    Protection and control

    Smart earth leakage protection

    P.1/2

  • 8/11/2019 Ca_P1_03

    2/42

    Smart earth leakage protection

    P.1/2

    /2-2

    Introduction 5

    P.1 - Industrial earth leakage protection

    Product selection table 13

    WG

    Earth leakage transformers, WG series 15

    RGE / RGE-R

    Electronic earth leakage relay with external transformer of the WGSeries 16

    RGU-10 / RGU-10 C

    Electronic earth leakage relay with external transformer of the WGSeries 18

    CBS-4 / CBS-4 C

    Earth leakage monitoring and signaling unit of the external transformer of the WGSeries 20

    CBS-8

    Earth leakage monitoring and signaling unit of the external transformer of the WG / WGPSeries 22

    WGP

    Earth leakage Transformers of the WGPSeries (only for CBS-8) 24

    WN

    Earth leakage transformers, WN series 25

    RN / RN-R

    Electronic earth leakage relay with external transformer of the WNSeries 26

    RN-10

    Electronic earth leakage relay with external transformer of the WNSeries 28

    WRU

    Earth leakage relay with built-in transformer (type A) 30

    WGBUTransformer with built-in earth leakage relay 32

    WRN-22

    Earth leakage relay with built-in transformer 35

    Relation between products and accessories 37

    P2- Self-reclosing overload and earth leakage protection

    Earth leakage protection and self-reclosing

    REC2

    Self-reclosing earth leakage relay P2-47

  • 8/11/2019 Ca_P1_03

    3/42

    Earth leakage protection P.1/2

    P1/2-5

    The "protection" and "continuity" of the

    electrical power supply are two terms

    that must not be separated if we wish to

    guarantee the safety of users and elec-

    trical installations.

    The recent addition of receivers or loads

    that generate distortion in the electricity

    grid (speed variators, electronic start-

    up units, computer equipment, lighting

    with electronic ballasts, etc.) has made

    necessary the use of protection systems

    that can distinguish between defects in

    the installation and the electrical altera-

    tions that cause the unwanted tripping

    of protection systems.

    The new range of earth leakage pro-

    tection products offers state-of-the-art

    performance to guarantee the continuity

    and safety requirements:

    Smart earth leakage protection

    } Monitoring in true root mean square.

    } High frequency ltering

    } Inverse curve delay (instantaneous

    and selective)

    } Adjustment of the nominal sensitivity

    trigger

    } Display of the fault current (monitor-

    ing of protection systems)

    Monitoring the status of protections al-

    lows us to do the following in the electri-

    cal installation:

    } Analyse the insulation conditions.

    } Preventive and corrective mainte-

    nance.

    } Reduce production downtime. De-crease maintenance costs. Quick loca-

    tion of faults.

    P.1/2

    Protection

    Immunised protection

    Immunised protection

    Monitoring

    Immunised protection

    Monitoring

    Remote control

    Reset

    4 earth leakage protection methods

    SAFETY OF

    PERSONS AND

    MATERIALS

    SAFETY OF

    PERSONS AND

    MATERIALS

    CONTINUITY

    ELECTRICAL

    POWER SUPPLY

  • 8/11/2019 Ca_P1_03

    4/42

    .1/2 Earth leakage protectionP

    1/2-6

    When the earth leakage protection sys-

    tem detects a fault current, it acts on the

    electrical installation being protected,

    opening the circuit while interrupting

    the supply of electrical energy, thus pre-

    venting the danger of electrocution for

    persons when the fault current reaches

    dangerous values, either as a result of

    direct or indirect contact, including any

    potential damage caused to goods and

    materials.

    An earth leakage protection system is

    composed of three clearly different parts:

    } Detecting element or sensor

    } Relay} Circuit breaker

    Detecting element or sensor: Cur-

    rent transformer that detects the earth

    leakage current of active conductors in

    an installation, sending a proportional

    signal to the relay. It can have a toroidal

    or rectangular geometry, depending on

    the arrangement of plates or the wiring

    of the installation location.

    The correct operation of the sensor re-

    quires the path of capacitors to be as

    perfectly aligned as possible.

    Relay: Smart protection element. It

    measures and treats the signal received

    Denition

    Nowadays, "sympathy" or unwanted

    triggers are quite common in modern in-

    stallations. In these cases, one or more

    earth leakage switches are triggered si-multaneously, protecting an installation

    from the leakage currents sent to earth

    as a result of capacitive effects caused

    by the installation.

    Said capacitive effects can explained by

    two reasons:

    } The installation's cables cause earth-

    ing condensation effects. The longer the

    cable, the greater the capacity effect

    } The capacitors of EMI lters in the

    equipment with electronic power regula-

    tion

    Immunised earth leakage protection

    by the sensor and either sends the trigger

    signal to the associated circuit breaker

    or not, depending on the sensitivity and

    delay time values programmed.

    Circuit breaker: This element acts as

    the current interrupting element. It can

    be a circuit breaker (with trigger coil), a

    contact, etc.

    These three elements can be found in

    CIRCUTOR's products with different

    congurations:

    } All elements separately

    } Relay with internal transformer

    The different loads or consumption of an

    installation can be classied in two main

    groups, depending on the type of insula-

    tion from earth:

    Loads with no earthed capacitors

    The insulation existing between the unit

    and the earthing elements can be rep-

    resented with a pure Ohmic resistance.

    If the resistance is not high enough, no

    current will pass through the earthing

    elements. The leakage current is zero

    (current passing to earth under normal

    conditions).

    In case there is an insulation fault, cur-

    rent will pass through earthing elements,

    the so-called fault earthed current, Id.

  • 8/11/2019 Ca_P1_03

    5/42

    Earth leakage protection P.1/2

    P1/2-7

    In this case, we must simply adjust the

    sensitivity and delay time to guarantee

    the adequate protection.

    Loads with earthed capacitors

    The current passes through the earthing

    elements as a result of the unit's opera-

    tions through its capacitors. In addition,

    the length of cables in an electrical in-

    stallation can lead to capacitive earthing

    faults, which would lead to this situation.

    The current can be injected with two

    methods:

    Permanent Leakages.

    The unit injects current in the earthingelements permanently. This type of be-

    haviour is closely tied to the use of EMI

    lters, which are installed in most ma-

    chines or loads with electronic power

    regulation, in order to comply with the

    electromagnetic compatibility directives.

    This type of lter prevents the high fre-

    quency distortion generated by the re-

    ceiver from being returned to the grid.

    However, it is transferred through the

    earthing capacitors. It also transfers in-

    directly the fundamental frequency and

    its corresponding harmonics, so that the

    leakage is usually a set of overlapping

    high and low frequency signals. There-

    fore, it increases the risk of an earth

    leakage trip with no real earth leakage

    current.

    Transient Leakages.

    It has the same capacitive effects of ca-

    bles and the lters mentioned above for

    transient overvoltages caused by grid

    switching effects, the connection-dis-

    connection of circuits or effects that are

    simply caused by atmospheric agents.

    In case of loads with earthed capaci-

    tors, the basic problem for the protec-

    tion of the system is to distinguish whichearthed current is part of the unit's op-

    eration and which is part of an insulation

    defect. Electromechanical earth leak-

    age relays do not usually solve these

    situations.

    The immunised earth leakage protection offered by CIRCUTORhas evolved in relation

    to ve factors, in order to satisfy the needs of our customers, catering for the current

    demand as regards the safety and continuity of the supply of electricity:

    } MEASUREMENT IN TRUE ROOT MEAN SQUARE (TRMS) AND CLASS A

    } IMMUNE TO TRANSIENT LEAKAGES

    } HIGH FREQUENCY FILTERING

    } ADJUSTMENT OF THE TRIGGER OF In

    } INVERSE CURVE

  • 8/11/2019 Ca_P1_03

    6/42

    .1/2 Earth leakage protectionP

    1/2-8

    Measurement in TRMS and Class A

    The voltage and current wave shapes

    have stopped being complete sine

    waves since the loads distributed in the

    installations are not linear. The continu-

    ous and harmonic components can dis-

    tort the wave shapes, whereby it will be

    necessary to take more accurate meas-

    urements.

