Catalog About Probe

Embed Size (px)

Citation preview

  • 8/12/2019 Catalog About Probe

    1/42

    About the Company

    Staveley Instruments is a US manufacturing company based in Kennewick, Washingtonproducing a wide range of innovative NDT equipment and sensors. The company manufactures

    all the top names in NDT such as Nortec, Sonic, CPX-160 X-Ray and of course Nortec eddycurrent probes and Harisonic ultrasonic transducers. The latest technology is reflected in eachproduct we produce, including the new PowerLink technology, which allows specialprogramming features to be included on each probe and recalled when used with NortecPowerLinkcompatible instruments.

    Our products contribute to quality control and preventive maintenance which leads to costreduction, improved material utilization and better overall results for our many customersthroughout the world.

    As part of a family of companies within Staveley NDT Technologies, we have connectionsthroughout the world making us one of the largest NDT companies with global representation.

    Staveley Instruments has representation throughout Europe and the United Kingdom, parts ofAfrica and the Far East including Japan and China, Australia and New Zealand as well as theUS, Canada and Mexico.

    With this international experience, Staveley Instruments has become more responsive and betterable to meet the future challenges in NDT applications and the problems that you face today withtesting, measurement and quality assurance.

    Application Engineering Support

    At Staveley Instruments we have engineering staff and application engineers on hand to assistyou with all your NDT applications.

    We also have a dedicated staff of Eddy Current Probe and Ultrasonic Transducer engineers tohelp you with all your sensor requirements, particularly if you require a product that must bespecially engineered to your application.

    Representation

    Staveley Instruments is represented by a well trained team of experienced technicalrepresentatives, most of whom work directly for Staveley Instruments. Each representative isqualified to demonstrate our complete range of products, and assist customers with their

    application needs by helping them to select correct solutions.

    Page 1Rev 2.2Rev 2.5

  • 8/12/2019 Catalog About Probe

    2/42

    Contents

    Page: Description:1 About the company2 Contents3 Eddy Current probe selection4 Eddy Current probe design5 Eddy Current probe design (cont.)6 PowerLink probes7 Rotating Scanner Probes (SPO-5965 series)8 Rotating Scanner Probes (SPO-5393 series)9 Rotating Scanner Probes (RA PROBE series)10 Rotating Scanner Probes (SPO-3564 series)11 Rotating Scanner Probes (SPECIAL PROBES)12 Rotating Scanner Probes (SPECIAL PROBES) cont.13 Rotating Scanner Probes (PS5 series)14 Rotating Scanner Probe Kits for PS5 Scanner15 Rotating Scanner Probes (PS2/PS3 series)16 Rotating Scanner Probes (RC series)17 Rotating Scanner Probes (SNC/SCR series probes for the PS-4

    scanner)18 Rotating Scanner probe kits19 Bolt hole probes- standard detachable (B series)20 Bolt hole probes PowerLink detachable (BL series)21 Pencil probes- standard (3551 series)22 Pencil probes- PowerLink (3551L series)23 Pencil probes-standard detachable (P series)24 Pencil probes-PowerLink detachable (PL series)25 Metal shaft probes-standard detachable (P series)26 Metal shaft probes-PowerLink detachable (ML series)27 Surface probes-standard detachable (S series)28 Surface probes-PowerLink detachable (SL series)29 Ring/Donut probes-standard (SPO series)30 Ring/Donut probes-PowerLink (SPO L series )31 Ring/Donut probes-standard detachable (R and RR series)32 Ring/Donut probes-PowerLink detachable (RL and RRL series)33 Sliding probes-standard detachable34 Sliding probes-PowerLink detachable35 Conductivity probes-standard36 Conductivity probes- PowerLink37 ID probes38 OD probes39 General purpose kits40 Documentation41 Special Product Requests

    ProbeCompatibility

    Each page contains figuressimilar to those above.This represents which

    instruments the probes areprimarily designed for.

    Nortec 3000

    Nortec 1000 Series

    Nortec 24

    Nortec 19eII

    Page 2 Rev 2.2Rev 2.5

    WorkStation

    PowerStation

    Nortec Eddy Current Probes

  • 8/12/2019 Catalog About Probe

    3/42

  • 8/12/2019 Catalog About Probe

    4/42

    Eddy Current Probe Design

    Standard Probe designs

    Cost, uniformity and availability make it desirable to use standard probes whenever possible. Many

    standard designs, with various frequencies, diameters and detection circuits are listed in this catalog.

    Primary applications for standard probes:

    Surface probes- are used for discovering flaws both on and below surfaces. Available in a broadfrequency range, their diameters are usually large for accommodating lower frequencies or scanning largeareas.

    Pencil probes-have smaller diameter housing coils built for higher frequencies. Applications are usuallylimited to surface flaws because of higher frequency.

    Right Angle Pencil Probes- reach areas inaccessible to pencil probes. They normally employ the samecoils and frequencies as pencil probes.

    Hand Held Bolt Hole Probes-have coils located at right angles to the probe direction, and are rotated byhand with the fastener removed. Standard and custom diameters are available with absolute anddifferential coils.

    Scanner Driven Bolt Hole Probes- are used with mechanical devices for automatically rotating andIndexing into hole. Absolute and differential coils are common at higher frequencies of 500 kHz and2 MHz. They bear close tolerances and are highly reliable.

    Donut Probes-are designed to inspect aircraft fastener holes with fasteners in place, and can be used onuneven fastener holes. Various inside/outside diameters and frequencies for different size fasteners anddiffering materials are available.

    Sliding Probes-are designed to inspect aircraft fastener holes with fasteners in place, at higher scanrates than donut probes. Common sizes and frequencies using the reflection coil techniques are oftenapplied in major airframe inspection requirements.

    ID Probes- usually have a frequency range of 5 kHz to 100 kHz made in absolute or differentialconfigurations. Many body styles are available depending on the inside surfaces of tubes to be inspected.Most probe diameters are made to meet customers' requirements.

    OD Probes- are usually designed for a frequency range of 5 kHz to 100 kHz and available in absolute,differential and switchable configurations. Tubes to be inspected are passed through the coil for absoluteor differential flaw detection at high speeds.

    Page 4 Rev 2.2Rev 2.5

    Table Of ContentsMain Index

  • 8/12/2019 Catalog About Probe

    5/42

    Eddy Current Probe Design

    Special Probe designs*

    Probes are designed to meet customers' special requirements. The accuracy of a design is tested by

    placing a test coil over a defect through matching surfaces of the part and the EC probe.

    Special configurations are used in many applications. The broadest range is employed in the inspectionof aircraft engines and airframes. These are developed in cooperation with the customer and StaveleyInstruments' designers.

    Custom development is done routinely at Staveley Instruments. More than thirty years of experience insolving difficult problems maximizes the performance of instrument and probe. Our understanding ofImpedance Plane Analysis and the performance of certain EC components, are a guide to expectedresults shown on an EC instrument like the Nortec 2000. Impedance changes (Z=X+R) are directresults of changes in the inductive reactance or resistance of the EC field induced into a part. Both phaseand amplitude changes are viewable on the instrument screen.

    Coil configurations, diameter and frequency effect sensitivity, but calibration standards are also importantto the success of the EC test. Calibration standards are usually based upon the material to be inspectedcontaining known notches of minimum size for detection. These notches are made by EDM processingfor best results, but a narrow saw cut is adequate in certain situations. Conductivity measurements canbe certified to N.I.S.T.

    * See last page cover for more information.

    Page 5Rev 2.2Rev 2.5

    Table Of ContentsMain Index

  • 8/12/2019 Catalog About Probe

    6/42

    PowerLink Technology

    Nortecprobes have always set the standard for Performance, Repeatability and Quality. The newgeneration of NortecPowerLink Technology Sensors continue to build on its reputation, now providingan additional Value Added capability when used on Staveley Instruments new line of eddy current

    instruments.

    PowerLink Eddy Current Probes feature:

    Automatic probe setup including frequency, gain, filters, horizontal and vertical position, and alarmgates*.

    Common cable configuration allows both bridge and reflection probes to be operated with the samecable.

    Provides probe model number, serial number, screen data and space for comments on printout fromStaveleys new eddy current instruments.

    Probes are backward compatible with earlier versions of Nortecinstruments, such as the NDT-19eand NDT-24, with the appropriate cable.

    Probes are capable of being reprogrammed as the need arises. PowerLink can be bypassed to allow the probe to be used for any applicable test. Level III programming (user programmable) supported in the Nortec WorkStation and PowerStation

    instrumentation.

    *Any command featured in the instrument documentaion may be programmed into the Nortec PowerLink probes.

    Page 6 Rev 2.2Rev 2.5

    Table Of ContentsMain Index

  • 8/12/2019 Catalog About Probe

    7/42

    Rotating Scanner Probes

    Bolt Hole Probes for Spitfire, MiniMite (4 pin Fischer), Hocking and Rohmann Scanners

    SPO-5965 expanding probes have a long wearing plastic tip and stainless steel backshell.

    Probes are fitted with a 4 pin Fischer connector. These probes are similar to SPO-5000probes but are expanded to their larger diameter. They are designed to allow the use of thesame probe when holes are reamed to a larger diameter. They are also useful to checkunusual hole sizes when a fixed size probe is unavailable.

    These probes use a reflection differential type coil operating in the 500 kHz to 3 MHzrange. This makes them suitable for aluminum structures as well as low conductivitymaterials. These probes are also available in kits.

    How to Order:

    Provide part number, description and working length

    Probe DescriptionSPO-5965 .156-.187SPO-5965 .187-.218SPO-5965 .218-.250SPO-5965 .250-.281SPO-5965 .281-.312SPO-5965 .312-.375SPO-5965 .375-.437SPO-5965 .437-.500SPO-5965 .500-.562SPO-5965 .562-.625SPO-5965 .625-.687

    SPO-5965 .687-.750SPO-5965 .750-.812

    Part Number92300619219979921998092199819219982921998392199789219984921998592301569230157

    92301589230159

    Working Length (W/L)1.751.752.002.002.002.002.002.002.002.002.00

    2.002.00

    SPO-5965

    Page 7Rev 2.2Rev 2.5

    Table Of ContentsMain Index

    W/L W/L W/L

    >.250" .100" - .249"

    Other diameters and working lengths available. Contact the Sensors department at StaveleyInstruments for more information.

  • 8/12/2019 Catalog About Probe

    8/42

    .100" - .249">.250"

    W/L W/L

    Rotating Scanner Probes

    How to Order:

    Provide part number, description and working length

    Probe DescriptionSPO-5393 5/32SPO-5393 3/16SPO-5393 7/32SPO-5393 1/4SPO-5393 9/32SPO-5393 5/16

    SPO-5393 11/32SPO-5393 3/8

    SPO-5393 13/32SPO-5393 7/16SPO-5393 1/2

    SPO-5393 9/16SPO-5393 5/8

    SPO-5393 11/16SPO-5393 3/4

    Part Number92199999220000923003592199879219988921998992199909219991921999292199939219994

    9219995921999692199979219998

    Working Length2.002.002.002.002.002.002.002.002.002.002.00

    2.002.002.002.00

    Page 8 Rev 2.2Rev 2.5

    Bolt Hole Probes for Spitfire, MiniMite (4 pin Fischer), Hocking and RohmannScanners

    SPO-5393 probes are a hybrid of the original RA probes and are fitted with a 4 pin Fischer connector.

