtonT:: PCB Terminal
LMT 12VDC-C1-1X
COIL DATA SCL (AC)
RATED VOLTAGE (V) RATED CURRENT
± 10% AT 25°C
(MA)
COIL RESISTANCE
± 10% AT 25°C
(Ω)
MAX.
CONTINUOUS
VOLTAGE AT 25°C
PICK UP VOLTAGE
(MAX) AT 25°C
DROP OUT VOLTAGE
(MIN) AT 25°C
POWER
CONSUMPTION AT
RATED VOLTAGE
1X
1Y
6 188 32
110% Of
Rated Voltage
80% Of
Rated Voltage
10% Of
Rated VoltageApprox. 1.5W
12 100 120
24 51 472
48 27 1800
110 11 10000
125 12.5 10000
1Z
6 250 24
12 125 96
24 63 384
48 31 1536
110 11.5 9600
125 13 9600
COIL DATA 737 (AC)
Rated Voltage (V) Coil Resistance
± 10% at 25°C (Ω)
Max. Continuous
Voltage at 25°C
Pick Up Voltage (Max)
at 25°C
Drop Out Voltage
(Min) at 25°C
Power Consumption
at rated Voltage
6 4.2
110% Of
Rated Voltage
85% Of
Rated Voltage
30% Of
Rated VoltageApprox. 3.4VA
12 18
24 72
110 1580
120 1700
220 5500
240 7200
58
RELAYS
735 RELAY
FEATURES
• Industry standard octal-type termination
for quick installation.
• Contact arrangements from 1 form A
to 3 form C.
• Indicator lamp and push-to-test button
option available.
• Anti-sticking contact midget.
ORDERING INFORMATION
CONTACT RATING (RATED LOAD)
RESISTIVE LOAD1A, 1B, 1C, 2A, 2B, 2C 3A, 3B, 3C
20A/240VAC, 15A/28VDC 20A/240VAC, 15A/240VAC/28VDC
MOTOR 3/4 HP 120VAC, 1 HP 240VAC 1/2 HP 120VAC/240VAC
735
Type 735
Enclosure StyleBlank: Open TypeC: Plastiv Dust CoverC1: Mounting Ears on CoverC2: Accessible mounting hole with Antirotation TabC3: Mounting Ears on top of Cover
Contact Form1A: SPNO1B: SPNC1C: SPDT2A: DPNO2B: DPNC2C: DPDT3A: TPNO3B: TPNC3C: TPDT
Coil Voltage
OptionalBlank: No Special FeatureL: Provided LampM: Push ButtonT: PCB Terminal
LMT 12VDC-C1-3C
COIL DATA 735 (AC)
RATED VOLTAGE (V) RATED CURRENT
± 10% AT 25°C
(MA)
COIL RESISTANCE
± 10% AT 25°C
(Ω)
MAX.
CONTINUOUS
VOLTAGE AT 25°C
PICK UP VOLTAGE
(MAX) AT 25°C
DROP OUT VOLTAGE
(MIN) AT 25°C
POWER
CONSUMPTION AT
RATED VOLTAGE
SP
DP
6 188 32
110% Of
Rated Voltage
80% Of
Rated Voltage
10% Of
Rated Voltage
Approx. 1.2W
12 100 120
24 51 472
48 27 1800
110 11 10000
125 12.5 10000
TP
6 250 24
Approx. 1.5W
12 125 96
24 63 384
48 31 1536
110 11.5 9600
125 13 9600
CONTACT RATING (RATED CSA APPROVAL RATING)
RESISTIVE LOAD
1A, 1B, 1C 2A, 2B, 2C 3A, 3B, 3C
25A/277VAC/28VDC
10A/600VAC
25A/277VAC/28VDC
10A/600VAC
20A/277VAC
15A/28VDC
MOTOR1.5 HP 240VAC
1 HP 120VAC
1.5 HP 240VAC
1 HP 120VAC
1 HP 240VAC
3/4 HP 120VAC
59
RELAYS
841 RELAY
FEATURES
• Industry Standard Octal-Type Termination
for quick installation.
• Contact arrangements from 1 form A
to 3 form C.
• Indicator lamp and push-to-test botton
option available.
• Anti-sticking contact midget.
ORDERING INFORMATION
COIL DATA (AC)
Rated Voltage (V) Coil Resistance
± 10% at 25°C (Ω)
Max. Continuous
Voltage at 25°C
Pick Up Voltage (Max)
at 25°C
Drop Out Voltage
(Min) at 25°C
Power Consumption
at rated Voltage
6 275
110% Of
Rated Voltage
80% Of
Rated Voltage
10% Of
Rated Voltage
Approx.
1.7VA ~ 2.7VA
12 138
24 74
48/50 39/40
100/120 18.7/22.1
200,240 9.1/10.8
COIL DATA SCL (DC)
RATED VOLTAGE
(V)
RATED CURRENT
± 10% AT 25°C
(MA)
COIL RESISTANCE
± 10% AT 25°C
(Ω)
MAX.
CONTINUOUS
VOLTAGE AT 25°C
PICK UP VOLTAGE
(MAX) AT 25°C
DROP OUT
VOLTAGE (MIN) AT
25°C
POWER
CONSUMPTION AT
RATED VOLTAGE
3 638 4.7
110% Of
Rated Voltage
75% Of
Rated Voltage
10% Of
Rated VoltageApprox. 1.92W
6 319 18.8
12 160 75
24 80 300
48/50 40/411.6 1200
100 19.2 5200
110 17.4 6300
200 9.5 21000
CONTACT RATING
LOAD TYPE 1A (SPDM) 2A (DPDM)
RATED LOAD (RESISTANCE) 30A/22VAC 25A/220VAC
MAX. SWITCHING CURRENT 30A 25A
MAX. SWITCHING VOLTAGE 277VAC 277VAC
MAX. SWITCHING CAPACITY 6600VAC 5500VAC
841
Type 841
Contact Form1A: SPDM Single Polw Double Make2A: DPDM Double POle Double Make
S: Quick TerminalP: P C B Terminal
Coil Voltage
Blank: Standard TypeH: High Insulation Type(Enlarge Contact Spacing)
Cover TypeC: Flux Free TypeD: Dust CoverS: Sealed Type
-1A -C -H 220VAC-S
60
RELAYS
SOCKETS
PTF-08A FIT TO SCL, SCLA-S
PTF-08A FIT TO SCLA-W
PTF-08A FIT TO SCLD-W
61
HC1 RELAYS
RELAYS
HC1 AC Contactor mainly applies to circuit of AC 50Hz (or 60Hz),
rated working voltage up to 400V, rated working current up to 63A
to control household electric applicances and low inductive reactance
load and micro inductive reactance load of similar usage, can also
be used to control household motor load of which controlling power
needs to be relatively decreased.This product applies to places
such as household, hotels, apartments, etc to realize the automation
of large scale produced household electric appliances. Its main
performance indicaes comply with standards of IE1095, etc.
APPLICATIONS
SPECIFICATION
HC1 RELAYS
RATED OPERATING CURRENTS AND POWER RATINGS
AC-1/AC-7A SWITCHING OF HEATERS HC1-20 HC1-23 HC1-40 HC1-63
RATED OPERATION CURRENT LE(NO) 20A 24A 40A 63A
RATED OPERATION CURRENT LE(NC) 20A 24A 30A 30A
RATED OPERATION POWER (NO) 2 current paths connected in parallel permit a 1.6 fold increase in rated operating current le.
230V SINGLE-PHASE 4.0KW 5.3KW 8.8KW 13.8KW
230V 3-PHASE — 9KW 15.2KW 24KW
400V 3-PHASE — 16KW 26KW 41KW
AC-3/AC-7B SWITCHING OF HEATERS HC1-20 HC1-23 HC1-40 HC1-63
RATED OPERATION CURRENT LE(NO) 9A 9A 22A 30A
RATED OPERATION CURRENT LE(NC) 9A 6A — —
RATED OPERATION POWER (NO)
230V SINGLE-PHASE 1.3KW 1.3KW 3.7KW 5KW
230V 3-PHASE — 2.2KW 5.5KW 8KW
400V 3-PHASE — 4KW 11KW 15KW
HC1 RELAYS
62
FEATURES
RELAYS
SOLID STATE RELAYS
SERIES MODEL NO.MAX. LOAD
CURRENTLOAD VOLTAGE
BLOCKING
VOLTAGE
INPUT CONTROL
VOLTAGE
MUST TURN OFF
VOLTAGE
KB20C02A 02A, 03A, 04A, 0A 24 – 280VAC 600VAC PEAK3 – 32VDC 1VDC
KB40C04A 04A, 06A 24 – 480VAC 1200VAC PEAK
10-2-20C02A1 / 2 / 4 / 8 PORTS
02A, 04A24 – 280VAC 600VAC PEAK
3 – 32VDC 1VDC
10-4-40C02A1 / 2 / 4 / 8 PORTS
02A, 04A24 – 480VAC 1200VAC PEAK
KD20C25AX
10A, 25A, 40A,
50A, 75A, 90A,
100A
24 – 280VAC 600VAC PEAK 4 – 32VDC 1VDC
KD40C75AX
10A, 25A, 40A,
50A, 75A, 90A,
100A
48 – 480VAC 1200VAC PEAK 4 – 32VDC 1VDC
KF0602D
KF0604D
2A
4A3 – 60VDC 80VDC 3 – 32VDC 1VDC
10-2-0602D1 / 2 / 4 / 8 PORTS
02A3 – 60VDC 80VDC
3 – 32VDC 1VDC
10-2-0604D1 / 2 / 4 / 8 PORTS
04A3 – 60VDC 80VDC
KG1005D05, 12, 25, 40,
50, 755 – 120VDC 140VDC
3 – 32VDCKG2075D
10, 25, 40, 50, 75 5 – 240VDC 300VDC
KL20C40AX
10A, 25A, 40A,
50A, 75A, 90A,
100A
24 – 280VAC 600VAC PEAK 80 – 280VAC 10VAC
KL40C90AX
10A, 25A, 40A,
50A, 75A, 90A,
100A
48 – 480VAC 1200VAC PEAK 80 – 280VAC 10VAC
KR2025AX 10A, 25A, 40A 24 – 280VAC 600VAC PEAK BR500KΩ PHASE CONTROL
KR4040AX 25A, 40A 48 – 480VAC 1200VAC PEAK VR1MΩANALOG
SWITCHING
3 PHASE – SOLID STATE RELAY
SERIES MODEL NO. LOAD CURRENT LOAD VOLTAGEBLOCKING
VOLTAGE
CONTROL
VOLTAGE
MUST TURN OFF
VOLTAGE
K3PH20C25DA25A, 40A, 50A,
75A, 90A, 100A24 – 280VAC 600VAC 6 – 32VDC 3VDC
K3PH40C75DA25A, 40A, 50A,
75A, 90A, 100A48 – 480VAC 1200VAC 12 – 32VDC 9.5VDC
K3PH20C025AA25A, 40A, 50A,
75A, 90A, 100A24 – 280VAC 600VAC 80 – 280VAC 10VAC
K3PH40C75AA25A, 40A, 50A,
75A, 90A, 100A48 – 480VAC 1200VAC 80 – 280VAC 10VAC
K3PI20C25DA25A, 40A, 50A,
75A, 90A, 100A24 – 280VAC 600VAC 6 – 32VDC 3VDC
K3PI40C40DA25A, 40A, 50A,
75A, 90A, 100A48 – 480VAC 1200VAC 12 – 32VDC 9.5VDC
K3PI20C75AA25A, 40A, 50A,
75A, 90A, 100A24 – 280VAC 600VAC 80 – 280VAC 10VAC
K3PI40C90AA25A, 40A, 50A,
75A, 90A, 100A48 – 480VAC 1200VAC 80 – 280VAC 10VAC
63
RELAYS
SOLID STATE RELAYS & ACCESSORIES
KB-KF SERIES 10-X SERIES
NOTE X= 2PORT/4PORT/8PORT
MODEL NO. DIMENSION
IO-2-20C04A 34 x 85 x 51
IO-4-20C04A 64 x 85 x 51
IO-8-20C04A 124 x 85 x 51
IO-2-20C04D 34 x 85 x 51
IO-4-20C04D 64 x 85 x 51
IO-8-20C04D 124 x 85 x 51
KD-KG-KL-KR SERIES
KD-KG-KL-KR SERIES
KD-KG-KL-KR SERIES
MODEL NO. FOR 1Φ SSR MODEL NO. FOR 1Φ SSR MODEL NO. FOR 1Φ SSR MODEL NO. FOR 1Φ SSR MODEL NO. FOR 1Φ SSR
H060 – 50 10A – 15A H080 – 50 25A H100 – 45 10A H104 – 104 25A – 40A H197 – 100 25A, 40 A
H060 – 80 25 H080 – 100 40A H100 – 70 25A H104 – 104F 40A – 50A
H060 – 100 40A H080 – 150 50A H100 – 100 40A H104 – 120F 50A – 75A
H060 – 120 50A H100 – 120 50A H104 – 150F 75A – 100A
H060 – 150 75A H100 – 150 75, 100A "F" with fan (110V or 220VAC)
H050-50 (FOR 1Φ, 10A)
64
SWITCHES
CURRENT SWITCHES
RIBXK SERIES – CURRENT SENSOR – ENCLOSED SOLID CORE CURRENT SENSORS
RIBXG SERIES – CURRENT SENSOR – ENCLOSED SPLIT CORE CURRENT SENSORS
MODEL NO. RANGE TYPE THRESHOLD OUTPUT LED 1 LED 2
RIBXKF .25 – 150 Amp SOLID CORE FIXED SOLID STATE SWITCH SPST ; 30 VAC/DC ; .4 AMPS MAX (WHT/YEL 16" 18 AWG WIRE LEADS)
RIBXKTF .25 – 150 Amp SOLID CORE FIXED SOLID STATE SWITCH SPST ; 30 VAC/DC ; .4 AMPS MAX (TERMINAL STRIP, ACCEPTS #14-22 AWG WIRE)
RIBXKA .50 – 150 Amp SOLID CORE ADJUSTABLE SOLID STATE SWITCH SPST ; 30 VAC/DC ; .8 AMPS MAX (WHT/YEL 16" 18 AWG WIRE LEADS) OVER TRIP POINT UNDER TRIP POINT
RIBXKTA .50 – 150 Amp SOLID CORE ADJUSTABLE SOLID STATE SWITCH SPST ; 30 VAC/DC ; .8 AMPS MAX (TERMINAL STRIP, ACCEPTS #14-22 AWG WIRE) OVER TRIP POINT UNDER TRIP POINT
MODEL NO. RANGE TYPE THRESHOLD OUTPUT LED 1 LED 2
RIBXGF .35 – 150 AMP SPLIT CORE FIXED SOLID STATE SWITCH SPST ; 30 VAC/DC ; .4 AMPS MAX (WHT/YEL 16" 18 AWG WIRE LEADS)
RIBXGFL .75 – 150 AMP SPLIT CORE FIXED SOLID STATE SWITCH SPST ; 30 VAC/DC ; .4 AMPS MAX (WHT/YEL 16" 18 AWG WIRE LEADS) OVER TRIP POINT
RIBXGTF .35 – 150 AMP SPLIT CORE FIXED SOLID STATE SWITCH SPST ; 30 VAC/DC ; .4 AMPS MAX (TERMINAL STRIP, ACCEPTS #14-22 AWG WIRE)
RIBXGTFL .75 – 150 AMP SPLIT CORE FIXED SOLID STATE SWITCH SPST ; 30 VAC/DC ; .4 AMPS MAX (TERMINAL STRIP, ACCEPTS #14-22 AWG WIRE) OVER TRIP POINT
RIBXGA .75 – 150 AMP SPLIT CORE ADJUSTABLE SOLID STATE SWITCH SPST ; 30 VAC/DC ; .4 AMPS MAX (WHT/YEL 16" 18 AWG WIRE LEADS) OVER TRIP POINT UNDER TRIP POINT
RIBXGTA .75 – 150 AMP SPLIT CORE ADJUSTABLE SOLID STATE SWITCH SPST ; 30 VAC/DC ; .4 AMPS MAX (TERMINAL STRIP, ACCEPTS #14-22 AWG WIRE) OVER TRIP POINT UNDER TRIP POINT
SPECIFICATIONS
SPECIFICATIONS
OPERATING TEMPERATURE -30 to 140°F
MAX SENSE VOLTAGE 600 VAC
APPROVALS UL Listed, UL916, UL864, C-UL, CE
HOUSING RATING Plenum, NEMA 1
MOUNTING/ Removable mounting tab provided.
