Upload
ehab8320014413
View
129
Download
7
Embed Size (px)
DESCRIPTION
heater cataloge 7.5 kw and higher
Citation preview
www.cetal.com
Heating elements according to specification
Duplicate-moulded / cast elements
Screw on immersion heaters
Flange immersion heaters
Process circulation heaters
Power control panels
Equipment for hazardous atmospheres
Boron Nitrid VHP heating rods
Designs and manufactures your industrial heating elements and heating systems
Die heating/bolt heaters
• food industries • hydraulic power plant • nuclear power plant • heavy fuel oil power plant • fuel gas compressor • printing house • iron and steel industry • research laboratories • maintenance in temperature of fuel tank located outside • drilling platform • refinery • heating of hazardous premises •2
page 2 Table of conTenTs
page 3 THe coMpanY
page 5 DeTerMining HeaT energY requireMenTs
proDucT applicaTionspage 6
page 7 inDusTrial MarKeT secTors
uniT eleMenTs anD asseMblies/general & TecHnical inforMaTionspages 8-10
pages 11-12 HeaTing eleMenTs accorDing To specificaTions
eleMenTs forMeD To TeMplaTes / DuplicaTe-MoulDeD/casTeD eleMenTs / infrareD generaTors
page 13
screW on iMMersion/ Movable HeaTerspages 14-15
pages 16-17 flange iMMersion HeaTers
process circulaTion HeaTers / poWer conTrol panelspage 18
page 19 ribbeD HeaTing eleMenTs / inDusTrial air DucT HeaTers (eex)
page 4 cerTificaTions / proDucTs conTrols
Die HeaTing/bolT HeaTerpages 26-27
equipMenTs for HazarDous aTMospHerespages 20-23
boron niTriD vHp roDspages 24-25
soMMarY
• food industries • hydraulic power plant • nuclear power plant • heavy fuel oil power plant • fuel gas compressor • printing house • iron and steel industry • research laboratories • maintenance in temperature of fuel tank located outside • drilling platform • refinery • heating of hazardous premises • 3www.cetal.com
THe coMpanY
CETAL, Constructions ElectroThermi-ques d’Alsace, was set up in 1967 as a family business. Over the years, the
company has specialized in designing and manufacturing industrial heating assemblies and elements for heating
liquids, solids, gases and premises in hazardous atmospheres and non hazardous atmospheres.
The experience and competence of our engineering department and our high performance equipment enable us to offer a large range of electrothermical equipment (supply and maintenance). The company’s know-how and high quality products have strongly contributed to the development of its reputation in
France and abroad. CETAL now operates in Europe and the world via an agent network. CETAL success is also built on its human assets, our customers can rely on the dynamism and experience of our personnel to assist them in finding the right diagnosis for their expectations at all times.
benefiTs of ceTal
CERTIFIED QUALITY AND ENVIRONMENTAL
MANAGEMENT SYSTEMS
CETAL develops its quality management system via an Ishikawa diagram (Manpower, Methods, Machines, Material, Environnement). Thanks to the continuous improvment of these five key areas, the implementa-tion of efficient method and tool (5S-PDCA), CETAL assure the best quality and added value to its customers. Concerning envi-ronmental management, CETAL develops and maintains the appropriate policy and tools :- to comply with the rules and
ICPE nomenclature associated to the protection of the environ-ment regulation.
- to master energy and raw mate-rial consumption
- to optimize wastes manage-ment and valorization
QUALIFIED, DYNAMIC & FORTHCOMING TEAMS
BY YOUR SIDE
The target of our technical sales agent, in close link with purcha-sing, enginering and manufactu-ring is to understand and satisfy customers expectations.A solid network of sales agents continiously uptade to CETAL’s products help you define your requirements and find the appro-priate solutions.Trained, qualified and certified manufacturing operators and technicians guarantee that pro-ducts and services are delive-red with the highest level of quality and that environmental standards have been respected all through the manufacturing process.
PARTNERSHIPS WITH SUPPLIERS AND
SUBCONTRACTORS
CETAL develops strong, durable and effective partnerships with best suppliers and subcontrac-tors.CETAL involves its partners in the process of developing and maintaining a flexible, reactive and quick-to-adapt supply chain to meet your requirements in terms of quality, cost and deli-very.
FLEXIBILITY AND EFFECTIVENESS OF
PROCESSES
CETAL develops, maintains and improves specific production management tools (CAM, confi-gurator) so as to deliver, in time, tailor-made products.Furthermore, these tools ensure that traceability is maintained through the entire manufactu-ring process for each family of products and that optimum use of human and material resour-ces is planned and achieved. To provide appropriate solutions to its customers, CETAL, via a flexible organization and versa-tile teams, continuously impro-ves its manufacturing proces-ses (unitmanufacturing, small and average series, just-in time manufacturing) and its control process (unit electrical and unit mechanical controls).
PRODUCTS & SERVICES IMPROVEMENT AND
INNOVATION
The competitive monitoring, technological intelligence and regulation watch enables CETAL to understand and anticipate market and customer require-ments evolution. An omnipresent QDC approach: Quality - Delivery - Cost enables CETAL to propose the best products and services.
CERTIFIED QUALITY AND ENVIRONNEMENTAL MANAGEMENT SYSTEMS
FLEXIBILITY AND EFFECTIVENESS OF PROCESSES
PRODUCTS & SERVICES IMPROVEMENT AND INNOVATION
PARTNERSHIPS WITH SUPPLIERS AND SUBCONTRACTORS
QUALIFIED, DYNAMIC & FORTHCOMING
TEAMS BY YOUR SIDE
5 reasons To cHoose ceTal
CUSTOMER
• food industries • hydraulic power plant • nuclear power plant • heavy fuel oil power plant • fuel gas compressor • printing house • iron and steel industry • research laboratories • maintenance in temperature of fuel tank located outside • drilling platform • refinery • heating of hazardous premises •4
All our products undergo individual inspections at the end of the manufacturing line. Their dimensions, mechanical and electrical characteristics are checked according to standard NFC 79-620. In addition, each subcomponent element of our products is subjected to cold testing.
Circuit power tested by cold resistance measurements. Allowed tolerance : -5% and +10% of the nominal resistance value
Testing of insulation between live parts and the earth.The test is conducted under a direct voltage of 500 V. The minimum cold values upon release from the company are higher than 100 Megohms.
Testing of dielectric insulation between live parts and the earth.The test is conducted under an effective alternative voltage which is equal to twice the nominal voltage plus 1000 V.No warping or perforation must be found during the test.
Reading of the nominal operating temperature. (on request)The stray current and the hot dielectric rigidity can be measured on a sample.
Specific conditions of use (total power number of circuits in the assembly temperature) may lead to stray current values which require special measures.
MecHanical inspecTionsNon destructive test
Visual inspections of heating elements.
Weld tightness inspections : in hydraulic chambers with a maximum diameter of DN 700 or 28 in. and maximum pressure equal to 40 bars helium tightness test with mass spectrometer dye penetrant testing
X-ray inspections of welds where applicable.
cerTificaTions
proDucTs conTrols
DiMensional inspecTionsThe tolerances are adapted to the intended use and are specified on the manufacturing drawings.
noTificaTionLCIE 02 ATEX Q 8022APAVE - DESP
Hazardous atmosphere :CETAL designs and manufactures hea-ting elements and assemblies accor-ding to specifications for hazardous atmospheres in compliance with the fol-lowing harmonized European standards CENELEC/CEI : EN60079-0 (2004 general requirements), EN60079-1 (2004 flameproof enclosure «d»), EN60079-7 (2003 increased safety «e») and EN 50020 (PR60079-11) (intrinsic safety «i»). All products are controlled and approved (conformity certificate by LCIE, certified body).Our company manufactures equipment in accordance with ATEX (94/09/EC). The products have fully satisfied the
type examination and test requirements of the standards. The EC type examina-tion certificates are delivered by an ap-proved certificate body (LCIE N° 0081).
Equipments under pressure :Heating elements integrated in equip-ment under pressure are manufactured in accordance with the PED 93/23/EC. Different moduls (A, AI,B1+F) are imple-mented according to the risk category (I - II or III). The conformity certifica-tion is done by a notified body (APAVE N° 0060).
CE - CSA LR78605UL LE 1878325PDNV Marine
The products manufactured for the Eu-ropean market are CE marked and meet the requirement of all European Directi-ves which are applicable.CETAL’s products are approved by the Canadian Standard Association
(CSA-0-M 91/72-M19 84-465-465A-465B).Some products have been subjected to certification in accordance with UL standards (explosion proof industrial convectors).
abiliTY/MarKing
ISO 9001 (v. 2000) QUA/1994/21170 ISO 14001 ENV/2002/18281
Quality Company’s spirit, is for CETAL one of the determinant vector of its development. The company is certified ISO 9001 since 1994; it anticipated the certification of the management sys-tem ISO 9001 (revision 2000). Aware of the importance of a sustainable de-velopment, CETAL integrates it into its strategy. The implementation of continuous improvement drastically in-
crease customer’s satisfaction. CETAL operates according to standards ISO 9001 V 2000, and in compliance with the European Directives 73/23/EC (Low Voltage), 89/336/EC (EMC), 94/09/EC (ATEX), 97/23/EC (PED) and the modi-fied Directives.
cerTificaTion
QMOS - QS - EN - ASME - TÜV Our welding operations are EN-ASME or body certified. Our welders are qualified by an independent organism. CETAL designs and manufactures the
equipments in accordance with CODAP-ASME VII division I, API …codes.
qualificaTion
elecTrical inspecTions
• food industries • hydraulic power plant • nuclear power plant • heavy fuel oil power plant • fuel gas compressor • printing house • iron and steel industry • research laboratories • maintenance in temperature of fuel tank located outside • drilling platform • refinery • heating of hazardous premises • 5www.cetal.com
HeaTing gases
poWer calculaTion
HeaTing liquiDs
HeaTing soliDs
1. Open tank heating2. Bottom tank heating3. Side tank heating4. Cosed tank heating5. Circulation heater6. Tube heating7. Water bath8. Liner heating for
fuel oil tank
1. Air drying2. Air duct heater3. Circulation heaters4 et 5. Radiators
Heat requiredfor process start-up :
Qabsorbed
+Qlost
+CS = Q
start-up(joules) +
Power required for process start-up to maintain process operation
Pstart-up
= Q
start-up
Tstart-up
P
operation=
Qoperation
Tprocess
+Q
lost start-up= 1
SC = %(Q absorbed
+ Q lost
)
Q absorbed
= m x Cp x ∆θ + m x Lf,v
P absorbed
= Dm x Cp x ∆θ + Dm x Lf,vDm = mass flow rate (Kg/second)Cp = specific heat (J/Kg x °C)
∆θ = temperature rise
Lf,v = latent heat of fusion/vap. (J/Kg)
ρ = density (Kg/m³)
Dv = volume flow rate (Kg/s)
Dm = ∆m
∆T =ρ
∆V
∆T =ρ Dv
2 x S x P x T
start-up
to maintain process or operation
Qabsorbed
+Qlost
+CS = Q
operation(joules)
m = heated massCp = specific heat (J/Kg x °C)
∆θ = temperature rise
Lf,v = latent heat of fusion/vap. (J/Kg)
CS = safety cœfficient : usual value 20%
Qlost operation
= S x P x Tprocess
S =exposedsurface(m²)P=surfacelossesatfinaltemperature(W/m²)T=risetime
Example : Case of an industrial process designed to obtain the paraffin casting of steel machined parts (100 g) before shipping. 20 elements are placed in steel basket (2,5 kg) and are dipped in a paraffin bath at 70° C during 5 minutes.The start-up phase of the process requires that 100 kg of solids paraffin are heated from 20° C to 70° C on a period of 4 hours. During process operation, 15 kg of paraffin are added every hour.