    The current range of electronic earth

    leakage switches measures the root-

    mean-square-value (TRMS) of leakage

    currents by sampling it.

    The wave shapes in installations with

    linear resistive loads are pure sine-

    waves. However, the gure shows howthe mean value will not work to measure

    the root-mean-square-value with ac-

    curacy when it stops being a complete

    sine-wave.

    In accordance with these problems,

    the IEC 61008-1 Earth Leakage Switch

    Standard determines the types of op-

    eration, depending on the type of wave.

    Two types are dened, Class AC and

    Class A.

    CLASS AC

    The earth leakage devices used in do-

    mestic installations or that protect loads

    that do not cause distortions can be of

    the AC Type. These devices are marked

    with a symbol, in compli-

    ance with the IEC 61008-1

    Standard.

    CLASS A

    In the presence of non-linear receivers,

    Type A earth leakage protection sys-

    tems must be used, which means that

    rectied currents can be measured with

    a continuous component of up to 6 mA,

    including non-distorted currents (AC

    type), marked by the cor-

    responding IEC 61008-1

    Standard.

    The IEC61008-1Standard denes two

    types of ray-type curves to check thecorrect operation of an earth leakage

    device: an overload and an overvolt-

    age wave. The overload wave shows

    the effects caused in the measurement

    of the earth leakage device and the ov-

    ervoltage wave shows the effects in the

    power supply.

    Immunity against transient leakages

    The behaviour of earth leakage pro-

    tection units in the case of transientoverloads and overvoltages is vital to

    maintain the continuity in the supply of

    electricity. Therefore, the immunised

    earth leakage protection relays manu-

    factured by CIRCUTOR can support

    very high peaks.

    Voltage: Curve 1.2 / 50 s: 4 kV

    Current: Curve 8 / 20 s: 5 kA

  • 8/11/2019 Ca_P1_03

    7/42

    Earth leakage protection P.1/2

    P1/2-9

    High-frequency current

    Adjustments of In

    The IEC 479-1/ UNE 20-572-92Stand-

    ard describes the effects of currents

    passing through the human body for

    a frequency of 50 Hz. As you can see,

    the effect depends on the root-mean-

    square-value of the current passing

    through the body and the time it takes

    to pass through. In accordance with the

    effects, we can establish zones 1 (zone

    with no perception) and 2 (perception

    zone) as safe work zones. Therefore, in

    terms of the protection of persons, earth

    leakage protection systems must act on

    those zones.

    When the frequency increases, the

    curves are displaced to the right of the

    a.Perception threshold

    b."No-drop" threshold

    c1 / c2 / c3. Fibrilation threshold

    1.No perception

    2.Perception

    3.Reversible effects. Muscle tetany

    4.Potentially irreversible effectsDelaytime

    Sensitivity

    FrequencyfactorF

    f

    Frequency f

    The following graphs show that with an

    identical evolution of the fault earthed

    current in the same installation, the be-

    haviour of the earth leakage switch is

    different, even when the sensitivity level

    of Inis the same in both cases.

    This adjustment of In

    allows us to con-

    centrate more loads that incorporate

    earthed capacitors within the same line

    being protected. For example, in a com-

    puter installation: Each unit diverts a

    current, Ileakage

    , of 2 mA through the EMI

    lter capacitors included. At a sensitiv-

    ity of (In

    ) 30 mA, you can install 7 com-

    puters with the electromechanical earth

    leakage switches. However, if you use

    CIRCUTOR's electronic switches youcan install a total of 12.

    FaultearthedcurrentI

    d

    100 % In

    50 % In

    Time, t

    Faultea

    rthedcurrentI

    d

    100 % In

    85 % In

    Time, t

    The IEC 61008-1 Standard species

    that earth leakage switches must be

    triggered when the fault earthed current

    is between 50% and 100% of the sen-

    sitivity value (In

    ) selected. This means

    that the values that exceed 50% canset off the earth leakage switch trig-

    ger. This type of case is common with

    electromechanical switches. In the case

    of electrical energy installations, these

    have evolved in such a way that the ad-

    justment of protection can cause great

    problems, since it is too low. The elec-

    tronic earth leakage protection systems

    offered by CIRCUTOR determine the

    trigger near 100 % of In

    .

    Therefore, we have a lower risk of trig-gers and less interruptions in the instal-

    lation's supply than when the fault cur-

    rent is lower than In

    .

    previous graph, which indicates that the

    current is less dangerous.See the table

    attached, in accordance with IEC 479-2/

    UNE 20-572-93, where a fault current

    of, for example, 45 mA at 500 Hz has

    the same effect as a fault current of 30

    mA at 50 Hz. In the case of receivers

    with EMI lters, we can consider that

    these inject a high-frequency earthed

    current (>2 kHz) and a low frequency

    current. The use of type A earth leakage

    protection systems is specied in these

    cases.

  • 8/11/2019 Ca_P1_03

    8/42

    .1/2 Earth leakage protectionP

    /2-10

    Inverse curve

    Monitoring protection elements

    Remote control and reset

    The IEC 61008-1Standard allows us to

    incorporate a circuit opening delay for

    the circuit being protected, which will

    depend on the leakage current level.

    Therefore, the greater the fault current,

    the lower the delay.

    Two types of curves are specied, as

    shown on the following table of values:

    } Instantaneous

    } Selective

    The application of these curves to our

    earth leakage systems can be used to

    increase the continuity in the installa-

    tion's power supply and avoid unwantedtrips.

    The leakage current value must be

    available at all times in many applica-

    tions. This information is quite useful for

    the installation's preventive and correc-

    tive maintenance tasks, since we can

    act before triggers are set off.

    For example, if the insulation degree of

    a machine is reduced, the earth leakage

    current increases, and since we have

    the said information, we can implement

    the appropriate corrective actions to

    avoid the trigger from being set off.

    The idea is to integrate the earth leaka-

    ge currents in the installation's energy

    control system, thus controlling an addi-

    tional quantity.

    Depending on the type of product, the

    information can be presented as fo-

    llows:

    } In the earth leakage relay, through

    the display.

    } Through the RS-485 communica-

    tions system.

    } With an auxiliary measurement unit.

    In addition, records and logs of the in-

    sulation behaviour of the installation can

    be taken.

    In the case of earth leakage protection

    systems in installations that require a

    continuous supply of energy, with no

    maintenance staff present, the remotecontrol and reset (or self-reclosing)

    functions are very useful.

    Remote control functions can be carried

    out through communications systems

    (RS-485, Ethernet, etc.), using the Power-

    Studio Scada software. This function cancontrol the status of protection systems

    and perform a set of actions through a

    computer and communications systems.

    Type Instantaneous Selective

    In

    (A) All values > 0,03

    S

    tandardisedoperatingtimevalues(s)

    In

    0,3 0,5

    2 . In

    0,15 0,2

    5 . In

    0,04 0,15

    500 A 0,04 0,15

    Maximum

    t

    Id In

  • 8/11/2019 Ca_P1_03

    9/42

    Earth leakage protection P.1/2

    P1/2-11

    Earth leakage protection systems with self-reclosing

    Given the current efcient personal and

    material protection requirements and

    obligations, and the complexity of some

    installations that require the continuous

    supply of electrical energy with the use

    of overload and earth leakage protection

    systems, CIRCUTOR has developed a

    wide range of units that make safety and

    service continuity compatible.

    Self-reclosing systems are an ideal solu-

    tion for installations that need a constant

    supply of electrical energy, without the

    need for the usual maintenance staff:

    } Rural installations} Refrigeration chambers

    } Public lighting

    } Mobile telephony repeaters

    } Trafc lights

    } Lighting of tunnels

    } ATMs

    } Cable television

    } Etc.

    The type of protection element installed,

    those that can be reclosed and under

    which reclosing conditions must be known

    by all self-reclosing systems.

    Self-reclosing systems act in accord-

    ance with the following:

    } Earth leakage current (earth leakage)

    } Earth leakage current (earth leakage) +

    overload and short-circuit (circuit breaker).

    Elements that form an self-reclosing system

    Earth leakage transformer

    The earth leakage transformer detects

    the earth leakage. It can be built-in on a

    relay or as an external element.

