Philips Lighting UK Ltd, Guildord Lighting Proposal-NOT FOR CONSTRUCTION Page 1/12 LiDL Sprowston Carpark Ltg Results 20.07.16 Carpark Lighting Proposal Installation : LiDL Sprowston, Norwich Project number : Customer : LiDL Processed by : HSR / AGG Date : 05.08.2016 Project description: Maintenance Factor 0.73 No obstructions are considered in these lighting calculations. Lighting levels take into account approximated spill light from the stores sales area. Lighting levels 15Lux Ave with 25% uniformity. The nominal values shown in this report are the result of precision calculations, based upon precisely positioned luminaires in a fixed relationship to each other and to the area under examination. In practice the values may vary due to tolerances on luminaires, luminaire positioning, reflection properties and electrical supply. Lighting Proposal. See attached Appendix A. The following values are based on exact calculations on calibrated lamps, luminaires and their arrangement. In practice, gradual divergences can occur. Guarantee claims for luminaire data are excluded. Relux and the luminaire manufacturers accept no liability for consequential damage and damage which is occasioned to the user or to third parties.

Carpark Lighting Proposal - Broadland · Installation and Maintenance Notes 1) The proposal must be read in conjunction with all other relevant project drawings and specifications

  • Upload
    others

  • View
    7

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Carpark Lighting Proposal - Broadland · Installation and Maintenance Notes 1) The proposal must be read in conjunction with all other relevant project drawings and specifications

Philips Lighting UK Ltd, GuildordLighting Proposal-NOT FOR CONSTRUCTION

Page 1/12LiDL Sprowston Carpark Ltg Results 20.07.16

Carpark Lighting Proposal

Installation : LiDL Sprowston, Norwich

Project number :

Customer : LiDL

Processed by : HSR / AGG

Date : 05.08.2016

Project description:Maintenance Factor 0.73

No obstructions are considered in these lighting calculations.

Lighting levels take into account approximated spill light from the stores sales area.

Lighting levels 15Lux Ave with 25% uniformity.

The nominal values shown in this report are the result of precision calculations, based upon precisely positioned luminaires in a fixed relationship to each other and to the area under examination. In practice the values may vary due to tolerances on luminaires, luminaire positioning, reflection properties and electrical supply.

Lighting Proposal. See attached Appendix A.

The following values are based on exact calculations on calibrated lamps, luminaires and their arrangement. In practice, gradual divergences can occur.

Guarantee claims for luminaire data are excluded.

Relux and the luminaire manufacturers accept no liability for consequential damage and damage which is occasioned to the user or to thirdparties.

alell
20161382
Page 2: Carpark Lighting Proposal - Broadland · Installation and Maintenance Notes 1) The proposal must be read in conjunction with all other relevant project drawings and specifications

Philips Lighting

Philips Centre, Guildford Business Park, Guildford, Surrey GU2 8XH Tel: +44 (0) 845 6011283

Philips Electronics UK Limited Registered in England No. 446897 Registered office Philips Centre, Guildford Business Park Guildford, Surrey GU2 8XH www.philips.com

Lighting Proposal Terms and Conditions of Use These terms and conditions apply to any proposal(s) supplied by Philips Electronics UK Limited (“Philips”) to

which this document has been attached or accompanies, whether or not this is specifically acknowledged or

referenced within the proposal.

For the purposes of these terms and conditions a proposal (“proposal”) is understood to mean a CAD drawing,

lighting calculation, written document, verbal conversation, or in fact any medium used to demonstrate or

communicate a proposed lighting arrangement using Philips lighting products. A customer (“customer”) is the

person or organisation for whom the proposal is intended, whilst a design (“design”) or designer (“designer”)

should have the meaning set out in the Construction, Design and Management Regulations 2007.

General Statement The proposal has been provided in order to demonstrate how Philips lighting products could be arranged in order

to facilitate the requirements particular to the relevant project, and is therefore only a suggested lighting design.

This information is provided subject to the following limitations:

- Philips has not undertaken any risk assessment for this design. Philips will not be held liable for any risk

associated with the implementation of the design.

- Philips may not have had physical access to the site of the project to verify the information which has

been provided and the proposal is therefore based solely on information provided by the customer to

Philips. The customer is therefore responsible for ensuring that the proposal can be safely

implemented in compliance with any laws and regulations.