INSTALLATION The wire clamp locks against the load
wire, securing the unit in place.
RIBXKA
RIBXKTF
OPERATING TEMPERATURE -30 to 140°F
MAX SENSE VOLTAGE 600 VAC
APPROVALS UL Listed, UL916, UL864, C-UL, CE
HOUSING RATING Plenum, NEMA 1
MOUNTING / Removable mounting tab provided
INSTALLATION The wire clamp locks against the load
wire, securing the unit in place.
RIBXGA
RIBXGTF
SENSOR OUTPUTSOLID STATE CONTACT30VAC / DC0.4 AMP MAX. RIBXKF, RIBXKTF0.8 AMP MAX. RIBXKA, RIBXKTAWhen current sensor status is off (open)Leakage <30 uA @ 30VAC/DCWhen current sensor status is on (closed)Voltage Drop <0.3VAC/DC @ 0.1AMP <1.6VAC/DC @ 0.4 AMP
SENSOR OUTPUTSOLID STATE CONTACT30VAC / DC 0.4 AMPWhen current sensor status is off (open)Leakage <30 uA @ 30VAC/DCWhen current sensor status is on (closed)Voltage Drop <0.3VAC/DC @ 0.1AMP <1.6VAC/DC @ 0.4 AMP
65
CURRENT SWITCHES
SWITCHES
RIBXGH SERIES – SWITCHING CURRENT SENSOR – SPLIT CORE 120VAC SWITCHING CURRENT SENSORS
RIBKTV SERIES – CURRENT TRANSDUCER – ENCLOSED SOLID CORE CURRENT TO VOLTAGE TRANSDUCERS
OPERATING TEMPERATURE -30 to 140°F
TEMPERATURE DERATING 1 Amp up to 50°C,
0.5 Amp up to 60°C
MAX SENSE VOLTAGE 600 Vac
APPROVALS UL Listed, UL916, C-UL, CE
HOUSING RATING Plenum, NEMA 1
MOUNTING / Removable mounting tab provided.
INSTALLATION The wire clamp locks against the load
wire, securing the unit in place.
MODEL NO. RANGE TYPE THRESHOLD OUTPUT LED 1 LED 2
RIBXGHF 0.5-150 AMP SPLIT CORE FIXED SOLID STATE SWITCH SPST ; 120 VAC/DC ; 1 AMPS MAX (WHT/BLK 16" 18 AWG WIRE LEADS)
RIBXGHTF 0.5-150 AMP SPLIT CORE FIXED SOLID STATE SWITCH SPST ; 120 VAC/DC ; 1 AMPS MAX (TERMINAL STRIP, ACCEPTS #14-22 AWG WIRE)
RIBXGHA .75-150 AMP SPLIT CORE ADJUSTABLE SOLID STATE SWITCH SPST ; 120 VAC/DC ; 1 AMPS MAX (WHT/BLK 16" 18 AWG WIRE LEADS) OVER TRIP POINT UNDER TRIP POINT
RIBXGHTA .75-150 AMP SPLIT CORE ADJUSTABLE SOLID STATE SWITCH SPST ; 120 VAC/DC ; 1 AMPS MAX (TERMINAL STRIP, ACCEPTS #14-22 AWG WIRE) OVER TRIP POINT UNDER TRIP POINT
MODEL NO. RANGE OUTPUT
RIBXKTV5-10 0 – 10 AMP 0 – 5 VDC (TERMINAL STRIP, ACCEPTS #14-22 AWG WIRE)
RIBXKTV5-20 0 – 20 AMP 0 – 5 VDC (TERMINAL STRIP, ACCEPTS #14-22 AWG WIRE)
RIBXKTV5-50 0 – 50 AMP 0 – 5 VDC (TERMINAL STRIP, ACCEPTS #14-22 AWG WIRE)
RIBXKTV5-100 0 – 100 AMP 0 – 5 VDC (TERMINAL STRIP, ACCEPTS #14-22 AWG WIRE)
OPERATING TEMPERATURE -30 to 140°F
ACCURACY 96.8% Full Scale
LOADING RIBXKTV5-10, 1% Error @ 180 kΩ
RIBXKTV5-20, 1% Error @ 90 kΩ
RIBXKTV5-50, 1% Error @ 40 kΩ
RIBXKTV5-100, 1% Error @ 15 kΩ
MAX SENSE VOLTAGE 600 VAC
APPROVALS UL Listed, UL916, UL864, C-UL, CE
HOUSING RATING Plenum, NEMA 1
SENSOR TYPE Solid core with voltage output
MOUNTING/ Removable mounting tab provided.
INSTALLATION The wire clamp locks against the load
wire, securing the unit in place.
SPECIFICATIONS
SPECIFICATIONS
RIBGHF
RIBXGHTF
SENSOR OUTPUTSOLID STATE CONTACT120VAC, 1AMP MAX.
66
SWITCHES
CURRENT SWITCHES
RIBXK 420 SERIES – CURRENT TRANSDUCER – ENCLOSED 20, 50, AND 100 AMP CURRENT TRANDUCERS WITH LOOP POWERED 4 – 20
RIBXF SERIES – CURRENT SENSOR – ENCLOSED INTERNAL FIXED 0.50-30 AMP CURRENT SENSOR
RIBXA SERIES - CURRENT SENSOR - ENCLOSED INTERNAL ADJUSTABLE 0.50-30 AMP CURRENT SENSOR
MODEL NO. RANGE OUTPUT
RIBXK420-20 0 – 20 AMP LOOP POWERED 4-20 MA TRANSMITTER (PRE-WIRED)
RIBXK420-50 0 – 50 AMP LOOP POWERED 4-20 MA TRANSMITTER (PRE-WIRED)
RIBXK420-100 0 – 100 AMP LOOP POWERED 4-20 MA TRANSMITTER (PRE-WIRED)
SPECIFICATIONS
OPERATING TEMPERATURE -30 to 140°F
MAX SENSE VOLTAGE 600 VAC
APPROVALS UL Listed, UL916, UL864, C-UL, CE
HOUSING RATING Plenum, NEMA 1
MOUNTING/ Removable mounting tab provided.
INSTALLATION The wire clamp locks against the load
wire, securing the unit in place.
PRODUCT SPECIFICATIONSOPERATING TEMPERATURE -30 to 140°F
DIMENSIONS 4.00" x 4.00" x 1.80" with .50" NPT Nipple
WIRE LENGTH 16", 600V Rated
APPROVALS UL Listed, UL916, UL864, C-UL,
California State Fire Marshal, CE
HOUSING RATING Plenum, NEMA 1
SENSOR TYPE Internal, with contact status
SENSOR THRESHOLD Fixed, .5 Amps
SENSOR RANGE .50 – 30 Amps
SENSOR OUTPUT Solid Stare Contact 30 Vac/dc, 0.4 Amp
MAX SENSE VOLTAGE 600 VAC
PRODUCT SPECIFICATIONSOPERATING TEMPERATURE -30 to 140°F
DIMENSIONS 4.00" x 4.00" x 1.80" with .50" NPT Nipple
WIRE LENGTH 16", 600V Rated
APPROVALS UL Listed, UL916, UL864, C-UL,
California State Fire Marshal, CE
HOUSING RATING Plenum, NEMA 1
SENSOR TYPE Internal, with contact status
SENSOR THRESHOLD Adjustable, 0.50 – 30 Amps
SENSOR RANGE .50 – 30 Amps
SENSOR OUTPUT Solid Stare Contact 30 Vac/dc, 0.4 Amp
MAX SENSE VOLTAGE 600 VAC
MAXIMUM OUTPUT LOAD RESISTANCE SUPPLY VOLTAGE
MINIMUM MAXIMUM
800 OHMS 24 VDC 35 VDC
500 OHMS 18 VDC 35 VDC
350 OHMS 15 VDC 35 VDC
250 OHMS 13 VDC 30 VDC
200 OHMS 12 VDC 30 VDC
100 OHMS 10 VDC 28 VDC
50 OHMS 9 VDC 28 VDC
Solid State Contact30VAC/DC 0.4 AMP MAX.
SENSOR FEEDBACKCURRENT SENSOR STATUS
CURRENTSENSORCIRCUITRY
PRP
PRPNOT USED
When Current Sensor status is off (open)Leakage <30 uA @ 30VAC/DCWhen Current Sensor status is on (closed)Voltage Drop <0.3 VAC/DC @ 0.1 AMP <1.6 VAC/DC @ 0.4 AMP
Solid State Contact30VAC/DC 0.4 AMP MAX.
SENSOR FEEDBACKCURRENT SENSOR STATUS
CURRENTSENSORCIRCUITRY
PRP
PRPNOT USED
When Current Sensor status is off (open)Leakage <30 uA @ 30VAC/DCWhen Current Sensor status is on (closed)Voltage Drop <0.3 VAC/DC @ 0.1 AMP <1.6 VAC/DC @ 0.4 AMP
67
ELECTRICAL SWITCHES
SWITCHES
SPECIFICATION
701X SERIES
702X SERIES
1. RATING 20A 250VAC.
2. INSULATION RESISTANCE
DC 500V 200MO or more
3. CONTACT RESISTANCE
DC 2 – 4V 1A 20MO or less
4. WITHSTAND VOLTAGE
AC 1500V or more
SWITCH FUNCTION
MODEL NO. OPERATIONS
7011 ON — OFF SPST
7012 ON — ON SPDT
7013 ON OFF ON SPDT
7014 (ON) OFF SPST
7015 ON — (ON) SPDT
7016 (ON) OFF (ON) SPDT
7017 ON OFF (ON) SPDT
7021 ON — OFF DPST
7022 ON — ON DPDT
7023 ON OFF ON DPDT
7024 (ON) OFF DPST
7025 ON — (ON) DPDT
7026 (ON) OFF (ON) DPDT
7027 ON OFF (ON) DPDT
TERMINAL'S TYPE
A SOLDER TERMINAL
B SREW TERMINAL
C QUICK TERMINAL
KEYWAY
KEYWAY
KEYWAY
68
SWITCHES
ELECTRICAL SWITCHES
ACCESSORIES
W-70A
P-70
K-82A
W-30
C-MTA
P-MT
K-82B
W-30B
FOR 70XX
FOR 70XX
FOR 21XX
FOR 3018, 30193020, 3022
FOR MTXX
FOR MTXX
FOR 1101, 1102, 8105, 8105B
FOR 306X
PITCH'S TYPE
A M12.0XP1.0
B M12.0XP0.75
ENFACE TYPE
A ON – OFF
B ON – ON
C ON – OFF – ON
ENFACE TYPE
A ON – OFF
B ON – ON
C ON – OFF – ON
69
ROCKER SWITCHES
SWITCHES
RH SERIES
SPECIFICATIONS
• 16A 125VAC 1/4HP (UL CSA)
• 16A 250VAC 1/4HP (UL, CSA)
• 20A 125VAC 3/4HP (UL)
• 16(4) 250V~T85 1E4 , 10(2)A 250V~5E4
(VDE, SEMKO, DEMKO, NEMKO, FIMKO, SEV)
• INITIAL CONTACT RESISTANCE 20m Ω max.
• INSULATION RESISTANCE 100m Ω min, at 500VDC
• DIELECTRIC STRENGTH 1,000VAC for 1 minute
• ELECTRIC LIFE 16(4) A 250VAC : 10,000 cycles
10(2) A 250VAC : 50,000 cycles
• TEMPERATURE RANGE -20°C to + 85°C
• Switch for Class II appliances
• BASE Nylon 66, UL rated : 94V-2 min
• ACTUATOR Nylon 66/PC, UL rated 94V-2 min
• SPRING Piano Wire
• CONTACT Silver-Cadmium Alloy
• LAMP Neon, Fluorescent for AC; Tungsten bulb for DC
Illuminated types offer only ON-OFF function
• Scallop-shaped types offer only ON-OFF, ON-ON for
non-illumination,ON-OFF for full illumination (Lens unavailable)
SINGLE POLE ROCKER SWITCHES UP TO 20A 125VAC – ROUND OR SQUARE LEN ILLUMINATED
PANEL CUT-OUT
SNAP-IN MOUNTING
PANEL CUT-OUT ( X = PANEL THICKNESS )
X Y DIM.Z
0.75 TO 1.25MM 30.0+0/-0.1 11.0+0.1/-0
1.25 TO 2MM 30.2+0/-0.1 11.0+0.1/-0
2 TO 3MM 30.5+0/-0.1 11.0+0.1/-0
70
PANEL CUT-OUT
SNAP-IN MOUNTING
ROCKER SWITCHES
SWITCHES
R SERIES
SPECIFICATIONS
DOUBLE POLE ROCKER SWITCHES UP TO 20A 125VAC – ROUND OR SQUARE LEN ILLUMINATED
• 16A 125VAC 1/4HP (UL CSA)
• 16A 250VAC 1/4HP (UL, CSA)
• 20A 125VAC 3/4HP (UL)
• 16(4) 250V~T85 1E4 , 10(2)A 250V~5E4
(VDE, SEMKO, DEMKO, NEMKO, FIMKO, SEV)
• INITIAL CONTACT RESISTANCE 20m Ω max.
• INSULATION RESISTANCE 100m Ω min, at 500VDC
• DIELECTRIC STRENGTH 1,000VAC for 1 minute
• ELECTRIC LIFE 16(4) A 250VAC : 10,000 cycles
10(2) A 250VAC : 50,000 cycles
• TEMPERATURE RANGE -20°C to + 125°C
• Switch for Class II appliances
• BASE Nylon 66, UL rated: 94V-2 min
• ACTUATOR Nylon 66/PC, UL rated 94V-2 min
• SPRING Piano Wire
• CONTACT Silver-Cadmium Alloy
• TERMINALS Silver Plated Copper
• LAMP Neon, Fluorescent for AC; Tungsten bulb for DC
Illuminated types offer only ON-OFF function
• Flat actuator offeres only full-illumination (no Len)
PANEL CUT-OUT ( X = PANEL THICKNESS )
X Y DIM.Z
0.75 TO 1.25MM 30.0+0/-0.1 22.0+0.15/-0
1.25 TO 2MM 30.2+0/-0.1 22.0+0.15/-0
2 TO 3MM 30.5+0/-0.1 22.0+0.15/-0
71
ROCKER SWITCHES
SWITCHES
BR1-12
SPECIFICATIONS
BR1-12-13L
• RATING 12A 125VAC, 12A 250VAC (UL, CSA) 12(4)A 250V~μ
T85(SEMKO, DEMKO, NEMKO, FIMKO)
• CONTACT RESISTANCE 20m Ω (max)
• INSULATION RESISTANCE DC500V 100M Ω (min.)