    Self-reclosing relay

    Self-reclosing relays add a series of

    performance features (self-reclosing,

    thermal or overload protection) to the

    proven reliability and security of non-re-

    closing earth leakage protection relays.

    It performs the following functions:

    } Detection of anomalies (earth leak-

    age or overload) through the signal gen-

    erated by the transducer.

    } They analyse the anomaly to see if it

    must generate an alarm, depending on

    the parameters programmed.

    }They also act on power elements,

    which perform the grid load connection-

    disconnection tasks.

    Circuit breaker

    The circuit breaker always interrupts the

    ow of power, which supports the power

    in the line protected and is an external

    element of the relay.

    The circuit breakers that can be asso-

    ciated to self-reclosing relays are as

    follows:

    } Motorized circuit breaker (MT)

    } Contact circuit breaker with remotecontrol (MCB), with a dual circuit break-

    er and contact function (the function of

    the contact is bistable).

    Features of the circuit breaker:

    } Nominal current (in contacts)

    } Nominal current and thermal protec-

    tion curve (in circuit breakers)

    } Features of the control inputs of the

    operational element

    }Circuit-breaking power} Auxiliary NO or NC signalling of the

    circuit breaker's status

    TRANSFORMER

    RELAY

    Treatment of the signal,

    measurement and t rigger

    CIRCUIT BREAKER

    monitored

  • 8/11/2019 Ca_P1_03

    10/42

    .1/2 Earth leakage protectionP

    /2-12

    Parameters related to self-reclosing relays

    Relay status indicator

    The indications are associated to the

    type of protection, distinguishing be-

    tween instantaneous triggers and inter-

    lockings. The indications are sent by the

    relay (LED) and, optionally, by auxiliary

    contacts.

    Another type of visualisation, depending

    on the relay, is the instantaneous trigger

    value and the number of total reclosures.

    Nominal trigger point of protec-

    tions

    Standard values:

    } Earth leakage protection 30 mA - 3 A

    } Overload protection 6 A - 63 A

    Timer (delay)

    Minimum time that the earth leakage

    must last before setting off a relay trig-

    ger.

    Standard values: 20 ms - 1s.

    Relay power supply and tolerance

    Self-reclosing relays need a permanent

    form of auxiliary power supply in order to

    manage the self-reclosing operations.

    } Standardised value: 230 Vac 15 %

    } Optional: 48, 110 or 400 Vac

    Reclosing meter reset time.

    To avoid the accumulation of triggers thatdo not correspond to the same anomaly,

    a reset time is dened for the reclos-

    ing meters, provided that the maximum

    number of reclosures is not exceeded.

    Example: The WRU-25 RArelay has a

    maximum number of reclosures available

    before being pushed to its interlocking.

    In installations with a transient earth leak-

    age fault that lasts 50 seconds, the relay

    is triggered 4 times and reclosed 3 times(8 s + 16 s + 30 s). During the timing of

    the third self-reclosing, the fault disap-

    pears, so that the relay will remain in the

    ON position. This is when the reset timer

    of the reclosing meter will be set off.

    The RESET option starts the relay, reset-

    ting the reclosing meters.

    Local (with the keys) and remote

    test and reset

    Self-reclosing earth leakage relays offer

    the same performance as non-reclosing

    relays. It enables the verication of the

    correct operation of the relay with local

    TEST and RESET functions, using the

    keys on the relay, including remote func-

    tions with specic inputs.

    The RESET option resets the relay and

    the reclosing meters.

    Number of reclosures, distin-

    guished by type and number of

    self-reclosing

    Each relay enables a maximum number

    of reclosures before setting off the in-

    terlocking. The meter will be reset au-

    tomatically if the maximum number of

    reclosures is not exceeded within a pre-

    established period of time (reset time of

    reclosing meters).

    This number will be different, in accord-

    ance with the type of self-reclosing.

    Output relay

    } Number of relays

    } With interlocking

    } NO or NC Output contact

    Time between reclosures

    Time the relay takes between the trigger

    and the self-reclosing. It can be linear or

    exponential.

  • 8/11/2019 Ca_P1_03

    11/42

    .1Industrial earth leakage protection P

    P1-13

    Product selection table

    Equipment External toroidal Internal toroidal No. of outputs Indications Communications In(A) Page

    RG1

    M16

    RGE/RGE-R Type WG

    - 1 LEDs -Dependingon the type0.03 ... 5 A

    18

    RGU-10/

    Type WG

    - 1 + pre-alarm DisplayOnly for typeRGU-10 C

    0.03 ... 3 A0.3 ... 30 A 20

    CBS-4/

    Type WG

    - 4 + pre-alarm DisplayOnly for type

    CBS-4 C0.03 ... 3 A0.3 ... 30 A 22

    CBS-8

    Type WG-WGP

    - 8 + pre-alarm Display Yes0.03 ... 6.3 A0.3 ... 63 A 24

    RN1M 28

    RN/RN-R

    Type WN

    - 1 LEDs -Depending on thetype 0.03 ... 5 A 30

    RN-10

    Type WN

    - 1 + pre-alarm LEDs - 0.03 ... 3 A 32

    WRU-10

    -Dependingon the type25 - 35 mm

    1 LEDs - 0.03 ... 3 A 34

    WGBU/

    - 35 ... 210 mm 1 LEDs - 0.03 ... 3 A 38

    WRN-22

    - 22 mm 1 LEDs -0.01 A

    0.03 A0.3 A 41

  • 8/11/2019 Ca_P1_03

    12/42

    .1 Industrial earth leakage protectionP

    -14

  • 8/11/2019 Ca_P1_03

    13/42

    .1Industrial earth leakage protection P

    P1-15

    Useful diameter(mm)

    Weight(g) I

    n(A) Type Code

    20 76 acc. relay WGS-20 P10131

    30 95 acc. relay WGS-30 P10132

    35 181 acc. relay WG-35 P10111

    70 274 acc. relay WG-70 P10112

    105 545 acc. relay WG-105 P10113

    140 1 222 acc. relay WG-140 P10114

    210 2 040 acc. relay WG-210 P10115

    70 x 175 2 400 acc. relay WG-70x175 P10116

    115 x 305 5 450 acc. relay WG-115x305 P10117

    150 x 350 7 400 acc. relay WG-150x350 P10118

    200 x 500 13 400 acc. relay WG-200x500 P10119

    References

    WG Series Earth Leakage transformers

    WG

    WGS Dimensions

    WG Dimensions

    Type A B C D E

    WG-35 100 79 26 48,5 35

    WG-70 130 110 32 66 70

    WG-105 170 146 38 94 105

    WG-140 220 196 48,5 123 140

    WG-210 299 284 69 161 210

    Type A B C D E F G H I

    WG-70X175 70 175 225 85 22 46 261 176 7,5

    WG-115X305 115 305 360 116 25 55 402 240 8

    WG-150X350 150 350 415 140 28 55 460 285 8

    Type A B C D E F G H I

    WG-200X500 200 500 - 140 - 62 585 285 -

    WGS-20

    WGS-30

    WG Series

    Description

    The earth leakage transformers of the WGSeries have been designed

    to work with the relays of the WGSeries. The sensitivity (trigger current)

    of the transformer-relay set is established by the associated relay.

  • 8/11/2019 Ca_P1_03

    14/42

    .1/2 Earth leakage protectionP

    1-16

    Electronic earth leakage relay with externaltransformer of the WG Series

    RG1M

    Proteccin

    Class A superimmunized

    Measurement True root mean square (TRMS)

    Sensitivity 30 or 300 mA

    Delay 20 ms

    Earth leakage transformer External WGSeries

    Test and Reset With built-in buttons, T & R

    Remote Control External Test Option

    Associated circuit breakerContactor or automatic circuit breaker using a coiltrigger

    LED indicator Power supply voltage Leakage trigger Disconnection of external transformer

    Circuit breaker controlThrough a NO/NC switched relay, dependingon the connection with the circuit breaker

    Features

    Auxiliary power supply 230 Vac ( 20 %) 50 / 60 Hz

    Output contacts 250 Vac, 6 A

    Operating temperature -10 ... +65 C

    Construction f eatures

    Fixing DIN Rail 46277 (EN 50022)

    Dimensions 1 module

    Weight 85 g

    Degree of protection IP 20 terminals

    Standards

    IEC 60947-2, IEC 60755, IEC 62020, IEC 61008

    Application

    The RG1M relays combined with the WG

    transformer provides complete differential

    protection, both on single-phase and three-

    phase lines.