Accordingly, the information contained in the proposal does not constitute a design for the purposes of the

Construction, Design and Management Regulations 2007 and Philips does not accept or assume the role of

designer.

The nominal values described in the proposal are likely to have been as a result of precision calculations, based

upon precisely positioned luminaires in a fixed relationship to each other and to the area under examination

which is usually considered to be a flat surface with no solid obstructions. In practice the values may vary due to

a number of tolerances including; positions of lamps, luminaires, gear/drivers, ambient temperature, electrical

supply behaviours, road camber, surface reflections, obstructions, and the precise positioning and angle of the

luminaires for example.

The proposal should be considered as guidance only and must not be used in place of the final principal or

construction drawings. Philips recommends that in the event that this proposal is taken forward as the preferred

solution, that the calculations and arrangements are first scrutinised, verified and approved by a suitably qualified

designer before being transposed onto the relevant working drawings as appropriate.

Appendix A

Page 3: Carpark Lighting Proposal - Broadland · Installation and Maintenance Notes 1) The proposal must be read in conjunction with all other relevant project drawings and specifications

Installation and Maintenance Notes 1) The proposal must be read in conjunction with all other relevant project drawings and specifications.

2) Do not scale from the proposal. If in doubt please request further information.

3) The proposal may show lighting layout information, but should not be used for installation purposes or

construction drawings. Please refer to the official contractor’s working drawings which should also include

additional information such as electrical connections, other illuminated equipment, and site specific hazards

and other safety considerations.

4) All relevant laws and regulations must be fully complied with including the undertaking of any required site

risk assessments before installation commences.

5) The proposal is based upon customer supplied information and it should be assumed that no survey on site

has been carried out by Philips. Utility information such as underground and over ground cables and gas

pipes etc. will need to be checked on site by the appropriate person/organisation before any excavation

works or installation of lighting equipment.

6) The proposal may contain symbols which indicate the proposed locations of the lighting equipment. For

further information please refer to the luminaire schedules and details.

7) Locations and orientation of all equipment must be confirmed with the client prior to installation. Exact

orientation of luminaires may need to be finalised during final focusing. Please refer to the Philips lighting

solutions drawings and specifications for details of electrical engineering associated with lighting works.

8) The customer shall ensure that all proposed lighting equipment is suitable for the particular environmental

conditions prevalent at the proposed location.

9) All lighting equipment must be supplied with adequate means for protection during transport to site and any

subsequent storage prior to installation.

10) For lighting on structures such as bridges, tunnels, buildings, canopies, furniture or water features for

example, please refer to the relevant drawings and details.

11) For details of all luminaires please refer to the Philips lighting solutions luminaire schedule.

12) For cable routes, driver locations and any electrical works associated with the lighting installation please

refer to the contractor’s installation drawings and documentation.

13) The lighting installation requires a variety of luminaire types to achieve the desired effects. Information has

been provided on the proposal as general guidance and outline of good practice. For more specific

recommendations please refer to manufacturer’s details for application, operation, handling cleaning and

disposal instructions.

14) Installation and maintenance of lighting equipment installed at any height above ground requires specific

precautions to be taken. Access arrangements should be in strict accordance with the projects access report,

method statement and health and safety guidelines.

15) All fixtures must be electrically isolated prior to any testing or maintenance.

16) Luminaries may need to be powered up for focusing during the hours of darkness, and in which case they

must be specified as being fully enclosed and earthed, or operated at extra low voltage.

17) Certain lighting fixtures need to be protected from thermal damage caused by over heating by means of

thermal cut-out or similar device. Please refer to the relevant documentation.

Page 4: Carpark Lighting Proposal - Broadland · Installation and Maintenance Notes 1) The proposal must be read in conjunction with all other relevant project drawings and specifications

Table of contents

ObjectInstallationProject numberDate

: Carpark Lighting Proposal: LiDL Sprowston, Norwich:: 05.08.2016

Philips Lighting UK Ltd, GuildordLighting Proposal-NOT FOR CONSTRUCTION

Page 2/12LiDL Sprowston Carpark Ltg Results 20.07.16

First Page 1Table of contents 21 Carpark1.1 Description, Carpark1.1.1 Luminaire data/Room elements 31.1.2 Floor plan 51.2 Summary, Carpark1.2.1 Result overview, Carpark 61.2.2 Result overview, Lorry Bay 82 Carpark Spill Light2.1 Summary, Carpark Spill Light2.1.1 Result overview, Evaluation area 1 102.2 Calculation results, Carpark Spill Light2.2.1 Pseudo colours, Reference plane 1.1 (E) 12