    These probes use a reflection differential type coil operating in the 500 KHz to 3 MHz range. This

    makes them suitable for aluminum structures as well as low conductivity materials.

    The standard stock types are identified in fractions (1/2). The actual probe size isdiameter .010 (.25mm) below this size to provide clearance. Identify special orders with decimals(.505). These probes will be made to the diameter ordered without under-sizing. The working length(WL) required should also be stated. These probes are also available in kits.

    Table Of ContentsMain Index

    Other diameters and working lengths available. Contact the Sensors department at StaveleyInstruments for more information.

    SPO-5393

  • 8/12/2019 Catalog About Probe

    9/42

    How to Order:

    Provide part number, description and working length

    Rotating Scanner Probes

    Probe DescriptionRA-5/32SRA-5/16SRA-3/16RA-7/32RA-5/16RA-3/8

    RA-7/16RA-9/16RA-11/16

    Part Number921629092034869203481920348292034859203487920348892162949216295

    Working Length (W/L)0.250.301.101.101.501.501.501.501.50

    Bolt Hole Probes for RA19, RA2000 and MiniMite (4 pin Lemo) Hand Held Scanners

    RA probes are made from durable stainless steel and are non-contact probes. Probes are fitted with

    a 4 pin Lemo connector.

    These probes use a reflection differential type coil operating in the 500 KHz to 3 MHz range. Thismakes them suitable for aluminum structures as well as low conductivity materials.

    The standard stock types are identified in fractions (1/2). The actual probe size isdiameter .010 (.25mm) below this size to provide clearance. Identify special orders with decimals(.500) . These probes will be made to the diameter ordered without under-sizing. The working length(WL) required should also be stated. These probes are also available in kits.

    Probe DescriptionRA-1/4S

    RA-1/4RA-9/32RA-11/32RA-13/32

    RA-1/2RA-5/8RA-3/4

    Part Number9203484

    9203483921629192162929216293920348992034909216296

    W/L

    W/L

    Diameters

    /= .251

    .40

    Page 9Rev 2.2Rev 2.5

    Table Of ContentsMain Index

    Other diameters and working lengths available. Contact the Sensors department at StaveleyInstruments for more information.

    RA PROBES

  • 8/12/2019 Catalog About Probe

    10/42

    How to Order:

    Provide part number, description and working length

    Rotating Scanner Probes

    Probe DescriptionSPO-3564 .156-.187SPO-3564 .187-.218SPO-3564 .218-.250SPO-3564 .250-.281SPO-3564 .281-.312SPO-3564 .312-.375SPO-3564 .375-.437SPO-3564 .437-.500SPO-3564 .500-.562SPO-3564 .562-.625SPO-3564 .625-.687SPO-3564 .687-.750SPO-3564 .750-.812

    Part Number9230078921715392171549217155921715692171579217158921715992171609218785921878692187879218788

    Working Length (W/L)1.101.101.101.101.501.501.501.501.501.501.501.501.50

    Bolt Hole Probes for RA19, RA2000 and MiniMite (4 pin Lemo) Hand Held Scanners

    SPO-3564 expanding probes have a long wearing plastic tip and stainless steel backshell. Probes

    are fitted with a 4 pin Lemo connector. These are expandable to 20% above their nominal diameter.They are designed to allow the use of the same probe when holes are reamed to a larger diameter.They are also useful to check unusual hole sizes when a fixed size probe is unavailable.

    These probes use a reflection differential type coil operating in the 500 KHz to 3 MHz range. Thismakes them suitable for aluminum structures as well as low conductivity materials. These probes arealso available in kits.

    .40

    W/L

    W/L W/L

    >.251 .187-.250 .150-.186

    Page 10 Rev 2.2Rev 2.5

    Table Of ContentsMain Index

    Other diameters and working lengths available. Contact the Sensors department at StaveleyInstruments for more information.

    SPO-3564

  • 8/12/2019 Catalog About Probe

    11/42

    How to Order:

    Provide part number, description.

    1. 2. 3. 4.

    Rotating Scanner Probes

    Special Scanner Probes for RA19, RA2000, and MiniMite (4 pin Lemo) Hand HeldScanners

    These probes are fitted with a 4 pin Lemo connector and RA style coils operating in the 500 KHz to3 MHz range. This makes them suitable for first layer aluminum structures.

    1. Surface Inspection Probes (raised head fasteners)- for inspecting the immediate areasurrounding a raised head fastener.

    2. Surface Inspection Probes for use in detecting flaws emanating from under fastener heads.Inspection can be done with flush fasteners installed. Probe uses ball bearing guide for alignment.

    3. Surface Inspection Probes (non countersink)-for inspecting the immediate area outside of anon countersink hole (fastener must be removed). All probes have a pilot shaft for ease in alignment.Five sizes are available.

    4. Countersink Probes for use in detecting flaws in countersinks with the fasteners removed. All

    probes are designed for the standard 100 countersink unless otherwise specified. All probes have apilot shaft for ease in alignment. Five sizes are available.

    CountersinkSPO-4031-5/32SPO-4031-3/16SPO-4031-7/32SPO-4031-1/4SPO-4031-5/16

    Surface Inspection

    SPO-2906-(5/32 to3/16)

    SPO-4243-(3/16 to7/32)

    Part Number92165949216595921659692165979216598

    Part Number

    9216603

    9216599

    Non-CountersinkSPO-3986-5/32SPO-3986-3/16SPO-3986-7/32SPO-3986-1/4SPO-3986-5/16

    Surface Inspection(Raised fastener)

    SPO-4308-5/32

    SPO-4307-5/16

    Part Number92166049216605921660692166079216608

    Part Number

    9216602

    9216601

    Page 11Rev 2.2Rev 2.5

    Table Of ContentsMain Index

    Special Probes

  • 8/12/2019 Catalog About Probe

    12/42

    How to Order:

    Provide part number, description.

    Rotating Scanner Probes

    Special Scanner Probes for Spitfire, MiniMite (4 pin Fischer), Hocking and RohmannScanners.

    These probes are fitted with a 4 pin Fischer connector and RA style coils operating in the 500 KHz to3 MHz range. This makes them suitable for first layer aluminum structures.

    1. Surface Inspection Probes (raised head fasteners)- for inspecting the immediate areasurrounding a raised head fastener.

    2. Surface Inspection Probes for use in detecting flaws emanating from under fastener heads.Inspection can be done with flush fasteners installed. Probe uses ball bearing guide for alignment.

    3. Surface Inspection Probes (non countersink)-for inspecting the immediate area outside of anon countersink hole (fastener must be removed). All probes have a pilot shaft for ease in alignment.Five sizes are available.

    4. Countersink Probes for use in detecting flaws in countersinks with the fasteners removed. All

    probes are designed for the standard 100 countersink unless otherwise specified. All probes have apilot shaft for ease in alignment. Five sizes are available.

    CountersinkSPO-5787-5/32SPO-5787-3/16SPO-5787-7/32SPO-5787-1/4SPO-5787-5/16

    Surface Inspection

    SPO-6635-(5/32 to3/16)

    SPO-6636-(3/16 to7/32)

    Part Number92223819222382922238392223849222385

    Part Number

    9222391

    9222392

    Non-CountersinkSPO-5786-5/32SPO-5786-3/16SPO-5786-7/32SPO-5786-1/4SPO-5786-5/16

    Surface Inspection(Raised fastener)

    SPO-5784-5/32

    SPO-5785-5/16

    Part Number92223869222387922238892223899222390

    Part Number

    9222393

    9222394

    1. 2. 3. 4.

    Page 12 Rev 2.2Rev 2.5

    Table Of ContentsMain Index

    Special Probes

  • 8/12/2019 Catalog About Probe

    13/42

    How to Order:

    Provide part number, description.

    Rotating Scanner Probes

    Bolt Hole Probes for NortecPS-5 Stainless Steel and Aluminum Scanners.

    These probes are manufactured with a choice of bridge/absolute, bridge/differential or reflection/

    differential coils in a variety of frequency ranges. They have a long wearing plastic expandable tip andstainless steel backshell. These probes are expandable to 20% above their nominal diameter. They aredesigned to allow the use of the same probe when holes are reamed to a larger diameter. They are alsouseful to check unusual hole sizes when a fixed sizeprobe is unavailable.

    Standard probes are available with a 1.5 working length, other working lengths and probe diameters areavailable.

    These probes are also available in kits. The most popular kit is l isted on page 14, other kits are available.

    Page 13Rev 2.2Rev 2.5

    DescriptionPS5/100KHZ-500KHZ/A.156PS5/100KHZ-500KHZ/A.187PS5/100KHZ-500KHZ/A.218PS5/100KHZ-500KHZ/A.250PS5/100KHZ-500KHZ/A.281PS5/100KHZ-500KHZ/A.312PS5/100KHZ-500KHZ/A.343PS5/100KHZ-500KHZ/A.375PS5/100KHZ-500KHZ/A.406PS5/100KHZ-500KHZ/A.437PS5/100KHZ-500KHZ/A.468PS5/100KHZ-500KHZ/A.500PS5/100KHZ-500KHZ/A.531PS5/100KHZ-500KHZ/A.562PS5/100KHZ-500KHZ/A.593PS5/100KHZ-500KHZ/A.625PS5/100KHZ-500KHZ/A.656PS5/100KHZ-500KHZ/A.687PS5/100KHZ-500KHZ/A.718PS5/100KHZ-500KHZ/A.750

    Part Number92176289217629921763092176319217632921763392176349217635921763692176379217638921763992176409217641921764292176439217644921764592176469217647

    DescriptionPS5/500KHZ-2MHZ/D.156PS5/500KHZ-2MHZ/D.187PS5/500KHZ-2MHZ/D.218PS5/500KHZ-2MHZ/D.250PS5/500KHZ-2MHZ/D.281PS5/500KHZ-2MHZ/D.312PS5/500KHZ-2MHZ/D.343PS5/500KHZ-2MHZ/D.375PS5/500KHZ-2MHZ/D.406PS5/500KHZ-2MHZ/D.437PS5/500KHZ-2MHZ/D.468PS5/500KHZ-2MHZ/D.500PS5/500KHZ-2MHZ/D.531PS5/500KHZ-2MHZ/D.562PS5/500KHZ-2MHZ/D.593PS5/500KHZ-2MHZ/D.625PS5/500KHZ-2MHZ/D.656PS5/500KHZ-2MHZ/D.687PS5/500KHZ-2MHZ/D.718PS5/500KHZ-2MHZ/D.750

    Part Number92176489217520921764992175219217650921752292176519217523921765292175249217653921752592176549217526921765592175279217656921765792176589217528

    DescriptionPS5/200KHZ-1MHZ/RD.156PS5/200KHZ-1MHZ/RD.187PS5/200KHZ-1MHZ/RD.218PS5/200KHZ-1MHZ/RD.250PS5/200KHZ-1MHZ/RD.281PS5/200KHZ-1MHZ/RD.312PS5/200KHZ-1MHZ/RD.343PS5/200KHZ-1MHZ/RD.375PS5/200KHZ-1MHZ/RD.406PS5/200KHZ-1MHZ/RD.437PS5/200KHZ-1MHZ/RD.468PS5/200KHZ-1MHZ/RD.500PS5/200KHZ-1MHZ/RD.531PS5/200KHZ-1MHZ/RD.562PS5/200KHZ-1MHZ/RD.593PS5/200KHZ-1MHZ/RD.625PS5/200KHZ-1MHZ/RD.656PS5/200KHZ-1MHZ/RD.687PS5/200KHZ-1MHZ/RD.718PS5/200KHZ-1MHZ/RD.750

    Part Number92175699217570921757192175729217573921757492175759217576921757792175789217579921758092175819217582921758392175849217585921758692175879217588

    Table Of ContentsMain Index

    2.46

    2.46

    PS-5 Scanner Probes

  • 8/12/2019 Catalog About Probe

    14/42

    Rotating Scanner Probes

    Bolt Hole Probe Kits for NortecPS-5 Stainless Steel and Aluminum Scanners.