• DIELECTRIC VOLTAGE-WITHSTAND 1,000VAC for 1 minute
• OPERATION FORCE 700 ± 200gram
• LIFE CYCLE 10,000 cycles
• TEMPERATURE RANGE -20°C to + 85°C
• BASE Nylon 66, UL rated 94V-2 min
• ACTUATOR PC, UL rated 94V-2 min
• TERMINAL Copper and Brass
• SPRING Steel Wire
• CONTACT Silver Copper Alloy
• NEON LAMP Neon, Fluroescent
• SWITCH FUNCTION on-off
ROUND ILLUMINATED MINI-ROCKER SWITCHES UP TO 12A 125VAC – SNAP-IN MOUNTING, CURVE ROUND PANEL
PANEL CUT-OUT
21.00 ± 0.1
2.4
0 ±
0.1
20.0
0 +
0.3
0
–
0.0
0
72
PUSH BUTTON SWITCHES 22Φ / 25Φ
SWITCHES
NPB22-F NLB22-F
NPB22 - F 11 G A 1 2 3 4 5
1. CURRENT RATING (max.)
F Flush Head BMushrom Head
(Protect the ring) 65Φ F Flush Head
E Elevation Head RReset Mushroom
Head 40Φ PFlush Head
(Rubber Cap)
PElevation Head
(Rubber Cap)V
Reset Mushroom Head
(Protect the ring) 65Φ LElevation Head
(Protect the ring)
LElevation Head
(Protect the ring)S
Push-Pull Stop
Mushroom Head 35Φ M Mushroom Head 40Φ
M Mushroom Head 40Φ D Double Push Buttom RReset Mushroom
Head 40Φ
KMushroom Head
(With key) 40Φ D Double Push Button
3. CONTACT BLOCKS
10 1a 21 2a1b
01 1b 12 1a2b
11 1a1b 22 2a2b
20 2a 02 2b
1. SERIES
NPB22 Non-Illuminated
NLB22 Illuminated
5. VOLTAGE RATING
NLB22
A AC.DC.24V
E AC.DC.100-120V
I AC.DC.220-240V
4. CAP COLOUR
NPB22 NLB22
R Red R Red
G Green G Green
Y Yellow Y Yellow
S Blue
B Black
NPB22
MODEL DESIGNATION
73
SWITCHES
PUSH BUTTON SWITCHES 22Φ / 25Φ
SPECIFICATION
NPB22-E
NPB22-P
NPB22-M
NPB22-R
NLB22-F
NLB22-P
NLB22-M
NLB22-R
74
SWITCHES
FLOW SWITCHES
LIQUID FLOW SWITCH
LIQUID FLOW SWITCH
TYPE FF81• Casing in shock-proof thermoplastic
with self-retaining screws
• Threaded brass connection G1 Nylon cable
gland G 3/8
• AISI 301 stainless steel blades from G1 to G4
• Protection class 2
TYPE FF84• Stainless steel case
• Threaded brass connection G1
• Nickel-plated brass cable gland G 3/8
• Protection Class 1
• AISI 301 Stainless Steel Blades from G1 to G10
• Electric connections on Faston 6.3 (provided)
• SPDT Single-pole Switching Microswitch
ELECTRIC SPECIFICATIONSRATED INSULATION VOLTAGE Ui 380V~
CONTINUOUS DUTY RATED CURRENT LTH 10A
RATED OPERATING CURRENT IE 220V~ 250V~
RESISTANCE LOAD AC-12 10A
INDUCTIVE LOAD AC-15 3A
DIRECT CURRENT DC-13 0,2A
• Casing in shock-proof thermoplastic AISI 301
stainless steel blades for pipes from G1" to G8"
• Direct fixing by threaded connection G1"
ELECTRIC SPECIFICATIONSRATED INSULATION VOLTAGE Ui 380V~
CONTINUOUS DUTY RATED CURRENT LTH 10A
RATED OPERATING CURRENT IE: 220V~ 250V~
RESISTANCE LOAD AC-12 16A
INDUCTIVE LOAD AC-15 6A
DIRECT CURRENT DC-13 0.2A
TYPEPIPE
DIAMETER
MINIMUM CALIBRATION VALUE
(dm/sec) WITH FLOW:
MAXIMUM CALIBRATION VALUE
(dm/sec) WITH FLOW:MAXIMUM
OPERATING
PRESSURE
TEMPERATURE
RANGE
MAXIMUM
AMBIENT
TEMPERATURE
PROTECTION
LEVELINCREASING DECREASING INCREASING DECREASING
FF84
FF81
G1 0,26 0,16 0,58 0,53
10 BAR -20 TO 110°C 50°C IP54G2 0,8 0,6 1,7 1,6
G3 1,7 1,2 3,2 3
G4 2,2 1,7 5,1 4,8
G6 4,7 3,4 9 8,5
10 BAR -20 TO 110°C 50°C IP54G8 12,9 10,7 26 25,2
G10 26,5 22 43,5 41
TYPEPIPE
DIAMETER
PADDLE
LENGTH
MINIMUM CALIBRATION VALUE
(dm/sec) WITH FLOW:
MAXIMUM CALIBRATION VALUE
(dm/sec) WITH FLOW: TEMPERATURE
RANGE
PROTECTION
LEVELINCREASING DECREASING INCREASING DECREASING
FF82
G1 35 1 0,5 2 1,9
-20 TO 110°C IP65
G1 1/4 35 1,2 0,7 2,9 2,7
G1 1/2 58 1,6 1 3,9 3,6
G2 58 2,9 2,1 6,1 5,7
G2 1/2 89 4 2,7 7 6,5
G3 89 6,1 4,3 11,4 10,7
G489 14,7 11,3 28,9 27,6
167 7,9 6,1 18,4 17,3
G589 28,3 22,8 55,5 5,3
167 12,8 9,2 26,7 2,5
G689 43 35,8 85 81,6
167 16,8 12,2 32,5 30,5
G889 85 72,4 172,3 165,5
167 46,4 38,5 94 90,7
75
SWITCHES
FLOW SWITCHES
LIQUID FLOW WITH PLASTIC BLADE
FLOW SWITCHES AND PRESSURE SWITCHES
TYPE FF81P• Casing in shock-proof thermoplastic with
self-retaining screws
• Threaded brass connection G1 Nylon cable gland
G 3/8 Non-toxic thermoplastic resin blade from
G4 with references for cut to G1 G2 G3
TYPE FF91P• Casing in shock-proof thermoplastic with
self-retaining screws
• Threaded brass connection G½ Nylon cable gland
G 3/8 Non-toxic thermoplastic resin blade from G2
with references for cut to G½ G1 G1½
ELECTRIC SPECIFICATIONSRATED INSULATION VOLTAGE Ui 380V~
CONTINUOUS DUTY RATED CURRENT lth 10A
RATED OPERATING CURRENT IE: 220V~ 250V~
RESISTANCE LOAD AC-12 10A
INDUCTIVE LOAD AC-15 3A
DIRECT CURRENT DC-13 0,2A
* For controlling drinking water 85°C
maximum recommended
TYPE PIPE DIAMETER
MINIMUM CALIBRATION VALUE
(dm/sec) WITH FLOW:
MAXIMUM CALIBRATION VALUE
(dm/sec) WITH FLOW: TEMPERATURE RANGEMAXIMUM AMBIENT
TEMPERATURE
PROTECTION
LEVELINCREASING DECREASING INCREASING DECREASING
FF81P
G1 0,26 0,16 0,58 0,53
G1 -20 TO 110°C * IP54G2 0,87 0,65 1,65 1,74
G3 1,85 1,3 3,49 3,27
G4 2,39 1,85 5,56 5,23
FF91P
G1/2 0,13 0,8 0,29 0,26
G1/2 -20 TO 110°C * IP54G1 0,26 0,16 0,58 0,53
G1 1/2 0,39 0,24 0,87 0,79
G2 0,8 0,6 1,7 1,6
CODE MODEL DESCRIPTION SIZE PRICE IN €
7.003.00084 SFP 1
Flow Switch - 1.5 l/min operating flow - Male connections -
(2 and 2.5 l/min operating flow
on request) with 1 microswitch
1/2" - 1/2" 43, 60
7.003.00076 SFP 2
Flow Switch - 1.5 l/min operating flow - Male connections -
(2 and 2.5 l/min operating flow
on request) with 2 microswitches
1/2" - 1/2" 46, 20
7.003.00258SFP-RM
M1S
Flow Switch - 1.5 l/min operating flow - Male connections -
(2 and 2.5 l/min operating flow on request) with flow rate
regulator and 1 microswitch
1/2" - 1/2" 52, 10
CODE MODEL DESCRIPTION SIZE PRICE IN €
7.004.00022 SFS 1
Differential pressure switch - operating Δ pressure 50 mbar -
Male connections - (on request can trigger at 25/33/100 mbar)
- (3/8G - 7/16 UNF connections on request)
with 1 microswitch
1/4" 36, 6-
7.004.00049 SFS 2
Differential pressure switch - operating Δ pressure 50 mbar -
Male connections - (on request can trigger at 25/33/100 mbar)
- (3/8G - 7/16 UNF connections on request)
with 2 microswitches
1/4" 39, 90
CODE MODEL DESCRIPTION SIZE PRICE IN €
7.008.00056 SBP 1Differential pressure switch with overpressure valve - triggers at
100 mbar - Male connections - with 1 microswitch3/4" - 1/2" 46, 20
7.008.00043 SBP 2Differential pressure switch with overpressure valve - triggers at
100 mbar - Male connections - with 2 microswitches3/4" - 1/2" 52, 10
76
SWITCHES
LEVEL SWITCHES
RSF16 AND RSF40 DROP FLOAT
MECHANICAL
The drop float has been designed to eliminate problems
associated with limescale build up around the pivot point
of a conventional float switch.
The drop float actuator allows the switch housing and float
pivots to be located above the surface of the liquid and provides
noramlly closed switch contact opening as the liquid level rises.
• Pivot Clear of Liquid
• Compact Design
• Available in Nylon, Polypopylene or PPS.
• Many variants are UL recognised components
FILE No. E171218
• WBS approval.
TECHNICAL SPECIFICATION RSF43 RSF44 RSF46
MATERIAL NYLON POLYPROPYLENEPOLYPHENYLENE
SULPHIDE (PPS)
COLOUR BLACK OPAQUE GREY
TEMP. RANGE °C
°F
-20 / +75
-4 / +167
-20 / +100
-4 / +212
-10 / +120
+14 / +248
MIN. FLUID S.G. 0.75 0.75 0.75
ELECTRICAL SPECIFICATION Y V
CONTACT FORM A25 C3
VA RATING 25 3
BREAKDOWN VOLTAGE DC 800 150
SWITCHING VOLTAGE AC 240 48
SWITCHING VOLTAGE DC 120 28
SWITCHING CURRENT MAX. A 0.6 0.25
77
SWITCHES
LEVEL SWITCHES
RSF40 SERIES
MECHANICAL
This series of floatswitch offers the user a low cost, compact
design with a wide range of options. Available in Acetal, Nylon,
Polypropylene or PPS, most commonly used fluids are catered
for. The compact design makes this device ideal for size sensitive
applications. External mount variants are available in RSF70 or
RSF80 series. A drop Float version is available (see opposite)
for applications where the pivot needs to remain out of the liquid.
• Compact Design
• Available in Nylon, Polypopylene or PPS.
• WBS approval.
• Reliable Reedswitch
• User configurble switching options
• Alternative thread sizes available
• Many variants are UL recognised components FILE No. E171218
ELECTRICAL SPECIFICATION Y V
CONTACT FORM A25 C3
VA RATING 25 3
BREAKDOWN VOLTAGE DC 800 150
SWITCHING VOLTAGE AC 240 48
SWITCHING VOLTAGE DC 120 28
SWITCHING CURRENT MAX. A 0.6 0.25
TECHNICAL SPECIFICATION RSF41 RSF43 RSF44 RSF46
MATERIAL ACETAL NYLON POLYPROPYLENEPOLYPHENYLENE
SULPHIDE (PPS)
COLOUR RED BLACK OPAQUE GREY
TEMP. RANGE °C
°F
-10 / +60
+14 /
+140
-20 / +75
-4 / +167
-20 / +100
-4 / +212
-10 / +120
+14 / +248
MIN. FLUID S.G. 0.875 0.75 0.75 0.75
78
SWITCHES
LEVEL SWITCHES
RSF50 SERIES
MECHANICAL
ELECTRICAL SPECIFICATION Z Y V
CONTACT FORM A10(RSF51/52) A25 C3
VA RATING 10 25 3
BREAKDOWN VOLTAGE DC 215 800 150
SWITCHING VOLTAGE AC 125 240 48
SWITCHING VOLTAGE DC 150 120 28
SWITCHING CURRENT MAX. A 0.5 0.6 0.25
The RSF50 series of floatswitch are miniature vertically mounted
devices designed to achieve reliable, economical liquid level sensing
with a minimum of insertion time. Manufactured in PVC, Nylon, PPS
and Polypropylene, most commonly used fluids are catered for (refer
to the factory for specific suitability details). Mounting is simple and
quick from the inside of the tank, nut and washer supplied. Many
variants carry WBS and UL approval.
• Reliable reedswitch contacts
• Available in Nylon, Polypopylene or PPS
• User configurable N/O or N/C operation
• Quick and simple to install
• WBS Approved
• Variety of switching options and available with 1/8" NPT taper thread
• Many variants are UL recognised components FILE No. E171218
TECHNICAL SPECIFICATION RSF51/52 RSF53 RSF54 RSF56
MATERIAL PVC NYLON POLYPROPYLENEPOLYPHENYLENE
SULPHIDE (PPS)
COLOUR LIGHT GREY BLACK OPAQUE GREY
TEMP. RANGE °C
°F
-20 / +60
-4 / +140
-20 / +75
-4 / +167
-20 / +100
-4 / +212
-10 / +120
+14 / +248
MIN. FLUID S.G. 0.7 0.8 0.8 0.85
79
PRESSURE SWITCHES
SWITCHES
PRESSURE SWITCH FOR PRESSURE UP TO 28 BAR
PRESSURE SWITCH FOR PRESSURE UP TO 300 BAR
SHUTDOWN PRESSURE SWITCH WITH MANUAL RESET
• Sensitive element with Stainless Steel Diaphragm
• Metal Frame
• Shock-proof Thermoplastic Cover
• Compliance with standards CEI EN 60947-4-1
* The differential is subtracted from the scale value
• The storage and transport temperature
corresponds to the pressure switch body
admissible temperature
ELECTRIC SPECIFICATIONSRATED INSULATION VOLTAGE Ui 415V~
CONTINUOUS DUTY RATED CURRENT lth 16A
RATED OPERATING CURRENT IE:
220V~ 380/415V~
RESISTANCE LOAD AC-1 — 10A
INDUCTIVE LOAD AC-3 — 6A
DIRECT CURRENT DC-13 0,2A —
• Sensitive element with stainless steel diaphragm
• Metal frame
• Shock-proof thermoplastic cover
• Compliance with standards CEI EN 60947-4-1
* The differential is subtracted from the Range value
• The storage and transport temperature
corresponds to the pressure switch body admissible
temperature
ELECTRIC SPECIFICATIONSRATED INSULATION VOLTAGE Ui 415V~
CONTINUOUS DUTY RATED CURRENT lth 16A
RATED OPERATING CURRENT IE:
220V~ 380/415V~
RESISTANCE LOAD AC-1 — 16A
INDUCTIVE LOAD AC-3 — 6A
DIRECT CURRENT DC-13 0,2A —
• Sensitive element with stainless steel diaphragm
• Calibration screw designed to be sealed after testing.
• Metal frame, shock-proof thermoplastic cover
• Compliance with standards CEI EN 60947-4-1
• I.S.P.E.S.L. approval
* The differential is subtracted from the Range value
• The storage and transport temperature
corresponds to the pressure switch body
admissible temperature
ELECTRIC SPECIFICATIONSRATED INSULATION VOLTAGE Ui 415V~
CONTINUOUS DUTY RATED CURRENT lth 16A
RATED OPERATING CURRENT IE:
220V~ 380/415V~
RESISTANCE LOAD AC-1 — 16A
INDUCTIVE LOAD AC-3 — 6A
DIRECT CURRENT DC-13 0,2A —
RANGE DIFFERENTIAL *MAXIMUM PRESSURE
OF SENSITIVE ELEMENTCONNECTION
PRESSURE SWITCH BODY
ADMISSIBLE TEMPERATURE •PROTECTION
LEVEL
B12CN -0,2 TO 8 BAR 0,6 TO 3 BAR 9 BAR G 1/4 FEMALE -35 to 60°C IP40
B12DN 5 TO 16 BAR 1 TO 3,5 BAR 18 BAR G 1/4 FEMALE -35 to 60°C IP40
B12EN 8 TO 28 BAR 6 TO 29 BAR 29 BAR G 1/4 FEMALE -35 to 60°C IP40
B12CRN -0,2 TO 8 BAR 3 TO 9 BAR 9 BAR SAE 1/4" -35 to 60°C IP40
B12ERN 8 TO 28 BAR 6 TO 29 BAR 29 BAR SAE 1/4" -35 to 60°C IP40
RANGE DIFFERENTIAL *MAXIMUM PRESSURE
OF SENSITIVE ELEMENTCONNECTION
PRESSURE SWITCH BODY
ADMISSIBLE TEMPERATURE •PROTECTION
LEVEL
B12FN 12 TO 50 BAR 6 TO 15 BAR 60 BAR G 1/4 MALE -35 TO 60°C IP40
B12GN 25 TO 150 BAR 12 TO 40 BAR 180 BAR G 1/4 MALE -35 TO 60°C IP40
B12HN 60 TO 300 BAR 40 TO 80 BAR 350 BAR G 1/4 MALE -35 TO 60°C IP40
RANGE DIFFERENTIAL *MAXIMUM PRESSURE
OF SENSITIVE ELEMENTCONNECTION
PRESSURE SWITCH BODY
ADMISSIBLE TEMPERATURE •PROTECTION
LEVEL
B12FN 1 TO 5 BAR 0,6 BAR FIXED 9 BAR G 1/4 FEMALE -35 TO 60°C IP40
80
SWITCHES
PRESSURE SWITCHES
PA-604 AIR DIFFERENTIAL PRESSURE SWITCH
TECHNICAL OVERVIEWThe PA-604 range are high sensitivity air differential pressure
switches for low differential pressure switching applications.