Material characteritics :Steel : Cp = 500 J/Kg°CTank :
mass = 100Kg dimensions = 500 x 400 x 300 mm
Paraffin : Cp = 2800 J/Kg°CLatent heat of fusion = 146 KJ/Kg
Surface losses to 70°C :Paraffin surface losses = 750W/m²Tank walls losses = 400W/m²
= 24,7 x 106 J
100 x 2800 x (56-20)
100 x 146+
100 x 2800 x (70-56)
+Qabsorbed
=paraffin
Qabsorbed
=tank 100 x 500 x (70-20)
=2,5 x 106 J
CS = 20%(Qabsorbed
+Qlost
)=6 x 106J
Power required : for process start-up.
= 3,2 x 106 J
Q lost = 0,2 x 750 x 4 x 3600
0,74 x 400 x 4 x 3600
+1 x 2
1 x 2
Pdem
= (Qabsorbed
+Qlost(
+CS) Tdem
(27,2+3,2+6) x 106
4 x 3600= 2,5 kW=
Pfonct
= (Qabsorbed
+Qlost
+CS) Tprocess
(5+6,4+2,3) x 106
1 x 3600= 3,8 kW=
forprocessoperation.
= 3,7 x 106 J
(12x2,5)+(240x0,1) 500 x (70-20)
=�1,35�x106�J
15 x 2800 x (56-20)
15 x 146+
15 x 2800 x (70-56)
+=
0,2 x 750 x 4 x 3600
0,74 x 400 x 4 x 3600
+1 x 2
1 x 2
=6,4 x 106 J
= 20%(Qabsorbed
+Qlost
) =2,3 x 106J
=
=
Example : Case of a stainless steel 321 open tank heater, weighting 150 kg, and whose dimensions are 1m x 1 m x 0,8m. The tank is filled with water up to 0,7m. The walls and buttom of the tank are insulated with a 0,1 m thick material. The water is heated in one hour from 10° C to 80° C at the start-up of the process. Afterwards, 70 liters of hot water are removed every hour, and replaced by an equal volume at 10° C.
Material characteritics :Cp steel = 500 J/Kg°C
ρwater = 1000Kg /m³
Cf water = 4185 J/Kg°CInsulation and surface losses :
Exposed water surfaces = 8kW/m² at 80°CInsulated surface = 80W/m² at 80°C
forprocessoperation.
= 20,5 x 106 J 70 x 4185 x (80-10)
= (205+5,25)x106 J 700 x 4185 x (80-10)
150 x 500 x (80-10)
=+Qabsorbed
=
Power required : for process start-up.
Qlost
=
= (14,4 + 0,55) x 106 J
1 x 8000 x 3600
3,8 x 80 x 3600
+1 x 2
1 x 2
CS = 20%(Qabsorbed
+Qlost
)
=
=45,04x 106J
Pdem
= (Qabsorbed
+Qlost
+CS)
(210,25+14,95+45,04) x 106
1 x 3600= 75 kW=
Tdem
Pfonct
= (Qabsorbed
+Qlost
+CS)
(20,5+29,9+10,08) x 106
1 x 3600= 16,8 kW=
Tdem
1 x 8000 x 3600
3,8 x 80 x 3600
+
= (28,8 + 1,1) x 106 J
= 20%(Qabsorbed
+Qlost
) =10,08x 106J
Example : Case of drying process that must be supplied continuously with hot air at a temperature of 200° C, with a flow rate of 100m³/min, and with an absolute pressure of 3 bars. At the imput of the duct heater, the air temperature is 100° C. A further 3m distance will be traveled by the heated air at the exit of the heater before reaching the process. The dimensions of the air duct heater are the following : section 600 mm x 600 mm, thickness of insulation = 60 mm Density of air at 3 bars and 100°C :
ρ air =
ρ air x
3bars,100° C 1bar,0° C273 x Pabsolue
273 + θi = 1275 x
273 x 3273 + 100
= 2799 Kg/m³
Mass of air heated per hour = mass flow rate100m³/mn x 2,799Kg/m³x60mn/h=16794 Kg/h
= 20%(475+0,72)=95kW
Exchange surface heater/ambient medium :4x0,6x3 = 7,2m²
Isolation surface losses :isolated surface ˜ 100W/m² at 200°C
Material characteritics :Cf air = 1020 J/Kg°C
ρ air = 1275 Kg/m³1bar,0° C
Power required for process operation.
= 1711x106 J/h = 475kW 16794 x 1020 x (200-100)
Pabsorbed
=
= 0,72kW 7,2 x 100 Plost
=
CS = 20%(Pabsorbed
+Plost
)
Pfonct
= Pabsorbed
+Plost
+CS
= 475+0,72+95=570kW
DaTa
1. Drying stove2. Heating tunnel3. Immersion heating4. Heating plate5. Form heating
case : heated fluid, forced circulation
1
1
23
4 5
2
4
5
3
6 7 8
1
2 3
4 5
• food industries • hydraulic power plant • nuclear power plant • heavy fuel oil power plant • fuel gas compressor • printing house • iron and steel industry • research laboratories • maintenance in temperature of fuel tank located outside • drilling platform • refinery • heating of hazardous premises •6
proDucT applicaTions
soliDsSOLIDS Cp (KJ/Kg.K)
Aluminium 0,91Cooper 0,39Cast iron 0,50Brass 0,39Asphalt 1,63Plastics 0,84 to 2,26Paraffin 3,26
LIQUIDS Cp (KJ/Kg.K) LIQUIDS Cp (KJ/Kg.K)Acetone 2,22 Heat transfer fluids 1,55 to 2,00Acetic acid 2,13 Freon 12 0,97Hydrochloric acid 2,51 Glycerine 2,43Formic acid 1,63 Naphta oil 2,09Nitric acid 2,76 Paraffin oil 2,18Sulphuric acid 1,38 Industrial oils 1,75 to 1,80 Ethyl alcohol 2,85 Milk 3,77Ammonia (liquid) 4,60 Mercury 0,14Benzene 1,88 Perchlorethylene 0,88Beer 4,19 Gasoline 2,09Bromine 0,46 Phenol 2,34Chloroform 0,96 Carbon sulphide 0,96Methylene chloride 2,51 Carbon tetrachloride 0,88Water 4,19 Toluene 1,76Sea water 4,00 Trichlorethylene 0,96Glycol water 35 % 3,88 Glass 0,84Turpentine 1,76 Wine 3,77Ether 2,26 Vinegar 3,85Ethylene glycol 2,32 Liquid hydrocarbons -Fuel oil 1,72 to 2,22 Dyes (drying) -
GASES Cp (KJ/Kg.K) GASES Cp (KJ/Kg.K)Air 1,01 Natural gas 2,51Ammonia 2,09 Hélium 5,19Nitrogene 1,04 Hydrogen 14,34Butane 1,66 Methane 2,24Chlorate gas 0,48 Oxygen 0,91Carbon dioxide 0,85 Ozone 0,82Sulfure dioxide 0,61 Propane 1,70Ethane 1,77 Steam (100° C) 2,01
6 ATEX, 12’’ flange immersion heaters in series (6x72,5 kW) Fluid : hydrogenated wax at 325° C
331 kW, 16’’ flange circulation heater for gas re-fining at 290° C
320 kW, 380 V, 12’’ flange Skid according to ASME sect. VII, division 1 et SQL.Fluid : thermal oil
488 kW, 16’’ flange, ATEXCirculation heater forcatalytic unit 534°C.
435 kW, ATEXCirculation heater Fluid : wax at 325° C
57 kW, 6’’ flangeCirculation heaterFluid : glycol waterPharmaceutical sector
600 kW, 400 V 3Ph.Circulation heaters equipped with 17 x 35 kW THP elementsFluid : heat transfer oilAeronautic sector
Hot air generator. Power 145 kW/380 V.Flow rate 1730 Nm3/h.input/output temperatures7/200°C.
liquiDs
gases
• food industries • hydraulic power plant • nuclear power plant • heavy fuel oil power plant • fuel gas compressor • printing house • iron and steel industry • research laboratories • maintenance in temperature of fuel tank located outside • drilling platform • refinery • heating of hazardous premises • 7www.cetal.com
inDusTrial MarKeT secTors
Circulation heater 500 kW, ATEX Fuel oil heatingFlange : 24’’
Re-fining 500 kW, 650°C.Fuel oil preheatingFlange : DN350
Natural gas over heaterDrilling platform100 kW Flange : 12’’
Out-freezing device on exhaust stack, ATEX classified site 1 kW.
Air duct heater 800 kW750°C air heatingAgri-food industry
Industrial oven 3 zones ATEX, 1,5 kW.Hydrocarbons cracking
Demercurization process on gas producing site, 45 kWHeating gases
Nitrogen vaporization and regeneration on steelplant, 610 kWFlange : DN450
agri-fooD inDusTrY equipMenT
energY proDucTion equipeMenT
- Diesel turbines- Steam overheating- Liquid and gaseaous hydrocarbons heating
- Conventional- Nuclear
life sciences inDusTrY
- Pharmaceutical- Biomedical
Use of bolt heaters Equipement for turbinesPower plant
Flange immersion heater 1875 kWHeating nitrogenFlange : 88’’
peTrocHeMicals anD gas inDusTrY
- On-/off-shore extraction- Cracking- Refinery treatment processes
- Chemical industry- Petroleum products shipping
THerMal proDucTion anD processing
poWer planTs
aerospaTialeengineering
plasTic inDusTrY anD pacKaging
oTHer inDusTrial secTors
- Glass- Textile
- Ceramics- Paper
agro-alimentaire • centrale de production d’énergie électrique • centrale nucléaire • centrale thermique au fuel lourd • compresseur de gaz naturel • imprimerie • industrie sidérurgique • laboratoires de recherche • maintien en températures de cuves de fuel situées à l’extérieur • plate-forme de forage • raffinerie• food industries • hydraulic power plant • nuclear power plant • heavy fuel oil power plant • fuel gas compressor • printing house • iron and steel industry • research laboratories • maintenance in temperature of fuel tank located outside • drilling platform • refinery • heating of hazardous premises •8
uniT eleMenTs anD asseMblies sheath :
Protects the heating element from the outside. The type of sheath depends upon the ambient surroundings and temperature of use. (see p.9). It prevents from impact and corrosion. It is formed for the requirements of the application and its fitted with fastening accessories.
The diameter and length depend on the power and load required (W/cm²).
connecting terminals :Depend upon the intensity and are used to connect the heating element electrically.
output insulation :Made of steatite or corubdum to provide dielectric insulation (creepage distance, distance in the air).
sealing material :Keeps out external moisture. its type (silicon, resin, cement) depends upon the industrial application, the external surroundings and temperature (max. temp. for resin 150°C - max. temp. for silicone : 250°C).
output rods :Make up the nonn heating part. Their section depends on the sheath diameter and the inten-sity. The length depends upon the use. (See table below)resistance wire :
Nickel chromium alloy, 80/20, forming the active part of the heating elements.
insulation :Electrically fused magnsesium oxide for effective dielectric insulation and thermal conduction.
Total length : heating and non heating length.
ToTal lengTH
For any designing jobs, we will require the specifications or the conditions of use of the
equipment so as to offer products which are perfectly suitable for the requirements.
iMporTanT
Appropriate surface treatment is applied to adapt the heating elements to different requie-rements :• Mechanical treatment : sand blasting, alumi-
nium or zinc plating, lead or Halar coating
• Chemical treatment : pickling, copper and stainless steel passivating
• Galvanic treatment : tin or nickel plating, electrolytic polishing.
surface TreaTMenT
Connectors, plugs and flanges are crimped, brazed or welded.