    How to Order:Provide part number, description.

    PS5/200KHZ-1MHZ/RD.156

    PS5/200KHZ-1MHZ/RD.187PS5/200KHZ-1MHZ/RD.218PS5/200KHZ-1MHZ/RD.250PS5/200KHZ-1MHZ/RD.281PS5/200KHZ-1MHZ/RD.312PS5/200KHZ-1MHZ/RD.343PS5/200KHZ-1MHZ/RD.375PS5/200KHZ-1MHZ/RD.406PS5/200KHZ-1MHZ/RD.437PS5/200KHZ-1MHZ/RD.468PS5/200KHZ-1MHZ/RD.500PS5/200KHZ-1MHZ/RD.531PS5/200KHZ-1MHZ/RD.562PS5/200KHZ-1MHZ/RD.593PS5/200KHZ-1MHZ/RD.625PS5/200KHZ-1MHZ/RD.656PS5/200KHZ-1MHZ/RD.687PS5/200KHZ-1MHZ/RD.718PS5/200KHZ-1MHZ/RD.750

    Probe Kit, PS5 AFPart Number 9217666NSN 6635-01-415-9099

    PS5/100KHZ-500KHZ/A.156

    PS5/100KHZ-500KHZ/A.187PS5/100KHZ-500KHZ/A.218PS5/100KHZ-500KHZ/A.250PS5/100KHZ-500KHZ/A.281PS5/100KHZ-500KHZ/A.312PS5/100KHZ-500KHZ/A.343PS5/100KHZ-500KHZ/A.375PS5/100KHZ-500KHZ/A.406PS5/100KHZ-500KHZ/A.437PS5/100KHZ-500KHZ/A.468PS5/100KHZ-500KHZ/A.500PS5/100KHZ-500KHZ/A.531PS5/100KHZ-500KHZ/A.562PS5/100KHZ-500KHZ/A.593PS5/100KHZ-500KHZ/A.625PS5/100KHZ-500KHZ/A.656PS5/100KHZ-500KHZ/A.687PS5/100KHZ-500KHZ/A.718PS5/100KHZ-500KHZ/A.750

    Probe Kit, PS5 AbsolutePart Number 9230230

    PS5/500KHZ-2MHZ/D.156

    PS5/500KHZ-2MHZ/D.187PS5/500KHZ-2MHZ/D.218PS5/500KHZ-2MHZ/D.250PS5/500KHZ-2MHZ/D.281PS5/500KHZ-2MHZ/D.312PS5/500KHZ-2MHZ/D.343PS5/500KHZ-2MHZ/D.375PS5/500KHZ-2MHZ/D.406PS5/500KHZ-2MHZ/D.437PS5/500KHZ-2MHZ/D.468PS5/500KHZ-2MHZ/D.500PS5/500KHZ-2MHZ/D.531PS5/500KHZ-2MHZ/D.562PS5/500KHZ-2MHZ/D.593PS5/500KHZ-2MHZ/D.625PS5/500KHZ-2MHZ/D.656PS5/500KHZ-2MHZ/D.687PS5/500KHZ-2MHZ/D.718PS5/500KHZ-2MHZ/D.750

    Probe Kit, PS5 DifferentialPart Number 9230231

    PS-5 PROBE KITDIFFERENTIAL

    P/N 9230231

    PS-5 PROBE KIT AFP/N 9217666

    NSN: 6635-01-415-9099

    PS-5 PROBE KITABSOLUTEP/N 9230230

    Page 14 Rev 2.2Rev 2.5

    PS-5 Scanner Probes

    Table Of ContentsMain Index

  • 8/12/2019 Catalog About Probe

    15/42

    Rotating Scanner Probes

    Bolt Hole Probes for PS-2 and PS-3 Scanners.

    The SA and SD scanner bolt hole probes are fitted with 4 pin Switchcraft connectors and available with

    absolute or differential coils in bridge configuration.

    The SA type absolute probe has a shielded 100 kHz coil for aluminum structures. SD type differentialprobes have 500 kHz shielded coils for aluminum and/or low conductivity materials, and provideincreased sensitivity to small defects. Other frequencies are available. Probe body material is of BlackDelrin unless otherwise specified.

    How to Order standard probes:

    Provide part number, description.Example:

    How to Order non-standard probes:Example:

    Special order probes should be identified with size in decimals (.505) Working length (WL) required should be stated if different from the standard3.0. If coil is recessed add R

    Notes: Probes below .160 are unshielded and have no expansion slot or cheeks. Probes below .220 have no ball end.

    SA and SD Scanner Probes

    9216318Part Number

    SDAbsolute (SA) or Differential (SD)

    16Probe Size in X/64

    RAdd R if coil is recessed

    SDAbsolute (SA) or Differential (SD)

    .325Probe diameter

    500 kHzFrequency

    2 W/LWorking Length

    Diameter of probeor Hole

    SA AbsoluteShielded

    PartNumber

    SD DifferentialShielded

    PartNumber

    Working Length(WL)

    .156

    .187

    .218

    .250

    .281

    .312

    .343

    .375

    .406

    .437

    .500

    .562

    .625

    .687

    .750

    4.0mm4.7mm5.5mm6.3mm7.1mm7.9mm

    8.7mm9.5mm10.3mm11.1mm12.7mm14.3mm15.9mm17.5mm19.0mm

    5/323/167/321/49/325/16

    11/323/8

    13/327/161/29/165/8

    11/163/4

    SA-10SA-12SA-14SA-16SA-18SA-20

    SA-22SA-24SA-26SA-28SA-32SA-36SA-40SA-44SA-48

    921629992163019216302921630392163049216305921630692163079216308921630992163109216311921631292163139216314

    SD-10SD-12SD-14SD-16SD-18SD-20SD-22SD-24SD-26SD-28SD-32SD-36SD-40SD-44SD-48

    921631592163169216317921631892163199216320921632192163229216323921632492163259216326921632792163289216329

    1.41.41.41.41.43.03.03.03.03.03.03.03.03.03.0

    Page 15Rev 2.2Rev 2.5

    Table Of ContentsMain Index

    *Other diameters and working lengths can be made to special order. Standard frequency range for SA absolute probes is 100 KHzto 500KHz. Standard frequency range for SD differential probes is 500KHz to 2MHz.

  • 8/12/2019 Catalog About Probe

    16/42

    Rotating Scanner Probes

    Non-Contact Bolt Hole Probes for RC RECHII Scanners

    The RC Scanner Bolt hole probes are fitted with a 4 pin Switchcraft connector. RC probes are made of

    stainless steel.

    The standard coils used are reflection differential. They offer a wide frequency range (typically 500 KHzto 2 MHz) with good signal-to-noise ratio.

    RC probes are manufactured for the RECHII High Speed (1500 rpm) Scanner. These probes are notinterchangeable with the PS-2 or PS-3 scanners.

    Non-Contact RC style probes are normally ordered .010 (.25mm) less than the hole diameter forclearance. They will operate with more clearance (depending on defect size) with reduced sensitivity.

    All RECHII probes are custom made to customer specifications.

    How to Order:

    Provide Probe Type, Probe diameter and Working length.

    Example:

    When ordering

    All RC probe sizes should be identified using decimals (.___). The probe will be made to the diameter ordered withoutunder sizing. Working lengths should be requested when placing an order.

    RC Scanner Probes are available from .050 to 1.500 in diameter. They are designed to be used with the RECHII IIscanner and NDT-25L with RECHII option instruments. They are used to detect minute cracks and defects in titanium,inconel and other low conductivity alloys.

    RC Scanner Probes

    RCBProbe Type

    .240Probe Diameter

    WL.800Working Length

    RCSAvailable Diameters

    .050 to .129

    RCAAvailable Diameters

    .130 to .169

    RCBAvailable Diameters

    .170 to .624

    RCCAvailable Diameters

    .625 to 1.500

    Page 16 Rev 2.2Rev 2.5

    Table Of ContentsMain Index

  • 8/12/2019 Catalog About Probe

    17/42

    Rotating Scanner Probes

    Bolt Hole Probes for PS-4 Scanner.(Contact and Non-Contact)

    The standard PS-4 probes are fitted with a 6 pin Lemo connector. These probes are made with analuminum backshell and a high quality plastic tip.

    The standard coils used are reflection differential, double-ended, shielded. They offer a wide frequencyrange (typically 500 Khz-4 Mhz) with optimum signal to noise ratio. They are used for detecting minutecracks and defects in titanium, inconel and other low conductivity alloys. These probes are offered inthree different styles:

    1. SNC (Staveley Non-Contact) are normally ordered .010 (.25mm) less than the hole diameter forclearance. The will operate with more clearance (depending on the defect size) with reducedsensitivity.

    2. SCR (Staveley Contact Recessed) are expandable to maintain surface contact. They can beexpanded up to 10% of their nominal size. SCR coils are recessed slightly below the contact surface

    which reduces scanning noise and does not require protective tape.

    3. SC (Staveley Contact)are the same as SCR probes except the coil is not recessed. They provide thebest sensitivity but require protective tape.

    All PS-4 probes are custom made to customer specifications.

    How to Order:

    Provide Probe Type, Probe diameter and Frequency.Example:

    (SCR Staveley Contact Recessed)(SC Staveley Contact)

    (SNC- Staveley Non-Contact)

    SCR, SNC and SC Scanner Probes

    SCRProbe Type

    .239Probe Diameter

    -S/2Frequency in MHz

    -S/2 = 2Mhz-S/6 = 6Mhz

    Page 17Rev 2.2Rev 2.5

    Table Of ContentsMain Index

  • 8/12/2019 Catalog About Probe

    18/42

    Scanner Probe Kits

    RA19, RA2000 and MiniMite (4 pin Lemo) Bolt Hole Probe Kits

    Stainless Steel, Non Contact

    Two Probe Kits are available:

    The Standard Kit brings together eight of our most popular sizes in a convenientcarrying case.