Suitable for use in air conditioning systems to provide an indication
of fan status or 'filter dirty' condition. The switching knob is mounted
under the cover to avoid tampering. The scale is individually laser
etched for high accuracy.
FEATURES• Snap fit cover
• Duct fixing kit included
• IP65 enclosure kit option
NOTEA duct fixing kit is supplied with the PA-930. It consists of 2m
of 6mm Dia. plastic tubing, 2 x pitot tubes, and 4 x fixing screws.
SPECIFICATION
OPERATING RANGES
TYPE ADJUSTMENT
RANGE
SWITCHING DIFFERENTIAL
(FACTORY SET)
PA-604-90 20 – 300PA 0.08 – 0.25 MBAR
PA-604-91 50 – 500PA 0.18 – 0.38 MBAR
PA-604-92 100 – 1000PA 0.28 – 0.67 MBAR
PA-604-94 500 – 2000PA 0.6 – 1.35 MBAR
MAX. OPERATING
PRESSURE5000PA 50 MBAR
PRESSURE
CONNECTIONS6MM ID PUSH-ON TUBING
ELECTRICAL RATING 5A (0.8A)230VAC
CONNECTIONS SCREW TERMINALS
DIMENSIONS 81MM DIA. X 52MM
HOUSING MATERIAL PLASTIC MOULDING
FIXING METAL MOUNTING BRACKET
PROTECTION IP54 (IP65 ENCLOSURE KIT OPTION)
AMBIENT RANGE -30C TO +85C
INSTALLATION
CATEGORYIEC 664 CATEGORY II
WEIGHT 160G
ORIGIN Switzerland
PRODUCT CODES
TYPE ADJUSTMENT
RANGE
SWITCHING DIFFERENTIAL
(FACTORY SET)
PA-604-90 20 – 300PA Air Differential Pressure Switch
PA-604-91 50 – 500PA Air Differential Pressure Switch
PA-604-92 100 – 1000PA Air Differential Pressure Switch
PA-604-94 500 – 2000PA Air Differential Pressure Switch
PA-604-90-IP65 200 – 300PAEnclosure kit with fitted
pressure switch
PA-604-91-IP65 50 – 500PAEnclosure kit with fitted
pressure switch
PA-604-92-IP65 100 – 1000PAEnclosure kit with fitted
pressure switch
PA-604-94-IP65 500 – 2000PAEnclosure kit with fitted
pressure switch
OPTIONAL ACCESSORIES
PA-DFK Duct fixing kit
PA-TEE Tee piece pack of 10
PA-TUBE-8MM PVC Tub, 8mm o/d, 30m rell
81
1 Common
2 NC Contact
3 No Contact1
2
3
INSTALLATION1. The PA-604 should only be installed by a competent, suitably
trained technician, experienced in installation with hazardous
voltages. (>50Vac & <1000Vac or >75Vdc & 1500Vdc)
2. Ensure that all power is disconnected before carrying out any
work on the PA-604.
3. It is recommended that the unit be mounted vertically, with the
pressure ports pointing downwards (Fig.1). If the unit is mounted
horizontally (Fig.2) with the cover uppermost, the switching points
will be 11PA higher than the scale reading. If the unit is mounted
horizontally (Fig.3) with the cover facing downwards, the switching
points will be 11PA lower than the scale reading.
APPLICATIONIf the switch is to be used for filter status monitoring, the Pitot
tube ends should be cut square. If the switch is to be used for
fan status monitoring, the ends of the Pitot tube should be cut
at an angle of 45°.
SWITCHES
PRESSURE SWITCHES
PA-604 AIR DIFFERENTIAL PRESSURE SWITCH
FIGURE STATUS MONITORING
The switch can be used across a fan to provide proof of air
flow and hence fan status (Fig.4) shows how to connect the
High and Low pressure ports:
The switch can be used across a filter to provide dirty filter
status (Fig.5) shows the connections for this application.
CAUTIONThe PA-604 will be damaged if subjected to excessive pressure.
Do not test the unit by blowing into the inlet ports.
CONNECTIONS
Fig. 1 Fig. 2 Fig. 3
Fig. 4
Fig. 5
82
SWITCHES
AUTOMATIC RESET PRESSURE CONTROL
ILPS/IHPS SERIES
SPECIFICATIONS
S.P.S.T – NORMALLY CLOSED CONTROL S.P.S.T – NORMALLY OPEN CONTROL S.P.S.T – NORMALLY CLOSED CONTROL
FEATURES• Snap-acting stainless steel, hermetically sealed sensor
• Corrosion resistant stainless steel crimp-ring
• Gold plated contacts are also available
• Wide variety of fittings and electrical connections
• Available in environmentally sealed or vented switch
• Excellent set-point repeatability/stability
APPLICATION• Residential and commercial air-conditioning, refrigeration
& heat pump applications.
• Service equipment including recovery and recycling machines.
OPERATIONAs the system pressure reaches above or below a preset value,
the snap-acting stainless steel diaphragm reverses its curvature,
opening or closing a set of electrical contacts trhough a transfer
pin. The control automatically resets when the pressure falls
within the factory preset pressure values.
DESIGN SPECIFICATIONS
CONFIGURATIONSPST or SPDT
NO or NC Contacts
FACTORY PRESET
PRESSURE RANGE
0 to 700 PSIG (0 to 48,2 Bar)
PROOF PRESSURE
250 PSIG (17,2 Bar) for set-point < 100 PSIG (<6,9 Bar)
600 PSIG (41,4 Bar) for set-point < 500 PSIG (<34,4 Bar)
800 PSIG (55,2 Bar) for set-point < 500 PSIG (<34,4 Bar)
BURST PRESSURE 5,000 PSI (344,8 Bar)
LIFE AT
RATED LOAD100,000 cycles
ELECTRICAL
RATING
24 VAC – 125 VA Pilot Duty
120/240 VAC – 375 VA Piloy Duty
120/240 VAC – 6 FLA, 36 LRA
DIELECTRIC
STRENGTH
750 Vrms Open Contacts
1,550 Vrms Terminals to Fitting
TEMPERATURE
RATING
AMBIENT -20 F to 176 F ( -30 C to 80 C)
FLUID -60 F to 275 F ( -50 C to 135 C )
WIRE LEADS
18 AWG, 600 V, 105 C, 1/32" insulated PVC
18 AWG, 600 V, 125 C, 1/16" insulated XLP
* Other leads are also available
CH C
HC
L
H(CUT-OUT ON HIGH) (CUT-OUT ON LOW) (CUT-OUT ON HIGH)
83
SWITCHES
AUTOMATIC RESET PRESSURE CONTROL
ILPS/IHPS SERIES
ILSP / IHPS
Series
ILPS: NO
(Open on Pressure Rise)
IHPS: NO
(Open on Pressure Fall)
Auto ResetL Pressure Control
Close0 to 700 PSI
(O to 48,2 Bar)
TerminationSignifies Lead Length in inches00: 1/4" Male Spade Terminals06 to 72: 6" to 72" Wire Leads
Tolerance (In PSI)C: +/– 3D: +/– 4E: +/– 5F: +/– 6G: +/– 7H: +/– 8J: +/– 9K: +/– 10L: +/– 11M: +/– 12N: +/– 13P: +/– 14R: +/– 15Y: +/– 20Z: +/– 30
Fittings0: 1/4" Female Flare with Deflator1: 1/8" Male Pipe Thread2: 1/4" Male Pipe Thread4: 1/4" Solder7: 3/32" Copper Capillary Tube
LMT C180
Open0 to 700 PSI
(O to 48,2 Bar)
LMT C
STANDARD MODELS
ITEM MODEL OPEN PSI (Bar) CLOSE PSI (Bar)
7007 ILPS-018-033C015E 3 +/-3 (0,2) 15 +/-3 (1,0)
7024 ILPS-018-007CO22E 7 +/-3 (0,5) 22 +/-5 (1,5)
7034 ILPS-018-010C025E 10 +/-3 (0,7) 25 +/-5 (1,7)
7048 ILPS-018-020C040E 20 +/-3 (1,4) 40 +/-5 (2,8)
7057 ILPS-018-025C050E 25 +/-3 (1,7) 50 +/-5 (3,5)
7063 ILPS-018-025C080E 25 +/-3 (1,7) 80 +/-5 (5,5)
7075 ILPS-018-040C080E 40 +/-3 (2,8) 80 +/-5 (5,5)
7215 IHPS-018-200K150K 200 +/-10 (14) 150 +/-10 (10)
7217 IHPS-018-250K150K 250 +/-10 (17) 150 +/-10 (10)
7221 IHPS-018-300K200K 300 +/-10 (21) 200 +/-10 (14)
7228 IHPS-018-350K250K 350 +/-10 (24) 250 +/-10 (17)
7241 IHPS-018-400K200K 400 +/-10 (27) 200 +/-10 (14)
7258 IHPS-018-425K350K 425 +/-10 (29) 350 +/-10 (24)
84
SWITCHES
SELECTOR SWITCHES 22Φ/25Φ
NSS22 -S 2 11 G A 1 2 3 4 5 6
1. SERIES
NSS22 NON-ILLUMINANTED
NLS22 ILLUMINANTED
3. POSITION
2 2 POSITION
1 2 POSITION (SPRING RETURN)
3 3 POSITION
0 3 POSITION (SPRING RETURN)
2. TYPE
NSS22 NLS22
S NORMAL SHAFT S NORMAL SHAFT
L LONG SHAFT L LONG SHAFT
K KEY
5. CAP COLOUR
NSS22 NLS22
R RED R RED
G GREEN G GREEN
Y YELLOW Y YELLOW
B BLACK
MODEL DESIGNATION
NON-ILLUMINANTED AND ILLUMINANTED
NSS22-S2 NLS22-S2
2 Positions 90º
1 2
3 Positions 45º
10
2
2 Positions 90º(Spring Return)
1 2
3 Positions 45º(Spring Return)
10
2
6. VOLTAGE RATING
NLS22
A AC.DC 24V
E AC.DC 100~120V
I AC.DC 220~240V
4. CONTACT BLOCKS
10 1A 21 2A1B
01 1B 12 1A2B
11 1A1B 22 2A2B
20 2A 01 2B
85
SWITCHES
SELECTOR SWITCHES 22Φ/25Φ
NON-ILLUMINANTED AND ILLUMINANTED
NSS22-S3
NSS22-L2
NSS22-L3
NSS22-K2
NLS22-S3
NLS22-L2
NLS22-L3
NSS22-K3
86
TEMPERATURE CONTROLLERS
VT48206 FUZZY PID CONTROLLER
FEATURES
PANEL, DESCRIPTION & KEYS OPERATION
• T/C, RTC, Linear Input Selectable
• Fuzzy enhanced PID Control
• Auto / Manual Bumpless Transfer
• Universal Power Supply: 90~264VAC, 50/60Hz,
or DC/AC24V is also available for option
• Standard Model with 2 Alarm outputs
• Standby and Latch mode can be combined with
8 different alarm functions
• Ramp to set point and Soack functions, and Soft-start function
• Retransmission or RS485 communication (MODBUS RTU)
or 4~20mA remote-setpoint is available for option
SPECIFICATION
INPUT
Thermocouple (J, K, R, S, T, E, B, N, C type)
DIN Pt100Ω or JIS Pt100Ω
Linear (4~20mA, 0~50mV, 0~1V, 0~5V, 0~10V...)
ACCURACY± 1°C for Thermocouple Input
± 0.2°C for Pt100Ω ; ±3mV for Linear Input
SAMPLE TIME 0.5 sec.
CONTROL MODE
P.bond 0.0~300.0% F.S. for P control
Integral Time 0~3600 sec.
DeRIVATIVE Time 0~900 sec.
Hysteresis Range 0.0~200.0 or 0~2000
Cycle Time 0~100 sec.
CONTROL CYCLE
Relay Contact Output 15 sec.
Pulsed Voltage to drive SSR: 1 sec.
Continuous Voltage (Current) Output: 0 sec.
OUTPUT MODE
Relay Contact Output 10A/240VAC (Resistive Load)
Pulsed Voltage to drive (SSR) DC 0/24V (Min. 250 ohm)
Continuous Current Output 4~20mA (Max. 600 ohm)
Continuous Voltage Output 0~1V, 0~5V, 0~10V (Max. 600 ohm)
GENERAL
OPERATION
Rated Power Supply Voltage 90~264VAC, 50/60H ; DC 24V
Ambient Temperature 0~50°C
Ambient Humidity 0~90%
Power Consumption under 5VA
WIRING DIAGRAM
PANEL CUTOUT WIDTH HIGH DEPTH
(Unit:mm) 45+0.5 45+0.5 100
SYMBOL DESCRIPTION ALARM OUTPUT OPERATION
No Alarm Function Alarm Output OFF
PV High Alarm
PV Low Alarm
Deviation High Alarm
Deviation Low Alarm
Band High Alarm
Band Low Alarm
On-Timer
Off-Timer
87
TEMPERATURE CONTROLLERS
VT48206 FUZZY PID CONTROLLER
ERROR MESSAGE AND TROUBLESHOOTING
LOCK SETTING / ALARM MODE (A1MD/AMD)
HOW TO ORDER
MESSAGE PROBABLE SOLUTION
1) Sensor Break Error2) Sensor not be connected
1) Replace Sensor2) Check the Sensor be connected correctly
1) Input Signal over the High Limit2) Incorrect Input Sensor Selection
1) Set a Higher Value to High Limit2) Check connecting Input & Set Correct TYPE
1) Input Signal below the Low Limit2) Incorrect Input Sensor Selection
1) Set a Lower Value to Low Limit2) Check connecting Input & Set Correct TYPE
KEYPAD
NO FUNCTION
1) Keypads be locked2) Keypads Defective
1) Change "Lock: Setting with proper Value2) Replace Keypads
NO HEAT
OR OUTPUT
1) No Heater Power or Fuse Open2) Defective or Incorrect Output used
1) Check Output wiring and fuse2) Replace Output Device
NO ANY DISPLAY1) No Power to Controller2) SMPS Failure
1) Check wiring for Power Source2) Replace SMPS
PV CHANGED
ABNORMALLY
1) Electromagnetic Interference (EMI) or Radio Frequency Interference (RFI) 1) Suppress arcing contacts in System to eliminate High Voltage Spike Sources. Separate Sensor & Controller wiring from "dirty: power lines. Ground Heaters.
DATA LOST 1) Fail to Enter Data to EEPROM 1) Replace EEPROM
A/D Converter Damage 1) Check for Outside Source of Damage (Ex: Transient Voltage Spikes)2) Unit must be repaired or replaced
MESSAGE PROBABLE
All Parameters are locked
Only SV is Adjustable
Only 1st Level is Adjustable
1st & 2nd Levels are Adjustable
1st, 2nd, 3rd Levels are Adjustable
All Parameters are Opened
1000=000, 1001=0001, 1010=00101011=0011, 1100=0100But Output 2 is Opened
MESSAGE PROBABLE
Normal Alarm Mode
Standby Mode when selected, in any Alarm Function presents an Alarm on power on. The alarm is enable only when the PV reach alarm set-point. Also known as "Startup Inhibit" and is useful for avoiding alarm trips during startup.
Latch mode. When selected, the alarm output and indicator latch as the alarm occurs. The alarm ouput and indicator will be energised even if the alarm condition has been cleared unless the power is shut off.