    FeaturesDescription

    WG series electronic differential protection

    relay for connection to external WG/WGSse-

    ries toroidal transformers

    } These are highly reliable electronic relays

    with the option of a xed or adjustable sensi-

    tivity and delay

    } Measurement using true root mean squa-

    re (TRMS) value

    } DIN 46277 (En50022) Rail mounting

    } Reduced one module size.

    } LED status indication.

    y Power ON LED.

    y Leakage led ON. Tripped relay.

    y Power LED ashing and leakage LED

    ON. Detection of a transformer continuity

    fault

    WG Series

  • 8/11/2019 Ca_P1_03

    15/42

    Earth leakage protection P.1/2

    P1-17

    Size Attachment In(A) Delay Type Code

    1 modules DIN rail 0.03 0.02 s RG1M-0.03 P12204

    1 modules DIN rail 0.3 0.02 s RG1M-0.3 P12214

    References

    Dimensions

    Connections

    Electronic earth leakage relay with externaltransformer of the WG Series

    RG1M

    WG Series

    66 mm

    72 mm 17.5 mm

    45mm

    64mm

    90mm

    TypeWG

    1S11S2

    7 8

    1 2

    3 4

    5 6

    RG1M

    230V;5A

    50/60 Hz230 V20%

    Test / Reset

    NL1 L2 L3

    TypeWG

    1S11S2

    7 8

    1 2

    3 4

    5 6

    RG1M

    230V;5A

    50/60 Hz230 V20%

    Test / Reset

    NL1L2 L3

    - Rearme manual.Disparo por BOBINA DE MNIMA

    CARGA

    Disparo por BOBINA DE EMISIN

    CARGA

    - Rearme manual.

  • 8/11/2019 Ca_P1_03

    16/42

    .1 Industrial earth leakage protectionP

    -18

    Electronic earth leakage relay with externaltransformer of the WG Series

    RGE/ RGE-R

    Protection

    Class A superimmunized

    Measurement True root mean square (TRMS)

    Sensitivity0.03 A / 0.3 A / 0.5 A / 0.03 ... 3

    A (R1) / 0.03 ... 5 A (R)

    Delay 0.02 / 0.02 ... 1 s (R1) / 0.02 ... 5 s (R)

    Earth leakage transformer External, TRANSFORMERS WG

    Test and Reset With built-in buttons, T & R

    Remote Control External Test Option

    Associated circuit breaker Contact or Circuit breaker + trigger coil

    LED indicator Power supply voltage Trip due to leakageDisconnection of theexternal transformerPre-alarm (R-R1)

    Display View -

    Remote signaling -

    Circuit breaker controlThrough an NO/NC switched relay, dependingon the connection with the circuit breaker

    Features

    Auxiliary power supply230 Vac ( 20 %) 50 / 60 Hz(other values on demand)

    Output contacts 250 Vac, 6 AOperating temperature -10 ... +50 C

    Construction f eatures

    Fixing DIN Rail 46277 (EN 50022)

    Dimensions 2 modules

    Weight 163 g

    Degree of protection IP 20 Terminals, IP 41 back panel

    Standards

    IEC 664, VDE 0110, IEC 801, UL 94, IEC 348, IEC 571-1, EN 61000-6-3, 61000-6-1, 61010-1Application

    The relays of the RGEseries and the trans-

    former of the WG series enable a full earth

    leakage protection for both single and three-phase lines. They guarantee maximum se-

    curity and continuity of the electrical service,

    avoiding unwanted tripping.

    FeaturesDescription

    Electronic earth leakage protection relay,

    used to connect to the earth leakage trans-

    formers WG Series

    } These electronic relays offer a high reli-

    ability, with the option of a xed or adjustable

    sensitivity and delay

    } Type A relay with high frequency current

    ltering and high immunity. Monitoring of the

    true root mean square (TRMS)

    } Assembly on DIN rail 46277

    } Reduced size: 2 modules

    } LED indicators:

    y Permanently lit leak indicator

    y LED: Trigger relay

    y Flashing power LED and lit leak LED:

    detection of faults in the transformer's con-

    tinuity

    y Flashing leak LED indicator (only RGE-R

    and RGE-R1): Leak with a value under the

    value selected

    y 1 ash every 2 s: 25 ... 50 % of the leak-

    age current

    y 1 ash every 1 s: 50 ... 75 %

    y 2 ashes every 1 s: 75 ...

  • 8/11/2019 Ca_P1_03

    17/42

    .1Industrial earth leakage protection P

    P1-19

    Size Fixing In(A) Delay Type Code

    2 modules DIN rail 0,03 0.02 s RGE-0.03 P12201

    2 modules DIN rail 0,3 0.02 s RGE-0.3 P12211

    2 modules DIN rail 0,03 ... 3 0.02 ... 1 s RGE-R1 P12231

    2 modules DIN rail 0,03 ... 5 0.02 ... 5 s RGE-R P12232

    References

    Dimensions

    Connections

    Shunt coil tripping Undervoltage coil tripping

    Electronic earth leakage relay with externaltransformer of the WG Series

    RGE / RGE-R

    WG Series

    EXTERNAL RESET

    SHUNT

    COIL

    LOAD

    I

    EXTERNAL RESET

    I

    LOAD

    UNDERVOLTAGE

    COIL

  • 8/11/2019 Ca_P1_03

    18/42

    .1 Industrial earth leakage protectionP

    -20

    Electronic earth leakage relay with externaltransformer of the WG Series

    RGU-10/ RGU-10 C

    Protection

    Class A superimmunized

    Measurement True root mean square (TRMS)

    Sensitivity0.03 ... 3 A0.03 ... 30 A(PROGRAMMING)

    DelayTime dened: 0,02 ... 10 sInverse curve: Instantaneous or selective

    Earth leakage transformer External, TRANSFORMERS WGTest and Reset With built-in buttons, T & R

    Remote Control External Test Option

    Associated circuit breaker Contact or Circuit breaker + trigger coil

    LED indicator

    Power supply voltage Trip due to leakage Disconnection of the external transformer Pre-alarm

    Display View

    Current trip (red display when triggered) Programming parameters Instantaneous leakage current Disconnection of the external transformer

    Remote signaling Pre-alarm Display of parameters with RS-485communications (RGU-10 C)

    Circuit breaker controlThrough an NO/NC switched relay, dependingon the connection with the circuit breaker

    Features

    Auxiliary power supply230 Vac ( 20 %) 50 / 60 Hz(other values on demand)

    Output contacts 250 Vac, 6 A

    Operating temperature -10 ... +50 C

    Construction f eatures

    Fixing DIN Rail 46277 (EN 50022)

    Dimensions 3 modules

    Weight 236 g

    Degree of protection IP 20 Terminals, IP 41 back panel

    Standards

    IEC 61008-1, IEC 755, IEC 255-5

    Application

    The RGU-10 relays associated to the trans-

    formers of the WG series allow an smart

    earth leakage protection. Their design fea-

    tures guarantee maximum security and con-

    tinuity of the electrical service, avoiding un-

    wanted tripping.

    Showing the value of the leak instantane-

    ously on the display with the pre-alarm in-

    dications provides the information about the

    state of lines being protected, thus allowing

    the implementation of an adequate preven-

    tive maintenance approach.

    In addition, version RGU-10 Cwith RS-485

    communications is used with the Power Stu-

    dio software, which allows the centralisedsupervision of the system in real time, with a

    record log that can be analysed later on.

    FeaturesDescription

    Electronic earth leakage protection relay,

    used to connect to the earth leakage trans-

    formers WG Series

    } Superimmunized Type A relay with high

    frequency current ltering and high immunity

    } Monitoring of the true root mean square

    (TRMS)

    } Display of data on the screenTwo inde-

    pendent programmable outputs (main and

    pre-alarm)

    } External input for remote control functions

    ( 230 Vac).