Page 5: Carpark Lighting Proposal - Broadland · Installation and Maintenance Notes 1) The proposal must be read in conjunction with all other relevant project drawings and specifications

1 Carpark

1.1 Description, Carpark

1.1.1 Luminaire data/Room elements

ObjectInstallationProject numberDate

: Carpark Lighting Proposal: LiDL Sprowston, Norwich:: 05.08.2016

Philips Lighting UK Ltd, GuildordLighting Proposal-NOT FOR CONSTRUCTION

Page 3/12LiDL Sprowston Carpark Ltg Results 20.07.16

Product data:

Type No.\Make

Philips Lighting1 9 Order No. : !Luminaire Ref: LL-E

Luminaire name : WT460C L1300 1xLED23S/840 WBEquipment : 1 x LED23S/840/- 22 W / 2600 lm

2 16 Order No. : !Luminaire name : TMS122 1xTL5-35W HFPEquipment : 1 x TL5-35W/840 39 W / 1000 lm

3 2 Order No. : !Luminaire Ref: LL-CANOPYLuminaire name : BBS490 1xDLED-4000 PGEquipment : 1 x DLED-4000 33.5 W / 2260 lm

4 20 Order No. : !Lantern Ref: LL-B42Luminaire name : BGP303 LED49-3/740PSR I DWL 42/LIDL7024 (6m MH COL)Equipment : 1 x LED49/740/- 56.9 W / 5040 lm

Centre point Rotation angle Target coordinatesNo. X [m] Y [m] Z [m] Z [°] C0 [°] C90 [°] Xa [m] Ya [m] Za [m]Philips Lighting WT460C L1300 1xLED23S/840 WB !Luminaire Ref: LL-E

1.1 190.49 212.93 2.70 321.00 0.00 -90.00 -- -- -- 1.2 186.91 208.50 2.70 321.00 0.00 -90.00 -- -- -- 1.3 183.32 204.07 2.70 321.00 0.00 -90.00 -- -- -- 1.4 179.73 199.64 2.70 321.00 0.00 -90.00 -- -- -- 1.5 176.14 195.21 2.70 321.00 0.00 -90.00 -- -- -- 1.6 172.56 190.78 2.70 321.00 0.00 -90.00 -- -- -- 1.7 168.97 186.35 2.70 321.00 0.00 -90.00 -- -- -- 1.8 165.38 181.92 2.70 321.00 0.00 -90.00 -- -- -- 1.9 161.80 177.49 2.70 321.00 0.00 -90.00 -- -- --

Philips Lighting TMS122 1xTL5-35W HFP ! 2.1 130.96 194.19 1.20 51.65 0.00 0.00 130.96 194.19 0.00 2.2 132.69 192.83 1.20 51.65 0.00 0.00 132.69 192.83 0.00 2.3 134.41 191.46 1.20 51.65 0.00 0.00 134.41 191.46 0.00 2.4 136.14 190.10 1.20 51.65 0.00 0.00 136.14 190.10 0.00 2.5 137.86 188.73 1.20 51.65 0.00 0.00 137.86 188.73 0.00 2.6 139.59 187.37 1.20 51.65 0.00 0.00 139.59 187.37 0.00 2.7 141.31 186.00 1.20 51.65 0.00 0.00 141.31 186.00 0.00 2.8 143.04 184.64 1.20 51.65 0.00 0.00 143.04 184.64 0.00 2.9 144.76 183.27 1.20 51.65 0.00 0.00 144.76 183.27 0.00

2.10 146.49 181.91 1.20 51.65 0.00 0.00 146.49 181.91 0.00 2.11 148.22 180.54 1.20 51.65 0.00 0.00 148.22 180.54 0.00 2.12 149.94 179.18 1.20 51.65 0.00 0.00 149.94 179.18 0.00 2.13 151.67 177.81 1.20 51.65 0.00 0.00 151.67 177.81 0.00 2.14 153.39 176.45 1.20 51.65 0.00 0.00 153.39 176.45 0.00 2.15 155.12 175.08 1.20 51.65 0.00 0.00 155.12 175.08 0.00

24 158.57 176.04 3.00 321.74 0.00 0.00 158.57 176.04 0.00Philips Lighting BBS490 1xDLED-4000 PG !Luminaire Ref: LL-CANOPY