Standby and Latch Mode
88
TEMPERATURE CONTROLLERS
SPECIFICATIONS
DISPLAY Within 0.2% of displayed value + 1 digit
SAMPLING TIME 250m
OUTPUT MODE
Relay Outout
Voltage Output
Linear Output
Motor Control Output
Others
Contact, SPDT, 3A/240Vac
Voltage Pulse, 20VDC/20mA
4~20mA, 0~5V, 0~10V, 1~5V, 2~10V
Proportional motor 3 wired close loop circuit control
1φSSR, 3φSSR, 1φSCR, 3φSCR
GERNERAL SPECIFICATIONS
Power Consumption
Ambient Temperature
Ambient Humidity
4VA
0°C ~ 50°C
50 ~ 85 % (Non-dew)
MICROPROCESSOR CONTROLLER
FY900 / FY800 / FY700 / FY600 / FY400 SERIES
PANEL CUTOUT (UNIT:MM)
HOW TO ORDER
• Multi range Imput (TC, RTD, mV, mA) each 14Bit Resolution
• Auto/Manual Operation & Fuzzy/PID Control
• E²PROM Non-volatile memory
• Self-Diagnosis Function and Data Lock Function
• Free Power Range AC85~265V/DC15~50V
• Duplex Output Mode (Heat/Cool), Auxiliary Output PV, SV Retransmission
• 17 Alarm modes available, & option up to 3 Alarm sets
• Implement Zero/Phase Control by trig SCR Module directly
• RS232 & RS485 communication
• 2 Patterns each 8 segments programming procedure available
• 2nd Input can be used in Remote-SV
MODEL NO. SIZE OUTLINE (WxH) A B C D
FY900 1/4 DIN 96.0 + 96.0 90.5 + 0.5 90.5 + 0.5 111 116
FY800 1/8 DIN 50.0 + 96.0 44.5 + 0.5 90.5 + 0.5 65 116
FY700 68x68mm 74.0 + 74.0 68.5 + 0.5 68.5 + 0.5 89 94
FY600 1/8 DIN 96.0 + 50.0 90.5 + 0.5 44.5 + 0.5 111 70
FY400 1/16 DIN 50.0 + 50.0 44.5 + 0.5 44.5 + 0.5 65 70
89
TERMINALS
FEED-THROUGH TERMINALS
FEED-THROUGH TERMINALS
FEED-THROUGH TERMINALS
– SCREW CLAMP CONNECTION
– MATERIAL PA66
– RAIL MOUNT ON TS32/TS35
OR DIRECT MOUNTING
HT-2.5 HT-4 HT-10
QTY. P. PCK. (G/PCS) 1320/200 1100/100 1630/100
TERMINAL WIDTH 5.1mm 6.2mm 8.4mm
INSULATION STRIPPING LENGTH 7mm 11.5mm 12mm
CONDUCTOR
CROSS-SECTION
SOLID 0.2 – 4 0.2 – 6 0.2 – 10
STRANDED 0.2 – 2.5 0.2 – 4 0.2 – 10
AWG 22 – 12 22 – 10 22 – 8
ELECTRICAL RATINGS VOLTAGE V CURRENT A VOLTAGE V CURRENT A VOLTAGE V CURRENT A
VDE 750 26 750 34 750 55
DE 600 24 600 30 600 50
UL 600 20 600 30 600 50
END PLATE EP-4 EP-4 EP-4
CROSS-CONNECTION HT-2.5-47 HT-4-47 HT-10-47
END BRACKET HT-5 or HT-5N HT-5 or HT-5N HT-5 or HT-5N
COLOUR Grey, Pear Grey, Pear Grey, Pear
APPROVALS
FEED-THROUGH TERMINALS
FEED-THROUGH TERMINALS
– SCREW CLAMP CONNECTION
– MATERIAL: PA66
– RAIL MOUNT ON TS35
HT-4E HT-10E HT-16E
QTY. P. PCK. (G/PCS) 1540/50 1680/50 1072/20
TERMINAL WIDTH 9mm 6.2mm 8.4mm
INSULATION STRIPPING LENGTH 11.5mm 11.5mm 12mm
CONDUCTOR
CROSS-SECTION
SOLID 0.2 – 6 0.2 – 6 0.2 – 10
STRANDED 0.2 – 4 0.2 – 4 0.2 – 10
AWG 22-10 22-10 22-8
RATED SURGE VOLTAGE 8kV 8kV 12kV
CONTAMINATION CLASS 3 3 3
COLOUR Green/Yellow Green/Yellow Green/Yellow
APPROVALS
C US®
C US®
C US®
C US®
C US®
C US®
90
TERMINALS
FEED-THROUGH TERMINALS
TERMINALS
FEED-THROUGH TERMINALS
– SPRING CLAMP CONNECTION
– MATERIAL: PA66
– RAIL MOUNT ON TS32/TS35
OR DIRECT MOUNTING
– END BRACKETS
– END PLATES
– MARKING MATERIAL
HTP-4 HT-2.5-4.7 HT-4-47
QTY. P. PCK. (G/PCS) 1140/100
TERMINAL WIDTH 6.2mm
INSULATION STRIPPING LENGTH 11.5mm
CONDUCTOR
CROSS-SECTION
SOLID 0.2 – 6 HTP-10-47 HTP-16-47
STRANDED 0.2 – 4
AWG 22 – 10
ELECTRICAL RATINGS VOLTAGE V CURRENT A
VDE 750 34
DE 600 32
UL 600 30
END PLATE EPP-4
END BRACKET HT-5 or HT-5N
COLOUR Grey, Pear
APPROVALS —
TERMINALS
HT-5 HT-2.5-01C HT-4-01C HT-35-47
HT-5N
EPF-1 EPP-4 EP-4 EP-16 EP-35
COLOUR BLUE, GREY
COLOUR PEAR, GREY
1~ 10
∫
91~100
A~Z
PE
91
FEED-THROUGH TERMINALS
TERMINALS
FEED-THROUGH TERMINALS
FEED-THROUGH TERMINALS
AND ASSEMBLIES
– SCREW CLAMP CONNECTION
– MATERIAL: PC
– RAIL MOUNT ON TS35
NHT-10 NHT-20 NHT-30
QTY. P. PCK. (G/PCS) 760/100 1060/100 1400/100
TERMINAL WIDTH 9mm 10.6mm 13.2mm
HEAT DEFLECTION °C 130°C 130°C 130°C
AWG 22 – 16 22 – 14 22 – 12
ELECTRICAL RATINGS VOLTAGE V CURRENT A VOLTAGE V CURRENT A VOLTAGE V CURRENT A
CE/CSA/UL 600 10 600 20 600 30
END PLATE NHT-10-02 NHT-10-02 NHT-10-02
COLOUR Black Black Black
APPROVALS
FEED-THROUGH TERMINALS
FEED-THROUGH TERMINALS
AND ASSEMBLIES
– SCREW CLAMP CONNECTION
– MATERIAL: PC
– RAIL MOUNT ON TS35
NHT-60 NHT-100 NHT-200
QTY. P. PCK. (G/PCS) 3170/88 4310/50 195/1
TERMINAL WIDTH 22.5mm 32mm 39.5mm
HEAT DEFLECTION °C 130°C 130°C 130°C
AWG 12 – 6 6 – 2 2 – 3/0
ELECTRICAL RATINGS VOLTAGE V CURRENT A VOLTAGE V CURRENT A VOLTAGE V CURRENT A
CE/CSA/UL 600 60 600 100 600 240
POLE 1P 1P 1P
COLOUR Black Black Black
APPROVALS
FEED-THROUGH TERMINALS
FEED-THROUGH TERMINALS
AND ASSEMBLIES
– SCREW CLAMP CONNECTION
– MATERIAL: PC
– RAIL MOUNT ON TS35
NHT-2 NHT-3.5 NHT-8
QTY. P. PCK. (G/PCS) 21/1 35/1 60/1
TERMINAL WIDTH 25.8mm 35.5mm 43.5mm
HEAT DEFLECTION °C 130°C 130°C 130°C
AWG 22 – 14 22 – 12 12 – 8
ELECTRICAL RATINGS VOLTAGE V CURRENT A VOLTAGE V CURRENT A VOLTAGE V CURRENT A
CE/CSA/UL 600 20 600 30 600 50
POLE 3P 3P 3P
COLOUR Black Black Black
APPROVALS
92
TERMINALS
FEED-THROUGH TERMINALS
TERMINALS
NHT-2-06A NHT-3.5-06A NHT-8-06A NHT-14-06A
NHT-22-06A NHT-38-06A NHT-200-06A NHT-10-06
TERMINALS
NHC-10-02 NHC-20-02 NHC-30-02 NHT-30-06
NHC-60-02 NHC-100-02 NHT-10-53 NHT-20-53 12D-53 18D-53
93
THERMOCOUPLE & RTD PROBES
THERMOCOUPLE & RTD PROBES
ORDERING GUIDE
We offer a variety of Thermocouple
& RTD Probes as custom sizes.
Welcome custom sketches for
consulting price and availability.
Fig. 1 RTD Element
Fig. 2 Probe Head &
Terminal Block
Fig. 3 Leads Wire
Fig. 4 Thermowell & Fitting
Fig. 1 Fig. 2 Fig. 3 Fig. 4
94
TIMERS
MDUV 480 – UNIVERSAL TIMERS
FEATURES
SPECIFICATIONS
ORDER NUMBER
• All Solid State, no moving contacts.
• Operating voltage 19 – 299V AC or DC
• 0.1 to 8 minutes time adjustable by knob with dial
• Digital Timing Circuit
• Good Repeat Accuracy
• Two Terminal Series Connection
• Epoxy Encapsulated
TIME
RANGE 0.1 to 8min (Knob adjustable with dial)
REPEAT ACCURACY ± 2% (Under fixed conditions)
RECYCLE TIME 40mx Max. (After timing)
VOLTAGE
RANGE 19 to 288 Volts AC or DC
FREQUENCY DC or AC 60Hz/50Hz
OUTPUT
TYPE Solid State
MAX. CURRENT 1 Amp steady state, 10 Amps in-rush at 55°C
MIN. CURRENT 40 mA
VOLTAGE DROP Typical 2.5V at 1 Amp current
PROTECTION
INTERNAL VARISTOR
MIN. 1500 Vrms Dielectric Breakdown
MAX. 100MΩ insulation resistance (Test at 500VDC)
TEMPERATURE
OPERATING TEMP. -20°C to +70°C
STORAGE TEMP. -30°C to +80°C
Upon application of input voltage, the load de-energizes ad the time
delay is initiated. At the end of the delay time, the load energizes.
Reset is accomplished by removing input voltage.
M D U V 480 1 2 3 4 5
1. OPERATION MODE M – Delay On Make
2. CIRCUIT TYPE D – Digital Circuit
3. OPERATING VOLTAGE U – Universal Range 19 - 288V
4. ADJUSTMENT TYPE V – Variable Resistor Built-in
5. TIME RANGE 480 – Delay Time Max. 480 Sec.
DIMENSIONS
CONNECTION
TIMING DIAGRAM
95
TIMERS
DELAY ON BREAK TIMERS
DELAY ON BREAK TIMERS
APPLICATION TIMING DIAGRAM MODE OF OPERATION
"Anti-short Cycle"
"OFF delay on break"
Helps to protect air conditioning,
refrigeration and heat pump equiptment
from damage which may be caused by the
rapid short cycling of compressors.
Upon application of power, the load is energized.
When the thermostat or other switch opens, or
there is a loss of power, the load is de-energized
and the delay period begins. The compressor will
not start again during the delay period. Restart
occurs after the delay period.
ICM CONTROL SERIES FEATURES/APPLICATIONS SPEC REPLACES
ICM200
ICM200F
ICM201
ICM201F
• Higher 1.5 Amp Rating
• Compressor lockout/anti-shock
cycle timer
• Helps to protect compressors from
damage caused by rapid short cycling
• Simple, 2-wire hookup
• Compact, 2" x 2" package
• F suffix denotes 6" wire leads
(shown at left)
• ICM200 has 3min. delay
• ICM201 has 5min. delay
• 18 – 30VAC
• 1.5 Amps
• 15 Amp inrush
• 3 or 5min. fixed
time delays
• Voltage Drop:
3.5V Typical
4.5V Max
• Frequency:
50/60Hz
• Requires 40mA
holding current
• Diversified:
ASC-500, 501
ASC-502
ASC-505-5
• Gemline:
IC321
IC322
• Watsco:
EAC-500
EAC-501-180-W
EAC-501-300-W
ICM203
ICM203F
• Universal Voltage Operation
• Higher 1.5 Amp power rating
• Compressor lockout/anti-shock
cycle timer
• Helps to protect compressors from
damage caused by rapid short cycling
• Simple, 2-wire hookup
• Compact, 2" x 2" package
• F suffix denotes 6" wire leads
• Works with anitcipator-type thermostats
• 18 – 240VAC
• 1.5 Amps
• 15 Amp inrush
• Knob-adjustable
delays .03-10 min.
(1.8 – 600 sec.)
• Voltage Drop:
3.5V Typical
4.5V Max
• Frequency:
50/60Hz
• Requires 40mA
holding current
• Diversified:
ASC-500, 501
ASC-502
ASC-505-5
• Gemline:
IC320
• Mars:
32392
• Robertshaw:
3310-072
• Supco:
TD-73
• Watsco:
EAC-500
EAC-501-180-W
EAC-501-300-W
DELAY ON BREAK TIMERS - ULTRA LOW COST
ICM CONTROL SERIES FEATURES/APPLICATIONS SPEC REPLACES
ICM207
ICM208
ICM209
• Universal Voltage Operation
• Higher Voltage Operation
• Help prevent scroll compressor reversal
• Fast response time: 16 ms.
• Eliminates relay chatter due to
thermostat bouncing or tampering
• Works with anitcipator-type thermostats
• Compact, epoxy-encapsulated package
• ICM207 has 3 min. delay
• ICM208 has 5 min. delay
• ICM209 has 10 min. adjustable delay
• 18 – 240VAC
• 1 Amps
• 1 Amp inrush
• 3 or 5min. fixed
or 10min.
• Voltage Drop:
2.5V at 1 Amp
• Frequency:
50/60Hz
• Requires 40mA
holding current
N/A
96
BYPASS TIMERS
TIMERS
BYPASS TIMERS
APPLICATION TIMING DIAGRAM MODE OF OPERATION
"ON delay interval timer"
"Normally closed delay on make"
Designed to bypass a control or device
during startup. Typically used to bypass a
low pressure switch during compressor
startup or to bypass an oil pressure
switch upon startup. Helps to eliminate
nuisance lockouts.
With power applied to the input, the load
energizes immediately and remains energized
for the length of the time delay, regardless of
the state of the switch being bypassed. At the
end of the time delay the condition of the load
is determined by the state of the switch.
ICM CONTROL SERIES FEATURES/APPLICATIONS SPEC REPLACES
ICM175
• Designed to bypass a low pressure switch
or other device during startup
• Ideal for low ambient startups
• Integral component for "winter start" kits
• Helps to reduce nuisance lockouts
• Universal AC Voltage operation
• Knob-adjustable time delays
• Epoxy-encapsulated circuitry
• 18 – 30VAC
• 1 Amps
• 10 Amp inrush
• Knob-adjustable
time delays:
10 – 1000 seconds
• Mars:
32395
• Supco:
TDP68
ICM305
(minutes)
ICM306
(seconds)
• Reliable duty cucle timer ideally suited
for defrost applications
• Suitable for process equipment or
applications requiring intermittent delays
• Switch-settable time delays
• Digital timing accuracy
• Reliable solid state output
• Epoxy-encapsulated for greater reliablility
• ICM305: Time delay in minutes
• ICM306: Time delay in seconds
• ON-Time starts with power up, OFF-Time
initiates after ON-Time, Timing cycle
repeats until power loss
• 18 – 240VAC
• 1 Amps
• 10 Amp inrush
Time Delay: ICM305
• Switch-settable
from: 1 – 1,023 min.
in 1 min. intervals
Time Delay: ICM306
• Switch-settable
from: 1 – 1,023 min.
in 1 min. intervals
N/A
97
DELAY ON BREAK
TIMERS
SERIES TBPS
MODE OF OPERATION
When the normally open initial contact closes, the delay is energized.
The load stays energized as long as the initial contact remains closed.
When the initial switch opens, the Delay Off period begins. When the time
delay period is complete, the load is de-energized. If the initial contact closes
during the OFF delay period, the load remains energized and the time delay
resets to zero.
The timer features three OFF time delay ranges (from 0.1 to 1,000 seconds)
available in any of four different moethods of adjustment.