    The Deluxe Kit is made of 15 sizes ranging from 5/32 to 3/4 in a convenientcarrying case.

    Both kits are comprised of our stock, high quality, stainless steel probes. All aremanufactured .010 (.25mm) less than the fractional sizes shown. Standard workinglengths are supplied.

    Expanding probes, Contact

    Expandable Kit contains eight SPO-3564 probes to cover hole sizes from .187 toover .500. These probes have an expansion range of about 20%.

    RA19, 2000 and MiniMite 4 pin Lemo Scanner Kits

    How to Order

    Provide stock part number and description.

    Example: 9216656 Standard RA Kit

    Standard RA KitPart Number 9216656

    Includes:

    92034819203482920348392134859203487920348892034899203490Carrying Case

    RA-3/16RA-7/32RA-1/4RA-5/16RA-3/8RA-7/16RA-1/2RA-5/8

    Deluxe RA KitPart Number 9216657

    Includes:

    921629092162939203481920348892034829203489920348392162949216291

    920349092034859216295921629292162969203487Carrying Case

    RA-5/32RA-13/32RA-3/16RA-7/16RA-7/32RA-1/2RA-1/4RA-9/16RA-9/32

    RA-5/8RA-5/16RA-11/16RA-11/32RA-3/4RA-3/8

    Expandable Kit (SPO-3564)Part Number 9216658

    Includes:

    92171539217154921715592171569217157921715892171599217160Carrying Case

    SPO-3564 .187-.218SPO-3564 .218-.250SPO-3564 .250-.281SPO-3564 .281-.312SPO-3564 .312-.375SPO-3564 .375-.437SPO-3564 .437-.500SPO-3564 .500-.562

    Deluxe RA Probe Kit

    Expandable(SPO-3564)

    Kit

    Page 18 Rev 2.2Rev 2.5

    Table Of ContentsMain Index

  • 8/12/2019 Catalog About Probe

    19/42

  • 8/12/2019 Catalog About Probe

    20/42

    Detachable Bolt Hole Probes

    How to Order:

    Provide part number, description.

    Example:

    Probe Diameter.156.187.218.250.281.312.343.375.406

    .437.500

    .562

    .625

    .687

    .750

    Part Number922243392222179222434922221892224359222219922243692222209222437

    922222192224389222439922222392224409222224

    Absolute ShieldedBL/100KHZ-500KHZ/A.156BL/100KHZ-500KHZ/A.187BL/100KHZ-500KHZ/A.218BL/100KHZ-500KHZ/A.250BL/100KHZ-500KHZ/A.281BL/100KHZ-500KHZ/A.312BL/100KHZ-500KHZ/A.343BL/100KHZ-500KHZ/A.375BL/100KHZ-500KHZ/A.406

    BL/100KHZ-500KHZ/A.437BL/100KHZ-500KHZ/A.500BL/100KHZ-500KHZ/A.562BL/100KHZ-500KHZ/A.625BL/100KHZ-500KHZ/A.687BL/100KHZ-500KHZ/A.750

    BL/Bolt Hole

    *BRL if reflection coil

    9222218Part Number

    100KHZ-500KHZFrequency Range

    /AAbsolute

    (D if Differentialcoil

    .250Probe/ Hole diameter

    Note: Probes .156 and below are unshielded and have no expansion slot. Probes below .236 have no ball end. Collaris non-removable in probes .250 to .531 in diameter.

    Part Number922244192224429222443922244492224459222446922244792224489222449

    922245092224519222452922245392224549222455

    Differential ShieldedBL/500KHZ-2MHZ/D.156BL/500KHZ-2MHZ/D.187BL/500KHZ-2MHZ/D.218BL/500KHZ-2MHZ/D.250BL/500KHZ-2MHZ/D.281BL/500KHZ-2MHZ/D.312BL/500KHZ-2MHZ/D.343BL/500KHZ-2MHZ/D.375BL/500KHZ-2MHZ/D.406

    BL/500KHZ-2MHZ/D.437BL/500KHZ-2MHZ/D.500BL/500KHZ-2MHZ/D.562BL/500KHZ-2MHZ/D.625BL/500KHZ-2MHZ/D.687BL/500KHZ-2MHZ/D.750

    Working length (WL)1.01.01.02.02.02.02.02.02.0

    2.02.03.23.23.23.2

    *When ordering reflection coils (special order) omit part number and order by description. Lengths shown are approximate.

    PowerLink Manual Bolt Hole Probes, Absolute and Differential

    The PowerLink detachable bolt hole probes are manual probes available with absolute or differential

    coils in bridge or reflection configurations. Internal reference coils ensure accurate balance withoutexternal adaptors. All probes are supplied with an adjustable collar. Common cable compatibility amongmost PowerLink eddy current probes allows one cable to operate probes in either bridge or reflectionconfiguration. All Nortec PowerLink eddy current probesare backward compatible to Nortec NDT-19 and NDT-24instruments. Cables CL/SC/6 for Nortec 2000 series andC/SC/6 7P for NDT-19 and NDT-24 instruments, are soldseperately.

    PowerLink technology offers unmatched performancewhen used with Staveleys new eddy currentinstrumentation. PowerLink features automatic proberecognition and documentation, as well as providing theoptimum integration between instrument and sensor.

    WL

    WL

    Page 20 Rev 2.2Rev 2.5

    Table Of ContentsMain Index

    PowerLink Manual Bolt Hole Probes

  • 8/12/2019 Catalog About Probe

    21/42

    Standard Absolute (Bridge type non-PowerLink)

    Part Number92133999213400

    Differential Shielded3551 RDF 500Khz3551 RDF 3Mhz

    Part Number92133979213398

    Differential Unshielded3551 RD 500Khz3551 RD 3Mhz

    Frequency Range500Khz-3Mhz3Mhz-6Mhz

    Nortec3551 Pencil Probes

    The 3551 type pencil probes are supplied with a built-in small diameter, low noise cable and an

    adjustable collar. They are available with absolute or differential coils in both bridge and reflectionconfigurations (shielded and unshielded). Shielded coils have an effective sensitive areaapproximately .08 (2mm) diameter. Probes will be supplied with Nortec 8 pin Burndy connectorunless otherwise specified.

    How to Order:

    Provide part number, description.

    Example:

    Nortec3551 Pencil Probes

    3551 Pencil Probes

    3551FType

    9204914Part Number

    100KHZFrequency

    Frequency Range50Khz-100Khz100Khz-500Khz500Khz-1Mhz1Mhz-2Mhz2Mhz-4Mhz4Mhz-6Mhz

    Part Number921338292049109204911920491292049139213383

    Absolute Unshielded3551 50Khz3551 100Khz3551 500Khz3551 1Mhz3551 2Mhz3551 4Mhz

    Absolute Shielded3551 F 50Khz3551 F 100Khz3551 F 500Khz3551 F 1Mhz3551 F 2Mhz3551 F 4Mhz

    Part Number921338492049149204915920491692049179213385

    Frequency Range100Khz-500Khz500Khz-2Mhz2Mhz-4Mhz4Mhz-6Mhz

    Part Number9216590921338692133879213388

    Differential Unshielded3551 D 100Khz3551 D 500Khz3551 D 2Mhz3551 D 4Mhz

    Standard Differential (Bridge type non-PowerLink)

    Differential Shielded3551 DF 100Khz3551 DF 500Khz3551 DF 2Mhz3551 DF 4Mhz

    Part Number9216591921338992134289213390

    Frequency Range1Khz-100Khz100Khz-1Mhz1Mhz-3Mhz3Mhz-6Mhz

    Part Number9216592*921339192133929213393

    Absolute Unshielded3551 R 1Khz

    3551 R 100Khz3551 R 1Mhz3551 R 3Mhz

    Reflection Absolute (non-PowerLink)

    Absolute Shielded3551 RF 1Khz

    3551 RF 100Khz3551 RF 1Mhz3551 RF 3Mhz

    Part Number9216593*921339492133959213396

    Reflection Differential (non-PowerLink)

    Page 21Rev 2.5

    Table Of ContentsMain Index

    The 3551 probe has a standard O.D. = .18* Probe diameter =.25

  • 8/12/2019 Catalog About Probe

    22/42

    Nortec3551L PowerLink Pencil Probes

    The 3551L type pencil probes are supplied with a built-in small diameter, low noise cable and an

    adjustable collar. They are available with absolute or differential coils in both bridge and reflectionconfigurations (shielded and unshielded). Shielded coils have an effective sensitive areaapproximately .08 (2mm) diameter. Probes will be supplied with a Lemo 16 pin connector.

    How to Order:

    Provide part number, description.

    Example:

    NortecPowerLink 3551L Pencil Probes

    3551 Pencil Probes

    3551FLType

    9230122Part Number

    100KHZFrequency

    Frequency Range50Khz-100Khz100Khz-500Khz500Khz-1Mhz1Mhz-2Mhz2Mhz-4Mhz4Mhz-6Mhz

    Part Number923011592301169230117923011892301199230120

    Absolute Unshielded3551L 50Khz3551 L 100Khz3551 L 500Khz3551 L 1Mhz3551 L 2Mhz3551 L 4Mhz

    Standard Absolute (Bridge type)

    Absolute Shielded3551 FL 50Khz3551 FL 100Khz3551 FL 500Khz3551 FL 1Mhz3551 FL 2Mhz3551 FL 4Mhz

    Part Number923012192301229230123923012492301259230126

    Frequency Range100Khz-500Khz500Khz-2Mhz2Mhz-4Mhz4Mhz-6Mhz

    Part Number9230127923012892301299230130

    Differential Unshielded3551 DL 100Khz3551 DL 500Khz3551 DL 2Mhz3551 DL 4Mhz

    Standard Differential (Bridge type)

    Differential Shielded3551 DFL 100Khz3551 DFL 500Khz3551 DFL 2Mhz3551 DFL 4Mhz

    Part Number9230131923013292301339230134

    Frequency Range1Khz-100Khz100Khz-1Mhz1Mhz-3Mhz

    Part Number9230103*92301049230105

    Absolute Unshielded3551 RL 1Khz

    3551 RL 100Khz3551 RL 1Mhz

    Reflection Absolute

    Absolute Shielded3551 RFL 1Khz

    3551 RFL 100Khz3551 RFL 1Mhz

    Part Number9230107*92301089230109

    Frequency Range500Khz-3Mhz3Mhz-6Mhz

    Part Number92301119230112

    Differential Unshielded3551 RDL 500Khz3551 RDL 3Mhz

    Reflection Differential

    Differential Shielded3551 RDFL 500Khz3551 RDFL 3Mhz

    Part Number92301139230114

    Page 22 Rev 2.2Rev 2.5

    Table Of ContentsMain Index

    The 3551 probe has a standard O.D. = .18* Probe diameter =.25

  • 8/12/2019 Catalog About Probe

    23/42

    .43

    NortecStandard Detachable Pencil Probes

    The Nortec standard detachable pencil probes are supplied with an adjustable collar and a high quality

    quick release connector.