They are used to set the heating element as required by the application.
All the elements are made up of an heating part and two non heating parts at either end.
The table below shows the length of the steel or stainless steel output rods which forms the non heating part.
non HeaTing lengTH
Sheath Øoutlet Ø in mmmaterial
6,52
steel
8,53,5
steel
10M4 x 0,7
steel S.steel
13,5M5 x 0,8
steel
16M6 x 1
steel S.steel
16M8 x 1,25
steel
Length in mm 35 •40 •45 • •55 • • • •75 • • • •80 • • • •95 • • • •122 • • • • • •150 • • • • • • • •180 •205 •225 • • • • • • •235 •260 •330 • • • • • • •365 • • •445 • • • •530 • • • • •640 • •800 • • •1000 •1350 •
and
general inforMaTions
S.steel = Stainless steel
asseMblY parTs
agro-alimentaire • centrale de production d’énergie électrique • centrale nucléaire • centrale thermique au fuel lourd • compresseur de gaz naturel • imprimerie • industrie sidérurgique • laboratoires de recherche • maintien en températures de cuves de fuel situées à l’extérieur • plate-forme de forage • raffineriewww.cetal.com 10• food industries • hydraulic power plant • nuclear power plant • heavy fuel oil power plant • fuel gas compressor • printing house • iron and steel industry • research laboratories • maintenance in temperature of fuel tank located outside • drilling platform • refinery • heating of hazardous premises •www.cetal.com 9
elecTrical cHaracTerisTics
Usual diameters 6,5 8,5 10 13,5 16
Maximum use voltage 415 V 415 V 500 V 750 V 750 V
Max. current intensity per resistor 10 A 14 A 14 A 20 A 60 A
Power tolerance >100 W +5 - 10 % +5 - 10 % +5 - 10 % +5 - 10 % +5 - 10 %
Power tolerance <100 W ±10 % ±10 % ±10 % ±10 % ±10 %
DiMensional cHaracTerisTics
The heating length of an element is determined to ensure even distribution of heat in the hea-ted medium.It is calculated to the HL fomula in cm :
Lch en cm = P p.s.
P = heating element nominal powerp = specific load in W/cm²s = periphery of heating element in cm
Mecanical cHaracTerisTics
Sheaths Very high quality rolled, welded or seamless tube manufactured and inspected according to standards ASTM-DIN ou NFA 49-147
Forming The heating elements are available in a variety of shapes adapted to the use circumstances defined in the specifications or by the customer
Tolerances diameter : 6,5 ± 0,1 mm 13,5 ± 0,1 mm8,5 ± 0,1 mm 16 ± 0,1 mm10 ± 0,1 mm
length : ± 1 % with + 5 mm minimumstandard material :
the dimensions in the table are maximaldimensions intented to prevent assembly problems
MATERIALS
Copper Austenitic steel Nickel alloy
CETAL code K V C N Z A I
AFNOR code COPPER Z 6 CNT 18-10 Z 6 CNDT 17-12 Z 15 CN 24-13 Z 8 NC 32-20 Z 3 NC DU 42-22 Z 8 NC 75-15
AISI code 321 316 Ti 309 INCOLOY 800 INCOLOY 825 INCONEL 600
DIN code 1.4541 1.4404 1.4828 1.4876 2.4858 2.4816
Usuels diameters
6,5 • • • •8,5 • • • • • •10 • • • • •13,5 • (1) •16 • • (1) • • • • • (1)
limit temp of use
250° C in the air 750° C 750° C 1000° C 950° C 950° C 950° C
GRADE SELECTION The most important criteria are the temperature of use, the nature of the medium and the surface flux.
St.St. 1.4541
Variety of AISI 304 stabilised with titanium to avoid chromium corbide. It is specially recom-mended for long use in the critical temperature range.
St.St. 1.4404
The addition of molybdenum (2-3%) makes it particularly resistant to chemical agents with a reducing effect. The low carbon content (or addition of titanium) gives it high resistance to intercrystalline corrosion.
St.St. 1.4828
Austenitic steel with a high chromium
St.St. 1.4876
Based on the ternary nickel/iron/chromium sys-tem and characterised by high resistance to cor-rosion in aqueous surrounding. Its high nickel content gives it effective resistance to crevice corrosion under stress due to chlorine ions. Ils high chromium content makes it resistant to oxidation and carburation at high temperatures.
St.St. 2.4858
The addition of molybdenum and cooper make highly resistance to reducing and oxidising acids, crevice corrosion under stress and pitting
corrosion. It is particularly resistant to sulphuric and phosphoric acid.
St.St. 2.4816
Nickel chromium alloy offering high resistance to oxidation at high temperatures and resistance to crevice corrosion under stress due to chlorine ions, corrosion by very pure water and caustic corrosion.
As deposit attacks, corrosion under stress and chemical corrosion (pitting) depend upon the conditions of utilisation, Cetal shall not be res-ponsible for failures and defects due to corro-sion. We encourage you to check if the offered material is suitable for your application.
MecHanical cHaracTerisTics
(1) Stainless steel tube on stock
Non standard products code EXAMPLE : R 16 V1500/0150 (.......)
R = heating resistor 1500 = heating element total length in mm
16 = element diameter in mm 0150 = non heating length in mm on either side of the heating part.
V = sheath grade (Z6 CNT 18-10) (.......) = replying reference
TecHnical inforMaTions
coDificaTion
agro-alimentaire • centrale de production d’énergie électrique • centrale nucléaire • centrale thermique au fuel lourd • compresseur de gaz naturel • imprimerie • industrie sidérurgique • laboratoires de recherche • maintien en températures de cuves de fuel situées à l’extérieur • plate-forme de forage • raffinerie• food industries • hydraulic power plant • nuclear power plant • heavy fuel oil power plant • fuel gas compressor • printing house • iron and steel industry • research laboratories • maintenance in temperature of fuel tank located outside • drilling platform • refinery • heating of hazardous premises •10
TYpe b 100 • THreaDeD sTeel or sTainless sTeel roD
Code no Dimensions Sheats ØØ mm C I 6,5 8,5 10 13,5 16
B104 M4 x 0,7 20 5 •B114 M4 x 0,7 20 5 • •B114 CN M4 x 0,7 20 5 • •B115 M5 x 0,8 30 10 •B115 CN M5 x 0,8 30 10 •B116 M6 x 1 35 10 •B116 CN M6 x 1 35 10 •B118 M8 x 1,25 35 10 •B118 CN M8 x 1,25 35 10 •
TYpe b 200 • plain roD
Code no Dimensions Sheats ØØ mm C I 6,5 8,5 10 13,5 16
B212 2 20 5 •B215 3,5 25 5 • •
TYpe b 300 • braiD or cable
pvc insolaTeD copper cable H07vK 70 °c
Code noDimensions Sheats Øsection mm² C 6,5 8,5 10 13,5 16
B 345 1,5 (1) • • •B 346 2,5 (1) • • • •
silicone insolaTeD copper 180 °c
Code noDimensions Sheats Øsection mm² C 6,5 8,5 10 13,5 16
B 351 / B 361 1,5 (1) • • •B 352 / B 362 2,5 (1) • • • • •B 353 / B 363 4 (1) • • • •B 354 / B 364 6 (1) • •
nicKel braiDeD nicKel 350 °c / 450 °c
B 340 / B 325 1 (1) • • •B 341 / B 326 2,5 (1) • • •B 342 / B 327 2,5 (1) • • •
B 328 4 (1) • • •B 329 6 (1) • • •
B 331 1,5 (1) • • •B 332 2,5 (1) • • •B 333 4 (1) • • •B 335 1,5 (1) • •B 336 2,5 (1) • •B 337 4 (1) • •B 338 6 (1) • •B 339 10 (1) •
rubber insolaTeD copper H07rnf 85 °c
B 325 1 (1) • • •B 321 1,5 (1) • • • • •B 322 2,5 (1) • • • • •B 323 4 (1) • • • •B 324 6 (1) • •
glass braiDeD copper 280 °c
insolaTeD nicKel Wire 700 °c
B 371 1,5 (1) • • • • •B 372 2,5 (1) • • • • •B 373 4 (1) • • • •B 374 6 (1) • •
ceraMic nicKel Wire
B 312 1,5 (1) • • •B 313 2,5 (1) • •
TYpe b 400 • 6,35 Tab
Code no
Dimensions sheath Ødescription C I 6,5 8,5 10
B 411 straight single 25 5 • • •B 412 curved single 23 5 • • •B 413 transverse single 15 5 • • •B 422 straight twin 22 5 • • •B 423 delta twin 22 5 • • •
(1) cable length on request
Code no Dimensions sheath ØC I 6,5 8,5 10 13,5 16
B 521 E 25 5 • • •B 521 • • •B 522 30 10 • •B 523 30 10 • •
Code no Dimensions sheath ØC I 6,5 8,5 10
B 714 15 5 • •
Code no Dimensions sheath ØØ mm C I 6,5 8,5 10
Threaded brass terminal : B 614-6 M6 x 1 30 5 • •Threaded stainless steel terminal : B 623-6 M6 x 1 21 5 • •
Code no Dimensions sheath ØØ mm C I 6,5 8,5 10 13,5 16
B 808 M 6 37 13 •B 810 M 6 37 13 •B 816 M 8 55 15 •
Use in humid conditions
watertighttemperature from - 60°C to + 200°Cdefrosting resistance
Code no Dimensions sheath ØØ mm C I 6,5 8,5 10 13,5 16
B 902-6 6 22 5 •B 914-6 6 22 5 • •
connecTing TerMinals
TYpe b 600 • THreaDeD TerMinal
TYpe b 800 • brazable sTeaTiTe
TYpe b 500 • flaT TerMinal
TYpe b 900 • brass pin TerMinal
TYpe b 700 • screW TYpe brass TerMinal
C
ØI
C
Ø
I
C
Ø
˜ 65C
Ø
˜ 65
C
Ø
˜ 65C
Ø
˜ 65
C
Ø
I
C CI I
IIC C
C
ØI
C
Ø
I
CI
CI
CI
Ø
C
ØØ
CII
agro-alimentaire • centrale de production d’énergie électrique • centrale nucléaire • centrale thermique au fuel lourd • compresseur de gaz naturel • imprimerie • industrie sidérurgique • laboratoires de recherche • maintien en températures de cuves de fuel situées à l’extérieur • plate-forme de forage • raffineriewww.cetal.com 10• food industries • hydraulic power plant • nuclear power plant • heavy fuel oil power plant • fuel gas compressor • printing house • iron and steel industry • research laboratories • maintenance in temperature of fuel tank located outside • drilling platform • refinery • heating of hazardous premises •www.cetal.com 11
HeaTing eleMenTs accorDing To specificaTions
Tubular heating elements are required solutions for maintaining the temperature of solids, liquids, gases or heating them up electrically with the help of the Joule effect, conduction, convection or radiation in all types of industry.
Tubular heating elements are produced according to drawings, models, templates or customers specifications, with a 6600 mm (260’’) maximum developed length.