    WG Series

  • 8/11/2019 Ca_P1_03

    19/42

    .1Industrial earth leakage protection P

    P1-21

    Size Communications In(A) Delay Type Code

    3 modules -0.03 ... 3 A0.03 ... 30 A(PROGRAMMING)

    0.02...10 s, INS, SEL RGU-10 P11941

    3 modules RS-4850.03 ... 3 A0.03 ... 30 A(PROGRAMMING)

    0.02...10 s, INS, SEL RGU-10 C P11944

    References

    Dimensions

    Connections

    Electronic earth leakage relay with externaltransformer of the WG Series

    RGU-10 / RGU-10 C

    WG Series

    Shunt coil Undervoltage coil

  • 8/11/2019 Ca_P1_03

    20/42

    .1 Industrial earth leakage protectionP

    -22

    Earth leakage monitoring and signaling unitof the external transformer of the WG Series

    CBS-4/ CBS-4 C

    Protection

    No. of protections 4

    Class A superimmunized

    Measurement True root mean square (TRMS)

    Sensitivity 0.03 A ... 30 A

    DelayTime dened: 0,02 ... 10 sInverse curve: instantaneous or selective

    Earth leakage transformer External, TRANSFORMERS WG/WGP

    Test and Reset With built-in buttons, T & R

    Associated circuit breaker Contact or Circuit breaker + trigger coil

    Self-reclosing

    No. of reclosures 0 Programming option ... 10

    Time between reclosures 0 Programming option ... 900 s

    Partial counter reset time Double the reclosing time

    LED indicator

    Power supply voltage Leakage trip Pre-alarm Interlocked earth leakage self-reclosing

    Display View

    Current trip (red display when triggered) Instantaneous leak level indicator in each channel Parameter programming

    State of the self-reclosing- Disconnected externaltrans. indicator- Automatic self-reclosing enabled

    Features

    Auxiliary power supply 230 Vac ( 20 %) 50 ... 60 Hz

    Output contacts 250 Vac, 5 A

    Operating temperature -10 ... +50 C

    Construction f eatures

    Fixing DIN Rail 46277 (EN 50022)

    Dimensions 3 modules

    Weight 236 g

    Degree of protection IP 20 Terminals, IP 41 back panel

    Standards

    IEC 664, VDE 0110, IEC 801, UL 94, IEC 348, IEC 571-1, EN 61000-6-3, 61000-6-1, 61010-1

    Application

    FeaturesDescription

    } Unit equivalent to 4 earth leakage protec-

    tion networks. 4 independent programmable

    relays available

    } Four inputs to connect the external toroidal

    transformers of the WG

    } Superimmunized Type A relay with high

    frequency current ltering and high immunity.

    Monitoring in true root mean square (TRMS)

    } Reduced size, with 3 modules

    } 5 independent programmable outputs

    (4 earth leakage trip relays and 1 pre-alarm

    trip).

    The CBS-4earth leakage unit associated to

    the transformers of the WGSeries allows an

    smart earth leakage protection. Its design

    features guarantee maximum security and

    continuity of the electrical service, avoiding

    unwanted tripping.

    Showing the value of the leak instantane-

    ously on the display with the pre-alarm in-

    dications provides the information about the

    state of lines being protected, thus allowing

    the implementation of an adequate preven-

    tive maintenance approach.

    In addition, version CBS-4 C with RS-485

    communications is used with the PowerStu-dio software, which allows the centralised

    supervision of the system in real time, with a

    record log that can be analysed later on.

    WG Series

  • 8/11/2019 Ca_P1_03

    21/42

    .1Industrial earth leakage protection P

    P1-23

    Size Communications No. of Relays In(A) Type Code

    3 modules - 4 0.03 ... 30 s CBS-4 P12711

    3 modules RS-485 4 0.03 ... 30 s CBS-4 C P12712

    References

    Dimensions

    Connections

    Earth leakage monitoring and signaling unitof the external transformer of the WG Series

    CBS-4 / CBS-4 C

    WG Series

  • 8/11/2019 Ca_P1_03

    22/42

    .1 Industrial earth leakage protectionP

    -24

    Earth leakage monitoring and signaling unitof the external transformer of the WG / WGPSeries

    CBS-8

    Protection

    No. of protections 8

    Class A superimmunized

    Measurement True root mean square (TRMS)

    Sensitivity0.03 A ... 6.3 A external transformers WG/WGS0.03 A ... 63 A external transformers WGP/WGSP

    DelayTime dened: 0,02 ... 10 sInverse curve: instantaneous or selective

    Earth leakage transformer External, TRANSFORMERS WG/WGP

    Test and Reset With built-in buttons, T & R

    Associated circuit breaker Contact or Circuit breaker + trigger coil

    Self-reclosing

    No. of reclosures 0 Programming option ... 10

    Time between reclosures 0 Programming option ... 900 s

    Partial counter reset time Double the reclosing time

    LED indicator

    Power supply voltage Leakage trip Pre-alarm Interlocked earth leakage reclosing Automatic self-reclosing enabled

    Display View

    Instantaneous leak level indicator in each channel

    Parameter programming Self-reclosing status

    Features

    Auxiliary power supply 230 Vac ( 20 %) 50 ... 60 Hz

    Output contacts 250 Vac, 5 A

    Operating temperature -10 ... +50 C

    Construction features

    Fixing DIN Rail 46277 (EN 50022)

    Dimensions 8 modules

    Weight 609 g

    Degree of protection IP 20 Terminals, IP 41 back panel

    Standards

    IEC 664, VDE 0110, IEC 801, UL 94, IEC 348, IEC 571-1, EN 61000-6-3, 61000-6-1, 61010-1

    Application

    FeaturesDescription

    } Unit equivalent to 8 earth leakage protec-

    tion networks. 8 independent programmable

    relays available

    } 8 inputs to connect the external toroidal

    transformers of the WG /WGP

    } Superimmunized Type A relay with high

    frequency current ltering and high immunity.

    Monitoring in true root mean square (TRMS)

    } Size adapted for 8 modules

    } 9 independent programmable outputs

    (8 earth leakage trip relays and 1 pre-alarm

    trip).

    The CBS-8earth leakage station associated

    to the transformers of the WG / WGPSeries

    allows an smart earth leakage protection. Its

    design features guarantee maximum security

    and continuity of the electrical service, avoid-

    ing unwanted tripping.

    Showing the value of the leak instantane-

    ously on the display with the pre-alarm in-

    dications provides the information about the

    state of lines being protected, thus allowing

    the implementation of an adequate preven-

    tive maintenance approach.

    In addition, RS-485 communications are

    used with the Power Studio software, whichallows the centralised supervision of the sys-

    tem in real time, with a record log that can be

    analysed later on.

    WG Series

  • 8/11/2019 Ca_P1_03

    23/42

    .1Industrial earth leakage protection P

    P1-25

    References

    Dimensions

    Connections

    Earth leakage monitoring and signaling unitof the external transformer of the WG Series

    CBS-8

    WG Series

    45

    110

    140 70

    Size Communications No. of Relays In(A) Type Code

    8 modules RS-485 8 0.03 ... 63 A CBS-8(*) P12811

    (*) In the case of the 0.3 ... 63 A scale, use earth leakage transformers of the WGP/ WGSP

  • 8/11/2019 Ca_P1_03

    24/42

    .1 Industrial earth leakage protectionP

    -26

    References

    Earth leakage Transformers of the WGPSeries (only for CBS-8)

    WGP

    WGSP Dimensions

    WGP Dimensions

    Type A B C D E

    WGP-35 100 79 26 48,5 35

    WGP-70 130 110 32 66 70

    WGP-105 170 146 38 94 105

    WGP-140 220 196 48,5 123 140

    WGP-210 299 284 69 161 210

    Type A B C D E F G H I

    WGP-70X175 70 175 225 85 22 46 261 176 7,5

    WGP-115X305 115 305 360 116 25 55 402 240 8

    WGP-150X350 150 350 415 140 28 55 460 285 8

    WGSP-20

    WGSP-30

    Useful diameter(mm) Weight (g) I

    n(A) Type Code

    20 76 0,3 ... 63 WGSP-20 P10141

    30 95 0,3 ... 63 WGSP-30 P10142

    35 181 0,3 ... 63 WGP-35 P10121

    70 274 0,3 ... 63 WGP-70 P10122

    105 545 0,3 ... 63 WGP-105 P10123

    140 1 222 0,3 ... 63 WGP-140 P10124

    210 2 040 0,3 ... 63 WGP-210 P10125

    70 x 175 2 400 0,3 ... 63 WGP-70x175 P10126

    115 x 305 5 450 0,3 ... 63 WGP-115x305 P10127

    150 x 350 7 400 0,3 ... 63 WGP-150x350 P10128

    WG Series

    Description

    The earth leakage transformers of the WGP Series have been de-

    signed to work only with the CBS-8relay unit and a sensitivity of 0.3 ...