    They are available with absolute or differential coils in both bridge and reflection configurations (shieldedand unshielded). Shielded coils have an effective sensitive area approximately .08 (2mm) diameter.

    Cables sold separately.

    How to Order:

    Provide part number, description.

    Example:

    NortecStandard Detachable Pencil Probes

    Detachable Pencil Probes

    PPencil, (PR if reflection)

    9213408Part Number

    /100KHZ-500KHZ/Frequency range

    Frequency Range50Khz-100Khz100Khz-500Khz500Khz-1Mhz1Mhz-2Mhz2Mhz-4Mhz4Mhz-6Mhz

    Part Number921340192134029213403921340492134059213406

    Absolute UnshieldedP/50Khz-100Khz/AUP/100Khz-500Khz/AUP/500Khz-1Mhz/AUP/1Mhz-2Mhz/AUP/2Mhz-4Mhz/AUP/4Mhz-6Mhz/AU

    Detachable Absolute (Bridge type)

    Absolute ShieldedP/50Khz-100Khz/AP/100Khz-500Khz/AP/500Khz-1Mhz/AP/1Mhz-2Mhz/AP/2Mhz-4Mhz/AP/4Mhz-6Mhz/A

    Part Number921340792134089213014921340992134109213411

    Frequency Range500Khz-2Mhz2Mhz-4Mhz4Mhz-6Mhz

    Part Number921341292134139213414

    Differential UnshieldedP/500Khz-2Mhz/DUP/2Mhz-4Mhz/DUP/4Mhz-6Mhz/DU

    Detachable Differential (Bridge type)

    Differential ShieldedP/500Khz-2Mhz/DP/2Mhz-4Mhz/DP/4Mhz-6Mhz/D

    Part Number921301592134159213416

    Frequency Range1Khz-100Khz100Khz-1Mhz1Mhz-3Mhz

    Part Number9216538*92134179213418

    Absolute UnshieldedPR/1Khz-100Khz/AUPR/100Khz-1Mhz/AUPR/1Mhz-3Mhz/AU

    Detachable Reflection Absolute

    Absolute ShieldedPR/1Khz-100Khz/APR/100Khz-1Mhz/APR/1Mhz-3Mhz/A

    Part Number9216539*92134209213421

    Frequency Range500Khz-3Mhz3Mhz-6Mhz

    Part Number92134239213424

    Differential UnshieldedPR/500Khz-3Mhz/DUPR/3Mhz-6Mhz/DU

    Detachable Reflection Differential

    Differential ShieldedPR/500Khz-3Mhz/DPR/3Mhz-6Mhz/D

    Part Number92134259213426

    AAbsolute (D if differential)

    Page 23Rev 2.2Rev 2.5

    Table Of ContentsMain Index

    For bridge probes use cables C/SC/6 (P/N 9113016) or C/RA/6 (P/N 9113017). For reflection probes use cables CR/SC/6 (P/N 9113429)or CR/RA/6 (P/N 9113430). The above probes have a standard O.D. = .18, * Probe diameter =.25

  • 8/12/2019 Catalog About Probe

    24/42

    .43

    NortecPowerLink Detachable Pencil Probes

    The Nortec PowerLinkdetachable pencil probes are supplied with an adjustable collar and a high

    quality quick release connector.

    They are available with absolute or differential coils in both bridge and reflection configurations (shieldedand unshielded). Shielded coils have an effective sensitive area approximately .08 (2mm) diameter.

    Cables sold separately.

    How to Order:

    Provide part number, description.

    Example:

    NortecPowerLink Detachable Pencil Probes

    Detachable Pencil Probes

    PLPencil, (PRL if reflection)

    9222180Part Number

    /100KHZ-500KHZ/Frequency range

    Frequency Range50Khz-100Khz100Khz-500Khz500Khz-1Mhz1Mhz-2Mhz2Mhz-4Mhz4Mhz-6Mhz

    Part Number922241192224129222413922241492224159222417

    Absolute UnshieldedPL/50Khz-100Khz/AUPL/100Khz-500Khz/AUPL/500Khz-1Mhz/AUPL/1Mhz-2Mhz/AUPL/2Mhz-4Mhz/AUPL/4Mhz-6Mhz/AU

    Detachable Absolute (Bridge type)

    Absolute ShieldedPL/50Khz-100Khz/APL/100Khz-500Khz/APL/500Khz-1Mhz/APL/1Mhz-2Mhz/APL/2Mhz-4Mhz/APL4Mhz-6Mhz/A

    Part Number922217992221809222162922218192224169222418

    Frequency Range500Khz-2Mhz2Mhz-4Mhz4Mhz-6Mhz

    Part Number922242692224279222428

    Differential UnshieldedPL/500Khz-2Mhz/DUPL/2Mhz-4Mhz/DUPL/4Mhz-6Mhz/DU

    Detachable Differential (Bridge type)

    Differential ShieldedPL/500Khz-2Mhz/DPL/2Mhz-4Mhz/DPL/4Mhz-6Mhz/D

    Part Number922218492221859222186

    Frequency Range1Khz-100Khz100Khz-1Mhz1Mhz-3Mhz

    Part Number9222419*92224219222422

    Absolute UnshieldedPRL/1Khz-100Khz/AUPRL/100Khz-1Mhz/AUPRL/1Mhz-3Mhz/AU

    Detachable Reflection Absolute

    Absolute ShieldedPRL/1Khz-100Khz/APRL/100Khz-1Mhz/APRL/1Mhz-3Mhz/A

    Part Number9222420*92221889222423

    Frequency Range500Khz-3Mhz3Mhz-6Mhz

    Part Number92224309222431

    Differential UnshieldedPRL/500Khz-3Mhz/DUPRL/3Mhz-6Mhz/DU

    Detachable Reflection Differential

    Differential ShieldedPRL/500Khz-3Mhz/DPRL/3Mhz-6Mhz/D

    Part Number92221639222432

    AAbsolute (D if differential)

    Page 24 Rev 2.2Rev 2.5

    Table Of ContentsMain Index

    The above probes have a standard O.D. = .18, * Probe diameter =.25Probes use CL/SC/6 cable (P/N 9122083).

  • 8/12/2019 Catalog About Probe

    25/42

    Total Length

    Drop

    NortecStandard Detachable Metal Shaft Pencil Probes

    These general purpose probes are used for surface or near surface crack detection. They are also used

    for conductivity and coating thickness measurements. They are available with absolute coils in the bridgeconfiguration (shielded, unshielded and reflection shielded). Reference coils are internal, insuring thebest match to the test coil without an external adapter. These probes include a high quality quick releaseconnector. Cables sold separately.

    How to Order:

    Provide part number, description.

    Example:

    NortecStandard Detachable Metal Shaft Probes

    Detachable Pencil Probes

    PPencil, (PR if reflection)

    9213408Part Number

    /100KHZ-500KHZ/Frequency range

    Frequency Range50Khz-100Khz100Khz-500Khz500Khz-1Mhz1Mhz-2Mhz

    Part Number9216190921619192161929216193

    Absolute ShieldedP/50Khz-100Khz/A/0.0/4P/100Khz-500Khz/A/0.0/4P/500Khz-1Mhz/A/0.0/4P/1Mhz-2Mhz/A/0.0/4

    Straight Shaft

    Reflection Absolute ShieldedPR/50Khz-500Khz/A/0.0/4

    PR/500Khz-2Mhz/A/0.0/4

    Part Number9216194

    9216195

    Right Angle Shaft .03 Drop

    Right Angle Shaft .25 Drop

    Right Angle Shaft .50 Drop

    AAbsolute Coil

    /90Angle at tip

    .5Drop at tip

    /6Total Length

    Frequency Range50Khz-100Khz

    100Khz-500Khz500Khz-1Mhz1Mhz-2Mhz

    Part Number9216200921620192162029216203

    Absolute ShieldedP/50Khz-100Khz/A/90.03/6P/100Khz-500Khz/90.03/6P/500Khz-1Mhz/A/90.03/6P/1Mhz-2Mhz/A/90.03/6

    Reflection Absolute ShieldedPR/50Khz-500Khz/A/90.03/6

    PR/500Khz-2Mhz/A/90.03/6

    Part Number9216204

    9216205

    Frequency Range50Khz-100Khz

    100Khz-500Khz500Khz-1Mhz1Mhz-2Mhz

    Part Number9216210921621192162129216213

    Absolute ShieldedP/50Khz-100Khz/A/90.25/6P/100Khz-500Khz/90.25/6P/500Khz-1Mhz/A/90.25/6P/1Mhz-2Mhz/A/90.25/6

    Reflection Absolute ShieldedPR/50Khz-500Khz/A/90.25/6

    PR/500Khz-2Mhz/A/90.25/6

    Part Number9216214

    9216215

    Frequency Range50Khz-100Khz

    100Khz-500Khz500Khz-1Mhz1Mhz-2Mhz

    Part Number9216220921301392162219216222

    Absolute ShieldedP/50Khz-100Khz/A/90.5/6P/100Khz-500Khz/90.5/6P/500Khz-1Mhz/A/90.5/6P/1Mhz-2Mhz/A/90.5/6

    Reflection Absolute ShieldedPR/50Khz-500Khz/A/90.5/6

    PR/500Khz-2Mhz/A/90.5/6

    Part Number9216223

    9216224

    Page 25Rev 2.2Rev 2.5

    Table Of ContentsMain Index

    For bridge probes use cables C/SC/6 (P/N 9113016) or C/RA/6 (P/N 9113017). For reflection probes use cables CR/SC/6 (P/N 9113429)or CR/RA/6 (P/N 9113430). Other angles, drops and lengths available.

  • 8/12/2019 Catalog About Probe

    26/42

    Total Length

    Drop

    NortecPowerLink Detachable Metal Shaft Pencil Probes

    These PowerLink Metal Shaft probes are used for surface or near surface crack detection. They are

    also used for conductivity and coating thickness measurements. They are available with absolute coils inthe bridge configuration (shielded, unshielded and reflection shielded). Reference coils are internal,insuring the best match to the test coil without an external adapter. Common cable compatibility amongmost PowerLink eddy current probes allows one cable to operate probes in either bridge or reflectionconfiguration. All Nortec PowerLink eddy current probes are backward compatible to NortecNDT-19 and NDT-24 instruments. Cables CL/SC/6 for Nortec 2000 series and C/SC/6 7P for NDT-19and NDT-24 instruments, are sold seperately.

    How to Order:

    Provide part number, description.