The heating element, diameter ranging from 6.5to 16 mm, is made of copper, stainless steel or incoloy. Watt densities are adapted to processes.Unit production, prototyping and mass-production are feasible.
benDing exaMples
rr
wrong
Non heating radiusNon heating radiusNon heating radius
rr
wrong
Non heating radiusNon heating radiusNon heating radius
rr
wrong
Non heating radiusNon heating radiusNon heating radius
Usual sheath Ø 6,5 8,5 10 13,5/16Copper 8,5 9 12 22,5Stainless steel 7,5 9 11 20Incoloy 11 17,5 18,5 30Inconel 20 40
r = minimum bending radius
TYpe 300 connecTors
Code no
Material Dimensions Sheatd E e L Ø
310 CN S.steel M10 x 1 R14 3 15 6,5310 Brass M10 x 1 R14 3 15 6,5310 LTS Brass M10 x 1 R15 3 12 6,5312 LTS Brass M12 x 1 R17 4 12 8,5312 S.steel M12 x 1 R18 4 12 6,5-8,5312 Brass M12 x 1 R18 4 12 6,5-8,5312 Fe Steel M12 x 1 R18 4 12 6,5-8,5313 Brass G 1/4’’ H19 4 14 8,5314 Brass M14 x 1,5 R20 4 14 8,5-10314 L Brass M14 x 1,5 R20 4 20 8,5-10314 Fe Steel M14 x 1,5 R20 4 14 8,5-10314 FeL Steel M14 x 1,5 R20 4 20 8,5-10314 CN S.steel M14 x 1,5 R20 4 16 8,5-10316 Brass M16 x 1,5 R22 4 17 8,5-10316 Fe Steel M16 x 1,5 R23 6 45 10320 Brass M20 x 1,5 R27 5 20 13,5320 Fe Steel M20 x 1,5 R27 5 20 13,5320 CN S.steel M20 x 1,5 R27 5 20 13,5324 Brass M24 x 1,5 R32 5 20 16324 Fe Steel M24 x 1,5 R32 5 20 16324 CN S.steel M24 x 1,5 R32 5 22 16
asseMblY parTs
flange To specificaTions
carbon steel or stainless steel, cut or deep-drawn1 - 5mm thick.
To screW To fix
Heating elements with such connectors are supplied with nuts and seals.
MiniMuM benDing raDius
The heating part cannot in any circumstance start in the bending radius. Its starting point must always be located at least 15 mn before or after the bend.
The minimum bending diameter depens upon the grade. See next table.
Examples :
E
Le
d
• food industries • hydraulic power plant • nuclear power plant • heavy fuel oil power plant • fuel gas compressor • printing house • iron and steel industry • research laboratories • maintenance in temperature of fuel tank located outside • drilling platform • refinery • heating of hazardous premises •12
coDe no 11-1-00-00 a coDe no 11-1-00-11 a
rr
NON
rr
NON
coDe no 13-2-00-00 a
rr
NON
coDe no 13-2-00-00 b
rr
NON
coDe no 12-1-11-00 a coDe no 13-1-00-00 a coDe no 13-1-20-00 a coDe no 15-1-22-00 a
rr
NON
rr
NON
rr
NON
rr
NON
coDe no 31-1-00-11 a coDe no 31-1-11-00 a coDe no 56-1-10-11 a coDe no 56-1-10-00 a
rr
NON
rr
NON
rr
NON
rr
NON
coDe no 44-4-00-00 a coDe no 43-3-11-11 a coDe no 46-6-01-11 a coDe no 45-5-01-11 b
rr
NON
rr
NON
rr
NON
rr
NON
benDing exaMples
realizaTion exaMples
• food industries • hydraulic power plant • nuclear power plant • heavy fuel oil power plant • fuel gas compressor • printing house • iron and steel industry • research laboratories • maintenance in temperature of fuel tank located outside • drilling platform • refinery • heating of hazardous premises •www.cetal.com 13
eleMenTs forMeD To TeMplaTes
These elements offer a very good alternative for duppilcate-moulded heating plates, particulary for heating hot-channel distributor units in the plastics industry. Because of the specific manufacturing conditions used by Cetal, the temperature is distributed very evenly over the entire formed heating element.
TecHnical caracTerisTics
Power : according to specificationsAlimentation : mono 230 V - 400 V or elseTolerance of bending : individuel controle on sizeMinimum bending radius see table p11Sheath Ø 6,5 : ± 0,1Sheath Ø 8,5 : ± 0,1Sheath Ø 10 : ± 0,1Data sheet : see www.cetal.com
The heating elements are embedded in aluminium, brass, copper-nickel or cast iron. These sturdy and tightly sealed products are designed for use in severe industrial surroundings (impacts, vibrations) to provide even heating, flat or cylindrical.
Aluminium-moulded elements, used for heating applications up to 400 °C, can have a maximum mass of 400 kg. Brass-moulded elements (maximum process temperature : 600°C) and Cupronickel-moulded elements (maximum process temperature : 650°C) can have a maximum mass of 300 kg.Duplicate-moulded elements (collars, plates,…) are manufactured on request. Devices can be produced according to ATEX directives.Gravity moulding is performed either in a sand mould or in a metal mould depending upon the number of pieces and the mechanical characteristics required.
Duplicate-moulded elements may be fitted with sheaths for the following functions :• cooling by means of circulating
water or cooling fluid.• heating of compressed air or
pressurised gas etc.The elements come in the form of half bands and offer an excellent
alternative for heating sheaths or reactors. They are in accordance with CENELEC standard and ATEX directive. They have an EC type examination (ATEX 6094X) delivered by the LCIE.
Infrared radiation is especially suitable for heating moving parts in applications such as paint curing, print drying or sterilisation. The armoured elements are heated to a surface temperature of 750 - 900°C and emit in the spectrum of medium wavelengths ranging from 2.82 µm to 247 µm.
These straight or hairpin-shaped elements can be mounted in front of a reflector with high reflective power.
These sturdy generators are used in all positions and surroundings : hot, humid or dusty.
DuplicaTe-MoulDeD/casTeD eleMenTs
infrareD generaTors
recoMMenDeD TeMperaTures for use
Alu : 400 ° CBrass : 600 ° CBronze : 650 ° CCupronickel : 750 ° CCast iron : 950 ° C
TecHnical cHaracTerisTics
Power supply : single or 3 Ph, 230 V - 400 V or other voltageMaximum load on the element : 20 W/cm²Maximum weigth : alu 400 kg / brass 300 kgProtective casing : sealed or explosion-proofElectrical connection via threaded terminals or cables welded to the heating elements outputsMachined : to specificztionsFastened : via boltsHeat-insulation : upon request, depending on the temperatureData sheet form : see www.cetal.com
Wavelength
Blinded element to
Wavelength
Blinded element to
Quartz sheath
Strand
Ceramic ware
• food industries • hydraulic power plant • nuclear power plant • heavy fuel oil power plant • fuel gas compressor • printing house • iron and steel industry • research laboratories • maintenance in temperature of fuel tank located outside • drilling platform • refinery • heating of hazardous premises •14
CETAL has extensive experience in these screw plug immersion heaters, which are commonly used for heating static or circulating water, rinsing baths, special oils, acids, heat transfer media, heavy fuel oil or gas.
Screw-on immersion heaters are made of three or six copper, stainless
steels or incolloy heating elements, depending on the heated fluid, brazed or welded on assembly plugs, with metric or British thread sizes.
They are used for heating static or circulating water, oils or other specific liquids, air or gasses, at a maximum operational pressure of
15 bars. Power ranges from 100 W to 35 kW, for 230 V – 380 V – 690 V or other specified voltages. Watt densities are adapted to the customers’ requirements. ATEX certified products are available for explosive atmospheres.
principle DraWing
TYpe 400 rounD plug
Code no Material Dimensionsd E e L
419 Brass M19 x 1,5 R22 2 10437 Brass M37 x 1,5 R45 5 11445 Brass M45 x 2 R55 5 10477 Brass M77 x 2 R90 4 10
Use movable immersion heaters mounted on handle or cover
asseMblY parTsTYpe 500 Hex plug
Code no Material Dimensionsd E e L
545 FC Brass M45 x 2 H60 8 31577 FC Brass M77 x 2 H90 10 31577 FC CN S. steel M77 x 2 H90 10 31545 Brass M45 x 2 H60 10 15527 Brass G 3/4’’ H32 8 15534 Brass G1’’ H32 8 15577 Brass M77 x 2 H95 10 20577 CN S. steel M77 x 2 H95 10 20
Use bottom immersion heaters with OR* type enclosure
Code no Material Dimensionsd E e L
621 Brass G 1/2’’ H30 6 15627 Brass G 3/4’’ H45 8 15634 Brass G1’’ H45 8 15642 Brass G 1 1/4’’ H60 8 15649 Brass G 1 1/2’’ H60 10 15649 CN S. steel G 1 1/2’’ H60 8 15659 Brass G 2’’ H70 8 15676 Brass G 2 1/2’’ H95 10 20676 CN S. steel G 2 1/2’’ H95 10 20
IL
Ø
ILCONNECTION BOX
SHEATH SPACERCONNECTION
HLCL
SLEEVE
Ø
SCREW NIPPEL
TYpe 600 Hex plug
Code no Material Dimensionsd E e L
645 Fe Steel M 45 x 2 H60 8 15645 CN S. steel M 45 x 2 H60 8 15645 Brass M 45 x 2 H60 10 15677 Fe Steel M 77 x 2 H95 10 20677 CN S. steel M 77 x 2 H95 10 20677 Brass M 77 x 2 H95 10 20
Use
immersion heaters with pivoting protective cover and • either on and gland • either or side gland
screW on iMMersion HeaTers
removable heating rodsHeating elements brazed or welded
Stand off terminal enclosure for temperature > 120°CStand on terminal enclosure Stand on terminal enclosure Stand off terminal enclosure for temperature > 120°C
HL = heating lengthCL = cold lengthIL = immersion lengthSOL = stand off length
Code no Material Dimensionsmm
Brass 110 x 110 x 15Steel 105 x 105 x 25S. steel 105 x 105 x 25
square flange
non HeaTing lengTH selecTion/MounTing recoMManDaTion
Special plugs or flanges on request
Pour température > 120° C
HICLSOL
Ø
IL
HLSOL CL
Pour température > 120° C
Ø19
Ø
IL
Ø19
HLCL
Ø
IL
MInIMaL LEvEL MInIMaL LEvEL Must bE vEnt bEFORE EnERGIZED
OutLEt
InLEt
Cold length
• food industries • hydraulic power plant • nuclear power plant • heavy fuel oil power plant • fuel gas compressor • printing house • iron and steel industry • research laboratories • maintenance in temperature of fuel tank located outside • drilling platform • refinery • heating of hazardous premises • 15www.cetal.com
Movable iMMersion HeaTers
WelDing ring nuT / sealThread DimensionsD1 D2 h Steel S. steel
M45 x 2 55 70 18 • •M77 x 2 90 110 18 • •G1’’ 40 45 12 •G1’’ 1/4 55 60 12 •G1’’ 1/2 60 70 18 •G2’’’ 68 75 18 •G2’’ 1/2 90 110 18 •
Thread Nut Sealh a Steel S. steel Brass Low S. steel
M37 x 1,5 6 45 • • •M45 x 2 8 60 • • • •M77 x 2 10 90 • • • •G1/4’’ 5 19 • •G3/4’’ 6 32 • •G1’’ 6 45 • •G1’’ 1/4 8 60 • •G1’’ 1/2 8 60 • •G2’’ 10 70 • •G2’’ 1/2 10 90 • • •
orpM / orgM Code no Material Base Ø AxA H Gland
ORPM Alu. 45-1’’1/2-2’’ 87x87 93 13ORGM Alu. 77-2’’1/2 105x105 111 16Sealed protected cover to standard NFC 20-010.Standard version IP 55Special version IP 66
Optiongland on coverexternally or internally controlled thermostat
ors / orT Code no Material Base Ø AxA H Gland
ORS 45 Protected metal 45-1’’1/2-2’’ 165x120 65 13 ou 16
ORS 77 Protected metal 77-2’’1/2 165x120 65 16 ou 21
ORT 45 ABS plastic 45-1’’1/2-2’’ 180x106 90 13 ou 16ORT 77 ABS plastic 77-2’’1/2-2 180x106 90 16 ou 21
Optional
thermostat (16A 230/400 V)limiter (10A 230/400 V) terminal plate, lamp, contactorS. steel version
Regulating (thermostat) or safety (limiter) devi-ces intended for use in the various terminal enclosures (ORS, sealed and explosion-proof). They come in single and three-phase models with breaking power equal to 5 - 16 A.