    63 A. These transformers have a 1/5000 ratio.

  • 8/11/2019 Ca_P1_03

    25/42

    .1Industrial earth leakage protection P

    P1-27

    Usefuldiameter(mm)

    Weight(g) I

    n(A) Type Code

    20 82 acc. relay WNS-20 P10221

    30 100 acc. relay WNS-30 P10222

    35 148 acc. relay WN-35 P10211

    70 281 acc. relay WN-70 P10212

    105 433 acc. relay WN-105 P10213

    140 574 acc. relay WN-140 P10214

    210 1 201 acc. relay WN-210 P10215

    References

    WN Series Earth leakage transformers

    WN

    WNS DimensionsWN Dimensions

    Type A B C D E

    WN-35 100 79 26 48,5 35

    WN-70 130 110 32 66 70

    WN-105 170 146 38 94 105

    WN-140 220 196 48,5 123 140

    WN-210 299 284 69 161 210

    WNS-20

    WNS-30

    WN Series

    Description

    The earth leakage transformers of the WNSeries have been designed

    to work with the relays of the WNSeries.

    The sensitivity (trigger current) of the transformer-relay set is estab-

    lished by the associated relay.

  • 8/11/2019 Ca_P1_03

    26/42

    .1/2 Earth leakage protectionP

    1-28

    Electronic earth leakage relay with externaltransformer of the WN Series

    RN1M

    Application

    The RN1Mrelays combined with the WNtrans-

    former provides complete differential protection,

    both on single-phase and three-phase lines.

    FeaturesDescription

    WN series electronic differential protection

    relay for connection to external WN/WNSse-

    ries toroidal transformers

    } These are highly reliable electronic relays

    with the option of a xed or adjustable sensi-

    tivity and delay

    } Measurement using true root mean squa-

    re (TRMS) value

    } DIN 46277 (En50022) Rail mounting

    } Reduced one module size.

    } LED status indication.

    y Power ON LED.

    y Leakage led ON. Tripped relay.

    y Power LED ashing and leakage LED

    ON. Detection of a transformer continuity

    fault

    Protection

    Class A superimmunized

    Measurement True root mean square (TRMS)

    Sensitivity 30 or 300 mA

    Delay 20 ms

    Earth leakage transformer External WNSeries

    Test and Reset With built-in buttons, T & R

    Remote Control External Test Option

    Associated circuit breakerContactor or automatic circuit breaker using a coiltrigger

    LED indicator Power supply voltage Leakage trigger Disconnection of external transformer

    Circuit breaker controlThrough a NO/NC switched relay, dependingon the connection with the circuit breaker

    Features

    Auxiliary power supply 230 V c.a. ( 20 %) 50 / 60 Hz

    Output contacts 250 V c.a., 6 A

    Operating temperature -10 ... +65 C

    Construction f eatures

    Fixing DIN Rail 46277 (EN 50022)

    Dimensions 1 module

    Weight 85 g

    Degree of protection IP 20 terminals

    Standards

    IEC 60947-2, IEC 60755, IEC 62020, IEC 61008

    WN Series

  • 8/11/2019 Ca_P1_03

    27/42

    Earth leakage protection P.1/2

    P1-29

    Size Attachment In(A) Delay Type Code

    1 modules DIN rail 0,03 0,02 s RN1M-0,03 P12104

    1 modules DIN rail 0,3 0,02 s RN1M-0,3 P12114

    References

    Dimensions

    Connections

    Bobina de emisin

    Bobina mnima

    Electronic earth leakage relay with externaltransformer of the WN Series

    RN1M

    WN Series

    66 mm

    72 mm 17.5 mm

    45mm

    64mm

    90mm

    TypeWN

    S1

    S2

    7 8

    1 2

    3 4

    5 6

    RN1M

    230V,5A

    50/60Hz230V20%

    Test / Reset

    NL1 L2 L3

    TypeWN

    S1

    S2

    7 8

    1 2

    3 4

    5 6

    RN1M

    230V,5A

    50/60Hz230V20%

    Test / Reset

    NL1L2 L3

    Disparo por BOBINA DE MNIMA- Rearme manual.

    CARGA

    - Rearme manual.Disparo por BOBINA DE EMISIN

    CARGA

  • 8/11/2019 Ca_P1_03

    28/42

    .1 Industrial earth leakage protectionP

    -30

    Electronic earth leakage relay with externaltransformer of the WN Series

    RN/ RN-R

    Application

    The relays of the RN series and the trans-

    former of the WN series enable a full earth

    leakage protection for both single and three-

    phase lines.

    FeaturesDescription

    } Electronic earth leakage protection relay,

    used to connect the transformers of the WN

    / WNS Series

    } These electronic relays offer a high relia-

    bility, with the option of a xed or adjustable

    sensitivity and delay

    } Monitoring of the true root mean square

    (TRMS)

    } Assembly on DIN rail 46277 (EN 50022)

    } Reduced size, with 2 modules

    } LED status indicator:

    y Permanently lit leak LED: Tripped relay.

    y Flashing Power LED and lit leak LED:

    Detection of a continuity fault in the trans-

    former.

    y Flashing leak indicator LED (only RN-R

    and RN-R1): Leak with a value that is lower

    than the value selected.

    Protection

    Class A immunised

    Measurement True root mean square (TRMS)

    Sensitivity0.03 A / 0.3 A / 0.5 A / 0.03 ... 3 A (R1) /0.03 ... 5 A (R)

    Delay 0.02 / 0.02 ... 1 s (R1) / 0.02 ... 5 s (R)

    Earth leakage transformer External, TRANSFORMERS WN

    Test and Reset With built-in buttons, T & R

    Remote Control External Test Option

    Associated circuit breaker Contact or Circuit breaker + trigger coil

    LED indicator

    Power supply voltage Trip due to leakage Disconnection of the external transformer Pre-alarm (R-R1)

    Circuit breaker controlThrough an NO/NC switched relay, dependingon the connection with the circuit breaker

    Remote Control External Test Option

    Features

    Auxiliary power supply 230 Vac ( 20 %) 50 / 60 Hz

    Output contacts 250 Vac, 6 A

    Operating temperature -10 ... +50 CConstruction f eatures

    Fixing DIN Rail 46277 (EN 50022)

    Dimensions 2 modules

    Weight 163 g

    Degree of protection IP 20 Terminals, IP 41 back panel

    Standards

    IEC 61008-1, IEC 755, IEC 255-5

    WN Series

  • 8/11/2019 Ca_P1_03

    29/42

    .1Industrial earth leakage protection P

    P1-31

    Size Indicator In(A) Delay Type Code

    2 modules LED 0,03 0.02 s RN-0.03 P12101

    2 modules LED 0,3 0.02 s RN-0.3 P12111

    2 modules LED 0,03 ... 3 0.02 ... 1 s RN-R1 P12131

    2 modules LED 0,03 ... 5 0.02 ... 5 s RN-R P12132

    References

    Dimensions

    Connections

    Shunt coil Undervoltage coil

    Electronic earth leakage relay with externaltransformer of the WN Series

    RN / RN-R

    WN Series

    EXTERNAL RESET

    SHUNT

    COIL

    LOAD

    EXTERNAL RESET

    LOAD

    UNDERVOLTAGE

    COIL

  • 8/11/2019 Ca_P1_03

    30/42

    .1 Industrial earth leakage protectionP

    -32

    Electronic earth leakage relay with externaltransformer of the WN Series

    RN-10

    Protection

    Class A superimmunized

    Measurement True root mean square (TRMS)

    Sensitivity0.03 ... 3 A(PROGRAMMING)