• Universal Voltage
• Fixed or adjustable time delays up to 1,000 seconds
• Totally sold state circuitry
• Epoxy encapsulated
When the normally open initial contact closes, the delay is energized.
The load stays energized as long as the initial contact remains closed.
When the initial switch opens, the Delay Off period begins. When the
time delay period is complete, the load is de-energized. If the initial
contact closes during the OFF delay period, the load remains energized
and the time delay resets to zero.
TBPS - 00A 2 Y 02 1 2 3 4 5 5. TIME RANGE
01 0.1 to 10 Seconds
02 1 to 100 Seconds
03 10 to 1,000 Seconds
1.
Series
3. CONTROL METHOD
1 Fixed Time External
2 Local Adjust
5 Remote Adjust
9 Fixed Internal2. INPUT VOLTAGE
00A = 18 – 240 VAC
4. TOLERANCE
Y = ±10%
ORDERING INFORMATION
MODEL DESIGNATION
INPUT
NORMINAL VOLTAGE 18 – 240 VAC
TOLERANCE +/-20%
FREQUENCY 50/60 Hz
MAXIMUM ALLOWABLE DC RIPPLE
VOLTAGE20%
POWER CONSUMPTION .5 Watts Maximum
OUTPUT
TYPE Triac
RATING1.0 Amp max, 20 mA min,
10 Amp inrush
VOLTAGE DROP 2.5 Volts max. @ 1.0 Amp
LEAKAGE CURRENT 5 mA max. @ 240 VAc
TIME DELAYS
TYPE Fixed internal, Fixed External, Local
Adjust, Remote Adjust
RANGEFixed up to 1,000 seconds adjustable
0.1-10, 1-100, 10-1000 seconds
RESET TIME DURING ON OR
OFF PERIOD100 milliseconds
REPEAT ACCURACY +/-.5%
FIXED TIME TOLERANCE +/-10%
TIME DELAY VS. TEMP. AND VOLTAGE +/-5% maximum
ENVIRONMENTAL
OPERATING TEMPERATURE -40°C to +75°C
STORAGE TEMPERATURE -40°C to +85°C
TRANSIENT PROTECTION
+/-1,400 VOLTS FOR 100 MICROSECONDS
98
AH3- SERIES
TIMERS
FEATURES
CONNECTION DIAGRAM OPERATION TIME CHART
• Two LED's provides status inducation, for power ON and time UP.
• Wide variety of type-14 ranges (0.1 sec. to 10 hrs.)
• Standard surface mounting could be easily converted into flush
mounting by adding a special adaptor. (Type Y-40)
TYPE AH3-� AH3-� +(Y-40) Adaptor
W x H x D mm (Dimensions) 40 x 50 x 58 45 x 54 x 59
AVAILABLE TYPES
TYPE
MOUNTING Surface Mounting AH3-1 AH3-2 AH3-3
Flushing Mounting Y-40 Y-40 Y-40
CONTROL
OUTPUT
Time-Limit Contact SPDT (SA) DPDT (SA) SPDT (SA)
Instantaneous Contact — — SPST-NO (SA)
CONNECTION & TIMING CHART 1. 2. 3.
TIME RANGE
RATED TIME TIME SETTING RANGE OPERATING VOLTAGE
1S 0.1S ~ 1S
3S 0.3S ~ 3S
6S 0.6S ~ 6S
10S 1S ~ 10S DC 12V
30S 3S ~ 30S DC 24V
60S 6S ~ 60S AC 110V 50/60Hz
3M 10S ~ 100S
6M 20S ~ 6M AC 120V 50/60Hz
10M 30S ~ 10M
30M 2M ~ 30M AC 220V 50/60Hz
60M 3M ~ 60M
3H 10M ~ 3H AC 240V 50/60Hz
6H 20M ~ 6H
10H 30M ~ 10H
SPECIFICATIONS
OPERATING VOLTAGEAC: 85 – 110% of rated voltage
DC: 80 – 110% of rated voltage
RATED VOLTAGEAC: 110V, 220V, 240V, 50/60Hz
DC: 12V, 24V
CONSUMED POWER About 2VA for AC: About 2W for DC
CONTROL METHOD Time-Limit Operating Self-resetting
CONTACT RATING AC: 120V 5.A. (p.f. = 1)
AMBIENT TEMP -10°C ~ +55°C
AMBIENT HUMIDITY 45 ~ 85%
CHARACTERISTICS
REPEAT ACCURACY Less than ± 1% of full scale
EFFECT OF VOLTAGE Less than ± 1%
EFFECT OF
TEMPERATURELess than ± 2% at 20°C
SETTING ACCURACY Less than ± 10% of full scale
RESET TIME 0.1, Less than 0.1 Sec.
INSULATION
RESISTANCEOver 50MΩ (DC500V)
DIELECTRIC AC 2000V one Min.
WEIGHT Approximately 160g
SHOCK RESISTANCE Incorrect Operate 10G
LIFEMECHANICAL 5,000,000 Operations
ELECTRICAL 100,000 Operations at rated load
VIBRATION RESIS-
TANCE
Incorrect Operate 10.55Hz 0.5mm
Durability 10.55Hz 0.5mm
AH3-1
AH3-2
AH3-3
99
TM/TR SERIES
TIMERS
FEATURES
FEATURES
DIAGRAMS
1. Manual Override
2. Easily Programmable
3. Captive pins. Many switching possibilities.
96 pins on daily dials.
4. Mark for time setting and programme reading
5. Time can be setting manually
• TM35-A 110V
• TM35-B 230V
• TM35-C 240V
DIAL
FREQUENCY SELECTOR
ARROW (TURNING DIRECTION)
PRESENT TIME (HOUR)
SETTING PIN (ON POSITION)
SETTING PIN (OFF POSITION)
POWER INDICATOR
TERMINAL COVER
POWER TERMINAL
CASE
PRESENT TIME
PRESENT CONTROL KNOB
MINUTE CONTROL KNOB
MANUAL SWITCH
LOAD TERMINAL
GROUND TERMINAL
CIRCUIT DIAGRAM
CIRCUIT DIAGRAM
ELECTRICMAGNETIC SWITCH ELECTRICMAGNETIC SWITCH
NOTE BEFORE OPERATING, TAKE OFF
ALL PROTECTIVE WIRE OF ELECTRO
MAGNETIC SWITCH SHOWN WITH
DOTTED LINES IN DIAGRAM.
100
DIGITAL TIMERS FOR DIN RAIL OR SURFACE MOUNTING
TIMERS
FEATURES
USE• Switching Timer Module where daily or weekly
programming is required, or for general use.
INSTALLATION AND OPERATION• Programming System using 7 control push buttons and
1 RESET button.
• Liquid Crystal Display showing the time, and the day of the week
• PROGRAM CAPACITY 8 ON and 8 OFF. Block program capacity
• 1 Minute between operations.
• Program check facility.
• Manual override capacity in Auto mode.
• 100 hrs back-up battery
• DIN rail EN50022-3 DIN46277-3 mounting.
TECHNICAL FEATURES• Compact Modular casing (2 moduls) in insulated thermoplastic
material, suitable for side by side mounting.
• Transparent cover to protect control buttons.
• 16 memories available. (8 ON-8 OFF).
• Timing accuracy ±1 min/month.
• II protection cclass to EN60335.
HOMOLOGATION AND STANDARD• Homologation TÜV.
ELECTRICAL FEATURES• Supply voltage 220V-250V 50/60Hz.
• Power consumption 4,4W.
• Electromagnetic out put relay with volt free contacts.
• 1,2Vdc NiMH battery.
• Out put contacts rated at 16(8)A 250V.
TYPE PROGRAMMINGAMBIENT
TEMPERATURE °CVOLTAGE
PROTECTION
DEGREEN° DEGREE WEIGHT BOX
W04C DAILY WEEKLY -10 TO 40 230V~250V 50/60HZ IP30 2 0.13
101
THERMOSTATS
ELECTRONIC DE-ICE THERMOSTAT
SOLID STATE DEFROST CONTROL
The ICM315 is a reliable, solid state replacement for E15-type controls.
It uses a thermistor-type probe as opposed to the unstable bulb-type
sensors used with E15 controls. The ntc-type probe of the ICM315
is less susceptible to breakage. Unlike E15 controls, the ICM315 is
not "position-sensitive" and therfore not susceptible to "re-initiation
phenomenon" which can cause damage due to system short-cycling.
The ICM315 features a built-in clip for easier mounting.
FEATURES• Solid State reliability...replaces unstable bulb-type sensors. Less
susceptible to breakage.
• Ultra Low Cost...without compromised performance.
• "No re-initiation phenomenon"...ICM315 is not position-sensitive.
• Quick, easy mounting... features built-in clip.
• ORDERING INFORMATION Order ICM P/N: ICM315.
SPECIFICATIONS
INPUT
• VOLTAGE 24, 120 or 240 VAC.
• FREQUENCY 50/60Hz
• POWER CONSUMPTION 1 watt max.
OUTPUT
• TYPE Relay
• FORM SPDT, n.o. : 20 Amps @ 240 VAC
n.c. : 10 Amps @ 240 VAC
INPUT
• DEFROST TIME Fixed at 10min. +/-20%
• INTERVAL TIME BETWEEN DEFROSTS 30/45/90 pin-selectable
• TEST TIME Short across DEF terminals reduces test time by 256X
MECHANICAL
• MOUNTING Surface mount using (4) #6 or #8 screws\
MODE OF OPERATIONThe ICM315 provides a selectable time interval (30,45,90 min.)
between 10 min. defrost cycles. Upon application of power the timing
sequence begins with the delay period first, and the 10 min. defrost
period second.
When the thermistor senses a temperature of 28°F of lower, the
defrost board will be controlled by its internal timer. The relay will be
energized every 30, 45 or 90 minutes based opon the post selected.
If, during the 10 min. defrost period, the temperature rises of 55°F
or greater, the defrost period will terminate. If this condition does
not occur, the defrost period will complete and the entire sequence
will repeat.
The on-board relay (K1) will be energized only during the 10 min.
defrost period.
CONNECTION DIAGRAM
C®
102
THERMOSTATS
DIGITAL ROOM THERMOSTAT
NHY-RTC100 MICROPROCESSOR CONTROL
WIRING DIAGRAM
FEATURES• Easy to Install.
• Contemporary Design for Simple Operation.
• Integral Design: All Outputs Built in
• Reverse Cycle and Heat Pump Application
• Heating and Cooling Manual/Auto changeover
• Accurate Temperature Control +/-1°C
• Displays Room and Setting Temperature
• 0.5 hour to 24 hour Delay Start or Stop Timer
• Temperature Range 15°C to 30°C
• Confort Sleeping Mode for Night Temperature
• Tamper-proof Settings
• Manual or Auto Fan
• Optional Remote Sensor
• Standard Wall Mounting Box
103
THERMOSTATS
ROOM THERMOSTATS
ROOM THERMOSTAT WITH VAPOR TENSION
ELECTRONIC ROOM THERMOSTAT
3 SPEEDS ELECTRONIC ROOM THERMOSTAT FOR FAN-COILS
• Sensitive element with electrically
welded stainless steel capsule
containing saturated vapour.
• Vapour pressure operation.
• Base, cover and knob in thermoplastic.
• Connection to the user with only 2 wires.
• Numerous signal and control variants.
• Compliance with standards
CEI EN 60730-1
• Contact rating: 10(2.5)A 250 VAC.
• Sensitive element with semiconductor sensor.
• Wall mounting.
• Double Insulation.
• SUMMER-WINTER-OFF switch for controlling
heating or air conditioning systems.
• Red LED to indicate relay cut-in, to request
heating (switch in winter position) or cooling
(switch in summer position).
• Compliance with standards CEI EN 60730-1
and second parts.
• Maximum dissipated power 1VA.
• Contact rating 6(1.5)A 250 V~.
• Voltage free switching contact.
• Sensitive element with semiconductor sensor.
• Wall mounting.
• Double Insulation.
• SUMMER-WINTER-OFF switch for controlling
heating or air conditioning systems.
• Manual switch for selecting one of the three
Fan-coil speeds.
• Compliance with standards CEI EN 60730-1
and second parts.
• Power Supply 230V ~ 50Hz
• Maximum dissipated power 1VA.
• Contact rating 6(1.5)A 250 V~.
SPECIFICATIONS
RANGE DIFFERENTIAL * ADMISSIBLE
THERMOSTAT BODY
TEMPERATURE •
MAXIMUM AMBIENT
TEMPERATURE
PROTECTION LEVEL
C16 10 to 30°C 0,8 K -10 to 50°C 45°C IP20 (normal pollution
TC16
Frame for mounting on: round box 60mm, screw fixing
round box with clips (not supplied)
round box distance between centres 75mm
* The differential is subtracted from the Range value. The differential values refer to a thermal gradient of 4K/hour in air.
• The stroage and transport temperature corresponds to the thermostat body admissible temperature.
CONTROL AND SIGNALLING VARIANTS
DESCRIPTION
C16L With Pilot Light
C16I With "ON-OFF" Switch
C16IL With "ON-OFF" Switch and Pilot Light
C16EH With "Summer-Winter" Switch
C16EHL With "Summer-Winter" Switch Switch and Pilot LIght
SPECIFICATIONS
RANGE DIFFERENTIAL * POWER SUPLY MAXIMUM AMBIENT
TEMPERATURE
PROTECTION LEVEL
C16 6 to 30°C ±0,5 K 230V - 50Hz 45°C IP20 (normal pollution
* The differential values refer to a thermal gradient of 4K/hour in air.
SPECIFICATIONS
RANGE DIFFERENTIAL * POWER SUPLY MAXIMUM AMBIENT
TEMPERATURE
PROTECTION LEVEL
C16 6 to 30°C ±0,5 K 230V - 50Hz 45°C IP20 (normal pollution
* The differential values refer to a thermal gradient of 4K/hour in air.
104
• Liquid expansion operation.
• Wall mounting of thermostat body.
• The bulb with capillary can be mounted at a
distance and provided with seal caps or copper
sheath with Gc 1/2 connection.
• Sensitive element with stainless steel diaphragm.
• Copper bulb and capillary, tinned for type C04C
and C04D.
• Base, cover and knob in shock-proof
self-extinguishing thermoplastic V0.
• Compliance with standards CEI EN 60947-5-1.
• IP65 waterproof execution C04..Y.
THERMOSTATS
TEMPERATURE CONTROLS
THERMOSTAT WITH CAPILLARY AND BULB FOR REMOTE MOUNTING
POSITIVE SAFETLY SHUTDOWN IMMERSION THERMOSTAT
POSITIVE SAFETY SHUTDOWN AND REGULATION IMMERSION BITHERMOSTAT, FOR DIRECT MOUNTING
SPECIFICATIONS
RANGE DIFFERENTIAL * CALIBRATION
ACCURACY
ADMISSIBLE
THERMOSTAT BODY
TEMPERATURE •
MAXIMUM BULB
TEMPERATURE
CAPILLARY
LENGTH
PROTECTION
LEVEL
C04A2 10 to 90°C 6 ± 1 K ±3°C -35 to 120°C 150°C 1 mt IP40
C04B2 50 to 300°C 8 ± 2 K ±3°C -35 to 120°C 310°C 1,5 mt IP40
C04C2 -20 to 40°C 2 ± 0,5 K ±2°C -35 to 60°C 80°C 1,5 mt IP40
C04D2 -35 to 20°C 2 ± 0,5 K ±2°C -35 to 50°C 80°C 1,5 mt IP40
C04E2 40 to 120°C 6 ± 2 K ±3°C -35 to 120°C 150°C 1 mt IP40
* The differential is subtracted from the Range value. The differential values refer to a thermal gradient of 1K/hour in liquid and 5K/hour in air.
• The storage and transport temperature corresponds to the thermostat body admissible temperature.
SPECIFICATIONS
CUT-OFF
ACTION
CUT-OFF
TOLERANCE
ADMISSIBLE THERMOSTAT BODY
TEMPERATURE •
MAXIMUM BULB
TEMPERATURE
PROTECTION LEVEL
C06A2M 100°C ±0 / - 6°C -35 to 120°C 130°C IP40
C06B2M 90°C ±0 / - 6°C -35 to 120°C 130°C IP40
• The storage and transport temperature corresponds to the thermostat body admissible temperature.