    Example:

    NortecStandard Detachable Metal Shaft Probes

    Detachable Pencil Probes

    MLML= Bridge

    MRL= Reflection

    9222164Part Number

    /100KHZ-500KHZ/Frequency range

    Frequency Range50Khz-100Khz100Khz-500Khz500Khz-1Mhz1Mhz-2Mhz

    Part Number9222165922220292222039222472

    Absolute ShieldedML/50Khz-100Khz/A/0.0/4ML/100Khz-500Khz/A/0.0/4ML/500Khz-1Mhz/A/0.0/4ML/1Mhz-2Mhz/A/0.0/4

    Straight Shaft

    Reflection Absolute ShieldedMRL/50Khz-500Khz/A/0.0/4

    MRL/500Khz-2Mhz/A/0.0/4

    Part Number9222209

    9222210

    Right Angle Shaft .03 Drop

    Right Angle Shaft .25 Drop

    Right Angle Shaft .50 Drop

    AAbsolute Coil

    /90Angle at tip

    .5Drop at tip

    /6Total Length

    Frequency Range50Khz-100Khz

    100Khz-500Khz500Khz-1Mhz1Mhz-2Mhz

    Part Number9222473922220492222059230022

    Absolute ShieldedML/50Khz-100Khz/A/90.03/6ML/100Khz-500Khz/90.03/6ML/500Khz-1Mhz/A/90.03/6ML/1Mhz-2Mhz/A/90.03/6

    Reflection Absolute ShieldedMRL/50Khz-500Khz/A/90.03/6

    MRL/500Khz-2Mhz/A/90.03/6

    Part Number9222477

    9222478

    Frequency Range50Khz-100Khz

    100Khz-500Khz500Khz-1Mhz1Mhz-2Mhz

    Part Number9222474922220692222079230004

    Absolute ShieldedML/50Khz-100Khz/A/90.25/6ML/100Khz-500Khz/90.25/6ML/500Khz-1Mhz/A/90.25/6ML/1Mhz-2Mhz/A/90.25/6

    Reflection Absolute ShieldedMRL/50Khz-500Khz/A/90.25/6

    MRL/500Khz-2Mhz/A/90.25/6

    Part Number9222213

    9222214

    Frequency Range50Khz-100Khz

    100Khz-500Khz500Khz-1Mhz1Mhz-2Mhz

    Part Number9222476922216492222089230071

    Absolute ShieldedML/50Khz-100Khz/A/90.5/6ML/100Khz-500Khz/90.5/6ML/500Khz-1Mhz/A/90.5/6ML/1Mhz-2Mhz/A/90.5/6

    Reflection Absolute ShieldedMRL/50Khz-500Khz/A/90.5/6

    MRL/500Khz-2Mhz/A/90.5/6

    Part Number9222215

    9222216

    Page 26 Rev 2.2Rev 2.5

    Table Of ContentsMain Index

    Probes use CL/SC/6 cable (P/N 9122083). Other angles, drops and lengths available.

  • 8/12/2019 Catalog About Probe

    27/42

    NortecStandard Detachable Surface Probes

    Detachable surface probes are available in a variety of diameters and frequency ranges. They are

    shielded to provide maximum sensitivity and are used for crack detection as well as thicknessmeasurement. Other applications include conductivity and coating thickness measurements. Theseprobes include a high quality quick release connector. Cables sold separately.

    How to Order:

    Provide part number, description.

    Example:

    NortecStandard Detachable Surface Probes

    Detachable Surface Probes

    SSurface, (SR if reflection)

    9213012Part Number

    /1KHZ-50KHZFrequency range

    Frequency Range100Hz-2Khz300Hz-10Khz400Hz-30Khz500Hz-40Khz1Khz-50Khz

    5Khz-100Khz100Khz-500Khz

    DescriptionS/100Hz-2Khz/.75S/300Hz-10Khz/.62S/400Hz-30Khz/.50S/500Hz-40Khz/.44S/1Khz-50Khz/.31S/5Khz-100Khz/.25

    S/100Khz-500Khz/.25

    Standard Bridge

    Equivalent to Non Detachable SPO Probe

    SPO-565, SPO-1125SPO-565A

    SPO-1402, SPO-1391SPO-1284, SPO-1598

    SPO-2132

    Part Number9213549921301192135489213547921301292135469216541

    Standard Reflection

    /.31Diameter

    Diameter.75.62.50.44.31.25.25

    Frequency Range

    100Hz-5Khz100Hz-20Khz300Hz-40Khz

    400Hz-60Khz700Hz-80Khz2Khz-200Khz

    Description

    SR/100Hz-5Khz/.75SR/100Hz-20Khz/.62SR/300Hz-40Khz/.50

    SR/400Hz-60Khz/.44SR/700Hz-80Khz/.31SR/2Khz-200Khz/.25

    Equivalent to Non Detachable Alcoprobe andSPO ProbesAPS/20/S

    APG/16/S, SPO-2134APB/12.5/S, SPO-2136

    APBK/10.5/S, SPO-2025APR/8/S, SPO-2026APR/7/S, SPO-2404

    Part Number

    921355592135549213553

    921355292135519213550

    Diameter

    .75

    .62

    .50

    .44.31

    .25

    Page 27Rev 2.2Rev 2.5

    Table Of ContentsMain Index

    For bridge probes use cables C/SC/6 (P/N 9113016) or C/RA/6 (P/N 9113017). For reflection probes use cables CR/SC/6 (P/N 9113429)or CR/RA/6 (P/N 9113430).

  • 8/12/2019 Catalog About Probe

    28/42

    Nortec PowerLinkDetachable Surface Probes

    Detachable Surface Probes

    SLSurface, (SRL if reflection)

    9222161Part Number

    /1KHZ-50KHZFrequency range

    Frequency Range100Hz-2Khz300Hz-10Khz

    100Khz-500Khz400Hz-30Khz500Hz-40Khz1Khz-50Khz

    5Khz-100Khz100Khz-500Khz

    DescriptionSL/100Hz-2Khz/.75SL/300Hz-10Khz/.62

    SL/100Khz-500Khz/.62SL/400Hz-30Khz/.50SL/500Hz-40Khz/.44SL/1Khz-50Khz/.31SL/5Khz-100Khz/.25

    SL/100Khz-500Khz/.25

    Standard Bridge

    Equivalent to Non Detachable SPO Probe

    SPO-565, SPO-1125

    SPO-565ASPO-1402, SPO-1391SPO-1284, SPO-1598

    SPO-2132

    Part Number92221929222193922228292224579222456922216192221969222308

    Standard Reflection

    /.31Diameter

    Diameter.75.62.62.50.44.31.25.25

    Frequency Range

    100Hz-5Khz100Hz-20Khz300Hz-40Khz

    400Hz-60Khz700Hz-80Khz2Khz-200Khz

    Description

    SRL/100Hz-5Khz/.75SRL/100Hz-20Khz/.62SRL/300Hz-40Khz/.50

    SRL/500Hz-60Khz/.44SRL/700Hz-80Khz/.31SRL/2Khz-200Khz/.25

    Equivalent to Non Detachable Alcoprobe andSPO ProbesAPS/20/S

    APG/16/S, SPO-2134APB/12.5/S, SPO-2136

    APBK/10.5/S, SPO-2025APR/8/S, SPO-2026APR/7/S, SPO-2404

    Part Number

    922245892221609222198

    922219992222009222201

    Diameter

    .75

    .62

    .50

    .44.31

    .25

    Page 28 Rev 2.2Rev 2.5

    NortecPowerLinkDetachable Surface Probes

    Detachable surface probes are available in a variety of diameters and frequency ranges. They are

    shielded to provide maximum sensitivity and are used for crack detection as well as thicknessmeasurement. Other applications include conductivity and coating thickness measurements. Commoncable compatibility among most PowerLink eddy current probes allows one cable to operate probes ineither bridge or reflection configuration. All Nortec PowerLink eddy current probes are backwardcompatible to Nortec NDT-19 and NDT-24 instruments. Cables CL/SC/6 for Nortec 2000 series andC/SC/6 7P for NDT-19 and NDT-24 instruments, are sold seperately.

    NortecPowerLink Detachable Surface Probes

    How to Order:

    Provide part number, description.

    Example:

    Table Of ContentsMain Index

    Probes use CL/SC/6 cable (P/N 9122083).

  • 8/12/2019 Catalog About Probe

    29/42

    I.D.

    O.D.

    NortecStandard Ring/ Donut Probes (SPO Series)

    Ring/ Donut (encircling) probes are made to fit various fastener head diameters. They are mostly used for

    subsurface crack detection with the fastener in place. These probes are supplied with a built-in smalldiameter low noise cable. They are available in both bridge or reflection configurations.

    Probes will be supplied with Nortec 8 pin Burndy connector unless otherwise specified. Other sizes andfrequencies are available to meet specific requirements. Contact the Sensors department at StaveleyInstruments for more details.

    How to Order:

    Provide part number, description.

    Example:

    NortecStandard Ring/ Donut Probes (SPO Series)

    Ring/ Donut Probes

    SPO-996 Ring/ Donut ProbeSPO Number

    9203307Part Number

    Frequency Range500Hz-5Khz100Hz-1Khz100Hz-1Khz100Hz-1Khz100Hz-1Khz200Hz-1Khz200Hz-1Khz100Hz-1Khz100Hz-1Khz100Hz-1Khz100Hz-1Khz100Hz-1Khz100Hz-1Khz100Hz-1Khz100Hz-1Khz100Hz-1Khz100Hz-1Khz

    100Hz-1Khz

    DescriptionSPO-996SPO-1589SPO-1747SPO-731SPO-1746SPO-1074SPO-2352SPO-1745SPO-2733SPO-783SPO-1744SPO-1240SPO-1154SPO-1743SPO-2839SPO-1238SPO-1274

    SPO-2235

    Bridge Ring/ Donut Probes

    Part Number920330792140199214020920295092140219204788*921402392140249214025920295192140269214030*92029559214027921402892033949202956

    9214029

    I.D..30.33.33.34.38.40.42.46.50.50.56.62.62.64.65.75.80

    .87

    O.D..75.831.001.001.00.80.801.001.001.251.151.121.401.151.401.401.40

    1.40

    Reflection Ring/ Donut Probes

    Frequency Range100Hz-10Khz100Hz-10Khz100Hz-10Khz100Hz-10Khz100Hz-10Khz100Hz-10Khz100Hz-10Khz100Hz-10Khz100Hz-10Khz

    DescriptionSPO-2031SPO-2131SPO-2030SPO-2434SPO-2432SPO-2032SPO-2433SPO-2064SPO-2435

    Part Number921670292167039216704921670592167069216707921670892167099216710

    I.D..30.40.50.54.54.62.62.80.87

    O.D..80.801.25.881.151.401.561.401.40

    Page 29Rev 2.2Rev 2.5

    Table Of ContentsMain Index

    * Probes in two halves for limited access area.

  • 8/12/2019 Catalog About Probe

    30/42

  • 8/12/2019 Catalog About Probe

    31/42

    ID

    OD

    NortecDetachable Ring/ Donut Probes

    Ring/ Donut (encircling) probes are made to fit various fastener head diameters. They are mostly used for

    subsurface crack detection with the fastener in place. They are available in both bridge or reflectionconfigurations.

    These probes include a high quality quick release connector. Cables sold separately.

    How to Order:

    Provide part number, description.