For higher power ratings, a control contactor must be fitted in the electrical cabinet. Several vapour tension models are available to cover major industrial applications in normal and tropicalised versions.
Pivoting aluminium enclosure with side gland for screw type or flanged immersion heaters.
Pivoting enclosure for screw type, remova-ble or flanged immersion heaters.
MounTing accessories
sTanDarD TerMinal enclosure
TeMperaTure conTrol
Stainless steel tube Ø 36 x 42
Heating elements
L
Terminal enclosure ORS
All standard height : 1000 other on request.
These heaters are designed for heating liquids in open tanks with a low or very variable level such as those used for degreasing baths and surface treatment. They are adapted to process requirements and the dimensional restrictions of equipement and can be used for vertical or horizontal (bottom) heating.
specificaTions
Power and voltage to specificationVoltage up to 750 V, single or three-phase connectionWatt density of requestHeating elements welded to the fastening flange or to a sealed casing welded to the stainless steel rising sheathCasing away from the evaporation areaDimensions adapted to process equipment Retaining spacer on the arrayTemperature control facilityData sheet form : see www.cetal.com
agro-alimentaire • centrale de production d’énergie électrique • centrale nucléaire • centrale thermique au fuel lourd • compresseur de gaz naturel • imprimerie • industrie sidérurgique • laboratoires de recherche • maintien en températures de cuves de fuel situées à l’extérieur • plate-forme de forage • raffinerie• food industries • hydraulic power plant • nuclear power plant • heavy fuel oil power plant • fuel gas compressor • printing house • iron and steel industry • research laboratories • maintenance in temperature of fuel tank located outside • drilling platform • refinery • heating of hazardous premises •16
These heaters are particularly suitable for heating and maintaining the temperature of large volumes or heating circulating fluids such as water, heavy fuel oil, thermal fluid, air or gas. They can be fitted on tanks, citerns, boilers and circulation reheaters and are the best electrical heating system for a range of industries such as food processing, chemicals, textiles, plastics etc.
The stainless steel or incolloy heating elements are generally hairpin-bended and are welded to the DIN/
ASA standardized flanges according to procedures which have CODAP, TÜV and ASME approval.
The watt density, ranging from 0.1 to 15 W/cm², is determined from the working parameters of the process and the exchange coefficients. For a maximum immersion length of 3300 mm, the power delivered by a flange immersion heater can reach several MW.
The electrical cabling in one or more paces gives access to several power
steps. Connection blocks and rods are used to ensure the electrical connection.
The array may be fitted with a temperature control system whereby the power and specific load are controlled by parameters such as flow rate, pressure, viscosity, temperature etc.
The bundle consists of heating elements, the active part is the 80/20 nickel chrome wire. Perfectly centered in the armoured sheath, the latter is supported by high density electrical insulation. The heating element is brazed or welded onto the mounting flange.
The bundle consist of heating cartridges or cylinder resisitances placed in thimble tubes, which means they can be changed without emptying the fluid. The thimble tubes are brazed or welded onto the mounting flange.
principle DraWing
MounTing recoMMenDaTion (level/floW conTrol) - precauTions of use
version with removable heating rodsversion with welded heating elements
Stand off enclosure for temperature > 120° C
Stand on enclosure Stand on enclosure
flange iMMersion HeaTers
cHaracTerisTic of THe bunDleThe heating elements maximum number depends on the diameter of the flange (item 3), on the welding procedure (item 4); it determines the minimum dimensions of the enclosure.
version WiTH sTanD off enclosure WiTH gap
Flange DIN(DN)INCH
803
1004
1255
1506
2008
25010
30012
40016
50020
Ø maximum heating elements
8,5 - 10 6 9 15 21 39 54 84 147 21013,5 3 6 9 12 21 27 39 72 11116 3 3 6 9 15 24 30 60 8719 3 6 9 15 30 * * * *
Boîtier Bride
ÉLément chauffant
version WiTH sTanD off enclosure WiTHouT gap
Flange DIN(DN)INCH
803
1004
1255
1506
2008
25010
30012
40016
50020
Ø maximum heating elements8,5 - 10 3 6 9 15 27 39 57 99 15313,5 3 3 6 9 18 24 39 66 9616 3 3 6 6 12 18 27 48 7819 3 6 9 12 24 * * * *
version WiTH sTanD on enclosure
Flange DIN(DN)INCH
803
1004
1255
1506
2008
25010
30012
40016
50020
Ø maximum heating elements
8,5 - 10 6 9 15 24 42 63 93 165 255
13,5 3 6 9 12 24 39 60 102 156
16 3 3 6 9 15 27 42 78 123
19 3 6 12 21 36 * * * *
HL = heating lengthCL = cold lengthIL = immersion lengthSOL = stand of length
(never thermal insulated)
Stand off enclosure for temperature > 120° C
CL HL
ILSOL
Ø
CL HL
IL
Ø
CL HL
ILSOL
ØCL HL
IL
Ø
MInIMaL LEvELMInIMaL LEvEL
nOn hEatInGInLEt OutLEt
puRGE bEFORE staRtInG
MInIMaL LEvEL
nOn hEatInG
nOn hEatInG
enclosure bottom flange
HE
flange
HE
HE
enclosure bottom
enclosure bottom
agro-alimentaire • centrale de production d’énergie électrique • centrale nucléaire • centrale thermique au fuel lourd • compresseur de gaz naturel • imprimerie • industrie sidérurgique • laboratoires de recherche • maintien en températures de cuves de fuel situées à l’extérieur • plate-forme de forage • raffineriewww.cetal.com 10• food industries • hydraulic power plant • nuclear power plant • heavy fuel oil power plant • fuel gas compressor • printing house • iron and steel industry • research laboratories • maintenance in temperature of fuel tank located outside • drilling platform • refinery • heating of hazardous premises •www.cetal.com 17
cHaracTerisTics of THe flangeThe nature of the material and the dimensions of the flange, thickness and cross section, are determined by the operatio and calculation requirements. Standard flanges will be prefered (rep.3).
The nature of the fluid to be heated and the maximum pressure allow the shape (joining) and the surface condition (roughness) of the joint face to be defined.
ø Flange
DNinch
1506
2008
25010
30012
35014
40016
45018
EnclosureA x B mm 240 x 240 245 x 290 285 x 290 340 x 350 370 x 380 420 x 430 480 x 490h mm 400 430 430 480 480 480 480
cHaracTerisTics of THe enclosure
proTecTeD enclosure versionThe robust enclosure (6) protects people as well as the electrical connections and the temperature control equipement. To satisfy all environmental conditions, CETAL offers different type of enclosures made of PVC, aluminium, coasted steel or stainless steel depending on the atmosphere (corrosive, saline, tropical). The protection degree (IP and EX) depends on the conditions of use (industrial atmosphere, dust, explosive atmosphere).
The enclosures dimensions are determined by the number of elements, the number of junction blocks, busbars or teminal plates (7), the number and the size of the cable glands and the cross section (bending radius) of the power supply cables.
When installing, please always ensure that there is sufficient free space around the enclosures to allow the air to circulate around it.
spacersThe exchange conditions (state of laminary or turbulent flow) are modified according to shape and number of spacers (5). The hydraulic
diameter may be reduced by adding one or more tubes in the bundle.
The heating elements are welded according to certified welding procedures (QMOS) in compliance with CODAP, ASME ou TÜV
requirements… or brazed. Penetration testing and pressure tests in a hydraulic chamber guarantee the perfect quality of the welds.
asseMblYs
Contre bride à colerette à souder en boutCiterne / Cuve / Corps de réchaueur à circulation
Joint
Bride TP pleine
Mâle
Joint
Femelle
Mâle
Joint
Femelle
ø FLANGE
DNinch
803
1004
1255
1506
2008
25010
30012
35014
45016
EnclosureØ mm 155 180 210 235 285 340 390 440 490h mm 150 150 200 200 250 250 250 250 250
WaTerproof enclosure version ip67 iK 10
explosion proof enclosure version
forM
Contre bride à colerette à souder en boutCiterne / Cuve / Corps de réchaueur à circulation
Joint
Bride TP pleine
Mâle
Joint
Femelle
Mâle
Joint
Femelle
Flat blind flange Form A Flat blind flange Form B
enclosureWN RF flange WN Ring joint facings flange
Wiring on busbars (7)
de barres Max. voltage 750 VMax. power > 1 MW
Welding (14)according to certifed
procedures
Sheath (1)Ø mm : 6,5 - 8,5 - 10 -
13,5 - 16Material : copper stainless steel AISI 321- 309 - 316 L Incoloy - Inconel 600
Spacer (5)- Spider- 1/2 moon- Baffles- Rods
Rail
Cable entry (10)
Heating elements (2)surface watt densityup to 16 W / cm2
Terminal enclosure (6)- Copper steel or
stainless steel- IP67- EEX
- Tropicalised
Liftingring (9)
Mounting flange (3)AFNOR / DIN / ANSI - Diameter and thickness according to specifications
possible up to DN 700/28”- Materail : steel or stainless steel- Bearing area FS / SEM / DEM / RF
Immersed length
up to 3300 mm
Tube (8)For temperature control devicelimitater thermostatThermocouple
Enclosure “e” Enclosure “d” aluminium or brass
Enclosure “d” steel or stainless Enclosure “de” Enclosure “d”
Type BCAE BRAE ** IIB/BIIC BROAE ** /BRGM BRAE * IIB/IIC BRAE 55Material C.St / St. St C. St alu C. St BrassAtmosphere - 40 + 60° C - 40 + 60° C - 40 + 60° C - 20 + 60° C - 20 + 60° CMode of production EEXeII 2GD EEXdIIB/C 2GD EEXdIIC 2GD EEXdeIIC 2G EEXdIIC 2G
Ability LCIE01 ATEX 008U
LCIE06 ATEX 008U
LCIE04 ATEX 008U
LCIE01 ATEX 006U/007U
LCIE01 ATEX 001U
Size mini 100x100x80 Ø 210 Ø 80 Ø 200 Ø 50Size maxi 1000x2000x500 Ø 960 Ø 130 Ø 770
Contre bride à colerette à souder en boutCiterne / Cuve / Corps de réchaueur à circulation
Joint
Bride TP pleine
Mâle
Joint
Femelle
Mâle
Joint
Femelle
Contre bride à colerette à souder en boutCiterne / Cuve / Corps de réchaueur à circulation
Joint
Bride TP pleine
Mâle
Joint
Femelle
Mâle
Joint
Femelle
Contre bride à colerette à souder en boutCiterne / Cuve / Corps de réchaueur à circulation
Joint
Bride TP pleine
Mâle
Joint
Femelle
Mâle
Joint
Femelle
blind flangeWN counter flange weldet on the tank,
vessel nozzie
Male
Gasket
Female
Male
Gasket
Female
Ø
h
• food industries • hydraulic power plant • nuclear power plant • heavy fuel oil power plant • fuel gas compressor • printing house • iron and steel industry • research laboratories • maintenance in temperature of fuel tank located outside • drilling platform • refinery • heating of hazardous premises •18
Forced circulation fluid heaters are particularly suited to the heating of liquids such as water, superheated water, heavy oil, fuels, oils and ther-mal fluids and to the heating of gases under pressure such as air, steam (superheater), nitrogen, hydrogen, methane, etc.Defined specifically for each indus-trial application, these heaters consist of one or more steel or stain-less steel bodies linked hydraulically in series and/or in parallel and meet the requirements conforming to the PED European Directive.