SPECIFICATIONS
CUT-OFF
ACTION
DIFFERENTIAL * CUT-OFF
TOLERANCE
ADMISSIBLE THERMOSTAT BODY
TEMPERATURE •
MAXIMUM BULB
TEMPERATURE
PROTECTION
LEVEL
C06A2M 10 to 90°C 8 K ±0 / - 6°C -35 to 120°C 130°C IP40
* The differential is subtracted from the Range value. The differential values refer to a thermal gradient of 1K/hour.
• The storage and transport temperature corresponds to the thermostat body admissible temperature.
ELECTRIC SPECIFICATIONS
Rated Insulation Voltage Ui 380V~
Continuious Duty Rated Current Ith 15A
Rated Operating Current ie: 220V~ 250V~ 380V~
Resistive Load AC-12 — 10A 10A
Inductive Load AC-15 — 2.5A 1.5A
Direct Current DC-13 0.2A — —
• Liquid expansion operation.
• Direct immersion mounting of the bulb via
threaded sheath Gc 1/2 (included).
• Sensitive element with stainless steel diaphragm.
• Copper bulb and capillary.
• Copper sheath with Gc 1/2PN10 connection
• Base and cover in shock-proof
self-extinguishing thermoplastic V0.
• I.S.P.E.L approval for C06A2M.
• Compliance with standards CEI EN 60947-5-1.
• Compliance with the requirements
established in chapter R.3.B. of the applicative
technical specifications of Ministerial Decree
1 December 1975.
• Liquid expansion operation.
• Direct immersion mounting of the bulb via
threaded sheath Gc 1/2 (included).
• The bi-thermostat is composed of a C03A and
a C06AM in a single cover and one sheath.
• Sensitive element with stainless steel diaphragm.
• Copper bulb and capillary.
• Copper sheath with Gc 1/2PN10 connection.
• Base and cover in shock-proof
self-extinguishing thermoplastic V0.
• I.S.P.E.L approval.
• Compliance with standards CEI EN 60947-5-1.
• Compliance with the requirements
established in chapter R.3.B. of the applicative
technical specifications of Ministerial Decree
1 December 1975.
ELECTRIC SPECIFICATIONS
Rated Insulation Voltage Ui 380V~
Continuious Duty Rated Current Ith 15A
Rated Operating Current ie: 220V~ 250V~ 380V~
Resistive Load AC-12 — 10A 10A
Inductive Load AC-15 — 2.5A 1.5A
Direct Current DC-13 0.2A — —
ELECTRIC SPECIFICATIONS
Rated Insulation Voltage Ui 380V~
Continuious Duty Rated Current Ith 15A
Rated Operating Current ie: 220V~ 250V~ 380V~
Resistive Load AC-12 — 10A 10A
Inductive Load AC-15 — 2.5A 1.5A
Direct Current DC-13 0.2A — —
105
ADJUSTABLE THERMOSTAT
THERMOSTATS
TR2
OVERALL DIMENSIONS
Thermostat single pole liquid filled sensing bulb and bellows, operating
switch contacts for the automatic adjustment of the temperture of boilers,
electric, radiators, overns, washing machines, dish washers, etc, besides
different applications in the field of home and industrial air conditioning
and house hold appliances. Sensing bulb may be supplied with pocket
or gland for liquid sealing.
TECHNICAL DATA
CONTACTS Ag 1000/1000
CONTACTS RATING15 (2.5)A 250V~
10 A 380V~
CUT-OFF CONTACTS FOR TEMPERATURE RAISING
OR SWITCHING CONTACT–––
MAX. HEAD TEMPERATURE 150°C
CAPILLARY LENGTH 1000 mm
MIN. CAPILLARY BENDING RADIUS 5 mm
NOISE LEVEL VDE cl. N
NUMBER OF AUTOMATIC CYCLES ll (100 000)
TEMPERATURE RATE OF CHANGE 1°K/min
RESISTANCE TO TRACKING PTI 250 (KB 250)
STANDARD TYPES
CODE TEMP. RANGE TEMP. DIFFERENTIAL MAX. BULB TEMP. COPPER BULB CAPILLARY LENGTH AG/CD CONTACTS
540043 -30°C/+35°C Δt = 1,5° ± 0,5°K 65°C ø6 x 215 mm —
540030 0°C/40°C Δt = 2° ± 1°K 65°C ø9,5 x 95 mm —
540010 0°C/90°C Δt = 4° ± 1°K 150°C ø6,5 x 95 mm —
540168 0°C/120°C Δt = 4° ± 1°K 150°C ø6,5 x 95 mm —
540140 0°C/210°C Δt = 9° ± 2°K 270°C ø5 x 136 mm —
540020 0°C/300°C Δt = 10° ± 2°K 350°C ø3,5 x 195 mm —
541307 0°C/90°C Δt = 4° ± 1°K 150°C ø6,5 x 95 mm 1500 mm
540080 17,5°C/30,5°C Δt = 1,5° ± 0,5°K 65°C ø6,5 x 210 mm — Ag/Cd
106
THERMOSTATS
THERMOSTAT FOR PANEL MOUNTING SERIES KMf-70; KMf-20
THERMOSTAT, M/R ADJUSTABLE
THERMOSTAT, M/R ADJUSTABLE
DETAILSPROTECTION IP 00
ARRANGEMENT TO DIN 3440 as
STB = Safety Temperature Limiter
STW (STB) = Safety Temperature Monitor
DVGW Approved to EU Gas Appliances Directive (90/386/EWG)
DESCRIPTIONThe panel-mounting thermostats Type KMf are suitable for controlling
and monitoring heating systems, boilers, heat exchangers and pumps
in heating, ventilating and air conditioning. The panel-mounting
thermostats are approved to DIN 3440.
The essential information for ordering is shown in the Technical data
with a grey background.
GERNERAL APPLICATION• Ovens and Furnances
• Laboratory and Climatic Cabinets
• Apparatus and Mechanicial Equipment
• Heating Boilers to DIN 4751
• Steam Boilers to DIN 4754
• Indirect Heating Systems to DIN 4754
OPERATING PRINCIPLEThe panel-mounting thermostats Type KM operates on the principle
of liquid expansion. A temperature change in a liquid-filled sensing
system, consisting of probe, capillary and expansion capsules,
produces a volumechange. The resulting movement of the diaphragm
acts through a mechanism to operate the microswitch.
TECHNICAL DESCRIPTIONSAFETY TEMPERATURE LIMITER STB AND SAFETY
TEMPERATURE MONITOR STW (STB) FAIL-SAFE
Failure of the measuring system, i.e. leakage of the expansion liquid,
causes the pressure under the diaphragm of the STB; STW (STB)
to drop, thus permanently opening the circuit, terminals 1-2.
Reset is no longer possible.
If the prode is cooled down to a temperature below - 10°C the
circuit, temperature 1-2 is also opened; as the temperature rises
above -10°C the STB has to be reset manually by pressing the reset
button. On the STW (STB) the circuit is re-closed automatically.
LOCK-OUT FUNCTION
On the STB, exceeding the set temperature limit causesthe circuit,
terminals 1 – 2, to be opened and locked out mechanically. After the
temperature has dropped by about 10% of span below the setpoint
the microswitch can be reset manually.
When using the STW (STB) monitor as STB limiter, the lock-out
function to DIN 440 has to be provided by a subsequent circuit.
The circuit must conform to Section 8.7 of DIN/VDE 0 118.
SETPOINT ADJUSTMENT
The setpoint can be adjusted before installation by rotating the
setting spindle with a screwdriver.
STANDARD ACCESSORYOperating Instructions B 60.2045.
TECHNICAL DATA
CASE Steel, Zinc-plated, Heat-resistant Plastic
CASE FIXING 2 Screws, M4, Spacing 28mm
SWITCH
Type KMf-70
Normally
Single-pole n.c. (break) contact opening on temperature rise - Code O
At extra charge Single-pole changeover contact Code U
Type KMf-20 Single-pole changeover contact U
SWITCHING DIFFERENTIAL IN % OF SPAN 9 +2/-3
RATING
STW (STB), STB
16 A 380 V AC
16 (2)A 250 V AC, p.f. = 1 (0.6)
0.25 A 250 V DC
STB, CODE 70/U
on n.c. (break) contact
16 A 380 V AC
16 (2)A 250 V AC, p.f. = 1 (0.6)
0.25 A 250 V DC
on n.c. (make) contact
2 A 380 V AC
2 (1)A 250 V AC, p.f. = 1 (0.6)
0.25 A 250 V DC
STB CODE 70/AU0.1 A 24 V AC/DC
contact resistance 2.5-10mΩ
107
THERMOSTATS
THERMOSTAT FOR PANEL MOUNTING SERIES KMf-70; KMf-20
THERMOSTAT, M/R ADJUSTABLE
TECHNICAL DATA
ELECTRICAL CONNECTIONSNormally faston tabs A 6.3 x 0.8mm, DIN 46 244
Code X - Screw terminals up to 2.5mm² conductor cross-section
SWITCHING POINT ACCURACY(based on setpoint) in upper third of scale range +0/-5% span. Switching
point accuracy can be shifted to a different scale range to special order.
PERMITTED AMBIENT TEMPERATURE
AT THERMOSTAT HEAD AND CAPILLARY
DURING OPERATION
Maximum +80°C
Minimum -40°C for full-scale below 200°C
-20°C for full-scale 200°C to 350°C
PERMITTED STORAGE TEMPERATURE
THERMOSTAT HEAD, CAPILLARY
AND PROBE
Maximum +50°C
Minimum -50°C
PROTECTION IP00 to DIN 60 529
SCALE SPAN 250° L
OPERATING POSITION Unrestricted
WEIGHT O.3
DIN APRROVAL NO.KMf-20 STW (STB) 82294 S
KMf-20 STB 82494
DVGW APPROVAL NO. CE-0085 AR 0125
PROBE TABLE
KMf-70; KMf-20 PROBE MATERIAL COPPER (STAINLESS STEEL*)
SETPOINT RANGE °CMAX. PROBE
TEMPERATURE °C
PROBE LENGTH DIM. "L" IN mm FOR "d" PROBE DIAMETER. 6mm DIA. IS STANTARD
5 6 7 8
0 + 50 60 235 163 126 104
0 + 100 115 133 98 80 70
+ 30 + 110 130 159 115 92 79
+ 20 + 120 140 131 97 79 70
+ 60 + 130 150 175 125 99 84
+ 20 + 150 175 108 82 69 62
+ 50 + 200 230 114 83 67 59
+ 50 + 250 ** 290 90 67 56 51
+ 50 + 300 ** 345 74 57 49 45
MM INCH MM INCH MM INCH
0.8 0.031 60 2.36 125
1.5 0.06 62 2.44 126
5 0.20 67 2.64 131
6 0.24 69 2.72 133
6.3 0.25 70 2.76 159
7 0.28 74 2.91 163
8 0.31 79 3.11 175
10.5 0.41 80 3.15 235
15 0.59 82 3.23
20 0.79 83 3.27 2.5 m² 0.004 in²
28 1.10 84 3.31 1 m 3.3 ft
39 1.54 90 3.54 2 m 6.7 ft
42 1.65 92 3.62 3 m 10 ft
45 1.77 97 3.82 5 m 16.7 ft
48 1.89 98 3.86
49 1.93 99 3.90
51 2.01 104 4.09
56 2.20 108 4.25
57 2.24 114 4.49
59 2.32 115 4.53
108
THERMOSTATS
DTP-0071-4
109
THERMOSTATS
OPERATING TEMPERATURE CHARACTERISTICS
C
PCOLD NORMAL WARM - - -
ON (5.0) (5.0) 5.0 ± 1.3 - - -
OFF (-10.0) (-6.0) - 2.0 ± 1.3 - - -
OFF - - - - - - - - - - - -
1. Formal Operating Temperature Characteristics are based on second operating.
2. ( )... Reference Value.
3. Capillary Tube should be so installed that minimum 150mm, tube end can sense the controlled temperature.
ELECTRICAL RATING
RATED VOLTAGE (V)
(A) RATED AMPS
POWER FACTOR AC
COSø 125V 250V
NON-INDUCTIVE CURRENT C
|
L
1 1~8 0.5~4
INDUCTIVE CURRENTF.L.A 0.75 1~6 0.5~3
F.L.A 0.45 1~24 0.5~12
NON-INDUCTIVE CURRENT C
|
H
1 - - - - - -
INDUCTIVE CURRENTF.L.A 0.75 - - - - - -
F.L.A 0.45 - - - - - -
TYPE
TYPE OF CONTACT (S.P.S.T.) ARROW MARK INDICATES TEMP. RISE
CONTACT RESISTANCE Less than 50mΩ
INSULATION RESISTANCE More than 100MΩ at DC 500V Megger
DIELECTRIC STRENGTH Withstand AC 1500V for one minute.
TEMPERATURE CONDITION
IN ACTUAL USE
TS > TB Ts : Ambient Temperature at Switch Body
TB : Ambient Temperature at Sensing Bulb
CHARGE G – Charge
FOLLOW UP CHARACTERISTICS
OF SENSING BLUB
Controlled Fluid : Liquid
Temperature Change Rate : More than 1°C / 1 min
MAX. ALLOWABLE TEMPERATURESwitch Body : 70°C
Sensing Bulb : 80°C
MOUNTING OF SENSING BULB In any position
CONTACT LIFE 200,000 Cycles
NOTE 1. Cam-Shaft rotating torque cold~warm = 0.2~3.5 Kgf - cm
DTP-0071-4
110
THERMOSTATS
THERMOSTATS REFRIGERATOR
ATB-X1G3, REFRIGERATORS
111
THERMOSTATS
THERMOSTATS REFRIGERATOR
OPERATING TEMPERATURE CHARACTERISTICS
C
PCOLD NORMAL WARM - - -
ON (-10) - 2 ± 1.5 (8) - - -
OFF (-20) - 10.5 ± 1.5 (1.5) - - -
OFF - - - - - - - - - - - -
1. Formal Operating Temperature Characteristics are based on second operating.
2. ( )... Reference Value.
3. Capillary Tube should be so installed that minimum 150mm, tube end can sense the controlled temperature.
ELECTRICAL RATING
RATED VOLTAGE (V)
(A) RATED AMPS
POWER FACTOR AC
COSø 125V 250V
NON-INDUCTIVE CURRENT
INDUCTIVE CURRENTF.L.A 0.75 1~6 0.5~3
F.L.A 0.45 1~24 0.5~12
TYPE
TYPE OF CONTACT (S.P.S.T.) ARROW MARK INDICATES TEMP. RISE
CONTACT RESISTANCE Less than 50mΩ
INSULATION RESISTANCE More than 100MΩ at DC 500V Megger.
DIELECTRIC STRENGTH Withstand AC 1500V for one minute.
TEMPERATURE CONDITION IN
ACTUAL USE.
TS > TB Ts : Ambient Temperature at Switch Body
TB : Ambient Temperature at Sensing Bulb
CHARGE G – Charge
FOLLOW UP CHARACTERISTICS OF
SENSING BLUB
Controlled Fluid : Liquid
Temperature Change Rate : More than 1°C / 1 min
MAX. ALLOWABLE TEMPERATURESwitch Body : 70°C
Sensing Bulb : 80°C
MOUNTING OF SENSING BULB In any position
CONTACT LIFE 200,000 Cycles
CAM ROTATING TORQUE 1. Cam-Shaft rotating torque cold~warm = 0.2~3.5 Kgf - cm warm~off = 0.2~4.5 Kgf - cm
112
2-WIRE IN-HEAD TEMPERATURE TRANSMITTER
TEMPERATURE TRANSMITTERS
2-WIRE IN-HEAD TEMPERATURE TRANSMITTER
2-WIRE IN-HEAD TEMPERATURE TRANSMITTER
The 2-Wire In-Head Temperature Transmitter is based on Microprocessor with flexibility for accepting
the signal mV, Pt100 and variety of Thermocouples. It delivers a scalable linear 4~20mA output current
proportional to the sensor temperature. Available option for a user-friendly configuration software is
provdided for parameter setup including sensor type, temperature range, filter ... etc.