    Example:

    NortecDetachable Ring/ Donut Probes

    Frequency Range500Hz-5Khz100Hz-1Khz100Hz-1Khz100Hz-1Khz100Hz-1Khz100Hz-1Khz100Hz-1Khz100Hz-1Khz100Hz-1Khz

    DescriptionR/500Hz-5Khz/.30-.75R/100Hz-1Khz/.33-1.00R/100Hz-1Khz/.34-1.00R/100Hz-1Khz/.50-1.00R/100Hz-1Khz/.50-1.15R/100Hz-1Khz/.56-1.15R/100Hz-1Khz/.62-1.40R/100Hz-1Khz/.75-1.40R/100Hz-1Khz/.80-1.40

    Bridge Ring/ Donut Probes

    Part Number921565092156519215652921565392156549215655921565692156579215658

    I.D..30.33.34.50.50.56.62.75.80

    O.D..751.001.001.001.251.151.401.401.40

    RSurface, (RR if reflection)

    9215653Part Number

    /100HZ-1KHZFrequency range

    /.50Internal Diameter

    1.00External Diameter

    Equivalent to Non-Detachable SPO probesSPO-996SPO-1747SPO-731SPO-2733SPO-783SPO-1744SPO-1154SPO-1238SPO-1274

    Frequency Range100Hz-10Khz100Hz-10Khz100Hz-10Khz

    100Hz-10Khz100Hz-10Khz100Hz-5Khz100Hz-5Khz100Hz-5Khz100Hz-5Khz

    DescriptionRR/100Hz-10Khz/.30-.80RR/100Hz-10Khz/.40-.80RR/100Hz-10Khz/.50-1.25

    RR/100Hz-10Khz/.54-.88RR/100Hz-10Khz/.54-1.15RR/100Hz-5Khz/.62-1.40RR/100Hz-5Khz/.62-1.56RR/100Hz-5Khz/.80-1.40RR/100Hz-5Khz/.87-1.40

    Reflection Ring/ Donut Probes

    Part Number921565992156609215661

    921566292156639215664921566592156669215667

    I.D..30.40.50

    .54

    .54

    .62

    .62

    .80

    .87

    O.D..80.801.25

    .881.151.401.561.401.40

    Equivalent to Alcoprobe or SPO probesARP/8/22P SPO-2031

    ARP/9.5/22P SPO-2131ARP/12.5/31P SPO-2030

    ARP/13.5/24P SPO-2434ARP/13.5/29P SPO-2432ARP/16/36P SPO-2032ARP/16/40P SPO-2333ARP/20/36P SPO-2064ARP/23/36P SPO-2435

    Ring/ Donut Probes

    Page 31Rev 2.5

    Table Of ContentsMain Index

    For bridge probes use cables C/SC/6 (P/N 9113016) or C/RA/6 (P/N 9113017). For reflection probes use cables CR/SC/6 (P/N 9113429)or CR/RA/6 (P/N 9113430).

  • 8/12/2019 Catalog About Probe

    32/42

    ID

    OD

    NortecPowerLinkDetachable Ring/ Donut Probes

    Ring/ Donut (encircling) probes are made to f it various fastener head diameters. They are used mostly for

    subsurface crack detection with the fastener in place. They are available in both bridge or reflectionconfigurations. Common cable compatibility among most PowerLink eddy current probes allows onecable to operate probes in either bridge or reflection configuration. All Nortec PowerLink eddy currentprobes are backward compatible to Nortec NDT-19 and NDT-24 instruments. Cables CL/SC/6 forNortec 2000 series and C/SC/6 7P for NDT-19 and NDT-24 instruments, are sold seperately.

    How to Order:

    Provide part number, description.

    Example:

    Nortec PowerLink Ring/ Donut Probes

    Ring/ Donut Probes

    Frequency Range500Hz-5Khz100Hz-1Khz100Hz-1Khz100Hz-1Khz100Hz-1Khz100Hz-1Khz100Hz-1Khz100Hz-1Khz100Hz-1Khz

    DescriptionRL/500Hz-5Khz/.30-.75RL/100Hz-1Khz/.33-1.00RL/100Hz-1Khz/.34-1.00RL/100Hz-1Khz/.50-1.00RL/100Hz-1Khz/.50-1.25RL/100Hz-1Khz/.56-1.15RL/100Hz-1Khz/.62-1.40RL/100Hz-1Khz/.75-1.40RL/100Hz-1Khz/.80-1.40

    Bridge Ring/ Donut Probes

    Part Number922223392224799222480922248192224829222483922248492224859222486

    I.D..30.33.34.50.50.56.62.75.80

    O.D..751.001.001.001.251.151.401.401.40

    RLSurface, (RRL if reflection)

    9222233Part Number

    /500HZ-5KHZFrequency range

    /.30-Internal Diameter

    .75External Diameter

    Equivalent to Non-Detachable SPO probesSPO-996SPO-1747SPO-731SPO-2733SPO-783SPO-1744SPO-1154SPO-1238SPO-1274

    Frequency Range100Hz-10Khz100Hz-10Khz100Hz-10Khz

    100Hz-10Khz100Hz-10Khz100Hz-5Khz100Hz-5Khz100Hz-5Khz100Hz-5Khz

    DescriptionRRL/100Hz-10Khz/.30-.80RRL/100Hz-10Khz/.40-.80RRL/100Hz-10Khz/.50-1.25

    RRL/100Hz-10Khz/.54-.88RRL/100Hz-10Khz/.54-1.15RRL/100Hz-5Khz/.62-1.40RRL/100Hz-5Khz/.62-1.56RRL/100Hz-5Khz/.80-1.40RRL/100Hz-5Khz/.87-1.40

    Reflection Ring/ Donut Probes

    Part Number922223792224879222238

    922248892224899222490922249192224929222493

    I.D..30.40.50

    .54

    .54

    .62

    .62

    .80

    .87

    O.D..80.801.25

    .881.151.401.561.401.40

    Equivalent to Alcoprobe or SPO probesARP/8/22P SPO-2031

    ARP/9.5/22P SPO-2131ARP/12.5/31P SPO-2030

    ARP/13.5/24P SPO-2434ARP/13.5/29P SPO-2432ARP/16/36P SPO-2032ARP/16/40P SPO-2333ARP/20/36P SPO-2064ARP/23/36P SPO-2435

    Page 32 Rev 2.2Rev 2.5

    Table Of ContentsMain Index

    Other sizes and frequencies are available to meet specific requirements. Contact the Sensors department at Staveley Instruments for more details.Probes use CL/SC/6 cable (9122083).

  • 8/12/2019 Catalog About Probe

    33/42

    NORTEC

    SPO-1958

    NORTEC

    SPO-1994

    NORTEC

    SPO-3806

    NORTEC

    SPO-2664

    NortecStandard Sliding Probes

    Fixed and adjustable types are available. Operating in the reflection mode, they allow inspection of

    fastener rows for surface and subsurface cracks. Sliding probes are directionally sensitive and featureengraved green lines to assist scan orientation to the expected direction of the cracks. Fixed types aremostly used in riveted joints to detect cracks emanating from holes. Penetration is sufficient for fuselagethickness up to.15 (4mm). Adjustable types are used for thicker structures up to .75 (19mm). Theyoperate satisfactorily with various fasteners including magnetic types.

    How to Order:

    Provide part number, description.

    Example:

    NortecStandard Sliding Probes

    SPO NumberSPO-2210

    SPO-3806

    SPO-3993

    SPO-2664

    Cable TypeMicrodot (Dual)

    CR/SC/6(Detachable)

    CR/SC/6(Detachable)

    CR/SC/6(Detachable)

    Fixed Types

    Part Number9206409

    9211636

    9216183

    9222060

    SPO-3806Description

    9211636Part Number

    ApplicationFor surface cracks and second layer near surfacecracks.

    For surface and second layer cracks.

    Same as SPO-3806 but will accept larger fastenerheads.

    For surface cracks and second layer near surfacecracks.

    Frequency Range1Khz-100Khz

    1Khz-100Khz

    1Khz-100Khz

    1Khz-100Khz

    Probe Size

    L x W x H1.5 x .5 x 1.0

    1.5 x .8 x 1.0

    1.7 x 1.0 x 1.2

    1.5 x .5 x 1.0

    SPO NumberSPO-1958

    SPO-1994

    SPO-1957

    Cable TypeMicrodot (Dual)

    Microdot (Dual)

    Microdot (Dual)

    Adjustable Types

    Part Number9206405

    9206406

    9206404

    ApplicationPenetration up to .5

    Penetration up to .5

    Penetration up to .7

    Frequency Range100Hz-50Khz

    100Hz-20Khz

    100Hz-10Khz

    Probe SizeL x W x H

    1.8 x 1.0 x .7

    2.3 x 1.0 x .8

    2.8 x 1.3 x .9

    CableFor Microdot type

    For Microdot type(right angle)

    Part Number9116184

    9116185

    DescriptionSPO-2182

    SPO-4139

    CableFor detachable type

    For detachable type(right angle)

    Part Number9113429

    9113430

    DescriptionCR/SC/6

    CR/RA/6

    Sliding Probes

    Fixed type Adjustable type

    Page 33Rev 2.2Rev 2.5

    Table Of ContentsMain Index

  • 8/12/2019 Catalog About Probe

    34/42

    NORTEC

    SPO-1958L

    NORTEC

    SPO-1994L

    NORTEC

    SPO-3806L

    NORTEC

    SPO-2664L

    Fixed type Adjustable type

    NortecPowerLink Sliding Probes

    Fixed and adjustable types are available. Operating in the reflection mode, they allow inspection of

    fastener rows for surface and subsurface cracks. Sliding probes are directionally sensitive and featureengraved green lines to assist scan orientation to the expected direction of the cracks. Fixed types aremostly used in riveted joints to detect cracks emanating from holes. Penetration is sufficient forfuselage thickness up to.15 (4mm). Adjustable types are used for thicker structures upto .75 (19mm). They operate satisfactorily with various fasteners including magnetic types.

    How to Order:

    Provide part number, description.

    Example:

    Sliding Probes

    SPO NumberSPO-2210L

    SPO-3806L

    SPO-3993L

    SPO-2664L

    Cable Type16 pin to MDs

    CL/SC/6

    CL/SC/6

    CL/SC/6

    Fixed Types

    Part Number9222241

    9222242

    9222243

    9230101

    SPO-3806LDescription

    9222242Part Number

    ApplicationFor surface cracks and second layer near surfacecracks.

    For surface and second layer cracks.

    Same as SPO-3806 but will accept larger fastenerheads.

    For surface cracks and second layer near surfacecracks.