To prevent corrosion problems rela-ted to the working fluid and operation temperature, the constituting ele-ments of the heating array are built with the appropriate stainless steel. The heating elements and the bundle spacers are designed to obtain the optimal heat exchange coefficient. The heating array, with a maximum immersion length of 3300 mm, can be equipped with temperature control devices to regulate the sheath watt density (W/cm²) as a function of parameters such as fluid flow, pres-sure, viscosity, fluid temperature, sheath skin temperature, etc…
Built in accordance with the construc-tion codes specified for the pressure and temperature in question (CODAP, ASME, TEMA, STOOMWEZEN…), these assemblies allow very high power ratings to be reached (= 2000 kW) and the controlling of circulation speeds, essential characteristics for guaranteeing an excellent thermal exchange.
process circulaTion HeaTers
Air circulation heater 400° C 300 kW 6 x 50 kW serial Air Super heater at 1000° C with VHP heating rods
The temperature measuring devices that equips our electrothermal assemblies are adpated to the method of operation selected in relation to the characteristics of the regulator (thermocouple type J-K etc). Their position (temperature of the tube-of the fluid) are deteminated by the process requirements (regulation-safety).
The regulation method choise (phase angle - wave train) depends on the application. For equipment with very high power rating, the combination of the «all or nothing» (ON/OFF) and analog solutions allows controlling of the electric power supplied over all range available.
The control/regulation cabinets enclosures display the signals and process controlled: operation - faults - temperature - set points.The later can be controlled in local or remote mode, manually or automatically, but as call or nothing or on a Modbus, FIB, Profibus DP network. Built according to the NCF 15. 000-EN 60204-I or NEMA standards, control/regulation and power cabinets or enclosures are adapted to the environmental conditions (indoor ou outdoor installation in humid, tropical, saline zones etc...) and the zone classification.
They may be fitted with ventilation, heating or cooling systems.An operation with a variable surface power density will be controlled by an analog control
signal ( thermocouple, temperature, probe). The power will be controlled by thyristor.
The electric heating of industrial processes using heating elements or assemblies, requires high-per-formance control that is properly adapted to the characteristics of the fluid to be heated (thermosensitive - variable viscosity), to the operational temperature (accuracy - stable or variable) and to the specifications
of the process (stable - slightly or highly variable flow rate/volume).
These characteristics allow the deter-mination of the system of regulation and the equipment selection for the regulation loop in order to guarantee optimum control of the dissipated energy.
poWer conTrol panels
ANALOGICAL SYSTEM
PROTECTION
TRANSFORMATOR
POWER CONTROL
PRESSURESENSOR
HEATING ELEMENTS
HIGH SPEED FUSES
CG
BLOCK THYRISTOR
CONTROLSENSOR
SAFETYSENSOR
REGULATORSWITCH
RELAY
LIGTH
FLOW SENSOR
Power control panel with 2 Thyristor
Control enclosure EExpll 70° C
• food industries • hydraulic power plant • nuclear power plant • heavy fuel oil power plant • fuel gas compressor • printing house • iron and steel industry • research laboratories • maintenance in temperature of fuel tank located outside • drilling platform • refinery • heating of hazardous premises • 19www.cetal.com
Ribbed resistance heaters are ideal for the convection-heating of air in stoves, industrial ovens, drying ca-binets and facilities, air-conditioning equipment etc. Ribbed heaters are generally used to heat air or non corrosive gas by natural or forced convection.The heating elements are made of Z6
CNT 18-10 stainless steel (ST. ST. AISI 321) tubes of diameters 8.5, 10, 13 and 16 mm. The sheaths are fitted without clearance with electrogralva-nized steel ribs.Equipped with crimped steel fittings (M14 or M21), the heating elements are delivered with joints and nuts; B500 type flat connecting terminals
are used to realize the electrical connection.We have the technology for making compact air duct heaters. The hea-ters designed for use in applications requiring high temperatures or in corrosive atmospheres are fitted with stainless steel ribs and connectors.
sTainless sTeel supporTing roD se ar 8 - se ar 10
ø 1
6
ø5
30
caDMiuM proTecTeD sTeel supporTing roD se ar 16
supporTing seTJs ar 16
supporTing seT Js ar 8 - Js ar 10
enclosure WiTH cg n°13 orpMa
enclosure WiTH cg n°16orgMa
accessories
ribbeD HeaTing eleMenTs
TecHnical cHaracTerisTics• AISI 321 stainless steel element with rectangular
ribs made of zinc-palted or stainless steel, snugly fitted on the armouring sheath
• Crimped or welded steel connectors• Supplied with washers and nuts• Elecrical connection via standard B500 series
terminals
• Low heating at the bent part of the ribbed element
• Data sheet form : see www.cetal.com
Optional features : • Enamelled or stainless steel ribbig, round or
rectangular• Specially formed• Special connecting terminals for corrosive,
humid and tropical atmospheres
Recommanded watt density : • 2 W/cm² for 0 m/s convection• 4 W/cm² for min. speed 2m/s• 5 W/cm² for min. speed 3m/s
inDusTrial air DucT HeaTers
The elements are specially shaped so as to obtain the best curtain type exchange surface and are fixed on a stainless steel or steel plate. Fitted with an electrical terminal enclosure separate from the plate for uses at temperatures over 120 °C, the batte-ries may be powered by three-phase supplies up to 750 V.
The heating elements are wired with high temperature cables, generally in busbars mounted on insulators at one or more rates.
Designed to be used at temperatu-res up to 850 °C, the plates may be
mounted on steel or stainless casings to allow their installation on the duct network.The air duct heater may be fitted with temperature control systems (thermostat, limiter, thermocouple) whereby the power may be control-led according to parameters such as flow rate, outlet temperature, surface watt density (W/cm²). The equipment may be mounted on the outlet of the circulating fluid stream or fixed onto the heating elements (surface tempe-rature control).
Heating of air containing tack in suspension Power rating 540 kW inlet/outlet temperature 190/400° C
• food industries • hydraulic power plant • nuclear power plant • heavy fuel oil power plant • fuel gas compressor • printing house • iron and steel industry • research laboratories • maintenance in temperature of fuel tank located outside • drilling platform • refinery • heating of hazardous premises •20
equipMenTs for HazarDous aTMospHeres
Used in hazardous atmospheres for heating gas or liquids subject to natural convection or forced circulation, CETAL immersion heaters have certificates issued by the LCIE. They meet the requirements of the new European Directive 94/9/EC of 23.03.94 (ATEX) and standards (CENELEC). The different versions
– immersion heaters with casings with a component certificate, immersion heaters with a certificate of conformity – the wide choice of possibilities and methods of protection, guarantee a solution suited to the customer’s requirements.
sTanDarD inforMaTion - aTex DirecTives
gas groupsThe hazard of a mixture air and other substance is depending of his flammable concentration and of his own characteristics. Two classifications according the hazard :
Place of use Group : CENELEC / IEC Group / class / zone Canada and USA Representative gases
Mines susceptible to friedamp I Gaseous mines Methane
Surface industries
II A D-CI I Div 1/2 II A-CI Zone 0/1/2 Propane, butane, benzene, acetone, alcool, methyl, kerosene, mazout, petroleum naphta
II B C-CI I Div 1/2 II B-CI Zone 0/1/2 Ethylene, ethyl, ether, butadiene
II C B-CI I Div 1/2A-CI I Div 1/2 II C-CI Zone 0/1/2 Hydrogen
Acetylene
MarKing TeMperaTuresThe flammable procucts have different ignition temperatures. The more the temperature is low, the more the product is dangerous.
The equipments intended to be in operation in an hazardous area are classified according the maximal surface temperature. NB : for electrical equipment with explosion proof enclosures the gases and vapours are classified according to the maximum experimental safety
clearance (IEMS) in subdivision A-B-C. The NEC 500 standard escablishes a classification in groups.
T°C 450 300 280 260 230 215 200 180 165 160 135 120 100 85
CENELEC T1 T2 T3 T4 T5 T6NEC T1 T2 T2A T2B T2C T2D T3A T3B T3C T3D T4 T4A T5 T6
elecTrical eleMenTs proTecTion in HazarDous aTMospHere
The EN 60079-0 standard (general rules) spe-cifies the general rules for the construction, testing and marking of electrical equipment, cable entries, components for use in explosive
atmospheres in the form of gases, vapours or mists. Different methods of protection accor-ding to particular concepts may be used for the manufacturing of electrical equipment. There
are described in the standards (EN 60079-X) which complete or modify the EN 60079-0 standard.
In combustible dust atmosphere, the protection can be secured against dust by tightening and surface temperature limiting.
iec/cenelec anD nec sTanDarDs
NB : The NEMA 250 takes into consideration the environment conditions (cold, vapour, corrosion) and the risk in relation to mechanical shocks. Although it is possible to convert from NEMA to IP, the opposite is not possible or the tests and trials are different.
National Electrical Manufacturers Association (US)
Enclosures are often required to be sealed. The index indicates the degree of protection against solid bodies (1 st fig. from 0 to 6) and against liquids (2nd fig. from 0 to 8). For protection against electric shocks the NFC 20030 (IEC 60529) defines four classes. The EN60079-0
standard requires, for all equipment, at least one connecting element for the protective conductor or equipotential bonding.
NOTE : NEMA standards 7 to 10 concern equip-ment for hazardous areas.
enclosure proTecTion inDices
Correlation between 250 STANDARD AND IP (IEC)
NEMA 1 IP 10 NEMA 3-3S-13 IP 54
NEMA 2 IP 11 NEMA 4-4X IP 56
NEMA 3R IP 14 NEMA 6-6P IP 67
NEMA 5-12-12K IP 52
THe european DirecTives
Its objective is to improve protection in terms of the health and safety of workers exposed to the risk of explosive atmospheres. It stipulates technical and organisational protective measures to be taken and the documents relating to protection. The risk of explosion must be prevented and dangerous locations must be classified into zones.
Classification of hazardous location where there is a risk of explosion : it is defined that the zoning responsability lies on the shoulder of the end-user. This means he must update the zoning of its premises every time a change affecting the zoning occurs e.g. : changing its progress, changing the organisation, of its units, revamping them or putting in operation assemblies that due to their intended use bring their own zoning.
This, of course includes the new assemblies in relation to the conditions that may affect them e.g. : existing zoning, temperature condition.
DirecTive 1999/92/ce enD (user DirecTive)
Probability of an ATEX High Average and low Very low Improbable
DURATION OF PRESENCE >1000 hour/year 10 < hours/year < 1000 1 < hours/year < 10 1 < hours/year
DEFINITIONS Location where an explosive atmosphere is present all the time or for long periods or irregulary
Location where an explo-sive atmosphere is likely to occur occasionally under normal operating conditions
Location where an explosive atmosphere is not likely to occur under normal operating conditions or, if it is present nevertheless, is only of short duration (foreseeable abnormal operating conditions)
No hazardous location
Explosive atmosphere Continuous presence Intermittent presence (normal operation conditions)
Occasional presence (abnormal operation conditions)
IEC, Europe, France Zone 0 (gas)Zone 20 (dust)
Zone 1 (gas)Zone 21 (dust)
Zone 2 (gas)Zone 22 (dust)
Canada, (CEC) 1USA (NEC) 2
CI II Div 1 / CI I Zone 0 (gas)CI II Div 1 (dust)CI II Div 1 (fibres)
CI II Div 1 / CI I Zone 1 (gas)CI II Div 1 (dust)CI II Div 1 (fibres)
CI II Div 2 / CI I Zone 2 (gas)CI II Div 2 (dust)CI II Div 2 (fibres)
(1) CEC : Canadien Electricity Code (2) National Electricity Code
• food industries • hydraulic power plant • nuclear power plant • heavy fuel oil power plant • fuel gas compressor • printing house • iron and steel industry • research laboratories • maintenance in temperature of fuel tank located outside • drilling platform • refinery • heating of hazardous premises •www.cetal.com 21
DirecTing 94/9/ce (ManufacTurer DirecTives)It states the equipment class according to protection degree. Must be applied to equipments and systems.