SPECIFICATIONS
SENSOR INPUT TYPE – DESCRIPTION ACCURACY (MAX. RANGE)
THERMOCOUPLEType J / K / R / S / T / N / E According to IEC60584
(ITS-90). Impedance : 1MΩ< 0.3%
Pt1002 or 3-Wire connection (Connect terminal 2 & 3
for 2-Wire Sensor), Excitation 180μA =0.00385
according to IEC 60751 (ITS-90)
0.2%
VOLTAGE 0 ~ 50mVdc, Impedance: 1MΩ 0.2%
RESPONSE TIME < 100ms
OUTPUT 2-Wire 4~20mA, linear with respect to the measured
temperature
RESOLUTION 0.004mA (12 bits)
POWER SUPPLY 12~35 VDC across the transmitter
MAX. LOAD (RL) RL (max) = (VDC-12) / 0.02 [Ω]
OPERATION TEMPERATURE & HUMIDITY -40 to 85°C , 0 to 90% RH
ELECTROMAGNETIC COMPATIBILITY EN 50081-2, EN 50082-2
HOUSING ABS Plastic (Dimension: Dia. 44m x Height 25mm)
NOTE No isolation between the sensor and the 4~20mA loop. Internal protection against polarity inversion, cold junction
compensation for the thermocouple.
SPECIFICATION
ACCURACY ±0.1% FS (At 23ºC)
INPUT RANGE -100 ~ 600ºC
OUTPUT 4 – 20mA, Linear with respect to the
measured temperature
POWER SUPPLY 10 ~ 30VDC
MAX. LOAD (RL) RL (max) = (VDC-10) X 50 [Ω]
LIMITED OUTPUT CURRENT Under 25mA
TEMP. COEFFICIENT ±0.02% / ºC
OPERATION TEMPERATURE & HUMIDITY -5 to 70ºC, 0 to 90% RH
SPAN ADJUSTMENT
1 30 ~ 60ºC
2 80 ~ 160ºC
3 150 ~ 300ºC
4 200 ~ 400ºC
5 300 ~ 600ºC
S Specified
WIRING DIAGRAM
WITH LED INDICATION AND DC
POWER POLARITY PROTECTION
ZERO ADJUSTMENT Standard is 0ºC
113
VALVES
VALVES
2- AND 3- WAY MOTORIZED BALL VALVE
3- WAY MOTORIZED GLOBE VALVE
AIR FLOW SWITCH
• To control the flow rate of water, with equal percentage feature, in ventilation,
air-conditioning and heating systems.
• Ball valves are operated by a rotary servo control with two way rotation.
• To control the flow rate of water, with equal
percentage feature, in ventilation, air-conditioning
and heating systems.
• Globe valves are operated by a linear servo control.
• Suitable for signalling, controlling and regulating
the air flow in air conditioning systems; to
control fans, compressors, etc.
• Case in shock-proof plastic with
self-retaining screws
• AISI 301 stainless steel flexible blade
(50 x 165mm)
• Electric connections on Faston 6.3 (provided)
• Calibration screw for adjusting the cut-in point
• PVC flange, 5mm thick
• Compliance with standards CEI EN 60730-1
• SPDT single-pole switching microswitch
ELECTRIC SPECIFICATIONSRATED INSULATION VOLTAGE Ui 380V-
CONTINUOUS DUTY RATED CURRENT Ith 10A
RATED OPERATING CURRENT IE 220V- 250V-
RESISTIVE LOAD AC-12 10A
INDUCTIVE LOAD AC-15 3A
DIRECT CURRENT DC-13 0,2A
2 WAY
DN
mm
FEMALE
THREADED
FITTING
KV
m³/h
PRESSURE
RATED
BAR
DIFF.
BAR
Z20L 15 1/2" 4 16 3,5
Z20M 20 3/4" 6,3 16 3,5
Z20A 25 1" 10 16 3,5
Z20B 32 1" 1/4 16 16 3,5
Z20C 40 1" 1/2 25 16 3,5
Z20D 50 2" 40 16 3,5
2 WAY
DN
mm
FEMALE
THREADED
FITTING
KV
m³/h
PRESSURE
RATED
BAR
DIFF.
BAR
ZL30A 15 G1" 4 16 4
ZL30B 20 G1" 1/4 6.3 16 4
ZL30C 25 G1" 1/2 10 13 4
ZL30D 32 G2" 16 8 4
ZL30E 40 G2" 1/4 25 4,9 4
ZL30F 50 G2" 1/2 40 3 3
3 WAY
DN
mm
FEMALE
THREADED
FITTING
KV
m³/h
PRESSURE
RATED
BAR
DIFF.
BAR
Z30L 15 1/2" 4 16 3,5
Z30M 20 3/4" 6,3 16 3,5
Z30A 25 1" 10 16 3,5
Z30B 32 1" 1/4 16 16 3,5
Z30C 40 1" 1/2 25 16 3,5
Z30D 50 2" 40 16 3,5
3 WAY WITH FLANGE
DN
mm
KV
m³/h
PRESSURE
RATED
BAR
DIFF.
BAR
ZL31A 25 10 13 4
ZL31B 32 16 8 4
ZL31C 40 25 4,9 4
ZL31D 50 40 3 3
ZL31E 65 63 4 4
ZL31F 80 100 2,7 2,7
ZL31G 100 145 1,6 1,6
ZL31H 125 220 0,9 0,9
ZL31I 150 320 0,5 0,5
DETAILS
DUCT
SURFACE cm²
MAXIMUM IN-
CREASING FLOW
SPEED m/sec
MAXIMUM DE-
CREASING FLOW
SPEED m/sec
OPERATING
TEMPERATURE
MAXIMUM
AMBIENT
TEMPERATURE
PROTECTION
LEVEL
FF71A
160 1,4 0,6
-20 to 70 50°C IP54320 2,2 1,2
640 3 1,6
1280 3 1,7
Z20
Z30
ZL30
ZL31
114
SOLENOID VALVES
VALVES
DIRECT ACTING SOLENOID VALVE BODIES
SERVO-ASSISTED DIAPHRAGM NORMALLY CLOSED VALVE BODIES
• Solenoid valves suitable for water, air, fuel-oil, inert gases and other fluids non-corrosive for copper alloys, with viscosity up to 2° Engler2-way normally closed.
• Direct action• With the coil energized, the valve opens
immediately to allow fluid to pass.• Closing time 10 msec.• Stamped brass valve body.• Stainless steel internal parts (17%CR).• VITON seals (fluroelastomer).• Test Pressure PN (DIN 2401):25 bar• With coil in dc the pressure indicated
is reduced by 60%• Coils suppled separated from the body.
• Solenoid valves suitable for large flow capacity, suitable for water, air, fuel-oil, inert gases and other fluids non-corrosive for copper alloys, with viscosity up to 2° Engler
• 2-way normally closed• Indirect operation with servo-diaphragm blocked.• Minimum operating pressure between upstream
and downstream must be 0.1 bar• Stamped brass valve body• Stainless steel internal parts (17% CR)• NBR seals (BUNAN)
• With coil in dc the maximum pressure indicated in the table is reduced to 60%
• Coils supplied separated from the body• Closing time : 10 msec• Press-forged brass body• Internal parts in stainless steel (17% CR).• Gaskets in NBR (buna N)• With DC coil indicated pressure values must
be reduced to 60%.• Gasket in Viton available on request only
for sizes up to G1"
SPECIFICATIONS
ORIFICEDIAMETER
mm
FEMALE UNION
KVm³/h
MAXIMUM DIFFERENTIAL PRESSURE
TEST PRESSURE(DIN 2401)
PN BAR
OPERATING TEMPERATURE
Vn BAR 0.85Vn BAR
M20B3 3 G 1/4 0,27 16 10 25 -10 to 140
M20C5 5 G 3/8 0,612 6 2 25 -10 to 140
M20D5 5 G 1/2 0,612 6 2 25 -10 to 140
M20E7 7 G 3/4 1 2,5 1,8 25 -10 to 140
Kv = flow rate in m³/h of water with difference in downstream and upstream pressures of 1 bar (1 bar = 100 kPa)
For IM21 bi-frequency coils used at 60 Hz, the values indicated are reduced by an average of 12%.
SOLENOID VALVES with test certificates isssued by the Study and Experience Centre of the MINISTRY OF THE
INTERIOR Fire-Prevention Service Rome Capannelle.
SPECIFICATIONS
ORIFICEDIAMETER
mm
FEMALE UNION
KVm³/h
CLOSING TIME
DP DI OF 1 BAR
MINIMUM
OPERATING
PRESSURE
BAR
MAXIMUM
DIFFERENTIAL
PRESSURE
TEST PRESSURE (DIN2401) PN-BAR
M23C13 13 G 3/8 3 1 0,1 20 25
M23D13 13 G 1/2 3 1 0,1 20 25
M23E20 20 G 3/4 8,4 1,5 0,1 20 25
M23F25 25 G 1 9,6 1,5 0,1 20 25
M23G35 35 G 1 1/4 25,2 2,5 0,1 10 16
M23H40 40 G 1 1/2 30 3 0,1 10 16
M23I50 50 G 2 37,2 3,5 0,1 10 16
24V
CONTROL
COIL
110/115V230V CONNECTOR
ORIFICE mm
UNION KVm³/h
WORKINGPRESSURE
BAR
M20C5 IM21F IM21H IM21M 1578501 5 G 3/8 0,612 0 to 2
M20D5 IM21F IM21H IM21M 1578501 5 G 1/2 0,612 0 to 2
M20E7 IM21F IM21H IM21M 1578501 7 G 3/4 1 0 to 2
M20C51 IM22F – – 1578501 5 G 3/8 0,612 0 to 2
M20D51 IM22F – – 1578501 5 G 1/2 0,612 0 to 2
M20E71 IM22F – – 1578501 7 G 3/4 1 0 to 2
115
REFRIGERATION SOLENOID VALVES
SERIES 68 AD
FUILD CONTROL COMPONENTS
SPECIFICATIONS
ATTACCHI PIPES
IN -> OUT
Ø
MM
CODE KV
M³/H
M.O.P.D.
BAR
DIMENSIONS
MM
WEIGHT
KG
AC DC A B C D
ODF 6MM 2,5 6806 0,170 25 17 111 67 47 50 0,220
ODF 1/4" 2,5 6807 0,170 25 17 111 67 47 50 0,220
ODF 10 MM 3,0 6810 0,230 25 17 116 78 60 59 0,360
ODF 3/8" 3,0 6811 0,230 25 17 116 78 60 59 0,360
1/4" SAE – UNF
7/16"2,5 6812 0,170 25 17 65 67 47 50 0,220
3/8" SAE – UNF
5/8"3,0 6813 0,230 25 17 71 78 60 59 0,395
ODF 6MM 2,5 6825 0,170 25 17 105 136 47 49 0,210
ELECTRICAL INFORMATION
POWER
6806-07-12-25 6810-11-13
HOLDING IN RUSH HOLDING IN RUSH
V~ 12 24 49 110 230 400 50 60 Hz 17, 5VA 28VA 23VA 33VA
V= 12 24 48 110 16W 21W
FOR CONSTRUCTION DETAILS OF THE COILS SEE CHAPTER " PROJECT INFORMATION"
MAX. TEMPERATURE
FLUIDS AMBIENT
PTFE NEOPRENE- 30 + 80°C
-45 + 125°C -35 + 100°C
PRESSURE LOSS DIAGRAMDetailed information on the flow rate
capacity for the various "refrigeration
fluids" are available under chapter
"Project Information".
DIAGRAM
1 Dado Lock Nut
2 Rondella Washer
3 Bobina Coil
4 Nucleo Fisso Tube Top
5 Molla Spring
6 Nucleo Mobile Plunger
7 Piattello Support
8 Pastiglia Seat
9 Rondella Washer
10 Corpo Valve Body Base
RICAMBI SPARE PARTS
A Bombina Coil
6806 6810 6812 6813 6825
116
REFRIGERATION SOLENOID VALVES
SERIES 68 AD
SOLENOID VALVE DIRECT ACTING 2/2 WAY N.C.
GENERAL FEATURES
MINIMUM WORKING PRESSURE 0 BAR
PARTS IN CONTACT WITH THE FLUID
SEALING PTFE
BODY Brass
INTERNAL PARTS Stainless Steel
FLUIDSAll type of Refrigerant fluids except
Ammonia (NH³)
ONE WAY DIRECTION VALVE
NON-SEVICEABLE VALVE
VALVE SUPPLIED WITH
- Three pole plug connector UNI ISO 4400
(DIN 43650A) - IP 65
- Screw and mounting bracket.
(Except for Series 6825)
MOUNTING POSITION
Any to obtain the best performances
the valves has to be installed with the
coil vertical; the position with the coil
downwards is not recommended.
AMBIENT TEMPERATURE
- 30°C + 80°C, in D.C. for temperatures
higher than 40°C, the performances
(M.O.P.D.) could decrease.
SPECIAL EXECUTIONS Sealing in Neoprene (6806-6812)
ACCESSORIESNut and gasket to aid against humidity for
the coil SAE nut for copper tube connection.
C®
117
FUILD CONTROL COMPONENTS
SPECIFICATIONS
ATTACCHI PIPES
IN -> OUT
Ø
MM
CODE KV
M³/H
M.O.P.D.
BAR
DIMENSIONS
MM
WEIGHT
KG
AC DC A B C D
3/8" SAE – UNF
5/8"8 6853 1,300 28 17 84 91.5 60 73.5 0.520
1/2" SAE – UNF
3/4"10 6854 1,600 28 17 84 91.5 60 73.5 0.520
ODF 10 mm 8 6851 1,300 28 17 118 91.5 60 73.5 0.460
ODF 12 mm 10 6862 1,600 28 17 118 91.5 60 73.5 0.460
ODF 3/8" 8 6863 1,300 28 17 118 91.5 60 73.5 0.460
ODF 1/2" 10 6864 1,600 28 17 118 91.5 60 73.5 0.460
ELECTRICAL INFORMATION
POWER
6806-07-12-25
HOLDING IN RUSH
V~ 12 24 49 110 230 400 50 60 Hz 30VA 33VA
V= 12 24 48 110 20W
FOR CONSTRUCTION DETAILS OF THE COILS SEE CHAPTER " PROJECT INFORMATION"
MAX. TEMPERATURE
FLUIDS AMBIENT
PTFE- 30 + 80°C
-45 + 125°C
REFRIGERATION SOLENOID VALVES
SERIES 68 SC
1 Dado Lock Nut
2 Rondella Washer
3 Bobina Coil
4 Nucleo Fisso Tube Top
5 O-Ring O-Ring
6 Molla Spring
7 Nucleo Mobile Plunger
8 Pistiglia Seat
9 Fascia Elastica Piston Rings
10 Otturatore Shutter
11 Corpo Valve Body Base
RICAMBI SPARE PARTS
A Bombina Coil
B Cannotto Tube Guid
C Nudeo Mobile Plunger
D Otturatore Shutter
C®
6853 6854 6861 6862
118
SOLENOID VALVE DIRECT ACTING 2/2 WAY N.C.
GENERAL FEATURES
MINIMUM WORKING PRESSURE 0,1 BAR
PARTS IN CONTACT WITH THE FLUID
SEALING PTFE
BODY Brass
INTERNAL PARTS Stainless Steel
FLUIDSAll type of Refrigerant fluids except
Ammonia (NH³)
ONE WAY DIRECTION VALVE
NON-SEVICEABLE VALVE
VALVE SUPPLIED WITH
- Three pole plug connector UNI ISO 4400
(DIN 43650A) - IP 65
- Screw and mounting bracket.
(Except for Series 6825)
MOUNTING POSITION
Any to obtain the best performances
the valves has to be installed with the
coil vertical; the position with the coil
downwards is not recommended.
AMBIENT TEMPERATURE
- 30°C + 80°C, in D.C. for temperatures
higher than 40°C, the performances
(M.O.P.D.) could decrease.
SPECIAL EXECUTIONS Sealing in Neoprene (6806-6812)
ACCESSORIES
A special coil B20 (30W) is available
to increase performances (M.O.P.D.) in
D.C. SAE nut for copper tube connection.
Nut and Gasket to aid against humidity
for the coil.
REFRIGERATION SOLENOID VALVES
SERIES 68 SC
C®
119
Let us put you in ControlLet us put you in Control
OFFICE52 TUNGARRA ROAD GIRRAWEEN NSW 2145 AUSTRALIA
PO BOX 337 TOONGABBIENSW 2146 AUSTRALIA
TEL (02) 9896 4512FAX (02) 9896 [email protected]