22 155.08 171.82 3.00 0.00 0.00 0.00 155.08 171.82 0.00

Page 6: Carpark Lighting Proposal - Broadland · Installation and Maintenance Notes 1) The proposal must be read in conjunction with all other relevant project drawings and specifications

1 Carpark

1.1 Description, Carpark

1.1.1 Luminaire data/Room elements

ObjectInstallationProject numberDate

: Carpark Lighting Proposal: LiDL Sprowston, Norwich:: 05.08.2016

Philips Lighting UK Ltd, GuildordLighting Proposal-NOT FOR CONSTRUCTION

Page 4/12LiDL Sprowston Carpark Ltg Results 20.07.16

23 156.74 172.03 3.00 0.00 0.00 0.00 156.74 172.03 0.00Philips Lighting BGP303 LED49-3/740PSR I DWL 42/LIDL7024 (6m MH COL) !Lantern Ref: LL-B42 1 124.28 178.86 6.00 321.29 15.00 0.00 128.31 183.88 0.00 2 123.01 177.27 6.00 141.29 10.00 0.00 119.63 173.05 0.00 3 143.90 163.04 6.00 321.29 15.00 0.00 147.92 168.06 0.00 4 142.62 161.45 6.00 141.29 10.00 0.00 139.24 157.23 0.00 5 173.21 165.58 6.00 51.13 15.00 0.00 168.20 169.62 0.00 6 113.43 165.55 6.00 321.29 10.00 0.00 116.81 169.77 0.00 7 112.15 163.96 6.00 141.29 15.00 0.00 108.13 158.94 0.00 8 133.73 149.40 6.00 321.29 10.00 0.00 137.10 153.62 0.00 9 132.45 147.81 6.00 141.29 15.00 0.00 128.43 142.79 0.00 10 99.72 155.11 6.00 321.29 15.00 0.00 103.75 160.13 0.00 11 98.45 153.52 6.00 141.29 15.00 0.00 94.42 148.50 0.00 12 162.24 151.97 6.00 51.13 15.00 0.00 157.23 156.01 0.00 14 130.61 131.35 6.00 349.70 10.00 0.00 131.57 136.67 0.00 15 151.60 137.96 6.00 51.13 15.00 0.00 146.59 142.00 0.00 16 86.69 139.95 6.00 349.70 10.00 0.00 87.66 145.26 0.00 17 83.24 160.10 6.00 223.77 10.00 0.00 86.97 156.20 0.00 18 99.65 175.62 6.00 223.70 10.00 0.00 103.39 171.71 0.00 19 118.03 192.57 6.00 223.70 10.00 0.00 121.76 188.66 0.00 20 187.27 184.51 6.00 66.77 15.00 0.00 181.36 187.05 0.00 21 108.74 135.88 6.00 349.70 10.00 0.00 109.71 141.20 0.00

Structural elements

Virtual measuring surfaceRotation angle

No. xm[m] ym[m] zm[m] Length Width z axis L axis Q axisCarparkm 1 75.82 153.46 0.00 125.38 122.74 42.83 0.00 0.00Lorry Baym 2 179.33 195.83 0.00 18.33 20.37 50.81 0.00 0.00

OthersRotation angle

No. xm[m] ym[m] zm[m] Length Width z axis L axis Q axisA 1 127.14 193.74 0.00 76.44 78.67 48.95 0.00 0.00A 2 152.29 173.56 3.00 6.80 6.83 321.57 0.00 0.00

Page 7: Carpark Lighting Proposal - Broadland · Installation and Maintenance Notes 1) The proposal must be read in conjunction with all other relevant project drawings and specifications

1.1 Description, Carpark

1.1.2 Floor plan

ObjectInstallationProject numberDate

: Carpark Lighting Proposal: LiDL Sprowston, Norwich:: 05.08.2016

Philips Lighting UK Ltd, GuildordLighting Proposal-NOT FOR CONSTRUCTION

Page 5/12LiDL Sprowston Carpark Ltg Results 20.07.16

80 100 120 140 160 180 200[m]

140

160

180

200

220

240[m]

N

Page 8: Carpark Lighting Proposal - Broadland · Installation and Maintenance Notes 1) The proposal must be read in conjunction with all other relevant project drawings and specifications