The directing specifies the conformity valuation procedures.
Asparatus categories Inflammable substances Protection level Fault protection Comparison with current practice
and IECCETAL products
ASPARATUS GROUP 1 (mines)
M1 Methandust Very high level 2 type of protection or
2 independant faults GROUP I NO
M2 MethanDust High level 1 type of protection normal operation GROUP I NO
ASPARATUS GROUP 2 (surface)
1Gas, vapourMistsDust
Very high level 2 type of protection or 2 independant faults GROUP II Z0 (gas) / Z20 (dust) NO
2Gas, vapourMistsDust
High level 1 type of protection usual & frequent disturbance GROUP II ZI (gas) / Z20 (dust) YES
3Gas, vapourMistsDust
Normal level Level of protection required GROUP II Z2 (gas) / Z22 (dust) YES
operaTion in gazeous explosive aTMospHere
“Components” are called all parts that are essential to the safe operation of apparatus and protection systems, but which have no autonomous function.
Electrical equipment must conform to a type that has obtained a EC type examination certificate from on official body.
This certificate is issued when the equipment has satisfied the construction rule, the checks and tests required by the standards relating to the method of protection chosen.
ce MarKing coDesIt’s specified by 94/9/CE directing
Identification number of notified
body (LCIE)
II 2 GD0081
Equipment group for surface category
Atmosphere type Gas or Dust Use of equipment in
potentially explosive atmosphere
Equipment present zone 2
Certification body LCIE Product specifications X – U
Certificat n°
X05ATEX
X : precaution of useU : Certified component
equipMenTs for explosion risK aTMospHeres
Four rules must be respected in gazeous explosive atmosphere :
Equipment location zone Allowed categorie CETAL products
ZONE 0 1 G NO
ZONE 1 1G - 2G YES
ZONE 2 1G - 2G - 3G YES
1) Equipment group according to explosion protection degree2) Gas group and subdivision3) Temperature group4) Ambiant temperature : standard requirements from minus 20°C to plus 40°C
CETAL equipments are certified from minus 40°C to plus 60°C
Four rules must be respected in dusty explosive atmosphere :
Equipment location zone Allowed categorie Protection degree CETAL products
ZONE 20 1 D IP6X NO
ZONE 21 1D - 2D IP6X YES
ZONE 22Conductive dust 1D - 2D IP6X YES
Insulating dust 3D IP6X YES
1) Equipment group according to explosion protection degree2) Profing degree of equipment3) Surface temperature4) Ambiant temperature : standard requirements from
minus 20°C to plus 40°C
CETAL equipments are certified from minus 40°C to plus 60°C
operaTion in DusTY explosive aTMospHere
To meet industrial requirements, CETAL use protective mode “e” ( EN 60079-7 increased safety) and “d” (EN 60079-1 flameproof enclosures).
Protection mode by flame proof enclosure “d”The casing (enclosure) must contain the explosion, guarantee that the ignition cannot be propagated and have at every point a temperature lower than the self-ignition temperature of the
surrounding gases and vapours.The quality of the seal (cylindrical, flat, threaded), the length of the seal and of the clearance depend on the unobstructec capacity of the enclosure and
of the gas classified in a subdivision (according to CENELEC) or in a group (according to NEC) ; their values make the propagation of the ignition impossible in the atmosphere in question.
Protection mode by increased safety “e”This mode of protection is perfectly applicable to terminal enclosures. It consists of making impossible any appearance of an ignition source (electric
arc, rise in temperature) thanks to the use of high quality insulation material, dimensioned to the leakage paths and distance in the air and to
the quality of the electric connections. It should be noted that this method of protection is suited to all gas or vapour subdivisions.
cable glanDsAs far as possible, cables and accessoiries should be used so as not to expose them to mechanical damage, corrosive or chemical influences, or the effects of heat.
Where there is a risk, appropriate measures must be taken and the proper cables must be chosen (armourded cables with mineral insulation, with reinforced cross sections to limit the admissible current.) Knowledge of the
specific installation methods and instructions for each different country is essential. Unless otherwise specified, the cable glands are selected for non-reinforced cable.
All equipment for use in explosive atmospheres made and sold by Cetal have a certificate of conformity or component certficate. Furthermore, it complies with the new ATEX European Directive.
Protection mode “de”Combination of modes of protection by explosion proof enclosure and enhanced safety « de »There are different solutions for adapting the equipment to the conditions of installation : at the connecting terminals of the heating elements and the measuring equipment are mounted in an
explosion proof casing. The eletric connection is made inside an enhanced safety casing.All the terminals are placed in an increased safety casing. The certified type temperature control devices are located in a type « d » auxiliary casing.
ceTal offer
EEX
Use in surface industriesGas subdivision (IIA - IIB - IIC)
T6d IIC
Equipement complies with 1 type of protection standardisez by Cenelec
Portection used (ie-d-ia) available for Cetal product
Temperature class T1 to T6 for an ambient temperature
of 40°C
EC type examination certificate by notified body
• food industries • hydraulic power plant • nuclear power plant • heavy fuel oil power plant • fuel gas compressor • printing house • iron and steel industry • research laboratories • maintenance in temperature of fuel tank located outside • drilling platform • refinery • heating of hazardous premises •22
The heating assemblies duplicate-moulded with aluminium, cupronickel, brass, are fitted with Certified type explosion proof casings with temperature control by thermostat, limiter, temperature probe, integrated into the casing or mounted in an auxiliary casing.
MoulDeD eleMenTsEC type examination certificate : LCIE 04 ATEX 6094X
Certified for use in explosive atmospheres, according to the standard, Cetal industrial convectors are particulary suited to the heating of industrial premises, paining booths,
warehouses for inflammable goods, drilling platforms and sites. The convectors are certified EEXdIIC.
inDusTrial convecTors
rae eex d ii c T3 (200° c)
W Weight Kg L Ref. 500 15 395 RAE 05 T3* 1000 19 590 RAE 10 T3 1500 23 770 RAE 15 T3 2000 25 965 RAE 20 T3 3000 29 1340 RAE 30 T3
rae eex d ii c T4 (135° c)
W Weight Kg L Ref. 500* 15 590 RAE 05 T4* 1000* 19 965 RAE 10 T4 1500 23 1340 RAE 15 T4
Terminal enclosure EExdIIC
CG EX
Ribbed heating elements
Total length = L + 200
L
340
175
*Coupling mono
*Coupling mono
W Weight Kg L Ref.500 8,5 790 RBAE 05 T3 1000 13 1140 RBAE 10 T3 1600 16 1740 RBAE 15 T3 2000 21,5 1990 RBAE 20 T3
Terminal enclosure EExdIIC
CG EX
L
rbae eex d ii c T3 (200° c)
W Weight Kg L Ref.500 14 1290 RBAE 05 T4 1000 18 2230 RBAE 10 T4 1600 23 3390 RBAE 15 T4
rbae eex d ii c T4 (135° c)
These convectors consist of enamelled finned elements. The connection by cable gland is made of aluminium EEx casing (single or three-phase). The frame is made of coated steel or stainless steel. It may be fitted with a regulating thermostat integrated into the casing.
This product consists of a cylinder placed in a finned tube made of coated steel. The single phase connection by cable gland is made in the EEx casing.
Used in hazardous atmospheres for heating gas or liquids subject to natural convection or forced circulation, CETAL immersion heaters have certificates issued by the LCIE. They meet the requirements of the new European Directive 94/9/EC of 23.03.94 (ATEX) and standards (CENELEC). The different versions – immersion heaters with casings with a component certificate, immersion heaters with a certificate of conformity – the wide choice of possibilities and methods of protection, guarantee a solution suited to the customer’s requirements.
Immersion heaters for explosive atmospheres are equipped of stainless steel or incolloy armoured elements, generally hairpin-shaped, welded to the DIN/ASA standardized flanges according to procedures which have CODAP, TÜV and ASME approval.The watt density, ranging from 0.1 to 15 W/cm², is determined from the working parameters of the process and the exchange coefficients. For a maximum immersion length of 3300 mm, the power delivered by a flange immersion heater can reach several MW.
The electrical cabling in one or more paces gives access to several power steps. Connection blocks and rods are used to ensure the electrical connection.The array may be fitted with a temperature control system whereby the power and specific load are controlled by parameters such as flow rate, pressure, viscosity, temperature etc.
EC type examination certificate : Protect. “d” LCIE 07 ATEX 6004XProtect. “e” LCIE 01 ATEX 6041X
iMMersion HeaTers
These heaters are commonly used under low pressure (< 0.02 bar) and in forced convection for the heating of air conditioning air, of packing rooms, for the storage of hazardous goods or for the heating of air or gas (argon, nitrogen) in industrial processes located in classified zones.They are made from armoured elements spe-cially shaped and positioned to take advantage
of an outlet / useful volume ratio and a very high heat exchange.The temperature of the heating elements de-pends on the outlet temperature desired, on the surface watt density (W/cm²), on the nature of the fluid and its flow rate.The electrical connections are made inside one or more casings certified as conform for use in
hazardous atmospheres depending on the ver-sion chosen.
EC type examination certificate : “d-e” LCIE 01 ATEX 6044X
inDusTrial air DucT HeaTers
Forced circulation fluid heaters are particularly suited to the heating of liquids such as water, superheated water, heavy oil, fuels, oils and thermal fluids and to the heating of gases under pressure such as air, steam (superheater), nitro-gen, hydrogen, methane, etc.
Defined specifically for each industrial applica-tion, these heaters consist of one or more steel or stainless steel bodies linked hydraulically in se-ries and/or in parallel and meet the requirements conforming to the PED European Directive.
To prevent corrosion problems related to the working fluid and operation temperature, the
constituting elements of the heating array are built with the appropriate stainless steel. The heating elements and the bundle spacers are designed to obtain the optimal heat exchange coefficient. The heating array, with a maximum immersion length of 3300 mm, can be equipped with temperature control devices to regulate the sheath watt density (W/cm²) as a function of parameters such as fluid flow, pressure, visco-sity, fluid temperature, sheath skin temperature, etc…
Built in accordance with the construction co-des specified for the pressure and temperature
in question (CODAP, ASME, TEMA, STOOM-WEZEN…), these assemblies allow very high power ratings to be reached (= 2000 kW) and the controlling of circulation speeds, essen-tial characteristics for guaranteeing an excellent thermal exchange.
EC type examination certificate : LCIE 01 ATEX 6046X
process circulaTion HeaTers
EC type examination certificate : LCIE 01 ATEX 6042X
EC type examination certificate : LCIE 01 ATEX 6043X
proDucT range for HazarDous aTMospHeres
From -40° C to 20° C air dryer duct heater assembly - EExe - 6 x 2 m2 exchange surface - Power 240 kW
• food industries • hydraulic power plant • nuclear power plant • heavy fuel oil power plant • fuel gas compressor • printing house • iron and steel industry • research laboratories • maintenance in temperature of fuel tank located outside • drilling platform • refinery • heating of hazardous premises • 23www.cetal.com
peTrocHeMical
peTrocHeMical
Diesel oil proDucTion
cruDe oil WasTe TransporT
reffinerY
realizaTion exaMples
Air duct super heater 500 kW Calcination oven.
EExdIICAir ducted heater 3x 20 kW 1 bar maximal pressure in operation.