    Frequency Range1Khz-100Khz

    1Khz-100Khz

    1Khz-100Khz

    1Khz-100Khz

    Probe Size

    L x W x H1.5 x .5 x 1.0

    1.5 x .8 x 1.0

    1.7 x 1.0 x 1.2

    1.5 x .5 x 1.0

    SPO NumberSPO-1958L

    SPO-1994L

    SPO-1957L

    Cable Type16 pin to MDs

    16 pin to MDs

    16 pin to MDs

    Adjustable Types

    Part Number9222244

    9222245

    9222246

    ApplicationPenetration up to .5

    Penetration up to .5

    Penetration up to .7

    Frequency Range100Hz-50Khz

    100Hz-20Khz

    100Hz-10Khz

    Probe SizeL x W x H

    1.8 x 1.0 x .7

    2.3 x 1.0 x .8

    2.8 x 1.3 x .9

    Cable

    16 pin to MDs

    Part Number

    9122096

    Description

    16 pin Lemo to 3 pin and micro-dot PowerLink

    Cable

    CL/SC/6

    Part Number

    9122083

    Description

    16 pin Lemo to 7 pin Lemo

    Page 34 Rev 2.2Rev 2.5

    NortecPowerLink Sliding Probes

    Table Of ContentsMain Index

  • 8/12/2019 Catalog About Probe

    35/42

    NortecStandard Conductivity Probes

    Conductivity probes are designed for sorting metals and aluminum

    alloys, determining heat-treatment condition or damage. Theseprobes were developed for Nortec conductivity instruments. Standardfrequency of the probes for the NDT-5 and 5A is 100 KHz (60 KHzmanufactured at customer request).

    These probes are supplied only with connectors for the instrumentsspecified, and are not interchangeable with other instruments.

    Probes require instrument to be calibrated by Staveley InstrumentsService Department for accurate operation.

    How to Order:

    Provide part number, type and frequency.

    Example:

    NortecStandard Conductivity Probes

    Conductivity Probes

    Part Number92029329202935*9216635

    Diameter.75.75.31

    For Use with NDT-5 (8% to 110% IACS)

    Probe3049A3049E

    SPO-3897

    Frequency100KHZ100KHZ100KHZ

    Length2.752.752.75

    3049AType

    9202932Part Number

    100KhzFrequency

    Part Number92029339202934*9216634

    Diameter.75.75.31

    For Use with NDT-5A (26% to 65% IACS)

    Probe3049C3049D

    SPO-887

    Frequency100KHZ100KHZ100KHZ

    Length2.752.752.75

    Part Number9206106(1)9206414(2)

    Diameter.75.31

    For Use with NDT-17 (24% to 65% IACS)

    ProbeSPO-2460SPO-1688

    Frequency60KHZ60KHZ

    Length1.002.75

    (1) Probe includes LED, (2) Probe does not include LED.

    Page 35Rev 2.2Rev 2.5

    Table Of ContentsMain Index

    *Heavy Duty Cable

  • 8/12/2019 Catalog About Probe

    36/42

    NortecPowerLink Conductivity Probes

    Nortec PowerLink conductivity probes are designed to be used with Nortec 1700, 2000, 3000,

    and WorkStation instruments. They are designed for sorting metals and aluminum alloys, determiningheat-treatment condition or damage. Standard frequencies of the probes is 60 Khz and 480 Khz.

    These probes are supplied with a 16 pin Lemo connector and are not interchangeable with otherinstruments.

    How to Order:

    Provide part number, type and frequency.

    Example:

    NortecPowerLink Conductivity Probes

    Conductivity Probes

    Lt. Wt. Conductivity probeType

    9222340Part Number

    Part Number

    9222340

    9222341*

    9222360

    9222361*

    Diameter

    .75

    .75

    .31

    .31

    For Use with N1700, 2000, 3000 and WorkStation (8% to 110% IACS)

    Descripiton

    Lt. Wt. 60KhzConductivity probe

    Lt. Wt. 480KhzConductivity probe

    SPO-887L 60KhzConductivity probe

    SPO-887L 480KhzConductivity probe

    Frequency

    60Khz

    480Khz

    60Khz

    480Khz

    Height

    1.0

    1.0

    2.75

    2.75

    60KhzFrequency

    60 Khz Lt. Wt. Conductivity Probe

    Page 36 Rev 2.2Rev 2.5

    Table Of ContentsMain Index

    * Not for use with N3000 instrument.

  • 8/12/2019 Catalog About Probe

    37/42

  • 8/12/2019 Catalog About Probe

    38/42

    OD Probes

    NortecOD Probes

    These probes have encircling type coils to surround rods or tubes. OD

    probes are available in three different coil configurations.

    1) Absolute style These detect changes in conductivity and are alsoused in monitoring the heat treating process. The absolute coil can alsobe used to monitor wall thickness to detect thinning in tube walls.

    2) Differential style Primarily used for pit and crack detection.

    3) Switchable These can be used in either mode.

    OD coils are manufactured with long wearing stainless steel faceplates.Standard probe hole sizes range from .015 to 1.50. Due to the widevariety of sizes and frequencies, OD coils are manufactured to customerspecifications when ordered.

    NortecOD Probes

    How to order

    Example:

    OD(1)Probe Type

    /10KhzFrequency

    /.525Actual Probe Diameter(2)

    ACoil Type

    Absolute-(A)Differential-(D)Switchable-(S)

    (1) To order the PowerLink version of this probe order as ODL

    (2) The amount of clearance needed is dictated by the frequency and material to be inspected. If you are unsureplease contact the Sensors Department at Staveley Instruments for more details.

    Probes are manufactured for easy mounting. Probe size, L=3.0 x W=1.2 x H=3.1.

    The standard probes are fitted with a detachable Lemo triaxle connector. PowerLink probes will be fitted with a7 pin Lemo connector. Cables are sold seperately. For standard probes (Lemo triaxle) use the standard detachablecable C/SC/6 (P/N 9113016).

    For PowerLink probes use the detachable cable CL/SC/6 (P/N 9122083).

    Page 38 Rev 2.2Rev 2.5

    Table Of ContentsMain Index

  • 8/12/2019 Catalog About Probe

    39/42

    General Purpose Probe Kits

    General Purpose Kits

    The Nortec probe kits contain five of our most widely used probes, an aluminum crack standard and a block of

    six conductivity samples. The kits are available in either the standard probe series with integral 6 cables with8 pin Burndy connectors, or the detachable series with a C/SC/6 cable included (8 pin Burndy)

    Detachable Training Kit

    This kit contains two surface probes (covering a wide frequency range), two pencil and two bolt hole probes(absolute and differential), one right angle pencil probe, two detachable bridge cables (straight and right angle),and one SPO-3806 sliding reflection probe with cable. Also included are a set of plastic shim stocks, analuminum crack standard, a thinning standard, a second layer crack standard, a TB-16 hole standard, and one setof six conductivity samples. This kit is available with Detachable Probes only.

    How to Order

    Provide part number and description

    Example: 9216632 Standard Probe Kit

    Standard Probe Kit Stock Part No. 9216632Includes: 1)9204899 SP-10A 10 KHz Surface Probe

    1)9204903 SP-100 100KHz Surface Probe1)9204905 SP-500 500KHz Surface Probe1)9204915 3551F 500KHz Pencil Probe1)9213428 3551DF 2 MHz Pencil Probe1)1902474 Set of Six Conductivity Samples1)1902510 TB-SI Aluminum Crack Standard

    Carrying Case

    Detachable Probe Kit Stock Part No. 9216633Includes: 1)9213011 S/300KHz-10KHz/.62 Surface Probe

    1)9213012 S/1 KHz-50KHz/.31 Surface Probe1)9213013 P/100KHz-500KHz/A/90.5/6 Right Angle

    Pencil probe1)9213014 P/500KHz-1MHz/A Pencil Probe1)9213015 P/500KHz-2MHz/D Pencil Probe1)9113016 C/SC/6 6 Cable Straight Connector1)1902474 Set of Six Conductivity Samples1)1902510 TB-S1 Aluminum Crack Standard

    Carrying Case

    Detachable Training Kit - Stock Part No. 9216655Includes: 1)9213011 S/300KHz-10KHz/.62 Surface Probe

    1)9213012 S/1KHz-50KHz/.31 Surface Probe1)9213013 P/100KHz-500KHz/A/90.5/6 Right Angle

    Pencil probe1)9213014 P/500KHz-1MHz/A Pencil Probe1)9213015 P/500KHz-2MHz-D Pencil Probe1)9113016 C/SC/6 6 Cable Straight Connector

    1)1902474 Set of Six Conductivity Samples1)1902510 TB-SI Aluminum Crack Standard1)5319540 Set of Plastic Shims1)1902477 TB-16 Hole Standard1)9216156 B/100KHz-500KHz/A.250 Bolt Hole Probe1)9216171 B/500KHz-2MHz/D.250 Bolt Hole Probe1)9113017 C/RA/6 6 Cable Right Angle Connector1)9211636 SPO-3806 Sliding Probe1)1916914 SPO-4304 Thinning Sample .039 to .1641)1916915 SPO-3932 Second Layer Crack Standard

    (1/16 on 1/16 Aluminum w/fasteners)Carrying Case

    Probe Kit 9216632

    Page 39Rev 2.2Rev 2.5

    Table Of ContentsMain Index

  • 8/12/2019 Catalog About Probe

    40/42

    Documentation

    Probe Documentation

    A Test Documentation Form is supplied with all standard Eddy Current Probes. Each probe is tested on a sample

    or standard relevant to the probe diameter and frequency, for proper signal response. In addition a Certificate ofConformanceis available upon request.

    Page 40 Rev 2.2Rev 2.5

    Table Of ContentsMain Index

  • 8/12/2019 Catalog About Probe

    41/42

    Special Product Requests

    You may mail your request to: Staveley Instruments, Inc. , 421 N. Quay St., Kennewick WA 99336You may fax your request to: (509) 735-4672 or e-mail your request to: [email protected]

    Contact Information:

    Name:__________________________________

    Company:_______________________________

    Address:____________________________________________________________________________________________________________________________________

    Telephone: (______)_______________________

    Fax: (______)____________________________

    E-mail: _________________________________

    Is there a similar probe to the one you require in the probe catalog? Yes No (CHECK ONE)If yes please indicate page number and part number ifapplicable,___________________________________________

    If there is a similar probe in this catalog what alterations would you require?____________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________

    Type of flaw:

    Material to be tested:______________________________________________________________________

    Is the flaw located on the surface, subsurface or both?_______________________

    Depth of penetration required?_______________ What is the typical flaw size (L X W X D*)? _________________

    What is the maximum flaw size to be detected (L X W X D*)?_______________________________

    What is the orientation of the flaw?

    *L= lengthW= widthD= depth

    Instrument or connection:

    What instrument do you wish this probe to connect with (CHECK ONE)?

    Nortec 1000 PowerStation

    Nortec 2000S, 2000D Nortec 19e, 19eII

    Nortec 3000 Nortec 24

    WorkStation Other

    If other please specify:

    Page 41Rev 2.4

    Table Of ContentsMain Index

  • 8/12/2019 Catalog About Probe

    42/42

    Special Product Requests

    What type of probe would you like to use (CHECK AS MANY AS APPLY)?

    Absolute Pencil probe Other

    Differential Surface probe

    Bridge I/D probe

    Reflection O/D probe

    Use the area below to sketch your requirements.

    Table Of ContentsMain Index