1 Carpark

1.2 Summary, Carpark

1.2.1 Result overview, Carpark

ObjectInstallationProject numberDate

: Carpark Lighting Proposal: LiDL Sprowston, Norwich:: 05.08.2016

Philips Lighting UK Ltd, GuildordLighting Proposal-NOT FOR CONSTRUCTION

Page 6/12LiDL Sprowston Carpark Ltg Results 20.07.16

80 100 120 140 160 180 200[m]

140

160

180

200

220

240[m]

N

7.5 10 15 20 30Illuminance [lx]

GeneralCalculation algorithm used Average indirect fractionHeight of evaluation surface 0.00 mMaintenance factor 0.73

Total luminous flux of all lamps 144720 lmTotal power 2027 WTotal power per area (18405.37 m²) 0.11 W/m²

IlluminanceAverage illuminance Eav 14.5 lxMinimum illuminance Emin 4.5 lxMaximum illuminance Emax 30.7 lxUniformity Uo Emin/Em 1:3.19 (0.31)Diversity Ud Emin/Emax 1:6.75 (0.15)

Type No.\Make

Philips Lighting1 9 Order No. : !Luminaire Ref: LL-E

Luminaire name : WT460C L1300 1xLED23S/840 WBEquipment : 1 x LED23S/840/- 22 W / 2600 lm

2 16 Order No. : !Luminaire name : TMS122 1xTL5-35W HFPEquipment : 1 x TL5-35W/840 39 W / 1000 lm

Page 9: Carpark Lighting Proposal - Broadland · Installation and Maintenance Notes 1) The proposal must be read in conjunction with all other relevant project drawings and specifications

1 Carpark

1.2 Summary, Carpark

1.2.1 Result overview, Carpark

ObjectInstallationProject numberDate

: Carpark Lighting Proposal: LiDL Sprowston, Norwich:: 05.08.2016

Philips Lighting UK Ltd, GuildordLighting Proposal-NOT FOR CONSTRUCTION

Page 7/12LiDL Sprowston Carpark Ltg Results 20.07.16

3 2 Order No. : !Luminaire Ref: LL-CANOPYLuminaire name : BBS490 1xDLED-4000 PGEquipment : 1 x DLED-4000 33.5 W / 2260 lm

4 20 Order No. : !Lantern Ref: LL-B42Luminaire name : BGP303 LED49-3/740PSR I DWL 42/LIDL7024 (6m MH COL)Equipment : 1 x LED49/740/- 56.9 W / 5040 lm

Page 10: Carpark Lighting Proposal - Broadland · Installation and Maintenance Notes 1) The proposal must be read in conjunction with all other relevant project drawings and specifications

1.2 Summary, Carpark

1.2.2 Result overview, Lorry Bay

ObjectInstallationProject numberDate

: Carpark Lighting Proposal: LiDL Sprowston, Norwich:: 05.08.2016

Philips Lighting UK Ltd, GuildordLighting Proposal-NOT FOR CONSTRUCTION

Page 8/12LiDL Sprowston Carpark Ltg Results 20.07.16

80 100 120 140 160 180 200[m]

140

160

180

200

220

240[m]

N

10 15 20 30 50Illuminance [lx]

GeneralCalculation algorithm used Average indirect fractionHeight of evaluation surface 0.00 mMaintenance factor 0.73

Total luminous flux of all lamps 144720 lmTotal power 2027 WTotal power per area (18405.37 m²) 0.11 W/m²

IlluminanceAverage illuminance Eav 21.0 lxMinimum illuminance Emin 10.6 lxMaximum illuminance Emax 30.8 lxUniformity Uo Emin/Em 1:1.98 (0.5)Diversity Ud Emin/Emax 1:2.9 (0.34)

Type No.\Make

Philips Lighting1 9 Order No. : !Luminaire Ref: LL-E

Luminaire name : WT460C L1300 1xLED23S/840 WBEquipment : 1 x LED23S/840/- 22 W / 2600 lm

2 16 Order No. : !Luminaire name : TMS122 1xTL5-35W HFPEquipment : 1 x TL5-35W/840 39 W / 1000 lm

Page 11: Carpark Lighting Proposal - Broadland · Installation and Maintenance Notes 1) The proposal must be read in conjunction with all other relevant project drawings and specifications