Air dryer circulation heaters assembly698 kg/h - 570 °C53 kW + 48 kW + 30 kW + 16 kWHazardous area
3.2 MW gathering station53 m3/h water / crude oilcirculation heater 82°C and 51 barghazardous area
528 kW - 480 Vac 3 PhCatalytic bed480°C regeneration circulation heater36’’ 150 lbs inconel flangehazardous area
agro-alimentaire • centrale de production d’énergie électrique • centrale nucléaire • centrale thermique au fuel lourd • compresseur de gaz naturel • imprimerie • industrie sidérurgique • laboratoires de recherche • maintien en températures de cuves de fuel situées à l’extérieur • plate-forme de forage • raffinerie9 agro-alimentaire • centrale de production d’énergie électrique • centrale nucléaire • centrale thermique au fuel lourd • compresseur de gaz naturel • imprimerie • industrie sidérurgique • laboratoires de recherche • maintien en températures de cuves de fuel situées à l’extérieur • plate-forme de forage • raffinerie• food industries • hydraulic power plant • nuclear power plant • heavy fuel oil power plant • fuel gas compressor • printing house • iron and steel industry • research laboratories • maintenance in temperature of fuel tank located outside • drilling platform • refinery • heating of hazardous premises •24
boron niTriD vHp HeaTing roDs
70° C electrical connection rods maximal temperature when energized. Nominal
diametermm
Connection rods
CouplingI maxi(A)
CU CR Nickel
8,21 Ph
105 /8,5 240 110
16
1 Ph 85 27,53 Ph 60 27,51 Ph with half 135 601 Ph with 60 27,53 Ph with 50 22,5
19
Ground circuit 240 1101 Ph 85 27,53 Ph 60 27,51 Ph with half 135 603 Ph with half 60 27,53 Ph with 50 22,5
TerMinal enclosure
is feeled up with twoo components compound to insure tightening.
according cable section
Ø33
ou
43
Aluminium enclosure with power cable gland
TYpe orgM ip 55 or ip 66
Aluminium enclosure with power cable gland
TYpe orpM ip 55 or ip 66
Diameter allowance : see boardLength allowance : according requirementsOptional : machined according requirements
helicoid machinedcold part 90° angled
with temperature sensor
Mecanical cHaracTerisTicsAVAILABLE MATERIALS
Austenilic steel Nickel alloy
AFNOR designation : Z3 CND 18-12-02 Z8 CN 25-20 Z8 NC75-15 Z3 NCDU 42-22AISO designation: 316 L 310 Inconel 600 Incoloy 825DIN designation : 1.4404 1.4845 2.4816 2.4858Usual diameters
8,2 *8,5 *16 * * * *19 * * * *
Max allowed T° C750° C 1050° C 1050° C 1000° C
Maximal allowed supply voltage : < 1000 VPower load variation :
not exceeding 500 W : ± 10 % beyond 5000 W ± 10 % / + 5 %
By nickeled CuNi rods : 30 mm length
By cable : HO7RNF (standard cables or according your requirements)
elecTrical cHaracTerisTics
Manufacturing of very high performance elements is the result of the research and development carried out by CETAL during the period 1986 -1987. This allowed the widening of the application perimeters of heating by the Joule effect which until then was by traditional armoured heating elements (insulation by electrical grade magnesium oxide).
The very high performance of these ele-ments are directly connected to the control of the manufacturing process :
- Positioning of the heating wire as close as possible to the sheath whilst guaran-teeing dielectric rigidity.- Compactness of the insulation (boron ni-tride) allowing heat transfer and providing electrical insulation when hot.
Boron nitride is used as an electrical insu-lator to produce stainless steel or incolloy tubular heating elements (diameter 10, 16 or 19 mm). These one- or three-phased elements can be equipped with a core-in-tegrated thermocouple. The watt density,
which depends on the operating condi-tions (convection, conduction and radia-tion) and on the elements sheath tempe-rature, can exceed 100 W/cm²
MeTallurgical cHaracTerisTics
sTainless sTeel enclosure
roTarY connexion enclosure
DiMensional cHaracTerisTics
agro-alimentaire • centrale de production d’énergie électrique • centrale nucléaire • centrale thermique au fuel lourd • compresseur de gaz naturel • imprimerie • industrie sidérurgique • laboratoires de recherche • maintien en températures de cuves de fuel situées à l’extérieur • plate-forme de forage • raffinerieagro-alimentaire • centrale de production d’énergie électrique • centrale nucléaire • centrale thermique au fuel lourd • compresseur de gaz naturel • imprimerie • industrie sidérurgique • laboratoires de recherche • maintien en températures de cuves de fuel situées à l’extérieur • plate-forme de forage • raffineriewww.cetal.com 10• food industries • hydraulic power plant • nuclear power plant • heavy fuel oil power plant • fuel gas compressor • printing house • iron and steel industry • research laboratories • maintenance in temperature of fuel tank located outside • drilling platform • refinery • heating of hazardous premises • 25www.cetal.com
(1) Stainless steel sheath quality is depending of the temperature and heated medium. The two milimetres sheath thickness gives strong and avoids buckling in hot conditions.
(2) Stainless steel cold end caps tight welded, according to approved welding procedure.
(3) High quality heating wires. Length, quantity and wiring are depending of the ohm value. melting temperature 1200° C.
(4) Electrical connection rods diameter according to current intensity.
(5) Powered Boron Nitride ensuring heat transfer and electrical connection.
Aluminium enclosure ATEX certified : LCIE 04 ATEX 0008U
TYpe broae90 ip67
Aluminium enclosure ATEX certified : LCIE 04 ATEX 0008U
TYpe broae130 ip67 TYpe brae55 ip66
Aluminium enclosure ATEX certified : LCIE 04 ATEX 0001U
MounTingThe very high preformance heating (VHP) mounting can be secured by sliding fitting (see
1) or screw-on (see 2) soldered flange (see 3) or machined mounting part (see 4).
Sleeve for sensor
Connection rods (4)
Flang - mounting part
Welded bottom (2)
Immersion lengthup to 5000 mm
wire NiCr 80/20 (3)
isolation (5)
Sheath (1) Ø mm : 16 - 19 Material : 310-316L inconnel 600 - incoloy
explosion proof enclosure
realizaTion exaMples
Fig. 1 Fig. 2 Fig. 3 Fig. 4
Air circulation heater with flow from 0,1 to 1Kg heated to 1000° C and 50 bars pressure.
Air Super heater at 1000°C16,5 KW.With VHP heating rods.
• food industries • hydraulic power plant • nuclear power plant • heavy fuel oil power plant • fuel gas compressor • printing house • iron and steel industry • research laboratories • maintenance in temperature of fuel tank located outside • drilling platform • refinery • heating of hazardous premises •26
CETAL can rely on for fifteen years of experience in the design and manu-facture of bolt heaters.
CETAL bolt heaters are specially desi-gned to deliver the maximum power to the heating part. CETAL has deve-loped Boron nitride insulation based
bolt heaters, to obtain watt densities that exceed 40 W/cm². These can be used indifferently for tightening / loo-sening of bolts, for thermal dilation of turbines, for pressure equipments, for drop-forge installations…
CETAL bolt heaters can be equipped with low-voltage connectors, cables, terminal enclosures, carrying han-dles. CETAL bolt heaters’ technology allows heating to be achieved in a few minutes, thus reducing down-time of pressure equipments and installa-tions considerably.
Mecanical cHaracTerisTicsTube quality : AISI 316L or other on requestOptional : cold part 90° angled
The bolt heater power is depending on the surface load and the clearance (bolt heater inside diameter / blot heater outside diameter)
BOLT HEATER ØIN MM
BOLT HOLE Ø RECOMMENDED H11
10,7 1111,7 1212,2 12,515,7 1617,7 1819,7 2021,65* 2224,6* 2529,6* 30
1 23
4
0
200
300
400
500
600
700
800
900
1000
1100
10 20 30 40 50 60 W/cm2
°C1 : clearance = 0,8 mm2 : clearance = 0,6 mm3 : clearance = 0,5 mm4 : clearance = 0,4 mm
Example : with 0,5 mm clearance and a 20 W/cm² suface load we will reach an 800° C sheath temperature.
expansion TigHTeningasseMbling HeaTing/expansion screWing cooling/TigHTenning
Die HeaTing/bolT HeaTers
principle DraWing
poWer Design anD surface loaD
HEATING LENGTH MARKS
CONNECTOR ENCLOSURE ALUWITH FEMALE CONTACT
POSITIONNING RING
HEATING LENGTH
ROD LENGTH
NOSE LENGTH COLD LENGTH
120
PHT PHT PHT
• food industries • hydraulic power plant • nuclear power plant • heavy fuel oil power plant • fuel gas compressor • printing house • iron and steel industry • research laboratories • maintenance in temperature of fuel tank located outside • drilling platform • refinery • heating of hazardous premises •www.cetal.com 27
DiMensional cHaracTerisTicsRods
nominal diametermm
Connecting rods
Coupling Max AMPS
10,7 (machining)ground circuit 1001 Ph 20
11,7ground circuit 1001 Ph 20
12,2ground circuit 1001 Ph 20
15,7 - 17,719,721,6524,6
ground circuit 2751 Ph 1003 Ph 100half diam. rods 160
29,6
Maximal allowed nominal voltage : < 1000 VPower load variation :
not exceeding 5000 W : ± 10 % beyond 5000 W : -10 % / + 5%
Electrical connections aluminium plugs for 24 and 48V
Cable :HO7RNF standard cable, or on request Silicone cable or other Terminal enclosure with handle (PHT)
connecTion 24/48 v connecTion 230 v - 400 v connecTion 230 v - 400 v
MounTing / accessoiriesPositioning ring diam. 30, diam. 40, or diam. 50 according to bolt heater diameter.Other on request according to specification.
Surface load : till 40 W/cm²Voltage : 24 V - 48 V - 110 V - 230 V - 400 or otherSheat : st. st. 321 - 310 - 316 L - incolloy - inconelUsual Ø : 11,7 - 12,2 - 17,7 - 19,7 - 21,65 - 24,6 - 29,6Length : heating or non heating on requestForm : straight or cold part cold 90° angled
TecHnical cHaracTerisTics
elecTrical cHaracTerisTics
bolT HeaTing pracTice
Do not use outdoors.
Aluminium plug HORNF standard cable, or on request Terminal enclosure with handle (PHT)
Care : check clearance.Check tension of connection.
Check the immersion length before energize Do not defuse under voltage. Check the surface state of the drilling.
YES
NO
YES
NO
YES
NO
YES
NO
YES
NO
YES
NO
The connection rods are always in copper chromnium for not going up to 90° C.
Certified quality and environmental management systems
Qualified, dynamic & forthcoming teams by your side
Partnerships with suppliers and subcontractors
Flexibility and effectiveness of processes
Products & services improvement and innovation
Customers satisfaction
42, rue des Aviateurs
BP 20037 - 67501 HAGUENAU CEDEX FRANCE
Tél. 0033 3 88 06 19 49 - Fax : 0033 3 88 06 19 30
http://www.cetal.com - e-mail : [email protected]
Capital : 201.600 e - RCS : Strasbourg - SIREN : 688 500 230 000 18 - NAF : 297 A
EUROPE
FRANCE
AMÉRIQUE DU NORD
AMÉRIQUE DU SUD
AFRIQUE
RUSSIE
ASIE
MOYEN-ORIENT
AUSTRALIE
The experience and competence of our engineering department and our high performance equipment enable us to offer a large range of electrothermical equipment (supply and maintenance). The company’s know-how and high quality products have strongly contributed to the development of its reputation in France and abroad.
Your are welcome on :www.cetal.com
We are at your disposal online.
IMp
RE
X -
200
8040
067
- 04
/08
Agents network in France, in Europe and worldwide