    DelayTime dened: 0,02 ... 1 sInverse curve: Instantaneous or selective

    Earth leakage transformer External, TRANSFORMERS WN

    Test and Reset With built-in buttons, T & R

    Remote Control External Test Option

    Associated circuit breaker Contact or Circuit breaker + trigger coil

    LED indicator

    Power supply voltage Trip due to leakage Disconnection of the external transformer Pre-alarm

    Display View

    Current trip (red display when triggered) Programming parameters Instantaneous leakage current Disconnection of the external transformer

    Remote signaling Pre-alarm Display of parameters with RS-485 communications

    Circuit breaker controlThrough an NO/NC switched relay, depending

    on the connection with the circuit breakerFeatures

    Auxiliary power supply230 Vac ( 20 %) 50 / 60 Hz(other values on demand)

    Output contacts 250 Vac, 6 A

    Operating temperature -10 ... +50 C

    Construction f eatures

    Fixing DIN Rail 46277 (EN 50022)

    Dimensions 3 modules

    Weight 236 g

    Degree of protection IP 20 Terminals, IP 41 back panel

    Standards

    IEC 664, VDE 0110, IEC 801, UL 94, IEC 348, IEC 571-1, EN 61000-6-3, 61000-6-1, 61010-1

    Application

    The RN-10 relays associated to the trans-

    formers of the WN series allow an smart

    earth leakage protection. Their design fea-

    tures guarantee maximum security and con-

    tinuity of the electrical service, avoiding un-

    wanted tripping.

    The instantaneous leakage value is shown

    on the display with the pre-alarm indicators,providing all information required about the

    status of lines being protected, as required

    for the preventive maintenance operations.

    FeaturesDescription

    Electronic earth leakage protection relay s,

    used to connect the transformers of the WN

    / WNSSeries

    } Superimmunized Type A relay with high

    frequency current ltering and high immunity.

    Monitoring in true root mean square (TRMS)

    } Visualization of data on the display

    } Sensitivity can be programmed between

    30 mA and 3 A

    } Adjustable delay: instantaneous, selective

    or timed, up to 1 s

    } Two independent programmable outputs

    (main and pre-alarm relay)

    } External input for remote control functions

    (230 Vac)

    } Automatic verication of the connection

    and status of the external transformer with an

    inductive test

    } Reduced size, with 3 modules

    WN Series

  • 8/11/2019 Ca_P1_03

    31/42

    .1Industrial earth leakage protection P

    P1-33

    References

    Dimensions

    Connections

    Electronic earth leakage relay with externaltransformer of the WN Series

    RN-10

    Size Indicator In(A) Delay Type Code

    3 modules LED 0,03 ... 3 0.02 ... 1 s RN-10 P12140

    WN Series

    Shunt coil Undervoltage coil

  • 8/11/2019 Ca_P1_03

    32/42

    .1/2 Earth leakage protectionP

    1-34

    Rel diferencial con transformadorincorporado con display (tipo A)

    WRU-10

    Proteccin

    Clase A superinmunizada

    Medida Verdadero valor ecaz, TRMS

    Sensibilidad PROGRAMABLE 0,03 ... 3 A, ampliable hasta 30 A por SETUP

    Retardo PROGRAMABLETiempo denido: 0,02 ...1 s, ampliablehasta 10s por SETUP. Curva inversa:INStantnea / SELectiva. (IEC 60947-2)

    Test y Reset Mediante pulsadores T y R

    Control RemotoPosibilidad de TEST externo, disparo por entrada librede tensin.

    Elemento de corte asociado Contactor o interruptor automtico con bobina de disparo

    Indicacin por LED/DISPLAY

    - Tensin de alimentacin- Disparo por fuga- Prealarma

    - Parmetros de proteccin- Lectura corriente de fuga/disparo.- Estados de TEST y disparoexterno.

    Control de elemento de corteRel de contacto conmutado NA/NC segn elementode corte

    Caractersticas elctricas

    Alimentacin auxiliar 230 V c.a. ( 30 %) 50 / 60 Hz

    Contactos salida disparo/prealarma 250 V c.a., 5 A / 230 V c.a., 250 mA

    Temperatura de uso -20 ...+70 CCaractersticas mecnicas

    Fijacin Carril DIN 46722 (EN 50022)

    Dimensiones 3 mdulos

    Peso 275 g

    Grado de proteccin IP 20, transcuadro IP 41

    Normas

    IEC 60947-2, IEC 60755, IEC 62020, IEC 61008

    Application

    FeaturesDescription

    Electronic differential protection relay with built-

    in 28 mm transformer, constituting one unit.

    } Type A high-insulation, with high-frequency

    current lter and high insulation. Monitoring

    using true root mean square.

    } Display with LEDs and display:

    - differential protection settings.

    - protection trigger current.

    - protection status messages, etc.

    } Units with three programmable output con-

    tact relays, one switched and two simple. The

    main relay is for the protection provided by the

    contact or trigger relay of the automatic switch

    while the two others are for the pre-alarm.

    } It also has a voltage input for external trigge-

    ring and re-arming.

    } Assembly on DIN Rail 46277 (EN 50022)

    } Reduced three-module size.

    } Connection by pluggable terminals.

    Los rels WRU-10 permiten una proteccin

    difencial inteligente. Por sus caractersticas de

    diseo aseguran la mxima seguridad t conti-

    nuidad en el servicio elctrico, evitndose dis-

    paros intempestivos.

    El poder visualizar el valor de fuga instantnea

    en el display, conjuntamente con las indicacio-

    nes de prealarma, permite tener informacin

    del estado de las lneas que protegen, y reali-

    zar un buen mantenimiento preventivo.

  • 8/11/2019 Ca_P1_03

    33/42

    Earth leakage protection P.1/2

    P1-35

    References

    Dimensions

    Connections

    WRU-10 WRU-10

    Differential relay with bui lt-in transformer anddisplay (type A)

    WRU-10

    Size Net section (mm) In(A) Delay Type Code

    3 modules 28 0.03 ... 3 A extendibleto 30 A

    0.02 ... 1 s extendible to 10s Curve(Inverse): INS/SEL

    WRU-25P2

  • 8/11/2019 Ca_P1_03

    34/42

    .1 Industrial earth leakage protectionP

    -36

    Earth leakage relay with built-in transformer(type A)

    WRU

    Protection

    Class A superimmunized

    Measurement True root mean square (TRMS)

    Sensitivity 0.03 ... 3 A

    Delay 0.02 ... 1 s

    Earth leakage transformer Internal

    Test and Reset With built-in buttons, T & R

    Remote Control (inputs) External test

    Associated circuit breaker Contact or Circuit breaker + trigger coil

    Relay signaling Power supply voltage Trip due to leakage Pre-alarm

    Remote signaling (outputs)Leak control signal (proportional alternatingvoltage) (only in WRU-25)

    Circuit breaker controlThrough an NO/NC switched relay, dependingon the connection with the circuit breaker

    Features

    Auxiliary power supply 230 Vac ( 20 %) 50 / 60 Hz

    Output contacts 250 Vac, 6 A

    Operating temperature -10 ... +50 CConstruction f eatures

    Fixing DIN rail

    Dimensions 4 modules (WRU-25), 6 modules (WRU-35)

    Weight 228 g (WRU-25), 403 g (WRU-35)

    Degree of protection IP 20 Terminals, IP 41 back panel

    Standards

    IEC 1008, IEC 255-5, UNE 801-2, UNE 801-3, UNE 801-4, UNE 60730-1

    Application

    FeaturesDescription

    Electronic earth leakage protection relay with

    built-in transformer, with a diameter of 25 or

    35 mm , depending on the type, creating a

    single set.

    } Type A relay with high frequency current

    ltering and high immunity. Monitoring in true

    root mean square.

    } The sensitivity can be adjusted to 0.03 ... 3 A

    } The delay in the trigger can be adjusted

    to 0.02 ... 1 s

    } LED indicator of the leak level (% sensi-

    tivity):

    y 1 ash every 2 s: between 25 and 50 %

    y 1 ash every 1 s: between 50 and 75 %

    y 1 ash every 0.5 s: between 75 and 90 %

    } Adjustable to the DIN prole 46277 (EN

    50022)

    The WRU Series allows a reliable and im-

    munised form of earth leakage protection,

    saving installation time. Its assembly is very

    simple, offering an adequate solution for all

    types of single and three-phase installations,

    since it offers compact earth leakage protec-

    tion, with the optional adjustment of the sen-

    sitivity and time.