1.2 Summary, Carpark

1.2.2 Result overview, Lorry Bay

ObjectInstallationProject numberDate

: Carpark Lighting Proposal: LiDL Sprowston, Norwich:: 05.08.2016

Philips Lighting UK Ltd, GuildordLighting Proposal-NOT FOR CONSTRUCTION

Page 9/12LiDL Sprowston Carpark Ltg Results 20.07.16

3 2 Order No. : !Luminaire Ref: LL-CANOPYLuminaire name : BBS490 1xDLED-4000 PGEquipment : 1 x DLED-4000 33.5 W / 2260 lm

4 20 Order No. : !Lantern Ref: LL-B42Luminaire name : BGP303 LED49-3/740PSR I DWL 42/LIDL7024 (6m MH COL)Equipment : 1 x LED49/740/- 56.9 W / 5040 lm

Page 12: Carpark Lighting Proposal - Broadland · Installation and Maintenance Notes 1) The proposal must be read in conjunction with all other relevant project drawings and specifications

2 Carpark Spill Light

2.1 Summary, Carpark Spill Light

2.1.1 Result overview, Evaluation area 1

ObjectInstallationProject numberDate

: Carpark Lighting Proposal: LiDL Sprowston, Norwich:: 05.08.2016

Philips Lighting UK Ltd, GuildordLighting Proposal-NOT FOR CONSTRUCTION

Page 10/12LiDL Sprowston Carpark Ltg Results 20.07.16

80 100 120 140 160 180 200[m]

120

140

160

180

200

220

240[m]

N

0.5 1 2 3 5 7 10 15 20Illuminance [lx]

GeneralCalculation algorithm used Average indirect fractionMaintenance factor 1.00

Total luminous flux of all lamps 144720 lmTotal power 2027.0 WTotal power per area (20002.49 m²) 0.10 W/m² (1.76 W/m²/100lx)

Evaluation area 1 Reference plane 1.1Horizontal

Em 5.8 lxEmin 0.00 lxEmin/Eav (Uo) 0.00Emin/Emax (Ud) 0.00Position 0.00 m

Type No.\Make

Philips Lighting1 9 Order No. : !Luminaire Ref: LL-E

Luminaire name : WT460C L1300 1xLED23S/840 WBEquipment : 1 x LED23S/840/- 22 W / 2600 lm

2 16 Order No. : !Luminaire name : TMS122 1xTL5-35W HFPEquipment : 1 x TL5-35W/840 39 W / 1000 lm

Page 13: Carpark Lighting Proposal - Broadland · Installation and Maintenance Notes 1) The proposal must be read in conjunction with all other relevant project drawings and specifications

2 Carpark Spill Light

2.1 Summary, Carpark Spill Light

2.1.1 Result overview, Evaluation area 1

ObjectInstallationProject numberDate

: Carpark Lighting Proposal: LiDL Sprowston, Norwich:: 05.08.2016

Philips Lighting UK Ltd, GuildordLighting Proposal-NOT FOR CONSTRUCTION

Page 11/12LiDL Sprowston Carpark Ltg Results 20.07.16

3 2 Order No. : !Luminaire Ref: LL-CANOPYLuminaire name : BBS490 1xDLED-4000 PGEquipment : 1 x DLED-4000 33.5 W / 2260 lm

4 20 Order No. : !Lantern Ref: LL-B42Luminaire name : BGP303 LED49-3/740PSR I DWL 42/LIDL7024 (6m MH COL)Equipment : 1 x LED49/740/- 56.9 W / 5040 lm

Page 14: Carpark Lighting Proposal - Broadland · Installation and Maintenance Notes 1) The proposal must be read in conjunction with all other relevant project drawings and specifications

2 Carpark Spill Light

2.2 Calculation results, Carpark Spill Light

2.2.1 Pseudo colours, Reference plane 1.1 (E)

ObjectInstallationProject numberDate

: Carpark Lighting Proposal: LiDL Sprowston, Norwich:: 05.08.2016

Philips Lighting UK Ltd, GuildordLighting Proposal-NOT FOR CONSTRUCTION

Page 12/12LiDL Sprowston Carpark Ltg Results 20.07.16

80 100 120 140 160 180 200[m]

120

140

160

180

200

220

240[m]

N

0.5 1 2 3 5 7 10 15 20Illuminance [lx]

Height of the reference plane: 0.00 m

Average illuminance Eav : 6 lxMinimum illuminance Emin : 0 lxMaximum illuminance Emax : 161 lxUniformity Uo Emin/Eav : 1 : 2175.96 (0.00)Diversity Ud Emin/Emax : 1 : 60585.13 (0.00)