  • 8/11/2019 Ca_P1_03

    35/42

    .1Industrial earth leakage protection P

    P1-37

    References

    Dimensions

    Connections

    WRU-25 WRU-35

    Earth leakage relay with built-in transformer(type A)

    WRU

    SizeUseful diameter

    (mm) In(A) Delay Type Code

    4 modules 25 0,03 ... 3 0.02 ... 1 s WRU-25 P14011

    6 modules 35 0,03 ... 3 0.02 ... 1 s WRU-35 P14021

    The delay is cancelled in all relays with a sensitivity adjustment of 0.03 A.

    WRU-25

    WRU-35

    1

    1

    22

  • 8/11/2019 Ca_P1_03

    36/42

    .1 Industrial earth leakage protectionP

    -38

    Transformer with built-in earth leakage relay

    WGBU

    Earth leakage Protection

    Class A superimmunized

    Measurement True root mean square (TRMS)

    Sensitivity 0.03 ... 3 A

    Delay 0.02 ... 1 s

    Earth leakage transformer Built-in transformers of the WG

    Test and Reset With built-in buttons, T & R

    Associated circuit breaker Contact or Circuit breaker + trigger coil

    LED indicator Power supply voltage Trip due to leakage Pre-alarm

    Remote Control (inputs) External Test Option

    Circuit breaker controlThrough an NO/NC switched relay, dependingon the connection with the circuit breaker

    Features

    Auxiliary power supply 230 Vac ( 20 %) 50 / 60 Hz

    Output contacts 250 Vac, 6 A

    Operating temperature -10 ... +50 C

    Construction f eatures

    Fixing DIN Panel / Rail

    Dimensions Depending on the type

    Weight Depending on the type

    Degree of protection IP 20 Terminals, IP 41 back panel

    Standards

    IEC 61008-1, IEC 755, IEC 255-5

    Application

    The WGBU series offers a reliable earth

    leakage protection, with simpler cabling and

    savings in the assembly time. In addition, in-

    stallation is very simple, thanks to its compact

    dimensions.

    FeaturesDescription

    The WGBUSeries is a compact earth leak-

    age protection system. It is composed of a

    toroidal transformer with a built-in earth leak-

    age relay.

    } Multi-range electronic relay

    y The sensitivity can be adjusted to 0.03 ... 3 A

    y Trigger delay of 0.02 ... 1 ws, adjustable

    } Type A relay with high frequency current

    ltering and high immunity. Monitoring in true

    root mean square (TRMS).

    } LED indicators:

    y Grid connection LED

    y Pre-alarm and trigger LED: 1 ash every 2

    s, leak between 25 and 50 % of the sensitiv-

    ity selected; 1 ash every 1 s, leak between

    50 and 75 % of the sensitivity selected; 1

    ash every 0.5 s, leak exceeding 75 % of

    the sensitivity selected; permanently lit, trig-

    ger of the earth leakage protection.

  • 8/11/2019 Ca_P1_03

    37/42

    .1Industrial earth leakage protection P

    P1-39

    References

    Dimensions

    Transformer with built-in earth leakage relay

    WGBU

    Weight (g)Useful diameter(mm) I

    n(A) Delay (s) Type Code

    380 35 0,03 ... 3 0,02 ... 1 WGBU-35 P16011

    474 70 0,03 ... 3 0,02 ... 1 WGBU-70 P16012

    744 105 0,03 ... 3 0,02 ... 1 WGBU-105 P16013

    1422 140 0,03 ... 3 0,02 ... 1 WGBU-140 P16014

    2240 210 0,03 ... 3 0,02 ... 1 WGBU-210 P16015

    380 35 0,03 ... 3 0,02 ... 1 WGBU-90-35 P16021

    474 70 0,03 ... 3 0,02 ... 1 WGBU-90-70 P16022

    744 105 0,03 ... 3 0,02 ... 1 WGBU-90-105 P16023

    1422 140 0,03 ... 3 0,02 ... 1 WGBU-90-140 P16024

    2240 210 0,03 ... 3 0,02 ... 1 WGBU-90-210 P16025

    The delay is cancelled in all relays with a sensitivity adjustment of 0.03 A.

    WGBU

    WGBU-90

    Type A1 A2 B C D E

    WGBU-35 (A1) / WGBU-90-35 (A2) 166 100 79 26 48,5 35

    WGBU-70 (A1) / WGBU-90-70 (A2) 196 130 110 332 66 70

    WGBU-105 (A1) / WGBU-90-105 (A2) 236 170 146 38 94 105

    WGBU-140 (A1) / WGBU-90-140 (A2) 286 220 196 48,5 123 140

    WGBU-210 (A1) / WGBU-90-210 (A2) 365 299 284 69 161 210

  • 8/11/2019 Ca_P1_03

    38/42

    .1 Industrial earth leakage protectionP

    -40

    Shunt coil

    Undervoltage coil

    Connections

    Transformer with built-in earth leakage relay

    WGBU

  • 8/11/2019 Ca_P1_03

    39/42

    .1Industrial earth leakage protection P

    P1-41

    Earth leakage relay wi th built-in transformer

    WRN-22

    Protection

    Class A

    Measurement True root mean square (TRMS)

    Sensitivity 0,01 A / 0,03 A / 0,30 A (depending on the type)

    Delay 0.02 s

    Earth leakage transformer Internal

    Test With built-in button, TEST

    Associated circuit breaker Circuit breaker + trigger coil

    Relay signaling Power supply voltage Leakage trigger

    Remote signaling (outputs) -

    Remote Control (inputs) External test

    Circuit breaker control Voltage 230 Vac

    Features

    Auxiliary power supply 230 Vac ( 20 %) 50 / 60 Hz

    Output contacts -

    Operating temperature -10 ... +50 C

    Construction f eatures

    Fixing DIN rail

    Dimensions 3 modules

    Weight 146 g

    Degree of protection IP 20 Terminals, IP 41 back panel

    Standards

    IEC 1008, IEC 255-5, UNE 801-2, UNE 801-3, UNE 801-4, UNE 60730-1

    Application

    The WRN-22 earth leakage protection is a

    very interesting solution for small-scale in-

    stallations with reduced space.

    FeaturesDescription

    The WRN-22relay is an earth leakage relay

    with a built-in earth leakage transformer, with

    a diameter 22 mm

    } DIN 46277 Symmetrical prole coupling

    (EN 50022)

    } The leakage is detected by means of

    sampling the earth leakage intensity and cal-

    culating its true root mean square (TRMS)

    } Detection of the presence of voltage with

    LEDs

    } TEST button.

  • 8/11/2019 Ca_P1_03

    40/42

    .1 Industrial earth leakage protectionP

    -42

    References

    Dimensions

    Connections

    Earth leakage relay wi th built-in transformer

    WRN-22

    SizeUseful diameter

    (mm) In(A) Delay (s) Type Code

    3 modules 22 0,03 0,02 WRN-22-0.03 P14211

    3 modules 22 0,3 0,02 WRN-22-0.3 P14212

    3 modules 22 0,01 0,02 WRN-22-0.01 P14214

  • 8/11/2019 Ca_P1_03

    41/42

    .1Industrial earth leakage protection P

    P1-43

    Relation between products and accessories

    Adaptor p anel PA-TC/WG TT

    Adaptor for 72 x 72 panel Accessory for assembly on DIN rail Core balance shield tube

    M5ZZF1 P19921

    TT-35 P19911

    TT-70 P19912

    TT-105 P19913

    TT-140 P19914

    TT-210 P19915

    WG --

    only for WG-35up to WG-210

    WGP

    --

    only for WGP-35up to WGP-210

    RGU-10

    -- --

    CBS

    only CBS-4-- --

    WN --

    only for WN-35up to WN-210

    RN-10

    -- --

    WGBU

    -- --

  • 8/11/2019 Ca_P1_03

    42/42

    .1 Industrial earth leakage protectionP